Dark-count-less photon-counting x-ray computed tomography system using a YAP-MPPC detector
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Sato, Yuich; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2012-10-01
A high-sensitive X-ray computed tomography (CT) system is useful for decreasing absorbed dose for patients, and a dark-count-less photon-counting CT system was developed. X-ray photons are detected using a YAP(Ce) [cerium-doped yttrium aluminum perovskite] single crystal scintillator and an MPPC (multipixel photon counter). Photocurrents are amplified by a high-speed current-voltage amplifier, and smooth event pulses from an integrator are sent to a high-speed comparator. Then, logical pulses are produced from the comparator and are counted by a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The image contrast of gadolinium medium slightly fell with increase in lower-level voltage (Vl) of the comparator. The dark count rate was 0 cps, and the count rate for the CT was approximately 250 kcps.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podgorsak, A; Bednarek, D; Rudin, S
2016-06-15
Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence.more » The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.« less
Three-dimensional passive sensing photon counting for object classification
NASA Astrophysics Data System (ADS)
Yeom, Seokwon; Javidi, Bahram; Watson, Edward
2007-04-01
In this keynote address, we address three-dimensional (3D) distortion-tolerant object recognition using photon-counting integral imaging (II). A photon-counting linear discriminant analysis (LDA) is discussed for classification of photon-limited images. We develop a compact distortion-tolerant recognition system based on the multiple-perspective imaging of II. Experimental and simulation results have shown that a low level of photons is sufficient to classify out-of-plane rotated objects.
Sato, Eiichi; Sugimura, Shigeaki; Endo, Haruyuki; Oda, Yasuyuki; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Osawa, Akihiro; Matsukiyo, Hiroshi; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2012-01-01
15Mcps photon-counting X-ray computed tomography (CT) system is a first-generation type and consists of an X-ray generator, a turntable, a translation stage, a two-stage controller, a detector consisting of a 2mm-thick zinc-oxide (ZnO) single-crystal scintillator and an MPPC (multipixel photon counter) module, a counter card (CC), and a personal computer (PC). High-speed photon counting was carried out using the detector in the X-ray CT system. The maximum count rate was 15Mcps (mega counts per second) at a tube voltage of 100kV and a tube current of 1.95mA. Tomography is accomplished by repeated translations and rotations of an object, and projection curves of the object are obtained by the translation. The pulses of the event signal from the module are counted by the CC in conjunction with the PC. The minimum exposure time for obtaining a tomogram was 15min, and photon-counting CT was accomplished using gadolinium-based contrast media. Copyright © 2011 Elsevier Ltd. All rights reserved.
Fazio, B B
1994-04-01
This study examined the counting abilities of preschool children with specific language impairment compared to language-matched and mental-age-matched peers. In order to determine the nature of the difficulties SLI children exhibited in counting, the subjects participated in a series of oral counting tasks and a series of gestural tasks that used an invented counting system based on pointing to body parts. Despite demonstrating knowledge of many of the rules associated with counting, SLI preschool children displayed marked difficulty in counting objects. On oral counting tasks, they showed difficulty with rote counting, displayed a limited repertoire of number terms, and miscounted sets of objects. However, on gestural counting tasks, SLI children's performance was significantly better. These findings suggest that SLI children have a specific difficulty with the rote sequential aspect of learning number words.
Mcps-range photon-counting x-ray computed tomography system
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Oda, Yasuyuki; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Enomoto, Toshiyuki; Sugimura, Shigeaki; Endo, Haruyuki; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-10-01
10 Mcps photon counting was carried out using a detector consisting of a 2.0 mm-thick ZnO (zinc oxide) single-crystal scintillator and an MPPC (multipixel photon counter) module in an X-ray computed tomography (CT) system. The maximum count rate was 10 Mcps (mega counts per second) at a tube voltage of 70 kV and a tube current of 2.0 mA. Next, a photon-counting X-ray CT system consists of an X-ray generator, a turntable, a scan stage, a two-stage controller, the ZnO-MPPC detector, a counter card (CC), and a personal computer (PC). Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan with a scan velocity of 25 mm/s. The pulses of the event signal from the module are counted by the CC in conjunction with the PC. The exposure time for obtaining a tomogram was 600 s at a scan step of 0.5 mm and a rotation step of 1.0°, and photon-counting CT was accomplished using iodine-based contrast media.
NASA Astrophysics Data System (ADS)
Oda, Yasuyuki; Sato, Eiichi; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Osawa, Akihiro; Matsukiyo, Hiroshi; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sugimura, Shigeaki; Endo, Haruyuki; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-07-01
High-speed X-ray photon counting is useful for discriminating photon energy, and the counting can be used for constructing an X-ray computed tomography (CT) system. A photon-counting X-ray CT system consists of an X-ray generator, a turntable, an oscillation linear detector, a two-stage controller, a multipixel photon counter (MPPC) module, a 1.0 mm-thick crystal (scintillator) of YAP(Ce) (cerium-doped yttrium aluminum perovskite), a counter card (CC), and a personal computer (PC). Tomography is accomplished by repeating the linear scanning and the rotation of an object, and projection curves of the object are obtained by the linear scanning using the detector consisting of an MPPC module, the YAP(Ce), and a scan stage. The pulses of the event signal from the module are counted by the CC in conjunction with the PC. Because the lower level of the photon energy was roughly determined by a comparator in the module, the average photon energy of the X-ray spectra increased with increase in the lower-level voltage of the comparator at a constant tube voltage. The maximum count rate was approximately 3 Mcps (mega counts per second), and photon-counting CT was carried out.
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Oda, Yasuyuki; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sugimura, Shigeaki; Endo, Haruyuki; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-12-01
6 Mcps photon counting was carried out using a detector consisting of a 1.0 mm-thick LSO [Lu 2(SiO 4)O] single-crystal scintillator and an MPPC (multipixel photon counter) module in an X-ray computed tomography (CT) system. The maximum count rate was 6 Mcps (mega counts per second) at a tube voltage of 100 kV and a tube current of 0.91 mA. Next, a photon-counting X-ray CT system consists of an X-ray generator, a turntable, a scan stage, a two-stage controller, the LSO-MPPC detector, a counter card (CC), and a personal computer (PC). Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan with a scan velocity of 25 mm/s. The pulses of the event signal from the module are counted by the CC in conjunction with the PC. The exposure time for obtaining a tomogram was 600 s at a scan step of 0.5 mm and a rotation step of 1.0°, and photon-counting CT was accomplished using gadolinium-based contrast media.
Design Study of an Incinerator Ash Conveyor Counting System - 13323
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaederstroem, Henrik; Bronson, Frazier
A design study has been performed for a system that should measure the Cs-137 activity in ash from an incinerator. Radioactive ash, expected to consist of both Cs-134 and Cs-137, will be transported on a conveyor belt at 0.1 m/s. The objective of the counting system is to determine the Cs-137 activity and direct the ash to the correct stream after a diverter. The decision levels are ranging from 8000 to 400000 Bq/kg and the decision error should be as low as possible. The decision error depends on the total measurement uncertainty which depends on the counting statistics and themore » uncertainty in the efficiency of the geometry. For the low activity decision it is necessary to know the efficiency to be able to determine if the signal from the Cs-137 is above the minimum detectable activity and that it generates enough counts to reach the desired precision. For the higher activity decision the uncertainty of the efficiency needs to be understood to minimize decision errors. The total efficiency of the detector is needed to be able to determine if the detector will be able operate at the count rate at the highest expected activity. The design study that is presented in this paper describes how the objectives of the monitoring systems were obtained, the choice of detector was made and how ISOCS (In Situ Object Counting System) mathematical modeling was used to calculate the efficiency. The ISOCS uncertainty estimator (IUE) was used to determine which parameters of the ash was important to know accurately in order to minimize the uncertainty of the efficiency. The examined parameters include the height of the ash on the conveyor belt, the matrix composition and density and relative efficiency of the detector. (authors)« less
A Vision-Based Counting and Recognition System for Flying Insects in Intelligent Agriculture.
Zhong, Yuanhong; Gao, Junyuan; Lei, Qilun; Zhou, Yao
2018-05-09
Rapid and accurate counting and recognition of flying insects are of great importance, especially for pest control. Traditional manual identification and counting of flying insects is labor intensive and inefficient. In this study, a vision-based counting and classification system for flying insects is designed and implemented. The system is constructed as follows: firstly, a yellow sticky trap is installed in the surveillance area to trap flying insects and a camera is set up to collect real-time images. Then the detection and coarse counting method based on You Only Look Once (YOLO) object detection, the classification method and fine counting based on Support Vector Machines (SVM) using global features are designed. Finally, the insect counting and recognition system is implemented on Raspberry PI. Six species of flying insects including bee, fly, mosquito, moth, chafer and fruit fly are selected to assess the effectiveness of the system. Compared with the conventional methods, the test results show promising performance. The average counting accuracy is 92.50% and average classifying accuracy is 90.18% on Raspberry PI. The proposed system is easy-to-use and provides efficient and accurate recognition data, therefore, it can be used for intelligent agriculture applications.
A Vision-Based Counting and Recognition System for Flying Insects in Intelligent Agriculture
Zhong, Yuanhong; Gao, Junyuan; Lei, Qilun; Zhou, Yao
2018-01-01
Rapid and accurate counting and recognition of flying insects are of great importance, especially for pest control. Traditional manual identification and counting of flying insects is labor intensive and inefficient. In this study, a vision-based counting and classification system for flying insects is designed and implemented. The system is constructed as follows: firstly, a yellow sticky trap is installed in the surveillance area to trap flying insects and a camera is set up to collect real-time images. Then the detection and coarse counting method based on You Only Look Once (YOLO) object detection, the classification method and fine counting based on Support Vector Machines (SVM) using global features are designed. Finally, the insect counting and recognition system is implemented on Raspberry PI. Six species of flying insects including bee, fly, mosquito, moth, chafer and fruit fly are selected to assess the effectiveness of the system. Compared with the conventional methods, the test results show promising performance. The average counting accuracy is 92.50% and average classifying accuracy is 90.18% on Raspberry PI. The proposed system is easy-to-use and provides efficient and accurate recognition data, therefore, it can be used for intelligent agriculture applications. PMID:29747429
High-speed photon-counting x-ray computed tomography system utilizing a multipixel photon counter
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Takahashi, Kiyomi; Sato, Shigehiro; Ogawa, Akiro; Onagawa, Jun
2009-07-01
High-speed photon counting is useful for discriminating photon energy and for decreasing absorbed dose for patients in medical radiography, and the counting is usable for constructing an x-ray computed tomography (CT) system. A photon-counting x-ray CT system is of the first generation type and consists of an x-ray generator, a turn table, a translation stage, a two-stage controller, a multipixel photon counter (MPPC) module, a 1.0-mm-thick LSO crystal (scintillator), a counter card (CC), and a personal computer (PC). Tomography is accomplished by repeating the linear scanning and the rotation of an object, and projection curves of the object are obtained by the linear scanning using the detector consisting of a MPPC module and the LSO. The pulses of the event signal from the module are counted by the CC in conjunction with the PC. The lower level of the photon energy is roughly determined by a comparator circuit in the module, and the unit of the level is the photon equivalent (pe). Thus, the average photon energy of the x-ray spectra increases with increasing the lower-level voltage of the comparator. The maximum count rate was approximately 20 Mcps, and energy-discriminated CT was roughly carried out.
A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowman, P.
2016-10-03
Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has beenmore » considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.« less
Advances in photon counting for bioluminescence
NASA Astrophysics Data System (ADS)
Ingle, Martin B.; Powell, Ralph
1998-11-01
Photon counting systems were originally developed for astronomy, initially by the astronomical community. However, a major application area is in the study of luminescent probes in living plants, fishes and cell cultures. For these applications, it has been necessary to develop camera system capability at very low light levels -- a few photons occasionally -- and also at reasonably high light levels to enable the systems to be focused and to collect quality images of the object under study. The paper presents new data on MTF at extremely low photon flux and conventional ICCD illumination, counting efficiency and dark noise as a function of temperature.
Quantifying evenly distributed states in exclusion and nonexclusion processes
NASA Astrophysics Data System (ADS)
Binder, Benjamin J.; Landman, Kerry A.
2011-04-01
Spatial-point data sets, generated from a wide range of physical systems and mathematical models, can be analyzed by counting the number of objects in equally sized bins. We find that the bin counts are related to the Pólya distribution. New measures are developed which indicate whether or not a spatial data set, generated from an exclusion process, is at its most evenly distributed state, the complete spatial randomness (CSR) state. To this end, we define an index in terms of the variance between the bin counts. Limiting values of the index are determined when objects have access to the entire domain and when there are subregions of the domain that are inaccessible to objects. Using three case studies (Lagrangian fluid particles in chaotic laminar flows, cellular automata agents in discrete models, and biological cells within colonies), we calculate the indexes and verify that our theoretical CSR limit accurately predicts the state of the system. These measures should prove useful in many biological applications.
Detecting and Analyzing Multiple Moving Objects in Crowded Environments with Coherent Motion Regions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheriyadat, Anil M.
Understanding the world around us from large-scale video data requires vision systems that can perform automatic interpretation. While human eyes can unconsciously perceive independent objects in crowded scenes and other challenging operating environments, automated systems have difficulty detecting, counting, and understanding their behavior in similar scenes. Computer scientists at ORNL have a developed a technology termed as "Coherent Motion Region Detection" that invloves identifying multiple indepedent moving objects in crowded scenes by aggregating low-level motion cues extracted from moving objects. Humans and other species exploit such low-level motion cues seamlessely to perform perceptual grouping for visual understanding. The algorithm detectsmore » and tracks feature points on moving objects resulting in partial trajectories that span coherent 3D region in the space-time volume defined by the video. In the case of multi-object motion, many possible coherent motion regions can be constructed around the set of trajectories. The unique approach in the algorithm is to identify all possible coherent motion regions, then extract a subset of motion regions based on an innovative measure to automatically locate moving objects in crowded environments.The software reports snapshot of the object, count, and derived statistics ( count over time) from input video streams. The software can directly process videos streamed over the internet or directly from a hardware device (camera).« less
Bender, Andrea; Schlimm, Dirk; Beller, Sieghard
2015-10-01
The domain of numbers provides a paradigmatic case for investigating interactions of culture, language, and cognition: Numerical competencies are considered a core domain of knowledge, and yet the development of specifically human abilities presupposes cultural and linguistic input by way of counting sequences. These sequences constitute systems with distinct structural properties, the cross-linguistic variability of which has implications for number representation and processing. Such representational effects are scrutinized for two types of verbal numeration systems-general and object-specific ones-that were in parallel use in several Oceanic languages (English with its general system is included for comparison). The analysis indicates that the object-specific systems outperform the general systems with respect to counting and mental arithmetic, largely due to their regular and more compact representation. What these findings reveal on cognitive diversity, how the conjectures involved speak to more general issues in cognitive science, and how the approach taken here might help to bridge the gap between anthropology and other cognitive sciences is discussed in the conclusion. Copyright © 2015 Cognitive Science Society, Inc.
Approach for counting vehicles in congested traffic flow
NASA Astrophysics Data System (ADS)
Tan, Xiaojun; Li, Jun; Liu, Wei
2005-02-01
More and more image sensors are used in intelligent transportation systems. In practice, occlusion is always a problem when counting vehicles in congested traffic. This paper tries to present an approach to solve the problem. The proposed approach consists of three main procedures. Firstly, a new algorithm of background subtraction is performed. The aim is to segment moving objects from an illumination-variant background. Secondly, object tracking is performed, where the CONDENSATION algorithm is used. This can avoid the problem of matching vehicles in successive frames. Thirdly, an inspecting procedure is executed to count the vehicles. When a bus firstly occludes a car and then the bus moves away a few frames later, the car will appear in the scene. The inspecting procedure should find the "new" car and add it as a tracking object.
Real-time people counting system using a single video camera
NASA Astrophysics Data System (ADS)
Lefloch, Damien; Cheikh, Faouzi A.; Hardeberg, Jon Y.; Gouton, Pierre; Picot-Clemente, Romain
2008-02-01
There is growing interest in video-based solutions for people monitoring and counting in business and security applications. Compared to classic sensor-based solutions the video-based ones allow for more versatile functionalities, improved performance with lower costs. In this paper, we propose a real-time system for people counting based on single low-end non-calibrated video camera. The two main challenges addressed in this paper are: robust estimation of the scene background and the number of real persons in merge-split scenarios. The latter is likely to occur whenever multiple persons move closely, e.g. in shopping centers. Several persons may be considered to be a single person by automatic segmentation algorithms, due to occlusions or shadows, leading to under-counting. Therefore, to account for noises, illumination and static objects changes, a background substraction is performed using an adaptive background model (updated over time based on motion information) and automatic thresholding. Furthermore, post-processing of the segmentation results is performed, in the HSV color space, to remove shadows. Moving objects are tracked using an adaptive Kalman filter, allowing a robust estimation of the objects future positions even under heavy occlusion. The system is implemented in Matlab, and gives encouraging results even at high frame rates. Experimental results obtained based on the PETS2006 datasets are presented at the end of the paper.
Experimental Study for Automatic Colony Counting System Based Onimage Processing
NASA Astrophysics Data System (ADS)
Fang, Junlong; Li, Wenzhe; Wang, Guoxin
Colony counting in many colony experiments is detected by manual method at present, therefore it is difficult for man to execute the method quickly and accurately .A new automatic colony counting system was developed. Making use of image-processing technology, a study was made on the feasibility of distinguishing objectively white bacterial colonies from clear plates according to the RGB color theory. An optimal chromatic value was obtained based upon a lot of experiments on the distribution of the chromatic value. It has been proved that the method greatly improves the accuracy and efficiency of the colony counting and the counting result is not affected by using inoculation, shape or size of the colony. It is revealed that automatic detection of colony quantity using image-processing technology could be an effective way.
The Robustness of Pre-School Children's Tendency to Count Discrete Physical Objects
ERIC Educational Resources Information Center
Fletcher, Ben; Pine, Karen J.
2009-01-01
When pre-school children count an array of objects containing one that is broken in half, most count the halves as two separate objects. Two studies explore this predisposition to count discrete physical objects (DPOs) and investigate its robustness in the face of various manipulations. In Experiment 1, 32 children aged three-four years counted…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-24
.... The six counted objects are one core, two unidentified ground stone items, one iron container, and two... funerary objects are one counted object and seven lots of objects, which are one piece of modified bone... identified. The seven associated funerary objects are one counted object and six lots of objects, which are...
USDA-ARS?s Scientific Manuscript database
Pubertal heifers can be classified between those with high (= 25) and low (= 15) antral follicle counts (AFC). The objective of this study was to determine oocyte development and maturation (e.g., fertility) in an in vitro fertilization (IVF) system for high and low AFC heifers. From a pool of 120...
NASA Astrophysics Data System (ADS)
Hagiwara, Osahiko; Watanabe, Manabu; Sato, Eiichi; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-05-01
Demonstration of narrow-energy-width computed tomography (CT) was carried out by means of energy-discrimination. An X-ray CT system is of a first-generation type and consists of an X-ray generator, a turntable, a translation stage, a two-stage controller, a silicon-PIN detector system with amplifiers, a multi-channel analyzer (MCA), a counter card (CC), and a personal computer (PC). CT is accomplished by repeating the translation and the rotation of an object, and projection curves of the object are obtained by the translation of the moving object. Both photon-energy level and energy width are determined by the MCA, and the pulses of the discriminated event signal from the MCA are counted by CC in conjunction with PC. The maximum count rate was approximately 300 cps (counts per second) with energy widths of 2.0 keV, and energy-discrimination CT was carried out with a photon-energy resolution of 0.15 keV. To perform iodine K-edge CT, X-ray photons with an energy range from 33.2 to 35.2 keV were used. Next, to carry out cerium K-edge CT, an energy range from 40.3 to 42.3 keV was selected.
Reduction of Energy Intake using Just-In-Time Feedback from a Wearable Sensor System
Farooq, Muhammad; McCrory, Megan A.; Sazonov, Edward
2017-01-01
Objective This work explored the potential use of a wearable sensor system for providing just-in-time (JIT) feedback on the progression of a meal and tested its ability to reduce the total food mass intake. Methods Eighteen participants each consumed three meals in a lab while monitored by a wearable sensor system capable of accurately tracking chew counts. The baseline visit was used to establish the self-determined ingested mass and the associated chew counts. Real-time feedback on chew counts was provided in the next two visits during which the target chew counts was either the same as that at baseline or the baseline chew counts reduced by 25%, in randomized order. The target was concealed from the participant and from the experimenter. Nonparametric repeated-measures ANOVA were performed to compare mass of intake, meal duration, and ratings of hunger, appetite, and thirst across 3 meals. Results JIT feedback targeting a 25% reduction in chew counts resulted in a reduction in mass and energy intake without affecting perceived hunger or fullness. Conclusion JIT feedback on chewing behavior may reduce intake within a meal. This system can be further used to help develop individualized strategies to provide just-in-time adaptive interventions for reducing energy intake. PMID:28233942
Protecting count queries in study design
Sarwate, Anand D; Boxwala, Aziz A
2012-01-01
Objective Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. Methods A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Results Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Conclusions Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems. PMID:22511018
Crooks, Michael G; den Brinker, Albertus; Hayman, Yvette; Williamson, James D; Innes, Andrew; Wright, Caroline E; Hill, Peter; Morice, Alyn H
2017-06-01
Cough is common in chronic obstructive pulmonary disease (COPD) and is associated with frequent exacerbations and increased mortality. Cough increases during acute exacerbations (AE-COPD), representing a possible metric of clinical deterioration. Conventional cough monitors accurately report cough counts over short time periods. We describe a novel monitoring system which we used to record cough continuously for up to 45 days during AE-COPD convalescence. This is a longitudinal, observational study of cough monitoring in AE-COPD patients discharged from a single teaching hospital. Ambient sound was recorded from two sites in the domestic environment and analysed using novel cough classifier software. For comparison, the validated hybrid HACC/LCM cough monitoring system was used on days 1, 5, 20 and 45. Patients were asked to record symptoms daily using diaries. Cough monitoring data were available for 16 subjects with a total of 568 monitored days. Daily cough count fell significantly from mean ± SEM 272.7 ± 54.5 on day 1 to 110.9 ± 26.3 on day 9 (p < 0.01) before plateauing. The absolute cough count detected by the continuous monitoring system was significantly lower than detected by the hybrid HACC/LCM system but normalised counts strongly correlated (r = 0.88, p < 0.01) demonstrating an ability to detect trends. Objective cough count and subjective cough scores modestly correlated (r = 0.46). Cough frequency declines significantly following AE-COPD and the reducing trend can be detected using continuous ambient sound recording and novel cough classifier software. Objective measurement of cough frequency has the potential to enhance our ability to monitor the clinical state in patients with COPD.
Development of spatial preferences for counting and picture naming.
Knudsen, Birgit; Fischer, Martin H; Aschersleben, Gisa
2015-11-01
The direction of object enumeration reflects children's enculturation but previous work on the development of such spatial preferences has been inconsistent. Therefore, we documented directional preferences in finger counting, object counting, and picture naming for children (4 groups from 3 to 6 years, N = 104) and adults (N = 56). We found a right-side preference for finger counting in 3- to 6-year-olds and a left-side preference for counting objects and naming pictures by 6 years of age. Children were consistent in their special preferences when comparing object counting and picture naming, but not in other task pairings. Finally, spatial preferences were not related to cardinality comprehension. These results, together with other recent work, suggest a gradual development of spatial-numerical associations from early non-directional mappings into culturally constrained directional mappings.
ERIC Educational Resources Information Center
Petersen, Lori A.; McNeil, Nicole M.
2013-01-01
Educators often use concrete objects to help children understand mathematics concepts. However, findings on the effectiveness of concrete objects are mixed. The present study examined how two factors--perceptual richness and established knowledge of the objects--combine to influence children's counting performance. In two experiments, preschoolers…
Textual and shape-based feature extraction and neuro-fuzzy classifier for nuclear track recognition
NASA Astrophysics Data System (ADS)
Khayat, Omid; Afarideh, Hossein
2013-04-01
Track counting algorithms as one of the fundamental principles of nuclear science have been emphasized in the recent years. Accurate measurement of nuclear tracks on solid-state nuclear track detectors is the aim of track counting systems. Commonly track counting systems comprise a hardware system for the task of imaging and software for analysing the track images. In this paper, a track recognition algorithm based on 12 defined textual and shape-based features and a neuro-fuzzy classifier is proposed. Features are defined so as to discern the tracks from the background and small objects. Then, according to the defined features, tracks are detected using a trained neuro-fuzzy system. Features and the classifier are finally validated via 100 Alpha track images and 40 training samples. It is shown that principle textual and shape-based features concomitantly yield a high rate of track detection compared with the single-feature based methods.
Effective count rates for PET scanners with reduced and extended axial field of view
NASA Astrophysics Data System (ADS)
MacDonald, L. R.; Harrison, R. L.; Alessio, A. M.; Hunter, W. C. J.; Lewellen, T. K.; Kinahan, P. E.
2011-06-01
We investigated the relationship between noise equivalent count (NEC) and axial field of view (AFOV) for PET scanners with AFOVs ranging from one-half to twice those of current clinical scanners. PET scanners with longer or shorter AFOVs could fulfill different clinical needs depending on exam volumes and site economics. Using previously validated Monte Carlo simulations, we modeled true, scattered and random coincidence counting rates for a PET ring diameter of 88 cm with 2, 4, 6, and 8 rings of detector blocks (AFOV 7.8, 15.5, 23.3, and 31.0 cm). Fully 3D acquisition mode was compared to full collimation (2D) and partial collimation (2.5D) modes. Counting rates were estimated for a 200 cm long version of the 20 cm diameter NEMA count-rate phantom and for an anthropomorphic object based on a patient scan. We estimated the live-time characteristics of the scanner from measured count-rate data and applied that estimate to the simulated results to obtain NEC as a function of object activity. We found NEC increased as a quadratic function of AFOV for 3D mode, and linearly in 2D mode. Partial collimation provided the highest overall NEC on the 2-block system and fully 3D mode provided the highest NEC on the 8-block system for clinically relevant activities. On the 4-, and 6-block systems 3D mode NEC was highest up to ~300 MBq in the anthropomorphic phantom, above which 3D NEC dropped rapidly, and 2.5D NEC was highest. Projected total scan time to achieve NEC-density that matches current clinical practice in a typical oncology exam averaged 9, 15, 24, and 61 min for the 8-, 6-, 4-, and 2-block ring systems, when using optimal collimation. Increasing the AFOV should provide a greater than proportional increase in NEC, potentially benefiting patient throughput-to-cost ratio. Conversely, by using appropriate collimation, a two-ring (7.8 cm AFOV) system could acquire whole-body scans achieving NEC-density levels comparable to current standards within long, but feasible, scan times.
A time-domain fluorescence diffusion optical tomography system for breast tumor diagnosis
NASA Astrophysics Data System (ADS)
Zhang, Wei; Gao, Feng; Wu, LinHui; Ma, Wenjuan; Yang, Fang; Zhou, Zhongxing; Zhang, Limin; Zhao, Huijuan
2011-02-01
A prototype time-domain fluorescence diffusion optical tomography (FDOT) system using near-infrared light is presented. The system employs two pulsed light sources, 32 source fibers and 32 detection channels, working separately for acquiring the temporal distribution of the photon flux on the tissue surface. The light sources are provided by low power picosecond pulsed diode lasers at wavelengths of 780 nm and 830 nm, and a 1×32-fiber-optic-switch sequentially directs light sources to the object surface through 32 source fibers. The light signals re-emitted from the object are collected by 32 detection fibers connected to four 8×1 fiber-optic-switch and then routed to four time-resolved measuring channels, each of which consists of a collimator, a filter wheel, a photomultiplier tube (PMT) photon-counting head and a time-correlated single photon counting (TCSPC) channel. The performance and efficacy of the designed multi-channel PMT-TCSPC system are assessed by reconstructing the fluorescent yield and lifetime images of a solid phantom.
Vehicle and cargo container inspection system for drugs
NASA Astrophysics Data System (ADS)
Verbinski, Victor V.; Orphan, Victor J.
1999-06-01
A vehicle and cargo container inspection system has been developed which uses gamma-ray radiography to produce digital images useful for detection of drugs and other contraband. The system is comprised of a 1 Ci Cs137 gamma-ray source collimated into a fan beam which is aligned with a linear array of NaI gamma-ray detectors located on the opposite side of the container. The NaI detectors are operated in the pulse-counting mode. A digital image of the vehicle or container is obtained by moving the aligned source and detector array relative to the object. Systems have been demonstrated in which the object is stationary (source and detector array move on parallel tracks) and in which the object moves past a stationary source and detector array. Scanning speeds of ˜30 cm/s with a pixel size (at the object) of ˜1 cm have been achieved. Faster scanning speeds of ˜2 m/s have been demonstrated on railcars with more modest spatial resolution (4 cm pixels). Digital radiographic images are generated from the detector count rates. These images, recorded on a PC-based data acquisition and display system, are shown from several applications: 1) inspection of trucks and containers at a border crossing, 2) inspection of railcars at a border crossing, 3) inspection of outbound cargo containers for stolen automobiles, and 4) inspection of trucks and cars for terrorist bombs.
The Power of 2: How an Apparently Irregular Numeration System Facilitates Mental Arithmetic
ERIC Educational Resources Information Center
Bender, Andrea; Beller, Sieghard
2017-01-01
Mangarevan traditionally contained two numeration systems: a general one, which was highly regular, decimal, and extraordinarily extensive; and a specific one, which was restricted to specific objects, based on diverging counting units, and interspersed with binary steps. While most of these characteristics are shared by numeration systems in…
Individuation of objects and events: a developmental study.
Wagner, Laura; Carey, Susan
2003-12-01
This study investigates children's ability to use language to guide their choice of individuation criterion in the domains of objects and events. Previous work (Shipley, E. F., & Shepperson, B. (1990). Countable entities: developmental changes. Cognition, 34, 109-136.) has shown that children have a strong bias to use a spatio-temporal individuation strategy when counting objects and that children will ignore a conflicting linguistic description in favor of this spatio-temporal bias. Experiment 1 asked children (3-, 4-, and 5-year-olds) and adults to count objects and events under different linguistic descriptions. In the object task, subjects counted pictures of familiar objects split into multiple pieces (as in Shipley, E. F., & Shepperson, B. (1990). Countable entities: developmental changes. Cognition, 34, 109-136.) and described either using an appropriate kind label (e.g. "car") or the general term "thing". In the event task, subjects watched short animated movies consisting of a goal-oriented event achieved via multiple, temporally separated steps. The events were described either with an appropriate telic predicate targeting the goal (e.g. "paint a flower") or with an atelic predicate targeting the steps in the process (e.g. "paint") and the subjects' task was to count the events. Relative to adults, children preferred a spatio-temporal counting strategy in both tasks; there was no difference among the three groups of children. However, children were able to significantly change their counting strategy to follow the linguistic description in the event but not the object task. Experiment 2 extended the object task to include counting of other types of non-spatio-temporal units such as sub-parts of objects and collections. Results showed that children could use the linguistic descriptions to guide their counting strategy for these new items, though they continued to show a bias for a spatio-temporal individuation strategy with the collections. We suggest potential cognitive origins for the spatio-temporal individuation bias and how it interacts with children's developing linguistic knowledge.
Liu, Zhi; Sun, Yongzhu; Chang, Haifeng; Cui, Pengcheng
2014-01-01
Objective This study was designed to establish a low dose salicylate-induced tinnitus rat model and to investigate whether central or peripheral auditory system is involved in tinnitus. Methods Lick suppression ratio (R), lick count and lick latency of conditioned rats in salicylate group (120 mg/kg, intraperitoneally) and saline group were first compared. Bilateral auditory nerves were ablated in unconditioned rats and lick count and lick latency were compared before and after ablation. The ablation was then performed in conditioned rats and lick count and lick latency were compared between salicylate group and saline group and between ablated and unablated salicylate groups. Results Both the R value and the lick count in salicylate group were significantly higher than those in saline group and lick latency in salicylate group was significantly shorter than that in saline group. No significant changes were observed in lick count and lick latency before and after ablation. After ablation, lick count and lick latency in salicylate group were significantly higher and shorter respectively than those in saline group, but they were significantly lower and longer respectively than those in unablated salicylate group. Conclusion A low dose of salicylate (120 mg/kg) can induce tinnitus in rats and both central and peripheral auditory systems participate in the generation of salicylate-induced tinnitus. PMID:25269067
Veta, Mitko; van Diest, Paul J.; Jiwa, Mehdi; Al-Janabi, Shaimaa; Pluim, Josien P. W.
2016-01-01
Background Tumor proliferation speed, most commonly assessed by counting of mitotic figures in histological slide preparations, is an important biomarker for breast cancer. Although mitosis counting is routinely performed by pathologists, it is a tedious and subjective task with poor reproducibility, particularly among non-experts. Inter- and intraobserver reproducibility of mitosis counting can be improved when a strict protocol is defined and followed. Previous studies have examined only the agreement in terms of the mitotic count or the mitotic activity score. Studies of the observer agreement at the level of individual objects, which can provide more insight into the procedure, have not been performed thus far. Methods The development of automatic mitosis detection methods has received large interest in recent years. Automatic image analysis is viewed as a solution for the problem of subjectivity of mitosis counting by pathologists. In this paper we describe the results from an interobserver agreement study between three human observers and an automatic method, and make two unique contributions. For the first time, we present an analysis of the object-level interobserver agreement on mitosis counting. Furthermore, we train an automatic mitosis detection method that is robust with respect to staining appearance variability and compare it with the performance of expert observers on an “external” dataset, i.e. on histopathology images that originate from pathology labs other than the pathology lab that provided the training data for the automatic method. Results The object-level interobserver study revealed that pathologists often do not agree on individual objects, even if this is not reflected in the mitotic count. The disagreement is larger for objects from smaller size, which suggests that adding a size constraint in the mitosis counting protocol can improve reproducibility. The automatic mitosis detection method can perform mitosis counting in an unbiased way, with substantial agreement with human experts. PMID:27529701
Veta, Mitko; van Diest, Paul J; Jiwa, Mehdi; Al-Janabi, Shaimaa; Pluim, Josien P W
2016-01-01
Tumor proliferation speed, most commonly assessed by counting of mitotic figures in histological slide preparations, is an important biomarker for breast cancer. Although mitosis counting is routinely performed by pathologists, it is a tedious and subjective task with poor reproducibility, particularly among non-experts. Inter- and intraobserver reproducibility of mitosis counting can be improved when a strict protocol is defined and followed. Previous studies have examined only the agreement in terms of the mitotic count or the mitotic activity score. Studies of the observer agreement at the level of individual objects, which can provide more insight into the procedure, have not been performed thus far. The development of automatic mitosis detection methods has received large interest in recent years. Automatic image analysis is viewed as a solution for the problem of subjectivity of mitosis counting by pathologists. In this paper we describe the results from an interobserver agreement study between three human observers and an automatic method, and make two unique contributions. For the first time, we present an analysis of the object-level interobserver agreement on mitosis counting. Furthermore, we train an automatic mitosis detection method that is robust with respect to staining appearance variability and compare it with the performance of expert observers on an "external" dataset, i.e. on histopathology images that originate from pathology labs other than the pathology lab that provided the training data for the automatic method. The object-level interobserver study revealed that pathologists often do not agree on individual objects, even if this is not reflected in the mitotic count. The disagreement is larger for objects from smaller size, which suggests that adding a size constraint in the mitosis counting protocol can improve reproducibility. The automatic mitosis detection method can perform mitosis counting in an unbiased way, with substantial agreement with human experts.
Space Transportation System Availability Requirement and Its Influencing Attributes Relationships
NASA Technical Reports Server (NTRS)
Rhodes, Russell E.; Adams, Timothy C.; McCleskey, Carey M.
2008-01-01
It is important that engineering and management accept the need for an availability requirement that is derived with its influencing attributes. It is the intent of this paper to provide the visibility of relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability. Also important to provide bounds of the variables providing engineering the insight required to control the system's engineering solution, e.g., these influencing attributes become design requirements also. These variables will drive the need to provide integration of similar discipline functions or technology selection to allow control of the total parts count. The relationship of selecting a reliability requirement will place a constraint on parts count to achieve a given availability requirement or if allowed to increase the parts count will drive the system reliability requirement higher. They also provide the understanding for the relationship of mean repair time (or mean down time) to maintainability, e.g., accessibility for repair, and both the mean time between failure, e.g., reliability of hardware and availability. The concerns and importance of achieving a strong availability requirement is driven by the need for affordability, the choice of using the two launch solution for the single space application, or the need to control the spare parts count needed to support the long stay in either orbit or on the surface of the moon. Understanding the requirements before starting the architectural design concept will avoid considerable time and money required to iterate the design to meet the redesign and assessment process required to achieve the results required of the customer's space transportation system. In fact the impact to the schedule to being able to deliver the system that meets the customer's needs, goals, and objectives may cause the customer to compromise his desired operational goal and objectives resulting in considerable increased life cycle cost of the fielded space transportation system.
Space Transportation System Availability Requirements and Its Influencing Attributes Relationships
NASA Technical Reports Server (NTRS)
Rhodes, Russell E.; Adams, Timothy C.; McCleskey, Carey M.
2008-01-01
It is important that engineering and management accept the need for an availability requirement that is derived with its influencing attributes. It is the intent of this paper to provide the visibility of relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability. Also important to provide bounds of the variables providing engineering the insight required to control the system's engineering solution, e.g., these influencing attributes become design requirements also. These variables will drive the need to provide integration of similar discipline functions or technology selection to allow control of the total parts count. The relationship of selecting a reliability requirement will place a constraint on parts count to achieve a given availability requirement or if allowed to increase the parts count will drive the system reliability requirement higher. They also provide the understanding for the relationship of mean repair time (or mean down time) to maintainability, e.g., accessibility for repair, and both the mean time between failure, e.g., reliability of hardware and availability. The concerns and importance of achieving a strong availability requirement is driven by the need for affordability, the choice of using the two launch solution for the single space application, or the need to control the spare parts count needed to support the long stay in either orbit or on the surface of the moon. Understanding the requirements before starting the architectural design concept will avoid considerable time and money required to iterate the design to meet the redesign and assessment process required to achieve the results required of the customer's space transportation system. In fact the impact to the schedule to being able to deliver the system that meets the customer's needs, goals, and objectives may cause the customer to compromise his desired operational goal and objectives resulting in considerable increased life cycle cost of the fielded space transportation system.
Lee, Eun Gyung; Nelson, John H.; Kashon, Michael L.; Harper, Martin
2015-01-01
A Japanese round-robin study revealed that analysts who used a dark-medium (DM) objective lens reported higher fiber counts from American Industrial Hygiene Association (AIHA) Proficiency Analytical Testing (PAT) chrysotile samples than those using a standard objective lens, but the cause of this difference was not investigated at that time. The purpose of this study is to determine any major source of this difference by performing two sets of round-robin studies. For the first round-robin study, 15 AIHA PAT samples (five each of chrysotile and amosite generated by water-suspended method, and five chrysotile generated by aerosolization method) were prepared with relocatable cover slips and examined by nine laboratories. A second round-robin study was then performed with six chrysotile field sample slides by six out of nine laboratories who participated in the first round-robin study. In addition, two phase-shift test slides to check analysts’ visibility and an eight-form diatom test plate to compare resolution between the two objectives were examined. For the AIHA PAT chrysotile reference slides, use of the DM objective resulted in consistently higher fiber counts (1.45 times for all data) than the standard objective (P-value < 0.05), regardless of the filter generation (water-suspension or aerosol) method. For the AIHA PAT amosite reference and chrysotile field sample slides, the fiber counts between the two objectives were not significantly different. No statistically significant differences were observed in the visibility of blocks of the test slides between the two objectives. Also, the DM and standard objectives showed no pattern of differences in viewing the fine lines and/or dots of each species images on the eight-form diatom test plate. Among various potential factors that might affect the analysts’ performance of fiber counts, this study supports the greater contrast caused by the different phase plate absorptions as the main cause of high counts for the AIHA PAT chrysotile slides using the DM objective. The comparison of fiber count ratios (DM/standard) between the AIHA PAT chrysotile samples and chrysotile field samples indicates that there is a fraction of fibers in the PAT samples approaching the theoretical limit of visibility of the phase-contrast microscope with 3-degree phase-shift. These fibers become more clearly visible through the greater contrast from the phase plate absorption of the DM objective. However, as such fibers are not present in field samples, no difference in counts between the two objectives was observed in this study. The DM objective, therefore, could be allowed for routine fiber counting as it will maintain continuity with risk assessments based on earlier phase-contrast microscopy fiber counts from field samples. Published standard methods would need to be modified to allow a higher aperture specification for the objective. PMID:25737333
Sonja N. Oswalt; Thomas J. Brandeis; David W. Steadman; Scott K. Robinson
2009-01-01
We conducted double-observer point counts of birds from December 3 to December 31, 2005, on preestablished permanent Forest Inventory and Analysis (FIA) plots and National Park Service System trails within the Virgin Islands National Park, St. John, U.S. Virgin Islands. We had three objectives: (1) to collect abundance and distribution data for wintering land birds,...
1988-07-01
and SEdward 11oke (We tat) 13a. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT (Year, Month, Day) 15. PAGE COUNT Interim FROM 86/10 TO 87/06...TABULATIONS OF ENLISTED MARKETS 1. INTRODUCTION The Aray Communications Objectives Measurement System survey has been designed to provide timely information to...1987. During that time 6774 youth, ages 16 through 24, com- pleted the 30 minute ACOMS youth interview. A similar volume is also available for the
Learning from People, Things, and Signs
ERIC Educational Resources Information Center
Hoffmann, Michael H. G.
2007-01-01
Starting from the observation that small children can count more objects than numbers--a phenomenon that I am calling the "lifeworld dependency of cognition"--and an analysis of finger calculation, the paper shows how learning can be explained as the development of cognitive systems. Parts of those systems are not only an individual's different…
2012-01-01
Background Smoking has been linked to low-grade systemic inflammation, a known risk factor for disease. This state is reflected in elevated white blood cell (WBC) count. Objective We analyzed the relationship between WBC count and smoking in healthy men and women across several age ranges who underwent preventive medical check-ups in the workplace. We also analysed the relationship between smoking and lung function. Methods Cross-sectional descriptive study in 163 459 men and 59 382 women aged between 16 and 70 years. Data analysed were smoking status, WBC count, and spirometry readings. Results Total WBC showed higher counts in both male and female smokers, around 1000 to 1300 cell/ml (t test, P < 0.001). Forced expiratory volume in 1 second (FEV1%) was higher in nonsmokers for both sexes between 25 to 54 years (t test, P < 0.001). Analysis of covariance showed a multiple variable effect of age, sex, smoking status, body mass index on WBC count. The relationship between WBC blood count and smoking status was confirmed after the sample was stratified for these variables. Smokers with airway obstruction measured by FEV1% were found to have higher WBC counts, in comparison to smokers with a normal FEV1% among similar age and BMI groups. Conclusions Smoking increases WBC count and affects lung function. The effects are evident across a wide age range, underlining the importance of initiating preventive measures as soon as an individual begins to smoke. PMID:22613769
Göbel, Silke M
2015-01-01
Most adults and children in cultures where reading text progresses from left to right also count objects from the left to the right side of space. The reverse is found in cultures with a right-to-left reading direction. The current set of experiments investigated whether vertical counting in the horizontal plane is also influenced by reading direction. Participants were either from a left-to-right reading culture (UK) or from a mixed (left-to-right and top-to-bottom) reading culture (Hong Kong). In Experiment 1, native English-speaking children and adults and native Cantonese-speaking children and adults performed three object counting tasks. Objects were presented flat on a table in a horizontal, vertical, and square display. Independent of culture, the horizontal array was mostly counted from left to right. While the majority of English-speaking children counted the vertical display from bottom to top, the majority of the Cantonese-speaking children as well as both Cantonese- and English-speaking adults counted the vertical display from top to bottom. This pattern was replicated in the counting pattern for squares: all groups except the English-speaking children started counting with the top left coin. In Experiment 2, Cantonese-speaking adults counted a square array of objects after they read a text presented to them either in left-to-right or in top-to-bottom reading direction. Most Cantonese-speaking adults started counting the array by moving horizontally from left to right. However, significantly more Cantonese-speaking adults started counting with a top-to-bottom movement after reading the text presented in a top-to-bottom reading direction than in a left-to-right reading direction. Our results show clearly that vertical counting in the horizontal plane is influenced by longstanding as well as more recent experience of reading direction.
Exaggerated, Mispredicted, and Misplaced: When "It's the Thought That Counts" in Gift Exchanges
ERIC Educational Resources Information Center
Zhang, Yan; Epley, Nicholas
2012-01-01
Gift-giving involves both the objective value of a gift and the symbolic meaning of the exchange. The objective value is sometimes considered of secondary importance as when people claim, "It's the thought that counts." We evaluated when and how mental state inferences count in gift exchanges. Because considering another's thoughts requires…
Azrael, Deborah; Cohen, Amy; Miller, Matthew; Thymes, Deonza; Wang, David Enze; Hemenway, David
2016-01-01
Objective. To evaluate the National Violent Death Reporting System (NVDRS) as a surveillance system for homicides by law enforcement officers. Methods. We assessed sensitivity and positive predictive value of the NVDRS “type of death” variable against our study count of homicides by police, which we derived from NVDRS coded and narrative data for states participating in NVDRS 2005 to 2012. We compared state counts of police homicides from NVDRS, Vital Statistics, and Federal Bureau of Investigation Supplementary Homicide Reports. Results. We identified 1552 police homicides in the 16 states. Positive predictive value and sensitivity of the NVDRS “type of death” variable for police homicides were high (98% and 90%, respectively). Counts from Vital Statistics and Supplementary Homicide Reports were 58% and 48%, respectively, of our study total; gaps varied widely by state. The annual rate of police homicide (0.24/100 000) varied 5-fold by state and 8-fold by race/ethnicity. Conclusions. NVDRS provides more complete data on police homicides than do existing systems. Policy Implications. Expanding NVDRS to all 50 states and making 2 improvements we identify will be an efficient way to provide the nation with more accurate, detailed data on homicides by law enforcement. PMID:26985611
Dearing, Chey G; Kilburn, Sally; Lindsay, Kevin S
2014-03-01
Sperm counts have been linked to several fertility outcomes making them an essential parameter of semen analysis. It has become increasingly recognised that Computer-Assisted Semen Analysis (CASA) provides improved precision over manual methods but that systems are seldom validated robustly for use. The objective of this study was to gather the evidence to validate or reject the Sperm Class Analyser (SCA) as a tool for routine sperm counting in a busy laboratory setting. The criteria examined were comparison with the Improved Neubauer and Leja 20-μm chambers, within and between field precision, sperm concentration linearity from a stock diluted in semen and media, accuracy against internal and external quality material, assessment of uneven flow effects and a receiver operating characteristic (ROC) analysis to predict fertility in comparison with the Neubauer method. This work demonstrates that SCA CASA technology is not a standalone 'black box', but rather a tool for well-trained staff that allows rapid, high-number sperm counting providing errors are identified and corrected. The system will produce accurate, linear, precise results, with less analytical variance than manual methods that correlate well against the Improved Neubauer chamber. The system provides superior predictive potential for diagnosing fertility problems.
High resolution, high rate x-ray spectrometer
Goulding, F.S.; Landis, D.A.
1983-07-14
It is an object of the invention to provide a pulse processing system for use with detected signals of a wide dynamic range which is capable of very high counting rates, with high throughput, with excellent energy resolution and a high signal-to-noise ratio. It is a further object to provide a pulse processing system wherein the fast channel resolving time is quite short and substantially independent of the energy of the detected signals. Another object is to provide a pulse processing system having a pile-up rejector circuit which will allow the maximum number of non-interfering pulses to be passed to the output. It is also an object of the invention to provide new methods for generating substantially symmetrically triangular pulses for use in both the main and fast channels of a pulse processing system.
Gross, Hans J
2011-09-01
Human inborn numerical competence means our ability to recognize object numbers precisely under circumstances which do not allow sequential counting. This archaic process has been called "subitizing," from the Latin "subito" = suddenly, immediately, indicating that the objects in question are presented to test persons only for a fraction of a second in order to prevent counting. In contrast, however, sequential counting, an outstanding cultural achievement of mankind, means to count "1, 2, 3, 4, 5, 6, 7, 8…" without a limit. The following essay will explain how the limit of numerical competence, i.e., the recognition of object numbers without counting, has been determined for humans and how this has been achieved for the first time in case of an invertebrate, the honeybee. Finally, a hypothesis explaining the influence of our limited, inborn numerical competence on counting in our times, e.g., in the Russian language, will be presented. Subitizing versus counting by young Down syndrome infants and autistics and the Savant syndrome will be discussed.
To bee or not to bee, this is the question…
2011-01-01
Human inborn numerical competence means our ability to recognize object numbers precisely under circumstances which do not allow sequential counting. This archaic process has been called “subitizing,” from the Latin “subito” = suddenly, immediately, indicating that the objects in question are presented to test persons only for a fraction of a second in order to prevent counting. In contrast, however, sequential counting, an outstanding cultural achievement of mankind, means to count “1, 2, 3, 4, 5, 6, 7, 8…” without a limit. The following essay will explain how the limit of numerical competence, i.e., the recognition of object numbers without counting, has been determined for humans and how this has been achieved for the first time in case of an invertebrate, the honeybee. Finally, a hypothesis explaining the influence of our limited, inborn numerical competence on counting in our times, e.g., in the Russian language, will be presented. Subitizing versus counting by young Down syndrome infants and autistics and the Savant syndrome will be discussed. PMID:22046473
Data reduction for cough studies using distribution of audio frequency content
2012-01-01
Background Recent studies suggest that objectively quantifying coughing in audio recordings offers a novel means to understand coughing and assess treatments. Currently, manual cough counting is the most accurate method for quantifying coughing. However, the demand of manually counting cough records is substantial, demonstrating a need to reduce record lengths prior to counting whilst preserving the coughs within them. This study tested the performance of an algorithm developed for this purpose. Methods 20 subjects were recruited (5 healthy smokers and non-smokers, 5 chronic cough, 5 chronic obstructive pulmonary disease and 5 asthma), fitted with an ambulatory recording system and recorded for 24 hours. The recordings produced were divided into 15 min segments and counted. Periods of inactive audio in each segment were removed using the median frequency and power of the audio signal and the resulting files re-counted. Results The median resultant segment length was 13.9 s (IQR 56.4 s) and median 24 hr recording length 62.4 min (IQR 100.4). A median of 0.0 coughs/h (IQR 0.0-0.2) were erroneously removed and the variability in the resultant cough counts was comparable to that between manual cough counts. The largest error was seen in asthmatic patients, but still only 1.0% coughs/h were missed. Conclusions These data show that a system which measures signal activity using the median audio frequency can substantially reduce record lengths without significantly compromising the coughs contained within them. PMID:23231789
A Neurological Enigma: The Inborn Numerical Competence of Humans and Animals
NASA Astrophysics Data System (ADS)
Gross, Hans J.
2012-03-01
"Subitizing" means our ability to recognize and memorize object numbers precisely under conditions where counting is impossible. This is an inborn archaic process which was named after the Latin "subito" = suddenly, immediately, indicating that the objects in question are presented to test persons only for the fraction of a second in order to prevent counting. Sequential counting, however, is an outstanding cultural achievement of mankind and means to count "1, 2, 3, 4, 5, 6, 7, 8 ..." without a limit. In contrast to inborn "subitizing", counting has to be trained, beginning in our early childhood with the help of our fingers. For humans we know since 140 years that we can "subitize" only up to 4 objects correctly and that mistakes occur from 5 objects on. Similar results have been obtained for a number of non-human vertebrates from salamanders to pigeons and dolphins. To our surprise, we have detected this inborn numerical competence for the first time in case of an invertebrate, the honeybee which recognizes and memorizes 3 to 4 objects under rigorous test conditions. This common ability of humans and honeybees to "subitize" up to 4 objects correctly and the miraculous but rare ability of persons with Savant syndrome to "subitize" more than hundred objects precisely raises a number of intriguing questions concerning the evolution and the significance of this biological enigma.
Development of an Object-Oriented Turbomachinery Analysis Code within the NPSS Framework
NASA Technical Reports Server (NTRS)
Jones, Scott M.
2014-01-01
During the preliminary or conceptual design phase of an aircraft engine, the turbomachinery designer has a need to estimate the effects of a large number of design parameters such as flow size, stage count, blade count, radial position, etc. on the weight and efficiency of a turbomachine. Computer codes are invariably used to perform this task however, such codes are often very old, written in outdated languages with arcane input files, and rarely adaptable to new architectures or unconventional layouts. Given the need to perform these kinds of preliminary design trades, a modern 2-D turbomachinery design and analysis code has been written using the Numerical Propulsion System Simulation (NPSS) framework. This paper discusses the development of the governing equations and the structure of the primary objects used in OTAC.
NASA Astrophysics Data System (ADS)
Yanbe, Yutaka; Sato, Eiichi; Chiba, Hiraku; Maeda, Tomoko; Matsushita, Ryo; Oda, Yasuyuki; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira
2013-09-01
X-ray fluorescence (XRF) analysis is useful for mapping various atoms in objects. Bremsstrahlung X-rays with energies beyond tantalum (Ta) K-edge energy 67.4 keV are absorbed effectively using a 100-µm-thick Ta filter, and the filtered X-rays including tungsten (W) Kα rays are absorbed by gadolinium (Gd) atoms in objects. The Gd XRF is then produced from Gd atoms in the objects and is counted by a cadmium telluride (CdTe) detector. Gd Kα photons with a maximum count rate of 1 kilo counts per second are dispersed using a multichannel analyzer, and the number of photons is counted by a counter card. The distance between the CdTe detector and the object is minimized to 40 mm to increase the count rate. The object is scanned using an x-y stage with a velocity of 5.0 mm/s, and Gd mapping are shown on a computer monitor. The scan steps of the x- and y-axes were both 2.5 mm, and the photon-counting time per mapping point was 0.5 s. We obtained Gd XRF images at high contrast, and Gd Kα photons were easily detected from cancerous regions in a nude mouse placed behind a 20-mm-thick poly(methyl methacrylate) plate.
Sortal Concepts and Pragmatic Inference in Children's Early Quantification of Objects
ERIC Educational Resources Information Center
Srinivasan, Mahesh; Chestnut, Eleanor; Li, Peggy; Barner, David
2013-01-01
It is typically assumed that count nouns like "fork" act as logical sortals, specifying whether objects are countable units of a kind (e.g., that a whole fork counts as "one fork") or not (e.g., that a piece of a fork does not count as "one fork"). In four experiments, we provide evidence from linguistic and conceptual development that nouns do…
10-decade wide-range neutron-monitoring system. Final test report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green, W.K.
The objective of Project Agreement 49 was to design, fabricate, test, and evaluate under actual nuclear reactor operating conditions, one prototype counting-Campbelling wide-range type thermal neutron flux measurement channel. This report describes the basic system designed for PA 49, and describes and presents the results of tests conducted on the system. Individual module descriptions and schematics are contained in the instruction manual which was issued with the system.
Using virtual reality to test the regularity priors used by the human visual system
NASA Astrophysics Data System (ADS)
Palmer, Eric; Kwon, TaeKyu; Pizlo, Zygmunt
2017-09-01
Virtual reality applications provide an opportunity to test human vision in well-controlled scenarios that would be difficult to generate in real physical spaces. This paper presents a study intended to evaluate the importance of the regularity priors used by the human visual system. Using a CAVE simulation, subjects viewed virtual objects in a variety of experimental manipulations. In the first experiment, the subject was asked to count the objects in a scene that was viewed either right-side-up or upside-down for 4 seconds. The subject counted more accurately in the right-side-up condition regardless of the presence of binocular disparity or color. In the second experiment, the subject was asked to reconstruct the scene from a different viewpoint. Reconstructions were accurate, but the position and orientation error was twice as high when the scene was rotated by 45°, compared to 22.5°. Similarly to the first experiment, there was little difference between monocular and binocular viewing. In the third experiment, the subject was asked to adjust the position of one object to match the depth extent to the frontal extent among three objects. Performance was best with symmetrical objects and became poorer with asymmetrical objects and poorest with only small circular markers on the floor. Finally, in the fourth experiment, we demonstrated reliable performance in monocular and binocular recovery of 3D shapes of objects standing naturally on the simulated horizontal floor. Based on these results, we conclude that gravity, horizontal ground, and symmetry priors play an important role in veridical perception of scenes.
Object-oriented productivity metrics
NASA Technical Reports Server (NTRS)
Connell, John L.; Eller, Nancy
1992-01-01
Software productivity metrics are useful for sizing and costing proposed software and for measuring development productivity. Estimating and measuring source lines of code (SLOC) has proven to be a bad idea because it encourages writing more lines of code and using lower level languages. Function Point Analysis is an improved software metric system, but it is not compatible with newer rapid prototyping and object-oriented approaches to software development. A process is presented here for counting object-oriented effort points, based on a preliminary object-oriented analysis. It is proposed that this approach is compatible with object-oriented analysis, design, programming, and rapid prototyping. Statistics gathered on actual projects are presented to validate the approach.
Poka-yoke process controller: designed for individuals with cognitive impairments.
Erlandson, R F; Sant, D
1998-01-01
Poka-yoke is a Japanese term meaning "error proofing." Poka-yoke techniques were developed to achieve zero defects in manufacturing and assembly processes. The application of these techniques tends to reduce both the physical and cognitive demands of tasks and thereby make them more accessible. Poka-yoke interventions create a dialogue between the worker and the process, and this dialogue provides the feedback necessary for workers to prevent errors. For individuals with cognitive impairments, weighing and counting tasks can be difficult or impossible. Interventions that provide sufficient feedback to workers without disabilities tend to be too subtle for workers with cognitive impairments; hence, the feedback must be enhanced. The Poka-Yoke Controller (PYC) was designed to assist individuals with counting and weighing tasks. The PYC interfaces to an Ohaus CT6000 digital scale for weighing parts and for counting parts by weight. It also interfaces to sensors and switches for object counting tasks. The PYC interfaces to a variety of programmable voice output devices so that voice feedback or prompting can be provided at specific points in the weighing or counting process. The PYC can also be interfaced to conveyor systems, indexed turntables, and other material handling systems for coordinated counting and material handling operations. In all of our applications to date, we have observed improved worker performance, improved process quality, and greater worker independence. These observed benefits have also significantly reduced the need for staff intervention. The process controller is described and three applications are presented: a weighing task and two counting applications.
Real lasers and other deformed objects
NASA Technical Reports Server (NTRS)
Solomon, Allan I.
1995-01-01
In this talk we re-examine three important properties of quantum laser systems: (1) photon counting statistics; (2) squeezing; and (3) signal-to-quantum noise ratio. None of these phenomena depends on the choice of hamiltonian; indeed, we analyze them initially without restriction to any specific form of the commutation relations.
Adaptive Search through Constraint Violations
1990-01-01
underly counting (Gelman & Gallistel , 1978; Gelman & Meck, 1986). Modifying slightly the analysis by Gelman and Gallistel (1978), we identify three...understanding of counting, Gelman and Gallistel (1978) invented two non-standard counting tasks, ordered counting, in which the objects are counted In... Gallistel , 1978; Gelman & Meck, 1986). The most plausible explanation for this flexibility is that children can derive the control knowledge for the
Image and information management system
NASA Technical Reports Server (NTRS)
Robertson, Tina L. (Inventor); Raney, Michael C. (Inventor); Dougherty, Dennis M. (Inventor); Kent, Peter C. (Inventor); Brucker, Russell X. (Inventor); Lampert, Daryl A. (Inventor)
2009-01-01
A system and methods through which pictorial views of an object's configuration, arranged in a hierarchical fashion, are navigated by a person to establish a visual context within the configuration. The visual context is automatically translated by the system into a set of search parameters driving retrieval of structured data and content (images, documents, multimedia, etc.) associated with the specific context. The system places ''hot spots'', or actionable regions, on various portions of the pictorials representing the object. When a user interacts with an actionable region, a more detailed pictorial from the hierarchy is presented representing that portion of the object, along with real-time feedback in the form of a popup pane containing information about that region, and counts-by-type reflecting the number of items that are available within the system associated with the specific context and search filters established at that point in time.
Image and information management system
NASA Technical Reports Server (NTRS)
Robertson, Tina L. (Inventor); Kent, Peter C. (Inventor); Raney, Michael C. (Inventor); Dougherty, Dennis M. (Inventor); Brucker, Russell X. (Inventor); Lampert, Daryl A. (Inventor)
2007-01-01
A system and methods through which pictorial views of an object's configuration, arranged in a hierarchical fashion, are navigated by a person to establish a visual context within the configuration. The visual context is automatically translated by the system into a set of search parameters driving retrieval of structured data and content (images, documents, multimedia, etc.) associated with the specific context. The system places hot spots, or actionable regions, on various portions of the pictorials representing the object. When a user interacts with an actionable region, a more detailed pictorial from the hierarchy is presented representing that portion of the object, along with real-time feedback in the form of a popup pane containing information about that region, and counts-by-type reflecting the number of items that are available within the system associated with the specific context and search filters established at that point in time.
Automated Micro-Object Detection for Mobile Diagnostics Using Lens-Free Imaging Technology
Roy, Mohendra; Seo, Dongmin; Oh, Sangwoo; Chae, Yeonghun; Nam, Myung-Hyun; Seo, Sungkyu
2016-01-01
Lens-free imaging technology has been extensively used recently for microparticle and biological cell analysis because of its high throughput, low cost, and simple and compact arrangement. However, this technology still lacks a dedicated and automated detection system. In this paper, we describe a custom-developed automated micro-object detection method for a lens-free imaging system. In our previous work (Roy et al.), we developed a lens-free imaging system using low-cost components. This system was used to generate and capture the diffraction patterns of micro-objects and a global threshold was used to locate the diffraction patterns. In this work we used the same setup to develop an improved automated detection and analysis algorithm based on adaptive threshold and clustering of signals. For this purpose images from the lens-free system were then used to understand the features and characteristics of the diffraction patterns of several types of samples. On the basis of this information, we custom-developed an automated algorithm for the lens-free imaging system. Next, all the lens-free images were processed using this custom-developed automated algorithm. The performance of this approach was evaluated by comparing the counting results with standard optical microscope results. We evaluated the counting results for polystyrene microbeads, red blood cells, HepG2, HeLa, and MCF7 cells lines. The comparison shows good agreement between the systems, with a correlation coefficient of 0.91 and linearity slope of 0.877. We also evaluated the automated size profiles of the microparticle samples. This Wi-Fi-enabled lens-free imaging system, along with the dedicated software, possesses great potential for telemedicine applications in resource-limited settings. PMID:27164146
King, Michael A; Scotty, Nicole; Klein, Ronald L; Meyer, Edwin M
2002-10-01
Assessing the efficacy of in vivo gene transfer often requires a quantitative determination of the number, size, shape, or histological visualization characteristics of biological objects. The optical fractionator has become a choice stereological method for estimating the number of objects, such as neurons, in a structure, such as a brain subregion. Digital image processing and analytic methods can increase detection sensitivity and quantify structural and/or spectral features located in histological specimens. We describe a hardware and software system that we have developed for conducting the optical fractionator process. A microscope equipped with a video camera and motorized stage and focus controls is interfaced with a desktop computer. The computer contains a combination live video/computer graphics adapter with a video frame grabber and controls the stage, focus, and video via a commercial imaging software package. Specialized macro programs have been constructed with this software to execute command sequences requisite to the optical fractionator method: defining regions of interest, positioning specimens in a systematic uniform random manner, and stepping through known volumes of tissue for interactive object identification (optical dissectors). The system affords the flexibility to work with count regions that exceed the microscope image field size at low magnifications and to adjust the parameters of the fractionator sampling to best match the demands of particular specimens and object types. Digital image processing can be used to facilitate object detection and identification, and objects that meet criteria for counting can be analyzed for a variety of morphometric and optical properties. Copyright 2002 Elsevier Science (USA)
The AOLI low-order non-linear curvature wavefront sensor: laboratory and on-sky results
NASA Astrophysics Data System (ADS)
Crass, Jonathan; King, David; MacKay, Craig
2014-08-01
Many adaptive optics (AO) systems in use today require the use of bright reference objects to determine the effects of atmospheric distortions. Typically these systems use Shack-Hartmann Wavefront sensors (SHWFS) to distribute incoming light from a reference object between a large number of sub-apertures. Guyon et al. evaluated the sensitivity of several different wavefront sensing techniques and proposed the non-linear Curvature Wavefront Sensor (nlCWFS) offering improved sensitivity across a range of orders of distortion. On large ground-based telescopes this can provide nearly 100% sky coverage using natural guide stars. We present work being undertaken on the nlCWFS development for the Adaptive Optics Lucky Imager (AOLI) project. The wavefront sensor is being developed as part of a low-order adaptive optics system for use in a dedicated instrument providing an AO corrected beam to a Lucky Imaging based science detector. The nlCWFS provides a total of four reference images on two photon-counting EMCCDs for use in the wavefront reconstruction process. We present results from both laboratory work using a calibration system and the first on-sky data obtained with the nlCWFS at the 4.2 metre William Herschel Telescope, La Palma. In addition, we describe the updated optical design of the wavefront sensor, strategies for minimising intrinsic effects and methods to maximise sensitivity using photon-counting detectors. We discuss on-going work to develop the high speed reconstruction algorithm required for the nlCWFS technique. This includes strategies to implement the technique on graphics processing units (GPUs) and to minimise computing overheads to obtain a prior for a rapid convergence of the wavefront reconstruction. Finally we evaluate the sensitivity of the wavefront sensor based upon both data and low-photon count strategies.
Zhang, Hui; Guo, Peixuan
2014-05-15
Direct counting of biomolecules within biological complexes or nanomachines is demanding. Single molecule counting using optical microscopy is challenging due to the diffraction limit. The single molecule photobleaching (SMPB) technology for direct counting developed by our team (Shu et al., 2007 [18]; Zhang et al., 2007 [19]) offers a simple and straightforward method to determine the stoichiometry of molecules or subunits within biocomplexes or nanomachines at nanometer scales. Stoichiometry is determined by real-time observation of the number of descending steps resulted from the photobleaching of individual fluorophore. This technology has now been used extensively for single molecule counting of protein, RNA, and other macromolecules in a variety of complexes or nanostructures. Here, we elucidate the SMPB technology, using the counting of RNA molecules within a bacteriophage phi29 DNA-packaging biomotor as an example. The method described here can be applied to the single molecule counting of other molecules in other systems. The construction of a concise, simple and economical single molecule total internal reflection fluorescence (TIRF) microscope combining prism-type and objective-type TIRF is described. The imaging system contains a deep-cooled sensitive EMCCD camera with single fluorophore detection sensitivity, a laser combiner for simultaneous dual-color excitation, and a Dual-View™ imager to split the multiple outcome signals to different detector channels based on their wavelengths. Methodology of the single molecule photobleaching assay used to elucidate the stoichiometry of RNA on phi29 DNA packaging motor and the mechanism of protein/RNA interaction are described. Different methods for single fluorophore labeling of RNA molecules are reviewed. The process of statistical modeling to reveal the true copy number of the biomolecules based on binomial distribution is also described. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
McCall, Brian; Pierce, Mark; Graviss, Edward A.; Richards-Kortum, Rebecca R.; Tkaczyk, Tomasz S.
2016-03-01
A miniature objective designed for digital detection of Mycobacterium tuberculosis (MTB) was evaluated for diagnostic accuracy. The objective was designed for array microscopy, but fabricated and evaluated at this stage of development as a single objective. The counts and diagnoses of patient samples were directly compared for digital detection and standard microscopy. The results were found to be correlated and highly concordant. The evaluation of this lens by direct comparison to standard fluorescence sputum smear microscopy presented unique challenges and led to some new insights in the role played by the system parameters of the microscope. The design parameters and how they were developed are reviewed in light of these results. New system parameters are proposed with the goal of easing the challenges of evaluating the miniature objective and maintaining the optical performance that produced the agreeable results presented without over-optimizing. A new design is presented that meets and exceeds these criteria.
