Sample records for objective biomechanical measures

  1. Biomechanical Assessment of the Canadian Integrated Load Carriage System using Objective Assessment Measures

    DTIC Science & Technology

    2001-05-01

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADPO 11004 TITLE: Biomechanical Assessment of the Canadian Integrated Load...ADP010987 thru ADPO11009 UNCLASSIFIED 21-1 Biomechanical Assessment of the Canadian Integrated Load Carriage System using Objective Assessment Measures Joan...CANADA, B3J 2X4 Summary The purpose of this study was to provide an overview of contributions by biomechanical testing to the design of the final

  2. Single-beam, dual-view digital holographic interferometry for biomechanical strain measurements of biological objects

    NASA Astrophysics Data System (ADS)

    Pantelić, Dejan V.; Grujić, Dušan Ž.; Vasiljević, Darko M.

    2014-12-01

    We describe a method for dual-view biomechanical strain measurements of highly asymmetrical biological objects, like teeth or bones. By using a spherical mirror, we were able to simultaneously record a digital hologram of the object itself and the mirror image of its (otherwise invisible) rear side. A single laser beam was sufficient to illuminate both sides of the object, and to provide a reference beam. As a result, the system was mechanically very stable, enabling long exposure times (up to 2 min) without the need for vibration isolation. The setup is simple to construct and adjust, and can be used to interferometrically observe any object that is smaller than the mirror diameter. Parallel data processing on a CUDA-enabled (compute unified device architecture) graphics card was used to reconstruct digital holograms and to further correct image distortion. We used the setup to measure the deformation of a tooth due to mastication forces. The finite-element method was used to compare experimental results and theoretical predictions.

  3. Single-beam, dual-view digital holographic interferometry for biomechanical strain measurements of biological objects.

    PubMed

    Pantelić, Dejan V; Grujić, Dušan Ž; Vasiljević, Darko M

    2014-12-01

    We describe a method for dual-view biomechanical strain measurements of highly asymmetrical biological objects, like teeth or bones. By using a spherical mirror, we were able to simultaneously record a digital hologram of the object itself and the mirror image of its (otherwise invisible) rear side. A single laser beam was sufficient to illuminate both sides of the object, and to provide a reference beam. As a result, the system was mechanically very stable, enabling long exposure times (up to 2 min) without the need for vibration isolation. The setup is simple to construct and adjust, and can be used to interferometrically observe any object that is smaller than the mirror diameter. Parallel data processing on a CUDA-enabled (compute unified device architecture) graphics card was used to reconstruct digital holograms and to further correct image distortion. We used the setup to measure the deformation of a tooth due to mastication forces. The finite-element method was used to compare experimental results and theoretical predictions.

  4. Conceptual framework on the application of biomechanical measurement methods in driving behavior study

    NASA Astrophysics Data System (ADS)

    Sanjaya, Kadek Heri; Sya'bana, Yukhi Mustaqim Kusuma

    2017-01-01

    Research on eco-friendly vehicle development in Indonesia has largely neglected ergonomic study, despite the fact that traffic accidents have resulted in greater economic cost than fuel subsidy. We have performed a biomechanical experiment on human locomotion earlier. In this article, we describe the importance of implementing the biomechanical measurement methods in transportation ergonomic study. The instruments such as electromyogram (EMG), load cell, pressure sensor, and motion analysis methods as well as cross-correlation function analysis were explained, then the possibility of their application in driving behavior study is described. We describe the potentials and challenges of the biomechanical methods concerning the future vehicle development. The methods provide greater advantages in objective and accurate measurement not only in human task performance but also its correlation with vehicle performance.

  5. Biomechanical patterns of text-message distraction.

    PubMed

    Le, Peter; Hwang, Jaejin; Grawe, Sarah; Li, Jing; Snyder, Alison; Lee, Christina; Marras, William S

    2015-01-01

    The objective of this study was to identify biomechanical measures that can distinguish texting distraction in a laboratory-simulated driving environment. The goal would be to use this information to provide an intervention for risky driving behaviour. Sixteen subjects participated in this study. Three independent variables were tested: task (texting, visual targeting, weighted and non-weighted movements), task direction (front and side) and task distance (close and far). Dependent variables consisted of biomechanical moments, head displacement and the length of time to complete each task. Results revealed that the time to complete each task was higher for texting compared to other tasks. Peak moments during texting were only distinguishable from visual targeting. Peak head displacement and cumulative biomechanical exposure measures indicated that texting can be distinguished from other tasks. Therefore, it may be useful to take into account both temporal and biomechanical measures when considering warning systems to detect texting distraction.

  6. Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers

    PubMed Central

    Koontz, Alicia M.; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L.; Cooper, Rory A.

    2017-01-01

    This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 non-disabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers. We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies. PMID:22068376

  7. Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers.

    PubMed

    Koontz, Alicia M; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L; Cooper, Rory A

    2011-01-01

    This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.

  8. [Evaluation of corneal biomechanics in keratoconus using dynamic ultra-high-speed Scheimpflug measurements].

    PubMed

    Brettl, S; Franko Zeitz, P; Fuchsluger, T A

    2018-06-22

    The in vivo analysis of corneal biomechanics in patients with keratoconus is especially of interest with respect to diagnosis, follow-up and monitoring of the disease. For a better understanding it is necessary to describe the potential of dynamic Scheimpflug measurements for the detection and interpretation of biomechanical changes in keratoconus. The current state of analyzing biomechanical changes in keratoconus with the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) is described. This technique represents a new approach for understanding corneal biomechanics. Furthermore, it was investigated whether the device can biomechanically quantify a rigidity increasing effect of therapeutic UV-crosslinking and whether early stages of keratoconus can be detected using dynamic Scheimpflug analysis. In patients with keratoconus, the in vivo analysis of corneal biomechanics using dynamic Scheimpflug measurements as a supplementary procedure can be of advantage with respect to disease management. By optimization of screening of subclinical keratoconus stages, this method widens the analytic spectrum regarding diagnosis and follow-up of the disease; however, further studies are required to evaluate whether visual outcome of affected patients can be improved by earlier diagnosis.

  9. Biomechanical and Hemodynamic Measures of Right Ventricular Diastolic Function: Translating Tissue Biomechanics to Clinical Relevance.

    PubMed

    Jang, Sae; Vanderpool, Rebecca R; Avazmohammadi, Reza; Lapshin, Eugene; Bachman, Timothy N; Sacks, Michael; Simon, Marc A

    2017-09-12

    Right ventricular (RV) diastolic function has been associated with outcomes for patients with pulmonary hypertension; however, the relationship between biomechanics and hemodynamics in the right ventricle has not been studied. Rat models of RV pressure overload were obtained via pulmonary artery banding (PAB; control, n=7; PAB, n=5). At 3 weeks after banding, RV hemodynamics were measured using a conductance catheter. Biaxial mechanical properties of the RV free wall myocardium were obtained to extrapolate longitudinal and circumferential elastic modulus in low and high strain regions (E 1 and E 2 , respectively). Hemodynamic analysis revealed significantly increased end-diastolic elastance (E ed ) in PAB (control: 55.1 mm Hg/mL [interquartile range: 44.7-85.4 mm Hg/mL]; PAB: 146.6 mm Hg/mL [interquartile range: 105.8-155.0 mm Hg/mL]; P =0.010). Longitudinal E 1 was increased in PAB (control: 7.2 kPa [interquartile range: 6.7-18.1 kPa]; PAB: 34.2 kPa [interquartile range: 18.1-44.6 kPa]; P =0.018), whereas there were no significant changes in longitudinal E 2 or circumferential E 1 and E 2 . Last, wall stress was calculated from hemodynamic data by modeling the right ventricle as a sphere: stress=Pressure×radius2×thickness. RV pressure overload in PAB rats resulted in an increase in diastolic myocardial stiffness reflected both hemodynamically, by an increase in E ed , and biomechanically, by an increase in longitudinal E 1 . Modest increases in tissue biomechanical stiffness are associated with large increases in E ed . Hemodynamic measurements of RV diastolic function can be used to predict biomechanical changes in the myocardium. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  10. Biomechanical measures of knee joint mobilization.

    PubMed

    Silvernail, Jason L; Gill, Norman W; Teyhen, Deydre S; Allison, Stephen C

    2011-08-01

    The purpose of this study was to quantify the biomechanical properties of specific manual therapy techniques in patients with symptomatic knee osteoarthritis. Twenty subjects (7 female/13 male, age 54±8 years, ht 1·7±0·1 m, wt 94·2±21·8 kg) participated in this study. One physical therapist delivered joint mobilizations (tibiofemoral extension and flexion; patellofemoral medial-lateral and inferior glide) at two grades (Maitland's grade III and grade IV). A capacitance-based pressure mat was used to capture biomechanical characteristics of force and frequency during 2 trials of 15 second mobilizations. Statistical analysis included intraclass correlation coefficient (ICC(3,1)) for intrarater reliability and 2×4 repeated measures analyses of variance and post-hoc comparison tests. Force (Newtons) measurements (mean, max.) for grade III were: extension 45, 74; flexion 39, 61; medial-lateral glide 20, 34; inferior glide 16, 27. Force (Newtons) measurements (mean, max.) for grade IV were: extension 57, 76; flexion 47, 68; medial-lateral glide 23, 36; inferior glide 18, 35. Frequency (Hz) measurements were between 0·9 and 1·2 for grade III, and between 2·1 and 2·4 for grade IV. ICCs were above 0·90 for almost all measures. Maximum force measures were between the ranges reported for cervical and lumbar mobilization at similar grades. Mean force measures were greater at grade IV than III. Oscillation frequency and peak-to-peak amplitude measures were consistent with the grade performed (i.e. greater frequency at grade IV, greater peak-to-peak amplitude at grade III). Intrarater reliability for force, peak-to-peak amplitude and oscillation frequency for knee joint mobilizations was excellent.

  11. Biomechanical measures of knee joint mobilization

    PubMed Central

    Silvernail, Jason L; Gill, Norman W; Teyhen, Deydre S; Allison, Stephen C

    2011-01-01

    Background and purpose The purpose of this study was to quantify the biomechanical properties of specific manual therapy techniques in patients with symptomatic knee osteoarthritis. Methods Twenty subjects (7 female/13 male, age 54±8 years, ht 1·7±0·1 m, wt 94·2±21·8 kg) participated in this study. One physical therapist delivered joint mobilizations (tibiofemoral extension and flexion; patellofemoral medial–lateral and inferior glide) at two grades (Maitland’s grade III and grade IV). A capacitance-based pressure mat was used to capture biomechanical characteristics of force and frequency during 2 trials of 15 second mobilizations. Statistical analysis included intraclass correlation coefficient (ICC3,1) for intrarater reliability and 2×4 repeated measures analyses of variance and post-hoc comparison tests. Results Force (Newtons) measurements (mean, max.) for grade III were: extension 45, 74; flexion 39, 61; medial–lateral glide 20, 34; inferior glide 16, 27. Force (Newtons) measurements (mean, max.) for grade IV were: extension 57, 76; flexion 47, 68; medial–lateral glide 23, 36; inferior glide 18, 35. Frequency (Hz) measurements were between 0·9 and 1·2 for grade III, and between 2·1 and 2·4 for grade IV. ICCs were above 0·90 for almost all measures. Discussion and conclusion Maximum force measures were between the ranges reported for cervical and lumbar mobilization at similar grades. Mean force measures were greater at grade IV than III. Oscillation frequency and peak-to-peak amplitude measures were consistent with the grade performed (i.e. greater frequency at grade IV, greater peak-to-peak amplitude at grade III). Intrarater reliability for force, peak-to-peak amplitude and oscillation frequency for knee joint mobilizations was excellent. PMID:22851879

  12. Corneal biomechanical properties in different ocular conditions and new measurement techniques.

    PubMed

    Garcia-Porta, Nery; Fernandes, Paulo; Queiros, Antonio; Salgado-Borges, Jose; Parafita-Mato, Manuel; González-Méijome, Jose Manuel

    2014-01-01

    Several refractive and therapeutic treatments as well as several ocular or systemic diseases might induce changes in the mechanical resistance of the cornea. Furthermore, intraocular pressure measurement, one of the most used clinical tools, is also highly dependent on this characteristic. Corneal biomechanical properties can be measured now in the clinical setting with different instruments. In the present work, we review the potential role of the biomechanical properties of the cornea in different fields of ophthalmology and visual science in light of the definitions of the fundamental properties of matter and the results obtained from the different instruments available. The body of literature published so far provides an insight into how the corneal mechanical properties change in different sight-threatening ocular conditions and after different surgical procedures. The future in this field is very promising with several new technologies being applied to the analysis of the corneal biomechanical properties.

  13. Corneal Biomechanical Properties in Different Ocular Conditions and New Measurement Techniques

    PubMed Central

    Garcia-Porta, Nery; Salgado-Borges, Jose; Parafita-Mato, Manuel; González-Méijome, Jose Manuel

    2014-01-01

    Several refractive and therapeutic treatments as well as several ocular or systemic diseases might induce changes in the mechanical resistance of the cornea. Furthermore, intraocular pressure measurement, one of the most used clinical tools, is also highly dependent on this characteristic. Corneal biomechanical properties can be measured now in the clinical setting with different instruments. In the present work, we review the potential role of the biomechanical properties of the cornea in different fields of ophthalmology and visual science in light of the definitions of the fundamental properties of matter and the results obtained from the different instruments available. The body of literature published so far provides an insight into how the corneal mechanical properties change in different sight-threatening ocular conditions and after different surgical procedures. The future in this field is very promising with several new technologies being applied to the analysis of the corneal biomechanical properties. PMID:24729900

  14. Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device

    PubMed Central

    Modis, Laszlo; Hassan, Ziad; Szalai, Eszter; Flaskó, Zsuzsanna; Berta, Andras; Nemeth, Gabor

    2016-01-01

    AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43±21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41±40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty. PMID:26949641

  15. Biomechanically determined hand force limits protecting the low back during occupational pushing and pulling tasks.

    PubMed

    Weston, Eric B; Aurand, Alexander; Dufour, Jonathan S; Knapik, Gregory G; Marras, William S

    2018-06-01

    Though biomechanically determined guidelines exist for lifting, existing recommendations for pushing and pulling were developed using a psychophysical approach. The current study aimed to establish objective hand force limits based on the results of a biomechanical assessment of the forces on the lumbar spine during occupational pushing and pulling activities. Sixty-two subjects performed pushing and pulling tasks in a laboratory setting. An electromyography-assisted biomechanical model estimated spinal loads, while hand force and turning torque were measured via hand transducers. Mixed modelling techniques correlated spinal load with hand force or torque throughout a wide range of exposures in order to develop biomechanically determined hand force and torque limits. Exertion type, exertion direction, handle height and their interactions significantly influenced dependent measures of spinal load, hand force and turning torque. The biomechanically determined guidelines presented herein are up to 30% lower than comparable psychophysically derived limits and particularly more protective for straight pushing. Practitioner Summary: This study utilises a biomechanical model to develop objective biomechanically determined push/pull risk limits assessed via hand forces and turning torque. These limits can be up to 30% lower than existing psychophysically determined pushing and pulling recommendations. Practitioners should consider implementing these guidelines in both risk assessment and workplace design moving forward.

  16. A systematic review of objective burn scar measurements.

    PubMed

    Lee, Kwang Chear; Dretzke, Janine; Grover, Liam; Logan, Ann; Moiemen, Naiem

    2016-01-01

    Problematic scarring remains a challenging aspect to address in the treatment of burns and can significantly affect the quality of life of the burn survivor. At present, there are few treatments available in the clinic to control adverse scarring, but experimental pharmacological anti-scarring strategies are now beginning to emerge. Their comparative success must be based on objective measurements of scarring, yet currently the clinical assessment of scars is not carried out systematically and is mostly based on subjective review of patients. However, several techniques and devices are being introduced that allow objective analysis of the burn scar. The aim of this article is to evaluate various objective measurement tools currently available and recommend a useful panel that is suitable for use in clinical trials of anti-scarring therapies. A systematic literature search was done using the Web of Science, PubMed and Cochrane databases. The identified devices were then classified and grouped according to the parameters they measured. The tools were then compared and assessed in terms of inter- and intra-rater reproducibility, ease of use and cost. After duplicates were removed, 5062 articles were obtained in the search. After further screening, 157 articles which utilised objective burn scar measurement systems or tools were obtained. The scar measurement devices can be broadly classified into those measuring colour, metric variables, texture, biomechanical properties and pathophysiological disturbances. Objective scar measurement tools allow the accurate and reproducible evaluation of scars, which is important for both clinical and scientific use. However, studies to evaluate their relative performance and merits of these tools are scarce, and there remain factors, such as itch and pain, which cannot be measured objectively. On reviewing the available evidence, a panel of devices for objective scar measurement is recommended consisting of the 3D cameras (Eykona

  17. Laser Metrology In Biomechanics

    NASA Astrophysics Data System (ADS)

    Pryputniewicz, Ryszard J.

    1983-12-01

    Modern treatment of sceletal disharmonies and malocclusions utilizes application of external forces. In order to effectively use these therapeutic forces, knowledge of three-dimensional displacements of bones with correlation to biological changes is required. In the past, this problem has been studied in a number of ways using, for example, strain gauges, brittle coatings, photoelasticity, as well as clinical observations and mathematical modeling. Becouse of their inherent limitations, these techniques did not always provide all the information necessary for development of meaningful relationships between the applied force system and the resulting biological remodeling. However, recent advances in the field of la-ser metrology allowed to overcome some of the dificulties found in the earlier methods and permitted development of new techniques for non-invasive measurements of bone motions in three-dimensional space. These laser techniques are particularly useful in biomechanics because they provide for rapid and accurate determination of displacements over the entire surface of the investigate object. In this paper, application of laser techniques for quantitative in-vivo and in-vitro measurements in biomechanics will be discussed and illustrated with representative examples.

  18. From conventional sensors to fibre optic sensors for strain and force measurements in biomechanics applications: a review.

    PubMed

    Roriz, Paulo; Carvalho, Lídia; Frazão, Orlando; Santos, José Luís; Simões, José António

    2014-04-11

    In vivo measurement, not only in animals but also in humans, is a demanding task and is the ultimate goal in experimental biomechanics. For that purpose, measurements in vivo must be performed, under physiological conditions, to obtain a database and contribute for the development of analytical models, used to describe human biomechanics. The knowledge and control of the mechanisms involved in biomechanics will allow the optimization of the performance in different topics like in clinical procedures and rehabilitation, medical devices and sports, among others. Strain gages were first applied to bone in a live animal in 40's and in 80's for the first time were applied fibre optic sensors to perform in vivo measurements of Achilles tendon forces in man. Fibre optic sensors proven to have advantages compare to conventional sensors and a great potential for biomechanical and biomedical applications. Compared to them, they are smaller, easier to implement, minimally invasive, with lower risk of infection, highly accurate, well correlated, inexpensive and multiplexable. The aim of this review article is to give an overview about the evolution of the experimental techniques applied in biomechanics, from conventional to fibre optic sensors. In the next sections the most relevant contributions of these sensors, for strain and force in biomechanical applications, will be presented. Emphasis was given to report of in vivo experiments and clinical applications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. A comparison of four office chairs using biomechanical measures.

    PubMed

    Bush, Tamara Reid; Hubbard, Robert P

    2008-08-01

    The authors sought to use biomechanical measures, including motion and pressure, to compare four office chairs. The fit of a person to a chair is related to the geometric and kinematic compatibility between the two. This geometric compatibility influences the motions that are allowed or prohibited and the support pressures at the body-chair interface. Thus, during evaluation, it is necessary to treat the chair and user as a system. Four dynamic test conditions were evaluated with 14 participants of varying anthropometries. Test conditions were selected to compare the ability to accommodate primary and secondary motions (recline and spinal articulation) of seated occupants. The ability of a chair to allow recline, yet maintain head and hand positions, was compared across chairs. Also, the ability of each chair to allow and support spinal articulation was evaluated. Motion data for the chair, head, thorax, pelvis, and extremities were collected along with chair back pressures. Upon completion of testing, subjective assessments were also conducted. Statistically significant differences were found between chairs relative to head and hand motions. Also, significant differences were noted for the chairs' ability to move with the body during spinal articulation and the ability to provide support. Subjective assessments also yielded differences. Biomechanical analyses using motions and pressures can be conducted on office chairs with significant differences detected in their performance. Biomechanical assessments can be used to compare and contrast office chairs in terms that are relatable to fatigue reduction as well as operator performance.

  20. The Undergraduate Biomechanics Experience at Iowa State University.

    ERIC Educational Resources Information Center

    Francis, Peter R.

    This paper discusses the objectives of a program in biomechanics--the analysis of sports skills and movement--and the evolution of the biomechanics program at Iowa State University. The primary objective of such a course is to provide the student with the basic tools necessary for adequate analysis of human movement, with special emphasis upon…

  1. Developmental biomechanics of the human cervical spine.

    PubMed

    Nuckley, David J; Linders, David R; Ching, Randal P

    2013-04-05

    Head and neck injuries, the leading cause of death for children in the U.S., are difficult to diagnose, treat, and prevent because of a critical void in our understanding of the biomechanical response of the immature cervical spine. The objective of this study was to investigate the functional and failure biomechanics of the cervical spine across multiple axes of loading throughout maturation. A correlational study design was used to examine the relationships governing spinal maturation and biomechanical flexibility curves and tolerance data using a cadaver human in vitro model. Eleven human cadaver cervical spines from across the developmental spectrum (2-28 years) were dissected into segments (C1-C2, C3-C5, and C6-C7) for biomechanical testing. Non-destructive flexibility tests were performed in tension, compression, flexion, extension, lateral bending, and axial rotation. After measuring their intact biomechanical responses, each segment group was failed in different modes to measure the tissue tolerance in tension (C1-C2), compression (C3-C5), and extension (C5-C6). Classical injury patterns were observed in all of the specimens tested. Both the functional (p<0.014) and failure (p<0.0001) mechanics exhibited significant relationships with age. Nonlinear flexibility curves described the functional response of the cervical spine throughout maturation and elucidated age, spinal level, and mode of loading specificity. These data support our understanding of the child cervical spine from a developmental perspective and facilitate the generation of injury prevention or management schema for the mitigation of child spine injuries and their deleterious effects. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Biomechanics as a window into the neural control of movement

    PubMed Central

    2016-01-01

    Abstract Biomechanics and motor control are discussed as parts of a more general science, physics of living systems. Major problems of biomechanics deal with exact definition of variables and their experimental measurement. In motor control, major problems are associated with formulating currently unknown laws of nature specific for movements by biological objects. Mechanics-based hypotheses in motor control, such as those originating from notions of a generalized motor program and internal models, are non-physical. The famous problem of motor redundancy is wrongly formulated; it has to be replaced by the principle of abundance, which does not pose computational problems for the central nervous system. Biomechanical methods play a central role in motor control studies. This is illustrated with studies with the reconstruction of hypothetical control variables and those exploring motor synergies within the framework of the uncontrolled manifold hypothesis. Biomechanics and motor control have to merge into physics of living systems, and the earlier this process starts the better. PMID:28149390

  3. Animation of in vitro biomechanical tests.

    PubMed

    Cripton, P A; Sati, M; Orr, T E; Bourquin, Y; Dumas, G A; Nolte, L P

    2001-08-01

    Interdisciplinary communication of three-dimensional kinematic data arising from in vitro biomechanical tests is challenging. Complex kinematic representations such as the helical axes of motion (HAM) add to the challenge. The difficulty increases further when other quantities (i.e. load or tissue strain data) are combined with the kinematic data. The objectives of this study were to develop a method to graphically replay and animate in vitro biomechanical tests including HAM data. This will allow intuitive interpretation of kinematic and other data independent of the viewer's area of expertise. The value of this method was verified with a biomechanical test investigating load-sharing of the cervical spine. Three 3.0 mm aluminium spheres were glued to each of the two vertebrae from a C2-3 segment of a human cervical spine. Before the biomechanical tests, CT scans were made of the specimen (slice thickness=1.0 mm and slice spacing=1.5 mm). The specimens were subjected to right axial torsion moments (2.0 Nm). Strain rosettes mounted to the anterior surface of the C3 vertebral body and bilaterally beneath the facet joints on C3 were used to estimate the force flow through the specimen. The locations of the aluminium spheres were digitised using a space pointer and the motion analysis system. Kinematics were measured using an optoelectronic motion analysis system. HAMs were calculated to describe the specimen kinematics. The digitised aluminium sphere locations were used to match the CT and biomechanical test data (RMS errors between the CT and experimental points were less than 1.0 mm). The biomechanical tests were "replayed" by animating reconstructed CT models in accordance with the recorded experimental kinematics, using custom software. The animated test replays allowed intuitive analysis of the kinematic data in relation to the strain data. This technique improves the ability of experts from disparate backgrounds to interpret and discuss this type of

  4. Importance of accurately assessing biomechanics of the cornea.

    PubMed

    Roberts, Cynthia J

    2016-07-01

    This article summarizes the state-of-the-art in clinical corneal biomechanics, including procedures in which biomechanics play a role, and the clinical consequences in terms of error in estimating intraocular pressure (IOP). Corneal biomechanical response to refractive surgery can be categorized into either stable alteration of surface shape and thus visual outcome, or unstable biomechanical decompensation. The stable response is characterized by central flattening and peripheral steepening that is potentiated in a stiffer cornea. Two clinical devices for assessing corneal biomechanics do not yet measure classic biomechanical properties, but rather provide assessment of corneal deformation response. Biomechanical parameters are a function of IOP, and both the cornea and sclera become stiffer as IOP increases. Any assessment of biomechanical parameters must include IOP, and one value of stiffness does not adequately characterize a cornea. Corneal biomechanics plays a role in the outcomes of any procedure in which lamellae are transected. Once the corneal structure has been altered in a manner that includes central thinning, IOP measurements with applanation tonometry are likely not valid, and other technologies should be used.

  5. Biomechanics of the Human Posterior Sclera: Age- and Glaucoma-Related Changes Measured Using Inflation Testing

    PubMed Central

    Coudrillier, Baptiste; Tian, Jing; Alexander, Stephen; Myers, Kristin M.; Quigley, Harry A.; Nguyen, Thao D.

    2012-01-01

    Purpose. The objective of this study was to measure the biomechanical response of the human posterior sclera in vitro and to estimate the effects of age and glaucoma. Methods. Scleral specimens from 22 donors with no history of glaucoma and 11 donors with a history of glaucoma were excised 3 mm posterior to the equator and affixed to an inflation chamber. Optic nerve cross-sections were graded to determine the presence of axon loss. The time-dependent inflation response was measured in a series of pressure-controlled load–unload tests to 30 mm Hg and creep tests to 15 and 30 mm Hg. Circumferential and meridional strains were computed from the digital image correlation displacements, and midposterior stresses were determined from pressure and deformed geometry. Results. Among normal specimens, older age was predictive of a stiffer response and a thinner sclera. In the age group 75 to 93, diagnosed glaucoma eyes with axon damage were thicker than normal eyes. Both damaged and undamaged glaucoma eyes had a different strain response in the peripapillary sclera characterized by a stiffer meridional response. Undamaged glaucoma eyes had slower circumferential creep rates in the peripapillary sclera than normal eyes. Glaucoma eyes were not different from normal eyes in stresses and strains in the midposterior sclera. Conclusions. The observed differences in the biomechanical response of normal and glaucoma sclera may represent baseline properties that contribute to axon damage, or may be characteristics that result from glaucomatous disease. PMID:22395883

  6. Biomechanical ToolKit: Open-source framework to visualize and process biomechanical data.

    PubMed

    Barre, Arnaud; Armand, Stéphane

    2014-04-01

    C3D file format is widely used in the biomechanical field by companies and laboratories to store motion capture systems data. However, few software packages can visualize and modify the integrality of the data in the C3D file. Our objective was to develop an open-source and multi-platform framework to read, write, modify and visualize data from any motion analysis systems using standard (C3D) and proprietary file formats (used by many companies producing motion capture systems). The Biomechanical ToolKit (BTK) was developed to provide cost-effective and efficient tools for the biomechanical community to easily deal with motion analysis data. A large panel of operations is available to read, modify and process data through C++ API, bindings for high-level languages (Matlab, Octave, and Python), and standalone application (Mokka). All these tools are open-source and cross-platform and run on all major operating systems (Windows, Linux, MacOS X). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Discomfort Evaluation of Truck Ingress/Egress Motions Based on Biomechanical Analysis

    PubMed Central

    Choi, Nam-Chul; Lee, Sang Hun

    2015-01-01

    This paper presents a quantitative discomfort evaluation method based on biomechanical analysis results for human body movement, as well as its application to an assessment of the discomfort for truck ingress and egress. In this study, the motions of a human subject entering and exiting truck cabins with different types, numbers, and heights of footsteps were first measured using an optical motion capture system and load sensors. Next, the maximum voluntary contraction (MVC) ratios of the muscles were calculated through a biomechanical analysis of the musculoskeletal human model for the captured motion. Finally, the objective discomfort was evaluated using the proposed discomfort model based on the MVC ratios. To validate this new discomfort assessment method, human subject experiments were performed to investigate the subjective discomfort levels through a questionnaire for comparison with the objective discomfort levels. The validation results showed that the correlation between the objective and subjective discomforts was significant and could be described by a linear regression model. PMID:26067194

  8. Changes in Fatigue, Multiplanar Knee Laxity, and Landing Biomechanics During Intermittent Exercise

    PubMed Central

    Shultz, Sandra J.; Schmitz, Randy J.; Cone, John R.; Henson, Robert A.; Montgomery, Melissa M.; Pye, Michele L.; Tritsch, Amanda J.

    2015-01-01

    Context: Knee laxity increases during exercise. However, no one, to our knowledge, has examined whether these increases contribute to higher-risk landing biomechanics during prolonged, fatiguing exercise. Objectives: To examine associations between changes in fatigue (measured as sprint time [SPTIME]), multiplanar knee laxity (anterior-posterior [APLAX], varus-valgus [VVLAX] knee laxity, and internal-external rotation [IERLAX]) knee laxity and landing biomechanics during prolonged, intermittent exercise. Design: Descriptive laboratory study. Setting: Laboratory and gymnasium. Patients or Other Participants: A total of 30 male (age = 20.3 ± 2.0 years, height = 1.79 ± 0.05 m, mass = 75.2 ± 7.2 kg) and 29 female (age = 20.5 ± 2.3 years, height = 1.67 ± 0.08 m, mass = 61.8 ± 9.0 kg) competitive athletes. Intervention(s): A 90-minute intermittent exercise protocol (IEP) designed to simulate the physiologic and biomechanical demands of a soccer match. Main Outcome Measure(s): We measured SPTIME, APLAX, and landing biomechanics before and after warm-up, every 15 minutes during the IEP, and every 15 minutes for 1 hour after the IEP. We measured VVLAX and IERLAX before and after the warm-up, at 45 and 90 minutes during the IEP, and at 30 minutes after the IEP. We used hierarchical linear modeling to examine associations between exercise-related changes in SPTIME and knee laxity with exercise-related changes in landing biomechanics while controlling for initial (before warm-up) knee laxity. Results: We found that SPTIME had a more global effect on landing biomechanics in women than in men, resulting in a more upright landing and a reduction in landing forces and out-of-plane motions about the knee. As APLAX increased with exercise, women increased their knee internal-rotation motion (P = .02), and men increased their hip-flexion motion and energy-absorption (P = .006) and knee-extensor loads (P = .04). As VVLAX and IERLAX increased, women went through greater knee

  9. Concurrent validation of an inertial measurement system to quantify kicking biomechanics in four football codes.

    PubMed

    Blair, Stephanie; Duthie, Grant; Robertson, Sam; Hopkins, William; Ball, Kevin

    2018-05-17

    Wearable inertial measurement systems (IMS) allow for three-dimensional analysis of human movements in a sport-specific setting. This study examined the concurrent validity of a IMS (Xsens MVN system) for measuring lower extremity and pelvis kinematics in comparison to a Vicon motion analysis system (MAS) during kicking. Thirty footballers from Australian football (n = 10), soccer (n = 10), rugby league and rugby union (n = 10) clubs completed 20 kicks across four conditions. Concurrent validity was assessed using a linear mixed-modelling approach, which allowed the partition of between and within-subject variance from the device measurement error. Results were expressed in raw and standardised units for assessments of differences in means and measurement error, and interpreted via non-clinical magnitude-based inferences. Trivial to small differences were found in linear velocities (foot and pelvis), angular velocities (knee, shank and thigh), sagittal joint (knee and hip) and segment angle (shank and pelvis) means (mean difference: 0.2-5.8%) between the IMS and MAS in Australian football, soccer and the rugby codes. Trivial to small measurement errors (from 0.1 to 5.8%) were found between the IMS and MAS in all kinematic parameters. The IMS demonstrated acceptable levels of concurrent validity compared to a MAS when measuring kicking biomechanics across the four football codes. Wearable IMS offers various benefits over MAS, such as, out-of-laboratory testing, larger measurement range and quick data output, to help improve the ecological validity of biomechanical testing and the timing of feedback. The results advocate the use of IMS to quantify biomechanics of high-velocity movements in sport-specific settings. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Fundamentals of biomechanics in tissue engineering of bone.

    PubMed

    Athanasiou, K A; Zhu, C; Lanctot, D R; Agrawal, C M; Wang, X

    2000-08-01

    The objective of this review is to provide basic information pertaining to biomechanical aspects of bone as they relate to tissue engineering. The review is written for the general tissue engineering reader, who may not have a biomechanical engineering background. To this end, biomechanical characteristics and properties of normal and repair cortical and cancellous bone are presented. Also, this chapter intends to describe basic structure-function relationships of these two types of bone. Special emphasis is placed on salient classical and modern testing methods, with both material and structural properties described.

  11. Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology.

    PubMed

    He, Miao; Ding, Hui; He, Hong; Zhang, Chi; Liu, Liangping; Zhong, Xingwu

    2017-05-17

    The aim of this study was to evaluate corneal biomechanical properties in a population of healthy children in China using corneal visualization Scheimpflug technology (CST). All children underwent complete bi-ocular examinations. CST provided intraocular pressure (IOP) and corneal biomechanical parameters, including time, velocity, length and deformation amplitude at first applanation (A1T, A1V, A1L, A1DA), at second applanation (A2T, A2V, A2L, A2DA), highest concavity time (HCT), maximum deformation amplitude (MDA), peak distance (PD), and radius of curvature (RoC). Pearson correlation analysis was used to assess the impacts of demographic factors, central corneal thickness (CCT), spherical equivalent (SE), and IOP on corneal biomechanics. One hundred eight subjects (32 girls and 76 boys) with the mean age of 10.80 ± 4.13 years (range 4 to18 years) were included in the final analyses. The right and left eyes were highly symmetrical in SE (p = 0.082), IOP (p = 0.235), or CCT (p = 0.210). Mean A1T of the right eyes was 7.424 ± 0.340 ms; the left eyes 7.451 ± 0.365 ms. MDA was 0.993 ± 0.102 mm in the right eyes and 0.982 ± 0.100 mm in the left eyes. Mean HCT of the right eyes was 16.675 ± 0.502 ms; the left eyes 16.735 ± 0.555 ms. All CST parameters of both eye were remarkably symmetrical with the exception of A2L (p = 0.006), A1DA (p = 0.025). The majority of CST parameters of both eyes were significantly correlated with CCT and IOP (p < 0.05). However, age, SE, and sex exert little influence on the CST measurements. This study found interocular symmetry in corneal biomechanics in healthy children eyes. Several CST biomechanical parameters in children are modified by CCT and IOP.

