Real-time iterative monitoring of radiofrequency ablation tumor therapy with 15O-water PET imaging.
Bao, Ande; Goins, Beth; Dodd, Gerald D; Soundararajan, Anuradha; Santoyo, Cristina; Otto, Randal A; Davis, Michael D; Phillips, William T
2008-10-01
A method that provides real-time image-based monitoring of solid tumor therapy to ensure complete tumor eradication during image-guided interventional therapy would be a valuable tool. The short, 2-min half-life of (15)O makes it possible to perform repeated PET imaging at 20-min intervals at multiple time points before and after image-guided therapy. In this study, (15)O-water PET was evaluated as a tool to provide real-time feedback and iterative image guidance to rapidly monitor the intratumoral coverage of radiofrequency (RF) ablation therapy. Tumor RF ablation therapy was performed on head and neck squamous cell carcinoma (SCC) xenograft tumors (length, approximately 23 mm) in 6 nude rats. The tumor in each animal was ablated with RF (1-cm active size ablation catheter, 70 degrees C for 5 min) twice in 2 separate tumor regions with a 20-min separation. The (15)O-water PET images were acquired before RF ablation and after the first RF and second RF ablations using a small-animal PET scanner. In each PET session, approximately 100 MBq of (15)O-water in 1.0 mL of saline were injected intravenously into each animal. List-mode PET images were acquired for 7 min starting 20 s before injection. PET images were reconstructed by 2-dimensional ordered-subset expectation maximization into single-frame images and dynamic images at 10 s/frame. PET images were displayed and analyzed with software. Pre-RF ablation images demonstrate that (15)O-water accumulates in tumors with (15)O activity reaching peak levels immediately after administration. After RF ablation, the ablated region had almost zero activity, whereas the unablated tumor tissue continued to have a high (15)O-water accumulation. Using image feedback, the RF probe was repositioned to a tumor region with residual (15)O-water uptake and then ablated. The second RF ablation in this new region of the tumor resulted in additional ablation of the solid tumor, with a corresponding decrease in activity on the (15)O-water PET image. (15)O-water PET clearly demonstrated the ablated tumor region, whereas the unablated tumor continued to show high (15)O-water accumulation. (15)O-water imaging shows promise as a tool for on-site, real-time monitoring of image-guided interventional cancer therapy.
Andersen, Julie B; Henning, William S; Lindberg, Ulrich; Ladefoged, Claes N; Højgaard, Liselotte; Greisen, Gorm; Law, Ian
2015-01-01
Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic–ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous 15O-water positron emission tomography (PET) and single TI pulsed arterial spin labeling (ASL) magnetic resonance imaging (MR) on a hybrid PET/MR in seven newborn piglets. Positron emission tomography was performed with IV injections of 20 MBq and 100 MBq 15O-water to confirm CBF reliability at low activity. Cerebral blood flow was quantified using a one-tissue-compartment-model using two input functions: an arterial input function (AIF) or an image-derived input function (IDIF). The mean global CBF (95% CI) PET-AIF, PET-IDIF, and ASL at baseline were 27 (23; 32), 34 (31; 37), and 27 (22; 32) mL/100 g per minute, respectively. At acetazolamide stimulus, PET-AIF, PET-IDIF, and ASL were 64 (55; 74), 76 (70; 83) and 79 (67; 92) mL/100 g per minute, respectively. At baseline, differences between PET-AIF, PET-IDIF, and ASL were 22% (P<0.0001) and −0.7% (P=0.9). At acetazolamide, differences between PET-AIF, PET-IDIF, and ASL were 19% (P=0.001) and 24% (P=0.0003). In conclusion, PET-IDIF overestimated CBF. Injected activity of 20 MBq 15O-water had acceptable concordance with 100 MBq, without compromising image quality. Single TI ASL was questionable for regional CBF measurements. Global ASL CBF and PET CBF were congruent during baseline but not during hyperperfusion. PMID:26058699
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGuire, S; Ponto, L; Menda, Y
Purpose: To compare proliferation and blood flow in pelvic and thoracic bone marrow 1 year after pelvic chemoradiation. Methods: Sixteen pelvic cancer patients were enrolled in an IRB-approved protocol to acquire FLT PET images during radiation therapy simulation (baseline) and 1 year after chemoradiation therapy. Three subjects also had optional O-15 water PET images acquired 1 year after chemoradiation therapy. Baseline FLT PET images were used to create IMRT plans to spare pelvic bone marrow identified as regions with FLT SUV ≥ 2 without compromising PTV coverage or OAR sparing. Marrow VOIs were defined using a 50% maximum pixel valuemore » threshold on baseline FLT PET images (VIEW, PMOD version 3.5) in the sacrum and thoracic spine representing irradiated and non-irradiated regions, respectively. FLT PET and O-15 water PET images acquired 1 year after therapy were co-registered to baseline images (FUSION PMOD) and the same VOIs were used to measure proliferation (FLT SUV) and blood flow (O-15 water uptake). Separate image-based input functions were used for blood flow quantitation in each VOI. Results: Mean 1 year FLT SUV in sacral and thoracic VOIs for were 1.1 ± 0.4 and 6.5 ± 1.7, respectively for N = 16 subjects and were 1.2 ± 0.2 and 5.6 ± 1.6, respectively for N = 3 subjects who also underwent O-15 water imaging. Blood flow measures in equivalent sacral and thoracic marrow regions (N = 3) were 21.3 ± 8.7 and 18.3 ± 4.9 mL/min/100mL respectively. Conclusion: Decreased bone marrow proliferation measured by FLT SUV does not appear to correspond to decreased blood flow as measured by O-15 water PET imaging. Based on this small sample at a single time point, reduced blood supply does not explain reductions in bone marrow proliferative activity 1 year after chemoradiation therapy.« less
Simultaneous water activation and glucose metabolic rate imaging with PET
NASA Astrophysics Data System (ADS)
Verhaeghe, Jeroen; Reader, Andrew J.
2013-02-01
A novel imaging and signal separation strategy is proposed to be able to separate [18F]FDG and multiple [15O]H2O signals from a simultaneously acquired dynamic PET acquisition of the two tracers. The technique is based on the fact that the dynamics of the two tracers are very distinct. By adopting an appropriate bolus injection strategy and by defining tailored sets of basis functions that model either the FDG or water component, it is possible to separate the FDG and water signal. The basis functions are inspired from the spectral analysis description of dynamic PET studies and are defined as the convolution of estimated generating functions (GFs) with a set of decaying exponential functions. The GFs are estimated from the overall measured head curve, while the decaying exponential functions are pre-determined. In this work, the time activity curves (TACs) are modelled post-reconstruction but the model can be incorporated in a global 4D reconstruction strategy. Extensive PET simulation studies are performed considering single [18F]FDG and 6 [15O]H2O bolus injections for a total acquisition time of 75 min. The proposed method is evaluated at multiple noise levels and different parameters were estimated such as [18F]FDG uptake and blood flow estimated from the [15O]H2O component, requiring a full dynamic analysis of the two components, static images of [18F]FDG and the water components as well as [15O]H2O activation. It is shown that the resulting images and parametric values in ROIs are comparable to images obtained from separate imaging, illustrating the feasibility of simultaneous imaging of [18F]FDG and [15O]H2O components. For more information on this article, see medicalphysicsweb.org
Harms, Hendrik Johannes; Tolbod, Lars Poulsen; Hansson, Nils Henrik Stubkjær; Kero, Tanja; Orndahl, Lovisa Holm; Kim, Won Yong; Bjerner, Tomas; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiær, Jørgen; Sörensen, Jens
2015-12-01
The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR). FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p < 0.001 for all). FSV based on (11)C-acetate and (15)O-water correlated highly (r = 0.99, slope = 1.03) with no significant difference between FSV estimates (p = 0.14). FSV can be obtained automatically using dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation.
Fletcher, James W; Logan, Theodore F; Eitel, Jacob A; Mathias, Carla J; Ng, Yen; Lacy, Jeffrey L; Hutchins, Gary D; Green, Mark A
2015-01-01
This study was undertaken to demonstrate the feasibility of whole-body (62)Cu-ethylglyoxal bis(thiosemicarbazonato)copper(II) ((62)Cu-ETS) PET/CT tumor perfusion imaging in patients with metastatic renal carcinoma and to validate (62)Cu-ETS as a quantitative marker of tumor perfusion by direct comparison with (15)O-water perfusion imaging. PET/CT imaging of 10 subjects with stage IV renal cell cancer was performed after intravenous administration of (15)O-water (10-min dynamic list-mode study) with the heart and at least 1 tumor in the PET field of view, followed 10 min later by intravenous (62)Cu-ETS (6-min list-mode study). Whole-body (62)Cu imaging was then performed from 6 to 20 min at 2-3 min/bed position. Blood flow (K1) was quantified with both agents for normal and malignant tissues in the 21.7-cm dynamic field of view. The required arterial input functions were derived from the left atrium and, in the case of (62)Cu-ETS, corrected for partial decomposition of the agent by blood with data from an in vitro analysis using a sample of each patient's blood. This imaging protocol was repeated at an interval of 3-4 wk after initiation of a standard clinical treatment course of the antiangiogenic agent sunitinib. All subjects received the scheduled (62)Cu-ETS doses for the dynamic and subsequent whole-body PET/CT scans, but technical issues resulted in no baseline (15)O-water data for 2 subjects. Direct comparisons of the perfusion estimates for normal tissues and tumor metastases were made in 18 paired baseline and treatment studies (10 subjects; 8 baseline studies, 10 repeated studies during treatment). There was an excellent correlation between the blood flow estimates made with (62)Cu-ETS and (15)O-water for normal tissues (muscle, thyroid, myocardium) and malignant lesions (pulmonary nodules, bone lesions); the regression line was y = 0.85x + 0.15, R(2) = 0.83, for the 88 regions analyzed. (62)Cu-ETS provided high-quality whole-body PET/CT images, and (62)Cu-ETS measures of blood flow were highly and linearly correlated with (15)O-water-derived K1 values (mL(-1) ⋅ min(-1) ⋅ g). This tracer is suitable for use as a PET tracer of tumor perfusion in patients with metastatic renal cell carcinoma. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Agostini, Denis; Roule, Vincent; Nganoa, Catherine; Roth, Nathaniel; Baavour, Raphael; Parienti, Jean-Jacques; Beygui, Farzin; Manrique, Alain
2018-07-01
We assessed the feasibility of myocardial blood flow (MBF) and flow reserve (MFR) estimation using dynamic SPECT with a novel CZT camera in patients with stable CAD, in comparison with 15 O-water PET and fractional flow reserve (FFR). Thirty patients were prospectively included and underwent FFR measurements in the main coronary arteries (LAD, LCx, RCA). A stenosis ≥50% was considered obstructive and a FFR abnormal if ≤0.8. All patients underwent a dynamic rest/stress 99m Tc-sestamibi CZT-SPECT and 15 O-water PET for MBF and MFR calculation. Net retention kinetic modeling was applied to SPECT data to estimate global uptake values, and MBF was derived using Leppo correction. Ischemia by PET and CZT-SPECT was considered present if MFR was lower than 2 and 2.1, respectively. CZT-SPECT yielded higher stress and rest MBF compared to PET for global and LAD and LCx territories, but not in RCA territory. MFR was similar in global and each vessel territory for both modalities. The sensitivity, specificity, accuracy, positive and negative predictive value of CZT-SPECT were, respectively, 83.3, 95.8, 93.3, 100 and 85.7% for the detection of ischemia and 58.3, 84.6, 81.1, 36.8 and 93% for the detection of hemodynamically significant stenosis (FFR ≤ 0.8). Dynamic 99m Tc-sestamibi CZT-SPECT was technically feasible and provided similar MFR compared to 15 O-water PET and high diagnostic value for detecting impaired MFR and abnormal FFR in patients with stable CAD.
Nordström, Jonny; Kero, Tanja; Harms, Hendrik Johannes; Widström, Charles; Flachskampf, Frank A; Sörensen, Jens; Lubberink, Mark
2017-11-14
Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15 O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15 O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B ) 15 O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15 O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. Using V B images, high correlations between PET and MRI ESV (r = 0.89, p < 0.001), EDV (r = 0.85, p < 0.001), SV (r = 0.74, p = 0.006) and LVEF (r = 0.72, p = 0.008) were found for the volume-based method. Correlations for FP images were slightly, but not significantly, lower than those for V B images when compared to MRI. Surface- and count-based methods showed no significant difference compared with the volume-based correlations with MRI. The volume-based method showed the best agreement with MRI with no significant difference on average for EDV and LVEF but with an overestimation of values for ESV (14%, p = 0.005) and SV (18%, p = 0.004) when using V B images. Using FP images, none of the parameters showed a significant difference from MRI. Inter-operator repeatability was excellent for all parameters (ICC > 0.86, p < 0.001). Calculation of LV volumes and LVEF from dynamic 15 O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.
Iwanishi, Katsuhiro; Watabe, Hiroshi; Hayashi, Takuya; Miyake, Yoshinori; Minato, Kotaro; Iida, Hidehiro
2009-06-01
Cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO(2)), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) are quantitatively measured with PET with (15)O gases. Kudomi et al. developed a dual tracer autoradiographic (DARG) protocol that enables the duration of a PET study to be shortened by sequentially administrating (15)O(2) and C(15)O(2) gases. In this protocol, before the sequential PET scan with (15)O(2) and C(15)O(2) gases ((15)O(2)-C(15)O(2) PET scan), a PET scan with C(15)O should be preceded to obtain CBV image. C(15)O has a high affinity for red blood cells and a very slow washout rate, and residual radioactivity from C(15)O might exist during a (15)O(2)-C(15)O(2) PET scan. As the current DARG method assumes no residual C(15)O radioactivity before scanning, we performed computer simulations to evaluate the influence of the residual C(15)O radioactivity on the accuracy of measured CBF and OEF values with DARG method and also proposed a subtraction technique to minimize the error due to the residual C(15)O radioactivity. In the simulation, normal and ischemic conditions were considered. The (15)O(2) and C(15)O(2) PET count curves with the residual C(15)O PET counts were generated by the arterial input function with the residual C(15)O radioactivity. The amounts of residual C(15)O radioactivity were varied by changing the interval between the C(15)O PET scan and (15)O(2)-C(15)O(2) PET scan, and the absolute inhaled radioactivity of the C(15)O gas. Using the simulated input functions and the PET counts, the CBF and OEF were computed by the DARG method. Furthermore, we evaluated a subtraction method that subtracts the influence of the C(15)O gas in the input function and PET counts. Our simulations revealed that the CBF and OEF values were underestimated by the residual C(15)O radioactivity. The magnitude of this underestimation depended on the amount of C(15)O radioactivity and the physiological conditions. This underestimation was corrected by the subtraction method. This study showed the influence of C(15)O radioactivity in DARG protocol, and the magnitude of the influence was affected by several factors, such as the radioactivity of C(15)O, and the physiological condition.
Cardiac PET perfusion tracers: current status and future directions.
Maddahi, Jamshid; Packard, René R S
2014-09-01
PET myocardial perfusion imaging (MPI) is increasingly being used for noninvasive detection and evaluation of coronary artery disease. However, the widespread use of PET MPI has been limited by the shortcomings of the current PET perfusion tracers. The availability of these tracers is limited by the need for an onsite ((15)O water and (13)N ammonia) or nearby ((13)N ammonia) cyclotron or commitment to costly generators ((82)Rb). Owing to the short half-lives, such as 76 seconds for (82)Rb, 2.06 minutes for (15)O water, and 9.96 minutes for (13)N ammonia, their use in conjunction with treadmill exercise stress testing is either not possible ((82)Rb and (15)O water) or not practical ((13)N ammonia). Furthermore, the long positron range of (82)Rb makes image resolution suboptimal and its low myocardial extraction limits its defect resolution. In recent years, development of an (18)F-labeled PET perfusion tracer has gathered considerable interest. The longer half-life of (18)F (109 minutes) would make the tracer available as a unit dose from regional cyclotrons and allow use in conjunction with treadmill exercise testing. Furthermore, the short positron range of (18)F would result in better image resolution. Flurpiridaz F 18 is by far the most thoroughly studied in animal models and is the only (18)F-based PET MPI radiotracer currently undergoing clinical evaluation. Preclinical and clinical experience with Flurpiridaz F 18 demonstrated a high myocardial extraction fraction, high image and defect resolution, high myocardial uptake, slow myocardial clearance, and high myocardial-to-background contrast that was stable over time-important properties of an ideal PET MPI radiotracer. Preclinical data from other (18)F-labeled myocardial perfusion tracers are encouraging. Copyright © 2014. Published by Elsevier Inc.
Ochi, Noriki; Yoshinaga, Keiichiro; Ito, Yoichi M; Tomiyama, Yuuki; Inoue, Mamiko; Nishida, Mutsumi; Manabe, Osamu; Shibuya, Hitoshi; Shimizu, Chikara; Suzuki, Eriko; Fujii, Satoshi; Katoh, Chietsugu; Tamaki, Nagara
2016-10-01
Comprehensive evaluation of endothelium-dependent and endothelium-independent vascular functions in peripheral arteries and coronary arteries in smokers has never been performed previously. Through the use of brachial artery ultrasound and oxygen-15-labeled water positron emission tomography (PET), we sought to investigate peripheral and coronary vascular dysfunctions in smokers. Eight smokers and 10 healthy individuals underwent brachial artery ultrasound at rest, during reactive hyperemia [250mmHg cuff occlusion (flow-mediated dilatation (FMD)], and following sublingual nitroglycerin (NTG) administration. Myocardial blood flow (MBF) was assessed through O-15-labeled water PET at rest, during adenosine triphosphate (ATP) administration, and during a cold pressor test (CPT). Through ultrasound, smokers were shown to have significantly reduced %FMD compared to controls (6.62±2.28% vs. 11.29±2.75%, p=0.0014). As assessed by O-15-labeled water PET, smokers were shown to have a significantly lower CPT response than were controls (21.1±9.5% vs. 50.9±16.9%, p=0.0004). There was no relationship between %FMD and CPT response (r=0.40, p=0.097). Endothelium-independent vascular dilatation was similar for both groups in terms of coronary flow reserve with PET (p=0.19). Smokers tended to have lower %NTG in the brachial artery (p=0.055). Smokers exhibited impaired coronary endothelial function as well as peripheral brachial artery endothelial function. In addition, there was no correlation between PET and ultrasound measurements, possibly implying that while smokers may have systemic vascular endothelial dysfunction, the characteristics of that dysfunction may be different in peripheral arteries and coronary arteries. Copyright © 2016. Published by Elsevier Ltd.
Tomiyama, Yuuki; Manabe, Osamu; Oyama-Manabe, Noriko; Naya, Masanao; Sugimori, Hiroyuki; Hirata, Kenji; Mori, Yuki; Tsutsui, Hiroyuki; Kudo, Kohsuke; Tamaki, Nagara; Katoh, Chietsugu
2015-09-01
To develop and validate a method for quantifying myocardial blood flow (MBF) using dynamic perfusion magnetic resonance imaging (MBFMRI ) at 3.0 Tesla (T) and compare the findings with those of (15) O-water positron emission tomography (MBFPET ). Twenty healthy male volunteers underwent magnetic resonance imaging (MRI) and (15) O-water positron emission tomography (PET) at rest and during adenosine triphosphate infusion. The single-tissue compartment model was used to estimate the inflow rate constant (K1). We estimated the extraction fraction of Gd-DTPA using K1 and MBF values obtained from (15) O-water PET for the first 10 subjects. For validation, we calculated MBFMRI values for the remaining 10 subjects and compared them with the MBFPET values. In addition, we compared MBFMRI values of 10 patients with coronary artery disease with those of healthy subjects. The mean resting and stress MBFMRI values were 0.76 ± 0.10 and 3.04 ± 0.82 mL/min/g, respectively, and showed excellent correlation with the mean MBFPET values (r = 0.96, P < 0.01). The mean stress MBFMRI value was significantly lower for the patients (1.92 ± 0.37) than for the healthy subjects (P < 0.001). The use of dynamic perfusion MRI at 3T is useful for estimating MBF and can be applied for patients with coronary artery disease. © 2014 Wiley Periodicals, Inc.
Aoe, Jo; Watabe, Tadashi; Shimosegawa, Eku; Kato, Hiroki; Kanai, Yasukazu; Naka, Sadahiro; Matsunaga, Keiko; Isohashi, Kayako; Tatsumi, Mitsuaki; Hatazawa, Jun
2018-06-22
Resting-state functional MRI (rs-fMRI) has revealed the existence of a default-mode network (DMN) based on spontaneous oscillations of the blood oxygenation level-dependent (BOLD) signal. The BOLD signal reflects the deoxyhemoglobin concentration, which depends on the relationship between the regional cerebral blood flow (CBF) and the cerebral metabolic rate of oxygen (CMRO 2 ). However, these two factors cannot be separated in BOLD rs-fMRI. In this study, we attempted to estimate the functional correlations in the DMN by means of quantitative 15 O-labeled gases and water PET, and to compare the contribution of the CBF and CMRO 2 to the DMN. Nine healthy volunteers (5 men and 4 women; mean age, 47.0 ± 1.2 years) were studied by means of 15 O-O 2 , 15 O-CO gases and 15 O-water PET. Quantitative CBF and CMRO 2 images were generated by an autoradiographic method and transformed into MNI standardized brain template. Regions of interest were placed on normalized PET images according to the previous rs-fMRI study. For the functional correlation analysis, the intersubject Pearson's correlation coefficients (r) were calculated for all pairs in the brain regions and correlation matrices were obtained for CBF and CMRO 2 , respectively. We defined r > 0.7 as a significant positive correlation and compared the correlation matrices of CBF and CMRO 2 . Significant positive correlations (r > 0.7) were observed in 24 pairs of brain regions for the CBF and 22 pairs of brain regions for the CMRO 2 . Among them, 12 overlapping networks were observed between CBF and CMRO 2 . Correlation analysis of CBF led to the detection of more brain networks as compared to that of CMRO 2 , indicating that the CBF can capture the state of the spontaneous activity with a higher sensitivity. We estimated the functional correlations in the DMN by means of quantitative PET using 15 O-labeled gases and water. The correlation matrix derived from the CBF revealed a larger number of brain networks as compared to that derived from the CMRO 2 , indicating that contribution to the functional correlation in the DMN is higher in the blood flow more than the oxygen consumption.
Autio, Anu; Saraste, Antti; Kudomi, Nobuyuki; Saanijoki, Tiina; Johansson, Jarkko; Liljenbäck, Heidi; Tarkia, Miikka; Oikonen, Vesa; Sipilä, Hannu T; Roivainen, Anne
2014-01-01
Increased blood flow and vascular permeability are key events in inflammation. Based on the fact that Gadolinium-1,4,7,10-tetraazacyclododecane-N,N‘,N‘‘,N‘‘‘-tetraacetic acid (Gd-DOTA) is commonly used in magnetic resonance (MR) imaging of blood flow (perfusion), we evaluated the feasibility of its Gallium-68 labeled DOTA analog (68Ga-DOTA) for positron emission tomography (PET) imaging of blood flow in experimental inflammation. Adult, male Sprague-Dawley rats with turpentine oil induced sterile skin/muscle inflammation were anesthetized with isoflurane, and imaged under rest and adenosine-induced hyperemia by means of dynamic 2-min Oxygen-15 labeled water (H2 15O) and 30-min 68Ga-DOTA PET. For the quantification of PET data, regions of interest (ROIs) were defined in the focus of inflammation, healthy muscle, myocardium and heart left ventricle. Radioactivity concentration in the ROIs versus time after injection was determined for both tracers and blood flow was calculated using image-derived input. According to the H2 15O PET, blood flow was 0.69 ± 0.15 ml/min/g for inflammation and 0.15 ± 0.03 ml/min/g for muscle during rest. The blood flow remained unchanged during adenosine-induced hyperemia 0.67 ± 0.11 and 0.12 ± 0.03 ml/min/g for inflammation and muscle, respectively, indicating that adenosine has little effect on blood flow in peripheral tissues in rats. High focal uptake of 68Ga-DOTA was seen at the site of inflammation throughout the 30-min PET imaging. According to the 68Ga-DOTA PET, blood flow measured as the blood-to-tissue transport rate (K1) was 0.60 ± 0.07 ml/min/g for inflammation and 0.14 ± 0.06 ml/min/g for muscle during rest and 0.63 ± 0.08 ml/min/g for inflammation and 0.09 ± 0.04 ml/min/g for muscle during adenosine-induced hyperemia. The H2 15O-based blood flow and 68Ga-DOTA-based K1 values correlated well (r = 0.94, P < 0.0001). These results show that 68Ga-DOTA PET imaging is useful for the quantification of increased blood flow induced by inflammation. PMID:25250206
Autio, Anu; Saraste, Antti; Kudomi, Nobuyuki; Saanijoki, Tiina; Johansson, Jarkko; Liljenbäck, Heidi; Tarkia, Miikka; Oikonen, Vesa; Sipilä, Hannu T; Roivainen, Anne
2014-01-01
Increased blood flow and vascular permeability are key events in inflammation. Based on the fact that Gadolinium-1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid (Gd-DOTA) is commonly used in magnetic resonance (MR) imaging of blood flow (perfusion), we evaluated the feasibility of its Gallium-68 labeled DOTA analog ((68)Ga-DOTA) for positron emission tomography (PET) imaging of blood flow in experimental inflammation. Adult, male Sprague-Dawley rats with turpentine oil induced sterile skin/muscle inflammation were anesthetized with isoflurane, and imaged under rest and adenosine-induced hyperemia by means of dynamic 2-min Oxygen-15 labeled water (H2 (15)O) and 30-min (68)Ga-DOTA PET. For the quantification of PET data, regions of interest (ROIs) were defined in the focus of inflammation, healthy muscle, myocardium and heart left ventricle. Radioactivity concentration in the ROIs versus time after injection was determined for both tracers and blood flow was calculated using image-derived input. According to the H2 (15)O PET, blood flow was 0.69 ± 0.15 ml/min/g for inflammation and 0.15 ± 0.03 ml/min/g for muscle during rest. The blood flow remained unchanged during adenosine-induced hyperemia 0.67 ± 0.11 and 0.12 ± 0.03 ml/min/g for inflammation and muscle, respectively, indicating that adenosine has little effect on blood flow in peripheral tissues in rats. High focal uptake of (68)Ga-DOTA was seen at the site of inflammation throughout the 30-min PET imaging. According to the (68)Ga-DOTA PET, blood flow measured as the blood-to-tissue transport rate (K1) was 0.60 ± 0.07 ml/min/g for inflammation and 0.14 ± 0.06 ml/min/g for muscle during rest and 0.63 ± 0.08 ml/min/g for inflammation and 0.09 ± 0.04 ml/min/g for muscle during adenosine-induced hyperemia. The H2 (15)O-based blood flow and (68)Ga-DOTA-based K1 values correlated well (r = 0.94, P < 0.0001). These results show that (68)Ga-DOTA PET imaging is useful for the quantification of increased blood flow induced by inflammation.
Temma, Takashi; Yamazaki, Makoto; Miyanohara, Jun; Shirakawa, Hisashi; Kondo, Naoya; Koshino, Kazuhiro; Kaneko, Shuji; Iida, Hidehiro
2017-10-01
Positron emission tomography with 15 O-labeled gases ( 15 O-PET) is important for in vivo measurement of cerebral oxygen metabolism both in clinical and basic settings. However, there are currently no reports concerning 15 O-PET in mice. Here, we developed an 15 O-PET method applicable to mice with spontaneous respiration of 15 O-gas without a tracheotomy catheter. Sequential 15 O-PET was also performed in a mouse model of chronic cerebral hypoperfusion with bilateral common carotid artery stenosis (BCAS) induced by placement of microcoils. 15 O-gas with isoflurane was supplied to the nose of mouse with evacuation of excess 15 O-gas surrounding the body. 15 O-PET was performed on days 3, 7, 14, 21, and 28 after surgery. Cerebral blood flow (CBF), cerebral blood volume, oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO 2 ) were calculated in whole brains. A significant decrease in CBF and compensatory increase in OEF in the BCAS group produced CMRO 2 values comparable to that of the sham group at three days post-operation. Although CBF and OEF in the BCAS group gradually recovered over the first 28 days, the CMRO 2 showed a gradual decrease to 68% of sham values at 28 days post-operation. In conclusion, we successfully developed a noninvasive 15 O-PET method for mice.
Feasibility of hydrogel fiducial markers for in vivo proton range verification using PET
NASA Astrophysics Data System (ADS)
Cho, Jongmin; Campbell, Patrick; Wang, Min; Alqathami, Mamdooh; Mawlawi, Osama; Kerr, Matthew; Cho, Sang Hyun
2016-03-01
Biocompatible/biodegradable hydrogel polymers were immersed in 18O-enriched water and 16O-water to create 18O-water hydrogels and 16O-water hydrogels. In both cases, the hydrogels were made of ~91 wt% water and ~9 wt% polymer. In addition, 5-8 μm Zn powder was suspended in 16O-water and 18O-enriched water and cross-linked with hydrogel polymers to create Zn/16O-water hydrogels (30/70 wt%, ~9 wt% polymer) and Zn/18O-water hydrogels (10/90 wt%), respectively. A block of extra-firm ‘wet’ tofu (12.3 × 8.8 × 4.9 cm, ρ ≈ 1.05 g cm-3) immersed in water was injected with Zn/16O-water hydrogels (0.9 ml each) at four different depths using an 18-gauge needle. Similarly, Zn/18O-water hydrogels (0.9 ml) were injected into a second tofu phantom. As a reference, both 16O-water hydrogels (1.8 ml) and 18O-water hydrogels (0.9 ml) in Petri dishes were irradiated in a ‘dry’ environment. The hydrogels in the wet tofu phantoms and dry Petri dishes were scanned via CT and images were used for treatment planning. Then, they were positioned at the proton distal dose fall-off region and irradiated (2 Gy) followed by PET/CT imaging. Notably high PET signals were observed only in 18O-water hydrogels in the dry environment. The visibility of the Zn/16O-water hydrogels injected into the tofu phantom was outstanding in CT images, but these hydrogels provided no noticeable PET signals. The visibility of the Zn/18O-water hydrogels in the wet tofu were excellent on CT and moderate on PET; however, the PET signals were weaker than those in the dry environment, possibly owing to 18O-water leaching out. The hydrogel markers studied here could be used to develop universal PET/CT fiducial markers. Their PET visibility (attributed more to activated 18O-water than Zn) after proton irradiation can be used for proton therapy/range verification. More investigation is needed to slow down the leaching of 18O-water.
An apparatus for the preparation of [15O]-H2O for rapid repetitive PET studies
NASA Astrophysics Data System (ADS)
Dahl, J. R.; Chaly, T. C.; Matacchieri, R. A.; Yee, A.; Dhawan, V.; Horowitz, S.; Jespersen, K.; Margouleff, D.; Eidelberg, D.
1999-06-01
The use of [15O]-H2O to follow changes in cerebral blood flow using PET has become frequent and widespread, requiring an apparatus easily operated by personnel unfamiliar with the physics and chemistry involved. Oxygen-15 is prepared by the 14N(d,n)15O nuclear reaction using a target of UHP nitrogen with 1% UHP hydrogen added, contained in a target chamber similar to that reported for the preparation of [18F]-F2. Nucleogenic 15O reacts with hydrogen in the target gas to produce [15O]-H2O. Some of the N target reacts with hydrogen to produce NH3, which must be removed. At the end of bombardment (minimum 6 min.) the target gas is released through a small amount of parenteral water which then flows through approximately 50 mg Dowex 50W-X8 resin (100-200 mesh) to remove the NH3. Sufficient 23.4% NaCl solution is added to produce an isotonic solution. The isotonic solution is sterilized by filtration through a 0.22 micron filter into an injection syringe which is sent via pneumatic transport to the PET imaging room. The apparatus, which uses a programmable logic controller and four switches to allow the operator to select standby, refill, collect activity, or deliver dose operations of the production process, provides doses of [15O]-H2O up to 35 mCi/dose at intervals as frequent as seven minutes with minimal radiation exposure to the operators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathias, C.J.; Welch, M.J.; Raichle, M.E.
1990-03-01
Copper(II) pyruvaldehyde bis(N4-methylthiosemicarbazone) (Cu-PTSM), copper(II) pyruvaldehyde bis(N4-dimethylthiosemicarbazone) (Cu-PTSM2), and copper(II) ethylglyoxal bis(N4-methylthiosemicarbazone) (Cu-ETSM), have been proposed as PET tracers for cerebral blood flow (CBF) when labeled with generator-produced 62Cu (t1/2 = 9.7 min). To evaluate the potential of Cu-PTSM for CBF PET studies, baboon single-pass cerebral extraction measurements and PET imaging were carried out with the use of 67Cu (t1/2 = 2.6 days) and 64Cu (t1/2 = 12.7 hr), respectively. All three chelates were extracted into the brain with high efficiency. There was some clearance of all chelates in the 10-50-sec time frame and Cu-PTSM2 continued to clear. Cu-PTSM andmore » Cu-ETSM have high residual brain activity. PET imaging of baboon brain was carried out with the use of (64Cu)-Cu-PTSM. For comparison with the 64Cu brain image, a CBF (15O-labeled water) image (40 sec) was first obtained. Qualitatively, the H2(15)O and (64Cu)-Cu-PTSM images were very similar; for example, a comparison of gray to white matter uptake resulted in ratios of 2.42 for H2(15)O and 2.67 for Cu-PTSM. No redistribution of 64Cu was observed in 2 hr of imaging, as was predicted from the single-pass study results. Quantitative determination of blood flow using Cu-PTSM showed good agreement with blood flow determined with H2(15)O. This data suggests that (62Cu)-Cu-PTSM may be a useful generator-produced radiopharmaceutical for blood flow studies with PET.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herscovitch, P.; Raichle, M.E.; Kilbourn, M.R.
1985-05-01
Tracers used to measure CBF with PET and the Kety autoradiographic approach should freely cross the blood-brain barrier. 0-15 water, which is not freely permeable, may underestimate CBF, especially at higher flows. The authors determined this under-estimation relative to flow measured with a freely diffusible tracer, C-11 butanol and used these data to calculate the extraction (E) and permeability surface area product (PS) for 0-15 water. Paired flow measurements were made with 0-15 water (CBF-wat) and C-11 butanol (CBF-but) in eight normal human subjects. Average CBF-but, 55.6 ml/(min . 100g) was significantly greater than CBF-water, 47.6 ml/(min . 100g). Themore » ratio of regional gray matter (GM) flow to white matter (WM) flow was significantly greater with C-11 butanol, indicating a greater underestimation of CBF with 0-15 water in the higher flow GM. Average E for water was 0.92 in WM and 0.82 in GM. The mean PS in GM, 148 ml/(min . 100g), was significantly greater than in WM, 94 ml/(min . 100g). Simulation studies demonstrated that a measurement error in CBF-wat or CBF-but causes an approximately equivalent error in E but a considerably larger error in PS due to the sensitivity of the equation, PS=-CBF . ln(1-E), to variations in E. Modest errors in E and PS result from tissue heterogeneity that occurs due to the limited spatial resolution of PET. The authors' measurements of E and PS for water are similar to data obtained by more invasive methods and demonstrate the ability of PET to measure brain water permeability.« less
Päivärinta, Johanna; Koivuviita, Niina; Oikonen, Vesa; Iida, Hidehiro; Liukko, Kaisa; Manner, Ilkka; Löyttyniemi, Eliisa; Nuutila, Pirjo; Metsärinne, Kaj
2018-06-11
Microvascular function plays an important role in ARVD (atherosclerotic renovascular disease). RFR (renal flow reserve), the capacity of renal vasculature to dilate, is known to reflect renal microvascular function. In this pilot study, we assessed PET (positron emission tomography)-based RFR values of healthy persons and renal artery stenosis patients. Seventeen patients with ARVD and eight healthy subjects were included in the study. Intravenous enalapril 1 mg was used as a vasodilatant, and the maximum response (blood pressure and RFR) to it was measured at 40 min. Renal perfusion was measured by means of oxygen-15-labeled water PET. RFR was calculated as a difference of stress flow and basal flow and was expressed as percent [(stress blood flow - basal blood flow)/basal blood flow] × 100%. RFR of the healthy was 22%. RFR of the stenosed kidneys of bilateral stenosis patients (27%) was higher than that of the stenosed kidneys of unilateral stenosis patients (15%). RFR of the contralateral kidneys of unilateral stenosis patients was 21%. There was no difference of statistical significance between RFR values of ARVD subgroups or between ARVD subgroups and the healthy. In the stenosed kidneys of unilateral ARVD patients, stenosis grade of the renal artery correlated negatively with basal (p = 0.04) and stress flow (p = 0.02). Dispersion of RFR values was high. This study is the first to report [ 15 O]H 2 O PET-based RFR values of healthy subjects and ARVD patients in humans. The difference between RFR values of ARVD patients and the healthy did not reach statistical significance perhaps because of high dispersion of RFR values. [ 15 O]H 2 O PET is a valuable non-invasive and quantitative method to evaluate renal blood flow though high dispersion makes imaging challenging. Larger studies are needed to get more information about [ 15 O]H 2 O PET method in evaluation of renal blood flow.
Utilization of the CS-30 cyclotron at the Duke University Medical Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wieland, B.W.; McKinney, C.J.; Dailey, M.F.
1994-12-31
Present routine radionuclide production includes {sup 18}F fluoride from protons on {sup 18}O water, {sup 13}N ammonia from protons on {sup 13}C slurry, {sup 15}O water from deuterons on nitrogen gas, and {sup 211}At from alphas on bismuth metal. Clinical PET using two tomographs (GE 4096 and Advance) is done Tuesday through Friday, typically 4 to 11 patients per day using {sup 15}O water, {sup 13}N ammonia, and {sup 18}F FDG synthesized with a GE Microlab. Clinical patient studies are 50% neurology using FDG, 45% body using FDG, and 5% cardiology using ammonia and FDG (oncology in these three areasmore » totals 60%). {sup 15}O water for clinical research patients (THC and cognitive) is produced twice a week. {sup 211}At is produced about twice a week for monoclonal antibody labelling.« less
NASA Astrophysics Data System (ADS)
Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Iida, Hidehiro
2007-04-01
Cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF) and cerebral blood flow (CBF) images can be quantified using positron emission tomography (PET) by administrating 15O-labelled water (H152O) and oxygen (15O2). Conventionally, those images are measured with separate scans for three tracers C15O for CBV, H152O for CBF and 15O2 for CMRO2, and there are additional waiting times between the scans in order to minimize the influence of the radioactivity from the previous tracers, which results in a relatively long study period. We have proposed a dual tracer autoradiographic (DARG) approach (Kudomi et al 2005), which enabled us to measure CBF, OEF and CMRO2 rapidly by sequentially administrating H152O and 15O2 within a short time. Because quantitative CBF and CMRO2 values are sensitive to arterial input function, it is necessary to obtain accurate input function and a drawback of this approach is to require separation of the measured arterial blood time-activity curve (TAC) into pure water and oxygen input functions under the existence of residual radioactivity from the first injected tracer. For this separation, frequent manual sampling was required. The present paper describes two calculation methods: namely a linear and a model-based method, to separate the measured arterial TAC into its water and oxygen components. In order to validate these methods, we first generated a blood TAC for the DARG approach by combining the water and oxygen input functions obtained in a series of PET studies on normal human subjects. The combined data were then separated into water and oxygen components by the present methods. CBF and CMRO2 were calculated using those separated input functions and tissue TAC. The quantitative accuracy in the CBF and CMRO2 values by the DARG approach did not exceed the acceptable range, i.e., errors in those values were within 5%, when the area under the curve in the input function of the second tracer was larger than half of the first one. Bias and deviation in those values were also compatible to that of the conventional method, when noise was imposed on the arterial TAC. We concluded that the present calculation based methods could be of use for quantitatively calculating CBF and CMRO2 with the DARG approach.
Hiroshima, Yuji; Manabe, Osamu; Naya, Masanao; Tomiyama, Yuuki; Magota, Keiichi; Obara, Masahiko; Aikawa, Tadao; Oyama-Manabe, Noriko; Yoshinaga, Keiichiro; Hirata, Kenji; Kroenke, Markus; Tamaki, Nagara; Katoh, Chietsugu
2017-12-21
11 C-hydroxyephedrine (HED) PET has been used to evaluate the myocardial sympathetic nervous system (SNS). Here we sought to establish a simultaneous approach for quantifying both myocardial blood flow (MBF) and the SNS from a single HED PET scan. Ten controls and 13 patients with suspected cardiac disease were enrolled. The inflow rate of 11 C-HED (K1) was obtained using a one-tissue-compartment model. We compared this rate with the MBF derived from 15 O-H 2 O PET. In the controls, the relationship between K 1 from 11 C-HED PET and the MBF from 15 O-H 2 O PET was linked by the Renkin-Crone model. The relationship between K 1 from 11 C-HED PET and the MBF from 15 O-H 2 O PET from the controls' data was approximated as follows: K 1 = (1 - 0.891 * exp(- 0.146/MBF)) * MBF. In the validation set, the correlation coefficient demonstrated a significantly high relationship for both the whole left ventricle (r = 0.95, P < 0.001) and three coronary territories (left anterior descending artery: r = 0.96, left circumflex artery: r = 0.81, right coronary artery: r = 0.86; P < 0.001, respectively). 11 C-HED can simultaneously estimate MBF and sympathetic nervous function without requiring an additional MBF scan for assessing mismatch areas between MBF and SNS.
NASA Astrophysics Data System (ADS)
Fung, Edward K.; Carson, Richard E.
2013-03-01
Full quantitative analysis of brain PET data requires knowledge of the arterial input function into the brain. Such data are normally acquired by arterial sampling with corrections for delay and dispersion to account for the distant sampling site. Several attempts have been made to extract an image-derived input function (IDIF) directly from the internal carotid arteries that supply the brain and are often visible in brain PET images. We have devised a method of delineating the internal carotids in co-registered magnetic resonance (MR) images using the level-set method and applying the segmentations to PET images using a novel centerline approach. Centerlines of the segmented carotids were modeled as cubic splines and re-registered in PET images summed over the early portion of the scan. Using information from the anatomical center of the vessel should minimize partial volume and spillover effects. Centerline time-activity curves were taken as the mean of the values for points along the centerline interpolated from neighboring voxels. A scale factor correction was derived from calculation of cerebral blood flow (CBF) using gold standard arterial blood measurements. We have applied the method to human subject data from multiple injections of [15O]water on the HRRT. The method was assessed by calculating the area under the curve (AUC) of the IDIF and the CBF, and comparing these to values computed using the gold standard arterial input curve. The average ratio of IDIF to arterial AUC (apparent recovery coefficient: aRC) across 9 subjects with multiple (n = 69) injections was 0.49 ± 0.09 at 0-30 s post tracer arrival, 0.45 ± 0.09 at 30-60 s, and 0.46 ± 0.09 at 60-90 s. Gray and white matter CBF values were 61.4 ± 11.0 and 15.6 ± 3.0 mL/min/100 g tissue using sampled blood data. Using IDIF centerlines scaled by the average aRC over each subjects’ injections, gray and white matter CBF values were 61.3 ± 13.5 and 15.5 ± 3.4 mL/min/100 g tissue. Using global average aRC values, the means were unchanged, and intersubject variability was noticeably reduced. This MR-based centerline method with local re-registration to [15O]water PET yields a consistent IDIF over multiple injections in the same subject, thus permitting the absolute quantification of CBF without arterial input function measurements.
Heijtel, D F R; Petersen, E T; Mutsaerts, H J M M; Bakker, E; Schober, P; Stevens, M F; van Berckel, B N M; Majoie, C B L M; Booij, J; van Osch, M J P; van Bavel, E T; Boellaard, R; Lammertsma, A A; Nederveen, A J
2016-04-01
The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P < 0.05), although QUASAR significantly underestimated CBF by 30% (P < 0.001). CBVA was moderately correlated (r(2): 0.28-0.43, P < 0.05), with QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P < 0.001). Group-wise voxel statistics identified minor areas with significant contrast differences between [(15)O]H2O PET and QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies. Copyright © 2016 John Wiley & Sons, Ltd.
Production of an 15O beam using a stable oxygen ion beam for in-beam PET imaging
NASA Astrophysics Data System (ADS)
Mohammadi, Akram; Yoshida, Eiji; Tashima, Hideaki; Nishikido, Fumihiko; Inaniwa, Taku; Kitagawa, Atsushi; Yamaya, Taiga
2017-03-01
In advanced ion therapy, the 15O ion beam is a promising candidate to treat hypoxic tumors and simultaneously monitor the delivered dose to a patient using PET imaging. This study aimed at production of an 15O beam by projectile fragmentation of a stable 16O beam in an optimal material, followed by in-beam PET imaging using a prototype OpenPET system, which was developed in the authors' group. The study was carried out in three steps: selection of the optimal target based on the highest production rate of 15O fragments; experimental production of the beam using the optimal target in the Heavy Ion Medical Accelerator Chiba (HIMAC) secondary beam course; and realization of in-beam PET imaging for the produced beam. The optimal target evaluations were done using the Monte Carlo simulation code PHITS. The fluence and mean energy of the secondary particles were simulated and the optimal target was selected based on the production rate of 15O fragments. The highest production rate of 15O was observed for a liquid hydrogen target, 3.27% for a 53 cm thick target from the 16O beam of 430 MeV/u. Since liquid hydrogen is not practically applicable in the HIMAC secondary beam course a hydrogen-rich polyethylene material, which was the second optimal target from the simulation results, was selected as the experimental target. Three polyethylene targets with thicknesses of 5, 11 or 14 cm were used to produce the 15O beam without any degrader in the beam course. The highest production rate was measured as around 0.87% for the 11 cm thick polyethylene target from the 16O beam of 430 MeV/u when the angular acceptance and momentum acceptance were set at ±13 mrad and ±2.5%, respectively. The purity of the produced beam for the three targets were around 75%, insufficient for clinical application, but it was increased to 97% by inserting a wedge shape aluminum degrader with a thickness of 1.76 cm into the beam course and that is sufficiently high. In-beam PET imaging was also performed for all produced beams using the OpenPET system. The purity improvement of the produced 15O beams was confirmed from the PET images.
Dunnwald, Lisa K.; Gralow, Julie R.; Ellis, Georgiana K.; Livingston, Robert B.; Linden, Hannah M.; Specht, Jennifer M.; Doot, Robert K.; Lawton, Thomas J.; Barlow, William E.; Kurland, Brenda F.; Schubert, Erin K.; Mankoff, David A.
2008-01-01
Purpose Patients with locally advanced breast carcinoma (LABC) receive preoperative chemotherapy to provide early systemic treatment and assess in vivo tumor response. Serial positron emission tomography (PET) has been shown to predict pathologic response in this setting. We evaluated serial quantitative PET tumor blood flow (BF) and metabolism as in vivo measurements to predict patient outcome. Patients and Methods Fifty-three women with primary LABC underwent dynamic [18F]fluorodeoxyglucose (FDG) and [15O]water PET scans before and at midpoint of neoadjuvant chemotherapy. The FDG metabolic rate (MRFDG) and transport (FDG K1) parameters were calculated; BF was estimated from the [15O]water study. Associations between BF, MRFDG, FDG K1, and standardized uptake value and disease-free survival (DFS) and overall survival (OS) were evaluated using the Cox proportional hazards model. Results Patients with persistent or elevated BF and FDG K1 from baseline to midtherapy had higher recurrence and mortality risks than patients with reductions. In multivariable analyses, BF and FDG K1 changes remained independent prognosticators of DFS and OS. For example, in the association between BF and mortality, a patient with a 5% increase in tumor BF had a 67% higher mortality risk compared with a patient with a 5% decrease in tumor BF (hazard ratio = 1.67; 95% CI, 1.24 to 2.24; P < .001). Conclusion LABC patients with limited or no decline in BF and FDG K1 experienced higher recurrence and mortality risks that were greater than the effects of clinical tumor characteristics. Tumor perfusion changes over the course of neoadjuvant chemotherapy measured directly by [15O]water or indirectly by dynamic FDG predict DFS and OS. PMID:18626006
Reconstruction of an input function from a dynamic PET water image using multiple tissue curves
NASA Astrophysics Data System (ADS)
Kudomi, Nobuyuki; Maeda, Yukito; Yamamoto, Yuka; Nishiyama, Yoshihiro
2016-08-01
Quantification of cerebral blood flow (CBF) is important for the understanding of normal and pathologic brain physiology. When CBF is assessed using PET with {{\\text{H}}2} 15O or C15O2, its calculation requires an arterial input function, which generally requires invasive arterial blood sampling. The aim of the present study was to develop a new technique to reconstruct an image derived input function (IDIF) from a dynamic {{\\text{H}}2} 15O PET image as a completely non-invasive approach. Our technique consisted of using a formula to express the input using tissue curve with rate constant parameter. For multiple tissue curves extracted from the dynamic image, the rate constants were estimated so as to minimize the sum of the differences of the reproduced inputs expressed by the extracted tissue curves. The estimated rates were used to express the inputs and the mean of the estimated inputs was used as an IDIF. The method was tested in human subjects (n = 29) and was compared to the blood sampling method. Simulation studies were performed to examine the magnitude of potential biases in CBF and to optimize the number of multiple tissue curves used for the input reconstruction. In the PET study, the estimated IDIFs were well reproduced against the measured ones. The difference between the calculated CBF values obtained using the two methods was small as around <8% and the calculated CBF values showed a tight correlation (r = 0.97). The simulation showed that errors associated with the assumed parameters were <10%, and that the optimal number of tissue curves to be used was around 500. Our results demonstrate that IDIF can be reconstructed directly from tissue curves obtained through {{\\text{H}}2} 15O PET imaging. This suggests the possibility of using a completely non-invasive technique to assess CBF in patho-physiological studies.
A continuous [15O]H2O production and infusion system for PET imaging
NASA Astrophysics Data System (ADS)
Sajjad, Munawwar; Liow, Jeih-San
1999-06-01
A system for continuous production and infusion of [15O]H2O has been designed for PET cerebral blood flow studies. The injection system consists of a four-port-two-position valve, two Horizon Nxt infusion pumps, and a sterile 50 ml vial. The variation of the production of [15O]H2O was <1%. The variation of activity delivered measured by scanner counts during the steady state period was <2%.
Brain PET and functional MRI: why simultaneously using hybrid PET/MR systems?
Cecchin, Diego; Palombit, Alessandro; Castellaro, Marco; Silvestri, Erica; Bui, Franco; Barthel, Henryk; Sabri, Osama; Corbetta, Maurizio; Bertoldo, Alessandra
2017-12-01
In the last 20 years growing attention has been devoted to multimodal imaging. The recent literature is rich of clinical and research studies that have been performed using different imaging modalities on both separate and integrated positron emission tomography (PET) and magnetic resonance (MR) scanners. However, today, hybrid PET/MR systems measure signals related to brain structure, metabolism, neurochemistry, perfusion, and neuronal activity simultaneously, i.e. in the same physiological conditions. A frequently raised question at meeting and symposia is: "Do we really need a hybrid PET/MR system? Are there any advantages over acquiring sequential and separate PET and MR scans?" The present paper is an attempt to answer these questions specifically in relation to PET combined with functional magnetic resonance imaging (fMRI) and arterial spin labeling. We searched (last update: June 2017) the databases PubMed, PMC, Google Scholar and Medline. We also included additional studies if they were cited in the selected articles. No language restriction was applied to the search, but the reviewed articles were all in English. Among all the retrieved articles, we selected only those performed using a hybrid PET/MR system. We found a total of 17 papers that were selected and discussed in three main groups according to the main radiopharmaceutical used: 18F-fluorodeoxyglucose (18F-FDG) (N.=8), 15O-water (15O-H2O) (N.=3) and neuroreceptors (N.=6). Concerning studies using 18F-FDG, simultaneous PET/fMRI revealed that global aspects of functional organization (e.g. graph properties of functional connections) are partially associated with energy consumption. There are remarkable spatial and functional similarities across modalities, but also discrepant findings. More work is needed on this point. There are only a handful of papers comparing blood flow measurements with PET 15O-H2O and MR arterial spin label (ASL) measures, and they show significant regional CBF differences between these two modalities. However, at least in one study the correlation at the level of gray, white matter, and whole brain is rather good (r=0.94, 0.8, 0.81 respectively). Finally, receptor studies show that simultaneous PET/fMRI could be a useful tool to characterize functional connectivity along with dynamic neuroreceptor adaptation in several physiological (e.g. working memory) or pathological (e.g. pain) conditions, with or without drug administrations. The simultaneous acquisition of PET (using a number of radiotracers) and functional MRI (using a number of sequences) offers exciting opportunities that we are just beginning to explore. The results thus far are promising in the evaluation of cerebral metabolism/flow, neuroreceptor adaptation, and network's energetic demand.
Positron emission tomography in cardiovascular disease.
Beanlands, R
1996-10-01
Positron emission tomography (PET) represents an advanced form of nuclear imaging technology. The use of positron emitting isotopes, such as C-11, O-15, N-13, and F-18 permit radiolabelling of naturally occurring compounds in the body or close analogues. This, combined with technical advantages of PET imaging, allow quantification of physiological processes in humans. PET has become established as the most accurate noninvasive means for the diagnosis of coronary artery disease using myocardial perfusion radiotracers, which include rubidium-82, N-13-amonia, and O-15-water. These approaches have also been applied for long term evaluation of the effects of therapy and for the quantification of myocardial bloodflow. Radiolabelling of metabolic substrates, including C-11 palmitate, C-11 acetate and F-18 flurodeoxyglucose (FDG) have permitted evaluation of myocardial metabolism. F-18 FDG PET imaging has been established as the best means for defining viable myocardium in patients with reduced ventricular function being considered for revascularization. FDG PET can also identify patients being considered for cardiac transplant, who may be candidates for revascularization. In this review, other applications for metabolic, autonomic nervous system and receptor imaging are also discussed. The availability of cardiac PET in Canada is currently limited. However, with the reducing costs of capital and more cost effectiveness data, PET may become more widely available. Cardiac PET imaging is established as a tremendous diagnostic tool for defining viable myocardium, assessment of perfusion and long term evaluation of therapy without invasive procedures. PET is also a vital research tool capable of evaluating flow, metabolism, myocardial receptors, autonomic nervous system and potentially radiolabelled drugs. Cardiac PET imaging will continue to provide important insight, expanding our understanding and treatment of patients with cardiovascular disease.
NASA Astrophysics Data System (ADS)
Hori, Yuki; Hirano, Yoshiyuki; Koshino, Kazuhiro; Moriguchi, Tetsuaki; Iguchi, Satoshi; Yamamoto, Akihide; Enmi, Junichiro; Kawashima, Hidekazu; Zeniya, Tsutomu; Morita, Naomi; Nakagawara, Jyoji; Casey, Michael E.; Iida, Hidehiro
2014-09-01
Use of 15O labeled oxygen (15O2) and positron emission tomography (PET) allows quantitative assessment of the regional metabolic rate of oxygen (CMRO2) in vivo, which is essential to understanding the pathological status of patients with cerebral vascular and neurological disorders. The method has, however, been challenging, when a 3D PET scanner is employed, largely attributed to the presence of gaseous radioactivity in the trachea and the inhalation system, which results in a large amount of scatter and random events in the PET assessment. The present study was intended to evaluate the adequacy of using a recently available commercial 3D PET scanner in the assessment of regional cerebral radioactivity distribution during an inhalation of 15O2. Systematic experiments were carried out on a brain phantom. Experiments were also performed on a healthy volunteer following a recently developed protocol for simultaneous assessment of CMRO2 and cerebral blood flow, which involves sequential administration of 15O2 and C15O2. A particular intention was to evaluate the adequacy of the scatter-correction procedures. The phantom experiment demonstrated that errors were within 3% at the practically maximum radioactivity in the face mask, with the greatest radioactivity in the lung. The volunteer experiment demonstrated that the counting rate was at peak during the 15O gas inhalation period, within a verified range. Tomographic images represented good quality over the entire FOV, including the lower part of the cerebral structures and the carotid artery regions. The scatter-correction procedures appeared to be important, particularly in the process to compensate for the scatter originating outside the FOV. Reconstructed images dramatically changed if the correction was carried out using inappropriate procedures. This study demonstrated that accurate reconstruction could be obtained when the scatter compensation was appropriately carried out. This study also suggested the feasibility of using a state-of-the-art 3D PET scanner in the quantitative PET imaging during inhalation of 15O labeled oxygen.
Ibaraki, Masanobu; Sato, Kaoru; Mizuta, Tetsuro; Kitamura, Keishi; Miura, Shuichi; Sugawara, Shigeki; Shinohara, Yuki; Kinoshita, Toshibumi
2009-09-01
A modified version of row-action maximum likelihood algorithm (RAMLA) using a 'subset-dependent' relaxation parameter for noise suppression, or dynamic RAMLA (DRAMA), has been proposed. The aim of this study was to assess the capability of DRAMA reconstruction for quantitative (15)O brain positron emission tomography (PET). Seventeen healthy volunteers were studied using a 3D PET scanner. The PET study included 3 sequential PET scans for C(15)O, (15)O(2) and H (2) (15) O. First, the number of main iterations (N (it)) in DRAMA was optimized in relation to image convergence and statistical image noise. To estimate the statistical variance of reconstructed images on a pixel-by-pixel basis, a sinogram bootstrap method was applied using list-mode PET data. Once the optimal N (it) was determined, statistical image noise and quantitative parameters, i.e., cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral metabolic rate of oxygen (CMRO(2)) and oxygen extraction fraction (OEF) were compared between DRAMA and conventional FBP. DRAMA images were post-filtered so that their spatial resolutions were matched with FBP images with a 6-mm FWHM Gaussian filter. Based on the count recovery data, N (it) = 3 was determined as an optimal parameter for (15)O PET data. The sinogram bootstrap analysis revealed that DRAMA reconstruction resulted in less statistical noise, especially in a low-activity region compared to FBP. Agreement of quantitative values between FBP and DRAMA was excellent. For DRAMA images, average gray matter values of CBF, CBV, CMRO(2) and OEF were 46.1 +/- 4.5 (mL/100 mL/min), 3.35 +/- 0.40 (mL/100 mL), 3.42 +/- 0.35 (mL/100 mL/min) and 42.1 +/- 3.8 (%), respectively. These values were comparable to corresponding values with FBP images: 46.6 +/- 4.6 (mL/100 mL/min), 3.34 +/- 0.39 (mL/100 mL), 3.48 +/- 0.34 (mL/100 mL/min) and 42.4 +/- 3.8 (%), respectively. DRAMA reconstruction is applicable to quantitative (15)O PET study and is superior to conventional FBP in terms of image quality.
A simple on-line arterial time-activity curve detector for [O-15] water PET studies
NASA Astrophysics Data System (ADS)
Wollenweber, S. D.; Hichwa, R. D.; Ponto, L. L. B.
1997-08-01
A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAG) for bolus-injection [O-15] water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve for dispersion in external tubing is unnecessary. The [O-15] positrons emanating from blood within a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is reduced to insignificant levels by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) determined from an autoradiographic model and from the TAC measured by 1-second automated sampling was compared to that calculated from a TAC acquired using 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector.
Katoh, Chietsugu; Yoshinaga, Keiichiro; Klein, Ran; Kasai, Katsuhiko; Tomiyama, Yuuki; Manabe, Osamu; Naya, Masanao; Sakakibara, Mamoru; Tsutsui, Hiroyuki; deKemp, Robert A; Tamaki, Nagara
2012-08-01
Myocardial blood flow (MBF) estimation with (82)Rubidium ((82)Rb) positron emission tomography (PET) is technically difficult because of the high spillover between regions of interest, especially due to the long positron range. We sought to develop a new algorithm to reduce the spillover in image-derived blood activity curves, using non-uniform weighted least-squares fitting. Fourteen volunteers underwent imaging with both 3-dimensional (3D) (82)Rb and (15)O-water PET at rest and during pharmacological stress. Whole left ventricular (LV) (82)Rb MBF was estimated using a one-compartment model, including a myocardium-to-blood spillover correction to estimate the corresponding blood input function Ca(t)(whole). Regional K1 values were calculated using this uniform global input function, which simplifies equations and enables robust estimation of MBF. To assess the robustness of the modified algorithm, inter-operator repeatability of 3D (82)Rb MBF was compared with a previously established method. Whole LV correlation of (82)Rb MBF with (15)O-water MBF was better (P < .01) with the modified spillover correction method (r = 0.92 vs r = 0.60). The modified method also yielded significantly improved inter-operator repeatability of regional MBF quantification (r = 0.89) versus the established method (r = 0.82) (P < .01). A uniform global input function can suppress LV spillover into the image-derived blood input function, resulting in improved precision for MBF quantification with 3D (82)Rb PET.
Positron-emitting myocardial blood flow tracers and clinical potential.
Schindler, Thomas H
2015-01-01
Positron-emitting myocardial flow radiotracers such as (15)O-water, (13)N-ammonia and (82)Rubidium in conjunction with positron-emission-tomography (PET) are increasingly applied in clinical routine for coronary artery disease (CAD) detection, yielding high diagnostic accuracy, while providing valuable information on cardiovascular (CV) outcome. Owing to a cyclotron dependency of (15)O-water and (13)N-ammonia, their clinical use for PET myocardial perfusion imaging is limited to a few centers. This limitation could be overcome by the increasing use of (82)Rubidium as it can be eluted from a commercially available (82)Strontium generator and, thus, is independent of a nearby cyclotron. Another novel F-18-labeled myocardial flow radiotracer is flurpiridaz which has attracted increasing interest due to its excellent radiotracer characteristics for perfusion and flow imaging with PET. In particular, the relatively long half-life of 109 minutes of flurpiridaz may afford a general application of this radiotracer for PET perfusion imaging comparable to technetium-99m-labeled single-photon emission computed tomography (SPECT). The ability of PET in conjunction with several radiotracers to assess myocardial blood flow (MBF) in ml/g/min at rest and during vasomotor stress has contributed to unravel pathophysiological mechanisms underlying coronary artery disease (CAD), to improve the detection and characterization of CAD burden in multivessel disease, and to provide incremental prognostic information in individuals with subclinical and clinically-manifest CAD. The concurrent evaluation of myocardial perfusion and MBF may lead to a new era of a personalized, image-guided therapy approach that may offer potential to further improve clinical outcome in CV disease patients but needing validation in large-scale clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.
Mapping {sup 15}O Production Rate for Proton Therapy Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grogg, Kira; Alpert, Nathaniel M.; Zhu, Xuping
Purpose: This work was a proof-of-principle study for the evaluation of oxygen-15 ({sup 15}O) production as an imaging target through the use of positron emission tomography (PET), to improve verification of proton treatment plans and to study the effects of perfusion. Methods and Materials: Dynamic PET measurements of irradiation-produced isotopes were made for a phantom and rabbit thigh muscles. The rabbit muscle was irradiated and imaged under both live and dead conditions. A differential equation was fitted to phantom and in vivo data, yielding estimates of {sup 15}O production and clearance rates, which were compared to live versus dead rates formore » the rabbit and to Monte Carlo predictions. Results: PET clearance rates agreed with decay constants of the dominant radionuclide species in 3 different phantom materials. In 2 oxygen-rich materials, the ratio of {sup 15}O production rates agreed with the expected ratio. In the dead rabbit thighs, the dynamic PET concentration histories were accurately described using {sup 15}O decay constant, whereas the live thigh activity decayed faster. Most importantly, the {sup 15}O production rates agreed within 2% (P>.5) between conditions. Conclusions: We developed a new method for quantitative measurement of {sup 15}O production and clearance rates in the period immediately following proton therapy. Measurements in the phantom and rabbits were well described in terms of {sup 15}O production and clearance rates, plus a correction for other isotopes. These proof-of-principle results support the feasibility of detailed verification of proton therapy treatment delivery. In addition, {sup 15}O clearance rates may be useful in monitoring permeability changes due to therapy.« less
H2(15)O or 13NH3 PET and electromagnetic tomography (LORETA) during partial status epilepticus.
Zumsteg, D; Wennberg, R A; Treyer, V; Buck, A; Wieser, H G
2005-11-22
The authors evaluated the feasibility and source localization utility of H2(15)O or 13NH3 PET and low-resolution electromagnetic tomography (LORETA) in three patients with partial status epilepticus (SE). Results were correlated with findings from intraoperative electrocorticographic recordings and surgical outcomes. PET studies of cerebral blood flow and noninvasive source modeling with LORETA using statistical nonparametric mapping provided useful information for localizing the ictal activity in patients with partial SE.
Suresh Kumar, P; Sundaramurthy, J; Mangalaraj, D; Nataraj, D; Rajarathnam, D; Srinivasan, M P
2011-11-01
A simple and cost-effective successive ionic layer adsorption and reaction (SILAR) method was adopted to fabricate hydrophobic ZnO nanostructured surfaces on transparent indium-tin oxide (ITO), glass and polyethylene terephthalate (PET) substrates. ZnO films deposited on different substrates show hierarchical structures like spindle, flower and spherical shape with diameters ranging from 30 to 300 nm. The photo-induced switching behaviors of ZnO film surfaces between hydrophobic and hydrophilic states were examined by water contact angle and X-ray photoelectron spectroscopy (XPS) analysis. ZnO nanostructured films had contact angles of ~140° and 160°±2 on glass and PET substrates, respectively, exhibiting hydrophobic behavior without any surface modification or treatment. Upon exposure to ultraviolet (UV) illumination, the films showed hydrophilic behavior (contact angle: 15°±2), which upon low thermal stimuli revert back to its original hydrophobic nature. Such reversible and repeatable switching behaviors were observed upon cyclical exposure to ultraviolet radiation. These biomimetic ZnO surfaces exhibit good anti-reflective properties with lower reflectance of 9% for PET substrates. Thus, the present work is significant in terms of its potential application in switching devices, solar coatings and self-cleaning smart windows. Copyright © 2011 Elsevier Inc. All rights reserved.
Repeatability of cold pressor test-induced flow increase assessed with H(2)(15)O and PET.
Siegrist, Patrick T; Gaemperli, Oliver; Koepfli, Pascal; Schepis, Tiziano; Namdar, Mehdi; Valenta, Ines; Aiello, Floreana; Fleischmann, Samuel; Alkadhi, Hatem; Kaufmann, Philipp A
2006-09-01
The aim of this study was to evaluate the repeatability of endothelium-related myocardial blood flow (MBF) responses to cold pressor testing (CPT) as assessed by PET. In 10 age-matched control subjects (26.6 +/- 3.4 y) and 10 tobacco smokers (24.9 +/- 3.3 y) MBF was assessed at rest and after repeated CPT (CPT1 and CPT2, 40 min apart) using PET with H(2)(15)O. CPT was performed by a 2-min immersion of the subject's foot in ice water. MBF values were corrected for cardiac workload (rate.pressure product), and the repeatability of CPT-related MBF values was assessed according to Bland and Altman. Corrected MBF at CPT1 and CPT2 were comparable in control subjects (1.79 +/- 0.37 vs. 1.70 +/- 0.35 mL/min/g; P = not significant [NS]) and in smokers (1.97 +/- 0.42 vs. 1.80 +/- 0.41 mL/min/g; P = NS). Repeatability coefficients in control subjects and smokers were 0.46 mL/min/g (27% of the mean MBF) and 0.51 mL/min/g (27%), respectively. MBF increased significantly after CPT in both groups but tended to be lower in smokers (P = 0.08). PET measured MBF combined with CPT is a feasible and repeatable method for the evaluation of endothelium-related changes of MBF.
Rashid, Ahmed Nafis; Tsuru, Kanji; Ishikawa, Kunio
2015-05-01
Ozone (O3 ) treatment of polyethylene terephthalate (PET) in distilled water was performed in the presence and absence of calcium (Ca(2+) ). PET was oxidized and thus carboxylic and hydroxyl functional groups were introduced on its surface after O3 treatment, regardless of the presence or absence of Ca(2+) . In the case of O3 treatment with Ca(2+) , PET surface was modified with Ca(2+) . Ca(2+) immobilization was confirmed by X-ray photoelectron spectrometric analysis. Hydrophilicity was investigated by measuring contact angles (CA). CA of PET decreased significantly after ozonation. Surface topography of PET before and after ozone treatment was observed by scanning electron microscopy, and showed no morphological changes. In vitro studies showed enhanced rat bone marrow cell responses on the O3 -treated PET surface. Ca(2+) -O3 oxidation at 37°C for 6 h is expected to be an effective method to fabricate PET with good biocompatibility. © 2014 Wiley Periodicals, Inc.
Dose fractionation and single subject studies in PET
NASA Astrophysics Data System (ADS)
Balakrishnan, Karthikayan
Conventional positron emission tomography (PET) for cognitive brain studies typically relies on information collected from the distribution of decays following an injection of 15O-labeled water. The number of injections that can be administered to the subject are constrained by radiation dose to the subject and total length of the PET scan. The standard protocol involves 8--10 injections of H152O separated by approximately 5--7 half-lives of 15O. The number of activation conditions that can be realistically studied in a standard PET session is between 8 and 10. This work investigates the physiological response of a simulated subject to H152O injections that are administered in small doses (1--5 mCi) with short inter-injection intervals (40--180 seconds). A larger number of activation conditions are presented to the subject with a wider variation in the activation paradigm. Repeat conditions are studies. Signal averaging methods are feasible with this method of dose administration. Sinograms from scans with similar activation conditions are summed together before reconstruction. The signal in the primary activation region of the brain is shown to increase while suppressing the contribution of secondary activation regions in the brain. The contrast of the final image is similarly increased which leads to easier identification of the primary activation region. An automated H152O -production unit controlled by a PC running LabView software was developed to produce the dose required for the injection sequence by controlling the flow of H152O -vapor that diffuses across a semi-permeable membrane into saline. The unit is capable of producing H152O rapidly for both the standard and the proposed dose administration methods. The system also detects the bolus arrival time at the subject's lungs using a small external plastic detector. Activation sequence commences with the rise in radioactivity observed by the detector. The simulations indicate that inter-injection intervals should be approximately 90 seconds apart. Contrast in the resulting images are higher than the standard methods. Secondary activation regions that confound primary activations are absent in the low-dose method. The results also indicate that the automated H152O maker is capable of producing and injecting the dose in the required succession under appropriate computer control.
da Silva, E A; Müller, R A; Chugani, D C; Shah, J; Shah, A; Watson, C; Chugani, H T
1999-01-01
Intermittent photic stimulation (IPS) is an activation procedure used during electroencephalogram (EEG) recording to elicit paroxysmal discharges in individuals with photosensitivity. Specific responses on EEG recording may be provoked by IPS at different frequencies of flickering in normal individuals and in patients with photosensitive epilepsy. Changes in regional cerebral blood flow (rCBF) were studied during IPS in two groups of subjects by using [15O]-water positron emission tomography (PET): a control group consisting of eight healthy adults with photic driving response during IPS on EEG recording (mean age, 25 +/- 10.5 years) without history of neurologic or psychiatric abnormalities and a patient group consisting of four adults (mean age, 33 +/- 7.5 years) with history of photosensitive epilepsy. [15O]-water PET scanning with concomitant EEG monitoring was performed during baseline and IPS at 4-, 14-, and 30-Hz frequencies. The control group showed photic driving response at 14-Hz IPS frequency. The patient group showed photoparoxysmal response at 14 and 30 Hz, but not at 4 Hz. Changes in rCBF were determined by means of statistical parametric mapping. Increases in rCBF in occipital cortex (Brodmann's areas 17, 18, and 19) were observed in both groups. In addition, during photic driving responses, the control group showed rCBF increases in the insula and in the thalamus, on the right side. The patient group showed a significant rCBF increase in the hypothalamic region inferior to the left caudate nucleus during photoparoxysmal response. This activation was not found in the control group. Increased rCBF also was observed in the patient group in the head of the left caudate nucleus, in the left hippocampus, and in left insula during IPS without photoparoxysmal response. No activations in these regions were observed during photoparoxysmal response. These data may indicate involvement of the hypothalamus in photosensitive epilepsy and may suggest a modulatory function of the caudate nucleus, which might be associated with an inhibition of epileptic discharges during IPS in patients with photosensitive epilepsy.
The investigation of the Cr doped ZnO thin films deposited by thermionic vacuum arc technique
NASA Astrophysics Data System (ADS)
Mohammadigharehbagh, Reza; Pat, Suat; Musaoglu, Caner; Korkmaz, Şadan; Özen, Soner
2018-02-01
Cr doped ZnO thin films were prepared onto glass and polyethylene terephthalate (PET) substrates using thermionic vacuum arc. XRD patterns show the polycrystalline nature of the films. Cr, Zn, ZnO and Cr2O3 were detected in the layers. The mean crystallite sizes of the films were calculated about 20 nm for the films onto glass and PET substrates. The maximum dislocation density and internal strain values of the films are calculated. According to the optical analysis, the average transmittance and reflectance of the films were found to be approximately 53% and 16% for glass and PET substrates, respectively. The mean refractive index of the layer decreased to 2.15 from 2.38 for the PET substrate. The band gap values of the Cr-doped ZnO thin films were determined as 3.10 and 3.13 eV for glass and PET substrates.
Application of positron emission tomography to neuroimaging in sports sciences.
Tashiro, Manabu; Itoh, Masatoshi; Fujimoto, Toshihiko; Masud, Md Mehedi; Watanuki, Shoichi; Yanai, Kazuhiko
2008-08-01
To investigate exercise-induced regional metabolic and perfusion changes in the human brain, various methods are available, such as positron emission tomography (PET), functional magnetic resonance imaging (fMRI), near-infrared spectroscopy (NIRS) and electroencephalography (EEG). In this paper, details of methods of metabolic measurement using PET, [(18)F]fluorodeoxyglucose ([(18)F]FDG) and [(15)O]radio-labelled water ([(15)O]H(2)O) will be explained. Functional neuroimaging in the field of neuroscience was started in the 1970s using an autoradiography technique on experimental animals. The first human functional neuroimaging exercise study was conducted in 1987 using a rough measurement system known as (133)Xe inhalation. Although the data was useful, more detailed and exact functional neuroimaging, especially with respect to spatial resolution, was achieved by positron emission tomography. Early studies measured the cerebral blood flow changes during exercise. Recently, PET was made more applicable to exercise physiology and psychology by the use of the tracer [(18)F]FDG. This technique allowed subjects to be scanned after an exercise task is completed but still obtain data from the exercise itself, which is similar to autoradiography studies. In this report, methodological information is provided with respect to the recommended protocol design, the selection of the scanning mode, how to evaluate the cerebral glucose metabolism and how to interpret the regional brain activity using voxel-by-voxel analysis and regions of interest techniques (ROI). Considering the important role of exercise in health promotion, further efforts in this line of research should be encouraged in order to better understand health behavior. Although the number of research papers is still limited, recent work has indicated that the [(18)F]FDG-PET technique is a useful tool to understand brain activity during exercise.
Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Oka, Hisashi; Miyake, Yoshinori; Iida, Hidehiro
2010-06-01
Cerebral blood flow (CBF), oxygen extraction fraction (OEF) and cerebral metabolic rate of O(2) (CMRO(2)) can be quantified by PET with the administration of H (2) (15) O and (15)O(2). Recently, a shortening in the duration of these measurements was achieved by the sequential administration of dual tracers of (15)O(2) and H (2) (15) O with PET acquisition and integration method (DARG method). A transmission scan is generally required for correcting photon attenuation in advance of PET scan. Although the DARG method can shorten the total study duration to around 30 min, the transmission scan duration has not been optimized and has possibility to shorten its duration. Our aim of this study was to determine the optimal duration for the transmission scan. We introduced 'N-index', which estimates the noise level on an image obtained by subtracting two statistically independent and physiologically equivalent images. The relationship between noise on functional images and duration of the transmission scan was investigated by N-index. We performed phantom studies to test whether the N-index reflects the pixel noise in a PET image. We also estimated the noise level by the N-index on CBF, OEF and CMRO(2) images from DARG method in clinical patients, and investigated an optimal true count of the transmission scan. We found tight correlation between pixel noise and N-index in the phantom study. By investigating relationship between the transmission scan duration and N-index value for the functional images by DARG method, we revealed that the transmission data with true counts of more than 40 Mcounts results in CBF, OEF, and CMRO(2) images of reasonable quantitative accuracy and quality. The present study suggests that further shortening of DARG measurement is possible by abridging the transmission scan. The N-index could be used to determine the optimal measurement condition when examining the quality of image.
Tomlinson, Ryan E.; Silva, Matthew J.; Shoghi, Kooresh I.
2013-01-01
Purpose Blood flow is an important factor in bone production and repair, but its role in osteogenesis induced by mechanical loading is unknown. Here, we present techniques for evaluating blood flow and fluoride metabolism in a pre-clinical stress fracture model of osteogenesis in rats. Procedures Bone formation was induced by forelimb compression in adult rats. 15O water and 18F fluoride PET imaging were used to evaluate blood flow and fluoride kinetics 7 days after loading. 15O water was modeled using a one-compartment, two-parameter model, while a two-compartment, three-parameter model was used to model 18F fluoride. Input functions were created from the heart, and a stochastic search algorithm was implemented to provide initial parameter values in conjunction with a Levenberg–Marquardt optimization algorithm. Results Loaded limbs are shown to have a 26% increase in blood flow rate, 113% increase in fluoride flow rate, 133% increase in fluoride flux, and 13% increase in fluoride incorporation into bone as compared to non-loaded limbs (p < 0.05 for all results). Conclusions The results shown here are consistent with previous studies, confirming this technique is suitable for evaluating the vascular response and mineral kinetics of osteogenic mechanical loading. PMID:21785919
Advances in PET myocardial perfusion imaging: F-18 labeled tracers.
Rischpler, Christoph; Park, Min-Jae; Fung, George S K; Javadi, Mehrbod; Tsui, Benjamin M W; Higuchi, Takahiro
2012-01-01
Coronary artery disease and its related cardiac disorders represent the most common cause of death in the USA and Western world. Despite advancements in treatment and accompanying improvements in outcome with current diagnostic and therapeutic modalities, it is the correct assignment of these diagnostic techniques and treatment options which are crucial. From a diagnostic standpoint, SPECT myocardial perfusion imaging (MPI) using traditional radiotracers like thallium-201 chloride, Tc-99m sestamibi or Tc-99m tetrofosmin is the most utilized imaging technique. However, PET MPI using N-13 ammonia, rubidium-82 chloride or O-15 water is increasing in availability and usage as a result of the growing number of medical centers with new-generation PET/CT systems taking advantage of the superior imaging properties of PET over SPECT. The routine clinical use of PET MPI is still limited, in part because of the short half-life of conventional PET MPI tracers. The disadvantages of these conventional PET tracers include expensive onsite production and inconvenient on-scanner tracer administration making them unsuitable for physical exercise stress imaging. Recently, two F-18 labeled radiotracers with longer radioactive half-lives than conventional PET imaging agents have been introduced. These are flurpiridaz F 18 (formerly known as F-18 BMS747158-02) and F-18 fluorobenzyltriphenylphosphonium. These longer half-life F-18 labeled perfusion tracers can overcome the production and protocol limitations of currently used radiotracers for PET MPI.
Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR.
Kero, Tanja; Nordström, Jonny; Harms, Hendrik J; Sörensen, Jens; Ahlström, Håkan; Lubberink, Mark
2017-12-01
The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent 15 O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values. Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00. PET-MR-based MBF values correlated well with PET-CT-based MBF values and the parametric PET-MR images were excellent. TOF and reconstruction settings had little impact on MBF values.
Marijuana alters the human cerebellar clock.
O'Leary, Daniel S; Block, Robert I; Turner, Beth M; Koeppel, Julie; Magnotta, Vincent A; Ponto, Laura Boles; Watkins, G Leonard; Hichwa, Richard D; Andreasen, Nancy C
2003-06-11
The effects of marijuana on brain perfusion and internal timing were assessed using [15O] water PET in occasional and chronic users. Twelve volunteers who smoked marijuana recreationally about once weekly, and 12 volunteers who smoked daily for a number of years performed a self-paced counting task during PET imaging, before and after smoking marijuana and placebo cigarettes. Smoking marijuana increased rCBF in the ventral forebrain and cerebellar cortex in both groups, but resulted in significantly less frontal lobe activation in chronic users. Counting rate increased after smoking marijuana in both groups, as did a behavioral measure of self-paced tapping, and both increases correlated with rCBF in the cerebellum. Smoking marijuana appears to accelerate a cerebellar clock altering self-paced behaviors.
Cummings, Kevin J.; Li, Aihua; Deneris, Evan S.
2010-01-01
Neonatal rodents deficient in medullary serotonin neurons have respiratory instability and enhanced spontaneous bradycardias. This study asks if, in Pet-1−/− mice over development: 1) the respiratory instability leads to hypoxia; 2) greater bradycardia is related to the degree of hypoxia or concomitant hypopnea; and 3) hyperthermia exacerbates bradycardias. Pet-1+/+, Pet-1+/−, and Pet-1−/− mice [postnatal days (P) 4–5, P11–12, P14–15] were held at normal body temperature (Tb) and were then made 2°C hypo- and hyperthermic. Using a pneumotach-mask system with ECG, we measured heart rate, metabolic rate (V̇o2), and ventilation. We also calculated indexes for apnea-induced hypoxia (total hypoxia: apnea incidence × O2 consumed during apnea = μl·g−1·min−1) and bradycardia (total bradycardia: bradycardia incidence × magnitude = beats missed/min). Resting heart rate was significantly lower in all Pet-1−/− animals, irrespective of Tb. At P4–5, Pet-1−/− animals had approximately four- to eightfold greater total bradycardia (P < 0.001), owing to an approximately two- to threefold increase in bradycardia magnitude and a near doubling in bradycardia incidence. Pet-1−/− animals had a significantly reduced V̇o2 at all Tb; thus there was no genotype effect on total hypoxia. At P11–12, total bradycardia was nearly threefold greater in hyperthermic Pet-1−/− animals compared with controls (P < 0.01). In both genotypes, bradycardia magnitude was positively related to the degree of hypopnea (P = 0.02), but there was no genotype effect on degree of hypopnea or total hypoxia. At P14–15, genotype had no effect on total bradycardia, but Pet-1−/− animals had up to seven times more total hypoxia (P < 0.001), owing to longer and more frequent apneas and a normalized V̇o2. We infer from these data that 1) Pet-1−/− neonates are probably not hypoxic from respiratory dysfunction until P14–15; 2) neither apnea-related hypoxia nor greater hypopnea contribute to the enhanced bradycardias of Pet-1−/− neonates from approximately P4 to approximately P12; and 3) an enhancement of a temperature-sensitive reflex may contribute to the greater bradycardia in hyperthermic Pet-1−/− animals at approximately P12. PMID:20421636
Wong, Yeun Ying; Raijmakers, Pieter; van Campen, Jasmijn; van der Laarse, Willem J; Knaapen, Paul; Lubberink, Mark; Ruiter, Gerrina; Vonk Noordegraaf, Anton; Lammertsma, Adriaan A
2013-08-01
Idiopathic pulmonary arterial hypertension (IPAH) results in increased right ventricular (RV) workload and oxygen demand. It has been shown that myocardial oxygen consumption (MVO2) of the hypertrophied right ventricle of IPAH patients can be measured using PET and (15)O-labeled tracers. This method is, however, not very suitable for routine clinical practice. The purpose of the present study was to assess whether MVO2 can also be determined in the right ventricle of IPAH patients from the clearance of (11)C-acetate, a simple method that is in use for MVO2 measurements of the left myocardium. Seventeen of 26 IPAH patients performed the total PET study. Nine other patients were scanned only for (11)C-acetate. (15)O-H2O, (15)O-O2, and (15)O-CO scans were used to derive RV flow, oxygen extraction fraction, and blood volume, respectively, from which RV MVO2 was calculated. The rate of clearance determined by monoexponential curve fitting (K(mono)) and the efflux rate constant k2 were derived from the (11)C-acetate scan. The RV rate-pressure product was also determined by means of right heart catheterization, as an index of the RV MVO2, and was calculated as the product of systolic pulmonary artery pressure and heart rate. Both (11)C-acetate clearance rates, K(mono) (R(2) = 0.41, P = 0.006) and k2 (R(2) = 0.45, P = 0.003), correlated with RV MVO2. They also correlated with RV rate-pressure product (K(mono), R(2) = 0.41, P = 0.0005; k2, R(2) = 0.48, P < 0.0001). (11)C-acetate clearance rates correlated moderately with quantitative RV MVO2 measurements in IPAH. Therefore, (11)C-acetate PET can be used only as an index of RV oxidative metabolism in IPAH patients.
Huang, Ping-Hsiu; Lu, Hao-Te; Wang, Yuh-Tai; Wu, Ming-Chang
2011-09-14
The antioxidant activity of pectic enzyme treated pectin (PET-pectin) prepared from citrus pectin by enzymatic hydrolysis and its potential use as a stabilizer and an antioxidant for soy protein isolate (SPI)-stabilized oil in water (O/W) emulsion were investigated. Trolox equivalent antioxidant capacity (TEAC) was found to be positively associated with molecular weight (M(w)) of PET-pectin and negatively associated with degree of esterification (DE) of PET-pectin. PET-pectin (1 kDa and 11.6% DE) prepared from citrus pectin after 24 h of hydrolysis by commercial pectic enzyme produced by Aspergillus niger expressed higher α,α-diphenyl-β-picrylhydrazyl (DPPH) radical scavenging activity, TEAC, and reducing power than untreated citrus pectin (353 kDa and 60% DE). The addition of PET-pectin could increase both emulsifying activity (EA) and emulsion stability (ES) of SPI-stabilized O/W emulsion. When the SPI-stabilized lipid droplet was coated with the mixture of PET-pectin and pectin, the EA and ES of the emulsion were improved more than they were when the lipid droplet was coated with either pectin or PET-pectin alone. The amount of secondary oxidation products (thiobarbituric acid reactive substances) produced in the emulsion prepared with the mixture of SPI and PET-pectin was less than the amount produced in the emulsion prepared with either SPI or SPI/pectin. These results suggest that PET-pectin has an emulsion-stabilizing effect and lipid oxidation inhibition ability on SPI-stabilized emulsion. Therefore, PET-pectin can be used as a stabilizer as well as an antioxidant in plant origin in SPI-stabilized O/W emulsion and thus prolong the shelf life of food emulsion.