Yun, Jonghyun; Lee, Hyunyoung; Yang, Wonjae
2017-01-01
Objective Serum prostate-specific antigen (PSA) may be elevated in healthy men with systemic inflammation. We aimed to investigate the association between systemic inflammation markers and serum PSA in a healthy Korean population. Material and methods A cohort of 20,151 healthy native Korean men without prostate disease between the ages of 40 and 65 years who underwent medical checkups were studied from January 2007 to December 2013. Serum total PSA and serum C-reactive protein concentrations, neutrophil, lymphocyte, and platelet counts were determined. The neutrophil-lymphocyte ratio (NLR) and platelet-lymphocyte ratio (PLR) were calculated. We checked the correlation between systemic inflammation markers and PSA. Results Data obtained from 18,800 healthy men were analyzed. The mean age of the study subjects was 50.72±7.62 years and the mean NLR was 1.764±0.804. Correlation analysis after adjustment for age and body mass index (BMI) revealed that neutrophil count (coefficient = 0.028, p value <0.001), and NLR (coefficient = 0.027, p value <0.001) correlated with PSA. Multivariate analysis using the full model revealed that age, neutrophil count and NLR were positively correlated with PSA (p<0.001, 0.001, and 0.043 respectively). Multivariate analysis using a stepwise model revealed that age, neutrophil count and NLR were positively correlated with PSA (p<0.001, 0.001, and 0.040, respectively) and BMI was negatively correlated with PSA (p<0.001). Conclusion Systemic inflammation markers are useful with a serum PSA in a healthy Korean population. NLR in particular is significantly associated with serum PSA. PMID:28861299
The Objectivity, Reliability, and Validity of the OSU Step Test for College Males
ERIC Educational Resources Information Center
Santa Maria, D. L.; And Others
1976-01-01
The O.S.U. Step Test was administered to 68 male university students to determine the objectivity of three methods of monitering heart rate--subjects count, investigator's count, and ECG records--with results indicating that the investigator was significantly more accurate in heart rate determination than were the subjects. (MB)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisk, William J.; Sullivan, Douglas
This pilot scale study evaluated the counting accuracy of two people counting systems that could be used in demand controlled ventilation systems to provide control signals for modulating outdoor air ventilation rates. The evaluations included controlled challenges of the people counting systems using pre-planned movements of occupants through doorways and evaluations of counting accuracies when naive occupants (i.e., occupants unaware of the counting systems) passed through the entrance doors of the building or room. The two people counting systems had high counting accuracy accuracies, with errors typically less than 10percent, for typical non-demanding counting events. However, counting errors were highmore » in some highly challenging situations, such as multiple people passing simultaneously through a door. Counting errors, for at least one system, can be very high if people stand in the field of view of the sensor. Both counting system have limitations and would need to be used only at appropriate sites and where the demanding situations that led to counting errors were rare.« less
Liu, G.; Van der Mark, E. J.; Verberk, J. Q. J. C.; Van Dijk, J. C.
2013-01-01
The objective of this study was to evaluate the application of flow cytometry total cell counts (TCCs) as a parameter to assess microbial growth in drinking water distribution systems and to determine the relationships between different parameters describing the biostability of treated water. A one-year sampling program was carried out in two distribution systems in The Netherlands. Results demonstrated that, in both systems, the biomass differences measured by ATP were not significant. TCC differences were also not significant in treatment plant 1, but decreased slightly in treatment plant 2. TCC values were found to be higher at temperatures above 15°C than at temperatures below 15°C. The correlation study of parameters describing biostability found no relationship among TCC, heterotrophic plate counts, and Aeromonas. Also no relationship was found between TCC and ATP. Some correlation was found between the subgroup of high nucleic acid content bacteria and ATP (R 2 = 0.63). Overall, the results demonstrated that TCC is a valuable parameter to assess the drinking water biological quality and regrowth; it can directly and sensitively quantify biomass, detect small changes, and can be used to determine the subgroup of active HNA bacteria that are related to ATP. PMID:23819117
A habitat-based point-count protocol for terrestrial birds, emphasizing Washington and Oregon.
Mark H. Huff; Kelly A. Bettinger; Howard L. Ferguson; Martin J. Brown; Bob. Altman
2000-01-01
We describe a protocol and provide a summary for point-count monitoring of landbirds that is designed for habitat-based objectives. Presentation is in four steps: preparation and planning, selecting monitoring sites, establishing monitoring stations, and conducting point counts. We describe the basis for doing habitat-based point counts, how they are organized, and how...
Exaggerated, mispredicted, and misplaced: when "it's the thought that counts" in gift exchanges.
Zhang, Yan; Epley, Nicholas
2012-11-01
Gift-giving involves both the objective value of a gift and the symbolic meaning of the exchange. The objective value is sometimes considered of secondary importance as when people claim, "It's the thought that counts." We evaluated when and how mental state inferences count in gift exchanges. Because considering another's thoughts requires motivation and deliberation, we predicted gift givers' thoughts would increase receivers' appreciation only when triggered to consider a giver's thoughts, such as when a friend gives a bad gift. Because gift givers do not experience this trigger, we expected they would mispredict when their thoughts count and when they do not. Three experiments support these predictions. A final experiment demonstrated that thoughts "count" for givers by increasing social connection to the receiver. These results suggest that mental state inferences are not automatic in social interactions and that inferences about how much thoughts count are systematically miscalibrated. (PsycINFO Database Record (c) 2012 APA, all rights reserved).
Photon-Counting Kinetic Inductance Detectors for the Origins Space Telescope
NASA Astrophysics Data System (ADS)
Noroozian, Omid
We propose to develop photon-counting Kinetic Inductance Detectors (KIDs) for the Origins Space Telescope (OST) and any predecessor missions, with the goal of producing background-limited photon-counting sensitivity, and with a preliminary technology demonstration in time to inform the Decadal Survey planning process. The OST, a midto far- infrared observatory concept, is being developed as a major NASA mission to be considered by the next Decadal Survey with support from NASA Headquarters. The objective of such a facility is to allow rapid spectroscopic surveys of the high redshift universe at 420-800 μm, using arrays of integrated spectrometers with moderate resolutions (R=λ/Δλ 1000), to create a powerful new data set for exploring galaxy evolution and the growth of structure in the Universe. A second objective of OST is to perform higher resolution (R 10,000-100,000) spectroscopic surveys at 20-300 µm, a uniquely powerful tool for exploring the evolution of protoplanetary disks into fledgling solar systems. Finally the OST aims to obtain sensitive mid-infrared (5-40 µm) spectroscopy of thermal emission from rocky planets in the habitable zone using the transit method. These OST science objectives are very exciting and represent a wellorganized community agreement. However, they are all impossible to reach without new detector technology, and the OST can’t be recommended or approved if suitable detectors do not exist. In all of the above instrument concepts, photon-counting direct detectors are mission-enabling and essential for reaching the sensitivity permitted by the cryogenic Origins Space Telescope and the performance required for its important science programs. Our group has developed an innovative design for an optically-coupled KID that can reach the photon-counting sensitivity required by the ambitious science goals of the OST mission. A KID is a planar microwave resonator patterned from a superconducting thin film, which responds to incident photons with a change in its resonance frequency and dissipation. This detector response is intrinsically frequency multiplexed, and consequently KIDs at different resonance frequencies can be read out using standard digital radio techniques, which enables multiplexing of 10,000s of detectors. In our photon-counting KID design we employ a small-volume (and thin) superconducting Al inductor to enhance the per-photon responsivity, and large parallel-plate NbTiN capacitors on single-crystal silicon-on-insulator (SOI) substrates to eliminate frequency noise. We have developed a comprehensive design demonstrating that photon-counting sensitivity is possible in a small-volume Al KID. In addition, we have already demonstrated ultra-high quality factors in resonators made of very thin ( 10 nm) Al films with long electron lifetimes. These are the critical material parameters for reaching photon-counting sensitivity levels. In our proposed work plan our objective is to implement these high quality films into our optically-coupled small-volume KID design and demonstrate photon-counting sensitivity. The successful development of our photon-counting technology will significantly increase the sensitivity of the OST mission, making it more scientifically competitive than one based on power detectors. Photon-counting at the background limit provides a x4 increase in observation speed over that of background-limited power detection, since there is no need to measure and subtract a zero point. Photon-counting detectors will enable an instrument on the OST to observe the fine structure lines of galaxies which are currently only observable at redshifts of z 1, out to redshifts of z=6, probing the early stages of galaxy, star and planet formation. Our photon-counting detectors will also enable entirely new science, including the mapping of the composition and evolution of water and other key volatiles in planet-forming materials around large samples of nearby young stars.
A two-dimensional intensified photodiode array for imaging spectroscopy
NASA Technical Reports Server (NTRS)
Tennyson, P. D.; Dymond, K.; Moos, H. W.; Feldman, P. D.; Mackey, E. F.
1986-01-01
The Johns Hopkins University is currently developing an instrument to fly aboard NASA's Space Shuttle as a Spartan payload in the late 1980s. This Spartan free flyer will obtain spatially resolved spectra of faint extended emission line objects in the wavelength range 750-1150 A at about 2-A resolution. The use of two-dimensional photon counting detectors will give simultaneous coverage of the 400 A spectral range and the 9 arc-minute spatial resolution along the spectrometer slit. The progress towards the flight detector is reported here with preliminary results from a laboratory breadboard detector, and a comparison with the one-dimensional detector developed for the Hopkins Ultraviolet Telescope. A hardware digital centroiding algorithm has been successfully implemented. The system is ultimately capable of 15-micron resolution in two dimensions at the image plane and can handle continuous counting rates of up to 8000 counts/s.
Tracking and people counting using Particle Filter Method
NASA Astrophysics Data System (ADS)
Sulistyaningrum, D. R.; Setiyono, B.; Rizky, M. S.
2018-03-01
In recent years, technology has developed quite rapidly, especially in the field of object tracking. Moreover, if the object under study is a person and the number of people a lot. The purpose of this research is to apply Particle Filter method for tracking and counting people in certain area. Tracking people will be rather difficult if there are some obstacles, one of which is occlusion. The stages of tracking and people counting scheme in this study include pre-processing, segmentation using Gaussian Mixture Model (GMM), tracking using particle filter, and counting based on centroid. The Particle Filter method uses the estimated motion included in the model used. The test results show that the tracking and people counting can be done well with an average accuracy of 89.33% and 77.33% respectively from six videos test data. In the process of tracking people, the results are good if there is partial occlusion and no occlusion
NASA Astrophysics Data System (ADS)
Chiba, Hiraku; Sato, Yuichi; Sato, Eiichi; Maeda, Tomoko; Matsushita, Ryo; Yanbe, Yutaka; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2012-10-01
An energy-dispersive (ED) X-ray computed tomography (CT) system is useful for carrying out monochromatic imaging by selecting optimal energy photons. CT is performed by repeated linear scans and rotations of an object. X-ray photons from the object are detected by the cadmium telluride (CdTe) detector, and event pulses of X-ray photons are produced using charge-sensitive and shaping amplifiers. The lower photon energy is determined by a comparator, and the maximum photon energy of 70 keV corresponds to the tube voltage. Logical pulses from the comparator are counted by a counter card through a differentiator to reduce pulse width and rise time. In the ED-CT system, tube voltage and current were 70 kV and 0.30 mA, respectively, and X-ray intensity was 18.2 µGy/s at 1.0 m from the source at a tube voltage of 70 kV. Demonstration of gadolinium K-edge CT for cancer diagnosis was carried out by selecting photons with energies ranging from 50.4 to 70 keV, and photon-count energy subtraction imaging from 30 to 50.3 keV was also performed.
A microkernel design for component-based parallel numerical software systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balay, S.
1999-01-13
What is the minimal software infrastructure and what type of conventions are needed to simplify development of sophisticated parallel numerical application codes using a variety of software components that are not necessarily available as source code? We propose an opaque object-based model where the objects are dynamically loadable from the file system or network. The microkernel required to manage such a system needs to include, at most: (1) a few basic services, namely--a mechanism for loading objects at run time via dynamic link libraries, and consistent schemes for error handling and memory management; and (2) selected methods that all objectsmore » share, to deal with object life (destruction, reference counting, relationships), and object observation (viewing, profiling, tracing). We are experimenting with these ideas in the context of extensible numerical software within the ALICE (Advanced Large-scale Integrated Computational Environment) project, where we are building the microkernel to manage the interoperability among various tools for large-scale scientific simulations. This paper presents some preliminary observations and conclusions from our work with microkernel design.« less
A Software Architecture for a Small Autonomous Underwater Vehicle Navigation System
1993-06-01
angle consistent with system accuracy objectives for the interim SANS system must be quantified. 12 DEPTH CHAC oCLIMB ANGLE HORIZONTAL DISTANCE Figure...Figure 4.1 illustrates the hardware interface. COMPUTER (ESP-8o80) D IG IT A L B I N A R GYRO SIGNAL BINARY BINARY HEADING DATA "\\DATA DEPTH /RS-232...Mode 3 of the 82C54 provides a square wave through any of the 3 counters in the 82C54. An initial count N is written to the counter control register
Generalized index for spatial data sets as a measure of complete spatial randomness
NASA Astrophysics Data System (ADS)
Hackett-Jones, Emily J.; Davies, Kale J.; Binder, Benjamin J.; Landman, Kerry A.
2012-06-01
Spatial data sets, generated from a wide range of physical systems can be analyzed by counting the number of objects in a set of bins. Previous work has been limited to equal-sized bins, which are inappropriate for some domains (e.g., circular). We consider a nonequal size bin configuration whereby overlapping or nonoverlapping bins cover the domain. A generalized index, defined in terms of a variance between bin counts, is developed to indicate whether or not a spatial data set, generated from exclusion or nonexclusion processes, is at the complete spatial randomness (CSR) state. Limiting values of the index are determined. Using examples, we investigate trends in the generalized index as a function of density and compare the results with those using equal size bins. The smallest bin size must be much larger than the mean size of the objects. We can determine whether a spatial data set is at the CSR state or not by comparing the values of a generalized index for different bin configurations—the values will be approximately the same if the data is at the CSR state, while the values will differ if the data set is not at the CSR state. In general, the generalized index is lower than the limiting value of the index, since objects do not have access to the entire region due to blocking by other objects. These methods are applied to two applications: (i) spatial data sets generated from a cellular automata model of cell aggregation in the enteric nervous system and (ii) a known plant data distribution.
2003-04-07
PERSON Rife, Dave RifeD@awc.carlisle.army.mil a. REPORT Unclassified b. ABSTRACT Unclassified c. THIS PAGE Unclassified 19b. TELEPHONE NUMBER International...38 WORD COUNT = 8975 39 40 ENDNOTES 1 COL Pete Zielinski , Director, Joint/Army concepts HQs TRADOC “Transformation Update” briefing slide #9, Briefing...Staff. Interviewed by author, 18 February 2003, Carlisle Barracks, PA. Zielinski , Pete, COL Director, Joint/Army concepts HQs TRADOC “Transformation
Language, procedures, and the non-perceptual origin of number word meanings.
Barner, David
2017-05-01
Perceptual representations of objects and approximate magnitudes are often invoked as building blocks that children combine to acquire the positive integers. Systems of numerical perception are either assumed to contain the logical foundations of arithmetic innately, or to supply the basis for their induction. I propose an alternative to this framework, and argue that the integers are not learned from perceptual systems, but arise to explain perception. Using cross-linguistic and developmental data, I show that small (~1-4) and large (~5+) numbers arise both historically and in individual children via distinct mechanisms, constituting independent learning problems, neither of which begins with perceptual building blocks. Children first learn small numbers using the same logic that supports other linguistic number marking (e.g. singular/plural). Years later, they infer the logic of counting from the relations between large number words and their roles in blind counting procedures, only incidentally associating number words with approximate magnitudes.
Surpassing Humans and Computers with JellyBean: Crowd-Vision-Hybrid Counting Algorithms.
Sarma, Akash Das; Jain, Ayush; Nandi, Arnab; Parameswaran, Aditya; Widom, Jennifer
2015-11-01
Counting objects is a fundamental image processisng primitive, and has many scientific, health, surveillance, security, and military applications. Existing supervised computer vision techniques typically require large quantities of labeled training data, and even with that, fail to return accurate results in all but the most stylized settings. Using vanilla crowd-sourcing, on the other hand, can lead to significant errors, especially on images with many objects. In this paper, we present our JellyBean suite of algorithms, that combines the best of crowds and computer vision to count objects in images, and uses judicious decomposition of images to greatly improve accuracy at low cost. Our algorithms have several desirable properties: (i) they are theoretically optimal or near-optimal , in that they ask as few questions as possible to humans (under certain intuitively reasonable assumptions that we justify in our paper experimentally); (ii) they operate under stand-alone or hybrid modes, in that they can either work independent of computer vision algorithms, or work in concert with them, depending on whether the computer vision techniques are available or useful for the given setting; (iii) they perform very well in practice, returning accurate counts on images that no individual worker or computer vision algorithm can count correctly, while not incurring a high cost.
Omeira, N; Barbour, E K; Nehme, P A; Hamadeh, S K; Zurayk, R; Bashour, I
2006-08-15
Chicken litter is produced in large quantities from all types of poultry raising activities. It is primarily used for land application, thus it is essential to analyze its properties before it is released to the environment. The objective of this study is to compare the microbiological and chemical properties of litter generated from layer and broiler chickens reared under intensive and free-range production systems. The microbiological analysis consisted of the enumeration of total bacteria, total coliforms, Staphylococcus species, Salmonella species and Clostridium perfringens. Chicken litter from layers reared under intensive and free range systems showed lower mean total bacterial count than the litter collected from chicken broilers reared under either of the two systems (P=0.0291). The litter from intensive layers had the lowest mean total coliform counts (P=0.0222) while the lowest Staphylococcus species count was observed in the litter from free-range layers (P=0.0077). The C. perfringens count was the lowest in chicken litter from intensively raised broilers and layers (P=0.0001). The chemical properties of litter from the different chicken types and production systems were compared based on determination of pH, electrical conductivity, carbon, nitrogen, phosphorus, potassium, cadmium and zinc. Litter from free-range broilers showed the highest pH value (P=0.0005); however, the electrical conductivity was higher in the litter from both intensive and free-range layers compared to the litter from both broiler production systems (P=0.0117). Chicken litter from intensive systems had higher nitrogen content than litter from free-range systems (P=0.0000). The total phosphorus was the lowest in free-range broiler litter (P=0.0001), while the total potassium was the lowest in litter from intensively managed broilers (P=0.0000). Zinc appeared higher in litter from layers compared to that from broilers (P=0.0101). The cadmium content was higher in the litter from free-range broilers and layers compared to that in the litter from intensively managed systems (P=0.0439). Staphylococcus species in the litter as well as cadmium concentrations seem to be the most critical parameters presenting risks on the environment and on human health. Based on the lowest coliform counts (an indication of water pollution), the high nutrient levels and the low cadmium values, litter from intensively managed layers appears as the most suitable for application on agricultural soils.
Automatic image acquisition processor and method
Stone, William J.
1986-01-01
A computerized method and point location system apparatus is disclosed for ascertaining the center of a primitive or fundamental object whose shape and approximate location are known. The technique involves obtaining an image of the object, selecting a trial center, and generating a locus of points having a predetermined relationship with the center. Such a locus of points could include a circle. The number of points overlying the object in each quadrant is obtained and the counts of these points per quadrant are compared. From this comparison, error signals are provided to adjust the relative location of the trial center. This is repeated until the trial center overlies the geometric center within the predefined accuracy limits.
Automatic image acquisition processor and method
Stone, W.J.
1984-01-16
A computerized method and point location system apparatus is disclosed for ascertaining the center of a primitive or fundamental object whose shape and approximate location are known. The technique involves obtaining an image of the object, selecting a trial center, and generating a locus of points having a predetermined relationship with the center. Such a locus of points could include a circle. The number of points overlying the object in each quadrant is obtained and the counts of these points per quadrant are compared. From this comparison, error signals are provided to adjust the relative location of the trial center. This is repeated until the trial center overlies the geometric center within the predefined accuracy limits.
Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota
2017-01-01
Objectives: Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. Methods: To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. Results: On five of the seven models, the inter-class correlations coefficient (ICC (3,1)) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1): 0.992-0.998. The false detection rates differed between the sitting conditions. Conclusions: These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation. PMID:28835575
Grey W. Pendleton
1995-01-01
Many factors affect the use of point counts for monitoring bird populations, including sampling strategies, variation in detection rates, and independence of sample points. The most commonly used sampling plans are stratified sampling, cluster sampling, and systematic sampling. Each of these might be most useful for different objectives or field situations. Variation...
ERIC Educational Resources Information Center
Camos, Valerie; Barrouillet, Pierre; Fayol, Michel
2001-01-01
Tested in three experiments hypothesis that coordinating saying number-words and pointing to each object to count requires use of the central executive and that cost of coordination decreases with age. Found that for 5- and 9-year-olds and adults, manipulating difficulty of each component affected counting performance but did not make coordination…
Imaging of blood cells based on snapshot Hyper-Spectral Imaging systems
NASA Astrophysics Data System (ADS)
Robison, Christopher J.; Kolanko, Christopher; Bourlai, Thirimachos; Dawson, Jeremy M.
2015-05-01
Snapshot Hyper-Spectral imaging systems are capable of capturing several spectral bands simultaneously, offering coregistered images of a target. With appropriate optics, these systems are potentially able to image blood cells in vivo as they flow through a vessel, eliminating the need for a blood draw and sample staining. Our group has evaluated the capability of a commercial Snapshot Hyper-Spectral imaging system, the Arrow system from Rebellion Photonics, in differentiating between white and red blood cells on unstained blood smear slides. We evaluated the imaging capabilities of this hyperspectral camera; attached to a microscope at varying objective powers and illumination intensity. Hyperspectral data consisting of 25, 443x313 hyperspectral bands with ~3nm spacing were captured over the range of 419 to 494nm. Open-source hyper-spectral data cube analysis tools, used primarily in Geographic Information Systems (GIS) applications, indicate that white blood cells features are most prominent in the 428-442nm band for blood samples viewed under 20x and 50x magnification over a varying range of illumination intensities. These images could potentially be used in subsequent automated white blood cell segmentation and counting algorithms for performing in vivo white blood cell counting.
Three-dimensional FLASH Laser Radar Range Estimation via Blind Deconvolution
2009-10-01
scene can result in errors due to several factors including the optical spatial impulse response, detector blurring, photon noise , timing jitter, and...estimation error include spatial blur, detector blurring, noise , timing jitter, and inter-sample targets. Unlike previous research, this paper ac- counts...for pixel coupling by defining the range image mathematical model as a 2D convolution between the system spatial impulse response and the object (target
Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.
Klumpp, John; Brandl, Alexander
2015-03-01
A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.
Schmitz, Christoph; Eastwood, Brian S.; Tappan, Susan J.; Glaser, Jack R.; Peterson, Daniel A.; Hof, Patrick R.
2014-01-01
Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D) stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D) “cell counting” approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38 and 99% and false-positive rates from 3.6 to 82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections. PMID:24847213
Kwon, Seung Yong; Pham, Tuyen Danh; Park, Kang Ryoung; Jeong, Dae Sik; Yoon, Sungsoo
2016-06-11
Fitness classification is a technique to assess the quality of banknotes in order to determine whether they are usable. Banknote classification techniques are useful in preventing problems that arise from the circulation of substandard banknotes (such as recognition failures, or bill jams in automated teller machines (ATMs) or bank counting machines). By and large, fitness classification continues to be carried out by humans, and this can cause the problem of varying fitness classifications for the same bill by different evaluators, and requires a lot of time. To address these problems, this study proposes a fuzzy system-based method that can reduce the processing time needed for fitness classification, and can determine the fitness of banknotes through an objective, systematic method rather than subjective judgment. Our algorithm was an implementation to actual banknote counting machine. Based on the results of tests on 3856 banknotes in United States currency (USD), 3956 in Korean currency (KRW), and 2300 banknotes in Indian currency (INR) using visible light reflection (VR) and near-infrared light transmission (NIRT) imaging, the proposed method was found to yield higher accuracy than prevalent banknote fitness classification methods. Moreover, it was confirmed that the proposed algorithm can operate in real time, not only in a normal PC environment, but also in an embedded system environment of a banknote counting machine.
Kwon, Seung Yong; Pham, Tuyen Danh; Park, Kang Ryoung; Jeong, Dae Sik; Yoon, Sungsoo
2016-01-01
Fitness classification is a technique to assess the quality of banknotes in order to determine whether they are usable. Banknote classification techniques are useful in preventing problems that arise from the circulation of substandard banknotes (such as recognition failures, or bill jams in automated teller machines (ATMs) or bank counting machines). By and large, fitness classification continues to be carried out by humans, and this can cause the problem of varying fitness classifications for the same bill by different evaluators, and requires a lot of time. To address these problems, this study proposes a fuzzy system-based method that can reduce the processing time needed for fitness classification, and can determine the fitness of banknotes through an objective, systematic method rather than subjective judgment. Our algorithm was an implementation to actual banknote counting machine. Based on the results of tests on 3856 banknotes in United States currency (USD), 3956 in Korean currency (KRW), and 2300 banknotes in Indian currency (INR) using visible light reflection (VR) and near-infrared light transmission (NIRT) imaging, the proposed method was found to yield higher accuracy than prevalent banknote fitness classification methods. Moreover, it was confirmed that the proposed algorithm can operate in real time, not only in a normal PC environment, but also in an embedded system environment of a banknote counting machine. PMID:27294940
Background compensation for a radiation level monitor
Keefe, D.J.
1975-12-01
Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.
Prognostic value of mitotic counts in breast cancer of Saudi Arabian patients.
Buhmeida, Abdelbaset; Al-Maghrabi, Jaudah; Merdad, Adnan; Al-Thubaity, Fatima; Chaudhary, Adeel; Gari, Mamdooh; Abuzenadah, Adel; Collan, Yrjö; Syrjänen, Kari; Al-Qahtani, Mohammed
2011-01-01
Quantitative methods in combination with other objective prognostic criteria can improve the evaluation of a cancer patient's prognosis, and possibly predict response to therapy. One of the important prognostic and predictive markers is the mitotic count, which has proven valuable in many aspects. In this study, the prognostic value of the mitotic count was assessed in breast cancer (BC) patients in Saudi Arabia. The study comprised a series of 87 patients diagnosed and treated for breast cancer at the Departments of Surgery and Oncology, King Abdul-Aziz University Hospital, between 2000 and 2008. Mitotic counts were carried out using a standard laboratory microscope (objective, × 40; field diameter, 420 μm). The number of mitotic figures in 10 consecutive high-power fields (hpf) from the most cellular area of the sample gave the mitotic activity index (MAI, mitotic figures/10 hpf). The standardized mitotic index (SMI) recorded the mitotic count as the number of mitotic figures by area of the neoplastic tissue in the microscopic field, thus the number of mitoses in 10 consecutive fields was corrected for the volume fraction and field size (mitotic figures/mm²). The means of MAI and SMI of the tumors in the entire series of 87 patients were 15 mitotic figures/10 hpf (range 4-45) and 4 mitotic figures/mm² (range 1-9), respectively. The mitotic counts were higher in advanced stages than in early cancer (p < 0.04). The mitotic counts were significantly larger in patients with high-grade tumor (p < 0.004) and in cases with tumor metastasis (p < 0.004). The mitotic counts were also significantly larger in the recurrent cases than in non-recurrent ones (p < 0.02). The quantitatively measurable mitotic counts of cancer cell nuclei are of significant prognostic value in invasive ductal carcinoma of the breast in Saudi Arabia and the mean cut-off values of MAI and SMI can be applied as objective (quantitative) criteria to distinguish breast cancer patients into groups with favorable and less favorable prognosis.
Choi, Woo June; Pepple, Kathryn L; Wang, Ruikang K
2018-05-24
In preclinical vision research, cell grading in small animal models is essential for the quantitative evaluation of intraocular inflammation. Here, we present a new and practical optical coherence tomography (OCT) image analysis method for the automated detection and counting of aqueous cells in the anterior chamber (AC) of a rodent model of uveitis. Anterior segment OCT (AS-OCT) images are acquired with a 100kHz swept-source OCT (SS-OCT) system. The proposed method consists of two steps. In the first step, we first despeckle and binarize each OCT image. After removing AS structures in the binary image, we then apply area thresholding to isolate cell-like objects. Potential cell candidates are selected based on their best fit to roundness. The second step performs the cell counting within the whole AC, in which additional cell tracking analysis is conducted on the successive OCT images to eliminate redundancy in cell counting. Finally, 3-D cell grading using the proposed method is demonstrated in longitudinal OCT imaging of a mouse model of anterior uveitis in vivo. Rendering of anterior segment (orange) of mouse eye and automatically counted anterior chamber cells (green). Inset is a top view of the rendering, showing the cell distribution across the anterior chamber. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Kitchener, Henry C; Gittins, Matthew; Desai, Mina; Smith, John H F; Cook, Gary; Roberts, Chris; Turnbull, Lesley
2015-03-01
Liquid-based cytology (LBC) for cervical screening would benefit from laboratory practice guidelines that define specimen adequacy for reporting of slides. The evidence base required to define cell adequacy should incorporate both ThinPrep™ (TP; Hologic, Inc., Bedford, MA, USA) and SurePath™ (SP; BD Diagnostics, Burlington, NC, USA), the two LBC systems used in the UK cervical screening programmes. The objectives of this study were to determine (1) current practice for reporting LBC in England, Wales and Scotland, (2) a reproducible method for cell counting, (3) the cellularity of slides classified as inadequate, negative or abnormal and (4) the impact of varying cellularity on the likelihood of detecting cytological abnormalities. The study involved four separate arms to pursue each of the four objectives. (1) A questionnaire survey of laboratories was conducted. (2) A standard counting protocol was developed and used by three experienced cytopathologists to determine a reliable and reproducible cell counting method. (3) Slide sets which included a range of cytological abnormalities were each sent to three laboratories for cell counting to study the correlation between cell counts and reported cytological outcomes. (4) Dilution of LBC samples by fluid only (unmixed) or by dilution with a sample containing normal cells (mixed) was performed to study the impact on reporting of reducing either the total cell count or the relative proportion of abnormal to normal cells. The study was conducted within the cervical screening programmes in England, Wales and Scotland, using routinely obtained cervical screening samples, and in 56 participating NHS cervical cytology laboratories. The study involved only routinely obtained cervical screening samples. There was no clinical intervention. The main outcome measures were (1) reliability of counting method, (2) correlation of reported cytology grades with cellularity and (3) levels of detection of abnormal cells in progressively diluted cervical samples. Laboratory practice varied in terms of threshold of cellular adequacy and of morphological markers of adequacy. While SP laboratories generally used a minimum acceptable cell count (MACC) of 15,000, the MACC employed by TP laboratories varied between 5000 and 15,000. The cell counting study showed that a standard protocol achieved moderate to strong inter-rater reproducibility. Analysis of slide reporting from laboratories revealed that a large proportion of the samples reported as inadequate had cell counts above a threshold of 15,000 for SP, and 5000 and 10,000 for TP. Inter-rater unanimity was greater among more cellular preparations. Dilution studies demonstrated greater detection of abnormalities in slides with counts above the MACC and among slides with more than 25 dyskaryotic cells. Variation in laboratory practice demonstrates a requirement for evidence-based standards for designating a MACC. This study has indicated that a MACC of 15,000 and 5000 for SP and TP, respectively, achieves a balance in terms of maintaining sensitivity and low inadequacy rates. The findings of this study should inform the development of laboratory practice guidelines. The National Institute for Health Research Health Technology Assessment programme.
Developing a Measure of Traffic Calming Associated with Elementary School Students’ Active Transport
Nicholson, Lisa M.; Turner, Lindsey; Slater, Sandy J.; Abuzayd, Haytham; Chriqui, Jamie F.; Chaloupka, Frank
2014-01-01
The objective of this study is to develop a measure of traffic calming with nationally available GIS data from NAVTEQ and to validate the traffic calming index with the percentage of children reported by school administrators as walking or biking to school, using data from a nationally representative sample of elementary schools in 2006-2010. Specific models, with and without correlated errors, examined associations of objective GIS measures of the built environment, nationally available from NAVTEQ, with the latent construct of traffic calming. The best fit model for the latent traffic calming construct was determined to be a five factor model including objective measures of intersection density, count of medians/dividers, count of low mobility streets, count of roundabouts, and count of on-street parking availability, with no correlated errors among items. This construct also proved to be a good fit for the full measurement model when the outcome measure of percentage of students walking or biking to school was added to the model. The traffic calming measure was strongly, significantly, and positively correlated with the percentage of students reported as walking or biking to school. Applicability of results to public health and transportation policies and practices are discussed. PMID:25506255
Nicholson, Lisa M; Turner, Lindsey; Slater, Sandy J; Abuzayd, Haytham; Chriqui, Jamie F; Chaloupka, Frank
2014-12-01
The objective of this study is to develop a measure of traffic calming with nationally available GIS data from NAVTEQ and to validate the traffic calming index with the percentage of children reported by school administrators as walking or biking to school, using data from a nationally representative sample of elementary schools in 2006-2010. Specific models, with and without correlated errors, examined associations of objective GIS measures of the built environment, nationally available from NAVTEQ, with the latent construct of traffic calming. The best fit model for the latent traffic calming construct was determined to be a five factor model including objective measures of intersection density, count of medians/dividers, count of low mobility streets, count of roundabouts, and count of on-street parking availability, with no correlated errors among items. This construct also proved to be a good fit for the full measurement model when the outcome measure of percentage of students walking or biking to school was added to the model. The traffic calming measure was strongly, significantly, and positively correlated with the percentage of students reported as walking or biking to school. Applicability of results to public health and transportation policies and practices are discussed.
Abudurexiti, Abulajiang; Kameda, Masashi; Sato, Eiichi; Abderyim, Purkhet; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Takahashi, Kiyomi; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2010-07-01
An energy-discrimination K-edge X-ray computed tomography (CT) system is useful for increasing the contrast resolution of a target region by utilizing contrast media. The CT system has a cadmium telluride (CdTe) detector, and a projection curve is obtained by linear scanning with use of the CdTe detector in conjunction with an X-stage. An object is rotated by a rotation step angle with use of a turntable between the linear scans. Thus, CT is carried out by repetition of the linear scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced with use of charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. For performing energy discrimination, a low-dose-rate X-ray generator for photon counting was developed; the maximum tube voltage and the minimum tube current were 110 kV and 1.0 microA, respectively. In energy-discrimination CT, the tube voltage and the current were 60 kV and 20.0 microA, respectively, and the X-ray intensity was 0.735 microGy/s at 1.0 m from the source and with a tube voltage of 60 kV. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selection of photons with energies just beyond the iodine K-edge energy of 33.2 keV.
Characterization of the 2012-044C Briz-M Upper Stage Breakup
NASA Technical Reports Server (NTRS)
Hamilton, Joseph A.; Matney, Mark
2013-01-01
The NASA breakup model prediction was close to the observed population for catalog objects. The NASA breakup model predicted a larger population than was observed for objects under 10 cm. The stare technique produces low observation counts, but is readily comparable to model predictions. Customized stare parameters (Az, El, Range) were effective to increase the opportunities for HAX to observe the debris cloud. Other techniques to increase observation count will be considered for future breakup events.
Accuracy of a remote quantitative image analysis in the whole slide images.
Słodkowska, Janina; Markiewicz, Tomasz; Grala, Bartłomiej; Kozłowski, Wojciech; Papierz, Wielisław; Pleskacz, Katarzyna; Murawski, Piotr
2011-03-30
The rationale for choosing a remote quantitative method supporting a diagnostic decision requires some empirical studies and knowledge on scenarios including valid telepathology standards. The tumours of the central nervous system [CNS] are graded on the base of the morphological features and the Ki-67 labelling Index [Ki-67 LI]. Various methods have been applied for Ki-67 LI estimation. Recently we have introduced the Computerized Analysis of Medical Images [CAMI] software for an automated Ki-67 LI counting in the digital images. Aims of our study was to explore the accuracy and reliability of a remote assessment of Ki-67 LI with CAMI software applied to the whole slide images [WSI]. The WSI representing CNS tumours: 18 meningiomas and 10 oligodendrogliomas were stored on the server of the Warsaw University of Technology. The digital copies of entire glass slides were created automatically by the Aperio ScanScope CS with objective 20x or 40x. Aperio's Image Scope software provided functionality for a remote viewing of WSI. The Ki-67 LI assessment was carried on within 2 out of 20 selected fields of view (objective 40x) representing the highest labelling areas in each WSI. The Ki-67 LI counting was performed by 3 various methods: 1) the manual reading in the light microscope - LM, 2) the automated counting with CAMI software on the digital images - DI , and 3) the remote quantitation on the WSIs - as WSI method. The quality of WSIs and technical efficiency of the on-line system were analysed. The comparative statistical analysis was performed for the results obtained by 3 methods of Ki-67 LI counting. The preliminary analysis showed that in 18% of WSI the results of Ki-67 LI differed from those obtained in other 2 methods of counting when the quality of the glass slides was below the standard range. The results of our investigations indicate that the remote automated Ki-67 LI analysis performed with the CAMI algorithm on the whole slide images of meningiomas and oligodendrogliomas could be successfully used as an alternative method to the manual reading as well as to the digital images quantitation with CAMI software. According to our observation a need of a remote supervision/consultation and training for the effective use of remote quantitative analysis of WSI is necessary.
NASA Astrophysics Data System (ADS)
Niwase, Hiroaki; Takada, Naoki; Araki, Hiromitsu; Maeda, Yuki; Fujiwara, Masato; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi
2016-09-01
Parallel calculations of large-pixel-count computer-generated holograms (CGHs) are suitable for multiple-graphics processing unit (multi-GPU) cluster systems. However, it is not easy for a multi-GPU cluster system to accomplish fast CGH calculations when CGH transfers between PCs are required. In these cases, the CGH transfer between the PCs becomes a bottleneck. Usually, this problem occurs only in multi-GPU cluster systems with a single spatial light modulator. To overcome this problem, we propose a simple method using the InfiniBand network. The computational speed of the proposed method using 13 GPUs (NVIDIA GeForce GTX TITAN X) was more than 3000 times faster than that of a CPU (Intel Core i7 4770) when the number of three-dimensional (3-D) object points exceeded 20,480. In practice, we achieved ˜40 tera floating point operations per second (TFLOPS) when the number of 3-D object points exceeded 40,960. Our proposed method was able to reconstruct a real-time movie of a 3-D object comprising 95,949 points.
Density estimation in aerial images of large crowds for automatic people counting
NASA Astrophysics Data System (ADS)
Herrmann, Christian; Metzler, Juergen
2013-05-01
Counting people is a common topic in the area of visual surveillance and crowd analysis. While many image-based solutions are designed to count only a few persons at the same time, like pedestrians entering a shop or watching an advertisement, there is hardly any solution for counting large crowds of several hundred persons or more. We addressed this problem previously by designing a semi-automatic system being able to count crowds consisting of hundreds or thousands of people based on aerial images of demonstrations or similar events. This system requires major user interaction to segment the image. Our principle aim is to reduce this manual interaction. To achieve this, we propose a new and automatic system. Besides counting the people in large crowds, the system yields the positions of people allowing a plausibility check by a human operator. In order to automatize the people counting system, we use crowd density estimation. The determination of crowd density is based on several features like edge intensity or spatial frequency. They indicate the density and discriminate between a crowd and other image regions like buildings, bushes or trees. We compare the performance of our automatic system to the previous semi-automatic system and to manual counting in images. By counting a test set of aerial images showing large crowds containing up to 12,000 people, the performance gain of our new system will be measured. By improving our previous system, we will increase the benefit of an image-based solution for counting people in large crowds.
Fries, M; Montavon, S; Spadavecchia, C; Levionnois, O L
2017-03-01
Methods of evaluating locomotor activity can be useful in efforts to quantify behavioural activity in horses objectively. To evaluate whether an accelerometric device would be adequate to quantify locomotor activity and step frequency in horses, and to distinguish between different levels of activity and different gaits. Observational study in an experimental setting. Dual-mode (activity and step count) piezo-electric accelerometric devices were placed at each of 4 locations (head, withers, forelimb and hindlimb) in each of 6 horses performing different controlled activities including grazing, walking at different speeds, trotting and cantering. Both the activity count and step count were recorded and compared by the various activities. Statistical analyses included analysis of variance for repeated measures, receiver operating characteristic curves, Bland-Altman analysis and linear regression. The accelerometric device was able to quantify locomotor activity at each of the 4 locations investigated and to distinguish between gaits and speeds. The activity count recorded by the accelerometer placed on the hindlimb was the most accurate, displaying a clear discrimination between the different levels of activity and a linear correlation to speed. The accelerometer placed on the head was the only one to distinguish specifically grazing behaviour from standing. The accelerometer placed on the withers was unable to differentiate different gaits and activity levels. The step count function measured at the hindlimb was reliable but the count was doubled at the walk. The dual-mode accelerometric device was sufficiently accurate to quantify and compare locomotor activity in horses moving at different speeds and gaits. Positioning the device on the hindlimb allowed for the most accurate results. The step count function can be useful but must be manually corrected, especially at the walk. © 2016 EVJ Ltd.
Pendleton, G.W.; Ralph, C. John; Sauer, John R.; Droege, Sam
1995-01-01
Many factors affect the use of point counts for monitoring bird populations, including sampling strategies, variation in detection rates, and independence of sample points. The most commonly used sampling plans are stratified sampling, cluster sampling, and systematic sampling. Each of these might be most useful for different objectives or field situations. Variation in detection probabilities and lack of independence among sample points can bias estimates and measures of precision. All of these factors should be con-sidered when using point count methods.
Tanada, H; Ikemoto, T; Masutani, R; Tanaka, H; Takubo, T
2014-02-01
In this study, we evaluated the performance of the ADVIA 120 hematology system for cerebrospinal fluid (CSF) assay. Cell counts and leukocyte differentials in CSF were examined with the ADVIA 120 hematology system, while simultaneously confirming an effective hemolysis agent for automated CSF cell counts. The detection limits of both white blood cell (WBC) counts and red blood cell (RBC) counts on the measurement of CSF cell counts by the ADVIA 120 hematology system were superior at 2 cells/μL (10(-6) L). The WBC count was linear up to 9.850 cells/μL, and the RBC count was linear up to approximately 20 000 cells/μL. The intrarun reproducibility indicated good precision. The leukocyte differential of CSF cells, performed by the ADVIA120 hematology system, showed good correlation with the microscopic procedure. The VersaLyse hemolysis solution efficiently lysed the samples without interfering with cell counts and leukocyte differential, even in a sample that included approximately 50 000/μL RBC. These data show the ADVIA 120 hematology system correctly measured the WBC count and leukocyte differential in CSF. The VersaLyse hemolysis solution is considered to be optimal for hemolysis treatment of CSF when measuring cell counts and differentials by the ADVIA 120 hematology system. © 2013 John Wiley & Sons Ltd.
Flexible Method for Inter-object Communication in C++
NASA Technical Reports Server (NTRS)
Curlett, Brian P.; Gould, Jack J.
1994-01-01
A method has been developed for organizing and sharing large amounts of information between objects in C++ code. This method uses a set of object classes to define variables and group them into tables. The variable tables presented here provide a convenient way of defining and cataloging data, as well as a user-friendly input/output system, a standardized set of access functions, mechanisms for ensuring data integrity, methods for interprocessor data transfer, and an interpretive language for programming relationships between parameters. The object-oriented nature of these variable tables enables the use of multiple data types, each with unique attributes and behavior. Because each variable provides its own access methods, redundant table lookup functions can be bypassed, thus decreasing access times while maintaining data integrity. In addition, a method for automatic reference counting was developed to manage memory safely.
Improved segmentation of occluded and adjoining vehicles in traffic surveillance videos
NASA Astrophysics Data System (ADS)
Juneja, Medha; Grover, Priyanka
2013-12-01
Occlusion in image processing refers to concealment of any part of the object or the whole object from view of an observer. Real time videos captured by static cameras on roads often encounter overlapping and hence, occlusion of vehicles. Occlusion in traffic surveillance videos usually occurs when an object which is being tracked is hidden by another object. This makes it difficult for the object detection algorithms to distinguish all the vehicles efficiently. Also morphological operations tend to join the close proximity vehicles resulting in formation of a single bounding box around more than one vehicle. Such problems lead to errors in further video processing, like counting of vehicles in a video. The proposed system brings forward efficient moving object detection and tracking approach to reduce such errors. The paper uses successive frame subtraction technique for detection of moving objects. Further, this paper implements the watershed algorithm to segment the overlapped and adjoining vehicles. The segmentation results have been improved by the use of noise and morphological operations.
Nakamura, Hirotoshi; Ide, Akane; Kudo, Takumi; Nishihara, Eijun; Ito, Mitsuru; Miyauchi, Akira
2016-01-01
Objective Finding agranulocytosis (AG) at an early stage is important to improve outcome, but periodic granulocyte count monitoring is not generally recommended for patients with Graves' disease, because AG develops suddenly. Method At the Kuma Hospital, Graves' patients under antithyroid drug (ATD) treatment in an outpatient clinic have a granulocyte count examination during each visit, and if it is <1,000/μl, a warning is immediately sent to the patient's physician. We evaluated the usefulness of this system. Results We investigated 25 AG and 33 granulocytopenia (GP) cases over a recent 5-year period, excluding patients who developed AG or GP at another hospital and were referred to us for treatment. Among the 25 AG patients, 16 patients (64%; 9 asymptomatic and 7 very mild symptomatic cases) were discovered by the periodic granulocyte count examination at an outpatient clinic. The remaining 9 patients visited the Kuma Hospital or other hospitals because of infection symptoms. Most of the AG patients were given granulocyte colony-stimulating factor injections immediately and were admitted if a prompt increase in granulocytes could not be obtained. The final treatments for Graves' disease were 131I-radioisotope therapy (19 patients), thyroidectomy (2 patients), inorganic iodine (1 patient), or another ATD (1 patient). Among the 33 GP patients, 31 (94%), including 20 asymptomatic cases, were discovered during periodic granulocyte count monitoring. Most of them stopped ATD, and other treatments for Graves' disease were selected. Conclusion Periodic monitoring of granulocyte counts is useful for identifying AG and GP patients with no or minimum infection symptoms. PMID:28101490
Rocket instrument for far-UV spectrophotometry of faint astronomical objects.
Hartig, G F; Fastie, W G; Davidsen, A F
1980-03-01
A sensitive sounding rocket instrument for moderate (~10-A) resolution far-UV (lambda1160-lambda1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employs a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.
Melon yield prediction using small unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Zhao, Tiebiao; Wang, Zhongdao; Yang, Qi; Chen, YangQuan
2017-05-01
Thanks to the development of camera technologies, small unmanned aerial systems (sUAS), it is possible to collect aerial images of field with more flexible visit, higher resolution and much lower cost. Furthermore, the performance of objection detection based on deeply trained convolutional neural networks (CNNs) has been improved significantly. In this study, we applied these technologies in the melon production, where high-resolution aerial images were used to count melons in the field and predict the yield. CNN-based object detection framework-Faster R-CNN is applied in the melon classification. Our results showed that sUAS plus CNNs were able to detect melons accurately in the late harvest season.
A Wireless Sensor Network-Based Portable Vehicle Detector Evaluation System
Yoo, Seong-eun
2013-01-01
In an upcoming smart transportation environment, performance evaluations of existing Vehicle Detection Systems are crucial to maintain their accuracy. The existing evaluation method for Vehicle Detection Systems is based on a wired Vehicle Detection System reference and a video recorder, which must be operated and analyzed by capable traffic experts. However, this conventional evaluation system has many disadvantages. It is inconvenient to deploy, the evaluation takes a long time, and it lacks scalability and objectivity. To improve the evaluation procedure, this paper proposes a Portable Vehicle Detector Evaluation System based on wireless sensor networks. We describe both the architecture and design of a Vehicle Detector Evaluation System and the implementation results, focusing on the wireless sensor networks and methods for traffic information measurement. With the help of wireless sensor networks and automated analysis, our Vehicle Detector Evaluation System can evaluate a Vehicle Detection System conveniently and objectively. The extensive evaluations of our Vehicle Detector Evaluation System show that it can measure the traffic information such as volume counts and speed with over 98% accuracy. PMID:23344388
A wireless sensor network-based portable vehicle detector evaluation system.
Yoo, Seong-eun
2013-01-17
In an upcoming smart transportation environment, performance evaluations of existing Vehicle Detection Systems are crucial to maintain their accuracy. The existing evaluation method for Vehicle Detection Systems is based on a wired Vehicle Detection System reference and a video recorder, which must be operated and analyzed by capable traffic experts. However, this conventional evaluation system has many disadvantages. It is inconvenient to deploy, the evaluation takes a long time, and it lacks scalability and objectivity. To improve the evaluation procedure, this paper proposes a Portable Vehicle Detector Evaluation System based on wireless sensor networks. We describe both the architecture and design of a Vehicle Detector Evaluation System and the implementation results, focusing on the wireless sensor networks and methods for traffic information measurement. With the help of wireless sensor networks and automated analysis, our Vehicle Detector Evaluation System can evaluate a Vehicle Detection System conveniently and objectively. The extensive evaluations of our Vehicle Detector Evaluation System show that it can measure the traffic information such as volume counts and speed with over 98% accuracy.
OpenCFU, a new free and open-source software to count cell colonies and other circular objects.
Geissmann, Quentin
2013-01-01
Counting circular objects such as cell colonies is an important source of information for biologists. Although this task is often time-consuming and subjective, it is still predominantly performed manually. The aim of the present work is to provide a new tool to enumerate circular objects from digital pictures and video streams. Here, I demonstrate that the created program, OpenCFU, is very robust, accurate and fast. In addition, it provides control over the processing parameters and is implemented in an intuitive and modern interface. OpenCFU is a cross-platform and open-source software freely available at http://opencfu.sourceforge.net.
A high dynamic range pulse counting detection system for mass spectrometry.
Collings, Bruce A; Dima, Martian D; Ivosev, Gordana; Zhong, Feng
2014-01-30
A high dynamic range pulse counting system has been developed that demonstrates an ability to operate at up to 2e8 counts per second (cps) on a triple quadrupole mass spectrometer. Previous pulse counting detection systems have typically been limited to about 1e7 cps at the upper end of the systems dynamic range. Modifications to the detection electronics and dead time correction algorithm are described in this paper. A high gain transimpedance amplifier is employed that allows a multi-channel electron multiplier to be operated at a significantly lower bias potential than in previous pulse counting systems. The system utilises a high-energy conversion dynode, a multi-channel electron multiplier, a high gain transimpedance amplifier, non-paralysing detection electronics and a modified dead time correction algorithm. Modification of the dead time correction algorithm is necessary due to a characteristic of the pulse counting electronics. A pulse counting detection system with the capability to count at ion arrival rates of up to 2e8 cps is described. This is shown to provide a linear dynamic range of nearly five orders of magnitude for a sample of aprazolam with concentrations ranging from 0.0006970 ng/mL to 3333 ng/mL while monitoring the m/z 309.1 → m/z 205.2 transition. This represents an upward extension of the detector's linear dynamic range of about two orders of magnitude. A new high dynamic range pulse counting system has been developed demonstrating the ability to operate at up to 2e8 cps on a triple quadrupole mass spectrometer. This provides an upward extension of the detector's linear dynamic range by about two orders of magnitude over previous pulse counting systems. Copyright © 2013 John Wiley & Sons, Ltd.
Neural representation of objects in space: a dual coding account.
Humphreys, G W
1998-01-01
I present evidence on the nature of object coding in the brain and discuss the implications of this coding for models of visual selective attention. Neuropsychological studies of task-based constraints on: (i) visual neglect; and (ii) reading and counting, reveal the existence of parallel forms of spatial representation for objects: within-object representations, where elements are coded as parts of objects, and between-object representations, where elements are coded as independent objects. Aside from these spatial codes for objects, however, the coding of visual space is limited. We are extremely poor at remembering small spatial displacements across eye movements, indicating (at best) impoverished coding of spatial position per se. Also, effects of element separation on spatial extinction can be eliminated by filling the space with an occluding object, indicating that spatial effects on visual selection are moderated by object coding. Overall, there are separate limits on visual processing reflecting: (i) the competition to code parts within objects; (ii) the small number of independent objects that can be coded in parallel; and (iii) task-based selection of whether within- or between-object codes determine behaviour. Between-object coding may be linked to the dorsal visual system while parallel coding of parts within objects takes place in the ventral system, although there may additionally be some dorsal involvement either when attention must be shifted within objects or when explicit spatial coding of parts is necessary for object identification. PMID:9770227
Abstract numerical discrimination learning in rats.
Taniuchi, Tohru; Sugihara, Junko; Wakashima, Mariko; Kamijo, Makiko
2016-06-01
In this study, we examined rats' discrimination learning of the numerical ordering positions of objects. In Experiments 1 and 2, five out of seven rats successfully learned to respond to the third of six identical objects in a row and showed reliable transfer of this discrimination to novel stimuli after being trained with three different training stimuli. In Experiment 3, the three rats from Experiment 2 continued to be trained to respond to the third object in an object array, which included an odd object that needed to be excluded when identifying the target third object. All three rats acquired this selective-counting task of specific stimuli, and two rats showed reliable transfer of this selective-counting performance to test sets of novel stimuli. In Experiment 4, the three rats from Experiment 3 quickly learned to respond to the third stimulus in object rows consisting of either six identical or six different objects. These results offer strong evidence for abstract numerical discrimination learning in rats.
High-sensitive computed tomography system using a silicon-PIN x-ray diode
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Sato, Yuich; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2012-10-01
A low-dose-rate X-ray computed tomography (CT) system is useful for reducing absorbed dose for patients. The CT system with a tube current of 1.91 mA was developed using a silicon-PIN X-ray diode (Si-PIN-XD). The Si-PIN-XD is a selected high-sensitive Si-PIN photodiode (PD) for detecting X-ray photons. X-ray photons are detected directly using the Si-PIN-XD without a scintillator, and the photocurrent from the diode is amplified using current-voltage and voltage-voltage amplifiers. The output voltage is converted into logical pulses using a voltage-frequency converter with maximum frequency of 500 kHz, and the frequency is proportional to the voltage. The pulses from the converter are sent to differentiator with a time constant of 1 μs to generate short positive pulses for counting, and the pulses are counted using a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The exposure time for obtaining a tomogram was 5 min at a scan step of 0.5 mm and a rotation step of 3.0°. The tube current and voltage were 1.91 mA and 100 kV, respectively, and gadolinium K-edge CT was carried out using filtered X-ray spectra with a peak energy of 52 keV.
Hontelez, Jan A.C.; Chang, Angela Y.; Ogbuoji, Osondu; de Vlas, Sake J.; Bärnighausen, Till; Atun, Rifat
2016-01-01
Objective: We estimated the investment needs, population health gains, and cost-effectiveness of different policy options for scaling-up prevention and treatment of HIV in the 10 countries that currently comprise 80% of all people living with HIV in sub-Saharan Africa (Ethiopia, Kenya, Malawi, Mozambique, Nigeria, South Africa, Tanzania, Uganda, Zambia, and Zimbabwe). Design: We adapted the established STDSIM model to capture the health system dynamics: demand-side and supply-side constraints in the delivery of antiretroviral treatment (ART). Methods: We compared different scenarios of supply-side (i.e. health system capacity) and demand-side (i.e. health seeking behavior) constraints, and determined the impact of changing guidelines to ART eligibility at any CD4+ cell count within these constraints. Results: Continuing current scale-up would require US$178 billion by 2050. Changing guidelines to ART at any CD4+ cell count is cost-effective under all constraints tested in the model, especially in demand-side constrained health systems because earlier initiation prevents loss-to-follow-up of patients not yet eligible. Changing guidelines under current demand-side constraints would avert 1.8 million infections at US$208 per life-year saved. Conclusion: Treatment eligibility at any CD4+ cell count would be cost-effective, even under health system constraints. Excessive loss-to-follow-up and mortality in patients not eligible for treatment can be avoided by changing guidelines in demand-side constrained systems. The financial obligation for sustaining the AIDS response in sub-Saharan Africa over the next 35 years is substantial and requires strong, long-term commitment of policy-makers and donors to continue to allocate substantial parts of their budgets. PMID:27367487
DOT National Transportation Integrated Search
2009-01-01
The objective of this project was to develop an improved correlation between Texas Cone Penetrometer (TCP) : blow count and undrained shear strength for soft, clay soils in the upper approximately 30 feet of the ground. Subsurface : explorations were...
NASA Astrophysics Data System (ADS)
Lehmann, I.; Scholz, R.-D.
1997-04-01
We present new tidal radii for seven Galactic globular clusters using the method of automated star counts on Schmidt plates of the Tautenburg, Palomar and UK telescopes. The plates were fully scanned with the APM system in Cambridge (UK). Special account was given to a reliable background subtraction and the correction of crowding effects in the central cluster region. For the latter we used a new kind of crowding correction based on a statistical approach to the distribution of stellar images and the luminosity function of the cluster stars in the uncrowded area. The star counts were correlated with surface brightness profiles of different authors to obtain complete projected density profiles of the globular clusters. Fitting an empirical density law (King 1962) we derived the following structural parameters: tidal radius r_t_, core radius r_c_ and concentration parameter c. In the cases of NGC 5466, M 5, M 12, M 13 and M 15 we found an indication for a tidal tail around these objects (cf. Grillmair et al. 1995).
Seroprevalence of Brucellosis in Human Immunodeficiency Virus Infected Patients in Hamadan, Iran
Keramat, Fariba; Majzobi, Mohammad Mehdi; Poorolajal, Jalal; Ghane, Zohreh Zarei; Adabi, Maryam
2017-01-01
Objectives Brucellosis is a systemic disease with a wide spectrum of clinical manifestations. This study aimed to determine the seroprevalence of brucellosis in human immunodeficiency virus (HIV) infected patients in Hamadan Province in the west of Iran. Methods A total of 157 HIV-infected patients were screened through standard serological tests, including Wright’s test, Coombs’ Wright test, and 2-mercaptoethanol Brucella agglutination test (2ME test), blood cultures in Castaneda media, and CD4 counting. Data were analyzed using Stata version 11. Results Wright and Coombs’ Wright tests were carried out, and only 5 (3.2%) patients had positive serological results. However, all patients had negative 2ME results, and blood cultures were negative for Brucella spp. Moreover, patients with positive serology and a mean CD4 count of 355.8 ± 203.11 cells/μL had no clinical manifestations of brucellosis, and, and the other patients had a mean CD4 count of 335.55 ± 261.71 cells/μL. Conclusion Results of this study showed that HIV infection is not a predisposing factor of acquiring brucellosis. PMID:28904852
Development of a Photon Counting System for Differential Lidar Signal Detection
NASA Technical Reports Server (NTRS)
Elsayed-Ali, Hani
1997-01-01
Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.
Hart, Teresa L; Brusseau, Timothy; Kulinna, Pamela Hodges; McClain, James J; Tudor-Locke, Catrine
2011-12-01
This study compared step counts detected by four, low-cost, objective, physical-activity-assessment instruments and evaluated their ability to detect moderate-to-vigorous physical activity (MVPA) compared to the ActiGraph accelerometer (AG). Thirty-six 10-11-year-old children wore the NL-1000, Yamax Digiwalker SW 200, Omron HJ-151, and Walk4Life MVP concurrently with the AG during school hours on a single day. AG MVPA was derived from activity count data using previously validated cut points. Two of the evaluated instruments provided similar group mean MVPA and step counts compared to AG (dependent on cut point). Low-cost instruments may be useful for measurement of both MVPA and steps in children's physical activity interventions and program evaluation.
Fukushima, Tsuyoshi; Annen, Kazuya; Kawamukai, Yuji; Onuma, Noritomo; Kawashima, Mayu
2014-07-01
We investigated whether objective evaluation by using the palliative prognostic index(PPI), controlling nutritional status(COUNT), and prognostic nutritional index(PNI)can provide prognostic information during the transition from chemotherapy to palliative care in patients with advanced or recurrent gastrointestinal cancer. The subjects were 28 patients with gastrointestinal cancer who died of their disease between January 2009 and June 2012. We compared the PPI, COUNT, and PNI scores between patients who died within 90 days of completing chemotherapy(Group A, n=14)and patients who survived for 90 or more days(Group B, n=14). The PPI score for Group A(4.0)was significantly higher than that for Group B(0.8)(p<0.001). The COUNT score was also significantly higher for Group A(6.3)than for Group B (3.9)(p=0.033). A significant difference in survival was evident when the cutoff value for PNI was set at 40 in the critical region(68/118, p=0.04). Our study suggests that the PPI, COUNT, and PNI may be useful for objective evaluation during the transition from chemotherapy to palliative care.
Estimating the vegetation canopy height using micro-pulse photon-counting LiDAR data.
Nie, Sheng; Wang, Cheng; Xi, Xiaohuan; Luo, Shezhou; Li, Guoyuan; Tian, Jinyan; Wang, Hongtao
2018-05-14
The upcoming space-borne LiDAR satellite Ice, Cloud and land Elevation Satellite-2 (ICESat-2) is scheduled to launch in 2018. Different from the waveform LiDAR system onboard the ICESat, ICESat-2 will use a micro-pulse photon-counting LiDAR system. Thus new data processing algorithms are required to retrieve vegetation canopy height from photon-counting LiDAR data. The objective of this paper is to develop and validate an automated approach for better estimating vegetation canopy height. The new proposed method consists of three key steps: 1) filtering out the noise photons by an effective noise removal algorithm based on localized statistical analysis; 2) separating ground returns from canopy returns using an iterative photon classification algorithm, and then determining ground surface; 3) generating canopy-top surface and calculating vegetation canopy height based on canopy-top and ground surfaces. This automatic vegetation height estimation approach was tested to the simulated ICESat-2 data produced from Sigma Space LiDAR data and Multiple Altimeter Beam Experimental LiDAR (MABEL) data, and the retrieved vegetation canopy heights were validated by canopy height models (CHMs) derived from airborne discrete-return LiDAR data. Results indicated that the estimated vegetation canopy heights have a relatively strong correlation with the reference vegetation heights derived from airborne discrete-return LiDAR data (R 2 and RMSE values ranging from 0.639 to 0.810 and 4.08 m to 4.56 m respectively). This means our new proposed approach is appropriate for retrieving vegetation canopy height from micro-pulse photon-counting LiDAR data.
McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S
2014-03-01
A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.
An automated approach for annual layer counting in ice cores
NASA Astrophysics Data System (ADS)
Winstrup, M.; Svensson, A.; Rasmussen, S. O.; Winther, O.; Steig, E.; Axelrod, A.
2012-04-01
The temporal resolution of some ice cores is sufficient to preserve seasonal information in the ice core record. In such cases, annual layer counting represents one of the most accurate methods to produce a chronology for the core. Yet, manual layer counting is a tedious and sometimes ambiguous job. As reliable layer recognition becomes more difficult, a manual approach increasingly relies on human interpretation of the available data. Thus, much may be gained by an automated and therefore objective approach for annual layer identification in ice cores. We have developed a novel method for automated annual layer counting in ice cores, which relies on Bayesian statistics. It uses algorithms from the statistical framework of Hidden Markov Models (HMM), originally developed for use in machine speech recognition. The strength of this layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on purely objective criteria for annual layer identification. With this methodology, it is possible to determine the most likely position of multiple layer boundaries in an entire section of ice core data at once. It provides a probabilistic uncertainty estimate of the resulting layer count, hence ensuring a proper treatment of ambiguous layer boundaries in the data. Furthermore multiple data series can be incorporated to be used at once, hence allowing for a full multi-parameter annual layer counting method similar to a manual approach. In this study, the automated layer counting algorithm has been applied to data from the NGRIP ice core, Greenland. The NGRIP ice core has very high temporal resolution with depth, and hence the potential to be dated by annual layer counting far back in time. In previous studies [Andersen et al., 2006; Svensson et al., 2008], manual layer counting has been carried out back to 60 kyr BP. A comparison between the counted annual layers based on the two approaches will be presented and their differences discussed. Within the estimated uncertainties, the two methodologies agree. This shows the potential for a fully automated annual layer counting method to be operational for data sections where the annual layering is unknown.
Palta, Mari; Sadek-Badawi, Mona; Carlton, David P
2008-01-01
Objectives To investigate associations between early low neutrophil count from routine blood samples, white blood count (WBC), pregnancy complications and neonatal outcomes for very low birth weight infants (VLBW ≤1500g) with gestational age <32 weeks. Patients and Methods Information was abstracted on all infants admitted to level III NICUs in Wisconsin 2003-2004. 1002 (78%) had differential and corrected total white counts within 2 ½ hours of birth. Data analyses included frequency tables, binary logistic, ordinal logistc and ordinary regression. Results Low neutrophil count (<1000/μL) was strongly associated with low WBC, pregnancy complications and antenatal steroids. Low neutrophil count predicted bronchopulmonary dysplasia severity level (BPD) (OR: 1.7, 95% CI: 1.1-2.7) and intraventricular hemorrhage (IVH) grade (OR: 2.2, 95% CI: 1.3-3.8). Conclusions Early neutrophil counts may have multiple causes interfering with their routine use as an inflammatory marker. Nonetheless, low neutrophil count has consistent independent associations with outcomes. PMID:18563166
HgCdTe APD-based linear-mode photon counting components and ladar receivers
NASA Astrophysics Data System (ADS)
Jack, Michael; Wehner, Justin; Edwards, John; Chapman, George; Hall, Donald N. B.; Jacobson, Shane M.
2011-05-01
Linear mode photon counting (LMPC) provides significant advantages in comparison with Geiger Mode (GM) Photon Counting including absence of after-pulsing, nanosecond pulse to pulse temporal resolution and robust operation in the present of high density obscurants or variable reflectivity objects. For this reason Raytheon has developed and previously reported on unique linear mode photon counting components and modules based on combining advanced APDs and advanced high gain circuits. By using HgCdTe APDs we enable Poisson number preserving photon counting. A metric of photon counting technology is dark count rate and detection probability. In this paper we report on a performance breakthrough resulting from improvement in design, process and readout operation enabling >10x reduction in dark counts rate to ~10,000 cps and >104x reduction in surface dark current enabling long 10 ms integration times. Our analysis of key dark current contributors suggest that substantial further reduction in DCR to ~ 1/sec or less can be achieved by optimizing wavelength, operating voltage and temperature.
Choudhry, Priya
2016-01-01
Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849
Toward Advancing Nano-Object Count Metrology: A Best Practice Framework
Boyko, Volodymyr; Meyers, Greg; Voetz, Matthias; Wohlleben, Wendel
2013-01-01
Background: A movement among international agencies and policy makers to classify industrial materials by their number content of sub–100-nm particles could have broad implications for the development of sustainable nanotechnologies. Objectives: Here we highlight current particle size metrology challenges faced by the chemical industry due to these emerging number percent content thresholds, provide a suggested best-practice framework for nano-object identification, and identify research needs as a path forward. Discussion: Harmonized methods for identifying nanomaterials by size and count for many real-world samples do not currently exist. Although particle size remains the sole discriminating factor for classifying a material as “nano,” inconsistencies in size metrology will continue to confound policy and decision making. Moreover, there are concerns that the casting of a wide net with still-unproven metrology methods may stifle the development and judicious implementation of sustainable nanotechnologies. Based on the current state of the art, we propose a tiered approach for evaluating materials. To enable future risk-based refinements of these emerging definitions, we recommend that this framework also be considered in environmental and human health research involving the implications of nanomaterials. Conclusion: Substantial scientific scrutiny is needed in the area of nanomaterial metrology to establish best practices and to develop suitable methods before implementing definitions based solely on number percent nano-object content for regulatory purposes. Strong cooperation between industry, academia, and research institutions will be required to fully develop and implement detailed frameworks for nanomaterial identification with respect to emerging count-based metrics. Citation: Brown SC, Boyko V, Meyers G, Voetz M, Wohlleben W. 2013. Toward advancing nano-object count metrology: a best practice framework. Environ Health Perspect 121:1282–1291; http://dx.doi.org/10.1289/ehp.1306957 PMID:24076973
Energy-discriminating X-ray computed tomography system utilizing a cadmium telluride detector
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Abderyim, Purkhet; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Takahasi, Kiyomi; Sato, Shigehiro; Ogawae, Akira; Onagawa, Jun
2010-07-01
An energy-discriminating K-edge X-ray computed tomography (CT) system is useful for increasing contrast resolution of a target region utilizing contrast media and for reducing the absorbed dose for patients. The CT system is of the first-generation type with a cadmium telluride (CdTe) detector, and a projection curve is obtained by translation scanning using the CdTe detector in conjunction with an x-stage. An object is rotated by the rotation step angle using a turntable between the translation scans. Thus, CT is carried out by repeating the translation scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced using charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selecting photons with energies just beyond the iodine K-edge energy of 33.2 keV.
NASA Astrophysics Data System (ADS)
Nyarko, B. J. B.; Bredwa-Mensah, Y.; Serfor-Armah, Y.; Dampare, S. B.; Akaho, E. H. K.; Osae, S.; Perbi, A.; Chatt, A.