  12. Ankle-Dorsiflexion Range of Motion and Landing Biomechanics

    PubMed Central

    Fong, Chun-Man; Blackburn, J. Troy; Norcross, Marc F.; McGrath, Melanie; Padua, Darin A.

    2011-01-01

    Abstract Context: A smaller amount of ankle-dorsiflexion displacement during landing is associated with less knee-flexion displacement and greater ground reaction forces, and greater ground reaction forces are associated with greater knee-valgus displacement. Additionally, restricted dorsiflexion range of motion (ROM) is associated with greater knee-valgus displacement during landing and squatting tasks. Because large ground reaction forces and valgus displacement and limited knee-flexion displacement during landing are anterior cruciate ligament (ACL) injury risk factors, dorsiflexion ROM restrictions may be associated with a greater risk of ACL injury. However, it is unclear whether clinical measures of dorsiflexion ROM are associated with landing biomechanics. Objective: To evaluate relationships between dorsiflexion ROM and landing biomechanics. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Thirty-five healthy, physically active volunteers. Intervention(s): Passive dorsiflexion ROM was assessed under extended-knee and flexed-knee conditions. Landing biomechanics were assessed via an optical motion-capture system interfaced with a force plate. Main Outcome Measure(s): Dorsiflexion ROM was measured in degrees using goniometry. Knee-flexion and knee-valgus displacements and vertical and posterior ground reaction forces were calculated during the landing task. Simple correlations were used to evaluate relationships between dorsiflexion ROM and each biomechanical variable. Results: Significant correlations were noted between extended-knee dorsiflexion ROM and knee-flexion displacement (r  =  0.464, P  =  .029) and vertical (r  =  −0.411, P  =  .014) and posterior (r  =  −0.412, P  =  .014) ground reaction forces. All correlations for flexed-knee dorsiflexion ROM and knee-valgus displacement were nonsignificant. Conclusions: Greater dorsiflexion ROM was associated with greater knee

  13. Nanoindentation measurements of biomechanical properties in mature and newly formed bone tissue surrounding an implant.

    PubMed

    Vayron, Romain; Barthel, Etienne; Mathieu, Vincent; Soffer, Emmanuel; Anagnostou, Fani; Haiat, Guillaume

    2012-02-01

    The characterization of the biomechanical properties of newly formed bone tissue around implants is important to understand the osseointegration process. The objective of this study is to investigate the evolution of the hardness and indentation modulus of newly formed bone tissue as a function of healing time. To do so, a nanoindentation device is employed following a multimodality approach using histological analysis. Coin-shaped implants were placed in vivo at a distance of 200 μm from the cortical bone surface, leading to an initially empty cavity of 200 μm * 4.4 mm. Three New Zealand White rabbits were sacrificed after 4, 7, and 13 weeks of healing time. The bone samples were embedded and analyzed using histological analyses, allowing to distinguish mature and newly formed bone tissue. The bone mechanical properties were then measured in mature and newly formed bone tissue. The results are within the range of hardness and apparent Young's modulus values reported in previous literature. One-way ANOVA test revealed a significant effect of healing time on the indentation modulus (p < 0.001, F = 111.24) and hardness (p < 0.02, F = 3.47) of bone tissue. A Tukey-Kramer analysis revealed that the biomechanical properties of newly formed bone tissue (4 weeks) were significantly different from those of mature bone tissue. The comparison with the results obtained in Mathieu et al. (2011, "Micro-Brillouin Scattering Measurements in Mature and Newly Formed Bone Tissue Surrounding an Implant," J. Biomech. Eng., 133, 021006). shows that bone mass density increases by approximately 13.5% between newly formed bone (7 weeks) and mature bone tissue.

  14. Brillouin microscopy: assessing ocular tissue biomechanics.

    PubMed

    Yun, Seok Hyun; Chernyak, Dimitri

    2018-07-01

    Assessment of corneal biomechanics has been an unmet clinical need in ophthalmology for many years. Many researchers and clinicians have identified corneal biomechanics as source of variability in refractive procedures and one of the main factors in keratoconus. However, it has been difficult to accurately characterize corneal biomechanics in patients. The recent development of Brillouin light scattering microscopy heightens the promise of bringing biomechanics into the clinic. The aim of this review is to overview the progress and discuss prospective applications of this new technology. Brillouin microscopy uses a low-power near-infrared laser beam to determine longitudinal modulus or mechanical compressibility of tissue by analyzing the return signal spectrum. Human clinical studies have demonstrated significant difference in the elastic properties of normal corneas versus corneas diagnosed with mild and severe keratoconus. Clinical data have also shown biomechanical changes after corneal cross-linking treatment of keratoconus patients. Brillouin measurements of the crystalline lens and sclera have also been demonstrated. Brillouin microscopy is a promising technology under commercial development at present. The technique enables physicians to characterize the biomechanical properties of ocular tissues.

  15. Corneal biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements.

    PubMed

    Sahin, Afsun; Bayer, Atilla; Ozge, Gökhan; Mumcuoğlu, Tarkan

    2009-10-01

    To investigate possible corneal biomechanical changes in patients with diabetes mellitus and understand the influence of such changes on intraocular pressure measurements. The study group was composed of 120 eyes from 61 healthy control subjects and 81 eyes from 43 diabetic subjects. IOP was measured first with an ocular response analyzer (ORA) and subsequently with a Goldmann applanation tonometer (GAT). Central corneal thickness (CCT) was measured with an ultrasonic pachymeter attached to the ORA. Axial length (AL), anterior chamber depth (ACD), and keratometry readings were acquired with partial coherence laser interferometry during the same visit before all IOP and CCT determinations were made. Corneal hysteresis (CH) was found to be significantly lower in diabetic patients when compared with healthy control subjects (9.51 +/- 1.82 mm Hg vs. 10.41 +/- 1.66 mm Hg, P < 0.0001). There was no significant difference in terms of corneal resistance factor (CRF; P = 0.8). Mean CCT, GAT IOP, Goldmann-correlated IOP (IOPg), and corneal-compensated IOP (IOPcc) were significantly higher in diabetic patients than in healthy control subjects (P = 0.01 for CCT, P < 0.0001 for GAT IOP, IOPg, and IOPcc). Diabetes affects corneal biomechanics and results in lower CH values than those in healthy control subjects, which may cause clinically relevant high IOP measurements independent of CCT.

  16. Preliminary evidence of altered biomechanics in adolescents with Juvenile Fibromyalgia

    PubMed Central

    Sil, Soumitri; Thomas, Staci; DiCesare, Christopher; Strotman, Daniel; Ting, Tracy V; Myer, Gregory; Kashikar-Zuck, Susmita

    2014-01-01

    Objective Juvenile Fibromyalgia (JFM) is characterized by chronic musculoskeletal pain and marked reduction in physical activity. Despite recommendations for exercise to manage JFM pain, exercise adherence is poor. Due to pain and activity avoidance, adolescents with JFM are at risk for altered joint mechanics that may make them susceptible to increased pain and reduced tolerance for exercise. The primary aim of this study was to assess functional deficits in patients with JFM compared to healthy controls using objective biomechanical assessment. Methods Female adolescent patients with JFM (n=17) and healthy controls (n=14) completed biomechanical assessments including gait analysis and tests of lower extremity strength (isokinetic knee extension/flexion, hip abduction) and functional performance (Drop Vertical Jump) along with self-report measures of disability (Functional Disability Inventory), pain intensity, depressive symptoms (Children’s Depression Inventory), and fear of movement (Tampa Scale of Kinesiophobia). Results Patients with JFM demonstrated mild deficiencies in walking gait and functional performance (p’s <. 05), significantly lower left knee extension and flexion strength (19–26% deficit) and bilateral hip abduction strength (33–37%) compared to healthy controls (p’s < .008). Patients with JFM reported significantly higher functional disability, pain intensity, depressive symptoms, and fear of movement relative to controls (p’s < 0.01). Conclusions This study showed that adolescents with JFM exhibited objective alterations in biomechanics, and self-reported fear of movement which may reinforce their activity avoidance. Interventions for JFM should include a focus on correcting functional deficits and instilling greater confidence in adolescents with JFM to engage in exercise to improve functional outcomes. PMID:25156509

  17. Biomechanical pulping of kenaf

    Treesearch

    Aziz Ahmed; Masood Akhtar; Gary C. Myers; Gary M. Scott

    1999-01-01

    The objective of this study was to investigate the effect of fungal pretreatment of whole kenaf prior to refining on refiner electrical energy consumption, paper strength, and optical properties. We also explored the suitability of whole kenaf biomechanical pulp for making newsprint in terms of ISO brightness and strength properties. Kenaf was sterilized by autoclaving...

  18. An Evidence-Based Videotaped Running Biomechanics Analysis.

    PubMed

    Souza, Richard B

    2016-02-01

    Running biomechanics play an important role in the development of injuries. Performing a running biomechanics analysis on injured runners can help to develop treatment strategies. This article provides a framework for a systematic video-based running biomechanics analysis plan based on the current evidence on running injuries, using 2-dimensional (2D) video and readily available tools. Fourteen measurements are proposed in this analysis plan from lateral and posterior video. Identifying simple 2D surrogates for 3D biomechanic variables of interest allows for widespread translation of best practices, and have the best opportunity to impact the highly prevalent problem of the injured runner. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. [The development of an oral biomechanical testing instrument].

    PubMed

    Zhang, X H; Sun, X D; Lin, Z

    2000-03-01

    An oral biomechanical testing instrument, which is portable, powered with batteries and controlled by single chip microcomputer, was described. The instrument was characterized by its multichannel, high accuracy, low power dissipation, wide rage of force measurement and stable performance. It can be used for acquisiting, displaying and storing data. And it may be expected to be an ideal instrument for oral biomechanical measurements.

  20. Relationships between job organisational factors, biomechanical and psychosocial exposures.

    PubMed

    Bao, Stephen S; Kapellusch, Jay M; Merryweather, Andrew S; Thiese, Matthew S; Garg, Arun; Hegmann, Kurt T; Silverstein, Barbara A

    2016-01-01

    The relationships between work organisational, biomechanical and psychosocial factors were studied using cross-sectional data from a pooled dataset of 1834 participants. The work organisational factors included: job rotation, overtime work, having second jobs and work pace. Task and job level biomechanical variables were obtained through sub-task data collected in the field or analysed in the laboratory. Psychosocial variables were collected based on responses to 10 questions. The results showed that job rotations had significant effects on all biomechanical and most psychosocial measures. Those with job rotations generally had higher job biomechanical stressors, and lower job satisfaction. Overtime work was associated with higher job biomechanical stressors, and possibly self-reported physical exhaustion. Those having second jobs reported getting along with co-workers well. Work pace had significant influences on all biomechanical stressors, but its impact on job biomechanical stressors and psychosocial effects are complicated. The findings are based on a large number of subjects collected by three research teams in diverse US workplaces. Job rotation practices used in many workplaces may not be effective in reducing job biomechanical stressors for work-related musculoskeletal disorders. Overtime work is also associated with higher biomechanical stressors.

  1. Dental Enamel: Genes Define Biomechanics

    PubMed Central

    Rauth, Rick J.; Potter, Karen S.; Ngan, Amanda Y.-W.; Saad, Deema M.; Mehr, Rana; Luong, Vivian Q.; Schuetter, Verna L.; Miklus, Vetea G.; Chang, PeiPei; Paine, Michael L.; Lacruz, Rodrigo S.; Snead, Malcolm L.; White, Shane N.

    2010-01-01

    Regulated gene expression assembles an extracellular proteinaceous matrix to control biomineralization and the resultant biomechanical function of tooth enamel. The importance of the dominant enamel matrix protein, amelogenin (Amel); a minor transiently expressed protein, dentin sialoprotein (Dsp); an electrogenic sodium bicarbonate cotransporter (NBCe1); the timely removal of the proteinaceous matrix by a serine protease, Kallikrein-4 (Klk4); and the late-stage expression of Amelotin (Amtn) on enamel biomechanical function were demonstrated and measured using mouse models. PMID:20066874

  2. A comparison in a youth population between those with and without a history of concussion using biomechanical reconstruction.

    PubMed

    Post, Andrew; Hoshizaki, T Blaine; Gilchrist, Michael D; Koncan, David; Dawson, Lauren; Chen, Wesley; Ledoux, Andrée-Anne; Zemek, Roger

    2017-04-01

    OBJECTIVE Concussion is a common topic of research as a result of the short- and long-term effects it can have on the affected individual. Of particular interest is whether previous concussions can lead to a biomechanical susceptibility, or vulnerability, to incurring further head injuries, particularly for youth populations. The purpose of this research was to compare the impact biomechanics of a concussive event in terms of acceleration and brain strains of 2 groups of youths: those who had incurred a previous concussion and those who had not. It was hypothesized that the youths with a history of concussion would have lower-magnitude biomechanical impact measures than those who had never suffered a previous concussion. METHODS Youths who had suffered a concussion were recruited from emergency departments across Canada. This pool of patients was then separated into 2 categories based on their history of concussion: those who had incurred 1 or more previous concussions, and those who had never suffered a concussion. The impact event that resulted in the brain injury was reconstructed biomechanically using computational, physical, and finite element modeling techniques. The output of the events was measured in biomechanical parameters such as energy, force, acceleration, and brain tissue strain to determine if those patients who had a previous concussion sustained a brain injury at lower magnitudes than those who had no previously reported concussion. RESULTS The results demonstrated that there was no biomechanical variable that could distinguish between the concussion groups with a history of concussion versus no history of concussion. CONCLUSIONS The results suggest that there is no measureable biomechanical vulnerability to head impact related to a history of concussions in this youth population. This may be a reflection of the long time between the previous concussion and the one reconstructed in the laboratory, where such a long period has been associated with

  3. Biomechanical evaluation of heel elevation on load transfer — experimental measurement and finite element analysis

    NASA Astrophysics Data System (ADS)

    Luximon, Yan; Luximon, Ameersing; Yu, Jia; Zhang, Ming

    2012-02-01

    In spite of ill-effects of high heel shoes, they are widely used for women. Hence, it is essential to understand the load transfer biomechanics in order to design better fit and comfortable shoes. In this study, both experimental measurement and finite element analysis were used to evaluate the biomechanical effects of heel height on foot load transfer. A controlled experiment was conducted using custom-designed platforms. Under different weight-bearing conditions, peak plantar pressure, contact area and center of pressure were analyzed. A three-dimensional finite element foot model was used to simulate the high-heel support and to predict the internal stress distributions and deformations for different heel heights. Results from both experiment and model indicated that heel elevations had significant effects on all variables. When heel elevation increased, the center of pressure shifted from the midfoot region to the forefoot region, the contact area was reduced by 26% from 0 to 10.2 cm heel and the internal stress of foot bones increased. Prediction results also showed that the strain and total tension force of plantar fascia was minimum at 5.1 cm heel condition. This study helps to better understand the biomechanical behavior of foot, and to provide better suggestions for design parameters of high heeled shoes.

  4. Physical modelling in biomechanics.

    PubMed Central

    Koehl, M A R

    2003-01-01

    Physical models, like mathematical models, are useful tools in biomechanical research. Physical models enable investigators to explore parameter space in a way that is not possible using a comparative approach with living organisms: parameters can be varied one at a time to measure the performance consequences of each, while values and combinations not found in nature can be tested. Experiments using physical models in the laboratory or field can circumvent problems posed by uncooperative or endangered organisms. Physical models also permit some aspects of the biomechanical performance of extinct organisms to be measured. Use of properly scaled physical models allows detailed physical measurements to be made for organisms that are too small or fast to be easily studied directly. The process of physical modelling and the advantages and limitations of this approach are illustrated using examples from our research on hydrodynamic forces on sessile organisms, mechanics of hydraulic skeletons, food capture by zooplankton and odour interception by olfactory antennules. PMID:14561350

  5. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions - Effect of Velocity

    PubMed Central

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2013-01-01

    Background Inertial measurement of motion with Attitude and Heading Reference Systems (AHRS) is emerging as an alternative to 3D motion capture systems in biomechanics. The objectives of this study are: 1) to describe the absolute and relative accuracy of multiple units of commercially available AHRS under various types of motion; and 2) to evaluate the effect of motion velocity on the accuracy of these measurements. Methods The criterion validity of accuracy was established under controlled conditions using an instrumented Gimbal table. AHRS modules were carefully attached to the center plate of the Gimbal table and put through experimental static and dynamic conditions. Static and absolute accuracy was assessed by comparing the AHRS orientation measurement to those obtained using an optical gold standard. Relative accuracy was assessed by measuring the variation in relative orientation between modules during trials. Findings Evaluated AHRS systems demonstrated good absolute static accuracy (mean error < 0.5o) and clinically acceptable absolute accuracy under condition of slow motions (mean error between 0.5o and 3.1o). In slow motions, relative accuracy varied from 2o to 7o depending on the type of AHRS and the type of rotation. Absolute and relative accuracy were significantly affected (p<0.05) by velocity during sustained motions. The extent of that effect varied across AHRS. Interpretation Absolute and relative accuracy of AHRS are affected by environmental magnetic perturbations and conditions of motions. Relative accuracy of AHRS is mostly affected by the ability of all modules to locate the same global reference coordinate system at all time. Conclusions Existing AHRS systems can be considered for use in clinical biomechanics under constrained conditions of use. While their individual capacity to track absolute motion is relatively consistent, the use of multiple AHRS modules to compute relative motion between rigid bodies needs to be optimized according to

  6. CT-derived Biomechanical Metrics Improve Agreement Between Spirometry and Emphysema

    PubMed Central

    Bhatt, Surya P.; Bodduluri, Sandeep; Newell, John D.; Hoffman, Eric A.; Sieren, Jessica C.; Han, Meilan K.; Dransfield, Mark T.; Reinhardt, Joseph M.

    2016-01-01

    Rationale and Objectives Many COPD patients have marked discordance between FEV1 and degree of emphysema on CT. Biomechanical differences between these patients have not been studied. We aimed to identify reasons for the discordance between CT and spirometry in some patients with COPD. Materials and Methods Subjects with GOLD stage I–IV from a large multicenter study (COPDGene) were arranged by percentiles of %predicted FEV1 and emphysema on CT. Three categories were created using differences in percentiles: Catspir with predominant airflow obstruction/minimal emphysema, CatCT with predominant emphysema/minimal airflow obstruction, and Catmatched with matched FEV1 and emphysema. Image registration was used to derive Jacobian determinants, a measure of lung elasticity, anisotropy and strain tensors, to assess biomechanical differences between groups. Regression models were created with the above categories as outcome variable, adjusting for demographics, scanner type, quantitative CT-derived emphysema, gas trapping, and airway thickness (Model 1), and after adding biomechanical CT metrics (Model 2). Results Jacobian determinants, anisotropy and strain tensors were strongly associated with FEV1. With Catmatched as control, Model 2 predicted Catspir and CatCT better than Model 1 (Akaike Information Criterion, AIC 255.8 vs. 320.8). In addition to demographics, the strongest independent predictors of FEV1 were Jacobian mean (β= 1.60,95%CI = 1.16 to 1.98; p<0.001), coefficient of variation (CV) of Jacobian (β= 1.45,95%CI = 0.86 to 2.03; p<0.001) and CV strain (β= 1.82,95%CI = 0.68 to 2.95; p = 0.001). CVs of Jacobian and strain are both potential markers of biomechanical lung heterogeneity. Conclusions CT-derived measures of lung mechanics improve the link between quantitative CT and spirometry, offering the potential for new insights into the linkage between regional parenchymal destruction and global decrement in lung function in COPD patients. PMID:27055745

  7. Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

    PubMed

    Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo

    2017-01-01

    To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye.

  8. Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas

    PubMed Central

    Nemeth, Gabor; Szalai, Eszter; Hassan, Ziad; Lipecz, Agnes; Flasko, Zsuzsa; Modis, Laszlo

    2017-01-01

    AIM To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. METHODS Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. RESULTS Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CONCLUSIONS CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye. PMID:28251079

  9. Applications of biomechanics for prevention of work-related musculoskeletal disorders.

    PubMed

    Garg, Arun; Kapellusch, Jay M

    2009-01-01

    This paper summarises applications of biomechanical principles and models in industry to control musculoskeletal disorders of the low back and upper extremity. Applications of 2-D and 3-D biomechanical models to estimate compressive force on the low back, the strength requirements of jobs, application of guidelines for overhead work and application of strain index and threshold limit value to address distal upper extremity musculoskeletal disorders are presented. Several case studies applied in the railroad industry, manufacturing, healthcare and warehousing are presented. Finally, future developments needed for improved biomechanical applications in industry are discussed. The information presented will be of value to practising ergonomists to recognise how biomechanics has played a significant role in identifying causes of musculoskeletal disorders and controlling them in the workplace. In particular, the information presented will help practising ergonomists with how physical stresses can be objectively quantified.

  10. Comparing handrim biomechanics for treadmill and overground wheelchair propulsion

    PubMed Central

    Kwarciak, Andrew M.; Turner, Jeffrey T.; Guo, Liyun; Richter, W. Mark

    2010-01-01

    Study design Cross-sectional study. Objectives To compare handrim biomechanics recorded during overground propulsion to those recorded during propulsion on a motor-driven treadmill. Setting Biomechanics laboratory. Methods Twenty-eight manual wheelchair users propelled their own wheelchairs, at a self-selected speed, on a low-pile carpet and on a wheelchair accessible treadmill. Handrim biomechanics were recorded with an OptiPush instrumented wheelchair wheel. Results Across the two conditions, all handrim biomechanics were found to be similar and highly correlated (r > 0.85). Contact angle, peak force, average force, and peak axle moment differed by 1.6% or less across the two conditions. While not significant, power output and cadence tended to be slightly higher for the treadmill condition (3.5% and 3.6%, respectively), due to limitations in adjusting the treadmill grade. Conclusion Based on the results of this study, a motor-driven treadmill can serve as a valid surrogate for overground studies of wheelchair propulsion. PMID:21042332

  11. Objectivity in Quantum Measurement

    NASA Astrophysics Data System (ADS)

    Li, Sheng-Wen; Cai, C. Y.; Liu, X. F.; Sun, C. P.

    2018-06-01

    The objectivity is a basic requirement for the measurements in the classical world, namely, different observers must reach a consensus on their measurement results, so that they believe that the object exists "objectively" since whoever measures it obtains the same result. We find that this simple requirement of objectivity indeed imposes an important constraint upon quantum measurements, i.e., if two or more observers could reach a consensus on their quantum measurement results, their measurement basis must be orthogonal vector sets. This naturally explains why quantum measurements are based on orthogonal vector basis, which is proposed as one of the axioms in textbooks of quantum mechanics. The role of the macroscopicality of the observers in an objective measurement is discussed, which supports the belief that macroscopicality is a characteristic of classicality.

  12. Objectivity in Quantum Measurement

    NASA Astrophysics Data System (ADS)

    Li, Sheng-Wen; Cai, C. Y.; Liu, X. F.; Sun, C. P.

    2018-05-01

    The objectivity is a basic requirement for the measurements in the classical world, namely, different observers must reach a consensus on their measurement results, so that they believe that the object exists "objectively" since whoever measures it obtains the same result. We find that this simple requirement of objectivity indeed imposes an important constraint upon quantum measurements, i.e., if two or more observers could reach a consensus on their quantum measurement results, their measurement basis must be orthogonal vector sets. This naturally explains why quantum measurements are based on orthogonal vector basis, which is proposed as one of the axioms in textbooks of quantum mechanics. The role of the macroscopicality of the observers in an objective measurement is discussed, which supports the belief that macroscopicality is a characteristic of classicality.

  13. Why National Biomechanics Day?

    PubMed

    DeVita, Paul

    2018-04-11

    National Biomechanics Day (NBD) seeks to expand the influence and impact of Biomechanics on our society by expanding the awareness of Biomechanics among young people. NBD will manifest this goal through worldwide, synchronized and coordinated celebrations and demonstrations of all things Biomechanics with high school students. NBD invites all Biomechanists to participate in NBD 2018, http://nationalbiomechanicsday.asbweb.org/. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Ultrasonic model and system for measurement of corneal biomechanical properties and validation on phantoms.

    PubMed

    Liu, Jun; He, Xiaoyin; Pan, Xueliang; Roberts, Cynthia J

    2007-01-01

    Non-invasive measurement of biomechanical properties of corneas may provide important information for ocular disease management and therapeutic procedures. An ultrasonic non-destructive evaluation method with a wave propagation model was developed to determine corneal biomechanical properties in vivo. In this study, we tested the feasibility of the approach in differentiating the mechanical properties of soft contact lenses as corneal phantoms. Three material types of soft contact lenses (six samples in each group) were measured using a broadband ultrasound transducer. The ultrasonic reflections from the contact lenses were recorded by a 500MHz/8-bit digitizer, and displayed and processed by a PC. A reference signal was recorded to compute the normalized power spectra using Fast Fourier Transformation. An inverse algorithm based on least-squares minimization was used to reconstruct three parameters of the contact lenses: density, thickness, and elastic constants lambda+2micro. The thickness of each sample was verified using an electronic thickness gauge, and the averaged density for each type of lenses was verified using Archimedes' principle and manufacturer's report. Our results demonstrated that the ultrasonic system was able to differentiate the elastic properties of the three types of the soft contact lenses with statistical significance (P-value<0.001). The reconstructed thicknesses and densities agreed well with the independent measurements. Our studies on corneal phantoms indicated that the ultrasonic system was sensitive and accurate in measuring the material properties of cornea-like structures. It is important to optimize the system for in vivo measurements.

  15. Invertebrate biomechanics.

    PubMed

    Patek, S N; Summers, A P

    2017-05-22

    Invertebrate biomechanics focuses on mechanical analyses of non-vertebrate animals, which at root is no different in aim and technique from vertebrate biomechanics, or for that matter the biomechanics of plants and fungi. But invertebrates are special - they are fabulously diverse in form, habitat, and ecology and manage this without the use of hard, internal skeletons. They are also numerous and, in many cases, tractable in an experimental and field setting. In this Primer, we will probe three axes of invertebrate diversity: worms (Phylum Annelida), spiders (Class Arachnida) and insects (Class Insecta); three habitats: subterranean, terrestrial and airborne; and three integrations with other fields: ecology, engineering and evolution. Our goal is to capture the field of invertebrate biomechanics, which has blossomed from having a primary focus on discoveries at the interface of physics and biology to being inextricably linked with integrative challenges that span biology, physics, mathematics and engineering. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Platelet biomechanics, platelet bioenergetics, and applications to clinical practice and translational research.

    PubMed

    George, Mitchell J; Bynum, James; Nair, Prajeeda; Cap, Andrew P; Wade, Charles E; Cox, Charles S; Gill, Brijesh S

    2018-07-01

    The purpose of this review is to explore the relationship between platelet bioenergetics and biomechanics and how this relationship affects the clinical interpretation of platelet function devices. Recent experimental and technological advances highlight platelet bioenergetics and biomechanics as alternative avenues for collecting clinically relevant data. Platelet bioenergetics drive energy production for key biomechanical processes like adhesion, spreading, aggregation, and contraction. Platelet function devices like thromboelastography, thromboelastometry, and aggregometry measure these biomechanical processes. Platelet storage, stroke, sepsis, trauma, or the activity of antiplatelet drugs alters measures of platelet function. However, the specific mechanisms governing these alterations in platelet function and how they relate to platelet bioenergetics are still under investigation.

  17. Recent microfluidic devices for studying gamete and embryo biomechanics.

    PubMed

    Lai, David; Takayama, Shuichi; Smith, Gary D

    2015-06-25

    The technical challenges of biomechanic research such as single cell analysis at a high monetary cost, labor, and time for just a small number of measurements is a good match to the strengths of microfluidic devices. New scientific discoveries in the fertilization and embryo development process, of which biomechanics is a major subset of interest, is crucial to fuel the continual improvement of clinical practice in assisted reproduction. The following review will highlight some recent microfluidic devices tailored for gamete and embryo biomechanics where biomimicry arises as a major theme of microfluidic device design and function, and the application of fundamental biomechanic principles are used to improve outcomes of cryopreservation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Biomechanics of occlusion--implications for oral rehabilitation.

    PubMed

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. © 2015 John Wiley & Sons Ltd.

  19. Hominin Hip Biomechanics: Changing Perspectives.

    PubMed

    Warrener, Anna G

    2017-05-01

    The shape of the human pelvis reflects the unique demands placed on the hip abductor muscles (gluteus medius and gluteus minimus), which stabilize the body in the frontal plane during bipedal locomotion. This morphological shift occurred early in hominin evolution, yet important shape differences between hominin species have led to significant disagreement about abductor function and locomotor capability in these extinct taxa. A static biomechanical model that relies on a close association between skeletal measurements of the pelvis and femur has traditionally been used to reconstruct hip biomechanics in these species. However, experimental biomechanical approaches have highlighted the dynamic nature of mediolateral balance in walking and running, challenging the assumptions of the static hip model. This article reviews traditional approaches for understanding hip abductor function, shows how they have been applied to the fossil hominin record, and discusses new techniques that integrate the dynamic nature of mediolateral balance during human locomotion. Anat Rec, 300:932-945, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  20. Research Techniques in Biomechanics.

    ERIC Educational Resources Information Center

    Ward, Terry

    Biomechanics involves the biological human beings interacting with his/her mechanical environment. Biomechanics research is being done in connection with sport, physical education, and general motor behavior, and concerns mechanics independent of implements. Biomechanics research falls in the following two general categories: (1) that specific…

  1. Wearable sensors objectively measure gait parameters in Parkinson’s disease

    PubMed Central

    Marxreiter, Franz; Gossler, Julia; Kohl, Zacharias; Reinfelder, Samuel; Gassner, Heiko; Aminian, Kamiar; Eskofier, Bjoern M.; Winkler, Jürgen; Klucken, Jochen

    2017-01-01

    Distinct gait characteristics like short steps and shuffling gait are prototypical signs commonly observed in Parkinson’s disease. Routinely assessed by observation through clinicians, gait is rated as part of categorical clinical scores. There is an increasing need to provide quantitative measurements of gait, e.g. to provide detailed information about disease progression. Recently, we developed a wearable sensor-based gait analysis system as diagnostic tool that objectively assesses gait parameter in Parkinson’s disease without the need of having a specialized gait laboratory. This system consists of inertial sensor units attached laterally to both shoes. The computed target of measures are spatiotemporal gait parameters including stride length and time, stance phase time, heel-strike and toe-off angle, toe clearance, and inter-stride variation from gait sequences. To translate this prototype into medical care, we conducted a cross-sectional study including 190 Parkinson’s disease patients and 101 age-matched controls and measured gait characteristics during a 4x10 meter walk at the subjects’ preferred speed. To determine intraindividual changes in gait, we monitored the gait characteristics of 63 patients longitudinally. Cross-sectional analysis revealed distinct spatiotemporal gait parameter differences reflecting typical Parkinson’s disease gait characteristics including short steps, shuffling gait, and postural instability specific for different disease stages and levels of motor impairment. The longitudinal analysis revealed that gait parameters were sensitive to changes by mirroring the progressive nature of Parkinson’s disease and corresponded to physician ratings. Taken together, we successfully show that wearable sensor-based gait analysis reaches clinical applicability providing a high biomechanical resolution for gait impairment in Parkinson’s disease. These data demonstrate the feasibility and applicability of objective wearable sensor

  2. Lower-extremity biomechanics during forward and lateral stepping activities in older adults

    PubMed Central

    Wang, Man-Ying; Flanagan, Sean; Song, Joo-Eun; Greendale, Gail A.; Salem, George J.

    2012-01-01

    Objective To characterize the lower-extremity biomechanics associated with stepping activities in older adults. Design Repeated-measures comparison of kinematics and kinetics associated with forward step-up and lateral step-up activities. Background Biomechanical analysis may be used to assess the effectiveness of various ‘in-home activities’ in targeting appropriate muscle groups and preserving functional strength and power in elders. Methods Data were analyzed from 21 participants (mean 74.7 yr (standard deviation, 4.4 yr)) who performed the forward and lateral step-up activities while instrumented for biomechanical analysis. Motion analysis equipment, inverse dynamics equations, and repeated measures anovas were used to contrast the maximum joint angles, peak net joint moments, angular impulse, work, and power associated with the activities. Results The lateral step-up resulted in greater maximum knee flexion (P < 0.001) and ankle dorsiflexion angles (P < 0.01). Peak joint moments were similar between exercises. The forward step-up generated greater peak hip power (P < 0.05) and total work (P < 0.001); whereas, the lateral step-up generated greater impulse (P < 0.05), work (P < 0.01), and power (P < 0.05) at the knee and ankle. Conclusions In older adults, the forward step-up places greater demand on the hip extensors, while lateral step-up places greater demand on the knee extensors and ankle plantar flexors. PMID:12620784

  3. Arch index and running biomechanics in children aged 10-14 years.

    PubMed

    Hollander, Karsten; Stebbins, Julie; Albertsen, Inke Marie; Hamacher, Daniel; Babin, Kornelia; Hacke, Claudia; Zech, Astrid

    2018-03-01

    While altered foot arch characteristics (high or low) are frequently assumed to influence lower limb biomechanics and are suspected to be a contributing factor for injuries, the association between arch characteristics and lower limb running biomechanics in children is unclear. Therefore, the aim of this study was to investigate the relationship between a dynamically measured arch index and running biomechanics in healthy children. One hundred and one children aged 10-14 years were included in this study and underwent a biomechanical investigation. Plantar distribution (Novel, Emed) was used to determine the dynamic arch index and 3D motion capture (Vicon) to measure running biomechanics. Linear mixed models were established to determine the association between dynamic arch index and foot strike patterns, running kinematics, kinetics and temporal-spatial outcomes. No association was found between dynamic arch index and rate of rearfoot strikes (p = 0.072). Of all secondary outcomes, only the foot progression angle was associated with the dynamic arch index (p = 0.032) with greater external rotation in lower arched children. Overall, we found only few associations between arch characteristics and running biomechanics in children. However, altered foot arch characteristics are of clinical interest. Future studies should focus on detailed foot biomechanics and include clinically diagnosed high and low arched children. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Identification of biomechanical properties of the cornea: the ocular response analyzer.