Heijtel, D F R; Mutsaerts, H J M M; Bakker, E; Schober, P; Stevens, M F; Petersen, E T; van Berckel, B N M; Majoie, C B L M; Booij, J; van Osch, M J P; Vanbavel, E; Boellaard, R; Lammertsma, A A; Nederveen, A J
2014-05-15
Measurements of the cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) provide useful information about cerebrovascular condition and regional metabolism. Pseudo-continuous arterial spin labeling (pCASL) is a promising non-invasive MRI technique to quantitatively measure the CBF, whereas additional hypercapnic pCASL measurements are currently showing great promise to quantitatively assess the CVR. However, the introduction of pCASL at a larger scale awaits further evaluation of the exact accuracy and precision compared to the gold standard. (15)O H₂O positron emission tomography (PET) is currently regarded as the most accurate and precise method to quantitatively measure both CBF and CVR, though it is one of the more invasive methods as well. In this study we therefore assessed the accuracy and precision of quantitative pCASL-based CBF and CVR measurements by performing a head-to-head comparison with (15)O H₂O PET, based on quantitative CBF measurements during baseline and hypercapnia. We demonstrate that pCASL CBF imaging is accurate during both baseline and hypercapnia with respect to (15)O H₂O PET with a comparable precision. These results pave the way for quantitative usage of pCASL MRI in both clinical and research settings. Copyright © 2014 Elsevier Inc. All rights reserved.
Stability of perovskite solar cells on flexible substrates
NASA Astrophysics Data System (ADS)
Tam, Ho Won; Chen, Wei; Liu, Fangzhou; He, Yanling; Leung, Tik Lun; Wang, Yushu; Wong, Man Kwong; Djurišić, Aleksandra B.; Ng, Alan Man Ching; He, Zhubing; Chan, Wai Kin; Tang, Jinyao
2018-02-01
Perovskite solar cells are emerging photovoltaic technology with potential for low cost, high efficiency devices. Currently, flexible devices efficiencies over 15% have been achieved. Flexible devices are of significant interest for achieving very low production cost via roll-to-roll processing. However, the stability of perovskite devices remains a significant challenge. Unlike glass substrate which has negligible water vapor transmission rate (WVTR), polymeric flexible film substrates suffer from high moisture permeability. As PET and PEN flexible substrates exhibit higher water permeability then glass, transparent flexible backside encapsulation should be used to maximize light harvesting in perovskite layer while WVTR should be low enough. Wide band gap materials are transparent in the visible spectral range low temperature processable and can be a moisture barrier. For flexible substrates, approaches like atomic layer deposition (ALD) and low temperature solution processing could be used for metal oxide deposition. In this work, ALD SnO2, TiO2, Al2O3 and solution processed spin-on-glass was used as the barrier layer on the polymeric side of indium tin oxide (ITO) coated PEN substrates. The UV-Vis transmission spectra of the prepared substrates were investigated. Perovskite solar cells will be fabricated and stability of the devices were encapsulated with copolymer films on the top side and tested under standard ISOS-L-1 protocol and then compared to the commercial unmodified ITO/PET or ITO/PEN substrates. In addition, devices with copolymer films laminated on both sides successfully surviving more than 300 hours upon continuous AM1.5G illumination were demonstrated.
Composites based on PET and red mud residues as catalyst for organic removal from water.
Bento, Natálya I; Santos, Patrícia S C; de Souza, Talita E; Oliveira, Luiz C A; Castro, Cínthia S
2016-08-15
In this study, we obtained a composite based on carbon/iron oxide from red mud and PET (poly(ethylene terephthalate)) wastes by mechanical mixture (10, 15 and 20wt.% of PET powder/red mud) followed by a controlled thermal treatment at 400°C under air. XRD analyses revealed that the α-Fe2O3 is the main phase formed from red mud. TPR analyses showed that the iron oxide present in the composites undergoes reduction at lower temperature to form Fe(2+) species present in Fe3O4, indicating that the iron oxide in the composite can exhibit greater reactivity in the catalytic processes compared to the original red mud. In fact, catalytic tests showed that the composites presented higher capacity to remove methylene blue dye (MB), presenting about 90% of removal after 24h of reaction. The MB removal was also monitored by mass spectrometer with ionization via electrospray (ESI-MS), which demonstrated the occurrence of the oxidation process, showing the formation of MB oxidation products. The stability of the composites was confirmed after four reuse cycles. The results seem to indicate that PET carbon deposited over the iron oxide from red mud promotes adsorption of the contaminant allowing its contact with the iron atoms and their consequent reaction. Copyright © 2016 Elsevier B.V. All rights reserved.
Dissociation of metabolic and hemodynamic levodopa responses in the 6-hydroxydopamine rat model.
Lerner, Renata P; Bimpisidis, Zisis; Agorastos, Stergiani; Scherrer, Sandra; Dewey, Stephen L; Cenci, M Angela; Eidelberg, David
2016-12-01
Dissociation of vasomotor and metabolic responses to levodopa has been observed in human subjects with Parkinson's disease (PD) studied with PET and in autoradiograms from 6-hydroxydopamine (6-OHDA) rat. In both species, acute levodopa administration was associated with increases in basal ganglia cerebral blood flow (CBF) with concurrent reductions in cerebral metabolic rate (CMR) for glucose in the same brain regions. In this study, we used a novel dual-tracer microPET technique to measure CBF and CMR levodopa responses in the same animal. Rats with unilateral 6-OHDA or sham lesion underwent sequential 15 O-water (H 2 15 O) and 18 F-fluorodeoxyglucose (FDG) microPET to map CBF and CMR following the injection of levodopa or saline. A subset of animals was separately scanned under ketamine/xylazine and isoflurane to compare the effects of these anesthetics. Regardless of anesthetic agent, 6-OHDA animals exhibited significant dissociation of vasomotor (ΔCBF) and metabolic (ΔCMR) responses to levodopa, with stereotyped increases in CBF and reductions in CMR in the basal ganglia ipsilateral to the dopamine lesion. No significant changes were seen in sham-lesioned animals. These data faithfully recapitulate analogous dissociation effects observed previously in human PD subjects scanned sequentially during levodopa infusion. This approach may have utility in the assessment of new drugs targeting the exaggerated regional vasomotor responses seen in human PD and in experimental models of levodopa-induced dyskinesia. Copyright © 2016 Elsevier Inc. All rights reserved.
Design and evaluation of radiotracers for determination of regional cerebral blood flow with PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambrecht, R.M.; Duncan, C.C.; Shiue, C.Y.
The tracer kinetics of 4-Fluoro(/sup 18/F)-, 4-Bromo(/sup 82/Br)- and 4-Iodo(/sup 125/I)-antipyrine and /sup 15/O-water were compared in a cat or baboon animal model. First-pass cerebral extraction and clearance with alterations in PaCO/sub 2/ were measured for whole brain. The Renkin/Crone model was used to evaluate brain capillary permeability-surface area product for 4-/sup 18/FAP in cats. Positron-emission-tomographic measurements required development of an instrument and technique for control of the arterial concentration of the radiotracer as a ramp function, so that tracer concentration changes due to radioactive decay or altered physiological processes could be accurately described with PET. Pharmacokinetic and tissue-distribution studiesmore » in cats were used to determine dosimetry for 4-/sup 18/FAP. 4-Bromoantipyrine labeled with /sup 78/Br (t = 6.5 m) is suggested as a tracer for determination of rCBF with PET.« less
Fierstra, Jorn; van Niftrik, Christiaan; Warnock, Geoffrey; Wegener, Susanne; Piccirelli, Marco; Pangalu, Athina; Esposito, Giuseppe; Valavanis, Antonios; Buck, Alfred; Luft, Andreas; Bozinov, Oliver; Regli, Luca
2018-03-01
Increased stroke risk correlates with hemodynamic failure, which can be assessed with ( 15 O-)H 2 O positron emission tomography (PET) cerebral blood flow (CBF) measurements. This gold standard technique, however, is not established for routine clinical imaging. Standardized blood oxygen-level-dependent (BOLD) functional magnetic resonance imaging+CO 2 is a noninvasive and potentially widely applicable tool to assess whole-brain quantitative cerebrovascular reactivity (CVR). We examined the agreement between the 2 imaging modalities and hypothesized that quantitative CVR can be a surrogate imaging marker to assess hemodynamic failure. Nineteen data sets of subjects with chronic cerebrovascular steno-occlusive disease (age, 60±11 years; 4 women) and unilaterally impaired perfusion reserve on Diamox-challenged ( 15 O-)H 2 O PET were studied and compared with a standardized BOLD functional magnetic resonance imaging+CO 2 examination within 6 weeks (8±19 days). Agreement between quantitative CBF- and CVR-based perfusion reserve was assessed. Hemodynamic failure was staged according to PET findings: stage 0: normal CBF, normal perfusion reserve; stage I: normal CBF, decreased perfusion reserve; and stage II: decreased CBF, decreased perfusion reserve. The BOLD CVR data set of the same subjects was then matched to the corresponding stage of hemodynamic failure. PET-based stage I versus stage II could also be clearly separated with BOLD CVR measurements (CVR for stage I 0.11 versus CVR for stage II -0.03; P <0.01). Hemispheric and middle cerebral artery territory difference analyses (ie, affected versus unaffected side) showed a significant correlation for CVR impairment in the affected hemisphere and middle cerebral artery territory ( P <0.01, R 2 =0.47 and P =0.02, R 2 = 0.25, respectively). BOLD CVR corresponded well to CBF perfusion reserve measurements obtained with ( 15 O-)H 2 O-PET, especially for detecting hemodynamic failure in the affected hemisphere and middle cerebral artery territory and for identifying hemodynamic failure stage II. BOLD CVR may, therefore, be considered for prospective studies assessing stroke risk in patients with chronic cerebrovascular steno-occlusive disease, in particular because it can potentially be implemented in routine clinical imaging. © 2018 American Heart Association, Inc.
Automatic, sterile, and apyrogenic delivery of PET radiotracers from the cyclotron to the patient
NASA Astrophysics Data System (ADS)
Votaw, J. R.; Cashion, D. B.; Clanton, J. A.
1991-05-01
An automatic delivery remote injection system has been developed to administer either 13N-labelled ammonia, or 15O-labelled water or 18F-labelled FDG to patients. Automation increases the throughout and efficiency of the PET center, and remote dose administration ensures patient safety and reduces the radiation exposure to the technologist supervising the radiopharmaceutical injection. The remote dose administration apparatus utilizes a syringe pump to transfer liquid activity and a solenoid three-way valve to switch between lines connected to a patient and a receiving vial. To ensure apyrogenicity and sterility of the injected product, the entire system is washed with sterile water before it is used. Since the tracer is delivered in an ~ 8 ml bolus of water, the next delivery through the system is considered safe for injection if pyrogens are not detected at a threshold of 3 endotoxin units per ml (EU/ml) in the wash. Time delayed tests shows that the system may be left unused for up to 6 h before the wash must be repeated.
NASA Astrophysics Data System (ADS)
Heredia-Munoz, Manuel Antonio
Water is perhaps the most important resource that sustains human life. According to the World Health Organization (WHO), almost two billion people do not have access to the required water that is needed to satisfy their daily needs and one billion do not have access to clean sources of water for consumption, most of them living in isolated and poor areas around the globe. Poor quality water increases the risk of cholera, typhoid fever and dysentery, and other water-borne illness making this problem a real crisis that humankind is facing. Several water disinfection technologies have been proposed as solutions for this problem. Solar water disinfection using TiO2 coated PET bottles was the alternative that is studied in this work. This technology does not only inactivate bacteria but also disintegrates organic chemicals that can be present in water. The objectives of this work address the optimization of the TiO 2 coated PET bottles technologies. The improvement on the bottle coating process, using two coats of 10% W/V of TiO2 in a solution of vinegar and sodium bicarbonate to form the TiO2 film, the use of a different indigo carmine (1.25 X 10-1mg/pill) concentration in the pill indicator of contamination, the increase of the disinfection rate through shaking the bottles, degradation under intermittent UV radiation and the effect of bottle size on photocatalytic water disinfection were among the most important findings. A new mathematical model that describes better photocatalytic water disinfection in TiO2 coated bottles and simulates water disinfection under different working conditions was another important achievement. These results can now be used to design a strategy for disseminating this technology in areas where it is required and, in that way, generate the greatest positive impact on the people needing safe drinking water.
Baller, Erica B.; Wei, Shau-Ming; Kohn, Philip D.; Rubinow, David R.; Alarcón, Gabriela; Schmidt, Peter J.; Berman, Karen F.
2014-01-01
Objective To investigate the neural substrate of premenstrual dysphoric disorder (PMDD), the authors used [15O]H2O positron emission tomography (PET) regional cerebral blood flow (rCBF) and blood-oxygen-level-dependent (BOLD) functional MRI (fMRI) signal measurements during working memory in conjunction with a 6-month hormone manipulation protocol. Method PET and fMRI scans were obtained from women with prospectively confirmed PMDD and asymptomatic comparison subjects while they completed the n-back task during three hormone conditions: ovarian suppression induced by the gonadotropin-releasing hormone agonist leuprolide acetate, leuprolide plus estradiol, and leuprolide plus progesterone. Fifteen patients and 15 matched comparison subjects underwent PET imaging. Fourteen patients and 14 comparison subjects underwent fMRI. For each hormone condition, rCBF was measured with [15O]H2O PET, and BOLD signal was measured with fMRI, both during an n-back working memory paradigm. Global Assessment of Functioning Scale (GAF) scores and clinical characteristics were obtained for each patient before hormone manipulation, and symptoms were measured before and during the protocol. Results In both the PET and fMRI studies, a main effect of diagnosis was observed, with PMDD patients showing greater prefrontal activation than comparison subjects. In the patient group, the degree to which dorsolateral prefrontal cortex activation was abnormally increased correlated with several dimensions of disease: disability as indicated by GAF scores, age at symptom onset, duration of PMDD, and differences in pre- and postmenses PMDD symptoms. Conclusions Abnormal working memory activation in PMDD, specifically in the dorsolateral prefrontal cortex, is related to PMDD severity, symptoms, age at onset, and disease burden. These results support the clinical relevance of the findings and the proposal that dorsolateral prefrontal cortex dysfunction represents a substrate of risk for PMDD. The concordance of the fMRI and PET data attests to the neurobiological validity of the results. PMID:23361612
Baller, Erica B; Wei, Shau-Ming; Kohn, Philip D; Rubinow, David R; Alarcón, Gabriela; Schmidt, Peter J; Berman, Karen F
2013-03-01
To investigate the neural substrate of premenstrual dysphoric disorder (PMDD), the authors used [15O]H2O positron emission tomography (PET) regional cerebral blood flow (rCBF) and blood-oxygen-level-dependent (BOLD) functional MRI (fMRI) signal measurements during working memory in conjunction with a 6-month hormone manipulation protocol. PET and fMRI scans were obtained from women with prospectively confirmed PMDD and asymptomatic comparison subjects while they completed the n-back task during three hormone conditions: ovarian suppression induced by the gonadotropin-releasing hormone agonist leuprolide acetate, leuprolide plus estradiol, and leuprolide plus progesterone. Fifteen patients and 15 matched comparison subjects underwent PET imaging. Fourteen patients and 14 comparison subjects underwent fMRI. For each hormone condition, rCBF was measured with [15O]H2O PET, and BOLD signal was measured with fMRI, both during an n-back working memory paradigm. Global Assessment of Functioning Scale (GAF) scores and clinical characteristics were obtained for each patient before hormone manipulation, and symptoms were measured before and during the protocol. In both the PET and fMRI studies, a main effect of diagnosis was observed, with PMDD patients showing greater prefrontal activation than comparison subjects. In the patient group, the degree to which dorsolateral prefrontal cortex activation was abnormally increased correlated with several dimensions of disease: disability as indicated by GAF scores, age at symptom onset, duration of PMDD, and differences in pre- and postmenses PMDD symptoms. Abnormal working memory activation in PMDD, specifically in the dorsolateral prefrontal cortex, is related to PMDD severity, symptoms, age at onset, and disease burden. These results support the clinical relevance of the findings and the proposal that dorsolateral prefrontal cortex dysfunction represents a substrate of risk for PMDD. The concordance of the fMRI and PET data attests to the neurobiological validity of the results.
Ishiwata, Kiichi; Hayashi, Kunpei; Sakai, Masanari; Kawauchi, Sugio; Hasegawa, Hideaki; Toyohara, Jun
2017-01-01
To elucidate the radionuclides and radiochemical impurities included in radiosynthesis processes of positron emission tomography (PET) tracers. Target materials and PET tracers were produced using a cyclotron/synthesis system from Sumitomo Heavy Industry. Positron and γ-ray emitting radionuclides were quantified by measuring radioactivity decay and using the high-purity Ge detector, respectively. Radiochemical species in gaseous and aqueous target materials were analyzed by gas and ion chromatography, respectively. Target materials had considerable levels of several positron emitters in addition to the positron of interest, and in the case of aqueous target materials extremely low levels of many γ-emitters. Five 11 C-, 15 O-, or 18 F-labeled tracers produced from gaseous materials via chemical reactions had no radionuclidic impurities, whereas 18 F-FDG, 18 F-NaF, and 13 N-NH 3 produced from aqueous materials had several γ-emitters as well as impure positron emitters. 15 O-Labeled CO 2 , O 2 , and CO had a radionuclidic impurity 13 N-N 2 (0.5-0.7 %). Target materials had several positron emitters other than the positron of interest, and extremely low level γ-emitters in the case of aqueous materials. PET tracers produced from gaseous materials except for 15 O-labeled gases had no impure radionuclides, whereas those derived from aqueous materials contained acceptable levels of impure positron emitters and extremely low levels of several γ-emitters.
Bubble column and CFD simulation for chemical recycling of polyethylene terephthalate
NASA Astrophysics Data System (ADS)
Alzuhairi, Mohammed
2018-05-01
Computational Fluid Dynamics (CFD) is an important simulation tool, which uses powerful computer to get optimal design in industrial processes. New approach technique of bubble column for three phases has been used with respect to chemical recycling of Polyethylene Terephthalate (PET). The porous ceramic has been used in thin plate (5 mm) with a narrow pore size distribution. Excellent agreement between CFD has been predicted and experimental profiles of hold-up and velocity close to wall have been observed for a column diameter 0.08 m, column height 0.15 m (HD), and superficial gas velocity (VG) 0.05 m/s. The main purpose of the current study is to highlight depolymerization of PET chemically by using the close system of Ethylene Glycol, PET-Catalyzed, and Nitrogen glycolysis process in bubble column of three phases technique by using Nano catalyst, SiO2 with various weight percent (0.01, 0.02, 0.05, 0.1, 0.2, and 0.5) based on PET weight and preheated Nitrogen up to 100° C by extra heater in bubble column reactor. The depolymerization time could be reduced in order to improve heat and mass transfer in comparison with the traditional methods. Little amount not exceeding 0.01% of Nano SiO2 is enough for completing depolymerization. The final product of PET depolymerization has full characterization by FTIR, AFM, CHN tests and has been used as a vital additive for Bitumen, it has been investigated as a moisture-proof, water seepage-proof material, and as a tough resistant to environmental conditions.
Glycoalkaloid content in pet food by UPLC-tandem mass spectrometry.
Sheridan, Robert S; Kemnah, Jennifer L
2010-11-01
The glycoalkaloid content of pet food containing potatoes is investigated using a liquid-liquid solvent extraction followed by analysis by ultra-high pressure liquid chromatography tandem mass spectrometry (UPLC-MS-MS). Pet food samples are homogenized and extracted with a solution of 50:50 (v/v) acetonitrile-deionized water containing 5% acetic acid. Following vortexing and centrifugation, 3 mL of the supernatant is filtered and diluted in deionized water. The extract is injected onto a reverse phase C18 UPLC column with an initial mobile phase composed of 0.15% acetic acid in water (A) and 0.15% acetic acid in methanol (B) in a ratio of 70:30, respectively. The mobile phase reaches a final concentration of 15% A and 85% B over 10 min, at which point it is returned to the initial conditions. α-Solanine is measured by monitoring transitions m/z = 868.50 → 398.40 and 868.50 → 722.50, while α-chaconine is measure by monitoring transitions m/z = 852.60 → 97.80 and 852.60 → 706.50. Each analyte is measured and combined to determine total glycoalkaloid content (TGA). The results of the analysis of 52 pet food samples indicate both glycoalkaloids are present in all samples and two pet foods were found to contain > 100 μg/g total glycoalkaloid.
Preparation and dyeing of super hydrophilic polyethylene terephthalate fabric
NASA Astrophysics Data System (ADS)
Zheng, D. D.; Zhou, J. F.; Xu, F.; Zhang, F. X.; Zhang, G. X.
2016-07-01
In this study, the dyeing properties of PET fabrics modified with sulfuric acid was investigated using disperse red E-4B and disperse blue 2BLNG-L at high temperature and high pressure. The results revealed that the sulfuric acid modification improved the K/S value of dyeing PET fabrics, and the modified PET fabric could be dyed uniformly. The a, b, C, L and H of modified PET fabric were almost the same as that of original PET fabric. The water contact angles were still 0o after 10s, indicating that the hydrophilic property of modified PET fabrics still kept excellent. The wash fastness of dyed PET fabrics after modification was generally good.
NASA Astrophysics Data System (ADS)
Janek, S.; Svensson, R.; Jonsson, C.; Brahme, A.
2006-11-01
A method for dose delivery monitoring after high energy photon therapy has been investigated based on positron emission tomography (PET). The technique is based on the activation of body tissues by high energy bremsstrahlung beams, preferably with energies well above 20 MeV, resulting primarily in 11C and 15O but also 13N, all positron-emitting radionuclides produced by photoneutron reactions in the nuclei of 12C, 16O and 14N. A PMMA phantom and animal tissue, a frozen hind leg of a pig, were irradiated to 10 Gy and the induced positron activity distributions were measured off-line in a PET camera a couple of minutes after irradiation. The accelerator used was a Racetrack Microtron at the Karolinska University Hospital using 50 MV scanned photon beams. From photonuclear cross-section data integrated over the 50 MV photon fluence spectrum the predicted PET signal was calculated and compared with experimental measurements. Since measured PET images change with time post irradiation, as a result of the different decay times of the radionuclides, the signals from activated 12C, 16O and 14N within the irradiated volume could be separated from each other. Most information is obtained from the carbon and oxygen radionuclides which are the most abundant elements in soft tissue. The predicted and measured overall positron activities are almost equal (-3%) while the predicted activity originating from nitrogen is overestimated by almost a factor of two, possibly due to experimental noise. Based on the results obtained in this first feasibility study the great value of a combined radiotherapy-PET-CT unit is indicated in order to fully exploit the high activity signal from oxygen immediately after treatment and to avoid patient repositioning. With an RT-PET-CT unit a high signal could be collected even at a dose level of 2 Gy and the acquisition time for the PET could be reduced considerably. Real patient dose delivery verification by means of PET imaging seems to be applicable provided that biological transport processes such as capillary blood flow containing mobile 15O and 11C in the activated tissue volume can be accounted for.
NASA Astrophysics Data System (ADS)
Lüdemann, L.; Sreenivasa, G.; Michel, R.; Rosner, C.; Plotkin, M.; Felix, R.; Wust, P.; Amthauer, H.
2006-06-01
Assessment of perfusion with 15O-labelled water (H215O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF.
Franz, Roland; Gmeiner, Margit; Gruner, Anita; Kemmer, Diana; Welle, Frank
2016-01-01
ABSTRACT Polyethylene terephthalate (PET) bottles are widely used as packaging material for natural mineral water. However, trace levels of acetaldehyde can migrate into natural mineral water during the shelf life and might influence the taste of the PET bottled water. 2-Aminobenzamide is widely used during PET bottle production as a scavenging agent for acetaldehyde. The aim of this study was the determination of the migration kinetics of 2-aminobenzamide into natural mineral water as well as into 20% ethanol. From the migration kinetics, the diffusion coefficients of 2-aminobenzamide in PET at 23 and 40°C were determined to be 4.2 × 10− 16 and 4.2 × 10− 15 cm2 s–1, respectively. The diffusion coefficient for 20% ethanol at 40°C was determined to be 7.7 × 10− 15 cm2 s–1, which indicates that 20% ethanol is causing swelling of the PET polymer. From a comparison of migration values between 23 and 40°C, acceleration factors of 9.7 when using water as contact medium and 18.1 for 20% ethanol as simulant can be derived for definition of appropriate accelerated test conditions at 40°C. The European Union regulatory acceleration test based on 80 kJ mol–1 as conservative activation energy overestimates the experimentally determined acceleration rates by a factor of 1.6 and 3.1, respectively. PMID:26666986
Kageyama, Hiroyuki; Morita, Koichi; Katoh, Chietsugu; Tsukamoto, Takahiro; Noriyasu, Kazuyuki; Mabuchi, Megumi; Naya, Masanao; Kawai, Yuko; Tamaki, Nagara
2006-01-01
Long-chain fatty acid (LCFA) is the main energy source for normal myocardium at rest, but in ischemic myocardium, the main energy substrate shifts from LCFA to glucose. 123I-BMIPP is a radiolabeled LCFA analog. In chronic stable angina without previous infarction, we suppose that reduced 123I-BMIPP uptake is related to the substrate shift in myocardium with decreased myocardial flow reserve (MFR). The purpose of this study was to relate 123I-BMIPP uptake to rest myocardial blood flow (MBF), hyperemic MBF, and MFR assessed with 15O-water positron emission tomography (PET). We enrolled 21 patients with chronic stable angina without previous infarction, all of whom underwent 123I-BMIPP single-photon emission computed tomography (SPECT) and 15O-water PET. The left ventricle was divided into 13 segments. In each segment, rest MBF and hyperemic MBF were measured by PET. 123I-BMIPP uptake was evaluated as follows: score 0=normal, 1=slightly decreased uptake, 2=moderately decreased uptake, 3=severely decreased uptake, and 4=complete defect. 123I-BMIPP uptake was compared with rest MBF, hyperemic MBF, and MFR. The numbers of segments with 123I-BMIPP scores 0, 1, 2, 3, and 4 were 178, 40, 25, 24, and 0, respectively. The rest MBFs for scores 0, 1, 2, and 3 were 0.93+/-0.25, 0.86+/-0.21, 0.97+/-0.30, and 0.99+/-0.37 ml/min/g, respectively. The hyperemic MBFs for scores 0, 1, 2, and 3 were 2.76+/-1.29, 1.84+/-0.74, 1.37+/-0.39, and 1.08+/-0.40 ml/min/g, respectively. The MFRs for scores 0, 1, 2, and 3 were 3.01+/-1.38, 2.20+/-0.95, 1.44+/-0.22, and 1.10+/-0.26, respectively. As 123I-BMIPP uptake declined, hyperemic MBF and MFR decreased. In chronic stable angina without previous infarction, reduced 123I-BMIPP uptake implies decreased MFR.
Miyamoto, J; Tatsuzawa, K; Inoue, Y; Imahori, Y; Mineura, K
2007-09-01
The present study revealed the changes in cerebral oxygen metabolism before and after ventriculo-peritoneal shunt (VPS) using (15)O positron emission tomography ((15)O-PET). Eight patients with idiopathic normal pressure hydrocephalus (i-NPH) underwent VPS. A (15)O-PET study was undertaken before and approximately 3 months after VPS. In five patients, the symptoms improved based on the classification by Krauss et al. [Neurosurgery 1996;39:292] (good responders) after VPS. In three patients, the symptoms improved subjectively following VPS (poor responders). The changes in oxygen metabolism before and after VPS were analyzed. The postoperative regional cerebral metabolic rate of oxygen (rCMRO(2)) of the good responders increased significantly. The postoperative regional oxygen extraction fraction (rOEF) is reduced in the poor responders. The improvement of rCMRO(2) correlated with the response to VPS. Significant changes in rOEF might predict poor response to VPS.
Life cycle assessment of bottled water: A case study of Green2O products.
Horowitz, Naomi; Frago, Jessica; Mu, Dongyan
2018-06-01
This study conducted a full life cycle analysis of bottled water on four types of bottles: ENSO, PLA (corn based), recycled PET, and regular (petroleum based) PET, to discern which bottle material is more beneficial to use in terms of environmental impacts. PET bottles are the conventional bottles used that are not biodegradable and accumulate in landfills. PLA corn based bottles are derived from an organic substance and are degradable under certain environmental conditions. Recycled PET bottles are purified PET bottles that were disposed of and are used in a closed loop system. An ENSO bottle contains a special additive which is designed to help the plastic bottle degrade after disposed of in a landfill. The results showed that of all fourteen impact categories examined, the recycled PET and ENSO bottles were generally better than the PLA and regular PET bottles; however, the ENSO had the highest impacts in the categories of global warming and respiratory organics, and the recycled PET had the highest impact in the eutrophication category. The life cycle stages that were found to have the highest environmental impacts were the bottle manufacturing stage and the bottled water distribution to storage stage. Analysis of the mixed bottle material based on recycled PET resin and regular PET resin was discussed as well, in which key impact categories were identified. The PLA bottle contained extremely low impacts in the carcinogens, respiratory organics and global warming categories, yet it still contained the highest impacts in seven of the fourteen categories. Overall, the results demonstrate that the usage of more sustainable bottles, such as biodegradable ENSO bottles and recycled PET bottles, appears to be a viable option for decreasing impacts of the bottled water industry on the environment. Published by Elsevier Ltd.
O'Sullivan, Finbarr; Muzi, Mark; Mankoff, David A; Eary, Janet F; Spence, Alexander M; Krohn, Kenneth A
2014-06-01
Most radiotracers used in dynamic positron emission tomography (PET) scanning act in a linear time-invariant fashion so that the measured time-course data are a convolution between the time course of the tracer in the arterial supply and the local tissue impulse response, known as the tissue residue function. In statistical terms the residue is a life table for the transit time of injected radiotracer atoms. The residue provides a description of the tracer kinetic information measurable by a dynamic PET scan. Decomposition of the residue function allows separation of rapid vascular kinetics from slower blood-tissue exchanges and tissue retention. For voxel-level analysis, we propose that residues be modeled by mixtures of nonparametrically derived basis residues obtained by segmentation of the full data volume. Spatial and temporal aspects of diagnostics associated with voxel-level model fitting are emphasized. Illustrative examples, some involving cancer imaging studies, are presented. Data from cerebral PET scanning with 18 F fluoro-deoxyglucose (FDG) and 15 O water (H2O) in normal subjects is used to evaluate the approach. Cross-validation is used to make regional comparisons between residues estimated using adaptive mixture models with more conventional compartmental modeling techniques. Simulations studies are used to theoretically examine mean square error performance and to explore the benefit of voxel-level analysis when the primary interest is a statistical summary of regional kinetics. The work highlights the contribution that multivariate analysis tools and life-table concepts can make in the recovery of local metabolic information from dynamic PET studies, particularly ones in which the assumptions of compartmental-like models, with residues that are sums of exponentials, might not be certain.
NASA Astrophysics Data System (ADS)
Han, Jin-Woo; Kang, Hee-Jin; Kim, Jong-Yeon; Kim, Gwi-Yeol; Seo, Dae-Shik
2006-12-01
In this study, inorganic multilayer thin-film encapsulation is adopted for the first time to protect an organic layer from moisture and oxygen. Inorganic multilayer thin-film encapsulation is deposited onto poly(ethylene terephthalate) (PET) using an electron beam and sputtering. The SiON/SiO2 and parylene layer show the most suitable properties. Under these conditions, the water vapor transmission rate (WVTR) for PET can be reduced from a level of 0.57 g m-2 day-1 (bare substrate) to 1× 10-5 g m-2 day-1 after the application of a SiON and SiO2 layer. These results indicate that PET/parylene/SiO2/SiON barrier coatings have high potential for flexible organic light-emitting diode (OLED) applications.
NASA Astrophysics Data System (ADS)
Streher, A. S.; Sobreiro, J. F. F.; Silva, T. S. F.
2017-12-01
Water availability is one of the main drivers of vegetation distribution, but assessing it over mountainous regions is difficult given the effects of rugged topography on hydroclimatic dynamics (orographic rainfall, soil water, and runoff). We assessed how water availability may influence the distribution of vegetation types in the Espinhaço Range, a South American tropical mountain landscape comprised of savannas, grasslands, rock outcrops, cloud forests, and semi-deciduous/deciduous forests. For precipitation, we used CHIRPS monthly and daily products (1981- 2016) and 112 rain gauge ground stations, and assessed potential evapotranspiration (PET) using the MODIS MOD16A3 (2000-2013) product. Vegetation types were classified according to the Global Ecoregions by WWF. We show that rainfall has well-defined rainy and dry seasons with a strong latitudinal pattern, there is evidence for local orographic effects. Dry forests (907 mm/yr; 8% cv) and caatinga vegetation (795 mm/yr; 7% cv) had the lowest average annual precipitation and low variance, whilst Atlantic tropical forest in the southeast (1267 mm/yr; 15% cv), cerrado savanna vegetation in the west (1086 mm/yr; 15% cv) and rupestrian grasslands above 800m (1261 mm/yr; 20% cv) received the highest annual precipitation, with the largest observed variance due to their wide latitudinal distribution. Forests and rupestrian grasslands in the windward side of the mountain had a higher frequency of intense rainfall events (> 20mm), accounting for 6% of the CHIRPS daily time series, suggesting orographic effects on precipitation. Annual average PET was highest for dry forests (2437 mm/yr) and caatinga (2461 mm/yr), intermediate for cerrado (2264 mm/yr) and lowest for Atlantic tropical forest (2083 mm/yr) and rupestrian grasslands (2136 mm/yr). All vegetation types received less rainfall than its PET capacity based on yearly data, emphasizing the need for ecophysiological adaptations to water use. Climate change threatens these ecosystems by possible alterations on the hydrological cycle and, consequently, capacity for adaptations on water use. These could lead to shifts in vegetation composition and distribution within the studied region. Further investigation of seasonal trends on water availability and edaphic factors would improve these analyses.
Kikuchi, Yasuka; Oyama-Manabe, Noriko; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Sasaki, Tsukasa; Katoh, Chietsugu; Kudo, Kohsuke; Tamaki, Nagara; Shirato, Hiroki
2014-07-01
This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.
Study on the leaching of phthalates from polyethylene terephthalate bottles into mineral water.
Keresztes, Szilvia; Tatár, Enikő; Czégény, Zsuzsanna; Záray, Gyula; Mihucz, Victor G
2013-08-01
Carbonated and non-carbonated mineral water samples bottled in 0.5-L, 1.5-L and 2.0-L polyethylene terephthalate (PET) containers belonging to three different water brands commercialized in Hungary were studied in order to determine their phthalate content by gas chromatography-mass spectrometry. Among the six investigated phthalates, diisobutyl phthalate, di-n-butyl-phthalate, benzyl-butyl phthalate and di(2-ethyl-hexyl) phthalate (DEHP) were determined in non-carbonated samples as follows: <3.0 ng L(-1)-0.2 μg L(-1), <6.6 ng L(-1)-0.8 μg L(-1), <6.0 ng L(-1)-0.1 μg L(-1) and <16.0 ng L(-1)-1.7 μg L(-1), respectively. Any of the above-mentioned phthalate esters could be detected in carbonated mineral water samples. DEHP was the most abundant phthalate in the investigated samples. It could be detected after 44 days of storage at 22 °C and its leaching was the most pronounced when samples were stored over 1200 days. Mineral water purchased in PET bottles of 0.5L had the highest phthalate concentrations compared to those obtained for waters of the identical brand bottled in 1.5-L or 2.0-L PET containers due to the higher surface/volume ratio. No clear trend could be established for phthalate leaching when water samples were kept at higher temperatures (max. 60 °C) showing improper storage conditions. Phthalate determination by pyrolysis-gas chromatography/mass spectrometric measurements in the plastic material as well as in the aqueous phase proved the importance of the quality of PET raw material used for the production of the pre-form (virgin vs. polymer containing recycled PET). Copyright © 2013 Elsevier B.V. All rights reserved.
Murray, G L; Schad, N C; Magill, H L; Vander Zwaag, R
1994-04-01
Aggressive cardiac revascularization requires recognition of stunned and hibernating myocardium, and cost considerations may well govern the technique used. Dynamic low-dose (1 mCi) [123I]iodophenylpentadecanoic acid (IPPA) metabolic imaging is a potential alternative to PET using either 18FDG or 15O-water. Resting IPPA images were obtained from patients with severe ischemic cardiomyopathy, and transmural myocardial biopsies were obtained during coronary bypass surgery to confirm viability. Thirty-nine of 43 (91%) biopsies confirmed the results of the IPPA images with a sensitivity for viability of 33/36 (92%) and a specificity of 6/7 (86%). Postoperatively, wall motion improved in 80% of IPPA-viable, dysfunctional segments. Furthermore, when compared to reinjection thallium (SPECT-TI) scans after myocardial infarction, IPPA-SPECT-TI concordance occurred in 27/35 (77%) (K = 0.536, p = 0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-TI, 26/35 (74%) versus 18/35 (51%) (p = 0.047). Metabolic IPPA cardiac viability imaging is a safe, inexpensive technique that may be a useful alternative to PET.
Compartmental analysis of washout effect in rat brain: in-beam OpenPET measurement using a 11C beam
NASA Astrophysics Data System (ADS)
Hirano, Yoshiyuki; Kinouchi, Shoko; Ikoma, Yoko; Yoshida, Eiji; Wakizaka, Hidekazu; Ito, Hiroshi; Yamaya, Taiga
2013-12-01
In-beam positron emission tomography (PET) is expected to enable visualization of a dose verification using positron emitters (β+ decay). For accurate dose verification, correction of the washout of the positron emitters should be made. In addition, the quantitative washout rate has a potential usefulness as a diagnostic index, but modeling for this has not been studied yet. In this paper, therefore, we applied compartment analyses to in-beam PET data acquired by our small OpenPET prototype, which has a physically opened field-of-view (FOV) between two detector rings. A rat brain was located at the FOV and was irradiated by a 11C beam. Time activity curves of the irradiated field were measured immediately after the irradiations, and the washout rate was obtained based on two models: the two-washout model (medium decay, k2m; slow decay, k2s) developed in a study of rabbit irradiation; and the two-compartment model used in nuclear medicine, where efflux from tissue to blood (k2), influx (k3) and efflux (k4) from the first to second compartments in tissue were evaluated. The observed k2m and k2s were 0.34 and 0.005 min-1, respectively, which was consistent with the rabbit study. Also k2m was close to the washout rate in cerebral blood flow (CBF) measurements by dynamic PET with 15O-water, while, k2, k3, and k4 were 0.16, 0.15 and 0.007 min-1. Our present work suggested the dynamics of 11C might be relevant to CBF or permeability of a molecule containing 11C atoms might be regulated by a transporter because the k2 was relatively low compared with a simple diffusion tracer.
Physical properties of ZrC/Al2O3 imbedded heat storage woven fabrics
NASA Astrophysics Data System (ADS)
Kim, S. J.; Song, M. K.; Seo, K. O.; Kim, H. A.
2017-10-01
This study investigated different physical properties of ZrC/Al2O3 imbedded heat storage woven fabrics. ZrC and Al2O3 imbedded heat storage PET filaments were spun on the pilot spinning equipment, respectively. Various physical properties of ceramic imbedded fabrics made of ZrC and Al2O3 imbedded filaments were measured and compared with those of the regular PET woven fabric. The surface temperatures of the ZrC and Al2O3 imbedded fabrics were higher than that of the regular fabric. Water absorption rate of ceramic imbedded fabrics was better than that of the regular fabric and drying property was inferior to that of regular fabric. Breathability by water vapour resistance(Ref) of ZrC imbedded fabric was superior to that of regular fabric. Heat keepability rates of the ceramic imbedded fabrics were higher than that of the regular fabrics, which revealed a good heat storage property of the ZrC/Al2O3 imbedded fabrics.
NASA Astrophysics Data System (ADS)
Wang, Wei; Ai, Taotao; Yu, Qi
2017-02-01
Boron-doped zinc oxide sheet-spheres were synthesized on PET-ITO flexible substrates using a hydrothermal method at 90 °C for 5 h. The results of X-ray diffraction and X-ray photoelectron spectroscopy indicated that the B atoms were successfully doped into the ZnO lattice, the incorporation of B led to an increase in the lattice constant of ZnO and a change in its internal stress. The growth mechanism of pure ZnO nanorods and B-doped ZnO sheet-spheres was specifically investigated. The as-prepared BZO/PET-ITO heterojunction possessed obvious rectification properties and its positive turn-on voltage was 0.4 V. The carrier transport mechanisms involved three models such as hot carrier tunneling theory, tunneling recombination, and series-resistance effect were explored. The BZO/PET-ITO nanostructures were more effective than pure ZnO to degrade the RY 15, and the degradation rate reached 41.45%. The decomposition process with BZO nanostructure followed first-order reaction kinetics. The photocurrent and electrochemical impedance spectroscopy revealed that the B-doping could promote the separation of photo-generated electron-hole pairs, which was beneficial to enhance the photocatalytic activity. The photocurrent density of B-doped and pure ZnO/PET-ITO were 0.055 mA/cm2 and 0.016 mA/cm2, respectively. The photocatalytic mechanism of the sample was analyzed by the energy band theory.
The role of PET quantification in cardiovascular imaging.
Slomka, Piotr; Berman, Daniel S; Alexanderson, Erick; Germano, Guido
2014-08-01
Positron Emission Tomography (PET) has several clinical and research applications in cardiovascular imaging. Myocardial perfusion imaging with PET allows accurate global and regional measurements of myocardial perfusion, myocardial blood flow and function at stress and rest in one exam. Simultaneous assessment of function and perfusion by PET with quantitative software is currently the routine practice. Combination of ejection fraction reserve with perfusion information may improve the identification of severe disease. The myocardial viability can be estimated by quantitative comparison of fluorodeoxyglucose ( 18 FDG) and rest perfusion imaging. The myocardial blood flow and coronary flow reserve measurements are becoming routinely included in the clinical assessment due to enhanced dynamic imaging capabilities of the latest PET/CT scanners. Absolute flow measurements allow evaluation of the coronary microvascular dysfunction and provide additional prognostic and diagnostic information for coronary disease. Standard quantitative approaches to compute myocardial blood flow from kinetic PET data in automated and rapid fashion have been developed for 13 N-ammonia, 15 O-water and 82 Rb radiotracers. The agreement between software methods available for such analysis is excellent. Relative quantification of 82 Rb PET myocardial perfusion, based on comparisons to normal databases, demonstrates high performance for the detection of obstructive coronary disease. New tracers, such as 18 F-flurpiridaz may allow further improvements in the disease detection. Computerized analysis of perfusion at stress and rest reduces the variability of the assessment as compared to visual analysis. PET quantification can be enhanced by precise coregistration with CT angiography. In emerging clinical applications, the potential to identify vulnerable plaques by quantification of atherosclerotic plaque uptake of 18 FDG and 18 F-sodium fluoride tracers in carotids, aorta and coronary arteries has been demonstrated.
Yao, Rutao; Ramachandra, Ranjith M.; Mahajan, Neeraj; Rathod, Vinay; Gunasekar, Noel; Panse, Ashish; Ma, Tianyu; Jian, Yiqiang; Yan, Jianhua; Carson, Richard E.
2012-01-01
To achieve optimal PET image reconstruction through better system modeling, we developed a system matrix that is based on the probability density function for each line of response (LOR-PDF). The LOR-PDFs are grouped by LOR-to-detector incident angles to form a highly compact system matrix. The system matrix was implemented in the MOLAR list mode reconstruction algorithm for a small animal PET scanner. The impact of LOR-PDF on reconstructed image quality was assessed qualitatively as well as quantitatively in terms of contrast recovery coefficient (CRC) and coefficient of variance (COV), and its performance was compared with a fixed Gaussian (iso-Gaussian) line spread function. The LOR-PDFs of 3 coincidence signal emitting sources, 1) ideal positron emitter that emits perfect back-to-back γ rays (γγ) in air; 2) fluorine-18 (18F) nuclide in water; and 3) oxygen-15 (15O) nuclide in water, were derived, and assessed with simulated and experimental phantom data. The derived LOR-PDFs showed anisotropic and asymmetric characteristics dependent on LOR-detector angle, coincidence emitting source, and the medium, consistent with common PET physical principles. The comparison of the iso-Gaussian function and LOR-PDF showed that: 1) without positron range and acolinearity effects, the LOR-PDF achieved better or similar trade-offs of contrast recovery and noise for objects of 4-mm radius or larger, and this advantage extended to smaller objects (e.g. 2-mm radius sphere, 0.6-mm radius hot-rods) at higher iteration numbers; and 2) with positron range and acolinearity effects, the iso-Gaussian achieved similar or better resolution recovery depending on the significance of positron range effect. We conclude that the 3-D LOR-PDF approach is an effective method to generate an accurate and compact system matrix. However, when used directly in expectation-maximization based list-mode iterative reconstruction algorithms such as MOLAR, its superiority is not clear. For this application, using an iso-Gaussian function in MOLAR is a simple but effective technique for PET reconstruction. PMID:23032702
Murray, Louis C.
2009-01-01
Water-use data collected between 1992 and 2006 at eight municipal water-supply utilities in east-central and northeast Florida were analyzed to identify seasonal trends in use and to quantify monthly variations. Regression analyses were applied to identify significant correlations between water use and selected meteorological parameters and drought indices. Selected parameters and indices include precipitation (P), air temperature (T), potential evapotranspiration (PET), available water (P-PET), monthly changes in these parameters (Delta P, Delta T, Delta PET, Delta(P-PET), the Palmer Drought Severity Index (PDSI), and the Standardized Precipitation Index (SPI). Selected utilities include the City of Daytona Beach (Daytona), the City of Eustis (Eustis), Gainesville Regional Utilities (GRU), Jacksonville Electric Authority (JEA), Orange County Utilities (OCU), Orlando Utilities Commission (OUC), Seminole County Utilities (SCU), and the City of St. Augustine (St. Augustine). Water-use rates at these utilities in 2006 ranged from about 3.2 million gallons per day at Eustis to about 131 million gallons per day at JEA. Total water-use rates increased at all utilities throughout the 15-year period of record, ranging from about 4 percent at Daytona to greater than 200 percent at OCU and SCU. Metered rates, however, decreased at six of the eight utilities, ranging from about 2 percent at OCU and OUC to about 17 percent at Eustis. Decreases in metered rates occurred because the number of metered connections increased at a greater rate than did total water use, suggesting that factors other than just population growth may play important roles in water-use dynamics. Given the absence of a concurrent trend in precipitation, these decreases can likely be attributed to changes in non-climatic factors such as water-use type, usage of reclaimed water, water-use restrictions, demographics, and so forth. When averaged for the eight utilities, metered water-use rates depict a clear seasonal pattern in which rates were lowest in the winter and greatest in the late spring. Averaged water-use rates ranged from about 9 percent below the 15-year daily mean in January to about 11 percent above the daily mean in May. Water-use rates were found to be statistically correlated to meteorological parameters and drought indices, and to be influenced by system memory. Metered rates (in gallons per day per active metered connection) were consistently found to be influenced by P, T, PET, and P-PET and changes in these parameters that occurred in prior months. In the single-variant analyses, best correlations were obtained by fitting polynomial functions to plots of metered rates versus moving-averaged values of selected parameters (R2 values greater than 0.50 at three of eight sites). Overall, metered water-use rates were best correlated with the 3- to 4-month moving average of Delta T or Delta PET (R2 values up to 0.66), whereas the full suite of meteorological parameters was best correlated with metered rates at Daytona and least correlated with rates at St. Augustine. Similarly, metered rates were substantially better correlated with moving-averaged values of precipitation (significant at all eight sites) than with single (current) monthly values (significant at only three sites). Total and metered water-use rates were positively correlated with T, PET, Delta P, Delta T, and Delta PET, and negatively correlated with P, P-PET, Delta (P-PET), PDSI, and SPI. The drought indices were better correlated with total water-use rates than with metered rates, whereas metered rates were better correlated with meteorological parameters. Multivariant analyses produced fits of the data that explained a greater degree of the variance in metered rates than did the single-variant analyses. Adjusted R2 values for the 'best' models ranged from 0.79 at JEA to 0.29 at St. Augustine and exceeded 0.60 at five of eight sites. The amount of available water (P-PET) was the si
Atomically monodisperse nickel nanoclusters as highly active electrocatalysts for water oxidation
NASA Astrophysics Data System (ADS)
Joya, Khurram S.; Sinatra, Lutfan; Abdulhalim, Lina G.; Joshi, Chakra P.; Hedhili, M. N.; Bakr, Osman M.; Hussain, Irshad
2016-05-01
Achieving water splitting at low overpotential with high oxygen evolution efficiency and stability is important for realizing solar to chemical energy conversion devices. Herein we report the synthesis, characterization and electrochemical evaluation of highly active nickel nanoclusters (Ni NCs) for water oxidation at low overpotential. These atomically precise and monodisperse Ni NCs are characterized by using UV-visible absorption spectroscopy, single crystal X-ray diffraction and mass spectrometry. The molecular formulae of these Ni NCs are found to be Ni4(PET)8 and Ni6(PET)12 and are highly active electrocatalysts for oxygen evolution without any pre-conditioning. Ni4(PET)8 are slightly better catalysts than Ni6(PET)12 which initiate oxygen evolution at an amazingly low overpotential of ~1.51 V (vs. RHE; η ~ 280 mV). The peak oxygen evolution current density (J) of ~150 mA cm-2 at 2.0 V (vs. RHE) with a Tafel slope of 38 mV dec-1 is observed using Ni4(PET)8. These results are comparable to the state-of-the-art RuO2 electrocatalyst, which is highly expensive and rare compared to Ni-based materials. Sustained oxygen generation for several hours with an applied current density of 20 mA cm-2 demonstrates the long-term stability and activity of these Ni NCs towards electrocatalytic water oxidation. This unique approach provides a facile method to prepare cost-effective, nanoscale and highly efficient electrocatalysts for water oxidation.Achieving water splitting at low overpotential with high oxygen evolution efficiency and stability is important for realizing solar to chemical energy conversion devices. Herein we report the synthesis, characterization and electrochemical evaluation of highly active nickel nanoclusters (Ni NCs) for water oxidation at low overpotential. These atomically precise and monodisperse Ni NCs are characterized by using UV-visible absorption spectroscopy, single crystal X-ray diffraction and mass spectrometry. The molecular formulae of these Ni NCs are found to be Ni4(PET)8 and Ni6(PET)12 and are highly active electrocatalysts for oxygen evolution without any pre-conditioning. Ni4(PET)8 are slightly better catalysts than Ni6(PET)12 which initiate oxygen evolution at an amazingly low overpotential of ~1.51 V (vs. RHE; η ~ 280 mV). The peak oxygen evolution current density (J) of ~150 mA cm-2 at 2.0 V (vs. RHE) with a Tafel slope of 38 mV dec-1 is observed using Ni4(PET)8. These results are comparable to the state-of-the-art RuO2 electrocatalyst, which is highly expensive and rare compared to Ni-based materials. Sustained oxygen generation for several hours with an applied current density of 20 mA cm-2 demonstrates the long-term stability and activity of these Ni NCs towards electrocatalytic water oxidation. This unique approach provides a facile method to prepare cost-effective, nanoscale and highly efficient electrocatalysts for water oxidation. Electronic supplementary information (ESI) available: CCDC 1419754 and 1419731. For ESI and crystallographic data in CIF or other electronic format see DOI: 10.1039/c6nr00709k
Richardson-Sanchez, Tomas; Tieu, William; Gotsbacher, Michael P; Telfer, Thomas J; Codd, Rachel
2017-07-21
The water solubility of a natural product-inspired octadentate hydroxamic acid chelator designed to coordinate Zr(iv)-89 has been improved by using a combined microbiological-chemical approach to engineer four ether oxygen atoms into the main-chain region of a methylene-containing analogue. First, an analogue of the trimeric hydroxamic acid desferrioxamine B (DFOB) that contained three main-chain ether oxygen atoms (DFOB-O 3 ) was generated from cultures of the native DFOB-producer Streptomyces pilosus supplemented with oxybis(ethanamine) (OBEA), which competed against the native 1,5-diaminopentane (DP) substrate during DFOB assembly. This precursor-directed biosynthesis (PDB) approach generated a suite of DFOB analogues containing one (DFOB-O 1 ), two (DFOB-O 2 ) or three (DFOB-O 3 ) ether oxygen atoms, with the latter produced as the major species. Log P measurements showed DFOB-O 3 was about 45 times more water soluble than DFOB. Second, a peptide coupling chain-extension reaction between DFOB-O 3 and the synthetic ether-containing endo-hydroxamic acid monomer 4-((2-(2-aminoethoxy)ethyl)(hydroxy)amino)-4-oxobutanoic acid (PBH-O 1 ) gave the water soluble tetrameric hydroxamic acid DFOB-O 3 -PBH-O 1 as an isostere of sparingly water soluble DFOB-PBH. The complex between DFOB-O 3 -PBH-O 1 and nat Zr(iv), examined as a surrogate measure of the radiolabelling procedure, analysed by LC-MS as the protonated adduct ([M + H] + , m/z obs = 855.2; m/z calc = 855.3), with supporting HRMS data. The use of a microbiological system to generate a water-soluble analogue of a natural product for downstream semi-synthetic chemistry is an attractive pathway for developing new drugs and imaging agents. The improved water solubility of DFOB-O 3 -PBH-O 1 could facilitate the synthesis and purification of downstream products, as part of the ongoing development of ligands optimised for Zr(iv)-89 immunological PET imaging.
NASA Astrophysics Data System (ADS)
Terzer, Stefan; Wassenaar, Leonard I.; Douence, Cedric; Araguas-Araguas, Luis
2016-04-01
The IAEA-WMO Global Network of Isotopes in Precipitation (GNIP) provides worldwide δ18O and δ2H data for numerous hydrological and climatological studies. The traditional GNIP sample collection method relies on weather station operators to accumulate precipitation obtained from manual rain gauges. Over the past decades, widespread weather station automatization resulted in the increased use of unattended precipitation totalizers that accumulate and store the rainwater in the field for up to one month. Several low-tech measures were adopted to prevent in situ secondary evaporative isotopic enrichment (SEE) of totalized water samples (i.e. disequilibrium isotopic fractionation after precipitation is stored in the collection device). These include: (a) adding a 0.5-1 cm floating layer of paraffin oil to the totalizer bottle, (b) using an intake tube leading from the collection funnel and submerged to the bottom of the totalizer bottle, or (c) placing a table tennis ball in the funnel aiming to reduce evaporation of the collected water from the receiving bottle to the atmosphere. We assessed the isotopic integrity of stored rainwater samples for three totalizers under controlled settings: each aforementioned totalizer was filled with a 100 or 500 mL of isotopically known water and installed in the field with the intake funnels sheltered to prevent rainwater collection. Potential evapotranspiration (PET) was obtained from on-site meteorological recordings. Stored evaporative loss from each totalizer was evaluated on a monthly basis; gravimetrically and by analysing δ18O and δ2H of the stored water, for a period of 6 months and a cumulative PET of ˜500 mm. The gravimetric and isotope results revealed that for smaller water volumes (100 ml, corresponding to ca. 5 mm of monthly precipitation), negligible isotope enrichment (δ18O) was observed in the paraffin-oil based totalizer, whereas unacceptable evaporative isotope effects were observed for the ball-in-funnel collector. For the submerged-tube sampler, the evaporative effect depended on the amount of stored water: 100 ml showed unacceptable isotopic enrichment, whereas the SEE of 500 ml stored water was acceptable. These data allowed us to estimate the impact of secondary evaporative enrichment on a device-specific basis as a function of PET. Based on global PET grids (e.g. CGIAR data), and benchmarking the expected SEE against the reasonable uncertainty of isotope spectrometry (< ±0.1‰ for δ18O), these findings reveal the most suitable totalizer device for any given climatic condition. Under extreme conditions (e.g. high aridity, little precipitation vs. high PET), a paraffin-oil based rain totalizer is most appropriate for monthly collections. Submerged-tube samplers may be considered if either a higher frequency of collection were possible, or monthly under pluvial/temperate climate conditions. The use of ball-in-funnel type totalizers are not recommended at all, unless samples could be collected on a daily basis.
Magota, Keiichi; Shiga, Tohru; Asano, Yukari; Shinyama, Daiki; Ye, Jinghan; Perkins, Amy E; Maniawski, Piotr J; Toyonaga, Takuya; Kobayashi, Kentaro; Hirata, Kenji; Katoh, Chietsugu; Hattori, Naoya; Tamaki, Nagara
2017-12-01
In 3-dimensional PET/CT imaging of the brain with 15 O-gas inhalation, high radioactivity in the face mask creates cold artifacts and affects the quantitative accuracy when scatter is corrected by conventional methods (e.g., single-scatter simulation [SSS] with tail-fitting scaling [TFS-SSS]). Here we examined the validity of a newly developed scatter-correction method that combines SSS with a scaling factor calculated by Monte Carlo simulation (MCS-SSS). Methods: We performed phantom experiments and patient studies. In the phantom experiments, a plastic bottle simulating a face mask was attached to a cylindric phantom simulating the brain. The cylindric phantom was filled with 18 F-FDG solution (3.8-7.0 kBq/mL). The bottle was filled with nonradioactive air or various levels of 18 F-FDG (0-170 kBq/mL). Images were corrected either by TFS-SSS or MCS-SSS using the CT data of the bottle filled with nonradioactive air. We compared the image activity concentration in the cylindric phantom with the true activity concentration. We also performed 15 O-gas brain PET based on the steady-state method on patients with cerebrovascular disease to obtain quantitative images of cerebral blood flow and oxygen metabolism. Results: In the phantom experiments, a cold artifact was observed immediately next to the bottle on TFS-SSS images, where the image activity concentrations in the cylindric phantom were underestimated by 18%, 36%, and 70% at the bottle radioactivity levels of 2.4, 5.1, and 9.7 kBq/mL, respectively. At higher bottle radioactivity, the image activity concentrations in the cylindric phantom were greater than 98% underestimated. For the MCS-SSS, in contrast, the error was within 5% at each bottle radioactivity level, although the image generated slight high-activity artifacts around the bottle when the bottle contained significantly high radioactivity. In the patient imaging with 15 O 2 and C 15 O 2 inhalation, cold artifacts were observed on TFS-SSS images, whereas no artifacts were observed on any of the MCS-SSS images. Conclusion: MCS-SSS accurately corrected the scatters in 15 O-gas brain PET when the 3-dimensional acquisition mode was used, preventing the generation of cold artifacts, which were observed immediately next to a face mask on TFS-SSS images. The MCS-SSS method will contribute to accurate quantitative assessments. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT.
Komar, Gaber; Oikonen, Vesa; Sipilä, Hannu; Seppänen, Marko; Minn, Heikki
2012-11-01
The aim of this study was to develop a simple noninvasive method for measuring blood flow using [15O]H2O PET/CT for the head and neck area applicable in daily clinical practice. Fifteen dynamic [15O]H2O PET emission scans with simultaneous online radioactivity measurements of radial arterial blood [Blood-input functions (IFs)] were performed. Two noninvasively obtained population-based input functions were calculated by averaging all Blood-IF curves corrected for patients' body mass and injected dose [standardized uptake value (SUV)-IF] and for body surface area (BSA-IF) and injected dose. Parametric perfusion images were calculated for each set of IFs using a linearized two-compartment model, and values for several tissues were compared using Blood-IF as the gold standard. On comparing all tissues, the correlation between blood flow obtained with the invasive Blood-IF and both SUV-IF and BSA-IF was significant (R2=0.785 with P<0.001 and R2=0.813 with P<0.001, respectively). In individual tissues, the performance of the two noninvasive methods was most reliable in resting muscle and slightly less reliable in tumour and cerebellar regions. In these two tissues, only BSA-IF showed a significant correlation with Blood-IF (R2=0.307 with P=0.032 in tumours and R2=0.398 with P<0.007 in the cerebellum). The BSA-based noninvasive method enables clinically relevant delineation between areas of low and high blood flow in tumours. The blood flow of low-perfusion tissues can be reliably quantified using either of the evaluated noninvasive methods.
Frequency of use controls chemical leaching from drinking-water containers subject to disinfection.
Andra, Syam S; Makris, Konstantinos C; Shine, James P
2011-12-15
Microbial-, and chemical-based burden of disease associated with lack of access to safe water continues to primarily impact developing countries. Cost-effective health risk-mitigating measures, such as of solar disinfection applied to microbial-contaminated water stored in plastic bottles have been increasingly tested in developing countries adversely impacted by epidemic water-borne diseases. Public health concerns associated with chemical leaching from water packaging materials led us to investigate the magnitude and variability of antimony (Sb) and bromine (Br) leaching from reused plastic containers (polyethylene terephthalate, PET; and polycarbonate, PC) subject to UV and/or temperature-driven disinfection. The overall objective of this study was to determine the main and interactive effects of temperature, UV exposure duration, and frequency of bottle reuse on the extent of leaching of Sb and Br from plastic bottles into water. Regardless of UV exposure duration, frequency of reuse (up to 27 times) was the major factor that linearly increased Sb leaching from PET bottles at all temperatures tested (13-47 °C). Leached Sb concentrations (∼360 ng L(-1)) from the highly reused (27 times) PET bottles (minimal Sb leaching from PC bottles, <15 ng L(-1)) did not pose a serious risk to human health according to current daily Sb acceptable intake estimates. Leached Br concentrations from both PET and PC containers (up to ∼15 μg L(-1)) did not pose a consumer health risk either, however, no acceptable daily dose estimates exist for oral ingestion of organo-brominated, or other plasticizers/additives compounds if they were to be found in bottled water at much lower concentrations. Additional research on potential leaching of organic chemicals from water packaging materials is deemed necessary under relevant environmental conditions. Copyright © 2011 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Ali, S. Omar; Thomassen, Michael; Schulz, Geralyn M.; Hosey, Lara A.; Varga, Mary; Ludlow, Christy L.; Braun, Allen R.
2006-01-01
Speech-related changes in regional cerebral blood flow (rCBF) were measured using H[subscript 2][superscript 15]O positron-emission tomography in 9 adults with adductor spasmodic dysphonia (ADSD) before and after botulinum toxin (BTX) injection and 10 age- and gender-matched volunteers without neurological disorders. Scans were acquired at rest…
Bocher, M; Chisin, R; Parag, Y; Freedman, N; Meir Weil, Y; Lester, H; Mishani, E; Bonne, O
2001-07-01
This study attempted to use PET and 15O-H2O to measure changes in regional cerebral blood flow (rCBF) during sexual arousal evoked in 10 young heterosexual males while they watched a pornographic video clip, featuring heterosexual intercourse. This condition was compared with other mental setups evoked by noisy, nature, and talkshow audiovisual clips. Immediately after each clip, the participants answered three questions pertaining to what extent they thought about sex, felt aroused, and sensed an erection. They scored their answers using a 1 to 10 scale. SPM was used for data analysis. Sexual arousal was mainly associated with activation of bilateral, predominantly right, inferoposterior extrastriate cortices, of the right inferolateral prefrontal cortex and of the midbrain. The significance of those findings is discussed in the light of current theories concerning selective attention, "mind reading" and mirroring, reinforcement of pleasurable stimuli, and penile erection.
NASA Astrophysics Data System (ADS)
Muinul Islam, Muhammad; Tsujikawa, Tetsuya; Mori, Tetsuya; Kiyono, Yasushi; Okazawa, Hidehiko
2017-06-01
A noninvasive method to estimate input function directly from H2 15O brain PET data for measurement of cerebral blood flow (CBF) was proposed in this study. The image derived input function (IDIF) method extracted the time-activity curves (TAC) of the major cerebral arteries at the skull base from the dynamic PET data. The extracted primordial IDIF showed almost the same radioactivity as the arterial input function (AIF) from sampled blood at the plateau part in the later phase, but significantly lower radioactivity in the initial arterial phase compared with that of AIF-TAC. To correct the initial part of the IDIF, a dispersion function was applied and two constants for the correction were determined by fitting with the individual AIF in 15 patients with unilateral arterial stenoocclusive lesions. The area under the curves (AUC) from the two input functions showed good agreement with the mean AUCIDIF/AUCAIF ratio of 0.92 ± 0.09. The final products of CBF and arterial-to-capillary vascular volume (V 0) obtained from the IDIF and AIF showed no difference, and had with high correlation coefficients.
Role of CO2 in the cerebral hyperemic response to incremental normoxic and hyperoxic exercise
Wildfong, K. W.; Hoiland, R. L.; Harper, M.; Lewis, N. C.; Pool, A.; Smith, S. L.; Kuca, T.; Ainslie, P. N.
2016-01-01
Cerebral blood flow (CBF) is temporally related to exercise-induced changes in partial pressure of end-tidal carbon dioxide (PetCO2); hyperoxia is known to enhance this relationship. We examined the hypothesis that preventing PetCO2 from rising (isocapnia) during submaximal exercise with and without hyperoxia [end-tidal Po2 (PetO2) = 300 mmHg] would attenuate the increases in CBF. Additionally, we aimed to identify the magnitude that breathing, per se, influences the CBF response to normoxic and hyperoxic exercise. In 14 participants, CBF (intra- and extracranial) measurements were measured during exercise [20, 40, 60, and 80% of maximum workload (Wmax)] and during rest while ventilation (V̇e) was volitionally increased to mimic volumes achieved during exercise (isocapnic hyperpnea). While V̇e was uncontrolled during poikilocapnic exercise, during isocapnic exercise and isocapnic hyperpnea, V̇e was increased to prevent PetCO2 from rising above resting values (∼40 mmHg). Although PetCO2 differed by 2 ± 3 mmHg during normoxic poikilocapnic and isocapnic exercise, except for a greater poikilocapnic compared with isocapnic increase in blood velocity in the posterior cerebral artery at 60% Wmax, the between condition increases in intracranial (∼12-15%) and extracranial (15–20%) blood flow were similar at each workload. The poikilocapnic hyperoxic increases in both intra- and extracranial blood-flow (∼17–29%) were greater compared with poikilocapnic normoxia (∼8–20%) at intensities >40% Wmax (P < 0.01). During both normoxic and hyperoxic conditions, isocapnia normalized both the intracranial and extracranial blood-flow differences. Isocapnic hyperpnea did not alter CBF. Our findings demonstrate a differential effect of PetCO2 on CBF during exercise influenced by the prevailing PetO2. PMID:26769951
Obliquity (41kyr) Paced SE Asian Monsoon Variability Following the Miocene Climate Transition
NASA Astrophysics Data System (ADS)
Heitmann, E. O.; Breecker, D.; Ji, S.; Nie, J.
2016-12-01
We investigated Asian monsoon variability during the Miocene, which may provide a good analog for the future given the lack of northern hemisphere ice sheets. In the Miocene Yanwan Section (Tianshui Basin, China) 25cm thick CaCO3-cemented horizons overprint siltstones every 1m. We suggest this rhythmic layering records variations in water availability influenced by the Asian monsoon. We interpret the siltstones as stacked soils that formed in a seasonal climate with a fluctuating water table, evidenced by roots, clay films, mottling, presence of CaCO3 nodules, and stacked carbonate nodule δ13C and δ18O profiles that mimic modern soils. We interpret the CaCO3-cemented horizons as capillary-fringe carbonates that formed in an arid climate with a steady water table and high potential evapotranspiration (PET), evidenced by sharp upper and basal contacts, micrite, sparite, and root-pore cements. The magnetostratigraphy-based age model indicates obliquity-pacing of the CaCO3-cemented horizons suggesting an orbital control on water availability, for which we propose two mechanisms: 1) summer monsoon strength, moderated by the control of obliquity on the cross-equatorial pressure gradient, and 2) PET, moderated by the control of precession on 35oN summer insolation. We use orbital configurations to predict lithology. Coincidence of obliquity minima and insolation maxima drives strong summer monsoons, seasonal variations in water table depth and soil formation. Coincidence of obliquity maxima and insolation minima drives weak summer monsoons, high PET, and carbonate accumulation above a deepened, stable water table. Coincidence of obliquity and insolation minima drives strong monsoons, low PET, and a high water table, explaining the evidence for aquatic plants previously observed in this section. Southern hemisphere control of summer monsoon variability in the Miocene may thus have resulted in large water availability variations in central China.
Chapa-Martínez, C A; Hinojosa-Reyes, L; Hernández-Ramírez, A; Ruiz-Ruiz, E; Maya-Treviño, L; Guzmán-Mar, J L
2016-09-15
The leaching of antimony (Sb) from polyethylene terephthalate (PET) bottling material was assessed in twelve brands of bottled water purchased in Mexican supermarkets by atomic fluorescence spectrometry with a hydride generation system (HG-AFS). Dowex® 1X8-100 ion-exchange resin was used to preconcentrate trace amounts of Sb in water samples. Migration experiments from the PET bottle material were performed in water according to the following storage conditions: 1) temperature (25 and 75°C), 2) pH (3 and 7) and 3) exposure time (5 and 15days), using ultrapure water as a simulant for liquid foods. The test conditions were studied by a 2(3) factorial experimental design. The Sb concentration measured in the PET packaging materials varied between 73.0 and 111.3mg/kg. The Sb concentration (0.28-2.30μg/L) in all of the PET bottled drinking water samples examined at the initial stage of the study was below the maximum contaminant level of 5μg/L prescribed by European Union (EU) regulations. The parameters studied (pH, temperature, and storage time) significantly affected the release of Sb, with temperature having the highest positive significant effect within the studied experimental domain. The highest Sb concentration leached from PET containers was in water samples at pH7 stored at 75°C for a period of 5days. The extent of Sb leaching from the PET ingredients for different brands of drinking water can differ by as much as one order of magnitude in experiments conducted under the worst-case conditions. The chronic daily intake (CDI) caused by the release of Sb in one brand exceeded the Environmental Protection Agency (USEPA) regulated CDI value of 400ng/kg/day, with values of 514.3 and 566.2ng/kg/day for adults and children. Thus, the appropriate selection of the polymer used for the production of PET bottles seems to ensure low Sb levels in water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rosso, V.; Battistoni, G.; Belcari, N.; Camarlinghi, N.; Ciocca, M.; Collini, F.; Ferretti, S.; Kraan, A. C.; Lucenò, S.; Molinelli, S.; Pullia, M.; Sportelli, G.; Zaccaro, E.; Del Guerra, A.
2016-07-01
One of the most promising new radiotherapy techniques makes use of charged particles like protons and carbon ions, rather than photons. At present, there are more than 50 particle therapy centers operating worldwide, and many new centers are being constructed. Positron Emission Tomography (PET) is considered a well-established non-invasive technique to monitor range and delivered dose in patients treated with particle therapy. Nuclear interactions of the charged hadrons with the patient tissue lead to the production of β+ emitting isotopes (mainly 15O and 11C), that decay with a short lifetime producing a positron. The two 511 keV annihilation photons can be detected with a PET detector. In-beam PET is particularly interesting because it could allow monitoring the ions range also during dose delivery. A large area dual head PET prototype was built and tested. The system is based on an upgraded version of the previously developed DoPET prototype. Each head covers now 15×15 cm2 and is composed by 9 (3×3) independent modules. Each module consists of a 23×23 LYSO crystal matrix (2 mm pitch) coupled to H8500 PMT and is readout by custom front-end and a FPGA based data acquisition electronics. Data taken at the CNAO treatment facility in Pavia with proton and carbon beams impinging on heterogeneous phantoms demonstrate the DoPET capability to detect the presence of a small air cavity in the phantom.
Measurement of regional cerebral blood flow with copper-62-PTSM and a three-compartment model.
Okazawa, H; Yonekura, Y; Fujibayashi, Y; Mukai, T; Nishizawa, S; Magata, Y; Ishizu, K; Tamaki, N; Konishi, J
1996-07-01
We evaluated quantitatively 62Cu-labeled pyruvaldehyde bis(N4-methylthiosemicarbazone) copper II (62Cu-PTSM) as a brain perfusion tracer for positron emission tomography (PET). For quantitative measurement, the octanol extraction method is needed to correct for arterial radioactivity in estimating the lipophilic input function, but the procedure is not practical for clinical studies. To measure regional cerebral blood flow (rCBF) by 62Cu-PTSM with simple arterial blood sampling, a standard curve of the octanol extraction ratio and a three-compartment model were applied. We performed both 15O-labeled water PET and 62 Cu-PTSM PET with dynamic data acquisition and arterial sampling in six subjects. Data obtained in 10 subjects studied previously were used for the standard octanol extraction curve. Arterial activity was measured and corrected to obtain the true input function using the standard curve. Graphical analysis (Gjedde-Patlak plot) with the data for each subject fitted by a straight regression line suggested that 62Cu-PTSM can be analyzed by the three-compartment model with negligible K4. Using this model, K1-K3 were estimated from curve fitting of the cerebral time-activity curve and the corrected input function. The fractional uptake of 62Cu-PTSM was corrected to rCBF with the individual extraction at steady state calculated from K1-K3. The influx rates (Ki) obtained from three-compartment model and graphical analyses were compared for the validation of the model. A comparison of rCBF values obtained from 62Cu-PTSM and 150-water studies demonstrated excellent correlation. The results suggest the potential feasibility of quantitation of cerebral perfusion with 62Cu-PTSM accompanied by dynamic PET and simple arterial sampling.
McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Herrero, Pilar; Misselwitz, Bernd; Gropler, Robert J.; Zheng, Jie
2011-01-01
Background A comprehensive evaluation of myocardial ischemia requires measures of both oxygen supply and demand. Positron emission tomography (PET) is currently the gold standard for such evaluations, but its use is limited due to its ionizing radiation, limited availability, and high cost. A cardiac magnetic resonance imaging (MRI) method was developed for assessing myocardial oxygenation. The purpose of this study was to evaluate and validate this technique compared to PET during pharmacologic stress in a canine model of coronary artery stenosis. Methods and Results Twenty-one beagles and small mongrel dogs without coronary artery stenosis (controls), or with moderate to severe acute coronary artery stenosis underwent MRI and PET imaging at rest and during dipyridamole vasodilation or dobutamine stress to induce a wide range of changes in cardiac perfusion and oxygenation. MRI first-pass perfusion imaging was performed to quantify myocardial blood flow (MBF) and volume (MBV). The MRI blood-oxygen-level-dependent (BOLD) technique was used to determine the myocardial oxygen extraction fraction (OEF) during pharmacologic hyperemia. Myocardial oxygen consumption (MVO2) was determined by Fick’s law. In the same dogs, 15O-water and 11C-acetate were used to measure MBF and MVO2, respectively, by PET. Regional assessments were performed for both MR and PET. MRI data correlated nicely with PET values for MBF (R2 = 0.79, P < 0.001), MVO2 (R2 = 0.74, P < 0.001), and OEF (R2 = 0.66, P < 0.01). Conclusions Cardiac MRI methods may provide an alternative to radionuclide imaging in settings of myocardial ischemia. Our newly developed quantitative MRI oxygenation imaging technique may be a valuable non-invasive tool to directly evaluate myocardial energetics and efficiency. PMID:19933371
Cui, Xianjin; Belo, Salome; Krüger, Dirk; Yan, Yong; de Rosales, Rafael T.M.; Jauregui-Osoro, Maite; Ye, Haitao; Su, Shi; Mathe, Domokos; Kovács, Noémi; Horváth, Ildikó; Semjeni, Mariann; Sunassee, Kavitha; Szigeti, Krisztian; Green, Mark A.; Blower, Philip J.
2014-01-01
Magnetic nanoparticles (NPs) MnFe2O4 and Fe3O4 were stabilised by depositing an Al(OH)3 layer via a hydrolysis process. The particles displayed excellent colloidal stability in water and a high affinity to [18F]-fluoride and bisphosphonate groups. A high radiolabeling efficiency, 97% for 18F-fluoride and 100% for 64Cu-bisphosphonate conjugate, was achieved by simply incubating NPs with radioactivity solution at room temperature for 5 min. The properties of particles were strongly dependant on the thickness and hardness of the Al(OH)3 layer which could in turn be controlled by the hydrolysis method. The application of these Al(OH)3 coated magnetic NPs in molecular imaging has been further explored. The results demonstrated that these NPs are potential candidates as dual modal probes for MR and PET. In vivo PET imaging showed a slow release of 18F from NPs, but no sign of efflux of 64Cu. PMID:24768194
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Positron emission tomography in oncology: the most sophisticated imaging technology.
Lacić, M; Maisey, M N; Kusić, Z
1997-01-01
The primary aim of this paper is to present a new nuclear medicine technology, which has just recently crossed over the clinical-research barrier. Positron emission tomography (PET) has become one of the routine functional imaging techniques in the most developed countries. The biggest advantage of PET is the usage of short-lived positron emission radionuclides, e.g., fluorine-18 (F-18), carbon-11 (C-11), nitrogen-13, and oxygen-15 (0-15). These radionuclides could be incorporated (H2O15) or linked (F-18 fluorodeoxyglucose (FDG) to different metabolically active molecules. In this way, it is possible to image and quantify the metabolic activity of various disorders and diseases including different types of tumors. The authors have concentrated on the PET rule in oncology. FDG and C-11 methionine are the most widely used PET radiopharmaceuticals in tumor imaging today, thus the results of human PET studies with FDG and C-11 methionine in the evaluation of tumors have been reviewed. The facts about the mechanism of uptake of both metabolic PET radiopharmaceuticals as well as the kinetics of tracers in normal and tumor tissue are described. The problem of accumulation of these tracers in some benign lesions is also mentioned. PET could be used for the evaluation of tumor response to therapy and duration of therapeutic effects in follow-up studies. PET offers a unique possibility to fully quantify the tumor metabolic activity, although semi-quantitative approaches are clinically more convenient. At the end, comparative studies of FDG and C-11 methionine in tumor evaluation are analyzed. A double-tracer FDG and C-11 methionine scanning protocol has been suggested as very useful for the assessment of brain tumor. This finding was also supported by the authors' data.
Monitoring proton radiation therapy with in-room PET imaging
NASA Astrophysics Data System (ADS)
Zhu, Xuping; España, Samuel; Daartz, Juliane; Liebsch, Norbert; Ouyang, Jinsong; Paganetti, Harald; Bortfeld, Thomas R.; El Fakhri, Georges
2011-07-01
We used a mobile positron emission tomography (PET) scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate in-room short, in-room long and off-line equivalent (by skipping coincidences from the first 15 min during the list-mode reconstruction) PET images for comparison in activity distribution patterns. A phantom study was followed to evaluate the accuracy of range verification for different reconstruction time schemes quantitatively. The in-room PET has a higher sensitivity compared to the off-line modality so that the PET acquisition time can be greatly reduced from 30 to <5 min. Features in deep-site, soft-tissue regions were better retained with in-room short PET acquisitions because of the collection of 15O component and lower biological washout. For soft tissue-equivalent material, the distal fall-off edge of an in-room short acquisition is deeper compared to an off-line equivalent scan, indicating a better coverage of the high-dose end of the beam. In-room PET is a promising low cost, high sensitivity modality for the in vivo verification of proton therapy. Better accuracy in Monte Carlo predictions, especially for biological decay modeling, is necessary.
A simulation study of a dual-plate in-room PET system for dose verification in carbon ion therapy
NASA Astrophysics Data System (ADS)
Chen, Ze; Hu, Zheng-Guo; Chen, Jin-Da; Zhang, Xiu-Ling; Guo, Zhong-Yan; Xiao, Guo-Qing; Sun, Zhi-Yu; Huang, Wen-Xue; Wang, Jian-Song
2014-08-01
During carbon ion therapy, lots of positron emitters such as 11C, 15O, 10C are generated in irradiated tissues by nuclear reactions, and can be used to track the carbon beam in the tissue by a positron emission tomography (PET) scanner. In this study, an dual-plate in-room PET scanner has been designed and evaluated based on the GATE simulation platform to monitor patient dose in carbon ion therapy. The dual-plate PET is designed to avoid interference with the carbon beamline and with patient positioning. Its performance was compared with that of four-head and full-ring PET scanners. The dual-plate, four-head and full-ring PET scanners consisted of 30, 60, 60 detector modules, respectively, with a 36 cm distance between directly opposite detector modules for dose deposition measurements. Each detector module consisted of a 24×24 array of 2 mm×2 mm×18 mm LYSO pixels coupled to a Hamamatsu H8500 PMT. To estimate the production yield of positron emitters, a 10 cm×15 cm×15 cm cuboid PMMA phantom was irradiated with 172, 200, 250 MeV/u 12C beams. 3D images of the activity distribution measured by the three types of scanner are produced by an iterative reconstruction algorithm. By comparing the longitudinal profile of positron emitters along the carbon beam path, it is indicated that use of the dual-plate PET scanner is feasible for monitoring the dose distribution in carbon ion therapy.
Water storage at the Panola Mountain Research Watershed, Georgia, USA
Peters, N.E.; Aulenbach, Brent T.
2011-01-01
Storage is a major component of a catchment water balance particularly when the water balance components are evaluated on short time scales, that is, less than annual. We propose a method of determining the storage-discharge relation using an exponential function and daily precipitation, potential evapotranspiration (PET) and baseflow during the dormant season when evapotranspiration (ET) is low. The method was applied to the 22-year data series of the 0.41-ha forested Panola Mountain Research Watershed, Georgia. The relation of cumulative daily precipitation minus daily runoff and PET versus baseflow was highly significant (r2=0.92, p<0.0001), but the initial storage for each year varied markedly. For the 22-year study period, annual precipitation and runoff averaged 1240 and 380mm, respectively, whereas the absolute catchment storage range was ~400mm, averaging 219mm annually, which is attributed to contributions of soil water and groundwater. The soil moisture of a catchment average 1-m soil depth was evaluated and suggests that there was an active (changes in soil storage during stormflow) and passive (a longer-term seasonal cycle) soil water storage with ranges of 40-70 and 100-120mm, respectively. The active soil water storage was short term on the order of days during and immediately after rainstorms, and the passive or seasonal soil storage was highest during winter when ET was lowest and lowest during summer when ET was highest. An estimate of ET from daily changes in soil moisture (ETSM) during recessions was comparable with PET during the dormant season (1.5mmday-1) but was much lower during the growing season (June through August); monthly average SMET and PET ranged from 2.8 to 4.0mmday-1 and from 4.5 to 5.5mmday-1, respectively. The growing season difference is attributed to the overestimation of PET. ETSM estimates were comparable with those derived from hillslope water balances during sprinkling experiments. Master recession curves derived from the storage-discharge relation adjusted seasonally for ET (1.5 and 4.0mmday-1 during the dormant and growing seasons, respectively) fit actual recessions extremely well. ?? 2011 John Wiley & Sons, Ltd.
Hamdy, Samar; Haddadi, Azita; Somayaji, Vishwa; Ruan, David; Samuel, John
2007-08-15
The present study had two main objectives. First, was to compare the immune stimulatory effect of two synthetic lipid A analogues (7-acyl lipid A and pentaerythritol-based lipid A (PET lipid A)) on maturation/stimulation of bone marrow derived dendritic cells (DCs). Our second objective was to develop a liquid chromatography/mass spectrometry (LC-MS) method for the quantitative analysis of lipid A-based vaccine adjuvants. Treatment of immature DCs with 7-acyl lipid A and PET lipid A up regulated the surface expression of CD86 and CD40 molecules, and also induced similar profile of pro-inflammatory cytokine secretion. LC-MS analyses were performed using a Waters Micromass ZQ 4000 spectrometer, coupled to a Waters 2795 separations module with an autosampler. Calibration curves with R(2)>0.999 were constructed over the concentration range of 1.25-20 microg/ml for the solution of 7-acyl lipid A and PET lipid A. The method was tested in a 3 day validation protocol. The accuracy of the assay at different concentrations tested ranged from 89 to 108% and from 92 to 107% for 7-acyl lipid A and PET lipid A, respectively. The limit of quantification for both 7-acyl lipid A and PET lipid A was 1.25 microg/ml (signal/noise (S/N)) ratio >15:1. The sensitivity of the method (the limit of detection) was 0.35 and 0.15 ng for 7-acyl lipid A and PET lipid A, respectively (S/N ratio between 4:1 or 3:1). As a preliminary application, this method has been successfully applied to the determination of 7-acyl lipid A and PET lipid A content in poly (D,L-lactic-co-glycolic acid) nanoparticles (PLGA-NP).
Quantification of 18F-Fluoride Kinetics: Evaluation of Simplified Methods.
Raijmakers, Pieter; Temmerman, Olivier P P; Saridin, Carrol P; Heyligers, Ide C; Becking, Alfred G; van Lingen, Arthur; Lammertsma, Adriaan A
2014-07-01
(18)F-fluoride PET is a promising noninvasive method for measuring bone metabolism and bone blood flow. The purpose of this study was to assess the performance of various clinically useful simplified methods by comparing them with full kinetic analysis. In addition, the validity of deriving bone blood flow from K1 of (18)F-fluoride was investigated using (15)O-H2O as a reference. Twenty-two adults (mean age ± SD, 44.8 ± 25.2 y), including 16 patients scheduled for bone surgery and 6 healthy volunteers, were studied. All patients underwent dynamic (15)O-H2O and (18)F-fluoride scans before surgery. Ten of these patients had serial PET measurements before and at 2 time points after local bone surgery. During all PET scans, arterial blood was monitored continuously. (18)F-fluoride data were analyzed using nonlinear regression (NLR) and several simplified methods (Patlak and standardized uptake value [SUV]). SUV was evaluated for different time intervals after injection and after normalizing to body weight, lean body mass, and body surface area, and simplified measurements were compared with NLR results. In addition, changes in SUV and Patlak-derived fluoride influx rate (Ki) after surgery were compared with corresponding changes in NLR-derived Ki. Finally, (18)F-fluoride K1 was compared with bone blood flow derived from (15)O-H2O data, using the standard single-tissue-compartment model. K1 of (18)F-fluoride correlated with measured blood flow, but the correlation coefficient was relatively low (r = 0.35, P < 0.001). NLR resulted in a mean Ki of 0.0160 ± 0.0122, whereas Patlak analysis, for the interval 10-60 min after injection, resulted in an almost-identical mean Ki of 0.0161 ± 0.0117. The Patlak-derived Ki, for 10-60 min after injection, showed a high correlation with the NLR-derived Ki (r = 0.976). The highest correlation between Ki and lean body mass-normalized SUV was found for the interval 50-60 min (r = 0.958). Finally, changes in SUV correlated significantly with those in Ki (r = 0.97). The present data support the use of both Patlak and SUV for assessing fluoride kinetics in humans. However, (18)F-fluoride PET has only limited accuracy in monitoring bone blood flow. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Hydrophilic-impermeable modified polyethylene terephthalate for selective endothelialization
NASA Astrophysics Data System (ADS)
Chetouane, D.; Fafet, J. F.; Barbet, R.; Dieval, F.