2007-10-01
Concentrations of trace elements in ancient pottery excavated from Jenini in the Brong Ahafo region of Ghana were determined using instrumental neutron activation analysis (INAA) in conjunction with both conventional and Compton suppression counting. Jenini was a slave Camp of Samory Toure during the indigenous slavery and the Trans-Atlantic slave trade. Pottery fragments found during the excavation of the grave tombs of the slaves who died in the slave camps were analysed. In all, 26 trace elements were determined in 40 pottery fragments. These elemental concentrations were processed using multivariate statistical methods, cluster, factor and discriminant analyses in order to determine similarities and correlation between the various samples. The suitability of the two counting systems for determination of trace elements in pottery objects has been evaluated.
OpenCFU, a New Free and Open-Source Software to Count Cell Colonies and Other Circular Objects
Geissmann, Quentin
2013-01-01
Counting circular objects such as cell colonies is an important source of information for biologists. Although this task is often time-consuming and subjective, it is still predominantly performed manually. The aim of the present work is to provide a new tool to enumerate circular objects from digital pictures and video streams. Here, I demonstrate that the created program, OpenCFU, is very robust, accurate and fast. In addition, it provides control over the processing parameters and is implemented in an intuitive and modern interface. OpenCFU is a cross-platform and open-source software freely available at http://opencfu.sourceforge.net. PMID:23457446
New generation of telemetry systems using CCSDS packetisation - A prototype implementation
NASA Astrophysics Data System (ADS)
Sotta, J. P.; Held, K.
1988-07-01
The system described herein was developed under ESA contract to support the introduction of new telemetry standards based on the packetized telemetry data concept. These standards were derived from recommendations in the frame of work of CCSDS, an inter-Agency committee that counts among its members most European National Agencies, ESA, NASA as well as Japanese NASDA, Indian ISRO and Brazilian INPE and having as objective to facilitate cross-support for space missions. The development is based on the present generation of ESA on-board equipment (OBDH) subsystem and is fully compatible with OBDH bus interfaces and transfer protocol.
Prophylactic platelet transfusions prior to surgery for people with a low platelet count
Estcourt, Lise J; Malouf, Reem; Doree, Carolyn; Trivella, Marialena; Hopewell, Sally; Birchall, Janet
2017-01-01
This is a protocol for a Cochrane Review (Intervention). The objectives are as follows: To determine the clinical effectiveness and safety of prophylactic platelet transfusions prior to surgery for people with a low platelet count or platelet dysfunction (inherited or acquired). PMID:29151812
Genetic parameters for fecal egg count and body weight in Katahdin lambs
USDA-ARS?s Scientific Manuscript database
The objective of this study was to estimate genetic parameters for fecal egg count at weaning (WFEC) and post weaning (PWFEC), and weights at birth (BW), weaning (WW) and post weaning (PWW) in Katahdin lambs by investigating direct additive, maternal additive, maternal permanent environmental and ma...
Assessment of Differing Definitions of Accelerometer Nonwear Time
ERIC Educational Resources Information Center
Evenson, Kelly R.; Terry, James W., Jr.
2009-01-01
Measuring physical activity with objective tools, such as accelerometers, is becoming more common. Accelerometers measure acceleration multiple times within a given frequency and summarize this as a count over a pre-specified time period or epoch. The resultant count represents acceleration over the epoch length. Accelerometers eliminate biases…
Counting supersymmetric branes
NASA Astrophysics Data System (ADS)
Kleinschmidt, Axel
2011-10-01
Maximal supergravity solutions are revisited and classified, with particular emphasis on objects of co-dimension at most two. This class of solutions includes branes whose tension scales with xxxx. We present a group theory derivation of the counting of these objects based on the corresponding tensor hierarchies derived from E 11 and discrete T- and U-duality transformations. This provides a rationale for the wrapping rules that were recently discussed for σ ≤ 3 in the literature and extends them. Explicit supergravity solutions that give rise to co-dimension two branes are constructed and analysed.
Costagliola, Dominique; Lacombe, Jean-Marc; Ghosn, Jade; Delaugerre, Constance; Pialoux, Gilles; Cuzin, Lise; Launay, Odile; Ménard, Amélie; de Truchis, Pierre; Mary-Krause, Murielle; Weiss, Laurence; Delfraissy, Jean-François
2014-01-01
A key objective of combined antiretroviral therapy (cART) is to reach and maintain high CD4 cell counts to provide long-term protection against AIDS-defining opportunistic infections and malignancies, as well as other comorbidities. However, a high proportion of patients present late for care. Our objective was to assess CD4 cell count recovery up to seven years in naïve patients initiating cART with at least three drugs in usual clinical care. From the French Hospital Database on HIV, we selected naïve individuals initiating cART from 2000 with at least two years of follow-up. Participants were further required to have achieved viral load suppression by six months after initiating cART and were censored in case of virological failure. We calculated the proportion of patients (Kaplan-Meier estimates) who achieved CD4 recovery to >500/mm(3) according to baseline CD4 cell count. A total of 15,025 patients were analyzed with a median follow-up on ART of 65.5 months (IQR: 42.3-96.0). At cART initiation, the median age was 38.6 years (IQR: 32.2-46.0), 9734 (64.8%) were men, median CD4 cell count was 239 (IQR: 130-336) and 2668 (17.8%) had a prior AIDS event. RESULTS are presented in the Table 1. This study shows that CD4 cell counts continue to increase seven years after cART initiation, whatever the baseline CD4 cell count. Failing to achieve CD4 recovery with continuous viral load suppression is rare for naïve patients initiating cART in routine clinical practice, but takes substantially longer in patients who initiate antiretroviral therapy at low CD4 cell counts.
Registration system for 71Ge rare decays in proportional counters for BEST experiment
NASA Astrophysics Data System (ADS)
Gavrin, V. N.; Gorbachev, V. V.; Ibragimova, T. V.; Kalikhov, A. V.; Shikhin, A. A.; Yants, V. E.
2018-01-01
New counting system for 71Ge decays rare events registration is developed for realization of the BEST experiment to search for sterile neutrinos. Description of the system, its technical and counting data are presented in the article. Comparison with already existing counting system for SAGE is given also.
Study of photon correlation techniques for processing of laser velocimeter signals
NASA Technical Reports Server (NTRS)
Mayo, W. T., Jr.
1977-01-01
The objective was to provide the theory and a system design for a new type of photon counting processor for low level dual scatter laser velocimeter (LV) signals which would be capable of both the first order measurements of mean flow and turbulence intensity and also the second order time statistics: cross correlation auto correlation, and related spectra. A general Poisson process model for low level LV signals and noise which is valid from the photon-resolved regime all the way to the limiting case of nonstationary Gaussian noise was used. Computer simulation algorithms and higher order statistical moment analysis of Poisson processes were derived and applied to the analysis of photon correlation techniques. A system design using a unique dual correlate and subtract frequency discriminator technique is postulated and analyzed. Expectation analysis indicates that the objective measurements are feasible.
NASA Astrophysics Data System (ADS)
Adi, K.; Widodo, A. P.; Widodo, C. E.; Pamungkas, A.; Putranto, A. B.
2018-05-01
Traffic monitoring on road needs to be done, the counting of the number of vehicles passing the road is necessary. It is more emphasized for highway transportation management in order to prevent efforts. Therefore, it is necessary to develop a system that is able to counting the number of vehicles automatically. Video processing method is able to counting the number of vehicles automatically. This research has development a system of vehicle counting on toll road. This system includes processes of video acquisition, frame extraction, and image processing for each frame. Video acquisition is conducted in the morning, at noon, in the afternoon, and in the evening. This system employs of background subtraction and morphology methods on gray scale images for vehicle counting. The best vehicle counting results were obtained in the morning with a counting accuracy of 86.36 %, whereas the lowest accuracy was in the evening, at 21.43 %. Differences in morning and evening results are caused by different illumination in the morning and evening. This will cause the values in the image pixels to be different.
Predicting U.S. tuberculosis case counts through 2020.
Woodruff, Rachel S Y E L K; Winston, Carla A; Miramontes, Roque
2013-01-01
In 2010, foreign-born persons accounted for 60% of all tuberculosis (TB) cases in the United States. Understanding which national groups make up the highest proportion of TB cases will assist TB control programs in concentrating limited resources where they can provide the greatest impact on preventing transmission of TB disease. The objective of our study was to predict through 2020 the numbers of U.S. TB cases among U.S.-born, foreign-born and foreign-born persons from selected countries of birth. TB case counts reported through the National Tuberculosis Surveillance System from 2000-2010 were log-transformed, and linear regression was performed to calculate predicted annual case counts and 95% prediction intervals for 2011-2020. Data were analyzed in 2011 before 2011 case counts were known. Decreases were predicted between 2010 observed and 2020 predicted counts for total TB cases (11,182 to 8,117 [95% prediction interval 7,262-9,073]) as well as TB cases among foreign-born persons from Mexico (1,541 to 1,420 [1,066-1,892]), the Philippines (740 to 724 [569-922]), India (578 to 553 [455-672]), Vietnam (532 to 429 [367-502]) and China (364 to 328 [249-433]). TB cases among persons who are U.S.-born and foreign-born were predicted to decline 47% (4,393 to 2,338 [2,113-2,586]) and 6% (6,720 to 6,343 [5,382-7,476]), respectively. Assuming rates of declines observed from 2000-2010 continue until 2020, a widening gap between the numbers of U.S.-born and foreign-born TB cases was predicted. TB case count predictions will help TB control programs identify needs for cultural competency, such as languages and interpreters needed for translating materials or engaging in appropriate community outreach.
A computerized recognition system for the home-based physiotherapy exercises using an RGBD camera.
Ar, Ilktan; Akgul, Yusuf Sinan
2014-11-01
Computerized recognition of the home based physiotherapy exercises has many benefits and it has attracted considerable interest among the computer vision community. However, most methods in the literature view this task as a special case of motion recognition. In contrast, we propose to employ the three main components of a physiotherapy exercise (the motion patterns, the stance knowledge, and the exercise object) as different recognition tasks and embed them separately into the recognition system. The low level information about each component is gathered using machine learning methods. Then, we use a generative Bayesian network to recognize the exercise types by combining the information from these sources at an abstract level, which takes the advantage of domain knowledge for a more robust system. Finally, a novel postprocessing step is employed to estimate the exercise repetitions counts. The performance evaluation of the system is conducted with a new dataset which contains RGB (red, green, and blue) and depth videos of home-based exercise sessions for commonly applied shoulder and knee exercises. The proposed system works without any body-part segmentation, bodypart tracking, joint detection, and temporal segmentation methods. In the end, favorable exercise recognition rates and encouraging results on the estimation of repetition counts are obtained.
DOT National Transportation Integrated Search
1983-05-01
The mechanics of automated passenger counting on transit buses and the accuracy of these systems are discussed. Count data needs to be time coded and distance/location information is necessary for effectively correlating data to specific bus stops or...
Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota
2017-11-25
Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. On five of the seven models, the inter-class correlations coefficient (ICC (3,1) ) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1) : 0.992-0.998. The false detection rates differed between the sitting conditions. These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation.
Hubble Space Telescope faint object camera instrument handbook (Post-COSTAR), version 5.0
NASA Technical Reports Server (NTRS)
Nota, A. (Editor); Jedrzejewski, R. (Editor); Greenfield, P. (Editor); Hack, W. (Editor)
1994-01-01
The faint object camera (FOC) is a long-focal-ratio, photon-counting device capable of taking high-resolution two-dimensional images of the sky up to 14 by 14 arc seconds squared in size with pixel dimensions as small as 0.014 by 0.014 arc seconds squared in the 1150 to 6500 A wavelength range. Its performance approaches that of an ideal imaging system at low light levels. The FOC is the only instrument on board the Hubble Space Telescope (HST) to fully use the spatial resolution capabilities of the optical telescope assembly (OTA) and is one of the European Space Agency's contributions to the HST program.
Fonseca, T C Ferreira; Bogaerts, R; Lebacq, A L; Mihailescu, C L; Vanhavere, F
2014-04-01
A realistic computational 3D human body library, called MaMP and FeMP (Male and Female Mesh Phantoms), based on polygonal mesh surface geometry, has been created to be used for numerical calibration of the whole body counter (WBC) system of the nuclear power plant (NPP) in Doel, Belgium. The main objective was to create flexible computational models varying in gender, body height, and mass for studying the morphology-induced variation of the detector counting efficiency (CE) and reducing the measurement uncertainties. First, the counting room and an HPGe detector were modeled using MCNPX (Monte Carlo radiation transport code). The validation of the model was carried out for different sample-detector geometries with point sources and a physical phantom. Second, CE values were calculated for a total of 36 different mesh phantoms in a seated position using the validated Monte Carlo model. This paper reports on the validation process of the in vivo whole body system and the CE calculated for different body heights and weights. The results reveal that the CE is strongly dependent on the individual body shape, size, and gender and may vary by a factor of 1.5 to 3 depending on the morphology aspects of the individual to be measured.
The work of Glendon Lean on the counting systems of Papua New Guinea and Oceania
NASA Astrophysics Data System (ADS)
Owens, Kay
2001-04-01
Glendon Lean collated data on nearly 900 counting systems of Papua New Guinea, Oceania, and Irian Jaya (West Papua). Lean's data came from a questionnaire completed by students and talks with village elders. He read old documents written in English, German, and Dutch. He made comparisons between older and new accounts of the counting systems and compared neighbouring counting systems from both Austronesian and non-Austronesian languages. His work drew attention to the rich diversity of the systems and suggested that systems based on body parts and cyclic systems developed spontaneously. Digit tally systems were also relatively common. Lean's thesis on spontaneous developments of these ancient cultures challenged traditional theories describing the spread of number systems from Middle East cultures.
Ta, Yen T; Nguyen, Trung Thanh; To, Phuong Bich; Pham, Da Xuan; Le, Hao Thi Hong; Thi, Giang Nguyen; Alali, Walid Q; Walls, Isabel; Doyle, Michael P
2014-01-01
The objectives of this study were to quantify Salmonella counts on retail raw poultry meat in Vietnam and to phenotypically characterize (serovars and antibiotic resistance) the isolates. A total of 300 chicken carcasses were collected from two cities and two provinces in Vietnam. Salmonella counts on the samples were determined according to the most-probable-number (MPN) method of the U.S. Department of Agriculture, Food Safety and Inspection Service (USDA-FSIS). A total of 457 isolates were serotyped and tested for antibiotic susceptibility. Overall, 48.7% of chicken samples were Salmonella positive with a count of 2.0 log MPN per carcass. There were no significant differences (P > 0.05) in log MPN per carcass by the study variables (market type, storage condition, and chicken production system). There was a significant difference (P < 0.05) in Salmonella-positive prevalence by chicken production system. Among the 22 Salmonella serovars identified, Albany was the most frequent (34.1%), followed by Agona (15.5%) and Dabou (8.8%). Resistance to at least one antibiotic was common (i.e., 73.3%), with high resistance to tetracycline (59.1%) and ampicillin (41.6%). Resistance to three antibiotics was the most frequently found multidrug resistance profile (17.7%, n = 81); the profile that was resistant to the highest number of drugs was resistant to nine antibiotics (0.7%, n = 3). Only Salmonella Albany posed phenotypic resistance to ceftriaxone (a drug of choice to treat severe cases of salmonellosis). The data revealed that, whereas Salmonella prevalence on raw poultry was high (48.7%), counts were low, which suggests that the exposure risk to Salmonella is low. However, improper storage of raw chicken meat and cross-contamination may increase Salmonella cell counts and pose a greater risk for infection. These data may be helpful in developing risk assessment models and preventing the transmission of foodborne Salmonella from poultry to humans in Vietnam.
CD16-positive circulating monocytes and fibrotic manifestations of systemic sclerosis.
Lescoat, Alain; Lecureur, Valérie; Roussel, Mikael; Sunnaram, Béatrice Ly; Ballerie, Alice; Coiffier, Guillaume; Jouneau, Stéphane; Fardel, Olivier; Fest, Thierry; Jégo, Patrick
2017-07-01
The objective of this study is to assess the association of clinical manifestations of systemic sclerosis (SSc) with the absolute count of circulating blood monocyte subpopulations according to their membrane expression of CD16. Forty-eight consecutive patients fulfilling the 2013 ACR/EULAR classification criteria for SSc were included in this cross-sectional study. CD16+ monocyte absolute count was defined by flow cytometry and confronted to the clinical characteristics of SSc patients. Twenty-three healthy donors (HD) were randomly selected for comparison. SSc patients had an increased number of total circulating blood monocytes compared to HD (p < 0.001). The CD16- subpopulation absolute count was increased in SSc patients compared to HD (p < 0.001) but was similar in limited SSc (lSSc) and diffuse SSc (dSSc). On the contrary, the CD16+ population absolute count was increased in dSSc compared to both HD and lSSc patients (dSSc 0.071 Giga/L (±0.034) vs HD 0.039 Giga/L (±0.030), p < 0.01, and dSSc 0.071 Giga/L (±0.034) vs lSSc 0.048 Giga/L (±0.024), p < 0.05). The CD16+ monocyte subpopulation absolute count was significantly correlated with the severity of skin fibrosis evaluated by the modified Rodnan skin score (p < 0.001). The CD16+ monocyte subpopulation was also associated with pulmonary fibrosis (p < 0.05), with the severity of the restrictive ventilatory defect evaluated by total lung capacity (p < 0.05) and with the pulmonary function impairment reflected by diffusing capacity of the lungs for carbon monoxyde measures (p < 0.01). These results suggest that CD16+ monocytes are associated with the main fibrotic manifestations of SSc and their role in the pathogenesis of fibrosis in this autoimmune disorder should therefore be further considered.
ERIC Educational Resources Information Center
Temple, Viviene A.; Stanish, Heidi I.
2009-01-01
Pedometers are objective, inexpensive, valid, and reliable measures of physical activity. The minimum number of days of pedometer monitoring needed to estimate average weekly step counts was investigated. Seven days of pedometer data were collected from 154 ambulatory men and women ("ns" = 88 and 66, respectively) with intellectual disability.…
Identifying Differences in Early Mathematical Skills among Children in Head Start
ERIC Educational Resources Information Center
Wu, Qiong; Lei, Pui-wa; DiPerna, James C.; Morgan, Paul L.; Reid, Erin E.
2015-01-01
The purpose of this study was to examine early mathematical skill differences among preschool children in US Head Start classrooms. Latent class analysis based on six early mathematical subtest scores (i.e. counting aloud, measurement, counting objects, numbers and shapes, pattern recognition, and grouping) from a sample of 279 Head Start children…
Further Development of Measures of Early Math Performance for Preschoolers
ERIC Educational Resources Information Center
VanDerHeyden, Amanda M.; Broussard, Carmen; Cooley, Amanda
2006-01-01
The purpose of this study was to examine the progress monitoring and screening accuracy for a set of curriculum-based measures (CBM) of early mathematics skills. Measures included counting objects, selecting numbers, naming numbers, counting, and visual discrimination. Measures were designed to be administered with preschoolers in a short period…
For Mole Problems, Call Avogadro: 602-1023.
ERIC Educational Resources Information Center
Uthe, R. E.
2002-01-01
Describes techniques to help introductory students become familiar with Avogadro's number and mole calculations. Techniques involve estimating numbers of common objects then calculating the length of time needed to count large numbers of them. For example, the immense amount of time required to count a mole of sand grains at one grain per second…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okura, Yuki; Futamase, Toshifumi, E-mail: yuki.okura@nao.ac.jp, E-mail: tof@astr.tohoku.ac.jp
This is the third paper on the improvement of systematic errors in weak lensing analysis using an elliptical weight function, referred to as E-HOLICs. In previous papers, we succeeded in avoiding errors that depend on the ellipticity of the background image. In this paper, we investigate the systematic error that depends on the signal-to-noise ratio of the background image. We find that the origin of this error is the random count noise that comes from the Poisson noise of sky counts. The random count noise makes additional moments and centroid shift error, and those first-order effects are canceled in averaging,more » but the second-order effects are not canceled. We derive the formulae that correct this systematic error due to the random count noise in measuring the moments and ellipticity of the background image. The correction formulae obtained are expressed as combinations of complex moments of the image, and thus can correct the systematic errors caused by each object. We test their validity using a simulated image and find that the systematic error becomes less than 1% in the measured ellipticity for objects with an IMCAT significance threshold of {nu} {approx} 11.7.« less
Material separation in x-ray CT with energy resolved photon-counting detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Xiaolan; Meier, Dirk; Taguchi, Katsuyuki
Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. Methods: To demonstrate this capability, we performed simulations and physical experimentsmore » using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. Results: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. Conclusions: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.« less
Extinction map of Chamaeleon I molecular cloud with DENIS star counts.
NASA Astrophysics Data System (ADS)
Cambresy, L.; Epchtein, N.; Copet, E.; de Batz, B.; Kimeswenger, S.; Le Bertre, T.; Rouan, D.; Tiphene, D.
1997-08-01
Massive, large scale star counts in the J (1.25μm) band provided by the Deep Near Infrared Survey of the Southern Sky (DENIS) are used for the first time to draw out an extinction map of the Chamaeleon I dark cloud. We derived a 2' resolution map of the cloud from J star counts within an area of 1.5°x3° around the centre of the cloud using an adaptive grid method and applying a wavelet decomposition. Possible contaminating young stellar objects within the cloud are removed, although they are shown to have a negligible effect on the counts. A comparison of our extinction map with the cold contribution of the IRAS 100μm emission shows an almost perfect matching. It is shown that J star counts supersede optical counts on Schmidt plate where A_V_>4.
Costs of detection bias in index-based population monitoring
Moore, C.T.; Kendall, W.L.
2004-01-01
Managers of wildlife populations commonly rely on indirect, count-based measures of the population in making decisions regarding conservation, harvest, or control. The main appeal in the use of such counts is their low material expense compared to methods that directly measure the population. However, their correct use rests on the rarely-tested but often-assumed premise that they proportionately reflect population size, i.e., that they constitute a population index. This study investigates forest management for the endangered Red-cockaded Woodpecker (Picoides borealis) and the Wood Thrush (Hylocichla mustelina) at the Piedmont National Wildlife Refuge in central Georgia, U.S.A. Optimal decision policies for a joint species objective were derived for two alternative models of Wood Thrush population dynamics. Policies were simulated under scenarios of unbiasedness, consistent negative bias, and habitat-dependent negative bias in observed Wood Thrush densities. Differences in simulation outcomes between biased and unbiased detection scenarios indicated the expected loss in resource objectives (here, forest habitat and birds) through decision-making based on biased population counts. Given the models and objective function used in our analysis, expected losses were as great as 11%, a degree of loss perhaps not trivial for applications such as endangered species management. Our analysis demonstrates that costs of uncertainty about the relationship between the population and its observation can be measured in units of the resource, costs which may offset apparent savings achieved by collecting uncorrected population counts.
Forecasting Emergency Department Crowding: An External, Multi-Center Evaluation
Hoot, Nathan R.; Epstein, Stephen K.; Allen, Todd L.; Jones, Spencer S.; Baumlin, Kevin M.; Chawla, Neal; Lee, Anna T.; Pines, Jesse M.; Klair, Amandeep K.; Gordon, Bradley D.; Flottemesch, Thomas J.; LeBlanc, Larry J.; Jones, Ian; Levin, Scott R.; Zhou, Chuan; Gadd, Cynthia S.; Aronsky, Dominik
2009-01-01
Objective To apply a previously described tool to forecast ED crowding at multiple institutions, and to assess its generalizability for predicting the near-future waiting count, occupancy level, and boarding count. Methods The ForecastED tool was validated using historical data from five institutions external to the development site. A sliding-window design separated the data for parameter estimation and forecast validation. Observations were sampled at consecutive 10-minute intervals during 12 months (n = 52,560) at four sites and 10 months (n = 44,064) at the fifth. Three outcome measures – the waiting count, occupancy level, and boarding count – were forecast 2, 4, 6, and 8 hours beyond each observation, and forecasts were compared to observed data at corresponding times. The reliability and calibration were measured following previously described methods. After linear calibration, the forecasting accuracy was measured using the median absolute error (MAE). Results The tool was successfully used for five different sites. Its forecasts were more reliable, better calibrated, and more accurate at 2 hours than at 8 hours. The reliability and calibration of the tool were similar between the original development site and external sites; the boarding count was an exception, which was less reliable at four out of five sites. Some variability in accuracy existed among institutions; when forecasting 4 hours into the future, the MAE of the waiting count ranged between 0.6 and 3.1 patients, the MAE of the occupancy level ranged between 9.0 and 14.5% of beds, and the MAE of the boarding count ranged between 0.9 and 2.7 patients. Conclusion The ForecastED tool generated potentially useful forecasts of input and throughput measures of ED crowding at five external sites, without modifying the underlying assumptions. Noting the limitation that this was not a real-time validation, ongoing research will focus on integrating the tool with ED information systems. PMID:19716629
Vision 20/20: Single photon counting x-ray detectors in medical imaging
Taguchi, Katsuyuki; Iwanczyk, Jan S.
2013-01-01
Photon counting detectors (PCDs) with energy discrimination capabilities have been developed for medical x-ray computed tomography (CT) and x-ray (XR) imaging. Using detection mechanisms that are completely different from the current energy integrating detectors and measuring the material information of the object to be imaged, these PCDs have the potential not only to improve the current CT and XR images, such as dose reduction, but also to open revolutionary novel applications such as molecular CT and XR imaging. The performance of PCDs is not flawless, however, and it seems extremely challenging to develop PCDs with close to ideal characteristics. In this paper, the authors offer our vision for the future of PCD-CT and PCD-XR with the review of the current status and the prediction of (1) detector technologies, (2) imaging technologies, (3) system technologies, and (4) potential clinical benefits with PCDs. PMID:24089889
Natural language processing and the representation of clinical data.
Sager, N; Lyman, M; Bucknall, C; Nhan, N; Tick, L J
1994-01-01
OBJECTIVE: Develop a representation of clinical observations and actions and a method of processing free-text patient documents to facilitate applications such as quality assurance. DESIGN: The Linguistic String Project (LSP) system of New York University utilizes syntactic analysis, augmented by a sublanguage grammar and an information structure that are specific to the clinical narrative, to map free-text documents into a database for querying. MEASUREMENTS: Information precision (I-P) and information recall (I-R) were measured for queries for the presence of 13 asthma-health-care quality assurance criteria in a database generated from 59 discharge letters. RESULTS: I-P, using counts of major errors only, was 95.7% for the 28-letter training set and 98.6% for the 31-letter test set. I-R, using counts of major omissions only, was 93.9% for the training set and 92.5% for the test set. PMID:7719796
Transverse correlations in triphoton entanglement: Geometrical and physical optics
NASA Astrophysics Data System (ADS)
Wen, Jianming; Xu, P.; Rubin, Morton H.; Shih, Yanhua
2007-08-01
The transverse correlation of triphoton entanglement generated within a single crystal is analyzed. Among many interesting features of the transverse correlation, they arise from the spectral function F of the triphoton state produced in the parametric processes. One consequence of transverse effects of entangled states is quantum imaging, which is theoretically studied in photon counting measurements. Klyshko’s two-photon advanced-wave picture is found to be applicable to the multiphoton entanglement with some modifications. We found that in the two-photon coincidence counting measurement by using triphoton entanglement, although the Gaussian thin lens equation (GTLE) holds, the imaging shown in coincidences is obscure and has a poor quality. This is because of tracing the remaining transverse modes in the untouched beam. In the triphoton imaging experiments, two kinds of cases have been examined. For the case that only one object with one thin lens is placed in the system, we found that the GTLE holds as expected in the triphoton coincidences and the effective distance between the lens and imaging plane is the parallel combination of two distances between the lens and two detectors weighted by wavelengths, which behaves as the parallel combination of resistors in the electromagnetism theory. Only in this case, a point-point correspondence for forming an image is well-accomplished. However, when two objects or two lenses are inserted in the system, though the GTLEs are well-satisfied, in general a point-point correspondence for imaging cannot be established. Under certain conditions, two blurred images may be observed in the coincidence counts. We have also studied the ghost interference-diffraction experiments by using double slits as apertures in triphoton entanglement. It was found that when two double slits are used in two optical beams, the interference-diffraction patterns show unusual features compared with the two-photon case. This unusual behavior is a destructive interference between two amplitudes for two photons crossing two double slits.
Misha, Mehak; Rai, Lavanya
2014-01-01
Objectives. To evaluate the effect of preeclampsia on the cord blood and maternal NRBC count and to correlate NRBC count and neonatal outcome in preeclampsia and control groups. Study Design. This is a prospective case control observational study. Patients and Methods. Maternal and cord blood NRBC counts were studied in 50 preeclamptic women and 50 healthy pregnant women. Using automated cell counter total leucocyte count was obtained and peripheral smear was prepared to obtain NRBC count. Corrected WBC count and NRBC count/100 leucocytes in maternal venous blood and in cord blood were compared between the 2 groups. Results. No significant differences were found in corrected WBC count in maternal and cord blood in cases and controls. Significant differences were found in mean cord blood NRBC count in preeclampsia and control groups (40.0 ± 85.1 and 5.9 ± 6.3, P = 0.006). The mean maternal NRBC count in two groups was 2.4 ± 9.0 and 0.8 ± 1.5, respectively (P = 0.214). Cord blood NRBC count cut off value ≤13 could rule out adverse neonatal outcome with a sensitivity of 63% and specificity of 89%. Conclusion. Cord blood NRBC are significantly raised in preeclampsia. Neonates with elevated cord blood NRBC counts are more likely to have IUGR, low birth weight, neonatal ICU admission, respiratory distress syndrome, and assisted ventilation. Below the count of 13/100 leucocytes, adverse neonatal outcome is quite less likely. PMID:24734183
Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.
Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A
2018-02-01
Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.
Continuous Activity Monitoring During Concurrent Chemoradiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohri, Nitin, E-mail: ohri.nitin@gmail.com; Kabarriti, Rafi; Bodner, William R.
Purpose: To perform a prospective trial testing the feasibility and utility of acquiring activity data as a measure of health status during concurrent chemoradiotherapy. Methods and Materials: Ambulatory patients who were planned for treatment with concurrent chemoradiotherapy with curative intent for cancers of the head and neck, lung, or gastrointestinal tract were provided with activity monitors before treatment initiation. Patients were asked to wear the devices continuously throughout the radiation therapy course. Step count data were downloaded weekly during radiation therapy and 2 and 4 weeks after radiation therapy completion. The primary objective was to demonstrate feasibility, defined as collection ofmore » step counts for 80% of the days during study subjects' radiation therapy courses. Secondary objectives included establishing step count as a dynamic predictor of unplanned hospitalization risk. Results: Thirty-eight enrolled patients were treated with concurrent chemoradiotherapy. Primary diagnoses included head and neck cancer (n=11), lung cancer (n=13), and a variety of gastrointestinal cancers (n=14). Step data were collected for 1524 of 1613 days (94%) during patients' radiation therapy courses. Fourteen patients were hospitalized during radiation therapy or within 4 weeks of radiation therapy completion. Cox regression modeling demonstrated a significant association between recent step counts (3-day average) and hospitalization risk, with a 38% reduction in the risk of hospitalization for every 1000 steps taken each day (hazard ratio 0.62, 95% confidence interval 0.46-0.83, P=.002). Inferior quality of life scores and impaired performance status were not associated with increased hospitalization risk. Conclusion: Continuous activity monitoring during concurrent chemoradiotherapy is feasible and well-tolerated. Step counts may serve as powerful, objective, and dynamic indicators of hospitalization risk.« less
Clemes, Stacy A; O'Connell, Sophie E; Edwardson, Charlotte L
2014-03-01
To examine objectively determined sedentary behavior and physical activity (PA) during and outside working hours in full-time office workers. A total of 170 participants wore an ActiGraph GT1M accelerometer for 7 days. Time spent sedentary (<100 counts/min), in light-intensity PA (100 to 1951 counts/min), and moderate-to-vigorous PA (≥1952 counts/min) was calculated for workdays (including working hours and nonworking hours) and nonworkdays. Participants accumulated significantly higher levels of sedentary behavior (68% vs 60%) and lower levels of light-intensity activity (28% vs 36%) on workdays in comparison with nonworkdays. Up to 71% of working hours were spent sedentary. Individuals who were most sedentary at work were also more sedentary outside work. Those who are most sedentary at work do not compensate by increasing their PA or reducing their sedentary time outside work. Occupational interventions should address workplace and leisure-time sedentary behavior.
Effect of CPAP in a Mouse Model of Hyperoxic Neonatal Lung Injury
Reyburn, Brent; Fiore, Juliann M. Di; Raffay, Thomas; Martin, Richard J.; Y.S., Prakash; Jafri, Anjum; MacFarlane, Peter M.
2015-01-01
Background Continuous positive airway pressure [CPAP] and supplemental oxygen have become the mainstay of neonatal respiratory support in preterm infants. Although oxygen therapy is associated with respiratory morbidities including bronchopulmonary dysplasia [BPD], the long-term effects of CPAP on lung function are largely unknown. We used a hyperoxia-induced mouse model of BPD to explore the effects of daily CPAP during the first week of life on later respiratory system mechanics. Objective To test the hypothesis that daily CPAP in a newborn mouse model of BPD improves longer term respiratory mechanics. Methods Mouse pups from C57BL/6 pregnant dams were exposed to room air [RA] or hyperoxia [50% O2, 24hrs/day] for the first postnatal week with or without exposure to daily CPAP [6cmH2O, 3hrs/day]. Respiratory system resistance [Rrs] and compliance [Crs] were measured following a subsequent 2 week period of room RA recovery. Additional measurements included radial alveolar counts and macrophage counts. Results Mice exposed to hyperoxia had significantly elevated Rrs, decreased Crs, reduced alveolarization, and increased macrophage counts at three weeks compared to RA treated mice. Daily CPAP treatment significantly improved Rrs, Crs and alveolarization, and decreased lung macrophage infiltration in hyperoxia-exposed pups. Conclusions We have demonstrated that daily CPAP had a longer term benefit on baseline respiratory system mechanics in a neonatal mouse model of BPD. We speculate that this beneficial effect of CPAP was the consequence of a decrease in the inflammatory response and resultant alveolar injury associated with hyperoxic newborn lung injury. PMID:26394387
A Video Game Platform for Exploring Satellite and In-Situ Data Streams
NASA Astrophysics Data System (ADS)
Cai, Y.
2014-12-01
Exploring spatiotemporal patterns of moving objects are essential to Earth Observation missions, such as tracking, modeling and predicting movement of clouds, dust, plumes and harmful algal blooms. Those missions involve high-volume, multi-source, and multi-modal imagery data analysis. Analytical models intend to reveal inner structure, dynamics, and relationship of things. However, they are not necessarily intuitive to humans. Conventional scientific visualization methods are intuitive but limited by manual operations, such as area marking, measurement and alignment of multi-source data, which are expensive and time-consuming. A new development of video analytics platform has been in progress, which integrates the video game engine with satellite and in-situ data streams. The system converts Earth Observation data into articulated objects that are mapped from a high-dimensional space to a 3D space. The object tracking and augmented reality algorithms highlight the objects' features in colors, shapes and trajectories, creating visual cues for observing dynamic patterns. The head and gesture tracker enable users to navigate the data space interactively. To validate our design, we have used NASA SeaWiFS satellite images of oceanographic remote sensing data and NOAA's in-situ cell count data. Our study demonstrates that the video game system can reduce the size and cost of traditional CAVE systems in two to three orders of magnitude. This system can also be used for satellite mission planning and public outreaching.
Image reconstructions from super-sampled data sets with resolution modeling in PET imaging.
Li, Yusheng; Matej, Samuel; Metzler, Scott D
2014-12-01
Spatial resolution in positron emission tomography (PET) is still a limiting factor in many imaging applications. To improve the spatial resolution for an existing scanner with fixed crystal sizes, mechanical movements such as scanner wobbling and object shifting have been considered for PET systems. Multiple acquisitions from different positions can provide complementary information and increased spatial sampling. The objective of this paper is to explore an efficient and useful reconstruction framework to reconstruct super-resolution images from super-sampled low-resolution data sets. The authors introduce a super-sampling data acquisition model based on the physical processes with tomographic, downsampling, and shifting matrices as its building blocks. Based on the model, we extend the MLEM and Landweber algorithms to reconstruct images from super-sampled data sets. The authors also derive a backprojection-filtration-like (BPF-like) method for the super-sampling reconstruction. Furthermore, they explore variant methods for super-sampling reconstructions: the separate super-sampling resolution-modeling reconstruction and the reconstruction without downsampling to further improve image quality at the cost of more computation. The authors use simulated reconstruction of a resolution phantom to evaluate the three types of algorithms with different super-samplings at different count levels. Contrast recovery coefficient (CRC) versus background variability, as an image-quality metric, is calculated at each iteration for all reconstructions. The authors observe that all three algorithms can significantly and consistently achieve increased CRCs at fixed background variability and reduce background artifacts with super-sampled data sets at the same count levels. For the same super-sampled data sets, the MLEM method achieves better image quality than the Landweber method, which in turn achieves better image quality than the BPF-like method. The authors also demonstrate that the reconstructions from super-sampled data sets using a fine system matrix yield improved image quality compared to the reconstructions using a coarse system matrix. Super-sampling reconstructions with different count levels showed that the more spatial-resolution improvement can be obtained with higher count at a larger iteration number. The authors developed a super-sampling reconstruction framework that can reconstruct super-resolution images using the super-sampling data sets simultaneously with known acquisition motion. The super-sampling PET acquisition using the proposed algorithms provides an effective and economic way to improve image quality for PET imaging, which has an important implication in preclinical and clinical region-of-interest PET imaging applications.
16 CFR 500.16 - Measurement of container type commodities, how expressed.
Code of Federal Regulations, 2011 CFR
2011-01-01
... be used as containers for other materials or objects, such as bags, cups, boxes, and pans, shall be...) For circular or other generally round shaped containers, except cups, and the like, in terms of count... quantity statement for containers such as cups will be listed in terms of count and liquid capacity per...
16 CFR 500.16 - Measurement of container type commodities, how expressed.
Code of Federal Regulations, 2010 CFR
2010-01-01
... be used as containers for other materials or objects, such as bags, cups, boxes, and pans, shall be...) For circular or other generally round shaped containers, except cups, and the like, in terms of count... quantity statement for containers such as cups will be listed in terms of count and liquid capacity per...
USDA-ARS?s Scientific Manuscript database
Antral follicle counts (AFC) vary among pubertal beef heifers. Our objective was to compare the in vitro maturation and fertilization of oocytes collected from low and high AFC heifers. Previously we reported results using serum-based IVF media and in this study report results using semi-defined m...
ERIC Educational Resources Information Center
Parrish, Jared W.; Gessner, Bradford D.
2010-01-01
Objectives: To accurately count the number of infant maltreatment-related fatalities and to use information from the birth certificates to predict infant maltreatment-related deaths. Methods: A population-based retrospective cohort study of infants born in Alaska for the years 1992 through 2005 was conducted. Risk factor variables were ascertained…
ERIC Educational Resources Information Center
Bonatti, Luca; Frot, Emmanuel; Zangl, Renate; Mehler, Jacques
2002-01-01
How do infants individuate and track objects, and among them objects belonging to their species, when they can only rely on information about the properties of those objects? We propose the Human First Hypothesis (HFH), which posits that infants possess information about their conspecifics and use it to identify and count objects. F. Xu and S.…
Spatial Statistics for Tumor Cell Counting and Classification
NASA Astrophysics Data System (ADS)
Wirjadi, Oliver; Kim, Yoo-Jin; Breuel, Thomas
To count and classify cells in histological sections is a standard task in histology. One example is the grading of meningiomas, benign tumors of the meninges, which requires to assess the fraction of proliferating cells in an image. As this process is very time consuming when performed manually, automation is required. To address such problems, we propose a novel application of Markov point process methods in computer vision, leading to algorithms for computing the locations of circular objects in images. In contrast to previous algorithms using such spatial statistics methods in image analysis, the present one is fully trainable. This is achieved by combining point process methods with statistical classifiers. Using simulated data, the method proposed in this paper will be shown to be more accurate and more robust to noise than standard image processing methods. On the publicly available SIMCEP benchmark for cell image analysis algorithms, the cell count performance of the present paper is significantly more accurate than results published elsewhere, especially when cells form dense clusters. Furthermore, the proposed system performs as well as a state-of-the-art algorithm for the computer-aided histological grading of meningiomas when combined with a simple k-nearest neighbor classifier for identifying proliferating cells.
An Evaluation of Relative Damage to the Powertrain System in Tracked Vehicles
Lee, Sang-Ho; Lee, Jeong-Hwan; Goo, Sang-Hwa; Cho, Yong-Cheol; Cho, Ho-Young
2009-01-01
The objective of this study was to improve the reliability of the endurance test for the powertrain system of military tracked vehicles. The measurement system that measures the driving duty applied to the powertrain system caused by mobility on roads consists of eight analog channels and two pulse channels, including the propeller shaft output torques for the left and right sides. The data obtained from this measurement system can be used to introduce a new technology that produces the output torque of a torque converter and that can be applied to analyze the revolution counting for the endurance and road mobility in the front unit and represent the relative fatigue damages analysis technique and its results according to the driven roads through a cumulative fatigue method. PMID:22573990
A semi-automated image analysis procedure for in situ plankton imaging systems.
Bi, Hongsheng; Guo, Zhenhua; Benfield, Mark C; Fan, Chunlei; Ford, Michael; Shahrestani, Suzan; Sieracki, Jeffery M
2015-01-01
Plankton imaging systems are capable of providing fine-scale observations that enhance our understanding of key physical and biological processes. However, processing the large volumes of data collected by imaging systems remains a major obstacle for their employment, and existing approaches are designed either for images acquired under laboratory controlled conditions or within clear waters. In the present study, we developed a semi-automated approach to analyze plankton taxa from images acquired by the ZOOplankton VISualization (ZOOVIS) system within turbid estuarine waters, in Chesapeake Bay. When compared to images under laboratory controlled conditions or clear waters, images from highly turbid waters are often of relatively low quality and more variable, due to the large amount of objects and nonlinear illumination within each image. We first customized a segmentation procedure to locate objects within each image and extracted them for classification. A maximally stable extremal regions algorithm was applied to segment large gelatinous zooplankton and an adaptive threshold approach was developed to segment small organisms, such as copepods. Unlike the existing approaches for images acquired from laboratory, controlled conditions or clear waters, the target objects are often the majority class, and the classification can be treated as a multi-class classification problem. We customized a two-level hierarchical classification procedure using support vector machines to classify the target objects (< 5%), and remove the non-target objects (> 95%). First, histograms of oriented gradients feature descriptors were constructed for the segmented objects. In the first step all non-target and target objects were classified into different groups: arrow-like, copepod-like, and gelatinous zooplankton. Each object was passed to a group-specific classifier to remove most non-target objects. After the object was classified, an expert or non-expert then manually removed the non-target objects that could not be removed by the procedure. The procedure was tested on 89,419 images collected in Chesapeake Bay, and results were consistent with visual counts with >80% accuracy for all three groups.
A Semi-Automated Image Analysis Procedure for In Situ Plankton Imaging Systems
Bi, Hongsheng; Guo, Zhenhua; Benfield, Mark C.; Fan, Chunlei; Ford, Michael; Shahrestani, Suzan; Sieracki, Jeffery M.
2015-01-01
Plankton imaging systems are capable of providing fine-scale observations that enhance our understanding of key physical and biological processes. However, processing the large volumes of data collected by imaging systems remains a major obstacle for their employment, and existing approaches are designed either for images acquired under laboratory controlled conditions or within clear waters. In the present study, we developed a semi-automated approach to analyze plankton taxa from images acquired by the ZOOplankton VISualization (ZOOVIS) system within turbid estuarine waters, in Chesapeake Bay. When compared to images under laboratory controlled conditions or clear waters, images from highly turbid waters are often of relatively low quality and more variable, due to the large amount of objects and nonlinear illumination within each image. We first customized a segmentation procedure to locate objects within each image and extracted them for classification. A maximally stable extremal regions algorithm was applied to segment large gelatinous zooplankton and an adaptive threshold approach was developed to segment small organisms, such as copepods. Unlike the existing approaches for images acquired from laboratory, controlled conditions or clear waters, the target objects are often the majority class, and the classification can be treated as a multi-class classification problem. We customized a two-level hierarchical classification procedure using support vector machines to classify the target objects (< 5%), and remove the non-target objects (> 95%). First, histograms of oriented gradients feature descriptors were constructed for the segmented objects. In the first step all non-target and target objects were classified into different groups: arrow-like, copepod-like, and gelatinous zooplankton. Each object was passed to a group-specific classifier to remove most non-target objects. After the object was classified, an expert or non-expert then manually removed the non-target objects that could not be removed by the procedure. The procedure was tested on 89,419 images collected in Chesapeake Bay, and results were consistent with visual counts with >80% accuracy for all three groups. PMID:26010260
2012-01-01
Background Most clinical guidelines recommend that AIDS-free, HIV-infected persons with CD4 cell counts below 0.350 × 109 cells/L initiate combined antiretroviral therapy (cART), but the optimal CD4 cell count at which cART should be initiated remains a matter of debate. Objective To identify the optimal CD4 cell count at which cART should be initiated. Design Prospective observational data from the HIV-CAUSAL Collaboration and dynamic marginal structural models were used to compare cART initiation strategies for CD4 thresholds between 0.200 and 0.500 × 109 cells/L. Setting HIV clinics in Europe and the Veterans Health Administration system in the United States. Patients 20 971 HIV-infected, therapy-naive persons with baseline CD4 cell counts at or above 0.500 × 109 cells/L and no previous AIDS-defining illnesses, of whom 8392 had a CD4 cell count that decreased into the range of 0.200 to 0.499 × 109 cells/L and were included in the analysis. Measurements Hazard ratios and survival proportions for all-cause mortality and a combined end point of AIDS-defining illness or death. Results Compared with initiating cART at the CD4 cell count threshold of 0.500 × 109 cells/L, the mortality hazard ratio was 1.01 (95% CI, 0.84 to 1.22) for the 0.350 threshold and 1.20 (CI, 0.97 to 1.48) for the 0.200 threshold. The corresponding hazard ratios were 1.38 (CI, 1.23 to 1.56) and 1.90 (CI, 1.67 to 2.15), respectively, for the combined end point of AIDS-defining illness or death. Limitations CD4 cell count at cART initiation was not randomized. Residual confounding may exist. Conclusion Initiation of cART at a threshold CD4 count of 0.500 × 109 cells/L increases AIDS-free survival. However, mortality did not vary substantially with the use of CD4 thresholds between 0.300 and 0.500 ×109 cells/L. Primary Funding Source National Institutes of Health. PMID:21502648
Vehicle counting system using real-time video processing
NASA Astrophysics Data System (ADS)
Crisóstomo-Romero, Pedro M.
2006-02-01
Transit studies are important for planning a road network with optimal vehicular flow. A vehicular count is essential. This article presents a vehicle counting system based on video processing. An advantage of such system is the greater detail than is possible to obtain, like shape, size and speed of vehicles. The system uses a video camera placed above the street to image transit in real-time. The video camera must be placed at least 6 meters above the street level to achieve proper acquisition quality. Fast image processing algorithms and small image dimensions are used to allow real-time processing. Digital filters, mathematical morphology, segmentation and other techniques allow identifying and counting all vehicles in the image sequences. The system was implemented under Linux in a 1.8 GHz Pentium 4 computer. A successful count was obtained with frame rates of 15 frames per second for images of size 240x180 pixels and 24 frames per second for images of size 180x120 pixels, thus being able to count vehicles whose speeds do not exceed 150 km/h.
Validation of FFM PD counts for screening personality pathology and psychopathy in adolescence.
Decuyper, Mieke; De Clercq, Barbara; De Bolle, Marleen; De Fruyt, Filip
2009-12-01
Miller and colleagues (Miller, Bagby, Pilkonis, Reynolds, & Lynam, 2005) recently developed a Five-Factor Model (FFM) personality disorder (PD) count technique for describing and diagnosing PDs and psychopathy in adulthood. This technique conceptualizes PDs relying on general trait models and uses facets from the expert-generated PD prototypes to score the FFM PDs. The present study corroborates on the study of Miller and colleagues (2005) and investigates in Study 1 whether the PD count technique shows discriminant validity to describe PDs in adolescence. Study 2 extends this objective to psychopathy. Results suggest that the FFM PD count technique is equally successful in adolescence as in adulthood to describe PD symptoms, supporting the use of this descriptive method in adolescence. The normative data and accompanying PD count benchmarks enable to use FFM scores for PD screening purposes in adolescence.
Development of an ideal observer that incorporates nuisance parameters and processes list-mode data
MacGahan, Christopher Jonathan; Kupinski, Matthew Alan; Hilton, Nathan R.; ...
2016-02-01
Observer models were developed to process data in list-mode format in order to perform binary discrimination tasks for use in an arms-control-treaty context. Data used in this study was generated using GEANT4 Monte Carlo simulations for photons using custom models of plutonium inspection objects and a radiation imaging system. We evaluated observer model performance and then presented using the area under the receiver operating characteristic curve. Lastly, we studied the ideal observer under both signal-known-exactly conditions and in the presence of unknowns such as object orientation and absolute count-rate variability; when these additional sources of randomness were present, their incorporationmore » into the observer yielded superior performance.« less
The binary Kuiper-belt object 1998 WW31.
Veillet, Christian; Parker, Joel Wm; Griffin, Ian; Marsden, Brian; Doressoundiram, Alain; Buie, Marc; Tholen, David J; Connelley, Michael; Holman, Matthew J
2002-04-18
The recent discovery of a binary asteroid during a spacecraft fly-by generated keen interest, because the orbital parameters of binaries can provide measures of the masses, and mutual eclipses could allow us to determine individual sizes and bulk densities. Several binary near-Earth, main-belt and Trojan asteroids have subsequently been discovered. The Kuiper belt-the region of space extending from Neptune (at 30 astronomical units) to well over 100 AU and believed to be the source of new short-period comets-has become a fascinating new window onto the formation of our Solar System since the first member object, not counting Pluto, was discovered in 1992 (ref. 13). Here we report that the Kuiper-belt object 1998 WW31 is binary with a highly eccentric orbit (eccentricity e approximately 0.8) and a long period (about 570 days), very different from the Pluto/Charon system, which was hitherto the only previously known binary in the Kuiper belt. Assuming a density in the range of 1 to 2 g cm-3, the albedo of the binary components is between 0.05 and 0.08, close to the value of 0.04 generally assumed for Kuiper-belt objects.
New non-invasive automatic cough counting program based on 6 types of classified cough sounds.
Murata, Akira; Ohota, Nao; Shibuya, Atsuo; Ono, Hiroshi; Kudoh, Shoji
2006-01-01
Cough consisting of an initial deep inspiration, glottal closure, and an explosive expiration accompanied by a sound is one of the most common symptoms of respiratory disease. Despite its clinical importance, standard methods for objective cough analysis have yet to be established. We investigated the characteristics of cough sounds acoustically, designed a program to discriminate cough sounds from other sounds, and finally developed a new objective method of non-invasive cough counting. In addition, we evaluated the clinical efficacy of that program. We recorded cough sounds using a memory stick IC recorder in free-field from 2 patients and analyzed the intensity of 534 recorded coughs acoustically according to time domain. First we squared the sound waveform of recorded cough sounds, which was then smoothed out over a 20 ms window. The 5 parameters and some definitions to discriminate the cough sounds from other noise were identified and the cough sounds were classified into 6 groups. Next, we applied this method to develop a new automatic cough count program. Finally, to evaluate the accuracy and clinical usefulness of this program, we counted cough sounds collected from another 10 patients using our program and conventional manual counting. And the sensitivity, specificity and discriminative rate of the program were analyzed. This program successfully discriminated recorded cough sounds out of 1902 sound events collected from 10 patients at a rate of 93.1%. The sensitivity was 90.2% and the specificity was 96.5%. Our new cough counting program can be sufficiently useful for clinical studies.
Sileshi, G
2006-10-01
Researchers and regulatory agencies often make statistical inferences from insect count data using modelling approaches that assume homogeneous variance. Such models do not allow for formal appraisal of variability which in its different forms is the subject of interest in ecology. Therefore, the objectives of this paper were to (i) compare models suitable for handling variance heterogeneity and (ii) select optimal models to ensure valid statistical inferences from insect count data. The log-normal, standard Poisson, Poisson corrected for overdispersion, zero-inflated Poisson, the negative binomial distribution and zero-inflated negative binomial models were compared using six count datasets on foliage-dwelling insects and five families of soil-dwelling insects. Akaike's and Schwarz Bayesian information criteria were used for comparing the various models. Over 50% of the counts were zeros even in locally abundant species such as Ootheca bennigseni Weise, Mesoplatys ochroptera Stål and Diaecoderus spp. The Poisson model after correction for overdispersion and the standard negative binomial distribution model provided better description of the probability distribution of seven out of the 11 insects than the log-normal, standard Poisson, zero-inflated Poisson or zero-inflated negative binomial models. It is concluded that excess zeros and variance heterogeneity are common data phenomena in insect counts. If not properly modelled, these properties can invalidate the normal distribution assumptions resulting in biased estimation of ecological effects and jeopardizing the integrity of the scientific inferences. Therefore, it is recommended that statistical models appropriate for handling these data properties be selected using objective criteria to ensure efficient statistical inference.
Chavali, Pooja; Uppin, Megha S; Uppin, Shantveer G; Challa, Sundaram
2017-01-01
The most reliable histological correlate of recurrence risk in meningiomas is increased mitotic activity. Proliferative index with Ki-67 immunostaining is a helpful adjunct to manual counting. However, both show considerable inter-observer variability. A new immunohistochemical method for counting mitotic figures, using antibody against the phosphohistone H3 (PHH3) protein was introduced. Similarly, a computer based automated counting for Ki-67 labelling index (LI) is available. To study the use of these new techniques in the objective assessment of proliferation indices in meningiomas. This was a retrospective study of intracranial meningiomas diagnosed during the year 2013.The hematoxylin and eosin (H and E) sections and immunohistochemistry (IHC) with Ki-67 were reviewed by two pathologists. Photomicrographs of the representative areas were subjected to Ki-67 analysis by Immunoratio (IR) software. Mean Ki-67 LI, both manual and by IR were calculated. IHC with PHH3 was performed. PHH3 positive nuclei were counted and mean values calculated. Data analysis was done using SPSS software. A total of 64 intracranial meningiomas were diagnosed. Evaluation on H and E, PHH3, Ki-67 LI (both manual and IR) were done in 32 cases (22 grade I and 10 grade II meningiomas). Statistically significant correlation was seen between the mitotic count in each grade and PHH3 values and also between the grade of the tumor and values of Ki-67 and PHH3. Both the techniques used in the study had advantage over, as well as, correlated well with the existing techniques and hence, can be applied to routine use.
Russell F. Thurow
2000-01-01
Research was begun in 1995 to describe factors influencing the spatial dynamics and persistence of federally listed chinook salmon within the Frank Church River of No Return Wilderness. Results addressed two objectives: 1) description of chinook salmon redd distributions, and 2) comparison of index and total redd counts. Annual redd counts ranged from 20 to 661, and 99...
ERIC Educational Resources Information Center
Petersen, Lori A.
2013-01-01
When counting, the final word used to tag the final item in a set represents the cardinality, or total number, of the set. Understanding of this concept serves as a foundation for children's basic mathematical skills, such as arithmetic. However, little is known about how variations in the early learning environment affect children's understanding…
Effect of antral follicle count in beef heifers on in vitro fertilization/production
USDA-ARS?s Scientific Manuscript database
Our objective has been to compare the in vitro fertilization (IVF) and production (IVP) of embryos from low and high antral follicle count (AFC) heifers. This is the 4th year of the study with years 1 to 3 reported individually. For this report, we add data for the 4th year and present a combined an...
A whole-system approach to x-ray spectroscopy in cargo inspection systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langeveld, Willem G. J.; Gozani, Tsahi; Ryge, Peter
The bremsstrahlung x-ray spectrum used in high-energy, high-intensity x-ray cargo inspection systems is attenuated and modified by the materials in the cargo in a Z-dependent way. Therefore, spectroscopy of the detected x rays yields information about the Z of the x-rayed cargo material. It has previously been shown that such ZSpectroscopy (Z-SPEC) is possible under certain circumstances. A statistical approach, Z-SCAN (Z-determination by Statistical Count-rate ANalysis), has also been shown to be effective, and it can be used either by itself or in conjunction with Z-SPEC when the x-ray count rate is too high for individual x-ray spectroscopy. Both techniquesmore » require fast x-ray detectors and fast digitization electronics. It is desirable (and possible) to combine all techniques, including x-ray imaging of the cargo, in a single detector array, to reduce costs, weight, and overall complexity. In this paper, we take a whole-system approach to x-ray spectroscopy in x-ray cargo inspection systems, and show how the various parts interact with one another. Faster detectors and read-out electronics are beneficial for both techniques. A higher duty-factor x-ray source allows lower instantaneous count rates at the same overall x-ray intensity, improving the range of applicability of Z-SPEC in particular. Using an intensity-modulated advanced x-ray source (IMAXS) allows reducing the x-ray count rate for cargoes with higher transmission, and a stacked-detector approach may help material discrimination for the lowest attenuations. Image processing and segmentation allow derivation of results for entire objects, and subtraction of backgrounds. We discuss R and D performed under a number of different programs, showing progress made in each of the interacting subsystems. We discuss results of studies into faster scintillation detectors, including ZnO, BaF{sub 2} and PbWO{sub 4}, as well as suitable photo-detectors, read-out and digitization electronics. We discuss high-duty-factor linear-accelerator x-ray sources and their associated requirements, and how such sources improve spectroscopic techniques. We further discuss how image processing techniques help in correcting for backgrounds and overlapping materials. In sum, we present an integrated picture of how to optimize a cargo inspection system for x-ray spectroscopy.« less
Counting statistics for genetic switches based on effective interaction approximation
NASA Astrophysics Data System (ADS)
Ohkubo, Jun
2012-09-01
Applicability of counting statistics for a system with an infinite number of states is investigated. The counting statistics has been studied a lot for a system with a finite number of states. While it is possible to use the scheme in order to count specific transitions in a system with an infinite number of states in principle, we have non-closed equations in general. A simple genetic switch can be described by a master equation with an infinite number of states, and we use the counting statistics in order to count the number of transitions from inactive to active states in the gene. To avoid having the non-closed equations, an effective interaction approximation is employed. As a result, it is shown that the switching problem can be treated as a simple two-state model approximately, which immediately indicates that the switching obeys non-Poisson statistics.
Assessing Rotation-Invariant Feature Classification for Automated Wildebeest Population Counts.
Torney, Colin J; Dobson, Andrew P; Borner, Felix; Lloyd-Jones, David J; Moyer, David; Maliti, Honori T; Mwita, Machoke; Fredrick, Howard; Borner, Markus; Hopcraft, J Grant C
2016-01-01
Accurate and on-demand animal population counts are the holy grail for wildlife conservation organizations throughout the world because they enable fast and responsive adaptive management policies. While the collection of image data from camera traps, satellites, and manned or unmanned aircraft has advanced significantly, the detection and identification of animals within images remains a major bottleneck since counting is primarily conducted by dedicated enumerators or citizen scientists. Recent developments in the field of computer vision suggest a potential resolution to this issue through the use of rotation-invariant object descriptors combined with machine learning algorithms. Here we implement an algorithm to detect and count wildebeest from aerial images collected in the Serengeti National Park in 2009 as part of the biennial wildebeest count. We find that the per image error rates are greater than, but comparable to, two separate human counts. For the total count, the algorithm is more accurate than both manual counts, suggesting that human counters have a tendency to systematically over or under count images. While the accuracy of the algorithm is not yet at an acceptable level for fully automatic counts, our results show this method is a promising avenue for further research and we highlight specific areas where future research should focus in order to develop fast and accurate enumeration of aerial count data. If combined with a bespoke image collection protocol, this approach may yield a fully automated wildebeest count in the near future.
Methods of recording and analysing cough sounds.
Subburaj, S; Parvez, L; Rajagopalan, T G
1996-01-01
Efforts have been directed to evolve a computerized system for acquisition and multi-dimensional analysis of the cough sound. The system consists of a PC-AT486 computer with an ADC board having 12 bit resolution. The audio cough sound is acquired using a sensitive miniature microphone at a sampling rate of 8 kHz in the computer and simultaneously recorded in real time using a digital audio tape recorder which also serves as a back up. Analysis of the cough sound is done in time and frequency domains using the digitized data which provide numerical values for key parameters like cough counts, bouts, their intensity and latency. In addition, the duration of each event and cough patterns provide a unique tool which allows objective evaluation of antitussive and expectorant drugs. Both on-line and off-line checks ensure error-free performance over long periods of time. The entire system has been evaluated for sensitivity, accuracy, precision and reliability. Successful use of this system in clinical studies has established what perhaps is the first integrated approach for the objective evaluation of cough.
A comparison of the performance of digital mammography systems.
Monnin, P; Gutierrez, D; Bulling, S; Guntern, D; Verdun, F R
2007-03-01
An objective analysis of image quality parameters was performed for six digital mammography systems. The presampled modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) for the systems were determined at different doses, for 28 kVp with a Mo/Mo or W/Al target/filter combination and 2 mm of additional aluminium filtration. The flat-panel units have higher MTF and DQE in the mid to high frequency range than standard CR systems. The highest DQE, over the whole dose range, is for the slit-scanning direct photon counting system. Dual-side read CR can overcome the inherent x-ray absorption and signal collection limitations of standard CR mammography, improving the low-frequency DQE by 40%, to the same level as full-field systems, but it does not improve the poor spatial resolution of phosphor.
Within-site variability in surveys of wildlife populations
Link, William A.; Barker, Richard J.; Sauer, John R.; Droege, Sam
1994-01-01
Most large-scale surveys of animal populations are based on counts of individuals observed during a sampling period, which are used as indexes to the population. The variability in these indexes not only reflects variability in population sizes among sites but also variability due to the inexactness of the counts. Repeated counts at survey sites can be used to document this additional source of variability and, in some applications, to mitigate its effects. We present models for evaluating the proportion of total variability in counts that is attributable to this within-site variability and apply them in the analysis of data from repeated counts on routes from the North American Breeding Bird Survey. We analyzed data on 98 species, obtaining estimates of these percentages, which ranged from 3.5 to 100% with a mean of 36.25%. For at least 14 of the species, more than half of the variation in counts was attributable to within-site sources. Counts for species with lower average counts had a higher percentage of within-site variability. We discuss the relative cost efficiency of replicating sites or initiating new sites for several objectives, concluding that it is frequently better to initiate new sites than to attempt to replicate existing sites.
Activity Monitors Step Count Accuracy in Community-Dwelling Older Adults.
Johnson, Marquell
2015-01-01
Objective: To examine the step count accuracy of activity monitors in community-dwelling older adults. Method : Twenty-nine participants aged 67.70 ± 6.07 participated. Three pedometers and the Actical accelerometer step count functions were compared with actual steps taken during a 200-m walk around an indoor track and during treadmill walking at three different speeds. Results : There was no statistical difference between activity monitors step counts and actual steps during self-selected pace walking. During treadmill walking at 0.67 m∙s -1 , all activity monitors step counts were significantly different from actual steps. During treadmill walking at 0.894m∙s -1 , the Omron HJ-112 pedometer step counts were not significantly different from actual steps. During treadmill walking at 1.12 m∙s -1 , the Yamax SW-200 pedometer steps were significantly different from actual steps. Discussion : Activity monitor selection should be deliberate when examining the walking behaviors of community-dwelling older adults, especially for those who walk at a slower pace.
Activity Monitors Step Count Accuracy in Community-Dwelling Older Adults
2015-01-01
Objective: To examine the step count accuracy of activity monitors in community-dwelling older adults. Method: Twenty-nine participants aged 67.70 ± 6.07 participated. Three pedometers and the Actical accelerometer step count functions were compared with actual steps taken during a 200-m walk around an indoor track and during treadmill walking at three different speeds. Results: There was no statistical difference between activity monitors step counts and actual steps during self-selected pace walking. During treadmill walking at 0.67 m∙s−1, all activity monitors step counts were significantly different from actual steps. During treadmill walking at 0.894m∙s−1, the Omron HJ-112 pedometer step counts were not significantly different from actual steps. During treadmill walking at 1.12 m∙s−1, the Yamax SW-200 pedometer steps were significantly different from actual steps. Discussion: Activity monitor selection should be deliberate when examining the walking behaviors of community-dwelling older adults, especially for those who walk at a slower pace. PMID:28138464
Donnell, Deborah J; Baeten, Jared M; Hong, Ting; Lingappa, Jairam R; Mujugira, Andrew; Nakku-Joloba, Edith; Bangsberg, David; Celum, Connie
2013-02-01
Clinic-based pill counts of unused study medication are frequently used to measure adherence in HIV-1 prevention trials. Monthly pill count adherence data from the Partners in Prevention HSV/HIV Transmission Study, a double-blind, placebo controlled trial of twice-daily acyclovir suppression of herpes simplex virus type 2 (HSV-2) in HIV-1 infected persons was used to compare changes between 3,381 placebo and active arm participants in two objective biologic measures of acyclovir's drug activity: reduction in plasma HIV-1 RNA and HSV-2 genital ulcer disease (GUD). Higher acyclovir pill count adherence was associated with greater reductions in plasma HIV-1 RNA and GUD, indicating pill count data is strongly correlated with biological effects of adherence. However, when calculated adherence exceeded 102 % (i.e., fewer pills returned than expected) and when pill counts were missing because bottles were not returned, plasma HIV-1 RNA and GUD effects were diminished, likely indicating periods of non-adherence.
Fiber optic temperature sensor gives rise to thermal analysis in complex product design
NASA Astrophysics Data System (ADS)
Cheng, Andrew Y. S.; Pau, Michael C. Y.
1996-09-01
A computer-adapted fiber-optic temperature sensing system has been developed which aims to study both the theoretical aspect of fiber temperature sensing and the experimental aspect of such system. The system consists of a laser source, a fiber sensing element, an electronic fringes counting device, and an on-line personal computer. The temperature measurement is achieved by the conventional double beam fringe counting method with optical path length changes in the sensing beam due to the fiber expansion. The system can automatically measure the temperature changes in a sensing fiber arm which provides an insight of the heat generation and dissipation of the measured system. Unlike the conventional measuring devices such as thermocouples or solid state temperature sensors, the fiber sensor can easily be wrapped and shaped to fit the surface of the measuring object or even inside a molded plastic parts such as a computer case, which gives much more flexibility and applicability to the analysis of heat generation and dissipation in the operation of these machine parts. The reference beam is being set up on a temperature controlled optical bench to facilitate high sensitivity and high temperature resolution. The measuring beam has a motorized beam selection device for multiple fiber beam measurement. The project has been demonstrated in the laboratory and the system sensitivity and resolution are found to be as high as 0.01 degree Celsius. It is expected the system will find its application in many design studies which require thermal budgeting.
Contrast-enhanced spectral mammography with a photon-counting detector.
Fredenberg, Erik; Hemmendorff, Magnus; Cederström, Björn; Aslund, Magnus; Danielsson, Mats
2010-05-01
Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another approximately 70%-90% improvement was found to be within reach for an optimized system. Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.
Automated food microbiology: potential for the hydrophobic grid-membrane filter.
Sharpe, A N; Diotte, M P; Dudas, I; Michaud, G L
1978-01-01
Bacterial counts obtained on hydrophobic grid-membrane filters were comparable to conventional plate counts for Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus in homogenates from a range of foods. The wide numerical operating range of the hydrophobic grid-membrane filters allowed sequential diluting to be reduced or even eliminated, making them attractive as components in automated systems of analysis. Food debris could be rinsed completely from the unincubated hydrophobic grid-membrane filter surface without affecting the subsequent count, thus eliminating the possibility of counting food particles, a common source of error in electronic counting systems. PMID:100054
Tschentscher, Nadja; Hauk, Olaf; Fischer, Martin H.; Pulvermüller, Friedemann
2012-01-01
The embodied cognition framework suggests that neural systems for perception and action are engaged during higher cognitive processes. In an event-related fMRI study, we tested this claim for the abstract domain of numerical symbol processing: is the human cortical motor system part of the representation of numbers, and is organization of numerical knowledge influenced by individual finger counting habits? Developmental studies suggest a link between numerals and finger counting habits due to the acquisition of numerical skills through finger counting in childhood. In the present study, digits 1 to 9 and the corresponding number words were presented visually to adults with different finger counting habits, i.e. left- and right-starters who reported that they usually start counting small numbers with their left and right hand, respectively. Despite the absence of overt hand movements, the hemisphere contralateral to the hand used for counting small numbers was activated when small numbers were presented. The correspondence between finger counting habits and hemispheric motor activation is consistent with an intrinsic functional link between finger counting and number processing. PMID:22133748
White blood cell counting system
NASA Technical Reports Server (NTRS)
1972-01-01
The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.