    PubMed

    Terai, Naim; Raiskup, Frederik; Haustein, Michael; Pillunat, Lutz E; Spoerl, Eberhard

    2012-07-01

    Several methods have been devised for measuring geometric parameters of the cornea but, until now, the biomechanics of the cornea have been largely ignored. The relatively new Ocular Response Analyzer (ORA) provides such biomechanical information. In order to correctly interpret the underlying biomechanics of ORA data, we review reported ORA measurements and provide a compendium of factors influencing these measurements, with discussion of possible explanations for ORA measurement results. This review comprised a literature search using "ocular response analyzer" and "ocular response analyser" as keywords. We reviewed and compared reported results from recent ORA studies so obtained, with an eye to understanding corneal biomechanics. Several ORA biomechanical parameters of the cornea - corneal hysteresis (CH) and corneal resistant factor (CRF) - characterize the viscoelastic properties of the cornea, especially those of the ground substance. The impact on CH and CRF values of various independent factors, e.g. intraocular pressure (IOP), age, central corneal thickness (CCT), and corneal swelling, are discussed. The impact on CH and CRF of treatment-related structural changes of the cornea, i.e. those occurring after refractive surgical procedures, placement of intracorneal rings, and collagen crosslinking (CXL), as well as pathological changes of the cornea, e.g. those resulting from keratoconus, edema, and glaucoma, are discussed. Changes in CRF and CH may be reflective of structural changes in the ground substance of the cornea. Thus, ORA provides invaluable information for delineating biomechanical conditions pertaining to the cornea, with special regard to ocular diseases, e.g. keratoconus and glaucoma.

  5. A pilot study of biomechanical assessment before and after an integrative training program for adolescents with juvenile fibromyalgia.

    PubMed

    Tran, Susan T; Thomas, Staci; DiCesare, Christopher; Pfeiffer, Megan; Sil, Soumitri; Ting, Tracy V; Williams, Sara E; Myer, Gregory D; Kashikar-Zuck, Susmita

    2016-07-22

    Adolescents with juvenile fibromyalgia (JFM) tend to be very sedentary and avoid participation in physical activity. A prior study suggested that JFM patients show altered biomechanics compared to healthy adolescents which may make them more prone to pain/injury during exercise. A new intervention combining well established cognitive behavioral therapy (CBT) techniques with specialized neuromuscular exercise -Fibromyalgia Integrative Training for Teens (FIT Teens) was developed and shown to be promising in improving functioning in adolescents with JFM. In contrast to traditional exercise programs such as aerobic or resistance training, neuromuscular training is a tailored approach which targets gait, posture, balance and movement mechanics which form the foundation for safe exercise participation with reduced risk for injury or pain (and hence more tolerable by JFM patients). The aim of this pilot feasibility study was to establish whether objective biomechanical assessment including sophisticated 3-D motion analysis would be useful in measuring improvements in strength, balance, gait, and functional performance after participation in the 8-week FIT Teens program. Eleven female participants with JFM (ages 12-18 years) completed pre- and post-treatment assessments of biomechanics, including walking gait analysis, lower extremity strength assessment, functional performance, and dynamic postural stability. Descriptive data indicated that mechanics of walking gait and functional performance appeared to improve after treatment. Hip abduction strength and dynamic postural control also demonstrated improvements bilaterally. Overall, the results of this pilot study offer initial evidence for the utility of biomechanical assessment to objectively demonstrate observable changes in biomechanical performance after an integrated training intervention for youth with JFM. If replicated in larger controlled studies, findings would suggest that through the FIT Teens intervention

  6. Biomechanics in Schools.

    ERIC Educational Resources Information Center

    Vincent, J. F. V.

    1980-01-01

    Examines current usage of the term "biomechanics" and emphasizes the importance of differentiating between structure and material. Describes current prolects in biomechanics and lists four points about the educational significance of the field. (GS)

  7. Diagnostic Assessment of Preparedness of Level One Sports Science Students for Biomechanics Modules

    ERIC Educational Resources Information Center

    Dixon, Sharon J.

    2005-01-01

    The primary objective of this study was to investigate the use of a diagnostic test to assess the preparedness of level one students for a sports biomechanics module. During their first week at university, a cohort of 108 students completed a diagnostic test at the end of their first lecture in sports biomechanics, with no prior notice. Upon…

  8. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING THE DOUBLE-BUNDLE TECHNIQUE – EVALUATION IN THE BIOMECHANICS LABORATORY

    PubMed Central

    D'Elia, Caio Oliveira; Bitar, Alexandre Carneiro; Castropil, Wagner; Garofo, Antônio Guilherme Padovani; Cantuária, Anita Lopes; Orselli, Maria Isabel Veras; Luques, Isabela Ugo; Duarte, Marcos

    2015-01-01

    Objective: The objective of this study was to describe the methodology of knee rotation analysis using biomechanics laboratory instruments and to present the preliminary results from a comparative study on patients who underwent anterior cruciate ligament (ACL) reconstruction using the double-bundle technique. Methods: The protocol currently used in our laboratory was described. Three-dimensional kinematic analysis was performed and knee rotation amplitude was measured on eight normal patients (control group) and 12 patients who were operated using the double-bundle technique, by means of three tasks in the biomechanics laboratory. Results: No significant differences between operated and non-operated sides were shown in relation to the mean amplitudes of gait, gait with change in direction or gait with change in direction when going down stairs (p > 0.13). Conclusion: The preliminary results did not show any difference in the double-bundle ACL reconstruction technique in relation to the contralateral side and the control group. PMID:27027003

  9. Verification, Validation and Sensitivity Studies in Computational Biomechanics

    PubMed Central

    Anderson, Andrew E.; Ellis, Benjamin J.; Weiss, Jeffrey A.

    2012-01-01

    Computational techniques and software for the analysis of problems in mechanics have naturally moved from their origins in the traditional engineering disciplines to the study of cell, tissue and organ biomechanics. Increasingly complex models have been developed to describe and predict the mechanical behavior of such biological systems. While the availability of advanced computational tools has led to exciting research advances in the field, the utility of these models is often the subject of criticism due to inadequate model verification and validation. The objective of this review is to present the concepts of verification, validation and sensitivity studies with regard to the construction, analysis and interpretation of models in computational biomechanics. Specific examples from the field are discussed. It is hoped that this review will serve as a guide to the use of verification and validation principles in the field of computational biomechanics, thereby improving the peer acceptance of studies that use computational modeling techniques. PMID:17558646

  10. Role of Aquaporin 0 in lens biomechanics.

    PubMed

    Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer

  11. Preliminary evidence of altered biomechanics in adolescents with juvenile fibromyalgia.

    PubMed

    Sil, Soumitri; Thomas, Staci; DiCesare, Christopher; Strotman, Daniel; Ting, Tracy V; Myer, Gregory; Kashikar-Zuck, Susmita

    2015-01-01

    Juvenile fibromyalgia (FM) is characterized by chronic musculoskeletal pain and marked reduction in physical activity. Despite recommendations for exercise to manage juvenile FM pain, exercise adherence is poor. Because of pain and activity avoidance, adolescents with juvenile FM are at risk for altered joint mechanics that may make them susceptible to increased pain and reduced tolerance for exercise. The primary aim of this study was to assess functional deficits in patients with juvenile FM compared to healthy controls using objective biomechanical assessment. Female adolescent patients with juvenile FM (n = 17) and healthy controls (n = 14) completed biomechanical assessments, including gait analysis and tests of lower extremity strength (isokinetic knee extension/flexion and hip abduction) and functional performance (drop vertical jump test) along with self-reported measures of disability (Functional Disability Inventory), pain intensity, depressive symptoms (Children's Depression Inventory), and fear of movement (Tampa Scale of Kinesiophobia). Patients with juvenile FM demonstrated mild deficiencies in walking gait and functional performance (P < 0.05 for both) and significantly lower left knee extension and flexion strength (18-22% deficit) and bilateral hip abduction strength (34-38%) compared with healthy controls (P < 0.008 for all). Patients with juvenile FM reported significantly higher functional disability, pain intensity, depressive symptoms, and fear of movement relative to controls (P < 0.01 for all). This study showed that adolescents with juvenile FM exhibited objective alterations in biomechanics and self-reported fear of movement that may have reinforced their activity avoidance. Interventions for juvenile FM should include a focus on correcting functional deficits and instilling greater confidence in adolescents with juvenile FM to engage in exercise to improve functional outcomes. Copyright © 2015 by the American College of Rheumatology.

  12. Biomechanics of subcellular structures by non-invasive Brillouin microscopy

    NASA Astrophysics Data System (ADS)

    Antonacci, Giuseppe; Braakman, Sietse

    2016-11-01

    Cellular biomechanics play a pivotal role in the pathophysiology of several diseases. Unfortunately, current methods to measure biomechanical properties are invasive and mostly limited to the surface of a cell. As a result, the mechanical behaviour of subcellular structures and organelles remains poorly characterised. Here, we show three-dimensional biomechanical images of single cells obtained with non-invasive, non-destructive Brillouin microscopy with an unprecedented spatial resolution. Our results quantify the longitudinal elastic modulus of subcellular structures. In particular, we found the nucleoli to be stiffer than both the nuclear envelope (p < 0.0001) and the surrounding cytoplasm (p < 0.0001). Moreover, we demonstrate the mechanical response of cells to Latrunculin-A, a drug that reduces cell stiffness by preventing cytoskeletal assembly. Our technique can therefore generate valuable insights into cellular biomechanics and its role in pathophysiology.

  13. Computerized Biomechanical Man-Model

    DTIC Science & Technology

    1976-07-01

    Force Systems Command Wright-Patterson AFB, Ohio ABSTRACT The COMputerized BIomechanical MAN-Model (called COMBIMAN) is a computer interactive graphics...concept was to build a mock- The use of mock-ups for biomechanical evalua- up which permitted the designer to visualize the tion has long been a tool...of the can become an obstacle to design change. Aerospace Medical Research Laboratory, we are developing a computerized biomechanical man-model

  14. Role of Aquaporin 0 in lens biomechanics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sindhu Kumari, S.; Gupta, Neha; Shiels, Alan

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showedmore » the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs

  15. MR elastography to measure the effects of cancer and pathology fixation on prostate biomechanics, and comparison with T 1, T 2 and ADC

    NASA Astrophysics Data System (ADS)

    McGrath, Deirdre M.; Lee, Jenny; Foltz, Warren D.; Samavati, Navid; van der Kwast, Theo; Jewett, Michael A. S.; Chung, Peter; Ménard, Cynthia; Brock, Kristy K.

    2017-02-01

    MRI is under evaluation for image-guided intervention for prostate cancer. The sensitivity and specificity of MRI parameters is determined via correlation with the gold-standard of histopathology. Whole-mount histopathology of prostatectomy specimens can be digitally registered to in vivo imaging for correlation. When biomechanical-based deformable registration is employed to account for deformation during histopathology processing, the ex vivo biomechanical properties are required. However, these properties are altered by pathology fixation, and vary with disease. Hence, this study employs magnetic resonance elastography (MRE) to measure ex vivo prostate biomechanical properties before and after fixation. A quasi-static MRE method was employed to measure high resolution maps of Young’s modulus (E) before and after fixation of canine prostate and prostatectomy specimens (n  =  4) from prostate cancer patients who had previously received radiation therapy. For comparison, T 1, T 2 and apparent diffusion coefficient (ADC) were measured in parallel. E (kPa) varied across clinical anatomy and for histopathology-identified tumor: peripheral zone: 99(±22), central gland: 48(±37), tumor: 85(±53), and increased consistently with fixation (factor of 11  ±  5 p  <  0.02). T 2 decreased consistently with fixation, while changes in T 1 and ADC were more complex and inconsistent. The biomechanics of the clinical prostate specimens varied greatly with fixation, and to a lesser extent with disease and anatomy. The data obtained will improve the precision of prostate pathology correlation, leading to more accurate disease detection and targeting.

  16. Microfluidic analysis of oocyte and embryo biomechanical properties to improve outcomes in assisted reproductive technologies.

    PubMed

    Yanez, Livia Z; Camarillo, David B

    2017-04-01

    Measurement of oocyte and embryo biomechanical properties has recently emerged as an exciting new approach to obtain a quantitative, objective estimate of developmental potential. However, many traditional methods for probing cell mechanical properties are time consuming, labor intensive and require expensive equipment. Microfluidic technology is currently making its way into many aspects of assisted reproductive technologies (ART), and is particularly well suited to measure embryo biomechanics due to the potential for robust, automated single-cell analysis at a low cost. This review will highlight microfluidic approaches to measure oocyte and embryo mechanics along with their ability to predict developmental potential and find practical application in the clinic. Although these new devices must be extensively validated before they can be integrated into the existing clinical workflow, they could eventually be used to constantly monitor oocyte and embryo developmental progress and enable more optimal decision making in ART. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Corneal biomechanical properties in thyroid eye disease.

    PubMed

    Karabulut, Gamze Ozturk; Kaynak, Pelin; Altan, Cıgdem; Ozturker, Can; Aksoy, Ebru Funda; Demirok, Ahmet; Yılmaz, Omer Faruk

    2014-06-01

    The purpose of this study is to investigate the effect of thyroid eye disease (TED) on the measurement of corneal biomechanical properties and the relationship between these parameters and disease manifestations. A total of 54 eyes of 27 individuals with TED and 52 eyes of 30 healthy control participants were enrolled. Thyroid ophthalmopathy activity was defined using the VISA (vision, inflammation, strabismus, and appearance/exposure) classification for TED. The intraocular pressure (IOP) measurement with Goldmann applanation tonometer (GAT), axial length (AL), keratometry, and central corneal thickness (CCT) measurements were taken from each patient. Corneal biomechanical properties, including corneal hysteresis (CH) and corneal resistance factor (CRF) and noncontact IOP measurements, Goldmann-correlated IOP (IOPg) and corneal-compensated IOP (IOPcc) were measured with the Ocular Response Analyzer (ORA) using the standard technique. Parameters such as best corrected visual acuity, axial length, central corneal thickness, and corneal curvature were not statistically significant between the two groups (p > 0.05). IOP measured with GAT was higher in participants with TED (p < 0.001). The CH of TED patients was significantly lower than that of the control group. There was no significant difference in the corneal resistance factor between groups. However, IOPg and IOPcc were significantly higher in TED patients. CH and VISA grading of TED patients showed a negative correlation (p = 0.007). In conclusion, TED affects the corneal biomechanical properties by decreasing CH. IOP with GAT and IOPg is found to be increased in these patients. As the severity of TED increases, CH decreases in these patients. Copyright © 2014. Published by Elsevier B.V.

  18. Different Exercise Training Interventions and Drop-Landing Biomechanics in High School Female Athletes

    PubMed Central

    Pfile, Kate R.; Hart, Joseph M.; Herman, Daniel C.; Hertel, Jay; Kerrigan, D. Casey; Ingersoll, Christopher D.

    2013-01-01

    Context: Anterior cruciate ligament (ACL) injuries are common in female athletes and are related to poor neuromuscular control. Comprehensive neuromuscular training has been shown to improve biomechanics; however, we do not know which component of neuromuscular training is most responsible for the changes. Objective: To assess the efficacy of either a 4-week core stability program or plyometric program in altering lower extremity and trunk biomechanics during a drop vertical jump (DVJ). Design: Cohort study. Setting: High school athletic fields and motion analysis laboratory. Patients or Other Participants: Twenty-three high school female athletes (age = 14.8 ± 0.8 years, height = 1.7 ± 0.07 m, mass = 57.7 ± 8.5 kg). Intervention(s): Independent variables were group (core stability, plyometric, control) and time (pretest, posttest). Participants performed 5 DVJs at pretest and posttest. Intervention participants engaged in a 4-week core stability or plyometric program. Main Outcome Measure(s): Dependent variables were 3-dimensional hip, knee, and trunk kinetics and kinematics during the landing phase of a DVJ. We calculated the group means and associated 95% confidence intervals for the first 25% of landing. Cohen d effect sizes with 95% confidence intervals were calculated for all differences. Results: We found within-group differences for lower extremity biomechanics for both intervention groups (P ≤ .05). The plyometric group decreased the knee-flexion and knee internal-rotation angles and the knee-flexion and knee-abduction moments. The core stability group decreased the knee-flexion and knee internal-rotation angles and the hip-flexion and hip internal-rotation moments. The control group decreased the knee external-rotation moment. All kinetic changes had a strong effect size (Cohen d > 0.80). Conclusions: Both programs resulted in biomechanical changes, suggesting that both types of exercises are warranted for ACL injury prevention and should be

  19. Simulated parallel annealing within a neighborhood for optimization of biomechanical systems.

    PubMed

    Higginson, J S; Neptune, R R; Anderson, F C

    2005-09-01

    Optimization problems for biomechanical systems have become extremely complex. Simulated annealing (SA) algorithms have performed well in a variety of test problems and biomechanical applications; however, despite advances in computer speed, convergence to optimal solutions for systems of even moderate complexity has remained prohibitive. The objective of this study was to develop a portable parallel version of a SA algorithm for solving optimization problems in biomechanics. The algorithm for simulated parallel annealing within a neighborhood (SPAN) was designed to minimize interprocessor communication time and closely retain the heuristics of the serial SA algorithm. The computational speed of the SPAN algorithm scaled linearly with the number of processors on different computer platforms for a simple quadratic test problem and for a more complex forward dynamic simulation of human pedaling.

  20. MRI and CT lung biomarkers: Towards an in vivo understanding of lung biomechanics.

    PubMed

    Young, Heather M; Eddy, Rachel L; Parraga, Grace

    2017-09-29

    The biomechanical properties of the lung are necessarily dependent on its structure and function, both of which are complex and change over time and space. This makes in vivo evaluation of lung biomechanics and a deep understanding of lung biomarkers, very challenging. In patients and animal models of lung disease, in vivo evaluations of lung structure and function are typically made at the mouth and include spirometry, multiple-breath gas washout tests and the forced oscillation technique. These techniques, and the biomarkers they provide, incorporate the properties of the whole organ system including the parenchyma, large and small airways, mouth, diaphragm and intercostal muscles. Unfortunately, these well-established measurements mask regional differences, limiting their ability to probe the lung's gross and micro-biomechanical properties which vary widely throughout the organ and its subcompartments. Pulmonary imaging has the advantage in providing regional, non-invasive measurements of healthy and diseased lung, in vivo. Here we summarize well-established and emerging lung imaging tools and biomarkers and how they may be used to generate lung biomechanical measurements. We review well-established and emerging lung anatomical, microstructural and functional imaging biomarkers generated using synchrotron x-ray tomographic-microscopy (SRXTM), micro-x-ray computed-tomography (micro-CT), clinical CT as well as magnetic resonance imaging (MRI). Pulmonary imaging provides measurements of lung structure, function and biomechanics with high spatial and temporal resolution. Imaging biomarkers that reflect the biomechanical properties of the lung are now being validated to provide a deeper understanding of the lung that cannot be achieved using measurements made at the mouth. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Biomechanical versus inertial information: stable individual differences in perception of self-rotation.

    PubMed

    Bruggeman, Hugo; Piuneu, Vadzim S; Rieser, John J; Pick, Herbert L

    2009-10-01

    When turning without vision or audition, people tend to perceive their locomotion as a change in heading relative to objects in the remembered surroundings. Such perception of self-rotation depends on sensitivity to information for movement from biomechanical activity of the locomotor system or from inertial activation of the vestibular and postural systems. The authors report 3 experiments that investigated the relative contributions of biomechanical and inertial information to perceiving the speed of self-rotation. Using a circular treadmill, the proportions of the 2 sources of proprioceptive information were varied, creating walking conditions with a constant rate of biomechanical activity but with variable speeds of rotation relative to inertial space. The results reveal stable individual differences in sensitivity to information for the perception of locomotion. Just more than half of the participants based their perceived speed of self-rotation on biomechanical information, whereas the others based theirs on inertial information. PsycINFO Database Record (c) 2009 APA, all rights reserved.

  2. Interpreting locomotor biomechanics from the morphology of human footprints.

    PubMed

    Hatala, Kevin G; Wunderlich, Roshna E; Dingwall, Heather L; Richmond, Brian G

    2016-01-01

    Fossil hominin footprints offer unique direct windows to the locomotor behaviors of our ancestors. These data could allow a clearer understanding of the evolution of human locomotion by circumventing issues associated with indirect interpretations of habitual locomotor patterns from fossil skeletal material. However, before we can use fossil hominin footprints to understand better the evolution of human locomotion, we must first develop an understanding of how locomotor biomechanics are preserved in, and can be inferred from, footprint morphologies. In this experimental study, 41 habitually barefoot modern humans created footprints under controlled conditions in which variables related to locomotor biomechanics could be quantified. Measurements of regional topography (depth) were taken from 3D models of those footprints, and principal components analysis was used to identify orthogonal axes that described the largest proportions of topographic variance within the human experimental sample. Linear mixed effects models were used to quantify the influences of biomechanical variables on the first five principal axes of footprint topographic variation, thus providing new information on the biomechanical variables most evidently expressed in the morphology of human footprints. The footprint's overall depth was considered as a confounding variable, since biomechanics may be linked to the extent to which a substrate deforms. Three of five axes showed statistically significant relationships with variables related to both locomotor biomechanics and substrate displacement; one axis was influenced only by biomechanics and another only by the overall depth of the footprint. Principal axes of footprint morphological variation were significantly related to gait type (walking or running), kinematics of the hip and ankle joints and the distribution of pressure beneath the foot. These results provide the first quantitative framework for developing hypotheses regarding the

  3. Strength and Jump Biomechanics of Elite and Recreational Female Youth Soccer Players

    PubMed Central

    Chrisman, Sara P.; O'Kane, John W.; Polissar, Nayak L.; Tencer, Allan F.; Mack, Christopher D.; Levy, Marni R.; Schiff, Melissa A.

    2012-01-01

    Context Most researchers investigating soccer injuries have studied elite athletes because they have greater athletic-exposure hours than other athletes, but most youth participate at the recreational level. If risk factors for injury vary by soccer level, then recommendations generated using research with elite youth soccer players might not generalize to recreational players. Objective To examine injury risk factors of strength and jump biomechanics by soccer level in female youth athletes and to determine whether research recommendations based on elite youth athletes could be generalized to recreational players. Design Cross-sectional study. Setting Seattle Youth Soccer Association. Patients or Other Participants Female soccer players (N = 92) aged 11 to 14 years were recruited from 4 randomly selected elite (n = 50; age = 12.5 years, 95% confidence interval [95% CI]) = 12.3, 12.8 years; height = 157.8 cm, 95% CI = 155.2, 160.3 cm; mass = 49.9 kg, 95% CI = 47.3, 52.6 kg) and 4 randomly selected recreational (n = 42; age = 13.2 years, 95% CI = 13.0, 13.5 years; height = 161.1 cm, 95% CI = 159.2, 163.1 cm; mass = 50.6 kg, 95% CI = 48.3, 53.0 kg) soccer teams. Main Outcome Measure(s) Players completed a questionnaire about demographics, history of previous injury, and soccer experience. Physical therapists used dynamometry to measure hip strength (abduction, adduction, extension, flexion) and knee strength (flexion, extension) and Sportsmetrics to measure vertical jump height and jump biomechanics. We compared all measurements by soccer level using linear regression to adjust for age and mass. Results Elite players were similar to recreational players in all measures of hip and knee strength, vertical jump height, and normalized knee separation (a valgus estimate generated using Sportsmetrics). Conclusions Female elite youth players and recreational players had similar lower extremity strength and jump biomechanics. This suggests that recommendations generated from

  4. The Effect of Pterygium and Pterygium Surgery on Corneal Biomechanics.

    PubMed

    Koç, Mustafa; Yavrum, Fuat; Uzel, Mehmet Murat; Aydemir, Emre; Özülken, Kemal; Yılmazbaş, Pelin

    2018-01-01

    To evaluate the effect of pterygium and pterygium surgery on corneal biomechanics by ocular response analyzer (ORA, Reichert, USA). This study considered 68 eyes (from 34 patients with a mean age of 21.2±7.1 years) with unilateral nasal, primary pterygium (horizontal length <4 mm), and having undergone pterygium excision and conjunctival autografting. Pterygium length and area were measured from a photograph of the anterior segment using Image J program. ORA measurements were obtained before surgery and after the first month of the surgery. The measurements of the eyes with pterygium and healthy eyes were compared to evaluate the effect of pterygium. Similarly, measurements obtained before and after surgery were compared to evaluate the effect of pterygium surgery on corneal biomechanics. The correlation of the ORA measurements with the pterygium area was evaluated. Mean pterygium horizontal length and area were 3.31±1.43 mm and 6.82±2.17 mm 2 , respectively. There was no statistically significant difference between the eyes with and without pterygium in corneal hysteresis (CH, p=0.442), corneal resistance factor (CRF, p=0.554), corneal-compensated intraocular pressure (IOP cc , p=0.906), and Goldmann-correlated IOP (IOP g , p=0.836). All preoperative parameters decreased after surgery; however, none of them were statistically significant (CH, p=0.688; CRF, p=0.197; IOP cc , p=0.503; IOP g , p=0.231). There were no correlations between pterygium area and ORA measurements (p>0.05). Pterygium <4 mm and its surgical excision did not affect corneal biomechanics. These results may be taken into account when cornea biomechanics, mainly intraocular pressure measurements, are important.

  5. Qualitative biomechanical principles for application in coaching.

    PubMed

    Knudson, Duane

    2007-01-01

    Many aspects of human movements in sport can be readily understood by Newtonian rigid-body mechanics. Many of these laws and biomechanical principles, however, are counterintuitive to a lot of people. There are also several problems in the application of biomechanics to sports, so the application of biomechanics in the qualitative analysis of sport skills by many coaches has been limited. Biomechanics scholars have long been interested in developing principles that facilitate the qualitative application of biomechanics to improve movement performance and reduce the risk of injury. This paper summarizes the major North American efforts to establish a set of general biomechanical principles of movement, and illustrates how principles can be used to improve the application of biomechanics in the qualitative analysis of sport technique. A coach helping a player with a tennis serve is presented as an example. The standardization of terminology for biomechanical principles is proposed as an important first step in improving the application ofbiomechanics in sport. There is also a need for international cooperation and research on the effectiveness of applying biomechanical principles in the coaching of sport techniques.

  6. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time

    PubMed Central

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2015-01-01

    Background Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. Methods This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. Findings Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. Interpretation The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. Conclusions Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their

  7. Challenge of biomechanics.

    PubMed

    Volokh, K Y

    2013-06-01

    The application of mechanics to biology--biomechanics--bears great challenges due to the intricacy of living things. Their dynamism, along with the complexity of their mechanical response (which in itself involves complex chemical, electrical, and thermal phenomena) makes it very difficult to correlate empirical data with theoretical models. This difficulty elevates the importance of useful biomechanical theories compared to other fields of engineering. Despite inherent imperfections of all theories, a well formulated theory is crucial in any field of science because it is the basis for interpreting observations. This is all-the-more vital, for instance, when diagnosing symptoms, or planning treatment to a disease. The notion of interpreting empirical data without theory is unscientific and unsound. This paper attempts to fortify the importance of biomechanics and invigorate research efforts for those engineers and mechanicians who are not yet involved in the field. It is not aimed here, however, to give an overview of biomechanics. Instead, three unsolved problems are formulated to challenge the readers. At the micro-scale, the problem of the structural organization and integrity of the living cell is presented. At the meso-scale, the enigma of fingerprint formation is discussed. At the macro-scale, the problem of predicting aneurysm ruptures is reviewed. It is aimed here to attract the attention of engineers and mechanicians to problems in biomechanics which, in the author's opinion, will dominate the development of engineering and mechanics in forthcoming years.

  8. Morphology and biomechanics of human heart

    NASA Astrophysics Data System (ADS)

    Chelnokova, Natalia O.; Golyadkina, Anastasiya A.; Kirillova, Irina V.; Polienko, Asel V.; Ivanov, Dmitry V.

    2016-03-01

    Object of study: A study of the biomechanical characteristics of the human heart ventricles was performed. 80 hearts were extracted during autopsy of 80 corpses of adults (40 women and 40 men) aged 31-70 years. The samples were investigated in compliance with the recommendations of the ethics committee. Methods: Tension and compression tests were performed with help of the uniaxial testing machine Instron 5944. Cardiometry was also performed. Results: In this work, techniques for human heart ventricle wall biomechanical properties estimation were developed. Regularities of age and gender variability in deformative and strength properties of the right and left ventricle walls were found. These properties were characterized by a smooth growth of myocardial tissue stiffness and resistivity at a relatively low strain against reduction in their strength and elasticity from 31-40 to 61-70 years. It was found that tissue of the left ventricle at 61-70 years had a lower stretchability and strength compared with tissues of the right ventricle and septum. These data expands understanding of the morphological organization of the heart ventricles, which is very important for the development of personalized medicine. Taking into account individual, age and gender differences of the heart ventricle tissue biomechanical characteristics allows to rationally choosing the type of patching materials during reconstructive operations on heart.

  9. Empirical Measurements of Biomechanical Anisotropy of the Human Vocal Fold Lamina Propria

    PubMed Central

    Kelleher, Jordan E.; Siegmund, Thomas; Du, Mindy; Naseri, Elhum; Chan, Roger W.

    2013-01-01

    The vocal folds are known to be mechanically anisotropic due to the microstructural arrangement of fibrous proteins such as collagen and elastin in the lamina propria. Even though this has been known for many years, the biomechanical anisotropic properties have rarely been experimentally studied. We propose that an indentation procedure can be used with uniaxial tension in order to obtain an estimate of the biomechanical anisotropy within a single specimen. Experiments were performed on the lamina propria of three male and three female human vocal folds dissected from excised larynges. Two experiments were conducted: each specimen was subjected to cyclic uniaxial tensile loading in the longitudinal (i.e. anterior-posterior) direction, and then to cyclic indentation loading in the transverse (i.e. medial-lateral) direction. The indentation experiment was modeled as contact on a transversely isotropic half-space using the Barnett-Lothe tensors. The longitudinal elastic modulus EL was computed from the tensile test, and the transverse elastic modulus ET and longitudinal shear modulus GL were obtained by inverse analysis of the indentation force-displacement response. It was discovered that the average of EL/ET was 14 for the vocal ligament and 39 for the vocal fold cover specimens. Also, the average of EL/GL, a parameter important for models of phonation, was 28 for the vocal ligament and 54 for the vocal fold cover specimens. These measurements of anisotropy could contribute to more accurate models of fundamental frequency regulation and provide potentially better insights into the mechanics of vocal fold vibration. PMID:22886592

  10. [Biomechanical condition of the cornea as a new indicator for pathological and structural changes].

    PubMed

    Spörl, E; Terai, N; Haustein, M; Böhm, A G; Raiskup-Wolf, F; Pillunat, L E

    2009-06-01

    Several methods permit the measurement of geometric parameters of the cornea, but until now biomechanical conditions of the cornea have been ignored (e.g. in refractive corneal surgery). Besides the geometric condition, biomechanical properties of the cornea have been shown to influence applanation measurement of intra-ocular pressure (IOP) and epidemiological studies have identified corneal thickness as an independent risk factor for the development and progression of glaucoma. The aim of this investigation was to characterize the biomechanical properties of the cornea using the ocular response analyzer (ORA). The ocular response analyzer (ORA) is a new method available for non-contact measurement of the biomechanical properties of the cornea. We evaluated the reproducibility of measurements, the difference between static and dynamic factors and the impact of independent factors (e.g. IOP, age, CCT, swelling of the cornea) on 2,500 measurements of corneal hysteresis (CH) and corneal resistance factor (CRF). In a large sample size we observed changes in CH and CRF after refractive surgery procedures (LASIK, UV-A cross-linking, keratoplasty) and in other corneal disorders (keratoconus, corneal dystrophies). CRF and CH changes may reflect structural changes of the cornea. Thus, the ORA provides valuable information for a better understanding and characterization of the biomechanical condition of the cornea, especially with regard to diseases such as keratoconus and glaucoma.

  11. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING THE DOUBLE-BUNDLE TECHNIQUE - EVALUATION IN THE BIOMECHANICS LABORATORY.

    PubMed

    D'Elia, Caio Oliveira; Bitar, Alexandre Carneiro; Castropil, Wagner; Garofo, Antônio Guilherme Padovani; Cantuária, Anita Lopes; Orselli, Maria Isabel Veras; Luques, Isabela Ugo; Duarte, Marcos

    2011-01-01

    The objective of this study was to describe the methodology of knee rotation analysis using biomechanics laboratory instruments and to present the preliminary results from a comparative study on patients who underwent anterior cruciate ligament (ACL) reconstruction using the double-bundle technique. The protocol currently used in our laboratory was described. Three-dimensional kinematic analysis was performed and knee rotation amplitude was measured on eight normal patients (control group) and 12 patients who were operated using the double-bundle technique, by means of three tasks in the biomechanics laboratory. No significant differences between operated and non-operated sides were shown in relation to the mean amplitudes of gait, gait with change in direction or gait with change in direction when going down stairs (p > 0.13). The preliminary results did not show any difference in the double-bundle ACL reconstruction technique in relation to the contralateral side and the control group.

  12. Biomechanics and mechanobiology in functional tissue engineering

    PubMed Central

    Guilak, Farshid; Butler, David L.; Goldstein, Steven A.; Baaijens, Frank P.T.

    2014-01-01

    The field of tissue engineering continues to expand and mature, and several products are now in clinical use, with numerous other preclinical and clinical studies underway. However, specific challenges still remain in the repair or regeneration of tissues that serve a predominantly biomechanical function. Furthermore, it is now clear that mechanobiological interactions between cells and scaffolds can critically influence cell behavior, even in tissues and organs that do not serve an overt biomechanical role. Over the past decade, the field of “functional tissue engineering” has grown as a subfield of tissue engineering to address the challenges and questions on the role of biomechanics and mechanobiology in tissue engineering. Originally posed as a set of principles and guidelines for engineering of load-bearing tissues, functional tissue engineering has grown to encompass several related areas that have proven to have important implications for tissue repair and regeneration. These topics include measurement and modeling of the in vivo biomechanical environment; quantitative analysis of the mechanical properties of native tissues, scaffolds, and repair tissues; development of rationale criteria for the design and assessment of engineered tissues; investigation of the effects biomechanical factors on native and repair tissues, in vivo and in vitro; and development and application of computational models of tissue growth and remodeling. Here we further expand this paradigm and provide examples of the numerous advances in the field over the past decade. Consideration of these principles in the design process will hopefully improve the safety, efficacy, and overall success of engineered tissue replacements. PMID:24818797

  13. Biomechanics and mechanobiology in functional tissue engineering.

    PubMed

    Guilak, Farshid; Butler, David L; Goldstein, Steven A; Baaijens, Frank P T

    2014-06-27

    The field of tissue engineering continues to expand and mature, and several products are now in clinical use, with numerous other preclinical and clinical studies underway. However, specific challenges still remain in the repair or regeneration of tissues that serve a predominantly biomechanical function. Furthermore, it is now clear that mechanobiological interactions between cells and scaffolds can critically influence cell behavior, even in tissues and organs that do not serve an overt biomechanical role. Over the past decade, the field of "functional tissue engineering" has grown as a subfield of tissue engineering to address the challenges and questions on the role of biomechanics and mechanobiology in tissue engineering. Originally posed as a set of principles and guidelines for engineering of load-bearing tissues, functional tissue engineering has grown to encompass several related areas that have proven to have important implications for tissue repair and regeneration. These topics include measurement and modeling of the in vivo biomechanical environment; quantitative analysis of the mechanical properties of native tissues, scaffolds, and repair tissues; development of rationale criteria for the design and assessment of engineered tissues; investigation of the effects biomechanical factors on native and repair tissues, in vivo and in vitro; and development and application of computational models of tissue growth and remodeling. Here we further expand this paradigm and provide examples of the numerous advances in the field over the past decade. Consideration of these principles in the design process will hopefully improve the safety, efficacy, and overall success of engineered tissue replacements. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Thioridazine dose-related effects on biomechanical force platform measures of sway in young and old men.