2017-10-01
The aim of this study was to create a modified polyethylene terephthalate (PET) responding to vascular implants’ requirements, mainly with a surface promoting selective endothelialization. The surface alteration was carried out by hydrophilic functionalization in an alkaline solution with the presence of specific surfactant (TA). The carboxylic groups resulting from this reaction were quantified by colorimetric titration using bleu toluidine O dye (TBO). A single-sided coating process was then optimized to cover the PET surface by micro spherical structures’ polymeric layer. This coating provided to the PET surface high impermeability to the water under a pressure of 120 mmHg and enhanced its hydrophilic property. This spherical topography reduced the adhesion of Mesenchymal Stem Cells (MSC) by 37% and inhibited their proliferation after 3 days by 50%. The hydrophilic functionalized PET (PET-TA) surface decreased the MSC adhesion by 50% and promoted HUVEC attachment with a number twice more important than the number of HUVEC adhered onto non treated-PET.
Monkul, E Serap; Silva, Leandro A P; Narayana, Shalini; Peluso, Marco A M; Zamarripa, Frank; Nery, Fabiano G; Najt, Pablo; Li, John; Lancaster, Jack L; Fox, Peter T; Lafer, Beny; Soares, Jair C
2012-02-01
We investigated the differences in the resting state corticolimbic blood flow between 20 unmedicated depressed patients and 21 healthy comparisons. Resting state cerebral blood flow (CBF) was measured with H(2)(15)O PET. Anatomical MRI scans were performed on an Elscint 1.9 T Prestige system for PET-MRI coregistration. Significant changes in cerebral blood flow indicating neural activity were detected using an ROI-free image subtraction strategy. In addition, the resting blood flow in patients was correlated with the severity of depression as measured by HAM-D scores. Depressed patients showed decreases in blood flow in right anterior cingulate (Brodmann areas 24 and 32) and increased blood flow in left and right posterior cingulate (Brodmann areas 23, 29, 30), left parahippocampal gyrus (Brodmann area 36), and right caudate compared with healthy volunteers. The severity of depression was inversely correlated with the left middle and inferior frontal gyri (Brodmann areas 9 and 47) and right medial frontal gyrus (Brodmann area 10) and right anterior cingulate (Brodmann areas 24, 32) blood flow, and directly correlated with the right thalamus blood flow. These findings support previous reports of abnormalities in the resting state blood flow in the limbic-frontal structures in depressed patients compared to healthy volunteers. Copyright © 2011 Wiley Periodicals, Inc.
Sarikaya, Ismet
2015-01-01
Various PET studies, such as measurements of glucose, serotonin and oxygen metabolism, cerebral blood flow and receptor bindings are availabe for epilepsy. 18Fluoro-2-deoxyglucose (18F-FDG) PET imaging of brain glucose metabolism is a well established and widely available technique. Studies have demonstrated that the sensitivity of interictal FDG-PET is higher than interictal SPECT and similar to ictal SPECT for the lateralization and localization of epileptogenic foci in presurgical patients refractory to medical treatments who have noncontributory EEG and MRI. In addition to localizing epileptogenic focus, FDG-PET provide additional important information on the functional status of the rest of the brain. The main limitation of interictal FDG-PET is that it cannot precisely define the surgical margin as the area of hypometabolism usually extends beyond the epileptogenic zone. Various neurotransmitters (GABA, glutamate, opiates, serotonin, dopamine, acethylcholine, and adenosine) and receptor subtypes are involved in epilepsy. PET receptor imaging studies performed in limited centers help to understand the role of neurotransmitters in epileptogenesis, identify epileptic foci and investigate new treatment approaches. PET receptor imaging studies have demonstrated reduced 11C-flumazenil (GABAA-cBDZ) and 18F-MPPF (5-HT1A serotonin) and increased 11C-cerfentanil (mu opiate) and 11C-MeNTI (delta opiate) bindings in the area of seizure. 11C-flumazenil has been reported to be more sensitive than FDG-PET for identifying epileptic foci. The area of abnormality on GABAAcBDZ and opiate receptor images is usually smaller and more circumscribed than the area of hypometabolism on FDG images. Studies have demonstrated that 11C-alpha-methyl-L-tryptophan PET (to study synthesis of serotonin) can detect the epileptic focus within malformations of cortical development and helps in differentiating epileptogenic from non-epileptogenic tubers in patients with tuberous sclerosis complex. 15O-H2O PET was reported to have a similar sensitivity to FDG-PET in detecting epileptic foci. PMID:26550535
Klinge, Petra M; Brooks, David J; Samii, Amir; Weckesser, Eva; van den Hoff, Jörg; Fricke, Harald; Brinker, Thomas; Knapp, Wolfram H; Berding, Georg
2008-04-01
Findings in local cerebral blood flow (rCBF) in Normal pressure hydrocephalus (NPH) have always been challenged by the variable and inconsistent relation to clinical symptoms before and after shunt treatment. [(15)O]H(2)O PET data from a consecutive cohort of 65 idiopathic NPH patients were retrospectively analyzed questioning whether the functional status before and after shunt treatment might correlate with local blood flow. Using statistical parametric mapping (SPM99, Wellcome Department of Cognitive Neurology, London), the [(15)O]H(2)O uptake was correlated with the preoperative clinical scores, graded according to a modified Stein and Langfitt score. Furthermore, differences in the uptake in the pre-and post-shunt treatment study after seven to 10 days in patients with and without clinical improvement were studied. A higher clinical score significantly correlated with a reduced tracer uptake in mesial frontal (k=1,239 voxel, Z=4.41) and anterior temporal (k=469, Z=4.07) areas. In the mesial frontal areas, tracer uptake showed significant reciprocal changes in the clinically improved vs. the unimproved patients. Matched with the existing literature, the regional blood flow alterations are suggested relevant to the NPH syndrome and to post-treatment functional changes. The present rCBF findings warrant prospective studies on the accuracy of neuroimaging studies as they may provide a more specific insight into disease mechanisms.
Methods for the correction of vascular artifacts in PET O-15 water brain-mapping studies
NASA Astrophysics Data System (ADS)
Chen, Kewei; Reiman, E. M.; Lawson, M.; Yun, Lang-sheng; Bandy, D.; Palant, A.
1996-12-01
While positron emission tomographic (PET) measurements of regional cerebral blood flow (rCBF) can be used to map brain regions that are involved in normal and pathological human behaviors, measurements in the anteromedial temporal lobe can be confounded by the combined effects of radiotracer activity in neighboring arteries and partial-volume averaging. The authors now describe two simple methods to address this vascular artifact. One method utilizes the early frames of a dynamic PET study, while the other method utilizes a coregistered magnetic resonance image (MRI) to characterize the vascular region of interest (VROI). Both methods subsequently assign a common value to each pixel in the VROI for the control (baseline) scan and the activation scan. To study the vascular artifact and to demonstrate the ability of the proposed methods correcting the vascular artifact, four dynamic PET scans were performed in a single subject during the same behavioral state. For each of the four scans, a vascular scan containing vascular activity was computed as the summation of the images acquired 0-60 s after radiotracer administration, and a control scan containing minimal vascular activity was computed as the summation of the images acquired 20-80 s after radiotracer administration. t-score maps calculated from the four pairs of vascular and control scans were used to characterize regional blood flow differences related to vascular activity before and after the application of each vascular artifact correction method. Both methods eliminated the observed differences in vascular activity, as well as the vascular artifact observed in the anteromedial temporal lobes. Using PET data from a study of normal human emotion, these methods permitted the authors to identify rCBF increases in the anteromedial temporal lobe free from the potentially confounding, combined effects of vascular activity and partial-volume averaging.
DoPET: an in-treatment monitoring system for proton therapy at 62 MeV
NASA Astrophysics Data System (ADS)
Rosso, V.; Belcari, N.; Bisogni, M. G.; Camarlinghi, N.; Cirrone, G. A. P.; Collini, F.; Cuttone, G.; Del Guerra, A.; Milluzzo, G.; Morrocchi, M.; Raffaele, L.; Romano, F.; Sportelli, G.; Zaccaro, E.
2016-12-01
Proton beam radiotherapy is highly effective in treating cancer thanks to its conformal dose deposition. This superior capability in dose deposition has led to a massive growth of the treated patients around the world, raising the need of treatment monitoring systems. An in-treatment PET system, DoPET, was constructed and tested at CATANA beam-line, LNS-INFN in Catania, where 62 MeV protons are used to treat ocular melanoma. The PET technique profits from the beta+ emitters generated by the proton beam in the irradiated body, mainly 15-O and 11-C. The current DoPET prototype consists of two planar 15 cm × 15 cm LYSO-based detector heads. With respect to the previous versions, the system was enlarged and the DAQ up-graded during the years so now also anthropomorphic phantoms, can be fitted within the field of view of the system. To demonstrate the capability of DoPET to detect changes in the delivered treatment plan with respect to the planned one, various treatment plans were used delivering a standard 15 Gy fraction to an anthropomorphic phantom. Data were acquired during and after the treatment delivery up to 10 minutes. When the in-treatment phase was long enough (more than 1 minute), the corresponding activated volume was visible just after the treatment delivery, even if in presence of a noisy background. The after-treatment data, acquired for about 9 minutes, were segmented finding that few minutes are enough to be able to detect changes. These experiments will be presented together with the studies performed with PMMA phantoms where the DoPET response was characterized in terms of different dose rates and in presence of range shifters: the system response is linear up to 16.9 Gy/min and has the ability to see a 1 millimeter range shifter.
Ferrieri, Richard A.; Schlyer, David J.; Shea, Colleen
1995-06-13
A process for simultaneously producing PET-usable quantities of [.sup.13 N]NH.sub.3 and [.sup.18 F]F.sup.- for radiotracer synthesis is disclosed. The process includes producing [.sup.13 N]NO.sub.2.sup.- /NO.sub.3.sup.- and [.sup.18 F]F.sup.- simultaneously by exposing a low-enriched (20%-30%) [.sup.18 O]H.sub.2 O target to proton irradiation, sequentially isolating the [.sup.13 N]NO.sub.2.sup.- /NO.sub.3.sup.- and [.sup.18 F]F.sup.- from the [.sup.18 O]H.sub.2 O target, and reducing the [.sup.13 N]NO.sub.2.sup.- /NO.sub.3.sup.- to [.sup.13 N]NH.sub.3. The [.sup.13 N]NH.sub.3 and [.sup.18 F]F.sup.- products are then conveyed to a laboratory for radiotracer applications. The process employs an anion exchange resin for isolation of the isotopes from the [.sup.18 O]H.sub.2 O, and sequential elution of [.sup.13 N]NO.sub.2.sup.- /NO.sub.3.sup.- and [ .sup.18 F]F.sup.- fractions. Also the apparatus is disclosed for simultaneously producing PET-usable quantities of [.sup.13 N]NH.sub.3 and [.sup.18 F]F.sup.- from a single irradiation of a single low-enriched [.sup.18 O]H.sub.2 O target.
NASA Astrophysics Data System (ADS)
Cho, Jongmin; Ibbott, Geoffrey; Gillin, Michael; Gonzalez-Lepera, Carlos; Min, Chul Hee; Zhu, Xuping; El Fakhri, Georges; Paganetti, Harald; Mawlawi, Osama
2013-06-01
Positron emission tomography (PET) has been suggested as an imaging technique for in vivo proton dose and range verification after proton induced-tissue activation. During proton treatment, irradiated tissue is activated and decays while emitting positrons. In this paper, we assessed the feasibility of using PET imaging after proton treatment to determine tissue elemental composition by evaluating the resultant composite decay curve of activated tissue. A phantom consisting of sections composed of different combinations of 1H, 12C, 14N, and 16O was irradiated using a pristine Bragg peak and a 6 cm spread-out Bragg-peak (SOBP) proton beam. The beam ranges defined at 90% distal dose were 10 cm the delivered dose was 1.6 Gy for the near monoenergetic beam and 2 Gy for the SOBP beam. After irradiation, activated phantom decay was measured using an in-room PET scanner for 30 min in list mode. Decay curves from the activated 12C and 16O sections were first decomposed into multiple simple exponential decay curves, each curve corresponding to a constituent radioisotope, using a least-squares method. The relative radioisotope fractions from each section were determined. These fractions were used to guide the decay curve decomposition from the section consisting mainly of 12C + 16O and calculate the relative elemental composition of 12C and 16O. A Monte Carlo simulation was also used to determine the elemental composition of the 12C + 16O section. The calculated compositions of the 12C + 16O section using both approaches (PET and Monte Carlo) were compared with the true known phantom composition. Finally, two patients were imaged using an in-room PET scanner after proton therapy of the head. Their PET data and the technique described above were used to construct elemental composition (12C and 16O) maps that corresponded to the proton-activated regions. We compared the 12C and 16O compositions of seven ROIs that corresponded to the vitreous humor, adipose/face mask, adipose tissue, and brain tissue with ICRU 46 elemental composition data. The 12C and 16O compositions of the 12C + 16O phantom section were estimated to within a maximum difference of 3.6% for the near monoenergetic and SOBP beams over an 8 cm depth range. On the other hand, the Monte Carlo simulation estimated the corresponding 12C and 16O compositions in the 12C + 16O section to within a maximum difference of 3.4%. For the patients, the 12C and 16O compositions in the seven ROIs agreed with the ICRU elemental composition data, with a mean (maximum) difference of 9.4% (15.2%). The 12C and 16O compositions of the phantom and patients were estimated with relatively small differences. PET imaging may be useful for determining the tissue elemental composition and thereby improving proton treatment planning and verification.
Neuroanatomical correlates of encoding in episodic memory: levels of processing effect.
Kapur, S; Craik, F I; Tulving, E; Wilson, A A; Houle, S; Brown, G M
1994-01-01
Cognitive studies of memory processes demonstrate that memory for stimuli is a function of how they are encoded; stimuli processed semantically are better remembered than those processed in a perceptual or shallow fashion. This study investigates the neural correlates of this cognitive phenomenon. Twelve subjects performed two different cognitive tasks on a series of visually presented nouns. In one task, subjects detected the presence or absence of the letter a; in the other, subjects categorized each noun as living or nonliving. Positron emission tomography (PET) scans using 15O-labeled water were obtained during both tasks. Subjects showed substantially better recognition memory for nouns seen in the living/nonliving task, compared to nouns seen in the a-checking task. Comparison of the PET images between the two cognitive tasks revealed a significant activation in the left inferior prefrontal cortex (Brodmann's areas 45, 46, 47, and 10) in the semantic task as compared to the perceptual task. We propose that memory processes are subserved by a wide neurocognitive network and that encoding processes involve preferential activation of the structures in the left inferior prefrontal cortex. PMID:8134340
Neuroanatomical correlates of encoding in episodic memory: levels of processing effect.
Kapur, S; Craik, F I; Tulving, E; Wilson, A A; Houle, S; Brown, G M
1994-03-15
Cognitive studies of memory processes demonstrate that memory for stimuli is a function of how they are encoded; stimuli processed semantically are better remembered than those processed in a perceptual or shallow fashion. This study investigates the neural correlates of this cognitive phenomenon. Twelve subjects performed two different cognitive tasks on a series of visually presented nouns. In one task, subjects detected the presence or absence of the letter a; in the other, subjects categorized each noun as living or nonliving. Positron emission tomography (PET) scans using 15O-labeled water were obtained during both tasks. Subjects showed substantially better recognition memory for nouns seen in the living/nonliving task, compared to nouns seen in the a-checking task. Comparison of the PET images between the two cognitive tasks revealed a significant activation in the left inferior prefrontal cortex (Brodmann's areas 45, 46, 47, and 10) in the semantic task as compared to the perceptual task. We propose that memory processes are subserved by a wide neurocognitive network and that encoding processes involve preferential activation of the structures in the left inferior prefrontal cortex.
Johnson, David R; Tian, Fang; Roman, Maxine J; Decker, Eric A; Goddard, Julie M
2015-05-27
Foods such as bulk oils, salad dressings, and nutritionally fortified beverages that are susceptible to oxidative degradation are often packaged in poly(ethylene terephthalate) (PET) bottles with metal chelators added to the food to maintain product quality. In the present work, a metal-chelating active packaging material is designed and characterized, in which poly(hydroxamic acid) (PHA) metal-chelating moieties were grafted from the surface of PET. Biomimetic PHA groups were grafted in a two-step UV-initiated process without the use of a photoinitiator. Surface characterization of the films by attenuated total reflective Fourier transform infrared spectroscopy (ATR-FTIR) and scanning electron microscopy (SEM) suggested successful grafting and conversion of poly(hydroxyethyl acrylate) (PHEA) to PHA chelating moieties from the surface of PET. Colorimetric (ferrozine) and inductively coupled plasma mass spectroscopy (ICP-MS) assays demonstrated the ability of PET-g-PHA to chelate iron in a low-pH (3.0) environment containing a competitive metal chelator (citric acid). Lipid oxidation studies demonstrated the antioxidant activity of PET-g-PHA films in inhibiting iron-promoted oxidation in an acidified oil-in-water (O/W) emulsion model system (pH 3.0). Particle size and ζ-potential analysis indicated that the addition of PET-g-PHA films did not affect the physical stability of the emulsion system. This work suggests that biomimetic chelating moieties can be grafted from PET and effectively inhibit iron-promoted degradation reactions, enabling removal of metal-chelating additives from product formulations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Pets. 1002.15 Section 1002.15....15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building, public... possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying visually impaired...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Pets. 1002.15 Section 1002.15....15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building, public... possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying visually impaired...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Pets. 1002.15 Section 1002.15....15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building, public... possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying visually impaired...
Impairment of nonverbal recognition in Alzheimer disease: a PET O-15 study.
Anderson, K E; Brickman, A M; Flynn, J; Scarmeas, N; Van Heertum, R; Sackeim, H; Marder, K S; Bell, K; Moeller, J R; Stern, Y
2007-07-03
To characterize deficits in nonverbal recognition memory and functional brain changes associated with these deficits in Alzheimer disease (AD). Using O-15 PET, we studied 11 patients with AD and 17 cognitively intact elders during the combined encoding and retrieval periods of a nonverbal recognition task. Both task conditions involved recognition of line drawings of abstract shapes. In both conditions, subjects were first presented a list of shapes as study items, and then a list as test items, containing items from the study list and foils. In the titrated demand condition, the shape study list size (SLS) was adjusted prior to imaging so that each subject performed at approximately 75% recognition accuracy; difficulty during PET scanning in this condition was approximately matched across subjects. A control task was used in which SLS = 1 shape. During performance of the titrated demand condition, SLS averaged 4.55 (+/-1.86) shapes for patients with AD and 7.53 (+/-4.81) for healthy elderly subjects (p = 0.031). However, both groups of subjects were closely matched on performance in the titrated demand condition during PET scanning with 72.17% (+/-7.98%) correct for patients with AD and 72.25% (+/-7.03%) for elders (p = 0.979). PET results demonstrated that patients with AD showed greater mean differences between the titrated demand condition and control in areas including the left fusiform and inferior frontal regions (Brodmann areas 19 and 45). Relative fusiform and inferior frontal differences may reflect the Alzheimer disease (AD) patients' compensatory engagement of alternate brain regions. The strategy used by patients with AD is likely to be a general mechanism of compensation, rather than task-specific.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Pets. 2.15 Section 2.15 Parks... USE AND RECREATION § 2.15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public... area closed to the possession of pets by the superintendent. This subparagraph shall not apply to guide...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Pets. 2.15 Section 2.15 Parks... USE AND RECREATION § 2.15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public... area closed to the possession of pets by the superintendent. This subparagraph shall not apply to guide...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 36 Parks, Forests, and Public Property 1 2013-07-01 2013-07-01 false Pets. 2.15 Section 2.15 Parks... USE AND RECREATION § 2.15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public... area closed to the possession of pets by the superintendent. This subparagraph shall not apply to guide...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Pets. 2.15 Section 2.15 Parks... USE AND RECREATION § 2.15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public... area closed to the possession of pets by the superintendent. This subparagraph shall not apply to guide...
Ibaraki, Masanobu; Shinohara, Yuki; Nakamura, Kazuhiro; Miura, Shuichi; Kinoshita, Fumiko; Kinoshita, Toshibumi
2010-07-01
Regional cerebral blood flow (CBF) and oxygen metabolism can be measured by positron emission tomography (PET) with (15)O-labeled compounds. Hemoglobin (Hb) concentration of blood, a primary determinant of arterial oxygen content (C(a)O(2)), influences cerebral circulation. We investigated interindividual variations of CBF, cerebral blood volume (CBV), oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO(2)) in relation to Hb concentration in healthy human volunteers (n=17) and in patients with unilateral steno-occlusive disease (n=44). For the patients, data obtained only from the contralateral hemisphere (normal side) were analyzed. The CBF and OEF were inversely correlated with Hb concentration, but CMRO(2) was independent of Hb concentration. Oxygen delivery defined as a product of C(a)O(2) and CBF (C(a)O(2) CBF) increased with a rise of Hb concentration. The analysis with a simple oxygen model showed that oxygen diffusion parameter (L) was constant over the range of Hb concentration, indicating that a homeostatic mechanism controlling CBF is necessary to maintain CMRO(2). The current findings provide important knowledge to understand the control mechanism of cerebral circulation and to interpret the (15)O PET data in clinical practice.
IHEKWEAZU, C.; CARROLL, K.; ADAK, B.; SMITH, G.; PRITCHARD, G. C.; GILLESPIE, I. A.; VERLANDER, N. Q.; HARVEY-VINCE, L.; REACHER, M.; EDEGHERE, O.; SULTAN, B.; COOPER, R.; MORGAN, G.; KINROSS, P. T. N.; BOXALL, N. S.; IVERSEN, A.; BICKLER, G.
2012-01-01
SUMMARY In the summer of 2009, an outbreak of verocytotoxigenic Escherichia coli O157 (VTEC O157) was identified in visitors to a large petting farm in South East England. The peak attack rate was 6/1000 visitors, and highest in those aged <2 years (16/1000). We conducted a case-control study with associated microbiological investigations, on human, animal and environmental samples. We identified 93 cases; 65 primary, 13 secondary and 15 asymptomatic. Cases were more likely to have visited a specific barn, stayed for prolonged periods and be infrequent farm visitors. The causative organism was identified as VTEC O157 PT21/28 with the same VNTR profile as that isolated in faecal specimens from farm animals and the physical environment, mostly in the same barn. Contact with farm livestock, especially ruminants, should be urgently reviewed at the earliest suspicion of a farm-related VTEC O157 outbreak and appropriate risk management procedures implemented without delay. PMID:22093751
Ihekweazu, C; Carroll, K; Adak, B; Smith, G; Pritchard, G C; Gillespie, I A; Verlander, N Q; Harvey-Vince, L; Reacher, M; Edeghere, O; Sultan, B; Cooper, R; Morgan, G; Kinross, P T N; Boxall, N S; Iversen, A; Bickler, G
2012-08-01
In the summer of 2009, an outbreak of verocytotoxigenic Escherichia coli O157 (VTEC O157) was identified in visitors to a large petting farm in South East England. The peak attack rate was 6/1000 visitors, and highest in those aged <2 years (16/1000). We conducted a case-control study with associated microbiological investigations, on human, animal and environmental samples. We identified 93 cases; 65 primary, 13 secondary and 15 asymptomatic. Cases were more likely to have visited a specific barn, stayed for prolonged periods and be infrequent farm visitors. The causative organism was identified as VTEC O157 PT21/28 with the same VNTR profile as that isolated in faecal specimens from farm animals and the physical environment, mostly in the same barn. Contact with farm livestock, especially ruminants, should be urgently reviewed at the earliest suspicion of a farm-related VTEC O157 outbreak and appropriate risk management procedures implemented without delay.
Goode, Brant; O'Reilly, Ciara; Dunn, John; Fullerton, Kathleen; Smith, Stacey; Ghneim, George; Keen, James; Durso, Lisa; Davies, Megan; Montgomery, Sue
2009-01-01
To identify cases, describe the outbreak, implement control measures, and identify factors associated with infection or protection from infection, including contact with animals and hand hygiene practices. Case finding, a case-control study of 45 cases and 188 controls, environmental investigation, and molecular subtyping of clinical and environmental Escherichia coli O157:H7 isolates. The 2004 North Carolina State Fair. Case patients were fair visitors who had laboratory-confirmed E coli O157 infections, hemolytic uremic syndrome (HUS) diagnoses, or bloody diarrheal illnesses. Control subjects were recruited from a randomized list of persons who had purchased fair tickets online. Environmental samples from the fairgrounds were obtained from locations that had held animals during the fair. Main Exposure Visiting a petting zoo. Case finding: Summary descriptive statistics of suspected, probable, or confirmed E coli O157:H7 infections, signs, symptoms, and HUS. Environmental investigation: E coli O157:H7 isolates, pulsed-field gel electrophoresis patterns, and spatial distribution of source locations. Case-control study: Odds ratios (ORs) comparing reported fair-related activities, hygiene practices, and zoonotic disease knowledge with outcome. A total of 108 case patients were ascertained, including 41 with laboratory-confirmed illness and 15 who experienced HUS. Forty-five case patients and 188 controls were enrolled in the case-control study. Visits to a petting zoo having substantial environmental E coli O157:H7 contamination were associated with illness (age-adjusted OR, 8.2; 95% confidence interval [CI], 3.3-20.3). Among children 5 years or younger who had visited the implicated petting zoo, contact with animal manure (OR, 6.9; 95% CI, 2.2-21.9) and hand-to-mouth behaviors (OR, 10.6; 95% CI, 2.0-55.0) were associated with illness. Reported hand hygiene practices did not differ significantly (OR, 1.8; 95% CI, 0.3-9.5). Reported awareness of the risk for zoonotic disease was protective (OR, 0.1; 95% CI, 0.03-0.5). Environmental samples from the petting zoo implicated in the case-control study yielded E coli O157:H7, with indistinguishable pulsed-field gel electrophoresis patterns from the predominant strain. We describe one of the largest petting zoo outbreaks of E coli O157:H7 to date. Persons became infected after contact with manure and engaging in hand-to-mouth behaviors in a petting zoo having substantial E coli O157:H7 contamination. Use of alcohol-based hand-sanitizing gels was not protective, although knowledge of the risk for zoonotic infection was protective. Future investigations in similar outbreaks should assess risks for infection and protective measures (eg, physical barriers separating visitors from animal manure, education, and appropriate hand hygiene practices).
NASA Astrophysics Data System (ADS)
Crespo, Paulo; Reis, João; Couceiro, Miguel; Blanco, Alberto; Ferreira, Nuno C.; Marques, Rui Ferreira; Martins, Paulo; Fonte, Paulo
2012-06-01
A single-bed, whole-body positron emission tomograph based on resistive plate chambers has been proposed (RPC-PET). An RPC-PET system with an axial field-of-view (AFOV) of 2.4 m has been shown in simulation to have higher system sensitivity using the NEMA NU2-1994 protocol than commercial PET scanners. However, that protocol does not correlate directly with lesion detectability. The latter is better correlated with the planar (slice) sensitivity, obtained with a NEMA NU2-2001 line-source phantom. After validation with published data for the GE Advance, Siemens TruePoint and TrueV, we study by simulation their axial sensitivity profiles, comparing results with RPC-PET. Planar sensitivities indicate that RPC-PET is expected to outperform 16-cm (22-cm) AFOV scanners by a factor 5.8 (3.0) for 70-cm-long scans. For 1.5-m scans (head to mid-legs), the sensitivity gain increases to 11.7 (6.7). Yet, PET systems with large AFOV provide larger coverage but also larger attenuation in the object. We studied these competing effects with both spherical- and line-sources immersed in a 27-cm-diameter water cylinder. For 1.5-m-long scans, the planar sensitivity drops one order of magnitude in all scanners, with RPC-PET outperforming 16-cm (22-cm) AFOV scanners by a factor 9.2 (5.3) without considering the TOF benefit. A gain in the effective sensitivity is expected with TOF iterative reconstruction. Finally, object scatter in an anthropomorphic phantom is similar for RPC-PET and modern, scintillator-based scanners, although RPC-PET benefits further if its TOF information is utilized to exclude scatter events occurring outside the anthropomorphic phantom.
Silverman, Daniel H S; Dy, Christine J; Castellon, Steven A; Lai, Jasmine; Pio, Betty S; Abraham, Laura; Waddell, Kari; Petersen, Laura; Phelps, Michael E; Ganz, Patricia A
2007-07-01
To explore the relationship of regional cerebral blood flow and metabolism with cognitive function and past exposure to chemotherapy for breast cancer. Subjects treated for breast cancer with adjuvant chemotherapy remotely (5-10 years previously) were studied with neuropsychologic testing and positron emission tomography (PET), and were compared with control subjects who had never received chemotherapy. [O-15] water PET scans was acquired during performance of control and memory-related tasks to evaluate cognition-related cerebral blood flow, and [F-18] fluorodeoxyglucose (FDG) PET scans were acquired to evaluate resting cerebral metabolism. PET scans were analyzed by statistical parametric mapping and region of interest methods of analysis. During performance of a short-term recall task, modulation of cerebral blood flow in specific regions of frontal cortex and cerebellum was significantly altered in chemotherapy-treated subjects. Cerebral activation in chemotherapy-treated subjects differed most significantly from untreated subjects in inferior frontal gyrus, and resting metabolism in this area correlated with performance on a short-term memory task previously found to be particularly impaired in chemotherapy-treated subjects. In examining drug-class specific effects, metabolism of the basal ganglia was significantly decreased in tamoxifen + chemotherapy-treated patients compared with chemotherapy-only breast cancer subjects or with subjects who had not received chemotherapy, while chemotherapy alone was not associated with decreased basal ganglia activity relative to untreated subjects. Specific alterations in activity of frontal cortex, cerebellum, and basal ganglia in breast cancer survivors were documented by functional neuroimaging 5-10 years after completion of chemotherapy.
NASA Astrophysics Data System (ADS)
Heitmann, Emma O.; Ji, Shunchuan; Nie, Junsheng; Breecker, Daniel O.
2017-09-01
Middle Miocene Earth had several boundary conditions similar to those predicted for future Earth including similar atmospheric pCO2 and substantial Antarctic ice cover but no northern hemisphere ice sheets. We describe a 12 m outcrop of the terrestrial Yanwan Section in the Tianshui Basin, Gansu, China, following the Miocene Climate Transition (13.9-13.7 Ma). It consists of ∼25 cm thick CaCO3-cemented horizons that overprint siltstones every ∼1 m. We suggest that stacked soils developed in siltstones under a seasonal climate with a fluctuating water table, evidenced by roots, clay films, mottling, presence of CaCO3 nodules, and stacked carbonate nodule δ13 C and δ18 O profiles that mimic modern soils. We suggest that the CaCO3-cemented horizons are capillary-fringe carbonates that formed in an arid climate with a steady water table and high potential evapotranspiration rates (PET), evidenced by sharp upper and basal contacts, micrite, sparite, and root-pore cements. The CaCO3 of the cemented horizons and the carbonate nodules have similar mean δ18 O and δ13 C values but the cements have significantly smaller variance in δ13 C and δ18 O values and a different δ18 O versus δ13 C slope, supporting the conclusion that these carbonates are from different populations. The magneto-stratigraphic age model indicates obliquity pacing of the arid conditions required to form the CaCO3-cemented horizons suggesting an orbital control on water availability. We suggest two possible drivers for the obliquity pacing of arid conditions: 1) variability in the cross-equatorial pressure gradient that controls summer monsoon (ASM) strength and is influenced by obliquity-paced variations of Antarctic ice volume and 2) variability in Western Pacific Ocean-East Asian continent pressure gradient controlled by the 25-45°N meridional insolation gradient. We also suggest that variations in aridity were influenced by variations in PET and sensible heating of the regional land surface which are both influenced by precession-controlled 35°N summer insolation. We then use orbital configurations to predict lithology. Coincidence of obliquity minima (strong ASM) and 35°N summer insolation maxima (strong ASM) drives strong ASM and high PET, resulting in soil formation in an environment with relatively large seasonal changes in water availability. Coincidence of obliquity maxima (weak ASM) and 35°N summer insolation maxima (strong ASM) moderates the ASM, results in high PET, and thus drives overprinting of soils by capillary fringe carbonates above a deepened and relatively stable water table. Coincidence of obliquity and insolation minima also moderates the ASM but results in low PET and thus a high water table, which explains the previously documented occurrence of aquatic plants in this section. This context allows us to assign an orbital configuration to atmospheric pCO2 determined from the paleosols. Our best estimate of pCO2 during the times of intermediate ice volume is 475 + 650 / - 230 ppmV (median value with error reported as 84th-16th percentile values). Southern hemisphere control of ASM variability during the Middle Miocene may have resulted in larger orbital scale water availability variations compared with the Pleistocene.
Mirzaei, Alireza; Jalilian, Amir R; Akhlaghi, Mehdi; Beiki, Davood
2016-01-01
Gallium-68 citrate has been successfully applied in the PET imaging of infections and inflammation in some centers; however further evaluation of the tracer in inflammation models is of great importance. 68Ga-citrate prepared from [68Ga]GaCl3 (eluted form an SnO2 based 68Ge/68Ga generator) and sodium citrate at optimized conditions followed by quality control tests was injected to normal and turpentine-oil induced rats PET/CT imaging studies up to 290 min. 68Ga-citrate was prepared with acceptable radiochemical purity (>99 ITLC, >99% HPLC), specific activity (28-30 GBq/mM), chemical purity (Sn, Fe <0.3 ppm; Zn<0.2 ppm) in 15 min at 50°C. PET/CT imaging of the tracer demonstrated early detection of inflamed site in animal models in 60-80 min. This study demonstrated possible early detection of inflammation foci in vivo using 68Ga-citrate prepared using commercially available 68Ge/68Ga generators for PET imaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Ferrieri, R.A.; Schlyer, D.J.; Shea, C.
1995-06-13
A process for simultaneously producing PET-usable quantities of [{sup 13}N]NH{sub 3} and [{sup 18}F]F{sup {minus}} for radiotracer synthesis is disclosed. The process includes producing [{sup 13}N]NO{sub 2}{sup {minus}}/NO{sub 3}{sup {minus}}and [{sup 18}F]F{sup {minus}} simultaneously by exposing a low-enriched (20%-30%) [{sup 18}O]H{sub 2}O target to proton irradiation, sequentially isolating the [{sup 13}N]NO{sub 2}{sup {minus}}/NO{sub 3}{sup {minus}} and [{sup 18}F]F{sup {minus}} from the [{sup 18}O]H{sub 2}O target, and reducing the [{sup 13}N]NO{sub 2}{sup {minus}}/NO{sub 3}{sup {minus}} to [{sup 13}N]NH{sub 3}. The [{sup 13}N]NH{sub 3} and [{sup 18}F]F{sup {minus}} products are then conveyed to a laboratory for radiotracer applications. The process employs an anion exchange resin for isolation of the isotopes from the [{sup 18}O]H{sub 2}O, and sequential elution of [{sup 13}N]NO{sub 2}{sup {minus}}/NO{sub 3}{sup {minus}} and [{sup 18}F]F{sup {minus}} fractions. Also the apparatus is disclosed for simultaneously producing PET-usable quantities of [{sup 13}N]NH{sub 3} and [{sup 18}F]F{sup {minus}} from a single irradiation of a single low-enriched [{sup 18}O]H{sub 2}O target. 2 figs.
Han, Zhenzhen; Wang, Yao; Wang, Jiuxing; Wang, Shichao; Zhuang, Hongwei; Liu, Jixian; Huang, Linjun; Wang, Yanxin; Wang, Wei; Belfiore, Laurence A.; Tang, Jianguo
2018-01-01
In this research contribution, the primary objective was to enhance the crystallization behavior of poly(ethylene terephthalate) (PET). To accomplish this tack, three kinds of new nucleating agents SiO2-diethylene glycol-LMPET (PET-3), SiO2-triethylene glycol–LMPET(PET-4) and SiO2-tetraethylene glycol-LMPET (PET-5) nucleating agents were prepared via grafting different oligomers (diethylene glycol; triethylene glycol and tetraethylene glycol) to the surface of nano-SiO2 and then linking to the low molecular weight poly(ethylene terephthalate) (LMPET). These nano-particle nucleating agents facilitated the crystallization of PET. Differential scanning calorimetry (DSC) studies of the composites that pure PET blended with PET-3, PET-4 and PET-5 indicated that the longer ethoxy segment in the nucleating agents exhibited (i) higher degrees of crystallinity; (ii) faster rates of crystallization; and (iii) higher crystallization temperatures. The Jeziorny method was employed to analyze the non-isothermal crystallization kinetics of the composites. These works demonstrated that the PET-3, PET-4 and PET-5 were attractive nucleating agents for poly(ethylene terephthalate), and the longer the chain length of the ethoxy segment in the nucleating agents, the more efficient the nucleation effect. PMID:29641456
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Pets. 1002.15 Section 1002.15 Parks, Forests, and Public Property PRESIDIO TRUST RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 1002.15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building, public...
NASA Astrophysics Data System (ADS)
Wegmann, K.; Adam, L.-E.; Livieratos, L.; Zaers, J.; Bailey, D. L.; Brix, G.
1999-08-01
The fraction of detected scattered radiation in transmission measurements with a single photon transmission (SPT) source of Cesium-137 was investigated by means of Monte Carlo (MC) techniques. The scatter contamination was determined for different energy thresholds and the use of interplane septa. The simulations were validated with measurements performed at the whole-body 3D PET scanner ECAT EXACT 3D (CTI/Siemens, Knoxville, TN), which uses a SPT source. The comparison of the results from the simulations and the measurements shows good agreement. Transmission through a water-filled cylinder (o=20 cm) gave values of the scatter fraction SF of about 27% at a lower level discriminator (LLD) value of 500 keV in the center of the projection. A reduction to 17% was achieved by an increase of the LLD to 600 keV; a relative decrease of 37%. But a corresponding loss of counts by a factor of 1.5 was observed. Furthermore, simulations of the ECAT EXACT HR/sup +/ have been performed, a whale-body PET scanner which can be operated in 2D and 3D mode, but has no SPT mode yet. At a value of the LLD of 500 keV, the simulations showed a decrease of the SF in the 2D mode of 45% relative to the 3D mode for the transmission of the water-filled cylinder.
Sex differences in absolute myocardial perfusion. Non-invasive H2(15)O-PET in young healthy adults.
Range, Felix T; Kies, Peter; Schäfers, Klaus P; Breithardt, Günter; Schober, Otmar; Wichter, Thomas; Schäfers, Michael A
2016-09-26
To investigate sex differences in myocardial perfusion especially in healthy individuals since former studies are rare and findings are controversial. Participants, methods: 26 subjects were enrolled: 16 healthy women (age: 34 ±7 years) were compared with 10 healthy men (age: 34 ± 3 years; p = ns). Myocardial blood flow (MBF) and coronary vascular resistance (CVR) were quantified at rest, during adenosine infusion and cold-pressor-testing, using positron emission tomography and radioactive-labelled water (H2(15)O-PET). Women showed higher MBF than men at rest (1.10 ± 0.18 vs. 0.85 ± 0.20 ml/min/ml; p = 0.003) and cold-stress (1.39 ± 0.38 vs. 1.06 ± 0.28 ml/min/ml; p = 0.026). Corrected for rate-pressure-product, baseline findings maintained significance (1.41 ± 0.33 vs. 1.16 ± 0.19 ml/min/ml; p = 0.024). CVR was lower in women at baseline (81 ± 14 vs. 107 ± 22 mmHg*ml(-1)*min*ml; p = 0.006) and during cold-pressor-testing (71 ± 17 vs. 91 ± 20 mmHg*ml(-1)*min*ml; p = 0.013). Under adenosine neither maximal MBF (4.06 ± 1.0 vs. 3.91 ± 0.88 ml/min/ml; p = ns) nor coronary flow reserve (3.07 ± 1.12 vs. 3.44 ± 0.92; p = ns) nor CVR (24 ± 8 vs. 24 ± 6 mmHg*ml(-1)*min*ml; p = ns) showed sex-related differences. Women show higher myocardial perfusion and lower coronary vascular resistance than men in physiologic states. Maximum perfusion and vasodilation under adenosine are not sex-specific.
NASA Astrophysics Data System (ADS)
Azmi, N. B.; Khalid, F. S.; Irwan, J. M.; Mazenan, P. N.; Zahir, Z.; Shahidan, S.
2018-04-01
This study is focuses to the performance of composite sand cement brick containing recycle concrete aggregate and waste polyethylene terephthalate. The objective is to determine the mechanical properties such as compressive strength and water absorption of composite brick containing recycled concrete aggregate and polyethylene terephthalate waste and to determine the optimum mix ratio of bricks containing recycled concrete aggregate and polyethylene terephthalate waste. The bricks specimens were prepared by using 100% natural sand, they were then replaced by RCA at 25%, 50% and 75% with proportions of PET consists of 1.0%, 1.5%, 2.0% and 2.5% by weight of natural sand. Based on the results of compressive strength, it indicates that the replacement of RCA shows an increasing strength as the strength starts to increase from 25% to 50% for both mix design ratio. The strength for RCA 75% volume of replacement started to decrease as the volume of PET increase. However, the result of water absorption with 50% RCA and 1.0% PET show less permeable compared to control brick at both mix design ratio. Thus, one would expect the density of brick decrease and the water absorption to increase as the RCA and PET content is increased.
MEG Frequency Analysis Depicts the Impaired Neurophysiological Condition of Ischemic Brain
Ikeda, Hidetoshi; Tsuyuguchi, Naohiro; Uda, Takehiro; Okumura, Eiichi; Asakawa, Takashi; Haruta, Yasuhiro; Nishiyama, Hideki; Okada, Toyoji; Kamada, Hajime; Ohata, Kenji; Miki, Yukio
2016-01-01
Purpose Quantitative imaging of neuromagnetic fields based on automated region of interest (ROI) setting was analyzed to determine the characteristics of cerebral neural activity in ischemic areas. Methods Magnetoencephalography (MEG) was used to evaluate spontaneous neuromagnetic fields in the ischemic areas of 37 patients with unilateral internal carotid artery (ICA) occlusive disease. Voxel-based time-averaged intensity of slow waves was obtained in two frequency bands (0.3–4 Hz and 4–8 Hz) using standardized low-resolution brain electromagnetic tomography (sLORETA) modified for a quantifiable method (sLORETA-qm). ROIs were automatically applied to the anterior cerebral artery (ACA), anterior middle cerebral artery (MCAa), posterior middle cerebral artery (MCAp), and posterior cerebral artery (PCA) using statistical parametric mapping (SPM). Positron emission tomography with 15O-gas inhalation (15O-PET) was also performed to evaluate cerebral blood flow (CBF) and oxygen extraction fraction (OEF). Statistical analyses were performed using laterality index of MEG and 15O-PET in each ROI with respect to distribution and intensity. Results MEG revealed statistically significant laterality in affected MCA regions, including 4–8 Hz waves in MCAa, and 0.3–4 Hz and 4–8 Hz waves in MCAp (95% confidence interval: 0.020–0.190, 0.030–0.207, and 0.034–0.213), respectively. We found that 0.3–4 Hz waves in MCAp were highly correlated with CBF in MCAa and MCAp (r = 0.74, r = 0.68, respectively), whereas 4–8 Hz waves were moderately correlated with CBF in both the MCAa and MCAp (r = 0.60, r = 0.63, respectively). We also found that 4–8 Hz waves in MCAp were statistically significant for misery perfusion identified on 15O-PET (p<0.05). Conclusions Quantitatively imaged spontaneous neuromagnetic fields using the automated ROI setting enabled clear depiction of cerebral ischemic areas. Frequency analysis may reveal unique neural activity that is distributed in the impaired vascular metabolic territory, in which the cerebral infarction has not yet been completed. PMID:27992543
Code of Federal Regulations, 2013 CFR
2013-07-01
... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Pets. § 1002.15 Section Â... RECREATION § 1002.15 Pets. (a) The following are prohibited: (1) Possessing a pet in a public building... closed to the possession of pets by the Board. This paragraph shall not apply to guide dogs accompanying...
NASA Technical Reports Server (NTRS)
Jaffe, Richard; Han, Jie; Yoon, Do; Langhoff, Stephen R. (Technical Monitor)
1997-01-01
The so-called oxygen gauche effect in poly(oxyethylene) (POE) and its model molecules such as 1,2-dimethoxyethane (DME) and diglyme (CH3OC2H4OC2H4OCH3) is manifested in the preference for gauche C-C bond conformations over trans. This has also been observed for poly(ethylene terephthalate) (PET). Our previous quantum chemistry calculations demonstrated that the large C-C gauche population in DME is due, in part, to a low-lying tg +/- g+ conformer that exhibits a substantial 1,5 CH ... O attraction. New calculations will be described that demonstrate the accuracy of the original quantum chemistry calculations. In addition, an extension of this work to model molecules for PET will be presented. It is seen that the C-C gauche preference is much stronger in 1,2 diacetoxyethane than in DME. In addition, there exist low-lying tg +/- g+/- and g+/-g+/-g+/- conformers that exhibit 1,5 CH ... O attractions involving the carbonyl oxygens. It is expected that the -O-C-C-O- torsional properties will be quite different in these two polymers. The quantum chemistry results are used to parameterize rotational isomeric states models (RIS) and force fields for molecular dynamics simulations of these polymers.
Highly Transparent and UV-Resistant Superhydrophobic SiO2-Coated ZnO Nanorod Arrays
2015-01-01
Highly transparent and UV-resistant superhydrophobic arrays of SiO2-coated ZnO nanorods are prepared in a sequence of low-temperature (<150 °C) steps on both glass and thin sheets of PET (2 × 2 in.2), and the superhydrophobic nanocomposite is shown to have minimal impact on solar cell device performance under AM1.5G illumination. Flexible plastics can serve as front cell and backing materials in the manufacture of flexible displays and solar cells. PMID:24495100
SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, T; Hamacher, K
2016-06-15
Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET andmore » CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.« less
Low thermal budget, photonic-cured compact TiO 2 layers for high-efficiency perovskite solar cells
Das, Sanjib; Gu, Gong; Joshi, Pooran C.; ...
2016-05-25
Rapid advances in organometallic trihalide perovskite solar cells (PSCs) have positioned them to be one of the leading next generation photovoltaic technologies. However, most of the high-performance PSCs, particularly those using compact TiO 2 as an electron transport layer, require a high-temperature sintering step, which is not compatible with flexible polymer-based substrates. Considering the materials of interest for PSCs and corresponding device configurations, it is technologically imperative to fabricate high-efficiency cells at low thermal budget so that they can be realized on low-temperature plastic substrates. In this paper, we report on a new photonic curing technique that produces crystalline anatase-phasemore » TiO 2 films on indium tin oxide-coated glass and flexible polyethylene terephthalate (PET) substrates. Finally, the planar PSCs, using photonic-cured TiO 2 films, exhibit PCEs as high as 15.0% and 11.2% on glass and flexible PET substrates, respectively, comparable to the device performance of PSCs incorporating furnace annealed TiO 2 films.« less
Janek Strååt, Sara; Jacobsson, Hans; Noz, Marilyn E; Andreassen, Björn; Näslund, Ingemar; Jonsson, Cathrine
2013-01-23
The purpose of this work was to reveal the research interest value of positron emission tomography (PET) imaging in visualizing the induced tissue activity post high-energy photon radiation treatment. More specifically, the focus was on the possibility of retrieving data such as tissue composition and physical half-lives from dynamic PET acquisitions, as positron-emitting radionuclides such as 15O, 11C, and 13N are produced in vivo during radiation treatment with high-energy photons (>15 MeV). The type, amount, and distribution of induced positron-emitting radionuclides depend on the irradiated tissue cross section, the photon spectrum, and the possible perfusion-driven washout. A 62-year-old man diagnosed with prostate cancer was referred for palliative radiation treatment of the pelvis minor. A total dose of 8 Gy was given using high-energy photon beams (50 MV) with a racetrack microtron, and 7 min after the end of irradiation, the patient was positioned in a PET/computed tomography (CT) camera, and a list-mode acquisition was performed for 30 min. Two volumes of interests (VOIs) were positioned on the dynamic PET/CT images, one in the urinary bladder and the other in the subcutaneous fat. Analysis of the measured relative count rate was performed in order to compute the tissue compositions and physical half-lives in the two regions. Dynamic analysis from the two VOIs showed that the decay constants of activated oxygen and carbon could be deduced. Calculation of tissue composition from analyzing the VOI containing subcutaneous fat only moderately agreed with that of the tabulated International Commission on Radiation Units & Measurements (ICRU) data of the adipose tissue. However, the same analysis for the bladder showed a good agreement with that of the tabulated ICRU data. PET can be used in visualizing the induced activity post high-energy photon radiation treatment. Despite the very low count rate in this specific application, wherein 7 min after treatment was about 5% of that of a standard 18F-FDG PET scan, the distribution of activated tissue elements (15O and 11C) could be calculated from the dynamic PET data. One possible future application of this method could possibly be to measure and determine the tumor tissue composition in order to identify any hypoxic or necrotic region, which is information that can be used in the ongoing therapy planning process. The official name of the trial committee of this study is 'Regionala etikprövningsnämnden i Stockholm' (FE 289, Stockholm, SE-17177, Sweden). The unique identifying number is 2011/1789-31/2.
Mizukawa, Hazuki; Nomiyama, Kei; Nakatsu, Susumu; Iwata, Hisato; Yoo, Jean; Kubota, Akira; Yamamoto, Miyuki; Ishizuka, Mayumi; Ikenaka, Yoshinori; Nakayama, Shouta M M; Kunisue, Tatsuya; Tanabe, Shinsuke
2016-01-05
There are growing concerns about the increase in hyperthyroidism in pet cats due to exposure to organohalogen contaminants and their hydroxylated metabolites. This study investigated the blood contaminants polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) and their hydroxylated and methoxylated derivatives (OH-PCBs, OH-PBDEs, and MeO-PBDEs), in pet dogs and cats. We also measured the residue levels of these compounds in commercially available pet foods. Chemical analyses of PCBs and OH-PCBs showed that the OH-PCB levels were 1 to 2 orders of magnitude lower in cat and dog food products than in their blood, suggesting that the origin of OH-PCBs in pet dogs and cats is PCBs ingested with their food. The major congeners of OH-/MeO-PBDEs identified in both pet food products and blood were natural products (6OH-/MeO-BDE47 and 2'OH-/MeO-BDE68) from marine organisms. In particular, higher concentrations of 6OH-BDE47 than 2'OH-BDE68 and two MeO-PBDE congeners were observed in the cat blood, although MeO-BDEs were dominant in cat foods, suggesting the efficient biotransformation of 6OH-BDE47 from 6MeO-BDE47 in cats. We performed in vitro demethylation experiments to confirm the biotransformation of MeO-PBDEs to OH-PBDEs using liver microsomes. The results showed that 6MeO-BDE47 and 2'MeO-BDE68 were demethylated to 6OH-BDE47 and 2'OH-BDE68 in both animals, whereas no hydroxylated metabolite from BDE47 was detected. The present study suggests that pet cats are exposed to MeO-PBDEs through cat food products containing fish flavors and that the OH-PBDEs in cat blood are derived from the CYP-dependent demethylation of naturally occurring MeO-PBDE congeners, not from the hydroxylation of PBDEs.
Ferrieri, Richard A.; Schlyer, David J.; Alexoff, David
1996-01-09
A handling and processing apparatus for preparing Oxygen-15 labeled water (H.sub.2 [.sup.15 O]) in injectable form for use in Positron Emission Tomography from preferably H.sub.2 [.sup.15 O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H.sub.2 [.sup.15 O] gas and impurities, mainly ammonia (NH.sub.3) gas into sterile water to trap the H.sub.2 [.sup.15 O] and form ammonium (NH.sub.4.sup.+) in the sterile water. A device for displacing the sterile water containing H.sub.2 [.sup.15 O] and NH.sub.4.sup.+ through a cation resin removes NH.sub.4.sup.+ from the sterile water. A device for combining the sterile water containing H.sub.2 [.sup.15 O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H.sub.2 [.sup.15 O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature.
Independent component model for cognitive functions of multiple subjects using [15O]H2O PET images.
Park, Hae-Jeong; Kim, Jae-Jin; Youn, Tak; Lee, Dong Soo; Lee, Myung Chul; Kwon, Jun Soo
2003-04-01
An independent component model of multiple subjects' positron emission tomography (PET) images is proposed to explore the overall functional components involved in a task and to explain subject specific variations of metabolic activities under altered experimental conditions utilizing the Independent component analysis (ICA) concept. As PET images represent time-compressed activities of several cognitive components, we derived a mathematical model to decompose functional components from cross-sectional images based on two fundamental hypotheses: (1) all subjects share basic functional components that are common to subjects and spatially independent of each other in relation to the given experimental task, and (2) all subjects share common functional components throughout tasks which are also spatially independent. The variations of hemodynamic activities according to subjects or tasks can be explained by the variations in the usage weight of the functional components. We investigated the plausibility of the model using serial cognitive experiments of simple object perception, object recognition, two-back working memory, and divided attention of a syntactic process. We found that the independent component model satisfactorily explained the functional components involved in the task and discuss here the application of ICA in multiple subjects' PET images to explore the functional association of brain activations. Copyright 2003 Wiley-Liss, Inc.
Tritium in [15O]water, its identification and removal.
Sasaki, T; Ishii, S; Tomiyoshi, K; Ido, T; Miyauchi, J; Senda, M
2000-02-01
The present investigation was undertaken to identify the long-lived radionuclide and its chemical forms existing in [15O]water which was synthesized from 15O produced by the nuclear reaction 14N(d,n)15O, and to develop a method for its removal to facilitate radioactive waste disposal. The long-lived nuclide was identified as tritium based on a comparison of its physical half-life and the energy spectrum of beta-rays with those of tritium. The major chemical form of tritium in the target gas was estimated to be molecular hydrogen. The tritium radioactivity was completely removed without a serious loss occurring to the yield of [15O]water by passing the irradiated target gas over a heated palladium catalyst followed by a calcium chloride column before the final synthesis of the [15O]water. This provided a practical way of removing tritium from the [15O]water.
NASA Astrophysics Data System (ADS)
Sheikh Khalid, Faisal; Bazilah Azmi, Nurul; Natasya Mazenan, Puteri; Shahidan, Shahiron; Ali, Noorwirdawati
2018-03-01
This research focuses on the performance of composite sand cement brick containing recycle concrete aggregate and waste polyethylene terephthalate. This study aims to determine the mechanical properties such as compressive strength and water absorption of composite brick containing recycled concrete aggregate (RCA) and polyethylene terephthalate (PET) waste. The bricks specimens were prepared by using 100% natural sand, they were then replaced by RCA at 25%, 50% and 75% with proportions of PET consists of 0.5%, 1.0% and 1.5% by weight of natural sand. Based on the results of compressive strength, only RCA 25% with 0.5% PET achieve lower strength than normal bricks while others showed a high strength. However, all design mix reaches strength more than 7N/mm2 as expected. Besides that, the most favorable mix design that achieves high compressive strength is 75% of RCA with 0.5% PET.
Preparation of ZnO nanorods on conductive PET-ITO-Ag fibers
NASA Astrophysics Data System (ADS)
Li, Yiwen; Ji, Shuai; Chen, Yuanyu; Zhang, Hong; Gong, Yumei; Guo, Jing
2016-12-01
We studied the vertical ZnO nanorods grown on conductive conventional polyethylene terephthalate (PET) fibers which are prepared by electroless silver depositing on tin-doped indium oxide (ITO) coated PET fibers through an efficient and low-cost green approach. The PET fibers were firstly functionalized with a layer of ITO gel synthesized through a sol-gel process at rather low temperature, simply by immersing the fibers into ITO sol for several minutes followed by gelation at 120 °C. Once the ITO gel layer surface was activated by SnCl2, a continuous, uniform, and compact layer of silver was carried out on the surface of the PET-ITO fibers through electroless plating operation at room temperature. The as-prepared PET-ITO-Ag fibers had good electrical conductivity, with surface resistivity as low as 0.23 mΩ cm. The overall procedure is simple, efficient, nontoxic, and controllable. The conductive PET-ITO-Ag fiber was used successfully as a flexible basal material to plant vertical ZnO nanorods through controlling the seeding and growth processes. The morphology of the PET-ITO, PET-ITO-Ag, and PET-ITO-Ag-ZnO fibers were observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Undergone the whole process, although the tensile strength of the fiber decreased slightly, they may still exert their applications in flexible electronic such as photovoltaic and piezoelectric devices.
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Ferrieri, R.A.; Schlyer, D.J.; Alexoff, D.
1996-01-09
A handling and processing apparatus is revealed for preparing Oxygen-15 labeled water (H{sub 2}[{sup 15}O]) in injectable form for use in Positron Emission Tomography from preferably H{sub 2}[{sup 15}O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H{sub 2}[{sup 15}O] gas and impurities, mainly ammonia (NH{sub 3}) gas into sterile water to trap the H{sub 2}[{sup 15}O] and form ammonium (NH{sub 4}{sup +}) in the sterile water. A device for displacing the sterile water containing H{sub 2}[{sup 15}O] and NH{sub 4}{sup +} through a cation resin removes NH{sub 4}{sup +} from the sterile water. A device for combining the sterile water containing H{sub 2}[{sup 15}O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H{sub 2}[{sup 15}O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature. 7 figs.
Albano, C; Camacho, N; Hernández, M; Matheus, A; Gutiérrez, A
2009-10-01
The goal of this work was to study the mechanical behavior of concrete with recycled Polyethylene Therephtalate (PET), varying the water/cement ratio (0.50 and 0.60), PET content (10 and 20 vol%) and the particle size. Also, the influence of the thermal degradation of PET in the concrete was studied, when the blends were exposed to different temperatures (200, 400, 600 degrees C). Results indicate that PET-filled concrete, when volume proportion and particle size of PET increased, showed a decrease in compressive strength, splitting tensile strength, modulus of elasticity and ultrasonic pulse velocity; however, the water absorption increased. On the other hand, the flexural strength of concrete-PET when exposed to a heat source was strongly dependent on the temperature, water/cement ratio, as well as on the PET content and particle size. Moreover, the activation energy was affected by the temperature, PET particles location on the slabs and water/cement ratio.
Thin transparent titania (TiO2) films were coated on the surface of flexible poly (ethylene terephthalate) (PET) surface using standard sol gel techniques. The TiO2/PET thin film surfaces were further modified by exposing the films to a RF glow discharge oxygen plasma. The exposu...
In situ synthesis of TiO2/polyethylene terephthalate hybrid nanocomposites at low temperature
NASA Astrophysics Data System (ADS)
Peng, Xinyan; Ding, Enyong; Xue, Feng
2012-06-01
TiO2 nanoflowers were in situ grown on polyethylene terephthalate (PET) non-woven fabric by hydrolysis of TiCl4 in aqueous solution in the presence of nanocrystal cellulose grafted PET fabric (NCC-g-PET) at a low temperature of 70 °C. Nanocrystal cellulose (NCC) pre-grafted on PET fabric acted as hydrophilic substrate and morphology inducing agent to promote the nucleation and crystal growth of TiO2. Detailed information on the synthetic process was presented. The resulting samples were characterized using FE-SEM, EDS, ATR-IR, Raman microscopy, XRD and TG analysis. The photocatalytic activity of the samples was evaluated by the degradation of orange methyl under solar light. Characteristic results indicate that rutile TiO2 nanoflowers have grown abundantly on PET non-woven fabric, and the established hydrogen bonding strengthens the interfacial interaction between the inorganic particles and the polymeric substrates. The methyl orange decoloration test under natural solar light demonstrates that this TiO2/PET hybrid nanocomposites exhibit excellent self-cleaning performance which is expected to have a good potential for commercialization.
Isolation of Escherichia coli 0157:H7 Strain from Fecal Samples of Zoo Animal
Mohammed Hamzah, Aseel; Mohammed Hussein, Aseel; Mahmoud Khalef, Jenan
2013-01-01
The isolation and characterization of Escherichia coli O157:H7 strains from 22 out of 174 fecal samples from petting zoo animals representing twenty-two different species (camel, lion, goats, zebra, bear, baboon monkey, Siberian monkey, deer, elk, llama, pony, horses, fox, kangaroo, wolf, porcupine, chickens, tiger, ostrich, hyena, dogs, and wildcats) were investigated. One petting Al-Zawraa zoological society of Baghdad was investigated for E. coli O157:H7 over a 16-month period that spanned two summer and two autumn seasons. Variation in the occurrence of E. coli O157:H7-positive petting zoo animals was observed, with animals being culture positive only in the summer months but not in the spring, autumn, or winter. E. coli O157:H7 isolates were distinguished by agglutination with E. coli O157:H7 latex reagent (Oxoid), identified among the isolates, which showed that multiple E. coli strains were isolated from one petting zoo animal, in which a single animal simultaneously shed multiple E. coli strains; E. coli O157:H7 was isolated only by selective enrichment culture of 2 g of petting zoo animal feces. In contrast, strains other than O157:H7 were cultured from feces of petting zoo animals without enrichment. PMID:24489514
Isolation of Escherichia coli 0157:H7 strain from fecal samples of zoo animal.
Mohammed Hamzah, Aseel; Mohammed Hussein, Aseel; Mahmoud Khalef, Jenan
2013-01-01
The isolation and characterization of Escherichia coli O157:H7 strains from 22 out of 174 fecal samples from petting zoo animals representing twenty-two different species (camel, lion, goats, zebra, bear, baboon monkey, Siberian monkey, deer, elk, llama, pony, horses, fox, kangaroo, wolf, porcupine, chickens, tiger, ostrich, hyena, dogs, and wildcats) were investigated. One petting Al-Zawraa zoological society of Baghdad was investigated for E. coli O157:H7 over a 16-month period that spanned two summer and two autumn seasons. Variation in the occurrence of E. coli O157:H7-positive petting zoo animals was observed, with animals being culture positive only in the summer months but not in the spring, autumn, or winter. E. coli O157:H7 isolates were distinguished by agglutination with E. coli O157:H7 latex reagent (Oxoid), identified among the isolates, which showed that multiple E. coli strains were isolated from one petting zoo animal, in which a single animal simultaneously shed multiple E. coli strains; E. coli O157:H7 was isolated only by selective enrichment culture of 2 g of petting zoo animal feces. In contrast, strains other than O157:H7 were cultured from feces of petting zoo animals without enrichment.
Dysfunctional role of parietal lobe during self-face recognition in schizophrenia.
Yun, Je-Yeon; Hur, Ji-Won; Jung, Wi Hoon; Jang, Joon Hwan; Youn, Tak; Kang, Do-Hyung; Park, Sohee; Kwon, Jun Soo
2014-01-01
Anomalous sense of self is central to schizophrenia yet difficult to demonstrate empirically. The present study examined the effective neural network connectivity underlying self-face recognition in patients with schizophrenia (SZ) using [15O]H2O Positron Emission Tomography (PET) and Structural Equation Modeling. Eight SZ and eight age-matched healthy controls (CO) underwent six consecutive [15O]H2O PET scans during self-face (SF) and famous face (FF) recognition blocks, each of which was repeated three times. There were no behavioral performance differences between the SF and FF blocks in SZ. Moreover, voxel-based analyses of data from SZ revealed no significant differences in the regional cerebral blood flow (rCBF) levels between the SF and FF recognition conditions. Further effective connectivity analyses for SZ also showed a similar pattern of effective connectivity network across the SF and FF recognition. On the other hand, comparison of SF recognition effective connectivity network between SZ and CO demonstrated significantly attenuated effective connectivity strength not only between the right supramarginal gyrus and left inferior temporal gyrus, but also between the cuneus and right medial prefrontal cortex in SZ. These findings support a conceptual model that posits a causal relationship between disrupted self-other discrimination and attenuated effective connectivity among the right supramarginal gyrus, cuneus, and prefronto-temporal brain areas involved in the SF recognition network of SZ. © 2013.
Hawe, David; Hernández Fernández, Francisco R; O'Suilleabháin, Liam; Huang, Jian; Wolsztynski, Eric; O'Sullivan, Finbarr
2012-05-01
In dynamic mode, positron emission tomography (PET) can be used to track the evolution of injected radio-labelled molecules in living tissue. This is a powerful diagnostic imaging technique that provides a unique opportunity to probe the status of healthy and pathological tissue by examining how it processes substrates. The spatial aspect of PET is well established in the computational statistics literature. This article focuses on its temporal aspect. The interpretation of PET time-course data is complicated because the measured signal is a combination of vascular delivery and tissue retention effects. If the arterial time-course is known, the tissue time-course can typically be expressed in terms of a linear convolution between the arterial time-course and the tissue residue. In statistical terms, the residue function is essentially a survival function - a familiar life-time data construct. Kinetic analysis of PET data is concerned with estimation of the residue and associated functionals such as flow, flux, volume of distribution and transit time summaries. This review emphasises a nonparametric approach to the estimation of the residue based on a piecewise linear form. Rapid implementation of this by quadratic programming is described. The approach provides a reference for statistical assessment of widely used one- and two-compartmental model forms. We illustrate the method with data from two of the most well-established PET radiotracers, (15)O-H(2)O and (18)F-fluorodeoxyglucose, used for assessment of blood perfusion and glucose metabolism respectively. The presentation illustrates the use of two open-source tools, AMIDE and R, for PET scan manipulation and model inference.
Small-sized microplastics and pigmented particles in bottled mineral water.
Oßmann, Barbara E; Sarau, George; Holtmannspötter, Heinrich; Pischetsrieder, Monika; Christiansen, Silke H; Dicke, Wilhelm
2018-09-15
Up to now, only a few studies about microparticle contamination of bottled mineral water have been published. The smallest analysed particle size was 5 μm. However, due to toxicological reasons, especially microparticles smaller than 1.5 μm are critically discussed. Therefore, in the present study, 32 samples of bottled mineral water were investigated for contamination by microplastics, pigment and additive particles. Due to the application of aluminium coated polycarbonate membrane filters and micro-Raman spectroscopy, a lowest analysed particle size of 1 μm was achieved. Microplastics were found in water from all bottle types: in single use and reusable bottles made of poly(ethylene terephthalate) (PET) as well as in glass bottles. The amount of microplastics in mineral water varied from 2649 ± 2857 per litre in single use PET bottles up to 6292 ± 10521 per litre in glass bottles. While in plastic bottles, the predominant polymer type was PET; in glass bottles various polymers such as polyethylene or styrene-butadiene-copolymer were found. Hence, besides the packaging itself, other contamination sources have to be considered. Pigment particles were detected in high amounts in reusable, paper labelled bottles (195047 ± 330810 pigment particles per litre in glass and 23594 ± 25518 pigment particles per litre in reusable paper labelled PET bottles). Pigment types found in water samples were the same as used for label printing, indicating the bottle cleaning process as possible contamination route. Furthermore, on average 708 ± 1024 particles per litre of the additive Tris(2,4-di-tert-butylphenyl)phosphite were found in reusable PET bottles. This additive might be leached out from the bottle material itself. Over 90% of the detected microplastics and pigment particles were smaller than 5 μm and thus not covered by previous studies. In summary, this is the first study reporting about microplastics, pigment and additive particles found in bottled mineral water samples with a smallest analysed particle size of 1 μm. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding Wanyu; Key Laboratory of Materials Modification by Laser, Ion and Electron Beams, Ministry of Education, Dalian University of Technology, Dalian 116024; Li Li
2013-03-14
The super-thin silicon oxynitride (SiO{sub x}N{sub y}) films were deposited onto the N doped polyethylene terephthalate (PET) surface. Varying the N doping parameters, the different chemical bond structures were obtained at the interface between the SiO{sub x}N{sub y} film and the PET surface. X-ray photoelectron spectra results showed that at the initial stage of SiO{sub x}N{sub y} film growth, the C=N bonds could be broken and C-N-Si crosslink bonds could be formed at the interface of SiO{sub x}N{sub y}/PET, which C=N bonds could be formed onto the PET surface during the N doping process. At these positions, the SiO{sub x}N{submore » y} film could be crosslinked well onto the PET surface. Meanwhile, the doped N could crosslink the [SiO{sub 4}] and [SiN{sub 4}] tetrahedrons, which could easily form the dense layer structure at the initial stage of SiO{sub x}N{sub y} film growth, instead of the ring and/or chain structures of [SiO{sub 4}] tetrahedrons crosslinked by O. Finally, from the point of applying SiO{sub x}N{sub y}/PET complex as the substrate, the present work reveals a simple way to crosslink them, as well as the crosslink model and physicochemical mechanism happened at the interface of complex.« less
Methods and applications of positron-based medical imaging
NASA Astrophysics Data System (ADS)
Herzog, H.
2007-02-01
Positron emission tomography (PET) is a diagnostic imaging method to examine metabolic functions and their disorders. Dedicated ring systems of scintillation detectors measure the 511 keV γ-radiation produced in the course of the positron emission from radiolabelled metabolically active molecules. A great number of radiopharmaceuticals labelled with 11C, 13N, 15O, or 18F positron emitters have been applied both for research and clinical purposes in neurology, cardiology and oncology. The recent success of PET with rapidly increasing installations is mainly based on the use of [ 18F]fluorodeoxyglucose (FDG) in oncology where it is most useful to localize primary tumours and their metastases.
Fleischmann, Daniel F; Unterrainer, Marcus; Bartenstein, Peter; Belka, Claus; Albert, Nathalie L; Niyazi, Maximilian
2017-04-01
Most high-grade gliomas (HGG) recur after initial multimodal therapy and re-irradiation (Re-RT) has been shown to be a valuable re-treatment option in selected patients. We evaluated the prognostic value of dynamic time-to-peak analysis and early static summation images in O-(2- 18 F-fluoroethyl)-l-tyrosine ( 18 F-FET) PET for patients treated with Re-RT ± concomitant bevacizumab. We retrospectively analyzed 72 patients suffering from recurrent HGG with 18 F-FET PET prior to Re-RT. PET analysis revealed the maximal tumor-to-background-ratio (TBR max ), the biological tumor volume, the number of PET-foci and pattern of time-activity-curves (TACs; increasing vs. decreasing). Furthermore, the novel PET parameters early TBR max (at 5-15 min post-injection) and minimal time-to-peak (TTP min ) were evaluated. Additional analysis was performed for gender, age, KPS, O6-methylguanine-DNA methyltransferase methylation status, isocitrate dehydrogenase 1 mutational status, WHO grade and concomitant bevacizumab therapy. The influence of PET and clinical parameters on post-recurrence survival (PRS) was investigated. Shorter TTP min was related to shorter PRS after Re-RT with 6 months for TTP min < 12.5 min, 7 months for TTP min 12.5-25 min and 11 months for TTP min >25 min (p = 0.027). TTP min had a significant impact on PRS both on univariate (p = 0.027; continuous) and multivariate analysis (p = 0.011; continuous). Other factors significantly related to PRS on multivariate analysis were increasing vs. decreasing TACs (p = 0.008) and Karnofsky Performance Score (p = 0.015; <70 vs. ≥70). Early TBR max as well as the other conventional PET parameters were not significantly related to PRS on univariate analysis. Dynamic 18 F-FET PET with TTP min provides a high prognostic value for recurrent HGG prior to Re-RT, whereas early TBR max does not. Dynamic 18 F-FET PET using TTP min might help to personalize Re-RT treatment regimens in future through voxelwise TTP min analysis for dose painting purposes and PET-guided dose escalation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herholz, K.; Pietrzyk, U.; Wienhard, K.
1989-09-01
In 20 patients with ischemic cerebrovascular disease, classic migraine, or angiomas, we compared paired dynamic positron emission tomographic measurements of regional cerebral blood flow using both ({sup 15}O)water and ({sup 18}F)fluoromethane as tracers. Cerebral blood flow was also determined according to the autoradiographic technique with a bolus injection of ({sup 15}O)water. There were reasonable overall correlations between dynamic ({sup 15}O)water and ({sup 18}F)fluoromethane values for cerebral blood flow (r = 0.82) and between dynamic and autoradiographic ({sup 15}O)water values for cerebral blood flow (r = 0.83). We found a close correspondence between abnormal pathologic findings and visually evaluated cerebral bloodmore » flow tomograms obtained with the two tracers. On average, dynamic ({sup 15}O)water cerebral blood flow was 6% lower than that measured with ({sup 18}F)fluoromethane. There also was a general trend toward a greater underestimation with ({sup 15}O)water in high-flow areas, particularly in hyperemic areas, probably due to incomplete first-pass extraction of ({sup 15}O)water. Underestimation was not detected in low-flow areas or in the cerebellum. Absolute cerebral blood flow values were less closely correlated between tracers and techniques than cerebral blood flow patterns. The variability of the relation between absolute flow values was probably caused by confounding effects of the variation in the circulatory delay time. The autoradiographic technique was most sensitive to this type error.« less
Dong, Baiyan; Jiang, Hongquan; Manolache, Sorin; Wong, Amy C Lee; Denes, Ferencz S
2007-06-19
A simple cold plasma technique was developed to functionalize the surfaces of polyamide (PA) and polyester (PET) for the grafting of polyethylene glycol (PEG) with the aim of reducing biofilm formation. The surfaces of PA and PET were treated with silicon tetrachloride (SiCl4) plasma, and PEG was grafted onto plasma-functionalized substrates (PA-PEG, PET-PEG). Different molecular weights of PEG and grafting times were tested to obtain optimal surface coverage by PEG as monitored by electron spectroscopy for chemical analysis (ESCA). The presence of a predominant C-O peak on the PEG-modified substrates indicated that the grafting was successful. Data from hydroxyl group derivatization and water contact angle measurement also indicated the presence of PEG after grafting. The PEG-grafted PA and PET under optimal conditions had similar chemical composition and hydrophilicity; however, different morphology changes were observed after grafting. Both PA-PEG and PET-PEG surfaces developed under optimal plasma conditions showed about 96% reduction in biofilm formation by Listeria monocytogenes compared with that of the corresponding unmodified substrates. This plasma functionalization method provided an efficient way to graft PEG onto PA and PET surfaces. Because of the high reactivity of Si-Cl species, this method could potentially be applied to other polymeric materials.
Properties of an ideal PET perfusion tracer: new PET tracer cases and data.
Maddahi, Jamshid
2012-02-01
An ideal positron emission tomography (PET) tracer should be highly extractable by the myocardium and able to provide high-resolution images, should enable quantification of absolute myocardial blood flow (MBF), should be compatible with both pharmacologically induced and exercise-induced stress imaging, and should not require an on-site cyclotron. The PET radionuclides nitrogen-13 ammonia and oxygen-15 water require an on-site cyclotron. Rubidium-82 may be available locally due to the generator source, but greater utilization is limited because of its relatively low myocardial extraction fraction, long positron range, and generator cost. Flurpiridaz F 18, a novel PET tracer in development, has a high-extraction fraction, short positron range, and relatively long half-life (as compared to currently available tracers), and may be produced at regional cyclotrons. Results of early clinical trials suggest that both pharmacologically and exercise-induced stress PET imaging protocols can be completed more rapidly and with lower patient radiation exposure than with single-photon emission computerized tomography (SPECT) tracers. As compared to SPECT images in the same patients, flurpiridaz F 18 PET images showed better defect contrast. Flurpiridaz F 18 is a potentially promising tracer for assessment of myocardial perfusion, measurement of absolute MBF, calculation of coronary flow reserves, and assessment of cardiac function at the peak of the stress response.
Detection of pathogenic Yersinia enterocolitica in pet Djungarian hamsters in Japan
KAMEYAMA, Mitsuhiro; YABATA, Junko; OBANE, Noriko; OTSUKA, Hitoshi; NOMURA, Yasuharu
2016-01-01
The prevalence of Yersinia enterocolitica (Y. enterocolitica) and Yersinia pseudotuberculosis was examined in 151 pet animals including 108 rodents, 39 rabbits and four sugar gliders from 13 pet stores in the Yamaguchi Prefecture, Japan. Y. enterocolitica serogroup O:3 biotype 3 negative for the Voges-Proskauer reaction (O:3/3 variant VP-) was isolated from five Djungarian hamsters (Phodopus sungorus) raised at the same pet store. These pathogenic Y. enterocolitica isolates carried the virulence genes, yadA, ail and virF, and were shown to be clonal by pulsed-field gel electrophoresis with NotI digestion. This is a first report of pathogenic Y. enterocolitica O:3/3 variant VP- in pet Djungarian hamsters in Japan. PMID:27396397
2011-04-21
... [ .... EEO PL"',lI.', Pl:>1S:. .. · nAG.',EEJ A€~f)EA~''''ETTlE RE::'f-o':'::l P,G'.H:JR;)S",lhPEt. ... ','.! Pf" g':-'" iI~~~ 2.- ~~. I.~r 0" S' l_t e I.l'l ~aM;: .I.,. ...
Shrestha, Stal; Singh, Prachi; Cortes-Salva, Michelle Y; Jenko, Kimberly J; Ikawa, Masamichi; Kim, Min-Jeong; Kobayashi, Masato; Morse, Cheryl L; Gladding, Robert L; Liow, Jeih-San; Zoghbi, Sami S; Fujita, Masahiro; Innis, Robert B; Pike, Victor W
2018-06-13
In our preceding paper (Part 1), we identified three 1,5-bis-diaryl-1,2,4-triazole-based compounds that merited evaluation as potential positron emission tomography (PET) radioligands for selectively imaging cyclooxygenase-1 (COX-1) in monkey and human brain, namely, 1,5-bis(4-methoxyphenyl)-3-(alkoxy)-1 H-1,2,4-triazoles bearing a 3-methoxy (PS1), a 3-(2,2,2-trifluoroethoxy) (PS13), or a 3-fluoromethoxy substituent (PS2). PS1 and PS13 were labeled from phenol precursors by O- 11 C-methylation with [ 11 C]iodomethane and PS2 by O- 18 F-fluoroalkylation with [ 2 H 2 , 18 F]fluorobromomethane. Here, we evaluated these PET radioligands in monkey. All three radioligands gave moderately high uptake in brain, although [ 2 H 2 , 18 F]PS2 also showed undesirable radioactivity uptake in skull. [ 11 C]PS13 was selected for further evaluation, mainly based on more favorable brain kinetics than [ 11 C]PS1. Pharmacological preblock experiments showed that about 55% of the radioactivity uptake in brain was specifically bound to COX-1. An index of enzyme density, V T , was well identified from serial brain scans and from the concentrations of parent radioligand in arterial plasma. In addition, V T values were stable within 80 min, suggesting that brain uptake was not contaminated by radiometabolites. [ 11 C]PS13 successfully images and quantifies COX-1 in monkey brain, and merits further investigation for imaging COX-1 in monkey models of neuroinflammation and in healthy human subjects.
NASA Astrophysics Data System (ADS)
Janek Strååt, Sara; Andreassen, Björn; Jonsson, Cathrine; Noz, Marilyn E.; Maguire, Gerald Q., Jr.; Näfstadius, Peder; Näslund, Ingemar; Schoenahl, Frederic; Brahme, Anders
2013-08-01
The purpose of this study was to investigate in vivo verification of radiation treatment with high energy photon beams using PET/CT to image the induced positron activity. The measurements of the positron activation induced in a preoperative rectal cancer patient and a prostate cancer patient following 50 MV photon treatments are presented. A total dose of 5 and 8 Gy, respectively, were delivered to the tumors. Imaging was performed with a 64-slice PET/CT scanner for 30 min, starting 7 min after the end of the treatment. The CT volume from the PET/CT and the treatment planning CT were coregistered by matching anatomical reference points in the patient. The treatment delivery was imaged in vivo based on the distribution of the induced positron emitters produced by photonuclear reactions in tissue mapped on to the associated dose distribution of the treatment plan. The results showed that spatial distribution of induced activity in both patients agreed well with the delivered beam portals of the treatment plans in the entrance subcutaneous fat regions but less so in blood and oxygen rich soft tissues. For the preoperative rectal cancer patient however, a 2 ± (0.5) cm misalignment was observed in the cranial-caudal direction of the patient between the induced activity distribution and treatment plan, indicating a beam patient setup error. No misalignment of this kind was seen in the prostate cancer patient. However, due to a fast patient setup error in the PET/CT scanner a slight mis-position of the patient in the PET/CT was observed in all three planes, resulting in a deformed activity distribution compared to the treatment plan. The present study indicates that the induced positron emitters by high energy photon beams can be measured quite accurately using PET imaging of subcutaneous fat to allow portal verification of the delivered treatment beams. Measurement of the induced activity in the patient 7 min after receiving 5 Gy involved count rates which were about 20 times lower than that of a patient undergoing standard 18F-FDG treatment. When using a combination of short lived nuclides such as 15O (half-life: 2 min) and 11C (half-life: 20 min) with low activity it is not optimal to use clinical reconstruction protocols. Thus, it might be desirable to further optimize reconstruction parameters as well as to address hardware improvements in realizing in vivo treatment verification with PET/CT in the future. A significant improvement with regard to 15O imaging could also be expected by having the PET/CT unit located close to the radiation treatment room.
Kiani, Amin; Ahmadloo, Mahsa; Shariatifar, Nabi; Moazzen, Mojtaba; Baghani, Abbas Norouzian; Khaniki, GholamReza Jahed; Taghinezhad, Ali; Kouhpayeh, Amin; Mousavi Khaneghah, Amin; Ghajarbeygi, Peyman
2018-05-01
In the current study, a novel magnetic solid phase extraction (MSPE) technique combined with a gas chromatography/mass spectroscopy (GC/MS) was developed to determine the phthalate ester content of bottled Doogh samples. Doogh is a yogurt-based drinking beverage, which is frequently consumed in Middle East and Balkans. It is produced by stirring yogurt in Chern separation machine and consists of substances such as water, yogurt, and salt in addition to aqueous extracts of native herbs. The magnetic multi-walled carbon nanotubes (MWCNT-Fe 3 O 4 ) were used as adsorbents of phthalate acid esters (PAEs) due to a superior adsorption capability of hydrophobic compounds. In this context, the quantity of the extractable migrated phthalate esters (dibutyl phthalate (DBP), dimethyl phthalate (DMP), butyl benzyl phthalate (BBP), diethyl phthalate (DEP), di-N-octyl phthalate (DNOP), and bis (2-ethylhexyl) phthalate (DEHP)) from polyethylene terephthalate (PET) bottles into Doogh samples was measured. The correlation between the concentration of migrated PAEs and some factors such as the type of Doogh (gaseous and without gas), difference in brand (five brands), volume (1500 and 300 mL), and the storage time also was investigated. The migration level into Doogh samples was increased by incorporating of gas as well as increasing the volume of PET bottles. Also, with elaborating of storage time, the migration of some phthalates such as DEHP (the mean from 2419.85 ng L -1 in the first week to 2716.15 ng L -1 in the second month), DEP, and total phthalate was increased. However, no significant difference in concentrations of migrated phthalate esters among different examined brands was noted. Finally, the concentration of migrated PAEs from bottle into all the examined Doogh samples was below the defined standards by EPA; 6 μg/L for DEHP in drinking water. Graphical abstract ᅟ.
NASA Astrophysics Data System (ADS)
Müller-Schauenburg, Wolfgang; Reimold, Matthias
Positron Emission Tomography is a well-established technique that allows imaging and quantification of tissue properties in-vivo. The goal of pharmacokinetic modelling is to estimate physiological parameters, e.g. perfusion or receptor density from the measured time course of a radiotracer. After a brief overview of clinical application of PET, we summarize the fundamentals of modelling: distribution volume, Fick's principle of local balancing, extraction and perfusion, and how to calculate equilibrium data from measurements after bolus injection. Three fundamental models are considered: (i) the 1-tissue compartment model, e.g. for regional cerebral blood flow (rCBF) with the short-lived tracer [15O]water, (ii) the 2-tissue compartment model accounting for trapping (one exponential + constant), e.g. for glucose metabolism with [18F]FDG, (iii) the reversible 2-tissue compartment model (two exponentials), e.g. for receptor binding. Arterial blood sampling is required for classical PET modelling, but can often be avoided by comparing regions with specific binding with so called reference regions with negligible specific uptake, e.g. in receptor imaging. To estimate the model parameters, non-linear least square fits are the standard. Various linearizations have been proposed for rapid parameter estimation, e.g. on a pixel-by-pixel basis, for the prize of a bias. Such linear approaches exist for all three models; e.g. the PATLAK-plot for trapping substances like FDG, and the LOGAN-plot to obtain distribution volumes for reversibly binding tracers. The description of receptor modelling is dedicated to the approaches of the subsequent lecture (chapter) of Millet, who works in the tradition of Delforge with multiple-injection investigations.
NASA Technical Reports Server (NTRS)
Gelfand, R.; Clark, J. M.; Lambertsen, C. J.; Pisarello, J. B.
1987-01-01
Prolonged exposures of men to continuous hyperoxia at 3.0, 2.5, 2.0, and 1.5 ATA were conducted to define CNS oxygen tolerance and to investigate the effects of prolonged hyperoxia on CNS and other organ functions. Altered respiratory homeostasis was evident during exposures of men to 2.5 and 3.0 ATA O2 as nonprogressive increment in ventilation and reciprocal decrement in PET(CO2). These changes were progressive during exposure at 1.5 ATA O2. Mean values of respiratory reactivity at CO2 were somewhat increased following prolonged hyperoxia at 1.5 and 2.5 ATA, compared to preexposure mean values. Hypoxic ventilatory response was unchanged or enhanced after oxygen exposures at 1.5 and 2.5 ATA. Observed respiratory and body temperature changes were not of sufficient magnitude to impair function.
NASA Astrophysics Data System (ADS)
Toner, J. D.; Catling, D. C.
2016-05-01
Perchlorate salts found on Mars are extremely hygroscopic and form low eutectic temperature aqueous solutions, which could allow liquid water to exist on Mars despite cold and dry conditions. The formation, dynamics, and potential habitability of perchlorate salt solutions can be broadly understood in terms of water activity. Water activity controls condensation and evaporation of water vapor in brines, deliquescence and efflorescence of crystalline salts, and ice formation during freezing. Furthermore, water activity is a basic parameter defining the habitability of aqueous solutions. Despite the importance of water activity, its value in perchlorate solutions has only been measured at 298.15 K and at the freezing point of water. To address this lack of data, we have determined water activities in NaClO4, Ca(ClO4)2, and Mg(ClO4)2 solutions using experimental heat capacities measured by Differential Scanning Calorimetry. Our results include concentrations up to near-saturation and temperatures ranging from 298.15 to 178 K. We find that water activities in NaClO4 solutions increase with decreasing temperature, by as much as 0.25 aw from 298.15 to 178 K. Consequently, aw reaches ∼0.6-0.7 even for concentrations up to 15 molal NaClO4 below 200 K. In contrast, water activities in Ca(ClO4)2 and Mg(ClO4)2 solutions generally decrease with decreasing temperature. The temperature dependence of water activity indicates that low-temperature NaClO4 solutions will evaporate and deliquesce at higher relative humidity, crystallize ice at higher temperature, and potentially be more habitable for life (at least in terms of water activity) compared to solutions at 298.15 K. The opposite effects occur in Ca(ClO4)2 and Mg(ClO4)2 solutions.