May, Margaret T.; Gompels, Mark; Delpech, Valerie; Porter, Kholoud; Orkin, Chloe; Kegg, Stephen; Hay, Phillip; Johnson, Margaret; Palfreeman, Adrian; Gilson, Richard; Chadwick, David; Martin, Fabiola; Hill, Teresa; Walsh, John; Post, Frank; Fisher, Martin; Ainsworth, Jonathan; Jose, Sophie; Leen, Clifford; Nelson, Mark; Anderson, Jane; Sabin, Caroline
2014-01-01
Objective: The objective of this study is to estimate life expectancies of HIV-positive patients conditional on response to antiretroviral therapy (ART). Methods: Patients aged more than 20 years who started ART during 2000–2010 (excluding IDU) in HIV clinics contributing to the UK CHIC Study were followed for mortality until 2012. We determined the latest CD4+ cell count and viral load before ART and in each of years 1–5 of ART. For each duration of ART, life tables based on estimated mortality rates by sex, age, latest CD4+ cell count and viral suppression (HIV-1 RNA <400 copies/ml), were used to estimate expected age at death for ages 20–85 years. Results: Of 21 388 patients who started ART, 961 (4.5%) died during 110 697 person-years. At start of ART, expected age at death [95% confidence interval (CI)] of 35-year-old men with CD4+ cell count less than 200, 200–349, at least 350 cells/μl was 71 (68–73), 78 (74–82) and 77 (72–81) years, respectively, compared with 78 years for men in the general UK population. Thirty-five-year-old men who increased their CD4+ cell count in the first year of ART from less than 200 to 200–349 or at least 350 cells/μl and achieved viral suppression gained 7 and 10 years, respectively. After 5 years on ART, expected age at death of 35-year-old men varied from 54 (48–61) (CD4+ cell count <200 cells/μl and no viral suppression) to 80 (76–83) years (CD4+ cell count ≥350 cells/μl and viral suppression). Conclusion: Successfully treated HIV-positive individuals have a normal life expectancy. Patients who started ART with a low CD4+ cell count significantly improve their life expectancy if they have a good CD4+ cell count response and undetectable viral load. PMID:24556869
Minimum Disclosure Counting for the Alternative Vote
NASA Astrophysics Data System (ADS)
Wen, Roland; Buckland, Richard
Although there is a substantial body of work on preventing bribery and coercion of voters in cryptographic election schemes for plurality electoral systems, there are few attempts to construct such schemes for preferential electoral systems. The problem is preferential systems are prone to bribery and coercion via subtle signature attacks during the counting. We introduce a minimum disclosure counting scheme for the alternative vote preferential system. Minimum disclosure provides protection from signature attacks by revealing only the winning candidate.
NASA Astrophysics Data System (ADS)
Matsushita, Ryo; Sato, Eiichi; Yanbe, Yutaka; Chiba, Hiraku; Maeda, Tomoko; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2013-03-01
A low-dose-rate X-ray computed tomography (CT) system is useful for reducing absorbed dose for patients. The CT system with a tube current of sub-mA was developed using a silicon X-ray diode (Si-XD). The Si-XD is a high-sensitivity Si photodiode (PD) selected for detecting X-ray photons, and the X-ray sensitivity of the Si-XD was twice as high as that of Si-PD cerium-doped yttrium aluminum perovskite [YAP(Ce)]. X-ray photons are directly detected using the Si-XD without a scintillator, and the photocurrent from the diode is amplified using current-voltage and voltage-voltage amplifiers. The output voltage is converted into logical pulses using a voltage-frequency converter with a maximum frequency of 500 kHz, and the frequency is proportional to the voltage. The pulses from the converter are sent to the differentiator with a time constant of 500 ns to generate short positive pulses for counting, and the pulses are counted using a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The exposure time for obtaining a tomogram was 5 min at a scan step of 0.5 mm and a rotation step of 3.0°. The tube current and voltage were 0.55 mA and 60 kV, respectively, and iodine K-edge CT was carried out using filtered bremsstrahlung X-ray spectra with a peak energy of 38 keV.
Space Transportation System Availability Requirements and Its Influencing Attributes Relationships
NASA Technical Reports Server (NTRS)
Rhodes, Russel E.; Adams, TImothy C.
2008-01-01
It is essential that management and engineering understand the need for an availability requirement for the customer's space transportation system as it enables the meeting of his needs, goal, and objectives. There are three types of availability, e.g., operational availability, achieved availability, or inherent availability. The basic definition of availability is equal to the mean uptime divided by the sum of the mean uptime plus the mean downtime. The major difference is the inclusiveness of the functions within the mean downtime and the mean uptime. This paper will address tIe inherent availability which only addresses the mean downtime as that mean time to repair or the time to determine the failed article, remove it, install a replacement article and verify the functionality of the repaired system. The definitions of operational availability include the replacement hardware supply or maintenance delays and other non-design factors in the mean downtime. Also with inherent availability the mean uptime will only consider the mean time between failures (other availability definitions consider this as mean time between maintenance - preventive and corrective maintenance) that requires the repair of the system to be functional. It is also essential that management and engineering understand all influencing attributes relationships to each other and to the resultant inherent availability requirement. This visibility will provide the decision makers with the understanding necessary to place constraints on the design definition for the major drivers that will determine the inherent availability, safety, reliability, maintainability, and the life cycle cost of the fielded system provided the customer. This inherent availability requirement may be driven by the need to use a multiple launch approach to placing humans on the moon or the desire to control the number of spare parts required to support long stays in either orbit or on the surface of the moon or mars. It is the intent of this paper to provide the visibility of relationships of these major attribute drivers (variables) to each other and the resultant system inherent availability, but also provide the capability to bound the variables providing engineering the insight required to control the system's engineering solution. An example of this visibility will be the need to provide integration of similar discipline functions to allow control of the total parts count of the space transportation system. Also the relationship visibility of selecting a reliability requirement will place a constraint on parts count to achieve a given inherent availability requirement or accepting a larger parts count with the resulting higher reliability requirement. This paper will provide an understanding for the relationship of mean repair time (mean downtime) to maintainability, e.g., accessibility for repair, and both mean time between failure, e.g., reliability of hardware and the system inherent availability. Having an understanding of these relationships and resulting requirements before starting the architectural design concept definition will avoid considerable time and money required to iterate the design to meet the redesign and assessment process required to achieve the results required of the customer's space transportation system. In fact the impact to the schedule to being able to deliver the system that meets the customer's needs, goals, and objectives may cause the customer to compromise his desired operational goal and objectives resulting in considerable increased life cycle cost of the fielded space transportation system.
Measuring Transmission Efficiencies Of Mass Spectrometers
NASA Technical Reports Server (NTRS)
Srivastava, Santosh K.
1989-01-01
Coincidence counts yield absolute efficiencies. System measures mass-dependent transmission efficiencies of mass spectrometers, using coincidence-counting techniques reminiscent of those used for many years in calibration of detectors for subatomic particles. Coincidences between detected ions and electrons producing them counted during operation of mass spectrometer. Under certain assumptions regarding inelastic scattering of electrons, electron/ion-coincidence count is direct measure of transmission efficiency of spectrometer. When fully developed, system compact, portable, and used routinely to calibrate mass spectrometers.
Acute Effects of Fine Particulate Air Pollution on Cardiac Arrhythmia: The APACR Study
He, Fan; Shaffer, Michele L.; Rodriguez-Colon, Sol; Yanosky, Jeff D.; Bixler, Edward; Cascio, Wayne E.
2011-01-01
Background: The mechanisms underlying the relationship between particulate matter (PM) air pollution and cardiac disease are not fully understood. Objectives: We examined the effects and time course of exposure to fine PM [aerodynamic diameter ≤ 2.5 μm (PM2.5)] on cardiac arrhythmia in 105 middle-age community-dwelling healthy nonsmokers in central Pennsylvania. Methods: The 24-hr beat-to-beat electrocardiography data were obtained using a high-resolution Holter system. After visually identifying and removing artifacts, we summarized the total number of premature ventricular contractions (PVCs) and premature atrial contractions (PACs) for each 30-min segment. A personal PM2.5 nephelometer was used to measure individual-level real-time PM2.5 exposures for 24 hr. We averaged these data to obtain 30-min average time–specific PM2.5 exposures. Distributed lag models under the framework of negative binomial regression and generalized estimating equations were used to estimate the rate ratio between 10-μg/m3 increases in average PM2.5 over 30-min intervals and ectopy counts. Results: The mean ± SD age of participants was 56 ± 8 years, with 40% male and 73% non-Hispanic white. The 30-min mean ± SD for PM2.5 exposure was 13 ± 22 μg/m3, and PAC and PVC counts were 0.92 ± 4.94 and 1.22 ± 7.18. Increases of 10 μg/m3 in average PM2.5 concentrations during the same 30 min or the previous 30 min were associated with 8% and 3% increases in average PVC counts, respectively. PM2.5 was not significantly associated with PAC count. Conclusion: PM2.5 exposure within approximately 60 min was associated with increased PVC counts in healthy individuals. PMID:21398201
Ho, Kimberly K; Abrams-Ogg, Anthony C G; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L
2015-05-01
The objectives of this study were to establish feline references intervals for 3 commercial whole blood platelet function test analyzer systems: Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), Platelet Function Analyzer-100 (PF: Siemens Canada, Mississauga, Ontario, Canada), and Plateletworks Combo-25 kit (PW; Helena Laboratories, Beaumont, TX). Venipuncture was performed on 55 healthy sedated cats, and platelet aggregation in response to adenosine diphosphate (ADP), collagen (COL), and arachidonic acid (AA; MP only) was assessed using citrated blood. For the MP analyzer, median (95% confidence intervals [CIs]) area under curve (Units) for ADP, COL, and AA agonists were 87 (11-176), 81 (32-129), and 91 (59-129), respectively. For the PF analyzer, median (95% CIs) closure time, using COL-ADP cartridges, was 69 (46-89) sec. For the PW assay, median (95% CIs) percent aggregations for ADP and COL agonists were 71 (18-92) and 49 (9-96), respectively, using impedance hematology analyzer platelet counts, and 94 (25-98) and 68 (14-119), respectively, using flow cytometry hematology analyzer platelet counts. There were low correlations between the PF analyzer (COL-ADP cartridge) and MP analyzer (COL agonist; ρ = 0.11), and between the PF analyzer (COL-ADP cartridge) and PW assay (COL agonist using impedance platelet counts; ρ = 0.14). The PW assay percent aggregations using impedance and flow cytometric platelet counts were correlated for both ADP (ρ = 0.64) and COL (ρ = 0.64) agonists. Platelet function testing using these tests are feasible in cats, but 95% CIs are wide, so single results may be difficult to interpret. Platelet counting by impedance or flow cytometry may be used for the PW assay but are not interchangeable. © 2015 The Author(s).
500-MHz x-ray counting with a Si-APD and a fast-pulse processing system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kishimoto, Shunji; Taniguchi, Takashi; Tanaka, Manobu
2010-06-23
We introduce a counting system of up to 500 MHz for synchrotron x-ray high-rate measurements. A silicon avalanche photodiode detector was used in the counting system. The fast-pulse circuit of the amplifier was designed with hybrid ICs to prepare an ASIC system for a large-scale pixel array detector in near future. The fast amplifier consists of two cascading emitter-followers using 10-GHz band transistors. A count-rate of 3.25x10{sup 8} s{sup -1} was then achieved using the system for 8-keV x-rays. However, a baseline shift by adopting AC-coupling in the amplifier disturbed us to observe the maximum count of 4.49x10{sup 8} s{supmore » -1}, determined by electron-bunch filling into a ring accelerator. We also report that an amplifier with a baseline restorer was tested in order to keep the baseline level to be 0 V even at high input rates.« less
Characterizing the performance of the Conway-Maxwell Poisson generalized linear model.
Francis, Royce A; Geedipally, Srinivas Reddy; Guikema, Seth D; Dhavala, Soma Sekhar; Lord, Dominique; LaRocca, Sarah
2012-01-01
Count data are pervasive in many areas of risk analysis; deaths, adverse health outcomes, infrastructure system failures, and traffic accidents are all recorded as count events, for example. Risk analysts often wish to estimate the probability distribution for the number of discrete events as part of doing a risk assessment. Traditional count data regression models of the type often used in risk assessment for this problem suffer from limitations due to the assumed variance structure. A more flexible model based on the Conway-Maxwell Poisson (COM-Poisson) distribution was recently proposed, a model that has the potential to overcome the limitations of the traditional model. However, the statistical performance of this new model has not yet been fully characterized. This article assesses the performance of a maximum likelihood estimation method for fitting the COM-Poisson generalized linear model (GLM). The objectives of this article are to (1) characterize the parameter estimation accuracy of the MLE implementation of the COM-Poisson GLM, and (2) estimate the prediction accuracy of the COM-Poisson GLM using simulated data sets. The results of the study indicate that the COM-Poisson GLM is flexible enough to model under-, equi-, and overdispersed data sets with different sample mean values. The results also show that the COM-Poisson GLM yields accurate parameter estimates. The COM-Poisson GLM provides a promising and flexible approach for performing count data regression. © 2011 Society for Risk Analysis.
Impact of PEF and thermal processing on apple juice shelf life
Torkamani, AE
2011-01-01
Background and Objectives Pulsed electric field (PEF) is a novel emerging technology which is believed to have the potential to substitute conventional thermal pasteurization (HTST). In the current study PEF was compared with HTST based on microbial inactivation and quality attributes. Materials and Methods Juice was prepared by extracting it from Semirum apples. They were chilled to 4°C over night. Then were divided into two lots, one was treated by PEF and the other by HTST. The treated juices were cultured on tryphtic soy broth (TSB) and results were recorded for 168 days. Quality changes were characterized by color and sensory test. Color changes were quantified using Hunter Lab equipment and equation. Sensory changes were evaluated by test panelists. Results: Using selective media E. Coli was enumerated, the total count of the organism was noticeably lower than PEF treated specimen and after 168. The count didn't reach the initial population. Whereas in PEF treated juice bacterial count bounced back to the initial count and exceeds. Results from Hunter Lab indicated a of 3.04 and 3.08 system for PEF and HTST treated juices. Sensory panel showed that PEF is superior to thermal treatment. Conclusion The study indicated HTST is more suitable based on food safety encounters. However PEF treated are closer to fresh juices based on quality factors. It can be concluded that PEF has the potential to become a suitable replacement to conventional process if improvements in design are applied. PMID:22347599
NASA Astrophysics Data System (ADS)
Hapugoda, J. C.; Sooriyarachchi, M. R.
2017-09-01
Survival time of patients with a disease and the incidence of that particular disease (count) is frequently observed in medical studies with the data of a clustered nature. In many cases, though, the survival times and the count can be correlated in a way that, diseases that occur rarely could have shorter survival times or vice versa. Due to this fact, joint modelling of these two variables will provide interesting and certainly improved results than modelling these separately. Authors have previously proposed a methodology using Generalized Linear Mixed Models (GLMM) by joining the Discrete Time Hazard model with the Poisson Regression model to jointly model survival and count model. As Aritificial Neural Network (ANN) has become a most powerful computational tool to model complex non-linear systems, it was proposed to develop a new joint model of survival and count of Dengue patients of Sri Lanka by using that approach. Thus, the objective of this study is to develop a model using ANN approach and compare the results with the previously developed GLMM model. As the response variables are continuous in nature, Generalized Regression Neural Network (GRNN) approach was adopted to model the data. To compare the model fit, measures such as root mean square error (RMSE), absolute mean error (AME) and correlation coefficient (R) were used. The measures indicate the GRNN model fits the data better than the GLMM model.
Limberg, Brian J; Johnstone, Kevin; Filloon, Thomas; Catrenich, Carl
2016-09-01
Using United States Pharmacopeia-National Formulary (USP-NF) general method <1223> guidance, the Soleris(®) automated system and reagents (Nonfermenting Total Viable Count for bacteria and Direct Yeast and Mold for yeast and mold) were validated, using a performance equivalence approach, as an alternative to plate counting for total microbial content analysis using five representative microbes: Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Candida albicans, and Aspergillus brasiliensis. Detection times (DTs) in the alternative automated system were linearly correlated to CFU/sample (R(2) = 0.94-0.97) with ≥70% accuracy per USP General Chapter <1223> guidance. The LOD and LOQ of the automated system were statistically similar to the traditional plate count method. This system was significantly more precise than plate counting (RSD 1.2-2.9% for DT, 7.8-40.6% for plate counts), was statistically comparable to plate counting with respect to variations in analyst, vial lots, and instruments, and was robust when variations in the operating detection thresholds (dTs; ±2 units) were used. The automated system produced accurate results, was more precise and less labor-intensive, and met or exceeded criteria for a valid alternative quantitative method, consistent with USP-NF general method <1223> guidance.
Real-time passenger counting by active linear cameras
NASA Astrophysics Data System (ADS)
Khoudour, Louahdi; Duvieubourg, Luc; Deparis, Jean-Pierre
1996-03-01
The companies operating subways are very much concerned with counting the passengers traveling through their transport systems. One of the most widely used systems for counting passengers consists of a mechanical gate equipped with a counter. However, such simple systems are not able to count passengers jumping above the gates. Moreover, passengers carrying large luggage or bags may meet some difficulties when going through such gates. The ideal solution is a contact-free counting system that would bring more comfort of use for the passengers. For these reasons, we propose to use a video processing system instead of these mechanical gates. The optical sensors discussed in this paper offer several advantages including well defined detection areas, fast response time and reliable counting capability. A new technology has been developed and tested, based on linear cameras. Preliminary results show that this system is very efficient when the passengers crossing the optical gate are well separated. In other cases, such as in compact crowd conditions, reasonable accuracy has been demonstrated. These results are illustrated by means of a number of sequences shot in field conditions. It is our belief that more precise measurements could be achieved, in the case of compact crowd, by other algorithms and acquisition techniques of the line images that we are presently developing.
Aguzzi, Jacopo; Costa, Corrado; Robert, Katleen; Matabos, Marjolaine; Antonucci, Francesca; Juniper, S. Kim; Menesatti, Paolo
2011-01-01
The development and deployment of sensors for undersea cabled observatories is presently biased toward the measurement of habitat variables, while sensor technologies for biological community characterization through species identification and individual counting are less common. The VENUS cabled multisensory network (Vancouver Island, Canada) deploys seafloor camera systems at several sites. Our objective in this study was to implement new automated image analysis protocols for the recognition and counting of benthic decapods (i.e., the galatheid squat lobster, Munida quadrispina), as well as for the evaluation of changes in bacterial mat coverage (i.e., Beggiatoa spp.), using a camera deployed in Saanich Inlet (103 m depth). For the counting of Munida we remotely acquired 100 digital photos at hourly intervals from 2 to 6 December 2009. In the case of bacterial mat coverage estimation, images were taken from 2 to 8 December 2009 at the same time frequency. The automated image analysis protocols for both study cases were created in MatLab 7.1. Automation for Munida counting incorporated the combination of both filtering and background correction (Median- and Top-Hat Filters) with Euclidean Distances (ED) on Red-Green-Blue (RGB) channels. The Scale-Invariant Feature Transform (SIFT) features and Fourier Descriptors (FD) of tracked objects were then extracted. Animal classifications were carried out with the tools of morphometric multivariate statistic (i.e., Partial Least Square Discriminant Analysis; PLSDA) on Mean RGB (RGBv) value for each object and Fourier Descriptors (RGBv+FD) matrices plus SIFT and ED. The SIFT approach returned the better results. Higher percentages of images were correctly classified and lower misclassification errors (an animal is present but not detected) occurred. In contrast, RGBv+FD and ED resulted in a high incidence of records being generated for non-present animals. Bacterial mat coverage was estimated in terms of Percent Coverage and Fractal Dimension. A constant Region of Interest (ROI) was defined and background extraction by a Gaussian Blurring Filter was performed. Image subtraction within ROI was followed by the sum of the RGB channels matrices. Percent Coverage was calculated on the resulting image. Fractal Dimension was estimated using the box-counting method. The images were then resized to a dimension in pixels equal to a power of 2, allowing subdivision into sub-multiple quadrants. In comparisons of manual and automated Percent Coverage and Fractal Dimension estimates, the former showed an overestimation tendency for both parameters. The primary limitations on the automatic analysis of benthic images were habitat variations in sediment texture and water column turbidity. The application of filters for background corrections is a required preliminary step for the efficient recognition of animals and bacterial mat patches. PMID:22346657
Counting-loss correction for X-ray spectroscopy using unit impulse pulse shaping.
Hong, Xu; Zhou, Jianbin; Ni, Shijun; Ma, Yingjie; Yao, Jianfeng; Zhou, Wei; Liu, Yi; Wang, Min
2018-03-01
High-precision measurement of X-ray spectra is affected by the statistical fluctuation of the X-ray beam under low-counting-rate conditions. It is also limited by counting loss resulting from the dead-time of the system and pile-up pulse effects, especially in a high-counting-rate environment. In this paper a detection system based on a FAST-SDD detector and a new kind of unit impulse pulse-shaping method is presented, for counting-loss correction in X-ray spectroscopy. The unit impulse pulse-shaping method is evolved by inverse deviation of the pulse from a reset-type preamplifier and a C-R shaper. It is applied to obtain the true incoming rate of the system based on a general fast-slow channel processing model. The pulses in the fast channel are shaped to unit impulse pulse shape which possesses small width and no undershoot. The counting rate in the fast channel is corrected by evaluating the dead-time of the fast channel before it is used to correct the counting loss in the slow channel.
NASA Technical Reports Server (NTRS)
Herzfeld, Ute Christina; McDonald, Brian W.; Neumann, Thomas Allen; Wallin, Bruce F.; Neumann, Thomas A.; Markus, Thorsten; Brenner, Anita; Field, Christopher
2014-01-01
NASA's Ice, Cloud and Land Elevation Satellite-II (ICESat-2) mission is a decadal survey mission (2016 launch). The mission objectives are to measure land ice elevation, sea ice freeboard, and changes in these variables, as well as to collect measurements over vegetation to facilitate canopy height determination. Two innovative components will characterize the ICESat-2 lidar: 1) collection of elevation data by a multibeam system and 2) application of micropulse lidar (photon-counting) technology. A photon-counting altimeter yields clouds of discrete points, resulting from returns of individual photons, and hence new data analysis techniques are required for elevation determination and association of the returned points to reflectors of interest. The objective of this paper is to derive an algorithm that allows detection of ground under dense canopy and identification of ground and canopy levels in simulated ICESat-2 data, based on airborne observations with a Sigma Space micropulse lidar. The mathematical algorithm uses spatial statistical and discrete mathematical concepts, including radial basis functions, density measures, geometrical anisotropy, eigenvectors, and geostatistical classification parameters and hyperparameters. Validation shows that ground and canopy elevation, and hence canopy height, can be expected to be observable with high accuracy by ICESat-2 for all expected beam energies considered for instrument design (93.01%-99.57% correctly selected points for a beam with expected return of 0.93 mean signals per shot (msp), and 72.85%-98.68% for 0.48 msp). The algorithm derived here is generally applicable for elevation determination from photoncounting lidar altimeter data collected over forested areas, land ice, sea ice, and land surfaces, as well as for cloud detection.
Extending unbiased stereology of brain ultrastructure to three-dimensional volumes
NASA Technical Reports Server (NTRS)
Fiala, J. C.; Harris, K. M.; Koslow, S. H. (Principal Investigator)
2001-01-01
OBJECTIVE: Analysis of brain ultrastructure is needed to reveal how neurons communicate with one another via synapses and how disease processes alter this communication. In the past, such analyses have usually been based on single or paired sections obtained by electron microscopy. Reconstruction from multiple serial sections provides a much needed, richer representation of the three-dimensional organization of the brain. This paper introduces a new reconstruction system and new methods for analyzing in three dimensions the location and ultrastructure of neuronal components, such as synapses, which are distributed non-randomly throughout the brain. DESIGN AND MEASUREMENTS: Volumes are reconstructed by defining transformations that align the entire area of adjacent sections. Whole-field alignment requires rotation, translation, skew, scaling, and second-order nonlinear deformations. Such transformations are implemented by a linear combination of bivariate polynomials. Computer software for generating transformations based on user input is described. Stereological techniques for assessing structural distributions in reconstructed volumes are the unbiased bricking, disector, unbiased ratio, and per-length counting techniques. A new general method, the fractional counter, is also described. This unbiased technique relies on the counting of fractions of objects contained in a test volume. A volume of brain tissue from stratum radiatum of hippocampal area CA1 is reconstructed and analyzed for synaptic density to demonstrate and compare the techniques. RESULTS AND CONCLUSIONS: Reconstruction makes practicable volume-oriented analysis of ultrastructure using such techniques as the unbiased bricking and fractional counter methods. These analysis methods are less sensitive to the section-to-section variations in counts and section thickness, factors that contribute to the inaccuracy of other stereological methods. In addition, volume reconstruction facilitates visualization and modeling of structures and analysis of three-dimensional relationships such as synaptic connectivity.
Gunnison sage-grouse lek site suitability modeling
Ouren, Douglas S.; Ignizio, Drew A.; Siders, Melissa; Childers, Theresa; Tucker, Karen; Seward, Nathan
2014-01-01
In order to better understand and protect species with minimal or decreasing populations, it is imperative to determine their actual existing population size. The focal species for this project is the Gunnison sage-grouse (GUSG), which became a proposed endangered species under the Endangered Species Act, thus confirming the need for better population estimates. Lek site counting during mating season has historically been the primary method for estimating population size since the grouse are very difficult to count at other times of the year. The objective of this project was to use historical data and available technology to identify additional potential lekking sites. This was done by determining areas throughout the study area that have the same landscape characteristics as those where known lekking activities occur. More accurate population counts could be the outcome of locating more lek sites. One of the remaining seven GUSG populations, the Crawford population (estimated at 128 individuals) exists in an area that includes the Gunnison Gorge National Conservation Area and the northern portion of the Black Canyon of the Gunnison National Park (our study area). While the Crawford population is small, it is still considered a self-sustaining population; the persistence and growth of this population directly contribute to genetic diversity conservation of this declining species. To date, only observational and anecdotal information about the Crawford population’s range, movements, and seasonal habitat use exist. From 1978 to the present, GUSG population monitoring has been accomplished through annual lek counts conducted each spring during GUSG mating season. Although this method has provided information on GUSG population trends, it is somewhat limited because counts are based only on known lekking sites and historically minimal efforts have been made to identify additional lek sites. To meet the objective of locating more potential lekking sites, we used a suite of spatial data, geographic information system tools, and maximum entropy species distribution tools. Based on expert knowledge and landscape variables, the modeling process evolved into a hybrid approach for delineating areas that would have a significant probability for supporting GUSG lekking activities. Based on model results, a sampling protocol was developed for model verification. The results of this project provide wildlife managers with a more sophisticated methodology to evaluate GUSG habitat for potential lekking sites.
A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.
Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi
2010-04-01
The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shinohara, K., E-mail: shinohara.koji@jaea.go.jp; Ochiai, K.; Sukegawa, A.
In order to increase the count rate capability of a neutron detection system as a whole, we propose a multi-stage neutron detection system. Experiments to test the effectiveness of this concept were carried out on Fusion Neutronics Source. Comparing four configurations of alignment, it was found that the influence of an anterior stage on a posterior stage was negligible for the pulse height distribution. The two-stage system using 25 mm thickness scintillator was about 1.65 times the count rate capability of a single detector system for d-D neutrons and was about 1.8 times the count rate capability for d-T neutrons.more » The results suggested that the concept of a multi-stage detection system will work in practice.« less
Quantifying oral inflammatory load: oral neutrophil counts in periodontal health and disease.
Landzberg, M; Doering, H; Aboodi, G M; Tenenbaum, H C; Glogauer, M
2015-06-01
Neutrophils are the primary white blood cells that are recruited to fight the initial phases of microbial infections. While healthy norms have been determined for circulating blood neutrophil counts in order to identify patients with suspected systemic infections, the levels of oral neutrophils (oPMNs) in oral health and in the presence of periodontal diseases have not been described. It is important to address this deficiency in our knowledge as neutrophils are the primary immune cell present in the crevicular fluid and oral environment and previous work has suggested that they may be good indicators of overall oral inflammation and periodontal disease severity. The objective of this study was to measure oPMN counts obtained in a standardized oral rinse from healthy patients and from those with chronic periodontal disease in order to determine if oPMN levels have clinical relevance as markers of periodontal inflammation. A parallel goal of this investigation was to introduce the concept of 'oral inflammatory load', which constitutes the inflammatory burden experienced by the body as a consequence of oral inflammatory disease. Periodontal examinations of patients with a healthy periodontium and chronic periodontal disease were performed (n = 124). Two standardized consecutive saline rinses of 30 s each were collected before patient examination and instrumentation. Neutrophils were quantified in the rinse samples and correlated with the clinical parameters and periodontal diagnosis. Average oPMN counts were determined for healthy patients and for those with mild, moderate and severe chronic periodontal diseases. A statistically significant correlation was found between oPMN counts and deep periodontal probing, sites with bleeding on probing and overall severity of periodontal disease. oPMN counts obtained through a 30-s oral rinse are a good marker of oral inflammatory load and correlate with measures of periodontal disease severity. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Multiplicity counting from fission detector signals with time delay effects
NASA Astrophysics Data System (ADS)
Nagy, L.; Pázsit, I.; Pál, L.
2018-03-01
In recent work, we have developed the theory of using the first three auto- and joint central moments of the currents of up to three fission chambers to extract the singles, doubles and triples count rates of traditional multiplicity counting (Pázsit and Pál, 2016; Pázsit et al., 2016). The objective is to elaborate a method for determining the fissile mass, neutron multiplication, and (α, n) neutron emission rate of an unknown assembly of fissile material from the statistics of the fission chamber signals, analogous to the traditional multiplicity counting methods with detectors in the pulse mode. Such a method would be an alternative to He-3 detector systems, which would be free from the dead time problems that would be encountered in high counting rate applications, for example the assay of spent nuclear fuel. A significant restriction of our previous work was that all neutrons born in a source event (spontaneous fission) were assumed to be detected simultaneously, which is not fulfilled in reality. In the present work, this restriction is eliminated, by assuming an independent, identically distributed random time delay for all neutrons arising from one source event. Expressions are derived for the same auto- and joint central moments of the detector current(s) as in the previous case, expressed with the singles, doubles, and triples (S, D and T) count rates. It is shown that if the time-dispersion of neutron detections is of the same order of magnitude as the detector pulse width, as they typically are in measurements of fast neutrons, the multiplicity rates can still be extracted from the moments of the detector current, although with more involved calibration factors. The presented formulae, and hence also the performance of the proposed method, are tested by both analytical models of the time delay as well as with numerical simulations. Methods are suggested also for the modification of the method for large time delay effects (for thermalised neutrons).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geist, William H.
2015-12-01
This set of slides begins by giving background and a review of neutron counting; three attributes of a verification item are discussed: 240Pu eff mass; α, the ratio of (α,n) neutrons to spontaneous fission neutrons; and leakage multiplication. It then takes up neutron detector systems – theory & concepts (coincidence counting, moderation, die-away time); detector systems – some important details (deadtime, corrections); introduction to multiplicity counting; multiplicity electronics and example distributions; singles, doubles, and triples from measured multiplicity distributions; and the point model: multiplicity mathematics.
Advantages and challenges in automated apatite fission track counting
NASA Astrophysics Data System (ADS)
Enkelmann, E.; Ehlers, T. A.
2012-04-01
Fission track thermochronometer data are often a core element of modern tectonic and denudation studies. Soon after the development of the fission track methods interest emerged for the developed an automated counting procedure to replace the time consuming labor of counting fission tracks under the microscope. Automated track counting became feasible in recent years with increasing improvements in computer software and hardware. One such example used in this study is the commercial automated fission track counting procedure from Autoscan Systems Pty that has been highlighted through several venues. We conducted experiments that are designed to reliably and consistently test the ability of this fully automated counting system to recognize fission tracks in apatite and a muscovite external detector. Fission tracks were analyzed in samples with a step-wise increase in sample complexity. The first set of experiments used a large (mm-size) slice of Durango apatite cut parallel to the prism plane. Second, samples with 80-200 μm large apatite grains of Fish Canyon Tuff were analyzed. This second sample set is characterized by complexities often found in apatites in different rock types. In addition to the automated counting procedure, the same samples were also analyzed using conventional counting procedures. We found for all samples that the fully automated fission track counting procedure using the Autoscan System yields a larger scatter in the fission track densities measured compared to conventional (manual) track counting. This scatter typically resulted from the false identification of tracks due surface and mineralogical defects, regardless of the image filtering procedure used. Large differences between track densities analyzed with the automated counting persisted between different grains analyzed in one sample as well as between different samples. As a result of these differences a manual correction of the fully automated fission track counts is necessary for each individual surface area and grain counted. This manual correction procedure significantly increases (up to four times) the time required to analyze a sample with the automated counting procedure compared to the conventional approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Windhorst, Rogier A.; Cohen, Seth H.; Mechtley, Matt
2011-04-01
We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the Great Observatories Origins Deep Survey (GOODS) South field. The new WFC3 ERS data provide calibrated, drizzled mosaics in the UV filters F225W, F275W, and F336W, as well as in the near-IR filters F098M (Y{sub s} ), F125W (J), and F160W (H) with 1-2 HST orbits per filter. Together with the existing HST Advanced Camera for Surveys (ACS) GOODS-South mosaics in the BViz filters, these panchromatic 10-band ERS data cover 40-50 arcmin{sup 2} at 0.2-1.7 {mu}m in wavelength at 0.''07-0.''15 FWHM resolutionmore » and 0.''090 Multidrizzled pixels to depths of AB {approx_equal} 26.0-27.0 mag (5{sigma}) for point sources, and AB {approx_equal} 25.5-26.5 mag for compact galaxies. In this paper, we describe (1) the scientific rationale, and the data taking plus reduction procedures of the panchromatic 10-band ERS mosaics, (2) the procedure of generating object catalogs across the 10 different ERS filters, and the specific star-galaxy separation techniques used, and (3) the reliability and completeness of the object catalogs from the WFC3 ERS mosaics. The excellent 0.''07-0.''15 FWHM resolution of HST/WFC3 and ACS makes star-galaxy separation straightforward over a factor of 10 in wavelength to AB {approx_equal} 25-26 mag from the UV to the near-IR, respectively. Our main results are: (1) proper motion of faint ERS stars is detected over 6 years at 3.06 {+-} 0.66 mas year{sup -1} (4.6{sigma}), consistent with Galactic structure models; (2) both the Galactic star counts and the galaxy counts show mild but significant trends of decreasing count slopes from the mid-UV to the near-IR over a factor of 10 in wavelength; (3) combining the 10-band ERS counts with the panchromatic Galaxy and Mass Assembly survey counts at the bright end (10 mag {approx}< AB {approx}< 20 mag) and the Hubble Ultra Deep Field counts in the BVizY{sub s}JH filters at the faint end (24 mag {approx}< AB {approx}< 30 mag) yields galaxy counts that are well measured over the entire flux range 10 mag {approx}< AB {approx}< 30 mag for 0.2-2 {mu}m in wavelength; (4) simple luminosity+density evolution models can fit the galaxy counts over this entire flux range. However, no single model can explain the counts over this entire flux range in all 10 filters simultaneously. More sophisticated models of galaxy assembly are needed to reproduce the overall constraints provided by the current panchromatic galaxy counts for 10 mag {approx}< AB {approx}< 30 mag over a factor of 10 in wavelength.« less
Testing the system detection unit for measuring solid minerals bulk density
NASA Astrophysics Data System (ADS)
Voytyuk, I. N.; Kopteva, A. V.
2017-10-01
The paper provides a brief description of the system for measuring flux per volume of solid minerals via example of mineral coal. The paper discloses the operational principle of the detection unit. The paper provides full description of testing methodology, as well as practical implementation of the detection unit testing. This paper describes the removal of two data arrays via the channel of scattered anddirect radiation for the detection units of two generations. This paper describes Matlab software to determine the statistical characteristics of the studied objects. The mean value of pulses per cycles, and pulse counting inaccuracy relatively the mean value were determined for the calculation of the stability account of the detection units.
Linear operating region in the ozone dial photon counting system
NASA Technical Reports Server (NTRS)
Andrawis, Madeleine
1995-01-01
Ozone is a relatively unstable molecule found in Earth's atmosphere. An ozone molecule is made up of three atoms of oxygen. Depending on where ozone resides, it can protect or harm life on Earth. High in the atmosphere, about 15 miles up, ozone acts as a shield to protect Earth's surface from the sun's harmful ultraviolet radiation. Without this shield, we would be more susceptible to skin cancer, cataracts, and impaired immune systems. Closer to Earth, in the air we breathe, ozone is a harmful pollutant that causes damage to lung tissue and plants. Since the early 1980's, airborne lidar systems have been used for making measurements of ozone. The differential absorption lidar (DIAL) technique is used in the remote measurement of O3. This system allows the O3 to be measured as function of the range in the atmosphere. Two frequency-doubled Nd:YAG lasers are used to pump tunable dye lasers. The lasers are operating at 289 nm for the DIAL on-line wavelength of O3, and the other one is operated at 300 nm for the off-line wavelength. The DIAL wavelengths are produced in sequential laser pulses with a time separation of 300 micro s. The backscattered laser energy is collected by telescopes and measured using photon counting systems. The photon counting system measures the light signal by making use of the photon nature of light. The output pulse from the Photo-Multiplier Tube (PE), caused by a photon striking the PMT photo-cathode, is amplified and passed to a pulse height discriminator. The peak value of the pulse is compared to a reference voltage (discrimination level). If the pulse amplitude exceeds the discrimination level, the discriminator generates a standard pulse which is counted by the digital counter. Non-linearity in the system is caused by the overlapping of pulses and the finite response time of the electronics. At low count rates one expects the system to register one event for each output pulse from the PMT corresponding to a photon incident upon the photocathode, however, at higher rates the limitations of the discrimination/counting system will cause the observed count rate to be non-linear with respect to the true count rate. Depending on the pulse height distribution and the discriminator level, the overlapping of pulses (pulse pile-up) can cause count loss or even an additional apparent count gain as the signal levels increase. Characterization of the system, including the pulse height distribution, the signal to noise ratio, and the effect of the discriminator threshold level, is critical in maximizing the linear operating region of the system, thus greatly increasing the useful dynamic range of the system.
Ghislain, Mathilde; Bastard, Jean-Philippe; Meyer, Laurence; Capeau, Jacqueline; Fellahi, Soraya; Gérard, Laurence; May, Thierry; Simon, Anne; Vigouroux, Corinne; Goujard, Cécile
2015-01-01
Objectives HIV-induced immunodeficiency is associated with metabolic abnormalities and systemic inflammation. We investigated the effect of antiretroviral therapy (ART) on restoration of insulin sensitivity, markers of immune activation and inflammation. Methods Immunological, metabolic and inflammatory status was assessed at antiretroviral therapy initiation and three years later in 208 patients from the ANRS-COPANA cohort. Patients were compared according to their pre-ART CD4+ cell count (group 1: ≤ 200/mm3, n = 66 vs. group 2: > 200/mm3, n = 142). Results Median CD4+ cell count increased in both groups after 3 years of successful ART but remained significantly lower in group 1 than in group 2 (404 vs 572 cells/mm3). Triglyceride and insulin levels were higher or tended to be higher in group 1 than in group 2 at ART initiation (median: 1.32 vs 0.97 mmol/l, p = 0.04 and 7.6 vs 6.8 IU, p = 0.09, respectively) and remained higher after three years of ART (1.42 vs 1.16 mmol/L, p = 0.0009 and 8.9 vs 7.2 IU, p = 0.01). After adjustment for individual characteristics and antiretroviral therapy regimens (protease inhibitor (PI), zidovudine), insulin levels remained significantly higher in patients with low baseline CD4+ cell count. Baseline IL-6, sCD14 and sTNFR2 levels were higher in group 1 than in group 2. Most biomarkers of immune activation/inflammation declined during ART, but IL-6 and hsCRP levels remained higher in patients with low baseline CD4+ cell count than in the other patients (median are respectively 1.4 vs 1.1 pg/ml, p = 0.03 and 2.1 vs 1.3 mg/ml, p = 0.07). Conclusion After three years of successful ART, low pretreatment CD4+ T cell count remained associated with elevated insulin, triglyceride, IL-6 and hsCRP levels. These persistent metabolic and inflammatory abnormalities could contribute to an increased risk of cardiovascular and metabolic disease. PMID:26636578
NASA Astrophysics Data System (ADS)
Noroozian, Omid; Barrentine, Emily M.; Stevenson, Thomas R.; Brown, Ari D.; Moseley, Samuel Harvey; Wollack, Edward; Pontoppidan, Klaus Martin; U-Yen, Konpop; Mikula, Vilem
2018-01-01
Photon-counting detectors are highly desirable for reaching the ~ 10-20 W/√Hz power sensitivity permitted by the Origins Space Telescope (OST). We are developing unique Kinetic Inductance Detectors (KIDs) with photon counting capability in the far/mid-IR. Combined with an on-chip far-IR spectrometer onboard OST these detectors will enable a new data set for exploring galaxy evolution and the growth of structure in the Universe. Mid-IR spectroscopic surveys using these detectors will enable mapping the composition of key volatiles in planet-forming material around protoplanetary disks and their evolution into solar systems. While these OST science objectives represent a well-organized community agreement they are impossible to reach without a significant leap forward in detector technology, and the OST is likely not to be recommended if a path to suitable detectors does not exist.To reach the required sensitivity we are experimenting with superconducting resonators made from thin aluminum films on single-crystal silicon substrates. Under the right conditions, small-volume inductors made from these films can become ultra-sensitive to single photons >90 GHz. Understanding the physics of these superconductor-dielectric systems is critical to performance. We achieved a very high quality factor of 0.5 x 106 for a 10-nm Al resonator at n ~ 1 microwave photon drive power, by far the highest value for such thin films in the literature. We measured a residual electron density of < 5 /µm3 and extremely long lifetime of ~ 6.0 ms, both within requirements for photon-counting. To realize an optically coupled device, we are integrating these films with our on-chip spectrometer (μ-Spec) fabrication process. Using a detailed model we simulated the detector when illuminated with randomly arriving photon events. Our results show that photon counting with >95% efficiency at 0.5 - 1.0 THz is achievable.We report on these developments and discuss plans to test in our facility through funding from our recently awarded ROSES-APRA grant and Roman Technology Fellowship award.
Cancer diagnosis using a conventional x-ray fluorescence camera with a cadmium-telluride detector
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Enomoto, Toshiyuki; Hagiwara, Osahiko; Abudurexiti, Abulajiang; Sato, Koetsu; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-10-01
X-ray fluorescence (XRF) analysis is useful for mapping various atoms in objects. Bremsstrahlung X-rays are selected using a 3.0 mm-thick aluminum filter, and these rays are absorbed by indium, cerium and gadolinium atoms in objects. Then XRF is produced from the objects, and photons are detected by a cadmium-telluride detector. The Kα photons are discriminated using a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x-y stage in conjunction with a two-stage controller, and X-ray images obtained by atomic mapping are shown on a personal computer monitor. The scan steps of the x and y axes were both 2.5 mm, and the photon-counting time per mapping point was 0.5 s. We carried out atomic mapping using the X-ray camera, and Kα photons from cerium and gadolinium atoms were produced from cancerous regions in nude mice.
NASA Astrophysics Data System (ADS)
Enomoto, Toshiyuki; Sato, Eiichi; Abderyim, Purkhet; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Watanabe, Manabu; Nagao, Jiro; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-04-01
X-ray fluorescence (XRF) analysis is useful for mapping various molecules in objects. Bremsstrahlung X-rays are selected using a 3.0-mm-thick aluminum filter, and these rays are absorbed by iodine, cerium, and gadolinium molecules in objects. Next, XRF is produced from the objects, and photons are detected by a cadmium-telluride detector. The Kα photons are discriminated using a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x- y stage in conjunction with a two-stage controller, and X-ray images obtained by molecular mapping are shown on a personal computer monitor. The scan steps of x and y axes were both 2.5 mm, and the photon-counting time per mapping point was 0.5 s. We carried out molecular mapping using the X-ray camera, and Kα photons from cerium and gadolinium molecules were produced from cancerous regions in nude mice.
Tian, Guo-Liang; Li, Hui-Qiong
2017-08-01
Some existing confidence interval methods and hypothesis testing methods in the analysis of a contingency table with incomplete observations in both margins entirely depend on an underlying assumption that the sampling distribution of the observed counts is a product of independent multinomial/binomial distributions for complete and incomplete counts. However, it can be shown that this independency assumption is incorrect and can result in unreliable conclusions because of the under-estimation of the uncertainty. Therefore, the first objective of this paper is to derive the valid joint sampling distribution of the observed counts in a contingency table with incomplete observations in both margins. The second objective is to provide a new framework for analyzing incomplete contingency tables based on the derived joint sampling distribution of the observed counts by developing a Fisher scoring algorithm to calculate maximum likelihood estimates of parameters of interest, the bootstrap confidence interval methods, and the bootstrap testing hypothesis methods. We compare the differences between the valid sampling distribution and the sampling distribution under the independency assumption. Simulation studies showed that average/expected confidence-interval widths of parameters based on the sampling distribution under the independency assumption are shorter than those based on the new sampling distribution, yielding unrealistic results. A real data set is analyzed to illustrate the application of the new sampling distribution for incomplete contingency tables and the analysis results again confirm the conclusions obtained from the simulation studies.
Event-related potential correlates of mindfulness meditation competence
Atchley, Rachel; Klee, Dan; Memmott, Tabatha; Goodrich, Elena; Wahbeh, Helané; Oken, Barry
2016-01-01
Objective This cross-sectional study evaluated event-related potentials (ERPs) across three groups: naïve, novice, and experienced meditators as potential physiological markers of mindfulness meditation competence. Methods Electroencephalographic (EEG) data was collected during a target tone detection task and a Breath Counting task. The Breath Counting task served as the mindfulness meditation condition for the novice and experienced meditator groups. Participants were instructed to respond to target tones with a button press in the first task (Tones), and then ignore the primed tones while breath counting. The primary outcomes were ERP responses to target tones, namely the N2 and P3, as markers of stimulus discrimination and attention, respectively. Results As expected, P3 amplitudes elicited by target tones were attenuated within groups during the Breath Counting task in comparison to the Tones task (p < .001). There was a task by group interaction for P3 (p = .039). Both meditator groups displayed greater change in peak-to-trough P3 amplitudes, with higher amplitudes during the Tones condition and more pronounced reductions in P3 amplitudes during the Breath Counting meditation task in comparison to the naïve group. Conclusions Meditators had stronger P3 amplitude responses to target tones when instructed to attend to the tones, and a greater attenuation of P3 amplitudes when instructed to ignore the same tones during the Breath Counting task. This study introduces the idea of identifying ERP markers as a means of measuring mindfulness meditation competence, and results suggest this may be a valid approach. This information has the potential to improve mindfulness meditation interventions by allowing objective assessment of mindfulness meditation quality. PMID:26850995
Owen, Christopher G; Nightingale, Claire M; Rudnicka, Alicja R; Cook, Derek G; Ekelund, Ulf; Whincup, Peter H
2009-08-01
Ethnic differences in physical activity in children in the UK have not been accurately assessed. We made objective measurements of physical activity in 9-10-year-old British children of South Asian, black African-Caribbean and white European origin. Cross-sectional study of urban primary school children (2006-07). Actigraph-GT1M activity monitors were worn by 2071 children during waking hours on at least 1 full day. Ethnic differences in mean daily activity [counts, counts per minute of registered time (CPM) and steps] were adjusted for age, gender, day of week and month. Multilevel modelling allowed for repeated days within individual and clustering within school. In white Europeans, mean daily counts, CPM and mean daily steps were 394,785, 498 and 10,220, respectively. South Asian and black Caribbean children recorded more registered time per day than white Europeans (34 and 36 min, respectively). Compared with white Europeans, South Asians recorded 18 789 fewer counts [95% confidence interval (CI) 6390-31 187], 41 fewer CPM 95% CI 26-57) and 905 fewer steps (95% CI 624-1187). Black African-Caribbeans recorded 25 359 more counts (95% CI 14 273-36 445), and similar CPM, but fewer steps than white Europeans. Girls recorded less activity than boys in all ethnic groups, with 74 782 fewer counts (95% CI 66 665-82 899), 84 fewer CPM (95% CI 74-95) and 1484 fewer steps (95% CI 1301-1668). British South Asian children have lower objectively measured physical activity levels than European whites and black African-Caribbeans.
Tschentscher, Nadja; Hauk, Olaf; Fischer, Martin H; Pulvermüller, Friedemann
2012-02-15
The embodied cognition framework suggests that neural systems for perception and action are engaged during higher cognitive processes. In an event-related fMRI study, we tested this claim for the abstract domain of numerical symbol processing: is the human cortical motor system part of the representation of numbers, and is organization of numerical knowledge influenced by individual finger counting habits? Developmental studies suggest a link between numerals and finger counting habits due to the acquisition of numerical skills through finger counting in childhood. In the present study, digits 1 to 9 and the corresponding number words were presented visually to adults with different finger counting habits, i.e. left- and right-starters who reported that they usually start counting small numbers with their left and right hand, respectively. Despite the absence of overt hand movements, the hemisphere contralateral to the hand used for counting small numbers was activated when small numbers were presented. The correspondence between finger counting habits and hemispheric motor activation is consistent with an intrinsic functional link between finger counting and number processing. Copyright © 2011 Elsevier Inc. All rights reserved.
Development of a stained cell nuclei counting system
NASA Astrophysics Data System (ADS)
Timilsina, Niranjan; Moffatt, Christopher; Okada, Kazunori
2011-03-01
This paper presents a novel cell counting system which exploits the Fast Radial Symmetry Transformation (FRST) algorithm [1]. The driving force behind our system is a research on neurogenesis in the intact nervous system of Manduca Sexta or the Tobacco Hornworm, which was being studied to assess the impact of age, food and environment on neurogenesis. The varying thickness of the intact nervous system in this species often yields images with inhomogeneous background and inconsistencies such as varying illumination, variable contrast, and irregular cell size. For automated counting, such inhomogeneity and inconsistencies must be addressed, which no existing work has done successfully. Thus, our goal is to devise a new cell counting algorithm for the images with non-uniform background. Our solution adapts FRST: a computer vision algorithm which is designed to detect points of interest on circular regions such as human eyes. This algorithm enhances the occurrences of the stained-cell nuclei in 2D digital images and negates the problems caused by their inhomogeneity. Besides FRST, our algorithm employs standard image processing methods, such as mathematical morphology and connected component analysis. We have evaluated the developed cell counting system with fourteen digital images of Tobacco Hornworm's nervous system collected for this study with ground-truth cell counts by biology experts. Experimental results show that our system has a minimum error of 1.41% and mean error of 16.68% which is at least forty-four percent better than the algorithm without FRST.
Real-time video analysis for retail stores
NASA Astrophysics Data System (ADS)
Hassan, Ehtesham; Maurya, Avinash K.
2015-03-01
With the advancement in video processing technologies, we can capture subtle human responses in a retail store environment which play decisive role in the store management. In this paper, we present a novel surveillance video based analytic system for retail stores targeting localized and global traffic estimate. Development of an intelligent system for human traffic estimation in real-life poses a challenging problem because of the variation and noise involved. In this direction, we begin with a novel human tracking system by an intelligent combination of motion based and image level object detection. We demonstrate the initial evaluation of this approach on available standard dataset yielding promising result. Exact traffic estimate in a retail store require correct separation of customers from service providers. We present a role based human classification framework using Gaussian mixture model for this task. A novel feature descriptor named graded colour histogram is defined for object representation. Using, our role based human classification and tracking system, we have defined a novel computationally efficient framework for two types of analytics generation i.e., region specific people count and dwell-time estimation. This system has been extensively evaluated and tested on four hours of real-life video captured from a retail store.
Tracking Steps on Apple Watch at Different Walking Speeds.
Veerabhadrappa, Praveen; Moran, Matthew Duffy; Renninger, Mitchell D; Rhudy, Matthew B; Dreisbach, Scott B; Gift, Kristin M
2018-04-09
QUESTION: How accurate are the step counts obtained from Apple Watch? In this validation study, video steps vs. Apple Watch steps (mean ± SD) were 2965 ± 144 vs. 2964 ± 145 steps; P < 0.001. Lin's concordance correlation coefficient showed a strong correlation (r = 0.96; P < 0.001) between the two measurements. There was a total error of 0.034% (1.07 steps) for the Apple Watch steps when compared with the manual counts obtained from video recordings. Our study is one of the initial studies to objectively validate the accuracy of the step counts obtained from Apple watch at different walking speeds. Apple Watch tested to be an extremely accurate device for measuring daily step counts for adults.
Effect of Cypermethrin on the Growth of Ciliate Protozoan Paramecium caudatum
Dutta, Joydeep
2015-01-01
Objective: The objective of this study is to assess the effect of cypermethrin on the growth of ciliate protozoan Paramecium caudatum. Materials and Methods: Monoxenic culture of P. caudatum, were exposed to different doses (0.01, 0.05, 0.1, 0.15, and 0.2 µg/L) of cypermethrin along with control for 24, 48, 72, and 96 h time interval. The total numbers of live and dead cells were counted after trypan blue staining in Neubauer hemocytometer. Results: Marked decrease in the number of living cells with the increase in the concentration of cypermethrin and with increasing exposure time intervals was recorded. Conclusion: The results indicate that cypermethrin is toxic to P. caudatum even at low concentrations when it enters in the aquatic system through runoff. PMID:26862268
Imai, Eri; Hirai, Kota; Mikami, Yoshiko; Nukaga, Mariko; Enseki, Mayumi; Tabata, Hideyuki; Kato, Masahiko; Mochizuki, Hiroyuki
2017-11-01
Two patients with a chronic, barking cough were diagnosed with psychogenic cough. Using an original cough counter we studied the nocturnal cough count and pattern. While the number of coughs when awake was extremely high for both patients, the number of coughs was remarkably reduced during sleep, similar to an exacerbation of asthma. Moreover, the properties of the coughs when awake were clearly different from those of coughs during sleep. In conclusion, an objective examination using a cough counter was useful for the diagnosis, treatment and management of psychogenic cough. Copyright © 2017 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
York, Jason M.; McDaniel, Allison W.; Blevins, Neil A.; Guillet, Riley R.; Allison, Sarah O.; Cengel, Keith A.; Freund, Gregory G.
2012-01-01
Use of individually ventilated caging (IVC) systems for mouse-based laboratory investigation has dramatically increased. We found that without mice present, intra-cage oxygen concentration was comparable (21%) between IVC housing and ambient environment caging (AEC) that used wire top lids. However, when mice were housed 4-to-a-cage for 1 week, intra-cage oxygen dropped to 20.5% in IVC housing as compared to 21% for AEC housing. IVC intra-cage humidity was also elevated relative to AEC housing. Mice raised in IVC housing as compared to mice raised in AEC housing had higher RBC mass, hematocrit and hemoglobin concentrations. They also had elevated platelet counts but lower white blood cell counts. IVC mice relative to AEC mice had increased saccharin preference and increased fluid consumption but similar locomotion, food intake, social exploration and novel object recognition when tested in an AEC environment. Taken together, these data indicate that ventilated caging systems can have a 0.5% reduction from ambient oxygen concentration that is coupled to mouse red blood cell indices indicative of chronic exposure to a hypoxia. Importantly, IVC housing can impact behavioral testing for depressive-like behavior. PMID:22561683
Pejman, Laleh; Omrani, Hasan; Mirzamohammadi, Zahra; Keyhanmanesh, Rana
2014-01-01
Objective(s): For determining the mechanism of anti-asthmatic effect of thymoquinone, this investigation evaluated the effect of thymoquinone in the presence of selective A2A and A2B adenosine receptor antagonists (ZM241385 and MRS1706, respectively). Materials and Methods: Seventy guinea pigs were randomly divided to 7 groups; control (C), sensitized with ovalbumin (S), sensitized groups pretreated with thymoquinone (S+TQ), ZM241385 (S+Anta A2A), MRS1706 (S+Anta A2B), thymoquinone and antagonists (S+Anta A2A+TQ and S+Anta A2B+TQ). Thymoquinone and each of these antagonists with 3 mg/kg dose were injected i.p. on 10th day of sensitization protocol. Tracheal responsiveness (TR) to methacholine and ovalbumin (OA), and total and differential cell count in lung lavage fluid (LLF) in different groups were measured. Results: Increased EC50 and LLF neutrophil count and decreased TR to methacholine and OA, LLF eosinophil and basophil counts were observed in S+TQ group compared to S group (P<0.001 to P<0.05). Significant decrease in EC50 (P<0.01), LLF neutrophil, lymphocyte and monocyte count (P<0.001 for all) and significant increase in TR to OA (P<0.01), LLF total WBC (P<0.01) and eosinophil count (P<0.001) were observed in S+A2A group compared to S+TQ group. There was significant increase in LLF eosinophil and monocyte counts in S+Anta A2B group compared with S+TQ group (P<0.001 for both). In S+TQ+Anta A2A group, there was significant increase in LLF eosinophil (P<0.001) and significant decrease in LLF neutrophil (P<0.01) and monocyte (P<0.001) counts compared with S+TQ group. Conclusion: Thymoquinone affects adenosine receptors, which suggest that some of its anti-inflammatory effects may be mediated by these receptors. PMID:25859306
Huang, Tao; Gejl, Anne Kær; Froberg, Karsten
2016-01-01
Objectives To examine objectively measured physical activity level, organized sports participation and active commuting to school in relation to mathematic performance and inhibitory control in adolescents. Methods The design was cross-sectional. A convenient sample of 869 sixth and seventh grade students (12–14 years) was invited to participate in the study. A total of 568 students fulfilled the inclusion criteria and comprised the final sample for this study. Mathematic performance was assessed by a customized test and inhibitory control was assessed by a modified Eriksen flanker task. Physical activity was assessed with GT3X and GT3X+ accelerometers presented in sex-specific quartiles of mean counts per minute and mean minutes per day in moderate-to-vigorous physical activity. Active commuting and sports participation was self-reported. Mixed model regression was applied. Total physical activity level was stratified by bicycling status in order to bypass measurement error subject to the accelerometer. Results Non-cyclists in the 2nd quartile of counts per minute displayed a higher mathematic score, so did cyclists in the 2nd and 3rd quartile of moderate-to-vigorous physical activity relative to the least active quartile. Non-cyclists in the 3rd quartile of counts per minute had an improved reaction time and cyclists in the 2nd quartile of counts per minute and moderate-to-vigorous physical activity displayed an improved accuracy, whereas non-cyclists in the 2nd quartile of counts per minute showed an inferior accuracy relative to the least active quartile. Bicycling to school and organized sports participation were positively associated with mathematic performance. Conclusions Sports participation and bicycling were positively associated with mathematic performance. Results regarding objectively measured physical activity were mixed. Although, no linear nor dose-response relationship was observed there was no indication of a higher activity level impairing the scholastic or cognitive performance. PMID:26727211
Local and systemic effects of fibrin and cyanoacrylate adhesives on lung lesions in rabbits
Carvalho, Marcus V.H.; Marchi, Evaldo; Fruchi, Andre J.; Dias, Bruno V.B.; Pinto, Clovis L.; dos Santos, Geovane R.; Acencio, Milena M.P.
2017-01-01
OBJECTIVES: Tissue adhesives can be used to prevent pulmonary air leaks, which frequently occur after lung interventions. The objective of this study is to evaluate local and systemic effects of fibrin and cyanoacrylate tissue adhesives on lung lesions in rabbits. METHODS: Eighteen rabbits were submitted to videothoracoscopy + lung incision alone (control) or videothoracoscopy + lung incision + local application of fibrin or cyanoacrylate adhesive. Blood samples were collected and assessed for leukocyte, neutrophil and lymphocyte counts and interleukin-8 levels preoperatively and at 48 hours and 28 days post-operatively. After 28 days, the animals were euthanized for gross examination of the lung surface, and lung fragments were excised for histopathological analysis. RESULTS: Fibrin and cyanoacrylate produced similar adhesion scores of the lung to the parietal pleura. Microscopic analysis revealed uniform low-cellular tissue infiltration in the fibrin group and an intense tissue reaction characterized by dense inflammatory infiltration of granulocytes, giant cells and necrosis in the cyanoacrylate group. No changes were detected in the leukocyte, neutrophil or lymphocyte count at any time-point, while the interleukin-8 levels were increased in the fibrin and cyanoacrylate groups after 48 hours compared with the pre-operative control levels (p<0.01). CONCLUSION: Both adhesive agents promoted normal tissue healing, with a more pronounced local inflammatory reaction observed for cyanoacrylate. Among the serum markers of inflammation, only the interleukin-8 levels changed post-operatively, increasing after 48 hours and decreasing after 28 days to levels similar to those of the control group in both the fibrin and cyanoacrylate groups. PMID:29160425
Bogdanov, Anita; Endrész, Valeria; Urbán, Szabolcs; Lantos, Ildikó; Deák, Judit; Burián, Katalin; Önder, Kamil; Ayaydin, Ferhan; Balázs, Péter
2014-01-01
Chlamydiae are obligate intracellular bacteria that propagate in the inclusion, a specific niche inside the host cell. The standard method for counting chlamydiae is immunofluorescent staining and manual counting of chlamydial inclusions. High- or medium-throughput estimation of the reduction in chlamydial inclusions should be the basis of testing antichlamydial compounds and other drugs that positively or negatively influence chlamydial growth, yet low-throughput manual counting is the common approach. To overcome the time-consuming and subjective manual counting, we developed an automatic inclusion-counting system based on a commercially available DNA chip scanner. Fluorescently labeled inclusions are detected by the scanner, and the image is processed by ChlamyCount, a custom plug-in of the ImageJ software environment. ChlamyCount was able to measure the inclusion counts over a 1-log-unit dynamic range with a high correlation to the theoretical counts. ChlamyCount was capable of accurately determining the MICs of the novel antimicrobial compound PCC00213 and the already known antichlamydial antibiotics moxifloxacin and tetracycline. ChlamyCount was also able to measure the chlamydial growth-altering effect of drugs that influence host-bacterium interaction, such as gamma interferon, DEAE-dextran, and cycloheximide. ChlamyCount is an easily adaptable system for testing antichlamydial antimicrobials and other compounds that influence Chlamydia-host interactions. PMID:24189259
Machine Learning Based Single-Frame Super-Resolution Processing for Lensless Blood Cell Counting
Huang, Xiwei; Jiang, Yu; Liu, Xu; Xu, Hang; Han, Zhi; Rong, Hailong; Yang, Haiping; Yan, Mei; Yu, Hao
2016-01-01
A lensless blood cell counting system integrating microfluidic channel and a complementary metal oxide semiconductor (CMOS) image sensor is a promising technique to miniaturize the conventional optical lens based imaging system for point-of-care testing (POCT). However, such a system has limited resolution, making it imperative to improve resolution from the system-level using super-resolution (SR) processing. Yet, how to improve resolution towards better cell detection and recognition with low cost of processing resources and without degrading system throughput is still a challenge. In this article, two machine learning based single-frame SR processing types are proposed and compared for lensless blood cell counting, namely the Extreme Learning Machine based SR (ELMSR) and Convolutional Neural Network based SR (CNNSR). Moreover, lensless blood cell counting prototypes using commercial CMOS image sensors and custom designed backside-illuminated CMOS image sensors are demonstrated with ELMSR and CNNSR. When one captured low-resolution lensless cell image is input, an improved high-resolution cell image will be output. The experimental results show that the cell resolution is improved by 4×, and CNNSR has 9.5% improvement over the ELMSR on resolution enhancing performance. The cell counting results also match well with a commercial flow cytometer. Such ELMSR and CNNSR therefore have the potential for efficient resolution improvement in lensless blood cell counting systems towards POCT applications. PMID:27827837
Effects of Near-Term Sea-Level Rise on Coastal Infrastructure
2013-03-01
methodology is more objective, and more robust, than the standard methods of counting overwash sand layers or identifying marine microfossils in the...duration thresholds on Atlantic tropical cyclone counts , J. Climate, 23, 2508-2519, doi:10.1175/2009JCLI3034.1. Lane, P., Donnelly, J.P., Woodruff...Holocene Climate in the Northern Great Plains Inferred from Sediment Stratigraphy, Stable Isotopes, Carbonate Geochemistry, Diatoms, and Pollen at Moon
Fast distributed large-pixel-count hologram computation using a GPU cluster.
Pan, Yuechao; Xu, Xuewu; Liang, Xinan
2013-09-10
Large-pixel-count holograms are one essential part for big size holographic three-dimensional (3D) display, but the generation of such holograms is computationally demanding. In order to address this issue, we have built a graphics processing unit (GPU) cluster with 32.5 Tflop/s computing power and implemented distributed hologram computation on it with speed improvement techniques, such as shared memory on GPU, GPU level adaptive load balancing, and node level load distribution. Using these speed improvement techniques on the GPU cluster, we have achieved 71.4 times computation speed increase for 186M-pixel holograms. Furthermore, we have used the approaches of diffraction limits and subdivision of holograms to overcome the GPU memory limit in computing large-pixel-count holograms. 745M-pixel and 1.80G-pixel holograms were computed in 343 and 3326 s, respectively, for more than 2 million object points with RGB colors. Color 3D objects with 1.02M points were successfully reconstructed from 186M-pixel hologram computed in 8.82 s with all the above three speed improvement techniques. It is shown that distributed hologram computation using a GPU cluster is a promising approach to increase the computation speed of large-pixel-count holograms for large size holographic display.
Sharma, Veena; Singh, Manu
2014-01-01
Objectives: Enormous propensity of plants to synthesize a variety of structurally diverse bioactive compounds, has made the plant kingdom a potential source of chemical constituents with various therapeutic values, including antitumor and cytotoxic activities. Blood is a good indicator to determine the physiological and pathological status of man and animal. The objective of the present study is to determine the effect of Operculina turpethum root extract and its isolated glycoside treatment on the hematological parameters in the mice with N-Nitrosodimethylamine (NDMA) induced cancer. Materials and Methods: The body weights of the animals were recorded before and after the experiment. Non-coagulated blood was tested for total erythrocyte count, total leukocyte count, hemoglobin, differential leukocyte count (DLC) and for other blood indices. Results: A significant (P < 0.01), (P < 0.001) recovery of the red blood cell and white blood cell counts, packed cell volume and hemoglobin content in the host after 21 day treatment was shown. Conclusion: These results show that the extract of Operculina turpethum is relatively safe following oral administration and have possible stimulatory effect on red blood cell production and there was dose dependent therapeutic effect. PMID:24748732
Oral Candida colonization and candidiasis in patients with psoriasis.
Bedair, Ahmad A; Darwazeh, Azmi M G; Al-Aboosi, Mustafa M
2012-11-01
The objective of this study was to investigate oral Candida colonization and candidosis in a group of patients with psoriasis and controls. A total of 100 patients with psoriasis and matched controls underwent the concentrated oral rinse test for Candida isolation. Candida species were identified by the VITEK 2 Identification System. Categorical variables were evaluated using the χ(2) test. The median Candida count was compared using the Mann-Whitney U test. Oral candidiasis was diagnosed in 3% of the patients with psoriasis. The Candida count and prevalence were significantly higher in the patients with psoriasis compared with controls (69% vs 44%, P < .001), but with no relationship to the severity or treatment of psoriasis. Oral Candida was significantly higher in late-onset (at age ≥30 years) compared with early-onset psoriasis (at age <30 years). Patients with psoriasis have increased oral Candida colonization and candidiasis. Further studies are needed to clarify the predisposing factor(s) for oral Candida in patients with psoriasis. Copyright © 2012 Elsevier Inc. All rights reserved.