    PubMed

    Liu, Y J; Stagni, G; Walden, J G; Shepherd, A M; Lichtenstein, M J

    1998-04-01

    Thioridazine (TDZ) is associated with an increased risk of falls. The purpose of this study was to determine whether (1) thioridazine increases Biomechanics Force Platform (BFP) measures of sway in a dose-related manner, (2) there is a difference in sway between young and old men, (3) there is a correlation between sway and orthostatic changes in BP and HR. Seven younger (aged 20-42) and five older (aged 70-76) healthy male volunteers received, in a randomized order double-blind design, a single oral dose of 0, 25, and 50 mg of TDZ on three separate days at least 7 days apart and 75 mg on the fourth day of the study. Sway and blood pressure were measured for 24 hours. A general clinical research center. Biomechanics force platform measures of postural sway were measured as the movement of the center of pressure. The elliptical area (EA) and average velocity (AV) were calculated with eyes open and eyes closed. Blood pressure and heart rate were measured for 5 minutes supine and 5 minutes standing. Thioridazine increases BFP sway in a dose-dependent manner. EA increased from 0.56 (SD = .51) cm2 for placebo to 0.88 (SD = 1.09) cm2 for 75 mg TDZ. AV increased from 1.07 (SD = .27) cm/sec, placebo, to 1.43 (SD = .55) cm/sec, 75 mg TDZ. Older men swayed more than younger men. Changes followed the expected time course for TDZ. EA and AV were associated with HR and BP, e.g., SBP versus ln(EA) and ln(AV) (r = -0.21 and r = -0.22, respectively; P < .0001). Thioridazine increases validated measures of fall risk dose dependently in young and old men. This may explain the effects of neuroleptic drugs on fall risk in older people.

  15. Are biomechanical changes necessary for tumor progression?

    NASA Astrophysics Data System (ADS)

    Kas, Josef A.

    2014-03-01

    Already the Roman Celsus recognized rigid tissue as characteristic for solid tumors. Conversely, changes towards a weaker cytoskeleton have been described as a feature of cancer cells since the early days of tumor biology. It remains unclear if a carcinoma's rigid signature stems from more inflexible cells or is caused by the stroma. Despite that the importance of cell biomechanics for tumor progression becomes more and more evident the chicken-and-egg problem to what extent cancer cells already change their mechanical properties within the solid tumor in order to transgress its boundary or mechanical changes are induced by the microenvironment when the cell has left the tumor has been discussed highly controversial. Comprehensive clinical biomechanical measurements only exist from tumor tissue without the possibility to identify individual cells or from individual cancer cells from pleural effusions. Since the biomechanical properties of cells in carcinomas remain unknown measurements on individual cells that directly stem out of primary tumor samples are required, which we have conducted. We found in cervix and mammary carcinomas a distinctive increase of softer cells as well as contractile cells. A soft and contractile cell is like a strong elastic rope. The cell can generate a strong tensile tension to pull its self along and is soft against compression to avoid jamming.

  16. Biomechanics of Interspinous Devices

    PubMed Central

    Parchi, Paolo D.; Evangelisti, Gisberto; Vertuccio, Antonella; Piolanti, Nicola; Andreani, Lorenzo; Cervi, Valentina; Giannetti, Christian; Calvosa, Giuseppe; Lisanti, Michele

    2014-01-01

    A number of interspinous devices (ISD) have been introduced in the lumbar spine implant market. Unfortunately, the use of these devices often is not associated with real comprehension of their biomechanical role. The aim of this paper is to review the biomechanical studies about interspinous devices available in the literature to allow the reader a better comprehension of the effects of these devices on the treated segment and on the adjacent segments of the spine. For this reason, our analysis will be limited to the interspinous devices that have biomechanical studies published in the literature. PMID:25114923

  17. Automation and apps for clinical dental biomechanics.

    PubMed

    Adams, Bruce W

    2016-09-01

    The aim of this research summary is to introduce the current and ongoing work using smartphone video, tracking markers to measure musculoskeletal disorders of cranial and mandibular origin, and the potential significance of the technology to doctors and therapists. The MPA™ biomechanical measuring apps are in beta trials with various doctors and therapists. The technique requires substantial image processing and statistical analysis, best suited to server-side processing. A smartphone environment has enabled a virtual laboratory, which provides automated generation of graphics and in some cases automated interpretation. The system enables highly accurate real-time biomechanics studies using only a smartphone and tracking markers. Despite the technical challenges in setting up and testing of the virtual environment and with interpretation of clinical relevance, the trials have enabled a demonstration of real-time biomechanics studies. The technology has prompted a lot of discussion about the relevance of rapid assessment tools in clinical practice. It seems that a prior bias against motion tracking and its relevance is very strong with occlusion related use cases, yet there has been a general agreement about the use case for cranial movement tracking in managing complex issues related to the head, neck, and TMJ. Measurement of cranial and mandibular functions using a smartphone video as the input have been investigated. Ongoing research will depend upon doctors and therapists to provide feedback as to which uses are considered clinically relevant.

  18. Biomechanical, psychosocial and individual risk factors predicting low back functional impairment among furniture distribution employees

    PubMed Central

    Ferguson, Sue A.; Allread, W. Gary; Burr, Deborah L.; Heaney, Catherine; Marras, William S.

    2013-01-01

    Background Biomechanical, psychosocial and individual risk factors for low back disorder have been studied extensively however few researchers have examined all three risk factors. The objective of this was to develop a low back disorder risk model in furniture distribution workers using biomechanical, psychosocial and individual risk factors. Methods This was a prospective study with a six month follow-up time. There were 454 subjects at 9 furniture distribution facilities enrolled in the study. Biomechanical exposure was evaluated using the American Conference of Governmental Industrial Hygienists (2001) lifting threshold limit values for low back injury risk. Psychosocial and individual risk factors were evaluated via questionnaires. Low back health functional status was measured using the lumbar motion monitor. Low back disorder cases were defined as a loss of low back functional performance of −0.14 or more. Findings There were 92 cases of meaningful loss in low back functional performance and 185 non cases. A multivariate logistic regression model included baseline functional performance probability, facility, perceived workload, intermediated reach distance number of exertions above threshold limit values, job tenure manual material handling, and age combined to provide a model sensitivity of 68.5% and specificity of 71.9%. Interpretation: The results of this study indicate which biomechanical, individual and psychosocial risk factors are important as well as how much of each risk factor is too much resulting in increased risk of low back disorder among furniture distribution workers. PMID:21955915

  19. Biomechanics of oral mucosa

    PubMed Central

    Chen, Junning; Ahmad, Rohana; Li, Wei; Swain, Michael; Li, Qing

    2015-01-01

    The prevalence of prosthodontic treatment has been well recognized, and the need is continuously increasing with the ageing population. While the oral mucosa plays a critical role in the treatment outcome, the associated biomechanics is not yet fully understood. Using the literature available, this paper provides a critical review on four aspects of mucosal biomechanics, including static, dynamic, volumetric and interactive responses, which are interpreted by its elasticity, viscosity/permeability, apparent Poisson's ratio and friction coefficient, respectively. Both empirical studies and numerical models are analysed and compared to gain anatomical and physiological insights. Furthermore, the clinical applications of such biomechanical knowledge on the mucosa are explored to address some critical concerns, including stimuli for tissue remodelling (interstitial hydrostatic pressure), pressure–pain thresholds, tissue displaceability and residual bone resorption. Through this review, the state of the art in mucosal biomechanics and their clinical implications are discussed for future research interests, including clinical applications, computational modelling, design optimization and prosthetic fabrication. PMID:26224566

  20. Biomechanical responses of PMHS in moderate-speed rear impacts and development of response targets for evaluating the internal and external biofidelity of ATDS.

    PubMed

    Kang, Yun-Seok; Bolte, John H; Moorhouse, Kevin; Donnelly, Bruce; Herriott, Rodney; Mallory, Ann

    2012-10-01

    The objectives of this study were to obtain biomechanical responses of post mortem human subjects (PMHS) by subjecting them to two moderate-speed rear impact sled test conditions (8.5g, 17 km/h; 10.5g, 24 km/h) while positioned in an experimental seat system, and to create biomechanical targets for internal and external biofidelity evaluation of rear impact ATDs. The experimental seat was designed to measure external loads on the head restraint (4 load cells), seat back (6 load cells), and seat pan (4 load cells) such that subject dynamic interaction with the seat could be evaluated. This seat system was capable of simulating the dynamic characteristics of modern vehicle seat backs by considering the moment-rotation properties of a typical passenger vehicle, thus providing a more realistic test environment than using a rigid seat with a non-rotating seat back as done in previous studies. Instrumentation used to measure biomechanical responses of the PMHS included both accelerometers and angular rate sensors (ARS). A total of fourteen sled tests using eight PMHS (males 175.8 ± 6.2 cm of stature and 78.4 ± 7.2 kg of weight) provided data sets of seven PMHS for both test conditions. The biomechanical responses are described at both speeds, and cervical spine injuries are documented. Biomechanical targets are also created for internal and external biofidelity evaluation of rear impact anthropomorphic test devices (ATDs).

  1. Confidence crisis of results in biomechanics research.

    PubMed

    Knudson, Duane

    2017-11-01

    Many biomechanics studies have small sample sizes and incorrect statistical analyses, so reporting of inaccurate inferences and inflated magnitude of effects are common in the field. This review examines these issues in biomechanics research and summarises potential solutions from research in other fields to increase the confidence in the experimental effects reported in biomechanics. Authors, reviewers and editors of biomechanics research reports are encouraged to improve sample sizes and the resulting statistical power, improve reporting transparency, improve the rigour of statistical analyses used, and increase the acceptance of replication studies to improve the validity of inferences from data in biomechanics research. The application of sports biomechanics research results would also improve if a larger percentage of unbiased effects and their uncertainty were reported in the literature.

  2. Important learning factors in high- and low-achieving students in undergraduate biomechanics.

    PubMed

    Hsieh, ChengTu; Knudson, Duane

    2017-07-21

    The purpose of the present study was to document crucial factors associated with students' learning of biomechanical concepts, particularly between high- and-low achieving students. Students (N = 113) from three introductory biomechanics classes at two public universities volunteered for the study. Two measures of students' learning were obtained, final course grade and improvement on the Biomechanics Concept Inventory version 3 administered before and after the course. Participants also completed a 15-item questionnaire documenting student learning characteristics, effort, and confidence. Partial correlations controlling for all other variables in the study, confirmed previous studies that students' grade point average (p < 0.01), interest in biomechanics, (p < 0.05), and physics credits passed (p < 0.05) are factors uniquely associated with learning biomechanics concepts. Students' confidence when encountering difficult biomechanics concepts was also significantly (p < 0.05) associated with final grade. There were significant differences between top 15% and bottom 15% achievers on these variables (p < 0.05), as well as on readings completed, work to pay for college per week, and learning epistemology. Consequently, instructors should consider strategies to promote students' interest in biomechanics and confidence in solving relevant professional problems in order to improve learning for both low- and high-ability students.

  3. Impact of dehydration and fasting on intraocular pressure and corneal biomechanics measured by the Ocular Response Analyzer.

    PubMed

    Uysal, Betul Seher; Duru, Necati; Ozen, Umut; Arikan Yorgun, Mucella; Akcay, Emine; Caglayan, Mehtap; Cagil, Nurullah

    2018-04-01

    To investigate the effects of dehydration and fasting on the intraocular pressure (IOP) and corneal biomechanics during Ramadan in healthy subjects. A total of 36 healthy fasting male volunteers with a mean age of 32.7 ± 5.1 years (range 28-38 years) were enrolled in the study. A Reichert Ocular Response Analyzer (ORA) was used to measure the corneal resistance factor (CRF), corneal hysteresis (CH), Goldman-correlated IOP (IOPg), and corneal-compensated IOP (IOPcc), additionally IOP with Goldmann applanation tonometer (IOP-GAT) was taken. All measurements were recorded at 8:00 am and 4:00 p.m. during Ramadan and during a 1-month follow-up after Ramadan was over. Statistical analysis demonstrated no difference in the ORA measurements including CH, CRF, IOPcc, and IOPg; CCT and CV values between fasting and non-fasting periods or within a single day (diurnal changes). Nine volunteers (25% of total subjects) were excluded because eyedrops were believed to disrupt the Ramadan fast consequently IOP-GAT could not be measured from these subjects. No statistically significant difference was noted between IOP-GAT and IOPg measurements of twenty-seven subjects at the different periods and time points. Our results reveal that fasting during Ramadan does not profoundly affect corneal biomechanics and IOP values in healthy volunteers without ocular diseases such as glaucoma. When planning corneal refractive surgery and determining IOP, the ORA measurements can be done safely during a Ramadan fast. Moreover, ORA may be a better alternative for patients that refuse IOP measurement via GAT for examining the accuracy of IOP during fasting. Further studies are needed to better understand the role of these parameters on corneal disease and glaucoma during fasting.

  4. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  5. History of spine biomechanics: part I--the pre-Greco-Roman, Greco-Roman, and medieval roots of spine biomechanics.

    PubMed

    Naderi, Sait; Andalkar, Niteen; Benzel, Edward C

    2007-02-01

    The roots of spine biomechanics reside in the Antiquity and the Medieval and Renaissance periods. A review of historical treatises reveals detailed information regarding this often historically neglected discipline. Ancient medical, philosophical, and physical documents were reviewed, as they pertained to the historical foundation of spine biomechanics. These included medical case reports and observations of nature and motion by ancient philosophers and scientists. These documents heavily influenced the portion of the scientific literature that we now regard as "spine biomechanics" up through the Renaissance. The focus of Part I of this two-part series is placed on the ancient and medieval biomechanics-related literature and on associated literature that influenced the development of the field of modern spine biomechanics.

  6. Exploring the biomechanics of taurodontism.

    PubMed

    Benazzi, Stefano; Nguyen, Huynh N; Kullmer, Ottmar; Hublin, Jean-Jacques

    2015-02-01

    Taurodontism (i.e. enlarged pulp chamber with concomitant apical displacement of the root bi/trifurcation) is considered a dental anomaly with relatively low incidence in contemporary societies, but it represents a typical trait frequently found in Neandertal teeth. Four hypotheses can be envisioned to explain the high frequency in Neandertals: adaptation to a specific occlusal loading regime (biomechanical advantage), adaptation to a high attrition diet, pleiotropic or genetic drift effects. In this contribution we used finite element analysis (FEA) and advanced loading concepts based on macrowear information to evaluate whether taurodontism supplies some dental biomechanical advantages. Loads were applied to the digital model of the lower right first molar (RM1 ) of the Neandertal specimen Le Moustier 1, as well as to the digital models of both a shortened and a hyper-taurodontic version of Le Moustier RM1 . Moreover, we simulated a scenario where an object is held between teeth and pulled in different directions to investigate whether taurodontism might be useful for para-masticatory activities. Our results do not show any meaningful difference among all the simulations, pointing out that taurodontism does not improve the functional biomechanics of the tooth and does not favour para-masticatory pulling activities. Therefore, taurodontism should be considered either an adaptation to a high attrition diet or most likely the result of pleiotropic or genetic drift effects. Finally, our results have important implications for modern dentistry during endodontic treatments, as we observed that filling the pulp chamber with dentine-like material increases tooth stiffness, and ultimately tensile stresses in the crown, thus favouring tooth failure. © 2014 Anatomical Society.

  7. Current Biomechanical Concepts for Rotator Cuff Repair

    PubMed Central

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  8. [Air transport biomechanical risk: reduced mobility passengers' handling].

    PubMed

    Draicchio, F; Campoli, G; Silvetti, A; Badellino, E; Forzano, F; Ranavolo, A; Iavicoli, S; Campagna, G; Raffaele, G; Gismondi, M

    2012-01-01

    As the airport traffic increases there is a continuous increase of passengers with different motor disabilities. Disabled passenger's assistance causes a biomechanical overload in airport workers. Some disabled passengers are classified by IATA as WCHC (wheel chair in cabin or Charlie). Our study, was performed in one of the most important Italian airport on Charlie passengers (about 10% of all assistances). We identified four critical points: 1) wheelchair and baggage moving (unstable load), 2) inclined ramps with worker's backwards steps and braked wheelchair to prevent passenger tipping or falling, 3) transfer from standard wheelchair to bicycle wheelchair, specifically designed for the aisle; 4.) transfer from bicycle wheelchair to aircraft seat. The last two points required sometimes to lift passengers over the armrest and positioning them on a window side seat, causing a serious increase of biomechanical load. For each critical point we have proposed technical and organizational measures to reduce airport worker's biomechanical risk.

  9. Assessment and characterization of in situ rotator cuff biomechanics

    NASA Astrophysics Data System (ADS)

    Trent, Erika A.; Bailey, Lane; Mefleh, Fuad N.; Raikar, Vipul P.; Shanley, Ellen; Thigpen, Charles A.; Dean, Delphine; Kwartowitz, David M.

    2013-03-01

    Rotator cuff disease is a degenerative disorder that is a common, costly, and often debilitating, ranging in severity from partial thickness tear, which may cause pain, to total rupture, leading to loss in function. Currently, clinical diagnosis and determination of disease extent relies primarily on subjective assessment of pain, range of motion, and possibly X-ray or ultrasound images. The final treatment plan however is at the discretion of the clinician, who often bases their decision on personal experiences, and not quantitative standards. The use of ultrasound for the assessment of tissue biomechanics is established, such as in ultrasound elastography, where soft tissue biomechanics are measured. Few studies have investigated the use of ultrasound elastography in the characterization of musculoskeletal biomechanics. To assess tissue biomechanics we have developed a device, which measures the force applied to the underlying musculotendentious tissue while simultaneously obtaining the related ultrasound images. In this work, the musculotendinous region of the infraspinatus of twenty asymptomatic male organized baseball players was examined to access the variability in tissue properties within a single patient and across a normal population. Elastic moduli at percent strains less than 15 were significantly different than those above 15 percent strain within the normal population. No significant difference in tissue properties was demonstrated within a single patient. This analysis demonstrated elastic moduli are variable across individuals and incidence. Therefore threshold elastic moduli will likely be a function of variation in local-tissue moduli as opposed to a specific global value.

  10. An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.

    PubMed

    Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P

    2017-11-01

    Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P < .001). The footprint coverage of the simple suture and horizontal mattress suture groups was not significantly different ( P = .44). There were no significant differences in load to failure, cyclic displacement, or stiffness between the single-row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was

  11. Changes in fatigue, multiplanar knee laxity, and landing biomechanics during intermittent exercise.

    PubMed

    Shultz, Sandra J; Schmitz, Randy J; Cone, John R; Henson, Robert A; Montgomery, Melissa M; Pye, Michele L; Tritsch, Amanda J

    2015-05-01

    Knee laxity increases during exercise. However, no one, to our knowledge, has examined whether these increases contribute to higher-risk landing biomechanics during prolonged, fatiguing exercise. To examine associations between changes in fatigue (measured as sprint time [SPTIME]), multiplanar knee laxity (anterior-posterior [APLAX], varus-valgus [VVLAX] knee laxity, and internal-external rotation [IERLAX]) knee laxity and landing biomechanics during prolonged, intermittent exercise. Descriptive laboratory study. Laboratory and gymnasium. A total of 30 male (age = 20.3 ± 2.0 years, height = 1.79 ± 0.05 m, mass = 75.2 ± 7.2 kg) and 29 female (age = 20.5 ± 2.3 years, height = 1.67 ± 0.08 m, mass = 61.8 ± 9.0 kg) competitive athletes. A 90-minute intermittent exercise protocol (IEP) designed to simulate the physiologic and biomechanical demands of a soccer match. We measured SPTIME, APLAX, and landing biomechanics before and after warm-up, every 15 minutes during the IEP, and every 15 minutes for 1 hour after the IEP. We measured VVLAX and IERLAX before and after the warm-up, at 45 and 90 minutes during the IEP, and at 30 minutes after the IEP. We used hierarchical linear modeling to examine associations between exercise-related changes in SPTIME and knee laxity with exercise-related changes in landing biomechanics while controlling for initial (before warm-up) knee laxity. We found that SPTIME had a more global effect on landing biomechanics in women than in men, resulting in a more upright landing and a reduction in landing forces and out-of-plane motions about the knee. As APLAX increased with exercise, women increased their knee internal-rotation motion (P = .02), and men increased their hip-flexion motion and energy-absorption (P = .006) and knee-extensor loads (P = .04). As VVLAX and IERLAX increased, women went through greater knee-valgus motion and dorsiflexion and absorbed more energy at the knee (P ≤ .05), whereas men were positioned in greater hip

  12. [The use of open source software in graphic anatomic reconstructions and in biomechanic simulations].

    PubMed

    Ciobanu, O

    2009-01-01

    The objective of this study was to obtain three-dimensional (3D) images and to perform biomechanical simulations starting from DICOM images obtained by computed tomography (CT). Open source software were used to prepare digitized 2D images of tissue sections and to create 3D reconstruction from the segmented structures. Finally, 3D images were used in open source software in order to perform biomechanic simulations. This study demonstrates the applicability and feasibility of open source software developed in our days for the 3D reconstruction and biomechanic simulation. The use of open source software may improve the efficiency of investments in imaging technologies and in CAD/CAM technologies for implants and prosthesis fabrication which need expensive specialized software.

  13. Biomechanics of Single Cortical Neurons

    PubMed Central

    Bernick, Kristin B.; Prevost, Thibault P.; Suresh, Subra; Socrate, Simona

    2011-01-01

    This study presents experimental results and computational analysis of the large strain dynamic behavior of single neurons in vitro with the objective of formulating a novel quantitative framework for the biomechanics of cortical neurons. Relying on the atomic force microscopy (AFM) technique, novel testing protocols are developed to enable the characterization of neural soma deformability over a range of indentation rates spanning three orders of magnitude – 10, 1, and 0.1 μm/s. Modified spherical AFM probes were utilized to compress the cell bodies of neonatal rat cortical neurons in load, unload, reload and relaxation conditions. The cell response showed marked hysteretic features, strong non-linearities, and substantial time/rate dependencies. The rheological data were complemented with geometrical measurements of cell body morphology, i.e. cross-diameter and height estimates. A constitutive model, validated by the present experiments, is proposed to quantify the mechanical behavior of cortical neurons. The model aimed to correlate empirical findings with measurable degrees of (hyper-) elastic resilience and viscosity at the cell level. The proposed formulation, predicated upon previous constitutive model developments undertaken at the cortical tissue level, was implemented into a three-dimensional finite element framework. The simulated cell response was calibrated to the experimental measurements under the selected test conditions, providing a novel single cell model that could form the basis for further refinements. PMID:20971217

  14. Kinesiology/Biomechanics: Perspectives and Trends.

    ERIC Educational Resources Information Center

    Atwater, Anne E.

    1980-01-01

    Past and recent developments and future directions in kinesiology and biomechanics are reviewed. Similarities and differences between these two areas are clarified. The areas of kinesiology and biomechanics have distinct unique qualities and should be treated as separate disciplines. (CJ)

  15. Improving Objective Measures of Mobility.

    ERIC Educational Resources Information Center

    Dodds, Allan G.; And Others

    1983-01-01

    The article examines shortcomings in existing objective measures of mobility for blind persons in the light of evaluative experiences and demonstrates improvements in reliability, together with a new technique for tracking pavement position. It refutes the idea that it is not possible to measure improvement in performance objectively. (Author/CL)

  16. Effects of Aging on the Biomechanics of Slips and Falls

    PubMed Central

    Lockhart, Thurmon E.; Smith, James L.; Woldstad, Jeffrey C.

    2010-01-01

    Although much has been learned in recent decades about the deterioration of muscular strength, gait adaptations, and sensory degradation among older adults, little is known about how these intrinsic changes affect biomechanical parameters associated with slip-induced fall accidents. In general, the objective of this laboratory study was to investigate the process of initiation, detection, and recovery of inadvertent slips and falls. We examined the initiation of and recovery from foot slips among three age groups utilizing biomechanical parameters, muscle strength, and sensory measurements. Forty-two young, middle-age, and older participants walked around a walking track at a comfortable pace. Slippery floor surfaces were placed on the track over force platforms at random intervals without the participants’ awareness. Results indicated that younger participants slipped as often as the older participants, suggesting that the likelihood of slip initiation is similar across all age groups; however, older individuals’ recovery process was much slower and less effective. The ability to successfully recover from a slip (thus preventing a fall) is believed to be affected by lower extremity muscle strength and sensory degradation among older individuals. Results from this research can help pinpoint possible intervention strategies for improving dynamic equilibrium among older adults. PMID:16553061

  17. Biomechanics of Sports-Induced Axial-Compression Injuries of the Neck

    PubMed Central

    Ivancic, Paul C.

    2012-01-01

    Context Head-first sports-induced impacts cause cervical fractures and dislocations and spinal cord lesions. In previous biomechanical studies, researchers have vertically dropped human cadavers, head-neck specimens, or surrogate models in inverted postures. Objective To develop a cadaveric neck model to simulate horizontally aligned, head-first impacts with a straightened neck and to use the model to investigate biomechanical responses and failure mechanisms. Design Descriptive laboratory study. Setting Biomechanics research laboratory. Patients or Other Participants Five human cadaveric cervical spine specimens. Intervention(s) The model consisted of the neck specimen mounted horizontally to a torso-equivalent mass on a sled and carrying a surrogate head. Head-first impacts were simulated at 4.1 m/s into a padded, deformable barrier. Main Outcome Measure(s) Time-history responses were determined for head and neck loads, accelerations, and motions. Average occurrence times of the compression force peaks at the impact barrier, occipital condyles, and neck were compared. Results The first local compression force peaks at the impact barrier (3070.0 ± 168.0 N at 18.8 milliseconds), occipital condyles (2868.1 ± 732.4 N at 19.6 milliseconds), and neck (2884.6 ± 910.7 N at 25.0 milliseconds) occurred earlier than all global compression peaks, which reached 7531.6 N in the neck at 46.6 milliseconds (P < .001). Average peak head motions relative to the torso were 6.0 cm in compression, 2.4 cm in posterior shear, and 6.4° in flexion. Neck compression fractures included occipital condyle, atlas, odontoid, and subaxial comminuted burst and facet fractures. Conclusions Neck injuries due to excessive axial compression occurred within 20 milliseconds of impact and were caused by abrupt deceleration of the head and continued forward torso momentum before simultaneous rebound of the head and torso. Improved understanding of neck injury mechanisms during sports-induced impacts

  18. Investigation of Crew Restraint System Biomechanics.

    DTIC Science & Technology

    1982-05-01

    46FAMRL-TR-81 -103 SINVESTIGATION OF CREW RESTRAINT SYSTEM BIOMECHANICS NORMWAN S. PHILLIPS ROBERT A. THOMSON IRA B. FISCUS UNIVERSITY OF DA YTON RESEARCH...Escape System Biomechanics 20. ABSTRACT (Continue on reverse side If necessary and identify by block number) .Experimental data were collected and...properties and harness characteristics were included in the model. The analytical model was also used with biomechanical data for the rhesus monkey

  19. Mathematical foundations of biomechanics.

    PubMed

    Niederer, Peter F

    2010-01-01

    The aim of biomechanics is the analysis of the structure and function of humans, animals, and plants by means of the methods of mechanics. Its foundations are in particular embedded in mathematics, physics, and informatics. Due to the inherent multidisciplinary character deriving from its aim, biomechanics has numerous connections and overlapping areas with biology, biochemistry, physiology, and pathophysiology, along with clinical medicine, so its range is enormously wide. This treatise is mainly meant to serve as an introduction and overview for readers and students who intend to acquire a basic understanding of the mathematical principles and mechanics that constitute the foundation of biomechanics; accordingly, its contents are limited to basic theoretical principles of general validity and long-range significance. Selected examples are included that are representative for the problems treated in biomechanics. Although ultimate mathematical generality is not in the foreground, an attempt is made to derive the theory from basic principles. A concise and systematic formulation is thereby intended with the aim that the reader is provided with a working knowledge. It is assumed that he or she is familiar with the principles of calculus, vector analysis, and linear algebra.

  20. Relationships between age at menarche, walking gait base of support, and stance phase frontal plane knee biomechanics in adolescent females

    PubMed Central

    Grannis, Kimberly A.; Sherwood, Richard J.; Duren, Dana L

    2016-01-01

    Background Age at menarche impacts patterns of pubertal growth and skeletal development. These effects may carry over into variation in biomechanical profiles involved in sports-related traumatic and overuse knee injuries. The present study investigated whether age at menarche is a potential indicator of knee injury risk through its influence on knee biomechanics during normal walking. Objective To test the hypothesis that earlier menarche is related to post-pubertal biomechanical risk factors for knee injuries, including a wider, more immature gait base of support, and greater valgus knee angles and moments. Design Cross-sectional observational study. Setting University research facility. Participants Healthy, post-menarcheal, adolescent females. Methods Age at menarche was obtained by recall questionnaire. Pubertal growth and anthropometric data were collected using standard methods. Biomechanical data were taken from tests of walking gait at self-selected speed. Reflective marker position data were collected using a three-dimensional quantitative motion analysis system, and three force plates recorded kinetic data. Main Outcome Measures Age at menarche; growth and anthropometric measurements; base of support; static knee frontal plane angle; dynamic knee frontal plane angles and moments during stance. Results Earlier menarche was significantly correlated with abbreviated pubertal growth and post-pubertal retention of immature traits, including a wider base of support. Earlier menarche and wider base of support were both correlated with more valgus static knee angles, more valgus knee abduction angles and moments at foot-strike, and a more valgus peak knee abduction angle during stance. Peak knee abduction moment during stance was not correlated with age at menarche or base of support. Conclusions Earlier menarche and its effects on growth are associated with retention of a relatively immature gait base of support and a tendency for static and dynamic valgus knee

  1. Using inertial measurement units originally developed for biomechanics for modal testing of civil engineering structures

    NASA Astrophysics Data System (ADS)

    Hester, David; Brownjohn, James; Bocian, Mateusz; Xu, Yan; Quattrone, Antonino

    2018-05-01

    This paper explores the use of wireless Inertial Measurement Units (IMU) originally developed for bio-mechanical research applications for modal testing of civil engineering infrastructure. Due to their biomechanics origin, these devices combine a triaxial accelerometer with gyroscopes and magnetometers for orientation, as well as on board data logging capability and wireless communication for optional data streaming and to coordinate synchronisation with other IMUs in a network. The motivation for application to civil structures is that their capabilities and simple operating procedures make them suitable for modal testing of many types of civil infrastructure of limited dimension including footbridges and floors while also enabling recovering of dynamic forces generated and applied to structures by moving humans. To explore their capabilities in civil applications, the IMUs are evaluated through modal tests on three different structures with increasing challenge of spatial and environmental complexity. These are, a full-scale floor mock-up in a laboratory, a short span road bridge and a seven story office tower. For each case, the results from the IMUs are compared with those from a conventional wired system to identify the limitations. The main conclusion is that the relatively high noise floor and limited communication range will not be a serious limitation in the great majority of typical civil modal test applications where convenient operation is a significant advantage over conventional wired systems.

  2. Tree Branching: Leonardo da Vinci's Rule versus Biomechanical Models

    PubMed Central

    Minamino, Ryoko; Tateno, Masaki

    2014-01-01

    This study examined Leonardo da Vinci's rule (i.e., the sum of the cross-sectional area of all tree branches above a branching point at any height is equal to the cross-sectional area of the trunk or the branch immediately below the branching point) using simulations based on two biomechanical models: the uniform stress and elastic similarity models. Model calculations of the daughter/mother ratio (i.e., the ratio of the total cross-sectional area of the daughter branches to the cross-sectional area of the mother branch at the branching point) showed that both biomechanical models agreed with da Vinci's rule when the branching angles of daughter branches and the weights of lateral daughter branches were small; however, the models deviated from da Vinci's rule as the weights and/or the branching angles of lateral daughter branches increased. The calculated values of the two models were largely similar but differed in some ways. Field measurements of Fagus crenata and Abies homolepis also fit this trend, wherein models deviated from da Vinci's rule with increasing relative weights of lateral daughter branches. However, this deviation was small for a branching pattern in nature, where empirical measurements were taken under realistic measurement conditions; thus, da Vinci's rule did not critically contradict the biomechanical models in the case of real branching patterns, though the model calculations described the contradiction between da Vinci's rule and the biomechanical models. The field data for Fagus crenata fit the uniform stress model best, indicating that stress uniformity is the key constraint of branch morphology in Fagus crenata rather than elastic similarity or da Vinci's rule. On the other hand, mechanical constraints are not necessarily significant in the morphology of Abies homolepis branches, depending on the number of daughter branches. Rather, these branches were often in agreement with da Vinci's rule. PMID:24714065

  3. Tree branching: Leonardo da Vinci's rule versus biomechanical models.

    PubMed

    Minamino, Ryoko; Tateno, Masaki

    2014-01-01

    This study examined Leonardo da Vinci's rule (i.e., the sum of the cross-sectional area of all tree branches above a branching point at any height is equal to the cross-sectional area of the trunk or the branch immediately below the branching point) using simulations based on two biomechanical models: the uniform stress and elastic similarity models. Model calculations of the daughter/mother ratio (i.e., the ratio of the total cross-sectional area of the daughter branches to the cross-sectional area of the mother branch at the branching point) showed that both biomechanical models agreed with da Vinci's rule when the branching angles of daughter branches and the weights of lateral daughter branches were small; however, the models deviated from da Vinci's rule as the weights and/or the branching angles of lateral daughter branches increased. The calculated values of the two models were largely similar but differed in some ways. Field measurements of Fagus crenata and Abies homolepis also fit this trend, wherein models deviated from da Vinci's rule with increasing relative weights of lateral daughter branches. However, this deviation was small for a branching pattern in nature, where empirical measurements were taken under realistic measurement conditions; thus, da Vinci's rule did not critically contradict the biomechanical models in the case of real branching patterns, though the model calculations described the contradiction between da Vinci's rule and the biomechanical models. The field data for Fagus crenata fit the uniform stress model best, indicating that stress uniformity is the key constraint of branch morphology in Fagus crenata rather than elastic similarity or da Vinci's rule. On the other hand, mechanical constraints are not necessarily significant in the morphology of Abies homolepis branches, depending on the number of daughter branches. Rather, these branches were often in agreement with da Vinci's rule.