Toussaint, Marie; Vidal, Jean-Claude; Salmon, Jean-Michel
2014-04-02
The management of dissolved and headspace gases during bottling and the choice of packaging are both key factors for the shelf life of wine. Two kinds of 75 cL polyethylene terephthalate (PET) bottles (with or without recycled PET) were compared to glass bottles filled with a rosé wine, closed with the same screwcaps and stored upright at 20 °C in light or in the dark. Analytical monitoring (aphrometric pressure, headspace volume, O2, N2, CO2, and SO2) was carried out for 372 days. After the consumption of O2 trapped during bottling, the total O2 content in glass bottles remained stable. A substantial decrease of CO2 and SO2 concentration and an increase of O2 concentration were observed in the PET bottles after 6 months because of the considerable gas permeability of monolayer PET. Light accelerated O2 consumption during the early months. Finally, the kinetic monitoring of partial pressures in gas and liquid phases in bottles showed contrasting behavior of O2 and N2 in comparison with CO2.
Hirano, Yoshiyuki; Nitta, Munetaka; Nishikido, Fumihiko; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga
2016-07-07
The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2SiO5), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a (12)C beam with an energy of 290 MeV u(-1). Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible.
NASA Astrophysics Data System (ADS)
Hirano, Yoshiyuki; Nitta, Munetaka; Nishikido, Fumihiko; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga
2016-07-01
The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2SiO5), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a 12C beam with an energy of 290 MeV u-1. Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible.
Spangenberg, Jorge E
2012-11-30
The choice of containers for storage of aqueous samples between their collection, transport and water hydrogen ((2)H) and oxygen ((18)O) stable isotope analysis is a topic of concern for a wide range of fields in environmental, geological, biomedical, food, and forensic sciences. The transport and separation of water molecules during water vapor or liquid uptake by sorption or solution and the diffusive transport of water molecules through organic polymer material by permeation or pervaporation may entail an isotopic fractionation. An experiment was conducted to evaluate the extent of such fractionation. Sixteen bottle-like containers of eleven different organic polymers, including low and high density polyethylene (LDPE and HDPE), polypropylene (PP), polycarbonate (PC), polyethylene terephthalate (PET), and perfluoroalkoxy-Teflon (PFA), of different wall thickness and size were completely filled with the same mineral water and stored for 659 days under the same conditions of temperature and humidity. Particular care was exercised to keep the bottles tightly closed and prevent loss of water vapor through the seals. Changes of up to +5‰ for δ(2)H values and +2.0‰ for δ(18)O values were measured for water after more than 1 year of storage within a plastic container, with the magnitude of change depending mainly on the type of organic polymer, wall thickness, and container size. The most important variations were measured for the PET and PC bottles. Waters stored in glass bottles with Polyseal™ cone-lined PP screw caps and thick-walled HDPE or PFA containers with linerless screw caps having an integrally molded inner sealing ring preserved their original δ(2)H and δ(18)O values. The carbon, hydrogen, and oxygen stable isotope compositions of the organic polymeric materials were also determined. The results of this study clearly show that for precise and accurate measurements of the water stable isotope composition in aqueous solutions, rigorous sampling and storage procedures are needed both for laboratory standards and for unknown samples. Copyright © 2012 John Wiley & Sons, Ltd.
Kudomi, Nobuyuki; Maeda, Yukito; Yamamoto, Hiroyuki; Yamamoto, Yuka; Hatakeyama, Tetsuhiro; Nishiyama, Yoshihiro
2018-05-01
CBF, OEF, and CMRO 2 images can be quantitatively assessed using PET. Their image calculation requires arterial input functions, which require invasive procedure. The aim of the present study was to develop a non-invasive approach with image-derived input functions (IDIFs) using an image from an ultra-rapid O 2 and C 15 O 2 protocol. Our technique consists of using a formula to express the input using tissue curve with rate constants. For multiple tissue curves, the rate constants were estimated so as to minimize the differences of the inputs using the multiple tissue curves. The estimated rates were used to express the inputs and the mean of the estimated inputs was used as an IDIF. The method was tested in human subjects ( n = 24). The estimated IDIFs were well-reproduced against the measured ones. The difference in the calculated CBF, OEF, and CMRO 2 values by the two methods was small (<10%) against the invasive method, and the values showed tight correlations ( r = 0.97). The simulation showed errors associated with the assumed parameters were less than ∼10%. Our results demonstrate that IDIFs can be reconstructed from tissue curves, suggesting the possibility of using a non-invasive technique to assess CBF, OEF, and CMRO 2 .
NASA Astrophysics Data System (ADS)
Attanasi, F.; Knopf, A.; Parodi, K.; Paganetti, H.; Bortfeld, T.; Rosso, V.; Del Guerra, A.
2011-08-01
The interest in positron emission tomography (PET) as a tool for treatment verification in proton therapy has become widespread in recent years, and several research groups worldwide are currently investigating the clinical implementation. After the first off-line investigation with a PET/CT scanner at MGH (Boston, USA), attention is now focused on an in-room PET application immediately after treatment in order to also detect shorter-lived isotopes, such as O15 and N13, minimizing isotope washout and avoiding patient repositioning errors. Clinical trials are being conducted by means of commercially available PET systems, and other tests are planned using application-dedicated tomographs. Parallel to the experimental investigation and new hardware development, great interest has been shown in the development of fast procedures to provide feedback regarding the delivered dose from reconstructed PET images. Since the thresholds of inelastic nuclear reactions leading to tissue β+-activation fall within the energy range of 15-20 MeV, the distal activity fall-off is correlated, but not directly matched, to the distal fall-off of the dose distribution. Moreover, the physical interactions leading to β+-activation and energy deposition are of a different nature. All these facts make it essential to further develop accurate and fast methodologies capable of predicting, on the basis of the planned dose distribution, expected PET images to be compared with actual PET measurements, thus providing clinical feedback on the correctness of the dose delivery and of the irradiation field position. The aim of this study has been to validate an analytical model and to implement and evaluate it in a fast and flexible framework able to locally predict such activity distributions directly taking the reference planning CT and planned dose as inputs. The results achieved in this study for phantoms and clinical cases highlighted the potential of the implemented method to predict expected activity distributions with great accuracy. Thus, the analytical model can be used as a powerful substitute method to the sensitive and time-consuming Monte Carlo approach.
Development of a circular shape Si-PM-based detector ring for breast-dedicated PET system
NASA Astrophysics Data System (ADS)
Nakanishi, Kouhei; Yamamoto, Seiichi; Watabe, Hiroshi; Abe, Shinji; Fujita, Naotoshi; Kato, Katsuhiko
2018-02-01
In clinical situations, various breast-dedicated positron emission tomography (PET) systems have been used. However, clinical breast-dedicated PET systems have polygonal detector ring. Polygonal detector ring sometimes causes image artifact, so complicated reconstruction algorithm is needed to reduce artifact. Consequently, we developed a circular detector ring for breast-dedicated PET to obtain images without artifact using a simple reconstruction algorithm. We used Lu1.9Gd0.1SiO5 (LGSO) scintillator block which was made of 1.5 x 1.9 x 15 mm pixels that were arranged in an 8 x 24 matrix. As photodetectors, we used silicon photomultiplier (Si-PM) arrays whose channel size was 3 x 3 mm. A detector unit was composed of four scintillator blocks, 16 Si-PM arrays and a light guide. The developed detector unit had angled configuration since the light guide was bending. A detector unit had three gaps with an angle of 5.625° between scintillator blocks. With these configurations, we could arrange 64 scintillator blocks in nearly circular shape (regular 64-sided polygon) using 16 detector units. The use of the smaller number of detector units could reduce the size of the front-end electronics circuits. The inner diameter of the developed detector ring was 260 mm. This size was similar to those of brain PET systems, so our breast-dedicated PET detector ring can measure not only breast but also brain. Measured radial, tangential and axial spatial resolution of the detector ring reconstructed by the filtered back-projection (FBP) algorithm were 2.1 mm FWHM, 2.0 mm FWHM and 1.7 mm FWHM at center of field of view (FOV), respectively. The sensitivity was 2.0% at center of the axial FOV. With the developed detector ring, we could obtain high resolution image of the breast phantom and the brain phantom. We conclude that our developed Si-PM-based detector ring is promising for a high resolution breast-dedicated PET system that can also be used for brain PET system.
Micro-chip initiator realized by integrating Al/CuO multilayer nanothermite on polymeric membrane
NASA Astrophysics Data System (ADS)
Taton, G.; Lagrange, D.; Conedera, V.; Renaud, L.; Rossi, C.
2013-10-01
We have developed a new nanothermite based polymeric electro-thermal initiator for non-contact ignition of a propellant. A reactive Al/CuO multilayer nanothermite resides on a 100 µm thick SU-8/PET (polyethyleneterephtalate) membrane to insulate the reactive layer from the silicon bulk substrate. When current is supplied to the initiator, the chemical reaction Al+CuO occurs and sparkles are spread to a distance of several millimeters. A micro-manufacturing process for fabricating the initiator is presented and the electrical behaviors of the ignition elements are also investigated. The characteristics of the initiator made on a 100 µm thick SU-8/PET membrane were compared to two bulk electro-thermal initiators: one on a silicon and one on a Pyrex substrate. The PET devices give 100% of Al/CuO ignition success for an electrical current >250 mA. Glass based reactive initiators give 100% of Al/CuO ignition success for an electrical current >500 mA. Reactive initiators directly on silicon cannot initiate even with a 4 A current. At low currents (<1 A), the initiation time is two orders of magnitude longer for Pyrex initiator compared to those obtained for PET initiator technology. We also observed that, the Al/CuO thermite film on PET membrane reacts within 1 ms (sparkles duration) whereas it reacts within 4 ms on Pyrex. The thermite reaction is 40 times greater in intensity using the PET substrate in comparison to Pyrex.
Harris, Ashley D; Ide, Kojiro; Poulin, Marc J; Frayne, Richard
2006-02-15
Breath-by-breath variability of the end-tidal partial pressure of CO2 (Pet(CO2)) has been shown to be associated with cerebral blood flow (CBF) fluctuations. These fluctuations can impact neuroimaging techniques that depend on cerebrovascular blood flow. We hypothesized that controlling Pet(CO2) would reduce CBF variability. Dynamic end-tidal forcing was used to control Pet(CO2) at 1.5 mm Hg above the resting level and to hold the end-tidal partial pressure of oxygen (Pet(O2)) at the resting level. Peak blood velocity in the middle cerebral artery (MCA) was measured by transcranial Doppler ultrasound (TCD) as an index of CBF. Blood velocity parameters and timing features were determined on each waveform and the variance of these parameters was compared between Normal (air breathing) and Forcing (end-tidal gas control) sessions. The variability of all velocity parameters was significantly reduced in the Forcing session. In particular, the variability of the average velocity over the cardiac cycle was decreased by 18.2% (P < 0.001). For the most part, the variability of the timing parameters was unchanged. Thus, we conclude that controlling Pet(CO2) is effective in reducing CBF variability, which would have important implications for physiologic neuroimaging.
Law, Marilyn P; Wagner, Stefan; Kopka, Klaus; Pike, Victor W; Schober, Otmar; Schäfers, Michael
2008-01-01
Radioligand binding studies show that beta(1)-adrenoceptor (beta(1)-AR) density may be reduced in heart disease without down regulation of beta(2)-ARs. Radioligands are available for measuring total beta-AR density non-invasively with clinical positron emission tomography (PET) but none are selective for beta(1)- or beta(2)-ARs. The aim was to evaluate ICI 89,406, a beta(1)-AR-selective antagonist amenable to labelling with positron emitters, for PET. The S-enantiomer of an [O-methyl-(11)C] derivative of ICI 89,406 ((S)-[(11)C]ICI-OMe) was synthesised. Tissue radioactivity after i.v. injection of (S)-[(11)C]ICI-OMe (< 2 nmol x kg(-1)) into adult Wistar rats was assessed by small animal PET and post mortem dissection. Metabolism was assessed by HPLC of extracts prepared from plasma and tissues and by measuring [(11)C]CO(2) in exhaled air. The heart was visualised by PET after injection of (S)-[(11)C]ICI-OMe but neither unlabelled (S)-ICI-OMe nor propranolol (non-selective beta-AR antagonist) injected 15 min after (S)-[(11)C]ICI-OMe affected myocardial radioactivity. Ex vivo dissection showed that injecting unlabelled (S)-ICI-OMe, propranolol or CGP 20712A (beta(1)-selective AR antagonist) at high dose (> 2 mumol x kg(-1)) before (S)-[(11)C]ICI-OMe had a small effect on myocardial radioactivity. HPLC demonstrated that radioactivity in myocardium was due to unmetabolised (S)-[(11)C]ICI-OMe although (11)C-labelled metabolites rapidly appeared in plasma and liver and [(11)C]CO(2) was detected in exhaled air. Myocardial uptake of (S)-[(11)C]ICI-OMe after i.v. injection was low, possibly due to rapid metabolism in other tissues. Injection of unlabelled ligand or beta-AR antagonists had little effect indicating that binding was mainly to non-specific myocardial sites, thus precluding the use of (S)-[(11)C]ICI-OMe to assess beta(1)-ARs with PET.
Dugan, J.T.; Peckenpaugh, J.M.
1985-01-01
The Central Midwest aquifer system, in parts of Arkansas, Colorado, Kansas, Missouri, Nebraska, New Mexico, South Dakota, and Texas, is a region of great hydrologic diversity. This study examines the relationships between climate, vegetation, and soil that affect consumptive water use and recharge to the groundwater system. Computations of potential recharge and consumptive water use were restricted to those areas where the aquifers under consideration were the immediate underlying system. The principal method of analysis utilized a soil moisture computer model. This model requires four types of input: (1) hydrologic properties of the soils, (2) vegetation types, (3) monthly precipitation, and (4) computed monthly potential evapotranspiration (PET) values. The climatic factors that affect consumptive water use and recharge were extensively mapped for the study area. Nearly all the pertinent climatic elements confirmed the extreme diversity of the region. PET and those factors affecting it--solar radiation, temperature, and humidity--showed large regional differences; mean annual PET ranged from 36 to 70 inches in the study area. The seasonal climatic patterns indicate significant regional differences in those factors affecting seasonal consumptive water use and recharge. In the southern and western parts of the study area, consumptive water use occurred nearly the entire year; whereas, in northern parts it occurred primarily during the warm season (April through September). Results of the soil-moisture program, which added the effects of vegetation and the hydrologic characteristics of the soil to computed PET values, confirmed the significant regional differences in consumptive water use or actual evapotranspiration (AET) and potential groundwater recharge. Under two different vegetative conditions--the 1978 conditions and pre-agricultural conditions consisting of only grassland and woodland--overall differences in recharge were minimal. Mean annual recharge under both conditions averaged slightly more than 4.5 inches for the entire study area, but ranged from less than 0.10 inches in eastern Colorado to slightly more than 15 inches in Arkansas. (Lantz-PTT)
Rogers, Karyne M; Nicolini, Eric; Gauthier, Virginie
2012-09-01
Nitrate concentrations, water isotopes (δ(2)H and δ(18)O(water)) and associated nitrate isotopes (δ(15)N(nitrate) and δ(18)O(nitrate)) from 10 drinking water wells, 5 fresh water springs and the discharge from 3 wastewater treatment stations in Réunion Island, located in the Indian Ocean, were analysed. We used a multi isotopic approach to investigate the extent of nitrate contamination, nitrate formation altitude and source of nitrates in Réunion Island's principal aquifer. Water from these study sites contained between 0.1 and 85.3 mg/L nitrate. δ(15)N(nitrate) values between +6 and +14‰ suggested the main sources of contamination were animal and/or human waste, rather than inorganic (synthetic) fertilisers, infiltrating through the subsurface into the saturated zone, due to rainfall leaching of the unsaturated zone at various altitudes of precipitation. Based on δ(15)N(nitrate) values alone, it was not possible to distinguish between animal and human activities responsible for the contamination of each specific catchment. However, using a multi isotope approach (δ(18)O(water) and δ(15)N(nitrate)), it was possible to relate the average altitude of rainfall infiltration (δ(18)O(water)) associated with the nitrate contamination (δ(18)O(nitrate)). This relationship between land use, rainfall recharge altitude and isotopic composition (δ(15)N(nitrate) and δ(18)O(water)) discriminated between the influences of human waste at lower (below 600 m elevation) or animal derived contamination (at elevations between 600 and 1300 m). By further comparing the theoretical altitude of nitrate formation calculated by the δ(18)O(nitrate), it was possible to determine that only 5 out of 15 fresh water wells and springs followed the conservative nitrate formation mechanism of 2/3δ(18)O(water)+1/3δ(18)O(air), to give nitrate formation altitudes which corresponded to land use activities. Copyright © 2012 Elsevier B.V. All rights reserved.
Park-Holohan, So-Jin; Asselin, Marie-Claude; Turton, David R; Williams, Sharron L; Hume, Susan P; Camici, Paolo G; Rimoldi, Ornella E
2008-09-01
An increase in human cardiac alpha(1)-adrenoceptor (alpha(1)-AR) density is associated with various diseases such as myocardial ischemia, congestive heart failure, hypertrophic cardiomyopathy and hypertension. Positron emission tomography (PET) with an appropriate radioligand offers the possibility of imaging receptor function in the normal and diseased heart. [(11)C]GB67, an analogue of prazosin, has been shown in rats to have potential as a PET ligand with high selectivity to alpha(1)-AR. However, alpha(1)-AR density is up to ten times higher in rat heart compared to that in man. The aim of the present preclinical study was to extend the previous evaluation to a large mammal heart, where the alpha(1)-AR density is comparable to man, and to validate a method for quantification before PET studies in man. Seven [(11)C]GB67 PET studies, with weight-adjusted target dose of either 5.29 MBq kg(-1) (pilot, test-retest and baseline-predose studies) or 8.22 MBq kg(-1) (baseline-displacement studies), were performed in four anaesthetised pigs (39.5 +/- 3.9 kg). Total myocardial volume of distribution (V (T)) was estimated under different pharmacological conditions using compartmental analysis with a radiolabelled metabolite-corrected arterial plasma input function. A maximum possible blocking dose of 0.12 mumol kg(-1) of unlabeled GB67 was given 20 min before [(11)C]GB67 administration in the predose study and 45 min after administration of [(11)C]GB67 in the displacement study. In addition, [(15)O]CO (3,000 MBq) and [(15)O]H(2)O, with weight adjusted target dose of 10.57 MBq kg(-1), were also administered for estimation of blood volume recovery (RC) of the left ventricular cavity and myocardial perfusion (MBF), respectively. [(11)C]GB67 V (T) values (in ml cm(-3)) were estimated to be 24.2 +/- 5.5 (range, 17.3-31.3), 10.1 (predose) and 11.6 (displacement). MBF did not differ within each pig, including between baseline and predose conditions. Predose and displacement studies showed that specific binding of [(11)C]GB67 to myocardial alpha(1)-ARs accounts for approximately 50% of V (T). The present study offers a methodology for using [(11)C]GB67 as a radioligand to quantify human myocardial alpha(1)-ARs in clinical PET studies.
Electron-stimulated reactions in nanoscale water films adsorbed on α-Al 2 O 3 (0001)
Petrik, Nikolay G.; Kimmel, Greg A.
2018-04-11
The radiation-induced decomposition and desorption of nanoscale amorphous solid water (D 2O) films adsorbed on an α-Al 2O 3(0001) surface was studied at low temperature in ultrahigh vacuum using temperature programmed desorption (TPD) and electron stimulated desorption (ESD) with a mono-energetic, low energy electron source. ESD yields of molecular products (D 2, O 2 and D 2O) and the total sputtering yield increased with increasing D 2O coverage up to ~15 water monolayers (i.e. ~15 x 10 15 cm -2) to a coverage-independent level for thicker water films. Experiments with isotopically-layered water films (D 2O and H 2O) demonstrated thatmore » the highest water decomposition yields occurred at the interfaces of the nanoscale water films with the alumina substrate and vacuum. However, the increased reactivity of the water/alumina interface is relatively small compared to the enhancements in the non-thermal reactions previously observed at the water/Pt(111) and water/TiO 2(110) interfaces. Here, we propose that the relatively low activity of Al 2O 3(0001) for the radiation-induced production of molecular hydrogen is associated with lower reactivity of this surface with hydrogen atoms, which are likely precursors for the formation of molecular hydrogen.« less
Electron-stimulated reactions in nanoscale water films adsorbed on α-Al 2 O 3 (0001)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrik, Nikolay G.; Kimmel, Greg A.
The radiation-induced decomposition and desorption of nanoscale amorphous solid water (D 2O) films adsorbed on an α-Al 2O 3(0001) surface was studied at low temperature in ultrahigh vacuum using temperature programmed desorption (TPD) and electron stimulated desorption (ESD) with a mono-energetic, low energy electron source. ESD yields of molecular products (D 2, O 2 and D 2O) and the total sputtering yield increased with increasing D 2O coverage up to ~15 water monolayers (i.e. ~15 x 10 15 cm -2) to a coverage-independent level for thicker water films. Experiments with isotopically-layered water films (D 2O and H 2O) demonstrated thatmore » the highest water decomposition yields occurred at the interfaces of the nanoscale water films with the alumina substrate and vacuum. However, the increased reactivity of the water/alumina interface is relatively small compared to the enhancements in the non-thermal reactions previously observed at the water/Pt(111) and water/TiO 2(110) interfaces. Here, we propose that the relatively low activity of Al 2O 3(0001) for the radiation-induced production of molecular hydrogen is associated with lower reactivity of this surface with hydrogen atoms, which are likely precursors for the formation of molecular hydrogen.« less
Solar Disinfection of Viruses in Polyethylene Terephthalate Bottles
Carratalà, Anna; Dionisio Calado, Alex; Mattle, Michael J.; Meierhofer, Regula; Luzi, Samuel
2015-01-01
Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm2) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm2. Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation. PMID:26497451
Asiimwe, J K; Quilty, B; Muyanja, C K; McGuigan, K G
2013-12-01
Concerns about photodegradation products leaching from plastic bottle material into water during solar water disinfection (SODIS) are a major psychological barrier to increased uptake of SODIS. In this study, a comparison of SODIS efficacy using glass and plastic polyethylene terephalate (PET) bottles was carried out under strong real sunlight and overcast weather conditions at Makerere University in central Uganda. Both clear and turbid natural water samples from shallow wells and open dug wells, respectively, were used. Efficacy was determined from the inactivation of a wild strain of Escherichia coli in solar-exposed contaminated water in both glass and PET bottles. The studies reveal no significant difference in SODIS inactivation between glass and PET bottles (95% CI, p > 0.05), for all water samples under the different weather conditions except for clear water under overcast conditions where there was a small but significant difference (95% CI, p = 0.047) with less viable bacterial counts in PET bottles at two intermediate time points but not at the end of the exposure. The results demonstrate that SODIS efficacy in glass under tropical field conditions is comparable to PET plastic. SODIS users in these regions can choose either of reactors depending on availability and preference of the user.
Richard, JC; Pouzot, C; Gros, A; Tourevieille, C; Lebars, D; Lavenne, F; Frerichs, I; Guérin, C
2009-01-01
Introduction Electrical impedance tomography (EIT), which can assess regional lung ventilation at the bedside, has never been compared with positron-emission tomography (PET), a gold-standard to quantify regional ventilation. This experiment systematically compared both techniques in injured and non-injured lungs. Methods The study was performed in six mechanically ventilated female piglets. In normal lungs, tidal volume (VT) was randomly changed to 6, 8, 10 and 15 ml/kg on zero end-expiratory pressure (ZEEP), then, at VT 10 ml/kg, positive end-expiratory pressure (PEEP) was randomly changed to 5, 10 and 15 cmH2O. Afterwards, acute lung injury (ALI) was subsequently created in three animals by injecting 3 ml/kg hydrochloric acid into the trachea. Then at PEEP 5 cmH2O, VT was randomly changed to 8 and 12 ml/kg and PEEP of 10 and 15 cmH2O applied at VT 10 ml/kg. EIT and PET examinations were performed simultaneously. EIT ventilation (VTEIT) and lung volume (VL) were measured in the anterior and posterior area of each lung. On the same regions of interest, ventilation (VPET) and aerated lung volume (VAatten) were determined with PET. Results On ZEEP, VTEIT and VPET significantly correlated for global (VTEIT = VPET - 2E-13, R2 = 0.95, P < 0.001) and regional (VTEIT = 0.81VPET+7.65, R2 = 0.63, P < 0.001) ventilation over both conditions. For ALI condition, corresponding R2 were 0.91 and 0.73 (P < 0.01). Bias was = 0 and limits of agreement were -37.42 and +37.42 ml/min for global ventilation over both conditions. These values were 0.04 and -29.01 and +29.08 ml/min, respectively, for regional ventilation. Significant correlations were also found between VL and VAatten for global (VL = VAatten+1E-12, R2 = 0.93, P < 0.0001) and regional (VL = 0.99VAatten+0.92, R2 = 0.65, P < 0.001) volume. For ALI condition, corresponding R2 were 0.94 (P < 0.001) and 0.54 (P < 0.05). Bias was = 0 and limits of agreement ranged -38.16 and +38.16 ml for global ventilation over both conditions. These values were -0.24 and -31.96 to +31.48 ml, respectively, for regional ventilation. Conclusions Regional lung ventilation and volume were accurately measured with EIT in healthy and injured lungs and validated by simultaneous PET imaging. PMID:19480694
Qiao, Fei; Lei, Kun; Li, Zicheng; Liu, Qing; Wei, Zhanliang; An, Lihui; Qi, Hongli; Cui, Song
2018-01-01
Antimony (Sb) concentrations were measured in 10 brands of PET bottled drinking water available in supermarkets in China. To simulate general storage habits based on market research, these PET bottles with drinking water were stored for 4 weeks in a lab or a car trunk during the summer. Although the PET package material of brand A had the lowest Sb level (142.71 ± 29.81 μg/g), it showed a significant increase in Sb concentrations when stored in both the car trunk and the lab. There was significant release of Sb from the PET bottles into the water following 24 h of incubation at ≥ 40 °C (40, 50, 60, and 70 °C), especially at 70 °C. The potential health risk of Sb release from PET bottles was calculated based on daily intake values and determined to be acceptable for consumers under normal storage conditions.
Effect of TiO, nanoparticles on the interface in the PET-rubber composites.
Vladuta, Cristina; Andronic, Luminita; Duta, Anca
2010-04-01
Usually, ceramic powders (SiO2, ZnO) are used as fillers for enhancing rubber mechanical strength. Poly-ethylene terephthalate (PET)-rubber nanocomposites were prepared by compression molding using titanium oxide (TiO2) nanoparticles as low content fillers (<2% wt). The interface properties of PET-rubber nanocomposites were studied before and after keeping the samples under UV-radiation for a week. UV-radiation has interesting potential for the photochemical modification of polymers and TiO2. The influence of UV radiation on the properties of the interface polymer-TiO2 nanoparticles was evaluated. The impact of nanoparticle aggregates on the nanometer to micrometer organization of PET-rubber composites was studied with Atomic Force Microscopy (AFM). The interface properties were explained by measuring the contact angles and surface tensions. The interactions between components of nanocomposites were investigated with Fourier Transform-Infrared (FTIR) and the effects of TiO2 nanoparticle on the interfaces and composites crystalline structure were evaluated by X-ray diffraction (XRD). The results proved that the TiO2 nanoparticles, in different weight percentages, did not alter the nanocomposites crystallinity or the average crystallites size, but improve the interface properties.
NASA Astrophysics Data System (ADS)
Li, Lingwei; Chen, Yuanqing; Yin, Xiaoru; Song, Yang; Li, Na; Niu, Jinfen; Wu, Huimin; Qu, Wenwen
2017-12-01
We demonstrate a low-cost and facile photochemical solution method to prepare the ZrO2 resistive switching arrays as memristive units on flexible PET/ITO substrates. ZrO2 solution sensitive to UV light of 337 nm was synthesized using zirconium n-butyl alcohol as the precursor, and benzoylacetone as the complexing agent. After the dip-coated ZrO2 gel films were irradiated through a mask under the UV lamp (with wavelength of 325-365 nm) at room temperature and rinsed in ethanol, the ZrO2 gel arrays were obtained on PET/ITO substrates. Subsequently, the ZrO2 gel arrays were irradiated by deep UV light of 254 and 185 nm at 150 °C, resulting in the amorphous ZrO2 memristive micro-arrays. The ZrO2 units on flexible PET/ITO substrates exhibited excellent memristive properties. A high ratio of 104 of on-state and off-state resistance was obtained. The resistive switching behavior of the flexible device remained stable after being bent for 103 times. The device showed stable flexibility up to a minimum bending diameter of 1.25 cm.
Bhalla, Rajiv; Levason, William; Luthra, Sajinder K; McRobbie, Graeme; Sanderson, George; Reid, Gillian
2015-03-16
As part of a study to investigate the factors influencing the development of new, more effective metal-complex-based positron emission tomography (PET) imaging agents, the distorted octahedral complex, [GaCl(L)]⋅2 H2O has been prepared by reaction of 1-benzyl-1,4,7-triazacyclononane-4,7-dicarboxylic acid hydrochloride (H2L⋅HCl) with Ga(NO3)3⋅9 H2O, which is a convenient source of Ga(III) for reactions in water. Spectroscopic and crystallographic data for [GaCl(L)]⋅2 H2O are described, together with the crystal structure of [GaCl(L)]⋅MeCN. Fluorination of this complex by Cl(-)/F(-) exchange was achieved in high yield by treatment with KF in water at room temperature over 90 minutes, although the reaction was complete in approximately 30 minutes if heated to 80 °C, giving [GaF(L)]⋅2 H2O in good yield. The same complex was obtained by hydrothermal synthesis from GaF3⋅3 H2O and Li2L, and has been characterised by single-crystal X-ray analysis, IR, (1)H and (19)F{(1)H} NMR spectroscopy and ESI(+) MS. Radiofluorination of the pre-formed [GaCl(L)]⋅2 H2O has been demonstrated on a 210 nanomolar scale in aqueous NaOAc at pH 4 by using carrier-free (18)F(-), leading to 60-70% (18)F-incorporation after heating to 80 °C for 30 minutes. The resulting radioproduct was purified easily by using a solid-phase extraction (SPE) cartridge, leading to 98-99% radiochemical purity. The [Ga(18)F(L)] is stable for at least 90 minutes in 10% EtOH/NaOAc solution at pH 6, but defluorinates over this time scale at pH of approximately 7.5 in phosphate buffered saline (PBS) or human serum albumin (HSA). The subtle role of the Group 13 metal ion and co-ligand donor set in influencing the pH dependence of this system is discussed in the context of developing potential new imaging agents for PET. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bhalla, Rajiv; Levason, William; Luthra, Sajinder K; McRobbie, Graeme; Sanderson, George; Reid, Gillian
2015-01-01
As part of a study to investigate the factors influencing the development of new, more effective metal-complex-based positron emission tomography (PET) imaging agents, the distorted octahedral complex, [GaCl(L)]⋅2 H2O has been prepared by reaction of 1-benzyl-1,4,7-triazacyclononane-4,7-dicarboxylic acid hydrochloride (H2L⋅HCl) with Ga(NO3)3⋅9 H2O, which is a convenient source of GaIII for reactions in water. Spectroscopic and crystallographic data for [GaCl(L)]⋅2 H2O are described, together with the crystal structure of [GaCl(L)]⋅MeCN. Fluorination of this complex by Cl−/F− exchange was achieved in high yield by treatment with KF in water at room temperature over 90 minutes, although the reaction was complete in approximately 30 minutes if heated to 80 °C, giving [GaF(L)]⋅2 H2O in good yield. The same complex was obtained by hydrothermal synthesis from GaF3⋅3 H2O and Li2L, and has been characterised by single-crystal X-ray analysis, IR, 1H and 19F{1H} NMR spectroscopy and ESI+ MS. Radiofluorination of the pre-formed [GaCl(L)]⋅2 H2O has been demonstrated on a 210 nanomolar scale in aqueous NaOAc at pH 4 by using carrier-free 18F−, leading to 60–70 % 18F-incorporation after heating to 80 °C for 30 minutes. The resulting radioproduct was purified easily by using a solid-phase extraction (SPE) cartridge, leading to 98–99 % radiochemical purity. The [Ga18F(L)] is stable for at least 90 minutes in 10 % EtOH/NaOAc solution at pH 6, but defluorinates over this time scale at pH of approximately 7.5 in phosphate buffered saline (PBS) or human serum albumin (HSA). The subtle role of the Group 13 metal ion and co-ligand donor set in influencing the pH dependence of this system is discussed in the context of developing potential new imaging agents for PET. PMID:25652736
Jeganathan, Jeganaesan; Bassi, Amarjeet; Nakhla, George
2006-09-01
Wastewaters generating from pet food industries contain high concentration of oil and grease (O&G), which is difficult to treat through conventional biological treatment systems. In this study, the hydrolysis of O&G originating from pet food industrial wastewater was evaluated. Candida rugosa lipase was immobilized in calcium alginate beads and applied in the hydrolysis experiment. Results showed that approximately 50% of the O&G was hydrolyzed due to the enzyme activity. A significant increment in COD and VFA production was also observed. The immobilized lipase activity was confirmed with p-nitrophenyl palmitate (pNPP) before and after O&G hydrolysis. During the 3-day experiment, approximately 65% of the beads were recovered and after the hydrolysis, approximately 70% of the enzyme activity remained in the beads. This study shows the potential of immobilized lipase as a pre-treatment step in biological treatment of pet food manufacturing wastewater.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pankow, J. W.; Glick, S. H.
2006-05-01
Flexible polymer substrates coated with inorganic oxide moisture barriers are a potential replacement for glass backsheets in thin-film PV (photovoltaic) modules. Silicon oxynitride (SiO{sub x}N{sub y}) deposited by plasma enhanced chemical vapor deposition (PECVD) on polyethylene terephthalate (PET) represents one potential new backsheet candidate. Barrier deposition runs at NREL have included a nitrogen-rich plasma pretreatment prior to barrier deposition with the intention of cleaning the PET surface and enhancing adhesion of the SiO{sub x}N{sub y} barrier film to PET; however, test coupons of PET/barrier/EVA/TPE failed after damp-heat exposure. (EVA is ethylene vinyl acetate and TPE is Tedlar{reg_sign}-PET-EVA). PET substrates exposedmore » to plasma conditions similar to those used in pretreatment were examined by X-ray photoelectron spectroscopy (XPS) to reveal that new low molecular weight PET fragments were created at the PET surface. These fragments are responsible for barrier/PET interfacial failure and barrier transfer to the EVA encapsulant side following damp heat exposure.« less
Deep brain stimulation of nucleus accumbens region in alcoholism affects reward processing.
Heldmann, Marcus; Berding, Georg; Voges, Jürgen; Bogerts, Bernhard; Galazky, Imke; Müller, Ulf; Baillot, Gunther; Heinze, Hans-Jochen; Münte, Thomas F
2012-01-01
The influence of bilateral deep brain stimulation (DBS) of the nucleus nucleus (NAcc) on the processing of reward in a gambling paradigm was investigated using H(2)[(15)O]-PET (positron emission tomography) in a 38-year-old man treated for severe alcohol addiction. Behavioral data analysis revealed a less risky, more careful choice behavior under active DBS compared to DBS switched off. PET showed win- and loss-related activations in the paracingulate cortex, temporal poles, precuneus and hippocampus under active DBS, brain areas that have been implicated in action monitoring and behavioral control. Except for the temporal pole these activations were not seen when DBS was deactivated. These findings suggest that DBS of the NAcc may act partially by improving behavioral control.
Smith, Donald F; Dyve, Suzan; Minuzzi, Luciano; Jakobsen, Steen; Munk, Ole L; Marthi, Katalin; Cumming, Paul
2006-06-15
We have developed [(11)C]mirtazapine as a ligand for PET studies of antidepressant binding in living brain. However, previous studies have determined neither optimal methods for quantification of [(11)C]mirtazapine binding nor the pharmacological identity of this binding. To obtain that information, we have now mapped the distribution volume (V(d)) of [(11)C]mirtazapine relative to the arterial input in the brain of three pigs, in a baseline condition and after pretreatment with excess cold mirtazapine (3 mg/kg). Baseline V(d) ranged from 6 ml/ml in cerebellum to 18 ml/ml in frontal cortex, with some evidence for a small self-displaceable binding component in the cerebellum. Regional binding potentials (pBs) obtained by a constrained two-compartment model, using the V(d) observation in cerebellum, were consistently higher than pBs obtained by other arterial input or reference tissue methods. We found that adequate quantification of pB was obtained using the simplified reference tissue method. Concomitant PET studies with [(15)O]-water indicated that mirtazapine challenge increased CBF uniformly in cerebellum and other brain regions, supporting the use of this reference tissue for calculation of [(11)C]mirtazapine pB. Displacement by mirtazapine was complete in the cerebral cortex, but only 50% in diencephalon, suggesting the presence of multiple binding sites of differing affinities in that tissue. Competition studies with yohimbine and RX 821002 showed decreases in [(11)C]mirtazapine pB throughout the forebrain; use of the multireceptor version of the Michaelis-Menten equation indicated that 42% of [(11)C]mirtazapine binding in cortical regions is displaceable by yohimbine. Thus, PET studies confirm that [(11)C]mirtazapine affects alpha(2)-adrenoceptor binding sites in living brain. (c) 2006 Wiley-Liss, Inc.
Wong, David M; Alcott, Cody J; Wang, Chong; Bornkamp, Jennifer L; Young, Jessica L; Sponseller, Brett A
2011-11-15
To determine agreement between indirect measurements of end-tidal partial pressure of carbon dioxide (PetCO(2)) and saturation of hemoglobin with oxygen as measured by pulse oximetry (SpO(2)) with direct measurements of PaCO(2) and calculated saturation of hemoglobin with oxygen in arterial blood (SaO(2)) in conscious healthy and ill foals. Validation study. 10 healthy and 21 ill neonatal foals. Arterial blood gas analysis was performed on healthy and ill foals examined at a veterinary teaching hospital to determine direct measurements of PaCO(2) and PaO(2) along with SaO(2). Concurrently, PetCO(2) was measured with a capnograph inserted into a naris, and SpO(2) was measured with a reflectance probe placed at the base of the tail. Paired values were compared by use of Pearson correlation coefficients, and level of agreement was assessed with the Bland-Altman method. Mean ± SD difference between PaCO(2) and PetCO(2) was 0.1 ± 5.0 mm Hg. There was significant strong correlation (r = 0.779) and good agreement between PaCO(2) and PetCO(2). Mean ± SD difference between SaO(2) and SpO(2) was 2.5 ± 3.5%. There was significant moderate correlation (r = 0.499) and acceptable agreement between SaO(2) and SpO(2). Both PetCO(2) obtained by use of nasal capnography and SpO(2) obtained with a reflectance probe are clinically applicable and accurate indirect methods of estimating and monitoring PaCO(2) and SaO(2) in neonatal foals. Indirect methods should not replace periodic direct measurement of corresponding parameters.
Influence of Elevated Temperatures on Pet-Concrete Properties
NASA Astrophysics Data System (ADS)
Albano, C.; Camacho, N.; Hernández, M.; Matheus, A.; Gutiérrez, A.
2008-08-01
Lightweight aggregate is an important material in reducing the unit weight of concrete complying with special concrete structures of large high-rise buildings. Besides, the use of recycled PET bottles as lightweight aggregate in concrete is an effective contribution for environment preservation. So, the objective of the present work was to study experimentally the flexural strength of the PET -concrete blends and the thermal degradation of the PET in the concrete, when the blends with 10 and 20% in volume of PET were exposed to different temperatures (200, 400, 600 °C). The flexural strength of concrete-PET exposed to a heat source is strongly dependent on the temperature, water/cement ratio, as well as the content and particle size of PET. However, the activation energy is affected by the temperature, location of the PET particles on the slabs and the water/cement ratio. Higher water content originates thermal and hydrolytic degradation on the PET, while on the concrete, a higher vapor pressure which causes an increase in crack formation. The values of the activation energy are higher on the center of the slabs than on the surface, since concrete is a poor heat conductor.
NASA Astrophysics Data System (ADS)
Parodi, Katia; Bortfeld, Thomas; Enghardt, Wolfgang; Fiedler, Fine; Knopf, Antje; Paganetti, Harald; Pawelke, Jörg; Shakirin, Georgy; Shih, Helen
2008-06-01
Ion beams offer the possibility of improved conformation of the dose delivered to the tumor with better sparing of surrounding tissue and critical structures in comparison to conventional photon and electron external radiation treatment modalities. Full clinical exploitation of this advantage can benefit from in vivo confirmation of the actual beam delivery and, in particular, of the ion range in the patient. During irradiation, positron emitters like 15O (half-life T1/2≈2 min) and 11C ( T1/2≈20 min) are formed in nuclear interactions between the ions and the tissue. Detection of this transient radioactivity via positron emission tomography (PET) and comparison with the expectation based on the prescribed beam application may serve as an in vivo, non-invasive range validation method of the whole treatment planning and delivery chain. For technical implementation, PET imaging during irradiation (in-beam) requires the development of customized, limited angle detectors with data acquisition synchronized with the beam delivery. Alternatively, commercial PET or PET/CT scanners in close proximity to the treatment site enable detection of the residual activation from long-lived emitters shortly after treatment (offline). This paper reviews two clinical examples using a dedicated in-beam PET scanner for verification of carbon ion therapy at GSI Darmstadt, Germany, as well as a commercial offline PET/CT tomograph for post-radiation imaging of proton treatments at Massachusetts General Hospital, Boston, USA. Challenges as well as pros and cons of the two imaging approaches in dependence of the different ion type and beam delivery system are discussed.
Sethi, A; Rusu, I; Surucu, M; Halama, J
2012-06-01
Evaluate accuracy of multi-modality image registration in radiotherapy planning process. A water-filled anthropomorphic head phantom containing eight 'donut-shaped' fiducial markers (3 internal + 5 external) was selected for this study. Seven image sets (3CTs, 3MRs and PET) of phantom were acquired and fused in a commercial treatment planning system. First, a narrow slice (0.75mm) baseline CT scan was acquired (CT1). Subsequently, the phantom was re-scanned with a coarse slice width = 1.5mm (CT2) and after subjecting phantom to rotation/displacement (CT3). Next, the phantom was scanned in a 1.5 Tesla MR scanner and three MR image sets (axial T1, axial T2, coronal T1) were acquired at 2mm slice width. Finally, the phantom and center of fiducials were doped with 18F and a PET scan was performed with 2mm cubic voxels. All image scans (CT/MR/PET) were fused to the baseline (CT1) data using automated mutual-information based fusion algorithm. Difference between centroids of fiducial markers in various image modalities was used to assess image registration accuracy. CT/CT image registration was superior to CT/MR and CT/PET: average CT/CT fusion error was found to be 0.64 ± 0.14 mm. Corresponding values for CT/MR and CT/PET fusion were 1.33 ± 0.71mm and 1.11 ± 0.37mm. Internal markers near the center of phantom fused better than external markers placed on the phantom surface. This was particularly true for the CT/MR and CT/PET. The inferior quality of external marker fusion indicates possible distortion effects toward the edges of MR image. Peripheral targets in the PET scan may be subject to parallax error caused by depth of interaction of photons in detectors. Current widespread use of multimodality imaging in radiotherapy planning calls for periodic quality assurance of image registration process. Such studies may help improve safety and accuracy in treatment planning. © 2012 American Association of Physicists in Medicine.
Characterizing proton-activated materials to develop PET-mediated proton range verification markers
NASA Astrophysics Data System (ADS)
Cho, Jongmin; Ibbott, Geoffrey S.; Kerr, Matthew D.; Amos, Richard A.; Stingo, Francesco C.; Marom, Edith M.; Truong, Mylene T.; Palacio, Diana M.; Betancourt, Sonia L.; Erasmus, Jeremy J.; DeGroot, Patricia M.; Carter, Brett W.; Gladish, Gregory W.; Sabloff, Bradley S.; Benveniste, Marcelo F.; Godoy, Myrna C.; Patil, Shekhar; Sorensen, James; Mawlawi, Osama R.
2016-06-01
Conventional proton beam range verification using positron emission tomography (PET) relies on tissue activation alone and therefore requires particle therapy PET whose installation can represent a large financial burden for many centers. Previously, we showed the feasibility of developing patient implantable markers using high proton cross-section materials (18O, Cu, and 68Zn) for in vivo proton range verification using conventional PET scanners. In this technical note, we characterize those materials to test their usability in more clinically relevant conditions. Two phantoms made of low-density balsa wood (~0.1 g cm-3) and beef (~1.0 g cm-3) were embedded with Cu or 68Zn foils of several volumes (10-50 mm3). The metal foils were positioned at several depths in the dose fall-off region, which had been determined from our previous study. The phantoms were then irradiated with different proton doses (1-5 Gy). After irradiation, the phantoms with the embedded foils were moved to a diagnostic PET scanner and imaged. The acquired data were reconstructed with 20-40 min of scan time using various delay times (30-150 min) to determine the maximum contrast-to-noise ratio. The resultant PET/computed tomography (CT) fusion images of the activated foils were then examined and the foils’ PET signal strength/visibility was scored on a 5 point scale by 13 radiologists experienced in nuclear medicine. For both phantoms, the visibility of activated foils increased in proportion to the foil volume, dose, and PET scan time. A linear model was constructed with visibility scores as the response variable and all other factors (marker material, phantom material, dose, and PET scan time) as covariates. Using the linear model, volumes of foils that provided adequate visibility (score 3) were determined for each dose and PET scan time. The foil volumes that were determined will be used as a guideline in developing practical implantable markers.
NASA Astrophysics Data System (ADS)
Ahmadi, Eltefat; Fauzi, Ahmad; Hussin, Hashim; Baharun, Norlia; Ariffin, Kamar Shah; Rezan, Sheikh Abdul
2017-04-01
An innovative and sustainable carbothermal reduction and nitridation (CTRN) process of ilmenite (FeTiO3) using a mixture of polyethylene terephthalate (PET) and coal as the primary reductant under an H2-N2 atmosphere was proposed. The use of PET as an alternative source of carbon not only enhances the porosity of the pellets but also results in the separation of Fe from titanium oxycarbonitride (TiO x C y N z ) particles because of the differences in surface tension. The experiments were carried out at 1250°C for 3 h using four different PET contents ranging from 25wt% to 100wt% in the reductant. X-ray diffraction (XRD), scanning electron microscopy (SEM) in conjunction with energy-dispersive X-ray spectroscopy (EDX), and LECO elemental analysis were used to study the phases and microstructures of the reduced samples. In the case of 75wt% PET, iron distinctly separated from the synthesized TiO x C y N z phase. With increasing PET content in the sample, the reduction and nitridation rates substantially increased. The synthesis of an oxycarbonitride with stoichiometry of TiO0.02C0.13N0.85 with minimal intermediate titanium sub-oxides was achieved. The results also showed that the iron particles formed from CTRN of FeTiO3 exhibited a spherical morphology, which is conducive for Fe removal via the Becher process.
Effects of smoking marijuana on brain perfusion and cognition.
O'Leary, Daniel S; Block, Robert I; Koeppel, Julie A; Flaum, Michael; Schultz, Susan K; Andreasen, Nancy C; Ponto, Laura Boles; Watkins, G Leonard; Hurtig, Richard R; Hichwa, Richard D
2002-06-01
The effects of smoking marijuana on regional cerebral blood flow (rCBF) and cognitive performance were assessed in 12 recreational users in a double-blinded, placebo-controlled study. PET with [(15)Oxygen]-labeled water ([(15)O]H(2)O) was used to measure rCBF before and after smoking of marijuana and placebo cigarettes, as subjects repeatedly performed an auditory attention task. Smoking marijuana resulted in intoxication, as assessed by a behavioral rating scale, but did not significantly alter mean behavioral performance on the attention task. Heart rate and blood pressure increased dramatically following smoking of marijuana but not placebo cigarettes. However, mean global CBF did not change significantly. Increased rCBF was observed in orbital and mesial frontal lobes, insula, temporal poles, anterior cingulate, as well as in the cerebellum. The increases in rCBF in anterior brain regions were predominantly in "paralimbic" regions and may be related to marijuana's mood-related effects. Reduced rCBF was observed in temporal lobe auditory regions, in visual cortex, and in brain regions that may be part of an attentional network (parietal lobe, frontal lobe and thalamus). These rCBF decreases may be the neural basis of perceptual and cognitive alterations that occur with acute marijuana intoxication. There was no significant rCBF change in the nucleus accumbens or other reward-related brain regions, nor in basal ganglia or hippocampus, which have a high density of cannabinoid receptors.
De Boissezon, X; Marie, N; Castel-Lacanal, E; Marque, P; Bezy, C; Gros, H; Lotterie, J-A; Cardebat, D; Puel, M; Demonet, J-F
2009-12-01
It has long been a matter of debate whether recovery from aphasia after left perisylvian lesion is mediated by perilesional left hemispheric regions or by right homologous areas. To investigate the neural substrates of aphasia recovery, a longitudinal study in patients after a left single perisylvian stroke was performed. Thirteen aphasic patients were H2(15)O PET-scanned twice at a one year interval during a word generation task. Patients are divided into two groups according to language performance for the word generation task at PET2. For the Good Recovery (GR) group, patients' performances are indistinguishable from those of normal subjects, while patients from the Poor Recovery (PR) group keep language disorders. Using SPM2, Language-Rest contrast is computed for both groups at both PET stages. Then, Session Effect contrast (TEP2-TEP1>0) is calculated for both groups. For the GR group, the Session Effect contrast shows an increase of activations in the left Postero-Superior Temporal Gyrus PSTG but also in the right thalamus and lenticular nuclei; for PR patients, the right lenticular nucleus activation is more important at PET1 than PET2. The crucial role of the left temporal activation is confirmed and its increase is linked to behavioural recovery. The role of the right basal ganglia to support good recovery from aphasia is a new finding. Their activation may be more task-dependant and related to inhibition of the right frontal cortex.
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Verheijen, Remy B; Yaqub, Maqsood; Sawicki, Emilia; van Tellingen, Olaf; Lammertsma, Adriaan A; Nuijen, Bastiaan; Schellens, Jan H M; Beijnen, Jos H; Huitema, Alwin D R; Hendrikse, N Harry; Steeghs, Neeltje
2018-06-01
Transporters such as ABCB1 and ABCG2 limit the exposure of several anticancer drugs to the brain, leading to suboptimal treatment in the central nervous system. The purpose of this study was to investigate the effects of the ABCB1 and ABCG2 inhibitor elacridar on brain uptake using 11 C-erlotinib PET. Methods: Elacridar and cold erlotinib were administered orally to wild-type (WT) and Abcb1a/b;Abcg2 knockout mice. In addition, brain uptake was measured using 11 C-erlotinib imaging and ex vivo scintillation counting in knockout and WT mice. Six patients with advanced solid tumors underwent 11 C-erlotinib PET scans before and after a 1,000-mg dose of elacridar. 11 C-erlotinib brain uptake was quantified by pharmacokinetic modeling using volume of distribution (V T ) as the outcome parameter. In addition, 15 O-H 2 O scans to measure cerebral blood flow were acquired before each 11 C-erlotinib scan. Results: Brain uptake of 11 C-erlotinib was 2.6-fold higher in Abcb1a/b;Abcg2 knockout mice than in WT mice, measured as percentage injected dose per gram of tissue ( P = 0.01). In WT mice, the addition of elacridar (at systemic plasma concentrations of ≥200 ng/mL) resulted in an increased brain concentration of erlotinib, without affecting erlotinib plasma concentration. In patients, the V T of 11 C-erlotinib did not increase after intake of elacridar (0.213 ± 0.12 vs. 0.205 ± 0.07, P = 0.91). 15 O-H 2 O PET showed no significant changes in cerebral blood flow. Elacridar exposure in patients was 401 ± 154 ng/mL. No increase in V T with increased elacridar plasma exposure was found over the 271-619 ng/mL range. Conclusion: When Abcb1 and Abcg2 were disrupted in mice, brain uptake of 11 C-erlotinib increased both at a tracer dose and at a pharmacologic dose. In patients, brain uptake of 11 C-erlotinib was not higher after administration of elacridar. The more pronounced role that ABCG2 appears to play at the human blood-brain barrier and the lower potency of elacridar to inhibit ABCG2 may be an explanation of these interspecies differences. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
Human PET studies of metabotropic glutamate receptor subtype 5 with 11C-ABP688.
Ametamey, Simon M; Treyer, Valerie; Streffer, Johannes; Wyss, Matthias T; Schmidt, Mark; Blagoev, Milen; Hintermann, Samuel; Auberson, Yves; Gasparini, Fabrizio; Fischer, Uta C; Buck, Alfred
2007-02-01
3-(6-Methyl-pyridin-2-ylethynyl)-cyclohex-2-enone-O-11C-methyl-oxime (11C-ABP688), a noncompetitive and highly selective antagonist for the metabotropic glutamate receptor subtype 5 (mGluR5), was evaluated for its potential as a PET agent. Six healthy male volunteers (mean age, 25 y; range, 21-33 y) were studied. Brain perfusion (15O-H2O) was measured immediately before each 11C-ABP688 PET scan. For anatomic coregistration, T1-weighted MRI was performed on each subject. Arterial blood samples for the determination of the arterial input curve were obtained at predefined time points, and 11C-ABP688 uptake was assessed quantitatively using a 2-tissue-compartment model. An initial rapid uptake of radioactivity followed by a gradual clearance from all examined brain regions was observed. Relatively high radioactivity concentrations were observed in mGluR5-rich brain regions such as the anterior cingulate, medial temporal lobe, amygdala, caudate, and putamen, whereas radioactivity uptake in the cerebellum and white matter, regions known to contain low densities of mGluR5, was low. Specific distribution volume as an outcome measure of mGluR5 density in the various brain regions ranged from 5.45 +/- 1.47 (anterior cingulate) to 1.91 +/- 0.32 (cerebellum), and the rank order of the corresponding specific distribution volumes of 11C-ABP688 in cortical regions was temporal > frontal > occipital > parietal. The metabolism of 11C-ABP688 in plasma was rapid; at 60 min after injection, 25% +/- 0.03% of radioactivity measured in the plasma of healthy volunteers was intact parent compound. The results of these studies indicate that 11C-ABP688 has suitable characteristics and is a promising PET ligand for imaging mGluR5 distribution in humans. Furthermore, it could be of great value for the selection of appropriate doses of clinically relevant candidate drugs that bind to mGluR5 and for PET studies of patients with psychiatric and neurologic disorders.
Selecting Safe Pets (For Parents)
... kids to wash their hands with soap and water after handling pets. Don't keep undomesticated animals as house pets. Pet ownership has many benefits, and doing a little research before taking the plunge will help make your ...
Mayerhoefer, Marius E; Giraudo, Chiara; Senn, Daniela; Hartenbach, Markus; Weber, Michael; Rausch, Ivo; Kiesewetter, Barbara; Herold, Christian J; Hacker, Marcus; Pones, Matthias; Simonitsch-Klupp, Ingrid; Müllauer, Leonhard; Dolak, Werner; Lukas, Julius; Raderer, Markus
2016-02-01
To determine whether in patients with extranodal marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue lymphoma (MALT), delayed-time-point 2-F-fluoro-2-deoxy-d-glucose-positron emission tomography (F-FDG-PET) performs better than standard-time-point F-FDG-PET. Patients with untreated histologically verified MALT lymphoma, who were undergoing pretherapeutic F-FDG-PET/computed tomography (CT) and consecutive F-FDG-PET/magnetic resonance imaging (MRI), using a single F-FDG injection, in the course of a larger-scale prospective trial, were included. Region-based sensitivity and specificity, and patient-based sensitivity of the respective F-FDG-PET scans at time points 1 (45-60 minutes after tracer injection, TP1) and 2 (100-150 minutes after tracer injection, TP2), relative to the reference standard, were calculated. Lesion-to-liver and lesion-to-blood SUVmax (maximum standardized uptake values) ratios were also assessed. F-FDG-PET at TP1 was true positive in 15 o f 23 involved regions, and F-FDG-PET at TP2 was true-positive in 20 of 23 involved regions; no false-positive regions were noted. Accordingly, region-based sensitivities and specificities were 65.2% (confidence interval [CI], 45.73%-84.67%) and 100% (CI, 100%-100%) for F-FDG-PET at TP1; and 87.0% (CI, 73.26%-100%) and 100% (CI, 100%-100%) for F-FDG-PET at TP2, respectively. FDG-PET at TP1 detected lymphoma in at least one nodal or extranodal region in 7 of 13 patients, and F-FDG-PET at TP2 in 10 of 13 patients; accordingly, patient-based sensitivity was 53.8% (CI, 26.7%-80.9%) for F-FDG-PET at TP1, and 76.9% (CI, 54.0%-99.8%) for F-FDG-PET at TP2. Lesion-to-liver and lesion-to-blood maximum standardized uptake value ratios were significantly lower at TP1 (ratios, 1.05 ± 0.40 and 1.52 ± 0.62) than at TP2 (ratios, 1.67 ± 0.74 and 2.56 ± 1.10; P = 0.003 and P = 0.001). Delayed-time-point imaging may improve F-FDG-PET in MALT lymphoma.
Monte Carlo-based evaluation of S-values in mouse models for positron-emitting radionuclides
NASA Astrophysics Data System (ADS)
Xie, Tianwu; Zaidi, Habib
2013-01-01
In addition to being a powerful clinical tool, Positron emission tomography (PET) is also used in small laboratory animal research to visualize and track certain molecular processes associated with diseases such as cancer, heart disease and neurological disorders in living small animal models of disease. However, dosimetric characteristics in small animal PET imaging are usually overlooked, though the radiation dose may not be negligible. In this work, we constructed 17 mouse models of different body mass and size based on the realistic four-dimensional MOBY mouse model. Particle (photons, electrons and positrons) transport using the Monte Carlo method was performed to calculate the absorbed fractions and S-values for eight positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Y-86 and I-124). Among these radionuclides, O-15 emits positrons with high energy and frequency and produces the highest self-absorbed S-values in each organ, while Y-86 emits γ-rays with high energy and frequency which results in the highest cross-absorbed S-values for non-neighbouring organs. Differences between S-values for self-irradiated organs were between 2% and 3%/g difference in body weight for most organs. For organs irradiating other organs outside the splanchnocoele (i.e. brain, testis and bladder), differences between S-values were lower than 1%/g. These appealing results can be used to assess variations in small animal dosimetry as a function of total-body mass. The generated database of S-values for various radionuclides can be used in the assessment of radiation dose to mice from different radiotracers in small animal PET experiments, thus offering quantitative figures for comparative dosimetry research in small animal models.
Bach, Cristina; Dauchy, Xavier; Severin, Isabelle; Munoz, Jean-François; Etienne, Serge; Chagnon, Marie-Christine
2014-11-01
The effect of sunlight exposure on chemical migration into PET-bottled waters was investigated. Bottled waters were exposed to natural sunlight for 2, 6 and 10 days. Migration was dependent on the type of water. Formaldehyde, acetaldehyde and Sb migration increased with sunlight exposure in ultrapure water. In carbonated waters, carbon dioxide promoted migration and only formaldehyde increased slightly due to sunlight. Since no aldehydes were detected in non-carbonated waters, we conclude that sunlight exposure has no effect. Concerning Sb, its migration levels were higher in carbonated waters. No unpredictable NIAS were identified in PET-bottled water extracts. Cyto-genotoxicity (Ames and micronucleus assays) and potential endocrine disruption effects (transcriptional-reporter gene assays) were checked in bottled water extracts using bacteria (Salmonella typhimurium) and human cell lines (HepG2 and MDA-MB453-kb2). PET-bottled water extracts did not induce any toxic effects (cyto-genotoxicity, estrogenic or anti-androgenic activity) in vitro at relevant consumer-exposure levels. Copyright © 2014 Elsevier Ltd. All rights reserved.
Raghuraman, Kannan; Katti, Kavita K; Barbour, Leonard J; Pillarsetty, Nagavarakishore; Barnes, Charles L; Katti, Kattesh V
2003-06-11
Phosphorus functionalized trimeric alanine compounds (l)- and (d)-P(CH(2)NHCH(CH(3))COOH)(3) 2 are prepared in 90% yields by the Mannich reaction of Tris(hydroxymethyl)phosphine 1 with (l)- or (d)- Alanine in aqueous media. The hydration properties of (l)-2 and (d)-2 in water and water-methanol mixtures are described. The crystal structure analysis of (l)-2.4H(2)O, reveals that the alanine molecules pack to form two-dimensional bilayers running parallel to (001). The layered structural motif depicts two closely packed monolayers of 2 each oriented with its phosphorus atoms projected at the center of the bilayer and adjacent monolayers are held together by hydrogen bonds between amine and carboxylate groups. The water bilayers are juxtaposed with the H-bonded alanine trimers leading to 18-membered (H(2)O)(18) water rings. Exposure of aqueous solution of (l)-2 and (d)-2 to methanol vapors resulted in closely packed (l)-2 and (d)-2 solvated with mixed water-methanol (H(2)O)(15)(CH(3)OH)(3) clusters. The O-O distances in the mixed methanol-water clusters of (l)-2.3H(2)O.CH(3)OH and (d)-2.3H(2)O.CH(3)OH (O-O(average) = 2.857 A) are nearly identical to the O-O distance observed in the supramolecular (H(2)O)(18) water structure (O-O(average) = 2.859 A) implying the retention of the hydrogen bonded structure in water despite the accommodation of hydrophobic methanol groups within the supramolecular (H(2)O)(15)(CH(3)OH)(3) framework. The O-O distances in (l)-2.3H(2)O.CH(3)OH and (d)-2.3H(2)O.CH(3)OH and in (H(2)O)(18) are very close to the O-O distance reported for liquid water (2.85 A).
Fully Transparent Quantum Dot Light-Emitting Diode with a Laminated Top Graphene Anode.
Yao, Li; Fang, Xin; Gu, Wei; Zhai, Wenhao; Wan, Yi; Xie, Xixi; Xu, Wanjin; Pi, Xiaodong; Ran, Guangzhao; Qin, Guogang
2017-07-19
A new method to employ graphene as top electrode was introduced, and based on that, fully transparent quantum dot light-emitting diodes (T-QLEDs) were successfully fabricated through a lamination process. We adopted the widely used wet transfer method to transfer bilayer graphene (BG) on polydimethylsiloxane/polyethylene terephthalate (PDMS/PET) substrate. The sheet resistance of graphene reduced to ∼540 Ω/□ through transferring BG for 3 times on the PDMS/PET. The T-QLED has an inverted device structure of glass/indium tin oxide (ITO)/ZnO nanoparticles/(CdSSe/ZnS quantum dots (QDs))/1,1-bis[(di-4-tolylamino)phenyl] cyclohexane (TAPC)/MoO 3 /graphene/PDMS/PET. The graphene anode on PDMS/PET substrate can be directly laminated on the MoO 3 /TAPC/(CdSSe/ZnS QDs)/ZnO nanoparticles/ITO/glass, which relied on the van der Waals interaction between the graphene/PDMS and the MoO 3 . The transmittance of the T-QLED is 79.4% at its main electroluminescence peak wavelength of 622 nm.
Mühlematter, Urs J; Nagel, Hannes W; Becker, Anton; Mueller, Julian; Vokinger, Kerstin N; de Galiza Barbosa, Felipe; Ter Voert, Edwin E G T; Veit-Haibach, Patrick; Burger, Irene A
2018-05-31
Accurate attenuation correction (AC) is an inherent problem of positron emission tomography magnetic resonance imaging (PET/MRI) systems. Simulation studies showed that time-of-flight (TOF) detectors can reduce PET quantification errors in MRI-based AC. However, its impact on lesion detection in a clinical setting with 18 F-choline has not yet been evaluated. Therefore, we compared TOF and non-TOF 18 F-choline PET for absolute and relative difference in standard uptake values (SUV) and investigated the detection rate of metastases in prostate cancer patients. Non-TOF SUV was significantly lower compared to TOF in all osseous structures, except the skull, in primary lesions of the prostate, and in pelvic nodal and osseous metastasis. Concerning lymph node metastases, both experienced readers detected 16/19 (84%) on TOF PET, whereas on non-TOF PET readers 1 and 2 detected 11 (58%), and 14 (73%), respectively. With TOF PET readers 1 and 2 detected 14/15 (93%) and 11/15 (73%) bone metastases, respectively, whereas detection rate with non-TOF PET was 73% (11/15) for reader 1 and 53% (8/15) for reader 2. The interreader agreement was good for osseous metastasis detection on TOF (kappa 0.636, 95% confidence interval [CI] 0.453-0.810) and moderate on non-TOF (kappa = 0.600, CI 0.438-0.780). TOF reconstruction for 18 F-choline PET/MRI shows higher SUV measurements compared to non-TOF reconstructions in physiological osseous structures as well as pelvic malignancies. Our results suggest that addition of TOF information has a positive impact on lesion detection rate for lymph node and bone metastasis in prostate cancer patients.
Solar Disinfection of Viruses in Polyethylene Terephthalate Bottles.
Carratalà, Anna; Dionisio Calado, Alex; Mattle, Michael J; Meierhofer, Regula; Luzi, Samuel; Kohn, Tamar
2016-01-01
Solar disinfection (SODIS) of drinking water in polyethylene terephthalate (PET) bottles is a simple, efficient point-of-use technique for the inactivation of many bacterial pathogens. In contrast, the efficiency of SODIS against viruses is not well known. In this work, we studied the inactivation of bacteriophages (MS2 and ϕX174) and human viruses (echovirus 11 and adenovirus type 2) by SODIS. We conducted experiments in PET bottles exposed to (simulated) sunlight at different temperatures (15, 22, 26, and 40°C) and in water sources of diverse compositions and origins (India and Switzerland). Good inactivation of MS2 (>6-log inactivation after exposure to a total fluence of 1.34 kJ/cm(2)) was achieved in Swiss tap water at 22°C, while less-efficient inactivation was observed in Indian waters and for echovirus (1.5-log inactivation at the same fluence). The DNA viruses studied, ϕX174 and adenovirus, were resistant to SODIS, and the inactivation observed was equivalent to that occurring in the dark. High temperatures enhanced MS2 inactivation substantially; at 40°C, 3-log inactivation was achieved in Swiss tap water after exposure to a fluence of only 0.18 kJ/cm(2). Overall, our findings demonstrate that SODIS may reduce the load of single-stranded RNA (ssRNA) viruses, such as echoviruses, particularly at high temperatures and in photoreactive matrices. In contrast, complementary measures may be needed to ensure efficient inactivation during SODIS of DNA viruses resistant to oxidation. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Acute marijuana effects on rCBF and cognition: a PET study.
O'Leary, D S; Block, R I; Flaum, M; Schultz, S K; Boles Ponto, L L; Watkins, G L; Hurtig, R R; Andreasen, N C; Hichwa, R D
2000-11-27
The effects of smoking marijuana on cognition and brain function were assessed with PET using H2(15)O. Regional cerebral blood flow (rCBF) was measured in five recreational users before and after smoking a marijuana cigarette, as they repeatedly performed an auditory attention task. Blood flow increased following smoking in a number of paralimbic brain regions (e.g. orbital frontal lobes, insula, temporal poles) and in anterior cingulate and cerebellum. Large reductions in rCBF were observed in temporal lobe regions that are sensitive to auditory attention effects. Brain regions showing increased rCBF may mediate the intoxicating and mood-related effects of smoking marijuana, whereas reduction of task-related rCBF in temporal lobe cortices may account for the impaired cognitive functions associated with acute intoxication.
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Specific Chemical (Active Ingredient) Information
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Where to start with pest control
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
National Pesticide Information Center - Home Page
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Pesticides and the Environment
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Other/Inert Ingredients in Pesticides
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
NASA Astrophysics Data System (ADS)
Elabid, Amel E. A.; Zhang, Jie; Shi, Jianjun; Guo, Ying; Ding, Ke; Zhang, Jing
2016-07-01
Polyethylene terephthalate (PET) fiber and textile is one of the largest synthetic polymer commodity in the world. The great energy consumption and pollution caused by the high temperature and pressure dyeing of PET fibers and fabrics with disperse dyes has been caused concern these years. In this study, an atmospheric pressure plasma with fine and uniform filament discharge operated at 20 kHz has been used to improve the low temperature dyeability of PET fabric at 95 °C with three cation disperse dyes: Red 73, Blue 183 and Yellow 211. The dyes uptake percentage of the treated PET fabrics was observed to increase as twice as much of untreated fabric. The color strength rate was increased more than 20%. The reducing of the water contact angle and the raising of the capillary height of treated PET fabric strip indicate its hydrophilicity improvement. Scanning electron microscope (SEM) results display nano to micro size of etching pits appeared uniformly on the fiber surface of the treated PET. Simultaneously, X-ray photoelectron spectroscopy (XPS) analysis indicates an increase of the oxygen content in the surface caused by the introduction of polar groups such as Cdbnd O and COOH. The rough surface with improved polar oxygen groups showed hydrophilicity and affinity to C.I. dispersive dyes and is believed to be caused by the strong and very fine filament discharge appearing randomly at one place at an instant but evenly at many places at a longer period. This increases the diffusion and absorption of the C.I. disperse dyes on the PET fiber surface, which improve its low temperature dyeability.
Gamma, Alex; Lehmann, Dietrich; Frei, Edi; Iwata, Kazuki; Pascual-Marqui, Roberto D; Vollenweider, Franz X
2004-06-01
The complementary strengths and weaknesses of established functional brain imaging methods (high spatial, low temporal resolution) and EEG-based techniques (low spatial, high temporal resolution) make their combined use a promising avenue for studying brain processes at a more fine-grained level. However, this strategy requires a better understanding of the relationship between hemodynamic/metabolic and neuroelectric measures of brain activity. We investigated possible correspondences between cerebral blood flow (CBF) as measured by [H2O]-PET and intracerebral electric activity computed by Low Resolution Brain Electromagnetic Tomography (LORETA) from scalp-recorded multichannel EEG in healthy human subjects during cognitive and pharmacological stimulation. The two imaging modalities were compared by descriptive, correlational, and variance analyses, the latter carried out using statistical parametric mapping (SPM99). Descriptive visual comparison showed a partial overlap between the sets of active brain regions detected by the two modalities. A number of exclusively positive correlations of neuroelectric activity with regional CBF were found across the whole EEG frequency range, including slow wave activity, the latter finding being in contrast to most previous studies conducted in patients. Analysis of variance revealed an extensive lack of statistically significant correspondences between brain activity changes as measured by PET vs. EEG-LORETA. In general, correspondences, to the extent they were found, were dependent on experimental condition, brain region, and EEG frequency. Copyright 2004 Wiley-Liss, Inc.
Effects of Insulin on Brain Glucose Metabolism in Impaired Glucose Tolerance
Hirvonen, Jussi; Virtanen, Kirsi A.; Nummenmaa, Lauri; Hannukainen, Jarna C.; Honka, Miikka-Juhani; Bucci, Marco; Nesterov, Sergey V.; Parkkola, Riitta; Rinne, Juha; Iozzo, Patricia; Nuutila, Pirjo
2011-01-01
OBJECTIVE Insulin stimulates brain glucose metabolism, but this effect of insulin is already maximal at fasting concentrations in healthy subjects. It is not known whether insulin is able to stimulate glucose metabolism above fasting concentrations in patients with impaired glucose tolerance. RESEARCH DESIGN AND METHODS We studied the effects of insulin on brain glucose metabolism and cerebral blood flow in 13 patients with impaired glucose tolerance and nine healthy subjects using positron emission tomography (PET). All subjects underwent PET with both [18F]fluorodeoxyglucose (for brain glucose metabolism) and [15O]H2O (for cerebral blood flow) in two separate conditions (in the fasting state and during a euglycemic-hyperinsulinemic clamp). Arterial blood samples were acquired during the PET scans to allow fully quantitative modeling. RESULTS The hyperinsulinemic clamp increased brain glucose metabolism only in patients with impaired glucose tolerance (whole brain: +18%, P = 0.001) but not in healthy subjects (whole brain: +3.9%, P = 0.373). The hyperinsulinemic clamp did not alter cerebral blood flow in either group. CONCLUSIONS We found that insulin stimulates brain glucose metabolism at physiological postprandial levels in patients with impaired glucose tolerance but not in healthy subjects. These results suggest that insulin stimulation of brain glucose metabolism is maximal at fasting concentrations in healthy subjects but not in patients with impaired glucose tolerance. PMID:21270256
Leynes, Andrew P; Yang, Jaewon; Wiesinger, Florian; Kaushik, Sandeep S; Shanbhag, Dattesh D; Seo, Youngho; Hope, Thomas A; Larson, Peder E Z
2018-05-01
Accurate quantification of uptake on PET images depends on accurate attenuation correction in reconstruction. Current MR-based attenuation correction methods for body PET use a fat and water map derived from a 2-echo Dixon MRI sequence in which bone is neglected. Ultrashort-echo-time or zero-echo-time (ZTE) pulse sequences can capture bone information. We propose the use of patient-specific multiparametric MRI consisting of Dixon MRI and proton-density-weighted ZTE MRI to directly synthesize pseudo-CT images with a deep learning model: we call this method ZTE and Dixon deep pseudo-CT (ZeDD CT). Methods: Twenty-six patients were scanned using an integrated 3-T time-of-flight PET/MRI system. Helical CT images of the patients were acquired separately. A deep convolutional neural network was trained to transform ZTE and Dixon MR images into pseudo-CT images. Ten patients were used for model training, and 16 patients were used for evaluation. Bone and soft-tissue lesions were identified, and the SUV max was measured. The root-mean-squared error (RMSE) was used to compare the MR-based attenuation correction with the ground-truth CT attenuation correction. Results: In total, 30 bone lesions and 60 soft-tissue lesions were evaluated. The RMSE in PET quantification was reduced by a factor of 4 for bone lesions (10.24% for Dixon PET and 2.68% for ZeDD PET) and by a factor of 1.5 for soft-tissue lesions (6.24% for Dixon PET and 4.07% for ZeDD PET). Conclusion: ZeDD CT produces natural-looking and quantitatively accurate pseudo-CT images and reduces error in pelvic PET/MRI attenuation correction compared with standard methods. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.
Ballanger, Benedicte; Lozano, Andres M; Moro, Elena; van Eimeren, Thilo; Hamani, Clement; Chen, Robert; Cilia, Roberto; Houle, Sylvain; Poon, Yu Yan; Lang, Anthony E; Strafella, Antonio P
2009-12-01
Patients with advanced Parkinson's disease (PD) develop disabling axial symptoms, including gait disturbances, freezing and postural instability poorly responsive to levodopa replacement therapy. The pedunculopontine nucleus (PPN) is involved in locomotion, control of posture, and behavioral states [i.e. wakefulness, rapid eye movement sleep]. Recent reports suggested that PPN modulation with deep brain stimulation (DBS) may be beneficial in the treatment of axial symptoms. However, the mechanisms underlying these effects are still unknown. We used [(15)O] H(2)O PET to investigate regional cerebral blood flow in three patients with advanced PD who underwent a new experimental surgical procedure with implantation of unilateral PPN-DBS. Patients were studied Off-medication with stimulator Off and On, both at rest and during a self-paced alternating motor task of the lower limbs. We used SPM2 for imaging data analysis, threshold P < 0.05 corrected at the cluster level. Stimulation induced significant regional cerebral blood flow increment in subcortical regions such as the thalamus (P < 0.006), cerebellum (P < 0.001), and midbrain region (P < 0.001) as well as different cortical areas involving medial sensorimotor cortex extending into caudal supplementary motor area (BA 4/6; P < 0.001). PPN-DBS in advanced PD resulted in blood flow and presumably neuronal activity changes in subcortical and cortical areas involved in balance and motor control, including the mesencephalic locomotor region (e.g. PPN) and closely interconnected structures within the cerebello-(rubro)-thalamo-cortical circuit. Whether these findings are associated with the DBS-PPN clinical effect remains to be proven. However, they suggest that PPN modulation may induce functional changes in neural networks associated with the control of lower limb movements. 2009 Wiley-Liss, Inc.
Detection of muscarinic receptors in the human lung using PET.
Visser, T J; van Waarde, A; van der Mark, T W; Kraan, J; Ensing, K; Willemsen, A T; Elsinga, P H; Vaalburg, W
1999-08-01
The characterization of pulmonary muscarinic receptors with PET is still in its infancy. Because approximately 70% of the lungs consists of air and pulmonary muscarinic receptor densities are low, ligands with high receptor affinity are required to obtain reasonable signal-to-noise ratios on PET images. Therefore, the potent 11C-labeled muscarinic antagonist N-methyl-piperidin-4-yl 2-cyclohexyl-2-hydroxy-2-phenylacetate methiodide ([R]-VC-002) was developed. We administered this radioligand to four healthy human volunteers to examine its suitability for studying pulmonary muscarinic receptors in vivo. [11C]VC-002 (185 MBq, specific activity > 7.4 TBq/mmol) was intravenously injected on 2 separate days, with an interval of at least 1 wk. On the first day the volunteers were not pretreated, but on the second day they received the anticholinergic glycopyrronium bromide (Robinul; 2 x 0.1 mg intravenous) 25 and 30 min before the injection of the radiopharmaceutical. C[15O]O scans (approximately 740 MBq [20 mCi] by inhalation) were acquired before the receptor scan to calculate pulmonary blood volume. On PET images of the thorax, the lungs were clearly visible. After the volunteer was pretreated with glycopyrronium bromide, pulmonary uptake of the radioligand was reduced to 32%+/-12% of the control value at 60 min postinjection and the lungs could no longer be seen. (R)-[11C]-VC-002 was rapidly cleared from plasma and was slowly metabolized during the time course (60 min) of the PET scan. The fraction of radioligand representing parent compound decreased from 99.9% at the time of injection to 82% at 40-60 min postinjection, both in the presence and absence of Robinul. Pulmonary tissue-to-plasma ratios, calculated on a count-per-minute-per-gram basis, reached a plateau value of 17.8+/-1.2 at 40-50 min postinjection. [11C]VC-002 appears to be suitable for in vivo studies of pulmonary cholinoceptors.
Photophysical and photochemical effects of UV and VUV photo-oxidation and photolysis on PET and PEN
NASA Astrophysics Data System (ADS)
Morgan, Andrew
Polyethylene Terephthalate (PET) is a widely used polymer in the bottling, packaging, and clothing industry. In recent years an increasing global demand for PET has taken place due to the Solar Disinfection (SODIS) process. SODIS is a method of sterilizing fresh water into drinkable water. The PET bottles are used in the process to contain the water during solar irradiation due to its highly transparent optical property. Alongside PET, polyethylene 2,6-napthalate (PEN) is used in bottling and flexible electronic applications. The surface of PEN would need to be modified to control the hydrophilicity and the interaction it exudes as a substrate. The UV light absorption properties of PET and PEN are of great importance for many applications, and thus needs to be studied along with its photochemical resistance. The optical and chemical nature of PET was studied as it was treated by UV photo-oxidation, photo-ozonation, and photolysis under atmospheric pressure. Another investigation was also used to study PEN and PET as they are treated by vacuum UV (VUV) photo-oxidation, VUV photolysis, and remote oxygen reactions. The extent of the photoreactions' effect into the depth of the polymers is examined as treatment conditions are changed. The different experimental methods established the rate of several competing photoreactions on PET and PEN during irradiance, and their effect on the optical quality of the polymers.
NASA Astrophysics Data System (ADS)
Canadas, Mario; Embid, Miguel; Lage, Eduardo; Desco, Manuel; Vaquero, Juan José; Perez, José Manuel
2011-02-01
In this work, we compare two commercial positron emission tomography (PET) scanners installed at CIEMAT (Madrid, Spain): the ClearPET and the rPET-1. These systems have significant geometrical differences, such as the axial field of view (110 mm on ClearPET versus 45.6 mm on rPET-1), the configuration of the detectors (whole ring on ClearPET versus one pair of planar blocks on rPET-1) and the use of an axial shift between ClearPET detector modules. We used an assessment procedure that fulfilled the recommendations of the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard. The methodology includes studies of spatial resolution, sensitivity, scatter fraction, count losses and image quality. Our experiments showed a central spatial resolution of 1.5 mm (transaxial), 3.2 mm (axial) for the ClearPET and 1.5 mm (transaxial), 1.6 mm (axial) for the rPET-1, with a small variation across the transverse axis on both scanners ( 1 mm). The absolute sensitivity at the centre of the field of view was 4.7% for the ClearPET and 1.0% for the rPET-1. The peak noise equivalent counting rate for the mouse-sized phantom was 73.4 kcps reached at 0.51 MBq/mL on the ClearPET and 29.2 kcps at 1.35 MBq/mL on the rPET-1. The recovery coefficients measured using the image quality phantom ranged from 0.11 to 0.89 on the ClearPET and from 0.14 to 0.81 on the rPET-1. The overall performance shows that both the ClearPET and the rPET-1 systems are very suitable for preclinical research and imaging of small animals.
Zhu, H; Wang, F; Guo, X Y; Li, L Q; Duan, D B; Liu, Z B; Yang, Z
2018-04-18
To provide useful information for the further production and application of this novel radio-nuclide for potential clinical application. 124 Te (p,n) 124 I nuclide reaction was used for the 124 I production. Firstly, the target material, 124 TeO 2 (200 mg) and Al2O3 (30 mg) mixture, were compressed into the round platinum based solid target by tablet device. HM-20 medical cyclotron was applied to irradiate the solid target slice for 6-10 h with helium and water cooling. Then, the radiated solid target was placed for 12 h (overnight) to decay the radioactive impurity; finally, 124 I was be purified by dry distillation using 1 mL/min nitrogen for about 6 hours and radiochemical separation methods. Micro-PET imaging studies were performed to investigate the metabolism properties and thyroid imaging ability of 124 I.After 740 kBq 124 I was injected intravenously into the tail vein of the normal mice, the animals were imaged with micro-PET and infused with CT. The micro-PET/CT infusion imaging revealed actual state 124 I's metabolism in the mice. It was been successfully applied for 200 mg 124 TeO 2 plating by the tablet device on the surface of platinum. It showed smooth, dense surface and without obviously pits and cracks. The enriched 124 Te target was irradiated for 6 to 10 hours at about 12.0 MeV with 20 μA current on HM-20 cyclotron. Then 370-1 110 MBq 124 I could be produced on the solid target after irradiation and 370-740 MBq high specific activity could be collected afterdry distillation separation and radio-chemical purification. 124 I product was finally dissolved in 0.01 mol/L NaOH for the future distribution. The gamma spectrum of the produced 124 I-solution showed that radionuclide purity was over 80.0%. The micro-PET imaging of 124 I in the normal mice exhibited the thyroid and stomach accumulations and kidney metabolism, the bladder could also be clearly visible, which was in accordance with what was previously reported. To the best of our knowledge, it was the first production of 124 I report in China. In this study, the preparation of 124 TeO 2 solid target was successfully carried out by using the tablet device. After irradiation of the 124 TeO 2 solid target and radio-chemical purification, we successfully produced 370-740 MBq high specific activity 124 I by a cyclotron for biomedical application, and micro-PET imaging of 124 I in normal mice exhibited the thyroid accumulations. Also, slight uptake in stomach were also monitored with almost nonuptake in other organs in the micro-PET imaging. The production of 124 I is expected to provide a new solid target radionuclide for the scientific research and potential clinical application of our country.
Houri, Daisuke; Koo, Chung Mo
2015-09-01
The past few years have seen a demand for drinking water in contemporary society with a focus on safety and taste. Mineral water is now marketed as a popular commercial product and, partly due to health concerns, the production. For the study, a comparison was carried out of water samples from 9 types of polyethylene terephthalate (PET) bottled water sold in South Korea as well as from tap water in the cities of Seoul and Chuncheon. These were compared with samples of Japanese PET bottled water in order to determine shared commonalities and identify individual characteristics. To evaluate water quality objectively, we quantified the elements contained in the water samples. Samples were assessed not with the usual sensory evaluation but with the evaluation approach advocated by Hashimoto et al. which employs the Water Index of Taste and the Water Index of Health. The levels of water quality obtained were compared with the "Prerequisites for Tasty Water" and the "Standards for Tasty Water" devised for city water. The PET Bottled water varieties analyzed in this study-Seoksu, Icis, Bong Pyong, Soon Soo 100, Dong Won Saem Mul, GI JANG SOO and DIAMOND-showed the Water Index of Taste ≥ 2.0 and the Water Index of Health ≥ 5.2, which we classified as tasty/healthy water. SamDaSoo and NamiNeral can be classified as tasty water due to their values of the Water Index of Taste ≥ 2.0 and the Water Index of Health < 5.2. The South Korean PET bottled water studied here fulfills the "Water Index of Taste," "Water Index of Health," "Standard for Tasty Water" and "Prerequisites for Tasty Water" that Japanese people value for city water. We can conclude that bottled water which meets water quality requirements will be considered good-tasting by a majority of people.
The Cerebellum and Emotional Experience
Turner, Beth M.; Paradiso, Sergio; Marvel, Cherie L.; Pierson, Ronald; Boles Ponto, Laura L.; Hichwa, Richard D.; Robinson, Robert G.
2007-01-01
Summary While the role of the cerebellum in motor coordination is widely accepted, the notion that it is involved in emotion has only recently gained popularity. To date, functional neuroimaging has not been used in combination with lesion studies to elucidate the role of the cerebellum in the processing of emotional material. We examined six participants with cerebellar stroke and nine age and education matched healthy volunteers. In addition to a complete neuropsychological, neurologic, and psychiatric examination, participants underwent [15O]water positron emission tomography (PET) while responding to emotion-evoking visual stimuli. Cerebellar lesions were associated with reduced pleasant experience in response to happiness-evoking stimuli. Stroke patients reported an unpleasant experience to frightening stimuli similar to healthy controls, yet showed significantly lower activity in the right ventral lateral and left dorsolateral prefrontal cortex, amygdala, thalamus, and retrosplenial cingulate gyrus. Frightening stimuli led to increased activity in the ventral medial prefrontal, anterior cingulate, pulvinar, and insular cortex. This suggests that alternate neural circuitry became responsible for maintaining the evolutionarily critical fear response after cerebellar damage. PMID:17123557
Duoplasmatron source modifications for 3He+ operation
NASA Astrophysics Data System (ADS)
Schmidt, C. W.; Popovic, M.