A Prescription for List-Mode Data Processing Conventions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beddingfield, David H.; Swinhoe, Martyn Thomas; Huszti, Jozsef
There are a variety of algorithmic approaches available to process list-mode pulse streams to produce multiplicity histograms for subsequent analysis. In the development of the INCC v6.0 code to include the processing of this data format, we have noted inconsistencies in the “processed time” between the various approaches. The processed time, tp, is the time interval over which the recorded pulses are analyzed to construct multiplicity histograms. This is the time interval that is used to convert measured counts into count rates. The observed inconsistencies in tp impact the reported count rate information and the determination of the error-values associatedmore » with the derived singles, doubles, and triples counting rates. This issue is particularly important in low count-rate environments. In this report we will present a prescription for the processing of list-mode counting data that produces values that are both correct and consistent with traditional shift-register technologies. It is our objective to define conventions for list mode data processing to ensure that the results are physically valid and numerically aligned with the results from shift-register electronics.« less
A matrix-inversion method for gamma-source mapping from gamma-count data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adsley, Ian; Burgess, Claire; Bull, Richard K
In a previous paper it was proposed that a simple matrix inversion method could be used to extract source distributions from gamma-count maps, using simple models to calculate the response matrix. The method was tested using numerically generated count maps. In the present work a 100 kBq Co{sup 60} source has been placed on a gridded surface and the count rate measured using a NaI scintillation detector. The resulting map of gamma counts was used as input to the matrix inversion procedure and the source position recovered. A multi-source array was simulated by superposition of several single-source count maps andmore » the source distribution was again recovered using matrix inversion. The measurements were performed for several detector heights. The effects of uncertainties in source-detector distances on the matrix inversion method are also examined. The results from this work give confidence in the application of the method to practical applications, such as the segregation of highly active objects amongst fuel-element debris. (authors)« less
Mark, Winifred; Dowker, Ann
2015-01-01
The relative linguistic transparency of the Asian counting system has been used to explain Asian students’ relative superiority in cross-cultural comparisons of mathematics achievement. To test the validity and extent of linguistic transparency in accounting for mathematical abilities, this study tested Chinese and British primary school children. Children in Hong Kong can learn mathematics using languages with both regular (Chinese) and irregular (English) counting systems, depending on their schools’ medium of instruction. This makes it possible to compare groups with varying levels of exposure to the regular and irregular number systems within the same educational system, curriculum, and cultural environment. The study included three groups of first/second graders and third/fourth graders with varying degrees of experience to the Chinese language and counting systems: no experience (UK; n = 49); spoke Chinese at home and learnt to count in English at school (HK-E; n = 43); spoke Chinese at home and learnt to count in Chinese at school (HK-C; n = 47). They were compared on counting, numerical abilities and place value representation. The present study also measured nonverbal reasoning, attitude toward mathematics, involvement of parents, and extra-curricular mathematics lessons to explore alternative explanations of children’s numeric ability. Results indicated that students in HK-C were better at counting backward and on the numeric skills test than those in HK-E, who were in turn better than the UK students. However, there was no statistical difference in counting forward, place value understanding, and a measure of arithmetic. Our findings add to existent literature suggesting that linguistic transparency does not have an all-pervasive influence on cross-national differences in arithmetic performance. PMID:25767456
Non-Markovian full counting statistics in quantum dot molecules
Xue, Hai-Bin; Jiao, Hu-Jun; Liang, Jiu-Qing; Liu, Wu-Ming
2015-01-01
Full counting statistics of electron transport is a powerful diagnostic tool for probing the nature of quantum transport beyond what is obtainable from the average current or conductance measurement alone. In particular, the non-Markovian dynamics of quantum dot molecule plays an important role in the nonequilibrium electron tunneling processes. It is thus necessary to understand the non-Markovian full counting statistics in a quantum dot molecule. Here we study the non-Markovian full counting statistics in two typical quantum dot molecules, namely, serially coupled and side-coupled double quantum dots with high quantum coherence in a certain parameter regime. We demonstrate that the non-Markovian effect manifests itself through the quantum coherence of the quantum dot molecule system, and has a significant impact on the full counting statistics in the high quantum-coherent quantum dot molecule system, which depends on the coupling of the quantum dot molecule system with the source and drain electrodes. The results indicated that the influence of the non-Markovian effect on the full counting statistics of electron transport, which should be considered in a high quantum-coherent quantum dot molecule system, can provide a better understanding of electron transport through quantum dot molecules. PMID:25752245
32-channel single photon counting module for ultrasensitive detection of DNA sequences
NASA Astrophysics Data System (ADS)
Gudkov, Georgiy; Dhulla, Vinit; Borodin, Anatoly; Gavrilov, Dmitri; Stepukhovich, Andrey; Tsupryk, Andrey; Gorbovitski, Boris; Gorfinkel, Vera
2006-10-01
We continue our work on the design and implementation of multi-channel single photon detection systems for highly sensitive detection of ultra-weak fluorescence signals, for high-performance, multi-lane DNA sequencing instruments. A fiberized, 32-channel single photon detection (SPD) module based on single photon avalanche diode (SPAD), model C30902S-DTC, from Perkin Elmer Optoelectronics (PKI) has been designed and implemented. Unavailability of high performance, large area SPAD arrays and our desire to design high performance photon counting systems drives us to use individual diodes. Slight modifications in our quenching circuit has doubled the linear range of our system from 1MHz to 2MHz, which is the upper limit for these devices and the maximum saturation count rate has increased to 14 MHz. The detector module comprises of a single board computer PC-104 that enables data visualization, recording, processing, and transfer. Very low dark count (300-1000 counts/s), robust, efficient, simple data collection and processing, ease of connectivity to any other application demanding similar requirements and similar performance results to the best commercially available single photon counting module (SPCM from PKI) are some of the features of this system.
NASA Astrophysics Data System (ADS)
Sato, Eiichi; Abduraxit, Ablajan; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Takahashi, Kiyomi; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2010-04-01
An energy-discrimination K-edge x-ray computed tomography (CT) system is useful for controlling the image contrast of a target region by selecting both the photon energy and the energy width. The CT system has an oscillation-type linear cadmium telluride (CdTe) detectror. CT is performed by repeated linear scans and rotations of an object. Penetrating x-ray photons from the object are detected by a CdTe detector, and event signals of x-ray photons are produced using charge-sensitive and shaping amplifiers. Both photon energy and energy width are selected out using a multichannel analyzer, and the number of photons is counted by a counter card. In energy-discrimination CT, the tube voltage and tube current were 80 kV and 20 μA, respectively, and the x-ray intensity was 1.92 μGy/s at a distance of 1.0 m from the source and a tube voltage of 80 kV. The energy-discrimination CT was carried out by selecting x-ray photon energies.
NASA Astrophysics Data System (ADS)
Takiue, Makoto; Fujii, Haruo; Ishikawa, Hiroaki
1984-12-01
2, 5-diphenyloxazole (PPO) has been proposed as a wavelength shifter for Cherenkov counting. Since PPO is not incorporated with water, we have introduced the fluor into water in the form of micelle using a PPO-ethanol system. This technique makes it possible to obtain a high Cherenkov counting efficiency under stable sample conditions, attributed to the proper spectrometric features of the PPO. The 32P Cherenkov counting efficiency (68.4%) obtained from this technique is large as that measured with a conventional Cherenkov technique.
Protecting count queries in study design.
Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A
2012-01-01
Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.
Hematology of healthy Florida manatees (Trichechus manatus)
Harvey, J.W.; Harr, K.E.; Murphy, D.; Walsh, M.T.; Nolan, E.C.; Bonde, R.K.; Pate, M.G.; Deutsch, C.J.; Edwards, H.H.; Clapp, W.L.
2009-01-01
Background: Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. Objectives: The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Methods: Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Results: Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Conclusions: Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals. ?? 2009 American Society for Veterinary Clinical Pathology.
Ammersbach, Mélanie; Beaufrère, Hugues; Gionet Rollick, Annick; Tully, Thomas
2015-03-01
While hematologic reference intervals (RI) are available for multiple raptorial species of the order Accipitriformes and Falconiformes, there is a lack of valuable hematologic information in Strigiformes that can be used for diagnostic and health monitoring purposes. The objective was to report RI in Strigiformes for hematologic variables and to assess agreement between manual cell counting techniques. A multi-center prospective study was designed to assess hematologic RI and blood cell morphology in owl species. Samples were collected from individuals representing 13 Strigiformes species, including Great Horned Owl, Snowy Owl, Eurasian Eagle Owl, Barred Owl, Great Gray Owl, Ural Owl, Northern Saw-Whet Owls, Northern Hawk Owl, Spectacled Owl, Barn Owl, Eastern Screech Owl, Long-Eared Owl, and Short-Eared Owl. Red blood cell count was determined manually using a hemocytometer. White blood cell count was determined using 3 manual counting techniques: (1) phloxine B technique, (2) Natt and Herrick technique, and (3) estimation from the smear. Differential counts and blood cell morphology were determined on smears. Reference intervals were determined and agreement between methods was calculated. Important species-specific differences were observed in blood cell counts and granulocyte morphology. Differences in WBC count between species did not appear to be predictable based on phylogenetic relationships. Overall, most boreal owl species exhibited a lower WBC count than other species. Important disagreements were found between different manual WBC counting techniques. Disagreements observed between manual counting techniques suggest that technique-specific RI should be used in Strigiformes. © 2015 American Society for Veterinary Clinical Pathology.
Motor run-up system. [power lines
NASA Technical Reports Server (NTRS)
Daeges, J. J. (Inventor)
1975-01-01
A starting system is described for bringing a large synchronous motor up to speed to prevent large power line disturbances at the moment the motor is connected to the power line. The system includes (1) a digital counter which generates a count determined by the difference in frequency between the power line and a small current generated by the synchronous motor; (2) a latch which stores the count; and (3) a comparator which compares the stored count with a newly generated count to determine whether the synchronous motor is accelerating or decelerating. Signals generated by the counter and comparator control the current to a clutch that couples a starting motor to the large synchronous motor.
Weiser, H; Vitz, R C; Moos, H W; Weinstein, A
1976-12-01
An evacuated high transmission prism spectrograph using a microchannel plate detection system with resistive strip readout was flown behind a precision pointing telescope on a sounding rocket. The construction, preparation, flight performance, and calibration stability of the system are discussed. Despite the adverse environmental conditions associated with sounding rocket flights, the microchannel detector system performed well. Far uv spectra (1160-1750 A) of stellar and planetary objects were obtained; spectral features with fluxes as low as 0.06 photons cm(-2) sec(-1) were detectable. This was achieved by operating the plates at lower than normal gains, using sensitive pulse counting electronics with both upper and lower limit discriminators, and maintaining the spectrograph and detector at a pressure of ~10(-6) Torr until reaching altitude.
Classifier-Guided Sampling for Complex Energy System Optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Backlund, Peter B.; Eddy, John P.
2015-09-01
This report documents the results of a Laboratory Directed Research and Development (LDRD) effort enti tled "Classifier - Guided Sampling for Complex Energy System Optimization" that was conducted during FY 2014 and FY 2015. The goal of this proj ect was to develop, implement, and test major improvements to the classifier - guided sampling (CGS) algorithm. CGS is type of evolutionary algorithm for perform ing search and optimization over a set of discrete design variables in the face of one or more objective functions. E xisting evolutionary algorithms, such as genetic algorithms , may require a large number of omore » bjecti ve function evaluations to identify optimal or near - optimal solutions . Reducing the number of evaluations can result in significant time savings, especially if the objective function is computationally expensive. CGS reduce s the evaluation count by us ing a Bayesian network classifier to filter out non - promising candidate designs , prior to evaluation, based on their posterior probabilit ies . In this project, b oth the single - objective and multi - objective version s of the CGS are developed and tested on a set of benchm ark problems. As a domain - specific case study, CGS is used to design a microgrid for use in islanded mode during an extended bulk power grid outage.« less
NASA Astrophysics Data System (ADS)
Hagiwara, Osahiko; Watanabe, Manabu; Sato, Eiichi; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2011-06-01
An X-ray fluorescence computed tomography system (XRF-CT) is useful for determining the main atoms in objects. To detect iodine atoms without using a synchrotron, we developed an XRF-CT system utilizing a cadmium telluride (CdTe) detector and a cerium X-ray generator. CT is performed by repeated linear scans and rotations of an object. When cerium K-series characteristic X-rays are absorbed by iodine atoms in objects, iodine K fluorescence is produced from atoms and is detected by the CdTe detector. Next, event signals of X-ray photons are produced with the use of charge-sensitive and shaping amplifiers. Iodine Kα fluorescence is isolated using a multichannel analyzer, and the number of photons is counted using a counter card. In energy-dispersive XRF-CT, the tube voltage and tube current were 70 kV and 0.40 mA, respectively, and the X-ray intensity was 115.3 μGy/s at a distance of 1.0 m from the source. The demonstration of XRF-CT was carried out by the selection of photons in an energy range from 27.5 to 29.5 keV with a photon-energy resolution of 1.2 keV.
Scare, J A; Slusarewicz, P; Noel, M L; Wielgus, K M; Nielsen, M K
2017-11-30
Fecal egg counts are emphasized for guiding equine helminth parasite control regimens due to the rise of anthelmintic resistance. This, however, poses further challenges, since egg counting results are prone to issues such as operator dependency, method variability, equipment requirements, and time commitment. The use of image analysis software for performing fecal egg counts is promoted in recent studies to reduce the operator dependency associated with manual counts. In an attempt to remove operator dependency associated with current methods, we developed a diagnostic system that utilizes a smartphone and employs image analysis to generate automated egg counts. The aims of this study were (1) to determine precision of the first smartphone prototype, the modified McMaster and ImageJ; (2) to determine precision, accuracy, sensitivity, and specificity of the second smartphone prototype, the modified McMaster, and Mini-FLOTAC techniques. Repeated counts on fecal samples naturally infected with equine strongyle eggs were performed using each technique to evaluate precision. Triplicate counts on 36 egg count negative samples and 36 samples spiked with strongyle eggs at 5, 50, 500, and 1000 eggs per gram were performed using a second smartphone system prototype, Mini-FLOTAC, and McMaster to determine technique accuracy. Precision across the techniques was evaluated using the coefficient of variation. In regards to the first aim of the study, the McMaster technique performed with significantly less variance than the first smartphone prototype and ImageJ (p<0.0001). The smartphone and ImageJ performed with equal variance. In regards to the second aim of the study, the second smartphone system prototype had significantly better precision than the McMaster (p<0.0001) and Mini-FLOTAC (p<0.0001) methods, and the Mini-FLOTAC was significantly more precise than the McMaster (p=0.0228). Mean accuracies for the Mini-FLOTAC, McMaster, and smartphone system were 64.51%, 21.67%, and 32.53%, respectively. The Mini-FLOTAC was significantly more accurate than the McMaster (p<0.0001) and the smartphone system (p<0.0001), while the smartphone and McMaster counts did not have statistically different accuracies. Overall, the smartphone system compared favorably to manual methods with regards to precision, and reasonably with regards to accuracy. With further refinement, this system could become useful in veterinary practice. Copyright © 2017 Elsevier B.V. All rights reserved.
Karulin, Alexey Y; Megyesi, Zoltán; Caspell, Richard; Hanson, Jodi; Lehmann, Paul V
2018-01-01
Over the past decade, ELISPOT has become a highly implemented mainstream assay in immunological research, immune monitoring, and vaccine development. Unique single cell resolution along with high throughput potential sets ELISPOT apart from flow cytometry, ELISA, microarray- and bead-based multiplex assays. The necessity to unambiguously identify individual T and B cells that do, or do not co-express certain analytes, including polyfunctional cytokine producing T cells has stimulated the development of multi-color ELISPOT assays. The success of these assays has also been driven by limited sample/cell availability and resource constraints with reagents and labor. There are few commercially available test kits and instruments available at present for multi-color FLUOROSPOT. Beyond commercial descriptions of competing systems, little is known about their accuracy in experimental settings detecting individual cells that secrete multiple analytes vs. random overlays of spots. Here, we present a theoretical and experimental validation study for three and four color T- and B-cell FLUOROSPOT data analysis. The ImmunoSpot ® Fluoro-X™ analysis system we used includes an automatic image acquisition unit that generates individual color images free of spectral overlaps and multi-color spot counting software based on the maximal allowed distance between centers of spots of different colors or Center of Mass Distance (COMD). Using four color B-cell FLUOROSPOT for IgM, IgA, IgG1, IgG3; and three/four color T-cell FLUOROSPOT for IL-2, IFN-γ, TNF-α, and GzB, in serial dilution experiments, we demonstrate the validity and accuracy of Fluoro-X™ multi-color spot counting algorithms. Statistical predictions based on the Poisson spatial distribution, coupled with scrambled image counting, permit objective correction of true multi-color spot counts to exclude randomly overlaid spots.
Group assessment of key indicators of sustainable waste management in developing countries.
Tot, Bojana; Vujić, Goran; Srđević, Zorica; Ubavin, Dejan; Russo, Mário Augusto Tavares
2017-09-01
Decision makers in developing countries are struggling to solve the present problems of solid waste management. Prioritisation and ranking of the most important indicators that influence the waste management system is very useful for any decision maker for the future planning and implementation of a sustainable waste management system. The aim of this study is to evaluate key indicators and their related sub-indicators in a group decision-making environment. In order to gain insight into the subject it was necessary to obtain the qualified opinions of decision makers from different countries who understand the situation in the sector of waste management in developing countries. An assessment is performed by 43 decision makers from both developed and developing countries, and the applied methodology is based on a combined use of the analytic hierarchy process, from the multi-criteria decision-making set of tools, and the preferential voting method known as Borda Count, which belongs to social choice theory. Pairwise comparison of indicators is performed with the analytic hierarchy process, and the ranking of indicators once obtained is assessed with Borda Count. Detailed analysis of the final results showed that the Institutional-Administrative indicator was the most important one, with the maximum weight as derived by both groups of decision makers. The results also showed that the combined use of the analytic hierarchy process and Borda Count contributes to the credibility and objectivity of the decision-making process, allowing its use in more complex waste management group decision-making problems to be recommended.
Counting OCR errors in typeset text
NASA Astrophysics Data System (ADS)
Sandberg, Jonathan S.
1995-03-01
Frequently object recognition accuracy is a key component in the performance analysis of pattern matching systems. In the past three years, the results of numerous excellent and rigorous studies of OCR system typeset-character accuracy (henceforth OCR accuracy) have been published, encouraging performance comparisons between a variety of OCR products and technologies. These published figures are important; OCR vendor advertisements in the popular trade magazines lead readers to believe that published OCR accuracy figures effect market share in the lucrative OCR market. Curiously, a detailed review of many of these OCR error occurrence counting results reveals that they are not reproducible as published and they are not strictly comparable due to larger variances in the counts than would be expected by the sampling variance. Naturally, since OCR accuracy is based on a ratio of the number of OCR errors over the size of the text searched for errors, imprecise OCR error accounting leads to similar imprecision in OCR accuracy. Some published papers use informal, non-automatic, or intuitively correct OCR error accounting. Still other published results present OCR error accounting methods based on string matching algorithms such as dynamic programming using Levenshtein (edit) distance but omit critical implementation details (such as the existence of suspect markers in the OCR generated output or the weights used in the dynamic programming minimization procedure). The problem with not specifically revealing the accounting method is that the number of errors found by different methods are significantly different. This paper identifies the basic accounting methods used to measure OCR errors in typeset text and offers an evaluation and comparison of the various accounting methods.
Cultural Diversity and Civic Education: Two Versions of the Fragmentation Objection
ERIC Educational Resources Information Center
Shorten, Andrew
2010-01-01
According to the "fragmentation objection" to multiculturalism, practices of cultural recognition undermine political stability, and this counts as a reason to be sceptical about the public recognition of minority cultures, as well as about multiculturalism construed more broadly as a public policy. Civic education programmes, designed to promote…
NASA Astrophysics Data System (ADS)
Leiva, Josue Nahun; Robbins, James; Saraswat, Dharmendra; She, Ying; Ehsani, Reza
2017-07-01
This study evaluated the effect of flight altitude and canopy separation of container-grown Fire Chief™ arborvitae (Thuja occidentalis L.) on counting accuracy. Images were taken at 6, 12, and 22 m above the ground using unmanned aircraft systems. Plants were spaced to achieve three canopy separation treatments: 5 cm between canopy edges, canopy edges touching, and 5 cm of canopy edge overlap. Plants were placed on two different ground covers: black fabric and gravel. A counting algorithm was trained using Feature Analyst®. Total counting error, false positives, and unidentified plants were reported for images analyzed. In general, total counting error was smaller when plants were fully separated. The effect of ground cover on counting accuracy varied with the counting algorithm. Total counting error for plants placed on gravel (-8) was larger than for those on a black fabric (-2), however, false positive counts were similar for black fabric (6) and gravel (6). Nevertheless, output images of plants placed on gravel did not show a negative effect due to the ground cover but was impacted by differences in image spatial resolution.
Dropout Count Procedural Handbook.
ERIC Educational Resources Information Center
Nevada State Dept. of Education, Carson City. Planning, Research and Evaluation Branch.
This manual outlines the procedure for counting dropouts from the Nevada schools. The State Department of Education instituted a new dropout counting procedure to its student accounting system in January 1988 as part of its response to recommendations of a task force on at-risk youth. The count is taken from each secondary school and includes…
Modeling visual clutter perception using proto-object segmentation
Yu, Chen-Ping; Samaras, Dimitris; Zelinsky, Gregory J.
2014-01-01
We introduce the proto-object model of visual clutter perception. This unsupervised model segments an image into superpixels, then merges neighboring superpixels that share a common color cluster to obtain proto-objects—defined here as spatially extended regions of coherent features. Clutter is estimated by simply counting the number of proto-objects. We tested this model using 90 images of realistic scenes that were ranked by observers from least to most cluttered. Comparing this behaviorally obtained ranking to a ranking based on the model clutter estimates, we found a significant correlation between the two (Spearman's ρ = 0.814, p < 0.001). We also found that the proto-object model was highly robust to changes in its parameters and was generalizable to unseen images. We compared the proto-object model to six other models of clutter perception and demonstrated that it outperformed each, in some cases dramatically. Importantly, we also showed that the proto-object model was a better predictor of clutter perception than an actual count of the number of objects in the scenes, suggesting that the set size of a scene may be better described by proto-objects than objects. We conclude that the success of the proto-object model is due in part to its use of an intermediate level of visual representation—one between features and objects—and that this is evidence for the potential importance of a proto-object representation in many common visual percepts and tasks. PMID:24904121
Counting of fermions and spins in strongly correlated systems in and out of thermal equilibrium
NASA Astrophysics Data System (ADS)
Braungardt, Sibylle; Rodríguez, Mirta; Sen(de), Aditi; Sen, Ujjwal; Glauber, Roy J.; Lewenstein, Maciej
2011-01-01
Atom counting theory can be used to study the role of thermal noise in quantum phase transitions and to monitor the dynamics of a quantum system. We illustrate this for a strongly correlated fermionic system, which is equivalent to an anisotropic quantum XY chain in a transverse field and can be realized with cold fermionic atoms in an optical lattice. We analyze the counting statistics across the phase diagram in the presence of thermal fluctuations and during its thermalization when the system is coupled to a heat bath. At zero temperature, the quantum phase transition is reflected in the cumulants of the counting distribution. We find that the signatures of the crossover remain visible at low temperature and are obscured with increasing thermal fluctuations. We find that the same quantities may be used to scan the dynamics during the thermalization of the system.
How many fish in a tank? Constructing an automated fish counting system by using PTV analysis
NASA Astrophysics Data System (ADS)
Abe, S.; Takagi, T.; Takehara, K.; Kimura, N.; Hiraishi, T.; Komeyama, K.; Torisawa, S.; Asaumi, S.
2017-02-01
Because escape from a net cage and mortality are constant problems in fish farming, health control and management of facilities are important in aquaculture. In particular, the development of an accurate fish counting system has been strongly desired for the Pacific Bluefin tuna farming industry owing to the high market value of these fish. The current fish counting method, which involves human counting, results in poor accuracy; moreover, the method is cumbersome because the aquaculture net cage is so large that fish can only be counted when they move to another net cage. Therefore, we have developed an automated fish counting system by applying particle tracking velocimetry (PTV) analysis to a shoal of swimming fish inside a net cage. In essence, we treated the swimming fish as tracer particles and estimated the number of fish by analyzing the corresponding motion vectors. The proposed fish counting system comprises two main components: image processing and motion analysis, where the image-processing component abstracts the foreground and the motion analysis component traces the individual's motion. In this study, we developed a Region Extraction and Centroid Computation (RECC) method and a Kalman filter and Chi-square (KC) test for the two main components. To evaluate the efficiency of our method, we constructed a closed system, placed an underwater video camera with a spherical curved lens at the bottom of the tank, and recorded a 360° view of a swimming school of Japanese rice fish (Oryzias latipes). Our study showed that almost all fish could be abstracted by the RECC method and the motion vectors could be calculated by the KC test. The recognition rate was approximately 90% when more than 180 individuals were observed within the frame of the video camera. These results suggest that the presented method has potential application as a fish counting system for industrial aquaculture.
Particle detection systems and methods
Morris, Christopher L.; Makela, Mark F.
2010-05-11
Techniques, apparatus and systems for detecting particles such as muons and neutrons. In one implementation, a particle detection system employs a plurality of drift cells, which can be for example sealed gas-filled drift tubes, arranged on sides of a volume to be scanned to track incoming and outgoing charged particles, such as cosmic ray-produced muons. The drift cells can include a neutron sensitive medium to enable concurrent counting of neutrons. The system can selectively detect devices or materials, such as iron, lead, gold, uranium, plutonium, and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can concurrently detect any unshielded neutron sources occupying the volume from neutrons emitted therefrom. If necessary, the drift cells can be used to also detect gamma rays. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.
Simulation on Poisson and negative binomial models of count road accident modeling
NASA Astrophysics Data System (ADS)
Sapuan, M. S.; Razali, A. M.; Zamzuri, Z. H.; Ibrahim, K.
2016-11-01
Accident count data have often been shown to have overdispersion. On the other hand, the data might contain zero count (excess zeros). The simulation study was conducted to create a scenarios which an accident happen in T-junction with the assumption the dependent variables of generated data follows certain distribution namely Poisson and negative binomial distribution with different sample size of n=30 to n=500. The study objective was accomplished by fitting Poisson regression, negative binomial regression and Hurdle negative binomial model to the simulated data. The model validation was compared and the simulation result shows for each different sample size, not all model fit the data nicely even though the data generated from its own distribution especially when the sample size is larger. Furthermore, the larger sample size indicates that more zeros accident count in the dataset.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bharoto,; Suparno, Nadi; Putra, Edy Giri Rachman
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card)more » for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.« less
NASA Astrophysics Data System (ADS)
Bharoto, Suparno, Nadi; Putra, Edy Giri Rachman
2015-04-01
In 2005, the main computer for data acquisition and control system of Small-angle Neutron Scattering (SANS) BATAN Spectrometer (SMARTer) was replaced since it halted to operate the spectrometer. According to this replacement, the new software for data acquisition and control system has been developed in-house. Visual Basic programming language is used in developing the software. In the last two years, many developments have been made both in the hardware and also the software to conduct the experiment is more effective and efficient. Lately, the previous motor controller card (ISA Card) was replaced with the programmable motor controller card (PCI Card) for driving one motor of position sensitive detector (PSD), eight motors of four collimators, and six motors of six pinhole discs. This new control system software makes all motors can be moved simultaneously, then it reduces significantly the consuming time of setting up the instrument before running the experiment. Along with that development, the new data acquisition software under MS Windows operating system is also developed to drive a beam stopper in X-Y directions as well as to read the equipment status such as position of the collimators and PSD, to acquire neutron counts on monitor and PSD detectors, and also to manage 12 samples position automatically. A timer object which is set in one second to read the equipment status via serial port of the computer (RS232C), and general purpose interface board (GPIB) for reading the total counts of each pixel of the PSD from histogram memory was used in this new software. The experiment result displayed in real time on the main window, and the data is saved in the special format for further data reduction and analysis. The new software has been implemented and performed for experiment using a preset count or preset time mode for absolute scattering intensity method.
Validation of an automated colony counting system for group A Streptococcus.
Frost, H R; Tsoi, S K; Baker, C A; Laho, D; Sanderson-Smith, M L; Steer, A C; Smeesters, P R
2016-02-08
The practice of counting bacterial colony forming units on agar plates has long been used as a method to estimate the concentration of live bacteria in culture. However, due to the laborious and potentially error prone nature of this measurement technique, an alternative method is desirable. Recent technologic advancements have facilitated the development of automated colony counting systems, which reduce errors introduced during the manual counting process and recording of information. An additional benefit is the significant reduction in time taken to analyse colony counting data. Whilst automated counting procedures have been validated for a number of microorganisms, the process has not been successful for all bacteria due to the requirement for a relatively high contrast between bacterial colonies and growth medium. The purpose of this study was to validate an automated counting system for use with group A Streptococcus (GAS). Twenty-one different GAS strains, representative of major emm-types, were selected for assessment. In order to introduce the required contrast for automated counting, 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) dye was added to Todd-Hewitt broth with yeast extract (THY) agar. Growth on THY agar with TTC was compared with growth on blood agar and THY agar to ensure the dye was not detrimental to bacterial growth. Automated colony counts using a ProtoCOL 3 instrument were compared with manual counting to confirm accuracy over the stages of the growth cycle (latent, mid-log and stationary phases) and in a number of different assays. The average percentage differences between plating and counting methods were analysed using the Bland-Altman method. A percentage difference of ±10 % was determined as the cut-off for a critical difference between plating and counting methods. All strains measured had an average difference of less than 10 % when plated on THY agar with TTC. This consistency was also observed over all phases of the growth cycle and when plated in blood following bactericidal assays. Agreement between these methods suggest the use of an automated colony counting technique for GAS will significantly reduce time spent counting bacteria to enable a more efficient and accurate measurement of bacteria concentration in culture.
Hallas, Gary; Monis, Paul
2015-01-01
The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers.
Skull counting in late stages after internal contamination by actinides.
Tani, Kotaro; Shutt, Arron; Kurihara, Osamu; Kosako, Toshiso
2015-02-01
Monitoring preparation for internal contamination with actinides (e.g. Pu and Am) is required to assess internal doses at nuclear fuel cycle-related facilities. In this paper, the authors focus on skull counting in case of single-incident inhalation of (241)Am and propose an effective procedure for skull counting with an existing system, taking into account the biokinetic behaviour of (241)Am in the human body. The predicted response of the system to skull counting under a certain counting geometry was found to be only ∼1.0 × 10(-5) cps Bq(-1) 1y after intake. However, this disadvantage could be remedied by repeated measurements of the skull during the late stage of the intake due to the predicted response reaching a plateau at about the 1000th day after exposure and exceeding that in the lung counting. Further studies are needed for the development of a new detection system with higher sensitivity to perform reliable internal dose estimations based on direct measurements. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Clustering method for counting passengers getting in a bus with single camera
NASA Astrophysics Data System (ADS)
Yang, Tao; Zhang, Yanning; Shao, Dapei; Li, Ying
2010-03-01
Automatic counting of passengers is very important for both business and security applications. We present a single-camera-based vision system that is able to count passengers in a highly crowded situation at the entrance of a traffic bus. The unique characteristics of the proposed system include, First, a novel feature-point-tracking- and online clustering-based passenger counting framework, which performs much better than those of background-modeling-and foreground-blob-tracking-based methods. Second, a simple and highly accurate clustering algorithm is developed that projects the high-dimensional feature point trajectories into a 2-D feature space by their appearance and disappearance times and counts the number of people through online clustering. Finally, all test video sequences in the experiment are captured from a real traffic bus in Shanghai, China. The results show that the system can process two 320×240 video sequences at a frame rate of 25 fps simultaneously, and can count passengers reliably in various difficult scenarios with complex interaction and occlusion among people. The method achieves high accuracy rates up to 96.5%.
Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C
2009-04-01
Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor (r2 values ranged from < 0.01 to 0.47), and the ATP method was not sufficiently sensitive to measure counts below approximately 10(4) CFU/mL.
2008-01-01
Objective To determine if citation counts at two years could be predicted for clinical articles that pass basic criteria for critical appraisal using data within three weeks of publication from external sources and an online article rating service. Design Retrospective cohort study. Setting Online rating service, Canada. Participants 1274 articles from 105 journals published from January to June 2005, randomly divided into a 60:40 split to provide derivation and validation datasets. Main outcome measures 20 article and journal features, including ratings of clinical relevance and newsworthiness, routinely collected by the McMaster online rating of evidence system, compared with citation counts at two years. Results The derivation analysis showed that the regression equation accounted for 60% of the variation (R2=0.60, 95% confidence interval 0.538 to 0.629). This model applied to the validation dataset gave a similar prediction (R2=0.56, 0.476 to 0.596, shrinkage 0.04; shrinkage measures how well the derived equation matches data from the validation dataset). Cited articles in the top half and top third were predicted with 83% and 61% sensitivity and 72% and 82% specificity. Higher citations were predicted by indexing in numerous databases; number of authors; abstraction in synoptic journals; clinical relevance scores; number of cited references; and original, multicentred, and therapy articles from journals with a greater proportion of articles abstracted. Conclusion Citation counts can be reliably predicted at two years using data within three weeks of publication. PMID:18292132
Use of Dehydrated Agar to Estimate Microbial Water Quality for Horticulture Irrigation.
Meador, Dustin P; Fisher, Paul R; Guy, Charles L; Harmon, Philip F; Peres, Natalia A; Teplitski, Max
2016-07-01
Petrifilms are dehydrated agar culture plates that have been used to quantify colony forming units (CFU) mL of either aerobic bacteria (Petrifilm-AC) or fungus (Petrifilm-YM), depending on substrate composition. Microbes in irrigation systems can indicate biofilm risk and potential clogging of irrigation emitters. The research objective was to compare counts on Petrifilms versus traditional, hydrated-agar plates using samples collected from recirculated irrigation waters and cultures of isolated known species. The estimated count (in CFU mL) from a recirculated irrigation sample after 7 d of incubation on Petrifilm-YM was only 5.5% of the count quantified using sabouraud dextrose agar (SDA) with chloramphenicol after 14 d. In a separate experiment with a known species, Petrifilm-YM did not successfully culture zoospores of . Isolates of viable zoospores were cultured successfully on potato-dextrose agar (PDA), with comparable counts with a vegetable juice medium supplemented with the antibiotics pimaricin, ampicillin, rifamycin, pentochloronitrobenzene and hymexazol (PARP-H). The quantification of pv. Begoniaceae on Petrifilm-AC was not significantly different ( < 0.05) than on PDA, but was lower than on Reasoner and Goldrich agar (R2A) or with a hemocytometer. The current formulation of Petrifilm-YM is unlikely to be a useful monitoring method for plant pathogens in irrigation water because of the inability to successfully culture oomycetes. However, Petrifilm-AC was an effective method to quantify bacteria and can provide an easy-to-use on-farm tool to monitor biofilm risk and microbial density. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Maruyama, N; Mori, A; Shono, S; Oda, H; Sako, T
2018-03-01
Porphyromonas gulae, Tannerella forsythia and Campylobacter rectus are considered dominant periodontal pathogens in dogs. Recently, quantitative real-time PCR (qRT-PCR) methods have been used for absolute quantitative determination of oral bacterial counts. The purpose of the present study was to establish a standardized qRT-PCR procedure to quantify bacterial counts of the three target periodontal bacteria (P. gulae, T. forsythia and C. rectus). Copy numbers of the three target periodontal bacteria were evaluated in 26 healthy dogs. Then, changes in bacterial counts of the three target periodontal bacteria were evaluated for 24 weeks in 7 healthy dogs after periodontal scaling. Analytical evaluation of each self-designed primer indicated acceptable analytical imprecision. All 26 healthy dogs were found to be positive for P. gulae, T. forsythia and C. rectus. Median total bacterial counts (copies/ng) of each target genes were 385.612 for P. gulae, 25.109 for T. forsythia and 5.771 for C. rectus. Significant differences were observed between the copy numbers of the three target periodontal bacteria. Periodontal scaling reduced median copy numbers of the three target periodontal bacteria in 7 healthy dogs. However, after periodontal scaling, copy numbers of all three periodontal bacteria significantly increased over time (p<0.05, Kruskal-Wallis test) (24 weeks). In conclusion, our results demonstrated that qRT-PCR can accurately measure periodontal bacteria in dogs. Furthermore, the present study has revealed that qRT-PCR method can be considered as a new objective evaluation system for canine periodontal disease. Copyright© by the Polish Academy of Sciences.
The topology of galaxy clustering.
NASA Astrophysics Data System (ADS)
Coles, P.; Plionis, M.
The authors discuss an objective method for quantifying the topology of the galaxy distribution using only projected galaxy counts. The method is a useful complement to fully three-dimensional studies of topology based on the genus by virtue of the enormous projected data sets available. Applying the method to the Lick counts they find no evidence for large-scale non-gaussian behaviour, whereas the small-scale distribution is strongly non-gaussian, with a shift in the meatball direction.
Determination of Optimum Operating Parameters of Single-Electron Photomultiplier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lukichev, A.A.; Shalyapin, A.L.; Shul'gin, B.V.
1986-06-01
This paper presents a procedure for determining the effective quantum yield and average gain of the dynode system of a photomultiplier. An objective performance figure, the extrapolated count response, is introduced. The results for FEU-142 photomultiplier studies are given. The radiation source used in the studies was a PRK-2 mercury-vapor lamp with a regulated power supply. The recorder was a pulse analyzer based on a UNO-4096-90, which was equipped with BPA-2-95, BPV-2-90, and UVTs-2-90 units. The amplifier used a KP303V transistor and a 140UD1B operational amplifier.
NASA Astrophysics Data System (ADS)
Boutet, J.; Debourdeau, M.; Laidevant, A.; Hervé, L.; Dinten, J.-M.
2010-02-01
Finding a way to combine ultrasound and fluorescence optical imaging on an endorectal probe may improve early detection of prostate cancer. A trans-rectal probe adapted to fluorescence diffuse optical tomography measurements was developed by our team. This probe is based on a pulsed NIR laser source, an optical fiber network and a time-resolved detection system. A reconstruction algorithm was used to help locate and quantify fluorescent prostate tumors. In this study, two different kinds of time-resolved detectors are compared: High Rate Imaging system (HRI) and a photon counting system. The HRI is based on an intensified multichannel plate and a CCD Camera. The temporal resolution is obtained through a gating of the HRI. Despite a low temporal resolution (300ps), this system allows a simultaneous acquisition of the signal from a large number of detection fibers. In the photon counting setup, 4 photomultipliers are connected to a Time Correlated Single Photon Counting (TCSPC) board, providing a better temporal resolution (0.1 ps) at the expense of a limited number of detection fibers (4). At last, we show that the limited number of detection fibers of the photon counting setup is enough for a good localization and dramatically improves the overall acquisition time. The photon counting approach is then validated through the localization of fluorescent inclusions in a prostate-mimicking phantom.
Eghrari, Allen O; Mumtaz, Aisha A; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S; Riazuddin, S Amer; Gottsch, John D
2017-01-01
Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870-0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797-0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.
Eghrari, Allen O.; Mumtaz, Aisha A.; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S.; Riazuddin, S. Amer; Gottsch, John D.
2016-01-01
Purpose Retroillumination photography analysis (RPA) is an objective tool for assessment of the number and distribution of guttae in eyes affected with Fuchs Corneal Dystrophy (FCD). Current protocols include manual processing of images; here we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Methods Retroillumination photographs of 97 FCD-affected corneas were acquired and total counts of guttae previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. Results A set of 97 retroillumination photographs were analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R2=0.79) and manual counts (R2=0.88). Intraclass correlation coefficient demonstrated strong correlation, at 0.924 (95% CI, 0.870- 0.958) among cases analyzed by three students, and 0.869 (95% CI, 0.797- 0.918) among cases for which images was analyzed by an ophthalmologist and two students. Conclusions Automated RPA allows for grading of FCD severity with high resolution across a spectrum of disease severity. PMID:27811565
State traffic volume systems council estimation process.
DOT National Transportation Integrated Search
2004-10-01
The Kentucky Transportation Cabinet has an immense traffic data collection program that is an essential source for many other programs. The Division of Planning processes traffic volume counts annually. These counts are maintained in the Counts Datab...
A Vacuum-Aspirator for Counting Termites
Susan C. Jones; Joe K. Mauldin
1983-01-01
An aspirator-system powered by a vacuum cleaner is described for manually counting termites. It is significantly faster and termite survival is at least as high as when using a mouth-aspirator for counting large numbers of termites.
White Blood Cells, Neutrophils, and Reactive Oxygen Metabolites among Asymptomatic Subjects.
Kotani, Kazuhiko; Sakane, Naoki
2012-06-01
Chronic inflammation and oxidative stress are associated with health and the disease status. The objective of the present study was to investigate the association among white blood cell (WBC) counts, neutrophil counts as a WBC subpopulation, and diacron reactive oxygen metabolites (d-ROMs) levels in an asymptomatic population. The clinical data, including general cardiovascular risk variables and high-sensitivity C-reactive protein (hs-CRP), were collected from 100 female subjects (mean age, 62 years) in outpatient clinics. The correlation of the d-ROMs with hs-CRP, WBC, and neutrophil counts was examined. The mean/median levels were WBC counts 5.9 × 10(9)/L, neutrophil counts 3.6 × 10(9)/L, hs-CRP 0.06 mg/dL, and d-ROMs 359 CURR U. A simple correlation analysis showed a significant positive correlation of the d-ROMs with the WBC counts, neutrophil counts, or hs-CRP levels. The correlation between d-ROMs and neutrophil counts (β = 0.22, P < 0.05), as well as that between d-ROMs and hs-CRP (β = 0.28, P < 0.01), remained significant and independent in a multiple linear regression analysis adjusted for other variables. A multiple linear regression analysis showed that WBC counts had only a positive correlation tendency to the d-ROMs. Neutrophils may be slightly but more involved in the oxidative stress status, as assessed by d-ROMs, in comparison to the overall WBC. Further studies are needed to clarify the biologic mechanism(s) of the observed relationship.
The effect of a secondary cognitive task on landing mechanics and jump performance.
Dai, Boyi; Cook, Ross F; Meyer, Elizabeth A; Sciascia, Yvonne; Hinshaw, Taylour J; Wang, Chaoyi; Zhu, Qin
2018-06-01
Anterior cruciate ligament (ACL) injuries commonly occur during jump-landing tasks when individuals' attention is simultaneously allocated to other objects and tasks. The purpose of the current study was to investigate the effect of allocation of attention imposed by a secondary cognitive task on landing mechanics and jump performance. Thirty-eight recreational athletes performed a jump-landing task in three conditions: no counting, counting backward by 1 s from a randomly given number, and counting backward by 7 s from a randomly given number. Three-dimensional kinematics and ground reaction forces were collected and analysed. Participants demonstrated decreased knee flexion angles at initial contact (p = 0.001) for the counting by 1 s condition compared with the no counting condition. Participants also showed increased peak posterior and vertical ground reaction forces during the first 100 ms of landing (p ≤ 0.023) and decreased jump height (p < 0.001) for the counting by 1 s and counting by 7 s conditions compared with the no counting condition. Imposition of a simultaneous cognitive challenge resulted in landing mechanics associated with increased ACL loading and decreased jump performance. ACL injury risk screening protocols and injury prevention programmes may incorporate cognitive tasks into jump-landing tasks to better simulate sports environments.
The factors affecting on estimation of carbohydrate content of meals in carbohydrate counting
Kawamura, Tomoyuki; Takamura, Chihiro; Hirose, Masakazu; Hashimoto, Tomomi; Higashide, Takashi; Kashihara, Yoneo; Hashimura, Kayako; Shintaku, Haruo
2015-01-01
Abstract. The objective of this study was to identify factors affecting on errors in carbohydrate (CHO) content estimation during CHO counting. Thirty-seven type 1 diabetes patients and 22 of their parents and 28 physicians/dieticians were enrolled in this study. CHO counting was counted in “Carb”, with 1 Carb defined as 10 g of CHO. To evaluate the accuracy of CHO counting, 80 real-size photographs of cooked meals were presented to the subjects for Carb estimation. Carbs tended to be overestimated for foods containing relatively small amounts of Carbs. On the other hands, Carbs tended to be underestimated for foods with higher than 6 Carbs. Accurate estimation of the Carbs in food containing a large amount of rice was particularly difficult even in the subjects having the CHO counting experience. The Carb contents of high-calorie foods such as meats, fried foods, and desserts tended to be overestimated. This error was smaller in subjects having the CHO counting experience. In conclusion, misunderstanding of high-calorie dishes containing high amounts of CHO was observed in inexperienced subjects, indicating the efficacy of the current methodology of CHO counting. On the other hand it was difficult even for experienced subjects to assess the amount of seasoned rice, suggesting the need for a new methodology for accurate estimation. PMID:26568656
Hsu, Wan-Ling; Tatsukawa, Yoshimi; Neriishi, Kazuo; Yamada, Michiko; Cologne, John; Fujiwara, Saeko
2010-01-01
In studying the late health effects of atomic-bomb (A-bomb) survivors, earlier findings were that white blood cell (WBC) count increased with radiation dose in cross-sectional studies. However, a persistent effect of radiation on WBC count and other risk factors has yet to be confirmed. The objectives of the present study were 1) to examine the longitudinal relationship between A-bomb radiation dose and WBC and differential WBC counts among A-bomb survivors and 2) to investigate the potential confounding risk factors (such as age at exposure and smoking status) as well as modification of the radiation dose-response. A total of 7,562 A-bomb survivors in Hiroshima and Nagasaki were included in this study from 1964-2004. A linear mixed model was applied using the repeated WBC measurements. During the study period, a secular downward trend of WBC count was observed. Radiation exposure was a significant risk factor for elevated WBC and differential WBC counts over time. A significant increase of WBC counts among survivors with high radiation dose (> 2 Gy) was detected in men exposed below the age of 20 and in women regardless of age at exposure. Effects on WBC of low dose radiation remain unclear, however. Cigarette smoking produced the most pronounced effect on WBC counts and its impact was much larger than that of radiation exposure.
Reduction of energy intake using just-in-time feedback from a wearable sensor system.
Farooq, Muhammad; McCrory, Megan A; Sazonov, Edward
2017-04-01
This work explored the potential use of a wearable sensor system for providing just-in-time (JIT) feedback on the progression of a meal and tested its ability to reduce the total food mass intake. Eighteen participants consumed three meals each in a lab while monitored by a wearable sensor system capable of accurately tracking chew counts. The baseline visit was used to establish the self-determined ingested mass and the associated chew counts. Real-time feedback on chew counts was provided in the next two visits, during which the target chew count was either the same as that at baseline or the baseline chew count reduced by 25% (in randomized order). The target was concealed from the participant and from the experimenter. Nonparametric repeated-measures ANOVAs were performed to compare mass of intake, meal duration, and ratings of hunger, appetite, and thirst across three meals. JIT feedback targeting a 25% reduction in chew counts resulted in a reduction in mass and energy intake without affecting perceived hunger or fullness. JIT feedback on chewing behavior may reduce intake within a meal. This system can be further used to help develop individualized strategies to provide JIT adaptive interventions for reducing energy intake. © 2017 The Obesity Society.
The AOLI Non-Linear Curvature Wavefront Sensor: High sensitivity reconstruction for low-order AO
NASA Astrophysics Data System (ADS)
Crass, Jonathan; King, David; Mackay, Craig
2013-12-01
Many adaptive optics (AO) systems in use today require bright reference objects to determine the effects of atmospheric distortions on incoming wavefronts. This requirement is because Shack Hartmann wavefront sensors (SHWFS) distribute incoming light from reference objects into a large number of sub-apertures. Bright natural reference objects occur infrequently across the sky leading to the use of laser guide stars which add complexity to wavefront measurement systems. The non-linear curvature wavefront sensor as described by Guyon et al. has been shown to offer a significant increase in sensitivity when compared to a SHWFS. This facilitates much greater sky coverage using natural guide stars alone. This paper describes the current status of the non-linear curvature wavefront sensor being developed as part of an adaptive optics system for the Adaptive Optics Lucky Imager (AOLI) project. The sensor comprises two photon-counting EMCCD detectors from E2V Technologies, recording intensity at four near-pupil planes. These images are used with a reconstruction algorithm to determine the phase correction to be applied by an ALPAO 241-element deformable mirror. The overall system is intended to provide low-order correction for a Lucky Imaging based multi CCD imaging camera. We present the current optical design of the instrument including methods to minimise inherent optical effects, principally chromaticity. Wavefront reconstruction methods are discussed and strategies for their optimisation to run at the required real-time speeds are introduced. Finally, we discuss laboratory work with a demonstrator setup of the system.
Can the big five factors of personality predict lymphocyte counts?
Ožura, Ana; Ihan, Alojz; Musek, Janek
2012-03-01
Psychological stress is known to affect the immune system. The Limbic Hypothalamic Pituitary Adrenal (LHPA) axis has been identified as the principal path of the bidirectional communication between the immune system and the central nervous system with significant psychological activators. Personality traits acted as moderators of the relationship between life conflicts and psychological distress. This study focuses on the relationship between the Big Five factors of personality and immune regulation as indicated by Lymphocyte counts. Our study included 32 professional soldiers from the Slovenian Army that completed the Big Five questionnaire (Goldberg IPIP-300). We also assessed their white blood cell counts with a detailed lymphocyte analysis using flow cytometry. The correlations between personality variables and immune system parameters were calculated. Furthermore, regression analyses were performed using personality variables as predictors and immune parameters as criteria. The results demonstrated that the model using the Big Five factors as predictors of Lymphocyte counts is significant in predicting the variance in NK and B cell counts. Agreeableness showed the strongest predictive function. The results offer support for the theoretical models that stressed the essential links between personality and immune regulation. Further studies with larger samples examining the Big five factors and immune system parameters are needed.
Neutronic analysis of the 1D and 1E banks reflux detection system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blanchard, A.
1999-12-21
Two H Canyon neutron monitoring systems for early detection of postulated abnormal reflux conditions in the Second Uranium Cycle 1E and 1D Mixer-Settle Banks have been designed and built. Monte Carlo neutron transport simulations using the general purpose, general geometry, n-particle MCNP code have been performed to model expected response of the monitoring systems to varying conditions.The confirmatory studies documented herein conclude that the 1E and 1D neutron monitoring systems are able to achieve adequate neutron count rates for various neutron source and detector configurations, thereby eliminating excessive integration count time. Neutron count rate sensitivity studies are also performed. Conversely,more » the transport studies concluded that the neutron count rates are statistically insensitive to nitric acid content in the aqueous region and to the transition region length. These studies conclude that the 1E and 1D neutron monitoring systems are able to predict the postulated reflux conditions for all examined perturbations in the neutron source and detector configurations. In the cases examined, the relative change in the neutron count rates due to postulated transitions from normal {sup 235}U concentration levels to reflux levels remain satisfactory detectable.« less
Usefulness of hemocytometer as a counting chamber in a computer assisted sperm analyzer (CASA)
Eljarah, A.; Chandler, J.; Jenkins, J.A.; Chenevert, J.; Alcanal, A.
2013-01-01
Several methods are used to determine sperm cell concentration, such as the haemocytometer, spectrophotometer, electronic cell counter and computer-assisted semen analysers (CASA). The utility of CASA systems has been limited due to the lack of characterization of individual systems and the absence of standardization among laboratories. The aims of this study were to: 1) validate and establish setup conditions for the CASA system utilizing the haemocytometer as a counting chamber, and 2) compare the different methods used for the determination of sperm cell concentration in bull semen. Two ejaculates were collected and the sperm cell concentration was determined using spectrophotometer and haemocytometer. For the Hamilton-Thorn method, the haemocytometer was used as a counting chamber. Sperm concentration was determined three times per ejaculate samples. A difference (P 0.05) or between the haemocytometer count and the spectrophotometer. Based on the results of this study, we concluded that the haemocytometer can be used in computerized semen analysis systems as a substitute for the commercially available disposable counting chambers, therefore avoiding disadvantageous high costs and slower procedures.
Imaging with a small number of photons
Morris, Peter A.; Aspden, Reuben S.; Bell, Jessica E. C.; Boyd, Robert W.; Padgett, Miles J.
2015-01-01
Low-light-level imaging techniques have application in many diverse fields, ranging from biological sciences to security. A high-quality digital camera based on a multi-megapixel array will typically record an image by collecting of order 105 photons per pixel, but by how much could this photon flux be reduced? In this work we demonstrate a single-photon imaging system based on a time-gated intensified camera from which the image of an object can be inferred from very few detected photons. We show that a ghost-imaging configuration, where the image is obtained from photons that have never interacted with the object, is a useful approach for obtaining images with high signal-to-noise ratios. The use of heralded single photons ensures that the background counts can be virtually eliminated from the recorded images. By applying principles of image compression and associated image reconstruction, we obtain high-quality images of objects from raw data formed from an average of fewer than one detected photon per image pixel. PMID:25557090
Application of image processing to calculate the number of fish seeds using raspberry-pi
NASA Astrophysics Data System (ADS)
Rahmadiansah, A.; Kusumawardhani, A.; Duanto, F. N.; Qoonita, F.
2018-03-01
Many fish cultivator in Indonesia who suffered losses due to the sale and purchase of fish seeds did not match the agreed amount. The loss is due to the calculation of fish seed still using manual method. To overcome these problems, then in this study designed fish counting system automatically and real-time fish using the image processing based on Raspberry Pi. Used image processing because it can calculate moving objects and eliminate noise. Image processing method used to calculate moving object is virtual loop detector or virtual detector method and the approach used is “double difference image”. The “double difference” approach uses information from the previous frame and the next frame to estimate the shape and position of the object. Using these methods and approaches, the results obtained were quite good with an average error of 1.0% for 300 individuals in a test with a virtual detector width of 96 pixels and a slope of 1 degree test plane.
Rapid enumeration of low numbers of moulds in tea based drinks using an automated system.
Tanaka, Kouichi; Yamaguchi, Nobuyasu; Baba, Takashi; Amano, Norihide; Nasu, Masao
2011-01-31
Aseptically prepared cold drinks based on tea have become popular worldwide. Contamination of these drinks with harmful microbes is a potential health problem because such drinks are kept free from preservatives to maximize aroma and flavour. Heat-tolerant conidia and ascospores of fungi can survive pasteurization, and need to be detected as quickly as possible. We were able to rapidly and accurately detect low numbers of conidia and ascospores in tea-based drinks using fluorescent staining followed by an automated counting system. Conidia or ascospores were inoculated into green tea and oolong tea, and samples were immediately filtered through nitrocellulose membranes (pore size: 0.8 μm) to concentrate fungal propagules. These were transferred onto potato dextrose agar and incubated for 23 h at 28 °C. Fungi germinating on the membranes were fluorescently stained for 30 min. The stained mycelia were counted selectively within 90s using an automated counting system (MGS-10LD; Chuo Electric Works, Osaka, Japan). Very low numbers (1 CFU/100ml) of conidia or ascospores could be rapidly counted, in contrast to traditional labour intensive techniques. All tested mould strains were detected within 24h while conventional plate counting required 72 h for colony enumeration. Counts of slow-growing fungi (Cladosporium cladosporioides) obtained by automated counting and by conventional plate counting were close (r(2) = 0.986). Our combination of methods enables counting of both fast- and slow-growing fungi, and should be useful for microbiological quality control of tea-based and also other drinks. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peronio, P.; Acconcia, G.; Rech, I.
Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring “long” data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach basedmore » on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (∼80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.« less
Preverbal and verbal counting and computation.
Gallistel, C R; Gelman, R
1992-08-01
We describe the preverbal system of counting and arithmetic reasoning revealed by experiments on numerical representations in animals. In this system, numerosities are represented by magnitudes, which are rapidly but inaccurately generated by the Meck and Church (1983) preverbal counting mechanism. We suggest the following. (1) The preverbal counting mechanism is the source of the implicit principles that guide the acquisition of verbal counting. (2) The preverbal system of arithmetic computation provides the framework for the assimilation of the verbal system. (3) Learning to count involves, in part, learning a mapping from the preverbal numerical magnitudes to the verbal and written number symbols and the inverse mappings from these symbols to the preverbal magnitudes. (4) Subitizing is the use of the preverbal counting process and the mapping from the resulting magnitudes to number words in order to generate rapidly the number words for small numerosities. (5) The retrieval of the number facts, which plays a central role in verbal computation, is mediated via the inverse mappings from verbal and written numbers to the preverbal magnitudes and the use of these magnitudes to find the appropriate cells in tabular arrangements of the answers. (6) This model of the fact retrieval process accounts for the salient features of the reaction time differences and error patterns revealed by experiments on mental arithmetic. (7) The application of verbal and written computational algorithms goes on in parallel with, and is to some extent guided by, preverbal computations, both in the child and in the adult.
Engaging Critically with "Objective" Critical Analysis: A Situated Response to Openshaw and Rata
ERIC Educational Resources Information Center
Andreotti, Vanessa
2009-01-01
Roger Openshaw and Elizabeth Rata conceptualise Kaupapa Maori as a dominant intellectual orthodoxy in New Zealand, which creates a "culturalist ideological conformity" that limits the university's ability to serve as the critical conscience of society. They argue for the primacy of academic objectivity as the criteria for what counts as…
Recursive Objects--An Object Oriented Presentation of Recursion
ERIC Educational Resources Information Center
Sher, David B.
2004-01-01
Generally, when recursion is introduced to students the concept is illustrated with a toy (Towers of Hanoi) and some abstract mathematical functions (factorial, power, Fibonacci). These illustrate recursion in the same sense that counting to 10 can be used to illustrate a for loop. These are all good illustrations, but do not represent serious…
Evidence for Two Attentional Components in Visual Working Memory
ERIC Educational Resources Information Center
Allen, Richard J.; Baddeley, Alan D.; Hitch, Graham J.
2014-01-01
How does executive attentional control contribute to memory for sequences of visual objects, and what does this reveal about storage and processing in working memory? Three experiments examined the impact of a concurrent executive load (backward counting) on memory for sequences of individually presented visual objects. Experiments 1 and 2 found…
Establishment of HPC(R2A) for regrowth control in non-chlorinated distribution systems.
Uhl, Wolfgang; Schaule, Gabriela
2004-05-01
Drinking water distributed without disinfection and without regrowth problems for many years may show bacterial regrowth when the residence time and/or temperature in the distribution system increases or when substrate and/or bacterial concentration in the treated water increases. An example of a regrowth event in a major German city is discussed. Regrowth of HPC bacteria occurred unexpectedly at the end of a very hot summer. No pathogenic or potentially pathogenic bacteria were identified. Increased residence times in the distribution system and temperatures up to 25 degrees C were identified as most probable causes and the regrowth event was successfully overcome by changing flow regimes and decreasing residence times. Standard plate counts of HPC bacteria using the spread plate technique on nutrient rich agar according to German Drinking Water Regulations (GDWR) had proven to be a very good indicator of hygienically safe drinking water and to demonstrate the effectiveness of water treatment. However, the method proved insensitive for early regrowth detection. Regrowth experiments in the lab and sampling of the distribution system during two summers showed that spread plate counts on nutrient-poor R2A agar after 7-day incubation yielded 100 to 200 times higher counts. Counts on R2A after 3-day incubation were three times less than after 7 days. As the precision of plate count methods is very poor for counts less than 10 cfu/plate, a method yielding higher counts is better suited to detect upcoming regrowth than a method yielding low counts. It is shown that for the identification of regrowth events HPC(R2A) gives a further margin of about 2 weeks for reaction before HPC(GDWR). Copyright 2003 Elsevier B.V.
ERIC Educational Resources Information Center
Hall, D. Geoffrey; Williams, Sean G.; Belanger, Julie
2010-01-01
In two experiments, one hundred ninety-two 3-year-olds, 4-year-olds, and adults heard a novel word for a target object and then were asked to extend the label to one of two test objects, one matching in shape-based object category (the shape match) and the other matching in a property other than shape (the property match). We independently…
Long terms trends in CD4+ cell counts, CD8+ cell counts, and the CD4+ : CD8+ ratio
Hughes, Rachael A.; May, Margaret T.; Tilling, Kate; Taylor, Ninon; Wittkop, Linda; Reiss, Peter; Gill, John; Schommers, Philipp; Costagliola, Dominique; Guest, Jodie L.; Lima, Viviane D.; d’Arminio Monforte, Antonella; Smith, Colette; Cavassini, Matthias; Saag, Michael; Castilho, Jessica L.; Sterne, Jonathan A.C.
2018-01-01
Objective: Model trajectories of CD4+ and CD8+ cell counts after starting combination antiretroviral therapy (ART) and use the model to predict trends in these counts and the CD4+ : CD8+ ratio. Design: Cohort study of antiretroviral-naïve HIV-positive adults who started ART after 1997 (ART Cohort Collaboration) with more than 6 months of follow-up data. Methods: We jointly estimated CD4+ and CD8+ cell count trends and their correlation using a bivariate random effects model, with linear splines describing their population trends, and predicted the CD4+ : CD8+ ratio trend from this model. We assessed whether CD4+ and CD8+ cell count trends and the CD4+ : CD8+ ratio trend varied according to CD4+ cell count at start of ART (baseline), and, whether these trends differed in patients with and without virological failure more than 6 months after starting ART. Results: A total of 39 979 patients were included (median follow-up was 53 months). Among patients with baseline CD4+ cell count at least 50 cells/μl, predicted mean CD8+ cell counts continued to decrease between 3 and 15 years post-ART, partly driving increases in the predicted mean CD4+ : CD8+ ratio. During 15 years of follow-up, normalization of the predicted mean CD4+ : CD8+ ratio (to >1) was only observed among patients with baseline CD4+ cell count at least 200 cells/μl. A higher baseline CD4+ cell count predicted a shorter time to normalization. Conclusion: Declines in CD8+ cell count and increases in CD4+ : CD8+ ratio occurred up to 15 years after starting ART. The likelihood of normalization of the CD4+ : CD8+ ratio is strongly related to baseline CD4+ cell count. PMID:29851663
Lourenco, Stella F.; Bonny, Justin W.; Fernandez, Edmund P.; Rao, Sonia
2012-01-01
Humans and nonhuman animals share the capacity to estimate, without counting, the number of objects in a set by relying on an approximate number system (ANS). Only humans, however, learn the concepts and operations of symbolic mathematics. Despite vast differences between these two systems of quantification, neural and behavioral findings suggest functional connections. Another line of research suggests that the ANS is part of a larger, more general system of magnitude representation. Reports of cognitive interactions and common neural coding for number and other magnitudes such as spatial extent led us to ask whether, and how, nonnumerical magnitude interfaces with mathematical competence. On two magnitude comparison tasks, college students estimated (without counting or explicit calculation) which of two arrays was greater in number or cumulative area. They also completed a battery of standardized math tests. Individual differences in both number and cumulative area precision (measured by accuracy on the magnitude comparison tasks) correlated with interindividual variability in math competence, particularly advanced arithmetic and geometry, even after accounting for general aspects of intelligence. Moreover, analyses revealed that whereas number precision contributed unique variance to advanced arithmetic, cumulative area precision contributed unique variance to geometry. Taken together, these results provide evidence for shared and unique contributions of nonsymbolic number and cumulative area representations to formally taught mathematics. More broadly, they suggest that uniquely human branches of mathematics interface with an evolutionarily primitive general magnitude system, which includes partially overlapping representations of numerical and nonnumerical magnitude. PMID:23091023
Belviranli, Muaz; Okudan, Nilsel; Kabak, Banu
2017-07-19
The objective of the study was to determine the effects of acute high-intensity interval training (HIIT) on hematological parameters in sedentary men. Ten healthy, non-smoker, and sedentary men aged between 18 and 24 years participated in the study. All subjects performed four Wingate tests with 4 min intervals between the tests. Blood samples were collected at pre-exercise, immediately after, 3 and 6 h after the fourth Wingate test. Hematological parameters were analyzed in these samples. The results showed that hematocrit percentage, hemoglobin values, red cell count, mean cell volume, platelet count, total white cell count, and counts of the white cell subgroups increased immediately after the acute HIIT and their values began to return to resting levels 3 h after exercise, and completely returned to resting levels 6 h after exercise. In conclusion, acute HIIT causes an inflammatory response in blood.
Ultraviolet Communication for Medical Applications
2013-06-01
sky was clear and no moonlight was visible during testing. There was light fog and high pollen count (9 grains per m3), and relative humidity was...improved LED light source was evaluated outdoors using the test bench system at a range of 50 m, and received photon counts were consistent with...bench system at a range of 50 m, and received photon counts were consistent with medium data rate communication. Future Phase II efforts will develop
NASA Astrophysics Data System (ADS)
Caudevilla, Oriol; Zhou, Wei; Stoupin, Stanislav; Verman, Boris; Brankov, J. G.
2016-09-01
Analyzer-based X-ray phase contrast imaging (ABI) belongs to a broader family of phase-contrast (PC) X-ray imaging modalities. Unlike the conventional X-ray radiography, which measures only X-ray absorption, in PC imaging one can also measures the X-rays deflection induced by the object refractive properties. It has been shown that refraction imaging provides better contrast when imaging the soft tissue, which is of great interest in medical imaging applications. In this paper, we introduce a simulation tool specifically designed to simulate the analyzer-based X-ray phase contrast imaging system with a conventional polychromatic X-ray source. By utilizing ray tracing and basic physical principles of diffraction theory our simulation tool can predicting the X-ray beam profile shape, the energy content, the total throughput (photon count) at the detector. In addition we can evaluate imaging system point-spread function for various system configurations.
Health Monitor for Multitasking, Safety-Critical, Real-Time Software
NASA Technical Reports Server (NTRS)
Zoerner, Roger
2011-01-01
Health Manager can detect Bad Health prior to a failure occurring by periodically monitoring the application software by looking for code corruption errors, and sanity-checking each critical data value prior to use. A processor s memory can fail and corrupt the software, or the software can accidentally write to the wrong address and overwrite the executing software. This innovation will continuously calculate a checksum of the software load to detect corrupted code. This will allow a system to detect a failure before it happens. This innovation monitors each software task (thread) so that if any task reports "bad health," or does not report to the Health Manager, the system is declared bad. The Health Manager reports overall system health to the outside world by outputting a square wave signal. If the square wave stops, this indicates that system health is bad or hung and cannot report. Either way, "bad health" can be detected, whether caused by an error, corrupted data, or a hung processor. A separate Health Monitor Task is started and run periodically in a loop that starts and stops pending on a semaphore. Each monitored task registers with the Health Manager, which maintains a count for the task. The registering task must indicate if it will run more or less often than the Health Manager. If the task runs more often than the Health Manager, the monitored task calls a health function that increments the count and verifies it did not go over max-count. When the periodic Health Manager runs, it verifies that the count did not go over the max-count and zeroes it. If the task runs less often than the Health Manager, the periodic Health Manager will increment the count. The monitored task zeroes the count, and both the Health Manager and monitored task verify that the count did not go over the max-count.
Al-Najar, Amr; Kaufmann, Sascha; Boy, Soenke; Naumann, Carsten Maik; Jünemann, Peter-Klaus; van der Horst, Christof
2011-01-01
Objective: Our objective was to establish the feasibility of combining 2 minimally invasive procedures in patients with failed primary treatment (male sling) in post-prostatectomy incontinence (PPI) patients. Methods: From January 2007 to July 2008, 40 men with PPI were implanted with a suburethral tape (2 patients with Seratim, 3 with I-Stop and 35 with Advance). The median preoperative pad count was 4 (range 2–10). Prior to sling placement, 6 patients had undergone ProACT implantation. Of these, 4 patients required explantation due to balloon migration and 2 patients had their balloons kept in situ, with the balloons deflated. Results: Twenty-five patients were socially continent at this time. Fifteen patients (37.5%) did not improve or their improvement was not significant. These patients had a preoperative pad count between 7 and 10. Two of these patients had prostate adjustable continence therapy (ProACT) systems still in place. By gradually filling the balloons to 3 mL, both of these patients achieved complete continence, which was maintained at a mean follow-up of 8.5 months. Three patients with prior pelvic irradiation received an artificial urinary sphincter and achieved continence at mean follow-up of 8.3 months. The remaining 10 patients received a ProACT system in addition to the already implanted sling. After appropriate healing and filling of the balloons (average balloon volume 5 mL), all 10 patients reached complete continence; they were pad-free at a mean follow-up of 6 months (range 3–9). Conclusions: The combination of ProACT and a suburethral tape was demonstrated to be a possible treatment option in recurrent or persistent PPI. PMID:21470536
A system for the measurement of delayed neutrons and gammas from special nuclear materials
Andrews, M. T.; Corcoran, E. C.; Goorley, J. T.; ...
2014-11-27
The delayed neutron counting (DNC) system at the Royal Military College of Canada has been upgraded to accommodate concurrent delayed neutron and gamma measurements. This delayed neutron and gamma counting (DNGC) system uses a SLOWPOKE-2 reactor to irradiate fissile materials before their transfer to a counting arrangement consisting of six ³He and one HPGe detector. The application of this system is demonstrated in an example where delayed neutron and gamma emissions are used in complement to examine ²³³U content and determine fissile mass with an average relative error and accuracy of -2.2 and 1.5 %, respectively.