  4. Vesicle biomechanics in a time-varying magnetic field.

    PubMed

    Ye, Hui; Curcuru, Austen

    2015-01-01

    Cells exhibit distortion when exposed to a strong electric field, suggesting that the field imposes control over cellular biomechanics. Closed pure lipid bilayer membranes (vesicles) have been widely used for the experimental and theoretical studies of cellular biomechanics under this electrodeformation. An alternative method used to generate an electric field is by electromagnetic induction with a time-varying magnetic field. References reporting the magnetic control of cellular mechanics have recently emerged. However, theoretical analysis of the cellular mechanics under a time-varying magnetic field is inadequate. We developed an analytical theory to investigate the biomechanics of a modeled vesicle under a time-varying magnetic field. Following previous publications and to simplify the calculation, this model treated the inner and suspending media as lossy dielectrics, the membrane thickness set at zero, and the electric resistance of the membrane assumed to be negligible. This work provided the first analytical solutions for the surface charges, electric field, radial pressure, overall translational forces, and rotational torques introduced on a vesicle by the time-varying magnetic field. Frequency responses of these measures were analyzed, particularly the frequency used clinically by transcranial magnetic stimulation (TMS). The induced surface charges interacted with the electric field to produce a biomechanical impact upon the vesicle. The distribution of the induced surface charges depended on the orientation of the coil and field frequency. The densities of these charges were trivial at low frequency ranges, but significant at high frequency ranges. The direction of the radial force on the vesicle was dependent on the conductivity ratio between the vesicle and the medium. At relatively low frequencies (<200 KHz), including the frequency used in TMS, the computed radial pressure and translational forces on the vesicle were both negligible. This work

  5. A motor learning approach to training wheelchair propulsion biomechanics for new manual wheelchair users: A pilot study

    PubMed Central

    Morgan, Kerri A.; Tucker, Susan M.; Klaesner, Joseph W.; Engsberg, Jack R.

    2017-01-01

    Context/Objective Developing an evidence-based approach to teaching wheelchair skills and proper propulsion for everyday wheelchair users with a spinal cord injury (SCI) is important to their rehabilitation. The purpose of this project was to pilot test manual wheelchair training based on motor learning and repetition-based approaches for new manual wheelchair users with an SCI. Design A repeated measures within-subject design was used with participants acting as their own controls. Methods Six persons with an SCI requiring the use of a manual wheelchair participated in wheelchair training. The training included nine 90-minute sessions. The primary focus was on wheelchair propulsion biomechanics with a secondary focus on wheelchair skills. Outcome Measures During Pretest 1, Pretest 2, and Posttest, wheelchair propulsion biomechanics were measured using the Wheelchair Propulsion Test and a Video Motion Capture system. During Pretest 2 and Posttest, propulsion forces using the WheelMill System and wheelchair skills using the Wheelchair Skills Test were measured. Results Significant changes in area of the push loop, hand-to-axle relationship, and slope of push forces were found. Changes in propulsion patterns were identified post-training. No significant differences were found in peak and average push forces and wheelchair skills pre- and post-training. Conclusions This project identified trends in change related to a repetition-based motor learning approach for propelling a manual wheelchair. The changes found were related to the propulsion patterns used by participants. Despite some challenges associated with implementing interventions for new manual wheelchair users, such as recruitment, the results of this study show that repetition-based training can improve biomechanics and propulsion patterns for new manual wheelchair users. PMID:26674751

  6. Recent software developments for biomechanical assessment

    NASA Astrophysics Data System (ADS)

    Greaves, John O. B.

    1990-08-01

    While much of the software developed in research laboratories is narrow in focus and suited for a specific experiment, some of it is broad enough and of high enough quality to be useful to others in solving similar problems. Several biomechanical assessment packages are now beginning to emerge, including: * 3D research biomechanics (5- and 6-DOF) with kinematics, kinetics, 32-channel analog data subsystem, and project management. * 3D full-body gait analysis with kinematics, kinetics, EMG charts, and force plate charts. * 2D dynamic rear-foot assessment. * 2D occupational biomechanics lifting task and personnel assessments. * 2D dynamic gait analysis. * Multiple 2D dynamic spine assessments. * 2D sport and biomechanics assessments with kinematics and kinetics. * 2D and 3D equine gait assessments.

  7. Biomechanical factors associated with time to complete a change of direction cutting maneuver.

    PubMed

    Marshall, Brendan M; Franklyn-Miller, Andrew D; King, Enda A; Moran, Kieran A; Strike, Siobhán C; Falvey, Éanna C

    2014-10-01

    Cutting ability is an important aspect of many team sports, however, the biomechanical determinants of cutting performance are not well understood. This study aimed to address this issue by identifying the kinetic and kinematic factors correlated with the time to complete a cutting maneuver. In addition, an analysis of the test-retest reliability of all biomechanical measures was performed. Fifteen (n = 15) elite multidirectional sports players (Gaelic hurling) were recruited, and a 3-dimensional motion capture analysis of a 75° cut was undertaken. The factors associated with cutting time were determined using bivariate Pearson's correlations. Intraclass correlation coefficients (ICCs) were used to examine the test-retest reliability of biomechanical measures. Five biomechanical factors were associated with cutting time (2.28 ± 0.11 seconds): peak ankle power (r = 0.77), peak ankle plantar flexor moment (r = 0.65), range of pelvis lateral tilt (r = -0.54), maximum thorax lateral rotation angle (r = 0.51), and total ground contact time (r = -0.48). Intraclass correlation coefficient scores for these 5 factors, and indeed for the majority of the other biomechanical measures, ranged from good to excellent (ICC >0.60). Explosive force production about the ankle, pelvic control during single-limb support, and torso rotation toward the desired direction of travel were all key factors associated with cutting time. These findings should assist in the development of more effective training programs aimed at improving similar cutting performances. In addition, test-retest reliability scores were generally strong, therefore, motion capture techniques seem well placed to further investigate the determinants of cutting ability.

  8. A Taxonomy of Object-Oriented Measures Modeling the Object-Oriented Space

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.; Weistroffer, H. Roland; Coppins, Richard J.

    1997-01-01

    In order to control the quality of software and the software development process, it is important to understand the measurement of software. A first step toward a better comprehension of software measurement is the categorization of software measures by some meaningful taxonomy. The most worthwhile taxonomy would capture the fundamental nature of the object-oriented (O-O) space. The principal characteristics of object-oriented software offer a starting point for such a categorization of measures. This paper introduces a taxonomy of measures based upon fourteen characteristics of object-oriented software gathered from the literature. This taxonomy allows us to easily see gaps or redundancies in the existing O-O measures. The taxonomy also clearly differentiates among taxa so that there is no ambiguity as to the taxon to which a measure belongs. The taxonomy has been populated with measures taken from the literature.

  9. A Taxonomy of Object-Oriented Measures Modeling the Object Oriented Space

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.; Weistroffer, H. Roland; Coppins, Richard J.

    1997-01-01

    In order to control the quality of software and the software development process, it is important to understand the measurement of software. A first step toward a better comprehension of software measurement is the categorization of software measures by some meaningful taxonomy. The most worthwhile taxonomy would capture the fundamental nature of the object-oriented (O-O) space. The principal characteristics of object-oriented software offer a starting point for such a categorization of measures. This paper introduces a taxonomy of measures based upon fourteen characteristics of object-oriented software gathered from the literature. This taxonomy allows us to easily see gaps or redundancies in the existing O-O measures. The taxonomy also clearly differentiates among taxa so that there is no ambiguity as to the taxon to which a measure belongs. The taxonomy has been populated with measures taken from the literature.

  10. Biomechanical Comparison: Single-Bundle versus Double-Bundle Posterior Cruciate Ligament Reconstruction Techniques.

    PubMed

    Milles, Jeffrey L; Nuelle, Clayton W; Pfeiffer, Ferris; Stannard, James P; Smith, Patrick; Kfuri, Mauricio; Cook, James L

    2017-05-01

    Controversy exists regarding double-bundle (DB) versus single-bundle (SB) posterior cruciate ligament (PCL) reconstruction, with differences in multiple variables affecting biomechanical and clinical results. Our objective was to compare immediate postimplantation biomechanics of SB versus DB reconstructions to determine the relative importance of restoring both PCL bundles versus total graft volume. Twenty knees were randomly assigned to five techniques ( n  = 4 knees/technique), performed by three surgeons experienced in their technique(s), three SB techniques ( n  = 12; all-inside arthroscopic inlay, all-inside suspensory fixation, and arthroscopic-assisted open onlay), and two DB techniques ( n  = 8; arthroscopic-assisted open inlay and all-inside suspensory fixation). Each knee was tested in three conditions: PCL-intact, PCL-deficient, and post-PCL reconstruction. Testing consisted of a posterior-directed force at four knee flexion angles, 10, 30, 60, and 90 degrees, to measure load to 5 mm of posterior displacement, maximum displacement (at 100 N load), and stiffness. Data for each knee were normalized, combined into two groups (SB and DB), and then compared using one-way analysis of variance. Graft volumes were calculated and analyzed to determine if differences significantly influenced the biomechanical results. Intact knees were stiffer than both groups at most angles ( p  < 0.02; p  < 0.05). DB was stiffer than SB at all angles except 30 degrees ( p  < 0.05). Intact knees had less laxity than SB ( p  < 0.03) and DB ( p  < 0.05) at 60 and 90 degrees. DB had less laxity than SB at all angles except 60 degrees ( p  < 0.05). Intact knees required more load than SB at 30, 60, and 90 degrees ( p  < 0.01) and more than DB at 60 and 90 degrees ( p  < 0.05). DB required more load than SB at 30, 60, and 90 degrees ( p  < 0.01). Graft volumes did not have strong correlations ( r  = 0.13-0.37) to any

  11. 4th International Plant Biomechanics Conference Proceedings (Abstracts)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frank W. Telewski; Lothar H. Koehler; Frank W. Ewers

    2003-07-20

    The 4th International Plant Biomechanics Conference facilitated an interdisciplinary exchange between scientists, engineers, and educators addressing the major questions encountered in the field of Plant Biomechanics. Subjects covered by the conference include: Evolution; Ecology; Mechanoreception; Cell Walls; Genetic Modification; Applied Biomechanics of Whole Plants, Plant Products, Fibers & Composites; Fluid Dynamics; Wood & Trees; Fracture Mechanics; Xylem Pressure & Water Transport; Modeling; and Introducing Plant Biomechanics in Secondary School Education.

  12. In vitro determination of biomechanical properties of human articular cartilage in osteoarthritis using multi-parametric MRI

    NASA Astrophysics Data System (ADS)

    Juras, Vladimir; Bittsansky, Michal; Majdisova, Zuzana; Szomolanyi, Pavol; Sulzbacher, Irene; Gäbler, Stefan; Stampfl, Jürgen; Schüller, Georg; Trattnig, Siegfried

    2009-03-01

    The objective of this study was to evaluate the correlations between MR parameters and the biomechanical properties of naturally degenerated human articular cartilage. Human cartilage explants from the femoral condyles of patients who underwent total knee replacement were evaluated on a micro-imaging system at 3 T. To quantify glycosaminoglycan (GAG) content, delayed gadolinium-enhanced MRI of the cartilage (dGEMRIC) was used. T2 maps were created by using multi-echo, multi-slice spin echo sequences with six echoes: 15, 30, 45, 60, 75, and 90 ms. Data for apparent diffusion constant (ADC) maps were obtained from pulsed gradient spin echo (PGSE) sequences with five b-values: 10.472, 220.0, 627.0, 452.8, 724.5, and 957.7. MR parameters were correlated with mechanical parameters (instantaneous ( I) and equilibrium ( Eq) modulus and relaxation time ( τ)), and the OA stage of each cartilage specimen was determined by histological evaluation of hematoxylin-eosin stained slices. For some parameters, a high correlation was found: the correlation of T1Gd vs Eq ( r = 0.8095), T1Gd vs I/ Eq ( r = -0.8441) and T1Gd vs τ ( r = 0.8469). The correlation of T2 and ADC with selected biomechanical parameters was not statistically significant. In conclusion, GAG content measured by dGEMRIC is highly related to the selected biomechanical properties of naturally degenerated articular cartilage. In contrast, T2 and ADC were unable to estimate these properties. The results of the study imply that some MR parameters can non-invasively predict the biomechanical properties of degenerated articular cartilage.

  13. Authorship and sampling practice in selected biomechanics and sports science journals.

    PubMed

    Knudson, Duane V

    2011-06-01

    In some biomedical sciences, changes in patterns of collaboration and authorship have complicated the assignment of credit and responsibility for research. It is unclear if this problem of "promiscuous coauthorship" or "hyperauthorship" (defined as six or more authors) is also apparent in the applied research disciplines within sport and exercise science. This study documented the authorship and sampling of patterns of original research reports in three applied biomechanics (Clinical Biomechanics, Journal of Applied Biomechanics, and Sports Biomechanics) and five similar subdisciplinary journals within sport and exercise science (International Journal of Sports Physiology and Performance, Journal of Sport Rehabilitation, Journal of Teaching Physical Education, Measurement in Physical Education and Exercise Sciences, and Motor Control). Original research reports from the 2009 volumes of these biomechanics and sport and exercise journals were reviewed. Single authorship of papers was rare (2.6%) in these journals, with the mean number of authors ranging from 2.7 to 4.5. Sample sizes and the ratio of sample to authors varied widely, and these variables tended not to be associated with number of authors. Original research reports published in these journals in 2009 tended to be published by small teams of collaborators, so currently there may be few problems with promiscuous coauthorship in these subdisciplines of sport and exercise science.

  14. Influence of TRAIL gene on biomechanical properties of the human leukemic cell line Jurkat.

    PubMed

    Yao, Weijuan; Chen, Kai; Wang, Xinjuan; Xie, Lide; Wen, Zongyao; Yan, Zongyi; Chien, Shu

    2002-12-01

    We cloned the cDNA fragment of human TNF-related apoptosis inducing ligand (TRAIL) into RevTet-On, a Tet-regulated and high-level gene expression system. Making use of the TRAIL gene expression system in Jurkat as a cell model, we studied the influence of TRAIL gene on the biomechanics properties of Jurkat through measuring changes of cellular biomechanics properties before and after the TRAIL gene expression, which was induced by adding tetracycline derivative doxycycline (Dox). The results indicated that the TRAIL gene expression led to significant changes in cellular biomechanics properties. The osmotic fragility increased and the cell stiffness increased after the expression of TRAIL gene. Thus, the apoptosis-inducing TRAIL gene caused significant changes in the biomechanics properties of Jurkat cells.

  15. Hand Rim Wheelchair Propulsion Training Using Biomechanical Real-Time Visual Feedback Based on Motor Learning Theory Principles

    PubMed Central

    Rice, Ian; Gagnon, Dany; Gallagher, Jere; Boninger, Michael

    2010-01-01

    Background/Objective: As considerable progress has been made in laboratory-based assessment of manual wheelchair propulsion biomechanics, the necessity to translate this knowledge into new clinical tools and treatment programs becomes imperative. The objective of this study was to describe the development of a manual wheelchair propulsion training program aimed to promote the development of an efficient propulsion technique among long-term manual wheelchair users. Methods: Motor learning theory principles were applied to the design of biomechanical feedback-based learning software, which allows for random discontinuous real-time visual presentation of key spatio-temporal and kinetic parameters. This software was used to train a long-term wheelchair user on a dynamometer during 3 low-intensity wheelchair propulsion training sessions over a 3-week period. Biomechanical measures were recorded with a SmartWheel during over ground propulsion on a 50-m level tile surface at baseline and 3 months after baseline. Results: Training software was refined and administered to a participant who was able to improve his propulsion technique by increasing contact angle while simultaneously reducing stroke cadence, mean resultant force, peak and mean moment out of plane, and peak rate of rise of force applied to the pushrim after training. Conclusions: The proposed propulsion training protocol may lead to favorable changes in manual wheelchair propulsion technique. These changes could limit or prevent upper limb injuries among manual wheelchair users. In addition, many of the motor learning theory–based techniques examined in this study could be applied to training individuals in various stages of rehabilitation to optimize propulsion early on. PMID:20397442

  16. FEBio: finite elements for biomechanics.

    PubMed

    Maas, Steve A; Ellis, Benjamin J; Ateshian, Gerard A; Weiss, Jeffrey A

    2012-01-01

    In the field of computational biomechanics, investigators have primarily used commercial software that is neither geared toward biological applications nor sufficiently flexible to follow the latest developments in the field. This lack of a tailored software environment has hampered research progress, as well as dissemination of models and results. To address these issues, we developed the FEBio software suite (http://mrl.sci.utah.edu/software/febio), a nonlinear implicit finite element (FE) framework, designed specifically for analysis in computational solid biomechanics. This paper provides an overview of the theoretical basis of FEBio and its main features. FEBio offers modeling scenarios, constitutive models, and boundary conditions, which are relevant to numerous applications in biomechanics. The open-source FEBio software is written in C++, with particular attention to scalar and parallel performance on modern computer architectures. Software verification is a large part of the development and maintenance of FEBio, and to demonstrate the general approach, the description and results of several problems from the FEBio Verification Suite are presented and compared to analytical solutions or results from other established and verified FE codes. An additional simulation is described that illustrates the application of FEBio to a research problem in biomechanics. Together with the pre- and postprocessing software PREVIEW and POSTVIEW, FEBio provides a tailored solution for research and development in computational biomechanics.

  17. Computational biomechanics changes our view on insect head evolution.

    PubMed

    Blanke, Alexander; Watson, Peter J; Holbrey, Richard; Fagan, Michael J

    2017-02-08

    Despite large-scale molecular attempts, the relationships of the basal winged insect lineages dragonflies, mayflies and neopterans, are still unresolved. Other data sources, such as morphology, suffer from unclear functional dependencies of the structures considered, which might mislead phylogenetic inference. Here, we assess this problem by combining for the first time biomechanics with phylogenetics using two advanced engineering techniques, multibody dynamics analysis and finite-element analysis, to objectively identify functional linkages in insect head structures which have been used traditionally to argue basal winged insect relationships. With a biomechanical model of unprecedented detail, we are able to investigate the mechanics of morphological characters under biologically realistic load, i.e. biting. We show that a range of head characters, mainly ridges, endoskeletal elements and joints, are indeed mechanically linked to each other. An analysis of character state correlation in a morphological data matrix focused on head characters shows highly significant correlation of these mechanically linked structures. Phylogenetic tree reconstruction under different data exclusion schemes based on the correlation analysis unambiguously supports a sistergroup relationship of dragonflies and mayflies. The combination of biomechanics and phylogenetics as it is proposed here could be a promising approach to assess functional dependencies in many organisms to increase our understanding of phenotypic evolution. © 2017 The Author(s).

  18. Hamstrings Stiffness and Landing Biomechanics Linked to Anterior Cruciate Ligament Loading

    PubMed Central

    Blackburn, J. Troy; Norcross, Marc F.; Cannon, Lindsey N.; Zinder, Steven M.

    2013-01-01

    Context: Greater hamstrings stiffness is associated with less anterior tibial translation during controlled perturbations. However, it is unclear how hamstrings stiffness influences anterior cruciate ligament (ACL) loading mechanisms during dynamic tasks. Objective: To evaluate the influence of hamstrings stiffness on landing biomechanics related to ACL injury. Design: Cross-sectional study. Setting: Research laboratory. Patients or Other Participants: A total of 36 healthy, physically active volunteers (18 men, 18 women; age = 23 ± 3 years, height = 1.8 ± 0.1 m, mass = 73.1 ± 16.6 kg). Intervention(s): Hamstrings stiffness was quantified via the damped oscillatory technique. Three-dimensional lower extremity kinematics and kinetics were captured during a double-legged jump-landing task via a 3-dimensional motion-capture system interfaced with a force plate. Landing biomechanics were compared between groups displaying high and low hamstrings stiffness via independent-samples t tests. Main Outcome Measure(s): Hamstrings stiffness was normalized to body mass (N/m·kg−1). Peak knee-flexion and -valgus angles, vertical and posterior ground reaction forces, anterior tibial shear force, internal knee-extension and -varus moments, and knee-flexion angles at the instants of each peak kinetic variable were identified during the landing task. Forces were normalized to body weight, whereas moments were normalized to the product of weight and height. Results: Internal knee-varus moment was 3.6 times smaller in the high-stiffness group (t22 = 2.221, P = .02). A trend in the data also indicated that peak anterior tibial shear force was 1.1 times smaller in the high-stiffness group (t22 = 1.537, P = .07). The high-stiffness group also demonstrated greater knee flexion at the instants of peak anterior tibial shear force and internal knee-extension and -varus moments (t22 range = 1.729–2.224, P < .05). Conclusions: Greater hamstrings stiffness was associated with landing

  19. A portable system for foot biomechanical analysis during gait.

    PubMed

    Samson, William; Sanchez, Stéphane; Salvia, Patrick; Jan, Serge Van Sint; Feipel, Véronique

    2014-07-01

    Modeling the foot is challenging due to its complex structure compared to most other body segments. To analyze the biomechanics of the foot, portable devices have been designed to allow measurement of temporal, spatial, and pedobarographic parameters. The goal of this study was to design and evaluate a portable system for kinematic and dynamic analysis of the foot during gait. This device consisted of a force plate synchronized with four cameras and integrated into a walkway. The complete system can be packaged for transportation. First, the measurement system was assessed using reference objects to evaluate accuracy and precision. Second, nine healthy participants were assessed during gait trials using both the portable and Vicon systems (coupled with a force plate). The ankle and metatarsophalangeal (MP) joint angles and moments were computed, as well as the ground reaction force (GRF). The intra- and inter-subject variability was analyzed for both systems, as well as the inter-system variation. The accuracy and precision were, respectively 0.4 mm and 0.4 mm for linear values and 0.5° and 0.6° for angular values. The variability of the portable and Vicon systems were similar (i.e., the inter-system variability never exceeded 2.1°, 0.081 Nmkg(-1) and 0.267 Nkg(-1) for the angles, moments and GRF, respectively). The inter-system differences were less than the inter-subject variability and similar to the intra-subject variability. Consequently, the portable system was considered satisfactory for biomechanical analysis of the foot, outside of a motion analysis laboratory. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Biomechanical properties of the forefoot plantar soft tissue as measured by an optical coherence tomography-based air-jet indentation system and tissue ultrasound palpation system.

    PubMed

    Chao, Clare Y L; Zheng, Yong-Ping; Huang, Yan-Ping; Cheing, Gladys L Y

    2010-07-01

    The forefoot medial plantar area withstand high plantar pressure during locomotion, and is a common site that develops foot lesion problems among elderly people. The aims of the present study were to (1) determine the correlation between the biomechanical properties of forefoot medial plantar soft tissue measured by a newly developed optical coherence tomography-based air-jet indentation system and by tissue ultrasound palpation system, and (2) to compare the biomechanical properties of plantar soft tissues of medial forefoot between a young and old adult group. Thirty healthy subjects were classified as the young or older group. The biomechanical properties of plantar soft tissues measured at the forefoot by the air-jet indentation system and tissue ultrasound palpation system were performed, and the correlation of the findings obtained in the two systems were compared. A strong positive correlation was obtained from the findings in the two systems (r=0.88, P<0.001). The forefoot plantar soft tissue of the older group was significantly stiffer at the second metatarsal head and thinner at both metatarsal heads than that of the young group (all P<0.05). The stiffness coefficient at the second metatarsal head was 28% greater than that at the first metatarsal head in both study groups. Older subjects showed a loss of elasticity and reduced thickness in their forefoot plantar soft tissue, with the second metatarsal head displaying stiffer and thicker plantar tissue than the first metatarsal head. The air-jet indentation system is a useful instrument for characterizing the biomechanical properties of soft tissue. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  1. Biomechanics in dermatology: Recent advances and future directions.

    PubMed

    Lewinson, Ryan T; Haber, Richard M

    2017-02-01

    Biomechanics is increasingly being recognized as an important research area in dermatology. To highlight only a few examples, biomechanics has contributed to the development of novel topical therapies for aesthetic and medical purposes, enhanced our understanding of the pathogenesis of plantar melanoma, and provided insight into the epidemiology of psoriatic disease. This article summarizes the findings from recent studies to demonstrate the important role that biomechanics may have in dermatologic disease and therapy and places these biomechanical findings in a clinical context for the practicing physician. In addition, areas for future biomechanics research and development in dermatology are discussed. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  2. The biomechanics of forward power skating.

    PubMed

    Humble, R N; Gastwirth, B W

    1988-04-01

    The authors review and discuss the biomechanics of forward power skating with respect to starting, acceleration, and striding. Comparisons are made to the biomechanics of walking. The dynamics of foot function within the skate boot are also discussed.

  3. Lower Extremity Energy Absorption and Biomechanics During Landing, Part II: Frontal-Plane Energy Analyses and Interplanar Relationships

    PubMed Central

    Norcross, Marc F.; Lewek, Michael D.; Padua, Darin A.; Shultz, Sandra J.; Weinhold, Paul S.; Blackburn, J. Troy

    2013-01-01

    Context: Greater sagittal-plane energy absorption (EA) during the initial impact phase (INI) of landing is consistent with sagittal-plane biomechanics that likely increase anterior cruciate ligament (ACL) loading, but it does not appear to influence frontal-plane biomechanics. We do not know whether frontal-plane INI EA is related to high-risk frontal-plane biomechanics. Objective: To compare biomechanics among INI EA groups, determine if women are represented more in the high group, and evaluate interplanar INI EA relationships. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Participants included 82 (41 men, 41 women; age = 21.0 ± 2.4 years, height = 1.74 ± 0.10 m, mass = 70.3 ± 16.1 kg) healthy, physically active volunteers. Intervention(s): We assessed landing biomechanics with an electromagnetic motion-capture system and force plate. Main Outcome Measure(s): We calculated frontal- and sagittal-plane total, hip, knee, and ankle INI EA. Total frontal-plane INI EA was used to create high, moderate, and low tertiles. Frontal-plane knee and hip kinematics, peak vertical and posterior ground reaction forces, and peak internal knee-varus moment (pKVM) were identified and compared across groups using 1-way analyses of variance. We used a χ2 analysis to evaluate male and female allocation to INI EA groups. We used simple, bivariate Pearson product moment correlations to assess interplanar INI EA relationships. Results: The high–INI EA group exhibited greater knee valgus at ground contact, hip adduction at pKVM, and peak hip adduction than the low–INI EA group (P < .05) and greater peak knee valgus, pKVM, and knee valgus at pKVM than the moderate– (P < .05) and low– (P < .05) INI EA groups. Women were more likely than men to be in the high–INI EA group (χ2 = 4.909, P = .03). Sagittal-plane knee and frontal-plane hip INI EA (r = 0.301, P = .006) and sagittal-plane and frontal-plane ankle INI EA were

  4. Lower- extremity biomechanics and maintenance of vertical-jump height during prolonged intermittent exercise.

    PubMed

    Schmitz, Randy J; Cone, John C; Copple, Timothy J; Henson, Robert A; Shultz, Sandra J

    2014-11-01

    Potential biomechanical compensations allowing for maintenance of maximal explosive performance during prolonged intermittent exercise, with respect to the corresponding rise in injury rates during the later stages of exercise or competition, are relatively unknown. To identify lower-extremity countermovement-jump (CMJ) biomechanical factors using a principal-components approach and then examine how these factors changed during a 90-min intermittent-exercise protocol (IEP) while maintaining maximal jump height. Mixed-model design. Laboratory. Fifty-nine intermittent-sport athletes (30 male, 29 female) participated in experimental and control conditions. Before and after a dynamic warm-up and every 15 min during the 1st and 2nd halves of an individually prescribed 90-min IEP, participants were assessed on rating of perceived exertion, sprint/cut speed, and 3-dimensional CMJ biomechanics (experimental). On a separate day, the same measures were obtained every 15 min during 90 min of quiet rest (control). Univariate piecewise growth models analyzed progressive changes in CMJ performance and biomechanical factors extracted from a principal-components analysis of the individual biomechanical dependent variables. While CMJ height was maintained during the 1st and 2nd halves, the body descended less and knee kinetic and energetic magnitudes decreased as the IEP progressed. The results indicate that vertical-jump performance is maintained along with progressive biomechanical changes commonly associated with decreased performance. A better understanding of lower-extremity biomechanics during explosive actions in response to IEP allows us to further develop and individualize performance training programs.

  5. Effect of Fasting on Corneal Biomechanical and Structural Parameters.

    PubMed

    Sarici, Ahmet M; Yuksel Elgin, Cansu; Dikkaya, Funda

    2016-07-01

    To evaluate the effects of hunger and thirst on corneal biomechanical and structural parameters during Ramadan fasting. Corneal biomechanical properties and intraocular pressures of 29 eyes of 29 healthy subjects were evaluated by Reichert ocular response analyzer; and structural and anatomical properties of cornea and anterior eye chamber of same eyes were scanned with Oculus Pentacam anterior segment analyzer. Each eye has been evaluated at 8 am and 4 pm both during and 1 month after Ramadan. Changes of subjects' weight were calculated and their relationship with corneal biomechanical and structural parameters was assessed. Intraday changes in horizontal corneal astigmatism (p = 0.02), anterior chamber volume (p = 0.01), intraocular pressure associated with the Goldmann IOPg (p = 0.02) and corneal resistance factor (CRF) (p = 0.04) were significantly different when measured during the fasting period in Ramadan and 1 month thereafter. Moreover, when we compared 8 am measurements taken during and after Ramadan, we observed significant differences for anterior chamber volume (p = 0.04) and anterior chamber angle values (p = 0.03). Similarly, for 4 pm measurements, there were significant differences for IOPg (p = 0.01) and CRF values (p = 0.00). Fasting lasting for more than 12 h during Ramadan creates an important window of opportunity to investigate the response of anterior chamber of eye to hunger and thirst. The current study contributes to the existing literature on the effects of dietary habits and water intake on corneal and anterior chamber properties.

  6. Pediatric short-distance household falls: biomechanics and associated injury severity.

    PubMed

    Thompson, Angela K; Bertocci, Gina; Rice, Wayne; Pierce, Mary C

    2011-01-01

    Short-distance household falls are a common occurrence in young children, but are also a common false history given by caretakers to conceal abusive trauma. The purpose of this study was to determine the severity of injuries that result from accidental short-distance household falls in children, and to investigate the association of fall environment and biomechanical measures with injury outcomes. Children aged 0-4 years who presented to the Emergency Department with a history of a short furniture fall were included in the study. Detailed case-based biomechanical assessments were performed using data collected through medical records, interviews, and fall scene investigations. Injuries were rated using the Abbreviated Injury Scale (AIS). Each case was reviewed by a child abuse expert; cases with a vague or inconsistent history and cases being actively investigated for child abuse were excluded. 79 subjects were enrolled in the study; 15 had no injuries, 45 had minor (AIS 1) injuries, 17 had moderate (AIS 2) injuries, and 2 had serious (AIS 3) injuries. No subjects had injuries classified as AIS 4 or higher, and there were no fatalities. Children with moderate or serious injuries resulting from a short-distance household fall tended to have fallen from greater heights, have greater impact velocities, and have a lower body mass index than those with minor or no injuries. Children aged 0-4 years involved in a short-distance household fall did not sustain severe or life-threatening injuries, and no children in this study had moderate or serious injuries to multiple body regions. Biomechanical measures were found to be associated with injury severity outcomes in short-distance household falls. Knowledge of relationships between biomechanical measures and injury outcomes can aid clinicians when assessing whether a child's injuries were the result of a short-distance fall or some other cause. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Biomechanical implications of walking with indigenous footwear

    PubMed Central

    Willems, Catherine; Stassijns, Gaetane; Cornelis, Wim; D'Août, Kristiaan

    2017-01-01

    Abstract Objectives This study investigates biomechanical implications of walking with indigenous “Kolhapuri” footwear compared to barefoot walking among a population of South Indians. Materials and methods Ten healthy adults from South India walked barefoot and indigenously shod at voluntary speed on an artificial substrate. The experiment was repeated outside, on a natural substrate. Data were collected from (1) a heel‐mounted 3D‐accelerometer recording peak impact at heel contact, (2) an ankle‐mounted 3D‐goniometer (plantar/dorsiflexion and inversion/eversion), and (3) sEMG electrodes at the m. tibialis anterior and the m. gastrocnemius medialis. Results Data show that the effect of indigenous footwear on the measured variables, compared to barefoot walking, is relatively small and consistent between substrates (even though subjects walked faster on the natural substrate). Walking barefoot, compared to shod walking yields higher impact accelerations, but the differences are small and only significant for the artificial substrate. The main rotations of the ankle joint are mostly similar between conditions. Only the shod condition shows a faster ankle rotation over the rapid eversion motion on the natural substrate. Maximal dorsiflexion in late stance differs between the footwear conditions on an artificial substrate, with the shod condition involving a less dorsiflexed ankle, and the plantar flexion at toe‐off is more extreme when shod. Overall the activity pattern of the external foot muscles is similar. Discussion The indigenous footwear studied (Kolhapuri) seems to alter foot biomechanics only in a subtle way. While offering some degree of protection, walking in this type of footwear resembles barefoot gait and this type of indigenous footwear might be considered “minimal”. PMID:28101944

  8. [RESEARCH PROGRESS OF BIOMECHANICS OF PROXIMAL ROW CARPAL INSTABILITY].

    PubMed

    Guo, Jinhai; Huang, Fuguo

    2015-01-01

    To review the research progress of the biomechanics of proximal row carpal instability (IPRC). The related literature concerning IPRC was extensively reviewed. The biomechanical mechanism of the surrounding soft tissue in maintaining the stability of the proximal row carpal (PRC) was analyzed, and the methods to repair or reconstruct the stability and function of the PRC were summarized from two aspects including basic biomechanics and clinical biomechanics. The muscles and ligaments of the PRC are critical to its stability. Most scholars have reached a consensus about biomechanical mechanism of the PRC, but there are still controversial conclusions on the biomechanics mechanism of the surrounding soft tissue to stability of distal radioulnar joint when the triangular fibrocartilage complex are damaged and the biomechanics mechanism of the scapholunate ligament. At present, there is no unified standard about the methods to repair or reconstruct the stability and function of the PRC. So, it is difficult for clinical practice. Some strides have been made in the basic biomechanical study on muscle and ligament and clinical biomechanical study on the methods to repair or reconstruct the stability and function of PRC, but it will be needed to further study the morphology of carpal articular surface and the adjacent articular surface, the pressure of distal carpals to proximal carpal and so on.