1998-02-01
A duoplasmatron ion source is used to produce 25 mA of 3He+ with a pulse width of ˜80 ms at 360 Hz for acceleration to 10.5 MeV. At this energy, 3He striking water or carbon targets can produce short lived isotopes of 11C, 13N, 15O, and 18F for medical positron emission tomography (PET). A duoplasmatron ion source was chosen originally since it is capable of a sufficient singly charged helium beam with an acceptable gas consumption. Stable long-term operation of the source required a change in the filament material to molybdenum, and a careful understanding of the oxide filament conditioning, operation and geometry. Other improvements, particularly in the electronics, were helpful to increasing the reliability. The source has operated for many months at ˜2.5% duty factor without significant problems and with good stability. We report here the effort that was done to make this source understandable and reliable.
Schmidt, Gerwin P; Baur-Melnyk, Andrea; Haug, Alexander; Heinemann, Volker; Bauerfeind, Ingo; Reiser, Maximilian F; Schoenberg, Stefan O
2008-01-01
To compare the diagnostic accuracy for the detection of tumor recurrence in breast cancer patients using whole-body-MRI (WB-MRI) at 1.5 or 3T compared to FDG-PET-CT. Thirty-three female patients with breast cancer and suspicion of recurrence underwent FDG-PET-CT and WB-MRI. Coronal T1w-TSE- and STIR-sequences, HASTE-imaging of the lungs, contrast-enhanced T1w- and T2w-TSE-sequences of the liver, brain and abdomen were performed, using a WB-MRI-scanner at 1.5 (n=23) or 3T (n=10). Presence of local recurrence, lymph node involvement and distant metastatic disease was assessed using clinical and radiological follow-up as a standard of reference. Tumor recurrence was found in 20 of 33 patients. Overall 186 malignant foci were detected with WB-MRI and PET-CT. Both modalities revealed two recurrent tumors of the breast. PET-CT detected more lymph node metastases (n=21) than WB-MRI (n=16). WB-MRI was more precise in the detection of distant metastases (n=154 versus n=147). Sensitivity was 93% (172/186) and 91% (170/186) for WB-MRI and PET-CT, specificity was 86% (66/77) and 90% (69/77), respectively. Examination times for WB-MRI at 1.5 and 3T were 51 and 43 min, respectively, examination time for PET-CT was 103 min. WB-MRI and PET-CT are useful for the detection of tumor recurrence in the follow-up of breast cancer. WB-MRI is highly sensitive to distant metastatic disease. PET-CT is more sensitive in detecting lymph node involvement. Tumor screening with WB-MRI is feasible at 1.5 and 3T, scan time is further reduced at 3T with identical resolution.
Houri, Daisuke; Koo, Chung Mo
2015-01-01
Background The past few years have seen a demand for drinking water in contemporary society with a focus on safety and taste. Mineral water is now marketed as a popular commercial product and, partly due to health concerns, the production. Methods For the study, a comparison was carried out of water samples from 9 types of polyethylene terephthalate (PET) bottled water sold in South Korea as well as from tap water in the cities of Seoul and Chuncheon. These were compared with samples of Japanese PET bottled water in order to determine shared commonalities and identify individual characteristics. To evaluate water quality objectively, we quantified the elements contained in the water samples. Samples were assessed not with the usual sensory evaluation but with the evaluation approach advocated by Hashimoto et al. which employs the Water Index of Taste and the Water Index of Health. The levels of water quality obtained were compared with the “Prerequisites for Tasty Water” and the “Standards for Tasty Water” devised for city water. Results The PET Bottled water varieties analyzed in this study—Seoksu, Icis, Bong Pyong, Soon Soo 100, Dong Won Saem Mul, GI JANG SOO and DIAMOND—showed the Water Index of Taste ≥ 2.0 and the Water Index of Health ≥ 5.2, which we classified as tasty/healthy water. SamDaSoo and NamiNeral can be classified as tasty water due to their values of the Water Index of Taste ≥ 2.0 and the Water Index of Health < 5.2. Conclusion The South Korean PET bottled water studied here fulfills the “Water Index of Taste,” “Water Index of Health,” “Standard for Tasty Water” and “Prerequisites for Tasty Water” that Japanese people value for city water. We can conclude that bottled water which meets water quality requirements will be considered good-tasting by a majority of people. PMID:26538797
Code of Federal Regulations, 2010 CFR
2010-07-01
... building, public transportation vehicle, or location designated as a swimming beach, or any structure or... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Pets. 2.15 Section 2.15 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR RESOURCE PROTECTION, PUBLIC...
Lawrence, Wayne R; Yang, Mo; Lin, Shao; Wang, Si-Quan; Liu, Yimin; Ma, Huimin; Chen, Duo-Hong; Yang, Bo-Yi; Zeng, Xiao-Wen; Hu, Li-Wen; Dong, Guang-Hui
2018-07-01
The effect of ambient air pollution exposure on childhood hypertension has emerged as a concern in China, and previous studies suggested pet ownership is associated with lower blood pressure (BP). However, limited information exists on the interactive effects pet ownership and air pollution exposure has on hypertension. We investigated the interactions between exposure to pet ownership and air pollutants on hypertension in Chinese children. 9354 students in twenty-four elementary and middle schools (aged 5-17 years) in Northeastern China were evaluated during 2012-2013. Four-year average concentrations of particulate matter with aerodynamic diameter of ≤10 μm (PM 10 ), SO 2 , NO 2 , and O 3 , were collected in the 24 districts from 2009 to 2012. Hypertension was defined as average diastolic or systolic BP (three time measurements) in the 95th percentile or higher based on height, age, and sex. To examine effects, two-level regression analysis was used, controlling covariates. Consistent interactions between exposure to pet and air pollutants were observed. Compared to children exposed to pet, those not exposed exhibited consistently stronger effects of air pollution. The highest odds ratios (ORs) per 30.6 μg/m 3 increase in PM 10 were 1.79 (95%confidence interval [95%CI]: 1.29-2.50) in children without current pet exposure compared to 1.24 (95%CI: 0.85-1.82) in children with current pet exposure. As for BP, only O 3 had an interaction for all exposure to pet ownership types, and showed lower BP in children exposed to pet. The increases in mean diastolic BP per 46.3 μg/m 3 increase in O 3 were 0.60 mmHg (95%CI: 0.21, 0.48) in children without pet exposure in utero compared with 0.34 mmHg (95%CI: 0.21, 0.48) in their counterparts. When stratified by age, pet exposure was more protective among younger children. In conclusion, in this large population-based cohort, pet ownership is associated with smaller associations between air pollution and hypertension in children, suggesting pet ownership reduces susceptibility to the health effects of pollutants. Copyright © 2018 Elsevier Ltd. All rights reserved.
Why do I have cockroaches in my home?
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
PDMS-based triboelectric and transparent nanogenerators with ZnO nanorod arrays.
Ko, Yeong Hwan; Nagaraju, Goli; Lee, Soo Hyun; Yu, Jae Su
2014-05-14
Vertically-grown ZnO nanorod arrays (NRAs) on indium tin oxide (ITO)-coated polyethylene terephthalate (PET), as a top electrode of nanogenerators, were investigated for the antireflective property as well as an efficient contact surface in bare polydimethysiloxane (PDMS)-based triboelectric nanogenerators. Compared to conventional ITO-coated PET (i.e., ITO/PET), the ZnO NRAs considerably suppressed the reflectance from 20 to 9.7% at wavelengths of 300-1100 nm, creating a highly transparent top electrode, as demonstrated by theoretical analysis. Also, the interval time between the peaks of generated output voltage under external pushing forces was significantly decreased from 1.84 to 0.19 s because the reduced contact area of the PDMS by discrete surfaces of the ZnO NRAs on ITO/PET causes a rapid sequence for triboelectric charge generation process including rubbing and separating. Therefore, the use of this top electrode enabled to operate the transparent PDMS-based triboelectric nanogenerator at high frequency of external pushing force. Under different external forces of 0.3-10 kgf, the output voltage and current were also characterized.
Does Delayed-Time-Point Imaging Improve 18F-FDG-PET in Patients With MALT Lymphoma?
Mayerhoefer, Marius E.; Giraudo, Chiara; Senn, Daniela; Hartenbach, Markus; Weber, Michael; Rausch, Ivo; Kiesewetter, Barbara; Herold, Christian J.; Hacker, Marcus; Pones, Matthias; Simonitsch-Klupp, Ingrid; Müllauer, Leonhard; Dolak, Werner; Lukas, Julius; Raderer, Markus
2016-01-01
Purpose To determine whether in patients with extranodal marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue lymphoma (MALT), delayed–time-point 2-18F-fluoro-2-deoxy-d-glucose-positron emission tomography (18F-FDG-PET) performs better than standard–time-point 18F-FDG-PET. Materials and Methods Patients with untreated histologically verified MALT lymphoma, who were undergoing pretherapeutic 18F-FDG-PET/computed tomography (CT) and consecutive 18F-FDG-PET/magnetic resonance imaging (MRI), using a single 18F-FDG injection, in the course of a larger-scale prospective trial, were included. Region-based sensitivity and specificity, and patient-based sensitivity of the respective 18F-FDG-PET scans at time points 1 (45–60 minutes after tracer injection, TP1) and 2 (100–150 minutes after tracer injection, TP2), relative to the reference standard, were calculated. Lesion-to-liver and lesion-to-blood SUVmax (maximum standardized uptake values) ratios were also assessed. Results 18F-FDG-PET at TP1 was true positive in 15 o f 23 involved regions, and 18F-FDG-PET at TP2 was true-positive in 20 of 23 involved regions; no false-positive regions were noted. Accordingly, region-based sensitivities and specificities were 65.2% (confidence interval [CI], 45.73%–84.67%) and 100% (CI, 100%-100%) for 18F-FDG-PET at TP1; and 87.0% (CI, 73.26%–100%) and 100% (CI, 100%-100%) for 18F-FDG-PET at TP2, respectively. FDG-PET at TP1 detected lymphoma in at least one nodal or extranodal region in 7 of 13 patients, and 18F-FDG-PET at TP2 in 10 of 13 patients; accordingly, patient-based sensitivity was 53.8% (CI, 26.7%–80.9%) for 18F-FDG-PET at TP1, and 76.9% (CI, 54.0%–99.8%) for 18F-FDG-PET at TP2. Lesion-to-liver and lesion-to-blood maximum standardized uptake value ratios were significantly lower at TP1 (ratios, 1.05 ± 0.40 and 1.52 ± 0.62) than at TP2 (ratios, 1.67 ± 0.74 and 2.56 ± 1.10; P = 0.003 and P = 0.001). Conclusions Delayed–time-point imaging may improve 18F-FDG-PET in MALT lymphoma. PMID:26402137
NASA Astrophysics Data System (ADS)
Park, Jeong-Il; Heo, Jin Hyuck; Park, Sung-Hyun; Hong, Ki Il; Jeong, Hak Gee; Im, Sang Hyuk; Kim, Han-Ki
2017-02-01
We fabricated high-performance flexible CH3NH3PbI3 (MAPbI3) perovskite solar cells with a power conversion efficiency of 15.5% on roll-to-roll sputtered ITO films on 60 μm-thick colourless polyimide (CPI) substrate. Due to the thermal stability of the CPI substrate, an ITO/CPI sample subjected to rapid thermal annealing at 300 °C showed a low sheet resistance of 57.8 Ω/square and high transmittance of 83.6%, which are better values than those of an ITO/PET sample. Outer and inner bending tests demonstrated that the mechanical flexibility of the ITO/CPI was superior to that of the conventional ITO/PET sample owing to the thinness of the CPI substrate. In addition, due to its good mechanical flexibility, the ITO/CPI showed no change in resistance after 10,000 cycle outer and inner dynamic fatigue tests. Flexible perovskite solar cells with the structure of Au/PTAA/MAPbI3/ZnO/ITO/CPI showed a high power conversion efficiency of 15.5%. The successful operation of these flexible perovskite solar cells on ITO/CPI substrate indicated that the ITO film on thermally stable CPI substrate is a promising of flexible substrate for high-temperature processing, a finding likely to advance the commercialization of cost-efficient flexible perovskite solar cells.
2015-10-01
therapy in a human patient. These images are from a 63 y/o male with NSCLC participating in our exploratory clinical trial of FLT- PET “flare”. (a... PET in a human NSCLC patient. Results: In NSCLC cells in vitro, we identified a burst in thymidine salvage pathway activity, assessed by 3H...25 Human PET imaging IRB approval was obtained through the University of Pennsylvania Institutional Review Board for use of FLT- PET /CT
Borowiak, Robert; Reichardt, Wilfried; Kurzhunov, Dmitry; Schuch, Christian; Leupold, Jochen; Krafft, Axel Joachim; Reisert, Marco; Lange, Thomas; Fischer, Elmar; Bock, Michael
2017-08-01
In this initial work, the in vivo degradation of 17 O-labeled glucose was studied during cellular glycolysis. To monitor cellular glucose metabolism, direct 17 O-magnetic resonance spectroscopy (MRS) was used in the mouse brain at 9.4 T. Non-localized spectra were acquired with a custom-built transmit/receive (Tx/Rx) two-turn surface coil and a free induction decay (FID) sequence with a short TR of 5.4 ms. The dynamics of labeled oxygen in the anomeric 1-OH and 6-CH 2 OH groups was detected using a Hankel-Lanczos singular value decomposition (HLSVD) algorithm for water suppression. Time-resolved 17 O-MRS (temporal resolution, 42/10.5 s) was performed in 10 anesthetized (1.25% isoflurane) mice after injection of a 2.2 M solution containing 2.5 mg/g body weight of differently labeled 17 O-glucose dissolved in 0.9% physiological saline. From a pharmacokinetic model fit of the H 2 17 O concentration-time course, a mean apparent cerebral metabolic rate of 17 O-labeled glucose in mouse brain of CMR Glc = 0.07 ± 0.02 μmol/g/min was extracted, which is of the same order of magnitude as a literature value of 0.26 ± 0.06 μmol/g/min reported by 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography (PET). In addition, we studied the chemical exchange kinetics of aqueous solutions of 17 O-labeled glucose at the C1 and C6 positions with dynamic 17 O-MRS. In conclusion, the results of the exchange and in vivo experiments demonstrate that the C6- 17 OH label in the 6-CH 2 OH group is transformed only glycolytically by the enzyme enolase into the metabolic end-product H 2 17 O, whereas C1- 17 OH ends up in water via direct hydrolysis as well as glycolysis. Therefore, dynamic 17 O-MRS of highly labeled 17 O-glucose could provide a valuable non-radioactive alternative to FDG PET in order to investigate glucose metabolism. Copyright © 2017 John Wiley & Sons, Ltd.
Preparation of flexible TiO2 photoelectrodes for dye-sensitized solar cells
NASA Astrophysics Data System (ADS)
Li, Wen-Ren; Wang, Hsiu-Hsuan; Lin, Chia-Feng; Su, Chaochin
2014-09-01
Dye-sensitized solar cells (DSSCs) based on nanocrystalline TiO2 photoelectrodes on indium tin oxide (ITO) coated polymer substrates have drawn great attention due to its lightweight, flexibility and advantages in commercial applications. However, the thermal instability of polymer substrates limits the process temperature to below 150 °C. In order to assure high and firm interparticle connection between TiO2 nanocrystals (TiO2-NC) and polymer substrates, the post-treatment of flexible TiO2 photoelectrodes (F-TiO2-PE) by mechanical compression was employed. In this work, Degussa P25 TiO2-NC was mixed with tert-butyl alcohol and DI-water to form TiO2 paste. F-TiO2-PE was then prepared by coating the TiO2 paste onto ITO coated polyethylene terephthalate (PET) substrate using doctor blade followed by low temperature sintering at 120 °C for 2 hours. To study the effect of mechanical compression, we applied 50 and 100 kg/cm2 pressure on TiO2/PET to complete the fabrication of F-TiO2-PE. The surface morphology of F-TiO2-PE was characterized using scanning electron microscopy. The resultant F-TiO2-PE sample exhibited a smooth, crack-free structure indicating the great improvement in the interparticle connection of TiO2-NC. Increase of compression pressure could lead to the increase of DSSC photoconversion efficiency. The best photoconversion efficiency of 4.19 % (open circuit voltage (Voc) = 0.79 V, short-circuit photocurrent density (Jsc) = 7.75 mA/cm2, fill factor (FF) = 0.68) was obtained for the F-TiO2-PE device, which showed great enhancement compared with the F-TiO2-PE cell without compression treatment. The effect of compression in DSSC performance was vindicated by the electrochemical impedance spectroscopy measurement.
A simulation study of a C-shaped in-beam PET system for dose verification in carbon ion therapy
NASA Astrophysics Data System (ADS)
Jung An, Su; Beak, Cheol-Ha; Lee, Kisung; Hyun Chung, Yong
2013-01-01
The application of hadrons such as carbon ions is being developed for the treatment of cancer. The effectiveness of such a technique is due to the eligibility of charged particles in delivering most of their energy near the end of the range, called the Bragg peak. However, accurate verification of dose delivery is required since misalignment of the hadron beam can cause serious damage to normal tissue. PET scanners can be utilized to track the carbon beam to the tumor by imaging the trail of the hadron-induced positron emitters in the irradiated volume. In this study, we designed and evaluated (through Monte Carlo simulations) an in-beam PET scanner for monitoring patient dose in carbon beam therapy. A C-shaped PET and a partial-ring PET were designed to avoid interference between the PET detectors and the therapeutic carbon beam delivery. Their performance was compared with that of a full-ring PET scanner. The C-shaped, partial-ring, and full-ring scanners consisted of 14, 12, and 16 detector modules, respectively, with a 30.2 cm inner diameter for brain imaging. Each detector module was composed of a 13×13 array of 4.0 mm×4.0 mm×20.0 mm LYSO crystals and four round 25.4 mm diameter PMTs. To estimate the production yield of positron emitters such as 10C, 11C, and 15O, a cylindrical PMMA phantom (diameter, 20 cm; thickness, 20 cm) was irradiated with 170, 290, and 350 AMeV 12C beams using the GATE code. Phantom images of the three types of scanner were evaluated by comparing the longitudinal profile of the positron emitters, measured along the carbon beam as it passed a simulated positron emitter distribution. The results demonstrated that the development of a C-shaped PET scanner to characterize carbon dose distribution for therapy planning is feasible.
Physics of pure and non-pure positron emitters for PET: a review and a discussion.
Conti, Maurizio; Eriksson, Lars
2016-12-01
With the increased interest in new PET tracers, gene-targeted therapy, immunoPET, and theranostics, other radioisotopes will be increasingly used in clinical PET scanners, in addition to (18)F. Some of the most interesting radioisotopes with prospective use in the new fields are not pure short-range β(+) emitters but can be associated with gamma emissions in coincidence with the annihilation radiation (prompt gamma), gamma-gamma cascades, intense Bremsstrahlung radiation, high-energy positrons that may escape out of the patient skin, and high-energy gamma rays that result in some e (+)/e (-) pair production. The high level of sophistication in data correction and excellent quantitative accuracy that has been reached for (18)F in recent years can be questioned by these effects. In this work, we review the physics and the scientific literature and evaluate the effect of these additional phenomena on the PET data for each of a series of radioisotopes: (11)C, (13)N, (15)O, (18)F, (64)Cu, (68)Ga, (76)Br, (82)Rb, (86)Y, (89)Zr, (90)Y, and (124)I. In particular, we discuss the present complications arising from the prompt gammas, and we review the scientific literature on prompt gamma correction. For some of the radioisotopes considered in this work, prompt gamma correction is definitely needed to assure acceptable image quality, and several approaches have been proposed in recent years. Bremsstrahlung photons and (176)Lu background were also evaluated.
Water availability predicts forest canopy height at the global scale.
Klein, Tamir; Randin, Christophe; Körner, Christian
2015-12-01
The tendency of trees to grow taller with increasing water availability is common knowledge. Yet a robust, universal relationship between the spatial distribution of water availability and forest canopy height (H) is lacking. Here, we created a global water availability map by calculating an annual budget as the difference between precipitation (P) and potential evapotranspiration (PET) at a 1-km spatial resolution, and in turn correlated it with a global H map of the same resolution. Across forested areas over the globe, Hmean increased with P-PET, roughly: Hmean (m) = 19.3 + 0.077*(P-PET). Maximum forest canopy height also increased gradually from ~ 5 to ~ 50 m, saturating at ~ 45 m for P-PET > 500 mm. Forests were far from their maximum height potential in cold, boreal regions and in disturbed areas. The strong association between forest height and P-PET provides a useful tool when studying future forest dynamics under climate change, and in quantifying anthropogenic forest disturbance. © 2015 John Wiley & Sons Ltd/CNRS.
Disaster Preparedness for Your Pet
... Diseases Pets Can Transmit to People During a Natural Disaster Natural disasters can contribute to the transmission of some ... Avoid stagnant water, especially after flooding occurring after natural disasters Don’t allow pets to play in ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang, Feng, E-mail: fangfeng@seu.edu.cn; Zhang, Yeyu; Wu, Xiaoqin
2015-08-15
Graphical abstract: The best SnO{sub 2}:N TCO film: about 80% transmittance and 9.1 × 10{sup −4} Ω cm. - Highlights: • Nitrogen-doped tin oxide film was deposited on PET by RF-magnetron sputtering. • Effects of oxygen partial pressure on the properties of thin films were investigated. • For SnO{sub 2}:N film, visible light transmittance was 80% and electrical resistivity was 9.1 × 10{sup −4} Ω cm. - Abstract: Nitrogen-doped tin oxide (SnO{sub 2}:N) thin films were deposited on flexible polyethylene terephthalate (PET) substrates at room temperature by RF-magnetron sputtering. Effects of oxygen partial pressure (0–4%) on electrical and optical propertiesmore » of thin films were investigated. Experimental results showed that SnO{sub 2}:N films were amorphous state, and O/Sn ratios of SnO{sub 2}:N films were deviated from the standard stoichiometry 2:1. Optical band gap of SnO{sub 2}:N films increased from approximately 3.10 eV to 3.42 eV as oxygen partial pressure increased from 0% to 4%. For SnO{sub 2}:N thin films deposited on PET, transmittance was about 80% in the visible light region. The best transparent conductive oxide (TCO) deposited on flexible PET substrates was SnO{sub 2}:N thin films preparing at 2% oxygen partial pressure, the transmittance was about 80% and electrical conductivity was about 9.1 × 10{sup −4} Ω cm.« less
Sources of nitrate in the Arno River waters: Constraints from d15N and d18O
Nisi, Barbara; Vaselli, Orlando; Buccianti, Antonella; Silva, Steven R.
2005-01-01
Running waters in anthropogenically affected areas are susceptible to nitrate contamination. Source identification is a fundamental step for the development of effective remediation. Previous studies pointed to pollution by nitrogen-bearing contaminants in the Arno Basin. In this paper, eleven surface water samples have been analysed for main and trace components and 15N/14N and 18O/16O ratios, with the aim of identifying for the first time the origin of nitrate in the Arno River Basin so that further investigations can appropriately be designed. d18O(NO3)and d15N(NO3) values have allowed to hypothesise the main sources of nitrate, as follows: i) mineralized fertilizer, ii) soil-organic nitrogen, iii) manure and septic waste. The anomalously high d15N and d18O values in the Chiana (d15N=24.9‰ and d18O=15.5‰) and Usciana tributaries (d15N=30.1‰ and d18O=7.2‰) show a low probability of belonging to the same population as that of the other samples and can be related to denitrification process of nitrate from animal waste/sewage and/or an industrial process (e.g. tanneries).
Nitzsche, E U; Choi, Y; Czernin, J; Hoh, C K; Huang, S C; Schelbert, H R
1996-06-01
[13N]Ammonia has been validated in dog studies as a myocardial blood flow tracer. Estimates of myocardial blood flow by [13N]ammonia were highly linearly correlated to those by the microsphere and blood sample techniques. However, estimates of myocardial blood flow with [13N]ammonia in humans have not yet been compared with those by an independent technique. This study therefore tested the hypothesis that the [13N]ammonia positron emission tomographic technique in humans gives estimates of myocardial blood flow comparable to those obtained with the [15O]water technique. A total of 30 pairs of positron emission tomographic flow measurements were performed in 30 healthy volunteers; 15 volunteers were studied at rest and 15 during adenosine-induced hypermia. Estimates of average and of regional myocardial blood flow by the [13N]ammonia and the [15O]water approaches correlated well (y = 0.02 + 1.02x, r = .99, P < .001 SEE = 0.023 for average and y = 0.06 + 1.00x, r = .97, P < .001, SEE = 0.025 for regional values) over a flow range of 0.45 to 4.74 mL.min-1.g-1. At rest, mean myocardial blood flow was 0.64 +/- 0.09 mL.min-1.g-1 for [13N]ammonia and 0.66 +/- 0.12 mL.min-1.g-1 for [15O]water (P = NS). For adenosine-induced hyperemia, mean myocardial blood flow was 2.63 +/- 0.75 mL.min-1.g-1 for [13N]ammonia and 2.73 +/- 0.77 mL.min-1.g-1 for [15O]water (P = NS). The coefficient of variation as an index of the observed heterogeneity of myocardial blood flow averaged, for [13N]ammonia, 9 +/- 4% at rest and 12 +/- 7% during stress and, for [15O]water, 14 +/- 11% at rest and 16 +/- 9% during stress. The coefficients of variation for [15O]water were significantly higher than those for [13N]ammonia (P = .004 at rest and P = .03 during stress). The two approaches yield comparable estimates of myocardial blood flow in humans, which supports the validity of the [13N]ammonia method in human myocardium previously shown only in animals. However, the [15O]water approach reveals a greater heterogeneity (presumably method-related), which might limit the accuracy of sectorial myocardial blood flow estimates in humans.
NASA Astrophysics Data System (ADS)
Hong, Inki; Cho, Sanghee; Michel, Christian J.; Casey, Michael E.; Schaefferkoetter, Joshua D.
2014-09-01
A new data handling method is presented for improving the image noise distribution and reducing bias when reconstructing very short frames from low count dynamic PET acquisition. The new method termed ‘Complementary Frame Reconstruction’ (CFR) involves the indirect formation of a count-limited emission image in a short frame through subtraction of two frames with longer acquisition time, where the short time frame data is excluded from the second long frame data before the reconstruction. This approach can be regarded as an alternative to the AML algorithm recently proposed by Nuyts et al, as a method to reduce the bias for the maximum likelihood expectation maximization (MLEM) reconstruction of count limited data. CFR uses long scan emission data to stabilize the reconstruction and avoids modification of algorithms such as MLEM. The subtraction between two long frame images, naturally allows negative voxel values and significantly reduces bias introduced in the final image. Simulations based on phantom and clinical data were used to evaluate the accuracy of the reconstructed images to represent the true activity distribution. Applicability to determine the arterial input function in human and small animal studies is also explored. In situations with limited count rate, e.g. pediatric applications, gated abdominal, cardiac studies, etc., or when using limited doses of short-lived isotopes such as 15O-water, the proposed method will likely be preferred over independent frame reconstruction to address bias and noise issues.
Tijink, Bernard M; Perk, Lars R; Budde, Marianne; Stigter-van Walsum, Marijke; Visser, Gerard W M; Kloet, Reina W; Dinkelborg, Ludger M; Leemans, C René; Neri, Dario; van Dongen, Guus A M S
2009-08-01
The human monoclonal antibody (MAb) fragment L19-SIP is directed against extra domain B (ED-B) of fibronectin, a marker of tumour angiogenesis. A clinical radioimmunotherapy (RIT) trial with (131)I-L19-SIP was recently started. In the present study, after GMP production of (124)I and efficient production of (124)I-L19-SIP, we aimed to demonstrate the suitability of (124)I-L19-SIP immuno-PET for imaging of angiogenesis at early-stage tumour development and as a scouting procedure prior to clinical (131)I-L19-SIP RIT. (124)I was produced in a GMP compliant way via (124)Te(p,n)(124)I reaction and using a TERIMO module for radioiodine separation. L19-SIP was radioiodinated by using a modified version of the IODO-GEN method. The biodistribution of coinjected (124)I- and (131)I-L19-SIP was compared in FaDu xenograft-bearing nude mice, while (124)I PET images were obtained from mice with tumours of <50 to approximately 700 mm(3). (124)I was produced highly pure with an average yield of 15.4 +/- 0.5 MBq/microAh, while separation yield was approximately 90% efficient with <0.5% loss of TeO(2). Overall labelling efficiency, radiochemical purity and immunoreactive fraction were for (124)I-L19-SIP: approximately 80 , 99.9 and >90%, respectively. Tumour uptake was 7.3 +/- 2.1, 10.8 +/- 1.5, 7.8 +/- 1.4, 5.3 +/- 0.6 and 3.1 +/- 0.4%ID/g at 3, 6, 24, 48 and 72 h p.i., resulting in increased tumour to blood ratios ranging from 6.0 at 24 h to 45.9 at 72 h p.i.. Fully concordant labelling and biodistribution results were obtained with (124)I- and (131)I-L19-SIP. Immuno-PET with (124)I-L19-SIP using a high-resolution research tomograph PET scanner revealed clear delineation of the tumours as small as 50 mm(3) and no adverse uptake in other organs. (124)I-MAb conjugates for clinical immuno-PET can be efficiently produced. Immuno-PET with (124)I-L19-SIP appeared qualified for sensitive imaging of tumour neovasculature and for predicting (131)I-L19-SIP biodistribution.
N2O production by nitrifier denitrification in the Benguela Upwelling System
NASA Astrophysics Data System (ADS)
Frame, C. H.; Hou, L.; Lehmann, M. F.
2014-12-01
The Benguela upwelling system off the coast of southwestern Africa is an important zone of marine N2O production whose upwelling rates vary seasonally. Here we present N2O stable isotopic and isotopomeric data collected during a period of high upwelling (September 2013) and low upwelling (January 2014). During both periods, 15N-nitrite and 15N-ammonium tracer inucbation experiments were used to investigate N2O production by ammonia oxidizing microorganisms in the top 150m of the water column. N2O production from 15N-ammonium was not measurable during these incubations. However, we detected N2O production from 15N-nitrite, suggesting that nitrifier denitrification is a source of shallow N2O in this region. Furthermore, decreasing the pH of the incubation water enhanced the amount of N2O produced, suggesting that upwelling of CO2-rich/low-pH deep water may enhance N2O production in this region. Finally, we present our incubation data in the larger context of the N2O and nitrite isotopic and concentration profiles, with an eye toward comparing incubation-based N2O production rates with profile-based estimates.
Electron-stimulated reactions in nanoscale water films adsorbed on (alpha)-Al2O3(0001)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrik, Nikolay G.; Kimmel, Gregory A.
2018-05-11
The radiation-induced decomposition and desorption of nanoscale amorphous solid water (D2O) films adsorbed on -Al2O3(0001) surface was studied at low temperature in ultrahigh vacuum using temperature programmed desorption (TPD) and electron stimulated desorption (ESD) with a mono-energetic, low energy electron source. ESD yields of molecular products ( D2, O2 and D¬2O) and the total sputtering yield increased with increasing D2O coverage up to ~15 water monolayers (i.e. ~15 1015 cm-2) to a coverage-independent level for thicker water films. Experiments with isotopically-layered water films (D2O and H2O) demonstrated that the highest water decomposition yields occurred at the interfaces of the nanoscalemore » water films with the alumina substrate and vacuum. However, the increased reactivity of the water/alumina interface is relatively small compared to the enhancements in the non-thermal reactions previously observed at the water/Pt(111) and water/TiO2(110) interfaces. We propose that the relatively low activity of Al2O3(0001) for the radiation-induced production of molecular hydrogen is associated with lower reactivity of this surface with hydrogen atoms, which are likely precursors for the molecular hydrogen.« less
Shoemaker, W. Barclay; Sumner, D.M.
2006-01-01
Corrections can be used to estimate actual wetland evapotranspiration (AET) from potential evapotranspiration (PET) as a means to define the hydrology of wetland areas. Many alternate parameterizations for correction coefficients for three PET equations are presented, covering a wide range of possible data-availability scenarios. At nine sites in the wetland Everglades of south Florida, USA, the relatively complex PET Penman equation was corrected to daily total AET with smaller standard errors than the PET simple and Priestley-Taylor equations. The simpler equations, however, required less data (and thus less funding for instrumentation), with the possibility of being corrected to AET with slightly larger, comparable, or even smaller standard errors. Air temperature generally corrected PET simple most effectively to wetland AET, while wetland stage and humidity generally corrected PET Priestley-Taylor and Penman most effectively to wetland AET. Stage was identified for PET Priestley-Taylor and Penman as the data type with the most correction ability at sites that are dry part of each year or dry part of some years. Finally, although surface water generally was readily available at each monitoring site, AET was not occurring at potential rates, as conceptually expected under well-watered conditions. Apparently, factors other than water availability, such as atmospheric and stomata resistances to vapor transport, also were limiting the PET rate. ?? 2006, The Society of Wetland Scientists.
Gómez-Couso, H; Fontán-Sainz, M; Navntoft, C; Fernández-Ibáñez, P; Ares-Mazás, E
2012-11-01
Solar water disinfection (SODIS) is a type of treatment that can significantly improve the microbiological quality of drinking water at household level and therefore prevent waterborne diseases in developing countries. Cryptosporidium parvum is an obligate protozoan parasite responsible for the diarrhoeal disease cryptosporidiosis in humans and animals. Recently, this parasite has been selected by the WHO as a reference pathogen for protozoan parasites in the evaluation of household water treatment options. In this study, the field efficacy of different static solar reactors [1.5 l transparent plastic polyethylene terephthalate (PET) bottles as well as 2.5 l borosilicate glass and 25 l methacrylate reactors fitted with compound parabolic concentrators (CPC)] for solar disinfection of turbid waters experimentally contaminated with C. parvum oocysts was compared. Potential oocyst viability was determined by inclusion/exclusion of the fluorogenic vital dye propidium iodide. The results demonstrate that static solar reactors fitted with CPCs are an excellent alternative to the conventional SODIS method with PET bottles. These reactors improved the efficacy of the SODIS method by enabling larger volumes of water to be treated and, in some cases, the C. parvum oocysts were rendered totally unviable, minimising the negative effects of turbidity. Copyright © 2012 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Khoirunnisa, Assifa Rahma; Joni, I. Made; Panatarani, Camellia; Rochima, Emma; Praseptiangga, Danar
2018-02-01
This study aims to develop film for food packaging application with high UV-screening, transparency and water barrier properties. Semi refined iota carrageenan (SRiC) nanocomposite films prepared by addition of zinc oxide (ZnO) nanoparticles as nanofiller using solution casting method. The effect of nanofiller with different concentration (0%, 0.5%, 1.0%, 1.5% w/w carrageenan) on UV-screening, transparency and water barrier properties of films were tested. The water barrier properties of the films were studied by measuring water vapor permeability (WVP) and the optical properties of the films were studied by using UV-Vis spectrophotometer at 280 nm for UV-screening test and at 660 nm for transparency test. WVP value of carrageenan films with addition of ZnO is low compared to a control carrageenan film and the lowest WVP value was found for the film with addition of 1.5% of ZnO. These result indicate that the addition of ZnO had a positive effect on the water barrier properties of the carrageenan matrix. Increase in the concentration of nanofiller leads to an increase in the UV-screening properties. Among all the films, carrageenan film with 1.5% ZnO has the highest UV-screening. The result showed that adding 0.5% and 1.0% of ZnO was insignificantly affect transparency of the films, however the transparency decreased sligthly when 1.5% ZnO was added. In conclusion, incorporating no more than 1.0% of ZnO to the films can obtain films with high UV-screening, transparency and water barrier properties and suitable for food packaging application.
Mo and P co-doped Ba5Ta4O15 for hydrogen evolution under solar light
NASA Astrophysics Data System (ADS)
Li, Songjie; Cao, Wenbo; Wang, Chengduo; Du, Xueshan; Lu, Shufen
2018-07-01
Based on density functional calculations, Mo and P co-doped Ba5Ta4O15 compared with their mono-doping was studied for splitting water. The results showed that Mo-P co-doping significantly reduced the energy gap of Ba5Ta4O15 from 4.05 eV to 2.15 eV, being almost the optimum value for utilizing solar energy as much as possible. The top of valence band and the bottom of conduction band are both compatible with the oxidation-reduction potentials of water. More importantly, Mo-P co-doping prevents the filled spin-down states of Mo and the empty spin-down states of P from arising due to the charge compensation of Mo-P pairs. We propose that Mo-P co-doped Ba5Ta4O15 is one of the most promising photocatalyst candidates for solar water splitting.
Development of a MPPC-based prototype gantry for future MRI-PET scanners
NASA Astrophysics Data System (ADS)
Kurei, Y.; Kataoka, J.; Kato, T.; Fujita, T.; Ohshima, T.; Taya, T.; Yamamoto, S.
2014-12-01
We have developed a high spatial resolution, compact Positron Emission Tomography (PET) module designed for small animals and intended for use in magnetic resonance imaging (MRI) systems. This module consists of large-area, 4 × 4 ch MPPC arrays (S11830-3344MF; Hamamatsu Photonics K.K.) optically coupled with Ce-doped (Lu,Y)2(SiO4)O (Ce:LYSO) scintillators fabricated into 16 × 16 matrices of 0.5 × 0.5 mm2 pixels. We set the temperature sensor (LM73CIMK-0; National Semiconductor Corp.) at the rear of the MPPC acceptance surface, and apply optimum voltage to maintain the gain. The eight MPPC-based PET modules and coincidence circuits were assembled into a gantry arranged in a ring 90 mm in diameter to form the MPPC-based PET system. We have developed two types PET gantry: one made of non-magnetic metal and the other made of acrylonitrile butadiene styrene (ABS) resins. The PET gantry was positioned around the RF coil of the 4.7 T MRI system. We took an image of a point }22Na source under fast spin echo (FSE) and gradient echo (GE), in order to measure the interference between the MPPC-based PET and MRI. The spatial resolution of PET imaging in a transaxial plane of about 1 mm (FWHM) was achieved in all cases. Operating with PET made of ABS has no effect on MR images, while operating with PET made of non-magnetic metal has a significant detrimental effect on MR images. This paper describes our quantitative evaluations of PET images and MR images, and presents a more advanced version of the gantry for future MRI/DOI-PET systems.
Performance evaluation for 120 four-layer DOI block detectors of the jPET-D4.
Inadama, Naoko; Murayama, Hideo; Ono, Yusuke; Tsuda, Tomoaki; Hamamoto, Manabu; Yamaya, Taiga; Yoshida, Eiji; Shibuya, Kengo; Nishikido, Fumihiko; Takahashi, Kei; Kawai, Hideyuki
2008-01-01
The jPET-D4 is a brain positron emission tomography (PET) scanner that we have developed to meet user demands for high sensitivity and high spatial resolution. For this scanner, we developed a four-layer depth-of-interaction (DOI) detector. The four-layer DOI detector is a key component for the jPET-D4, its performance has great influence on the overall system performance. Previously, we reported the original technique for encoding four-layer DOI. Here, we introduce the final design of the jPET-D4 detector and present the results of an investigation on uniformity in performance of the detector. The performance evaluation was done over the 120 DOI crystal blocks for the detectors, which are to be assembled into the jPET-D4 scanner. We also introduce the crystal assembly method, which is simple enough, even though each DOI crystal block is composed of 1,024 crystal elements. The jPET-D4 detector consists of four layers of 16 x 16 Gd(2)SiO(5) (GSO) crystals and a 256-channel flat-panel position-sensitive photomultiplier tube (256ch FP-PMT). To identify scintillated crystals in the four-layer DOI detector, we use pulse shape discrimination and position discrimination on the two-dimensional (2D) position histogram. For pulse shape discrimination, two kinds of GSO crystals that show different scintillation decay time constants are used in the upper two and lower two layers, respectively. Proper reflector arrangement in the crystal block then allows the scintillated crystals to be identified in these two-layer groupings with two 2D position histograms. We produced the 120 DOI crystal blocks for the jPET-D4 system, and measured their characteristics such as the accuracy of pulse shape discrimination, energy resolution, and the pulse height of the full energy peak. The results show a satisfactory and uniform performance of the four-layer DOI crystal blocks; for example, misidentification rate in each GSO layer is <5% based on pulse shape discrimination, the averaged energy resolutions for the central four crystals of the first (farthest from the FP-PMT), second, third, and 4th layers are 15.7 +/- 1.0, 15.8 +/- 0.6, 17.7 +/- 1.2, and 17.3 +/- 1.4%, respectively, and variation in pulse height of the full energy peak among the four layers is <5% on average.
NASA Astrophysics Data System (ADS)
Ahmad, A. F.; Razali, A. R.; Razelan, I. S. M.; Jalil, S. S. A.; Noh, M. S. M.; Idris, A. A.
2017-05-01
Plastic bottle for recycling can be found from the household waste stream, and most of them are made from Polyethylene Terephthalate. In this research, PET is utilized to explore the potential prospects to upgrade asphalt mixture properties. The objectives include deciding the best measure of PET to be used. For experimental, Marshall mix design was utilized to determine the ideal bitumen binder content and to test the modified mixture properties. The samples were created per the requirement for aggregate course wearing (ACW14) using the Standard Specification of Road Work (SSRW) in Malaysia. 20 samples were utilized to determine the binder content, and 30 samples were used to research the impact of modifying asphalt mixtures. 2%, 5%, 10%, 15% and 20% of PET by weight of the optimum binder content (4.8%) were tested. Optimum PET content is 10%, and the result shows a good stability with 16.824kN, 2.32g/cm3 bulk density, void filled with bitumen (VFB) with 71.35%, flow with 3.2248mm, air void (AV) with 4.53%, and void of mineral aggregate (VMA) with 15.15%. The outcomes showed that PET modifier gives better engineering properties. Therefore, 10% of PET by the weight of binder content was suggested as the best amount of the modifier.
Monte Carlo investigation of positron annihilation in medical positron emission tomography
NASA Astrophysics Data System (ADS)
Chin, P. W.; Spyrou, N. M.
2007-09-01
A number of Monte Carlo codes are available for simulating positron emission tomography (PET), however, physics approximations differ. A number of radiation processes are deemed negligible, some without rigorous investigation. Some PET literature quantify approximations to be valid, without citing the data source. The radiation source is the first step in Monte Carlo simulations, for some codes this is 511 keV photons 180° apart, not polyenergetic positrons with radiation histories of their own. Without prior assumptions, we investigated electron-positron annihilation under clinical PET conditions. Just before annihilation, we tallied the positron energy and position. Right after annihilation, we tallied the energy and separation angle of photon pairs. When comparing PET textbooks with theory, PENELOPE and EGSnrc, only the latter three agreed. From 10 6 radiation histories, a positron source of 15O in a chest phantom annihilated at as high as 1.58 MeV, producing photons with energies 0.30-2.20 MeV, 79-180° apart. From 10 6 radiation histories, an 18F positron source in a head phantom annihilated at energies as high as 0.56 MeV, producing 0.33-1.18 MeV photons 109-180° apart. 2.5% and 0.8% annihilation events occurred inflight in the chest and the head phantoms, respectively. PET textbooks typically either do not mention any deviation from 180°, or state a deviation of 0.25° or 0.5°. Our findings are founded on the well-established Heitler cross-sections and relativistic kinematics, both adopted unanimously by PENELOPE, EGSnrc and GEANT4. Our results highlight the effects of annihilation in-flight, a process sometimes forgotten within the PET community.
NASA Astrophysics Data System (ADS)
Belinato, Walmir; Santos, William S.; Perini, Ana P.; Neves, Lucio P.; Caldas, Linda V. E.; Souza, Divanizia N.
2017-11-01
Positron emission tomography (PET) has revolutionized the diagnosis of cancer since its conception. When combined with computed tomography (CT), PET/CT performed in children produces highly accurate diagnoses from images of regions affected by malignant tumors. Considering the high risk to children when exposed to ionizing radiation, a dosimetric study for PET/CT procedures is necessary. Specific absorbed fractions (SAF) were determined for monoenergetic photons and positrons, as well as the S-values for six positron emitting radionuclides (11C, 13N, 18F, 68Ga, 82Rb, 15O), and 22 source organs. The study was performed for six pediatric anthropomorphic hybrid models, including the newborn and 1 year hermaphrodite, 5 and 10-year-old male and female, using the Monte Carlo N-Particle eXtended code (MCNPX, version 2.7.0). The results of the SAF in source organs and S-values for all organs showed to be inversely related to the age of the phantoms, which includes the variation of body weight. The results also showed that radionuclides with higher energy peak emission produces larger auto absorbed S-values due to local dose deposition by positron decay. The S-values for the source organs are considerably larger due to the interaction of tissue with non-penetrating particles (electrons and positrons) and present a linear relationship with the phantom body masses. The results of the S-values determined for positron-emitting radionuclides can be used to assess the radiation dose delivered to pediatric patients subjected to PET examination in clinical settings. The novelty of this work is associated with the determination of auto absorbed S-values, in six new pediatric virtual anthropomorphic phantoms, for six emitting positrons, commonly employed in PET exams.
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
PET fiber fabrics modified with bioactive titanium oxide for bone substitutes.
Kokubo, Tadashi; Ueda, Takahiro; Kawashita, Masakazu; Ikuhara, Yuichi; Takaoka, Gikan H; Nakamura, Takashi
2008-02-01
A rectangular specimen of polyethylene terephthalate (PET) was soaked in a titania solution composed of titanium isopropoxide, water, ethanol and nitric acid at 25 degrees C for 1 h. An amorphous titanium oxide was formed uniformly on the surface of PET specimen, but did not form an apatite on its surface in a simulated body fluid (SBF) within 3 d. The PET plate formed with the amorphous titanium oxide was subsequently soaked in water or HCl solutions with different concentrations at 80 degrees C for different periods of time. The titanium oxide on PET was transformed into nano-sized anatase by the water treatment and into nano-sized brookite by 0.10 M HCl treatment at 80 degrees C for 8 d. The former did not form the apatite on its surface in SBF within 3 d, whereas the latter formed the apatite uniformly on its surface. Adhesive strength of the titanium oxide and apatite layers to PET plate was increased by pre-treatment of PET with 2 wt% NaOH solution at 40 degrees C for 2 h. A two-dimensional fabric of PET fibers 24 microm in diameter was subjected to the NaOH pre-treatment at 40 degrees C, titania solution treatment at 25 degrees C and subsequent 0.10 M HCl treatment at 80 degrees C. Thus treated PET fabric formed the apatite uniformly on surfaces of individual fibers constituting the fabric in SBF within 3 d. Two or three dimensional PET fabrics modified with the nano-sized brookite on surfaces of the individual fibers constituting the fabric by the present method are believed to be useful as flexible bone substitutes, since they could be integrated with living bone through the apatite formed on their constituent fibers.
Gupta, Nidhi; Yadav, Tushar
2018-04-16
To evaluate the parents' acceptance to therapy pets, child's most favoured pet, child's choice of soft toy as compared to live pet, and child's preference of his own pet versus therapy pet. Sixty-two children of age groups 3-6 year, 6-9 year, and 9-12 year were selected. The data from completed questionnaires were statistically analysed and subjected to z test, Chi-squared test with P value<0.05 considered as significant. The consent to the presence of pet was given by 41.47% parents of 9- to 12-year-old children, 34.15% parents of 6- to 9-year-old children and 24.39% parents of 3- to 6-year-old children. Children who chose dog as their preferred pet were 56.7%; those who chose cat as their preferred pet were 44%. A majority of 3-to 6-year-olds (63.15%) had dog & cat as their choice, while 6- to 9-year-olds (65.21%) & 9- to 12-year-olds (40%) preferred dogs over all others. Dog was the favourite pet of 46.8% children. More percentage of children wanted pet provided by clinic. Animal-Assisted Therapy (AAT) can prove to be a good behaviour management technique if more parents are made aware and informed about AAT; dog is one of the highly recommended pets for AAT, and therapy pet should be preferred over home pet. © 2018 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Temporal and spatial variability of global water balance
McCabe, Gregory J.; Wolock, David M.
2013-01-01
An analysis of simulated global water-balance components (precipitation [P], actual evapotranspiration [AET], runoff [R], and potential evapotranspiration [PET]) for the past century indicates that P has been the primary driver of variability in R. Additionally, since about 2000, there have been increases in P, AET, R, and PET for most of the globe. The increases in R during 2000 through 2009 have occurred despite unprecedented increases in PET. The increases in R are the result of substantial increases in P during the cool Northern Hemisphere months (i.e. October through March) when PET increases were relatively small; the largest PET increases occurred during the warm Northern Hemisphere months (April through September). Additionally, for the 2000 through 2009 period, the latitudinal distribution of P departures appears to co-vary with the mean P departures from 16 climate model projections of the latitudinal response of P to warming, except in the high latitudes. Finally, changes in water-balance variables appear large from the perspective of departures from the long-term means. However, when put into the context of the magnitudes of the raw water balance variable values, there appears to have been little change in any of the water-balance variables over the past century on a global or hemispheric scale.
Fabrication and performance of PET mesh enhanced cellulose acetate membranes for forward osmosis.
Li, Guoliang; Wang, Jun; Hou, Deyin; Bai, Yu; Liu, Huijuan
2016-07-01
Polyethylene terephthalate mesh (PET) enhanced cellulose acetate membranes were fabricated via a phase inversion process. The membrane fabrication parameters that may affect the membrane performance were systematically evaluated including the concentration and temperature of the casting polymer solution and the temperature and time of the evaporation, coagulation and annealing processes. The water permeability and reverse salt flux were measured in forward osmosis (FO) mode for determination of the optimal membrane fabrication conditions. The optimal FO membrane shows a typical asymmetric sandwich structure with a mean thickness of about 148.2μm. The performance of the optimal FO membrane was tested using 0.2mol/L NaCl as the feed solution and 1.5mol/L glucose as the draw solution. The membrane displayed a water flux of 3.47L/(m(2)·hr) and salt rejection of 95.48% in FO mode. While in pressure retarded osmosis (PRO) mode, the water flux was 4.74L/(m(2)·hr) and salt rejection 96.03%. The high ratio of water flux in FO mode to that in PRO mode indicates that the fabricated membrane has a lower degree of internal concentration polarization than comparable membranes. Copyright © 2016. Published by Elsevier B.V.
Schmidt, Horst; Hennings, Erik; Voigt, Wolfgang
2014-09-01
Water-rich aluminium halide hydrate structures are not known in the literature. The highest known water content per Al atom is nine for the perchlorate and fluoride. The nonahydrate of aluminium bromide, stable pentadecahydrates of aluminium chloride, bromide and iodide, and a metastable heptadecahydrate of the iodide have now been crystallized from low-temperature solutions. The structures of these hydrates were determined and are discussed in terms of the development of cation hydration spheres. The pentadecahydrate of the chloride and bromide are isostructural. In AlI(3) · 15H2O, half of the Al(3+) cations are surrounded by two complete hydration spheres, with six H2O in the primary and 12 in the secondary. For the heptadecahydrate of aluminium iodide, this hydration was found for every Al(3+).
Antimony leaching from polyethylene terephthalate (PET) plastic used for bottled drinking water.
Westerhoff, Paul; Prapaipong, Panjai; Shock, Everett; Hillaireau, Alice
2008-02-01
Antimony is a regulated contaminant that poses both acute and chronic health effects in drinking water. Previous reports suggest that polyethylene terephthalate (PET) plastics used for water bottles in Europe and Canada leach antimony, but no studies on bottled water in the United States have previously been conducted. Nine commercially available bottled waters in the southwestern US (Arizona) were purchased and tested for antimony concentrations as well as for potential antimony release by the plastics that compose the bottles. The southwestern US was chosen for the study because of its high consumption of bottled water and elevated temperatures, which could increase antimony leaching from PET plastics. Antimony concentrations in the bottled waters ranged from 0.095 to 0.521 ppb, well below the US Environmental Protection Agency (USEPA) maximum contaminant level (MCL) of 6 ppb. The average concentration was 0.195+/-0.116 ppb at the beginning of the study and 0.226+/-0.160 ppb 3 months later, with no statistical differences; samples were stored at 22 degrees C. However, storage at higher temperatures had a significant effect on the time-dependent release of antimony. The rate of antimony (Sb) release could be fit by a power function model (Sb(t)=Sb 0 x[Time, h]k; k=8.7 x 10(-6)x[Temperature ( degrees C)](2.55); Sb 0 is the initial antimony concentration). For exposure temperatures of 60, 65, 70, 75, 80, and 85 degrees C, the exposure durations necessary to exceed the 6 ppb MCL are 176, 38, 12, 4.7, 2.3, and 1.3 days, respectively. Summertime temperatures inside of cars, garages, and enclosed storage areas can exceed 65 degrees C in Arizona, and thus could promote antimony leaching from PET bottled waters. Microwave digestion revealed that the PET plastic used by one brand contained 213+/-35 mgSb/kg plastic; leaching of all the antimony from this plastic into 0.5L of water in a bottle could result in an antimony concentration of 376 ppb. Clearly, only a small fraction of the antimony in PET plastic bottles is released into the water. Still, the use of alternative types of plastics that do not leach antimony should be considered, especially for climates where exposure to extreme conditions can promote antimony release from PET plastics.
Breault, Tanya M; Brancho, James J; Guo, Ping; Bartlett, Bart M
2013-08-19
The photocatalytic activity of anatase-structured Ti(1-(5x/4))Nb(x)O(2-y-δ)N(y) (x = 0.25, y = 0.02; NbN-25) was examined for water oxidation under UV and visible light irradiation. The semiconductor was prepared by sol-gel processing followed by nitridation in flowing ammonia and exhibits an indirect optical gap of 2.2 eV. Ti(1-(5x/4))Nb(x)O(2-y-δ)N(y) was loaded with RuO2 by an impregnation technique, and optimized conditions reveal that 1 wt % RuO2 generates 16 μmol O2 from water with concomitant IO3(-) reduction after 3 h of illumination under simulated solar radiation at a flux of 600 mW/cm(2) illumination, which corresponds to 6-sun AM1.5G illumination (compared to no detectible O2 without the RuO2 cocatalyst). A series of cut-on filters shows that the catalyst-loaded semiconductor evolves O2 for λ ≤ 515 nm, and a gas-phase mass spectrometry isotope labeling experiment shows that irradiating an iodate solution in H2(18)O in the presence of 1 wt % RuO2 loaded on NbN-25 gives rise to catalytic water oxidation: both (36)O2 and (34)O2 are observed. It is unclear whether (16)O arises from IO3(-) or surface reconstruction on the photocatalyst, but ICP-AES analysis of the postirradiated solution shows no dissolved metal ions.
Widén, H; Leufvén, A; Nielsen, T
2005-07-01
Mineral water and soft drinks with a perceptible off-odour were analysed to identify contaminants originating from previous misuse of the refillable polyethylene terephthalate (PET) bottle. Consumers detected the off-odour after opening the bottle and duly returned it with the remaining content to the producers. The contaminants in question had thus been undetected by the in-line detection devices (so-called 'sniffers') that are supposed to reject misused bottles. GC-MS analysis was carried out on the headspace of 31 returned products and their corresponding reference products, and chromatograms were compared to find the possible off-odour compounds. Substances believed to be responsible for the organoleptic change were 2-methoxynaphthalene (10 bottles), dimethyl disulfide (4), anethole (3), petroleum products (4), ethanol with isoamyl alcohol (1) and a series of ethers (1). The mouldy/musty odour (5 bottles) was caused by trichloroanisole in one instance. In some cases, the origins of the off-odours are believed to be previous consumer misuse of food products (liquorice-flavoured alcohol, home-made alcohol containing fusel oil) or non-food products (cleaning products, petroleum products, oral moist snuff and others). The results also apply to 1.5-litre recyclable PET bottles, since the nature and extent of consumer misuse can be expected to be similar for the two bottle types.
Alternative Dietary Fiber Sources in Companion Animal Nutrition
de Godoy, Maria R. C.; Kerr, Katherine R.; Fahey, George C.
2013-01-01
The US has a pet population of approximately 70 million dogs and 74 million cats. Humans have developed a strong emotional bond with companion animals. As a consequence, pet owners seek ways to improve health, quality of life and longevity of their pets. Advances in canine and feline nutrition have contributed to improved longevity and well-being. Dietary fibers have gained renewed interest in the pet food industry, due to their important role in affecting laxation and stool quality. More recently, because of increased awareness of the beneficial effects of dietary fibers in health, as well as the popularity of functional foods and holistic and natural diets, alternative and novel carbohydrates have become widespread in human and pet nutrition. Fiber sources from cereal grains, whole grains and fruits have received increasing attention by the pet food industry and pet owners. While limited scientific information is available on the nutritional and nutraceutical properties of alternative fiber sources, studies indicate that corn fiber is an efficacious fiber source for pets, showing no detrimental effects on palatability or nutrient digestibility, while lowering the glycemic response in adult dogs. Fruit fiber and pomaces have good water-binding properties, which may be advantageous in wet pet food production, where a greater water content is required, along with low water activity and a firm texture of the final product. Rice bran is a palatable fiber source for dogs and may be an economical alternative to prebiotic supplementation of pet foods. However, it increases the dietary requirement of taurine in cats. Barley up to 40% in a dry extruded diet is well tolerated by adult dogs. In addition, consumption of complex carbohydrates has shown a protective effect on cardiovascular disease and oxidative stress. Alternative fiber sources are suitable ingredients for pet foods. They have been shown to be nutritionally adequate and to have potential nutraceutical properties. PMID:23925042
Alternative dietary fiber sources in companion animal nutrition.
de Godoy, Maria R C; Kerr, Katherine R; Fahey, George C
2013-08-06
The US has a pet population of approximately 70 million dogs and 74 million cats. Humans have developed a strong emotional bond with companion animals. As a consequence, pet owners seek ways to improve health, quality of life and longevity of their pets. Advances in canine and feline nutrition have contributed to improved longevity and well-being. Dietary fibers have gained renewed interest in the pet food industry, due to their important role in affecting laxation and stool quality. More recently, because of increased awareness of the beneficial effects of dietary fibers in health, as well as the popularity of functional foods and holistic and natural diets, alternative and novel carbohydrates have become widespread in human and pet nutrition. Fiber sources from cereal grains, whole grains and fruits have received increasing attention by the pet food industry and pet owners. While limited scientific information is available on the nutritional and nutraceutical properties of alternative fiber sources, studies indicate that corn fiber is an efficacious fiber source for pets, showing no detrimental effects on palatability or nutrient digestibility, while lowering the glycemic response in adult dogs. Fruit fiber and pomaces have good water-binding properties, which may be advantageous in wet pet food production, where a greater water content is required, along with low water activity and a firm texture of the final product. Rice bran is a palatable fiber source for dogs and may be an economical alternative to prebiotic supplementation of pet foods. However, it increases the dietary requirement of taurine in cats. Barley up to 40% in a dry extruded diet is well tolerated by adult dogs. In addition, consumption of complex carbohydrates has shown a protective effect on cardiovascular disease and oxidative stress. Alternative fiber sources are suitable ingredients for pet foods. They have been shown to be nutritionally adequate and to have potential nutraceutical properties.
Application of calibrated fMRI in Alzheimer's disease.
Lajoie, Isabelle; Nugent, Scott; Debacker, Clément; Dyson, Kenneth; Tancredi, Felipe B; Badhwar, AmanPreet; Belleville, Sylvie; Deschaintre, Yan; Bellec, Pierre; Doyon, Julien; Bocti, Christian; Gauthier, Serge; Arnold, Douglas; Kergoat, Marie-Jeanne; Chertkow, Howard; Monchi, Oury; Hoge, Richard D
2017-01-01
Calibrated fMRI based on arterial spin-labeling (ASL) and blood oxygen-dependent contrast (BOLD), combined with periods of hypercapnia and hyperoxia, can provide information on cerebrovascular reactivity (CVR), resting blood flow (CBF), oxygen extraction fraction (OEF), and resting oxidative metabolism (CMRO 2 ). Vascular and metabolic integrity are believed to be affected in Alzheimer's disease (AD), thus, the use of calibrated fMRI in AD may help understand the disease and monitor therapeutic responses in future clinical trials. In the present work, we applied a calibrated fMRI approach referred to as Quantitative O2 (QUO2) in a cohort of probable AD dementia and age-matched control participants. The resulting CBF, OEF and CMRO 2 values fell within the range from previous studies using positron emission tomography (PET) with 15 O labeling. Moreover, the typical parietotemporal pattern of hypoperfusion and hypometabolism in AD was observed, especially in the precuneus, a particularly vulnerable region. We detected no deficit in frontal CBF, nor in whole grey matter CVR, which supports the hypothesis that the effects observed were associated specifically with AD rather than generalized vascular disease. Some key pitfalls affecting both ASL and BOLD methods were encountered, such as prolonged arterial transit times (particularly in the occipital lobe), the presence of susceptibility artifacts obscuring medial temporal regions, and the challenges associated with the hypercapnic manipulation in AD patients and elderly participants. The present results are encouraging and demonstrate the promise of calibrated fMRI measurements as potential biomarkers in AD. Although CMRO 2 can be imaged with 15 O PET, the QUO2 method uses more widely available imaging infrastructure, avoids exposure to ionizing radiation, and integrates with other MRI-based measures of brain structure and function.
Sato, Jun; Kitagawa, Yoshimasa; Yamazaki, Yutaka; Hata, Hironobu; Asaka, Takuya; Miyakoshi, Masaaki; Okamoto, Shozo; Shiga, Tohru; Shindoh, Masanobu; Kuge, Yuji; Tamaki, Nagara
2014-11-01
Hypoxia, a prognostic factor in many types of cancer, can be detected by (18)F-fluoromisonidazole (FMISO) positron emission tomography (PET). It is unclear whether hypoxia reflects the response to chemotherapy in patients with oral squamous cell carcinoma (OSCC). The correlations of FMISO-PET and FDG-PET with histological response to preoperative chemotherapy were therefore assessed in patients with OSCC. This study enrolled 22 patients with OSCC undergoing preoperative chemotherapy. The T-stages were T2 in 6 patients, T3 in 3, and T4a in 13, and the N-stages were N0 in 14 patients, N1 in 3, and N2 in 5. Each patient was evaluated by both FMISO-PET and FDG-PET before surgery, and the maximum standardized uptake value (SUVmax) of FDG- and FMISO-PET and tumor-muscle ratio (TMR) of FMISO-PET were measured. The threshold for the hypoxic volume based on TMR was set at 1.25. The histological response to preoperative chemotherapy was evaluated using operative materials. FMISO-PET and FDG-PET detected uptake by primary OSCCs in 15 (68%) and 21 (95%) patients, respectively, and median SUVmaxs of FMISO- and FDG-PET in the primary site were 2.0 (range, 1.3-3.5) and 16.0 (range, 1.0-32.2), respectively. The median of FMISO TMR was 1.5 (range, 0.99-2.96). There were five cases whose FMISO TMR was less than 1.25. Histological evaluation showed good response to preoperative chemotherapy in 7 patients (32%) and poor response in 15 (68%). Good response was significantly more prevalent in patients with negative than positive FMISO uptake (P < 0.001) and without the hypoxic area evaluated by FMISO-PET TMR (P = 0.04), whereas FDG uptake was not significantly correlated with response to chemotherapy response. Multivariate logistic regression analysis showed that FMISO uptake was an independent significant predictor of response to preoperative chemotherapy (P = 0.03, odds ratio = 0.06, 95% confidence interval = 0.004-0.759). An advantage of FMISO-PET over FDG-PET for predicting histological response to preoperative chemotherapy in patients with OSCC was observed.
de Blois, Erik; Chan, Ho Sze; Roy, Kamalika; Krenning, Eric P; Breeman, Wouter A P
PET with 68 Ga from the TiO 2 - or SnO 2 - based 68 Ge/ 68 Ga generators is of increasing interest for PET imaging in nuclear medicine. In general, radionuclidic purity ( 68 Ge vs. 68 Ga activity) of the eluate of these generators varies between 0.01 and 0.001%. Liquid waste containing low amounts of 68 Ge activity is produced by eluting the 68 Ge/ 68 Ga generators and residues from PET chemistry. Since clearance level of 68 Ge activity in waste may not exceed 10 Bq/g, as stated by European Directive 96/29/EURATOM, our purpose was to reduce 68 Ge activity in solution from >10 kBq/g to <10 Bq/g; which implies the solution can be discarded as regular waste. Most efficient method to reduce the 68 Ge activity is by sorption of TiO 2 or Fe 2 O 3 and subsequent centrifugation. The required 10 Bq per mL level of 68 Ge activity in waste was reached by Fe 2 O 3 logarithmically, whereas with TiO 2 asymptotically. The procedure with Fe 2 O 3 eliminates ≥90% of the 68 Ge activity per treatment. Eventually, to simplify the processing a recirculation system was used to investigate 68 Ge activity sorption on TiO 2 , Fe 2 O 3 or Zeolite. Zeolite was introduced for its high sorption at low pH, therefore 68 Ge activity containing waste could directly be used without further interventions. 68 Ge activity containing liquid waste at different HCl concentrations (0.05-1.0 M HCl), was recirculated at 1 mL/min. With Zeolite in the recirculation system, 68 Ge activity showed highest sorption.
Self-powered p-NiO/n-ZnO heterojunction ultraviolet photodetectors fabricated on plastic substrates
Hasan, Md Rezaul; Xie, Ting; Barron, Sara C.; Liu, Guannan; Nguyen, Nhan V.; Motayed, Abhishek; Rao, Mulpuri V.; Debnath, Ratan
2016-01-01
A self-powered ultraviolet (UV) photodetector (PD) based on p-NiO and n-ZnO was fabricated using low-temperature sputtering technique on indium doped tin oxide (ITO) coated plastic polyethylene terephthalate (PET) substrates. The p-n heterojunction showed very fast temporal photoresponse with excellent quantum efficiency of over 63% under UV illumination at an applied reverse bias of 1.2 V. The engineered ultrathin Ti/Au top metal contacts and UV transparent PET/ITO substrates allowed the PDs to be illuminated through either front or back side. Morphology, structural, chemical and optical properties of sputtered NiO and ZnO films were also investigated. PMID:26900532
Radhakrishnan, Renjith K; Mittal, Bhagwant R; Basher, Rajender K; Prakash, Gaurav; Malhotra, Pankaj; Kalra, Naveen; Das, Ashim
2018-01-01
The aim of this study was to analyse the positive predictive value (PPV) of post-therapy fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT performed for response or recurrence evaluation in patients with non-Hodgkin's lymphoma (NHL) and to appraise the diagnostic utility of F-FDG PET/CT-guided biopsy in this setting. A total of 17 patients with NHL showing F-FDG avid lesions in F-FDG PET/CT performed for response or recurrence assessment underwent F-FDG PET/CT-guided biopsy using automated robotic biopsy arm needle navigation technique. The objectives were analysed in reference to histopathology. In all, 15 of the 17 (88.5%) procedures yielded adequate representative tissue samples. Nine out of 15 lesions were positive for residual disease and the remaining revealed benign findings on histopathology. One patient with inconclusive biopsy underwent surgical resection and histopathology confirmed the presence of residual disease. PPV of theF-FDG PET/CT was observed to be 62.5% (10/16). F-FDG PET/CT for response evaluation in NHL possesses a low PPV and hence warrants histopathological correlation when F-FDG PET/CT findings influence management decision. Diagnostic yield of F-FDG PET/CT-guided biopsy is high and has the potential to reduce sampling errors.
Ikeda, Ryoukichi; Kikuchi, Toshiaki; Miyazaki, Hiromitsu; Hidaka, Hiroshi; Kawase, Tetsuaki; Katori, Yukio; Kobayashi, Toshimitsu
2018-01-01
To assess the efficacy of the Eustachian Tube Dysfunction Questionnaire (ETDQ-7) for patulous Eustachian tube (PET) patients. A prospective survey of medical records identified 36 patients and 47 ears with PET, and 15 patients and 15 ears as control. The ETDQ-7, patulous Eustachian tube handicap inventory-10 (PHI-10) and Likert scale were evaluated. PET patients were divided into two groups based on severity of symptoms using the PHI score. The Cronbach α value of the PET group was 0.765. The average total score of the ETDQ-7 in the control group was 7.6 ± 1.1 and 22.5 ± 10.0 in the PET group (p < .01). No correlation was found between ETDQ-7 and Likert scale (r = 0.248, p = .09). The average total score of the ETDQ-7 in the mild or moderate PET group was 19.9 ± 9.0 and 25.3 ± 11.1 in the severe PET group and this was not statistically different (p = .08). The highest ETDQ-7 score was also observed in PET patients and in ET dysfunction patients. These findings necessitate careful discrimination between ET dysfunction and PET in balloon dilation Eustachian tuboplasty (BET) based on ETDQ-7.
Wang, Chongqing; Wang, Hui; Fu, Jiangang; Zhang, Lingling; Luo, Chengcheng; Liu, Younian
2015-11-01
Surface modification with potassium permanganate (KMnO4) solution was developed for separation of polyvinyl chloride (PVC) and polyethylene terephthalate (PET) waste plastics. The floatability of PVC decreases with increasing of KMnO4 concentration, treatment time, temperature and stirring rate, while that of PET is unaffected. Fourier transform infrared (FT-IR) analysis confirms that mechanism of surface modification may be due to oxidization reactions occurred on PVC surface. The optimum conditions are KMnO4 concentration 1.25 mM/L, treatment time 50 min, temperature 60°C, stirring rate 300 r/min, frother concentration 17.5 g/L and flotation time 1 min. PVC and PET with different particle sizes were separated efficiently through two-stage flotation. Additionally, after ultrasonic assisted surface modification, separation of PVC and PET with different mass ratios was obtained efficiently through one-stage flotation. The purity and the recovery of the obtained products after flotation separation are up to 99.30% and 99.73%, respectively. A flotation process was designed for flotation separation of PVC and PET plastics combined with surface modification. This study provides technical insights into physical separation of plastic wastes for recycling industry. Copyright © 2015 Elsevier Ltd. All rights reserved.
Thai generic-brand dry canine foods: mutagenicity and the effects of feeding in vivo and in vitro.
Khuntamoon, Tanyalak; Thepouyporn, Apanchanid; Kaewprasert, Sarunya; Prangthip, Pattaneeya; Pooudoung, Somchai; Chaisri, Urai; Maneesai, Phudit; Kwanbunjan, Karunee
2016-01-20
The commercial pet-food industry and the market value of the pet industry have increased. Most owners are concerned about their pets' health, and prefer commercial pet foods as their regular diet. This study thus aimed to determine whether a selection of local generic-brand dry canine foods had any potential to promote chronic disease. Five local, generic-brand, dry canine foods were studied for potential mutagenicity; the effects of long-term consumption were also observed in rats. All canine foods were extracted with distilled water and absolute ethanol. The Ames test was used to detect short-term genetic damage, using Salmonella typhimurium tester strains TA98 and TA100. Simultaneously, the long-term effects were studied in an animal model by observing rats fed with these canine foods, compared with normal rat food, for a period of 15 weeks. Using the water extracts, all dry canine foods studied showed considerable mutagenic effects on the tester strains. One brand affected both tester strains, whereas 3 showed positive to TA98, and one to TA100. With the absolute ethanol extract, three of the five brands had a considerable mutagenic effect on TA98, and another affected TA100. In the long-term test, all rats remained alive until the end of the experiment, exhibited no apparent signs of toxicity or serious illness, and maintained normal bodyweight and weight gain. Serum blood biochemistry and hematological parameters in canine food-fed rats showed some negative effects. Correspondingly, histopathological investigation of their liver and kidneys showed deterioration. Mutagenic potential and the negative potential health impacts were observed in all local-brand dry canine foods tested.
NASA Astrophysics Data System (ADS)
Kamińska, D.; Gajos, A.; Czerwiński, E.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Dulski, K.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedźwiecka, M.; Raczyński, L.; Rudy, Z.; Silarski, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
2016-08-01
We present a study of the application of the Jagiellonian positron emission tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the { o-Ps }→ 3γ decays with angular and energy resolution equal to σ (θ ) ≈ {0.4°} and σ (E) ≈ 4.1 {keV}, respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pile-ups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.
Livieratos, L; Stegger, L; Bloomfield, P M; Schafers, K; Bailey, D L; Camici, P G
2005-07-21
High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.
Electron-stimulated reactions in nanoscale water films adsorbed on α-Al 2O 3 (0001)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrik, Nikolay G.; Kimmel, Gregory A.
The radiation-induced decomposition and desorption of nanoscale amorphous solid water (D2O) films adsorbed on -Al2O3(0001) surface was studied at low temperature in ultrahigh vacuum using temperature programmed desorption (TPD) and electron stimulated desorption (ESD) with a mono-energetic, low energy electron source. ESD yields of molecular products ( D2, O2 and D¬2O) and the total sputtering yield increased with increasing D2O coverage up to ~15 water monolayers (i.e. ~15 1015 cm-2) to a coverage-independent level for thicker water films. Experiments with isotopically-layered water films (D2O and H2O) demonstrated that the highest water decomposition yields occurred at the interfaces of the nanoscalemore » water films with the alumina substrate and vacuum. However, the increased reactivity of the water/alumina interface is relatively small compared to the enhancements in the non-thermal reactions previously observed at the water/Pt(111) and water/TiO2(110) interfaces. We propose that the relatively low activity of Al2O3(0001) for the radiation-induced production of molecular hydrogen is associated with lower reactivity of this surface with hydrogen atoms, which are likely precursors for the molecular hydrogen.100 eV electrons are stopped in the H 2O portion of the isotopically-layered nanoscale film on α-Al 2O 3(0001) but D 2is produced at the D 2O/alumina interface by mobile electronic excitations and/or hydronium ions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weiss, Charles J.; Egbert, Jonathan D.; Chen, Shentan
2014-04-28
Treatment of trans-[W(N2)2(dppe)(PEtNMePEt)] (dppe = Ph2PCH2CH2PPh2; PEtNMePEt = Et2PCH2N(Me)CH2PEt2) with three equivalents of tetrafluoroboric acid (HBF4∙Et2O) at -78 °C generated the seven-coordinate tungsten hydride trans-[W(N2)2(H)(dppe)(PEtNMePEt)][BF4]. Depending on the temperature of the reaction, protonation of a pendant amine is also observed, affording trans-[W(N2)2(H)(dppe)(PEtNMe(H)PEt)][BF4]2, with formation of the hydrazido complex, [W(NNH2)(dppe)(PEtNMe(H)PEt)][BF4]2, as a minor product. Similar product mixtures were obtained using triflic acid (HOTf). Upon acid addition to the carbonyl analogue, cis-[W(CO)2(dppe)(PEtNMePEt)], the seven-coordinate carbonyl-hydride complex, trans-[W(CO)2(H)(dppe)(PEtN(H)MePEt)][OTf]2 was generated. The mixed diphosphine complex without the pendant amine in the ligand backbone, trans-[W(N2)2(dppe)(depp)] (depp = Et2P(CH2)3PEt2), was synthesized and treated with HBF4∙Et2O, selectivelymore » generating a hydrazido complex, [W(NNH2)(F)(dppe)(depp)][BF4]. Computational analysis was used to probe proton affinity of three sites of protonation, the metal, pendant amine, and N2 ligand in these complexes. Room temperature reactions with 100 equivalents of HOTf produced NH4+ from reduction of the N2 ligand (electrons come from W). The addition of 100 equivalents HOTf to trans-[W(N2)2(dppe)(PEtNMePEt)] afforded 0.88 ± 0.02 equivalents NH4+, while 0.36 ± 0.02 equivalents of NH4+was formed upon treatment of trans-[W(N2)2(dppe)(depp)], the complex without the pendant amine. This work was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy Office of Science, Office of Basic Energy Sciences. Computational resources were provided by the National Energy Research Scientific Computing Center (NERSC) at Lawrence Berkeley National Laboratory. Pacific Northwest National Laboratory is operated by Battelle for DOE.« less
Modelling PET radionuclide production in tissue and external targets using Geant4
NASA Astrophysics Data System (ADS)
Amin, T.; Infantino, A.; Lindsay, C.; Barlow, R.; Hoehr, C.
2017-07-01
The Proton Therapy Facility in TRIUMF provides 74 MeV protons extracted from a 500 MeV H- cyclotron for ocular melanoma treatments. During treatment, positron emitting radionuclides such as 1C, 15O and 13N are produced in patient tissue. Using PET scanners, the isotopic activity distribution can be measured for in-vivo range verification. A second cyclotron, the TR13, provides 13 MeV protons onto liquid targets for the production of PET radionuclides such as 18F, 13N or 68Ga, for medical applications. The aim of this work was to validate Geant4 against FLUKA and experimental measurements for production of the above-mentioned isotopes using the two cyclotrons. The results show variable degrees of agreement. For proton therapy, the proton-range agreement was within 2 mm for 11C activity, whereas 13N disagreed. For liquid targets at the TR13 the average absolute deviation ratio between FLUKA and experiment was 1.9±2.7, whereas the average absolute deviation ratio between Geant4 and experiment was 0. 6±0.4. This is due to the uncertainties present in experimentally determined reaction cross sections.
NASA Astrophysics Data System (ADS)
Kamardin, Ili Liyana Khairunnisa; Ainuddin, Ainun Rahmahwati
2017-04-01
Transparent Conducting Oxide (TCO) Film has been chosen as flexible substrate recently in the application of a device. One of the TCO mostly used is ITO/PET substrates. Through this communication, the effect of time exposure of ZnO thin film by modified sol-gel deposited on flexible substrates was investigated. 0.75 M of NaOH and C6H8O7 were dropped directly into precursor solution right before aging process in order to modified precursor solution environment condition. x-ray diffraction pattern recorded plane (100) and (101) as preferential growth orientation. The (101) plane was selected to calculate the average crystallite. The atomic force microscopy indicated RMS value for NaOH samples increased with time exposure. Meanwhile, for C6H8O7 samples decreased with hot water treatment time exposure.
Yang, Jaewon; Jian, Yiqiang; Jenkins, Nathaniel; Behr, Spencer C; Hope, Thomas A; Larson, Peder E Z; Vigneron, Daniel; Seo, Youngho
2017-07-01
Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional review board-approved study. All patients underwent whole-body fluorodeoxyglucose PET/computed tomography (CT) followed by TOF PET/MR imaging. With use of TOF PET data, PET images were reconstructed with four different attenuation correction (AC) methods: PET with patient CT-based AC (CTAC), PET with ATAC (air and bone from an atlas), PET with ATAC patientBone (air and tissue from the atlas with patient bone), and PET with ATAC boneless (air and tissue from the atlas without bone). For quantitative evaluation, PET mean activity concentration values were measured in 14 1-mL volumes of interest (VOIs) distributed throughout the brain and statistical significance was tested with a paired t test. Results The mean overall difference (±standard deviation) of PET with ATAC compared with PET with CTAC was -0.69 kBq/mL ± 0.60 (-4.0% ± 3.2) (P < .001). The results were patient dependent (range, -9.3% to 0.57%) and VOI dependent (range, -5.9 to -2.2). In addition, when bone was not included for AC, the overall difference of PET with ATAC boneless (-9.4% ± 3.7) was significantly worse than that of PET with ATAC (-4.0% ± 3.2) (P < .001). Finally, when patient bone was used for AC instead of atlas bone, the overall difference of PET with ATAC patientBone (-1.5% ± 1.5) improved over that of PET with ATAC (-4.0% ± 3.2) (P < .001). Conclusion ATAC in PET/MR imaging achieves similar quantification accuracy to that from CTAC by means of atlas-based bone compensation. However, patient-specific anatomic differences from the atlas causes bone attenuation differences and misclassified sinuses, which result in patient-dependent performance variation of ATAC. © RSNA, 2017 Online supplemental material is available for this article.
Jiang, Jing; Liu, Gang; Shi, Suhua; Li, Zhigang
2016-01-01
Objectives . To compare musical electroacupuncture and electroacupuncture in a mouse model of Alzheimer's disease. Methods . In this study, 7.5-month-old male senescence-accelerated mouse prone 8 (SAMP8) mice were used as an Alzheimer's disease animal model. In the normal control paradigm, 7.5-month-old male SAMR1 mice were used as the blank control group (N group). After 15 days of treatment, using Morris water maze test, micro-PET, and immunohistochemistry, the differences among the musical electroacupuncture (MEA), electroacupuncture (EA), Alzheimer's disease (AD), and normal (N) groups were assessed. Results . The Morris water maze test, micro-PET, and immunohistochemistry revealed that MEA and EA therapies could improve spatial learning and memory ability, glucose metabolism level in the brain, and A β amyloid content in the frontal lobe, compared with the AD group ( P < 0.05). Moreover, MEA therapy performed better than EA treatment in decreasing amyloid-beta levels in the frontal lobe of mice with AD. Conclusion . MEA therapy may be superior to EA in treating Alzheimer's disease as demonstrated in SAMP8 mice.
Jiang, Jing; Liu, Gang
2016-01-01
Objectives. To compare musical electroacupuncture and electroacupuncture in a mouse model of Alzheimer's disease. Methods. In this study, 7.5-month-old male senescence-accelerated mouse prone 8 (SAMP8) mice were used as an Alzheimer's disease animal model. In the normal control paradigm, 7.5-month-old male SAMR1 mice were used as the blank control group (N group). After 15 days of treatment, using Morris water maze test, micro-PET, and immunohistochemistry, the differences among the musical electroacupuncture (MEA), electroacupuncture (EA), Alzheimer's disease (AD), and normal (N) groups were assessed. Results. The Morris water maze test, micro-PET, and immunohistochemistry revealed that MEA and EA therapies could improve spatial learning and memory ability, glucose metabolism level in the brain, and Aβ amyloid content in the frontal lobe, compared with the AD group (P < 0.05). Moreover, MEA therapy performed better than EA treatment in decreasing amyloid-beta levels in the frontal lobe of mice with AD. Conclusion. MEA therapy may be superior to EA in treating Alzheimer's disease as demonstrated in SAMP8 mice. PMID:27974974
Proposed system design for a 20 kW pulsed electrothermal thruster
NASA Technical Reports Server (NTRS)
Burton, R. L.; Goldstein, S. A.; Hilko, B. K.; Tidman, D. A.; Winsor, N. K.
1984-01-01
A conceptual design is presented for a Pulsed Electrothermal (PET) propulsion system for the Air Force Space Based Radar satellite, which has a mass of 7000 kg. The proposed system boosts the SBR satellite from 150 n.m. to 600 n.m. with a 4 deg plane change, for a total mission Delta v of 1 km/sec. Satellite power available is 50 kW, and 45 kW are used to drive two water-injected 20 kW PET thrusters, delivering 5.6 N thrust to the SBR at 1000 seconds specific impulse. The predicted mission trip time is 15 days. The proposed system consumes 850 kg of water propellant, stored in a central tank and injected with pressurized helium. Component mass estimates based on space-qualified hardware are presented for the propellant handling, power conditioning and thruster subsystems. The estimated total mass is 400 kg and the propulsion system specific mass is alpha = 10 kg/kW. The proposed system efficiency of 0.62 at 1000 seconds specific impulse is supported by experimental performance measurements.
32nd International Austrian Winter Symposium : Zell am See, the Netherlands. 20-23 January 2016.