People counting and re-identification using fusion of video camera and laser scanner
NASA Astrophysics Data System (ADS)
Ling, Bo; Olivera, Santiago; Wagley, Raj
2016-05-01
We present a system for people counting and re-identification. It can be used by transit and homeland security agencies. Under FTA SBIR program, we have developed a preliminary system for transit passenger counting and re-identification using a laser scanner and video camera. The laser scanner is used to identify the locations of passenger's head and shoulder in an image, a challenging task in crowed environment. It can also estimate the passenger height without prior calibration. Various color models have been applied to form color signatures. Finally, using a statistical fusion and classification scheme, passengers are counted and re-identified.
Driscoll, Jonathan D.; Shih, Andy Y.; Iyengar, Satish; Field, Jeffrey J.; White, G. Allen; Squier, Jeffrey A.; Cauwenberghs, Gert
2011-01-01
We present a high-speed photon counter for use with two-photon microscopy. Counting pulses of photocurrent, as opposed to analog integration, maximizes the signal-to-noise ratio so long as the uncertainty in the count does not exceed the gain-noise of the photodetector. Our system extends this improvement through an estimate of the count that corrects for the censored period after detection of an emission event. The same system can be rapidly reconfigured in software for fluorescence lifetime imaging, which we illustrate by distinguishing between two spectrally similar fluorophores in an in vivo model of microstroke. PMID:21471395
Track analysis of laser-illuminated etched track detectors using an opto-digital imaging system
NASA Astrophysics Data System (ADS)
Eghan, Moses J.; Buah-Bassuah, Paul K.; Oppon, Osborne C.
2007-11-01
An opto-digital imaging system for counting and analysing tracks on a LR-115 detector is described. One batch of LR-115 track detectors was irradiated with Am-241 for a determined period and distance for linearity test and another batch was exposed to radon gas. The laser-illuminated etched track detector area was imaged, digitized and analysed by the system. The tracks that were counted on the opto-digital system with the aid of media cybernetics software as well as spark gap counter showed comparable track density results ranging between 1500 and 2750 tracks cm-2 and 65 tracks cm-2 in the two different batch detector samples with 0.5% and 1% track counts, respectively. Track sizes of the incident alpha particles from the radon gas on the LR-115 detector demonstrating different track energies are statistically and graphically represented. The opto-digital imaging system counts and measures other track parameters at an average process time of 3-5 s.
4D light-field sensing system for people counting
NASA Astrophysics Data System (ADS)
Hou, Guangqi; Zhang, Chi; Wang, Yunlong; Sun, Zhenan
2016-03-01
Counting the number of people is still an important task in social security applications, and a few methods based on video surveillance have been proposed in recent years. In this paper, we design a novel optical sensing system to directly acquire the depth map of the scene from one light-field camera. The light-field sensing system can count the number of people crossing the passageway, and record the direction and intensity of rays at a snapshot without any assistant light devices. Depth maps are extracted from the raw light-ray sensing data. Our smart sensing system is equipped with a passive imaging sensor, which is able to naturally discern the depth difference between the head and shoulders for each person. Then a human model is built. Through detecting the human model from light-field images, the number of people passing the scene can be counted rapidly. We verify the feasibility of the sensing system as well as the accuracy by capturing real-world scenes passing single and multiple people under natural illumination.
Digital computing cardiotachometer
NASA Technical Reports Server (NTRS)
Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)
1973-01-01
A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.
Assessment of Intervertebral Disc Degeneration Based on Quantitative MRI Analysis: an in vivo study
Grunert, Peter; Hudson, Katherine D.; Macielak, Michael R.; Aronowitz, Eric; Borde, Brandon H.; Alimi, Marjan; Njoku, Innocent; Ballon, Douglas; Tsiouris, Apostolos John; Bonassar, Lawrence J.; Härtl, Roger
2015-01-01
Study design Animal experimental study Objective To evaluate a novel quantitative imaging technique for assessing disc degeneration. Summary of Background Data T2-relaxation time (T2-RT) measurements have been used to quantitatively assess disc degeneration. T2 values correlate with the water content of inter vertebral disc tissue and thereby allow for the indirect measurement of nucleus pulposus (NP) hydration. Methods We developed an algorithm to subtract out MRI voxels not representing NP tissue based on T2-RT values. Filtered NP voxels were used to measure nuclear size by their amount and nuclear hydration by their mean T2-RT. This technique was applied to 24 rat-tail intervertebral discs’ (IVDs), which had been punctured with an 18-gauge needle according to different techniques to induce varying degrees of degeneration. NP voxel count and average T2-RT were used as parameters to assess the degeneration process at 1 and 3 months post puncture. NP voxel counts were evaluated against X-ray disc height measurements and qualitative MRI studies based on the Pfirrmann grading system. Tails were collected for histology to correlate NP voxel counts to histological disc degeneration grades and to NP cross-sectional area measurements. Results NP voxel count measurements showed strong correlations to qualitative MRI analyses (R2=0.79, p<0.0001), histological degeneration grades (R2=0.902, p<0.0001) and histological NP cross-sectional area measurements (R2=0.887, p<0.0001). In contrast to NP voxel counts, the mean T2-RT for each punctured group remained constant between months 1 and 3. The mean T2-RTs for the punctured groups did not show a statistically significant difference from those of healthy IVDs (63.55ms ±5.88ms month 1 and 62.61ms ±5.02ms) at either time point. Conclusion The NP voxel count proved to be a valid parameter to quantitatively assess disc degeneration in a needle puncture model. The mean NP T2-RT does not change significantly in needle-puncture induced degenerated IVDs. IVDs can be segmented into different tissue components according to their innate T2-RT. PMID:24384655
Service-oriented architecture for the ARGOS instrument control software
NASA Astrophysics Data System (ADS)
Borelli, J.; Barl, L.; Gässler, W.; Kulas, M.; Rabien, Sebastian
2012-09-01
The Advanced Rayleigh Guided ground layer Adaptive optic System, ARGOS, equips the Large Binocular Telescope (LBT) with a constellation of six rayleigh laser guide stars. By correcting atmospheric turbulence near the ground, the system is designed to increase the image quality of the multi-object spectrograph LUCIFER approximately by a factor of 3 over a field of 4 arc minute diameter. The control software has the critical task of orchestrating several devices, instruments, and high level services, including the already existing adaptive optic system and the telescope control software. All these components are widely distributed over the telescope, adding more complexity to the system design. The approach used by the ARGOS engineers is to write loosely coupled and distributed services under the control of different ownership systems, providing a uniform mechanism to offer, discover, interact and use these distributed capabilities. The control system counts with several finite state machines, vibration and flexure compensation loops, and safety mechanism, such as interlocks, aircraft, and satellite avoidance systems.
NASA Astrophysics Data System (ADS)
Prochazka, Ivan; Kodet, Jan; Eckl, Johann; Blazej, Josef
2017-10-01
We are reporting on the design, construction, and performance of a photon counting detector system, which is based on single photon avalanche diode detector technology. This photon counting device has been optimized for very high timing resolution and stability of its detection delay. The foreseen application of this detector is laser ranging of space objects, laser time transfer ground to space and fundamental metrology. The single photon avalanche diode structure, manufactured on silicon using K14 technology, is used as a sensor. The active area of the sensor is circular with 200 μm diameter. Its photon detection probability exceeds 40% in the wavelength range spanning from 500 to 800 nm. The sensor is operated in active quenching and gating mode. A new control circuit was optimized to maintain high timing resolution and detection delay stability. In connection to this circuit, timing resolution of the detector is reaching 20 ps FWHM. In addition, the temperature change of the detection delay is as low as 70 fs/K. As a result, the detection delay stability of the device is exceptional: expressed in the form of time deviation, detection delay stability of better than 60 fs has been achieved. Considering the large active area aperture of the detector, this is, to our knowledge, the best timing performance reported for a solid state photon counting detector so far.
Gupta, Parul; Narang, Manish; Gomber, Sunil; Saha, Rumpa
2017-05-01
There are several case reports of quinine-induced thrombocytopenia but no clinical trials to ascertain its incidence and significance in severe malaria. The primary objective was to assess the effect of quinine on the platelet count in children with severe malaria and to compare it with artesunate combination therapy (ACT), and the secondary objective was to assess outcome of treatment with quinine and ACT. An open-labelled, randomised, controlled trial was undertaken in 100 children aged 6 months to 12 years who were diagnosed with malaria by microscopy and/or rapid diagnostic test kits with at least one WHO clinical or laboratory criterion for severe malaria. All subjects were commenced on either quinine or ACT. Clindamycin was added to artesunate as a combination drug (ACT). It was also given to patients on quinine to avoid its confounding effect on the results. Platelet counts were undertaken every 24 hours for 7 consecutive days, temperature and coma score (Blantyre coma score ≥3 in children <4 years or Glasgow coma score ≥13 in children >4 years) was recorded 6-hourly and peripheral smears were taken 12-hourly until two consecutively negative smears were obtained. The primary outcome was a fall in the platelet count by ≥20% from the time of drug initiation until day 7. The secondary outcome was comparison of the efficacy, parasite clearance time, fever clearance time, coma recovery time and adverse effects of quinine vs ACT. 30.4% patients in the quinine group (n = 48) had ≥20% fall in platelet count and 10.8% of patients in the ACT group (n = 46) (P = 0.02). Despite the fall in platelet count, there was no bleeding. The efficacy of ACT was significantly better than quinine but the other treatment outcomes showed insignificant difference. Quinine should be used with caution in patients with severe malaria because of the potential risk of quinine-induced thrombocytopenia.
Owen, Christopher G; Nightingale, Claire M; Rudnicka, Alicja R; Cook, Derek G; Ekelund, Ulf; Whincup, Peter H
2009-01-01
Background Ethnic differences in physical activity in children in the UK have not been accurately assessed. We made objective measurements of physical activity in 9–10-year-old British children of South Asian, black African–Caribbean and white European origin. Methods Cross-sectional study of urban primary school children (2006–07). Actigraph-GT1M activity monitors were worn by 2071 children during waking hours on at least 1 full day. Ethnic differences in mean daily activity [counts, counts per minute of registered time (CPM) and steps] were adjusted for age, gender, day of week and month. Multilevel modelling allowed for repeated days within individual and clustering within school. Results In white Europeans, mean daily counts, CPM and mean daily steps were 394 785, 498 and 10 220, respectively. South Asian and black Caribbean children recorded more registered time per day than white Europeans (34 and 36 min, respectively). Compared with white Europeans, South Asians recorded 18 789 fewer counts [95% confidence interval (CI) 6390–31 187], 41 fewer CPM 95% CI 26–57) and 905 fewer steps (95% CI 624–1187). Black African–Caribbeans recorded 25 359 more counts (95% CI 14 273–36 445), and similar CPM, but fewer steps than white Europeans. Girls recorded less activity than boys in all ethnic groups, with 74 782 fewer counts (95% CI 66 665–82 899), 84 fewer CPM (95% CI 74–95) and 1484 fewer steps (95% CI 1301–1668). Conclusion British South Asian children have lower objectively measured physical activity levels than European whites and black African–Caribbeans. PMID:19377098
Kiess, A S; Hirai, J H; Triplett, M D; Parker, H M; McDaniel, C D
2016-08-01
The use of antibiotics in poultry is being heavily scrutinized, therefore alternatives such as probiotics are being investigated. Lactobacilli spp. are a commonly used bacteria in formulating probiotics, and the addition of Lactobacilli to broiler diets has demonstrated increased growth rates, stimulated immune systems, and reduced pathogen loads in the gastro-intestinal tract ( GI: ) tract. However, previous research has shown that when rooster semen is directly exposed to Lactobacillus acidophilus (L. acidophilus) sperm quality is reduced. Therefore, the objective of the current study was to determine if oral administration of L. acidophilus increases the concentration of Lactobacilli in semen as well as the cloaca. A total of 30 roosters were used: 15 roosters were gavaged with 1X PBS (Control) and 15 roosters were gavaged with 10(7) cfu/mL of L. acidophilus (Treated). All roosters were gavaged for 14 consecutive days. Semen was collected on a 3 d interval, and cloacal swabs were collected on a 2 d interval, beginning on the first day prior to oral administration. Semen and cloacal swabs were serial diluted, and 100 μL of each dilution was then plated on Man, Rogosa, Sharpe ( MRS: ) agar plates. All plates were incubated for 48 h at 37°C under anaerobic conditions and counted. All Lactobacilli counts were first log transformed, then log transformed (day 0) pre-counts were subtracted from the log transformed day counts providing log differences for the analysis. Seminal Lactobacilli counts were not altered by treatments. However, the main effect of treatment (P = 0.026) for cloacal counts indicated that roosters gavaged with Lactobacilli yielded higher counts than the controls. Additionally, cloaca samples also demonstrated a treatment by day interaction trend (P = 0.082), where Lactobacilli was higher in the L. acidophilus gavaged roosters than the controls only on days 3, 5, 13, and 15. In conclusion, the addition of L. acidophilus to the male breeder diet over extended periods may increase concentrations of Lactobacilli in the cloaca even higher than the concentrations observed in this study. If Lactobacilli reaches high enough concentrations in the cloaca, then sperm quality may be impacted which could lead to poor fertility within the breeder flock. © 2016 Poultry Science Association Inc.
Physical activity among children: objective measurements using Fitbit One® and ActiGraph.
Hamari, Lotta; Kullberg, Tiina; Ruohonen, Jukka; Heinonen, Olli J; Díaz-Rodríguez, Natalia; Lilius, Johan; Pakarinen, Anni; Myllymäki, Annukka; Leppänen, Ville; Salanterä, Sanna
2017-04-20
Self-quantification of health parameters is becoming more popular; thus, the validity of the devices requires assessments. The aim of this study was to evaluate the validity of Fitbit One step counts (Fitbit Inc., San Francisco, CA, USA) against Actigraph wActisleep-BT step counts (ActiGraph, LLC, Pensacola, FL, USA) for measuring habitual physical activity among children. The study was implemented as a cross-sectional experimental design in which participants carried two waist-worn activity monitors for five consecutive days. The participants were chosen with a purposive sampling from three fourth grade classes (9-10 year olds) in two comprehensive schools. Altogether, there were 34 participants in the study. From these, eight participants were excluded from the analysis due to erroneous data. Primary outcome measures for step counts were Fitbit One and Actigraph wActisleep-BT. The supporting outcome measures were based on activity diaries and initial information sheets. Classical Bland-Altman plots were used for reporting the results. The average per-participant daily difference between the step counts from the two devices was 1937. The range was [116, 5052]. Fitbit One gave higher step counts for all but the least active participant. According to a Bland-Altman plot, the hourly step counts had a relative large mean bias across participants (161 step counts). The differences were partially explained by activity intensity: higher intensity denoted higher differences, and light intensity denoted lower differences. Fitbit One step counts are comparable to Actigraph step counts in a sample of 9-10-year-old children engaged in habitual physical activity in sedentary and light physical activity intensities. However, in moderate-to-vigorous physical activity, Fitbit One gives higher step counts when compared to Actigraph.
Singh, Surender; Nair, Vinod; Gupta, Yogendra K.
2012-01-01
Objectives: To study the effect of acute and repeated dose administration of lyophilized aqueous extract of the dried fruits of Tribulus terrestris (LAET) on sexual function in sexually sluggish male albino rats. Materials and Methods: Aphrodisiac activity of the test drug was evaluated in terms of exhibited sexual behavior. In order to assess the effect of chronic T. terrestris exposure on the hypothalamus--pituitary--gonadal axis, testosterone level estimation and sperm count were carried out. Twenty-eight-day oral toxicity studies were carried out to evaluate the long-term effects of the LAET administration on different body systems. Results: A dose-dependent improvement in sexual behavior was observed with the LAET treatment as characterized by an increase in mount frequency, intromission frequency, and penile erection index, as well as a decrease in mount latency, intromission latency, and ejaculatory latency. The enhancement of sexual behavior was more prominent on chronic administration of LAET. Chronic administration of LAET produced a significant increase in serum testosterone levels with no significant effect on the sperm count. No overt body system dysfunctions were observed in 28-day oral toxicity study. Conclusions: Findings of the present study validate the traditional use of T. terrestris as a sexual enhancer in the management of sexual dysfunction in males. PMID:22368416
A Microbial Assessment Scheme to measure microbial performance of Food Safety Management Systems.
Jacxsens, L; Kussaga, J; Luning, P A; Van der Spiegel, M; Devlieghere, F; Uyttendaele, M
2009-08-31
A Food Safety Management System (FSMS) implemented in a food processing industry is based on Good Hygienic Practices (GHP), Hazard Analysis Critical Control Point (HACCP) principles and should address both food safety control and assurance activities in order to guarantee food safety. One of the most emerging challenges is to assess the performance of a present FSMS. The objective of this work is to explain the development of a Microbial Assessment Scheme (MAS) as a tool for a systematic analysis of microbial counts in order to assess the current microbial performance of an implemented FSMS. It is assumed that low numbers of microorganisms and small variations in microbial counts indicate an effective FSMS. The MAS is a procedure that defines the identification of critical sampling locations, the selection of microbiological parameters, the assessment of sampling frequency, the selection of sampling method and method of analysis, and finally data processing and interpretation. Based on the MAS assessment, microbial safety level profiles can be derived, indicating which microorganisms and to what extent they contribute to food safety for a specific food processing company. The MAS concept is illustrated with a case study in the pork processing industry, where ready-to-eat meat products are produced (cured, cooked ham and cured, dried bacon).
Sediment bacterial indicators in an urban shellfishing subestuary of the lower Chesapeake Bay.
Erkenbrecher, C W
1981-01-01
The objectives of this study were to document the spatial and temporal distributions and compositions of bacteria in the sediments and overlying waters of an important urban shellfishing area in the lower Chesapeake Bay region, the Lynnhaven Estuary. Marked fluctuations were observed in the date of many of the physicochemical parameters and the indicator bacteria. The higher-salinity water and coarser sediment of the inlet site showed lower overall bacterial densities than did the headwater sites, where freshwater runoff and decreased tidal action were characteristic. Densities of benthic indicator bacteria, when expressed on a volumetric basis, were significantly greater than counts in the overlying waters. These counts were indicative of a fecally polluted system and were well above the safe maximum limits for shellfish-growing waters. Significantly fewer total and fecal bacteria were observed in both the water and the sediment during the warm months of May, July, and August. The primary sources of the Lynnhaven's bacterial pollution appeared to be typical of urban and agricultural runoff, although failure of septic tank systems was suspected as a problem in the Lynnhaven's western branch. These results illustrated that sediments in shellfishing areas could serve as a reservoir for high densities of indicator bacteria and that, potentially, pathogens could pose a health hazard. PMID:7294785
Gomez-Sanchez, Leticia; García-Ortiz, Luis; Recio-Rodríguez, José I.; Patino-Alonso, Maria C.; Agudo-Conde, Cristina; Rigo, Fernando; Ramos, Rafel; Martí, Ruth; Gomez-Marcos, Manuel A.
2015-01-01
Objectives We investigated the relationship between leukocyte subtype counts and vascular structure and function based on carotid intima-media thickness, pulse wave velocity, central augmentation index and cardio-ankle vascular index by gender in intermediate cardiovascular risk patients. Methods This study analyzed 500 subjects who were included in the MARK study, aged 35 to 74 years (mean: 60.3±8.4), 45.6% women. Measurement: Brachial ankle Pulse Wave Velocity (ba-PWV) estimate by equation, Cardio-AnkleVascular Index (CAVI) using the VaSera device and Carotid ultrasound was used to measure carotid Intima Media Thickness (IMT). The Mobil-O-Graph was used to measure the Central Augmentation Index (CAIx). Results Total leukocyte, neutrophil and monocyte counts were positively correlated with IMT (p < 0.01) in men. Monocyte count was positively correlated with CAIx in women (p < 0.01). In a multiple linear regression analysis, the IMT mean maintained a positive association with the neutrophil count (β = 1.500, p = 0.007) in men. CAIx maintained a positive association with the monocyte count (β = 2.445, p = 0.022) in women. Conclusion The results of this study suggest that the relationship between subtype circulating leukocyte counts and vascular structure and function, although small, may be different by gender. In men, the neutrophil count was positively correlated with IMT and in women, the monocyte count with CAIx, in a large sample of intermediate-risk patients. These association were maintained after adjusting for age and other confounders. Trial Registration ClinicalTrials.gov NCT01428934 PMID:25885665
Use of an activity monitor to detect response to treatment in dogs with osteoarthritis
Brown, Dorothy Cimino; Boston, Raymond C.; Farrar, John T.
2010-01-01
Objective To determine whether an activity monitor (AM) could be used to detect changes in activity in dogs with osteoarthritis treated with carprofen or a placebo. Design Randomized controlled trial. Animals 70 dogs with no clinically important abnormalities other than osteoarthritis for which they were not currently being treated. Procedures Dogs wore an AM continuously for 21 days. On days 8 through 21, the dogs were treated with carprofen (n = 35) or a placebo (35). Total activity counts for days 1 through 7 (baseline) were compared with total activity counts for days 15 through 21 (endpoint). The change in total activity count from baseline to endpoint was assessed within each treatment group as well as between groups. Linear regression analysis was performed to test for an association between treatment and percentage change in activity counts while controlling for other variables. Results For placebo-treated dogs, median baseline total activity count was not significantly different from median endpoint total activity count (1,378,408 vs 1,310,112, respectively). For dogs receiving carprofen, there was a significant increase in median activity count from baseline to endpoint (1,276,427 vs 1,374,133). When age and baseline activity counts were controlled for, dogs in the carpofen-treated group had a 20% increase in activity counts, compared with placebo-treated dogs (95% confidence interval, 10% to 26%). Conclusions and Clinical Relevance Results suggested that the AM used in the present study may be a valid outcome assessment tool for documenting improved activity associated with treatment in dogs with osteoarthritis. PMID:20590496
Klimowicz, M D; Nizanski, W; Batkowski, F; Savic, M A
2008-07-01
The aim of these experiments was to compare conventional, microscopic methods of evaluating pigeon sperm motility and concentration to those measured by computer-assisted sperm analysis (CASA system). Semen was collected twice a week from two groups of pigeons, each of 40 males (group I: meat-type breed; group II: fancy pigeon) using the lumbo-sacral and cloacal region massage method. Ejaculates collected in each group were diluted 1:100 in BPSE solution and divided into two equal samples. One sample was examined subjectively by microscope and the second one was analysed using CASA system. The sperm concentration was measured by CASA using the anti-collision (AC) system and fluorescent staining (IDENT). There were not any significant differences between the methods of evaluation of sperm concentration. High positive correlations in both groups were observed between the sperm concentration estimated by Thom counting chamber and AC (r=0.87 and r=0.91, respectively), and between the sperm concentration evaluated by Thom counting chamber and IDENT (r=0.85 and r=0.90, respectively). The mean values for CASA measurement of proportion of motile spermatozoa (MOT) and progressive movement (PMOT) were significantly lower than the values estimated subjectively in both groups of pigeons (p< or =0.05 and p< or =0.01, respectively). Positive correlations in MOT and PMOT were noted between both methods of evaluation. The CASA system is very rapid, objective and sensitive method in detecting subtle motility characteristics as well as sperm concentration and is recommended for future research into pigeon semen.
Zero adjusted models with applications to analysing helminths count data.
Chipeta, Michael G; Ngwira, Bagrey M; Simoonga, Christopher; Kazembe, Lawrence N
2014-11-27
It is common in public health and epidemiology that the outcome of interest is counts of events occurrence. Analysing these data using classical linear models is mostly inappropriate, even after transformation of outcome variables due to overdispersion. Zero-adjusted mixture count models such as zero-inflated and hurdle count models are applied to count data when over-dispersion and excess zeros exist. Main objective of the current paper is to apply such models to analyse risk factors associated with human helminths (S. haematobium) particularly in a case where there's a high proportion of zero counts. The data were collected during a community-based randomised control trial assessing the impact of mass drug administration (MDA) with praziquantel in Malawi, and a school-based cross sectional epidemiology survey in Zambia. Count data models including traditional (Poisson and negative binomial) models, zero modified models (zero inflated Poisson and zero inflated negative binomial) and hurdle models (Poisson logit hurdle and negative binomial logit hurdle) were fitted and compared. Using Akaike information criteria (AIC), the negative binomial logit hurdle (NBLH) and zero inflated negative binomial (ZINB) showed best performance in both datasets. With regards to zero count capturing, these models performed better than other models. This paper showed that zero modified NBLH and ZINB models are more appropriate methods for the analysis of data with excess zeros. The choice between the hurdle and zero-inflated models should be based on the aim and endpoints of the study.
De Cocker, K; Cardon, G; De Bourdeaudhuij, I
2006-01-01
Objectives To evaluate if inexpensive Stepping Meters are valid in counting steps in adults in free living conditions. Methods For six days, 35 healthy volunteers wore a criterion Yamax Digiwalker and five Stepping Meters every day until all 973 pedometers had been tested. Steps were recorded daily, and the differences between counts from the Digiwalker and the Stepping Meter were expressed as a percentage of the valid value of the Digiwalker step counts. The criterion used to determine if a Stepping Meter was valid was a maximum deviation of 10% from the Digiwalker step counts. Results A total of 252 (25.9%) Stepping Meters met the criterion, whereas 74.1% made an overestimation or underestimation of more than 10%. In more than one third (36.6%) of the invalid Stepping Meters, the deviation was greater than 50%. Most (64.8%) of the invalid pedometers overestimated the actual steps taken. Conclusions Inexpensive Stepping Meters cannot be used in community interventions as they will give participants the wrong message. PMID:16790485
Alimenti, Federico; Bonafoni, Stefania; Roselli, Luca
2017-01-01
Controlled measurements by a low-cost single-pixel microwave radiometer operating at 12.65 GHz were carried out to assess the detection and counting capability for targets warmer than the surroundings. The adopted reference test targets were pre-warmed water and oil; and a hand, both naked and wearing a glove. The results showed the reliability of microwave radiometry for counting operations under controlled conditions, and its effectiveness at detecting even warm targets masked by unheated dielectric layers. An electromagnetic model describing the scenario sensed by the radiometer antenna is proposed, and comparison with the experimental observations shows a good agreement. The measurements prove that reliable counting is enabled by an antenna temperature increment, for each target sample added, of around 1 K. Starting from this value, an analysis of the antenna filling factor was performed to provide an instrument useful for evaluating real applicability in many practical situations. This study also allows the direct people counting problem to be addressed, providing preliminary operational indications, reference numbers and experimental validation. PMID:28613264
Berger, Philip; Messner, Michael J; Crosby, Jake; Vacs Renwick, Deborah; Heinrich, Austin
2018-05-01
Spore reduction can be used as a surrogate measure of Cryptosporidium natural filtration efficiency. Estimates of log10 (log) reduction were derived from spore measurements in paired surface and well water samples in Casper Wyoming and Kearney Nebraska. We found that these data were suitable for testing the hypothesis (H 0 ) that the average reduction at each site was 2 log or less, using a one-sided Student's t-test. After establishing data quality objectives for the test (expressed as tolerable Type I and Type II error rates), we evaluated the test's performance as a function of the (a) true log reduction, (b) number of paired samples assayed and (c) variance of observed log reductions. We found that 36 paired spore samples are sufficient to achieve the objectives over a wide range of variance, including the variances observed in the two data sets. We also explored the feasibility of using smaller numbers of paired spore samples to supplement bioparticle counts for screening purposes in alluvial aquifers, to differentiate wells with large volume surface water induced recharge from wells with negligible surface water induced recharge. With key assumptions, we propose a normal statistical test of the same hypothesis (H 0 ), but with different performance objectives. As few as six paired spore samples appear adequate as a screening metric to supplement bioparticle counts to differentiate wells in alluvial aquifers with large volume surface water induced recharge. For the case when all available information (including failure to reject H 0 based on the limited paired spore data) leads to the conclusion that wells have large surface water induced recharge, we recommend further evaluation using additional paired biweekly spore samples. Published by Elsevier GmbH.
Objective assessment of activity in older adults at risk for mobility disability.
Marsh, Anthony P; Vance, Rachel M; Frederick, Tera L; Hesselmann, Sarah A; Rejeski, W Jack
2007-06-01
The purpose of this study was to evaluate the validity of three objective measures of physical activity (Accusplit Eagle 120 mechanical pedometer (AE120), NL-2000 electronic pedometer, and IDEEA pattern-recognition device) that varied in their levels of sophistication, among older adults at risk for mobility disability. In addition, we examined the potential influences of gait speed and body mass index (BMI) on step count accuracy. Step counts recorded on the three devices were compared against manual step counts made by two investigators as each participant walked 131 m around an indoor track at their preferred walking speed (N=29; 75.8+/-4.2 yr). Gait speed was determined by dividing total distance walked by time to completion. BMI was calculated from height and body mass measurements. All three devices significantly underestimated steps taken (AE120=22.8+/-53.9 steps; NL-2000=4.0+/-5.8 steps; IDEEA=5.6+/-7.8 steps), but there was no significant difference between devices (P=0.084). Steps counted by the AE120, NL-2000, and IDEEA were significantly correlated with manual step counts (r=0.508, 0.980, and 0.965, respectively; P
A big data approach to the development of mixed-effects models for seizure count data.
Tharayil, Joseph J; Chiang, Sharon; Moss, Robert; Stern, John M; Theodore, William H; Goldenholz, Daniel M
2017-05-01
Our objective was to develop a generalized linear mixed model for predicting seizure count that is useful in the design and analysis of clinical trials. This model also may benefit the design and interpretation of seizure-recording paradigms. Most existing seizure count models do not include children, and there is currently no consensus regarding the most suitable model that can be applied to children and adults. Therefore, an additional objective was to develop a model that accounts for both adult and pediatric epilepsy. Using data from SeizureTracker.com, a patient-reported seizure diary tool with >1.2 million recorded seizures across 8 years, we evaluated the appropriateness of Poisson, negative binomial, zero-inflated negative binomial, and modified negative binomial models for seizure count data based on minimization of the Bayesian information criterion. Generalized linear mixed-effects models were used to account for demographic and etiologic covariates and for autocorrelation structure. Holdout cross-validation was used to evaluate predictive accuracy in simulating seizure frequencies. For both adults and children, we found that a negative binomial model with autocorrelation over 1 day was optimal. Using holdout cross-validation, the proposed model was found to provide accurate simulation of seizure counts for patients with up to four seizures per day. The optimal model can be used to generate more realistic simulated patient data with very few input parameters. The availability of a parsimonious, realistic virtual patient model can be of great utility in simulations of phase II/III clinical trials, epilepsy monitoring units, outpatient biosensors, and mobile Health (mHealth) applications. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.
Validation of accelerometer wear and nonwear time classification algorithm.
Choi, Leena; Liu, Zhouwen; Matthews, Charles E; Buchowski, Maciej S
2011-02-01
the use of movement monitors (accelerometers) for measuring physical activity (PA) in intervention and population-based studies is becoming a standard methodology for the objective measurement of sedentary and active behaviors and for the validation of subjective PA self-reports. A vital step in PA measurement is the classification of daily time into accelerometer wear and nonwear intervals using its recordings (counts) and an accelerometer-specific algorithm. the purpose of this study was to validate and improve a commonly used algorithm for classifying accelerometer wear and nonwear time intervals using objective movement data obtained in the whole-room indirect calorimeter. we conducted a validation study of a wear or nonwear automatic algorithm using data obtained from 49 adults and 76 youth wearing accelerometers during a strictly monitored 24-h stay in a room calorimeter. The accelerometer wear and nonwear time classified by the algorithm was compared with actual wearing time. Potential improvements to the algorithm were examined using the minimum classification error as an optimization target. the recommended elements in the new algorithm are as follows: 1) zero-count threshold during a nonwear time interval, 2) 90-min time window for consecutive zero or nonzero counts, and 3) allowance of 2-min interval of nonzero counts with the upstream or downstream 30-min consecutive zero-count window for detection of artifactual movements. Compared with the true wearing status, improvements to the algorithm decreased nonwear time misclassification during the waking and the 24-h periods (all P values < 0.001). the accelerometer wear or nonwear time algorithm improvements may lead to more accurate estimation of time spent in sedentary and active behaviors.
Heikinheimo, Terttu; Putaala, Jukka; Haapaniemi, Elena; Kaste, Markku; Tatlisumak, Turgut
2015-02-01
Limited data exist on the associated factors and correlation of leucocyte count to outcome in young adults with first-ever ischaemic stroke. Our objectives were to investigate factors associated with elevated leucocyte count and whether there is correlation between leucocyte count and short- and long-term outcomes. Of our database of 1008 consecutive patients aged 15 to 49, we included those with leucocyte count measured within the first two days from stroke onset. Outcomes were three-month and long-term disability, death, and vascular events. Linear regression was used to explore baseline variables associated with leucocyte count. Logistic regression and Cox proportional models studied the association between leucocyte count and clinical outcomes. In our study cohort of 781 patients (61.7% males; mean age 41.4 years), mean leucocyte count was high: 8.8 ± 3.1 × 10(9) cells/L (Reference range: 3.4-8.2 × 10(9) cells/L). Higher leucocyte levels were associated with dyslipidaemia, smoking, peripheral arterial disease, stroke severity, and lesion size. After adjustment for age, gender, relevant risk factors, both continuous leucocyte count and the highest quartile of leucocyte count were independently associated with unfavourable three-month outcome. Regarding events in the long-term (follow-up 8.1 ± 4.2 years in survivors), no association between leucocyte count and the event risks appeared. Among young stroke patients, high leucocyte count was a common finding. It was associated with vascular disease and its risk factors as well as severity of stroke, but it was also independently associated with unfavourable three-month outcome in these patients. There was no association with the long-term outcome. [Correction added on 31 October 2013 after first online publication: In the Results section of the Abstract, the cohort of 797 patients in this study was corrected to 781 patients.]. © 2013 The Authors. International Journal of Stroke © 2013 World Stroke Organization.
Policy on Counting Superseded Checklists in StATS
As we proceed with implementing the State Authorization Tracking System (StATS), and develop management reports based on data in StATS, we continue to identify issues dealing with what events should or should not be counted in the system.
Instruction manual for operating the Sensys System for temporary traffic counts
DOT National Transportation Integrated Search
2010-01-01
This instruction manual provides information and the procedures for using the Sensys System, which was initially designed to operate in a server controlled network, for temporary traffic counts. The instructions will allow the user to fully understan...
Star counts and visual extinctions in dark nebulae
NASA Technical Reports Server (NTRS)
Dickman, R. L.
1978-01-01
Application of star count techniques to the determination of visual extinctions in compact, fairly high-extinction dark nebulae is discussed. Particular attention is devoted to the determination of visual extinctions for a cloud having a possibly anomalous ratio of total to selective extinction. The techniques discussed are illustrated in application at two colors to four well-known compact dust clouds or Bok globules: Barnard 92, B 133, B 134, and B 335. Minimum masses and lower limits to the central extinction of these objects are presented.
Update on "What" and "Where" in Spatial Language: A New Division of Labor for Spatial Terms
ERIC Educational Resources Information Center
Landau, Barbara
2017-01-01
In this article, I revisit Landau and Jackendoff's (1993) paper, "What and where in spatial language and spatial cognition," proposing a friendly amendment and reformulation. The original paper emphasized the distinct geometries that are engaged when objects are represented as members of object kinds (named by count nouns), versus when…
Caldwell, Julie M.; Collins, Margaret H.; Stucke, Emily M.; Putnam, Philip E.; Franciosi, James P.; Kushner, Jonathan P.; Abonia, J. Pablo; Rothenberg, Marc E.
2014-01-01
Background The definition of eosinophilic gastritis (EG) is currently limited to histological EG based on the tissue eosinophil count. Objective We aimed to provide additional fundamental information about the molecular, histopathological, and clinical characteristics of EG. Methods Genome-wide transcript profiles and histological features of gastric biopsies as well as blood eosinophil numbers were analyzed in EG and control patients (n = 15 each). Results The peak gastric antrum eosinophil count was 282.7 ± 163.9 eosinophils/400X high-power field (HPF) in EG and 11.0 ± 8.5 eosinophils/HPF in control patients (P = 6.1 × 10−7). EG patients (87%) had co-existing eosinophilic inflammation in multiple gastrointestinal segments; the esophagus represented the most common secondary site. Elevated peripheral blood eosinophil numbers (EG 1.09 ± 0.88 × 103 [K]/μl vs. control 0.09 ± 0.08 K/μl, P = .0027) positively correlated with peak gastric eosinophil counts (Pearson r2 = .8102, P < .0001). MIB-1+ (proliferating), CD117+ (mast cells), and FOXP3+ cells (regulatory and/or activated T cells) were increased in EG. Transcript profiling revealed changes in 8% of the genome in EG gastric tissue. Only 7% of this EG transcriptome overlapped with the eosinophilic esophagitis (EoE) transcriptome. Significantly increased IL4, IL5, IL13, IL17, CCL26 and mast cell-specific transcripts and decreased IL33 were observed. Conclusion EG is a systemic disorder involving profound blood and gastrointestinal tract eosinophilia, Th2 immunity, and a conserved gastric transcriptome markedly distinct from the EoE transcriptome. The data herein define germane cellular and molecular pathways of EG and provide a basis for improving diagnosis and treatment. PMID:25234644
Yurt, Kıymet Kübra; Kivrak, Elfide Gizem; Altun, Gamze; Mohamed, Hamza; Ali, Fathelrahman; Gasmalla, Hosam Eldeen; Kaplan, Suleyman
2018-02-26
A quantitative description of a three-dimensional (3D) object based on two-dimensional images can be made using stereological methods These methods involve unbiased approaches and provide reliable results with quantitative data. The quantitative morphology of the nervous system has been thoroughly researched in this context. In particular, various novel methods such as design-based stereological approaches have been applied in neuoromorphological studies. The main foundations of these methods are systematic random sampling and a 3D approach to structures such as tissues and organs. One key point in these methods is that selected samples should represent the entire structure. Quantification of neurons, i.e. particles, is important for revealing degrees of neurodegeneration and regeneration in an organ or system. One of the most crucial morphometric parameters in biological studies is thus the "number". The disector counting method introduced by Sterio in 1984 is an efficient and reliable solution for particle number estimation. In order to obtain precise results by means of stereological analysis, counting items should be seen clearly in the tissue. If an item in the tissue cannot be seen, these cannot be analyzed even using unbiased stereological techniques. Staining and sectioning processes therefore play a critical role in stereological analysis. The purpose of this review is to evaluate current neuroscientific studies using optical and physical disector counting methods and to discuss their definitions and methodological characteristics. Although the efficiency of the optical disector method in light microscopic studies has been revealed in recent years, the physical disector method is more easily performed in electron microscopic studies. Also, we offered to readers summaries of some common basic staining and sectioning methods, which can be used for stereological techniques in this review. Copyright © 2018 Elsevier B.V. All rights reserved.
Anti-aliasing techniques in photon-counting depth imaging using GHz clock rates
NASA Astrophysics Data System (ADS)
Krichel, Nils J.; McCarthy, Aongus; Collins, Robert J.; Buller, Gerald S.
2010-04-01
Single-photon detection technologies in conjunction with low laser illumination powers allow for the eye-safe acquisition of time-of-flight range information on non-cooperative target surfaces. We previously presented a photon-counting depth imaging system designed for the rapid acquisition of three-dimensional target models by steering a single scanning pixel across the field angle of interest. To minimise the per-pixel dwelling times required to obtain sufficient photon statistics for accurate distance resolution, periodic illumination at multi- MHz repetition rates was applied. Modern time-correlated single-photon counting (TCSPC) hardware allowed for depth measurements with sub-mm precision. Resolving the absolute target range with a fast periodic signal is only possible at sufficiently short distances: if the round-trip time towards an object is extended beyond the timespan between two trigger pulses, the return signal cannot be assigned to an unambiguous range value. Whereas constructing a precise depth image based on relative results may still be possible, problems emerge for large or unknown pixel-by-pixel separations or in applications with a wide range of possible scene distances. We introduce a technique to avoid range ambiguity effects in time-of-flight depth imaging systems at high average pulse rates. A long pseudo-random bitstream is used to trigger the illuminating laser. A cyclic, fast-Fourier supported analysis algorithm is used to search for the pattern within return photon events. We demonstrate this approach at base clock rates of up to 2 GHz with varying pattern lengths, allowing for unambiguous distances of several kilometers. Scans at long stand-off distances and of scenes with large pixel-to-pixel range differences are presented. Numerical simulations are performed to investigate the relative merits of the technique.
Perfect count: a novel approach for the single platform enumeration of absolute CD4+ T-lymphocytes.
Storie, Ian; Sawle, Alex; Goodfellow, Karen; Whitby, Liam; Granger, Vivian; Ward, Rosalie Y; Peel, Janet; Smart, Theresa; Reilly, John T; Barnett, David
2004-01-01
The derivation of reliable CD4(+) T lymphocyte counts is vital for the monitoring of disease progression and therapeutic effectiveness in HIV(+) individuals. Flow cytometry has emerged as the method of choice for CD4(+) T lymphocyte enumeration, with single-platform technology, coupled with reference counting beads, fast becoming the "gold standard." However, although single-platform, bead-based, sample acquisition requires the ratio of beads to cells to remain unchanged, there is no available method, until recently, to monitor this. Perfect Count beads have been developed to address this issue and to incorporate two bead populations, with different densities, to allow the detection of inadequate mixing. Comparison of the relative proportions of both beads with the manufacture's defined limits enables an internal QC check during sample acquisition. In this study, we have compared CD4(+) T lymphocyte counts, obtained from 104 HIV(+) patients, using TruCount beads with MultiSet software (defined as the predicated method) and the new Perfect Count beads, incorporating an in house sequential gating strategy. We have demonstrated an excellent degree of correlation between the predicate method and the Perfect Count system (r(2) = 0.9955; Bland Altman bias +27 CD4(+) T lymphocytes/microl). The Perfect Count system is a robust method for performing single platform absolute counts and has the added advantage of having internal QC checks. Such an approach enables the operator to identify potential problems during sample preparation, acquisition and analysis. Copyright 2003 Wiley-Liss, Inc.
A Calibration of NICMOS Camera 2 for Low Count Rates
NASA Astrophysics Data System (ADS)
Rubin, D.; Aldering, G.; Amanullah, R.; Barbary, K.; Dawson, K. S.; Deustua, S.; Faccioli, L.; Fadeyev, V.; Fakhouri, H. K.; Fruchter, A. S.; Gladders, M. D.; de Jong, R. S.; Koekemoer, A.; Krechmer, E.; Lidman, C.; Meyers, J.; Nordin, J.; Perlmutter, S.; Ripoche, P.; Schlegel, D. J.; Spadafora, A.; Suzuki, N.
2015-05-01
NICMOS 2 observations are crucial for constraining distances to most of the existing sample of z\\gt 1 SNe Ia. Unlike conventional calibration programs, these observations involve long exposure times and low count rates. Reciprocity failure is known to exist in HgCdTe devices and a correction for this effect has already been implemented for high and medium count rates. However, observations at faint count rates rely on extrapolations. Here instead, we provide a new zero-point calibration directly applicable to faint sources. This is obtained via inter-calibration of NIC2 F110W/F160W with the Wide Field Camera 3 (WFC3) in the low count-rate regime using z∼ 1 elliptical galaxies as tertiary calibrators. These objects have relatively simple near-IR spectral energy distributions, uniform colors, and their extended nature gives a superior signal-to-noise ratio at the same count rate than would stars. The use of extended objects also allows greater tolerances on point-spread function profiles. We find space telescope magnitude zero points (after the installation of the NICMOS cooling system, NCS) of 25.296\\+/- 0.022 for F110W and 25.803\\+/- 0.023 for F160W, both in agreement with the calibration extrapolated from count rates ≳1000 times larger (25.262 and 25.799). Before the installation of the NCS, we find 24.843\\+/- 0.025 for F110W and 25.498\\+/- 0.021 for F160W, also in agreement with the high-count-rate calibration (24.815 and 25.470). We also check the standard bandpasses of WFC3 and NICMOS 2 using a range of stars and galaxies at different colors and find mild tension for WFC3, limiting the accuracy of the zero points. To avoid human bias, our cross-calibration was “blinded” in that the fitted zero-point differences were hidden until the analysis was finalized. Based on observations with the NASA/ESA Hubble Space Telescope, obtained at the Space Telescope Science Institute, which is operated by AURA, Inc., under NASA contract NAS 5-26555, under programs SM2/NIC-7049, SM2/NIC-7152, CAL/NIC-7607, CAL/NIC-7691, CAL/NIC-7693, GO-7887, CAL/NIC-7902, CAL/NIC-7904, GO/DD-7941, SM3/NIC-8983, SM3/NIC-8986, GTO/ACS-9290, ENG/NIC-9324, CAL/NIC-9325, GO-9352, GO-9375, SNAP-9485, CAL/NIC-9639, GO-9717, GO-9834, GO-9856, CAL/NIC-9995, CAL/NIC-9997, GO-10189, GO-10258, CAL/NIC-10381, CAL/NIC-10454, GO-10496, CAL/NIC-10725, CAL/NIC-10726, GO-10886, CAL/NIC-11060, CAL/NIC-11061, GO-11135, GO-11143, GO-11202, CAL/NIC-11319, GO/DD-11359, SM4/WFC3-11439, SM4/WFC3-11451, GO-11557, GO-11591, GO-11600, GO/DD-11799, CAL/WFC3-11921, CAL/WFC3-11926, GO/DD-12051, GO-12061, GO-12062, GO-12177, CAL/WFC3-12333, CAL/WFC3-12334, CAL/WFC3-12341, GO-12443, GO-12444, GO-12445, CAL/WFC3-12698, CAL/WFC3-12699, GO-12874, CAL/WFC3-13088, and CAL/WFC3-13089.
Structured pedigree information for distributed fusion systems
NASA Astrophysics Data System (ADS)
Arambel, Pablo O.
2008-04-01
One of the most critical challenges in distributed data fusion is the avoidance of information double counting (also called "data incest" or "rumor propagation"). This occurs when a node in a network incorporates information into an estimate - e.g. the position of an object - and the estimate is injected into the network. Other nodes fuse this estimate with their own estimates, and continue to propagate estimates through the network. When the first node receives a fused estimate from the network, it does not know if it already contains its own contributions or not. Since the correlation between its own estimate and the estimate received from the network is not known, the node can not fuse the estimates in an optimal way. If it assumes that both estimates are independent from each other, it unknowingly double counts the information that has already being used to obtain the two estimates. This leads to overoptimistic error covariance matrices. If the double-counting is not kept under control, it may lead to serious performance degradation. Double counting can be avoided by propagating uniquely tagged raw measurements; however, that forces each node to process all the measurements and precludes the propagation of derived information. Another approach is to fuse the information using the Covariance Intersection (CI) equations, which maintain consistent estimates irrespective of the cross-correlation among estimates. However, CI does not exploit pedigree information of any kind. In this paper we present an approach that propagates multiple covariance matrices, one for each uncorrelated source in the network. This is a way to compress the pedigree information and avoids the need to propagate raw measurements. The approach uses a generalized version of the Split CI to fuse different estimates with appropriate weights to guarantee the consistency of the estimates.
Gill, C O; McGinnis, J C; Bryant, J
1998-07-21
The microbiological effects on the product of the series of operations for skinning the hindquarters of beef carcasses at three packing plants were assessed. Samples were obtained at each plant from randomly selected carcasses, by swabbing specified sites related to opening cuts, rump skinning or flank skinning operations, randomly selected sites along the lines of the opening cuts, or randomly selected sites on the skinned hindquarters of carcasses. A set of 25 samples of each type was collected at each plant, with the collection of a single sample from each selected carcass. Aerobic counts, coliforms and Escherichia coli were enumerated in each sample, and a log mean value was estimated for each set of 25 counts on the assumption of a log normal distribution of the counts. The data indicated that the hindquarters skinning operations at plant A were hygienically inferior to those at the other two plants, with mean numbers of coliforms and E. coli being about two orders of magnitude greater, and aerobic counts being an order of magnitude greater on the skinned hindquarters of carcasses from plant A than on those from plants B or C. The data further indicated that the operation for cutting open the skin at plant C was hygienically superior to the equivalent operation at plant B, but that the operations for skinning the rump and flank at plant B were hygienically superior to the equivalent operations at plant C. The findings suggest that objective assessment of the microbiological effects on carcasses of beef carcass dressing processes will be required to ensure that Hazard Analysis: Critical Control Point and Quality Management Systems are operated to control the microbiological condition of carcasses.
Hematological Alterations on Sub-acute Exposure to Flubendiamide in Sprague Dawley Rats.
Vemu, Bhaskar; Dumka, Vinod Kumar
2014-01-01
Pesticide poisoning is a common occurrence around the world. Pesticides can act on various body systems resulting in toxicity. Flubendiamide is a new generation pesticide, reported to have better activity against Lepidopteran insects. The present study was carried out with an objective to analyze the effects of flubendiamide sub-acute exposure on hematology of rats. Male and female Sprague Dawley (SD) rats (9-11 weeks) were divided into five groups with six animals in each group. First group served as control, while the rest were exposed to ascending oral doses of flubendiamide (125, 250, 500 and 1000 mg/kg) for 28 days. After the trial period, blood was collected in heparinized vials and analyzed using Siemens ADVIA 2120(®) autoanalyzer. Various erythrocytic, platelet and leukocyte parameters were measured and analyzed using statistical tests by one-way analysis of variance (ANOVA) and t-test using Statistical Package for Social Sciences (SPSS)(®) 20 software. After processing the data through statistical analysis, it was observed that the effect of flubendiamide exposure on female rats was negligible. The only significant change observed in the female rats was that in total erythrocytic count, while rest of the parameters showed non-significant bidirectional changes. In males, many parameters viz., total leukocyte count (TLC), total erythrocyte count (TEC), packed cell volume (PCV), mean corpuscular volume (MCV), platelet count (PC), mean platelet volume (MPV), platelet distribution width (PDW), hemoglobin distribution width (HDW), large platelets (LPT) and plateletcrit (PCT) expressed significant difference when compared to control. Many of the changes were dose independent, but sex specific. This lead to the hypothesis that saturation toxicokinetics might be one of the reasons for this varied response, which can only be evaluated after further testing.
Shafiee, Mojtaba; Tayefi, Maryam; Hassanian, Seyed Mahdi; Ghaneifar, Zahra; Parizadeh, Mohammad Reza; Avan, Amir; Rahmani, Farzad; Khorasanchi, Zahra; Azarpajouh, Mahmoud Reza; Safarian, Hamideh; Moohebati, Mohsen; Heidari-Bakavoli, Alireza; Esmaeili, Habibolah; Nematy, Mohsen; Safarian, Mohammad; Ebrahimi, Mahmoud; Ferns, Gordon A; Mokhber, Naghmeh; Ghayour-Mobarhan, Majid
2017-10-01
Depression and anxiety are two common mood disorders that are both linked to systemic inflammation. Increased white blood cell (WBC) count and red cell distribution width (RDW) are associated with negative clinical outcomes in a wide variety of pathological conditions. WBC is a non-specific inflammatory marker and RDW is also strongly related to other inflammatory markers. Therefore, we proposed that there might be an association between these hematological inflammatory markers and depression/anxiety symptoms. The primary objective of this study was to examine the association between depression/anxiety symptoms and hematological inflammatory markers including WBC and RDW in a large population-based study. Symptoms of depression and anxiety and a complete blood count (CBC) were measured in 9274 participants (40% males and 60% females) aged 35-65 years, enrolled in a population-based cohort (MASHAD) study in north-eastern Iran. Symptoms of depression and anxiety were evaluated using the Beck Depression and Anxiety Inventories. The mean WBC count increased with increasing severity of symptoms of depression and anxiety among men. Male participants with severe depression had significantly higher values of RDW (p<0.001); however, this relationship was less marked among women (p=0.004). In addition, men (but not women) with severe anxiety symptoms had significantly higher values of RDW (p<0.001). Moreover, there was a negative association between red blood cell (RBC) and mean corpuscular hemoglobin (MCH) and symptoms of depression/anxiety. Our results suggest that higher depression and anxiety scores are associated with an enhanced inflammatory state, as assessed by higher hematological inflammatory markers including WBC and RDW, even after adjusting for potential confounders. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sample to answer visualization pipeline for low-cost point-of-care blood cell counting
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter
2015-03-01
We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.
Arraycount, an algorithm for automatic cell counting in microwell arrays.
Kachouie, Nezamoddin; Kang, Lifeng; Khademhosseini, Ali
2009-09-01
Microscale technologies have emerged as a powerful tool for studying and manipulating biological systems and miniaturizing experiments. However, the lack of software complementing these techniques has made it difficult to apply them for many high-throughput experiments. This work establishes Arraycount, an approach to automatically count cells in microwell arrays. The procedure consists of fluorescent microscope imaging of cells that are seeded in microwells of a microarray system and then analyzing images via computer to recognize the array and count cells inside each microwell. To start counting, green and red fluorescent images (representing live and dead cells, respectively) are extracted from the original image and processed separately. A template-matching algorithm is proposed in which pre-defined well and cell templates are matched against the red and green images to locate microwells and cells. Subsequently, local maxima in the correlation maps are determined and local maxima maps are thresholded. At the end, the software records the cell counts for each detected microwell on the original image in high-throughput. The automated counting was shown to be accurate compared with manual counting, with a difference of approximately 1-2 cells per microwell: based on cell concentration, the absolute difference between manual and automatic counting measurements was 2.5-13%.
VizieR Online Data Catalog: Tidal radii of 7 globular clusters (Lehmann+ 1997)
NASA Astrophysics Data System (ADS)
Lehmann, I.; Scholz, R.-D.
1998-02-01
We present new tidal radii for seven Galactic globular clusters using the method of automated star counts on Schmidt plates of the Tautenburg, Palomar and UK telescopes. The plates were fully scanned with the APM system in Cambridge (UK). Special account was given to a reliable background subtraction and the correction of crowding effects in the central cluster region. For the latter we used a new kind of crowding correction based on a statistical approach to the distribution of stellar images and the luminosity function of the cluster stars in the uncrowded area. The star counts were correlated with surface brightness profiles of different authors to obtain complete projected density profiles of the globular clusters. Fitting an empirical density law (King 1962AJ.....67..471K) we derived the following structural parameters: tidal radius rt, core radius rc and concentration parameter c. In the cases of NGC 5466, M 5, M 12, M 13 and M 15 we found an indication for a tidal tail around these objects (cf. Grillmair et al., 1995AJ....109.2553G). (1 data file).
A heuristic statistical stopping rule for iterative reconstruction in emission tomography.
Ben Bouallègue, F; Crouzet, J F; Mariano-Goulart, D
2013-01-01
We propose a statistical stopping criterion for iterative reconstruction in emission tomography based on a heuristic statistical description of the reconstruction process. The method was assessed for MLEM reconstruction. Based on Monte-Carlo numerical simulations and using a perfectly modeled system matrix, our method was compared with classical iterative reconstruction followed by low-pass filtering in terms of Euclidian distance to the exact object, noise, and resolution. The stopping criterion was then evaluated with realistic PET data of a Hoffman brain phantom produced using the GATE platform for different count levels. The numerical experiments showed that compared with the classical method, our technique yielded significant improvement of the noise-resolution tradeoff for a wide range of counting statistics compatible with routine clinical settings. When working with realistic data, the stopping rule allowed a qualitatively and quantitatively efficient determination of the optimal image. Our method appears to give a reliable estimation of the optimal stopping point for iterative reconstruction. It should thus be of practical interest as it produces images with similar or better quality than classical post-filtered iterative reconstruction with a mastered computation time.
Observational study of Arctium lappa in the treatment of acne vulgaris.
Miglani, Anjali; Manchanda, Raj K
2014-07-01
Arctium lappa (Lappa) is used in traditional Western and Chinese medicine for acne. It is mentioned in homeopathic literature for acne, but its effect has not previously been evaluated. To determine the effectiveness of homeopathic medicine Lappa in treatment of acne vulgaris. An uncontrolled observational interventional study was conducted on human subjects who fulfilled the inclusion criteria and gave written informed consent. Lappa was prescribed in potencies starting from 6c rising to 1M as required, over a period of 6 months. Objective assessment was change in acne lesion counts supplemented with Global Acne Grading System (GAGS) and subjective assessment by using Acne-Specific Quality of Life questionnaire (Acne-QoL). Out of 34 human subjects, 32 completed the follow-up. Statistical significant results were seen in lesion counts, GAGS and Acne-QoL score (p value <0.001). Lappa has shown positive effects in the treatment of acne especially of inflammatory type. Further controlled, randomized studies with larger sample size are desirable. Trial is registered at ClinicalTrials.gov Identifier: NCT01040390. Copyright © 2013 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.
Sleep Estimates Using Microelectromechanical Systems (MEMS)
te Lindert, Bart H. W.; Van Someren, Eus J. W.
2013-01-01
Study Objectives: Although currently more affordable than polysomnography, actigraphic sleep estimates have disadvantages. Brand-specific differences in data reduction impede pooling of data in large-scale cohorts and may not fully exploit movement information. Sleep estimate reliability might improve by advanced analyses of three-axial, linear accelerometry data sampled at a high rate, which is now feasible using microelectromechanical systems (MEMS). However, it might take some time before these analyses become available. To provide ongoing studies with backward compatibility while already switching from actigraphy to MEMS accelerometry, we designed and validated a method to transform accelerometry data into the traditional actigraphic movement counts, thus allowing for the use of validated algorithms to estimate sleep parameters. Design: Simultaneous actigraphy and MEMS-accelerometry recording. Setting: Home, unrestrained. Participants: Fifteen healthy adults (23-36 y, 10 males, 5 females). Interventions: None. Measurements: Actigraphic movement counts/15-sec and 50-Hz digitized MEMS-accelerometry. Analyses: Passing-Bablok regression optimized transformation of MEMS-accelerometry signals to movement counts. Kappa statistics calculated agreement between individual epochs scored as wake or sleep. Bland-Altman plots evaluated reliability of common sleep variables both between and within actigraphs and MEMS-accelerometers. Results: Agreement between epochs was almost perfect at the low, medium, and high threshold (kappa = 0.87 ± 0.05, 0.85 ± 0.06, and 0.83 ± 0.07). Sleep parameter agreement was better between two MEMS-accelerometers or a MEMS-accelerometer and an actigraph than between two actigraphs. Conclusions: The algorithm allows for continuity of outcome parameters in ongoing actigraphy studies that consider switching to MEMS-accelerometers. Its implementation makes backward compatibility feasible, while collecting raw data that, in time, could provide better sleep estimates and promote cross-study data pooling. Citation: te Lindert BHW; Van Someren EJW. Sleep estimates using microelectromechanical systems (MEMS). SLEEP 2013;36(5):781-789. PMID:23633761
Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.
Roessl, Ewald; Brendel, Bernhard; Engel, Klaus-Jürgen; Schlomka, Jens-Peter; Thran, Axel; Proksa, Roland
2011-09-01
The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energy by using energy-sensitive, photon counting X-ray detectors. In this paper, we investigate the dependence of the sensitivity of K-edge imaging on the atomic number Z of the contrast material, on the object diameter D , on the spectral response of the X-ray detector and on the X-ray tube voltage. We assume a photon-counting detector equipped with six adjustable energy thresholds. Physical effects leading to a degradation of the energy resolution of the detector are taken into account using the concept of a spectral response function R(E,U) for which we assume four different models. As a validation of our analytical considerations and in order to investigate the influence of elliptically shaped phantoms, we provide CT simulations of an anthropomorphic Forbild-Abdomen phantom containing a gold-contrast agent. The dependence on the values of the energy thresholds is taken into account by optimizing the achievable signal-to-noise ratios (SNR) with respect to the threshold values. We find that for a given X-ray spectrum and object size the SNR in the heavy element's basis material image peaks for a certain atomic number Z. The dependence of the SNR in the high- Z basis-material image on the object diameter is the natural, exponential decrease with particularly deteriorating effects in the case where the attenuation from the object itself causes a total signal loss below the K-edge. The influence of the energy-response of the detector is very important. We observed that the optimal SNR values obtained with an ideal detector and with a CdTe pixel detector whose response, showing significant tailing, has been determined at a synchrotron differ by factors of about two to three. The potentially very important impact of scattered X-ray radiation and pulse pile-up occurring at high photon rates on the sensitivity of the technique is qualitatively discussed.
Field Assessment of Enclosed Cab Filtration System Performance Using Particle Counting Measurements
Organiscak, John A.; Cecala, Andrew B.; Noll, James D.
2015-01-01
Enclosed cab filtration systems are typically used on mobile mining equipment to reduce miners’ exposure to airborne dust generated during mining operations. The National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has recently worked with a mining equipment manufacturer to examine a new cab filtration system design for underground industrial minerals equipment. This cab filtration system uses a combination of three particulate filters to reduce equipment operators’ exposure to dust and diesel particulates present in underground industrial mineral mines. NIOSH initially examined this cab filtration system using a two-instrument particle counting method at the equipment company’s manufacturing shop facility to assess several alternative filters. This cab filtration system design was further studied on several pieces of equipment during a two- to seven-month period at two underground limestone mines. The two-instrument particle counting method was used outside the underground mine at the end of the production shifts to regularly test the cabs’ long-term protection factor performance with particulates present in the ambient air. This particle counting method showed that three of the four cabs achieved protection factors greater than 1,000 during the field studies. The fourth cab did not perform at this level because it had a damaged filter in the system. The particle counting measurements of submicron particles present in the ambient air were shown to be a timely and useful quantification method in assessing cab performance during these field studies. PMID:23915268
Image-based red cell counting for wild animals blood.
Mauricio, Claudio R M; Schneider, Fabio K; Dos Santos, Leonilda Correia
2010-01-01
An image-based red blood cell (RBC) automatic counting system is presented for wild animals blood analysis. Images with 2048×1536-pixel resolution acquired on an optical microscope using Neubauer chambers are used to evaluate RBC counting for three animal species (Leopardus pardalis, Cebus apella and Nasua nasua) and the error found using the proposed method is similar to that obtained for inter observer visual counting method, i.e., around 10%. Smaller errors (e.g., 3%) can be obtained in regions with less grid artifacts. These promising results allow the use of the proposed method either as a complete automatic counting tool in laboratories for wild animal's blood analysis or as a first counting stage in a semi-automatic counting tool.
Effects of lint cleaning on lint trash particle size distribution
USDA-ARS?s Scientific Manuscript database
Cotton quality trash measurements used today typically yield a single value for trash parameters for a lint sample (i.e. High Volume Instrument – percent area; Advanced Fiber Information System – total count, trash size, dust count, trash count, and visible foreign matter). A Cotton Trash Identifica...
A system for counting fetal and maternal red blood cells.
Ge, Ji; Gong, Zheng; Chen, Jun; Liu, Jun; Nguyen, John; Yang, Zongyi; Wang, Chen; Sun, Yu
2014-12-01
The Kleihauer-Betke (KB) test is the standard method for quantitating fetal-maternal hemorrhage in maternal care. In hospitals, the KB test is performed by a certified technologist to count a minimum of 2000 fetal and maternal red blood cells (RBCs) on a blood smear. Manual counting suffers from inherent inconsistency and unreliability. This paper describes a system for automated counting and distinguishing fetal and maternal RBCs on clinical KB slides. A custom-adapted hardware platform is used for KB slide scanning and image capturing. Spatial-color pixel classification with spectral clustering is proposed to separate overlapping cells. Optimal clustering number and total cell number are obtained through maximizing cluster validity index. To accurately identify fetal RBCs from maternal RBCs, multiple features including cell size, roundness, gradient, and saturation difference between cell and whole slide are used in supervised learning to generate feature vectors, to tackle cell color, shape, and contrast variations across clinical KB slides. The results show that the automated system is capable of completing the counting of over 60,000 cells (versus ∼2000 by technologists) within 5 min (versus ∼15 min by technologists). The throughput is improved by approximately 90 times compared to manual reading by technologists. The counting results are highly accurate and correlate strongly with those from benchmarking flow cytometry measurement.
Routine sampling and the control of Legionella spp. in cooling tower water systems.
Bentham, R H
2000-10-01
Cooling water samples from 31 cooling tower systems were cultured for Legionella over a 16-week summer period. The selected systems were known to be colonized by Legionella. Mean Legionella counts and standard deviations were calculated and time series correlograms prepared for each system. The standard deviations of Legionella counts in all the systems were very large, indicating great variability in the systems over the time period. Time series analyses demonstrated that in the majority of cases there was no significant relationship between the Legionella counts in the cooling tower at time of collection and the culture result once it was available. In the majority of systems (25/28), culture results from Legionella samples taken from the same systems 2 weeks apart were not statistically related. The data suggest that determinations of health risks from cooling towers cannot be reliably based upon single or infrequent Legionella tests.
The association of trail use with weather-related factors on an urban greenway.
Burchfield, Ryan A; Fitzhugh, Eugene C; Bassett, David R
2012-02-01
To study the association between weather-related measures and objectively measured trail use across 3 seasons. Weather has been reported as a barrier to outdoor physical activity (PA), but previous studies have explained only a small amount of the variance in PA using weather-related measures. The dependent variable of this study was trail use measured as mean hourly trail counts by an infrared trail counter located on a greenway. Each trail count represents 1 person breaking the infrared beam of the trail counter. Two sources of weather-related measures were obtained by a site-specific weather station and a public domain weather source. Temperature, relative humidity, and precipitation were significantly correlated with trail counts recorded during daylight hours. More precise hourly weather-related measures explained 42% of the variance in trail counts, regardless of the weather data source with temperature alone explaining 18% of the variance in trail counts. After controlling for all seasonal and weekly factors, every 1°F increase in temperature was associated with an increase of 1.1 trail counts/hr up to 76°F, at which point trail use began to slightly decrease. Weather-related factors have a moderate association with trail use along an urban greenway.
Salciccia, A; Sandersen, C; Grulke, S; de la Rebière de Pouyade, G; Caudron, I; Serteyn, D; Detilleux, J
2013-09-21
The objectives of this study were to describe and relate perioperative changes in blood leukocyte counts to the outcome of surgical colic horses, determine a cut-off value in the early postoperative period to obtain an indicator of the outcome, and compare the obtained value to a validation population of horses. Fifty-three horses undergoing colic surgery were included in the descriptive part of the study. Total leukocyte counts were performed before, during and serially after surgery. A receiver operating characteristic analysis was performed on the leukocyte counts of 45 of these horses to determine a cut-off value for the outcome. The results obtained were validated on a second set of 50 horses that underwent colic surgery in similar conditions. The kinetics of blood leukocytes in survivors was higher than in non-survivors during the first days. Non-survivor horses were more likely to have at least one blood leukocyte count ≤ 3.9 × 10(3)/mm(3) between 28 and 60 hours after surgery than survivor horses. This cut-off value was confirmed in the validation population. These results suggest that routine values of blood leukocyte counts can be used as an additional prognostic indicator after colic surgery alongside other predictors previously associated with the outcome.
Dog ownership and physical activity in later life: a cross-sectional observational study.
Feng, Zhiqiang; Dibben, Chris; Witham, Miles D; Donnan, Peter T; Vadiveloo, Thenmalar; Sniehotta, Falko; Crombie, Iain K; McMurdo, Marion E T
2014-09-01
To examine whether dog ownership amongst community dwelling older adults (≥ 65 years) is associated with objectively measured physical activity (PA). We used data from the Physical Activity Cohort Scotland (PACS) which consists of 547 people aged 65 and over, resident in the community in Tayside, Scotland. The data was collected in 2009-2011. We assessed whether dog ownership is associated with objectively measured physical activity (accelerometry counts). The physical activity (PA) counts of 547 older people (mean age 79 (standard deviation (SD) 8 years, 54% female) were analysed. Linear mixed models showed that dog ownership was positively related to higher PA levels. This positive relationship remained after controlling for a large number of individual and contextual variables, including attitude towards exercise, physical activity intention and history of physical activity. Dog owners were found to be 12% more active (21,875 counts, 95% Confidence Interval (CI): 2810 to 40,939, p<0.05) than non-dog owners. Dog ownership is associated with physical activity in later life. Interventions to increase activity amongst older people might usefully attempt to replicate elements of the dog ownership experience. Copyright © 2014. Published by Elsevier Inc.
Parenting styles, parenting practices, and physical activity in 10- to 11-year olds
Jago, Russell; Davison, Kirsten K.; Brockman, Rowan; Page, Angie S.; Thompson, Janice L.; Fox, Kenneth R.