  9. An on-ice measurement approach to analyse the biomechanics of ice hockey skating.

    PubMed

    Buckeridge, Erica; LeVangie, Marc C; Stetter, Bernd; Nigg, Sandro R; Nigg, Benno M

    2015-01-01

    Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High) and nine low caliber (Low) hockey players performed 30 m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65) to excellent (r>0.95) scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05). High caliber exhibited greater hip range of motion and forefoot force application (p<0.05). The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice.

  10. DATA QUALITY OBJECTIVES AND MEASUREMENT QUALITY OBJECTIVES FOR RESEARCH PROJECTS

    EPA Science Inventory

    The paper provides assistance with systematic planning using measurement quality objectives to those working on research projects. These performance criteria are more familiar to researchers than data quality objectives because they are more closely associated with the measuremen...

  11. Teaching undergraduate biomechanics with Just-in-Time Teaching.

    PubMed

    Riskowski, Jody L

    2015-06-01

    Biomechanics education is a vital component of kinesiology, sports medicine, and physical education, as well as for many biomedical engineering and bioengineering undergraduate programmes. Little research exists regarding effective teaching strategies for biomechanics. However, prior work suggests that student learning in undergraduate physics courses has been aided by using the Just-in-Time Teaching (JiTT). As physics understanding plays a role in biomechanics understanding, the purpose of study was to evaluate the use of a JiTT framework in an undergraduate biomechanics course. This two-year action-based research study evaluated three JiTT frameworks: (1) no JiTT; (2) mathematics-based JiTT; and (3) concept-based JiTT. A pre- and post-course assessment of student learning used the biomechanics concept inventory and a biomechanics concept map. A general linear model assessed differences between the course assessments by JiTT framework in order to evaluate learning and teaching effectiveness. The results indicated significantly higher learning gains and better conceptual understanding in a concept-based JiTT course, relative to a mathematics-based JiTT or no JiTT course structure. These results suggest that a course structure involving concept-based questions using a JiTT strategy may be an effective method for engaging undergraduate students and promoting learning in biomechanics courses.

  12. Lower Extremity Energy Absorption and Biomechanics During Landing, Part I: Sagittal-Plane Energy Absorption Analyses

    PubMed Central

    Norcross, Marc F.; Lewek, Michael D.; Padua, Darin A.; Shultz, Sandra J.; Weinhold, Paul S.; Blackburn, J. Troy

    2013-01-01

    Context: Eccentric muscle actions of the lower extremity absorb kinetic energy during landing. Greater total sagittal-plane energy absorption (EA) during the initial impact phase (INI) of landing has been associated with landing biomechanics considered high risk for anterior cruciate ligament (ACL) injury. We do not know whether groups with different INI EA magnitudes exhibit meaningful differences in ACL-related landing biomechanics and whether INI EA might be useful to identify ACL injury-risk potential. Objective: To compare biomechanical factors associated with noncontact ACL injury among sagittal-plane INI EA groups and to determine whether an association exists between sex and sagittal-plane INI EA group assignment to evaluate the face validity of using sagittal-plane INI EA to identify ACL injury risk. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: A total of 82 (41 men, 41 women; age = 21.0 ± 2.4 years, height = 1.74 ± 0.10 m, mass = 70.3 ± 16.1 kg) healthy, physically active individuals volunteered. Intervention(s): We assessed landing biomechanics using an electromagnetic motion-capture system and force plate during a double-legged jump-landing task. Main Outcome Measure(s): Total INI EA was used to group participants into high, moderate, and low tertiles. Sagittal- and frontal-plane knee kinematics; peak vertical and posterior ground reaction forces (GRFs); anterior tibial shear force; and internal hip extension, knee extension, and knee varus moments were identified and compared across groups using 1-way analyses of variance. We used a χ2 analysis to compare male and female representation in the high and low groups. Results: The high group exhibited greater knee-extension moment and posterior GRFs than both the moderate (P < .05) and low (P < .05) groups and greater anterior tibial shear force than the low group (P < .05). No other group differences were noted. Women were not represented more than

  13. Cycling biomechanics: a literature review.

    PubMed

    Wozniak Timmer, C A

    1991-01-01

    Submitted in partial fulfillment for a Master of Science degree at the University of Pittsburgh, School of Health Related Professions, Pittsburgh, PA 1.5213 This review of current literature on cycling biomechanics emphasizes lower extremity muscle actions and joint excursions, seat height, pedal position, pedaling rate, force application, and pedaling symmetry. Guidelines are discussed for optimal seat height, pedal position, and pedaling rate. Force application in the power and recovery phases of cycling and the relationship of force application to pedaling symmetry are discussed. The need for a biomechanical approach to cycling exists since a great deal of the literature is primarily physiologic in nature. The purpose of this review is to make cyclists and their advisors aware of the biomechanics of cycling and guidelines to follow. This approach is also important because cycling is a very common form of exercise prescribed by physical therapists for clinic or home programs. Biomechanical aspects of cycling should be considered by cyclists at any level of participation and by physical therapists in order for goal-oriented, efficient cycling to occur. J Orthop Sports Phys Ther 1991;14(3):106-113.

  14. Biomechanical variables and perception of comfort in running shoes with different cushioning technologies.

    PubMed

    Dinato, Roberto C; Ribeiro, Ana P; Butugan, Marco K; Pereira, Ivye L R; Onodera, Andrea N; Sacco, Isabel C N

    2015-01-01

    To investigate the relationships between the perception of comfort and biomechanical parameters (plantar pressure and ground reaction force) during running with four different types of cushioning technology in running shoes. Randomized repeated measures. Twenty-two men, recreational runners (18-45 years) ran 12km/h with running shoes with four different cushioning systems. Outcome measures included nine items related to perception of comfort and 12 biomechanical measures related to the ground reaction forces and plantar pressures. Repeated measure ANOVAs, Pearson correlation coefficients, and step-wise multiple regression analyses were employed (p≤0.05). No significant correlations were found between the perception of comfort and the biomechanical parameters for the four types of investigated shoes. Regression analysis revealed that 56% of the perceived general comfort can be explained by the variables push-off rate and pressure integral over the forefoot (p=0.015) and that 33% of the perception of comfort over the forefoot can be explained by second peak force and push-off rate (p=0.016). The results did not demonstrate significant relationships between the perception of comfort and the biomechanical parameters for the three types of shoes investigated (Gel, Air, and ethylene-vinyl acetate). Only the shoe with Adiprene+ technology had its general comfort and cushioning perception predicted by the loads over the forefoot. Thus, in general, one cannot predict the perception of comfort of a running shoe through impact and plantar pressure received. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. A novel biomechanical model assessing continuous orthodontic archwire activation

    PubMed Central

    Canales, Christopher; Larson, Matthew; Grauer, Dan; Sheats, Rose; Stevens, Clarke; Ko, Ching-Chang

    2013-01-01

    Objective The biomechanics of a continuous archwire inserted into multiple orthodontic brackets is poorly understood. The purpose of this research was to apply the birth-death technique to simulate insertion of an orthodontic wire and consequent transfer of forces to the dentition in an anatomically accurate model. Methods A digital model containing the maxillary dentition, periodontal ligament (PDL), and surrounding bone was constructed from human computerized tomography data. Virtual brackets were placed on four teeth (central and lateral incisors, canine and first premolar), and a steel archwire (0.019″ × 0.025″) with a 0.5 mm step bend to intrude the lateral incisor was virtually inserted into the bracket slots. Forces applied to the dentition and surrounding structures were simulated utilizing the birth-death technique. Results The goal of simulating a complete bracket-wire system on accurate anatomy including multiple teeth was achieved. Orthodontic force delivered by the wire-bracket interaction was: central incisor 19.1 N, lateral incisor 21.9 N, and canine 19.9 N. Loading the model with equivalent point forces showed a different stress distribution in the PDL. Conclusions The birth-death technique proved to be a useful biomechanical simulation method for placement of a continuous archwire in orthodontic brackets. The ability to view the stress distribution throughout proper anatomy and appliances advances understanding of orthodontic biomechanics. PMID:23374936

  16. Biomechanical versus Inertial Information: Stable Individual Differences in Perception of Self-Rotation

    ERIC Educational Resources Information Center

    Bruggeman, Hugo; Piuneu, Vadzim S.; Rieser, John J.; Pick, Herbert L., Jr.

    2009-01-01

    When turning without vision or audition, people tend to perceive their locomotion as a change in heading relative to objects in the remembered surroundings. Such perception of self-rotation depends on sensitivity to information for movement from biomechanical activity of the locomotor system or from inertial activation of the vestibular and…

  17. In Vivo Engineering of the Vocal Fold ECM with Injectable HA Hydrogels -- Late Effects on Tissue Repair and Biomechanics in a Rabbit Model

    PubMed Central

    Klemuk, Sarah A.; Chen, Xia; Quinchia Johnson, Beatriz H.

    2009-01-01

    Objectives To determine if the utilization of injectable chemically-modified hyaluronan (HA) derivative at the time of intentional vocal fold resection may facilitate wound repair and preserve the unique viscoelastic properties of the extracellular matrix and lamina propria 6 months after treatment. Study Design Prospective, controlled animal study. Methods Twelve rabbit vocal folds were biopsied bilaterally, and the left side of vocal fold was treated with Extracel, an injectable, chemically-modified HA derivative, and the right side of vocal fold was injected with saline as control at the time of resection. Animals were sacrificed six months after biopsy and injection. Outcomes measured include transcription levels for procollagen, fibronectin, fibromodulin, TGF-β1, hyaluronan synthase and hyaluronidase and tissue biomechanics -- viscosity and elasticity. Results Extracel treated vocal folds were found to have significantly less fibrosis than saline treated controls. Extracel treated vocal folds had significantly improved biomechanical properties of elasticity and viscosity. Significantly decreased levels of fibronectin, fibromodulin, TGF-β1, procollagen I and hyaluronan synthase were measured. Conclusions Prophylactic in vivo manipulation of the extracellular matrix with an injectable HA hydrogel appears to induce vocal fold tissue regeneration to yield improved tissue composition and biomechanical properties at 6 months. PMID:20456912

  18. Biomechanical Changes After LASIK Flap Creation Combined With Rapid Cross-Linking Measured With Brillouin Microscopy.

    PubMed

    Randleman, J Bradley; Su, Johnny P; Scarcelli, Giuliano

    2017-06-01

    To evaluate the biomechanical changes occurring after LASIK flap creation and rapid corneal cross-linking (CXL) measured with Brillouin light microscopy. Porcine eyes (n = 11) were evaluated by Brillouin light microscopy sequentially in the following order: virgin state, after LASIK flap creation, and after rapid CXL. Each eye served as its own control. Depth profile of the Brillouin frequency shift was computed to reveal the depth-dependent changes in corneal stiffness. There was a statistically significant reduction of Brillouin shift (reduced corneal stiffness) after LASIK flap creation compared to virgin corneas across total corneal thickness (-0.035 GHz, P = .0195) and within the anterior stromal region (-0.104 GHz, P = .0039). Changes in the central (-0.029 GHz, P = .0391) and posterior (-0.005 GHz, P = .99) stromal regions were not significant. There was a small increase in Brillouin shift after rapid cross-linking that was not statistically or clinically significant across total corneal thickness (0.006 GHz, P = .4688 for any specific stromal region; 0.002 to 0.009 GHz, P > .46 for all). LASIK flap creation significantly reduced Brillouin shift in the anterior third of the stroma in porcine eyes. Rapid corneal cross-linking had no significant effect on Brillouin shift after LASIK flap creation in porcine eyes. With further validation, non-contact, non-perturbative Brillouin microscopy could become a useful monitoring tool to evaluate the biomechanical impact of corneal refractive procedures and corneal cross-linking protocols. [J Refract Surg. 2017;33(6):408-414.]. Copyright 2017, SLACK Incorporated.

  19. Is objectively measured sitting at work associated with low-back pain? A cross sectional study in the DPhacto cohort.

    PubMed

    Korshøj, Mette; Hallman, David M; Mathiassen, Svend Erik; Aadahl, Mette; Holtermann, Andreas; Jørgensen, Marie Birk

    2018-01-01

    Objectives Low-back pain (LBP) is a substantial health challenge due to the risk for long-term sickness absence and early retirement. Several biomechanical exposures at work, including sitting, have been suggested to increase the risk for LBP. The objectives of this study were to determine (i) the extent to which temporal patterns and total amount of objectively measured sitting is associated with LBP intensity and (ii) whether selected modifiers influence these associations. Methods This cross sectional study uses baseline data from the Danish PHysical ACTivity cohort with Objective measurements (DPhacto) of physical activities in the cleaning, transport and manufacturing sectors. Peak intensity of LBP was collected by questionnaire on a 0-10 scale and sitting was expressed in terms of total duration and temporal pattern, ie, time spent in brief bursts (≤5 minutes), moderate periods (>5-≤20 minutes), and prolonged periods of sitting (>20 minutes); both during work and whole day (waking hours only). Associations were determined using linear regression in models accounting for moderation and confounding. Factors evaluated as moderators or confounders were assessed by questionnaire. Results The population consisted of 704 participants. No significant associations were found between total duration or temporal patterns of sitting and LBP intensity, neither during work nor for the whole day. Body mass index (BMI) significantly moderated the association between sitting and LBP; participants with a high and low BMI showing a negative and positive association, respectively. Conclusion Sitting was not independently associated with peak LBP intensity, suggesting other exposures are more powerful risk factors for LBP.

  20. Biomechanical evaluation of a biomimetic spinal construct.

    PubMed

    Wang, Tian; Ball, Jonathon R; Pelletier, Mattew H; Walsh, William R

    2014-12-01

    Laboratory spinal biomechanical tests using human cadaveric or animal spines have limitations in terms of disease transmission, high sample variability, decay and fatigue during extended testing protocols. Therefore, a synthetic biomimetic spine model may be an acceptable substitute. The goal of current study is to evaluate the properties of a synthetic biomimetic spine model; also to assess the mechanical performance of lateral plating following lateral interbody fusion. Three L3/4 synthetic spinal motion segments were examined using a validated pure moment testing system. Moments (±7.5 Nm) were applied in flexion-extension (FE), lateral bending (LB) and axial rotation (AR) at 1Hz for total 10000 cycles in MTS Bionix. An additional test was performed 12 hours after 10000 cycles. A ±10 Nm cycle was also performed to allow provide comparison to the literature. For implantation evaluation, each model was tested in the 4 following conditions: 1) intact, 2) lateral cage alone, 3) lateral cage and plate 4) anterior cage and plate. Results were analysed using ANOVA with post-hoc Tukey's HSD test. Range of motion (ROM) exhibited logarithmic growth with cycle number (increases of 16%, 37.5% and 24.3% in AR, FE and LB respectively). No signification difference (p > 0.1) was detected between 4 cycles, 10000 cycles and 12 hour rest stages. All measured parameters were comparable to that of reported cadaveric values. The ROM for a lateral cage and plate construct was not significantly different to the anterior lumbar interbody construct for FE (p = 1.00), LB (p = 0.995) and AR (p = 0.837). Based on anatomical and biomechanical similarities, the synthetic spine tested here provides a reasonable model to represent the human lumbar spine. Repeated testing did not dramatically alter biomechanics which may allow non-destructive testing between many different procedures and devices without the worry of carry over effects. Small intra-specimen variability

  1. Biomechanical Properties of the Skin in Patients with Breast Cancer-Related Lymphedema Compared to Healthy Individuals.

    PubMed

    Killaars, R C; Penha, T R Lopez; Heuts, E M; van der Hulst, R R J W; Piatkowski, A A

    2015-09-01

    Biomechanical skin changes in breast cancer-related lymphedema (BRCL) have barely been described and objectively tested. This study aims to compare the skin of upper limb lymphedema with skin of the healthy contralateral arm, in order to demonstrate changes of elasticity, viscoelasticity, and level of hydration of the skin in BCRL. The secondary aim is to investigate the correlation between biomechanical skin changes and measurements that are currently used in clinical practice, such as volume measurement and lymph-ICF score. Eighteen patients with BCRL and 18 healthy individuals were included in the study. A Cutometer® was used for measurements for skin elasticity and viscoelasticity on both arms of each subject. A Corneometer® was used for measurements of skin hydration. Measurements of both test groups were compared. In BCRL patients, there was a significant difference (p = < 0.028) between the elasticity of the skin of the lymphedema arm compared to the healthy contralateral arm. There were no significant differences for level of skin hydration or viscoelasticity in lymphedema patients between the measurements on the skin of the lymphedematous and healthy arm. In healthy individuals, there were no significant differences for all measurements between skin of both arms. Spearman's correlation was significant (p = < 0.01) for difference in volume and difference in elasticity in BCRL patients. This study shows an impaired elasticity for the skin of the lower arm in patients with lymphedema compared to the contralateral healthy arm. Promising evidence is suggested for the use of the Cutometer device in the diagnostic evaluation of BCRL.

  2. Measuring what matters: does 'objectivity' mean good science?

    PubMed

    Kayes, Nicola M; McPherson, Kathryn M

    2010-01-01

    While the limitations of self-report measures are clearly acknowledged, less apparent is attention to the potential limitations of their 'objective' counterparts leading to the assumption that objectivity results in more robust and scientifically valid measurement tools. This article aims to: (1) test this assumption; (2) consider the implications of advocating for a measure on the basis of its objectivity; (3) propose an alternative approach to measure selection. A critical evaluation of one 'objective' measure highlights a number of potential limitations suggesting that the apparent willingness to adopt 'objective' measures with little questioning may be misguided. The possible implications of this are discussed and include a risk to the advancement of, and capacity for, knowledge in rehabilitation; or worse, of making clinical decisions based on erroneous conclusions. Characterising a measure on the basis of objectivity (or not) assumes an overly simplistic dichotomy that is unhelpful and perhaps misleading. We argue that assessing whether a measure is fit for purpose and makes mathematical sense is the key consideration. Indeed, in some cases, using both an 'objective' measure and a subjective rating scale may be appropriate and the only way of truly capturing the phenomenon of interest.

  3. Influence of heel height and shoe insert on comfort perception and biomechanical performance of young female adults during walking.

    PubMed

    Hong, Wei-Hsien; Lee, Yung-Hui; Chen, Hsieh-Ching; Pei, Yu-Cheng; Wu, Ching-Yi

    2005-12-01

    The possible negative effects of high-heeled shoes on subjective comfort perception and objective biomechanical assessment have been noted. Although shoe inserts have been widely applied in footwear to increase comfort and to reduce the frequency of movement-related injury, no study has attempted to identify insert effectiveness in high heels. The purpose of this study was to determine the effects of heel height and shoe inserts on comfort and biomechanics as represented by plantar pressure and ground reaction force (GRF). Twenty young female adults performed the test conditions formed by the cross-matching of shoe inserts (shoe without insert and shoe with total contact insert [TCI]) and heel height (a flat, a low heel [3.8 cm] and a high heel [7.6 cm]). Two-way analyses of variance for repeated measures design were used to test condition effects on comfort rating, plantar pressure, and GRF during gait. To determine the biomechanical variables that can predict comfort, a multiple linear regression with stepwise method was done. The results showed that discomfort increased with heel height. In high heels, the plantar pressure in the heel and midfoot shifted to the medial forefoot, and the vertical and anteroposterior GRF increased. Use of the TCI reduced the peak pressure in the medial forefoot. Interestingly, the effectiveness of the TCI was greater in the higher heels than in the lower heels and in flat heels. The peak pressure in the medial forefoot, impact force, and the first peak vertical GRF could explain 75.6% of the variance of comfort in high-heeled gait. These findings suggest that higher heels result in decreased comfort, which can be reflected by both the subjective rating scale and biomechanical variables. Use of a TCI altered the biomechanics and therefore improved the comfort in high-heeled shoes.

  4. Gait biomechanics in the era of data science.

    PubMed

    Ferber, Reed; Osis, Sean T; Hicks, Jennifer L; Delp, Scott L

    2016-12-08

    Data science has transformed fields such as computer vision and economics. The ability of modern data science methods to extract insights from large, complex, heterogeneous, and noisy datasets is beginning to provide a powerful complement to the traditional approaches of experimental motion capture and biomechanical modeling. The purpose of this article is to provide a perspective on how data science methods can be incorporated into our field to advance our understanding of gait biomechanics and improve treatment planning procedures. We provide examples of how data science approaches have been applied to biomechanical data. We then discuss the challenges that remain for effectively using data science approaches in clinical gait analysis and gait biomechanics research, including the need for new tools, better infrastructure and incentives for sharing data, and education across the disciplines of biomechanics and data science. By addressing these challenges, we can revolutionize treatment planning and biomechanics research by capitalizing on the wealth of knowledge gained by gait researchers over the past decades and the vast, but often siloed, data that are collected in clinical and research laboratories around the world. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. The biomechanics of seed germination.

    PubMed

    Steinbrecher, Tina; Leubner-Metzger, Gerhard

    2017-02-01

    From a biomechanical perspective, the completion of seed (and fruit) germination depends on the balance of two opposing forces: the growth potential of the embryonic axis (radicle-hypocotyl growth zone) and the restraint of the seed-covering layers (endosperm, testa, and pericarp). The diverse seed tissues are composite materials which differ in their dynamic properties based on their distinct cell wall composition and water uptake capacities. The biomechanics of embryo cell growth during seed germination depend on irreversible cell wall loosening followed by water uptake due to the decreasing turgor, and this leads to embryo elongation and eventually radicle emergence. Endosperm weakening as a prerequisite for radicle emergence is a widespread phenomenon among angiosperms. Research into the biochemistry and biomechanics of endosperm weakening has demonstrated that the reduction in puncture force of a seed's micropylar endosperm is environmentally and hormonally regulated and involves tissue-specific expression of cell wall remodelling proteins such as expansins, diverse hydrolases, and the production of directly acting apoplastic reactive oxygen. The endosperm-weakening biomechanics and its underlying cell wall biochemistry differ between the micropylar (ME) and chalazal (CE) endosperm domains. In the ME, they involve cell wall loosening, cell separation, and programmed cell death to provide decreased and localized ME tissue resistance, autolysis, and finally the formation of an ME hole required for radicle emergence. Future work will further unravel the molecular mechanisms, environmental regulation, and evolution of the diverse biomechanical cell wall changes underpinning the control of germination by endosperm weakening. © The Author 2016. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. Biomechanics of Cardiac Function

    PubMed Central

    Voorhees, Andrew P.; Han, Hai-Chao

    2015-01-01

    The heart pumps blood to maintain circulation and ensure the delivery of oxygenated blood to all the organs of the body. Mechanics play a critical role in governing and regulating heart function under both normal and pathological conditions. Biological processes and mechanical stress are coupled together in regulating myocyte function and extracellular matrix structure thus controlling heart function. Here we offer a brief introduction to the biomechanics of left ventricular function and then summarize recent progress in the study of the effects of mechanical stress on ventricular wall remodeling and cardiac function as well as the effects of wall mechanical properties on cardiac function in normal and dysfunctional hearts. Various mechanical models to determine wall stress and cardiac function in normal and diseased hearts with both systolic and diastolic dysfunction are discussed. The results of these studies have enhanced our understanding of the biomechanical mechanism in the development and remodeling of normal and dysfunctional hearts. Biomechanics provide a tool to understand the mechanism of left ventricular remodeling in diastolic and systolic dysfunction and guidance in designing and developing new treatments. PMID:26426462

  7. Objectivity in psychosocial measurement: what, why, how.

    PubMed

    Fisher, W P

    2000-01-01

    This article raises and tries to answer questions concerning what objectivity in psychosocial measurement is, why it is important, and how it can be achieved. Following in the tradition of the Socratic art of maiuetics, objectivity is characterized by the separation of meaning from the geometric, metaphoric, or numeric figure carrying it, allowing an ideal and abstract entity to take on a life of its own. Examples of objective entities start from anything teachable and learnable, but for the purposes of measurement, the meter, gram, volt, and liter are paradigmatic because of their generalizability across observers, instruments, laboratories, samples, applications, etc. Objectivity is important because it is only through it that distinct conceptual entities are meaningfully distinguished. Seen from another angle, objectivity is important because it defines the conditions of the possibility of shared meaning and community. Full objectivity in psychosocial measurement can be achieved only by attending to both its methodological and its social aspects. The methodological aspect has recently achieved some notice in psychosocial measurement, especially in the form of Rasch's probabilistic conjoint models. Objectivity's social aspect has only recently been noticed by historians of science, and has not yet been systematically incorporated in any psychosocial science. An approach to achieving full objectivity in psychosocial measurement is adapted from the ASTM Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method (ASTM Committee E-11 on Statistical Methods, 1992).

  8. Applied Biomechanics in an Instructional Setting

    ERIC Educational Resources Information Center

    Hudson, Jackie L.

    2006-01-01

    Biomechanics is the science of how people move better, meaning more skillfully and more safely. This article places more emphasis on skill rather than safety, though there are many parallels between them. It shares a few features of the author's paradigm of applied biomechanics and discusses an integrated approach toward a middle school football…

  9. Effect of dermal thickness, tissue composition, and body site on skin biomechanical properties.

    PubMed

    Smalls, Lola K; Randall Wickett, R; Visscher, Marty O

    2006-02-01

    Quantitative measurement of skin biomechanical properties has been used effectively in the investigation of physiological changes in tissue structure and function and to determine treatment efficacy. As the methods are applied to new questions, tissue characteristics that may influence the resultant biomechanical properties are important considerations in the research design. For certain applications, variables such as dermal thickness and subdermal tissue composition, as well as age and/or solar exposure, may influence the skin biomechanics. We determined the influence of dermal thickness, tissue composition, and age on the skin biomechanical properties at the shoulder, thigh, and calf among 30 healthy females. We compared two devices, the Biomechanical Tissue Characterization System and the Cutometer SEM 575 Skin Elasticity Meter , to determine the effect of tissue sampling size. Dermal thickness was measured with 20 MHz ultrasound (Dermascan C) and tissue composition was inferred from anthropomorphic data. Skin thickness was significantly correlated with stiffness, energy absorption, and U(r)/U(f) for the shoulder. Body mass index (BMI) was significantly correlated with stiffness (negative correlation), energy absorption (positive), and skin thickness (negative) for the shoulder. Significant differences across body sites were observed. The calf was significantly different from the thigh and shoulders for all parameters (P<0.05, one-way anova). The calf had significantly lower laxity, laxity%, elastic deformation, energy absorption, elasticity, elasticity %, U(r), U(f), and U(r)/U(f) and significantly higher stiffness compared with the thighs and shoulders. sites. The thigh and shoulder sites were significantly different for all parameters except U(r)/U(f), elasticity %, laxity%, and stiffness. The dominant and non-dominant sides were significantly different. The dominant side (right for 90% of the subjects) had increased stiffness and decreased energy absorption

  10. Classification of deadlift biomechanics with wearable inertial measurement units.

    PubMed

    O'Reilly, Martin A; Whelan, Darragh F; Ward, Tomas E; Delahunt, Eamonn; Caulfield, Brian M

    2017-06-14

    The deadlift is a compound full-body exercise that is fundamental in resistance training, rehabilitation programs and powerlifting competitions. Accurate quantification of deadlift biomechanics is important to reduce the risk of injury and ensure training and rehabilitation goals are achieved. This study sought to develop and evaluate deadlift exercise technique classification systems utilising Inertial Measurement Units (IMUs), recording at 51.2Hz, worn on the lumbar spine, both thighs and both shanks. It also sought to compare classification quality when these IMUs are worn in combination and in isolation. Two datasets of IMU deadlift data were collected. Eighty participants first completed deadlifts with acceptable technique and 5 distinct, deliberately induced deviations from acceptable form. Fifty-five members of this group also completed a fatiguing protocol (3-Repition Maximum test) to enable the collection of natural deadlift deviations. For both datasets, universal and personalised random-forests classifiers were developed and evaluated. Personalised classifiers outperformed universal classifiers in accuracy, sensitivity and specificity in the binary classification of acceptable or aberrant technique and in the multi-label classification of specific deadlift deviations. Whilst recent research has favoured universal classifiers due to the reduced overhead in setting them up for new system users, this work demonstrates that such techniques may not be appropriate for classifying deadlift technique due to the poor accuracy achieved. However, personalised classifiers perform very well in assessing deadlift technique, even when using data derived from a single lumbar-worn IMU to detect specific naturally occurring technique mistakes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

    PubMed

    Tofts, P S; Silver, N C; Barker, G J; Gass, A

    2005-07-01

    There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.

  12. An On-Ice Measurement Approach to Analyse the Biomechanics of Ice Hockey Skating

    PubMed Central

    Buckeridge, Erica; LeVangie, Marc C.; Stetter, Bernd; Nigg, Sandro R.; Nigg, Benno M.

    2015-01-01

    Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High) and nine low caliber (Low) hockey players performed 30m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65) to excellent (r>0.95) scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05). High caliber exhibited greater hip range of motion and forefoot force application (p<0.05). The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice. PMID:25973775

  13. Utilization of ACL Injury Biomechanical and Neuromuscular Risk Profile Analysis to Determine the Effectiveness of Neuromuscular Training.

    PubMed

    Hewett, Timothy E; Ford, Kevin R; Xu, Yingying Y; Khoury, Jane; Myer, Gregory D

    2016-12-01

    The widespread use of anterior cruciate ligament (ACL) injury prevention interventions has not been effective in reducing the injury incidence among female athletes who participate in high-risk sports. The purpose of this study was to determine if biomechanical and neuromuscular factors that contribute to the knee abduction moment (KAM), a predictor of future ACL injuries, could be used to characterize athletes by a distinct factor. Specifically, we hypothesized that a priori selected biomechanical and neuromuscular factors would characterize participants into distinct at-risk profiles. Controlled laboratory study. A total of 624 female athletes who participated in jumping, cutting, and pivoting sports underwent testing before their competitive season. During testing, athletes performed drop-jump tasks from which biomechanical measures were captured. Using data from these tasks, latent profile analysis (LPA) was conducted to identify distinct profiles based on preintervention biomechanical and neuromuscular measures. As a validation, we examined whether the profile membership was a significant predictor of the KAM. LPA using 6 preintervention biomechanical measures selected a priori resulted in 3 distinct profiles, including a low (profile 1), moderate (profile 2), and high (profile 3) risk for ACL injuries. Athletes with profiles 2 and 3 had a significantly higher KAM compared with those with profile 1 (P < .05). This is the first study to use LPA of biomechanical landing data to create ACL injury risk profiles. Three distinct risk groups were identified based on differences in the peak KAM. These findings demonstrate the existence of discernable groups of athletes that may benefit from injury prevention interventions. ClinicalTrials.gov NCT identifier: NCT01034527. © 2016 The Author(s).

  14. Corneal biomechanical properties from air-puff corneal deformation imaging

    NASA Astrophysics Data System (ADS)

    Marcos, Susana; Kling, Sabine; Bekesi, Nandor; Dorronsoro, Carlos

    2014-02-01

    The combination of air-puff systems with real-time corneal imaging (i.e. Optical Coherence Tomography (OCT), or Scheimpflug) is a promising approach to assess the dynamic biomechanical properties of the corneal tissue in vivo. In this study we present an experimental system which, together with finite element modeling, allows measurements of corneal biomechanical properties from corneal deformation imaging, both ex vivo and in vivo. A spectral OCT instrument combined with an air puff from a non-contact tonometer in a non-collinear configuration was used to image the corneal deformation over full corneal cross-sections, as well as to obtain high speed measurements of the temporal deformation of the corneal apex. Quantitative analysis allows direct extraction of several deformation parameters, such as apex indentation across time, maximal indentation depth, temporal symmetry and peak distance at maximal deformation. The potential of the technique is demonstrated and compared to air-puff imaging with Scheimpflug. Measurements ex vivo were performed on 14 freshly enucleated porcine eyes and five human donor eyes. Measurements in vivo were performed on nine human eyes. Corneal deformation was studied as a function of Intraocular Pressure (IOP, 15-45 mmHg), dehydration, changes in corneal rigidity (produced by UV corneal cross-linking, CXL), and different boundary conditions (sclera, ocular muscles). Geometrical deformation parameters were used as input for inverse finite element simulation to retrieve the corneal dynamic elastic and viscoelastic parameters. Temporal and spatial deformation profiles were very sensitive to the IOP. CXL produced a significant reduction of the cornea indentation (1.41x), and a change in the temporal symmetry of the corneal deformation profile (1.65x), indicating a change in the viscoelastic properties with treatment. Combining air-puff with dynamic imaging and finite element modeling allows characterizing the corneal biomechanics in-vivo.

  15. Optic nerve head biomechanics in aging and disease.

    PubMed

    Downs, J Crawford

    2015-04-01

    This nontechnical review is focused upon educating the reader on optic nerve head biomechanics in both aging and disease along two main themes: what is known about how mechanical forces and the resulting deformations are distributed in the posterior pole and ONH (biomechanics) and what is known about how the living system responds to those deformations (mechanobiology). We focus on how ONH responds to IOP elevations as a structural system, insofar as the acute mechanical response of the lamina cribrosa is confounded with the responses of the peripapillary sclera, prelaminar neural tissues, and retrolaminar optic nerve. We discuss the biomechanical basis for IOP-driven changes in connective tissues, blood flow, and cellular responses. We use glaucoma as the primary framework to present the important aspects of ONH biomechanics in aging and disease, as ONH biomechanics, aging, and the posterior pole extracellular matrix (ECM) are thought to be centrally involved in glaucoma susceptibility, onset and progression. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Optic Nerve Head Biomechanics in Aging and Disease

    PubMed Central

    Downs, J. Crawford

    2015-01-01

    This nontechnical review is focused upon educating the reader on optic nerve head biomechanics in both aging and disease along two main themes: what is known about how mechanical forces and the resulting deformations are distributed in the posterior pole and ONH (biomechanics) and what is known about how the living system responds to those deformations (mechanobiology). We focus on how ONH responds to IOP elevations as a structural system, insofar as the acute mechanical response of the lamina cribrosa is confounded with the responses of the peripapillary sclera, prelaminar neural tissues, and retrolaminar optic nerve. We discuss the biomechanical basis for IOP-driven changes in connective tissues, blood flow, and cellular responses. We use glaucoma as the primary framework to present the important aspects of ONH biomechanics in aging and disease, as ONH biomechanics, aging, and the posterior pole extracellular matrix (ECM) are thought to be centrally involved in glaucoma susceptibility, onset and progression. PMID:25819451

  17. Measuring tactile cues at the fingerpad for object compliances harder and softer than the skin

    PubMed Central

    Hauser, Steven C.; Gerling, Gregory J.