Langsteger, W; Rezaee, A; Loidl, W; Geinitz, H S; Fitz, F; Steinmair, M; Broinger, G; Pallwien-Prettner, L; Beheshti, M; Imamovic, L; Beheshti, M; Rendl, G; Hackl, D; Tsybrovsky, O; Steinmair, M; Emmanuel, K; Moinfar, F; Pirich, C; Langsteger, W; Bytyqi, A; Karanikas, G; Mayerhöfer, M; Koperek, O; Niederle, B; Hartenbach, M; Beyer, T; Herrmann, K; Czernin, J; Rausch, I; Rust, P; DiFranco, M D; Lassen, M; Stadlbauer, A; Mayerhöfer, M E; Hartenbach, M; Hacker, M; Beyer, T; Binzel, K; Magnussen, R; Wei, W; Knopp, M U; Flanigan, D C; Kaeding, C; Knopp, M V; Leisser, A; Nejabat, M; Hartenbach, M; Kramer, G; Krainer, M; Hacker, M; Haug, A; Lehnert, Wencke; Schmidt, Karl; Kimiaei, Sharok; Bronzel, Marcus; Kluge, Andreas; Wright, C L; Binzel, K; Zhang, J; Wuthrick, Evan; Maniawski, Piotr; Knopp, M V; Blaickner, M; Rados, E; Huber, A; Dulovits, M; Kulkarni, H; Wiessalla, S; Schuchardt, C; Baum, R P; Knäusl, B; Georg, D; Bauer, M; Wulkersdorfer, B; Wadsak, W; Philippe, C; Haslacher, H; Zeitlinger, M; Langer, O; Bauer, M; Feldmann, M; Karch, R; Wadsak, W; Zeitlinger, M; Koepp, M J; Asselin, M-C; Pataraia, E; Langer, O; Zeilinger, M; Philippe, C; Dumanic, M; Pichler, F; Pilz, J; Hacker, M; Wadsak, W; Mitterhauser, M; Nics, L; Steiner, B; Hacker, M; Mitterhauser, M; Wadsak, W; Traxl, A; Wanek, Thomas; Kryeziu, Kushtrim; Mairinger, Severin; Stanek, Johann; Berger, Walter; Kuntner, Claudia; Langer, Oliver; Mairinger, S; Wanek, T; Traxl, A; Krohn, M; Stanek, J; Filip, T; Sauberer, M; Kuntner, C; Pahnke, J; Langer, O; Svatunek, D; Denk, C; Wilkovitsch, M; Wanek, T; Filip, T; Kuntner-Hannes, C; Fröhlich, J; Mikula, H; Denk, C; Svatunek, D; Wanek, T; Mairinger, S; Stanek, J; Filip, T; Fröhlich, J; Mikula, H; Kuntner-Hannes, C; Balber, T; Singer, J; Fazekas, J; Rami-Mark, C; Berroterán-Infante, N; Jensen-Jarolim, E; Wadsak, W; Hacker, M; Viernstein, H; Mitterhauser, M; Denk, C; Svatunek, D; Sohr, B; Mikula, H; Fröhlich, J; Wanek, T; Kuntner-Hannes, C; Filip, T; Pfaff, S; Philippe, C; Mitterhauser, M; Hartenbach, M; Hacker, M; Wadsak, W; Wanek, T; Halilbasic, E; Visentin, M; Mairinger, S; Stieger, B; Kuntner, C; Trauner, M; Langer, O; Lam, P; Aistleitner, M; Eichinger, R; Artner, C; Eidherr, H; Vraka, C; Haug, A; Mitterhauser, M; Nics, L; Hartenbach, M; Hacker, M; Wadsak, W; Kvaternik, H; Müller, R; Hausberger, D; Zink, C; Aigner, R M; Cossío, U; Asensio, M; Montes, A; Akhtar, S; Te Welscher, Y; van Nostrum, R; Gómez-Vallejo, V; Llop, J; VandeVyver, F; Barclay, T; Lippens, N; Troch, M; Hehenwarter, L; Egger, B; Holzmannhofer, J; Rodrigues-Radischat, M; Pirich, C; Pötsch, N; Rausch, I; Wilhelm, D; Weber, M; Furtner, J; Karanikas, G; Wöhrer, A; Mitterhauser, M; Hacker, M; Traub-Weidinger, T; Cassou-Mounat, T; Balogova, S; Nataf, V; Calzada, M; Huchet, V; Kerrou, K; Devaux, J-Y; Mohty, M; Garderet, L; Talbot, J-N; Stanzel, S; Pregartner, G; Schwarz, T; Bjelic-Radisic, V; Liegl-Atzwanger, B; Aigner, R; Stanzel, S; Quehenberger, F; Aigner, R M; Marković, A Koljević; Janković, Milica; Jerković, V Miler; Paskaš, M; Pupić, G; Džodić, R; Popović, D; Fornito, M C; Familiari, D; Koranda, P; Polzerová, H; Metelková, I; Henzlová, L; Formánek, R; Buriánková, E; Kamínek, M; Thomson, W H; Lewis, C; Thomson, W H; O'Brien, J; James, G; Notghi, A; Huber, H; Stelzmüller, I; Wunn, R; Mandl, M; Fellner, F; Lamprecht, B; Gabriel, M; Fornito, M C; Leonardi, G; Thomson, W H; O'Brien, J; James, G; Hudzietzová, J; Sabol, J; Fülöp, M
2016-04-01
A1 68Ga-PSMA PET/CT in staging and restaging of Prostate Cancer Patients: comparative study with 18F-Choline PET/CTW Langsteger, A Rezaee, W Loidl, HS Geinitz, F Fitz, M Steinmair, G Broinger, L Pallwien-Prettner, M BeheshtiA2 F18 Choline PET - CT: an accurate diagnostic tool for the detection of parathyroid adenoma?L Imamovic, M Beheshti, G Rendl, D Hackl, O Tsybrovsky, M Steinmair, K Emmanuel, F Moinfar, C Pirich, W LangstegerA3 [18F]Fluoro-DOPA-PET/CT in the primary diagnosis of medullary thyroid carcinomaA Bytyqi, G Karanikas, M Mayerhöfer, O Koperek, B Niederle, M HartenbachA4 Variations of clinical PET/MR operations: An international survey on the clinical utilization of PET/MRIT Beyer, K Herrmann, J CzerninA5 Standard Dixon-based attenuation correction in combined PET/MRI: Reproducibility and the possibility of Lean body mass estimationI Rausch, P Rust, MD DiFranco, M Lassen, A Stadlbauer, ME Mayerhöfer, M Hartenbach, M Hacker, T BeyerA6 High resolution digital FDG PET/MRI imaging for assessment of ACL graft viabilityK Binzel, R Magnussen, W Wei, MU Knopp, DC Flanigan, C Kaeding, MV KnoppA7 Using pre-existing hematotoxicity as predictor for severe side effects and number of treatment cycles of Xofigo therapyA Leisser, M Nejabat, M Hartenbach, G Kramer, M Krainer, M Hacker, A HaugA8 QDOSE - comprehensive software solution for internal dose assessmentWencke Lehnert, Karl Schmidt, Sharok Kimiaei, Marcus Bronzel, Andreas KlugeA9 Clinical impact of Time-of-Flight on next-generation digital PET imaging of Yttrium-90 radioactivity following liver radioembolizationCL Wright, K Binzel, J Zhang, Evan Wuthrick, Piotr Maniawski, MV KnoppA10 Snakes in patients! Lessons learned from programming active contours for automated organ segmentationM Blaickner, E Rados, A Huber, M Dulovits, H Kulkarni, S Wiessalla, C Schuchardt, RP Baum, B Knäusl, D GeorgA11 Influence of a genetic polymorphism on brain uptake of the dual ABCB1/ABCG2 substrate [11C]tariquidarM Bauer, B Wulkersdorfer, W Wadsak, C Philippe, H Haslacher, M Zeitlinger, O LangerA12 Outcome prediction of temporal lobe epilepsy surgery from P-glycoprotein activity. Pooled analysis of (R)-[11C]-verapamil PET data from two European centresM Bauer, M Feldmann, R Karch, W Wadsak, M Zeitlinger, MJ Koepp, M-C Asselin, E Pataraia, O LangerA13 In-vitro and in-vivo characterization of [18F]FE@SNAP and derivatives for the visualization of the melanin concentrating hormone receptor 1M Zeilinger, C Philippe, M Dumanic, F Pichler, J Pilz, M Hacker, W Wadsak, M MitterhauserA14 Reducing time in quality control leads to higher specific radioactivity of short-lived radiotracersL Nics, B Steiner, M Hacker, M Mitterhauser, W WadsakA15 In vitro 11C-erlotinib binding experiments in cancer cell lines with epidermal growth factor receptor mutationsA Traxl, Thomas Wanek, Kushtrim Kryeziu, Severin Mairinger, Johann Stanek, Walter Berger, Claudia Kuntner, Oliver LangerA16 7-[11C]methyl-6-bromopurine, a PET tracer to measure brain Mrp1 function: radiosynthesis and first PET evaluation in miceS Mairinger, T Wanek, A Traxl, M Krohn, J Stanek, T Filip, M Sauberer, C Kuntner, J Pahnke, O LangerA17 18F labeled azidoglucose derivatives as "click" agents for pretargeted PET imagingD Svatunek, C Denk, M Wilkovitsch, T Wanek, T Filip, C Kuntner-Hannes, J Fröhlich, H MikulaA18 Bioorthogonal tools for PET imaging: development of radiolabeled 1,2,4,5-TetrazinesC Denk, D Svatunek, T Wanek, S Mairinger, J Stanek, T Filip, J Fröhlich, H Mikula, C Kuntner-HannesA19 Preclinical evaluation of [18F]FE@SUPPY- a new PET-tracer for oncologyT Balber, J Singer, J Fazekas, C Rami-Mark, N Berroterán-Infante, E Jensen-Jarolim, W Wadsak, M Hacker, H Viernstein, M MitterhauserA20 Investigation of Small [18F]-Fluoroalkylazides for Rapid Radiolabeling and In Vivo Click ChemistryC Denk, D Svatunek, B Sohr, H Mikula, J Fröhlich, T Wanek, C Kuntner-Hannes, T FilipA21 Microfluidic 68Ga-radiolabeling of PSMA-HBED-CC using a flow-through reactorS Pfaff, C Philippe, M Mitterhauser, M Hartenbach, M Hacker, W WadsakA22 Influence of 24-nor-ursodeoxycholic acid on hepatic disposition of [18F]ciprofloxacin measured with positron emission tomographyT Wanek, E Halilbasic, M Visentin, S Mairinger, B Stieger, C Kuntner, M Trauner, O LangerA23 Automated 18F-flumazenil production using chemically resistant disposable cassettesP Lam, M Aistleitner, R Eichinger, C ArtnerA24 Similarities and differences in the synthesis and quality control of 177Lu-DOTA-TATE, 177Lu -HA-DOTA-TATE and 177Lu-DOTA-PSMA (PSMA-617)H Eidherr, C Vraka, A Haug, M Mitterhauser, L Nics, M Hartenbach, M Hacker, W WadsakA25 68Ga- and 177Lu-labelling of PSMA-617H Kvaternik, R Müller, D Hausberger, C Zink, RM AignerA26 Radiolabelling of liposomes with 67Ga and biodistribution studies after administration by an aerosol inhalation systemU Cossío, M Asensio, A Montes, S Akhtar, Y te Welscher, R van Nostrum, V Gómez-Vallejo, J LlopA27 Fully automated quantification of DaTscan SPECT: Integration of age and gender differencesF VandeVyver, T Barclay, N Lippens, M TrochA28 Lesion-to-background ratio in co-registered 18F-FET PET/MR imaging - is it a valuable tool to differentiate between low grade and high grade brain tumor?L Hehenwarter, B Egger, J Holzmannhofer, M Rodrigues-Radischat, C PirichA29 [11C]-methionine PET in gliomas - a retrospective data analysis of 166 patientsN Pötsch, I Rausch, D Wilhelm, M Weber, J Furtner, G Karanikas, A Wöhrer, M Mitterhauser, M Hacker, T Traub-WeidingerA30 18F-Fluorocholine versus 18F-Fluorodeoxyglucose for PET/CT imaging in patients with relapsed or progressive multiple myeloma: a pilot studyT Cassou-Mounat, S Balogova, V Nataf, M Calzada, V Huchet, K Kerrou, J-Y Devaux, M Mohty, L Garderet, J-N TalbotA31 Prognostic benefit of additional SPECT/CT in sentinel lymph node mapping of breast cancer patientsS Stanzel, G Pregartner, T Schwarz, V Bjelic-Radisic, B Liegl-Atzwanger, R AignerA32 Evaluation of diagnostic value of TOF-18F-FDG PET/CT in patients with suspected pancreatic cancerS Stanzel, F Quehenberger, RM AignerA33 New quantification method for diagnosis of primary hyperpatahyroidism lesions and differential diagnosis vs thyropid nodular disease in dynamic scintigraphyA Koljević Marković, Milica Janković, V Miler Jerković, M Paskaš, G Pupić, R Džodić, D PopovićA34 A rare case of diffuse pancreatic involvement in patient with merkel cell carcinoma detected by 18F-FDGMC Fornito, D FamiliariA35 TSH-stimulated 18F-FDG PET/CT in the diagnosis of recurrent/metastatic radioiodine-negative differentiated thyroid carcinomas in patients with various thyroglobuline levelsP Koranda, H Polzerová, I Metelková, L Henzlová, R Formánek, E Buriánková, M KamínekA36 Breast Dose from lactation following I131 treatmentWH Thomson, C LewisA37 A new concept for performing SeHCAT studies with the gamma cameraWH Thomson, J O'Brien, G James, A NotghiA38 Whole body F-18-FDG-PET and tuberculosis: sensitivity compared to x-ray-CTH Huber, I Stelzmüller, R Wunn, M Mandl, F Fellner, B Lamprecht, M GabrielA39 Emerging role 18F-FDG PET-CT in the diagnosis and follow-up of the infection in heartware ventricular assist system (HVAD)MC Fornito, G LeonardiA40 Validation of Poisson resampling softwareWH Thomson, J O'Brien, G JamesA41 Protection of PET nuclear medicine personnel: problems in satisfying dose limit requirementsJ Hudzietzová, J Sabol, M Fülöp.
Applying Energy Conservation Retrofits to Standard Army Buildings: Data Analysis and Recommendations
1990-09-01
than mechanical. The line titled "Mechanical" includes all line items related to electrical work, HVAC work, and controls. A 25 pet..ctit mark-up is...criteria specify a life of 15 years for HVAC retrofits and a 25-year life for weatherization, calculations were performed for both lifetimes for...circulation pump was serviced. "• Smaller sized steam valves and actuators were installed in the hot water converters. "* New pneumatic heating reset
Observation of practices at petting zoos and the potential impact on zoonotic disease transmission.
Weese, J Scott; McCarthy, Lisa; Mossop, Michael; Martin, Hayley; Lefebvre, Sandi
2007-07-01
Although petting zoos are common at public events and allow the public to interact with animals, there has been minimal evaluation of practices at petting zoos. Unannounced observation was performed at 36 petting zoos in Ontario, Canada. Observers recorded information, including physical layout, animal species, animal health, types of animal contact permitted, animal sources, hand hygiene facilities, signage, sale of food for human consumption, and hand hygiene compliance. The majority of petting zoos (24 [67%] of 36 petting zoos) were part of temporary events, particularly agricultural fairs (21 [58%] of 36 petting zoos). A variety of animal species were present, including some animals that are considered to be at particularly high risk for disease transmission (neonatal calves and baby chicks). The following items that would come into contact with the mouths of infants and children were carried into the petting zoos: baby bottles (at 17 petting zoos; 50%), pacifiers (at 24 petting zoos; 71%), spill-proofs cups (at 19 petting zoos; 56%), and infant toys (at 22 petting zoos; 65%). Hand hygiene facilities were provided at 34 (94%) of 36 events, and hand hygiene compliance ranged from 0% through 77% (mean compliance [+/-SD], 30.9%+/-22.1%; median compliance, 26.5%). Predictors for increased hand hygiene compliance included the location of a hand hygiene station on an exit route, the presence of hand hygiene reminder signs, and the availability of running water. Numerous deficiencies were encountered. Better education of petting zoo operators and the general public is needed. Provision of hand hygiene stations with running water that are placed near exits is one effective way to encourage compliance.
Assessment of Oxidative Metabolism in Brown Fat Using PET Imaging
Muzik, Otto; Mangner, Thomas J.; Granneman, James G.
2011-01-01
Objective: Although it has been believed that brown adipose tissue (BAT) depots disappear shortly after the perinatal period in humans, positron emission tomography (PET) imaging using the glucose analog 18F-deoxy-d-glucose (FDG) has shown unequivocally the existence of functional BAT in humans, suggesting that most humans have some functional BAT. The objective of this study was to determine, using dynamic oxygen-15 (15O) PET imaging, to what extent BAT thermogenesis is activated in adults during cold stress and to establish the relationship between BAT oxidative metabolism and FDG tracer uptake. Methods: Fourteen adult normal subjects (9F/5M, 30 ± 7 years) underwent triple oxygen scans (H215O, C15O, 15O2) as well as indirect calorimetric measurements at both rest and following exposure to mild cold (16°C). Subjects were divided into two groups (BAT+ and BAT−) based on the presence or absence of FDG tracer uptake (SUV > 2) in cervical–supraclavicular BAT. Blood flow and oxygen extraction fraction (OEF) was calculated from dynamic PET scans at the location of BAT, muscle, and white adipose tissue (WAT). The metabolic rate of oxygen (MRO2) in BAT was determined and used to calculate the contribution of activated BAT to daily energy expenditure (DEE). Results: The median mass of activated BAT in the BAT+ group (5F, age 31 ± 8) was 52.4 g (range 14–68 g) and was 1.7 g (range 0–6.3 g) in the BAT − group (5M/4F, age 29 ± 6). Corresponding SUV values were significantly higher in the BAT+ as compared to the BAT− group (7.4 ± 3.7 vs. 1.9 ± 0.9; p = 0.03). Blood flow values in BAT were significantly higher in the BAT+ group as compared to the BAT− group (13.1 ± 4.4 vs. 5.7 ± 1.1 ml/100 g/min, p = 0.03), but were similar in WAT (4.1 ± 1.6 vs. 4.2 ± 1.8 ml/100 g/min) and muscle (3.7 ± 0.8 vs. 3.3 ± 1.2 ml/100 g/min). Moreover, OEF in BAT was similar in the two groups (0.56 ± 0.18 in BAT+ vs. 0.46 ± 0.19 in BAT−, p = 0.39). Calculated MRO2 values in BAT increased from 0.95 ± 0.74 to 1.62 ± 0.82 ml/100 g/min in the BAT+ group and were significantly higher than those determined in the BAT− group (0.43 ± 0.27 vs. 0.56 ± 0.24, p = 0.67). The DEE associated with BAT oxidative metabolism was highly variable in the BAT+ group, with an average of 5.5 ± 6.4 kcal/day (range 0.57–15.3 kcal/day). Conclusion: BAT thermogenesis in humans accounts for less than 20 kcal/day during moderate cold stress, even in subjects with relatively large BAT depots. Furthermore, due to the large differences in blood flow and glucose metabolic rates in BAT between humans and rodents, the application of rodent data to humans is problematic and needs careful evaluation. PMID:22649408
NASA Astrophysics Data System (ADS)
Hariyanto, Sucipto; Usman, Mohammad Nurdianfajar; Citrasari, Nita
2017-06-01
This research aim is to determine the best briquettes as implementation of wastes recycle based on scoring method, main component composition, compressive strength, caloric value, water content, vollatile content, and ash content, also the suitability with SNI 01-6235-2000. Main component that used are rice husk, 2mm and 6 mm PET, and dried leaves. Composition variation in this research are marked as K1, K2, K3, K4, and K5 with 2 mm PET plastic and K1, K2, K3, K4, and K5 with 6 mm PET plastic. The total weight of the briquettes is 100 g and divided into 90% main components and 10% tapioca as binder. The compressive strength, caloric value, water content, vollatile content, and ash content were tested according to ASTM D 5865-04, ASTM D 3173-03, ASTM D 3175-02, ASTM D 3174-02. The tested results were used to determine the best briquette by scoring method, and the chosen briquettes is K2 with 6 mm PET plastic. The composition is 70% rice husk, 20% 6 mm PET plastic, and 10% dried leaves with the compressive strength, caloric value, water content, vollatile content, and ash content value is 51,55 kg/cm2; 5123 kal/g; 3,049%; 31,823%, dan 12,869%. The suitable value that meet the criteria according to SNI 01-6235-2000 is compressive strength, caloric value, water content, and ash content.
Validation of a 4D-PET Maximum Intensity Projection for Delineation of an Internal Target Volume
DOE Office of Scientific and Technical Information (OSTI.GOV)
Callahan, Jason, E-mail: jason.callahan@petermac.org; Kron, Tomas; Peter MacCallum Department of Oncology, The University of Melbourne, Melbourne
2013-07-15
Purpose: The delineation of internal target volumes (ITVs) in radiation therapy of lung tumors is currently performed by use of either free-breathing (FB) {sup 18}F-fluorodeoxyglucose-positron emission tomography-computed tomography (FDG-PET/CT) or 4-dimensional (4D)-CT maximum intensity projection (MIP). In this report we validate the use of 4D-PET-MIP for the delineation of target volumes in both a phantom and in patients. Methods and Materials: A phantom with 3 hollow spheres was prepared surrounded by air then water. The spheres and water background were filled with a mixture of {sup 18}F and radiographic contrast medium. A 4D-PET/CT scan was performed of the phantom whilemore » moving in 4 different breathing patterns using a programmable motion device. Nine patients with an FDG-avid lung tumor who underwent FB and 4D-PET/CT and >5 mm of tumor motion were included for analysis. The 3 spheres and patient lesions were contoured by 2 contouring methods (40% of maximum and PET edge) on the FB-PET, FB-CT, 4D-PET, 4D-PET-MIP, and 4D-CT-MIP. The concordance between the different contoured volumes was calculated using a Dice coefficient (DC). The difference in lung tumor volumes between FB-PET and 4D-PET volumes was also measured. Results: The average DC in the phantom using 40% and PET edge, respectively, was lowest for FB-PET/CT (DCAir = 0.72/0.67, DCBackground 0.63/0.62) and highest for 4D-PET/CT-MIP (DCAir = 0.84/0.83, DCBackground = 0.78/0.73). The average DC in the 9 patients using 40% and PET edge, respectively, was also lowest for FB-PET/CT (DC = 0.45/0.44) and highest for 4D-PET/CT-MIP (DC = 0.72/0.73). In the 9 lesions, the target volumes of the FB-PET using 40% and PET edge, respectively, were on average 40% and 45% smaller than the 4D-PET-MIP. Conclusion: A 4D-PET-MIP produces volumes with the highest concordance with 4D-CT-MIP across multiple breathing patterns and lesion sizes in both a phantom and among patients. Freebreathing PET/CT consistently underestimates ITV when compared with 4D PET/CT for a lesion affected by respiration.« less
Occurrence of Ornithonyssus sylviarum in pet birds from the district of Setúbal, Portugal.
Waap, Helga; Paulino, Diana; Cardoso, Rita
2017-07-01
Ornithonyssus sylviarum is a blood-feeding ectoparasite of birds and the most serious pest in poultry farms in North America. Although the mites are typically adapted to temperate climates, information on this mite in Europe is sparse, and Dermanyssus gallinae is considered to be the only mite impacting the poultry industry. The present study reports the occurrence of O. sylviarum in pet birds in Portugal. Mites were collected directly from birds and with traps placed in cages and nests at 20 different sampling places belonging to 6 municipalities in the district of Setúbal. In a total of 217 birds, O. sylviarum was identified in 47 out of 147 (32.0%) canaries (Serinus canaria), 14 out of 21 (14.3%) estrildid finches, 1 out of 24 (4.2%) budgerigars (Melopsittacus undulatus) and 1 out of 15 (6.7%) lovebirds (Agapornis spp.). Mites of the genus Dermanyssus were identified in 8 canaries (5.4%), 8 estrildid finches (38.1%) and 1 lovebird (6.7%). No mites were found in 6 cockatiels (Nymphicus hollandicus), 2 African grey parrots (Psittacus erithacus), 1 Bourke's parrot (Neophema bourkii) and 1 rose-ringed parakeet (Psittacula krameri). Considering the zoonotic potential and the risk of dissemination to poultry, the present findings underline the need for further monitoring of O. sylviarum in the wild and domestic avifauna in Portugal.
Elmi, Abdirashid A; Astatkie, Tess; Madramootoo, Chandra; Gordon, Robert; Burton, David
2005-01-01
The denitrification process and nitrous oxide (N2O) production in the soil profile are poorly documented because most research into denitrification has concentrated on the upper soil layer (0-0.15 m). This study, undertaken during the 1999 and 2000 growing seasons, was designed to examine the effects of water table management (WTM), nitrogen (N) application rate, and depth (0.15, 0.30, and 0.45 m) on soil denitrification end-products (N2O and N2) from a corn (Zea mays L.) field. Water table management treatments were free drainage (FD) with open drains and subirrigation (SI) with a target water table depth of 0.6 m. Fertility treatments (ammonium nitrate) were 120 kg N ha(-1) (N120) and 200 kg N ha(-1) (N200). During both growing seasons greater denitrification rates were measured in SI than in FD, particularly in the surface soil (0-0.15 m) and at the intermediate (0.15-0.30 m) soil depths under N200 treatment. Greater denitrification rates under the SI treatment, however, were not accompanied with greater N2O production. The decrease in N2O production under SI was probably caused by a more complete reduction of N2O to N2, which resulted in lower N2O to (N2O + N2) ratios. Denitrification rate, N2O production and N2O to (N2O + N2) ratios were only minimally affected by N treatments, irrespective of sampling date and soil depth. Overall, half of the denitrification occurred at the 0.15- to 0.30- and 0.30- to 0.45-m soil layers, and under SI, regardless of fertility treatment level. Consequently, sampling of the 0- to 0.15-m soil layer alone may not give an accurate estimation of denitrification losses under SI practice.
NASA Astrophysics Data System (ADS)
Schiepers, Christiaan; Hoh, Carl K.; Dahlbom, Magnus; Wu, Hsiao-Ming; Phelps, Michael E.
1999-05-01
PET imaging can quantify metabolic processes in-vivo; this requires the measurement of an input function which is invasive and labor intensive. A non-invasive, semi-automated, image based method of input function generation would be efficient, patient friendly, and allow quantitative PET to be applied routinely. A fully automated procedure would be ideal for studies across institutions. Factor analysis (FA) was applied as processing tool for definition of temporally changing structures in the field of view. FA has been proposed earlier, but the perceived mathematical difficulty has prevented widespread use. FA was utilized to delineate structures and extract blood and tissue time-activity-curves (TACs). These TACs were used as input and output functions for tracer kinetic modeling, the results of which were compared with those from an input function obtained with serial blood sampling. Dynamic image data of myocardial perfusion studies with N-13 ammonia, O-15 water, or Rb-82, cancer studies with F-18 FDG, and skeletal studies with F-18 fluoride were evaluated. Correlation coefficients of kinetic parameters obtained with factor and plasma input functions were high. Linear regression usually furnished a slope near unity. Processing time was 7 min/patient on an UltraSPARC. Conclusion: FA can non-invasively generate input functions from image data eliminating the need for blood sampling. Output (tissue) functions can be simultaneously generated. The method is simple, requires no sophisticated operator interaction and has little inter-operator variability. FA is well suited for studies across institutions and standardized evaluations.
SU-G-IeP4-07: Feasibility of Low Dose 18FDG PET in Pediatric Oncology Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Binzel, K; Hall, NC
Purpose: To evaluate and demonstrate the feasibility of low dose FDG PET in pediatric oncology patients using virtual dose reduction as well as true patients PET/CT scans. Methods: Wholebody 18F-FDG PET/CT of 39 clinical pediatric patients (0.16±0.06MBq/kg) were scanned on a Gemini TF 64 system at 75±5 min post FDG injection using 3min/bed. Based on the 180s/bed listmode PET data, subsets of total counts in 120s, 90s, 60s, 30s and 15s per bed position were extracted for PET reconstruction to simulate lower dose PET at 2/3th, 1/2th, 1/3th, 1/6th and 1/12th dose levels. PET/CT scans of Jaszczak PET phantom withmore » 6 hot hollow spheres varying with sizes and contrast ratios were performed (real PET versus simulated PET) to validate the methodology of virtual dose PET simulation. Region of interests (ROIs) were placed on lesions and normal anatomical tissues with quantitative and qualitative assessment performed. Significant lower FDG dose PET/CT of 5 research adolescents were scanned to validate the proposal and low dose PET feasibility. Results: Although all lesions are visible on the 1/12th dose PET, overall PET image quality appears to be influenced in a multi-factorial way. 30%–60% dose reduction from current standard of care FDG PET is recommended to maintain equivalent quality and PET quantification. An optimized BMI-based FDG administration is recommended (from 1.1±0.5 mCi for BMI < 18.5 to 4.8±1.5 mCi for BMI > 30). A linear lowest “Dose-BMI” relationship is given. SUVs from 1/12th to full dose PETs were identified as consistent (R2 = 1.08, 0.99, 1.01, 1.00 and 0.98). No significant variances of count density, SUV and SNR were found across certain dose ranges (p<0.01). Conclusion: Pediatric PET/CT can be performed using current time-of-flight systems at substantially lower PET doses (30–60%) than the standard of care PET/CT without compromising qualitative and quantitative image quality in clinical.« less
Naito, Y; Okazawa, H; Honjo, I; Hirano, S; Takahashi, H; Shiomi, Y; Hoji, W; Kawano, M; Ishizu, K; Yonekura, Y
1995-07-01
Six postlingually deaf patients using multi-channel cochlear implants were examined by positron emission tomography (PET) using 15O-labeled water. Changes in regional cerebral blood flow (rCBF) were measured during different sound stimuli. The stimulation paradigms employed consisted of two sets of three different conditions; (1) no sound stimulation with the speech processor of the cochlear implant system switched off, (2) hearing white noise and (3) hearing sequential Japanese sentences. In the primary auditory area, the mean rCBF increase during noise stimulation was significantly greater on the side contralateral to the implant than on the ipsilateral side. Speech stimulation caused significantly greater rCBF increase compared with noise stimulation in the left immediate auditory association area (P < 0.01), the bilateral auditory association areas (P < 0.01), the posterior part of the bilateral inferior frontal gyri; the Broca's area (P < 0.01) and its right hemisphere homologue (P < 0.05). Activation of cortices related to verbal and non-verbal sound recognition was clearly demonstrated in the current subjects probably because complete silence was attained in the control condition.
De Bruycker, Sven; Vangestel, Christel; Van den Wyngaert, Tim; Wyffels, Leonie; Wouters, An; Pauwels, Patrick; Staelens, Steven; Stroobants, Sigrid
2016-08-01
The purpose of this study was to characterize imaging biomarkers for the potential benefit of hypoxia-inducible factor-1 (HIF-1)α inhibition (by PX-12) during 5-fluorouracil (5-FU) chemotherapy in the treatment of colorectal cancer (CRC). Therapy response to 5-FU ± PX-12 was assessed with baseline [(18)F]fluoromisonidazole ([(18)F]FMISO) and longitudinal 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) positron emission computed tomography (μPET/CT) in CRC xenograft model (n = 36) during breathing of a hypoxic (10 % O2) or normoxic (21 % O2) atmosphere. Ex vivo, immunohistochemistry was performed. Baseline [(18)F]FMISO uptake and relative tumor volume (RTV) 2 days after 5-FU or 5-FU + PX-12 administration correlated significantly (p ≤ 0.01). Under hypoxic breathing conditions, [(18)F]FDG uptake (-53.1 ± 8.4 %) and Ki67 expression (-16 %) decreased and RTV stagnated in the 5-FU + PX-12 treatment group, but not in 5-FU alone-treated tumors. Under normoxic breathing, [(18)F]FDG uptake (-23.5 ± 15.2 % and -72.8 ± 7.1 %) and Ki67 expression (-5 % and -19 %) decreased and RTV stagnated in both the 5-FU and the combination treatment group, respectively. Baseline [(18)F]FMISO μPET may predict the beneficial effect of HIF-1α inhibition during 5-FU chemotherapy in CRC.
Richter, Doreen; Massmann, Gudrun; Dünnbier, Uwe
2008-03-01
Because of the nature of the water cycle in Berlin, a number of persistent wastewater residues are present in the surface water and may potentially reach the groundwater via bank filtration and artificial recharge. The occurrence and behaviour of the wastewater residues para-toluenesulphonamide (p-TSA), ortho-toluenesulphonamide (o-TSA) and benzenesulphonamide (BSA) through wastewater treatment, surface water, bank filtration and drinking water treatment was studied. In addition, groundwater below a former sewage farm was investigated. All three compounds are ubiquitous in the aquatic environment of Berlin. p-TSA concentrations are much higher than those of o-TSA and BSA. p-TSA was found in high concentrations in the wastewater influent (2 to 15microg/L), in the wastewater effluent (<0.15 to 2.34microg/L) and in sewage farm groundwater (<0.05 to 20microg/L) and in lower concentrations in the surface water (<0.05 to 1.15microg/L), bank filtrate (<0.05 to 0.30microg/L) and drinking water (<0.05 to 0.54microg/L). p-TSA is considerably depleted during waste- and drinking water treatment ( approximately 90% reduction each). The concentration ranges for o-TSA and BSA in wastewater influents were 0.11 to 8microg/L and <0.05 to 0.64microg/L, respectively, while the values for wastewater effluents were 0.14 to 4microg/L for o-TSA and 0.25 to 0.49microg/L for BSA. Wastewater treatment and drinking water treatment do not reduce the concentrations of o-TSA and BSA. The behaviour of o-TSA during wastewater treatment varies largely between different wastewater treatment plants where concentrations increase, remain constant or decrease. BSA forms during treatment. The concentrations measured in surface water, sewage farm groundwater, bank filtrate and drinking water were <0.05 to 1.74microg/L for o-TSA and <0.05 to 0.53microg/L for BSA.
Kebir, Sied; Khurshid, Zain; Gaertner, Florian C; Essler, Markus; Hattingen, Elke; Fimmers, Rolf; Scheffler, Björn; Herrlinger, Ulrich; Bundschuh, Ralph A; Glas, Martin
2017-01-31
Timely detection of pseudoprogression (PSP) is crucial for the management of patients with high-grade glioma (HGG) but remains difficult. Textural features of O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography (FET-PET) mirror tumor uptake heterogeneity; some of them may be associated with tumor progression. Fourteen patients with HGG and suspected of PSP underwent FET-PET imaging. A set of 19 conventional and textural FET-PET features were evaluated and subjected to unsupervised consensus clustering. The final diagnosis of true progression vs. PSP was based on follow-up MRI using RANO criteria. Three robust clusters have been identified based on 10 predominantly textural FET-PET features. None of the patients with PSP fell into cluster 2, which was associated with high values for textural FET-PET markers of uptake heterogeneity. Three out of 4 patients with PSP were assigned to cluster 3 that was largely associated with low values of textural FET-PET features. By comparison, tumor-to-normal brain ratio (TNRmax) at the optimal cutoff 2.1 was less predictive of PSP (negative predictive value 57% for detecting true progression, p=0.07 vs. 75% with cluster 3, p=0.04). Clustering based on textural O-(2-[18F]fluoroethyl)-L-tyrosine PET features may provide valuable information in assessing the elusive phenomenon of pseudoprogression.
Chúng tôi nói tiếng Viá»t! (We Speak Vietnamese)
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Pet ownership among persons with AIDS in three Florida counties.
Conti, L; Lieb, S; Liberti, T; Wiley-Bayless, M; Hepburn, K; Diaz, T
1995-11-01
Interviews were conducted among 408 adults with acquired immunodeficiency syndrome at three local health departments to determine the proportion who owned pets, their perceived attachment to their pets, and the proportion who were informed about zoonoses. Nearly half (187, or 46%) were living with pets, most commonly dogs (64%), followed by cats (38%), fish (15%), birds (8%), reptiles (3%), and rodents (2%). Most pet owners (81%) reported an attachment to their pet. Only 10% were informed of zoonoses, albeit some incorrectly. Health care providers should recognize the high pet ownership rate among persons infected with human immunodeficiency virus and correctly inform their patients of strategies to sustain a low zoonotic disease incidence.
Increasing Northern Hemisphere water deficit
McCabe, Gregory J.; Wolock, David M.
2015-01-01
A monthly water-balance model is used with CRUTS3.1 gridded monthly precipitation and potential evapotranspiration (PET) data to examine changes in global water deficit (PET minus actual evapotranspiration) for the Northern Hemisphere (NH) for the years 1905 through 2009. Results show that NH deficit increased dramatically near the year 2000 during both the cool (October through March) and warm (April through September) seasons. The increase in water deficit near 2000 coincides with a substantial increase in NH temperature and PET. The most pronounced increases in deficit occurred for the latitudinal band from 0 to 40°N. These results indicate that global warming has increased the water deficit in the NH and that the increase since 2000 is unprecedented for the 1905 through 2009 period. Additionally, coincident with the increase in deficit near 2000, mean NH runoff also increased due to increases in P. We explain the apparent contradiction of concurrent increases in deficit and increases in runoff.
Determination of the δ15N of nitrate in water; RSIL lab code 2899
Coplen, Tyler B.; Qi, Haiping; Revesz, Kinga; Casciotti, Karen; Hannon, Janet E.
2007-01-01
The purpose of the Reston Stable Isotope Laboratory (RSIL) lab code 2899 is to determine the δ15N of nitrate (NO3-) in water. The δ15N of the dissolved NO3- is analyzed by conversion of the NO3- to nitrous oxide (N2O), which serves as the analyte for mass spectrometry. A culture of denitrifying bacteria is used in the enzymatic conversion of the NO3- to N2O, which follows the pathway shown in equation 1: NO3- → NO2- → NO → 1/2 N2O (1) Because the bacteria Pseudomonas aureofaciens lack N2O reductive activity, the reaction stops at N2O, unlike the typical denitrification reaction that goes to N2. After several hours, the conversion is complete, and the N2O is extracted from the vial, separated from volatile organic vapor and water vapor by an automated -65 °C isopropanol-slush trap, a Nafion drier, a CO2 and water removal unit (Costech #021020 carbon dioxide absorbent with Mg(ClO4)2), and trapped in a small-volume trap immersed in liquid nitrogen with a modified Finnigan MAT (now Thermo Scientific) GasBench 2 introduction system. After the N2O is released, it is further purified by gas chromatography before introduction to the isotope-ratio mass spectrometer (IRMS). The IRMS is a Thermo Scientific Delta V Plus continuous flow IRMS (CF-IRMS). It has a universal triple collector, consisting of two wide cups with a narrow cup in the middle; it is capable of simultaneously measuring mass/charge (m/z) of the N2O molecule 44, 45, and 46. The ion beams from these m/z values are as follows: m/z = 44 = N2O = 14N14N16O; m/z = 45 = N2O = 14N15N16O or 14N14N17O; m/z = 46 = N2O = 14N14N18O. The 17O contributions to the m/z 44 and m/z 45 ion beams are accounted for before δ15N values are reported.
Simultaneous determination of dynamic cardiac metabolism and function using PET/MRI.
Barton, Gregory P; Vildberg, Lauren; Goss, Kara; Aggarwal, Niti; Eldridge, Marlowe; McMillan, Alan B
2018-05-01
Cardiac metabolic changes in heart disease precede overt contractile dysfunction. However, metabolism and function are not typically assessed together in clinical practice. The purpose of this study was to develop a cardiac positron emission tomography/magnetic resonance (PET/MR) stress test to assess the dynamic relationship between contractile function and metabolism in a preclinical model. Following an overnight fast, healthy pigs (45-50 kg) were anesthetized and mechanically ventilated. 18 F-fluorodeoxyglucose ( 18 F-FDG) solution was administered intravenously at a constant rate of 0.01 mL/s for 60 minutes. A cardiac PET/MR stress test was performed using normoxic gas (F I O 2 = .209) and hypoxic gas (F I O 2 = .12). Simultaneous cardiac imaging was performed on an integrated 3T PET/MR scanner. Hypoxic stress induced a significant increase in heart rate, cardiac output, left ventricular (LV) ejection fraction (EF), and peak torsion. There was a significant decline in arterial SpO 2 , LV end-diastolic and end-systolic volumes in hypoxia. Increased LV systolic function was coupled with an increase in myocardial FDG uptake (Ki) during hypoxic stress. PET/MR with continuous FDG infusion captures dynamic changes in both cardiac metabolism and contractile function. This technique warrants evaluation in human cardiac disease for assessment of subtle functional and metabolic abnormalities.
Environmental impacts of food consumption by dogs and cats
2017-01-01
In the US, there are more than 163 million dogs and cats that consume, as a significant portion of their diet, animal products and therefore potentially constitute a considerable dietary footprint. Here, the energy and animal-derived product consumption of these pets in the US is evaluated for the first time, as are the environmental impacts from the animal products fed to them, including feces production. In the US, dogs and cats consume about 19% ± 2% of the amount of dietary energy that humans do (203 ± 15 PJ yr-1 vs. 1051 ± 9 PJ yr-1) and 33% ± 9% of the animal-derived energy (67 ± 17 PJ yr-1 vs. 206 ± 2 PJ yr-1). They produce about 30% ± 13%, by mass, as much feces as Americans (5.1 ± Tg yr-1 vs. 17.2 Tg yr-1), and through their diet, constitute about 25–30% of the environmental impacts from animal production in terms of the use of land, water, fossil fuel, phosphate, and biocides. Dog and cat animal product consumption is responsible for release of up to 64 ± 16 million tons CO2-equivalent methane and nitrous oxide, two powerful greenhouse gasses (GHGs). Americans are the largest pet owners in the world, but the tradition of pet ownership in the US has considerable costs. As pet ownership increases in some developing countries, especially China, and trends continue in pet food toward higher content and quality of meat, globally, pet ownership will compound the environmental impacts of human dietary choices. Reducing the rate of dog and cat ownership, perhaps in favor of other pets that offer similar health and emotional benefits would considerably reduce these impacts. Simultaneous industry-wide efforts to reduce overfeeding, reduce waste, and find alternative sources of protein will also reduce these impacts. PMID:28767700
Environmental impacts of food consumption by dogs and cats.
Okin, Gregory S
2017-01-01
In the US, there are more than 163 million dogs and cats that consume, as a significant portion of their diet, animal products and therefore potentially constitute a considerable dietary footprint. Here, the energy and animal-derived product consumption of these pets in the US is evaluated for the first time, as are the environmental impacts from the animal products fed to them, including feces production. In the US, dogs and cats consume about 19% ± 2% of the amount of dietary energy that humans do (203 ± 15 PJ yr-1 vs. 1051 ± 9 PJ yr-1) and 33% ± 9% of the animal-derived energy (67 ± 17 PJ yr-1 vs. 206 ± 2 PJ yr-1). They produce about 30% ± 13%, by mass, as much feces as Americans (5.1 ± Tg yr-1 vs. 17.2 Tg yr-1), and through their diet, constitute about 25-30% of the environmental impacts from animal production in terms of the use of land, water, fossil fuel, phosphate, and biocides. Dog and cat animal product consumption is responsible for release of up to 64 ± 16 million tons CO2-equivalent methane and nitrous oxide, two powerful greenhouse gasses (GHGs). Americans are the largest pet owners in the world, but the tradition of pet ownership in the US has considerable costs. As pet ownership increases in some developing countries, especially China, and trends continue in pet food toward higher content and quality of meat, globally, pet ownership will compound the environmental impacts of human dietary choices. Reducing the rate of dog and cat ownership, perhaps in favor of other pets that offer similar health and emotional benefits would considerably reduce these impacts. Simultaneous industry-wide efforts to reduce overfeeding, reduce waste, and find alternative sources of protein will also reduce these impacts.
Warnock, Geoffrey; Sommerauer, Michael; Mu, Linjing; Pla Gonzalez, Gloria; Geistlich, Susanne; Treyer, Valerie; Schibli, Roger; Buck, Alfred; Krämer, Stefanie D; Ametamey, Simon M
2018-06-01
Non-invasive imaging of metabotropic glutamate receptor 5 (mGlu 5 ) in the brain using PET is of interest in e.g., anxiety, depression, and Parkinson's disease. Widespread application of the most widely used mGlu 5 tracer, [ 11 C]ABP688, is limited by the short physical half-life of carbon-11. [ 18 F]PSS232 is a fluorinated analog with promising preclinical properties and high selectivity and specificity for mGlu 5 . In this first-in-man study, we evaluated the brain uptake pattern and kinetics of [ 18 F]PSS232 in healthy volunteers. [ 18 F]PSS232 PET was performed with ten healthy male volunteers aged 20-40 years. Seven of the subjects received a bolus injection and the remainder a bolus/infusion protocol. Cerebral blood flow was determined in seven subjects using [ 15 O]water PET. Arterial blood activity was measured using an online blood counter. Tracer kinetics were evaluated by compartment modeling and parametric maps were generated for both tracers. At 90 min post-injection, 59.2 ± 11.1% of total radioactivity in plasma corresponded to intact tracer. The regional first pass extraction fraction of [ 18 F]PSS232 ranged from 0.41 ± 0.06 to 0.55 ± 0.03 and brain distribution pattern matched that of [ 11 C]ABP688. Uptake kinetics followed a simple two-tissue compartment model. The volume of distribution of total tracer (V T , ml/cm 3 ) ranged from 1.18 ± 0.20 for white matter to 2.91 ± 0.51 for putamen. The respective mean distribution volume ratios (DVR) with cerebellum as the reference tissue were 0.88 ± 0.06 and 2.12 ± 0.10, respectively. The tissue/cerebellum ratios of a bolus/infusion protocol (30/70 dose ratio) were close to the DVR values. Brain uptake of [ 18 F]PSS232 matched the distribution of mGlu 5 and followed a two-tissue compartment model. The well-defined kinetics and the possibility to use reference tissue models, obviating the need for arterial blood sampling, make [ 18 F]PSS232 a promising fluorine-18 labeled radioligand for measuring mGlu 5 density in humans.
Barthélémy, E; Spyropoulos, D; Milana, M-R; Pfaff, K; Gontard, N; Lampi, E; Castle, L
2014-01-01
The development of a scheme for the safety evaluation of mechanical recycling processes for polyethylene terephthalate (PET) is described. The starting point is the adoption of a threshold of toxicological concern such that migration from the recycled PET should not give rise to a dietary exposure exceeding 0.0025 μg kg(-1) bw day(-1), the exposure threshold value for chemicals with structural alerts raising concern for potential genotoxicity, below which the risk to human health would be negligible. It is practically impossible to test every batch of incoming recovered PET and every production batch of recycled PET for all the different chemical contaminants that could theoretically arise. Consequently, the principle of the safety evaluation is to measure the cleaning efficiency of a recycling process by using a challenge test with surrogate contaminants. This cleaning efficiency is then applied to reduce a reference contamination level for post-consumer PET, conservatively set at 3 mg kg(-1) PET for a contaminant resulting from possible misuse by consumers. The resulting residual concentration of each contaminant in recycled PET is used in conservative migration models to calculate migration levels, which are then used along with food consumption data to give estimates of potential dietary exposure. The default scenario, when the recycled PET is intended for general use, is that of an infant weighing 5 kg and consuming every day powdered infant formula reconstituted with 0.75 L of water coming from water bottles manufactured with 100% recycled PET. According to this scenario, it can be derived that the highest concentration of a substance in water that would ensure that the dietary exposure of 0.0025 µg kg(-1) bw day(-1) is not exceeded, is 0.017 μg kg(-1) food. The maximum residual content that would comply with this migration limit depends on molecular weight and is in the range 0.09-0.32 mg kg(-1) PET for the typical surrogate contaminants.
Welle, F; Franz, R
2011-01-01
Plastics bottles made from polyethylene terephthalate (PET) are increasingly used for soft drinks, mineral water, juices and beer. In this study a literature review is presented concerning antimony levels found both in PET materials as well as in foods and food simulants. On the other hand, 67 PET samples from the European bottle market were investigated for their residual antimony concentrations. A mean value of 224 ± 32 mg kg(-1) was found, the median was 220 mg kg(-1). Diffusion coefficients for antimony in PET bottle materials were experimentally determined at different temperature between 105 and 150°C. From these data, the activation energy of diffusion for antimony species from the PET bottle wall into beverages and food simulants was calculated. The obtained value of 189 kJ mol(-1) was found to be in good agreement with published data on PET microwave trays (184 kJ mol(-1)). Based on these results, the migration of antimony into beverages was predicted by mathematical migration modelling for different surface/volume ratios and antimony bottle wall concentrations. The results were compared with literature data as well as international legal limits and guidelines values for drinking water and the migration limit set from food packaging legislation. It was concluded that antimony levels in beverages due to migration from PET bottles manufactured according to the state of the art can never reach or exceed the European-specific migration limit of 40 microg kg(-1). Maximum migration levels caused by room-temperature storage even after 3 years will never be essentially higher than 2.5 microg kg(-1) and in any case will be below the European limit of 5 microg kg(-1) for drinking water. The results of this study confirm that the exposure of the consumer by antimony migration from PET bottles into beverages and even into edible oils reaches approximately 1% of the current tolerable daily intake (TDI) established by World Health Organisation (WHO). Having substantiated such low antimony levels in PET-bottled beverages, the often addressed question on oestrogenic effects caused by antimony from PET bottles appears to be groundless.
Microbial diversity and potential pathogens in ornamental fish aquarium water.
Smith, Katherine F; Schmidt, Victor; Rosen, Gail E; Amaral-Zettler, Linda
2012-01-01
Ornamental fishes are among the most popular and fastest growing categories of pets in the United States (U.S.). The global scope and scale of the ornamental fish trade and growing popularity of pet fish in the U.S. are strong indicators of the myriad economic and social benefits the pet industry provides. Relatively little is known about the microbial communities associated with these ornamental fishes or the aquarium water in which they are transported and housed. Using conventional molecular approaches and next generation high-throughput amplicon sequencing of 16S ribosomal RNA gene hypervariable regions, we characterized the bacterial community of aquarium water containing common goldfish (Carassius auratus) and Chinese algae eaters (Gyrinocheilus aymonieri) purchased from seven pet/aquarium shops in Rhode Island and identified the presence of potential pathogens. Our survey identified a total of 30 phyla, the most common being Proteobacteria (52%), Bacteroidetes (18%) and Planctomycetes (6%), with the top four phyla representing >80% of all sequences. Sequences from our water samples were most closely related to eleven bacterial species that have the potential to cause disease in fishes, humans and other species: Coxiella burnetii, Flavobacterium columnare, Legionella birminghamensis, L. pneumophila, Vibrio cholerae, V. mimicus. V. vulnificus, Aeromonas schubertii, A. veronii, A. hydrophila and Plesiomonas shigelloides. Our results, combined with evidence from the literature, suggest aquarium tank water harboring ornamental fish are an understudied source for novel microbial communities and pathogens that pose potential risks to the pet industry, fishes in trade, humans and other species.
Streamflow Impacts of Biofuel Policy-Driven Landscape Change
Khanal, Sami; Anex, Robert P.; Anderson, Christopher J.; Herzmann, Daryl E.
2014-01-01
Likely changes in precipitation (P) and potential evapotranspiration (PET) resulting from policy-driven expansion of bioenergy crops in the United States are shown to create significant changes in streamflow volumes and increase water stress in the High Plains. Regional climate simulations for current and biofuel cropping system scenarios are evaluated using the same atmospheric forcing data over the period 1979–2004 using the Weather Research Forecast (WRF) model coupled to the NOAH land surface model. PET is projected to increase under the biofuel crop production scenario. The magnitude of the mean annual increase in PET is larger than the inter-annual variability of change in PET, indicating that PET increase is a forced response to the biofuel cropping system land use. Across the conterminous U.S., the change in mean streamflow volume under the biofuel scenario is estimated to range from negative 56% to positive 20% relative to a business-as-usual baseline scenario. In Kansas and Oklahoma, annual streamflow volume is reduced by an average of 20%, and this reduction in streamflow volume is due primarily to increased PET. Predicted increase in mean annual P under the biofuel crop production scenario is lower than its inter-annual variability, indicating that additional simulations would be necessary to determine conclusively whether predicted change in P is a response to biofuel crop production. Although estimated changes in streamflow volume include the influence of P change, sensitivity results show that PET change is the significantly dominant factor causing streamflow change. Higher PET and lower streamflow due to biofuel feedstock production are likely to increase water stress in the High Plains. When pursuing sustainable biofuels policy, decision-makers should consider the impacts of feedstock production on water scarcity. PMID:25289698
Fat-constrained 18F-FDG PET reconstruction using Dixon MR imaging and the origin ensemble algorithm
NASA Astrophysics Data System (ADS)
Wülker, Christian; Heinzer, Susanne; Börnert, Peter; Renisch, Steffen; Prevrhal, Sven
2015-03-01
Combined PET/MR imaging allows to incorporate the high-resolution anatomical information delivered by MRI into the PET reconstruction algorithm for improvement of PET accuracy beyond standard corrections. We used the working hypothesis that glucose uptake in adipose tissue is low. Thus, our aim was to shift 18F-FDG PET signal into image regions with a low fat content. Dixon MR imaging can be used to generate fat-only images via the water/fat chemical shift difference. On the other hand, the Origin Ensemble (OE) algorithm, a novel Markov chain Monte Carlo method, allows to reconstruct PET data without the use of forward- and back projection operations. By adequate modifications to the Markov chain transition kernel, it is possible to include anatomical a priori knowledge into the OE algorithm. In this work, we used the OE algorithm to reconstruct PET data of a modified IEC/NEMA Body Phantom simulating body water/fat composition. Reconstruction was performed 1) natively, 2) informed with the Dixon MR fat image to down-weight 18F-FDG signal in fatty tissue compartments in favor of adjacent regions, and 3) informed with the fat image to up-weight 18F-FDG signal in fatty tissue compartments, for control purposes. Image intensity profiles confirmed the visibly improved contrast and reduced partial volume effect at water/fat interfaces. We observed a 17+/-2% increased SNR of hot lesions surrounded by fat, while image quality was almost completely retained in fat-free image regions. An additional in vivo experiment proved the applicability of the presented technique in practice, and again verified the beneficial impact of fat-constrained OE reconstruction on PET image quality.
The MINDView brain PET detector, feasibility study based on SiPM arrays
NASA Astrophysics Data System (ADS)
González, Antonio J.; Majewski, Stan; Sánchez, Filomeno; Aussenhofer, Sebastian; Aguilar, Albert; Conde, Pablo; Hernández, Liczandro; Vidal, Luis F.; Pani, Roberto; Bettiol, Marco; Fabbri, Andrea; Bert, Julien; Visvikis, Dimitris; Jackson, Carl; Murphy, John; O'Neill, Kevin; Benlloch, Jose M.
2016-05-01
The Multimodal Imaging of Neurological Disorders (MINDView) project aims to develop a dedicated brain Positron Emission Tomography (PET) scanner with sufficient resolution and sensitivity to visualize neurotransmitter pathways and their disruptions in mental disorders for diagnosis and follow-up treatment. The PET system should be compact and fully compatible with a Magnetic Resonance Imaging (MRI) device in order to allow its operation as a PET brain insert in a hybrid imaging setup with most MRI scanners. The proposed design will enable the currently-installed MRI base to be easily upgraded to PET/MRI systems. The current design for the PET insert consists of a 3-ring configuration with 20 modules per ring and an axial field of view of ~15 cm and a geometrical aperture of ~33 cm in diameter. When coupled to the new head Radio Frequency (RF) coil, the inner usable diameter of the complete PET-RF coil insert is reduced to 26 cm. Two scintillator configurations have been tested, namely a 3-layer staggered array of LYSO with 1.5 mm pixel size, with 35×35 elements (6 mm thickness each) and a black-painted monolithic LYSO block also covering about 50×50 mm2 active area with 20 mm thickness. Laboratory test results associated with the current MINDView PET module concept are presented in terms of key parameters' optimization, such as spatial and energy resolution, sensitivity and Depth of Interaction (DOI) capability. It was possible to resolve all pixel elements from the three scintillator layers with energy resolutions as good as 10%. The monolithic scintillator showed average detector resolutions varying from 3.5 mm in the entrance layer to better than 1.5 mm near the photosensor, with average energy resolutions of about 17%.
Zhang, Xiang; Zhao, Jianwen; Dou, Junyan; Tange, Masayoshi; Xu, Weiwei; Mo, Lixin; Xie, Jianjun; Xu, Wenya; Ma, Changqi; Okazaki, Toshiya; Cui, Zheng
2016-09-01
P-type and n-type top-gate carbon nanotube thin-film transistors (TFTs) can be selectively and simultaneously fabricated on the same polyethylene terephthalate (PET) substrate by tuning the types of polymer-sorted semiconducting single-walled carbon nanotube (sc-SWCNT) inks, along with low temperature growth of HfO 2 thin films as shared dielectric layers. Both the p-type and n-type TFTs show good electrical properties with on/off ratio of ≈10 5 , mobility of ≈15 cm 2 V -1 s -1 , and small hysteresis. Complementary metal oxide semiconductor (CMOS)-like logic gates and circuits based on as-prepared p-type and n-type TFTs have been achieved. Flexible CMOS-like inverters exhibit large noise margin of 84% at low voltage (1/2 V dd = 1.5 V) and maximum voltage gain of 30 at V dd of 1.5 V and low power consumption of 0.1 μW. Both of the noise margin and voltage gain are one of the best values reported for flexible CMOS-like inverters at V dd less than 2 V. The printed CMOS-like inverters work well at 10 kHz with 2% voltage loss and delay time of ≈15 μs. A 3-stage ring oscillator has also been demonstrated on PET substrates and the oscillation frequency of 3.3 kHz at V dd of 1 V is achieved. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Montuori, P; Jover, E; Morgantini, M; Bayona, J M; Triassi, M
2008-04-01
Phthalic acid and phthalate esters are of growing interest due to their significant usage and potential toxicity. Polyethylene terephthalate (PET) and glass are both widely used materials for bottled drinking water. In this study, phthalic acid (PhA), bis(2-ethylhexyl) phthalate (DEHP), dimethyl phthalate (DMP), diethyl phthalate (DEP), diisobutyl phthalate (DiisoBP) and dibutyl phthalate (DBP) were analysed in a large number of Italian bottled water samples. These samples showed different concentrations of phthalates are nearly 20 times higher in samples bottled in PET than those from glass bottles with total levels of phthalates of 3.52 and 0.19 microg l(-1), respectively. However, the observed levels do not represent a significant exposure pathway when considering the US Environmental Protection Agency (USEPA) reference dose (an estimate of a daily oral exposure to the human population, including sensitive subgroups, that is likely to be without an appreciable risk of deleterious effects during a lifetime). In addition, no significant correlation was found between the phthalate concentrations and the physicochemical properties of the different water samples, apart from the still/sparkling water parameter for the PET samples. In this instance, slightly higher concentrations were observed for the PET bottled still water samples than for the sparkling water samples, although no explanation has been found yet.
Investigation of Listeria, Salmonella, and toxigenic Escherichia coli in various pet foods.
Nemser, Sarah M; Doran, Tara; Grabenstein, Michael; McConnell, Terri; McGrath, Timothy; Pamboukian, Ruiqing; Smith, Angele C; Achen, Maya; Danzeisen, Gregory; Kim, Sun; Liu, Yong; Robeson, Sharon; Rosario, Grisel; McWilliams Wilson, Karen; Reimschuessel, Renate
2014-09-01
The Veterinary Laboratory Investigation and Response Network (Vet-LIRN), in collaboration with the Food Emergency Response Network (FERN) and its Microbiology Cooperative Agreement Program (MCAP) laboratories, conducted a study to evaluate the prevalence of selected microbial organisms in various types of pet foods. The goal of this blinded study was to help the Center for Veterinary Medicine prioritize potential future pet food-testing efforts. The study also increased the FERN laboratories' screening capabilities for foodborne pathogens in animal feed matrices, since such pathogens may also be a significant health risk to consumers who come into contact with pet foods. Six U.S. Food and Drug Administration FERN MCAP laboratories analyzed approximately 1056 samples over 2 years. Laboratories tested for Salmonella, Listeria, Escherichia coli O157:H7 enterohemorrhagic E. coli, and Shiga toxin-producing strains of E. coli (STEC). Dry and semimoist dog and cat foods purchased from local stores were tested during Phase 1. Raw dog and cat foods, exotic animal feed, and jerky-type treats purchased through the Internet were tested in Phase 2. Of the 480 dry and semimoist samples, only 2 tested positive: 1 for Salmonella and 1 for Listeria greyii. However, of the 576 samples analyzed during Phase 2, 66 samples were positive for Listeria (32 of those were Listeria monocytogenes) and 15 samples positive for Salmonella. These pathogens were isolated from raw foods and jerky-type treats, not the exotic animal dry feeds. This study showed that raw pet foods may harbor food safety pathogens, such as Listeria monocytogenes and Salmonella. Consumers should handle these products carefully, being mindful of the potential risks to human and animal health.
A PET Prototype for “In-Beam” Monitoring of Proton Therapy
NASA Astrophysics Data System (ADS)
Vecchio, Sara; Attanasi, Francesca; Belcari, Nicola; Camarda, Manuela; Cirrone, G. A. Pablo; Cuttone, Giacomo; Di Rosa, Francesco; Lanconelli, Nico; Moehrs, Sascha; Rosso, Valeria; Russo, Giorgio; Del Guerra, Alberto
2009-02-01
The in-beam PET is a novel PET application to image the beta+ activity induced in biological tissues by hadronic therapeutic beams. Thanks to the correlation existing between beam-delivered dose profiles and beam-induced activity profiles, in vivo information about the effective ion paths can be extracted from the in-beam pet image. in situ measurements, immediately after patient irradiation, are recommended in order to exploit the maximum statistics, by also detecting the contribution provided by the very short lived isotopes, e.g. 15O. A compact, dedicated tomograph should then be developed for such an application, so as to be used in the treatment room. We developed a small PET prototype in order to demonstrate the feasibility of such a technique for the monitoring of proton therapy of ocular tumors at the CATANA facility (Catania, Italy). The prototype consists of two planar heads with an active area of about 5 cm times 5 cm. Each head is made up of a square position sensitive photomultiplier (Hamamatsu H8500) coupled to a matrix of the same size of LYSO scintillating crystals (2 mm times 2 mm times 18 mm pixel dimensions). Dedicated, compact electronic boards are used for the signal multiplexing, amplification and digitization. The distance between the pair can be varied from 10 cm up to a maximum of about 20 cm. The validation of the prototype was performed on plastic phantoms using 62 MeV protons at the CATANA beam line. Different dose distributions were delivered and a good correlation between the distal fall-off of the activity profiles and of the dose profiles was found, i.e., better than 2 mm along the beam direction.
SU-E-I-81: Targeting of HER2-Expressing Tumors with Dual PET-MR Imaging Probes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, P; Peng, Y; Sun, M
2015-06-15
Purpose: The detection of human epidermal growth factor receptor type 2 (HER2) expression in malignant tumors provides important information influencing patient management. Radionuclide in vivo imaging of HER2 may permit the detection of HER2 in both primary tumors and metastases by a single noninvasive procedure. Trastuzumab, effective in about 15 % of women with breast cancer, downregulates signalling through the Akt/PI3K and MAPK pathways.These pathways modulate metabolism which can be monitored by positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: The relationship between response of HER2 overexpressing tumours and changes in imaging PET or SPECT and MRI willmore » be examined by a integrated bimodal imaging probe.Small (7 kDa) high-affinity anti-HER2 Affibody molecules and KCCYSL targeting peptide may be suitable tracers for visualization of HER2-expressing tumors. Peptide-conjugated iron oxide nanoparticles (Fe3O4 NPs) as MRI imaging and CB-TE2A as PET imaging are integrated into a single synthetic molecule in the HER2 positive cancer. Results: One of targeted contrast bimodal imaging probe agents was synthesized and evaluated to target HER2-expressing tumors in a HER2 positive rat model. We will report the newest results regarding the development of bimodal imaging probes. Conclusion: The preliminary results of the bimodal imaging probe presents high correlation of MRI signal and PET imaging intensity in vivo. This unique feature can hardly be obtained by single model contrast agents. It is envisioned that this bimodal agents can hold great potential for accurate detection of HER2-expressing tumors which are critical for clinical management of the disease.« less
Investigation of Listeria, Salmonella, and Toxigenic Escherichia coli in Various Pet Foods
Doran, Tara; Grabenstein, Michael; McConnell, Terri; McGrath, Timothy; Pamboukian, Ruiqing; Smith, Angele C.; Achen, Maya; Danzeisen, Gregory; Kim, Sun; Liu, Yong; Robeson, Sharon; Rosario, Grisel; McWilliams Wilson, Karen; Reimschuessel, Renate
2014-01-01
Abstract The Veterinary Laboratory Investigation and Response Network (Vet-LIRN), in collaboration with the Food Emergency Response Network (FERN) and its Microbiology Cooperative Agreement Program (MCAP) laboratories, conducted a study to evaluate the prevalence of selected microbial organisms in various types of pet foods. The goal of this blinded study was to help the Center for Veterinary Medicine prioritize potential future pet food–testing efforts. The study also increased the FERN laboratories' screening capabilities for foodborne pathogens in animal feed matrices, since such pathogens may also be a significant health risk to consumers who come into contact with pet foods. Six U.S. Food and Drug Administration FERN MCAP laboratories analyzed approximately 1056 samples over 2 years. Laboratories tested for Salmonella, Listeria, Escherichia coli O157:H7 enterohemorrhagic E. coli, and Shiga toxin–producing strains of E. coli (STEC). Dry and semimoist dog and cat foods purchased from local stores were tested during Phase 1. Raw dog and cat foods, exotic animal feed, and jerky-type treats purchased through the Internet were tested in Phase 2. Of the 480 dry and semimoist samples, only 2 tested positive: 1 for Salmonella and 1 for Listeria greyii. However, of the 576 samples analyzed during Phase 2, 66 samples were positive for Listeria (32 of those were Listeria monocytogenes) and 15 samples positive for Salmonella. These pathogens were isolated from raw foods and jerky-type treats, not the exotic animal dry feeds. This study showed that raw pet foods may harbor food safety pathogens, such as Listeria monocytogenes and Salmonella. Consumers should handle these products carefully, being mindful of the potential risks to human and animal health. PMID:24824368
Retail lighting and packaging influence consumer acceptance of fluid milk.
Potts, H L; Amin, K N; Duncan, S E
2017-01-01
Little is known about the effect of retail light-emitting diode (LED) exposure on consumer acceptance of milk. The study objective was to determine effects of fluorescent and LED lighting under retail storage conditions on consumer acceptance of milk. Consumer acceptance of milk stored under retail conditions was determined through sensory evaluation (2 studies; n=150+ each) and analytical measures (dissolved oxygen, secondary oxidation products, riboflavin retention). Study 1 evaluated milk stored in high-density polyethylene (HDPE) packages for 4h under LED light (960 lx). Commercially available HDPE package treatments included translucent HDPE (most commonly used), white HDPE [low concentration (1.3%) TiO 2 ], and yellow HDPE; in addition, HDPE with a higher TiO 2 concentration (high white; 4.9% TiO 2 ) and a foil-wrapped translucent HDPE (control) were tested. Translucent and control packages also were tested under fluorescent light. Study 2 evaluated polyethylene terephthalate (PET) packages for 4h under fluorescent and LED light (1,460 lx). The PET packaging included 2 treatments (medium, 4.0% TiO 2 ; high, 6.6% TiO 2 ) as well as translucent HDPE (exposed to fluorescent), clear PET (fluorescent and LED), and light-protected control. Overall mean acceptability of milk ranged from "like slightly" to "like moderately" with significantly lower acceptability for milk exposed to fluorescent light. Milk in HDPE and PET packages had comparable overall acceptability scores when exposed to LED light. Only the fluorescent light condition (both PET and HDPE) diminished overall acceptability. Fluorescent light exposure negatively influenced flavor with significant penalty (2.0-2.5 integers) to overall acceptability of milk in translucent HDPE and clear PET. The LED also diminished aftertaste of milk packaged in translucent HDPE. Changes in dissolved oxygen content, as an indication of oxidation, supported the observed differences in consumer acceptance of milk stored under fluorescent and LED light. Consumers like the flavor of fresh milk, which can be protected by selecting appropriate packaging that blocks detrimental light wavelengths. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Pangloli, Philipus; Hung, Yen-Con
2011-08-01
The objective of this study was to evaluate the efficacy of slightly acidic electrolyzed (SAEO) water in killing or removing Escherichia coli O157:H7 on iceberg lettuce and tomatoes by washing and chilling treatment simulating protocols used in food service kitchens. Whole lettuce leaves and tomatoes were spot-inoculated with 100 μL of a mixture of 5 strains of E. coli O157:H7. Washing lettuce with SAEO water for 15 s reduced the pathogen by 1.4 to 1.6 log CFU/leaf, but the treatments did not completely inactivate the pathogen in the wash solution. Increasing the washing time to 30 s increased the reductions to 1.7 to 2.3 log CFU/leaf. Sequential washing in SAEO water for 15 s and then chilling in SAEO water for 15 min also increased the reductions to 2.0 to 2.4 log CFU/leaf, and no cell survived in chilling solution after treatment. Washing tomatoes with SAEO water for 8 s reduced E. coli O157:H7 by 5.4 to 6.3 log CFU/tomato. The reductions were increased to 6.6 to 7.6 log CFU/tomato by increasing the washing time to 15 s. Results suggested that application of SAEO water to wash and chill lettuce and tomatoes in food service kitchens could minimize cross-contamination and reduce the risk of E. coli O157:H7 present on the produce. SAEO water is equally or slightly better than acidic electrolyzed (AEO) water for inactivation of bacteria on lettuce and tomato surfaces. In addition, SAEO water may have the advantages over AEO water on its stability, no chlorine smell, and low corrosiveness. Therefore, SAEO water may have potential for produce wash to enhance food safety. © 2011 Institute of Food Technologists®
NASA Astrophysics Data System (ADS)
Li, Hongxia; Zhou, You; Du, Gang; Huang, Yanwei; Ji, Zhenguo
2018-03-01
Flexible resistance random access memory (ReRAM) devices with a heterojunction structure of PET/ITO/ZnO/TiO2/Au were fabricated on polyethylene terephthalate/indium tin oxide (PET/ITO) substrates by different physical and chemical preparation methods. X-ray diffraction, scanning electron microscopy and atomic force microscopy were carried out to investigate the crystal structure, surface topography and cross-sectional structure of the prepared films. X-ray photoelectron spectroscopy was also used to identify the chemical state of Ti, O and Zn elements. Theoretical and experimental analyses were conducted to identify the effect of piezoelectric potential of ZnO on resistive switching characteristics of flexible ZnO/TiO2 heterojunction cells. The results showed a pathway to enhance the performance of ReRAM devices by engineering the interface barrier, which is also feasible for other electronics, optoelectronics and photovoltaic devices.
Synthesis of [18F]-labelled Maltose Derivatives as PET Tracers for Imaging Bacterial Infection
Namavari, Mohammad; Gowrishankar, Gayatri; Hoehne, Aileen; Jouannot, Erwan; Gambhir, Sanjiv S
2015-01-01
Purpose To develop novel positron emission tomography (PET) agents for visualization and therapy monitoring of bacterial infections. Procedures It is known that maltose and maltodextrins are energy sources for bacteria. Hence, 18F-labelled maltose derivatives could be a valuable tool for imaging bacterial infections. We have developed methods to synthesize 4-O-(α-D-glucopyranosyl)-6-deoxy-6-[18F]fluoro-D-glucopyranoside (6-[18F]fluoromaltose) and 4-O-(α-D-glucopyranosyl)-1-deoxy-1-[18F]fluoro-D-glucopyranoside (1-[18F]fluoromaltose) as bacterial infection PET imaging agents. 6-[18F]fluoromaltose was prepared from precursor 1,2,3-tri-O-acetyl-4-O-(2′,3′,-di-O-acetyl-4′,6′-benzylidene-α-D-glucopyranosyl)-6-deoxy-6-nosyl-D-glucopranoside (5). The synthesis involved the radio-fluorination of 5 followed by acidic and basic hydrolysis to give 6-[18F]fluoromaltose. In an analogous procedure, 1-[18F]fluoromaltose was synthesized from 2,3, 6-tri-O-acetyl-4-O-(2′,3′,4′,6-tetra-O-acetyl-α-D-glucopyranosyl)-1-deoxy-1-O-triflyl-D-glucopranoside (9). Stability of 6-[18F]fluoromaltose in phosphate-buffered saline (PBS) and human and mouse serum at 37 °C was determined. Escherichia coli uptake of 6-[18F]fluoromaltose was examined. Results A reliable synthesis of 1- and 6-[18F]fluoromaltose has been accomplished with 4–6 and 5–8 % radiochemical yields, respectively (decay-corrected with 95 % radiochemical purity). 6-[18F]fluoromaltose was sufficiently stable over the time span needed for PET studies (~96 % intact compound after 1-h and ~65 % after 2-h incubation in serum). Bacterial uptake experiments indicated that E. coli transports 6-[18F]fluoromaltose. Competition assays showed that the uptake of 6-[18F]fluoromaltose was completely blocked by co-incubation with 1 mM of the natural substrate maltose. Conclusion We have successfully synthesized 1- and 6-[18F]fluoromaltose via direct fluorination of appropriate protected maltose precursors. Bacterial uptake experiments in E. coli and stability studies suggest a possible application of 6-[18F]fluoromaltose as a new PET imaging agent for visualization and monitoring of bacterial infections. PMID:25277604
Zheng, Qi-Huang; Liu, Xuan; Fei, Xiangshu; Wang, Ji-Quan; Ohannesian, David W; Erickson, Leonard C; Stone, K Lee; Hutchins, Gary D
2003-05-01
Novel radiolabeled O(6)-benzylguanine (O(6)-BG) derivatives, 2-amino-6-O-[(11)C]-[(methoxymethyl)benzyloxy]-9-methyl purines ([(11)C]p-O(6)-AMMP, 1a; [(11)C]m-O(6)-AMMP, 1b; [(11)C]o-O(6)-AMMP, 1c), 2-amino-6-O-benzyloxy-9-[(11)C]-[(methoxycarbonyl)methyl]purine ([(11)C]ABMMP, 2), and 2-amino-6-O-benzyloxy-9-[(11)C]-[(4'-methoxycarbonyl)benzyl]purine ([(11)C]ABMBP, 3), have been synthesized for evaluation as new potential positron emission tomography (PET) imaging agents for the DNA repair protein O(6)-alkylguanine-DNA alkyltransferase (AGT) in breast cancer. The appropriate precursors for radiolabeling were obtained in two to three steps from starting material 2-amino-6-chloropurine with moderate to excellent chemical yields. Tracers were prepared by O-[(11)C]methylation of hydroxymethyl or acid precursors using [(11)C]methyl triflate. Pure target compounds were isolated by solid-phase extraction (SPE) purification procedure in 45-65% radiochemical yields (decay corrected to end of bombardment), and a synthesis time of 20-25 min. The activity of unlabeled standard samples of 1-3 was evaluated via an in vitro AGT oligonucleotide assay. Preliminary findings from biological assay indicate the synthesized analogs have similar strong inhibitory effectiveness on AGT in comparison with the parent compound O(6)-BG. The results warrant further evaluation of these radiotracers as new potential PET imaging agents for the DNA repair protein AGT in breast cancer in vivo.
NASA Astrophysics Data System (ADS)
Akrami, N.; Barker, X. Z.; Horwath, W. R.
2017-12-01
Nitrous Oxide (N2O) with global warming potential of 298 over a 100-year horizon is one of the most potent green house gases. In the United States, agriculture share to N2O emissions is over 70%. Peat lands, however, are being considered as both sources and sinks of greenhouse gases. N2O emissions are a product of both production and consumption processes. However, there is still a lack of understanding of N2O consumption processes in soils. In this work, the potential of re-wetted peat lands planted to rice in Sacramento-San Joaquin Delta, California, to act as a potential sink for N2O is being evaluated. Four peat land soils with 1%, 5%, 11% and 23% of organic carbon have been anaerobically incubated with different water contents (15%, 30%, 50%, 75% and 100% of their water holding capacity). 15N-N2O gas has been injected to the headspace of experiment jars and the production and consumption rate of 15N-N2O, 15N-N2 and production rate of Carbon Dioxide (CO2) and Methane (CH4) along with dissolved Nitrate (NO3-), Nitrite (NO2-), Ammonium (NH4+), Iron (II) and Iron (III) concentration has been quantified. Our results show promising N2O consumption rates under high carbon content and relatively high water content treatments. This research introduces organic carbon and water content as two major criteria in N2O consumption processes in peat lands that make it a potential hotspot for climate changes mitigation through adopting effective management practices to decrease greenhouse gas emissions.
Recycled PET Nanofibers for Water Filtration Applications
Zander, Nicole E.; Gillan, Margaret; Sweetser, Daniel
2016-01-01
Water shortage is an immediate and serious threat to our world population. Inexpensive and scalable methods to clean freshwater and wastewater are in high demand. Nanofiber filtration membranes represent a next generation nonwoven filter media due to their unique properties. Polyethlyene terephthalate (PET) is often used in the packaging of water and other commonly used materials, leading to a large amount of plastic waste often with limited incentive for recycling (few value-added uses). Here, we present work in the generation of nanofiber liquid filtration membranes from PET plastic bottles and demonstrate their use in microfiltration. PET nanofiber membranes were formed via solution electrospinning with fiber diameters as low as ca. 100 nm. Filtration efficiency was tested with latex beads with sizes ranging from 30 to 2000 nm. Greater than 99% of the beads as small as 500 nm were removed using gravity filtration. To reduce biofouling, the mats were functionalized with quaternary ammonium and biguanide biocides. The biguanide functionalized mats achieved 6 log reduction for both gram negative and gram positive bacteria. PMID:28773380
The Effects of Cooking Process and Meat Inclusion on Pet Food Flavor and Texture Characteristics
Koppel, Kadri; Gibson, Michael; Alavi, Sajid; Aldrich, Greg
2014-01-01
Simple Summary The results of this research indicate that processing (baked vs. extruded) plays an important role in determining pet food product texture. In addition, raw ingredients (fresh meat vs. meal-based) did not consistently affect product sensory characteristics. These results may help pet food technologists better understand factors that affect palatability. Abstract The pet food industry is an important portion of the food and feed industries in the US. The objectives of this study were (1) to determine cooking method (baking or extrusion), meat inclusion (0 or 20%), and extrusion thermal to mechanical energy ratios (low, medium, and high) effects on sensory and volatile properties of pet foods, and (2) to determine associations among sensory and volatile characteristics of baked and extruded pet foods. Descriptive sensory analysis and gas chromatography-mass spectrometry were used to analyze the pet food samples. It was found that baked samples were lighter in color (2.0–2.6 baked vs. 3.5–4.3 extruded, color intensity scale 0–15), and had lower levels of attributes that indicated rancidity (i.e., fishy flavor; 0.3–0.6 baked, 0.6–1.5 extruded, scale 0–15), whereas extruded pet foods were more cohesive in mass, more friable, hard, and crisp, but less powdery than baked samples. Fresh meat inclusion tended to decrease bitterness and increase fishy flavor and cohesiveness of pet foods. High thermal to mechanical energy ratio during extrusion resulted in less musty and more porous kibbles. The main volatile compounds included aldehydes, such as hexanal and heptanal, ketones, and alcohols. Extruded samples did not contain methylpyrazine, while baked samples did not contain 2-butyl furan. Future studies should consider evaluating the relationship between sensory results and animal palatability for these types of foods. PMID:26480040
NASA Astrophysics Data System (ADS)
Zheng, Han; Yu, Guirui; Wang, Qiufeng; Zhu, Xianjin; Yan, Junhua; Wang, Huimin; Shi, Peili; Zhao, Fenghua; Li, Yingnian; Zhao, Liang; Zhang, Junhui; Wang, Yanfen
2017-08-01
Estimates of atmospheric evaporative demand have been widely required for a variety of hydrological analyses, with potential evapotranspiration (PET) being an important measure representing evaporative demand of actual vegetated surfaces under given metrological conditions. In this study, we assessed the ability of various PET models in capturing long-term (typically 2003-2011) dynamics of evaporative demand at eight ecosystems across various biomes and climatic regimes in China. Prior to assessing PET dynamics, we first examined the reasonability of fourteen PET models in representing the magnitudes of evaporative demand using eddy-covariance actual evapotranspiration (AET) as an indicator. Results showed that the robustness of the fourteen PET models differed somewhat across the sites, and only three PET models could produce reasonable magnitudes of evaporative demand (i.e., PET ≥ AET on average) for all eight sites, including the: (i) Penman; (ii) Priestly-Taylor and (iii) Linacre models. Then, we assessed the ability of these three PET models in capturing dynamics of evaporative demand by comparing the annual and seasonal trends in PET against the equivalent trends in AET and precipitation (P) for particular sites. Results indicated that nearly all the three PET models could faithfully reproduce the dynamics in evaporative demand for the energy-limited conditions at both annual and seasonal scales, while only the Penman and Linacre models could represent dynamics in evaporative demand for the water-limited conditions. However, the Linacre model was unable to reproduce the seasonal switches between water- and energy-limited states for some sites. Our findings demonstrated that the choice of PET models would be essential for the evaporative demand analyses and other related hydrological analyses at different temporal and spatial scales.
15 CFR 265.43 - Pets and other animals.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 15 Commerce and Foreign Trade 1 2012-01-01 2012-01-01 false Pets and other animals. 265.43 Section... animals. Except in connection with the conduct of official business on the site or with the approval of... person shall bring upon the site any cat, dog, or other animal, provided, however, that blind persons may...
15 CFR 265.43 - Pets and other animals.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Pets and other animals. 265.43 Section... animals. Except in connection with the conduct of official business on the site or with the approval of... person shall bring upon the site any cat, dog, or other animal, provided, however, that blind persons may...
15 CFR 265.43 - Pets and other animals.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 1 2011-01-01 2011-01-01 false Pets and other animals. 265.43 Section... animals. Except in connection with the conduct of official business on the site or with the approval of... person shall bring upon the site any cat, dog, or other animal, provided, however, that blind persons may...
15 CFR 265.43 - Pets and other animals.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 15 Commerce and Foreign Trade 1 2013-01-01 2013-01-01 false Pets and other animals. 265.43 Section... animals. Except in connection with the conduct of official business on the site or with the approval of... person shall bring upon the site any cat, dog, or other animal, provided, however, that blind persons may...
15 CFR 265.43 - Pets and other animals.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 1 2014-01-01 2014-01-01 false Pets and other animals. 265.43 Section... animals. Except in connection with the conduct of official business on the site or with the approval of... person shall bring upon the site any cat, dog, or other animal, provided, however, that blind persons may...
NASA Astrophysics Data System (ADS)
Rehman, Mohammad Mutee ur; Kim, Kwang Tae; Na, Kyoung Hoan; Choi, Kyung Hyun
2017-11-01
In this study, organic polymer poly-vinyl acetate (PVA) and inorganic aluminum oxide (Al2O3) have been used together to fabricate a hybrid barrier thin film for the protection of PET substrate. The organic thin films of PVA were developed through roll to roll electrohydrodynamic atomization (R2R-EHDA) whereas the inorganic thin films of Al2O3 were grown by roll to roll spatial atmospheric atomic layer deposition (R2R-SAALD) for mass production. The use of these two technologies together to develop a multilayer hybrid organic-inorganic barrier thin films under atmospheric conditions is reported for the first time. These multilayer hybrid barrier thin films are fabricated on flexible PET substrate. Each layer of Al2O3 and PVA in barrier thin film exhibited excellent morphological, chemical and optical properties. Extremely uniform and atomically thin films of Al2O3 with average arithmetic roughness (Ra) of 1.64 nm and 1.94 nm respectively concealed the non-uniformity and irregularities in PVA thin films with Ra of 2.9 nm and 3.6 nm respectively. The optical transmittance of each layer was ∼ 80-90% while the water vapor transmission rate (WVTR) of hybrid barrier was in the range of ∼ 2.3 × 10-2 g m-2 day-1 with a total film thickness of ∼ 200 nm. Development of such hybrid barrier thin films with mass production and low cost will allow various flexible electronic devices to operate in atmospheric conditions without degradation of their properties.
Electrical properties of double layer dielectric structures for space technology
NASA Astrophysics Data System (ADS)
Lian, Anqing
1993-04-01
Polymeric films such as polyimide (PI) and polyethylene terephthalate (PET) are used in space technology as thermal blankets. Thin SiO2 and SiN coatings plasma deposited onto PI and PET surfaces were proposed to protect the blanket materials against the space environment. The electrical properties of this kind of dual layer dielectric structure were investigated to understand the mechanisms for suppressing charge accumulation and flashover. Bulk and surface electrical conductivities of thin single-layer PI and PET samples and of the dual layer SiO2 and SiN combinations with PI and PET were measured in a range of applied electrical fields. The capacitance voltage (CV) technique was used for analyzing charge transport and distribution in the structures. The electric current in the bulk of the SiO2/PI and SiN/PI samples was found to depend on the polarity of the electric field. Other samples did not exhibit any such polarity effect. The polarity dependence is attributed to charge trapping at the PI/plasma deposit interface. The CV characteristics of the Al-PI-SiO2-Si structure confirm that charges which can modify the local electric field can be trapped near the interface. A model is proposed to interpret the properties of the currents in dual layer structures. This model can semi-quantitatively explain all the observed results.
ODM2 (Observation Data Model): The EarthChem Use Case
NASA Astrophysics Data System (ADS)
Lehnert, Kerstin; Song, Lulin; Hsu, Leslie; Horsburgh, Jeffrey S.; Aufdenkampe, Anthony K.; Mayorga, Emilio; Tarboton, David; Zaslavsky, Ilya
2014-05-01
PetDB is an online data system that was created in the late 1990's to serve online a synthesis of published geochemical and petrological data of igneous and metamorphic rocks. PetDB has today reached a volume of 2.5 million analytical values for nearly 70,000 rock samples. PetDB's data model (Lehnert et al., G-Cubed 2000) was designed to store sample-based observational data generated by the analysis of rocks, together with a wide range of metadata documenting provenance of the samples, analytical procedures, data quality, and data source. Attempts to store additional types of geochemical data such as time-series data of seafloor hydrothermal springs and volcanic gases, depth-series data for marine sediments and soils, and mineral or mineral inclusion data revealed the limitations of the schema: the inability to properly record sample hierarchies (for example, a garnet that is included in a diamond that is included in a xenolith that is included in a kimberlite rock sample), inability to properly store time-series data, inability to accommodate classification schemes other than rock lithologies, deficiencies of identifying and documenting datasets that are not part of publications. In order to overcome these deficiencies, PetDB has been developing a new data schema using the ODM2 information model (ODM=Observation Data Model). The development of ODM2 is a collaborative project that leverages the experience of several existing information representations, including PetDB and EarthChem, and the CUAHSI HIS Observations Data Model (ODM), as well as the general specification for encoding observational data called Observations and Measurements (O&M) to develop a uniform information model that seamlessly manages spatially discrete, feature-based earth observations from environmental samples and sample fractions as well as in-situ sensors, and to test its initial implementation in a variety of user scenarios. The O&M model, adopted as an international standard by the Open Geospatial Consortium, and later by ISO, is the foundation of several domain markup languages such as OGC WaterML 2, used for exchanging hydrologic time series. O&M profiles for samples and sample fractions have not been standardized yet, and there is a significant variety in sample data representations used across agencies and academic projects. The intent of the ODM2 project is to create a unified relational representation for different types of spatially discrete observational data, ensuring that the data can be efficiently stored, transferred, catalogued and queried within a variety of earth science applications. We will report on the initial design and implementation of the new model for PetDB, and results of testing the model against a set of common queries. We have explored several aspects of the model, including: semantic consistency, validation and integrity checking, portability and maintainability, query efficiency, and scalability. The sample datasets from PetDB have been loaded in the initial physical implementation for testing. The results of the experiments point to both benefits and challenges of the initial design, and illustrate the key trade-off between the generality of design, ease of interpretation, and query efficiency, especially as the system needs to scale to millions of records.
Bradberry, Trent J; Metman, Leonard Verhagen; Contreras-Vidal, José L; van den Munckhof, Pepijn; Hosey, Lara A; Thompson, Jennifer L W; Schulz, Geralyn M; Lenz, Fredrick; Pahwa, Rajesh; Lyons, Kelly E; Braun, Allen R
2012-10-01
Dopamine agonist therapy and deep brain stimulation (DBS) of the subthalamic nucleus (STN) are antiparkinsonian treatments that act on a different part of the basal ganglia-thalamocortical motor circuitry, yet produce similar symptomatic improvements. The purpose of this study was to identify common and unique brain network features of these standard treatments. We analyzed images produced by H(2)(15)O positron emission tomography (PET) of patients with Parkinson's disease (PD) at rest. Nine patients were scanned before and after injection of apomorphine, and 11 patients were scanned while bilateral stimulators were off and while they were on. Both treatments produced common deactivations of the neocortical sensorimotor areas, including the supplementary motor area, precentral gyrus, and postcentral gyrus, and in subcortical structures, including the putamen and cerebellum. We observed concomitant activations of the superior parietal lobule and the midbrain in the region of the substantia nigra/STN. We also detected unique, treatment-specific changes with possible motor-related consequences in the basal ganglia, thalamus, neocortical sensorimotor cortex, and posterolateral cerebellum. Unique changes in nonmotor regions may reflect treatment-specific effects on verbal fluency and limbic functions. Many of the common effects of these treatments are consistent with the standard pathophysiologic model of PD. However, the common effects in the cerebellum are not readily explained by the model. Consistent deactivation of the cerebellum is interesting in light of recent reports of synaptic pathways directly connecting the cerebellum and basal ganglia, and may warrant further consideration for incorporation into the model. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Moteabbed, M.; España, S.; Paganetti, H.