2011-01-01
Objective The objective of this study was to determine whether parenting styles and practices are associated with children's physical activity. Methods Cross-sectional survey of seven hundred ninety-two 10- to 11-year-old UK children in Bristol (UK) in 2008–2009 was conducted. Accelerometer-assessed physical activity and mean minutes of moderate-to-vigorous physical activity (mean MVPA) and mean counts per minute (mean CPM) were obtained. Maternal parenting style and physical activity parenting practices were self-reported. Results In regression analyses, permissive parenting was associated with higher mean MVPA among girls (+ 6.0 min/day, p < 0.001) and greater mean CPM (+ 98.9 accelerometer counts/min, p = 0.014) among boys when compared to children with authoritative parents. Maternal logistic support was associated with mean CPM for girls (+ 36.2 counts/min, p = 0.001), while paternal logistic support was associated with boys' mean MVPA (+ 4.0 min/day, p = 0.049) and mean CPM (+ 55.7 counts/min, p = 0.014). Conclusions Maternal permissive parenting was associated with higher levels of physical activity than authoritative parenting, but associations differed by child gender and type of physical activity. Maternal logistic support was associated with girls' physical activity, while paternal logistic support was associated with boys' physical activity. Health professionals could encourage parents to increase logistic support for their children's physical activity. PMID:21070805
NASA Astrophysics Data System (ADS)
Weber, M. E.; Reichelt, L.; Kuhn, G.; Thurow, J. W.; Ricken, W.
2009-12-01
We present software-based tools for rapid and quantitative detection of sediment lamination. The BMPix tool extracts color and gray-scale curves from images at ultrahigh (pixel) resolution. The PEAK tool uses the gray-scale curve and performs, for the first time, fully automated counting of laminae based on three methods. The maximum count algorithm counts every bright peak of a couplet of two laminae (annual resolution) in a Gaussian smoothed gray-scale curve. The zero-crossing algorithm counts every positive and negative halfway-passage of the gray-scale curve through a wide moving average. Hence, the record is separated into bright and dark intervals (seasonal resolution). The same is true for the frequency truncation method, which uses Fourier transformation to decompose the gray-scale curve into its frequency components, before positive and negative passages are count. We applied the new methods successfully to tree rings and to well-dated and already manually counted marine varves from Saanich Inlet before we adopted the tools to rather complex marine laminae from the Antarctic continental margin. In combination with AMS14C dating, we found convincing evidence that the laminations from three Weddell Sea sites represent true varves that were deposited on sediment ridges over several millennia during the last glacial maximum (LGM). There are apparently two seasonal layers of terrigenous composition, a coarser-grained bright layer, and a finer-grained dark layer. The new tools offer several advantages over previous tools. The counting procedures are based on a moving average generated from gray-scale curves instead of manual counting. Hence, results are highly objective and rely on reproducible mathematical criteria. Since PEAK associates counts with a specific depth, the thickness of each year or each season is also measured which is an important prerequisite for later spectral analysis. Since all information required to conduct the analysis is displayed graphically, interactive optimization of the counting algorithms can be achieved quickly and conveniently.
Ultrafast photon counting applied to resonant scanning STED microscopy.
Wu, Xundong; Toro, Ligia; Stefani, Enrico; Wu, Yong
2015-01-01
To take full advantage of fast resonant scanning in super-resolution stimulated emission depletion (STED) microscopy, we have developed an ultrafast photon counting system based on a multigiga sample per second analogue-to-digital conversion chip that delivers an unprecedented 450 MHz pixel clock (2.2 ns pixel dwell time in each scan). The system achieves a large field of view (∼50 × 50 μm) with fast scanning that reduces photobleaching, and advances the time-gated continuous wave STED technology to the usage of resonant scanning with hardware-based time-gating. The assembled system provides superb signal-to-noise ratio and highly linear quantification of light that result in superior image quality. Also, the system design allows great flexibility in processing photon signals to further improve the dynamic range. In conclusion, we have constructed a frontier photon counting image acquisition system with ultrafast readout rate, excellent counting linearity, and with the capacity of realizing resonant-scanning continuous wave STED microscopy with online time-gated detection. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.
Kamiya, Yoshito; Ota, Satoru; Okumiya, Shintaro; Yamashita, Kosuke; Takaki, Akihiro; Ito, Shigeki
2017-01-01
Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-to-mediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ratio is useful for distinguishing LBD from non-LBD, it fluctuates depending on the system performance of the gamma cameras. Therefore, a new, simple quantification method using 123I-MIBG uptake analysis is required for clinical study. The purpose of this study was to develop a new uptake index with a simple protocol to determine 123I-MIBG uptake on planar images. Methods: The 123I-MIBG input function was obtained from the input counts of the pulmonary artery (PA), which were assessed by analyzing the PA time-activity curves. The heart region of interest used for determining the H/M was used for calculating the uptake index, which was obtained by dividing the heart count by the input count. Results: Forty-eight patients underwent 123I-MIBG chest angiography and planar imaging, after clinical feature assessment and tracer injection. The H/M and 123I-MIBG uptake index were calculated and correlated with clinical features. Values for LBD were significantly lower than those for non-LBD in all analyses (P<0.001). The overlapping ranges between non-LBD and LBD were 2.15 to 2.49 in the H/M method, and 1.04 to 1.22% in the uptake index method. The diagnostic accuracy of the uptake index (area under the curve (AUC), 0.98; sensitivity, 96%; specificity, 91%; positive predictive value (PPV), 90%; negative predictive value (NPV), 93%; and accuracy, 92%) was approximately equal to that of the H/M (AUC, 0.95; sensitivity, 93%; specificity, 91%; PPV, 90%; NPV, 93%; and accuracy, 92%) for discriminating patients with LBD and non-LBD. Conclusion: A simple uptake index method was developed using 123I-MIBG planar imaging and the input counts determined by analyzing chest radioisotope angiography images of the PA. The diagnostic accuracy of the uptake index was approximately equal to that of the H/M for discriminating patients with LBD and non-LBD. PMID:28840137
Garment Counting in a Textile Warehouse by Means of a Laser Imaging System
Martínez-Sala, Alejandro Santos; Sánchez-Aartnoutse, Juan Carlos; Egea-López, Esteban
2013-01-01
Textile logistic warehouses are highly automated mechanized places where control points are needed to count and validate the number of garments in each batch. This paper proposes and describes a low cost and small size automated system designed to count the number of garments by processing an image of the corresponding hanger hooks generated using an array of phototransistors sensors and a linear laser beam. The generated image is processed using computer vision techniques to infer the number of garment units. The system has been tested on two logistic warehouses with a mean error in the estimated number of hangers of 0.13%. PMID:23628760
Garment counting in a textile warehouse by means of a laser imaging system.
Martínez-Sala, Alejandro Santos; Sánchez-Aartnoutse, Juan Carlos; Egea-López, Esteban
2013-04-29
Textile logistic warehouses are highly automated mechanized places where control points are needed to count and validate the number of garments in each batch. This paper proposes and describes a low cost and small size automated system designed to count the number of garments by processing an image of the corresponding hanger hooks generated using an array of phototransistors sensors and a linear laser beam. The generated image is processed using computer vision techniques to infer the number of garment units. The system has been tested on two logistic warehouses with a mean error in the estimated number of hangers of 0.13%.
da Costa, Filipe Ferreira; Schmoelz, Camilie Pacheco; Davies, Vanessa Fernandes; Di Pietro, Patrícia Faria; Kupek, Emil; de Assis, Maria Alice Altenburg
2013-08-19
Information and communication technology (ICT) has been used with increasing frequency for the assessment of diet and physical activity in health surveys. A number of Web-based questionnaires have been developed for children and adolescents. However, their usability characteristics have scarcely been reported, despite their potential importance for improving the feasibility and validity of ICT-based methods. The objective of this study was to describe the usability evaluation of the Consumo Alimentar e Atividade Física de Escolares (CAAFE) questionnaire (Food Consumption and Physical Activity Questionnaire for schoolchildren), a new Web-based survey tool for the self-assessment of diet and physical activity by schoolchildren. A total of 114 schoolchildren aged 6 to 12 years took part in questionnaire usability testing carried out in computer classrooms at five elementary schools in the city of Florianopolis, Brazil. Schoolchildren used a personal computer (PC) equipped with software for recording what is on the computer screen and the children's speech during usability testing. Quantitative and qualitative analyses took into account objective usability metrics such as error counts and time to complete a task. Data on the main difficulties in accomplishing the task and the level of satisfaction expressed by the children were assessed by the observers using a standardized form and interviews with the children. Descriptive statistics and content analysis were used to summarize both the quantitative and the qualitative aspects of the data obtained. The mean time for completing the questionnaire was 13.7 minutes (SD 3.68). Compared to the children in 2nd or 3rd grades, those in 4th or 5th grades spent less time completing the questionnaire (median 12.4 vs 13.3 minutes, P=.022), asked for help less frequently (median 0 vs 1.0 count, P=.005), had a lower error count (median 2.0 vs 8.0 count, P<.001), and obtained a higher overall performance score (median 73.0 vs 68.0, P=.005). Children with a PC at home spent less time completing the questionnaire (median 12.3 vs 14.9 minutes, P<.001), had a lower overall error count (median 2.0 vs 9.0 count, P=.03), and had a higher performance score (median 72.0 vs 64.0, P=.005) compared to the children without a PC at home. The most common difficulty in completing the questionnaire was in using the scroll bar. The majority of children reported a positive evaluation (liked a lot or liked) for the four design elements, which were evaluated. The results of the present study provided feedback to improve the final version of the CAAFE questionnaire. Quantitative data showed minor errors and system failures, while qualitative data indicated that, overall, the children enjoyed the CAAFE questionnaire. Grade levels and PC use must be taken into account in Web-based tools designed for children.
A video-based real-time adaptive vehicle-counting system for urban roads.
Liu, Fei; Zeng, Zhiyuan; Jiang, Rong
2017-01-01
In developing nations, many expanding cities are facing challenges that result from the overwhelming numbers of people and vehicles. Collecting real-time, reliable and precise traffic flow information is crucial for urban traffic management. The main purpose of this paper is to develop an adaptive model that can assess the real-time vehicle counts on urban roads using computer vision technologies. This paper proposes an automatic real-time background update algorithm for vehicle detection and an adaptive pattern for vehicle counting based on the virtual loop and detection line methods. In addition, a new robust detection method is introduced to monitor the real-time traffic congestion state of road section. A prototype system has been developed and installed on an urban road for testing. The results show that the system is robust, with a real-time counting accuracy exceeding 99% in most field scenarios.
A video-based real-time adaptive vehicle-counting system for urban roads
2017-01-01
In developing nations, many expanding cities are facing challenges that result from the overwhelming numbers of people and vehicles. Collecting real-time, reliable and precise traffic flow information is crucial for urban traffic management. The main purpose of this paper is to develop an adaptive model that can assess the real-time vehicle counts on urban roads using computer vision technologies. This paper proposes an automatic real-time background update algorithm for vehicle detection and an adaptive pattern for vehicle counting based on the virtual loop and detection line methods. In addition, a new robust detection method is introduced to monitor the real-time traffic congestion state of road section. A prototype system has been developed and installed on an urban road for testing. The results show that the system is robust, with a real-time counting accuracy exceeding 99% in most field scenarios. PMID:29135984
NASA Technical Reports Server (NTRS)
Edmonds, Jessica
2015-01-01
Aurora Flight Sciences, in partnership with Draper Laboratory, has developed a miniaturized system to count white blood cells in microgravity environments. The system uses MEMS technology to simultaneously count total white blood cells, the five white blood cell differential subgroups, and various lymphocyte subtypes. The OILWBCS-MEMS detection technology works by immobilizing an array of white blood cell-specific antibodies on small, gold-coated membranes. When blood flows across the membranes, specific cells' surface protein antigens bind to their corresponding antibodies. This binding can be measured and correlated to cell counts. In Phase I, the partners demonstrated surface chemistry sensitivity and specificity for total white blood cells and two lymphocyte subtypes. In Phase II, a functional prototype demonstrated end-to-end operation. This rugged, miniaturized device requires minimal blood sample preparation and will be useful for both space flight and terrestrial applications.
X-ray fluorescence camera for imaging of iodine media in vivo.
Matsukiyo, Hiroshi; Watanabe, Manabu; Sato, Eiichi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Abderyim, Purkhet; Aizawa, Katsuo; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ehara, Shigeru; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun
2009-01-01
X-ray fluorescence (XRF) analysis is useful for measuring density distributions of contrast media in vivo. An XRF camera was developed for carrying out mapping for iodine-based contrast media used in medical angiography. Objects are exposed by an X-ray beam from a cerium target. Cerium K-series X-rays are absorbed effectively by iodine media in objects, and iodine fluorescence is produced from the objects. Next, iodine Kalpha fluorescence is selected out by use of a 58-microm-thick stannum filter and is detected by a cadmium telluride (CdTe) detector. The Kalpha rays are discriminated out by a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x-y stage in conjunction with a two-stage controller, and X-ray images obtained by iodine mapping are shown on a personal computer monitor. The scan pitch of the x and y axes was 2.5 mm, and the photon counting time per mapping point was 2.0 s. We carried out iodine mapping of non-living animals (phantoms), and iodine Kalpha fluorescence was produced from weakly remaining iodine elements in a rabbit skin cancer.
NASA Astrophysics Data System (ADS)
Weber, M. E.; Reichelt, L.; Kuhn, G.; Pfeiffer, M.; Korff, B.; Thurow, J.; Ricken, W.
2010-03-01
We present tools for rapid and quantitative detection of sediment lamination. The BMPix tool extracts color and gray scale curves from images at pixel resolution. The PEAK tool uses the gray scale curve and performs, for the first time, fully automated counting of laminae based on three methods. The maximum count algorithm counts every bright peak of a couplet of two laminae (annual resolution) in a smoothed curve. The zero-crossing algorithm counts every positive and negative halfway passage of the curve through a wide moving average, separating the record into bright and dark intervals (seasonal resolution). The same is true for the frequency truncation method, which uses Fourier transformation to decompose the curve into its frequency components before counting positive and negative passages. The algorithms are available at doi:10.1594/PANGAEA.729700. We applied the new methods successfully to tree rings, to well-dated and already manually counted marine varves from Saanich Inlet, and to marine laminae from the Antarctic continental margin. In combination with AMS14C dating, we found convincing evidence that laminations in Weddell Sea sites represent varves, deposited continuously over several millennia during the last glacial maximum. The new tools offer several advantages over previous methods. The counting procedures are based on a moving average generated from gray scale curves instead of manual counting. Hence, results are highly objective and rely on reproducible mathematical criteria. Also, the PEAK tool measures the thickness of each year or season. Since all information required is displayed graphically, interactive optimization of the counting algorithms can be achieved quickly and conveniently.
Van Stappen, Vicky; Van Dyck, Delfien; Latomme, Julie; De Bourdeaudhuij, Ilse; Moreno, Luis; Socha, Piotr; Iotova, Violeta; Koletzko, Berthold; Manios, Yannis; Androutsos, Odysseas; Cardon, Greet; De Craemer, Marieke
2018-02-07
This study is part of the ToyBox-study, which is conducted in six European countries (Belgium, Bulgaria, Germany, Greece, Poland and Spain), aiming to develop a cost-effective kindergarten-based, family-involved intervention to prevent overweight and obesity in four- to six-year-old preschool children. In the current study, we aimed to examine and compare preschoolers' step count patterns, across the six European countries. A sample of 3578 preschoolers (mean age: 4.8 ± 0.4) was included. Multilevel analyses were performed to take clustering of measurements into account. Based on the average hourly steps, step count patterns for the six European countries were created for weekdays and weekend days. The step count patterns during weekdays were related to the daily kindergarten schedules. Step count patterns during weekdays showed several significant peaks and troughs ( p < 0.01) and clearly reflected the kindergartens' daily schedules, except for Germany. For example, low numbers of steps were observed during afternoon naptimes and high numbers of steps during recess. In Germany, step count patterns did not show clear peaks and troughs, which can be explained by a less structured kindergarten schedule. On weekend days, differences in step count patterns were observed in the absolute number of steps in the afternoon trough and the period in which the evening peak occurred. Differences in step count patterns across the countries can be explained by differences in (school) policy, lifestyle habits, and culture. Therefore, it might be important to respond to these step count patterns and more specifically to tackle the inactive periods during interventions to promote physical activity in preschoolers.
Factors Associated With Ambulatory Activity in De Novo Parkinson Disease.
Christiansen, Cory; Moore, Charity; Schenkman, Margaret; Kluger, Benzi; Kohrt, Wendy; Delitto, Anthony; Berman, Brian; Hall, Deborah; Josbeno, Deborah; Poon, Cynthia; Robichaud, Julie; Wellington, Toby; Jain, Samay; Comella, Cynthia; Corcos, Daniel; Melanson, Ed
2017-04-01
Objective ambulatory activity during daily living has not been characterized for people with Parkinson disease prior to initiation of dopaminergic medication. Our goal was to characterize ambulatory activity based on average daily step count and examine determinants of step count in nonexercising people with de novo Parkinson disease. We analyzed baseline data from a randomized controlled trial, which excluded people performing regular endurance exercise. Of 128 eligible participants (mean ± SD = 64.3 ± 8.6 years), 113 had complete accelerometer data, which were used to determine daily step count. Multiple linear regression was used to identify factors associated with average daily step count over 10 days. Candidate explanatory variable categories were (1) demographics/anthropometrics, (2) Parkinson disease characteristics, (3) motor symptom severity, (4) nonmotor and behavioral characteristics, (5) comorbidities, and (6) cardiorespiratory fitness. Average daily step count was 5362 ± 2890 steps per day. Five factors explained 24% of daily step count variability, with higher step count associated with higher cardiorespiratory fitness (10%), no fear/worry of falling (5%), lower motor severity examination score (4%), more recent time since Parkinson disease diagnosis (3%), and the presence of a cardiovascular condition (2%). Daily step count in nonexercising people recruited for this intervention trial with de novo Parkinson disease approached sedentary lifestyle levels. Further study is warranted for elucidating factors explaining ambulatory activity, particularly cardiorespiratory fitness, and fear/worry of falling. Clinicians should consider the costs and benefits of exercise and activity behavior interventions immediately after diagnosis of Parkinson disease to attenuate the health consequences of low daily step count.Video Abstract available for more insights from the authors (see Video, Supplemental Digital Content 1, http://links.lww.com/JNPT/A170).
Brudvig, Jean M; Swenson, Cheryl L
2015-12-01
Rapid and precise measurement of total and differential nucleated cell counts is a crucial diagnostic component of cavitary and synovial fluid analyses. The objectives of this study included (1) evaluation of reliability and precision of canine and equine fluid total nucleated cell count (TNCC) determined by the benchtop Abaxis VetScan HM5, in comparison with the automated reference instruments ADVIA 120 and the scil Vet abc, respectively, and (2) comparison of automated with manual canine differential nucleated cell counts. The TNCC and differential counts in canine pleural and peritoneal, and equine synovial fluids were determined on the Abaxis VetScan HM5 and compared with the ADVIA 120 and Vet abc analyzer, respectively. Statistical analyses included correlation, least squares fit linear regression, Passing-Bablok regression, and Bland-Altman difference plots. In addition, precision of the total cell count generated by the VetScan HM5 was determined. Agreement was excellent without significant constant or proportional bias for canine cavitary fluid TNCC. Automated and manual differential counts had R(2) < .5 for individual cell types (least squares fit linear regression). Equine synovial fluid TNCC agreed but with some bias due to the VetScan HM5 overestimating TNCC compared to the Vet abc. Intra-assay precision of the VetScan HM5 in 3 fluid samples was 2-31%. The Abaxis VetScan HM5 provided rapid, reliable TNCC for canine and equine fluid samples. The differential nucleated cell count should be verified microscopically as counts from the VetScan HM5 and also from the ADVIA 120 were often incorrect in canine fluid samples. © 2015 American Society for Veterinary Clinical Pathology.
Van Stappen, Vicky; Latomme, Julie; Moreno, Luis; Socha, Piotr; Iotova, Violeta; Koletzko, Berthold; Manios, Yannis; Androutsos, Odysseas
2018-01-01
This study is part of the ToyBox-study, which is conducted in six European countries (Belgium, Bulgaria, Germany, Greece, Poland and Spain), aiming to develop a cost-effective kindergarten-based, family-involved intervention to prevent overweight and obesity in four- to six-year-old preschool children. In the current study, we aimed to examine and compare preschoolers’ step count patterns, across the six European countries. A sample of 3578 preschoolers (mean age: 4.8 ± 0.4) was included. Multilevel analyses were performed to take clustering of measurements into account. Based on the average hourly steps, step count patterns for the six European countries were created for weekdays and weekend days. The step count patterns during weekdays were related to the daily kindergarten schedules. Step count patterns during weekdays showed several significant peaks and troughs (p < 0.01) and clearly reflected the kindergartens’ daily schedules, except for Germany. For example, low numbers of steps were observed during afternoon naptimes and high numbers of steps during recess. In Germany, step count patterns did not show clear peaks and troughs, which can be explained by a less structured kindergarten schedule. On weekend days, differences in step count patterns were observed in the absolute number of steps in the afternoon trough and the period in which the evening peak occurred. Differences in step count patterns across the countries can be explained by differences in (school) policy, lifestyle habits, and culture. Therefore, it might be important to respond to these step count patterns and more specifically to tackle the inactive periods during interventions to promote physical activity in preschoolers. PMID:29414916
Walker, R.S.; Novare, A.J.; Nichols, J.D.
2000-01-01
Estimation of abundance of mammal populations is essential for monitoring programs and for many ecological investigations. The first step for any study of variation in mammal abundance over space or time is to define the objectives of the study and how and why abundance data are to be used. The data used to estimate abundance are count statistics in the form of counts of animals or their signs. There are two major sources of uncertainty that must be considered in the design of the study: spatial variation and the relationship between abundance and the count statistic. Spatial variation in the distribution of animals or signs may be taken into account with appropriate spatial sampling. Count statistics may be viewed as random variables, with the expected value of the count statistic equal to the true abundance of the population multiplied by a coefficient p. With direct counts, p represents the probability of detection or capture of individuals, and with indirect counts it represents the rate of production of the signs as well as their probability of detection. Comparisons of abundance using count statistics from different times or places assume that the p are the same for all times or places being compared (p= pi). In spite of considerable evidence that this assumption rarely holds true, it is commonly made in studies of mammal abundance, as when the minimum number alive or indices based on sign counts are used to compare abundance in different habitats or times. Alternatives to relying on this assumption are to calibrate the index used by testing the assumption of p= pi, or to incorporate the estimation of p into the study design.
Newell, Felicity L.; Sheehan, James; Wood, Petra Bohall; Rodewald, Amanda D.; Buehler, David A.; Keyser, Patrick D.; Larkin, Jeffrey L.; Beachy, Tiffany A.; Bakermans, Marja H.; Boves, Than J.; Evans, Andrea; George, Gregory A.; McDermott, Molly E.; Perkins, Kelly A.; White, Matthew; Wigley, T. Bently
2013-01-01
Point counts are commonly used to assess changes in bird abundance, including analytical approaches such as distance sampling that estimate density. Point-count methods have come under increasing scrutiny because effects of detection probability and field error are difficult to quantify. For seven forest songbirds, we compared fixed-radii counts (50 m and 100 m) and density estimates obtained from distance sampling to known numbers of birds determined by territory mapping. We applied point-count analytic approaches to a typical forest management question and compared results to those obtained by territory mapping. We used a before–after control impact (BACI) analysis with a data set collected across seven study areas in the central Appalachians from 2006 to 2010. Using a 50-m fixed radius, variance in error was at least 1.5 times that of the other methods, whereas a 100-m fixed radius underestimated actual density by >3 territories per 10 ha for the most abundant species. Distance sampling improved accuracy and precision compared to fixed-radius counts, although estimates were affected by birds counted outside 10-ha units. In the BACI analysis, territory mapping detected an overall treatment effect for five of the seven species, and effects were generally consistent each year. In contrast, all point-count methods failed to detect two treatment effects due to variance and error in annual estimates. Overall, our results highlight the need for adequate sample sizes to reduce variance, and skilled observers to reduce the level of error in point-count data. Ultimately, the advantages and disadvantages of different survey methods should be considered in the context of overall study design and objectives, allowing for trade-offs among effort, accuracy, and power to detect treatment effects.
Bonomi, Alberto G; Westerterp, Klaas R
2016-01-01
Background Physical activity is recommended to promote healthy aging. Defining the importance of activities such as walking in achieving higher levels of physical activity might provide indications for interventions. Objective To describe the importance of walking in achieving higher levels of physical activity in older adults. Methods The study included 42 healthy subjects aged between 51 and 84 years (mean body mass index 25.6 kg/m2 [SD 2.6]). Physical activity, walking, and nonwalking activity were monitored with an accelerometer for 2 weeks. Physical activity was quantified by accelerometer-derived activity counts. An algorithm based on template matching and signal power was developed to classify activity counts into nonwalking counts, short walk counts, and long walk counts. Additionally, in a subgroup of 31 subjects energy expenditure was measured using doubly labeled water to derive physical activity level (PAL). Results Subjects had a mean PAL of 1.84 (SD 0.19, range 1.43-2.36). About 20% of the activity time (21% [SD 8]) was spent walking, which accounted for about 40% of the total counts (43% [SD 11]). Short bouts composed 83% (SD 9) of walking time, providing 81% (SD 11) of walking counts. A stepwise regression model to predict PAL included nonwalking counts and short walk counts, explaining 58% of the variance of PAL (standard error of the estimate=0.12). Walking activities produced more counts per minute than nonwalking activities (P<.001). Long walks produced more counts per minute than short walks (P=.001). Nonwalking counts were independent of walking counts (r=−.05, P=.38). Conclusions Walking activities are a major contributor to physical activity in older adults. Walking activities occur at higher intensities than nonwalking activities, which might prevent individuals from engaging in more walking activity. Finally, subjects who engage in more walking activities do not tend to compensate by limiting nonwalking activities. Trial Registration ClinicalTrials.gov NCT01609764; https://clinicaltrials.gov/ct2/show/NCT01609764 (Archived by WebCite at http://www.webcitation.org/6grls0wAp) PMID:27268471
Study of Compton suppression for use in spent nuclear fuel assay
NASA Astrophysics Data System (ADS)
Bender, Sarah
The focus of this study has been to assess Compton suppressed gamma-ray detection systems for the multivariate analysis of spent nuclear fuel. This objective has been achieved using direct measurement of samples of irradiated fuel elements in two geometrical configurations with Compton suppression systems. In order to address the objective to quantify the number of additionally resolvable photopeaks, direct Compton suppressed spectroscopic measurements of spent nuclear fuel in two configurations were performed: as intact fuel elements and as dissolved feed solutions. These measurements directly assessed and quantified the differences in measured gamma-ray spectrum from the application of Compton suppression. Several irradiated fuel elements of varying cooling time from the Penn State Breazeale Reactor spent fuel inventory were measured using three Compton suppression systems that utilized different primary detectors: HPGe, LaBr3, and NaI(Tl). The application of Compton suppression using a LaBr3 primary detector to the measurement of the current core fuel element, which presented the highest count rate, allowed four additional spectral features to be resolved. In comparison, the HPGe-CSS was able to resolve eight additional photopeaks as compared to the standalone HPGe measurement. Measurements with the NaI(Tl) primary detector were unable to resolve any additional peaks, due to its relatively low resolution. Samples of Approved Test Material (ATM) commercial fuel elements were obtained from Pacific Northwest National Laboratory. The samples had been processed using the beginning stages of the PUREX method and represented the unseparated feed solution from a reprocessing facility. Compton suppressed measurements of the ATM fuel samples were recorded inside the guard detector annulus, to simulate the siphoning of small quantities from the main process stream for long dwell measurement periods. Photopeak losses were observed in the measurements of the dissolved ATM fuel samples because the spectra was recorded from the source in very close proximity to the detector and surrounded by the guard annulus, so the detection probability is very high. Though this configuration is optimal for a Compton suppression system for the measurement of low count rate samples, measurement of high count rate samples in the enclosed arrangement leads to sum peaks in both the suppressed and unsuppressed spectra and losses to photopeak counts in the suppressed spectra. No additional photopeaks were detected using Compton suppression with this geometry. A detector model was constructed that can accurately simulate a Compton suppressed spectral measurement of radiation from spent nuclear fuel using HPGe or LaBr3 detectors. This is the first detector model capable of such an accomplishment. The model uses the Geant4 toolkit coupled with the RadSrc application and it accepts spent fuel composition data in list form. The model has been validated using dissolved ATM fuel samples in the standard, enclosed geometry of the PSU HPGe-CSS. The model showed generally good agreement with both the unsuppressed and suppressed measured fuel sample spectra, however the simulation is more appropriate for the generation of gamma-ray spectra in the beam source configuration. Photopeak losses due to cascade decay emissions in the Compton suppressed spectra were not appropriately managed by the simulation. Compton suppression would be a beneficial addition to NDA process monitoring systems if oriented such that the gamma-ray photons are collimated to impinge the primary detector face as a beam. The analysis has shown that peak losses through accidental coincidences are minimal and the reduction in the Compton continuum allows additional peaks to be resolved. (Abstract shortened by UMI.).
Photon Counting System for High-Sensitivity Detection of Bioluminescence at Optical Fiber End.
Iinuma, Masataka; Kadoya, Yutaka; Kuroda, Akio
2016-01-01
The technique of photon counting is widely used for various fields and also applicable to a high-sensitivity detection of luminescence. Thanks to recent development of single photon detectors with avalanche photodiodes (APDs), the photon counting system with an optical fiber has become powerful for a detection of bioluminescence at an optical fiber end, because it allows us to fully use the merits of compactness, simple operation, highly quantum efficiency of the APD detectors. This optical fiber-based system also has a possibility of improving the sensitivity to a local detection of Adenosine triphosphate (ATP) by high-sensitivity detection of the bioluminescence. In this chapter, we are introducing a basic concept of the optical fiber-based system and explaining how to construct and use this system.
Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme
NASA Technical Reports Server (NTRS)
Van Amerom, Friso H.; Short, Tim; Brinckerhoff, William; Mahaffy, Paul; Kleyner, Igor; Cotter, Robert J.; Pinnick, Veronica; Hoffman, Lars; Danell, Ryan M.; Lyness, Eric I.
2011-01-01
The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250
System concepts and enabling technologies for an ESA low-cost mission to Jupiter / Europa
NASA Astrophysics Data System (ADS)
Renard, P.; Koeck, C.; Kemble, Steve; Atzei, Alessandro; Falkner, Peter
2004-11-01
The European Space Agency is currently studying the Jovian Minisat Explorer (JME), as part of its Technology Reference Studies (TRS), used for its development plan of technologies enabling future scientific missions. The JME focuses on the exploration of the Jovian system and particularly of Europa. The Jupiter Minisat Orbiter (JMO) study concerns the first mission phase of JME that counts up to three missions using pairs of minisats. The scientific objectives are the investigation of Europa's global topography, the composition of its (sub)surface and the demonstration of existence of a subsurface ocean below its icy crust. The present paper describes the candidate JMO system concept, based on a Europa Orbiter (JEO) supported by a communications relay satellite (JRS), and its associated technology development plan. It summarizes an analysis performed in 2004 jointly by ESA and the EADS-Astrium Company in the frame of an industrial technical assistance to ESA.
NASA Astrophysics Data System (ADS)
Yin, Guoyan; Zhang, Limin; Zhang, Yanqi; Liu, Han; Du, Wenwen; Ma, Wenjuan; Zhao, Huijuan; Gao, Feng
2018-02-01
Pharmacokinetic diffuse fluorescence tomography (DFT) can describe the metabolic processes of fluorescent agents in biomedical tissue and provide helpful information for tumor differentiation. In this paper, a dynamic DFT system was developed by employing digital lock-in-photon-counting with square wave modulation, which predominates in ultra-high sensitivity and measurement parallelism. In this system, 16 frequency-encoded laser diodes (LDs) driven by self-designed light source system were distributed evenly in the imaging plane and irradiated simultaneously. Meanwhile, 16 detection fibers collected emission light in parallel by the digital lock-in-photon-counting module. The fundamental performances of the proposed system were assessed with phantom experiments in terms of stability, linearity, anti-crosstalk as well as images reconstruction. The results validated the availability of the proposed dynamic DFT system.
Three-camera stereo vision for intelligent transportation systems
NASA Astrophysics Data System (ADS)
Bergendahl, Jason; Masaki, Ichiro; Horn, Berthold K. P.
1997-02-01
A major obstacle in the application of stereo vision to intelligent transportation system is high computational cost. In this paper, a PC based three-camera stereo vision system constructed with off-the-shelf components is described. The system serves as a tool for developing and testing robust algorithms which approach real-time performance. We present an edge based, subpixel stereo algorithm which is adapted to permit accurate distance measurements to objects in the field of view using a compact camera assembly. Once computed, the 3D scene information may be directly applied to a number of in-vehicle applications, such as adaptive cruise control, obstacle detection, and lane tracking. Moreover, since the largest computational costs is incurred in generating the 3D scene information, multiple applications that leverage this information can be implemented in a single system with minimal cost. On-road applications, such as vehicle counting and incident detection, are also possible. Preliminary in-vehicle road trial results are presented.
Schreiter, V; Steffen, I; Huebner, H; Bredow, J; Heimann, U; Kroencke, T J; Poellinger, A; Doellinger, F; Buchert, R; Hamm, B; Brenner, W; Schreiter, N F
2015-01-01
The purpose of this study was to evaluate the reproducibility of a new software based analysing system for ventilation/perfusion single-photon emission computed tomography/computed tomography (V/P SPECT/CT) in patients with pulmonary emphysema and to compare it to the visual interpretation. 19 patients (mean age: 68.1 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. Data were analysed by two independent observers in visual interpretation (VI) and by software based analysis system (SBAS). SBAS PMOD version 3.4 (Technologies Ltd, Zurich, Switzerland) was used to assess counts and volume per lung lobe/per lung and to calculate the count density per lung, lobe ratio of counts and ratio of count density. VI was performed using a visual scale to assess the mean counts per lung lobe. Interobserver variability and association for SBAS and VI were analysed using Spearman's rho correlation coefficient. Interobserver agreement correlated highly in perfusion (rho: 0.982, 0.957, 0.90, 0.979) and ventilation (rho: 0.972, 0.924, 0.941, 0.936) for count/count density per lobe and ratio of counts/count density in SBAS. Interobserver agreement correlated clearly for perfusion (rho: 0.655) and weakly for ventilation (rho: 0.458) in VI. SBAS provides more reproducible measures than VI for the relative tracer uptake in V/P SPECT/CTs in patients with pulmonary emphysema. However, SBAS has to be improved for routine clinical use.
On the frequency response of a Wenglor particle-counting system for aeolian transport measurements
NASA Astrophysics Data System (ADS)
Bauer, Bernard O.; Davidson-Arnott, Robin G. D.; Hilton, Michael J.; Fraser, Douglas
2018-06-01
A commonly deployed particle-counting system for aeolian saltation flux, consisting of a Wenglor fork sensor and an Onset Hobo Pulse Input Adapter linked to an Onset Hobo Energy Logger Pro data logger, was tested for frequency response. The Wenglor fork sensor is an optical gate device that has very fast switching capacity that can accommodate the time of flight of saltating sand particles through the sensing volume with the exception of very fine sand or silt and very quickly moving particles. The Pulse Input Adapter, in contrast, imposes limitations on the frequency response of the system. The manufacturer of the pulse adapter specifies an upper limit of 120 Hz, although bench tests with an electronic pulse generator indicate that the frequency response of the Pulse Input Adapter, in isolation, is excellent up to 3000 Hz, with only small error (less than 1.6%) due to under-counting during data transfer intervals. A mechanical test of the integrated system (fork sensor, pulse input adapter, and data logger) demonstrates excellent performance up to about 700 Hz (less than 2% error), but significant under-counting above 1000 Hz for unknown reasons. This specific particle-counting system therefore has a frequency response that is well suited for investigation of the dynamics of aeolian saltation as typically encountered in most field conditions on coastal beaches with the exception of extreme wind events and very small particle sizes.
NASA Astrophysics Data System (ADS)
Wilson, Jolaine M.; Krigsfeld, Gabriel S.; Sanzari, Jenine K.; Wagner, Erika B.; Mick, Rosemarie; Kennedy, Ann R.
2012-01-01
Animal models are frequently used to assist in the determination of the long- and short-term effects of space flight. The space environment, including microgravity, can impact many physiological and immunological system parameters. It has been found that ground based models of microgravity produce changes in white blood cell counts, which negatively affects immunologic function. As part of the Center of Acute Radiation Research (CARR), we compared the acute effects on white blood cell parameters induced by the more traditionally used animal model of hindlimb unloading (HU) with a recently developed reduced weightbearing analog known as partial weight suspension (PWS). Female ICR mice were either hindlimb unloaded or placed in the PWS system at 16% quadrupedal weightbearing for 4 h, 1, 2, 7 or 10 days, at which point complete blood counts were obtained. Control animals (jacketed and non-jacketed) were exposed to identical conditions without reduced weightbearing. Results indicate that significant changes in total white blood cell (WBC), neutrophil, lymphocyte, monocyte and eosinophil counts were observed within the first 2 days of exposure to each system. These differences in blood cell counts normalized by day 7 in both systems. The results of these studies indicate that there are some statistically significant changes observed in the blood cell counts for animals exposed to both the PWS and HU simulated microgravity systems.
Hyper-Fractal Analysis: A visual tool for estimating the fractal dimension of 4D objects
NASA Astrophysics Data System (ADS)
Grossu, I. V.; Grossu, I.; Felea, D.; Besliu, C.; Jipa, Al.; Esanu, T.; Bordeianu, C. C.; Stan, E.
2013-04-01
This work presents a new version of a Visual Basic 6.0 application for estimating the fractal dimension of images and 3D objects (Grossu et al. (2010) [1]). The program was extended for working with four-dimensional objects stored in comma separated values files. This might be of interest in biomedicine, for analyzing the evolution in time of three-dimensional images. New version program summaryProgram title: Hyper-Fractal Analysis (Fractal Analysis v03) Catalogue identifier: AEEG_v3_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEG_v3_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Standard CPC license, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 745761 No. of bytes in distributed program, including test data, etc.: 12544491 Distribution format: tar.gz Programming language: MS Visual Basic 6.0 Computer: PC Operating system: MS Windows 98 or later RAM: 100M Classification: 14 Catalogue identifier of previous version: AEEG_v2_0 Journal reference of previous version: Comput. Phys. Comm. 181 (2010) 831-832 Does the new version supersede the previous version? Yes Nature of problem: Estimating the fractal dimension of 4D images. Solution method: Optimized implementation of the 4D box-counting algorithm. Reasons for new version: Inspired by existing applications of 3D fractals in biomedicine [3], we extended the optimized version of the box-counting algorithm [1, 2] to the four-dimensional case. This might be of interest in analyzing the evolution in time of 3D images. The box-counting algorithm was extended in order to support 4D objects, stored in comma separated values files. A new form was added for generating 2D, 3D, and 4D test data. The application was tested on 4D objects with known dimension, e.g. the Sierpinski hypertetrahedron gasket, Df=ln(5)/ln(2) (Fig. 1). The algorithm could be extended, with minimum effort, to higher number of dimensions. Easy integration with other applications by using the very simple comma separated values file format for storing multi-dimensional images. Implementation of χ2 test as a criterion for deciding whether an object is fractal or not. User friendly graphical interface. Hyper-Fractal Analysis-Test on the Sierpinski hypertetrahedron 4D gasket (Df=ln(5)/ln(2)≅2.32). Running time: In a first approximation, the algorithm is linear [2]. References: [1] V. Grossu, D. Felea, C. Besliu, Al. Jipa, C.C. Bordeianu, E. Stan, T. Esanu, Computer Physics Communications, 181 (2010) 831-832. [2] I.V. Grossu, C. Besliu, M.V. Rusu, Al. Jipa, C. C. Bordeianu, D. Felea, Computer Physics Communications, 180 (2009) 1999-2001. [3] J. Ruiz de Miras, J. Navas, P. Villoslada, F.J. Esteban, Computer Methods and Programs in Biomedicine, 104 Issue 3 (2011) 452-460.
Color constancy in a scene with bright colors that do not have a fully natural surface appearance.
Fukuda, Kazuho; Uchikawa, Keiji
2014-04-01
Theoretical and experimental approaches have proposed that color constancy involves a correction related to some average of stimulation over the scene, and some of the studies showed that the average gives greater weight to surrounding bright colors. However, in a natural scene, high-luminance elements do not necessarily carry information about the scene illuminant when the luminance is too high for it to appear as a natural object color. The question is how a surrounding color's appearance mode influences its contribution to the degree of color constancy. Here the stimuli were simple geometric patterns, and the luminance of surrounding colors was tested over the range beyond the luminosity threshold. Observers performed perceptual achromatic setting on the test patch in order to measure the degree of color constancy and evaluated the surrounding bright colors' appearance mode. Broadly, our results support the assumption that the visual system counts only the colors in the object-color appearance for color constancy. However, detailed analysis indicated that surrounding colors without a fully natural object-color appearance had some sort of influence on color constancy. Consideration of this contribution of unnatural object color might be important for precise modeling of human color constancy.
Arvidsson, Louise; Birkhed, Dowen; Hunsberger, Monica; Lanfer, Anne; Lissner, Lauren; Mehlig, Kirsten; Mårild, Staffan; Eiben, Gabriele
2016-04-01
The objective of the present study was to investigate the association between salivary counts of mutans streptococci (MS) and children's weight status, while considering associated covariates. MS ferments carbohydrates from the diet and contributes to caries by lowering the pH in dental plaque. In adults, high counts of MS in saliva have been associated with overweight, but this has not been shown in children. Cross-sectional study investigating salivary counts of MS, BMI Z-score, waist circumference, meal frequency, sugar propensity and sleep duration, in children. West Sweden. Children (n 271) aged 4-11 years. Medium-high counts of MS were positively associated with higher BMI Z-score (OR=1·6; 95% CI 1·1, 2·3). Positive associations were also found between medium-high counts of MS and more frequent meals per day (OR=1·5; 95% CI 1·1, 2·2), greater percentage of sugar-rich foods consumed (OR=1·1; 95% CI 1·0, 1·3) and female sex (OR=2·4; 95% CI 1·1, 5·4). A negative association was found between medium-high counts of MS and longer sleep duration (OR=0·5; 95% CI 0·3, 1·0). BMI Z-score was associated with counts of MS. Promoting adequate sleep duration and limiting the intake frequency of sugar-rich foods and beverages could provide multiple benefits in public health interventions aimed at reducing dental caries and childhood overweight.
Kinnunen, Tarja I; Tennant, Peter W G; McParlin, Catherine; Poston, Lucilla; Robson, Stephen C; Bell, Ruth
2011-06-27
Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Pregnant women (n = 58) with body mass index ≥25 kg/m(2) at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women.
Seismic intrusion detector system
Hawk, Hervey L.; Hawley, James G.; Portlock, John M.; Scheibner, James E.
1976-01-01
A system for monitoring man-associated seismic movements within a control area including a geophone for generating an electrical signal in response to seismic movement, a bandpass amplifier and threshold detector for eliminating unwanted signals, pulse counting system for counting and storing the number of seismic movements within the area, and a monitoring system operable on command having a variable frequency oscillator generating an audio frequency signal proportional to the number of said seismic movements.
Observer model optimization of a spectral mammography system
NASA Astrophysics Data System (ADS)
Fredenberg, Erik; Åslund, Magnus; Cederström, Björn; Lundqvist, Mats; Danielsson, Mats
2010-04-01
Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. Contrast-enhanced spectral imaging has been thoroughly investigated, but unenhanced imaging may be more useful because it comes as a bonus to the conventional non-energy-resolved absorption image at screening; there is no additional radiation dose and no need for contrast medium. We have used a previously developed theoretical framework and system model that include quantum and anatomical noise to characterize the performance of a photon-counting spectral mammography system with two energy bins for unenhanced imaging. The theoretical framework was validated with synthesized images. Optimal combination of the energy-resolved images for detecting large unenhanced tumors corresponded closely, but not exactly, to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, deteriorated detectability. For small microcalcifications or tumors on uniform backgrounds, however, energy subtraction was suboptimal whereas energy weighting provided a minute improvement. The performance was largely independent of beam quality, detector energy resolution, and bin count fraction. It is clear that inclusion of anatomical noise and imaging task in spectral optimization may yield completely different results than an analysis based solely on quantum noise.
Learning to Count: School Finance Formula Count Methods and Attendance-Related Student Outcomes
ERIC Educational Resources Information Center
Ely, Todd L.; Fermanich, Mark L.
2013-01-01
School systems are under increasing pressure to improve student performance. Several states have recently explored adopting student count methods for school funding purposes that incentivize school attendance and continuous enrollment by adjusting funding for changes in enrollment or attendance over the course of the school year. However, no…
Automatic counting and classification of bacterial colonies using hyperspectral imaging
USDA-ARS?s Scientific Manuscript database
Detection and counting of bacterial colonies on agar plates is a routine microbiology practice to get a rough estimate of the number of viable cells in a sample. There have been a variety of different automatic colony counting systems and software algorithms mainly based on color or gray-scale pictu...
Africa Counts: Number and Pattern in African Culture.
ERIC Educational Resources Information Center
Zaslavsky, Claudia
This document describes the contributions of African peoples to the science of mathematics. The development of a number system is seen as related to need. Names of numbers, time reckoning, gesture counting, and counting materials are examined. Mystical beliefs about numbers and special meanings in pattern are presented. Reproductions of patterns,…
Combined blood cell counting and classification with fluorochrome stains and flow instrumentation.
Shapiro, H M; Schildkraut, E R; Curbelo, R; Laird, C W; Turner, B; Hirschfeld, T
1976-01-01
A multiparameter flow cytophotometer was used to count and classify fixed human blood cells fluorochromed with a mixture of ethidium bromide (EB), brilliant sulfaflavine and a blue fluorescent stilbene disulfonic acid derivative (LN). The system measures light scattered by the cells and absorption at 420 nm for all cells. In addition, nuclear EB fluorescence (540 leads to 610 nm) and cytoplasmic fluorescence from LN (366 leads to 470 nm), brilliant sulfaflavine (420 leads to 520 nm) and EB exicted by energy transfer from LN (366 leads to 610 nm) are measured for all nucleated cells. This information is sufficient to perform red and white blood cell counts and to classify leukocytes as lymphocytes, monocytes, basophils, eosinophils or neutrophils. Light scattering and/or nuclear and cytoplasmic fluorescence values may be further analyzed to obtain the ratio of immature to mature neutrophils. Counts produced by the system are in reasonable agreement with those obtained by electronic cells counting and examination of Wright's-stained blood smears; some discrepancies appear to be due to systematic errors in the manual counting method.
Single Photon Counting UV Solar-Blind Detectors Using Silicon and III-Nitride Materials
Nikzad, Shouleh; Hoenk, Michael; Jewell, April D.; Hennessy, John J.; Carver, Alexander G.; Jones, Todd J.; Goodsall, Timothy M.; Hamden, Erika T.; Suvarna, Puneet; Bulmer, J.; Shahedipour-Sandvik, F.; Charbon, Edoardo; Padmanabhan, Preethi; Hancock, Bruce; Bell, L. Douglas
2016-01-01
Ultraviolet (UV) studies in astronomy, cosmology, planetary studies, biological and medical applications often require precision detection of faint objects and in many cases require photon-counting detection. We present an overview of two approaches for achieving photon counting in the UV. The first approach involves UV enhancement of photon-counting silicon detectors, including electron multiplying charge-coupled devices and avalanche photodiodes. The approach used here employs molecular beam epitaxy for delta doping and superlattice doping for surface passivation and high UV quantum efficiency. Additional UV enhancements include antireflection (AR) and solar-blind UV bandpass coatings prepared by atomic layer deposition. Quantum efficiency (QE) measurements show QE > 50% in the 100–300 nm range for detectors with simple AR coatings, and QE ≅ 80% at ~206 nm has been shown when more complex AR coatings are used. The second approach is based on avalanche photodiodes in III-nitride materials with high QE and intrinsic solar blindness. PMID:27338399
Gaglani, Shiv; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele
2015-01-01
Objectives: This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. Methods: This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Results: Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. Conclusions: These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested. PMID:26719825
Association Between HIV-1 RNA Level and CD4 Cell Count Among Untreated HIV-Infected Individuals
Lima, Viviane D.; Fink, Valeria; Yip, Benita; Hogg, Robert S.; Harrigan, P. Richard
2009-01-01
Objectives. We examined the significance of plasma HIV-1 RNA levels (or viral load alone) in predicting CD4 cell decline in untreated HIV-infected individuals. Methods. Data were obtained from the British Columbia Centre for Excellence in HIV/AIDS. Participants included all residents who ever had a viral load determination in the province and who had never taken antiretroviral drugs (N = 890). We analyzed a total of 2074 viral load measurements and 2332 CD4 cell counts. Linear mixed-effects models were used to predict CD4 cell decline over time. Results. Longitudinal viral load was strongly associated with CD4 cell decline over time; an average of 1 log10 increase in viral load was associated with a 55-cell/mm3 decrease in CD4 cell count. Conclusions. Our results support the combined use of CD4 cell count and viral load as prognostic markers in HIV-infected individuals before the introduction of antiretroviral therapy. PMID:19218172
The effects of proficiency and bias on residents' interpretation of the microscopic urinalysis.
Flach, Stephen D; Canaris, Gay J; Tape, Thomas G; Huntley, Kathryn M; Wigton, Robert S
2002-01-01
This study aims to determine whether residents are influenced by clinical information when interpreting microscopic urinalysis (UA) and estimating the probability of a urinary tract infection (UTI), and to determine the accuracy and reliability of UA readings. Residents estimated the UA white blood cell count and the probability of a UTI in vignettes using a fractional factorial design, varying symptoms, gender, and the white blood cell count on preprepared urine slides. Individual-level results indicated a clinical information bias and poor accuracy. Seventeen of 38 residents increased the white blood cell count in response to female gender; 14 increased the white blood cell count in response to UTI symptoms. Forty-nine percent of the readings were inaccurate; agreement ranged from 50% to 67% for white and red blood cells and bacteria. Many residents gave inaccurate UA readings, and many readings varied with clinical information. A significant portion of residents needs assistance in objectively and accurately interpreting the UA.
Single Photon Counting UV Solar-Blind Detectors Using Silicon and III-Nitride Materials.
Nikzad, Shouleh; Hoenk, Michael; Jewell, April D; Hennessy, John J; Carver, Alexander G; Jones, Todd J; Goodsall, Timothy M; Hamden, Erika T; Suvarna, Puneet; Bulmer, J; Shahedipour-Sandvik, F; Charbon, Edoardo; Padmanabhan, Preethi; Hancock, Bruce; Bell, L Douglas
2016-06-21
Ultraviolet (UV) studies in astronomy, cosmology, planetary studies, biological and medical applications often require precision detection of faint objects and in many cases require photon-counting detection. We present an overview of two approaches for achieving photon counting in the UV. The first approach involves UV enhancement of photon-counting silicon detectors, including electron multiplying charge-coupled devices and avalanche photodiodes. The approach used here employs molecular beam epitaxy for delta doping and superlattice doping for surface passivation and high UV quantum efficiency. Additional UV enhancements include antireflection (AR) and solar-blind UV bandpass coatings prepared by atomic layer deposition. Quantum efficiency (QE) measurements show QE > 50% in the 100-300 nm range for detectors with simple AR coatings, and QE ≅ 80% at ~206 nm has been shown when more complex AR coatings are used. The second approach is based on avalanche photodiodes in III-nitride materials with high QE and intrinsic solar blindness.
Pulse pileup statistics for energy discriminating photon counting x-ray detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Adam S.; Harrison, Daniel; Lobastov, Vladimir
Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analyticallymore » for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.« less
High-throughput measurement of rice tillers using a conveyor equipped with x-ray computed tomography
NASA Astrophysics Data System (ADS)
Yang, Wanneng; Xu, Xiaochun; Duan, Lingfeng; Luo, Qingming; Chen, Shangbin; Zeng, Shaoqun; Liu, Qian
2011-02-01
Tillering is one of the most important agronomic traits because the number of shoots per plant determines panicle number, a key component of grain yield. The conventional method of counting tillers is still manual. Under the condition of mass measurement, the accuracy and efficiency could be gradually degraded along with fatigue of experienced staff. Thus, manual measurement, including counting and recording, is not only time consuming but also lack objectivity. To automate this process, we developed a high-throughput facility, dubbed high-throughput system for measuring automatically rice tillers (H-SMART), for measuring rice tillers based on a conventional x-ray computed tomography (CT) system and industrial conveyor. Each pot-grown rice plant was delivered into the CT system for scanning via the conveyor equipment. A filtered back-projection algorithm was used to reconstruct the transverse section image of the rice culms. The number of tillers was then automatically extracted by image segmentation. To evaluate the accuracy of this system, three batches of rice at different growth stages (tillering, heading, or filling) were tested, yielding absolute mean absolute errors of 0.22, 0.36, and 0.36, respectively. Subsequently, the complete machine was used under industry conditions to estimate its efficiency, which was 4320 pots per continuous 24 h workday. Thus, the H-SMART could determine the number of tillers of pot-grown rice plants, providing three advantages over the manual tillering method: absence of human disturbance, automation, and high throughput. This facility expands the application of agricultural photonics in plant phenomics.
Yang, Wanneng; Xu, Xiaochun; Duan, Lingfeng; Luo, Qingming; Chen, Shangbin; Zeng, Shaoqun; Liu, Qian
2011-02-01
Tillering is one of the most important agronomic traits because the number of shoots per plant determines panicle number, a key component of grain yield. The conventional method of counting tillers is still manual. Under the condition of mass measurement, the accuracy and efficiency could be gradually degraded along with fatigue of experienced staff. Thus, manual measurement, including counting and recording, is not only time consuming but also lack objectivity. To automate this process, we developed a high-throughput facility, dubbed high-throughput system for measuring automatically rice tillers (H-SMART), for measuring rice tillers based on a conventional x-ray computed tomography (CT) system and industrial conveyor. Each pot-grown rice plant was delivered into the CT system for scanning via the conveyor equipment. A filtered back-projection algorithm was used to reconstruct the transverse section image of the rice culms. The number of tillers was then automatically extracted by image segmentation. To evaluate the accuracy of this system, three batches of rice at different growth stages (tillering, heading, or filling) were tested, yielding absolute mean absolute errors of 0.22, 0.36, and 0.36, respectively. Subsequently, the complete machine was used under industry conditions to estimate its efficiency, which was 4320 pots per continuous 24 h workday. Thus, the H-SMART could determine the number of tillers of pot-grown rice plants, providing three advantages over the manual tillering method: absence of human disturbance, automation, and high throughput. This facility expands the application of agricultural photonics in plant phenomics.
NASA Astrophysics Data System (ADS)
Eriksson, L.; Wienhard, K.; Eriksson, M.; Casey, M. E.; Knoess, C.; Bruckbauer, T.; Hamill, J.; Mulnix, T.; Vollmar, S.; Bendriem, B.; Heiss, W. D.; Nutt, R.
2002-06-01
The first and second generation of the Exact and Exact HR family of scanners has been evaluated in terms of noise equivalent count rate (NEC) and count-rate capabilities. The new National Electrical Manufacturers Association standard was used for the evaluation. In spite of improved electronics and improved count-rate capabilities, the peak NEC was found to be fairly constant between the generations. The results are discussed in terms of the different electronic solutions for the two generations and its implications on system dead time and NEC count-rate capability.
Hudson, M J; Green, A E
1980-11-01
Visual differential counts were examined for efficiency, cost effectiveness, and staff acceptability within our laboratory. A comparison with the Hemalog D system was attempted. The advantages and disadvantages of each system are enumerated and discussed in the context of a large general hospital.
Nutrition Counts. Massachusetts Nutrition Surveillance System. FY90 Annual Report.
ERIC Educational Resources Information Center
Wiecha, Jean L.; And Others
"Nutrition Counts," the pediatric portion of the Massachusetts Department of Public Health's (MDPH) Nutrition Surveillance System, monitors and describes aspects of nutritional status among groups of young children in the state. This report presents cross-sectional data describing 5,176 infants and young children in Massachusetts. Of…
De la Salle, Barbara
2017-02-15
The complete blood count (CBC) is one of the most frequently requested tests in laboratory medicine, performed in a range of healthcare situations. The provision of an ideal assay material for external quality assessment is confounded by the fragility of the cellular components of blood, the lack of commutability of stabilised whole blood material and the lack of certified reference materials and methods to which CBC results can be traced. The choice of assay material between fresh blood, extended life assay material and fully stabilised, commercially prepared, whole blood material depends upon the scope and objectives of the EQA scheme. The introduction of new technologies in blood counting and the wider clinical application of parameters from the extended CBC will bring additional challenges for the EQA provider.
EDITORIAL: Topological data analysis Topological data analysis
NASA Astrophysics Data System (ADS)
Epstein, Charles; Carlsson, Gunnar; Edelsbrunner, Herbert
2011-12-01
Inverse problems can be defined as the area of mathematics that attempts to reconstruct a physical or mathematical object from derived data. Frequently, this means the evaluation of parameters or other numerical quantities (such as eigenvalues) that characterize or provide information about the system. There are, however, other aspects of a system that are important, but are not as readily summarized by numerical quantities. If one considers observations of diabetic patients (using metabolic quantities), one will find that the data breaks up into components, or pieces, corresponding to distinct forms of the disease. The decomposition of data sets into disjoint pieces, or clustering, is an aspect of the study of the shape of the data, albeit one that has been extensively studied. A more complex notion of shape appears in observations of a predator-prey system governed by a Lotka-Volterra equation. One would find that exact observations, consisting of (prey population, predator population) pairs, appear to lie along a simple closed curve in the plane. The fact that the data lies along such a closed curve is an important piece of information, since it suggests that the system displays recurrent behavior. If one did not know, a priori, that the system is governed by a Lotka-Volterra equation, then it would not be immediately obvious that the system is undergoing recurrent motion, and this deduction would constitute a significant insight. In this case, it is again the shape of the data, namely the fact that it lies on a simple closed curve, which is the key insight. Shape is a somewhat nebulous concept, which at first blush may be too intuitive to make precise mathematically, and describe quantitatively. Within pure mathematics, the disciplines of topology and differential geometry are designed exactly to address this problem. They provide explicit signatures which, in precise senses, quantify and describe the shape of a geometric object. In addition, they provide methods for discretizing and compressing the information present in a geometric object so as to provide a useful, small representation of the object. The articles in this special issue are concerned with the applications of topology to the analysis of data sets. The adaptation of topological techniques from pure mathematics to the study of data from real systems is a project which has been undertaken during the past two decades, and the present volume contains various contributions to that project. At the current state of development, homology and persistence are two of the most popular topological techniques used in this context. Homology goes back to the beginnings of topology in Poincaré's influential papers. It is the idea that the connectivity of a space is determined by its cycles of different dimensions, and that these cycles organize themselves into abelian groups, called homology groups. Better known than these groups are their ranks, the Betti numbers of the space, which are non-negative integers that count the number of independent cycles in each dimension. To give an example, the zeroth Betti number counts the components, and the first counts the loops. A crucial feature of homology groups is that, given a reasonably explicit description of a space, their computation is an exercise in linear algebra. Even better known than the Betti numbers is the Euler characteristic, which we know from Poincaré's work, is equal to the alternating sum of the Betti numbers, which can be computed without computing the homology groups themselves. To give evidence that these numbers have relevant practical applications, we mention that integrating the Euler characteristic over a domain with sensor information can be used to count objects in the domain. This alone would not explain the popularity of homology groups, which we see rooted in the fact that they hit a sweet-spot that offers relatively strong discriminative power, and a clear intuitive meaning, all at a surprisingly low computational cost. Even these desirable qualities would not be sufficient if it were not possible to overcome a serious shortcoming, namely the high sensitivity of homology to minor mistakes in the data collection. Because of the finite nature of most data sets, the notion of shape within data sets is inevitably stochastic. To some extent this is because of the uncertainty of what a shape in nature is, but more importantly, the available data can only be used to give an estimate for the probability of a given shape. This has led to the study of persistent homology, in which the invariants are in the form of 'persistence diagrams' or 'barcodes'. These invariants quantify the stability of geometric features with respect to perturbations that, in turn, provide a basis for discriminating between artifacts caused by noise or undersampling and real phenomena. Several papers in this volume deal with questions about these diagrams, and some deal with probabilistic issues related to the occurrence of these diagrams. Our hope is that the papers in this volume will provide exposure of these techniques to both a wider audience of mathematicians and also potential users of the techniques.
EDITORIAL: Topological data analysis Topological data analysis
NASA Astrophysics Data System (ADS)
2011-12-01
Inverse problems can be defined as the area of mathematics that attempts to reconstruct a physical or mathematical object from derived data. Frequently, this means the evaluation of parameters or other numerical quantities (such as eigenvalues) that characterize or provide information about the system. There are, however, other aspects of a system that are important, but are not as readily summarized by numerical quantities. If one considers observations of diabetic patients (using metabolic quantities), one will find that the data breaks up into components, or pieces, corresponding to distinct forms of the disease. The decomposition of data sets into disjoint pieces, or clustering, is an aspect of the study of the shape of the data, albeit one that has been extensively studied. A more complex notion of shape appears in observations of a predator-prey system governed by a Lotka-Volterra equation. One would find that exact observations, consisting of (prey population, predator population) pairs, appear to lie along a simple closed curve in the plane. The fact that the data lies along such a closed curve is an important piece of information, since it suggests that the system displays recurrent behavior. If one did not know, a priori, that the system is governed by a Lotka-Volterra equation, then it would not be immediately obvious that the system is undergoing recurrent motion, and this deduction would constitute a significant insight. In this case, it is again the shape of the data, namely the fact that it lies on a simple closed curve, which is the key insight. Shape is a somewhat nebulous concept, which at first blush may be too intuitive to make precise mathematically, and describe quantitatively. Within pure mathematics, the disciplines of topology and differential geometry are designed exactly to address this problem. They provide explicit signatures which, in precise senses, quantify and describe the shape of a geometric object. In addition, they provide methods for discretizing and compressing the information present in a geometric object so as to provide a useful, small representation of the object. The articles in this special issue are concerned with the applications of topology to the analysis of data sets. The adaptation of topological techniques from pure mathematics to the study of data from real systems is a project which has been undertaken during the past two decades, and the present volume contains various contributions to that project. At the current state of development, homology and persistence are two of the most popular topological techniques used in this context. Homology goes back to the beginnings of topology in Poincaré's influential papers. It is the idea that the connectivity of a space is determined by its cycles of different dimensions, and that these cycles organize themselves into abelian groups, called homology groups. Better known than these groups are their ranks, the Betti numbers of the space, which are non-negative integers that count the number of independent cycles in each dimension. To give an example, the zeroth Betti number counts the components, and the first counts the loops. A crucial feature of homology groups is that, given a reasonably explicit description of a space, their computation is an exercise in linear algebra. Even better known than the Betti numbers is the Euler characteristic, which we know from Poincaré's work, is equal to the alternating sum of the Betti numbers, which can be computed without computing the homology groups themselves. To give evidence that these numbers have relevant practical applications, we mention that integrating the Euler characteristic over a domain with sensor information can be used to count objects in the domain. This alone would not explain the popularity of homology groups, which we see rooted in the fact that they hit a sweet-spot that offers relatively strong discriminative power, and a clear intuitive meaning, all at a surprisingly low computational cost. Even these desirable qualities would not be sufficient if it were not possible to overcome a serious shortcoming, namely the high sensitivity of homology to minor mistakes in the data collection. Because of the finite nature of most data sets, the notion of shape within data sets is inevitably stochastic. To some extent this is because of the uncertainty of what a shape in nature is, but more importantly, the available data can only be used to give an estimate for the probability of a given shape. This has led to the study of persistent homology, in which the invariants are in the form of 'persistence diagrams' or 'barcodes'. These invariants quantify the stability of geometric features with respect to perturbations that, in turn, provide a basis for discriminating between artifacts caused by noise or undersampling and real phenomena. Several papers in this volume deal with questions about these diagrams, and some deal with probabilistic issues related to the occurrence of these diagrams. Our hope is that the papers in this volume will provide exposure of these techniques to both a wider audience of mathematicians and also potential users of the techniques. Charles Epstein, Gunnar Carlsson and Herbert Edelsbrunner Guest Editors
McCarron, J L; Keefe, G P; McKenna, S L B; Dohoo, I R; Poole, D E
2009-05-01
The objective was to determine test characteristics and compare 2 potential on-farm culture systems for clinical mastitis, the Minnesota Easy Culture System II Bi-plate and Petrifilm. The tests were evaluated using clinically positive mastitic milk samples (n = 282) to determine their ability to differentiate appropriate treatment groups; all cases that had gram-positive growth were considered treatment candidates (n = 161), whereas cases that grew gram-negative organisms only or yielded no bacterial growth were classified as no treatment (n = 121). For Petrifilm, both undiluted and 1:10 diluted milk samples were used. To create treatment categories, 2 types of Petrifilms were used, Aerobic Count (AC) and Coliform Count (CC). Both Bi-plates and Petrifilms were read after 24 h of incubation. Analysis was conducted at various colony count thresholds for the Petrifilm test system. The combination of Petrifilms that had the highest sensitivity classified a case as gram-negative if there were > or =20 colonies present on the CC. If there were <20 colonies present on the CC and >5 colonies present on the AC, a case would be classified as gram-positive. The Bi-plate had a sensitivity of 97.9% and a specificity of 68.6%. The Petrifilm test system had a sensitivity of 93.8% and a specificity of 70.1%. There was no significant difference in the sensitivities between the tests. All Bi-plates and Petrifilms were read by a laboratory technician and a group of masked readers with limited microbiology training. Kappa values for the masked readers were 0.75 for Bi-plates and 0.84 and 0.86 for AC and CC Petrifilms, respectively. The Bi-plate and Petrifilm were able to successfully categorize clinical cases of mastitis into 2 treatments based on their ability to detect the presence of a gram-positive organism. Neither method had the ability to determine if a sample was contaminated. The results of this study indicate that both tests were able to appropriately categorize cases, which could potentially result in a reduction in the quantity of antibiotics used to treat clinical cases of mastitis.
Experimental evaluation of penetration capabilities of a Geiger-mode APD array laser radar system
NASA Astrophysics Data System (ADS)
Jonsson, Per; Tulldahl, Michael; Hedborg, Julia; Henriksson, Markus; Sjöqvist, Lars
2017-10-01
Laser radar 3D imaging has the potential to improve target recognition in many scenarios. One case that is challenging for most optical sensors is to recognize targets hidden in vegetation or behind camouflage. The range resolution of timeof- flight 3D sensors allows segmentation of obscuration and target if the surfaces are separated far enough so that they can be resolved as two distances. Systems based on time-correlated single-photon counting (TCSPC) have the potential to resolve surfaces closer to each other compared to laser radar systems based on proportional mode detection technologies and is therefore especially interesting. Photon counting detection is commonly performed with Geigermode Avalanche Photodiodes (GmAPD) that have the disadvantage that they can only detect one photon per laser pulse per pixel. A strong return from an obscuring object may saturate the detector and thus limit the possibility to detect the hidden target even if photons from the target reach the detector. The operational range where good foliage penetration is observed is therefore relatively narrow for GmAPD systems. In this paper we investigate the penetration capability through semi-transparent surfaces for a laser radar with a 128×32 pixel GmAPD array and a 1542 nm wavelength laser operating at a pulse repetition frequency of 90 kHz. In the evaluation a screen was placed behind different canvases with varying transmissions and the detected signals from the surfaces for different laser intensities were measured. The maximum return from the second surface occurs when the total detection probability is around 0.65-0.75 per pulse. At higher laser excitation power the signal from the second surface decreases. To optimize the foliage penetration capability it is thus necessary to adaptively control the laser power to keep the returned signal within this region. In addition to the experimental results, simulations to study the influence of the pulse energy on penetration through foliage in a scene with targets behind vegetation are presented. The optimum detection of targets occurs here at a slightly higher total photon count rate probability because a number of pixel have no obscuration in front the target in their field of view.
Microradiography with Semiconductor Pixel Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jakubek, Jan; Cejnarova, Andrea; Dammer, Jiri
High resolution radiography (with X-rays, neutrons, heavy charged particles, ...) often exploited also in tomographic mode to provide 3D images stands as a powerful imaging technique for instant and nondestructive visualization of fine internal structure of objects. Novel types of semiconductor single particle counting pixel detectors offer many advantages for radiation imaging: high detection efficiency, energy discrimination or direct energy measurement, noiseless digital integration (counting), high frame rate and virtually unlimited dynamic range. This article shows the application and potential of pixel detectors (such as Medipix2 or TimePix) in different fields of radiation imaging.