    2016-01-01

    Distinguishing an object’s compliance, into percepts of “softness” and “hardness,” is crucial to our ability to grasp and manipulate it. Biomechanical cues at the skin’s surface such as contact area and force rate have been thought to help encode compliance. However, no one has directly measured contact area with compliant materials, and few studies have considered compliances softer than the fingerpad. Herein, we developed a novel method to precisely measure the area in contact between compliant stimuli and the fingerpad, at given levels of force and displacement. To determine the method’s robustness, we conducted psychophysical and biomechanical experiments with human subjects. The results indicate that cues including contact area at stimulus peak force of 3 Newtons, force rate over stimulus movement and at peak force, displacement and/or time to reach peak force may help in discriminating compliances while the directional spread of contact area is less important. Between softer and harder compliances, some cues were slightly more evident, though not yet definitively. Based upon the method’s utility, the next step is to conduct broader experiments to distill the mixture of cues that encode compliance. The importance of such work lies in building haptic displays, for example, to render virtual tissues. PMID:27331072

  18. The physiological and biomechanical effects of forwards and reverse sports wheelchair propulsion

    PubMed Central

    Mason, Barry S.; Lenton, John P.; Goosey-Tolfrey, Victoria L.

    2015-01-01

    Objective To explore the physiological and biomechanical differences between forwards (FOR) and reverse (REV) sports wheelchair propulsion. Design Fourteen able-bodied males with previous wheelchair propulsion experience pushed a sports wheelchair on a single-roller ergometer in a FOR and REV direction at three sub-maximal speeds (4, 6, and 8 km/hour). Each trial lasted 3 minutes, and during the final minute physiological and biomechanical measures was collected. Results The physiological results revealed that oxygen uptake (1.51 ± 0.29 vs. 1.38 ± 0.26 L/minute, P = 0.005) and heart rate (121 ± 19 vs. 109 ± 14 beats/minute, P < 0.0005) were significantly greater during REV than FOR only during the 8 km/hour trials. From a biomechanical perspective, push frequencies were similar between FOR and REV across all speeds (P > 0.05). However, greater mean resultant forces were applied during FOR (P < 0.0005) at 4 km/hour (66.7 ± 19.5 vs. 49.2 ± 10.3 N), 6 km/hour (90.7 ± 21.9 vs. 65.3 ± 18.6 N), and 8 km/hour (102.5 ± 17.6 vs. 68.7 ± 13.5 N) compared to REV. Alternatively, push times and push angles were significantly lower (P ≤ 0.001) during FOR at each speed. Conclusions The current study demonstrated that at higher speeds physiological demand becomes elevated during REV. This was likely to be associated with an inability to apply sufficient force to the wheels, thus requiring kinematic adaptations in order to maintain constant speeds in REV. PMID:24593797

  19. Evaluation of the biomechanics of atherosclerosis by acoustic microscopy

    NASA Astrophysics Data System (ADS)

    Saijo, Yoshifumi; Nitta, Shin-ichi; Schiott Jorgensen, Claus; Falk, Erling

    2001-07-01

    Acoustic microscopy provides not only the morphology, but also the biomechanical properties of the biological soft tissues. The biomechanics of atherosclerosis is important because the pathophysiology of atherosclerosis is closely related with mechanical properties and mechanical stress. Rupture of the fibrous cap of atheromatous plaque is the initial event in acute coronary syndrome such as acute myocardial infarction or unstable angina. In addition to extrinsic physical stresses to the plaque, the intrinsic biomechanical property of the plaque is important for assessing the mechanism of the rupture. Two sets of SAMs operating in 100 to 200 MHz and in 800 MHz to 1.3 GHz were equipped to measure the acoustic properties of atherosclerosis of human or mouse arteries. The values of attenuation and sound speed in the tissue components of atherosclerosis were measured by analyzing the frequency dependent characteristics of the amplitude and phase signals. Both values were highest in calcification and lowest in lipid pool. Although attenuation and sound speed were relatively high in intimal fibrosis, the inhomogeneity of acoustic parameters was found within the fibrous cap. Polarized microscopy for the collagen stained with Picrosirius red showed that the attenuation of ultrasound was significantly higher in type I collagen with orange polarized color compared to type III collagen with green color. SAM has shown the possibility to detect the plaque vulnerability and it might improve our understanding of the sudden rupture from micro-mechanical point of view.

  20. Absorbable scaphoid screw development: a comparative study on biomechanics

    PubMed Central

    Wang, Yi; Song, Muguo; Xu, Yongqing; He, Xiaoqing; Zhu, YueLiang

    2016-01-01

    Background The scaphoid is critical for maintaining the stability and movement of the wrist joints. This study aimed to develop a new internal fixator absorbable scaphoid screw (ASS) for fixation of the scaphoid waist after fracture and to test the biomechanical characteristics of ASS. Materials and methods An ASS was prepared using polylactic acids and designed based on scaphoid measurements and anatomic features. Twenty fractured scaphoid waist specimens were randomly divided into experimental and control groups (n=10/group). Reduction and internal fixation of the scaphoid were achieved with either Kirschner wires (K-wires) or ASS. A moving target simulator was used to test palmar flexion and dorsal extension, with the range of testing (waist movement) set from 5° of palmar flexion to 25° of dorsal extension. Flexion and extension were repeated 2,000 times for each specimen. Fracture gap displacements were measured with a computerized tomography scanning. Scaphoid tensile and bending strengths were measured by using a hydraulic pressure biomechanical system. Results Prior to biomechanical fatigue testing, fracture gap displacements were 0.16±0.02 mm and 0.22±0.02 mm in the ASS and K-wire groups, respectively. After fatigue testing, fracture gap displacements in the ASS and the K-wire groups were 0.21±0.03 mm and 1.52±0.07 mm, respectively. The tensile strengths for the ASS and K-wire groups were 0.95±0.02 MPa and 0.63±0.02 MPa, respectively. Conclusion Fixation using an ASS provided sufficient mechanical support for the scaphoid after fracture. PMID:27217756

  1. Correlating Corneal Biomechanics and Ocular Biometric Properties with Lamina Cribrosa Measurements in Healthy Subjects.

    PubMed

    Pérez Bartolomé, Francisco; Martínez de la Casa, Jose María; Camacho Bosca, Irene; Sáenz-Francés, Federico; Aguilar Munoa, Soledad; Martín Juan, Alberto; Garcia-Feijoo, Julian

    2018-01-01

    To examine interrelations between corneal biomechanics, ocular biometric variables and optic disc size (ODS), lamina cribosa depth (LCD) or thickness (LCT) in a healthy population. In a cross-sectional case-control study, the following measurements were made in 81 eyes of 81 participants: axial length, anterior chamber depth, lens thickness, and central corneal thickness using the optical biometer Lenstar LS900; and corneal hysteresis (CH), corneal resistance factor (CRF), Goldman-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) using the Ocular Response Analyzer. Serial horizontal enhanced depth imaging optical coherence tomography (EDI OCT) B-scans of the optic nerve head were obtained in each participant. Mean ODS, mean LCD, and mean LCT were measured in 11 equally spaced horizontal B-scans, excluding the LC insertion area under Bruch's membrane and scleral rim. LCD was measured in 74 of 81 eyes (91.36%); LCT in 60/81 (75.3%); ODS in 81/81 (100%). CRF was poorly, but significantly, correlated with LCT (Pearson's R = 0.264; P = 0.045). IOPcc, IOPg, CH, and ocular biometrics variables were poorly (non-significantly) correlated with LCD, LCT, and ODS. CRF was poorly but directly correlated with LCT. No association was detected between CH or ocular biometric variables and ODS, LCD, or LCT.

  2. Impact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients.

    PubMed

    Chansangpetch, Sunee; Panpruk, Rawiphan; Manassakorn, Anita; Tantisevi, Visanee; Rojanapongpun, Prin; Hurst, Cameron P; Lin, Shan C

    2017-10-01

    We evaluated the impact of myopia on corneal biomechanical properties in primary open-angle glaucoma (POAG) and nonglaucoma patients, and the effect of modification of glaucoma on myopic eyes. This cross-sectional study included 66 POAG eyes (33 myopia, 33 nonmyopia) and 66 normal eyes (33 myopia, 33 nonmyopia). Seven corneal biomechanical parameters were measured by ultra-high-speed Scheimpflug imaging, including corneal deformation amplitude (CDA), inward/outward corneal applanation length (ICA, OCA), inward/outward corneal velocity (ICV, OCV), radius, and peak distance (PD). Mean age (SD) of the 65 male (49%) and 67 female (51%) patients was 59 (9.82) years. Myopia was associated with significantly higher CDA (adjusted effect = 0.104, P = 0.001) and lower OCV (adjusted effect = -0.105, P < 0.001) in the POAG group. Within the nonglaucoma group, myopic eyes had a significantly lower OCV (adjusted effect = -0.086, P < 0.001) and higher CDA (adjusted effect = 0.079, P = 0.001). All parameters except PD suggested that glaucoma modified the effect of myopia on corneal biomechanics. Percentage differences in the adjusted myopic effect between POAG and nonglaucoma patients was 31.65, 27.27, 31.65, 50.00, 22.09, and 60.49 for CDA, ICA, OCA, ICV, OCV, and radius, respectively. Myopia had a significant impact on corneal biomechanical properties in the POAG and nonglaucoma groups. The differences in corneal biomechanical parameters suggest that myopia is correlated with significantly lower ocular rigidity. POAG may enhance the effects of myopia on most of these parameters.

  3. Impact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients

    PubMed Central

    Panpruk, Rawiphan; Manassakorn, Anita; Tantisevi, Visanee; Rojanapongpun, Prin; Hurst, Cameron P.; Lin, Shan C.

    2017-01-01

    Purpose We evaluated the impact of myopia on corneal biomechanical properties in primary open-angle glaucoma (POAG) and nonglaucoma patients, and the effect of modification of glaucoma on myopic eyes. Methods This cross-sectional study included 66 POAG eyes (33 myopia, 33 nonmyopia) and 66 normal eyes (33 myopia, 33 nonmyopia). Seven corneal biomechanical parameters were measured by ultra-high-speed Scheimpflug imaging, including corneal deformation amplitude (CDA), inward/outward corneal applanation length (ICA, OCA), inward/outward corneal velocity (ICV, OCV), radius, and peak distance (PD). Results Mean age (SD) of the 65 male (49%) and 67 female (51%) patients was 59 (9.82) years. Myopia was associated with significantly higher CDA (adjusted effect = 0.104, P = 0.001) and lower OCV (adjusted effect = −0.105, P < 0.001) in the POAG group. Within the nonglaucoma group, myopic eyes had a significantly lower OCV (adjusted effect = −0.086, P < 0.001) and higher CDA (adjusted effect = 0.079, P = 0.001). All parameters except PD suggested that glaucoma modified the effect of myopia on corneal biomechanics. Percentage differences in the adjusted myopic effect between POAG and nonglaucoma patients was 31.65, 27.27, 31.65, 50.00, 22.09, and 60.49 for CDA, ICA, OCA, ICV, OCV, and radius, respectively. Conclusions Myopia had a significant impact on corneal biomechanical properties in the POAG and nonglaucoma groups. The differences in corneal biomechanical parameters suggest that myopia is correlated with significantly lower ocular rigidity. POAG may enhance the effects of myopia on most of these parameters. PMID:28979996

  4. In vitro method for assessing the biomechanics of the patellofemoral joint following total knee arthroplasty.

    PubMed

    Coles, L G; Gheduzzi, S; Miles, A W

    2014-12-01

    The patellofemoral joint is a common site of pain and failure following total knee arthroplasty. A contributory factor may be adverse patellofemoral biomechanics. Cadaveric investigations are commonly used to assess the biomechanics of the joint, but are associated with high inter-specimen variability and often cannot be carried out at physiological levels of loading. This study aimed to evaluate the suitability of a novel knee simulator for investigating patellofemoral joint biomechanics. This simulator specifically facilitated the extended assessment of patellofemoral joint biomechanics under physiological levels of loading. The simulator allowed the knee to move in 6 degrees of freedom under quadriceps actuation and included a simulation of the action of the hamstrings. Prostheses were implanted on synthetic bones and key soft tissues were modelled with a synthetic analogue. In order to evaluate the physiological relevance and repeatability of the simulator, measurements were made of the quadriceps force and the force, contact area and pressure within the patellofemoral joint using load cells, pressure-sensitive film, and a flexible pressure sensor. The results were in agreement with those previously reported in the literature, confirming that the simulator is able to provide a realistic physiological loading situation. Under physiological loading, average standard deviations of force and area measurements were substantially lower and comparable to those reported in previous cadaveric studies, respectively. The simulator replicates the physiological environment and has been demonstrated to allow the initial investigation of factors affecting patellofemoral biomechanics following total knee arthroplasty. © IMechE 2014.

  5. The Influence of Lower Extremity Lean Mass on Landing Biomechanics During Prolonged Exercise.

    PubMed

    Montgomery, Melissa M; Tritsch, Amanda J; Cone, John R; Schmitz, Randy J; Henson, Robert A; Shultz, Sandra J

    2017-08-01

      The extent to which lower extremity lean mass (LELM) relative to total body mass influences one's ability to maintain safe landing biomechanics during prolonged exercise when injury incidence increases is unknown.   To examine the influence of LELM on (1) pre-exercise lower extremity biomechanics and (2) changes in biomechanics during an intermittent exercise protocol (IEP) and (3) determine whether these relationships differ by sex. We hypothesized that less LELM would predict higher-risk baseline biomechanics and greater changes toward higher-risk biomechanics during the IEP.   Cohort study.   Controlled laboratory.   A total of 59 athletes (30 men: age = 20.3 ± 2.0 years, height = 1.79 ± 0.05 m, mass = 75.2 ± 7.2 kg; 29 women: age = 20.6 ± 2.3 years, height = 1.67 ± 0.08 m, mass = 61.8 ± 9.0 kg) participated.   Before completing an individualized 90-minute IEP designed to mimic a soccer match, participants underwent dual-energy x-ray absorptiometry testing for LELM.   Three-dimensional lower extremity biomechanics were measured during drop-jump landings before the IEP and every 15 minutes thereafter. A previously reported principal components analysis reduced 40 biomechanical variables to 11 factors. Hierarchical linear modeling analysis then determined the extent to which sex and LELM predicted the baseline score and the change in each factor over time.   Lower extremity lean mass did not influence baseline biomechanics or the changes over time. Sex influenced the biomechanical factor representing knee loading at baseline (P = .04) and the changes in the anterior cruciate ligament-loading factor over time (P = .03). The LELM had an additional influence only on women who possessed less LELM (P = .03 and .02, respectively).   Lower extremity lean mass influenced knee loading during landing in women but not in men. The effect appeared to be stronger in women with less LELM. Continually decreasing knee loading over time may reflect a

  6. A public dataset of running biomechanics and the effects of running speed on lower extremity kinematics and kinetics

    PubMed Central

    Fukuchi, Claudiane A.; Duarte, Marcos

    2017-01-01

    Background The goals of this study were (1) to present the set of data evaluating running biomechanics (kinematics and kinetics), including data on running habits, demographics, and levels of muscle strength and flexibility made available at Figshare (DOI: 10.6084/m9.figshare.4543435); and (2) to examine the effect of running speed on selected gait-biomechanics variables related to both running injuries and running economy. Methods The lower-extremity kinematics and kinetics data of 28 regular runners were collected using a three-dimensional (3D) motion-capture system and an instrumented treadmill while the subjects ran at 2.5 m/s, 3.5 m/s, and 4.5 m/s wearing standard neutral shoes. Results A dataset comprising raw and processed kinematics and kinetics signals pertaining to this experiment is available in various file formats. In addition, a file of metadata, including demographics, running characteristics, foot-strike patterns, and muscle strength and flexibility measurements is provided. Overall, there was an effect of running speed on most of the gait-biomechanics variables selected for this study. However, the foot-strike patterns were not affected by running speed. Discussion Several applications of this dataset can be anticipated, including testing new methods of data reduction and variable selection; for educational purposes; and answering specific research questions. This last application was exemplified in the study’s second objective. PMID:28503379

  7. A public dataset of running biomechanics and the effects of running speed on lower extremity kinematics and kinetics.

    PubMed

    Fukuchi, Reginaldo K; Fukuchi, Claudiane A; Duarte, Marcos

    2017-01-01

    The goals of this study were (1) to present the set of data evaluating running biomechanics (kinematics and kinetics), including data on running habits, demographics, and levels of muscle strength and flexibility made available at Figshare (DOI: 10.6084/m9.figshare.4543435); and (2) to examine the effect of running speed on selected gait-biomechanics variables related to both running injuries and running economy. The lower-extremity kinematics and kinetics data of 28 regular runners were collected using a three-dimensional (3D) motion-capture system and an instrumented treadmill while the subjects ran at 2.5 m/s, 3.5 m/s, and 4.5 m/s wearing standard neutral shoes. A dataset comprising raw and processed kinematics and kinetics signals pertaining to this experiment is available in various file formats. In addition, a file of metadata, including demographics, running characteristics, foot-strike patterns, and muscle strength and flexibility measurements is provided. Overall, there was an effect of running speed on most of the gait-biomechanics variables selected for this study. However, the foot-strike patterns were not affected by running speed. Several applications of this dataset can be anticipated, including testing new methods of data reduction and variable selection; for educational purposes; and answering specific research questions. This last application was exemplified in the study's second objective.

  8. Biomechanical Changes in the Sclera of Monkey Eyes Exposed to Chronic IOP Elevations

    PubMed Central

    Girard, Michaël J. A.; Suh, J.-K. Francis; Bottlang, Michael; Burgoyne, Claude F.

    2011-01-01

    Purpose. To characterize scleral biomechanics in both eyes of eight monkeys in which chronic intraocular pressure (IOP) elevation was induced in one eye. Methods. Each posterior sclera was mounted on a pressurization apparatus, IOP was elevated from 5 to 45 mm Hg while the 3D displacements of the scleral surface were measured by speckle interferometry. Finite element (FE) models of each scleral shell were constructed that incorporated stretch-induced stiffening and multidirectionality of the collagen fibers. FE model predictions were then iteratively matched to experimental displacements to extract unique sets of scleral biomechanical properties. Results. For all eyes, the posterior sclera exhibited inhomogeneous, anisotropic, nonlinear biomechanical behavior. Biomechanical changes caused by chronic IOP elevation were complex and specific to each subject. Specifically: (1) Glaucomatous eyes in which the contralateral normal eyes displayed large modulus or thickness were less prone to biomechanical changes; (2) glaucomatous scleral modulus associated with an IOP of 10 mm Hg decreased (when compared with that of the contralateral normal) after minimal chronic IOP elevation; (3) glaucomatous scleral modulus associated with IOPs of 30 and 45 mm Hg increased (when compared with that of the contralateral normal) after moderate IOP elevation; and (4) FE-based estimates of collagen fiber orientation demonstrated no change in the glaucomatous eyes. Conclusions. Significant stiffening of the sclera follows exposure to moderate IOP elevations in most eyes. Scleral hypercompliance may precede stiffening or be a unique response to minimal chronic IOP elevation in some eyes. These biomechanical changes are likely to be the result of scleral extracellular matrix remodeling. PMID:21519033

  9. Surface driven biomechanical breast image registration

    NASA Astrophysics Data System (ADS)

    Eiben, Björn; Vavourakis, Vasileios; Hipwell, John H.; Kabus, Sven; Lorenz, Cristian; Buelow, Thomas; Williams, Norman R.; Keshtgar, M.; Hawkes, David J.

    2016-03-01

    Biomechanical modelling enables large deformation simulations of breast tissues under different loading conditions to be performed. Such simulations can be utilised to transform prone Magnetic Resonance (MR) images into a different patient position, such as upright or supine. We present a novel integration of biomechanical modelling with a surface registration algorithm which optimises the unknown material parameters of a biomechanical model and performs a subsequent regularised surface alignment. This allows deformations induced by effects other than gravity, such as those due to contact of the breast and MR coil, to be reversed. Correction displacements are applied to the biomechanical model enabling transformation of the original pre-surgical images to the corresponding target position. The algorithm is evaluated for the prone-to-supine case using prone MR images and the skin outline of supine Computed Tomography (CT) scans for three patients. A mean target registration error (TRE) of 10:9 mm for internal structures is achieved. For the prone-to-upright scenario, an optical 3D surface scan of one patient is used as a registration target and the nipple distances after alignment between the transformed MRI and the surface are 10:1 mm and 6:3 mm respectively.

  10. Neck muscle biomechanics and neural control.

    PubMed

    Fice, Jason Bradley; Siegmund, Gunter P; Blouin, Jean-Sebastien

    2018-04-18

    The mechanics, morphometry, and geometry of our joints, segments and muscles are fundamental biomechanical properties intrinsic to human neural control. The goal of our study was to investigate if the biomechanical actions of individual neck muscles predicts their neural control. Specifically, we compared the moment direction & variability produced by electrical stimulation of a neck muscle (biomechanics) to their preferred activation direction & variability (neural control). Subjects sat upright with their head fixed to a 6-axis load cell and their torso restrained. Indwelling wire electrodes were placed into the sternocleidomastoid (SCM), splenius capitis (SPL), and semispinalis capitis (SSC) muscles. The electrically stimulated direction was defined as the moment direction produced when a current (2-19mA) was passed through each muscle's electrodes. Preferred activation direction was defined as the vector sum of the spatial tuning curve built from RMS EMG when subjects produced isometric moments at 7.5% and 15% of their maximum voluntary contraction (MVC) in 26 3D directions. The spatial tuning curves at 15% MVC were well-defined (unimodal, p<0.05) and their preferred directions were 23, 39, & 21{degree sign} different from their electrically stimulated directions for the SCM, SPL, and SSC respectively (p<0.05). Intra-subject variability was smaller in electrically stimulated moment directions when compared to voluntary preferred directions, and intra-subject variability decreased with increased activation levels. Our findings show that the neural control of neck muscles is not based solely on optimizing individual muscle biomechanics but, as activation increases, biomechanical constraints in part dictate the activation of synergistic neck muscles.

  11. CURRENT CONCEPTS IN BIOMECHANICAL INTERVENTIONS FOR PATELLOFEMORAL PAIN

    PubMed Central

    Meira, Erik P.

    2016-01-01

    Patellofemoral pain (PFP) has historically been a complex and enigmatic issue. Many of the factors thought to relate to PFP remain after patients' symptoms have resolved making their clinical importance difficult to determine. The tissue homeostasis model proposed by Dye in 2005 can assist with understanding and implementing biomechanical interventions for PFP. Under this model, the goal of interventions for PFP should be to re-establish patellofemoral joint (PFJ) homeostasis through a temporary alteration of load to the offended tissue, followed by incrementally restoring the envelope of function to the baseline level or higher. High levels of PFJ loads, particularly in the presence of an altered PFJ environment, are thought to be a factor in the development of PFP. Clinical interventions often aim to alter the biomechanical patterns that are thought to result in elevated PFJ loads while concurrently increasing the load tolerance capabilities of the tissue through therapeutic exercise. Biomechanics may play a role in PFJ load modification not only when addressing proximal and distal components, but also when considering the involvement of more local factors such as the quadriceps musculature. Biomechanical considerations should consider the entire kinetic chain including the hip and the foot/ankle complex, however the beneficial effects of these interventions may not be the result of long-term biomechanical changes. Biomechanical alterations may be achieved through movement retraining, but the interventions likely need to be task-specific to alter movement patterns. The purpose of this commentary is to describe biomechanical interventions for the athlete with PFP to encourage a safe and complete return to sport. Level of Evidence 5 PMID:27904791

  12. Biomechanically Engineered Athletes.

    ERIC Educational Resources Information Center

    Perry, Tekla S.

    1991-01-01

    The real-world meeting of electronics, computer monitoring, control systems, and mathematics, introduced in the context of sports, is described. Recent advances in the field of biomechanics and its use in improving athletic performance are discussed. (KR)

  13. Biomechanical analysis of materials handling manipulators in short distance transfers of moderate mass objects: joint strength, spine forces and muscular antagonism.

    PubMed

    Nussbaum, M A; Chaffin, D B; Baker, G

    1999-12-01

    Although often suggested as a control measure to alleviate musculoskeletal stresses, the use of mechanical assistance devices (i.e. manipulators) in load transfers has not been extensively studied. Without data describing the biomechanical effects of such devices, justification for decisions regarding implementation of such tools is difficult. An experimental study of two types of mechanical manipulators (articulated arm and overhead hoist) was conducted to determine whether biomechanical stresses, and hence injury risk, would be alleviated. Short distance transfers of loads with moderate mass were performed both manually and with manipulator assistance under a variety of task conditions. Using analysis and output from new dynamic torso models, strength demands at the shoulders and low back, lumbar spine forces, and lumbar muscle antagonism were determined. Strength requirements decreased significantly at both the shoulders and low back when using either manipulator in comparison with similar transfers performed manually. Peak spine compression and anterior-posterior (a-p) shear forces were reduced by about 40% on average, and these reductions were shown to be primarily caused by decreases in hand forces and resultant spinal moments. Two metrics of muscular antagonism were defined, and analysis showed that torso muscle antagonism was largest overall when using the hoist. The results overall suggest that hoist-assisted transfers, although better in reducing spine compression forces, may impose relatively higher demands on coordination and/or stability at extreme heights or with torso twisting motions. The relatively higher strength requirements and spine compression associated with the articulated arm may be a result of the high inertia of the system. Potential benefits of practice and training are discussed, and conclusions regarding implementation of mechanical manipulators are given.

  14. Speciation through the lens of biomechanics: locomotion, prey capture and reproductive isolation

    PubMed Central

    Rogers, Sean M.; Langerhans, R. Brian; Jamniczky, Heather A.; Lauder, George V.; Stewart, William J.; Martin, Christopher H.; Reznick, David N.

    2016-01-01

    Speciation is a multifaceted process that involves numerous aspects of the biological sciences and occurs for multiple reasons. Ecology plays a major role, including both abiotic and biotic factors. Whether populations experience similar or divergent ecological environments, they often adapt to local conditions through divergence in biomechanical traits. We investigate the role of biomechanics in speciation using fish predator–prey interactions, a primary driver of fitness for both predators and prey. We highlight specific groups of fishes, or specific species, that have been particularly valuable for understanding these dynamic interactions and offer the best opportunities for future studies that link genetic architecture to biomechanics and reproductive isolation (RI). In addition to emphasizing the key biomechanical techniques that will be instrumental, we also propose that the movement towards linking biomechanics and speciation will include (i) establishing the genetic basis of biomechanical traits, (ii) testing whether similar and divergent selection lead to biomechanical divergence, and (iii) testing whether/how biomechanical traits affect RI. Future investigations that examine speciation through the lens of biomechanics will propel our understanding of this key process. PMID:27629033

  15. What Factors Influence the Biomechanical Properties of Allograft Tissue for ACL Reconstruction? A Systematic Review.

    PubMed

    Lansdown, Drew A; Riff, Andrew J; Meadows, Molly; Yanke, Adam B; Bach, Bernard R

    2017-10-01

    stiffness values. Various chemical sterilization measures were also associated with negative effects on biomechanical properties. Prolonged freezing decreased load to failure, ultimate stress, and ultimate strain. Up to eight freeze-thaw cycles did not lead to differences in biomechanical properties of cadaveric grafts. Regional differences were noted in patellar tendon grafts, with the central third showing the highest load to failure and stiffness. Graft diameter strongly contributed to load-to-failure measurements. Age older than 40 years, and especially older than 65 years, negatively impacted biomechanical properties, whereas gender had minimal effect on the properties of allograft tissue. Biologic adjuncts show potential for improving in vivo properties of allograft tissue. Future clinical studies on allograft ACL reconstruction should investigate in vivo graft performance with standardized allograft processing and preparation methods that limit the negative effects on the biomechanical properties of tissue. Additionally, biologic adjuncts may improve the biomechanical properties of allograft tissue, although future preclinical and clinical studies are necessary to clarify the role of these treatments. Based on the findings of this systematic review that emphasize biomechanical properties of ACL allografts, surgeons should favor the use of central third patellar tendon or looped soft tissue grafts, maximize graft cross-sectional area, and favor grafts from donors younger than 40 years of age while avoiding grafts subjected to radiation doses > 20 kGy, chemical processing, or greater than eight freeze-thaw cycles.

  16. Biomechanical analysis of posteromedial tibial plateau split fracture fixation.

    PubMed

    Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang

    2011-01-01

    The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Biomechanics of an orthosis-managed cranial cruciate ligament-deficient canine stifle joint predicted by use of a computer model.

    PubMed

    Bertocci, Gina E; Brown, Nathan P; Mich, Patrice M

    2017-01-01

    OBJECTIVE To evaluate effects of an orthosis on biomechanics of a cranial cruciate ligament (CrCL)-deficient canine stifle joint by use of a 3-D quasistatic rigid-body pelvic limb computer model simulating the stance phase of gait and to investigate influences of orthosis hinge stiffness (durometer). SAMPLE A previously developed computer simulation model for a healthy 33-kg 5-year-old neutered Golden Retriever. PROCEDURES A custom stifle joint orthosis was implemented in the CrCL-deficient pelvic limb computer simulation model. Ligament loads, relative tibial translation, and relative tibial rotation in the orthosis-stabilized stifle joint (baseline scenario; high-durometer hinge]) were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. Sensitivity analysis was conducted to evaluate the influence of orthosis hinge stiffness on model outcome measures. RESULTS The orthosis decreased loads placed on the caudal cruciate and lateral collateral ligaments and increased load placed on the medial collateral ligament, compared with loads for the CrCL-intact stifle joint. Ligament loads were decreased in the orthosis-managed CrCL-deficient stifle joint, compared with loads for the CrCL-deficient stifle joint. Relative tibial translation and rotation decreased but were not eliminated after orthosis management. Increased orthosis hinge stiffness reduced tibial translation and rotation, whereas decreased hinge stiffness increased internal tibial rotation, compared with values for the baseline scenario. CONCLUSIONS AND CLINICAL RELEVANCE Stifle joint biomechanics were improved following orthosis implementation, compared with biomechanics of the CrCL-deficient stifle joint. Orthosis hinge stiffness influenced stifle joint biomechanics. An orthosis may be a viable option to stabilize a CrCL-deficient canine stifle joint.

  18. Matrix Metalloproteinase 9 (MMP-9) Regulates Vein Wall Biomechanics in Murine Thrombus Resolution

    PubMed Central

    Nguyen, Khanh P.; McGilvray, Kirk C.; Puttlitz, Christian M.; Mukhopadhyay, Subhradip; Chabasse, Christine; Sarkar, Rajabrata

    2015-01-01

    Objective Deep venous thrombosis is a common vascular problem with long-term complications including post-thrombotic syndrome. Post-thrombotic syndrome consists of leg pain, swelling and ulceration that is related to incomplete or maladaptive resolution of the venous thrombus as well as loss of compliance of the vein wall. We examine the role of metalloproteinase-9 (MMP-9), a gene important in extracellular remodeling in other vascular diseases, in mediating thrombus resolution and biomechanical changes of the vein wall. Methods and Results The effects of targeted deletion of MMP-9 were studied in an in vivo murine model of thrombus resolution using the FVB strain of mice. MMP-9 expression and activity significantly increased on day 3 after DVT. The lack of MMP-9 impaired thrombus resolution by 27% and this phenotype was rescued by the transplantation of wildtype bone marrow cells. Using novel biomechanical techniques, we demonstrated that the lack of MMP-9 significantly decreased thrombus-induced loss of vein wall compliance. Biomechanical analysis of the contribution of individual structural components showed that MMP-9 affected the elasticity of the extracellular matrix and collagen-elastin fibers. Biochemical and histological analyses correlated with these biomechanical effects as thrombi of mice lacking MMP-9 had significantly fewer macrophages and collagen as compared to those of wildtype mice. Conclusions MMP-9 mediates thrombus-induced loss of vein wall compliance by increasing stiffness of the extracellular matrix and collagen-elastin fibers during thrombus resolution. MMP-9 also mediates macrophage and collagen content of the resolving thrombus and bone-marrow derived MMP-9 plays a role in resolution of thrombus mass. These disparate effects of MMP-9 on various aspects of thrombus illustrate the complexity of individual protease function on biomechanical and morphometric aspects of thrombus resolution. PMID:26406902

  19. Muscular activity and its relationship to biomechanics and human performance

    NASA Technical Reports Server (NTRS)

    Ariel, Gideon

    1994-01-01

    The purpose of this manuscript is to address the issue of muscular activity, human motion, fitness, and exercise. Human activity is reviewed from the historical perspective as well as from the basics of muscular contraction, nervous system controls, mechanics, and biomechanical considerations. In addition, attention has been given to some of the principles involved in developing muscular adaptations through strength development. Brief descriptions and findings from a few studies are included. These experiments were conducted in order to investigate muscular adaptation to various exercise regimens. Different theories of strength development were studied and correlated to daily human movements. All measurement tools used represent state of the art exercise equipment and movement analysis. The information presented here is only a small attempt to understand the effects of exercise and conditioning on Earth with the objective of leading to greater knowledge concerning human responses during spaceflight. What makes life from nonliving objects is movement which is generated and controlled by biochemical substances. In mammals. the controlled activators are skeletal muscles and this muscular action is an integral process composed of mechanical, chemical, and neurological processes resulting in voluntary and involuntary motions. The scope of this discussion is limited to voluntary motion.

  20. Biomechanics of the thorax - research evidence and clinical expertise.

    PubMed

    Lee, Diane Gail

    2015-07-01

    Understanding the biomechanics of the thorax is critical for understanding its role in multiple conditions since the thorax is part of many integrated systems including the musculoskeletal, respiratory, cardiac, digestive and urogynecological. The thorax is also an integrated system within itself and an element of the whole body/person. Therefore, understanding the biomechanics of the thorax is fundamental to all forms of treatment for multiple conditions. The interpretation of movement examination findings depends on one's view of optimal biomechanics and the influential factors. This article will provide a synopsis of the current state of research evidence as well as observations from clinical experience pertaining to the biomechanics of the thorax in order to help clinicians organise this knowledge and facilitate evidence-based and informed management of the, often complex, patient with or without thoracic pain and impairment. The integrated systems model (ISM) will be introduced as a way to determine when the noted biomechanical findings are relevant to a patient's clinical presentation.

  1. Biomechanical interpretation of a free-breathing lung motion model

    NASA Astrophysics Data System (ADS)

    Zhao, Tianyu; White, Benjamin; Moore, Kevin L.; Lamb, James; Yang, Deshan; Lu, Wei; Mutic, Sasa; Low, Daniel A.