2011-02-01
The purpose of this work was to compare the clinical adaptation of prompt gamma (PG) imaging and positron emission tomography (PET) as independent tools for non-invasive proton beam range verification and treatment validation. The PG range correlation and its differences with PET have been modeled for the first time in a highly heterogeneous tissue environment, using different field sizes and configurations. Four patients with different tumor locations (head and neck, prostate, spine and abdomen) were chosen to compare the site-specific behaviors of the PG and PET images, using both passive scattered and pencil beam fields. Accurate reconstruction of dose, PG and PET distributions was achieved by using the planning computed tomography (CT) image in a validated GEANT4-based Monte Carlo code capable of modeling the treatment nozzle and patient anatomy in detail. The physical and biological washout phenomenon and decay half-lives for PET activity for the most abundant isotopes such as 11C, 15O, 13N, 30P and 38K were taken into account in the data analysis. The attenuation of the gamma signal after traversing the patient geometry and respective detection efficiencies were estimated for both methods to ensure proper comparison. The projected dose, PG and PET profiles along many lines in the beam direction were analyzed to investigate the correlation consistency across the beam width. For all subjects, the PG method showed on average approximately 10 times higher gamma production rates than the PET method before, and 60 to 80 times higher production after including the washout correction and acquisition time delay. This rate strongly depended on tissue density and elemental composition. For broad passive scattered fields, it was demonstrated that large differences exist between PG and PET signal falloff positions and the correlation with the dose distribution for different lines in the beam direction. These variations also depended on the treatment site and the particular subject. Thus, similar to PET, direct range verification with PG in passive scattering is not easily viable. However, upon development of an optimized 3D PG detector, indirect range verification by comparing measured and simulated PG distributions (currently being explored for the PET method) would be more beneficial because it can avoid the inherent biological challenges of the PET imaging. The improved correlation of PG and PET with dose when using pencil beams was evident. PG imaging was found to be potentially advantageous especially for small tumors in the presence of high tissue heterogeneities. Including the effects of detector acceptance and efficiency may hold PET superior in terms of the amplitude of the detected signal (depending on the future development of PG detection technology), but the ability to perform online measurements and avoid signal disintegration (due to washout) with PG are important factors that can outweigh the benefits of higher detection sensitivity.
Moteabbed, M; España, S; Paganetti, H
2011-02-21
The purpose of this work was to compare the clinical adaptation of prompt gamma (PG) imaging and positron emission tomography (PET) as independent tools for non-invasive proton beam range verification and treatment validation. The PG range correlation and its differences with PET have been modeled for the first time in a highly heterogeneous tissue environment, using different field sizes and configurations. Four patients with different tumor locations (head and neck, prostate, spine and abdomen) were chosen to compare the site-specific behaviors of the PG and PET images, using both passive scattered and pencil beam fields. Accurate reconstruction of dose, PG and PET distributions was achieved by using the planning computed tomography (CT) image in a validated GEANT4-based Monte Carlo code capable of modeling the treatment nozzle and patient anatomy in detail. The physical and biological washout phenomenon and decay half-lives for PET activity for the most abundant isotopes such as (11)C, (15)O, (13)N, (30)P and (38)K were taken into account in the data analysis. The attenuation of the gamma signal after traversing the patient geometry and respective detection efficiencies were estimated for both methods to ensure proper comparison. The projected dose, PG and PET profiles along many lines in the beam direction were analyzed to investigate the correlation consistency across the beam width. For all subjects, the PG method showed on average approximately 10 times higher gamma production rates than the PET method before, and 60 to 80 times higher production after including the washout correction and acquisition time delay. This rate strongly depended on tissue density and elemental composition. For broad passive scattered fields, it was demonstrated that large differences exist between PG and PET signal falloff positions and the correlation with the dose distribution for different lines in the beam direction. These variations also depended on the treatment site and the particular subject. Thus, similar to PET, direct range verification with PG in passive scattering is not easily viable. However, upon development of an optimized 3D PG detector, indirect range verification by comparing measured and simulated PG distributions (currently being explored for the PET method) would be more beneficial because it can avoid the inherent biological challenges of the PET imaging. The improved correlation of PG and PET with dose when using pencil beams was evident. PG imaging was found to be potentially advantageous especially for small tumors in the presence of high tissue heterogeneities. Including the effects of detector acceptance and efficiency may hold PET superior in terms of the amplitude of the detected signal (depending on the future development of PG detection technology), but the ability to perform online measurements and avoid signal disintegration (due to washout) with PG are important factors that can outweigh the benefits of higher detection sensitivity.
Determination of the δ15N and δ18O of nitrate in water; RSIL lab code 2900
Coplen, Tyler B.; Qi, Haiping; Revesz, Kinga; Casciotti, Karen; Hannon, Janet E.
2007-01-01
The purpose of the Reston Stable Isotope Laboratory (RSIL) lab code 2900 is to determine the δ15N and δ18O of nitrate (NO3-) in water. The δ15N and δ18O of the dissolved NO3- are analyzed by converting the NO3- to nitrous oxide (N2O), which serves as the analyte for mass spectrometry. A culture of denitrifying bacteria is used in the enzymatic conversion of the NO3- to N2O, which follows the pathway shown in equation 1: NO3- → NO2- → NO → 1/2 N2O (1) Because the bacteria Pseudomonas aureofaciens lack N2O reductive activity, the reaction stops at N2O, unlike the typical denitrification reaction that goes to N2. After several hours, the conversion is complete, and the N2O is extracted from the vial, separated from volatile organic vapor and water vapor by an automated -65 °C isopropanol-slush trap, a Nafion drier, a CO2 and water removal unit (Costech #021020 carbon dioxide absorbent with Mg(ClO4)2), and trapped in a small-volume trap immersed in liquid nitrogen with a modified Finnigan MAT (now Thermo Scientific) GasBench 2 introduction system. After the N2O is released, it is further purified by gas chromatography before introduction to the isotope-ratio mass spectrometer (IRMS). The IRMS is a Thermo Scientific Delta V Plus continuous flow IRMS (CF-IRMS). It has a universal triple collector, consisting of two wide cups with a narrow cup in the middle; it is capable of simultaneously measuring mass/charge (m/z) of the N2O molecule 44, 45, and 46. The ion beams from these m/z values are as follows: m/z = 44 = N2O = 14N14N16O; m/z = 45 = N2O = 14N15N16O or 14N14N17O; m/z = 46 = N2O = 14N14N18O. The 17O contributions to the m/z 44 and m/z 45 ion beams are accounted for before δ15N values are reported.
Self-consolidating concretes containing waste PET bottles as sand replacement
NASA Astrophysics Data System (ADS)
Khalid, Faisal Sheikh; Azmi, Nurul Bazilah; Mazenan, Puteri Natasya; Shahidan, Shahiron; Othman, Nor hazurina; Guntor, Nickholas Anting Anak
2018-02-01
This study evaluates the effect of self-consolidating concrete (SCC) containing waste polyethylene terephthalate (PET) granules on the fresh, mechanical and water absorption properties. Fine aggregates were replaced from 0% to 8% by PET granules. The fresh properties of SCC containing PET granules were determined using slump flow and V-funnel flow time tests. The compressive and splitting tensile strength were evaluated. The results indicated that utilization of waste PET granules in production of SCC could be an effective way for recycling purpose. The maximum amount of PET replacement should be limited to 5%. Exceeding 5% of PET content may result in an increase of V-funnel flow time to overpass the limiting value, decrease in strength. The production of high performance SCC containing 5% PET granules satisfies all the requirements for SCC with satisfactory outputs.
Park, Hae-Jeong; Park, Bumhee; Kim, Hae Yu; Oh, Maeng-Keun; Kim, Joong Il; Yoon, Misun; Lee, Jong Doo; Chang, Jin Woo
2015-05-01
As Parkinson's disease (PD) can be considered a network abnormality, the effects of deep brain stimulation (DBS) need to be investigated in the aspect of networks. This study aimed to examine how DBS of the bilateral subthalamic nucleus (STN) affects the motor networks of patients with idiopathic PD during motor performance and to show the feasibility of the network analysis using cross-sectional positron emission tomography (PET) images in DBS studies. We obtained [¹⁵O]H₂O PET images from ten patients with PD during a sequential finger-to-thumb opposition task and during the resting state, with DBS-On and DBS-Off at STN. To identify the alteration of motor networks in PD and their changes due to STN-DBS, we applied independent component analysis (ICA) to all the cross-sectional PET images. We analysed the strength of each component according to DBS effects, task effects and interaction effects. ICA blindly decomposed components of functionally associated distributed clusters, which were comparable to the results of univariate statistical parametric mapping. ICA further revealed that STN-DBS modifies usage-strengths of components corresponding to the basal ganglia-thalamo-cortical circuits in PD patients by increasing the hypoactive basal ganglia and by suppressing the hyperactive cortical motor areas, ventrolateral thalamus and cerebellum. Our results suggest that STN-DBS may affect not only the abnormal local activity, but also alter brain networks in patients with PD. This study also demonstrated the usefulness of ICA for cross-sectional PET data to reveal network modifications due to DBS, which was not observable using the subtraction method.
Oliveira, Bruno L.; Blasi, Francesco; Rietz, Tyson A.; Rotile, Nicholas J.; Day, Helen; Caravan, Peter
2016-01-01
We recently showed the high target specificity and favorable imaging properties of 64Cu and Al18F positron emission tomography (PET) probes for non-invasive imaging of thrombosis. Here, our aim was to evaluate new derivatives labeled with either with 68Ga, 111In, or 99mTc as thrombus imaging agents for PET and single-photon emission computed tomography (SPECT). In this study, the feasibility and potential of these probes for thrombus imaging was assessed in detail in two animal models of arterial thrombosis. The specificity of the probes was further evaluated using a triple-isotope approach with multimodal SPECT/PET/CT imaging. Methods Radiotracers were synthesized using a known fibrin-binding peptide conjugated to NODAGA, DOTA-MA, or a diethylenetriamine ligand (DETA-PA), followed by labeling with 68Ga (FBP14, 68Ga-NODAGA), 111In (FBP15, 111In-DOTA-MA) or 99mTc (FBP16, 99mTc(CO)3-DETA-PA), respectively. PET or SPECT imaging, biodistribution, pharmacokinetics and metabolic stability were evaluated in rat models of mural and occlusive carotid artery thrombosis. In vivo target specificity was evaluated by comparing the distribution of the SPECT and PET probes with preformed 125I-labeled thrombi and with a non-binding control probe using SPECT/PET/CT imaging. Results All three radiotracers showed similar affinity to soluble fibrin fragment DD(E) (Ki = 0.53–0.83 μM). After the kidneys, the highest uptake of 68Ga-FBP14 and 111In-FBP15 was in the thrombus (1.0 ± 0.2% ID/g) with low off-target accumulation. Both radiotracers underwent fast systemic elimination (t1/2 = 8-15 min) through the kidneys, which led to highly conspicuous thrombi on PET and SPECT images. 99mTc-FBP16 displayed low target uptake and distribution consistent with aggregation and/or degradation. Triple isotope imaging experiments showed that both 68Ga-FBP14 and 111In-FBP15, but not the nonbinding derivative 64Cu-D-Cys-FBP8, detected the location of the 125I-labeled thrombus, confirming high target specificity. Conclusion 68Ga-FBP14 and 111In-FBP15 have high fibrin affinity and thrombus specificity, and represent useful PET and SPECT probes for thrombus detection. PMID:26251420
Kebir, Sied; Khurshid, Zain; Gaertner, Florian C.; Essler, Markus; Hattingen, Elke; Fimmers, Rolf; Scheffler, Björn; Herrlinger, Ulrich; Bundschuh, Ralph A.; Glas, Martin
2017-01-01
Rationale Timely detection of pseudoprogression (PSP) is crucial for the management of patients with high-grade glioma (HGG) but remains difficult. Textural features of O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography (FET-PET) mirror tumor uptake heterogeneity; some of them may be associated with tumor progression. Methods Fourteen patients with HGG and suspected of PSP underwent FET-PET imaging. A set of 19 conventional and textural FET-PET features were evaluated and subjected to unsupervised consensus clustering. The final diagnosis of true progression vs. PSP was based on follow-up MRI using RANO criteria. Results Three robust clusters have been identified based on 10 predominantly textural FET-PET features. None of the patients with PSP fell into cluster 2, which was associated with high values for textural FET-PET markers of uptake heterogeneity. Three out of 4 patients with PSP were assigned to cluster 3 that was largely associated with low values of textural FET-PET features. By comparison, tumor-to-normal brain ratio (TNRmax) at the optimal cutoff 2.1 was less predictive of PSP (negative predictive value 57% for detecting true progression, p=0.07 vs. 75% with cluster 3, p=0.04). Principal Conclusions Clustering based on textural O-(2-[18F]fluoroethyl)-L-tyrosine PET features may provide valuable information in assessing the elusive phenomenon of pseudoprogression. PMID:28030820
Kroiss, Alexander; Putzer, Daniel; Frech, Andreas; Decristoforo, Clemens; Uprimny, Christian; Gasser, Rudolf Wolfgang; Shulkin, Barry Lynn; Url, Christoph; Widmann, Gerlig; Prommegger, Rupert; Sprinzl, Georg Mathias; Fraedrich, Gustav; Virgolini, Irene Johanna
2013-12-01
(18)F-Fluoro-L-dihydroxyphenylalanine ((18)F-DOPA) PET offers high sensitivity and specificity in the imaging of nonmetastatic extra-adrenal paragangliomas (PGL) but lower sensitivity in metastatic or multifocal disease. These tumours are of neuroendocrine origin and can be detected by (68)Ga-DOTA-Tyr(3)-octreotide ((68)Ga-DOTA-TOC) PET. Therefore, we compared (68)Ga-DOTA-TOC and (18)F-DOPA as radiolabels for PET/CT imaging for the diagnosis and staging of extra-adrenal PGL. Combined cross-sectional imaging was the reference standard. A total of 5 men and 15 women (age range 22 to 73 years) with anatomical and/or histologically proven extra-adrenal PGL were included in this study. Of these patients, 5 had metastatic or multifocal lesions and 15 had single sites of disease. Comparative evaluation included morphological imaging with CT and functional imaging with (68)Ga-DOTA-TOC PET and (18)F-DOPA PET. The imaging results were analysed on a per-patient and a per-lesion basis. The maximum standardized uptake value (SUVmax) of each functional imaging modality in concordant tumour lesions was measured. Compared with anatomical imaging, (68)Ga-DOTA-TOC PET and (18)F-DOPA PET each had a per-patient and per-lesion detection rate of 100% in nonmetastatic extra-adrenal PGL. However, in metastatic or multifocal disease, the per-lesion detection rate of (68)Ga-DOTA-TOC was 100% and that of (18)F-DOPA PET was 56.0%. Overall, (68)Ga-DOTA-TOC PET identified 45 lesions; anatomical imaging identified 43 lesions, and (18)F-DOPA PET identified 32 lesions. The overall per-lesion detection rate of (68)Ga-DOTA-TOC PET was 100% (McNemar, P < 0.5), and that of (18)F-DOPA PET was 71.1% (McNemar, P < 0.001). The SUVmax (mean ± SD) of all 32 concordant lesions was 67.9 ± 61.5 for (68)Ga-DOTA-TOC PET and 11.8 ± 7.9 for (18)F-DOPA PET (Mann-Whitney U test, P < 0.0001). (68)Ga-DOTA-TOC PET may be superior to (18)F-DOPA PET and diagnostic CT in providing valuable information for pretherapeutic staging of extra-adrenal PGL, particularly in surgically inoperable tumours and metastatic or multifocal disease.
Mechanisms controlling the impact of multi-year drought on mountain hydrology.
Bales, Roger C; Goulden, Michael L; Hunsaker, Carolyn T; Conklin, Martha H; Hartsough, Peter C; O'Geen, Anthony T; Hopmans, Jan W; Safeeq, Mohammad
2018-01-12
Mountain runoff ultimately reflects the difference between precipitation (P) and evapotranspiration (ET), as modulated by biogeophysical mechanisms that intensify or alleviate drought impacts. These modulating mechanisms are seldom measured and not fully understood. The impact of the warm 2012-15 California drought on the heavily instrumented Kings River basin provides an extraordinary opportunity to enumerate four mechanisms that controlled the impact of drought on mountain hydrology. Two mechanisms intensified the impact: (i) evaporative processes have first access to local precipitation, which decreased the fractional allocation of P to runoff in 2012-15 and reduced P-ET by 30% relative to previous years, and (ii) 2012-15 was 1 °C warmer than the previous decade, which increased ET relative to previous years and reduced P-ET by 5%. The other two mechanisms alleviated the impact: (iii) spatial heterogeneity and the continuing supply of runoff from higher elevations increased 2012-15 P-ET by 10% relative to that expected for a homogenous basin, and iv) drought-associated dieback and wildfire thinned the forest and decreased ET, which increased 2016 P-ET by 15%. These mechanisms are all important and may offset each other; analyses that neglect one or more will over or underestimate the impact of drought and warming on mountain runoff.
Errors in MR-based attenuation correction for brain imaging with PET/MR scanners
NASA Astrophysics Data System (ADS)
Rota Kops, Elena; Herzog, Hans
2013-02-01
AimAttenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methodsAn anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). ResultsError A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled nasal cavity yielded an overestimation in cerebellum up to 5%. ConclusionsThe present error analysis confirms that our template-based attenuation method provides reliable attenuation corrections of PET brain imaging measured in PET/MR scanners.
NASA Astrophysics Data System (ADS)
Biswas, A.; Lotha, S.; Gupta, R.; Avasthi, D. K.; Paul, S. N.
2002-04-01
Thin films (13 μm) of polyethelene terephthalate (PET) are irradiated by different swift metallic heavy ions (180 MeV Ag14+ and 200 MeV Au15+) with the projectile linear energy transfer (LET) (˜10-14 keV/nm), respectively. LET dependence on the molecular structural changes in PFT irradiated at different ion fluences has been studied by the Fourier transform infrared spectroscopy. The study has revealed that beyond a critical LET entirely different pathways of amorphization beginning with partial recrystallization at lower ion fluence impact occurs in PET, contrary to the earlier established results. At considerably higher LET (˜14 keV/nm), the most characteristic crystalline stretching and bending vibration bands such as at 850 cm-1 (CH2 rocking), 972 cm-1 (C=O stretching), 1341 and 1471 cm-1 (CH2 bending) in PET have shown a significant rise in the respective infrared absorbance intensities upon lower ion fluence (˜1011 ions/cm2) impact. The absence of previously reported unsaturations such as alkynes at both the LET beam used are also observed. Interestingly, the aromatic system also appears to be unstable and participating in the modification process, particularly at the higher LET (˜14 KeV/nm). Possible interpretations are discussed.
Mantoulan, Carine; Payoux, Pierre; Diene, Gwenaëlle; Glattard, Mélanie; Rogé, Bernadette; Molinas, Catherine; Sevely, Annick; Zilbovicius, Monica; Celsis, Pierre; Tauber, Maïthé
2011-01-01
The Prader-Willi syndrome (PWS), a rare multisystem genetic disease, leads to severe disabilities, such as morbid obesity, endocrine dysfunctions, psychiatric disorders, and social disturbances. We explored the whole brain of patients with PWS to detect abnormalities that might explain the behavioral and social disturbances, as well as the psychiatric disorders of these patients. Nine patients with PWS (six males, three females; mean age 16.4 years) underwent a positron emission tomography (PET) scan with H(2)(15)O as a tracer to measure regional cerebral blood flow (rCBF). The images were compared with those acquired from nine controls (six males, three females; mean age 21.2 years). A morphologic magnetic resonance imaging (MRI) was also performed in PWS patients, and their cognitive and behavioral skills were assessed with Wechsler Intelligence Scale for Children III and the Child Behavior Check List (CBCL). The MRI images showed no evident anatomic abnormalities, whereas PET scans revealed hypoperfused brain regions in PWS patients compared with controls, particularly in the anterior cingulum and superior temporal regions. We observed a significant relationship (P<0.05) between rCBF in the hypoperfused regions and CBCL scores. The functional consequences of these perfusion abnormalities in specific brain regions might explain the behavioral and social problems observed in these individuals.
Rodríguez-Garcia, O; González-Romero, V M; Fernández-Escartín, E
2011-09-01
This study was intended to evaluate the bactericidal effect of electrolyzed oxidizing water (EOW) and chlorinated water on populations of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes inoculated on avocados (Persea americana var. Hass). In the first experiment, inoculated avocados were treated with a water wash applied by spraying tap water containing 1 mg/liter free chlorine for 15 s (WW); WW treatment and then spraying sodium hypochlorite in water containing 75 mg/liter free chlorine for 15 s (Cl75); WW treatment and then spraying alkaline EOW for 30 s (AkEW) and then spraying acid EOW (AcEW) for 15 s; and spraying AkEW and then AcEW. In another experiment, the inoculated avocados were treated by spraying AkEW and then AcEW for 15, 30, 60, or 90 s. All three pathogen populations were lowered between 3.6 and 3.8 log cycles after WW treatment. The application of Cl75 did not produce any further reduction in counts, whereas AkEW and then AcEW treatment resulted in significantly lower bacterial counts for L. monocytogenes and E. coli O157:H7 but not for Salmonella. Treatments with AkEW and then AcEW produced a significant decrease in L. monocytogenes, Salmonella, and E. coli O157:H7 populations, with estimated log reductions of 3.9 to 5.2, 5.1 to 5.9, and 4.2 to 4.9 log CFU/cm², respectively. Spraying AcEW for more than 15 s did not produce any further decrease in counts of Salmonella or E. coli O157:H7, whereas L. monocytogenes counts were significantly lower after spraying AcEW for 60 s. Applying AkEW and then AcEW for 15 or 30 s seems to be an effective alternative to reduce bacterial pathogens on avocado surfaces.
NASA Astrophysics Data System (ADS)
Wang, Qingyi; Yang, Dechao; Qiu, Yu; Zhang, Xiaotong; Song, Wenbin; Hu, Lizhong
2018-02-01
Here, we report the two-step growth method of two-dimensional (2-D) ZnO nanosheets (NSs) and explore their formation mechanism. Additionally, we illustrate their application for high-performance piezoelectric nanogenerators (NGs) by using grown products from various reaction times. The result shows that NGs based on 2-D NSs demonstrated better output performance than those based on 1-D NWs, which surprisingly increased from ˜40 nA to ˜0.15 μA under the same compressive force of ˜1 kgf. It can also be observed that the output current is slightly elevated as the 2-D nanostructures become thinner. Our results offer a unique way to improve the output performance of NGs by means of controlling the synthesis period of ZnO nanostructures, which have important applications in flexible electronics and wearable devices.
Use of Video Goggles to Distract Patients During PET/CT Studies of School-Aged Children.
Gelfand, Michael J; Harris, Jennifer M; Rich, Amanda C; Kist, Chelsea S
2016-12-01
This study was designed to evaluate the effectiveness of video goggles in distracting children undergoing PET/CT and to determine whether the goggles create CT and PET artifacts. Video goggles with small amounts of internal radioopaque material were used. During whole-body PET/CT imaging, 30 nonsedated patients aged 4-13 y watched videos of their choice using the goggles. Fifteen of the PET/CT studies were performed on a scanner installed in 2006, and the other 15 were performed on a scanner installed in 2013. The fused scans were reviewed for evidence of head movement, and the individual PET and CT scans of the head were reviewed for the presence and severity of streak artifact. The CT exposure settings were recorded for each scan at the anatomic level at which the goggles were worn. Only one of the 30 scans had evidence of significant head motion. Two of the 30 had minor coregistration problems due to motion, and 27 of the 30 had very good to excellent coregistration. For the 2006 scanner, 2 of the 14 evaluable localization CT scans of the head demonstrated no streak artifact in brain tissue, 6 of the 14 had mild streak artifact in brain tissue, and 6 of the 14 had moderate streak artifact in brain tissue. Mild streak artifact in bone was noted in 2 of the 14 studies. For the 2013 scanner, 7 of 15 studies had mild streak artifact in brain tissue and 8 of 15 had no streak artifact in brain tissue, whereas none of the 15 had streak artifact in bone. There were no artifacts attributable to the goggles on the 18 F-FDG PET brain images of any of the 29 evaluable studies. The average CT exposure parameters at the level of the orbits were 36% lower on the 2013 scanner than on the 2006 scanner. Video goggles may be used successfully to distract children undergoing PET with localization CT. The goggles cause no significant degradation of the PET brain images or the CT skull images. The degree of artifact on brain tissue images varies from none to moderate and depends on the CT equipment used. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Household Transmission of Clostridium difficile to Family Members and Domestic Pets.
Loo, Vivian G; Brassard, Paul; Miller, Mark A
2016-11-01
OBJECTIVE To determine the risk of Clostridium difficile transmission from index cases with C. difficile infection (CDI) to their household contacts and domestic pets. DESIGN A prospective study from April 2011 to June 2013. SETTING Patients with CDI from Canadian tertiary care centers. PARTICIPANTS Patients with CDI, their household human contacts, and pets. METHODS Epidemiologic information and stool or rectal swabs were collected from participants at enrollment and monthly for up to 4 months. Pulsed-field gel electrophoresis (PFGE) was performed on C. difficile isolates. Probable transmission was defined as the conversion of a C. difficile culture-negative contact to C. difficile culture-positive contact with a PFGE pattern indistinguishable or closely related to the index case. Possible transmission was defined as a contact with a positive C. difficile culture at baseline with a strain indistinguishable or closely related to the index case. RESULTS A total of 51 patients with CDI participated in this study; 67 human contacts and 15 pet contacts were included. Overall, 9 human contacts (13.4%) were C. difficile culture positive; 1 contact (1.5%) developed CDI; and 8 contacts were asymptomatic. Of 67 human contacts, probable transmission occurred in 1 human contact (1.5%) and possible transmission occurred in 5 human contacts (7.5%). Of 15 pet contacts, probable transmission occurred in 3 (20%) and possible transmission occurred in 1 (6.7%). CONCLUSIONS There was a high proportion of C. difficile culture positivity at 13.4% among human contacts and asymptomatic carriage of domestic pets reached 26.7%. These results suggest that household transmission of C. difficile may be a source of community-associated cases. Infect Control Hosp Epidemiol 2016;1-7.
Zhang, Wei; Li, Yuzhong; Xu, Chunying; Li, Qiaozhen; Lin, Wei
2016-07-08
Nitrous oxide (N2O) is a potent greenhouse gas. In North China, vegetable fields are amended with high levels of N fertilizer and irrigation water, which causes massive N2O flux. The aim of this study was to determine the contribution of microbial processes to N2O production and characterize isotopic signature effects on N2O source partitioning. We conducted a microcosm study that combined naturally abundant isotopologues and gas inhibitor techniques to analyze N2O flux and its isotopomer signatures [δ(15)N(bulk), δ(18)O, and SP (intramolecular (15)N site preference)] that emitted from vegetable soil after the addition of NH4(+) fertilizers. The results show that ammonia oxidation is the predominant process under high water content (70% water-filled pore space), and nitrifier denitrification contribution increases with increasing N content. δ(15)N(bulk) and δ(18)O of N2O may not provide information about microbial processes due to great shifts in precursor signatures and atom exchange, especially for soil treated with NH4(+) fertilizer. SP and associated two end-member mixing model are useful to distinguish N2O source and contribution. Further work is needed to explore isotopomer signature stability to improve N2O microbial process identification.
NASA Astrophysics Data System (ADS)
Zhang, Wei; Li, Yuzhong; Xu, Chunying; Li, Qiaozhen; Lin, Wei
2016-07-01
Nitrous oxide (N2O) is a potent greenhouse gas. In North China, vegetable fields are amended with high levels of N fertilizer and irrigation water, which causes massive N2O flux. The aim of this study was to determine the contribution of microbial processes to N2O production and characterize isotopic signature effects on N2O source partitioning. We conducted a microcosm study that combined naturally abundant isotopologues and gas inhibitor techniques to analyze N2O flux and its isotopomer signatures [δ15Nbulk, δ18O, and SP (intramolecular 15N site preference)] that emitted from vegetable soil after the addition of NH4+ fertilizers. The results show that ammonia oxidation is the predominant process under high water content (70% water-filled pore space), and nitrifier denitrification contribution increases with increasing N content. δ15Nbulk and δ18O of N2O may not provide information about microbial processes due to great shifts in precursor signatures and atom exchange, especially for soil treated with NH4+ fertilizer. SP and associated two end-member mixing model are useful to distinguish N2O source and contribution. Further work is needed to explore isotopomer signature stability to improve N2O microbial process identification.
Huang, Shih-Ying; Savic, Dragana; Yang, Jaewon; Shrestha, Uttam; Seo, Youngho
2014-11-01
Simultaneous imaging systems combining positron emission tomography (PET) and magnetic resonance imaging (MRI) have been actively investigated. A PET/MR imaging system (GE Healthcare) comprised of a time-of-flight (TOF) PET system utilizing silicon photomultipliers (SiPMs) and 3-tesla (3T) MRI was recently installed at our institution. The small-ring (60 cm diameter) TOF PET subsystem of this PET/MRI system can generate images with higher spatial resolution compared with conventional PET systems. We have examined theoretically and experimentally the effect of uniform magnetic fields on the spatial resolution for high-energy positron emitters. Positron emitters including 18 F, 124 I, and 68 Ga were simulated in water using the Geant4 Monte Carlo toolkit in the presence of a uniform magnetic field (0, 3, and 7 Tesla). The positron annihilation position was tracked to determine the 3D spatial distribution of the 511-keV gammy ray emission. The full-width at tenth maximum (FWTM) of the positron point spread function (PSF) was determined. Experimentally, 18 F and 68 Ga line source phantoms in air and water were imaged with an investigational PET/MRI system and a PET/CT system to investigate the effect of magnetic field on the spatial resolution of PET. The full-width half maximum (FWHM) of the line spread function (LSF) from the line source was determined as the system spatial resolution. Simulations and experimental results show that the in-plane spatial resolution was slightly improved at field strength as low as 3 Tesla, especially when resolving signal from high-energy positron emitters in the air-tissue boundary.
Positron Emission Tomography/Computed Tomography in the Staging and Treatment of Anal Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sveistrup, Joen, E-mail: joensveistrup@hotmail.com; Loft, Annika; Berthelsen, Anne Kiil
2012-05-01
Purpose: This study was intended to determine the role of PET/CT in the staging of anal cancer as a supplement to three-dimensional transanal ultrasound (TAUS) and inguinal ultrasound (US). The impact of the PET/CT on the initial stage and treatment plan proposed by TAUS/US was assessed. Methods and Materials: Ninety-five (95) patients referred to our clinic between July 1, 2005, and December 31, 2009, were retrospectively reviewed. All patients had biopsy-proven primary squamous cell cancer of the anal canal. There were 65 females (68%) and 30 males (32%), and the median age was 58 years (range, 35-88 years). Six (6%)more » of the patients were HIV positive. All patients were staged with TAUS/US and PET/CT. Results: Twenty-eight (28) patients were diagnosed with suspicious perirectal node metastases. TAUS visualized 24 of these, whereas PET/CT detected 15. Suspicious inguinal nodes were visualized on either US or PET/CT in 41 patients. Seventeen (17) of these had confirmed malignant disease on biopsy, and 15 had confirmed benign disease. All 17 patients (100%) with malignant inguinal nodes were diagnosed by PET/CT, whereas US identified 16 (94%). Ten patients were diagnosed with suspicious inguinal nodes on PET/CT that had not been seen on US. One of these was malignant, three were benign, and six were not biopsied. PET/CT diagnosed eight metastatic sites, whereas TAUS/US diagnosed three. PET/CT discovered three of the five synchronous cancers seen in this study. PET/CT upstaged the disease in 14% of the cases and changed the treatment plan proposed by TAUS/US in 17%. Conclusion: PET/CT has great potential influence on the staging and treatment of anal cancer. TAUS is important in the staging of the primary tumor and N1-stage, whereas PET/CT seems necessary for the N2/3-stage, the M-stage and synchronous cancers.« less
Iverson, S A; Brazil, A M; Ferguson, J M; Nelson, K; Lautenbach, E; Rankin, S C; Morris, D O; Davis, M F
2015-03-23
Methicillin-resistant strains of Staphylococcus aureus (MRSA), Staphylococcus pseudintermedius (MRSP), and other pathogenic staphylococci can cause infections in companion animals and humans. Identification of colonized animals is fundamental to research and practice needs, but harmonized methods have not yet been established. To establish the optimal anatomic site for the recovery of methicillin-resistant coagulase positive staphylococci (CPS), survey data and swabs were collected from 196 pets (dogs, cats, reptiles, birds, fish and pocket pets) that lived in households with an MRSA-infected person. Using broth-enrichment culture and PCR for speciation, S. aureus was identified in 27 of 179 (15%) pets sampled at baseline and 19 of 125 (15%) pets sampled at a three-month follow-up home visit. S. pseudintermedius was isolated from 33 of 179 (18%) pets sampled at baseline and 21 of 125 (17%) of pets sampled at follow-up. The baseline MRSA and MRSP prevalence was 8% and 1% respectively from 145 mammalian pets. The follow-up MRSA and MRSP prevalence was 7% and <1% respectively from 95 mammalian pets. The mouth was the most sensitive single site sampled for isolation of S. aureus and S. pseudintermedius in mammals. In a subset of pets, from which all available isolates were identified, dual carriage of S. aureus and S. pseudintermedius was 22% at baseline and 11% at follow-up. These results identify the mouth as the most sensitive site to screen for pathogenic staphylococci and suggest that it should be included in sampling protocols. Copyright © 2015 Elsevier B.V. All rights reserved.
18F-choline PET/MRI in suspected recurrence of prostate carcinoma.
Riola-Parada, C; Carreras-Delgado, J L; Pérez-Dueñas, V; Garcerant-Tafur, M; García-Cañamaque, L
2018-05-21
To evaluate the usefulness of simultaneous 18 F-choline PET/MRI in the suspicion of prostate cancer recurrence and to relate 18 F-choline PET/MRI detection rate with analytical and pathological variables. 27 patients with prostate cancer who received local therapy as primary treatment underwent a 18 F-choline PET/MRI due to suspicion of recurrence (persistently rising serum PSA level). 18 F-choline PET/MRI findings were validated by anatomopathological analysis, other imaging tests or by biochemical response to oncological treatment. 18 F-choline PET/MRI detected disease in 15 of 27 patients (detection rate 55.56%). 4 (15%) presented exclusively local recurrence, 5 (18%) lymph node metastases and 7 (26%) bone metastases. Mean PSA (PSA med ) at study time was 2.94ng/mL (range 0.18-10ng/mL). PSA med in patients with positive PET/MRI was 3.70ng/mL (range 0.24-10ng/mL), higher than in patients with negative PET/MRI, PSA med 1.97ng/mL (range 0.18-4.38ng/mL), although without statistically significant differences. Gleason score at diagnosis in patients with a positive study was 7.33 (range 6-9) and in patients with a negative study was 7 (range 6-9), without statistically significant differences. 18 F-choline PET/MRI detection rate was considerable despite the relatively low PSA values in our sample. The influence of Gleason score and PSA level on 18 F-choline PET/MRI detection rate was not statistically significant. Copyright © 2018 Sociedad Española de Medicina Nuclear e Imagen Molecular. Publicado por Elsevier España, S.L.U. All rights reserved.
Chen, Yi-Ming; Lin, Che-Li; Wei, Li; Hsu, Yi-Ju; Chen, Kuan-Neng; Huang, Chi-Chang; Kao, Chin-Hsung
2016-01-01
Exercise and fitness training programs have attracted the public’s attention in recent years. Sports nutrition supplementation is an important issue in the global sports market. Purpose: In this study, we designed a power exercise training (PET) program with a mouse model based on a strength and conditional training protocol for humans. We tested the effect of supplementation with functional branched-chain amino acid (BCAA)-rich sake protein (SP) to determine whether the supplement had a synergistic effect during PET and enhanced athletic performance and resistance to fatigue. Methods: Male ICR mice were divided into three groups (n = 8 per group) for four-week treatment: sedentary controls with vehicle (SC), and PET and PET groups with SP supplementation (3.8 g/kg, PET + SP). Exercise performance was evaluated by forelimb grip strength and exhaustive swimming time as well as changes in body composition and anti-fatigue activity levels of serum lactate, ammonia, glucose, and creatine kinase (CK) after a 15-min swimming exercise. The biochemical parameters were measured at the end of the experiment. Results: four-week PET significantly increased grip strength and exhaustive swimming time and decreased epididymal fat pad (EFP) weight and area. Levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatinine, and uric acid (UA) were significantly increased. PET + SP supplementation significantly decreased serum lactate, ammonia and CK levels after the 15-min swimming exercise. The resting serum levels of AST, ALT, CREA and UA were all significantly decreased with PET + SP. Conclusion: The PET program could increase the exercise performance and modulate the body composition of mice. PET with SP conferred better anti-fatigue activity, improved biochemical profiles, and may be an effective ergogenic aid in strength training. PMID:26907336
Chen, Yi-Ming; Lin, Che-Li; Wei, Li; Hsu, Yi-Ju; Chen, Kuan-Neng; Huang, Chi-Chang; Kao, Chin-Hsung
2016-02-20
Exercise and fitness training programs have attracted the public's attention in recent years. Sports nutrition supplementation is an important issue in the global sports market. In this study, we designed a power exercise training (PET) program with a mouse model based on a strength and conditional training protocol for humans. We tested the effect of supplementation with functional branched-chain amino acid (BCAA)-rich sake protein (SP) to determine whether the supplement had a synergistic effect during PET and enhanced athletic performance and resistance to fatigue. Male ICR mice were divided into three groups (n = 8 per group) for four-week treatment: sedentary controls with vehicle (SC), and PET and PET groups with SP supplementation (3.8 g/kg, PET + SP). Exercise performance was evaluated by forelimb grip strength and exhaustive swimming time as well as changes in body composition and anti-fatigue activity levels of serum lactate, ammonia, glucose, and creatine kinase (CK) after a 15-min swimming exercise. The biochemical parameters were measured at the end of the experiment. four-week PET significantly increased grip strength and exhaustive swimming time and decreased epididymal fat pad (EFP) weight and area. Levels of aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatinine, and uric acid (UA) were significantly increased. PET + SP supplementation significantly decreased serum lactate, ammonia and CK levels after the 15-min swimming exercise. The resting serum levels of AST, ALT, CREA and UA were all significantly decreased with PET + SP. The PET program could increase the exercise performance and modulate the body composition of mice. PET with SP conferred better anti-fatigue activity, improved biochemical profiles, and may be an effective ergogenic aid in strength training.
de Godoy, M R C; Ochi, K; de Oliveira Mateus, L F; de Justino, A C C; Swanson, K S
2015-05-01
The objective of this study was to investigate whether increased dietary water content and feeding frequency increased voluntary physical activity of young, lean adult female cats. A replicated 4 × 4 Latin square design with a 2 × 2 factorial treatment arrangement (feeding frequency and water content) was used. The 4 treatments consisted of 1 meal daily dry pet food without added water (1D; 12% moisture as is), 1 meal daily dry pet food with added water (1W; 70% total water content), 4 meals daily dry pet food without added water (4D; 12% moisture as is), and 4 meals daily dry pet food with added water (4W; 70% total water content). Eight healthy adult, lean, intact, young, female domestic shorthair cats were used in this experiment. Voluntary physical activity was evaluated using Actical activity monitors placed on collars and worn around the cats' necks for the last 7 d of each experimental period of 14 d. Food anticipatory activity (FAA) was calculated based on 2 h prior to feeding periods and expressed as a percentage of total daily voluntary physical activity. Increased feeding frequency (4 vs. 1 meal daily) resulted in greater average daily activity (P = 0.0147), activity during the light period (P = 0.0023), and light:dark activity ratio (P = 0.0002). In contrast, physical activity during the dark period was not altered by feeding frequency (P > 0.05). Cats fed 4 meals daily had increased afternoon FAA (P= 0.0029) compared with cats fed once daily. Dietary water content did not affect any measure of voluntary physical activity. Increased feeding frequency is an effective strategy to increase the voluntary physical activity of cats. Thus, it may assist in the prevention and management of obesity.
Ruhl, J.F.
1995-01-01
Upgradient to downgradient mean or individual nitrogen isotope δ15N values in %o (delta units in parts per thousand) determined for sampled monitoring wells along the direction of ground-water flow through the five land-use settings were: (1) 5.1 %o and 4.0 %o for the feedlot and adjacent manured field; (2) 1.1 %o and 0.9 %o for the cultivated croplands irrigated with waste water; (3) 3.8 %o and 2.7 %o for the cultivated croplands irrigated with ground water; (4) 3.4 %o and 4.9 %o for the residential development; and (5) 1.7 %o and 3.0 %o for the three waste-water lagoons. Nitrate from fertilizer appeared to have been present in ground water at the waste-water lagoons, cultivated croplands irrigated with waste water, and cultivated croplands irrigated with ground water. Nitrate from soil organic matter rather than from animal waste appeared to have been present in ground water at the feedlot and adjacent manured field.
NASA Astrophysics Data System (ADS)
Hui-Mean, Foo; Yusop, Zulkifli; Yusof, Fadhilah
2018-03-01
Trend analysis for potential evapotranspiration (PET) and climatic water balance (CWB) is critical in identifying the wetness or dryness episodes with respect to the water surplus or deficit. The PET is computed based on the monthly average temperature for the entire Peninsular Malaysia using Thornthwaite parameterization. The trends and slope's magnitude for the PET and CWB were then investigated using Mann-Kendall, Spearman's rho tests and Thiel-Sen estimator. The 1-, 3-, 6- and 12-month standardised precipitation evapotranspiration index (SPEI) is applied to determine the drought episodes and the average recurrence interval are calculated based on the SPEI. The results indicate that most of the stations show an upward trend in annual and monthly PET while majority of the regions show an upward trend in annual CWB except for the Pahang state. The increasing trends detected in the CWB describe water is in excess especially during the northeast monsoons while the decreasing trends imply water insufficiency. The excess water is observed mostly in January especially in the west coast, east coast and southwest regions that suggest more water is available for crop requirement. The average recurrence interval for drought episodes is almost the same for the smaller severity with various time scale of SPEI and high probability of drought occurrence is observed for some regions. The findings are useful for policymakers and practitioners to improve water resources planning and management, in particular to minimise drought effects in the future. Future research shall address the influence of topography on drought behaviour using more meteorological stations and to include east Malaysia in the analysis.
Zwergal, Andreas; Günther, Lisa; Brendel, Matthias; Beck, Roswitha; Lindner, Simon; Xiong, Guoming; Eilles, Eva; Unterrainer, Marcus; Albert, Nathalie Lisa; Becker-Bense, Sandra; Brandt, Thomas; Ziegler, Sibylle; la Fougère, Christian; Dieterich, Marianne; Bartenstein, Peter
2017-01-01
The functional relevance of reactive gliosis for recovery from acute unilateral vestibulopathy is unknown. In the present study, glial activation was visualized in vivo by [ 18 F]GE180-PET in a rat model of unilateral labyrinthectomy (UL) and compared to behavioral vestibular compensation (VC) overtime. 14 Sprague-Dawley rats underwent a UL by transtympanic injection of bupivacaine/arsenilate, 14 rats a SHAM UL (injection of normal saline). Glial activation was depicted with [ 18 F]GE180-PET and ex vivo autoradiography at baseline and 7, 15, 30 days after UL/SHAM UL. Postural asymmetry and nystagmus were registered at 1, 2, 3, 7, 15, 30 days after UL/SHAM UL. Signs of vestibular imbalance were found only after UL, which significantly decreased until days 15 and 30. In parallel, [ 18 F]GE180-PET and ex vivo autoradiography depicted glial activation in the ipsilesional vestibular nerve and nucleus on days 7 and 15 after UL. Correlation analysis revealed a strong negative association of [ 18 F]GE180 uptake in the ipsilesional vestibular nucleus on day 7 with the rate of postural recovery ( R = -0.90, p < 0.001), suggesting that glial activation accelerates VC. In conclusion, glial activation takes place in the ipsilesional vestibular nerve and nucleus within the first 30 days after UL in the rat and can be visualized in vivo by [ 18 F]GE180-PET.
Zwergal, Andreas; Günther, Lisa; Brendel, Matthias; Beck, Roswitha; Lindner, Simon; Xiong, Guoming; Eilles, Eva; Unterrainer, Marcus; Albert, Nathalie Lisa; Becker-Bense, Sandra; Brandt, Thomas; Ziegler, Sibylle; la Fougère, Christian; Dieterich, Marianne; Bartenstein, Peter
2017-01-01
The functional relevance of reactive gliosis for recovery from acute unilateral vestibulopathy is unknown. In the present study, glial activation was visualized in vivo by [18F]GE180-PET in a rat model of unilateral labyrinthectomy (UL) and compared to behavioral vestibular compensation (VC) overtime. 14 Sprague-Dawley rats underwent a UL by transtympanic injection of bupivacaine/arsenilate, 14 rats a SHAM UL (injection of normal saline). Glial activation was depicted with [18F]GE180-PET and ex vivo autoradiography at baseline and 7, 15, 30 days after UL/SHAM UL. Postural asymmetry and nystagmus were registered at 1, 2, 3, 7, 15, 30 days after UL/SHAM UL. Signs of vestibular imbalance were found only after UL, which significantly decreased until days 15 and 30. In parallel, [18F]GE180-PET and ex vivo autoradiography depicted glial activation in the ipsilesional vestibular nerve and nucleus on days 7 and 15 after UL. Correlation analysis revealed a strong negative association of [18F]GE180 uptake in the ipsilesional vestibular nucleus on day 7 with the rate of postural recovery (R = −0.90, p < 0.001), suggesting that glial activation accelerates VC. In conclusion, glial activation takes place in the ipsilesional vestibular nerve and nucleus within the first 30 days after UL in the rat and can be visualized in vivo by [18F]GE180-PET. PMID:29312111
Nakajima, Reiko; Abe, Koichiro; Momose, Mitsuru; Fukushima, Kenji; Matsuo, Yuka; Kimura, Ken; Kondo, Chisato; Sakai, Shuji
2017-02-01
11 C-Methionine (MET) positron emission tomography (PET) imaging is a valuable technique for the evaluation of primary and recurrent brain tumors. Many studies have used MET-PET for data acquisition starting at 20 min after the tracer injection, while others have used scan initiation times at 5-15 min postinjection. No previous studies have identified the best acquisition timing during MET-PET imaging for suspected recurrent brain tumors. Here we sought to determine the optimal scan initiating timing after MET administration for the detection of recurrent brain tumors. Twenty-three consecutive patients with suspected recurrent brain tumors underwent MET-PET examinations. Brain PET images were reconstructed from the four serial data sets (10-15, 15-20, 20-25, and 25-30 min postinjection) that were obtained using the list-mode acquisition technique. We determined the maximal standardized uptake values (SUVmax) of the target lesions and the target-to-normal-tissue ratios (TNRs), calculated as the SUVmax to the SUVmean of a region of interest placed on the normal contralateral frontal cortex. Target lesions without significant MET uptake were excluded. Thirty-one lesions from 23 patients were enrolled. There were no significant differences in MET SUVmax or TNR values among the PET images that were reconstructed with the data extracted from the four phases postinjection. The MET uptake in the suspected recurrent brain tumors was comparable among all data extraction time phases from 10 to 30 min postinjection. The scan initiation time of MET-PET at 10 min after the injection is allowable for the detection of recurrent brain tumors. The registration identification number of the original study is 1002.
NASA Astrophysics Data System (ADS)
Kim, Duk Jae; Park, Jeongwon; Geon Han, Jeon
2016-08-01
We show results of the patterning of graphene layers on poly(ethylene terephthalate) (PET) films through remote atmospheric-pressure dielectric barrier discharge plasma. The size of plasma discharge electrodes was adjusted for large-area and role-to-role-type substrates. Optical emission spectroscopy (OES) was used to analyze the characteristics of charge species in atmospheric-pressure plasma. The OES emission intensity of the O2* peaks (248.8 and 259.3 nm) shows the highest value at the ratio of \\text{N}2:\\text{clean dry air (CDA)} = 100:1 due to the highest plasma discharge. The PET surface roughness and hydrophilic behavior were controlled with CDA flow rate during the process. Although the atmospheric-pressure plasma treatment of the PET film led to an increase in the FT-IR intensity of C-O bonding at 1240 cm-1, the peak intensity at 1710 cm-1 (C=O bonding) decreased. The patterning of graphene layers was confirmed by scanning electron microscopy and Raman spectroscopy.
Indium oxide-based transparent conductive films deposited by reactive sputtering using alloy targets
NASA Astrophysics Data System (ADS)
Miyazaki, Yusuke; Maruyama, Eri; Jia, Junjun; Machinaga, Hironobu; Shigesato, Yuzo
2017-04-01
High-quality transparent conductive oxide (TCO) films, Sn-doped In2O3 (ITO) and In2O3-ZnO (IZO), were successfully deposited on either synthetic silica or polyethylene terephthalate (PET) substrates in the “transition region” by reactive dc magnetron sputtering using In-Zn and In-Sn alloy targets, respectively, with a specially designed plasma emission feedback system. The composition, crystallinity, surface morphology, and electrical and optical properties of the films were analyzed. All of the IZO films were amorphous, whereas the ITO films were polycrystalline over a wide range of deposition conditions. The minimum resistivities of the IZO and ITO films deposited on the heated PET substrates at 150 °C were 3.3 × 10-4 and 5.4 × 10-4 Ω·cm, respectively. By applying rf bias to unheated PET substrates, ITO films with a resistivity of 4.4 × 10-4 Ω·cm were deposited at a dc self-bias voltage of -60 V.
NASA Astrophysics Data System (ADS)
Jinuntuya, M.; Ostrom, N. E.; Ostrom, P.; Sutka, R.
2005-12-01
Our prior research has demonstrated that the intramolecular distribution of 15N within the N2O molecule can be used to distinguish N2O derived from nitrification and denitrification. For this approach to be successful, however, the affect of fractionation during consumption of N2O by denitrification must be understood. Stable isotope and isotopomer analysis of soil mesocosm experiments were used to investigate fractionation of N2O during consumption at four different levels of water filled pores space (WFPS) 60, 80, 100 and 110% Uncultivated soil from the Long Term Ecological Research Site at Kellogg Biological Station was used to establish that the fractionation factors for δ15N, δ18O-N2O, δ15Nα and δ15Nβ ranged from -4.2 to -7.8 ‰, -12.5 to -19.1 ‰,-5.3 to -9.7‰ and -2.0 to -6.0 ‰, respectively. Lower fractionation factors were observed at higher WFPS demonstrating the importance of diffusion in limiting the expression of fractionation. The small degree of fractionation for δ15Nα and δ15Nβ indicates that consumption must be marked (e.g. >50%) before a significant isotope effect is observed. Our characterization of fractionation factors as a function of WFPS provides a basis to apportion the origins of N2O even when consumption is evident.
Viruses Inhibit CO2 Fixation in the Most Abundant Phototrophs on Earth.
Puxty, Richard J; Millard, Andrew D; Evans, David J; Scanlan, David J
2016-06-20
Marine picocyanobacteria of the genera Prochlorococcus and Synechococcus are the most numerous photosynthetic organisms on our planet [1, 2]. With a global population size of 3.6 × 10(27) [3], they are responsible for approximately 10% of global primary production [3, 4]. Viruses that infect Prochlorococcus and Synechococcus (cyanophages) can be readily isolated from ocean waters [5-7] and frequently outnumber their cyanobacterial hosts [8]. Ultimately, cyanophage-induced lysis of infected cells results in the release of fixed carbon into the dissolved organic matter pool [9]. What is less well known is the functioning of photosynthesis during the relatively long latent periods of many cyanophages [10, 11]. Remarkably, the genomes of many cyanophage isolates contain genes involved in photosynthetic electron transport (PET) [12-18] as well as central carbon metabolism [14, 15, 19, 20], suggesting that cyanophages may play an active role in photosynthesis. However, cyanophage-encoded gene products are hypothesized to maintain or even supplement PET for energy generation while sacrificing wasteful CO2 fixation during infection [17, 18, 20]. Yet this paradigm has not been rigorously tested. Here, we measured the ability of viral-infected Synechococcus cells to fix CO2 as well as maintain PET. We compared two cyanophage isolates that share different complements of PET and central carbon metabolism genes. We demonstrate cyanophage-dependent inhibition of CO2 fixation early in the infection cycle. In contrast, PET is maintained throughout infection. Our data suggest a generalized strategy among marine cyanophages to redirect photosynthesis to support phage development, which has important implications for estimates of global primary production. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Berding, Georg; Wilke, Florian; Rode, Thilo; Haense, Cathleen; Joseph, Gert; Meyer, Geerd J; Mamach, Martin; Lenarz, Minoo; Geworski, Lilli; Bengel, Frank M; Lenarz, Thomas; Lim, Hubert H
2015-01-01
Considerable progress has been made in the treatment of hearing loss with auditory implants. However, there are still many implanted patients that experience hearing deficiencies, such as limited speech understanding or vanishing perception with continuous stimulation (i.e., abnormal loudness adaptation). The present study aims to identify specific patterns of cerebral cortex activity involved with such deficiencies. We performed O-15-water positron emission tomography (PET) in patients implanted with electrodes within the cochlea, brainstem, or midbrain to investigate the pattern of cortical activation in response to speech or continuous multi-tone stimuli directly inputted into the implant processor that then delivered electrical patterns through those electrodes. Statistical parametric mapping was performed on a single subject basis. Better speech understanding was correlated with a larger extent of bilateral auditory cortex activation. In contrast to speech, the continuous multi-tone stimulus elicited mainly unilateral auditory cortical activity in which greater loudness adaptation corresponded to weaker activation and even deactivation. Interestingly, greater loudness adaptation was correlated with stronger activity within the ventral prefrontal cortex, which could be up-regulated to suppress the irrelevant or aberrant signals into the auditory cortex. The ability to detect these specific cortical patterns and differences across patients and stimuli demonstrates the potential for using PET to diagnose auditory function or dysfunction in implant patients, which in turn could guide the development of appropriate stimulation strategies for improving hearing rehabilitation. Beyond hearing restoration, our study also reveals a potential role of the frontal cortex in suppressing irrelevant or aberrant activity within the auditory cortex, and thus may be relevant for understanding and treating tinnitus.
Berding, Georg; Wilke, Florian; Rode, Thilo; Haense, Cathleen; Joseph, Gert; Meyer, Geerd J.; Mamach, Martin; Lenarz, Minoo; Geworski, Lilli; Bengel, Frank M.; Lenarz, Thomas; Lim, Hubert H.
2015-01-01
Considerable progress has been made in the treatment of hearing loss with auditory implants. However, there are still many implanted patients that experience hearing deficiencies, such as limited speech understanding or vanishing perception with continuous stimulation (i.e., abnormal loudness adaptation). The present study aims to identify specific patterns of cerebral cortex activity involved with such deficiencies. We performed O-15-water positron emission tomography (PET) in patients implanted with electrodes within the cochlea, brainstem, or midbrain to investigate the pattern of cortical activation in response to speech or continuous multi-tone stimuli directly inputted into the implant processor that then delivered electrical patterns through those electrodes. Statistical parametric mapping was performed on a single subject basis. Better speech understanding was correlated with a larger extent of bilateral auditory cortex activation. In contrast to speech, the continuous multi-tone stimulus elicited mainly unilateral auditory cortical activity in which greater loudness adaptation corresponded to weaker activation and even deactivation. Interestingly, greater loudness adaptation was correlated with stronger activity within the ventral prefrontal cortex, which could be up-regulated to suppress the irrelevant or aberrant signals into the auditory cortex. The ability to detect these specific cortical patterns and differences across patients and stimuli demonstrates the potential for using PET to diagnose auditory function or dysfunction in implant patients, which in turn could guide the development of appropriate stimulation strategies for improving hearing rehabilitation. Beyond hearing restoration, our study also reveals a potential role of the frontal cortex in suppressing irrelevant or aberrant activity within the auditory cortex, and thus may be relevant for understanding and treating tinnitus. PMID:26046763
Future water availability in North African dams simulated by high-resolution regional climate models
NASA Astrophysics Data System (ADS)
Tramblay, Yves; Jarlan, Lionel; Hanich, Lahoucine; Somot, Samuel
2016-04-01
In North Africa, the countries of Morocco, Algeria and Tunisia are already experiencing water scarcity and a strong interannual variability of precipitation. To better manage their existing water resources, several dams and reservoirs have been built on most large river catchments. The objective of this study is to provide quantitative scenarios of future changes in water availability for the 47 major dams and reservoirs catchments located in North Africa. An ensemble of regional climate models (RCM) with a spatial resolution of 12km, driven by different general circulation models (GCM), from the EuroCORDEX experiment have been considered to analyze the projected changes on temperature, precipitation and potential evapotranspiration (PET) for two scenarios (RCP4.5 and RCP8.5) and two time horizons (2040-2065 and 2065-2090). PET is estimated from RCM outputs either with the FAO-Penman-Monteith (PM) equation, requiring air temperature, relative humidity, net radiation and wind, or with the Hargreave Samani (HS) equation, requiring only air temperature. The water balance is analyzed by comparing the climatic demand and supply of water, considering that for most of these catchments groundwater storage is negligible over long time periods. Results indicated a future temperature increase for all catchments between +1.8° and +4.2°, depending on the emission scenario and the time period considered. Precipitation is projected to decrease between -14% to -27%, mainly in winter and spring, with a strong East to West gradient. PET computed from PM or HS formulas provided very similar estimates and projections, ranging between +7% to +18%. Changes in PET are mostly driven by rising temperatures and are greatest during dry summer months than for the wet winter season. Therefore the increased PET has a lower impact than declining precipitation on future water availability, which is expected to decrease by -19% to -33% on average.
Characterization of surface modified polyester fabric.
Joseph, Roy; Shelma, R; Rajeev, A; Muraleedharan, C V
2009-12-01
Woven polyethylene terephthalate (PET) fabric has been used in the construction of vascular grafts and sewing ring of prosthetic heart valves. In an effort to improve haemocompatibility and tissue response to PET fabric, a fluoropolymer, polyvinylidine fluoride (PVDF), was coated on PET fabric by dip coating technique. The coating was found to be uniform and no significant changes occurred on physical properties such as water permeability and burst strength. Cell culture cytotoxicity studies showed that coated PET was non-cytotoxic to L929 fibroblast cell lines. In vitro studies revealed that coating improved haemocompatibility of PET fabric material. Coating reduced platelet consumption of PET fabric by 50%. Upon surface modification leukocyte consumption of PET was reduced by 24%. About 60% reduction in partial thromboplastin time (PTT) observed when PET was coated with PVDF. Results of endothelial cell proliferation studies showed that surface coating did not have any substantial impact on cell proliferation. Overall results indicate that coating has potential to improve haemocompatibility of PET fabric without affecting its mechanical performance.
Naswa, Niraj; Sharma, Punit; Gupta, Santosh Kumar; Karunanithi, Sellam; Reddy, Rama Mohan; Patnecha, Manish; Lata, Sneh; Kumar, Rakesh; Malhotra, Arun; Bal, Chandrasekhar
2014-01-01
This study aimed to compare the diagnostic performance of Ga-DOTANOC PET/CT with F-FDG PET/CT in the patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs). Data of 51 patients with definite histological diagnosis of GEP-NET who underwent both Ga-DOTA-NOC PET-CT and F-FDG PET-CT within a span of 15 days were selected for this retrospective analysis. Sensitivity, specificity, and predictive values were calculated for Ga-DOTA-NOC PET-CT and F-FDG PET-CT, and results were compared both on patientwise and regionwise analysis. Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT on patientwise analysis (P < 0.0001). On regionwise analysis, Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT only for lymph node metastases (P < 0.003). Although Ga-DOTA-NOC PET-CT detected more liver and skeletal lesions compared with F-FDG PET-CT, the difference was not statistically significant. In addition, the results of combined imaging helped in selecting candidates who would undergo the appropriate mode of treatment, whether octreotide therapy or conventional chemotherapy Ga-DOTA-NOC PET-CT seems to be superior to F-FDG PET-CT for imaging GEP-NETs. However, their role seems to be complementary because combination of Ga-DOTA-NOC PET-CT and F-FDG PET-CT in such patients helps demonstrate the total disease burden and segregate them to proper therapeutic groups.
Beuthien-Baumann, B; Strumpf, A; Zessin, J; Bredow, J; Kotzerke, J
2007-10-01
In patients with medullary thyroid carcinoma (MTC), rising levels of the tumour markers calcitonin and CEA after primary surgery indicate tumour recurrence or metastases. The only chance of cure is the resection of localised tumour tissue. For positron emission tomography (PET) with (18)F-fluorodeoxyglucose ((18)F-FDG) and (18)F-dihydroxyphenylalanine ((18)F-DOPA), sensitivities of 78% and 63% have been reported, but in a considerable percentage of MTC patients the source of tumour marker elevation is not detected. The aim of this retrospective data evaluation was to compare the value of PET with (18)F-FDG, (18)F-DOPA and the amino acid tracer 3-O-methyl-6-[(18)F]fluoro-DOPA ((18)F-OMFD) in the detection of MTC recurrence. Fifteen patients with elevated calcitonin were investigated with PET as part of their individual clinical work-up. All patients underwent (18)F-FDG PET and (18)F-DOPA PET, and ten patients underwent (18)F-OMFD PET. With (18)F-FDG, seven patients showed foci in the neck, mediastinum, upper abdomen or bone. In seven patients, (18)F-DOPA revealed suspicious foci; five of these seven patients showed partially corresponding uptake of (18)F-FDG in the neck and mediastinum. Two of these patients underwent surgery and metastases were verified. With (18)F-OMFD, a small focus in the liver was suspected in one patient without a correlate on (18)F-FDG PET, (18)F-DOPA PET or conventional imaging. (18)F-FDG and (18)F-DOPA showed foci that were highly suspicious for local recurrence or metastasis of MTC, although histological verification in these patients with numerous previous surgical interventions was performed in only two patients. The amino acid tracer (18)F-OMFD had no diagnostic impact in these patients.
Recyclability assessment of nano-reinforced plastic packaging.
Sánchez, C; Hortal, M; Aliaga, C; Devis, A; Cloquell-Ballester, V A
2014-12-01
Packaging is expected to become the leading application for nano-composites by 2020 due to the great advantages on mechanical and active properties achieved with these substances. As novel materials, and although there are some current applications in the market, there is still unknown areas under development. One key issue to be addressed is to know more about the implications of the nano-composite packaging materials once they become waste. The present study evaluates the extrusion process of four nanomaterials (Layered silicate modified nanoclay (Nanoclay1), Calcium Carbonate (CaCO3), Silver (Ag) and Zinc Oxide (ZnO) as part of different virgin polymer matrices of polyethylene (PE), Polypropylene (PP) and Polyethyleneterephtalate (PET). Thus, the following film plastic materials: (PE-Nanoclay1, PE-CaCO3, PP-Ag, PET-ZnO, PET-Ag, PET-Nanoclay1) have been processed considering different recycling scenarios. Results on recyclability show that for PE and PP, in general terms and except for some minor variations in yellowness index, tensile modulus, tensile strength and tear strength (PE with Nanoclay1, PP with Ag), the introduction of nanomaterial in the recycling streams for plastic films does not affect the final recycled plastic material in terms of mechanical properties and material quality compared to conventional recycled plastic. Regarding PET, results show that the increasing addition of nanomaterial into the recycled PET matrix (especially PET-Ag) could influence important properties of the recycled material, due to a slight degradation of the polymer, such as increasing pinholes, degradation fumes and elongation at break. Moreover, it should be noted that colour deviations were visible in most of the samples (PE, PP and PET) in levels higher than 0.3 units (limit perceivable by the human eye). The acceptance of these changes in the properties of recycled PE, PP and PET will depend on the specific applications considered (e.g. packaging applications are more strict in material quality that urban furniture or construction products). Copyright © 2014 Elsevier Ltd. All rights reserved.
Temoçin, Zülfikar
2013-01-01
This study focuses on Candida rugosa lipase (CRL) immobilization by covalent attachment on poly(ethylene terephthalate)-grafted glycidyl methacrylate (PET-g-GMA) fiber. The immobilization yielded a protein loading of 2.38 mg g(-1) of PET-g-GMA fiber. The performances of the immobilized and free CRLs were evaluated with regard to hydrolysis of olive oil and esterification of oleic acid. The optimum activity pH of the CRL was changed by immobilization to neutral range. The maximum activity of the free and immobilized CRLs occurred at 40 and 45 °C respectively. The immobilized lipase retained 65% of its original activity at 50 °C for 2 h. It was found that the immobilized lipase stored at 4 °C retained 90% of its original activity after 35 days, whereas the free lipase stored at 4 °C retained 69% of its original activity after the same period. In the esterification experiments, the immobilized CRL could maintain a high activity at a water content range from 1.5 to 6% (v/v), while the activity of free CRL showed a clear dependence on water content and decreased rapidly at above 3% (v/v) water content. In addition, after five reuses, the esterification percent yield of the immobilized CRL slightly decreased from 29 to 27%.
Son, Dong-Ick; Park, Dong-Hee; Choi, Won Kook; Cho, Sung-Hwan; Kim, Won-Tae; Kim, Tae Whan
2009-05-13
The bistable effects of ZnO nanoparticles embedded in an insulating poly(methyl methacrylate) (PMMA) polymer single layer by using flexible polyethylene terephthalate (PET) substrates were investigated. Transmission electron microscopy (TEM) images revealed that ZnO nanoparticles were formed inside the PMMA polymer layer. Current-voltage (I-V) measurement on the Al/ZnO nanoparticles embedded in an insulating PMMA polymer layer/ITO/PET structures at 300 K showed a nonvolatile electrical bistability behavior with a flat-band voltage shift due to the existence of the ZnO nanoparticles, indicative of trapping, storing, and emission of charges in the electronic states of the ZnO nanoparticles. The carrier transport mechanism of the bistable behavior for the fabricated organic bistable device (OBD) structures is described on the basis of the I-V results by analyzing the effect of space charge.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhl, D.E.
1988-02-01
A brief progress report is presented describing the preparation and animal testing of /sup 11/C scopolamine and /sup 18/F fluoride. Additional studies entitled ''Automated Arterial Blood Sampling System for PET,'' Rapid Data Analysis Schemes for Functional Imaging in PET,'' and ''Tracer Kinetic Modeling in PET Measures of Cholinergic Receptors'' are described
Burger, C; Goerres, G; Schoenes, S; Buck, A; Lonn, A H R; Von Schulthess, G K
2002-07-01
The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation coefficients at the PET energy of 511 keV. As attenuation depends on photon energy and the absorbing material, an accurate theoretical relation cannot be devised. The transformation implemented in the Discovery LS PET/CT scanner (GE Medical Systems, Milwaukee, Wis.) uses a bilinear function based on the attenuation of water and cortical bone at the CT and PET energies. The purpose of this study was to compare this transformation with experimental CT values and corresponding PET attenuation coefficients. In 14 patients, quantitative PET attenuation maps were calculated from germanium-68 transmission scans, and resolution-matched CT images were generated. A total of 114 volumes of interest were defined and the average PET attenuation coefficients and CT values measured. From the CT values the predicted PET attenuation coefficients were calculated using the bilinear transformation. When the transformation was based on the narrow-beam attenuation coefficient of water at 511 keV (0.096 cm(-1)), the predicted attenuation coefficients were higher in soft tissue than the measured values. This bias was reduced by replacing 0.096 cm(-1) in the transformation by the linear attenuation coefficient of 0.093 cm(-1) obtained from germanium-68 transmission scans. An analysis of the corrected emission activities shows that the resulting transformation is essentially equivalent to the transmission-based attenuation correction for human tissue. For non-human material, however, it may assign inaccurate attenuation coefficients which will also affect the correction in neighbouring tissue.
Wehner, J; Weissler, B; Dueppenbecker, P M; Gebhardt, P; Goldschmidt, B; Schug, D; Kiessling, F; Schulz, V
2015-03-21
PET (positron emission tomography) with its high sensitivity in combination with MRI (magnetic resonance imaging) providing anatomic information with good soft-tissue contrast is considered to be a promising hybrid imaging modality. However, the integration of a PET detector into an MRI system is a challenging task since the MRI system is a sensitive device for external disturbances and provides a harsh environment for electronic devices. Consequently, the PET detector has to be transparent for the MRI system and insensitive to electromagnetic disturbances. Due to the variety of MRI protocols imposing a wide range of requirements regarding the MR-compatibility, an extensive study is mandatory to reliably assess worst-case interference phenomena between the PET detector and the MRI scanner. We have built the first preclinical PET insert, designed for a clinical 3 T MRI, using digital silicon photomultipliers (digital SiPM, type DPC 3200-22, Philips Digital Photon Counting). Since no thorough interference investigation with this new digital sensor has been reported so far, we present in this work such a comprehensive MR-compatibility study. Acceptable distortion of the B0 field homogeneity (volume RMS = 0.08 ppm, peak-to-peak value = 0.71 ppm) has been found for the PET detector installed. The signal-to-noise ratio degradation stays between 2-15% for activities up to 21 MBq. Ghosting artifacts were only found for demanding EPI (echo planar imaging) sequences with read-out gradients in Z direction caused by additional eddy currents originated from the PET detector. On the PET side, interference mainly between the gradient system and the PET detector occurred: extreme gradient tests were executed using synthetic sequences with triangular pulse shape and maximum slew rate. Under this condition, a relative degradation of the energy (⩽10%) and timing (⩽15%) resolution was noticed. However, barely measurable performance deterioration occurred when morphological MRI protocols are conducted certifying that the overall PET performance parameters remain unharmed.
Pathways for nitrate release from an alpine watershed: Determination using δ15N and δ18O
Campbell, Donald H.; Kendall, Carol; Chang, Cecily C.Y.; Silva, Steven R.; Tonnessen, Kathy A.
2002-01-01
Snowpack, snowmelt, precipitation, surface water, and groundwater samples from the Loch Vale watershed in Colorado were analyzed for δ15N and δ18O of nitrate to determine the processes controlling the release of atmospherically deposited nitrogen from alpine and subalpine ecosystems. Although overlap was found between the δ15N(NO3) values for all water types (−4 to +6‰), the δ18O(NO3) values for surface water and groundwater (+10 to +30‰) were usually distinct from snowpack, snowmelt, and rainfall values (+40 to +70‰). During snowmelt, δ18O(NO3) indicated that about half of the nitrate in stream water was the product of microbial nitrification; at other times that amount was greater than half. Springs emerging from talus deposits had high nitrate concentrations and a seasonal pattern in δ18O(NO3) that was similar to the pattern in the streams, indicating that shallow groundwater in talus deposits is a likely source of stream water nitrate. Only a few samples of surface water and groundwater collected during early snowmelt and large summer rain events had isotopic compositions that indicated most of the nitrate came directly from atmospheric deposition with no biological assimilation and release. This study demonstrates the value of the nitrate double‐isotope technique for determining nitrogen‐cycling processes and sources of nitrate in small, undisturbed watersheds that are enriched with inorganic nitrogen.
Anderson, Anita L.; Campbell, David L.; Beanland, Shay
2001-01-01
Individual mine waste samples were collected and combined to form one composite sample at each of eight mine dump sites in Colorado and New Mexico. The samples were air-dried and sieved to determine the geochemical composition of their <2mm size fraction. Splits of the samples were then rehydrated and their electrical properties were measured in the US Geological Survey Petrophysical Laboratory, Denver, Colorado (PetLab). The PetLab measurements were done twice: in 1999, using convenient amounts of rehydration water ranging from 5% to 8%; and in 2000, using carefully controlled rehydrations to 5% and 10% water. This report gives geochemical analyses of the <2mm size fraction of the composite samples (Appendix A), PetLab graphs of the 1999 measurements (Appendix B), Petlab graphs of the 2000 measurements (Appendix C), and Cole-Cole models of the PetLab data from the 2000 measurements (Appendix D).
Dye-sensitized solar cells using laser processing techniques
NASA Astrophysics Data System (ADS)
Kim, Heungsoo; Pique, Alberto; Kushto, Gary P.; Auyeung, Raymond C. Y.; Lee, S. H.; Arnold, Craig B.; Kafafi, Zakia H.
2004-07-01
Laser processing techniques, such as laser direct-write (LDW) and laser sintering, have been used to deposit mesoporous nanocrystalline TiO2 (nc-TiO2) films for use in dye-sensitized solar cells. LDW enables the fabrication of conformal structures containing metals, ceramics, polymers and composites on rigid and flexible substrates without the use of masks or additional patterning techniques. The transferred material maintains a porous, high surface area structure that is ideally suited for dye-sensitized solar cells. In this experiment, a pulsed UV laser (355nm) is used to forward transfer a paste of commercial TiO2 nanopowder (P25) onto transparent conducting electrodes on flexible polyethyleneterephthalate (PET) and rigid glass substrates. For the cells based on flexible PET substrates, the transferred TiO2 layers were sintered using an in-situ laser to improve electron paths without damaging PET substrates. In this paper, we demonstrate the use of laser processing techniques to produce nc-TiO2 films (~10 μm thickness) on glass for use in dye-sensitized solar cells (Voc = 690 mV, Jsc = 8.7 mA/cm2, ff = 0.67, η = 4.0 % at 100 mW/cm2). This work was supported by the Office of Naval Research.
Oliveira, Bruno L; Blasi, Francesco; Rietz, Tyson A; Rotile, Nicholas J; Day, Helen; Caravan, Peter
2015-10-01
We recently showed the high target specificity and favorable imaging properties of 64Cu and Al18F PET probes for noninvasive imaging of thrombosis. Here, our aim was to evaluate new derivatives labeled with either with 68Ga, 111In, or 99mTc as thrombus imaging agents for PET and SPECT. In this study, the feasibility and potential of these probes for thrombus imaging was assessed in detail in 2 animal models of arterial thrombosis. The specificity of the probes was further evaluated using a triple-isotope approach with multimodal SPECT/PET/CT imaging. Radiotracers were synthesized using a known fibrin-binding peptide conjugated to 1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid (NODAGA), 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid monoamide (DOTA-MA), or a diethylenetriamine ligand (DETA-propanoic acid [PA]), followed by labeling with 68Ga (FBP14, 68Ga-NODAGA), 111In (FBP15, 111In-DOTA-MA), or 99mTc (FBP16, 99mTc(CO)3-DETA-PA), respectively. PET or SPECT imaging, biodistribution, pharmacokinetics, and metabolic stability were evaluated in rat models of mural and occlusive carotid artery thrombosis. In vivo target specificity was evaluated by comparing the distribution of the SPECT and PET probes with preformed 125I-labeled thrombi and with a nonbinding control probe using SPECT/PET/CT imaging. All 3 radiotracers showed affinity similar to soluble fibrin fragment DD(E) (inhibition constant=0.53-0.83 μM). After the kidneys, the highest uptake of 68Ga-FBP14 and 111In-FBP15 was in the thrombus (1.0±0.2 percentage injected dose per gram), with low off-target accumulation. Both radiotracers underwent fast systemic elimination (half-life, 8-15 min) through the kidneys, which led to highly conspicuous thrombi on PET and SPECT images. 99mTc-FBP16 displayed low target uptake and distribution consistent with aggregation or degradation. Triple-isotope imaging experiments showed that both 68Ga-FBP14 and 111In-FBP15, but not the nonbinding derivative 64Cu-D-Cys-FBP8, detected the location of the 125I-labeled thrombus, confirming high target specificity. 68Ga-FBP14 and 111In-FBP15 have high fibrin affinity and thrombus specificity and represent useful PET and SPECT probes for thrombus detection. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Kong, Benjamin Y; Menzies, Alexander M; Saunders, Catherine A B; Liniker, Elizabeth; Ramanujam, Sangeetha; Guminski, Alex; Kefford, Richard F; Long, Georgina V; Carlino, Matteo S
2016-09-01
18-Fluorodeoxyglucose positron emission tomography (FDG-PET) scans were performed on 27 patients with unresectable stage IIIC or IV melanoma after prolonged treatment with anti-PD-1 antibodies to examine the hypothesis that patients with prolonged response to treatment may have metabolically inactive lesions by FDG-PET. Scans were performed at a median of 15.2 months (range 12-29 months) after starting treatment. Overall, 15 of 27 (56%) patients had a positive FDG-PET scan. Eight patients with positive scans underwent biopsy; 5 of 8 (62%) were melanoma and 3 of 8 (38%) were immune cell infiltrates. Of the 12 patients with negative FDG-PET scans, six had residual computerized tomography-visible lesions, five have ceased treatment, and none have recurred with follow-up of 6-10 months. Patients with residual metastases after a prolonged period without progression on anti-PD-1 therapy may have metabolically inactive lesions. Isolated metabolically active lesions in clinically well patients may reveal immune cell infiltrates rather than melanoma. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
In-beam PET data characterization with the large area DoPET prototype
NASA Astrophysics Data System (ADS)
Sportelli, G.; Belcari, N.; Camarlinghi, N.; Ciocca, M.; Collini, F.; Molinelli, S.; Pullia, M.; Zaccaro, E.; Del Guerra, A.; Rosso, V.
2016-02-01
Range verification with in-beam PET techniques is a powerful tool for monitoring the correctness of dose delivery in particle therapy. Among the major limitations of in-beam PET systems are the limited detectors size due to the constrained space in which they can be placed to allow the irradiation, and the necessity of a high read-out modularization, due to high activity rates during the irradiation. In this work we present the data acquired at the CNAO (Centro Nazionale di Adroterapia Oncologica) treatment center in Pavia, Italy, with the new DoPET system, specifically designed to operate in in-beam conditions. The new prototype consists of two planar 15cm × 15cm LYSO-based detectors, read out by 9 PMT detector modules each. In particular, we test the capability of our system to determine particle range in various irradiation conditions. Several plastic phantoms were irradiated at the CNAO treatment centre with protons and carbon ions of various energies. The used dose in treatment plans is 2 Gy and the monitoring feedback is produced in a few minutes after the end of the treatment.
NASA Astrophysics Data System (ADS)
Leen, J. B.; Gupta, M.
2014-12-01
Nitrate contamination in water is a worldwide environmental problem and source apportionment is critical to managing nitrate pollution. Fractionation caused by physical, chemical and biological processes alters the isotope ratios of nitrates (15N/14N, 18O/16O and 17O/16O) and biochemical nitrification and denitrification impart different intramolecular site preference (15N14NO vs. 14N15NO). Additionally, atmospheric nitrate is anomalously enriched in 17O compared to other nitrate sources. The anomaly (Δ17O) is conserved during fractionation processes, providing a tracer of atmospheric nitrate. All of these effects can be used to apportion nitrate in soil. Current technology for measuring nitrate isotopes is complicated and costly - it involves conversion of nitrate to nitrous oxide (N2O), purification, preconcentration and measurement by isotope ratio mass spectrometer (IRMS). Site specific measurements require a custom IRMS. There is a pressing need to make this measurement simpler and more accessible. Los Gatos Research has developed a next generation mid-infrared Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) analyzer to quantify all stable isotope ratios of N2O (δ15N, δ15Nα, δ15Nβ, δ18O, δ17O). We present the latest performance data demonstrating the precision and accuracy of the OA-ICOS based measurement. At an N2O concentration of 322 ppb, the analyzer quantifies [N2O], δ15N, δ15Na, δ15Nb, and δ18O with a precision of ±0.05 ppb, ±0.4 ‰, ±0.45 ‰, and ±0.6 ‰, and ±0.8 ‰ respectively (1σ, 100s; 1σ, 1000s for δ18O). Measurements of gas standards demonstrate accuracy better than ±1 ‰ for isotope ratios over a wide dynamic range (200 - 100,000 ppb). The measurement of δ17O requires a higher concentration (1 - 50 ppm), easily obtainable through conversion of nitrates in water. For 10 ppm of N2O, the instrument achieves a δ17O precision of ±0.05 ‰ (1σ, 1000s). This performance is sufficient to quantify atmospheric nitrate in soil and groundwater and may be used to differentiate other sources of nitrate for which the range of Δ17O values is much smaller. By measuring δ15N, δ15Nα, δ15Nβ, δ18O and δ17O, our instrument will help researchers unravel the complicated nitrate mixing problem to determine the sources and sinks of nitrate pollution.
Whitbeck, David E.
2006-01-01
The Lamoreux Potential Evapotranspiration (LXPET) Program computes potential evapotranspiration (PET) using inputs from four different meteorological sources: temperature, dewpoint, wind speed, and solar radiation. PET and the same four meteorological inputs are used with precipitation data in the Hydrological Simulation Program-Fortran (HSPF) to simulate streamflow in the Salt Creek watershed, DuPage County, Illinois. Streamflows from HSPF are routed with the Full Equations (FEQ) model to determine water-surface elevations. Consequently, variations in meteorological inputs have potential to propagate through many calculations. Sensitivity of PET to variation was simulated by increasing the meteorological input values by 20, 40, and 60 percent and evaluating the change in the calculated PET. Increases in temperatures produced the greatest percent changes, followed by increases in solar radiation, dewpoint, and then wind speed. Additional sensitivity of PET was considered for shifts in input temperatures and dewpoints by absolute differences of ?10, ?20, and ?30 degrees Fahrenheit (degF). Again, changes in input temperatures produced the greatest differences in PET. Sensitivity of streamflow simulated by HSPF was evaluated for 20-percent increases in meteorological inputs. These simulations showed that increases in temperature produced the greatest change in flow. Finally, peak water-surface elevations for nine storm events were compared among unmodified meteorological inputs and inputs with values predicted 6, 24, and 48 hours preceding the simulated peak. Results of this study can be applied to determine how errors specific to a hydrologic system will affect computations of system streamflow and water-surface elevations.
Weise, Christopher M; Thiyyagura, Pradeep; Reiman, Eric M; Chen, Kewei; Krakoff, Jonathan
2015-06-01
Little is known on how sensing of energy needs is centrally represented, integrated, and translated into the behavioral aspects of energy homeostasis. Fat free mass (FFM) is the major determinant of energy expenditure. We investigated how interindividual variances in FFM relate to neuronal activity in humans. Healthy adults (n = 64, 21F/43M; age 31.3 ± 9.1y; percentage of body fat [PFAT] 25.6 ± 10.7%; BMI 30.4 ± 9) underwent a 36h fast and subsequent H(2) (15) O positron emission tomographic (PET) measurement of regional cerebral blood flow (rCBF). Multiple variable regression analysis revealed significant associations of FFM with rCBF within the midbrain [including parts of the periaqueductal gray (PAG), ventral tegmental area (VTA), thalamic and hypothalamic regions], the bilateral parahippocampal region, left anterior cingulate, left insular cortex, right cerebellum, and distinct regions within the temporal and occipital cortex. In contrast, no significant associations were found for fat mass (FM). We investigated the potential functional-anatomical link between FFM and central regulation of food intake by performing a conjunction analysis of FFM and the perceived hunger feelings. This showed a significant overlap within the midbrain PAG. Mediation analysis demonstrated a significant indirect effect of FFM on hunger with PAG rCBF as mediator. Most regions we found to be associated with FFM form part in ascending homeostatic pathways and cortical circuitries implicated in the regulation of basic bodily functions indicating a potential role of these central networks in the integration of FFM determined energy needs. © 2015 Wiley Periodicals, Inc.
Visschers, Naomi C A; Hulzebos, Erik H; van Brussel, Marco; Takken, Tim
2015-11-01
The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT. CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included. No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs. The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Beck, Roswitha; Günther, Lisa; Xiong, Guoming; Potschka, Heidrun; Böning, Guido; Bartenstein, Peter; Brandt, Thomas; Jahn, Klaus; Dieterich, Marianne; Strupp, Michael; la Fougère, Christian; Zwergal, Andreas
2014-11-01
Early symptomatic treatment of acute unilateral vestibulopathy is thought to impede the course of ensuing central vestibular compensation (VC). Despite the great clinical importance of this hypothesis there is no experimental evidence of its validity. The present study addressed this question by investigating the direct effect of 4-aminopyridine (4-AP) on ocular motor and postural symptoms in acute unilateral vestibulopathy as well as its long-term consequences for VC in a rat model of chemical unilateral labyrinthectomy (UL). After UL, one group of Sprague-Dawley rats was treated with 4-AP p.o. (1mg/kg/day), another with 0.9% NaCl solution p.o. for 3days. Behavioural testing for symptoms of vestibular tone imbalance was done 1day before and 1, 2, 3, 5, 7, 9, 15, 21, and 30days after UL. In addition, sequential whole-brain [(18)F]-FDG-μPET was performed before and 1, 3, 7, 15, and 30days after UL to examine and visualize 4-AP-induced modulation of VC. Administration of 4-AP on days 1-3 significantly improved postural imbalance 2h after administration compared to that in controls. This effect was only transient. Remarkably, the 4-AP group had a prolonged and impaired course of postural compensation compared to that of controls. The μPET revealed a significant increase of regional cerebral glucose metabolism (rCGM) in the vestibulocerebellum 2h after administration of 4-AP. However, the 4-AP group exhibited a persistent asymmetry of rCGM after day 3 in the vestibular nuclei and posterolateral thalami. In conclusion, this study confirms the hypothesis that early pharmacological abatement of vestibular symptoms impedes VC. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mulholland, G.K.; Zheng, Q.H.; Zhou, F.C.
1996-05-01
There is considerable interest in measuring serotonin (5HT) and dopamine (DA) function in the human brain. Altered levels of 5HT and DA are recognized in drug abuse, neurotoxicities, psychiatric disorders, and neurodegenerative conditions including Alzheimer`s and Parkinson`s disease. Several phenyltropane analogs of cocaine bind tightly to both DA and 5HT uptake proteins. We have made a new agent from this class called {beta}CNT, 2{beta}-carboxymethyl-3{beta}-(2-naphthyl)-tropane, the isosteric O-for-CH{sub 2} analog of a compound reported to have among the highest measured affinities for DA and 5HT transporters and studied its in vivo brain distributions in animals for the first time. Optically puremore » {beta}CNT was made from cocaine, and labeled at the O-methyl position by esterification of {beta}CNT-acid with [C-11]CH{sub 3}OTfl under conditions similar to Wilson`s. HPLC-purified (99+%) final products (15-50% eob yield from CO{sub 2}, 40 min synth) had specific activities 0.1-1.2 Ci/{mu}mol at the time of injection. Preliminary [C-11]{beta}{beta}CNT rodent distribution showed very high brain uptake (3% ID at 60 min) and localization (striat: fr cort: hypo: cer: blood, 11: 5: 4: 1: 06). {beta}CNT-PET studies in juvenile pigs (5-20 mCi, 20-35 kg) found rapid brain uptake, and prominent retention (85 min) in midbrain, anterior brainstem and striatum, followed by cortex and olfactory bulb. Paroxetine pretreatment (5HT uptake blocker, 2mg/kg), diminished retention in most brain areas; nomifensine (DA/NE uptake blocker, 6 mg/kg) reduced striatum selectively. Direct comparisons of [C-11]{beta}CNT with other PET transporter radioligands {beta}CFT, {beta}CIT, and {beta}CTT (RTI-32) in the same pig found {beta}CNT had highest overall brain uptake among the agents. These initial results suggest {beta}CNT has favorable properties for imaging both 5HT and DA transporters in vivo, and further evaluation of its potential as a human PET agent is warranted.« less
Baumjohann, Nina; Harms, Diedrich
2015-01-01
During storage, acetaldehyde migration from polyethylene terephthalate (PET) bottles can affect the quality of mineral water even in the low µg l(-1) range negatively, as it features a fruity or plastic-like off-flavour. For a sensitive and fast analysis of acetaldehyde in mineral water, a new analysis method of 2,4-dinitrophenylhydrazine (DNPH) derivatisation followed by HPLC-electrospray tandem mass spectrometry (ESI-MS/MS) was developed. Acetaldehyde was directly derivatised in the mineral water sample avoiding extraction and/or pre-concentration steps and then analysed by reversed-phase HPLC-ESI-MS/MS using multiple reaction monitoring mode (MRM). Along with method development, the optimum molar excess of DNPH in contrast to acetaldehyde was studied for the mineral water matrix, because no specific and robust data were yet available for this critical parameter. Best results were obtained by using a calibration via the derivatisation reaction. Without any analyte enrichment or extraction, an LOD of 0.5 µg l(-1) and an LOQ of 1.9 µg l(-1) were achieved. Using the developed method, mineral water samples packed in PET bottles from Germany were analysed and the correlation between the acetaldehyde concentration and other characteristics of the samples was evaluated illustrating the applicability of the method. Besides a relationship between bottle size and CO2 content of the mineral water and acetaldehyde migration, a correlation with acetaldehyde migration and the material composition of the bottle, e.g. recycled PET, was noted. Investigating the light influence on the acetaldehyde migration with a newly developed, reproducible light exposure setup, a significant increase of the acetaldehyde concentration in carbonated mineral water samples was observed.