Cheung, Felix; Loeb, Charles A; Croglio, Michael P; Waltzer, Wayne C; Weissbart, Steven J
2017-09-01
Determining whether bacterial presence in urine microscopy represents infection is important as ureteral stent placement is indicated in patients with obstructing urolithiasis and infection. We aim to investigate whether the presence of bacteria on urine microscopy is associated with other markers of infection in patients with obstructing urolithiasis presenting to the emergency room. We performed a cross-sectional study of 199 patients with obstructing urolithiasis and divided patients into two groups according to the presence of bacteria on urine microscopy. The primary outcome was serum white blood cell count and secondary outcomes were objective fever, subjective fever, tachycardia, pyuria, and final urine culture. Univariate and multivariate analysis were used to assess whether the presence of bacteria on microscopy was associated with other markers of infection. The study included 72 patients in the bacteriuria group and 127 without bacteriuria. On univariate analysis, the presence of bacteria was not associated with leukocytosis, objective fever, or subjective fever, but it was associated with gender (p < 0.001), pyuria (p < 0.001), positive nitrites (p = 0.001), positive leukocyte esterase (p < 0.001), and squamous epithelial cells (p = 0.002). In a multilinear regression model including the presence of squamous cells, age, and sex, the presence of bacteriuria was not related to serum white blood cell count (coefficient -0.47; 95% confidence interval [CI] -1.1, 0.2; p = 0.17), heart rate (coefficient 0.85; 95% CI -2.5, 4.2; p = 0.62), presence of subjective or objective fever (odds ratio [OR] 1.5; 95% CI 0.8, 3.1; p = 0.18), or the presence of squamous epithelial cells (coefficient -4.4; 95% CI -10, 1.2; p = 0.12). However, the presence of bacteriuria was related to only the degree of pyuria (coefficient 16.4; 95% CI 9.6, 23.3; p < 0.001). Bacteria on urine microscopy is not associated with other markers of systemic infection and may largely represent a contaminant. Renal colic may be a risk factor for providing a contaminated urine specimen.
Moretti, Pierangelo; Probo, Monica; Cantoni, Andrea; Paltrinieri, Saverio; Giordano, Alessia
2016-08-01
Retained placenta (RP) is often diagnosed in high-yielding dairy cows and can negatively affect reproductive performances. The objective of the present study was to investigate the hematological and biochemical profile of cows with RP before and immediately after parturition, with particular emphasis on neutrophil counts, since a previous study demonstrated the presence of peripheral neutropenia in dairy cows with RP sampled a few days after parturition. Results from 12 Holstein cows affected by RP and from 17 clinically healthy controls sampled one week pre-partum, within 12h after calving and between 48 and 72h after parturition were compared between groups and over time. Compared with controls, cows with RP had lower lymphocyte counts before parturition, lower leukocyte and neutrophil counts at parturition, lower monocyte counts at all times, and higher β-hydroxybutyrate before and after parturition. Erythroid and biochemical parameters were similar over time in both groups, whereas RP cows did not show the increase of neutrophil counts that occurs in controls at parturition. Hence, the finding of a lower neutrophil count in a routinely hemogram performed at parturition could be used as an alarm signal suggesting to monitor the affected animals. Moreover, although the underlying pathogenetic mechanism should be better investigated, the present study describes for the first time the association between altered blood leukocyte concentrations at parturition in RP compared to control cows. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pothakos, Vasileios; Samapundo, Simbarashe; Devlieghere, Frank
2012-12-01
The major objective of this study was to determine the role of psychrotrophic lactic acid bacteria (LAB) in spoilage-associated phenomena at the end of the shelf-life of 86 various packaged (air, vacuum, modified-atmosphere) chilled-stored retail food products. The current microbiological standards, which are largely based on the total viable mesophilic counts lack discriminatory capacity to detect psychrotrophic LAB. A comparison between the total viable counts on plates incubated at 30 °C (representing the mesophiles) and at 22 °C (indicating the psychrotrophs) for 86 food samples covering a wide range - ready-to-eat vegetable salads, fresh raw meat, cooked meat products and composite food - showed that a consistent underestimation of the microbial load occurs when the total aerobic mesophilic counts are used as a shelf-life parameter. In 38% of the samples, the psychrotrophic counts had significantly higher values (+0.5-3 log CFU/g) than the corresponding total aerobic mesophilic counts. A total of 154 lactic acid bacteria, which were unable to proliferate at 30 °C were isolated. In addition, a further 43 with a poor recovery at this temperature were also isolated. This study highlights the potential fallacy of the total aerobic mesophilic count as a reference shelf-life parameter for chilled food products as it can often underestimate the contamination levels at the end of the shelf-life. Copyright © 2012 Elsevier Ltd. All rights reserved.
XRF Experiment for Elementary Surface Analysis
NASA Astrophysics Data System (ADS)
Köhler, E.; Dreißigacker, A.; Fabel, O.; van Gasselt, S.; Meyer, M.
2014-04-01
The proposed X-Ray Fluorescence Instrument Package (XRF-X and XRF-E) is being designed to quantitatively measure the composition and map the distribution of rock-surface materials in order to support the target area selection process for exploration, sampling, and mining. While energydispersive X-Ray fluorescence (EDX) makes use of Solar X-Rays for excitation to probe materials over arbitrary distances (by XRF-X), electron-beam excitation can be used for proximity measurements (by XRF-E) over short-distance of up to about 10 - 20m. This design is targeted at observing and analyzing surface compositions from orbital platforms and it is in particular applicable to all atmosphereless solidsurface bodies. While the instrument design for observing objects in the outer solar system is challenging due to low count rates, the Moon and objects of the asteroid belt usually receive solar X-ray radiation that allows to integrate a statistically reliable data basis. Asteroids are attractive targets and have been visited using X-ray fluorescence instruments by orbiting spacecraft in the past (Itokawa, Eros). They are wellaccessible objects for determining elemental compositions and assessing potential mineral resources.
Sanci, Muzaffer; Töz, Emrah; Ince, Onur; Özcan, Aykut; Polater, Kevser; Inan, Abdurrahman Hamdi; Beyan, Emrah; Akkaya, Emrah
2017-07-01
The aim of this study was to investigate alterations in the leukocyte and differential leukocyte counts in different trimesters of pregnancy and the initial postpartum period. The study population consisted of 40,325 pregnant women. A full blood count and automated differential leukocyte count were performed and all the haemogram results in the different trimesters of pregnancy were recorded. Percentiles were calculated using statistical software. A total of 82,786 complete blood count evaluations were performed in 40,325 subjects from the 6th to 41st week of pregnancy and in the initial postpartum period. The leukocyte counts increased from the 1st to the 3rd trimester and peaked in the initial postpartum period. Our reference values for the total and differential leukocyte counts may assist clinicians in distinguishing between leukocytosis and pathological elevation of the white blood cell count during pregnancy and the initial postpartum period. Impact statement Pregnancy requires profound adaptation by multiple systems to accommodate the demands of the developing foetus. Similar to all other systems, many haematological changes occur during pregnancy. Studies of normal variation in leukocyte counts were insufficient to distinguish normal from abnormal leukocyte counts during pregnancy and in the initial postpartum period, due to small numbers of patients and a lack of differential leukocyte counts. Without reference leukocyte levels, infections may be more difficult to assess during pregnancy and in the postpartum period. In this study, we report the 3rd, 5th, 10th, 50th, 95th and 99th percentile values for the total and differential leukocyte counts according to trimester in normal pregnancy and the initial postpartum period. Our reference values for the total and differential leukocyte counts in each trimester and the initial postpartum period may assist clinicians in distinguishing between normal leukocytosis and pathological elevation of the white blood cell count during pregnancy and the initial postpartum period. Our results may prevent misdiagnosis of physiological elevated leukocytes as bacterial infection that leads to unnecessary medication use that may compromise the foetus.
Information theoretic approach for assessing image fidelity in photon-counting arrays.
Narravula, Srikanth R; Hayat, Majeed M; Javidi, Bahram
2010-02-01
The method of photon-counting integral imaging has been introduced recently for three-dimensional object sensing, visualization, recognition and classification of scenes under photon-starved conditions. This paper presents an information-theoretic model for the photon-counting imaging (PCI) method, thereby providing a rigorous foundation for the merits of PCI in terms of image fidelity. This, in turn, can facilitate our understanding of the demonstrated success of photon-counting integral imaging in compressive imaging and classification. The mutual information between the source and photon-counted images is derived in a Markov random field setting and normalized by the source-image's entropy, yielding a fidelity metric that is between zero and unity, which respectively corresponds to complete loss of information and full preservation of information. Calculations suggest that the PCI fidelity metric increases with spatial correlation in source image, from which we infer that the PCI method is particularly effective for source images with high spatial correlation; the metric also increases with the reduction in photon-number uncertainty. As an application to the theory, an image-classification problem is considered showing a congruous relationship between the fidelity metric and classifier's performance.
Neonatal nucleated red blood cells in G6PD deficiency.
Yeruchimovich, Mark; Shapira, Boris; Mimouni, Francis B; Dollberg, Shaul
2002-05-01
The objective of this study is to study the absolute number of nucleated red blood cells (RBC) at birth, an index of active fetal erythropoiesis, in infants with G6PD deficiency and in controls. We tested the hypothesis that hematocrit and hemoglobin would be lower, and absolute nucleated RBC counts higher, in the G6PD deficient and that these changes would be more prominent in infants exposed passively to fava bean through maternal diet. Thirty-two term infants with G6PD deficiency were compared with 30 term controls. Complete blood counts with manual differential counts were obtained within 12 hours of life. Absolute nucleated RBC and corrected leukocyte counts were computed from the Coulter results and the differential count. G6PD deficient patients did not differ from controls in terms of gestational age, birth weight, or Apgar scores or in any of the hematologic parameters studied, whether or not the mother reported fava beans consumption in the days prior to delivery. Although intrauterine hemolysis is possible in G6PD deficient fetuses exposed passively to fava beans, our study supports that such events must be very rare.
Vattem, DA; Lester, CE; DeLeon, RC; Jamison, BY; Maitin, V
2013-01-01
Introduction: Lamiaceae herbs have are well known for their immunomodulatory effects, however, the mechanism by which they effect innate immune system is not clearly understood. Objective: The effect of dietary supplementation with two Lamiaceae herbs (oregano and sage) modulation of on innate immunological parameters was investigated in Lumbricus terrestris. Materials and Methods: Animals were fed (ad libitum) on herbs supplemented diet [(0.1% (w/v) and 0.5% (w/v)] for 6 days. Changes in immune competent cell counts, viability, and relative neutrophil-like cell counts were determined in response to herb treatment. Changes in nitric oxide, phagocytic activity, and respiratory burst index were also determined in response to herb treatment relative to control. Additionally, effect of herb co-treatment cyclophosphamide (50 mg/kg-BW) induced immunosuppression was also evaluated. Results: Our results suggested abrogation of CP-induced immunosuppression in response to co-treatment with herbs. Significant increase in nitric oxide-mediated immune-competent cell counts, viability, and differentiation into neutrophil-like cells were observed in response to dietary supplementation with Lamiaceae herbs. Significantly higher phagocytic activity relative to control was also noted in response to dietary intake of oregano and sage. However, the respiratory burst index did not increase exponentially in response to herb treatments, suggesting a potential enhancement in pathogen recognition and antioxidant defenses. Conclusion: Lamiaceae herbs may have potential immune-modulatory properties important for human health and merits further investigation. PMID:23598918
Methodology for creating dedicated machine and algorithm on sunflower counting
NASA Astrophysics Data System (ADS)
Muracciole, Vincent; Plainchault, Patrick; Mannino, Maria-Rosaria; Bertrand, Dominique; Vigouroux, Bertrand
2007-09-01
In order to sell grain lots in European countries, seed industries need a government certification. This certification requests purity testing, seed counting in order to quantify specified seed species and other impurities in lots, and germination testing. These analyses are carried out within the framework of international trade according to the methods of the International Seed Testing Association. Presently these different analyses are still achieved manually by skilled operators. Previous works have already shown that seeds can be characterized by around 110 visual features (morphology, colour, texture), and thus have presented several identification algorithms. Until now, most of the works in this domain are computer based. The approach presented in this article is based on the design of dedicated electronic vision machine aimed to identify and sort seeds. This machine is composed of a FPGA (Field Programmable Gate Array), a DSP (Digital Signal Processor) and a PC bearing the GUI (Human Machine Interface) of the system. Its operation relies on the stroboscopic image acquisition of a seed falling in front of a camera. A first machine was designed according to this approach, in order to simulate all the vision chain (image acquisition, feature extraction, identification) under the Matlab environment. In order to perform this task into dedicated hardware, all these algorithms were developed without the use of the Matlab toolbox. The objective of this article is to present a design methodology for a special purpose identification algorithm based on distance between groups into dedicated hardware machine for seed counting.
Oliveira, A T; Araújo, M L G; Lemos, J R G; Santos, M Q C; Pantoja-Lima, J; Aride, P H R; Tavares-Dias, M; Marcon, J L
2017-01-01
The objective of this study was to compare and correlate the ecology of neonates and young individuals of Potamotrygon wallacei, Potamotrygon motoro and Paratrygon aiereba with regard to their hematological profile and the physicochemical parameters of the water that they inhabit. Principal component analysis (PCA) on the complete blood count revealed total variation of 72.92%, thus demonstrating a differentiation system for oxygen demand. On the other hand, P. motoro was considered to be an intermediate species, given that its complete blood count characteristics interacted with both P. wallacei and with P. aiereba. The interaction among the biochemical variables was shown to total 64.67% of the factors. This allowed differentiation of P. wallacei from P. aiereba, while P. motoro maintained an intermediate position. These characteristics of differentiation within the preferred environment corroborate the PCA of the present study and confirm that these species can be differentiated through considering the complete blood count and biochemical parameters. The PCA on water properties showed 68.57% differentiation, mainly comprising the x axis (49.44%). It can be affirmed that P. motoro has the capacity to inhabit the preferential areas of P. wallacei and P. aiereba, as well as occupying localities in which other stingrays are not found. In conclusion, P. wallacei presents patterns differentiating it from P. aiereba, while P. motoro is a species that presents intermediate characteristics. The latter can be considered to be a more broadly distributed species regarding its ecophysiological characteristics.
Artificial neural network-aided image analysis system for cell counting.
Sjöström, P J; Frydel, B R; Wahlberg, L U
1999-05-01
In histological preparations containing debris and synthetic materials, it is difficult to automate cell counting using standard image analysis tools, i.e., systems that rely on boundary contours, histogram thresholding, etc. In an attempt to mimic manual cell recognition, an automated cell counter was constructed using a combination of artificial intelligence and standard image analysis methods. Artificial neural network (ANN) methods were applied on digitized microscopy fields without pre-ANN feature extraction. A three-layer feed-forward network with extensive weight sharing in the first hidden layer was employed and trained on 1,830 examples using the error back-propagation algorithm on a Power Macintosh 7300/180 desktop computer. The optimal number of hidden neurons was determined and the trained system was validated by comparison with blinded human counts. System performance at 50x and lO0x magnification was evaluated. The correlation index at 100x magnification neared person-to-person variability, while 50x magnification was not useful. The system was approximately six times faster than an experienced human. ANN-based automated cell counting in noisy histological preparations is feasible. Consistent histology and computer power are crucial for system performance. The system provides several benefits, such as speed of analysis and consistency, and frees up personnel for other tasks.
Compton suppression gamma-counting: The effect of count rate
Millard, H.T.
1984-01-01
Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.
Real-time bacterial microcolony counting using on-chip microscopy
NASA Astrophysics Data System (ADS)
Jung, Jae Hee; Lee, Jung Eun
2016-02-01
Observing microbial colonies is the standard method for determining the microbe titer and investigating the behaviors of microbes. Here, we report an automated, real-time bacterial microcolony-counting system implemented on a wide field-of-view (FOV), on-chip microscopy platform, termed ePetri. Using sub-pixel sweeping microscopy (SPSM) with a super-resolution algorithm, this system offers the ability to dynamically track individual bacterial microcolonies over a wide FOV of 5.7 mm × 4.3 mm without requiring a moving stage or lens. As a demonstration, we obtained high-resolution time-series images of S. epidermidis at 20-min intervals. We implemented an image-processing algorithm to analyze the spatiotemporal distribution of microcolonies, the development of which could be observed from a single bacterial cell. Test bacterial colonies with a minimum diameter of 20 μm could be enumerated within 6 h. We showed that our approach not only provides results that are comparable to conventional colony-counting assays but also can be used to monitor the dynamics of colony formation and growth. This microcolony-counting system using on-chip microscopy represents a new platform that substantially reduces the detection time for bacterial colony counting. It uses chip-scale image acquisition and is a simple and compact solution for the automation of colony-counting assays and microbe behavior analysis with applications in antibacterial drug discovery.
Real-time bacterial microcolony counting using on-chip microscopy
Jung, Jae Hee; Lee, Jung Eun
2016-01-01
Observing microbial colonies is the standard method for determining the microbe titer and investigating the behaviors of microbes. Here, we report an automated, real-time bacterial microcolony-counting system implemented on a wide field-of-view (FOV), on-chip microscopy platform, termed ePetri. Using sub-pixel sweeping microscopy (SPSM) with a super-resolution algorithm, this system offers the ability to dynamically track individual bacterial microcolonies over a wide FOV of 5.7 mm × 4.3 mm without requiring a moving stage or lens. As a demonstration, we obtained high-resolution time-series images of S. epidermidis at 20-min intervals. We implemented an image-processing algorithm to analyze the spatiotemporal distribution of microcolonies, the development of which could be observed from a single bacterial cell. Test bacterial colonies with a minimum diameter of 20 μm could be enumerated within 6 h. We showed that our approach not only provides results that are comparable to conventional colony-counting assays but also can be used to monitor the dynamics of colony formation and growth. This microcolony-counting system using on-chip microscopy represents a new platform that substantially reduces the detection time for bacterial colony counting. It uses chip-scale image acquisition and is a simple and compact solution for the automation of colony-counting assays and microbe behavior analysis with applications in antibacterial drug discovery. PMID:26902822
Evaluating language environment analysis system performance for Chinese: a pilot study in Shanghai.
Gilkerson, Jill; Zhang, Yiwen; Xu, Dongxin; Richards, Jeffrey A; Xu, Xiaojuan; Jiang, Fan; Harnsberger, James; Topping, Keith
2015-04-01
The purpose of this study was to evaluate performance of the Language Environment Analysis (LENA) automated language-analysis system for the Chinese Shanghai dialect and Mandarin (SDM) languages. Volunteer parents of 22 children aged 3-23 months were recruited in Shanghai. Families provided daylong in-home audio recordings using LENA. A native speaker listened to 15 min of randomly selected audio samples per family to label speaker regions and provide Chinese character and SDM word counts for adult speakers. LENA segment labeling and counts were compared with rater-based values. LENA demonstrated good sensitivity in identifying adult and child; this sensitivity was comparable to that of American English validation samples. Precision was strong for adults but less so for children. LENA adult word count correlated strongly with both Chinese characters and SDM word counts. LENA conversational turn counts correlated similarly with rater-based counts after the exclusion of three unusual samples. Performance related to some degree to child age. LENA adult word count and conversational turn provided reasonably accurate estimates for SDM over the age range tested. Theoretical and practical considerations regarding LENA performance in non-English languages are discussed. Despite the pilot nature and other limitations of the study, results are promising for broader cross-linguistic applications.
NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner.
Prasad, Rameshwar; Ratib, Osman; Zaidi, Habib
2011-10-21
The objective of this study is to characterize the performance of the preclinical avalanche photodiode (APD)-based LabPET-8™ subsystem of the fully integrated trimodality PET/SPECT/CT Triumph™ scanner using the National Electrical Manufacturers Association (NEMA) NU 04-2008 protocol. The characterized performance parameters include the spatial resolution, sensitivity, scatter fraction, counts rate performance and image-quality characteristics. The PET system is fully digital using APD-based detector modules with highly integrated electronics. The detector assembly consists of phoswich pairs of Lu(1.9)Y(0.1)SiO(5) (LYSO) and Lu(0.4)Gd(1.6)SiO(5) (LGSO) crystals with dimensions of 2 × 2 × 14 mm(3) having 7.5 cm axial and 10 cm transverse field of view (FOV). The spatial resolution and sensitivity were measured using a small (22)Na point source at different positions in the scanner's FOV. The scatter fraction and count rate characteristics were measured using mouse- and rat-sized phantoms fitted with an (18)F line source. The overall imaging capabilities of the scanner were assessed using the NEMA image-quality phantom and laboratory animal studies. The NEMA-based radial and tangential spatial resolution ranged from 1.7 mm at the center of the FOV to 2.59 mm at a radial offset of 2.5 cm and from 1.85 mm at the center of the FOV to 1.76 mm at a radial offset of 2.5 cm, respectively. Iterative reconstruction improved the spatial resolution to 0.84 mm at the center of the FOV. The total absolute system sensitivity is 12.74% for an energy window of 250-650 keV. For the mouse-sized phantom, the peak noise equivalent count rate (NECR) is 183 kcps at 2.07 MBq cc(-1), whereas the peak true count rate is 320 kcps at 2.5 MBq cc(-1) with a scatter fraction of 19%. The rat-sized phantom had a scatter fraction of 31%, with a peak NECR of 67 kcps at 0.23 MBq cc(-1) and a peak true count rate of 186 kcps at 0.27 MBq cc(-1). The average activity concentration and percentage standard deviation were 126.97 kBq ml(-1) and 7%, respectively. The performance of the LabPET-8™ scanner was characterized based on the NEMA NU 04-2008 standards. The all in all performance demonstrates that the LabPET-8™ system is able to produce high-quality and highly contrasted images in a reasonable time, and as such it is well suited for preclinical molecular imaging-based research.
NEMA NU-04-based performance characteristics of the LabPET-8™ small animal PET scanner
NASA Astrophysics Data System (ADS)
Prasad, Rameshwar; Ratib, Osman; Zaidi, Habib
2011-10-01
The objective of this study is to characterize the performance of the preclinical avalanche photodiode (APD)-based LabPET-8™ subsystem of the fully integrated trimodality PET/SPECT/CT Triumph™ scanner using the National Electrical Manufacturers Association (NEMA) NU 04-2008 protocol. The characterized performance parameters include the spatial resolution, sensitivity, scatter fraction, counts rate performance and image-quality characteristics. The PET system is fully digital using APD-based detector modules with highly integrated electronics. The detector assembly consists of phoswich pairs of Lu1.9Y0.1SiO5 (LYSO) and Lu0.4Gd1.6SiO5 (LGSO) crystals with dimensions of 2 × 2 × 14 mm3 having 7.5 cm axial and 10 cm transverse field of view (FOV). The spatial resolution and sensitivity were measured using a small 22Na point source at different positions in the scanner's FOV. The scatter fraction and count rate characteristics were measured using mouse- and rat-sized phantoms fitted with an18F line source. The overall imaging capabilities of the scanner were assessed using the NEMA image-quality phantom and laboratory animal studies. The NEMA-based radial and tangential spatial resolution ranged from 1.7 mm at the center of the FOV to 2.59 mm at a radial offset of 2.5 cm and from 1.85 mm at the center of the FOV to 1.76 mm at a radial offset of 2.5 cm, respectively. Iterative reconstruction improved the spatial resolution to 0.84 mm at the center of the FOV. The total absolute system sensitivity is 12.74% for an energy window of 250-650 keV. For the mouse-sized phantom, the peak noise equivalent count rate (NECR) is 183 kcps at 2.07 MBq cc-1, whereas the peak true count rate is 320 kcps at 2.5 MBq cc-1 with a scatter fraction of 19%. The rat-sized phantom had a scatter fraction of 31%, with a peak NECR of 67 kcps at 0.23 MBq cc-1 and a peak true count rate of 186 kcps at 0.27 MBq cc-1. The average activity concentration and percentage standard deviation were 126.97 kBq ml-1 and 7%, respectively. The performance of the LabPET-8™ scanner was characterized based on the NEMA NU 04-2008 standards. The all in all performance demonstrates that the LabPET-8™ system is able to produce high-quality and highly contrasted images in a reasonable time, and as such it is well suited for preclinical molecular imaging-based research.
ERIC Educational Resources Information Center
Hart, Teresa L.; Brusseau, Timothy; Kulinna, Pamela Hodges; McClain, James J.; Tudor-Locke, Catrine
2011-01-01
This study compared step counts detected by four, low-cost, objective, physical-activity-assessment instruments and evaluated their ability to detect moderate-to-vigorous physical activity (MVPA) compared to the ActiGraph accelerometer (AG). Thirty-six 10-11-year-old children wore the NL-1000, Yamax Digiwalker SW 200, Omron HJ-151, and Walk4Life…
Grading the States. Quality Counts. Education Week. Volume 37, Number 17
ERIC Educational Resources Information Center
Education Week, 2018
2018-01-01
This 22nd edition of "Quality Counts" offers a fresh take on the annual top-to-bottom ranking of the nation's school systems on a state-by-state basis published by "Education Week". The first of three "Quality Counts" reports being rolled out over the course of the year, "Grading the States" aims to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, T; Graham, C L; Sundsmo, T
This procedure provides instructions for the calibration and use of the Canberra iSolo Low Background Alpha/Beta Counting System (iSolo) that is used for counting air filters and swipe samples. This detector is capable of providing radioisotope identification (e.g., it can discriminate between radon daughters and plutonium). This procedure includes step-by-step instructions for: (1) Performing periodic or daily 'Background' and 'Efficiency QC' checks; (2) Setting-up the iSolo for counting swipes and air filters; (3) Counting swipes and air filters for alpha and beta activity; and (4) Annual calibration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erchinger, J. L.; Orrell, John L.; Aalseth, C. E.
The Ultra-Low Background Liquid Scintillation Counter developed by Pacific Northwest National Laboratory will expand the application of liquid scintillation counting by enabling lower detection limits and smaller sample volumes. By reducing the overall count rate of the background environment approximately 2 orders of magnitude below that of commercially available systems, backgrounds on the order of tens of counts per day over an energy range of ~3–3600 keV can be realized. Finally, initial test results of the ULB LSC show promising results for ultra-low background detection with liquid scintillation counting.
Color quench correction for low level Cherenkov counting.
Tsroya, S; Pelled, O; German, U; Marco, R; Katorza, E; Alfassi, Z B
2009-05-01
The Cherenkov counting efficiency varies strongly with color quenching, thus correction curves must be used to obtain correct results. The external (152)Eu source of a Quantulus 1220 liquid scintillation counting (LSC) system was used to obtain a quench indicative parameter based on spectra area ratio. A color quench correction curve for aqueous samples containing (90)Sr/(90)Y was prepared. The main advantage of this method over the common spectra indicators is its usefulness also for low level Cherenkov counting.
A systematic assessment of goblet cell sampling of the bulbar conjunctiva by impression cytology.
Doughty, Michael J
2015-07-01
The purpose of this study was to assess the apparent goblet cell density (GCD) from conjunctival impression cytology (CIC) samples in relation to the number of conjunctival cells collected onto the filters. CIC specimens were collected from the superior-temporal bulbar conjunctiva of 16 pigmented rabbits onto Biopore (Millicell-CM) membranes, fixed with buffered glutaraldehyde and stained with Giemsa. Different numbers of microscope fields of view in each of the specimens were imaged by light microscopy using a 20× magnification objective lens (200× final magnification), and the goblet cells marked and counted. The GCD values/sq. mm were calculated. The same conjunctival region of 3 other rabbits was also prepared for transmission electron microscopy (TEM) by fixation, in situ, with the same buffered glutaraldehyde. Mean values for GCD estimates were found to vary from 399 to 1576 cells/sq. mm, depending on the image sampling and analysis strategy chosen, with the lowest inter-sample variance of around 10% being found if a maximum goblet cell count was taken on substantially multilayered regions of the CIC specimens. Counts of the number of goblet cells per 1000 visible conjunctival epithelial cells yielded a value of close to 90 (range 36-151), with modest inter-sample variability of around 30%. A three or ten 200× microscope field and random sampling strategy yielded mean GCD values between 542 and 670 cells/sq. mm, but with very high intra- and inter-sample variance of at least 60% and sometimes higher than 100%. TEM confirmed the multilayered organization of the conjunctiva and the deeper lying goblet cells. The general use of a goblet cell count as an objective marker for conjunctival normality or health is likely to be highly variable unless a more specific strategy is adopted. Beyond providing details of exactly the counting strategy used, it would be very useful to provide full details of the actual microscope field size used as well as information on the intra-sample variability in goblet cell counts. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hudson, M J; Green, A E
1980-01-01
Visual differential counts were examined for efficiency, cost effectiveness, and staff acceptability within our laboratory. A comparison with the Hemalog D system was attempted. The advantages and disadvantages of each system are enumerated and discussed in the context of a large general hospital. PMID:7440760
Conventional plating methods were used to quantify heterotrophic bacteria from a drinking water distribution system. Three media, plate count agar (PCA), R2A agar and sheep blood agar (TSA-SB) were used to determine heterotrophic plate count (HPC) levels. Grab samples were collec...
Illinois Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment
ERIC Educational Resources Information Center
Child Trends, 2010
2010-01-01
This paper presents a profile of Illinois' Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…
Automated Mobile System for Accurate Outdoor Tree Crop Enumeration Using an Uncalibrated Camera.
Nguyen, Thuy Tuong; Slaughter, David C; Hanson, Bradley D; Barber, Andrew; Freitas, Amy; Robles, Daniel; Whelan, Erin
2015-07-28
This paper demonstrates an automated computer vision system for outdoor tree crop enumeration in a seedling nursery. The complete system incorporates both hardware components (including an embedded microcontroller, an odometry encoder, and an uncalibrated digital color camera) and software algorithms (including microcontroller algorithms and the proposed algorithm for tree crop enumeration) required to obtain robust performance in a natural outdoor environment. The enumeration system uses a three-step image analysis process based upon: (1) an orthographic plant projection method integrating a perspective transform with automatic parameter estimation; (2) a plant counting method based on projection histograms; and (3) a double-counting avoidance method based on a homography transform. Experimental results demonstrate the ability to count large numbers of plants automatically with no human effort. Results show that, for tree seedlings having a height up to 40 cm and a within-row tree spacing of approximately 10 cm, the algorithms successfully estimated the number of plants with an average accuracy of 95.2% for trees within a single image and 98% for counting of the whole plant population in a large sequence of images.
Automated Mobile System for Accurate Outdoor Tree Crop Enumeration Using an Uncalibrated Camera
Nguyen, Thuy Tuong; Slaughter, David C.; Hanson, Bradley D.; Barber, Andrew; Freitas, Amy; Robles, Daniel; Whelan, Erin
2015-01-01
This paper demonstrates an automated computer vision system for outdoor tree crop enumeration in a seedling nursery. The complete system incorporates both hardware components (including an embedded microcontroller, an odometry encoder, and an uncalibrated digital color camera) and software algorithms (including microcontroller algorithms and the proposed algorithm for tree crop enumeration) required to obtain robust performance in a natural outdoor environment. The enumeration system uses a three-step image analysis process based upon: (1) an orthographic plant projection method integrating a perspective transform with automatic parameter estimation; (2) a plant counting method based on projection histograms; and (3) a double-counting avoidance method based on a homography transform. Experimental results demonstrate the ability to count large numbers of plants automatically with no human effort. Results show that, for tree seedlings having a height up to 40 cm and a within-row tree spacing of approximately 10 cm, the algorithms successfully estimated the number of plants with an average accuracy of 95.2% for trees within a single image and 98% for counting of the whole plant population in a large sequence of images. PMID:26225982
Stochastic hybrid systems for studying biochemical processes.
Singh, Abhyudai; Hespanha, João P
2010-11-13
Many protein and mRNA species occur at low molecular counts within cells, and hence are subject to large stochastic fluctuations in copy numbers over time. Development of computationally tractable frameworks for modelling stochastic fluctuations in population counts is essential to understand how noise at the cellular level affects biological function and phenotype. We show that stochastic hybrid systems (SHSs) provide a convenient framework for modelling the time evolution of population counts of different chemical species involved in a set of biochemical reactions. We illustrate recently developed techniques that allow fast computations of the statistical moments of the population count, without having to run computationally expensive Monte Carlo simulations of the biochemical reactions. Finally, we review different examples from the literature that illustrate the benefits of using SHSs for modelling biochemical processes.
Measurement of Satellite Impact Test Fragments for Modeling Orbital Debris
NASA Technical Reports Server (NTRS)
Hill, Nicole M.
2009-01-01
There are over 13,000 pieces of catalogued objects 10cm and larger in orbit around Earth [ODQN, January 2009, p12]. More than 6000 of these objects are fragments from explosions and collisions. As the earth-orbiting object count increases, debris-generating collisions in the future become a statistical inevitability. To aid in understanding this collision risk, the NASA Orbital Debris Program Office has developed computer models that calculate quantity and orbits of debris both currently in orbit and in future epochs. In order to create a reasonable computer model of the orbital debris environment, it is important to understand the mechanics of creation of debris as a result of a collision. The measurement of the physical characteristics of debris resulting from ground-based, hypervelocity impact testing aids in understanding the sizes and shapes of debris produced from potential impacts in orbit. To advance the accuracy of fragment shape/size determination, the NASA Orbital Debris Program Office recently implemented a computerized measurement system. The goal of this system is to improve knowledge and understanding of the relation between commonly used dimensions and overall shape. The technique developed involves scanning a single fragment with a hand-held laser device, measuring its size properties using a sophisticated software tool, and creating a three-dimensional computer model to demonstrate how the object might appear in orbit. This information is used to aid optical techniques in shape determination. This more automated and repeatable method provides higher accuracy in the size and shape determination of debris.
Volanis, M; Stefanakis, A; Hadjigeorgiou, I; Zoiopoulos, P
2007-06-01
The objective of this field study was to depict the extensive system of dairy sheep farming in the semi-arid environment of the island of Crete and to assess the potential margins of improvement through technical intervention. Forty-three family-run farms keeping a total of 13,870 sheep were surveyed in seven representative areas of the island. Several parameters were dealt with, concerning socio-economy, flock management and productivity. Study areas differed widely regarding feeds supplied per sheep, land cultivated for feeds, grazing land utilized and housing space. A range of parameters were recorded on flock size and their production characteristics such as births, fertility and number of lambs weaned. Milk yield and parameters associated with milk quality, such as somatic cell counts and total microbial flora, were also recorded. Technical intervention was directed towards removal of non-productive animals, programming of matings, balancing of diets, management of grazing lands and health care. Ewe fertility and numbers of lambs weaned per ewe, as well as harvested milk and milk quality (based on somatic cell counts and microbial load of milk) were also significantly improved. Information derived from this study stresses the important role of extension services to small farm sustainability and contributes to our knowledge of the dairy sheep farming systems in countries around the Mediterranean and elsewhere.
Segmentation of touching mycobacterium tuberculosis from Ziehl-Neelsen stained sputum smear images
NASA Astrophysics Data System (ADS)
Xu, Chao; Zhou, Dongxiang; Liu, Yunhui
2015-12-01
Touching Mycobacterium tuberculosis objects in the Ziehl-Neelsen stained sputum smear images present different shapes and invisible boundaries in the adhesion areas, which increases the difficulty in objects recognition and counting. In this paper, we present a segmentation method of combining the hierarchy tree analysis with gradient vector flow snake to address this problem. The skeletons of the objects are used for structure analysis based on the hierarchy tree. The gradient vector flow snake is used to estimate the object edge. Experimental results show that the single objects composing the touching objects are successfully segmented by the proposed method. This work will improve the accuracy and practicability of the computer-aided diagnosis of tuberculosis.
Honda, Harue; Gibson, Glenn R; Farmer, Sean; Keller, David; McCartney, Anne L
2011-02-01
Single-stage continuous fermentation systems were employed to examine the effects of GanedenBC(30) supplementation on the human gastrointestinal microbiota in relation to pathogen challenge in vitro. Denaturing gradient gel electrophoresis analysis demonstrated that GanedenBC(30) supplementation modified the microbial profiles in the fermentation systems compared with controls, with profiles clustering according to treatment. Overall, GanedenBC(30) supplementation did not elicit major changes in bacterial population counts in vitro, although notably higher Bcoa191 counts were seen following probiotic supplementation (compared to the controls). Pathogen challenge did not elicit significant modification of the microbial counts in vitro, although notably higher Clit135 counts were seen in the control system post-Clostridium difficile challenge than in the corresponding GanedenBC(30)-supplemented systems. Sporulation appears to be associated with the anti-microbial activity of GanedenBC(30), suggesting that a bi-modal lifecycle of GanedenBC(30)in vivo may lead to anti-microbial activity in distal regions of the gastrointestinal tract. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Trimble, Jay Phillip
2014-01-01
The Resource Prospector Mission seeks to rove the lunar surface with an in-situ resource utilization payload in search of volatiles at a polar region. The mission operations system (MOS) will need to perform the short-duration mission while taking advantage of the near real time control that the short one-way light time to the Moon provides. To maximize our use of limited resources for the design and development of the MOS we are utilizing agile and lean methods derived from our previous experience with applying these methods to software. By using methods such as "say it then sim it" we will spend less time in meetings and more time focused on the one outcome that counts - the effective utilization of our assets on the Moon to meet mission objectives.
A Review of Statistical Disclosure Control Techniques Employed by Web-Based Data Query Systems.
Matthews, Gregory J; Harel, Ofer; Aseltine, Robert H
We systematically reviewed the statistical disclosure control techniques employed for releasing aggregate data in Web-based data query systems listed in the National Association for Public Health Statistics and Information Systems (NAPHSIS). Each Web-based data query system was examined to see whether (1) it employed any type of cell suppression, (2) it used secondary cell suppression, and (3) suppressed cell counts could be calculated. No more than 30 minutes was spent on each system. Of the 35 systems reviewed, no suppression was observed in more than half (n = 18); observed counts below the threshold were observed in 2 sites; and suppressed values were recoverable in 9 sites. Six sites effectively suppressed small counts. This inquiry has revealed substantial weaknesses in the protective measures used in data query systems containing sensitive public health data. Many systems utilized no disclosure control whatsoever, and the vast majority of those that did deployed it inconsistently or inadequately.
Müller-Riemenschneider, Falk; Ng, Sheryl Hui Xian; Koh, David; Chu, Anne Hin Yee
2016-06-01
To objectively assess sedentary behavior (SB), light- and moderate-to-vigorous intensity physical activity (MVPA), and steps among Singaporean office-based workers across days of the week. A convenience sample of office-based employees of a public University was recruited. Time spent for SB, light-, and MVPA using different validated accelerometry counts per minute (CPM), and step count were determined. Depending on applied CPM for SB (less than 100, less than 150 and less than 200 CPM), 107 working adults spent between 69.2% and 76.4% of their daily wakeful time in SB. Time spent in SB and MVPA were higher on weekdays than weekends. The hourly analysis highlights patterns of greater SB during usual working hours on weekdays but not on weekends. SB at work contributes greatly toward total daily sitting time. Low PA levels and high SB levels were found on weekends.
Lazzaro, Alessandra; Corona, Arianna; Iezzi, Luca; Quaresima, Silvia; Armisi, Luca; Piccolo, Ilaria; Medaglia, Carlo Maria; Sbrenni, Sergio; Sileri, Pierpaolo; Rosato, Nicola; Gaspari, Achille Lucio; Di Lorenzo, Nicola
2017-06-01
A retained surgical item in patients (gossypiboma) is a persisting problem, despite consistent improvements and existing guidelines in counting instruments and sponges. Previous experiences with radiofrequency identification technology (RFID) tracking sponges show that it could represent an innovation, in order to reduce the criticism and increase the effectiveness during surgical procedures. We present an automated system that allows reduction of errors and improves safety in the operating room. The system consists of 3 antennas, surgical sponges containing RFID tags, and dedicated software applications, with Wi-Fi real-time communication between devices. The first antenna provides the initial count of gauzes; the second a real-time counting during surgery, including the sponges thrown into the kick-bucket; and the third can be used in the event of uneven sponge count. The software allows management at all stages of the process. In vitro and in vivo tests were performed: the system provided excellent results in detecting sponges in patients' body. Hundred percent retained sponges were detected correctly, even when they were overlapped. No false positive or false negative was recorded. The counting procedure turned out to be more streamlined and efficient and it could save time in a standard procedure. The RFID system for sponge tracking was shown to be experimentally a reliable and feasible method to track sponges with a full detection accuracy in the operating room. The results indicate the system to be safe and effective with acceptable cost-effective parameters.
Fernandes, Rafaella de Paula Paseto; Freire, Maria Teresa de Alvarenga; de Paula, Elisa Silva Maluf; Kanashiro, Ana Livea Sayuri; Catunda, Fernanda Antunes Pinto; Rosa, Alessandra Fernandes; Balieiro, Júlio Cesar de Carvalho; Trindade, Marco Antonio
2014-01-01
The aim of the present study was to evaluate the effect of different modified atmosphere packaging (MAP) systems (vacuum, 75% O2+25% CO2 and 100% CO2) on the stability of lamb loins stored at 1±1°C for 28 days. Microbiological (counts of aerobic and anaerobic psychrotrophic microorganisms, coliform at 45°C, coagulase-positive staphylococci and lactic acid bacteria and presence of Salmonella), physical and chemical (thiobarbituric acid reactive substances [TBARS], objective color, pH, water loss from cooking [WLC] and shear force), sensory (acceptance testing using a 9-point hedonic scale) and gas composition analyses were performed. Lamb meat remained stable with respect to the majority of the evaluated physical and chemical indexes and within the standards established by Brazilian legislation for pathogenic microorganisms throughout the storage period in all three packaging systems. However, with respect to psychrotrophic microorganisms, 100% CO2 packaging system provided increased stability despite presenting lower appearance preference. © 2013.
Description of a prototype emission-transmission computed tomography imaging system
NASA Technical Reports Server (NTRS)
Lang, T. F.; Hasegawa, B. H.; Liew, S. C.; Brown, J. K.; Blankespoor, S. C.; Reilly, S. M.; Gingold, E. L.; Cann, C. E.
1992-01-01
We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.
NASA Astrophysics Data System (ADS)
Xie, Dengling; Xie, Yanjun; Liu, Peng; Tong, Lieshu; Chu, Kaiqin; Smith, Zachary J.
2017-02-01
Current flow-based blood counting devices require expensive and centralized medical infrastructure and are not appropriate for field use. In this paper we report a method to count red blood cells, white blood cells as well as platelets through a low-cost and fully-automated blood counting system. The approach consists of using a compact, custom-built microscope with large field-of-view to record bright-field and fluorescence images of samples that are diluted with a single, stable reagent mixture and counted using automatic algorithms. Sample collection is performed manually using a spring loaded lancet, and volume-metering capillary tubes. The capillaries are then dropped into a tube of pre-measured reagents and gently shaken for 10-30 seconds. The sample is loaded into a measurement chamber and placed on a custom 3D printed platform. Sample translation and focusing is fully automated, and a user has only to press a button for the measurement and analysis to commence. Cost of the system is minimized through the use of custom-designed motorized components. We performed a series of comparative experiments by trained and untrained users on blood from adults and children. We compare the performance of our system, as operated by trained and untrained users, to the clinical gold standard using a Bland-Altman analysis, demonstrating good agreement of our system to the clinical standard. The system's low cost, complete automation, and good field performance indicate that it can be successfully translated for use in low-resource settings where central hematology laboratories are not accessible.
Signal to noise ratio of energy selective x-ray photon counting systems with pileup.
Alvarez, Robert E
2014-11-01
To derive fundamental limits on the effect of pulse pileup and quantum noise in photon counting detectors on the signal to noise ratio (SNR) and noise variance of energy selective x-ray imaging systems. An idealized model of the response of counting detectors to pulse pileup is used. The model assumes a nonparalyzable response and delta function pulse shape. The model is used to derive analytical formulas for the noise and energy spectrum of the recorded photons with pulse pileup. These formulas are first verified with a Monte Carlo simulation. They are then used with a method introduced in a previous paper [R. E. Alvarez, "Near optimal energy selective x-ray imaging system performance with simple detectors," Med. Phys. 37, 822-841 (2010)] to compare the signal to noise ratio with pileup to the ideal SNR with perfect energy resolution. Detectors studied include photon counting detectors with pulse height analysis (PHA), detectors that simultaneously measure the number of photons and the integrated energy (NQ detector), and conventional energy integrating and photon counting detectors. The increase in the A-vector variance with dead time is also computed and compared to the Monte Carlo results. A formula for the covariance of the NQ detector is developed. The validity of the constant covariance approximation to the Cramèr-Rao lower bound (CRLB) for larger counts is tested. The SNR becomes smaller than the conventional energy integrating detector (Q) SNR for 0.52, 0.65, and 0.78 expected number photons per dead time for counting (N), two, and four bin PHA detectors, respectively. The NQ detector SNR is always larger than the N and Q SNR but only marginally so for larger dead times. Its noise variance increases by a factor of approximately 3 and 5 for the A1 and A2 components as the dead time parameter increases from 0 to 0.8 photons per dead time. With four bin PHA data, the increase in variance is approximately 2 and 4 times. The constant covariance approximation to the CRLB is valid for larger counts such as those used in medical imaging. The SNR decreases rapidly as dead time increases. This decrease places stringent limits on allowable dead times with the high count rates required for medical imaging systems. The probability distribution of the idealized data with pileup is shown to be accurately described as a multivariate normal for expected counts greater than those typically utilized in medical imaging systems. The constant covariance approximation to the CRLB is also shown to be valid in this case. A new formula for the covariance of the NQ detector with pileup is derived and validated.
Signal to noise ratio of energy selective x-ray photon counting systems with pileup
Alvarez, Robert E.
2014-01-01
Purpose: To derive fundamental limits on the effect of pulse pileup and quantum noise in photon counting detectors on the signal to noise ratio (SNR) and noise variance of energy selective x-ray imaging systems. Methods: An idealized model of the response of counting detectors to pulse pileup is used. The model assumes a nonparalyzable response and delta function pulse shape. The model is used to derive analytical formulas for the noise and energy spectrum of the recorded photons with pulse pileup. These formulas are first verified with a Monte Carlo simulation. They are then used with a method introduced in a previous paper [R. E. Alvarez, “Near optimal energy selective x-ray imaging system performance with simple detectors,” Med. Phys. 37, 822–841 (2010)] to compare the signal to noise ratio with pileup to the ideal SNR with perfect energy resolution. Detectors studied include photon counting detectors with pulse height analysis (PHA), detectors that simultaneously measure the number of photons and the integrated energy (NQ detector), and conventional energy integrating and photon counting detectors. The increase in the A-vector variance with dead time is also computed and compared to the Monte Carlo results. A formula for the covariance of the NQ detector is developed. The validity of the constant covariance approximation to the Cramèr–Rao lower bound (CRLB) for larger counts is tested. Results: The SNR becomes smaller than the conventional energy integrating detector (Q) SNR for 0.52, 0.65, and 0.78 expected number photons per dead time for counting (N), two, and four bin PHA detectors, respectively. The NQ detector SNR is always larger than the N and Q SNR but only marginally so for larger dead times. Its noise variance increases by a factor of approximately 3 and 5 for the A1 and A2 components as the dead time parameter increases from 0 to 0.8 photons per dead time. With four bin PHA data, the increase in variance is approximately 2 and 4 times. The constant covariance approximation to the CRLB is valid for larger counts such as those used in medical imaging. Conclusions: The SNR decreases rapidly as dead time increases. This decrease places stringent limits on allowable dead times with the high count rates required for medical imaging systems. The probability distribution of the idealized data with pileup is shown to be accurately described as a multivariate normal for expected counts greater than those typically utilized in medical imaging systems. The constant covariance approximation to the CRLB is also shown to be valid in this case. A new formula for the covariance of the NQ detector with pileup is derived and validated. PMID:25370642
Nasi, Milena; De Biasi, Sara; Bianchini, Elena; Gibellini, Lara; Pinti, Marcello; Scacchetti, Tiziana; Trenti, Tommaso; Borghi, Vanni; Mussini, Cristina; Cossarizza, Andrea
2015-01-01
An accurate and affordable CD4+ T cells count is an essential tool in the fight against HIV/AIDS. Flow cytometry (FCM) is the "gold standard" for counting such cells, but this technique is expensive and requires sophisticated equipment, temperature-sensitive monoclonal antibodies (mAbs) and trained personnel. The lack of access to technical support and quality assurance programs thus limits the use of FCM in resource-constrained countries. We have tested the accuracy, the precision and the carry-over contamination of Partec CyFlow MiniPOC, a portable and economically affordable flow cytometer designed for CD4+ count and percentage, used along with the "CD4% Count Kit-Dry". Venous blood from 59 adult HIV+ patients (age: 25-58 years; 43 males and 16 females) was collected and stained with the "MiniPOC CD4% Count Kit-Dry". CD4+ count and percentage were then determined in triplicate by the CyFlow MiniPOC. In parallel, CD4 count was performed using mAbs and a CyFlow Counter, or by a dual platform system (from Beckman Coulter) based upon Cytomic FC500 ("Cytostat tetrachrome kit" for mAbs) and Coulter HmX Hematology Analyzer (for absolute cell count). The accuracy of CyFlow MiniPOC against Cytomic FC500 showed a correlation coefficient (CC) of 0.98 and 0.97 for CD4+ count and percentage, respectively. The accuracy of CyFlow MiniPOC against CyFlow Counter showed a CC of 0.99 and 0.99 for CD4 T cell count and percentage, respectively. CyFlow MiniPOC showed an excellent repeatability: CD4+ cell count and percentage were analyzed on two instruments, with an intra-assay precision below ± 5% deviation. Finally, there was no carry-over contamination for samples at all CD4 values, regardless of their position in the sequence of analysis. The cost-effective CyFlow MiniPOC produces rapid, reliable and accurate results that are fully comparable with those from highly expensive dual platform systems.
Agashiwala, Rajiv M; Louis, Elan D; Hof, Patrick R; Perl, Daniel P
2008-10-21
Non-biased systematic sampling using the principles of stereology provides accurate quantitative estimates of objects within neuroanatomic structures. However, the basic principles of stereology are not optimally suited for counting objects that selectively exist within a limited but complex and convoluted portion of the sample, such as occurs when counting cerebellar Purkinje cells. In an effort to quantify Purkinje cells in association with certain neurodegenerative disorders, we developed a new method for stereologic sampling of the cerebellar cortex, involving calculating the volume of the cerebellar tissues, identifying and isolating the Purkinje cell layer and using this information to extrapolate non-biased systematic sampling data to estimate the total number of Purkinje cells in the tissues. Using this approach, we counted Purkinje cells in the right cerebella of four human male control specimens, aged 41, 67, 70 and 84 years, and estimated the total Purkinje cell number for the four entire cerebella to be 27.03, 19.74, 20.44 and 22.03 million cells, respectively. The precision of the method is seen when comparing the density of the cells within the tissue: 266,274, 173,166, 167,603 and 183,575 cells/cm3, respectively. Prior literature documents Purkinje cell counts ranging from 14.8 to 30.5 million cells. These data demonstrate the accuracy of our approach. Our novel approach, which offers an improvement over previous methodologies, is of value for quantitative work of this nature. This approach could be applied to morphometric studies of other similarly complex tissues as well.
Agashiwala, Rajiv M.; Louis, Elan D.; Hof, Patrick R.; Perl, Daniel P.
2010-01-01
Non-biased systematic sampling using the principles of stereology provides accurate quantitative estimates of objects within neuroanatomic structures. However, the basic principles of stereology are not optimally suited for counting objects that selectively exist within a limited but complex and convoluted portion of the sample, such as occurs when counting cerebellar Purkinje cells. In an effort to quantify Purkinje cells in association with certain neurodegenerative disorders, we developed a new method for stereologic sampling of the cerebellar cortex, involving calculating the volume of the cerebellar tissues, identifying and isolating the Purkinje cell layer and using this information to extrapolate non-biased systematic sampling data to estimate the total number of Purkinje cells in the tissues. Using this approach, we counted Purkinje cells in the right cerebella of four human male control specimens, aged 41, 67, 70 and 84 years, and estimated the total Purkinje cell number for the four entire cerebella to be 27.03, 19.74, 20.44 and 22.03 million cells, respectively. The precision of the method is seen when comparing the density of the cells within the tissue: 266,274, 173,166, 167,603 and 183,575 cells/cm3, respectively. Prior literature documents Purkinje cell counts ranging from 14.8 to 30.5 million cells. These data demonstrate the accuracy of our approach. Our novel approach, which offers an improvement over previous methodologies, is of value for quantitative work of this nature. This approach could be applied to morphometric studies of other similarly complex tissues as well. PMID:18725208
Spotting East African mammals in open savannah from space.
Yang, Zheng; Wang, Tiejun; Skidmore, Andrew K; de Leeuw, Jan; Said, Mohammed Y; Freer, Jim
2014-01-01
Knowledge of population dynamics is essential for managing and conserving wildlife. Traditional methods of counting wild animals such as aerial survey or ground counts not only disturb animals, but also can be labour intensive and costly. New, commercially available very high-resolution satellite images offer great potential for accurate estimates of animal abundance over large open areas. However, little research has been conducted in the area of satellite-aided wildlife census, although computer processing speeds and image analysis algorithms have vastly improved. This paper explores the possibility of detecting large animals in the open savannah of Maasai Mara National Reserve, Kenya from very high-resolution GeoEye-1 satellite images. A hybrid image classification method was employed for this specific purpose by incorporating the advantages of both pixel-based and object-based image classification approaches. This was performed in two steps: firstly, a pixel-based image classification method, i.e., artificial neural network was applied to classify potential targets with similar spectral reflectance at pixel level; and then an object-based image classification method was used to further differentiate animal targets from the surrounding landscapes through the applications of expert knowledge. As a result, the large animals in two pilot study areas were successfully detected with an average count error of 8.2%, omission error of 6.6% and commission error of 13.7%. The results of the study show for the first time that it is feasible to perform automated detection and counting of large wild animals in open savannahs from space, and therefore provide a complementary and alternative approach to the conventional wildlife survey techniques.
SEDS1 mission software verification using a signal simulator
NASA Technical Reports Server (NTRS)
Pierson, William E.
1992-01-01
The first flight of the Small Expendable Deployer System (SEDS1) is schedule to fly as the secondary payload of a Delta 2 in March, 1993. The objective of the SEDS1 mission is to collect data to validate the concept of tethered satellite systems and to verify computer simulations used to predict their behavior. SEDS1 will deploy a 50 lb. instrumented satellite as an end mass using a 20 km tether. Langley Research Center is providing the end mass instrumentation, while the Marshall Space Flight Center is designing and building the deployer. The objective of the experiment is to test the SEDS design concept by demonstrating that the system will satisfactorily deploy the full 20 km tether without stopping prematurely, come to a smooth stop on the application of a brake, and cut the tether at the proper time after it swings to the local vertical. Also, SEDS1 will collect data which will be used to test the accuracy of tether dynamics models used to stimulate this type of deployment. The experiment will last about 1.5 hours and complete approximately 1.5 orbits. Radar tracking of the Delta II and end mass is planned. In addition, the SEDS1 on-board computer will continuously record, store, and transmit mission data over the Delta II S-band telemetry system. The Data System will count tether windings as the tether unwinds, log the times of each turn and other mission events, monitor tether tension, and record the temperature of system components. A summary of the measurements taken during the SEDS1 are shown. The Data System will also control the tether brake and cutter mechanisms. Preliminary versions of two major sections of the flight software, the data telemetry modules and the data collection modules, were developed and tested under the 1990 NASA/ASEE Summer Faculty Fellowship Program. To facilitate the debugging of these software modules, a prototype SEDS Data System was programmed to simulate turn count signals. During the 1991 summer program, the concept of simulating signals produced by the SEDS electronics systems and circuits was expanded and more precisely defined. During the 1992 summer program, the SEDS signal simulator was programmed to test the requirements of the SEDS Mission software, and this simulator will be used in the formal verification of the SEDS Mission Software. The formal test procedures specification was written which incorporates the use of the signal simulator to test the SEDS Mission Software and which incorporates procedures for testing the other major component of the SEDS software, the Monitor Software.
NASA Technical Reports Server (NTRS)
Lauer, J. L.; King, V. W.
1979-01-01
A far-infrared interferometer was converted into an emission microspectrophotometer for surface analysis. To cover the mid-infrared as well as the far-infrared the Mylar beamsplitter was made replaceable by a germanium-coated salt plate, and the Moire fringe counting system used to locate the moveable Michelson mirror was improved to read 0.5 micron of mirror displacement. Digital electronics and a dedicated minicomputer were installed for data collection and processing. The most critical element for the recording of weak emission spectra from small areas was, however, a reflecting microscope objective and phase-locked signal detection with simultaneous referencing to a blackbody source. An application of the technique to lubrication problems is shown.
Fluorescent scanning x-ray tomography with synchrotron radiation
NASA Astrophysics Data System (ADS)
Takeda, Tohoru; Maeda, Toshikazu; Yuasa, Tetsuya; Akatsuka, Takao; Ito, Tatsuo; Kishi, Kenichi; Wu, Jin; Kazama, Masahiro; Hyodo, Kazuyuki; Itai, Yuji
1995-02-01
Fluorescent scanning (FS) x-ray tomography was developed to detect nonradioactive tracer materials (iodine and gadolinium) in a living object. FS x-ray tomography consists of a silicon (111) channel cut monochromator, an x-ray shutter, an x-ray slit system and a collimator for detection, a scanning table for the target organ, and an x-ray detector with pure germanium. The minimal detectable dose of iodine in this experiment was 100 ng in a volume of 2 mm3 and a linear relationship was shown between the photon counts of a fluorescent x ray and the concentration of iodine contrast material. A FS x-ray tomographic image was clearly obtained with a phantom.
Variations in pollen counts largely explained by climate and weather
NASA Astrophysics Data System (ADS)
Jung, Stephan; Damialis, Athanasios; Estrella, Nicole; Jochner, Susanne; Menzel, Annette
2017-04-01
The interaction between climate and vegetation is well studied within phenology. Climatic / weather conditions affect e.g. flowering date, length of vegetation period, start and end of the season and the plant growth. Besides phenological stages also pollen counts can be used to investigate the interaction between climate and vegetation. Pollen emission and distribution is directly influenced by temperature, wind speed, wind direction and humidity/precipitation. The objective of this project is to study daily/sub daily variations in pollen counts of woody and herbaceous plant species along an altitudinal gradient with different climatic conditions during the vegetation period. Measurements of pollen were carried out with three volumetric pollen traps installed at the altitudes 450 m a.s.l (Freising), 700 m a.s.l (Garmisch-Partenkirchen), and 2700 m a.s.l (Schneefernerhaus near Zugspitze) representing gradient from north of Munich towards the highest mountain of Germany. Airborne pollen concentrations were recorded during the years 2014-2015. The altitudinal range of these three stations accompanied by different microclimates ("space for time approach") can be used as proxy for climate change and to assess its impact on pollen counts and thus allergenic risk for human health. For example the pollen season is shortened and pollen amount is reduced at higher sites. For detailed investigations pollen of the species Plantago, Quercus, Poaceae, Cupressaceae, Cyperacea, Betula and Platanus were chosen, because those are found in appropriate quantities. In general, pollen captured in the pollen traps to a certain extent has its origin from the immediate surrounding. Thus, it mirrors local species distribution. But furthermore the distance of pollen transport is also based on (micro-) climatic conditions, land cover and topography. The pollen trap shortly below the summit of Zugspitze (Schneefernerhaus) has an alpine environment without vegetation nearby. Therefore, this trap can be used to detect short-, middle- and long-range pollen transport. The pollen trap in Garmisch-Partenkirchen is located in the valley below Zugspitze making these two stations suitable for a direct comparison. First results show that the total amount of pollen at Schneefernerhaus for Plantago, Quercus, Poaceae, Cupressaceae, Cyperaceae and Betula is only about 20% in comparison to Garmisch. Furthermore there are daily differences in the pollen counts in yearly sum between morning (24:00 -12:00) and afternoon (12:00- 24:00). This phenomenon might be caused by diurnal climatic variations in the boundary layer as well as local mountain wind systems (changing wind direction from morning to afternoon time). Additionally pollen counts were linked to weather data recorded by the German Meteorological Service and local climate stations. Results indicate that the duration of precipitation events is a major factor of influence concerning the counted pollen. With increasing duration of a rain event pollen counts are decreasing.
2011-01-01
Background Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Methods Pregnant women (n = 58) with body mass index ≥25 kg/m2 at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Results Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Conclusions Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women. PMID:21703033
A Bayesian Method for Identifying Contaminated Detectors in Low-Level Alpha Spectrometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maclellan, Jay A.; Strom, Daniel J.; Joyce, Kevin E.
2011-11-02
Analyses used for radiobioassay and other radiochemical tests are normally designed to meet specified quality objectives, such relative bias, precision, and minimum detectable activity (MDA). In the case of radiobioassay analyses for alpha emitting radionuclides, a major determiner of the process MDA is the instrument background. Alpha spectrometry detectors are often restricted to only a few counts over multi-day periods in order to meet required MDAs for nuclides such as plutonium-239 and americium-241. A detector background criterion is often set empirically based on experience, or frequentist or classical statistics are applied to the calculated background count necessary to meet amore » required MDA. An acceptance criterion for the detector background is set at the multiple of the estimated background standard deviation above the assumed mean that provides an acceptably small probability of observation if the mean and standard deviation estimate are correct. The major problem with this method is that the observed background counts used to estimate the mean, and thereby the standard deviation when a Poisson distribution is assumed, are often in the range of zero to three counts. At those expected count levels it is impossible to obtain a good estimate of the true mean from a single measurement. As an alternative, Bayesian statistical methods allow calculation of the expected detector background count distribution based on historical counts from new, uncontaminated detectors. This distribution can then be used to identify detectors showing an increased probability of contamination. The effect of varying the assumed range of background counts (i.e., the prior probability distribution) from new, uncontaminated detectors will be is discussed.« less
Food insecurity and low CD4 count among HIV-infected people: a systematic review and meta-analysis.
Aibibula, Wusiman; Cox, Joseph; Hamelin, Anne-Marie; Mamiya, Hiroshi; Klein, Marina B; Brassard, Paul
2016-12-01
Food insecurity is defined as a limited or uncertain ability to acquire acceptable foods in socially acceptable ways, or limited or uncertain availability of nutritionally adequate and safe foods. While effective antiretroviral treatment can significantly increase CD4 counts in the majority of patients, there are certain populations who remain at relatively low CD4 count levels. Factors possibly associated with poor CD4 recovery have been extensively studied, but the association between food insecurity and low CD4 count is inconsistent in the literature. The objective is to systematically review published literature to determine the association between food insecurity and CD4 count among HIV-infected people. PubMed, Web of Science, ProQuest ABI/INFORM Complete, Ovid Medline and EMBASE Classic, plus bibliographies of relevant studies were systematically searched up to May 2015, where the earliest database coverage started from 1900. Studies that quantitatively assessed the association between food insecurity and CD4 count among HIV-infected people were eligible for inclusion. Study results were summarized using random effects model. A total of 2093 articles were identified through electronic database search and manual bibliographic search, of which 8 studies included in this meta-analysis. Food insecure people had 1.32 times greater odds of having lower CD4 counts compared to food secure people (OR = 1.32, 95% CI: 1.15-1.53) and food insecure people had on average 91 fewer CD4 cells/µl compared to their food secure counterparts (mean difference = -91.09, 95% CI: -156.16, -26.02). Food insecurity could be a potential barrier to immune recovery as measured by CD4 counts among HIV-infected people.
Hino, Kimihiro; Lee, Jung Su; Asami, Yasushi
2017-12-01
People's year-round interpersonal step count variations according to meteorological conditions are not fully understood, because complete year-round data from a sufficient sample of the general population are difficult to acquire. This study examined the associations between meteorological conditions and objectively measured step counts using year-round data collected from a large cohort ( N = 24,625) in Yokohama, Japan from April 2015 to March 2016. Two-piece linear regression analysis was used to examine the associations between the monthly median daily step count and three meteorological indices (mean values of temperature, temperature-humidity index (THI), and net effective temperature (NET)). The number of steps per day peaked at temperatures between 19.4 and 20.7 °C. At lower temperatures, the increase in steps per day was between 46.4 and 52.5 steps per 1 °C increase. At temperatures higher than those at which step counts peaked, the decrease in steps per day was between 98.0 and 187.9 per 1 °C increase. Furthermore, these effects were more obvious in elderly than non-elderly persons in both sexes. A similar tendency was seen when using THI and NET instead of temperature. Among the three meteorological indices, the highest R 2 value with step counts was observed with THI in all four groups. Both high and low meteorological indices discourage people from walking and higher values of the indices adversely affect step count more than lower values, particularly among the elderly. Among the three indices assessed, THI best explains the seasonal fluctuations in step counts.
Development of a rapid optic bacteria detecting system based on ATP bioluminescence
NASA Astrophysics Data System (ADS)
Liu, Jun Tao; Luo, JinPing; Liu, XiaoHong; Cai, XinXia
2014-12-01
A rapid optic bacteria detecting system based on the principle of Adenosine triphosphate(ATP) bioluminescence was presented in this paper. This system consisted of bioluminescence-based biosensor and the high-sensitivity optic meter. A photon counting photomultiplier tube (PMT) module was used to improve the detection sensitivity, and a NIOS II/f processor based on a Field Programmable Gate Array(FPGA) was used to control the system. In this work, Micrococcus luteus were chosen as the test sample. Several Micrococcus luteus suspension with different concentration was tested by both T2011 and plate counting method. By comparing the two group results, an calibration curve was obtained from the bioluminescence intensity for Micrococcus luteus in the range of 2.3×102 ~ 2.3×106 CFU/mL with a good correlation coefficient of 0.960. An impacting Air microorganism sampler was used to capture Airborne Bacteria, and 8 samples were collected in different place. The TBC results of 8 samples by T2011 were between 10 ~ 2×103 cfu/mL, consistent with that of plate counting method, which indicated that 8 samples were between 10 ~ 3×103 cfu/mL. For total airborne bacteria count was small, correlation coefficient was poor. Also no significant difference was found between T2011 and plate counting method by statistical analyses.
Study on ultra-fast single photon counting spectrometer based on PCI
NASA Astrophysics Data System (ADS)
Zhang, Xi-feng
2010-10-01
The time-correlated single photon counting spectrometer developed uses PCI bus technology. We developed the ultrafast data acquisition card based on PCI, replace multi-channel analyzer primary. The system theory and design of the spectrometer are presented in detail, and the process of operation is introduced with the integration of the system. Many standard samples have been measured and the data have been analyzed and contrasted. Experimental results show that the spectrometer, s sensitive is single photon counting, and fluorescence life-span and time resolution is picosecond level. And the instrument could measure time-resolved spectroscopy.
Crane, Thomas W.
1986-01-01
The disclosure is directed to an apparatus and method for determining the content and distribution of a thermal neutron absorbing material within an object. Neutrons having an energy higher than thermal neutrons are generated and thermalized. The thermal neutrons are detected and counted. The object is placed between the neutron generator and the neutron detector. The reduction in the neutron flux corresponds to the amount of thermal neutron absorbing material in the object. The object is advanced past the neutron generator and neutron detector to obtain neutron flux data for each segment of the object. The object may comprise a space reactor heat pipe and the thermal neutron absorbing material may comprise lithium.
Crane, T.W.
1983-12-21
The disclosure is directed to an apparatus and method for determining the content and distribution of a thermal neutron absorbing material within an object. Neutrons having an energy higher than thermal neutrons are generated and thermalized. The thermal neutrons are detected and counted. The object is placed between the neutron generator and the neutron detector. The reduction in the neutron flux corresponds to the amount of thermal neutron absorbing material in the object. The object is advanced past the neutron generator and neutron detector to obtain neutron flux data for each segment of the object. The object may comprise a space reactor heat pipe and the thermal neutron absorbing material may comprise lithium.
Laser-induced photo emission detection: data acquisition based on light intensity counting
NASA Astrophysics Data System (ADS)
Yulianto, N.; Yudasari, N.; Putri, K. Y.
2017-04-01
Laser Induced Breakdown Detection (LIBD) is one of the quantification techniques for colloids. There are two ways of detection in LIBD: optical detection and acoustic detection. LIBD is based on the detection of plasma emission due to the interaction between particle and laser beam. In this research, the changing of light intensity during plasma formations was detected by a photodiode sensor. A photo emission data acquisition system was built to collect and transform them into digital counts. The real-time system used data acquisition device National Instrument DAQ 6009 and LABVIEW software. The system has been tested on distilled water and tap water samples. The result showed 99.8% accuracy by using counting technique in comparison to the acoustic detection with sample rate of 10 Hz, thus the acquisition system can be applied as an alternative method to the existing LIBD acquisition system.