Chiao, P C; Rogers, W L; Fessler, J A; Clinthorne, N H; Hero, A O
1994-01-01
The authors have previously developed a model-based strategy for joint estimation of myocardial perfusion and boundaries using ECT (emission computed tomography). They have also reported difficulties with boundary estimation in low contrast and low count rate situations. Here they propose using boundary side information (obtainable from high resolution MRI and CT images) or boundary regularization to improve both perfusion and boundary estimation in these situations. To fuse boundary side information into the emission measurements, the authors formulate a joint log-likelihood function to include auxiliary boundary measurements as well as ECT projection measurements. In addition, they introduce registration parameters to align auxiliary boundary measurements with ECT measurements and jointly estimate these parameters with other parameters of interest from the composite measurements. In simulated PET O-15 water myocardial perfusion studies using a simplified model, the authors show that the joint estimation improves perfusion estimation performance and gives boundary alignment accuracy of <0.5 mm even at 0.2 million counts. They implement boundary regularization through formulating a penalized log-likelihood function. They also demonstrate in simulations that simultaneous regularization of the epicardial boundary and myocardial thickness gives comparable perfusion estimation accuracy with the use of boundary side information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... production process for the manufacture of low density polyethylene in which a reaction pressure of about 15... terephthalate) (PET) manufacture using dimethyl terephthalate means the manufacturing of poly(ethylene.... Poly(ethylene terephthalate) (PET) manufacture using terephthalic acid means the manufacturing of poly...
2015-01-01
Multimodal nanoparticulate materials are described, offering magnetic, radionuclide, and fluorescent imaging capabilities to exploit the complementary advantages of magnetic resonance imaging (MRI), positron emission tomography/single-photon emission commuted tomography (PET/SPECT), and optical imaging. They comprise Fe3O4@NaYF4 core/shell nanoparticles (NPs) with different cation dopants in the shell or core, including Co0.16Fe2.84O4@NaYF4(Yb, Er) and Fe3O4@NaYF4(Yb, Tm). These NPs are stabilized by bisphosphonate polyethylene glycol conjugates (BP-PEG), and then show a high transverse relaxivity (r2) up to 326 mM–1 s–1 at 3T, a high affinity to [18F]-fluoride or radiometal-bisphosphonate conjugates (e.g., 64Cu and 99mTc), and fluorescent emissions from 500 to 800 nm under excitation at 980 nm. The biodistribution of intravenously administered particles determined by PET/MR imaging suggests that negatively charged Co0.16Fe2.84O4@NaYF4(Yb, Er)-BP-PEG (10K) NPs cleared from the blood pool more slowly than positively charged NPs Fe3O4@NaYF4(Yb, Tm)-BP-PEG (2K). Preliminary results in sentinel lymph node imaging in mice indicate the advantages of multimodal imaging. PMID:26172432
El Essawy, Noha A; Konsowa, Abdelaziz H; Elnouby, Mohamed; Farag, Hassan A
2017-03-01
Nowadays our planet suffers from an accumulation of plastic products that have the potential to cause great harm to the environment in the form of air, water, and land pollution. Plastic water bottles have become a great problem in the environment because of the large numbers consumed throughout the world. Certain types of plastic bottles can be recycled but most of them are not. This paper describes an economical solvent-free process that converts polyethylene terephthalate (PET) bottles waste into carbon nanostructure materials via thermal dissociation in a closed system under autogenic pressure together with additives and/or catalyst, which can act as cluster nuclei for carbon nanostructure materials such as fullerenes and carbon nanotubes. This research succeeded in producing and controlling the microstructure of various forms of carbon nanoparticles from the PET waste by optimizing the preparation parameters in terms of time, additives, and amounts of catalyst. Plastic water bottles are becoming a growing segment of the municipal solid waste stream in the world; some are recycled but many are left in landfill sites. Recycling PET bottles waste can positively impact the environment in several ways: for instance, reduced waste, resource conservation, energy conservation, reduced greenhouse gas emissions, and decreasing the amount of pollution in air and water sources. The main novelty of the present work is based on the acquisition of high-value carbon-based nanomaterials from PET waste by a simple solvent-free chemical technique. Thus, the prepared materials are considered to be promising, cheap, eco-friendly materials that may find use in different applications.
NASA Astrophysics Data System (ADS)
Sakaike, Kohei; Akazawa, Muneki; Nakagawa, Akitoshi; Higashi, Seiichiro
2015-04-01
A novel low-temperature technique for transferring a silicon-on-insulator (SOI) layer with a midair cavity (supported by narrow SiO2 columns) by meniscus force has been proposed, and a single-crystalline Si (c-Si) film with a midair cavity formed in dog-bone shape was successfully transferred to a poly(ethylene terephthalate) (PET) substrate at its heatproof temperature or lower. By applying this proposed transfer technique, high-performance c-Si-based complementary metal-oxide-semiconductor (CMOS) transistors were successfully fabricated on the PET substrate. The key processes are the thermal oxidation and subsequent hydrogen annealing of the SOI layer on the midair cavity. These processes ensure a good MOS interface, and the SiO2 layer works as a “blocking” layer that blocks contamination from PET. The fabricated n- and p-channel c-Si thin-film transistors (TFTs) on the PET substrate showed field-effect mobilities of 568 and 103 cm2 V-1 s-1, respectively.
Blending Cr 2O 3 into a NiO-Ni electrocatalyst for sustained water splitting
Gong, Ming; Zhou, Wu; Kenney, Michael James; ...
2015-08-24
The rising H 2 economy demands active and durable electrocatalysts based on low-cost, earth-abundant materials for water electrolysis/photolysis. Here we report nanoscale Ni metal cores over-coated by a Cr 2O 3-blended NiO layer synthesized on metallic foam substrates. The Ni@NiO/Cr 2O 3 triphase material exhibits superior activity and stability similar to Pt for the hydrogen-evolution reaction in basic solutions. The chemically stable Cr 2O 3 is crucial for preventing oxidation of the Ni core, maintaining abundant NiO/Ni interfaces as catalytically active sites in the heterostructure and thus imparting high stability to the hydrogen-evolution catalyst. The highly active and stable electrocatalystmore » enables an alkaline electrolyzer operating at 20 mA cm –2 at a voltage lower than 1.5 V, lasting longer than 3 weeks without decay. Thus, the non-precious metal catalysts afford a high efficiency of about 15 % for light-driven water splitting using GaAs solar cells.« less
NASA Astrophysics Data System (ADS)
Wicaksono, Sigit Tri; Ardhyananta, Hosta; Rasyida, Amaliya
2018-04-01
Base on Sidoarjo's goverment data, there was more than 4000 metric ton perday of waste that has been accumulated during 2016. More than 10 percent from overall waste is plastics. In accordance with the Indonesia government regulation, "Indonesia clean from waste" by 2020 through 3R (Reduce, Reuse and Recycle) program, we have been focusing research on how to reduce the accumulation of the plastics waste in Sidoarjo by processing it become a new product. In this research, we have made the plastic waste of PET bottle as additional fillers or agregates of composite material for construction application as a paving block. The composition of PET plastic used as fillers is vary from 0, 10, 20, 30, 40 and 50% from total volume of agregates. The ratio of cement binder to sands agregate is 1:3. The specimens were characterized its mechanical and physical properties by using flexural testing, compressive testing, density and water absorbance measurement. The results show that the mechanical (flexural and compressive) properties of composite materials is increased significantly by increasing PET fillers up to 20%, however it was decreased when PET content more than 20%. But, both the density and water absobance of specimens are decreased by increasing of PET fillers.
Shelley, E B; O'Rourke, D; Grant, K; McArdle, E; Capra, L; Clarke, A; McNamara, E; Cunney, R; McKeown, P; Amar, C F L; Cosgrove, C; Fitzgerald, M; Harrington, P; Garvey, P; Grainger, F; Griffin, J; Lynch, B J; McGrane, G; Murphy, J; Ni Shuibhne, N; Prosser, J
2015-02-01
We describe two cases of infant botulism due to Clostridium butyricum producing botulinum type E neurotoxin (BoNT/E) and a previously unreported environmental source. The infants presented at age 11 days with poor feeding and lethargy, hypotonia, dilated pupils and absent reflexes. Faecal samples were positive for C. butyricum BoNT/E. The infants recovered after treatment including botulism immune globulin intravenous (BIG-IV). C. butyricum BoNT/E was isolated from water from tanks housing pet 'yellow-bellied' terrapins (Trachemys scripta scripta): in case A the terrapins were in the infant's home; in case B a relative fed the terrapin prior to holding and feeding the infant when both visited another relative. C. butyricum isolates from the infants and the respective terrapin tank waters were indistinguishable by molecular typing. Review of a case of C. butyricum BoNT/E botulism in the UK found that there was a pet terrapin where the infant was living. It is concluded that the C. butyricum-producing BoNT type E in these cases of infant botulism most likely originated from pet terrapins. These findings reinforce public health advice that reptiles, including terrapins, are not suitable pets for children aged <5 years, and highlight the importance of hand washing after handling these pets.
NASA Astrophysics Data System (ADS)
Zakhnini, Abdelhamid; Kulenkampff, Johannes; Sauerzapf, Sophie; Pietrzyk, Uwe; Lippmann-Pipke, Johanna
2013-08-01
Understanding conservative fluid flow and reactive tracer transport in soils and rock formations requires quantitative transport visualization methods in 3D+t. After a decade of research and development we established the GeoPET as a non-destructive method with unrivalled sensitivity and selectivity, with due spatial and temporal resolution by applying Positron Emission Tomography (PET), a nuclear medicine imaging method, to dense rock material. Requirements for reaching the physical limit of image resolution of nearly 1 mm are (a) a high-resolution PET-camera, like our ClearPET scanner (Raytest), and (b) appropriate correction methods for scatter and attenuation of 511 keV—photons in the dense geological material. The latter are by far more significant in dense geological material than in human and small animal body tissue (water). Here we present data from Monte Carlo simulations (MCS) reflecting selected GeoPET experiments. The MCS consider all involved nuclear physical processes of the measurement with the ClearPET-system and allow us to quantify the sensitivity of the method and the scatter fractions in geological media as function of material (quartz, Opalinus clay and anhydrite compared to water), PET isotope (18F, 58Co and 124I), and geometric system parameters. The synthetic data sets obtained by MCS are the basis for detailed performance assessment studies allowing for image quality improvements. A scatter correction method is applied exemplarily by subtracting projections of simulated scattered coincidences from experimental data sets prior to image reconstruction with an iterative reconstruction process.
... water containers like pet and animal watering containers, flower planter dishes or cover water storage barrels. Look ... water indoors such as in vases with fresh flowers and clean at least once a week. The ...
Calcite precipitates in Slovenian bottled waters.
Stanič, Tamara Ferjan; Miler, Miloš; Brenčič, Mihael; Gosar, Mateja
2017-06-01
Storage of bottled waters in varying ambient conditions affects its characteristics. Different storage conditions cause changes in the initial chemical composition of bottled water which lead to the occurrence of precipitates with various morphologies. In order to assess the relationship between water composition, storage conditions and precipitate morphology, a study of four brands of Slovenian bottled water stored in PET bottles was carried out. Chemical analyses of the main ions and measurements of the physical properties of water samples were performed before and after storage of water samples at different ambient conditions. SEM/EDS analysis of precipitates was performed after elapsed storage time. The results show that the presence of Mg 2+ , SO 4 2- , SiO 2 , Al, Mn and other impurities such as K + , Na + , Ba and Sr in the water controlled precipitate morphology by inhibiting crystal growth and leading to elongated rhombohedral calcite crystal forms which exhibit furrowed surfaces and calcite rosettes. Different storage conditions, however, affected the number of crystallization nuclei and size of calcite crystals. Hollow calcite spheres composed of cleavage rhombohedrons formed in the water with variable storage conditions by a combination of evaporation and precipitation of water droplets during high temperatures or by the bubble templating method.
NASA Astrophysics Data System (ADS)
Steele, M.; Aitkenhead-Peterson, J. A.
2009-12-01
High nitrogen (N) and phosphorus (P) watershed loading rates increases the concentration and loads present in urban streams and rivers, resulting in eutrophication and degradation of surface water quality. Domestic pet animal feed may represent a significant proportion of nitrogen loading in urban watersheds, and because it is deposited directly on the watershed surface may have a large effect on N loads in urban surface waters (Baker et al. 2001). Animal manure has long been used to increase soil N and phosphorus concentrations for the purpose of growing agricultural crops; however, little is known about unintentional urban manuring resulting from a high density of domesticated pets. The purpose of this study is to determine if the presence of domesticated animals in high density urban developments results in increased concentrations of soil dissolved organic carbon (DOC), N, and P and the potential to contribute to loading of urban streams. Composite soil samples from the 0 to 5 cm and 5 to 10 cm soil depth were collected from apartment complexes in Bryan/College Station (BCS) and San Antonio, Texas during August, 2009. Apartment complexes were randomly located around the city and were chosen based on their rules regarding pet ownership. Four apartment complexes that allowed all domestic pets were compared to four that did not allow any domestic pets on the property. A 10:1 water extraction of field moist soil was conducted immediately after sampling. Soil water extracts were analyzed for DOC, total dissolved nitrogen (TDN), nitrate-N, ammonium-N, dissolved organic N, and orthophosphate-P. Results indicated significantly increased concentrations of DOC and N species at both depths in BCS apartments that allowed pets compared to those that did not; however, opposite trends were found in San Antonio. There is a trend for increased concentrations of orthophosphate-P at both locations. Baker, L.A., D. Hope, Y. Xu, et al. 2001. Nitrogen balance for the central Arizona-Phoenix (CAP) ecosystem. Ecosystems 4: 582-602.
Neural correlates for perception of companion animal photographs.
Hayama, Sara; Chang, Linda; Gumus, Kazim; King, George R; Ernst, Thomas
2016-05-01
Anthrozoological neuroscience, which we propose as the use of neuroscience techniques to study human-animal interaction, may help to elucidate mechanisms underlying the associated psychological, physiological, and other purported health effects. This preliminary study investigates the neural response to animal photographs in pet owners and non-pet owners, and both attraction and attachment to companion animals as modulators of human perception of companion animal photographs. Thirty male participants, 15 "Pet Owners" (PO) and 15 "Non-Pet Owners" (NPO), viewed photographs of companion animals during functional MRI (fMRI) scans at 3 T and provided ratings of attraction to the animal species represented in the photographs. Fourteen subjects additionally submitted and viewed personal pet photographs during fMRI scans, and completed the Lexington Attachment to Pets Scale (LAPS). PO exhibited greater activation than NPO during the viewing of animal photographs in areas of the insula, and frontal and occipital cortices. Moreover, ratings of attraction to animals correlated positively with neural activation in the cingulate gyrus, precentral gyrus, inferior parietal lobule, and superior temporal gyrus during the viewing of representative photographs. For subjects with household pets, scores on the LAPS correlated positively with neural activation during the viewing of owned pet photographs in the precuneus, cuneus, and superior parietal lobule. Our preliminary findings suggest that human perception of companion animals involve the visual attention network, which may be modulated at the neural level by subjective experiences of attraction or attachment to animals. Our understanding of human-animal interactions through anthrozoological neuroscience may better direct therapeutic applications, such as animal-assisted therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.
OH in Rutile: an Oxygen and Water Barometer
NASA Astrophysics Data System (ADS)
Johnson, E. A.; Manning, C. E.; Antignano, A.; Tropper, P.
2005-12-01
Dehydration of the subducting lithosphere induces oxidation and partial melting in the mantle wedge above subduction zones, and storage of water in the form of hydroxyl in high-pressure mineral phases may be an important mechanism for transfer of water to the mantle. It is therefore important to quantify water content of fluids and oxygen fugacity in subduction zones, but these variables can be difficult to measure or infer in many rocks. This study investigates the possibility of determining oxygen fugacity or water activity based on OH concentration measurements in rutile. The solubility of OH in pure rutile has been determined using rutile grains from aqueous fluid solubility experiments (Tropper and Manning 2005, Am Min, 90, 502). In pure rutile, H+ is stoichiometrically incorporated into the structure via reduction of Ti4+ to Ti3+, resulting in a change in color from pale yellow to deep blue. Synthetic rutile crystals were equilibrated in pure H2O or a H2O-NaCl solution at 1-2 GPa and 600-1100°C. The runs were unbuffered with respect to oxygen fugacity but were close to the NNO buffer (Newton and Manning 2005, J Petr, 46, 701). Rutile OH concentrations were determined using FTIR spectroscopy and the calibration of Maldener (2001, Min Pet, 71, 21). At a constant pressure of 1 GPa, OH concentrations of rutile in equilibrium with pure H2O increase exponentially from 600 to 1100°C. The data are fit with the equation [OH] = 17.7exp(4.00×10-3T) (R=0.998), where [OH] is in ppm H2O wt. and T is in °C. Increasing pressure from 1 to 2 GPa at 1100°C results in an increase in OH solubility from 1540 to 2220 ppm H2O. OH solubility in rutile decreases from 2220 to 1290 ppm H2O by lowering the water activity of the fluid from 1 to 0.49 at P = 2 GPa and T = 1100°C. Using the solubility data and the exchange reaction, Ti3+O(OH) + O2 = Ti4+O2 + <
Hideghéty, Katalin; Cserháti, Adrienne; Besenyi, Zsuzsanna; Zag, Levente; Gaál, Szilvia; Együd, Zsófia; Mózes, Petra; Szántó, Erika; Csenki, Melinda; Rusz, Orsolya; Varga, Zoltán; Dobi, Ágnes; Maráz, Anikó; Pávics, László; Lengyel, Zsolt
2015-06-01
The purpose of our work is evaluation of the impact of 18FDG-PET/CT on the complex management of locoregionally advanced (T3-4N1-3) head and neck squamous cell cancer (LAHNSC), and on the target definition for 3D conformal (3DCRT) and intensity-modulated radiotherapy (IMRT). 18FDG-PET/CT were performed on 185 patients with LAHNSC prior to radiotherapy/chemoradiation in the treatment position between 2006 and 2011. Prior to it 91 patients received induction chemotherapy (in 20 cases of these, baseline PET/CT was also available). The independently delineated CT-based gross tumor volume (GTVct) and PET/CT based ones (GTVpet) were compared. Impact of PET/CT on the treatment strategy, on tumor response evaluation to ICT, on GTV definition furthermore on overall and disease-specific survival (OS, DSS) was analysed. PET/CT revealed 10 head and neck, 2 lung cancers for 15 patients with carcinoma of unknown primary (CUP) while 3 remained unknown. Second tumors were detected in 8 (4.4%), distant metastasis in 15 (8.2%) cases. The difference between GTVct and GTVpet was significant (p=0.001). In 16 patients (14%) the GTVpet were larger than GTVct due to multifocal manifestations in the laryngo-pharyngeal regions (4 cases) or lymph node metastases (12 cases). In the majority of the cases (82 pts, 72%) PET/CT-based conturing resulted in remarkable decrease in the volume (15-20%: 4 cases, 20-50%: 46 cases, >50%: 32 cases). On the basis of the initial and post-ICT PET/CT comparison in 15/20 patients more than 50% volume reduction and in 6/20 cases complete response were achieved. After an average of 6.4 years of follow-up the OS (median: 18.3±2.6 months) and DSS (median: 25.0±4.0 months) exhibited close correlation (p=0.0001) to the GTVpet. In cases with GTVpet <10 cm3 prior to RT, DSS did not reach the median, the mean is 82.1±6.1 months, while in cases with GTVpet 10-40 cm3 the median of the DSS was 28.8±4.9 months (HR = 3.57; 95% CI: 1.5-8.3), and in those with GTVpet >40 cm3 the median DSS was 8.4±0.96 months (HR= 11.48; 95% CI: 5.3-24.9). Our results suggest that 18FDG-PET/CT plays an important role for patient with LAHNSC, by modifying the treatment concept and improving the target definition for selective RT modalities. Volumetric PET/CT-based assessment of the tumor response after ICT gives valuable contribution to further therapy planning.
Paquet, Marie; Gauthé, Mathieu; Zhang Yin, Jules; Nataf, Valérie; Bélissant, Ophélie; Orcel, Philippe; Roux, Christian; Talbot, Jean-Noël; Montravers, Françoise
2018-03-12
Oncogenic osteomalacia is an endocrine disorder induced by small benign tumours (TIO) producing excessive fibroblast growth factor-23 (FGF23). The only way of curing oncogenic osteomalacia is surgical resection of the culprit TIO, which is extremely difficult to detect using conventional imaging modalities due to its small size and variable location in the body. Since TIO frequently overexpress somatostatin receptors, a clinical utility of SPECT or PET with radiolabelled somatostatin analogues has been reported. Among them, 68 Ga-DOTA-TOC has recently been granted a marketing authorization, facilitating its routine application. We report here the results of the first series evaluating the diagnostic performance of 68 Ga-DOTA-TOC PET/CT in detecting TIO and its impact on patient management. 68 Ga-DOTA-TOC PET/CT and clinical and imaging data from 15 patients with clinical and biochemical signs of oncogenic osteomalacia were retrospectively reviewed. The 68 Ga-DOTA-TOC PET/CT findings were compared with the results of post-surgical pathology and clinical and biochemical follow-up. 68 Ga-DOTA-TOC PET/CT resulted in the detection of one focus suspicious for TIO in nine of 15 patients (60%), and a tumour was surgically removed in eight. Post-operative pathology confirmed a TIO in those eight patients whose symptoms diminished promptly and biochemical anomalies resolved. 68 Ga-DOTA-TOC PET/CT sensitivity, specificity and accuracy were 73%, 67% and 71%, respectively. 68 Ga-DOTA-TOC PET/CT findings affected patient management in 67% of cases. In particular, 68 Ga-DOTA-TOC PET/CT was able to detect the TIO with a negative or a false-positive result of a previous 111 In-pentetreotide SPECT/CT in 5/8 patients (63%) or a previous FDG PET/CT in 7/11 patients (64%). No close relationship was found between the positivity of 68 Ga-DOTA-TOC PET/CT and the serum level of a biochemical marker. However, a true-positive result of 68 Ga-DOTA-TOC PET/CT was obtained in only one patient with a non-elevated serum level of FGF23. 68 Ga-DOTA-TOC PET/CT is an accurate imaging modality in the detection of TIO; in particular, it is worthwhile after failure of somatostatin receptor SPECT(/CT) or FDG PET/CT.
Verger, Antoine; Filss, Christian P; Lohmann, Philipp; Stoffels, Gabriele; Sabel, Michael; Wittsack, Hans-J; Kops, Elena Rota; Galldiks, Norbert; Fink, Gereon R; Shah, Nadim J; Langen, Karl-Josef
2018-05-01
To compare the diagnostic performance of O-(2- 18 F-fluoroethyl)-L-tyrosine ( 18 F-FET) positron emission tomography (PET) and perfusion-weighted magnetic resonance imaging (PWI) for the diagnosis of progressive or recurrent glioma. Thirty-two pretreated gliomas (25 progressive or recurrent tumors, 7 treatment-related changes) were investigated with 18 F-FET PET and PWI via a hybrid PET/magnetic resonance scanner. Volumes of interest with a diameter of 16 mm were centered on the maximum of abnormality in the tumor area in PET and PWI maps (relative cerebral blood volume, relative cerebral blood flow, mean transit time) and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios as well as dynamic data for 18 F-FET uptake were calculated. Diagnostic accuracies were evaluated by receiver operating characteristic analyses, calculating the area under the curve. 18 F-FET PET showed a significant greater sensitivity to detect abnormalities in pretreated gliomas than PWI (76% vs. 52%, P = 0.03). The maximum tumor-to-brain ratio of 18 F-FET PET was the only parameter that discriminated treatment-related changes from progressive or recurrent gliomas (area under the curve, 0.78; P = 0.03, best cut-off 2.61; sensitivity 80%, specificity 86%, accuracy 81%). Among patients with signal abnormality in both modalities, 75% revealed spatially incongruent local hot spots. This pilot study suggests that 18 F-FET PET is superior to PWI to diagnose progressive or recurrent glioma. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Qian, Zhengmin (Min); Dong, Guang-Hui; Ren, Wan-Hui; Simckes, Maayan; Wang, Jing; Zelicoff, Alan; Trevathan, Edwin
2014-04-01
Previous studies examining pet ownership as a risk factor for respiratory conditions have yielded inconsistent results. Little is known about whether or not pet ownership modifies the relationship between air pollutants and respiratory symptoms and asthma in children. In order to evaluate the interaction between pet and air pollution on respiratory health in children, we recruited 30,149 children, aged 2-12 years, from 25 districts of seven cities in northeast China. Parents of the children completed questionnaires that characterized the children's histories of respiratory symptoms and illnesses and associated risk factors. Average ambient annual exposures to particulate matter with an aerodynamic diameter ≤10 μm (PM10), sulfur dioxide (SO2), nitrogen dioxide (NO2), and ozone (O3) were estimated from monitoring stations in each of the 25 study districts. The results showed that among children without pets at home, there were statistically significant associations between both recent exacerbations of asthma among physician-diagnosed asthmatics and respiratory symptoms and all pollutants examined. Odds ratios (ORs) ranged from 1.12 [95% confidence interval (CI), 1.00-1.26] to 1.41 (95% CI, 1.24-1.61) per 31 μg m-3 for PM10, whereas, among children with pets at home, there were no effects or small effects for either asthma or the symptoms. The interactions between dog ownership and PM10, SO2, NO2, and O3 were statistically significant, such that children with a dog at home had lower reporting of both current asthma and current wheeze. In conclusion, this study suggests that pet ownership decreased the effects of air pollution on respiratory symptoms and asthma among Chinese children.
A two-dimensional hydrogen-bonded water layer in the structure of a cobalt(III) cubane complex.
Qi, Ji; Zhai, Xiang-Sheng; Zhu, Hong-Lin; Lin, Jian-Li
2014-02-01
A tetranuclear Co(III) oxide complex with cubane topology, tetrakis(2,2'-bipyridine-κ(2)N,N')di-μ2-carbonato-κ(4)O:O'-tetra-μ3-oxido-tetracobalt(III) pentadecahydrate, [Co4(CO3)2O4(C10H8N2)4]·15H2O, with an unbounded hydrogen-bonded water layer, has been synthesized by reaction of CoCO3 and 2,2'-bipyridine. The solvent water molecules form a hydrogen-bonded net with tetrameric and pentameric water clusters as subunits. The Co4O4 cubane-like cores are sandwiched between the water layers, which are further stacked into a three-dimensional metallo-supramolecular network.
Pet ownership and adolescent health: cross-sectional population study.
Mathers, Megan; Canterford, Louise; Olds, Tim; Waters, Elizabeth; Wake, Melissa
2010-12-01
To determine whether adolescent health and well-being are associated with having a pet in the household (any pet, or specifically dogs, cats or horses/ponies) or average daily time spent caring for/playing with pet(s). Design, setting and participants--Cross-sectional data from the third wave of the Health of Young Victorians Study (HOYVS), a school-based population study in Victoria, Australia. Predictors--Adolescent-reported pet ownership and average daily time spent caring for/playing with pet(s). Outcomes--Self-reported quality of life (KIDSCREEN); average 4-day daily physical activity level from a computerised diary; parent-proxy and self-reported physical and psychosocial health status (PedsQL); measured BMI status (not overweight, overweight, obese) and blood pressure. Statistical Analysis--Regression methods, adjusted for socio-demographic factors, and non-parametric methods. Household pet data were available for 928 adolescents (466 boys; mean age of 15.9 (SD 1.2) years). Most adolescents (88.7%) reported having a pet in their household. Of these, 75.1% reported no activity involving pets over the surveyed days. It appeared that neither owning a pet nor time spent caring for/playing with a pet was related, positively or negatively, to adolescent health or well-being. Despite high rates of pet ownership, adolescents had little interaction with pets. It appears that owning a pet and time spent caring for/playing with a pet was not clearly associated with adolescents' health or well-being. © 2010 The Authors. Journal of Paediatrics and Child Health © 2010 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Basic study of entire whole-body PET scanners based on the OpenPET geometry
NASA Astrophysics Data System (ADS)
Yoshida, Eiji; Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo
2010-09-01
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.
NASA Astrophysics Data System (ADS)
Lima, F. Anderson S.; Beliatis, Michail J.; Roth, Bérenger; Andersen, Thomas R.; Bortoti, Andressa; Reyna, Yegraf; Castro, Eryza; Vasconcelos, Igor F.; Gevorgyan, Suren A.; Krebs, Frederik C.; Lira-Cantu, Mónica
2016-02-01
Solution processable semiconductor oxides have opened a new paradigm for the enhancement of the lifetime of thin film solar cells. Their fabrication by low-cost and environmentally friendly solution-processable methods makes them ideal barrier (hole and electron) transport layers. In this work, we fabricate flexible ITO-free organic solar cells (OPV) by printing methods applying an aqueous solution-processed V2O5 as the hole transport layer (HTL) and compared them to devices applying PEDOT:PSS. The transparent conducting electrode was PET/Ag/PEDOT/ZnO, and the OPV configuration was PET/Ag/PEDOT/ZnO/P3HT:PC60BM/HTL/Ag. Outdoor stability analyses carried out for more than 900 h revealed higher stability for devices fabricated with the aqueous solution-processed V2O5.
EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)
NASA Astrophysics Data System (ADS)
Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry
2016-04-01
Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.
NASA Astrophysics Data System (ADS)
Hou, Lei; Bi, Siyi; Zhao, Hang; Xu, Yumeng; Mu, Yuhang; Lu, Yinxiang
2017-05-01
High corrosion resistant Cu-Co-P coatings were firstly prepared on polyethylene terephthalate (PET) substrate by electroless plating in combination with UV/ozonolysis irradiation under optimized cobalt sulfate heptahydrate concentration, pH value, plating temperature and time. The copper polyalloy/PET composite can be obtained in three steps, namely: (i) the generation of oxygen-containing functionalities (carboxylic groups) onto PET surface through UV irradiation combined with ozone, (ii) Cu seeding catalysts were obtained after being immersed into cupric citrate and NaBH4 solutions subsequently, and (iii) Cu-Co-P polyalloy metallization using electroless plating bath. Attenuated total reflection fourier transformation infrared spectrometer (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), water contact angle measurement and energy dispersive X-ray analysis (EDAX) were utilized to track the surface changes during the whole process. The electroless plating conditions were optimized by an orthogonal experiment (L9(3)4) for Cu-Co-P coating as follows: CoSO4·7H2O addition of 0.08 M, pH value, plating temperature and time were set on 10.0, 35 °C and 25 min, respectively. Under the optimal conditions, copper polyalloy possessed high adhesive strength and the lowest surface resistance (8.06 Ω/sq), while maintaining reliability even after over 1000 times of bending and mechanical stress. The results of scanning electron microscope (SEM) and atomic force microscope (AFM) measurements showed that Cu-Co-P layer formed on PET surface was imparted with fine uniformity and high compactness. Electrochemical test revealed the optimized Cu-Co-P coatings exhibited high corrosion resistance in NaCl, NaOH and HCl solutions, respectively. The excellent electromagnetic interference shielding effectiveness (EMI SE >99.999% at frequency ranging from 30 MHz to 1000 MHz) of copper polyalloy/PET composites was confirmed by the spectrum analyzer. Therefore, this copper polyalloy will have potential applications in microelectronics packaging and coatings for anti-corrosion and electromagnetic interference shielding.
Eustache, F; Desgranges, B; Petit-Taboué, M C; de la Sayette, V; Piot, V; Sablé, C; Marchal, G; Baron, J C
1997-09-01
To assess explicit memory and two components of implicit memory--that is, perceptual-verbal skill learning and lexical-semantic priming effects--as well as resting cerebral blood flow (CBF) and oxygen metabolism (CMRO2) during the acute phase of transient global amnesia. In a 59 year old woman, whose amnestic episode fulfilled all current criteria for transient global amnesia, a neuropsychological protocol was administered, including word learning, story recall, categorical fluency, mirror reading, and word stem completion tasks. PET was performed using the (15)O steady state inhalation method, while the patient still exhibited severe anterograde amnesia and was interleaved with the cognitive tests. There was a clear cut dissociation between impaired long term episodic memory and preserved implicit memory for its two components. Categorical fluency was significantly altered, suggesting word retrieval strategy--rather than semantic memory--impairment. The PET study disclosed a reduced CMRO2 with relatively or fully preserved CBF in the left prefrontotemporal cortex and lentiform nucleus, and the reverse pattern over the left occipital cortex. The PET alterations with patchy CBF-CMRO2 uncoupling would be compatible with a migraine-like phenomenon and indicate that the isolated assessment of perfusion in transient global amnesia may be misleading. The pattern of metabolic depression, with sparing of the hippocampal area, is one among the distinct patterns of brain dysfunction that underlie the (apparently) uniform clinical presentation of transient global amnesia. The finding of a left prefrontal hypometabolism in the face of impaired episodic memory and altered verbal fluency would fit present day concepts from PET activation studies about the role of this area in episodic and semantic memory encoding/retrieval. Likewise, the changes affecting the lenticular nucleus but sparing the caudate would be consistent with the normal performance in perceptual-verbal skill learning. Finally, unaltered lexical-semantic priming effects, despite left temporal cortex hypometabolism, suggest that these processes are subserved by a more distributed neocortical network.
PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner.
Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I
2017-11-01
MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.
PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner
NASA Astrophysics Data System (ADS)
Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R.; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.
2017-11-01
MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.
The Effects of Cooking Process and Meat Inclusion on Pet Food Flavor and Texture Characteristics.
Koppel, Kadri; Gibson, Michael; Alavi, Sajid; Aldrich, Greg
2014-05-23
The pet food industry is an important portion of the food and feed industries in the US. The objectives of this study were (1) to determine cooking method (baking or extrusion), meat inclusion (0 or 20%), and extrusion thermal to mechanical energy ratios (low, medium, and high) effects on sensory and volatile properties of pet foods, and (2) to determine associations among sensory and volatile characteristics of baked and extruded pet foods. Descriptive sensory analysis and gas chromatography-mass spectrometry were used to analyze the pet food samples. It was found that baked samples were lighter in color (2.0-2.6 baked vs. 3.5-4.3 extruded, color intensity scale 0-15), and had lower levels of attributes that indicated rancidity (i.e., fishy flavor; 0.3-0.6 baked, 0.6-1.5 extruded, scale 0-15), whereas extruded pet foods were more cohesive in mass, more friable, hard, and crisp, but less powdery than baked samples. Fresh meat inclusion tended to decrease bitterness and increase fishy flavor and cohesiveness of pet foods. High thermal to mechanical energy ratio during extrusion resulted in less musty and more porous kibbles. The main volatile compounds included aldehydes, such as hexanal and heptanal, ketones, and alcohols. Extruded samples did not contain methylpyrazine, while baked samples did not contain 2-butyl furan. Future studies should consider evaluating the relationship between sensory results and animal palatability for these types of foods.
Eyeblink conditioning in unmedicated schizophrenia patients: A positron emission tomography study
Parker, Krystal L.; Andreasen, Nancy C.; Liu, Dawei; Freeman, John H.; O’Leary, Daniel S.
2014-01-01
Previous studies suggest that patients with schizophrenia exhibit dysfunctions in a widely distributed circuit—the cortico-cerebellar-thalamic-cortical circuit, or CCTCC—and that this may explain the multiple cognitive deficits observed in the disorder. This study uses positron emission tomography (PET) with O15 H2O to measure regional cerebral blood flow (rCBF) in response to a classic test of cerebellar function, the associative learning that occurs during eyeblink conditioning, in a sample of 20 unmedicated schizophrenia patients and 20 closely matched healthy controls. The PET paradigm examined three phases of acquisition and extinction (early, middle and late). The patients displayed impaired behavioral performance during both acquisition and extinction. The imaging data indicate that, compared to the control subjects, the patients displayed decreases in rCBF in all three components of the CCTCC during both acquisition and extinction. Specifically, patients had less rCBF in the middle and medial frontal lobes, anterior cerebellar lobules I/V and VI, as well as the thalamus during acquisition and although similar areas were found in the frontal lobe, ipsilateral cerebellar lobule IX showed consistently less activity in patients during extinction. Thus this study provides additional support for the hypothesis that patients with schizophrenia have a cognitive dysmetria—an inability to smoothly coordinate many different types of mental activity—that affects even a very basic cognitive task that taps into associative learning. PMID:24090512
Niccoli Asabella, Artor; Iuele, Francesca; Simone, Francesco; Fanelli, Margherita; Lavelli, Valentina; Ferrari, Cristina; Di Palo, Alessandra; Notaristefano, Antonio; Merenda, Nunzio Clemente; Rubini, Giuseppe
2015-01-01
Spondylodiscitis is characterized by infection involving the intervertebral disc and adjacent vertebrae. It can occur anywhere in the vertebral column but more commonly involves lumbar spine. Our aim was to evaluate the usefulness of (18)F-FDG PET/CT to detect the early response to antibiotic therapy in patients affected by infectious spondylodiscitis and to compare the role of (18)F-FDG PET/CT and MRI in post-treatment evaluation. 15 patients (12M, 3F), with mean age 65±13 years old, with typical clinical symptoms of Infectious Spondylodiscitis (pain, fever and increase of inflammatory indexes) and confirmed by blood culture or vertebral biopsy underwent within three day-interval a (18)F-FDG PET/CT and Magnetic Resonance (MR) at "baseline" and after antibiotic therapy. Semiquantitative parameters at (18)F-FDG PET/CT "baseline" SUVmax1, MTV1 and TLG1 and after therapy SUVmax2, MTV2 and TLG2 of involved vertebrae were calculated. Follow-up period of at least three months was available for all patients. T-student test for paired groups was performed to compare baseline and after therapy (18)F-FDG PET/CT semiquantitative parameters. According to (18)F-FDG PET/CT parameters all patients showed a response to antibiotic therapy. All patients were positive at "baseline" MRI of the spine, while at follow-up, 7/15 patients showed MR signs of infection and were considered "positive" and 8/15 showed resolution of infectious condition and, therefore they were considered "negative". A statistical significant difference between (18)F-FDG PET/CT "baseline" and after antibiotic therapy was found for all semiquantitative parameters: SUVmax (t=5.8, P=0.01); MTV (t=5.17, P=0.001); TLG (t=5,26, P=0,001). The comparison between the "baseline" and "after treatment" (18)F-FDG semiquantitative parameters showed a significant reduction of all parameters. This reduction was relevant also in patients with positive post-treatment MRI. This can be probably related to the tissue remodeling in the very immediate phase post-treatment, resulted positive at MRI and negative at (18)F-FDG PET/CT. Clinical follow-up of at least three months confirmed these results. (18)F-FDG PET/CT is useful to detect the early response to antibiotic therapy in patients affected by infectious spondylodiscitis. (18)F-FDG PET/CT semiquantitative parameters provide critical diagnostic information of the infectious process. (18)F-FDG PET/CT should be considered as first-line exam in the early post-treatment evaluation of spondylodiscitis while MR should be preferred for delayed assessment.
Galldiks, Norbert; Stoffels, Gabriele; Filss, Christian; Rapp, Marion; Blau, Tobias; Tscherpel, Caroline; Ceccon, Garry; Dunkl, Veronika; Weinzierl, Martin; Stoffel, Michael; Sabel, Michael; Fink, Gereon R; Shah, Nadim J; Langen, Karl-Josef
2015-09-01
We evaluated the diagnostic value of static and dynamic O-(2-[(18)F]fluoroethyl)-L-tyrosine ((18)F-FET) PET parameters in patients with progressive or recurrent glioma. We retrospectively analyzed 132 dynamic (18)F-FET PET and conventional MRI scans of 124 glioma patients (primary World Health Organization grade II, n = 55; grade III, n = 19; grade IV, n = 50; mean age, 52 ± 14 y). Patients had been referred for PET assessment with clinical signs and/or MRI findings suggestive of tumor progression or recurrence based on Response Assessment in Neuro-Oncology criteria. Maximum and mean tumor/brain ratios of (18)F-FET uptake were determined (20-40 min post-injection) as well as tracer uptake kinetics (ie, time to peak and patterns of the time-activity curves). Diagnoses were confirmed histologically (95%) or by clinical follow-up (5%). Diagnostic accuracies of PET and MR parameters for the detection of tumor progression or recurrence were evaluated by receiver operating characteristic analyses/chi-square test. Tumor progression or recurrence could be diagnosed in 121 of 132 cases (92%). MRI and (18)F-FET PET findings were concordant in 84% and discordant in 16%. Compared with the diagnostic accuracy of conventional MRI to diagnose tumor progression or recurrence (85%), a higher accuracy (93%) was achieved by (18)F-FET PET when a mean tumor/brain ratio ≥2.0 or time to peak <45 min was present (sensitivity, 93%; specificity, 100%; accuracy, 93%; positive predictive value, 100%; P < .001). Static and dynamic (18)F-FET PET parameters differentiate progressive or recurrent glioma from treatment-related nonneoplastic changes with higher accuracy than conventional MRI. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Practical experience and challenges in the operation of medical cyclotron.
Kumar, Rajeev; Sonkawade, Rajendra G; Pandey, Anil K; Tripathi, Madhavi; Damle, Nishikant A; Kumar, Praveen; Bal, Chandra S
2017-01-01
The aim of this article was to share 10 years of operational experience of medical cyclotron and to provide working knowledge on the same. This experience has helped us gain working knowledge on cyclotron operation with practical points, which may help in improving F yield, minimizing the breakdown time, and help in the prevention of the occurrence of unusual events. Our facility has a self-shielded radioisotope delivery system eclipse 111 medical cyclotron with an 11 MeV proton beam in use for the past 10 years to produce positron emitters - namely, F, N, and F-2 gas - for PET imaging. During F production, we have followed a set protocol comprising the following: monitoring target pressure, rinsing the target with O water just immediately after bombardment, ion source feedback, radiofrequency (RF) feedback, and recording any unusual events that occurred during the operation. Besides this, enrichment of O water, target volume, target current, energy of the beam, variation in argon pressure on the target, bombardment duration, target status (new or old target or total number of previous bombardments on the same target), status of the delivery lines from target to the radiochemistry module (old or new) were also recorded. Rinsing with O water immediately after bombardment increases the life of the target and delivery line. The frequent problems encountered were with the ion source, RF, and target foil rupture. These problems were solved by rebuilding the ion source, changing the fuse of RF, and rebuilding the target. F yield can be increased by rinsing with O water immediately after bombardment. The effect of target leak - that is, rupture of vacuum window - can be avoided by immediate stoppage of bombardment.
Improved LabPET Detectors Using Lu1.8Gd0.2SiO5:Ce (LGSO) Scintillator Blocks
NASA Astrophysics Data System (ADS)
Bergeron, Mélanie; Pepin, Catherine M.; Cadorette, Jules; Loignon-Houle, Francis; Fontaine, Réjean; Lecomte, Roger
2015-02-01
The scintillator is one of the key building blocks that critically determine the physical performance of PET detectors. The quest for scintillation crystals with improved characteristics has been crucial in designing scanners with superior imaging performance. Recently, it was shown that the decay time constant of high lutetium content Lu1.8Gd0.2SiO5: Ce (LGSO) scintillators can be adjusted by varying the cerium concentration from 0.025 mol% to 0.75 mol%, thus providing interesting characteristics for phoswich detectors. The high light output (90%-120% NaI) and the improved spectral match of these scintillators with avalanche photodiode (APD) readout promise superior energy and timing resolutions. Moreover, their improved mechanical properties, as compared to conventional LGSO ( Lu0.4Gd1.6SiO5: Ce), make block array manufacturing readily feasible. To verify these assumptions, new phoswich block arrays made of LGSO-90%Lu with low and high mol% Ce concentrations were fabricated and assembled into modules dedicated to the LabPET scanner. Typical crystal decay time constants were 31 ns and 47 ns, respectively. Phoswich crystal identification performed using a digital pulse shape discrimination algorithm yielded an average 8% error. At 511 keV, an energy resolution of 17-21% was obtained, while coincidence timing resolution between 4.6 ns and 5.2 ns was achieved. The characteristics of this new LGSO-based phoswich detector module are expected to improve the LabPET scanner performance. The higher stopping power would increase the detection efficiency. The better timing resolution would also allow the use of a narrower coincidence window, thus minimizing the random event rate. Altogether, these two improvements will significantly enhance the noise equivalent count rate performance of an all LGSO-based LabPET scanner.
Technical Note: Deep learning based MRAC using rapid ultra-short echo time imaging.
Jang, Hyungseok; Liu, Fang; Zhao, Gengyan; Bradshaw, Tyler; McMillan, Alan B
2018-05-15
In this study, we explore the feasibility of a novel framework for MR-based attenuation correction for PET/MR imaging based on deep learning via convolutional neural networks, which enables fully automated and robust estimation of a pseudo CT image based on ultrashort echo time (UTE), fat, and water images obtained by a rapid MR acquisition. MR images for MRAC are acquired using dual echo ramped hybrid encoding (dRHE), where both UTE and out-of-phase echo images are obtained within a short single acquisition (35 sec). Tissue labeling of air, soft tissue, and bone in the UTE image is accomplished via a deep learning network that was pre-trained with T1-weighted MR images. UTE images are used as input to the network, which was trained using labels derived from co-registered CT images. The tissue labels estimated by deep learning are refined by a conditional random field based correction. The soft tissue labels are further separated into fat and water components using the two-point Dixon method. The estimated bone, air, fat, and water images are then assigned appropriate Hounsfield units, resulting in a pseudo CT image for PET attenuation correction. To evaluate the proposed MRAC method, PET/MR imaging of the head was performed on 8 human subjects, where Dice similarity coefficients of the estimated tissue labels and relative PET errors were evaluated through comparison to a registered CT image. Dice coefficients for air (within the head), soft tissue, and bone labels were 0.76±0.03, 0.96±0.006, and 0.88±0.01. In PET quantification, the proposed MRAC method produced relative PET errors less than 1% within most brain regions. The proposed MRAC method utilizing deep learning with transfer learning and an efficient dRHE acquisition enables reliable PET quantification with accurate and rapid pseudo CT generation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
٠ا ÙØ§Ø±Ø³Û ØµØØ¨Øª Ù Û Ú©ÙÛÙ ! (We Speak Farsi)
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
æ¥æ¬èªã§ã大ä¸å¤«ã§ãï¼(We Speak Japanese)
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
ÐÑ Ð³Ð¾Ð²Ð¾Ñим по-ÑÑÑÑки! (We Speak Russian)
; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure :00PM Pacific Time, Mon-Fri A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A-Z Index Health &
Targeting MT1-MMP as an ImmunoPET-Based Strategy for Imaging Gliomas
Oteo, M.; Romero, E.; Cámara, J. A.; de Martino, A.; Arroyo, A. G.; Morcillo, M. Á.; Squatrito, M.; Martinez-Torrecuadrada, J. L.; Mulero, F.
2016-01-01
Background A critical challenge in the management of Glioblastoma Multiforme (GBM) tumors is the accurate diagnosis and assessment of tumor progression in a noninvasive manner. We have identified Membrane-type 1 matrix metalloproteinase (MT1-MMP) as an attractive biomarker for GBM imaging since this protein is actively involved in tumor growth and progression, correlates with tumor grade and is closely associated with poor prognosis in GBM patients. Here, we report the development of an immunoPET tracer for effective detection of MT1-MMP in GBM models. Methods An anti-human MT1-MMP monoclonal antibody (mAb), LEM2/15, was conjugated to p-isothiocyanatobenzyl-desferrioxamine (DFO-NCS) for 89Zr labeling. Biodistribution and PET imaging studies were performed in xenograft mice bearing human GBM cells (U251) expressing MT1-MMP and non-expressing breast carcinoma cells (MCF-7) as negative control. Two orthotopic brain GBM models, patient-derived neurospheres (TS543) and U251 cells, with different degrees of blood-brain barrier (BBB) disruption were also used for PET imaging experiments. Results 89Zr labeling of DFO-LEM2/15 was achieved with high yield (>90%) and specific activity (78.5 MBq/mg). Biodistribution experiments indicated that 89Zr-DFO-LEM2/15 showed excellent potential as a radiotracer for detection of MT1-MMP positive GBM tumors. PET imaging also indicated a specific and prominent 89Zr-DFO-LEM2/15 uptake in MT1-MMP+ U251 GBM tumors compared to MT1-MMP- MCF-7 breast tumors. Results obtained in orthotopic brain GBM models revealed a high dependence of a disrupted BBB for tracer penetrance into tumors. 89Zr-DFO-LEM2/15 showed much higher accumulation in TS543 tumors with a highly disrupted BBB than in U251 orthotopic model in which the BBB permeability was only partially increased. Histological analysis confirmed the specificity of the immunoconjugate in all GBM models. Conclusion A new anti MT1-MMP-mAb tracer, 89Zr-DFO-LEM2/15, was synthesized efficiently. In vivo validation showed high-specific-contrast imaging of MT1-MMP positive GBM tumors and provided strong evidence for utility of MT1-MMP-targeted immunoPET as an alternate to nonspecific imaging of GBM. PMID:27462980
High performance ZnO:Al films deposited on PET substrates using facing target sputtering
NASA Astrophysics Data System (ADS)
Guo, Tingting; Dong, Guobo; Gao, Fangyuan; Xiao, Yu; Chen, Qiang; Diao, Xungang
2013-10-01
ZnO:Al (ZAO) thin films have been deposited on flexible PET substrates using a plasma damage-free facing target sputtering system at room temperature. The structure, surface morphology, electrical and optical properties were investigated as a function of working power. All the samples have a highly preferred orientation of the c-axis perpendicular to the PET substrate and have a high quality surface. With increased working power, the carrier concentration changes slightly, the mobility increases at the beginning and decreases after it reaches a maximum value, in line with electrical conductivity. The figure of merit has been significantly improved with increasing of the working power. Under the optimized condition, the lowest resistivity of 1.3 × 10-3 Ω cm with a sheet resistance of 29 Ω/□ and the relative visible transmittance above 93% in the visible region were obtained.
NASA Astrophysics Data System (ADS)
Shidahara, M.; Tsoumpas, C.; McGinnity, C. J.; Kato, T.; Tamura, H.; Hammers, A.; Watabe, H.; Turkheimer, F. E.
2012-05-01
The objective of this study was to evaluate a resolution recovery (RR) method using a variety of simulated human brain [11C]raclopride positron emission tomography (PET) images. Simulated datasets of 15 numerical human phantoms were processed by a wavelet-based RR method using an anatomical prior. The anatomical prior was in the form of a hybrid segmented atlas, which combined an atlas for anatomical labelling and a PET image for functional labelling of each anatomical structure. We applied RR to both 60 min static and dynamic PET images. Recovery was quantified in 84 regions, comparing the typical ‘true’ value for the simulation, as obtained in normal subjects, simulated and RR PET images. The radioactivity concentration in the white matter, striatum and other cortical regions was successfully recovered for the 60 min static image of all 15 human phantoms; the dependence of the solution on accurate anatomical information was demonstrated by the difficulty of the technique to retrieve the subthalamic nuclei due to mismatch between the two atlases used for data simulation and recovery. Structural and functional synergy for resolution recovery (SFS-RR) improved quantification in the caudate and putamen, the main regions of interest, from -30.1% and -26.2% to -17.6% and -15.1%, respectively, for the 60 min static image and from -51.4% and -38.3% to -27.6% and -20.3% for the binding potential (BPND) image, respectively. The proposed methodology proved effective in the RR of small structures from brain [11C]raclopride PET images. The improvement is consistent across the anatomical variability of a simulated population as long as accurate anatomical segmentations are provided.
Caglar, M; Kupik, O; Karabulut, E; Høilund-Carlsen, P F
2016-01-01
To examine the value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for the detection of bone metastasis in breast cancer patients and assess whether whole body bone scan (BS) with (99m)Tc-methylene diphosphonate provides any additional information. Study group comprised 150 patients, mean age 52 years (range 27-85) with breast cancer, suspected of having bone metastases. All patients had undergone both FDG-PET/CT and BS with or without single photon emission tomography/computed tomography (SPECT/CT) within a period of 6 weeks. The final diagnosis of bone metastasis was established by histopathological findings, additional imaging, or clinical follow-up longer than 10 months. Cancer antigen 15-3 (CA15-3) and carcinoembryogenic antigen (CEA) were measured in all patients. Histologically 83%, 7% and 10% had infiltrating ductal, lobular and mixed carcinoma respectively. Confirmed bone metastases were present in 86 patients (57.3%) and absent in 64 (42.7%). Mean CA15-3 and CEA values in patients with bone metastases were 74.6ng/mL and 60.4U/mL respectively, compared to 21.3ng/mL and 3.2U/mL without metastases (p<0.001). The sensitivity of FDG-PET/CT for the detection of bone metastases was 97.6% compared to 89.5% with SPECT/CT. In 57 patients, FDG-PET/CT correctly identified additional pulmonary, hepatic, nodal and other soft tissue metastases, not detected by BS. Our findings suggest that FDG-PET/CT is superior to BS with or without SPECT/CT. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
Nitrous oxide as an indicator of nitrogen transformation in a septic system plume
NASA Astrophysics Data System (ADS)
Li, L.; Spoelstra, J.; Robertson, W. D.; Schiff, S. L.; Elgood, R. J.
2014-11-01
This study evaluates the use of ground water N2O concentration and stable isotope composition for providing insights into nitrogen cycling processes in a large septic system plume in southern Ontario, Canada. An extremely large range of dissolved N2O concentrations were measured (0.4-1071 μg N/L) that were higher than atmospheric equilibrium values of ∼0.3 μg N/L, demonstrating substantial N2O production in the subsurface. The highest N2O concentrations occurred around the periphery of a mid-depth zone where NO3- attenuation, elevated DOC concentration, and NO3- stable isotope ratios provided evidence that denitrification was occurring. Broad ranges in δ15N-N2O (-45.8‰ to +30.6‰) and δ18O-N2O (+20.4‰ to +96.0‰) were evident. Using literature isotopic enrichment factors, which differ for N2O produced during nitrification and denitrification, and measured ranges of plume NH4+ and NO3- isotopic ratios, zones of both nitrifier-derived N2O (shallow zone) and denitrifier-N2O (mid-depth and deeper zones) could be identified. Time series sampling showed that nitrifier N2O was present early in the summer season (June) but then denitrifier N2O was more dominant later in the season. In a mid-depth NO3- depleted zone, the production of denitrifier-N2O was evident early in the season when 15N and 18O enrichment of NO3- was not sufficiently advanced to be indicative of denitrification, although δ15N and δ18O values of NO3- increased later in the season. The analysis of N2O concentrations and stable isotopic composition, in conjunction with conventional chemical analyses, provides insights into N-cycling processes in the Long Point ground water septic plume. However, large ranges in the isotopic composition of N2O produced by nitrifiers and denitrifiers meant that δ15N and δ18O analysis of ground water N2O provided qualitative, rather than quantitative, information on denitrifier versus nitrifier production of N2O at this site.
Defining optimal tracer activities in pediatric oncologic whole-body 18F-FDG-PET/MRI.
Gatidis, Sergios; Schmidt, Holger; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schäfer, Jürgen F
2016-12-01
To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined 18 F-FDG-PET/MRI in pediatric oncology. 30 18 F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV mean and SUV max ) as well as SUV variation (SUV var ) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal 18 F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV mean and SUV max were below 5 % at 18 F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg 18 F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg 18 F-FDG or higher. Administration of 18 F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered 18 F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of 18 F-FDG or other tracers for specific clinical questions have to be further established in selected patient populations.
Functional neuroanatomy of tics.
Neuner, Irene; Schneider, Frank; Shah, N Jon
2013-01-01
The therapeutic success of haloperidol in the treatment of Tourette syndrome (TS) put an end to the discussion about a "hysteric" or "neurotic" origin of TS. The cortico-striato-thalamo-cortical circuit has been identified as an underlying neurobiological correlate of TS. In this review we explore the main findings of structural alterations in TS including cortical areas, basal ganglia, hippocampus, amygdala, midbrain, and cerebellum. Based on the structural changes we examine the functional pattern described by the findings of fMRI and (15)O-PET/(18)FDG PET investigations. From the neuroimaging findings a cortical origin of the generation of tics is indicated. Future research on the neuronal footprint of TS should be directed towards addressing the question of which patterns of connectivity distinguish individuals in whom tics disappear during early adulthood from those in whom the tics persist. The understanding of this pathomechanism could provide a key on how to influence dysconnectivity in TS, for example, by more specific pharmaceutical intervention or by individually adopted EEG and/or fMRI neurofeedback. © 2013 Elsevier Inc. All rights reserved.
da Silva, Dirceu R; Figueiredo, Ana E; Antonello, Ivan C; Poli de Figueiredo, Carlos E; d'Avila, Domingos O
2008-01-01
Differences in small solutes transport rate (SSTR) during peritoneal dialysis (PD) may affect water and solutes removal. Patients with high SSTR must rely on shorter dwell times and increased dialysate glucose concentrations to keep fluid balance. Glucose absorption during peritoneal dialysis (PD), besides affecting glucose and insulin metabolism, may induce weight gain. The study aimed at examining acute glucose and insulin serum level changes and other potential relationships in PD patients with diverse SSTR. This cross-sectional study used a modified peritoneal equilibration test (PET) that enrolled 34 prevalent PD patients. Zero, 15, 30, 60, 120, 180, and 240-minute glucose and insulin serum levels were measured. Insulin resistance index was assessed by the homeostasis model assessment (HOMA-IR) formula. SSTR categories were classified by quartiles of the four-hour dialysate/serum creatinine ratio (D(4)/P(Cr)). Demographic and clinical variables were evaluated, and the body mass index (BMI) was estimated. Correlations among variables of interest and categories of SSTR were explored. Glucose serum levels were significantly different at 15, 30, and 60 minutes between high and low SSTR categories (p = 0.014, 0.009, and 0.022). Increased BMI (25.5 +/- 5.1) and insulin resistance [HOMA-IR = 2.60 (1.40-4.23)] were evidenced overall. Very strong to moderate correlations between insulin levels along the PET and HOMA-IR (r = 0.973, 0.834, 0.766, 0.728, 0.843, 0.857, 0.882) and BMI (r = 0.562, 0.459, 0.417, 0.370, 0.508, 0.514, 0.483) were disclosed. CONCLUSIONS; Early glucose serum levels were associated with SSTR during a PET. Overweight or obesity and insulin resistance were prevalent. An association between insulin serum levels and BMI was demonstrated.
Wang, Liqin; Qi, Yuchun; Dong, Yunshe; Peng, Qin; Guo, Shufang; He, Yunlong; Li, Zhaolin
2017-06-01
High nitrous oxide (N 2 O) emissions during freeze-thawing period (FTP) have been observed in many different ecosystems. However, the knowledge about the dynamic of soil N 2 O emissions and its main driving mechanism during the freeze-thawing processes in grassland ecosystem is still limited. An in-situ experiment was conducted during the FTP on the sites with 0 and 15% surplus of the average rainfall and two levels of N addition (0,10gN/(m 2 ·year)) during growing season (marked as W0N0, W15N0, W0N10, W15N10, respectively) to explore the effects of water and N background on soil N 2 O emissions during FTPs and the relationship between soil N 2 O emissions and environmental factors. The results indicated that water and N treatments conducted during growing season did not show significant effect on the N 2 O effluxes of FTP, but the soil mineral N contents of W0N10 treatment were significantly higher than those of W0N0, W15N0, W15N10 treatments (p<0.05). The soil PLFA concentrations of microbial groups monitored during 2015 spring freeze-thawing period (2015S-FTP) were lower than those during winter freeze-thawing period of 2014 (2014W-FTP), while cumulative soil N 2 O emissions of 2015S-FTP were higher than those of 2014W-FTP. The correlations between soil N 2 O effluxes and most of the measured environmental factors were insignificant, multiple stepwise regression analysis indicated that the soil temperature, soil NH 4 + -N content and air temperature were the major environmental factors which significantly influenced the N 2 O effluxes during 2014W-FTP, and air temperature and soil water content were the significant influencing factors during 2015S-FTP. Copyright © 2016. Published by Elsevier B.V.
Sun, Bai; Zhang, Xuejiao; Zhou, Guangdong; Yu, Tian; Mao, Shuangsuo; Zhu, Shouhui; Zhao, Yong; Xia, Yudong
2018-06-15
In this work, a flexible resistive switching memory device based on ZnO film was fabricated using a foldable Polyethylene terephthalate (PET) film as substrate while Ag and Ti acts top and bottom electrode. Our as-prepared device represents an outstanding nonvolatile memory behavior with good "write-read-erase-read" stability at room temperature. Finally, a physical model of Ag conductive filament is constructed to understanding the observed memory characteristics. The work provides a new way for the preparation of flexible memory devices based on ZnO films, and especially provides an experimental basis for the exploration of high-performance and portable nonvolatile resistance random memory (RRAM). Copyright © 2018 Elsevier Inc. All rights reserved.
Partial Molar Volumes of 15-Crown-5 Ether in Mixtures of N,N-Dimethylformamide with Water.
Tyczyńska, Magdalena; Jóźwiak, Małgorzata
2014-01-01
The density of 15-crown-5 ether (15C5) solutions in the mixtures of N,N -dimethylformamide (DMF) and water (H 2 O) was measured within the temperature range 293.15-308.15 K using an Anton Paar oscillatory U-tube densimeter. The results were used to calculate the apparent molar volumes ( V Φ ) of 15C5 in the mixtures of DMF + H 2 O over the whole concentration range. Using the apparent molar volumes and Redlich and Mayer equation, the standard partial molar volumes of 15-crown-5 were calculated at infinite dilution ([Formula: see text]). The limiting apparent molar expansibilities ( α ) were also calculated. The data are discussed from the point of view of the effect of concentration changes on interactions in solution.
NASA Astrophysics Data System (ADS)
McDougald, Wendy A.; Collins, Richard; Green, Mark; Tavares, Adriana A. S.
2017-10-01
Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT) imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1) to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2) to evaluate the absorbed dose associated with varying CT parameters. Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA) software implemented by Mediso. Measured Hounsfield Unit (HU) in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC), uniformity and quantitative bias were also measured. Results: Only less than 2% and 1% of CT acquisition protocols yielded water HU values < -80 and air HU values < -840, respectively. Four out of eleven CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration. Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed towards improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.
Tukur, Aminu; Sharp, Liz; Stern, Ben; Tizaoui, Chedly; Benkreira, Hadj
2012-04-01
While antimony has been reported to migrate from PET bottles into contents, reports on bottled water and soft drinks usage and PET bottle reuse patterns are currently unavailable in the literature. Bottle use conditions and patterns are important determinants of antimony migration. In this work a survey assessing the pattern of bottle use and reuse in Britain and Nigeria was undertaken. The survey findings influenced the design of laboratory experiments that assessed the migration of antimony from PET bottles into water and soft drinks. Typical storage durations for bottled contents between purchase and opening for use were 7 days or less. However storage of up to one year was reported. Bottle reuse was high and similar for the two countries with reuse durations being higher in Nigeria. The antimony concentration in 32 PET bottle materials from Britain and Nigeria were similar and ranged between 177 and 310 mg kg(-1). For 47 freshly purchased British bottled contents antimony concentration ranged between 0.03 and 6.61 μg L(-1) with only one sample exceeding the EU acceptable limit. Concentrations of Cd, Ge, Zn, Al, Be, Ti, Co and Pb were also measured. At realistic temperatures of 40 and 60 °C antimony concentration in deionised water in bottles remained below the EU acceptable limit even after 48 h exposure. The limit was exceeded for most exposures at 80 °C. Concentration of antimony in some bottled contents exceeded the EU limit after 11 months of storage at room temperature. Bottle aging and increase in bottle volume were associated with decreased migration of antimony from bottles.
Tek Chand, Kalawat; Chennu, Krishna Kishore; Amancharla Yadagiri, Lakshmi; Manthri Gupta, Ranadheer; Rapur, Ram; Vishnubotla, Siva Kumar
2017-04-01
Studies on fever of unknown origin (FUO) in patients of chronic kidney disease and end stage renal disease patients on dialysis were not many. In this study, we used 18 F-FDG PET/CT scan whole body survey for detection of hidden infection, in patients on dialysis, labelled as FUO. In this retrospective study, 20 patients of end stage renal disease on dialysis were investigated for the cause of FUO using 18F-FDG PET/CT scan. All these patients satisfied the definition of FUO as defined by Petersdorf and Beeson. Any focal abnormal site of increased FDG concentration detected by PET/CT, either a solitary or multiple lesions was documented and at least one of the detected abnormal sites of radio tracer concentration was further examined for histopathology. All patients were on renal replacement therapy. Of these, 18 were on hemodialysis and two were on peritoneal dialysis. 18F-FDG PET/CT scan showed metabolically active lesions in 15 patients and metabolically quiescent in five patients. After 18F-FDG PET/CT scan all, but one patient had a change in treatment for fever. Anti-tuberculous treatment was given in 15 patients, antibiotics in four patients and anti-malaria treatment in one patient. The present study is first study of 18F-FDG PET/CT scan in patients of end stage renal disease on dialysis with FUO. The study showed that the 18 F FDG PET/CT scan may present an opportunity to attain the diagnosis in end stage renal disease patients on dialysis with FUO. © 2016 International Society for Hemodialysis.
Hardiansyah, Deni; Attarwala, Ali Asgar; Kletting, Peter; Mottaghy, Felix M; Glatting, Gerhard
2017-10-01
To investigate the accuracy of predicted time-integrated activity coefficients (TIACs) in peptide-receptor radionuclide therapy (PRRT) using simulated dynamic PET data and a physiologically based pharmacokinetic (PBPK) model. PBPK parameters were estimated using biokinetic data of 15 patients after injection of (152±15)MBq of 111 In-DTPAOC (total peptide amount (5.78±0.25)nmol). True mathematical phantoms of patients (MPPs) were the PBPK model with the estimated parameters. Dynamic PET measurements were simulated as being done after bolus injection of 150MBq 68 Ga-DOTATATE using the true MPPs. Dynamic PET scans around 35min p.i. (P 1 ), 4h p.i. (P 2 ) and the combination of P 1 and P 2 (P 3 ) were simulated. Each measurement was simulated with four frames of 5min each and 2 bed positions. PBPK parameters were fitted to the PET data to derive the PET-predicted MPPs. Therapy was simulated assuming an infusion of 5.1GBq of 90 Y-DOTATATE over 30min in both true and PET-predicted MPPs. TIACs of simulated therapy were calculated, true MPPs (true TIACs) and predicted MPPs (predicted TIACs) followed by the calculation of variabilities v. For P 1 and P 2 the population variabilities of kidneys, liver and spleen were acceptable (v<10%). For the tumours and the remainders, the values were large (up to 25%). For P 3 , population variabilities for all organs including the remainder further improved, except that of the tumour (v>10%). Treatment planning of PRRT based on dynamic PET data seems possible for the kidneys, liver and spleen using a PBPK model and patient specific information. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Yang, Shui-Ping; Zhao, Wei; Hu, Pei-Pei; Wu, Ke-Yang; Jiang, Zhi-Hong; Bai, Li-Ping; Li, Min-Min; Chen, Jin-Xiang
2017-12-18
Reactions of La(NO 3 ) 3 ·6H 2 O with the polar, tritopic quaternized carboxylate ligands N-carboxymethyl-3,5-dicarboxylpyridinium bromide (H 3 CmdcpBr) and N-(4-carboxybenzyl)-3,5-dicarboxylpyridinium bromide (H 3 CbdcpBr) afford two water-stable metal-organic frameworks (MOFs) of {[La 4 (Cmdcp) 6 (H 2 O) 9 ]} n (1, 3D) and {[La 2 (Cbdcp) 3 (H 2 O) 10 ]} n (2, 2D). MOFs 1 and 2 absorb the carboxyfluorescein (FAM)-tagged probe DNA (P-DNA) and quench the fluorescence of FAM via a photoinduced electron transfer (PET) process. The nonemissive P-DNA@MOF hybrids thus formed in turn function as sensing platforms to distinguish conservative linear, single-stranded RNA sequences of Sudan virus with high selectivity and low detection limits of 112 and 67 pM, respectively (at a signal-to-noise ratio of 3). These hybrids also exhibit high specificity and discriminate down to single-base mismatch RNA sequences.
The Role of Seven-Coordination in Ru-Catalyzed Water Oxidation
Matheu, Roc; Ertem, Mehmed Z.; Pipelier, Muriel; ...
2018-01-19
A family of Ru complexes based on the pentadentate ligand t5a 3– ((2,5-bis(6-carboxylatopyridin-2-yl)pyrrol-1-ide) and pyridine (py) that includes {Ru II(Ht5a-κ-N 2O)(py) 3} (1H II(κ-N 2O)), {Ru III(t5a-κ-N 3O 1.5)(py) 2} (2 III(κ-N 3O 1.5)), and {Ru IV(t5a-κ-N 3O 2)(py) 2}+ ({2 IV(κ-N3O 2)}+) has been prepared and thoroughly characterized. Complexes 1HII(κ-N 2O), 2 III(κ-N 3O 1.5), and {2 IV(κ-N 3O 2)}+ have been investigated in solution by spectroscopic methods (NMR, UV–vis) and in the solid state by single-crystal X-ray diffraction analysis and complemented by density functional theory (DFT) calculations. The redox properties of complex 2 III(κ-N 3O 1.5) have beenmore » studied by electrochemical methods (CV and DPV), showing its easy access to high oxidation states, thanks to the trianionic nature of the t5a 3– ligand. Under neutral to basic conditions complex {2 IV(κ-N3O 2)}+ undergoes aquation, generating {Ru IV(OH)(t5a-κ-N 2O)(py) 2} (2 IV(OH)(κ-N 2O)). Further oxidation of the complex forms {Ru V(O)(t5a-κ-N 2O)(py) 2} (2 V(O)(κ-N 2O)), which is a very efficient water oxidation catalyst, reaching a TOF MAX value of 9400 s –1 at pH 7.0, as measured via foot of the wave analysis. The key to fast kinetics for the catalytic oxidation of water to dioxygen by 2 V(O)(κ-N 2O) is due not only to the easy access to high oxidation states but also to the intramolecular hydrogen bonding provided by the noncoordinated dangling carboxylate at the transition state, as corroborated by DFT calculations.« less
The Role of Seven-Coordination in Ru-Catalyzed Water Oxidation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matheu, Roc; Ertem, Mehmed Z.; Pipelier, Muriel
A family of Ru complexes based on the pentadentate ligand t5a 3– ((2,5-bis(6-carboxylatopyridin-2-yl)pyrrol-1-ide) and pyridine (py) that includes {Ru II(Ht5a-κ-N 2O)(py) 3} (1H II(κ-N 2O)), {Ru III(t5a-κ-N 3O 1.5)(py) 2} (2 III(κ-N 3O 1.5)), and {Ru IV(t5a-κ-N 3O 2)(py) 2}+ ({2 IV(κ-N3O 2)}+) has been prepared and thoroughly characterized. Complexes 1HII(κ-N 2O), 2 III(κ-N 3O 1.5), and {2 IV(κ-N 3O 2)}+ have been investigated in solution by spectroscopic methods (NMR, UV–vis) and in the solid state by single-crystal X-ray diffraction analysis and complemented by density functional theory (DFT) calculations. The redox properties of complex 2 III(κ-N 3O 1.5) have beenmore » studied by electrochemical methods (CV and DPV), showing its easy access to high oxidation states, thanks to the trianionic nature of the t5a 3– ligand. Under neutral to basic conditions complex {2 IV(κ-N3O 2)}+ undergoes aquation, generating {Ru IV(OH)(t5a-κ-N 2O)(py) 2} (2 IV(OH)(κ-N 2O)). Further oxidation of the complex forms {Ru V(O)(t5a-κ-N 2O)(py) 2} (2 V(O)(κ-N 2O)), which is a very efficient water oxidation catalyst, reaching a TOF MAX value of 9400 s –1 at pH 7.0, as measured via foot of the wave analysis. The key to fast kinetics for the catalytic oxidation of water to dioxygen by 2 V(O)(κ-N 2O) is due not only to the easy access to high oxidation states but also to the intramolecular hydrogen bonding provided by the noncoordinated dangling carboxylate at the transition state, as corroborated by DFT calculations.« less
Water Vapor in the Middle Atmosphere of Venus from the Data of the Venera-15 IR Fourier Spectrometer
NASA Astrophysics Data System (ADS)
Ignat'ev, N. I.; Moroz, V. I.; Zasova, L. V.; Khatuntsev, I. V.
In 1983, the Fourier spectrometer experiment onboard Venera-15 returned spectra of IR radiation (6-50 micron) of the Venusian atmosphere which contained information about temperature, aerosols, and minor constituents, including water vapor. The currently available techniques of radiation-transfer modeling and the H2O-abundance reconstruction allowed us to reanalyze these data, and the most recent results of this analysis are presented here. Most of the measurements are in the range 5-15 ppm. Temporal and spatial variations of the water-vapor abundance were measured. The estimates of H2O abundance calculated from the spectra refer to a certain altitude approximately determined by the level where the optical depth tau in the aerosol continuum near the H2O bands region is close to unity. This altitude varies from 62.5 +/- 2 km at low latitudes to 56 +/- 2 km at high altitudes, but the mean measured water-vapor abundance is found to be roughly the same for both areas, about 10 ppm. At low and middle latitudes, the H2O mixing ratio is maximum on the dayside of the planet and minimum on the nightside. Although the direct reconstruction of the H2O vertical profile from the spectra failed, its indirect estimates confirming the decrease of the mixing ratio with altitude were obtained.
Lithium-Air Battery: Study of Rechargeability and Scalability
2012-07-01
nanowires: MnO2 nanowires were prepared by hydrothermal method. In a typical procedure, an aqueous solution of KMnO4 (0.5 g KMnO4 in 60 ml DD water) was...reduction and oxygen evolution in Li-O2 cell. It was prepared by precipitation method, in which cerium source precipitated as cerium oxalate and...subsequent calcinations yield CeO2 nanoparticles. In a typical procedure, 0.15 M cerous nitrate solution was added drop wise to 1.5 M ammonium oxalate
NASA Astrophysics Data System (ADS)
Frost, Ray L.; Xi, Yunfei
2012-08-01
Nekoite Ca3Si6O15·7H2O and okenite Ca10Si18O46·18H2O are both hydrated calcium silicates found respectively in contact metamorphosed limestone and in association with zeolites from the alteration of basalts. The minerals form two-dimensional infinite sheets with other than six-membered rings with 3-, 4-, or 5-membered rings and 8-membered rings. The two minerals have been characterised by Raman, near-infrared and infrared spectroscopy. The Raman spectrum of nekoite is characterised by two sharp peaks at 1061 and 1092 cm-1 with bands of lesser intensity at 974, 994, 1023 and 1132 cm-1. The Raman spectrum of okenite shows an intense single Raman band at 1090 cm-1 with a shoulder band at 1075 cm-1. These bands are assigned to the SiO stretching vibrations of Si2O5 units. Raman water stretching bands of nekoite are observed at 3071, 3380, 3502 and 3567 cm-1. Raman spectrum of okenite shows water stretching bands at 3029, 3284, 3417, 3531 and 3607 cm-1. NIR spectra of the two minerals are subtly different inferring water with different hydrogen bond strengths. By using a Libowitzky empirical formula, hydrogen bond distances based upon these OH stretching vibrations. Two types of hydrogen bonds are distinguished: strong hydrogen bonds associated with structural water and weaker hydrogen bonds assigned to space filling water molecules.
Sreethawong, Thammanoon; Ngamsinlapasathian, Supachai; Yoshikawa, Susumu
2014-05-01
This work focused on the improvement of the photocatalytic activity for Congo Red (CR) azo dye degradation of mesoporous-assembled 0.95 TiO2-0.05 In2O3 mixed oxide photocatalyst (with a TiO2-to-In2O3 molar ratio of 0.95:0.05) by loading with Ag nanoparticles. The mesoporous-assembled 0.95TiO2-0.05In2O3 mixed oxide photocatalyst was synthesized by a hydrolytic sol-gel method with the aid of a structure-directing surfactant, prior to loading with various Ag contents (0.5-2 wt.%) by a photochemical deposition method. The optimum Ag loading content was found to be 1.5 wt.%, exhibiting a great increase in photocatalytic CR dye degradation activity. The 1.5 wt.% Ag-loaded 0.95TiO2-0.05In2O3 mixed oxide photocatalyst was further applied for the CR dye degradation in the presence of water hardness. Different types (Ca2+ and Ca2+ -Mg2+ mixture) and concentrations (200 and 500 mg/l) of water hardness were investigated. The results showed that the water hardness reduced the photocatalytic CR dye degradation activity, particularly for the extremely hard water with 500 mg/l of Ca2+ -Mg2+ mixture. The adjustment of initial solution pH of the CR dye-containing hard water to an appropriate value was found to improve the photocatalytic CR dye degradation activity under the identical reaction conditions. Copyright © 2014 Elsevier Inc. All rights reserved.
2011-04-14
'. . . ( r · c. t. • , r C. r ~ , ,. ~ l .. .. t • , . .. t' ' c.: . ~. t' ,-' , e ('\\ r ,-' .. I > t ' .... o~ ... ~ c: • , cr.. • • t' • • r t • · , t I, >, • t I. · \\ ( o c o • , ' . o ...
Structural insight into molecular mechanism of poly(ethylene terephthalate) degradation.
Joo, Seongjoon; Cho, In Jin; Seo, Hogyun; Son, Hyeoncheol Francis; Sagong, Hye-Young; Shin, Tae Joo; Choi, So Young; Lee, Sang Yup; Kim, Kyung-Jin
2018-01-26
Plastics, including poly(ethylene terephthalate) (PET), possess many desirable characteristics and thus are widely used in daily life. However, non-biodegradability, once thought to be an advantage offered by plastics, is causing major environmental problem. Recently, a PET-degrading bacterium, Ideonella sakaiensis, was identified and suggested for possible use in degradation and/or recycling of PET. However, the molecular mechanism of PET degradation is not known. Here we report the crystal structure of I. sakaiensis PETase (IsPETase) at 1.5 Å resolution. IsPETase has a Ser-His-Asp catalytic triad at its active site and contains an optimal substrate binding site to accommodate four monohydroxyethyl terephthalate (MHET) moieties of PET. Based on structural and site-directed mutagenesis experiments, the detailed process of PET degradation into MHET, terephthalic acid, and ethylene glycol is suggested. Moreover, other PETase candidates potentially having high PET-degrading activities are suggested based on phylogenetic tree analysis of 69 PETase-like proteins.
Year-round N2O production by benthic NOx reduction in a monomictic south-alpine lake
NASA Astrophysics Data System (ADS)
Freymond, C. V.; Wenk, C. B.; Frame, C. H.; Lehmann, M. F.
2013-12-01
Nitrous oxide (N2O) is a potent greenhouse gas, generated through microbial nitrogen (N) turnover processes, such as nitrification, nitrifier denitrification, and denitrification. Previous studies quantifying natural sources have mainly focused on soils and the ocean, but the potential role of terrestrial water bodies in the global N2O budget has been widely neglected. Furthermore, the biogeochemical controls on the production rates and the microbial pathways that produce benthic N2O in lakes are essentially unknown. In this study, benthic N2O fluxes and the contributions of the microbial pathways that produce N2O were assessed using 15N label flow-through sediment incubations in the eutrophic, monomictic south basin of Lake Lugano in Switzerland. The sediments were a significant source of N2O throughout the year, with production rates ranging between 140 and 2605 nmol N2O h-1 m-2, and the highest observed rates coinciding with periods of water column stratification and stably anoxic conditions in the overlying bottom water. Nitrate (NO3-) reduction via denitrification was found to be the major N2O production pathway in the sediments under both oxygen-depleted and oxygen-replete conditions in the overlying water, while ammonium oxidation did not contribute significantly to the benthic N2O flux. A marked portion (up to 15%) of the total NO3- consumed by denitrification was reduced only to N2O, without complete denitrification to N2. These fluxes were highest when the bottom water had stabilized to a low-oxygen state, in contrast with the notion that stable anoxia is particularly conducive to complete denitrification without accumulation of N2O. This study provides evidence that lake sediments are a significant source of N2O to the overlying water and may produce large N2O fluxes to the atmosphere during seasonal mixing events.
Determination of the δ15N of nitrate in solids; RSIL lab code 2894
Coplen, Tyler B.; Qi, Haiping; Revesz, Kinga; Casciotti, Karen; Hannon, Janet E.
2007-01-01
The purpose of the Reston Stable Isotope Laboratory (RSIL) lab code 2894 is to determine the δ15N of nitrate (NO3-) in solids. The nitrate fraction of the nitrogen species is dissolved by water (called leaching) and can be analyzed by the bacterial method covered in RSIL lab code 2899. After leaching, the δ15N of the dissolved NO3- is analyzed by conversion of the NO3- to nitrous oxide (N2O), which serves as the analyte for mass spectrometry. A culture of denitrifying bacteria is used in the enzymatic conversion of NO3- to N2O, which follows the pathway shown in equation 1: NO3- → NO2- → NO → 1/2 N2O (1) Because the bacteria Pseudomonas aureofaciens lack N2O reductive activity, the reaction stops at N2O, unlike the typical denitrification reaction that goes to N2. After several hours, the conversion is complete, and the N2O is extracted from the vial, separated from volatile organic vapor and water vapor by an automated -65 °C isopropanol-slush trap, a Nafion drier, a CO2 and water removal unit (Costech #021020 carbon dioxide absorbent with Mg(ClO4)2), and trapped in a small-volume trap immersed in liquid nitrogen with a modified Finnigan MAT (now Thermo Scientific) GasBench 2 introduction system. After the N2O is released, it is further purified by gas chromatography before introduction to the isotope-ratio mass spectrometer (IRMS). The IRMS is a Thermo Scientific Delta V Plus continuous flow IRMS (CF-IRMS). It has a universal triple collector, consisting of two wide cups with a narrow cup in the middle; it is capable of simultaneously measuring mass/charge (m/z) of the N2O molecule 44, 45, and 46. The ion beams from these m/z values are as follows: m/z = 44 = N2O = 14N14N16O; m/z = 45 = N2O = 14N15N16O or 14N14N17O; m/z = 46 = N2O = 14N14N18O. The 17O contributions to the m/z 44 and m/z 45 ion beams are accounted for before δ15N values are reported.
Mass spectrometric and theoretical investigation of sulfate clusters in nanoscale water droplets
NASA Astrophysics Data System (ADS)
Lemke, K.
2017-12-01
The solvation of sulfate clusters of varying size and charge in water clusters and in nanoscale water droplets has been studied using electrospray ionization (ESI) FT-MS and density functional theory (DFT) molecular simulations. ESI mass spectra of solvated [Mg(MgSO4)m]2+(H2O)n with m≤10 and up to 15 water molecules have been recorded, and ion cluster experiments have been undertaken using a custom-modified FT-ICR mass spectrometer with the ability of IRMPD for ion dissociation. We present equilibrium geometries and energies for [Mg(MgSO4)m]2+(H2O)n, water-free and solvated with up to 100 water molecules, using swarm-based optimizers and DFT level calculations. Dominant cluster species identified following ESI of dilute (1-5 mM) MgSO4 solutions include hexa- and octa-nuclear magnesium sulfate ions, water-free and with a full first shell of water molecules. The largest clusters identified are magnesium sulfate decamers, i.e. [Mg(MgSO4)10]2+(H2O)n, with n≤15. As a very first step towards understanding the distribution and intensity of ESI ion mass spectra, we have identified the global minima of [Mg(MgSO4)m]2+(H2O)n with m≤10 and n≤100, and located likely global minima of magnesium sulfate clusters in the gas phase and in nano-scale water droplets. We will present a summary of the structural and energetic trends of solvated magnesium sulfate clusters, with a particular focus on structural transitions induced by cluster growth and solvation, the occurrence of "magic" number cluster species, their energetic properties and their potential role as atmospheric aqueous species.
Gulec, Seza A; Daghighian, Farhad; Essner, Richard
2016-12-01
Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions <1 cm, and the intraoperative localization of small PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.
Evaluation of a spatially-distributed Thornthwaite water-balance model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lough, J.A.
1993-03-01
A small watershed of low relief in coastal New Hampshire was divided into hydrologic sub-areas in a geographic information system on the basis of soils, sub-basins and remotely-sensed landcover. Three variables were spatially modeled for input to 49 individual water-balances: available water content of the root zone, water input and potential evapotranspiration (PET). The individual balances were weight-summed to generate the aggregate watershed-balance, which saw 9% (48--50 mm) less annual actual-evapotranspiration (AET) compared to a lumped approach. Analysis of streamflow coefficients suggests that the spatially-distributed approach is more representative of the basin dynamics. Variation of PET by landcover accounted formore » the majority of the 9% AET reduction. Variation of soils played a near-negligible role. As a consequence of the above points, estimates of landcover proportions and annual PET by landcover are sufficient to correct a lumped water-balance in the Northeast. If remote sensing is used to estimate the landcover area, a sensor with a high spatial resolution is required. Finally, while the lower Thornthwaite model has conceptual limitations for distributed application, the upper Thornthwaite model is highly adaptable to distributed problems and may prove useful in many earth-system models.« less