    2011-12-01

    The purpose of this paper is to develop a biomechanical model for free-breathing motion and compare it to a published heuristic five-dimensional (5D) free-breathing lung motion model. An ab initio biomechanical model was developed to describe the motion of lung tissue during free breathing by analyzing the stress-strain relationship inside lung tissue. The first-order approximation of the biomechanical model was equivalent to a heuristic 5D free-breathing lung motion model proposed by Low et al in 2005 (Int. J. Radiat. Oncol. Biol. Phys. 63 921-9), in which the motion was broken down to a linear expansion component and a hysteresis component. To test the biomechanical model, parameters that characterize expansion, hysteresis and angles between the two motion components were reported independently and compared between two models. The biomechanical model agreed well with the heuristic model within 5.5% in the left lungs and 1.5% in the right lungs for patients without lung cancer. The biomechanical model predicted that a histogram of angles between the two motion components should have two peaks at 39.8° and 140.2° in the left lungs and 37.1° and 142.9° in the right lungs. The data from the 5D model verified the existence of those peaks at 41.2° and 148.2° in the left lungs and 40.1° and 140° in the right lungs for patients without lung cancer. Similar results were also observed for the patients with lung cancer, but with greater discrepancies. The maximum-likelihood estimation of hysteresis magnitude was reported to be 2.6 mm for the lung cancer patients. The first-order approximation of the biomechanical model fit the heuristic 5D model very well. The biomechanical model provided new insights into breathing motion with specific focus on motion trajectory hysteresis.

  2. Robot-aided therapy on the upper limb of subacute and chronic stroke patients: a biomechanical approach.

    PubMed

    Mazzoleni, S; Filippi, M; Carrozza, M C; Posteraro, F; Puzzolante, L; Falchi, E

    2011-01-01

    The goal of this study is to propose a methodology for evaluating recovery mechanisms in subacute and chronic post-stroke patients after a robot-aided upper-limb therapy, using a set of biomechanical parameters. Fifty-six post-stroke subjects, thirteen subacute and forty-three chronic patients participated in the study. A 2 dof robotic system, implementing an "assist-as-needed" control strategy, was used. Biomechanical parameters related (i) to the speed measured at the robot's end-effector and (ii) to the movement's smoothness were computed. Outcome clinical measures show a decrease in motor impairment after the treatment both in chronic and subacute patients. All the biomechanical parameters show an improvement between admission and discharge. Our results show that the robot-aided training can contribute to reduce the motor impairment in both subacute and chronic patients and identify neurophysiological mechanisms underlying the different stages of motor recovery. © 2011 IEEE

  3. Speciation through the lens of biomechanics: locomotion, prey capture and reproductive isolation.

    PubMed

    Higham, Timothy E; Rogers, Sean M; Langerhans, R Brian; Jamniczky, Heather A; Lauder, George V; Stewart, William J; Martin, Christopher H; Reznick, David N

    2016-09-14

    Speciation is a multifaceted process that involves numerous aspects of the biological sciences and occurs for multiple reasons. Ecology plays a major role, including both abiotic and biotic factors. Whether populations experience similar or divergent ecological environments, they often adapt to local conditions through divergence in biomechanical traits. We investigate the role of biomechanics in speciation using fish predator-prey interactions, a primary driver of fitness for both predators and prey. We highlight specific groups of fishes, or specific species, that have been particularly valuable for understanding these dynamic interactions and offer the best opportunities for future studies that link genetic architecture to biomechanics and reproductive isolation (RI). In addition to emphasizing the key biomechanical techniques that will be instrumental, we also propose that the movement towards linking biomechanics and speciation will include (i) establishing the genetic basis of biomechanical traits, (ii) testing whether similar and divergent selection lead to biomechanical divergence, and (iii) testing whether/how biomechanical traits affect RI. Future investigations that examine speciation through the lens of biomechanics will propel our understanding of this key process. © 2016 The Author(s).

  4. Enhanced Combined Tomography and Biomechanics Data for Distinguishing Forme Fruste Keratoconus.

    PubMed

    Luz, Allan; Lopes, Bernardo; Hallahan, Katie M; Valbon, Bruno; Ramos, Isaac; Faria-Correia, Fernando; Schor, Paulo; Dupps, William J; Ambrósio, Renato

    2016-07-01

    To evaluate the performance of the Ocular Response Analyzer (ORA) (Reichert Ophthalmic Instruments, Depew, NY) variables and Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) tomographic parameters in differentiating forme fruste keratoconus (FFKC) from normal corneas, and to assess a combined biomechanical and tomographic parameter to improve outcomes. Seventy-six eyes of 76 normal patients and 21 eyes of 21 patients with FFKC were included in the study. Fifteen variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior and 37 ORA waveform parameters were tested. Sixteen tomographic parameters from Pentacam HR were tested. Logistic regression was used to produce a combined biomechanical and tomography linear model. Differences between groups were assessed by the Mann-Whitney U test. The area under the receiver operating characteristics curve (AUROC) was used to compare diagnostic performance. No statistically significant differences were found in age, thinnest point, central corneal thickness, and maximum keratometry between groups. Twenty-one parameters showed significant differences between the FFKC and control groups. Among the ORA waveform measurements, the best parameters were those related to the area under the first peak, p1area1 (AUROC, 0.717 ± 0.065). Among the investigator ORA variables, a measure incorporating the pressure-deformation relationship of the entire response cycle was the best predictor (hysteresis loop area, AUROC, 0.688 ± 0.068). Among tomographic parameters, Belin/Ambrósio display showed the highest predictive value (AUROC, 0.91 ± 0.057). A combination of parameters showed the best result (AUROC, 0.953 ± 0.024) outperforming individual parameters. Tomographic and biomechanical parameters demonstrated the ability to differentiate FFKC from normal eyes. A combination of both types of information further improved predictive value. [J Refract Surg. 2016;32(7):479-485.]. Copyright

  5. Patients With Insertional Achilles Tendinopathy Exhibit Differences in Ankle Biomechanics as Opposed to Strength and Range of Motion.

    PubMed

    Chimenti, Ruth L; Flemister, A Samuel; Tome, Joshua; McMahon, James M; Houck, Jeff R

    2016-12-01

    Study Design Controlled laboratory study; cross-sectional. Background Little is known about ankle range of motion (ROM) and strength among patients with insertional Achilles tendinopathy (IAT) and whether limited ankle ROM and plantar flexor weakness impact IAT symptom severity. Objectives The purposes of the study were (1) to examine whether participants with IAT exhibit limited non-weight-bearing dorsiflexion ROM, reduced plantar flexor strength, and/or altered ankle biomechanics during stair ascent; and (2) to determine which impairments are associated with symptom severity. Methods Participants included 20 patients with unilateral IAT (mean ± SD age, 59 ± 8 years; 55% female) and 20 individuals without tendinopathy (age, 58.2 ± 8.5 years; 55% female). A dynamometer was used to measure non-weight-bearing ROM and isometric plantar flexor strength. Three-dimensional motion analysis was used to quantify ankle biomechanics during stair ascent. End-range dorsiflexion was quantified as the percentage of non-weight-bearing dorsiflexion used during stair ascent. Group differences were compared using 2-way and 1-way analyses of variance. Pearson correlations were used to test for associations among dependent variables and symptom severity. Results Groups differed in ankle biomechanics, but not non-weight-bearing ROM or strength. During stair ascent, the IAT group used greater end-range dorsiflexion (P = .03), less plantar flexion (P = .02), and lower peak ankle plantar flexor power (P = .01) than the control group. Higher end-range dorsiflexion and lower ankle power during stair ascent were associated with greater symptom severity (P<.05). Conclusion Patients with IAT do not experience restrictions in non-weight-bearing dorsiflexion ROM or isometric plantar flexor strength. However, altered ankle biomechanics during stair ascent were linked with greater symptom severity and likely contribute to decreased function. J Orthop Sports Phys Ther 2016;46(12):1051-1060. Epub

  6. Biomechanics of the Optic Nerve Sheath in VIIP Syndrome

    NASA Technical Reports Server (NTRS)

    Ethier, C. Ross; Raykin, Julia; Gleason, Rudy; Mulugeta, Lealem; Myers, Jerry; Nelson, Emily; Samuels, Brian C.

    2014-01-01

    Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important

  7. Issues Related to Measuring and Interpreting Objectively Measured Sedentary Behavior Data

    ERIC Educational Resources Information Center

    Janssen, Xanne; Cliff, Dylan P.

    2015-01-01

    The use of objective measures of sedentary behavior has increased over the past decade; however, as is the case for objectively measured physical activity, methodological decisions before and after data collection are likely to influence the outcomes. The aim of this article is to review the evidence on different methodological decisions made by…

  8. Vocal fold proteoglycans and their influence on biomechanics.

    PubMed

    Gray, S D; Titze, I R; Chan, R; Hammond, T H

    1999-06-01

    To examine the interstitial proteins of the vocal fold and their influence on the biomechanical properties of that tissue. Anatomic study of the lamina propria of human cadaveric vocal folds combined with some viscosity testing. Identification of proteoglycans is performed with histochemical staining. Quantitative analysis is performed using an image analysis system. A rheometer is used for viscosity testing. Three-dimensional rendering program is used for the computer images. Proteoglycans play an important role in tissue biomechanics. Hyaluronic acid is a key molecule that affects viscosity. The proteoglycans of the lamina propria have important biological and biomechanical effects. The role of hyaluronic acid in determining tissue viscosity is emphasized. Viscosity, its effect on phonatory threshold pressure and energy expended due to phonation is discussed. Proteoglycans, particularly hyaluronic acid, play important roles in determining biomechanical properties of tissue oscillation. Future research will likely make these proteins of important therapeutic interest.

  9. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    PubMed

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI

  10. APPLICATION OF DATA QUALITY OBJECTIVES AND MEASUREMENT QUALITY OBJECTIVES TO RESEARCH PROJECTS

    EPA Science Inventory

    The paper assists systematic planning for research projects. It presents planning concepts in terms that have some utility for researchers. For example, measurement quality objectives are more familiar to researchers than data quality objectives because these quality criteria are...

  11. Biomechanical Analysis of T2 Exercise

    NASA Technical Reports Server (NTRS)

    DeWitt, John K.; Ploutz-Snyder, Lori; Everett, Meghan; Newby, Nathaniel; Scott-Pandorf, Melissa; Guilliams, Mark E.

    2010-01-01

    Crewmembers regularly perform treadmill exercise on the ISS. With the implementation of T2 on ISS, there is now the capacity to obtain ground reaction force (GRF) data GRF data combined with video motion data allows biomechanical analyses to occur that generate joint torque estimates from exercise conditions. Knowledge of how speed and load influence joint torque will provide quantitative information on which exercise prescriptions can be based. The objective is to determine the joint kinematics, ground reaction forces, and joint kinetics associated with treadmill exercise on the ISS. This study will: 1) Determine if specific exercise speed and harness load combinations are superior to others in exercise benefit; and 2) Aid in the design of exercise prescriptions that will be most beneficial in maintaining crewmember health.

  12. MRI-based biomechanical parameters for carotid artery plaque vulnerability assessment.

    PubMed

    Speelman, Lambert; Teng, Zhongzhao; Nederveen, Aart J; van der Lugt, Aad; Gillard, Jonathan H

    2016-03-01

    Carotid atherosclerotic plaques are a major cause of ischaemic stroke. The biomechanical environment to which the arterial wall and plaque is subjected to plays an important role in the initiation, progression and rupture of carotid plaques. MRI is frequently used to characterize the morphology of a carotid plaque, but new developments in MRI enable more functional assessment of carotid plaques. In this review, MRI based biomechanical parameters are evaluated on their current status, clinical applicability, and future developments. Blood flow related biomechanical parameters, including endothelial wall shear stress and oscillatory shear index, have been shown to be related to plaque formation. Deriving these parameters directly from MRI flow measurements is feasible and has great potential for future carotid plaque development prediction. Blood pressure induced stresses in a plaque may exceed the tissue strength, potentially leading to plaque rupture. Multi-contrast MRI based stress calculations in combination with tissue strength assessment based on MRI inflammation imaging may provide a plaque stress-strength balance that can be used to assess the plaque rupture risk potential. Direct plaque strain analysis based on dynamic MRI is already able to identify local plaque displacement during the cardiac cycle. However, clinical evidence linking MRI strain to plaque vulnerability is still lacking. MRI based biomechanical parameters may lead to improved assessment of carotid plaque development and rupture risk. However, better MRI systems and faster sequences are required to improve the spatial and temporal resolution, as well as increase the image contrast and signal-to-noise ratio.

  13. A biomechanical and physiological study of office seat and tablet device interaction.

    PubMed

    Weston, Eric; Le, Peter; Marras, William S

    2017-07-01

    Twenty subjects performed typing tasks on a desktop computer and touch-screen tablet in two chairs for an hour each, and the effects of chair, device, and their interactions on each dependent measure were recorded. Biomechanical measures of muscle force, spinal load, and posture were examined, while discomfort was measured via heart rate variability (HRV) and subjective reports. HRV was sensitive enough to differentiate between chair and device interactions. Biomechanically, a lack of seat back mobility forced individuals to maintain an upright seating posture with increased extensor muscle forces and increased spinal compression. Effects were exacerbated by forward flexion upon interaction with a tablet device or by slouching. Office chairs should be designed with both the human and workplace task in mind and allow for reclined postures to off-load the spine. The degree of recline should be limited, however, to prevent decreased lumbar lordosis resulting from posterior hip rotation in highly reclined postures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Phase reversal of biomechanical functions and muscle activity in backward pedaling.

    PubMed

    Ting, L H; Kautz, S A; Brown, D A; Zajac, F E

    1999-02-01

    Computer simulations of pedaling have shown that a wide range of pedaling tasks can be performed if each limb has the capability of executing six biomechanical functions, which are arranged into three pairs of alternating antagonistic functions. An Ext/Flex pair accelerates the limb into extension or flexion, a Plant/Dorsi pair accelerates the foot into plantarflexion or dorsiflexion, and an Ant/Post pair accelerates the foot anteriorly or posteriorly relative to the pelvis. Because each biomechanical function (i.e., Ext, Flex, Plant, Dorsi, Ant, or Post) contributes to crank propulsion during a specific region in the cycle, phasing of a muscle is hypothesized to be a consequence of its ability to contribute to one or more of the biomechanical functions. Analysis of electromyogram (EMG) patterns has shown that this biomechanical framework assists in the interpretation of muscle activity in healthy and hemiparetic subjects during forward pedaling. Simulations show that backward pedaling can be produced with a phase shift of 180 degrees in the Ant/Post pair. No phase shifts in the Ext/Flex and Plant/Dorsi pairs are then necessary. To further test whether this simple yet biomechanically viable strategy may be used by the nervous system, EMGs from 7 muscles in 16 subjects were measured during backward as well as forward pedaling. As predicted, phasing in vastus medialis (VM), tibialis anterior (TA), medial gastrocnemius (MG), and soleus (SL) were unaffected by pedaling direction, with VM and SL contributing to Ext, MG to Plant, and TA to Dorsi. In contrast, phasing in biceps femoris (BF) and semimembranosus (SM) were affected by pedaling direction, as predicted, compatible with their contribution to the directionally sensitive Post function. Phasing of rectus femoris (RF) was also affected by pedaling direction; however, its ability to contribute to the directionally sensitive Ant function may only be expressed in forward pedaling. RF also contributed significantly to

  15. Corneal biomechanical parameters and intraocular pressure: the effect of topical anesthesia

    PubMed Central

    Ogbuehi, Kelechi C

    2012-01-01

    Background The intraocular pressures and biomechanical parameters measured by the ocular response analyzer make the analyzer a useful tool for the diagnosis and management of anterior segment disease. This observational study was designed to investigate the effect of topical anesthesia on the parameters measured by the ocular response analyzer: corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc). Methods Two sets of measurements were made for 78 eyes of 39 subjects, approximately 1 week apart. In session 1, each eye of each subject was randomized into one of three groups: polyvinyl alcohol (0.5%), tetracaine hydrochloride (0.5%), or oxybuprocaine hydrochloride (0.4%). In session 2, eyes that were in the polyvinyl alcohol group in session 1 were assigned to the tetracaine group, those in the tetracaine group in session 1 were assigned to oxybuprocaine group, and those in the oxybuprocaine group in session 1 were assigned to the polyvinyl alcohol group. For both sessions, each subject first had his or her central corneal thickness assessed with a specular microscope, followed by measurements of intraocular pressure and corneal biomechanical parameters with the Ocular Response Analyzer. All measurements were repeated for 2 minutes and 5 minutes following the instillation of either polyvinyl alcohol, tetracaine, or oxybuprocaine. The level of statistical significance was 0.05. Results Polyvinyl alcohol, tetracaine hydrochloride, and oxybuprocaine hydrochloride had no statistically significant (P > 0.05) effect on any of the biomechanical parameters of the cornea. There was no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) 2 minutes after the eye drops were instilled in either session. Five minutes after the eye drops were instilled, polyvinyl alcohol showed no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) in

  16. Corneal biomechanical parameters and intraocular pressure: the effect of topical anesthesia.

    PubMed

    Ogbuehi, Kelechi C

    2012-01-01

    The intraocular pressures and biomechanical parameters measured by the ocular response analyzer make the analyzer a useful tool for the diagnosis and management of anterior segment disease. This observational study was designed to investigate the effect of topical anesthesia on the parameters measured by the ocular response analyzer: corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc). Two sets of measurements were made for 78 eyes of 39 subjects, approximately 1 week apart. In session 1, each eye of each subject was randomized into one of three groups: polyvinyl alcohol (0.5%), tetracaine hydrochloride (0.5%), or oxybuprocaine hydrochloride (0.4%). In session 2, eyes that were in the polyvinyl alcohol group in session 1 were assigned to the tetracaine group, those in the tetracaine group in session 1 were assigned to oxybuprocaine group, and those in the oxybuprocaine group in session 1 were assigned to the polyvinyl alcohol group. For both sessions, each subject first had his or her central corneal thickness assessed with a specular microscope, followed by measurements of intraocular pressure and corneal biomechanical parameters with the Ocular Response Analyzer. All measurements were repeated for 2 minutes and 5 minutes following the instillation of either polyvinyl alcohol, tetracaine, or oxybuprocaine. The level of statistical significance was 0.05. Polyvinyl alcohol, tetracaine hydrochloride, and oxybuprocaine hydrochloride had no statistically significant (P > 0.05) effect on any of the biomechanical parameters of the cornea. There was no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) 2 minutes after the eye drops were instilled in either session. Five minutes after the eye drops were instilled, polyvinyl alcohol showed no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) in either session

  17. Soreness-related changes in three-dimensional running biomechanics following eccentric knee extensor exercise.

    PubMed

    Paquette, Max R; Peel, Shelby A; Schilling, Brian K; Melcher, Dan A; Bloomer, Richard J

    2017-06-01

    Runners often experience delayed onset muscle soreness (DOMS), especially of the knee extensors, following prolonged running. Sagittal knee joint biomechanics are altered in the presence of knee extensor DOMS but it is unclear how muscle soreness affects lower limb biomechanics in other planes of motion. The purpose of this study was to assess the effects of knee extensor DOMS on three-dimensional (3D) lower limb biomechanics during running. Thirty-three healthy men (25.8 ± 6.8 years; 84.1 ± 9.2 kg; 1.77 ± 0.07 m) completed an isolated eccentric knee extensor damaging protocol to elicit DOMS. Biomechanics of over-ground running at a set speed of 3.35 m s -1 ±5% were measured before eccentric exercise (baseline) and, 24 h and 48 h following exercise in the presence of knee extensor DOMS. Knee flexion ROM was reduced at 48 h (P = 0.01; d = 0.26), and peak knee extensor moment was reduced at 24 h (P = 0.001; d = 0.49) and 48 h (P < 0.001; d = 0.68) compared to baseline. Frontal and transverse plane biomechanics were unaffected by the presence of DOMS (P > 0.05). Peak positive ankle and knee joint powers and, peak negative knee joint power were all reduced from baseline to 24 h and 48 h (P < 0.05). These findings suggest that knee extensor DOMS greatly influences sagittal knee joint angular kinetics and, reduces sagittal power production at the ankle joint. However, knee extensor DOMS does not affect frontal and transverse plane lower limb joint biomechanics during running.

  18. Selecting Sensitive Parameter Subsets in Dynamical Models With Application to Biomechanical System Identification.

    PubMed

    Ramadan, Ahmed; Boss, Connor; Choi, Jongeun; Peter Reeves, N; Cholewicki, Jacek; Popovich, John M; Radcliffe, Clark J

    2018-07-01

    Estimating many parameters of biomechanical systems with limited data may achieve good fit but may also increase 95% confidence intervals in parameter estimates. This results in poor identifiability in the estimation problem. Therefore, we propose a novel method to select sensitive biomechanical model parameters that should be estimated, while fixing the remaining parameters to values obtained from preliminary estimation. Our method relies on identifying the parameters to which the measurement output is most sensitive. The proposed method is based on the Fisher information matrix (FIM). It was compared against the nonlinear least absolute shrinkage and selection operator (LASSO) method to guide modelers on the pros and cons of our FIM method. We present an application identifying a biomechanical parametric model of a head position-tracking task for ten human subjects. Using measured data, our method (1) reduced model complexity by only requiring five out of twelve parameters to be estimated, (2) significantly reduced parameter 95% confidence intervals by up to 89% of the original confidence interval, (3) maintained goodness of fit measured by variance accounted for (VAF) at 82%, (4) reduced computation time, where our FIM method was 164 times faster than the LASSO method, and (5) selected similar sensitive parameters to the LASSO method, where three out of five selected sensitive parameters were shared by FIM and LASSO methods.

  19. Measuring systems of hard to get objects: problems with analysis of measurement results

    NASA Astrophysics Data System (ADS)

    Gilewska, Grazyna

    2005-02-01

    The problem accessibility of metrological parameters features of objects appeared in many measurements. Especially if it is biological object which parameters very often determined on the basis of indirect research. Accidental component predominate in forming of measurement results with very limited access to measurement objects. Every measuring process has a lot of conditions limiting its abilities to any way processing (e.g. increase number of measurement repetition to decrease random limiting error). It may be temporal, financial limitations, or in case of biological object, small volume of sample, influence measuring tool and observers on object, or whether fatigue effects e.g. at patient. It's taken listing difficulties into consideration author worked out and checked practical application of methods outlying observation reduction and next innovative methods of elimination measured data with excess variance to decrease of mean standard deviation of measured data, with limited aomunt of data and accepted level of confidence. Elaborated methods wee verified on the basis of measurement results of knee-joint width space got from radiographs. Measurements were carried out by indirectly method on the digital images of radiographs. Results of examination confirmed legitimacy to using of elaborated methodology and measurement procedures. Such methodology has special importance when standard scientific ways didn't bring expectations effects.

  20. Biomechanical and psychosocial work exposures and musculoskeletal symptoms among vineyard workers.

    PubMed

    Bernard, Christophe; Courouve, Laurène; Bouée, Stéphane; Adjémian, Annie; Chrétien, Jean-Claude; Niedhammer, Isabelle

    2011-01-01

    This study explored the associations between biomechanical and psychosocial work factors and musculoskeletal symptoms in vineyard workers. This cross-sectional study was based on a random sample of 2,824 male and 1,123 female vineyard workers in France. Data were collected using a self-administered questionnaire. Neck/shoulder, back and upper and lower extremity symptoms were evaluated using the Nordic questionnaire. Biomechanical exposures included 15 tasks related to vineyard activities. Psychosocial work factors included effort-reward imbalance and overcommitment, measured using the effort-reward imbalance model, and low job control and insufficient material means. Statistical analysis was performed using logistic regression analysis, and the results were adjusted for age, body mass index, educational level, work status and years in vineyard. Pruning-related factors increased the risk of upper extremity pain for both genders, of back pain for men and of neck/shoulder and lower extremity pain for women. Driving increased the risk of neck/shoulder and back pain among men. Psychosocial work factors, which were insufficient material means, overcommitment (both genders), effort-reward imbalance (men) and low job control (women), were associated with musculoskeletal symptoms, back and upper extremity pain for both genders and neck/shoulder and lower extremity pain for men. These results underlined that both biomechanical and psychosocial work factors may play a role in musculoskeletal pain among vineyard workers. Prevention policies focusing on both biomechanical and psychosocial work exposures may be useful to prevent musculoskeletal symptoms.

  1. The application of 3D-printed transparent facemask for facial scar management and its biomechanical rationale.

    PubMed

    Wei, Yating; Wang, Yan; Zhang, Ming; Yan, Gang; Wu, Shixue; Liu, Wenjun; Ji, Gang; Li-Tsang, Cecilia W P

    2018-03-01

    Deep facial burns leave conspicuous scar to the patients and affect their quality of life. Transparent facemask has been adopted for the prevention and treatment of facial hypertrophic scars for decades. Recently, with the advancement of 3D printing, the transparent facemask could facilitate the fitting of the facial contour. However, the effectiveness of the device and its biomechanical characteristics on pressure management of hypertrophic scar would need more objective evaluation. A biomechanical model of the transparent 3D-printed facemask was established through finite element analysis. Ten patients with extensive deep facial burns within 6 months were recruited for clinical study using 3D-printed facemask designed according to biomechanical model, and the interface pressure was measured on each patient. The patients in the treatment group (n=5) was provided with the 3D-printed transparent face mask soon after initial scar assessment, while the delayed treatment group (n=5) began the treatment one month after the initial scar assessment. The scar assessment was performed one month post intervention for both groups. The biomechanical modeling showed that the 3D, computer-generated facemask resulted in unbalanced pressure if design modifications were not incorporated to address these issues. The interface pressure between the facemask and patient's face was optimized through individualized design adjustments and the addition of silicone lining. After optimization of pressure through additional lining, the mean thickness and hardness of the scars of all 10 patients were decreased significantly after 1-month of intervention. In the delayed treatment group, the mean thickness of the scars was increased within the month without intervention, but it was also decreased after intervention. Facemask design and the silicone lining are important to ensure adequate compression pressure of 3D-printed transparent facemask. The intervention using the 3D-printed facemask

  2. A rapid prototyping model for biomechanical evaluation of pelvic osteotomies.

    PubMed

    Pressel, Thomas; Max, Stefan; Pfeifer, Roman; Ostermeier, Sven; Windhagen, Henning; Hurschler, Christof

    2008-04-01

    The biomechanical consequences of Salter pelvic osteotomy are difficult to assess due to the complex three-dimensional anatomy of the pelvis. Therefore, models of the dysplastic pelvis are required to allow realistic biomechanical simulation of possible outcomes. A polyamide reversed-engineering model of the left hemipelvis and proximal femur was produced from a computed tomography dataset of an 8-year-old child with severe dysplasia of both hips using selective laser sintering. Hip joint forces before and after Salter osteotomy of the hip were measured using an experimental setup in which an industrial robot was exerting hip joint forces and moments representing one-legged stance. Hip extensor and abductor actuator forces were measured which counterbalanced the joint moments. The preoperative hip joint resultant force was 583 N (270% body weight), while after the operation a mean force of 266 N (120% body weight) was measured. The resulting bony model was geometrically accurate, while apparent joint incongruencies were due to the neglected cartilaginous structures in the model. The preoperative joint resultant force was within the limits reported in the literature. The results suggest that Salter innominate osteotomy not only increases joint contact area but also reduces the hip joint force.

  3. Unified Approach to the Biomechanics of Dental Implantology

    NASA Technical Reports Server (NTRS)

    Grenoble, D. E.; Knoell, A. C.

    1973-01-01

    The human need for safe and effective dental implants is well-recognized. Although many implant designs have been tested and are in use today, a large number have resulted in clinical failure. These failures appear to be due to biomechanical effects, as well as biocompatibility and surgical factors. A unified approach is proposed using multidisciplinary systems technology, for the study of the biomechanical interactions between dental implants and host tissues. The approach progresses from biomechanical modeling and analysis, supported by experimental investigations, through implant design development, clinical verification, and education of the dental practitioner. The result of the biomechanical modeling, analysis, and experimental phases would be the development of scientific design criteria for implants. Implant designs meeting these criteria would be generated, fabricated, and tested in animals. After design acceptance, these implants would be tested in humans, using efficient and safe surgical and restorative procedures. Finally, educational media and instructional courses would be developed for training dental practitioners in the use of the resulting implants.

  4. MR Morphology of Triangular Fibrocartilage Complex: Correlation with Quantitative MR and Biomechanical Properties

    PubMed Central

    Bae, Won C.; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda

    2016-01-01

    Objective To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Materials and Methods Five cadaveric wrists (22 to 70 yrs) were imaged at 3T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. Results On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. Conclusion These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. PMID:26691643

  5. The effect of pharmacological treatment on gait biomechanics in peripheral arterial disease patients

    PubMed Central

    2010-01-01

    Background Pharmacological treatment has been advocated as a first line therapy for Peripheral Arterial Disease (PAD) patients suffering from intermittent claudication. Previous studies document the ability of pharmacological treatment to increase walking distances. However, the effect of pharmacological treatment on gait biomechanics in PAD patients has not been objectively evaluated as is common with other gait abnormalities. Methods Sixteen patients were prescribed an FDA approved drug (Pentoxifylline or Cilostazol) for the treatment of symptomatic PAD. Patients underwent baseline gait testing prior to medication use which consisted of acquisition of ground reaction forces and kinematics while walking in a pain free state. After three months of treatment, patients underwent repeat gait testing. Results Patients with symptomatic PAD had significant gait abnormalities at baseline during pain free walking as compared to healthy controls. However, pharmacological treatment did not produce any identifiable alterations on the biomechanics of gait of the PAD patients as revealed by the statistical comparisons performed between pre and post-treatment and between post-treatment and the healthy controls. Conclusions Pharmacological treatment did not result in statistically significant improvements in the gait biomechanics of patients with symptomatic PAD. Future studies will need to further explore different cohorts of patients that have shown to improve significantly their claudication distances and/or their muscle fiber morphology with the use of pharmacological treatment and determine if this is associated with an improvement in gait biomechanics. Using these methods we may distinguish the patients who benefit from pharmacotherapy and those who do not. PMID:20529284

  6. Selected questions on biomechanical exposures for surveillance of upper-limb work-related musculoskeletal disorders

    PubMed Central

    Descatha, Alexis; Roquelaure, Yves; Evanoff, Bradley; Niedhammer, Isabelle; Chastang, Jean François; Mariot, Camille; Ha, Catherine; Imbernon, Ellen; Goldberg, Marcel; Leclerc, Annette

    2007-01-01

    Objective Questionnaires for assessment of biomechanical exposure are frequently used in surveillance programs, though few studies have evaluated which key questions are needed. We sought to reduce the number of variables on a surveillance questionnaire by identifying which variables best summarized biomechanical exposure in a survey of the French working population. Methods We used data from the 2002–2003 French experimental network of Upper-limb work-related musculoskeletal disorders (UWMSD), performed on 2685 subjects in which 37 variables assessing biomechanical exposures were available (divided into four ordinal categories, according to the task frequency or duration). Principal Component Analysis (PCA) with orthogonal rotation was performed on these variables. Variables closely associated with factors issued from PCA were retained, except those highly correlated to another variable (rho>0.70). In order to study the relevance of the final list of variables, correlations between a score based on retained variables (PCA score) and the exposure score suggested by the SALTSA group were calculated. The associations between the PCA score and the prevalence of UWMSD were also studied. In a final step, we added back to the list a few variables not retained by PCA, because of their established recognition as risk factors. Results According to the results of the PCA, seven interpretable factors were identified: posture exposures, repetitiveness, handling of heavy loads, distal biomechanical exposures, computer use, forklift operator specific task, and recovery time. Twenty variables strongly correlated with the factors obtained from PCA were retained. The PCA score was strongly correlated both with the SALTSA score and with UWMSD prevalence (p<0.0001). In the final step, six variables were reintegrated. Conclusion Twenty-six variables out of 37 were efficiently selected according to their ability to summarize major biomechanical constraints in a working population

  7. Effects of Taping and Orthoses on Foot Biomechanics in Adults with Flat-Arched Feet.

    PubMed

    Bishop, Christopher; Arnold, John B; May, Thomas

    2016-04-01

    There is a paucity of evidence on the biomechanical effects of foot taping and foot orthoses in realistic conditions. This study aimed to determine the immediate effect and relationships between changes in multisegment foot biomechanics with foot taping and customized foot orthoses in adults with flat-arched feet. Multisegment foot biomechanics were measured in 18 adults with flat-arched feet (age 25.1 ± 2.8 yr; height 1.73 ± .13 m, body mass 70.3 ± 15.7 kg) during walking in four conditions in random order: neutral athletic shoe, neutral shoe with tape (low-Dye method and modified method) and neutral shoe with customized foot orthoses. In-shoe foot biomechanics were compared between conditions using a purpose developed foot model with three-dimensional kinematic analysis and inverse dynamics. Foot orthoses significantly delayed peak eversion compared to the neutral shoe (44% stance vs 39%, P = 0.002). Deformation across the midfoot and medial longitudinal arch was reduced with both the low-Dye taping (2.4°, P < 0.001) and modified taping technique (5.5°, P < 0.001). All interventions increased peak dorsiflexion of the first metatarsophalangeal joint (1.4°-3.2°, P < 0.001-0.023). Biomechanical responses to taping significantly predicted corresponding changes to foot orthoses (R2 = 0.08-0.52, P = 0.006 to <0.001). Foot orthoses more effectively altered timing of hindfoot motion whereas taping was superior in supporting the midfoot and medial longitudinal arch. The biomechanical response to taping was significantly related to the subsequent change observed with the use of foot orthoses.

  8. An Improved Suite of Object Oriented Software Measures

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.; Weistroffer, H. Roland; Coppins, Richard J.

    1997-01-01

    In the pursuit of ever increasing productivity, the need to be able to measure specific aspects of software is generally agreed upon. As object oriented programming languages are becoming more and more widely used, metrics specifically designed for object oriented software are required. In recent years there has been an explosion of new, object oriented software metrics proposed in the literature. Unfortunately, many or most of these proposed metrics have not been validated to measure what they claim to measure. In fact, an analysis of many of these metrics shows that they do not satisfy basic properties of measurement theory, and thus their application has to be suspect. In this paper ten improved metrics are proposed and are validated using measurement theory.

  9. Validation of Computational Models in Biomechanics

    PubMed Central

    Henninger, Heath B.; Reese, Shawn P.; Anderson, Andrew E.; Weiss, Jeffrey A.

    2010-01-01

    The topics of verification and validation (V&V) have increasingly been discussed in the field of computational biomechanics, and many recent articles have applied these concepts in an attempt to build credibility for models of complex biological systems. V&V are evolving techniques that, if used improperly, can lead to false conclusions about a system under study. In basic science these erroneous conclusions may lead to failure of a subsequent hypothesis, but they can have more profound effects if the model is designed to predict patient outcomes. While several authors have reviewed V&V as they pertain to traditional solid and fluid mechanics, it is the intent of this manuscript to present them in the context of computational biomechanics. Specifically, the task of model validation will be discussed with a focus on current techniques. It is hoped that this review will encourage investigators to engage and adopt the V&V process in an effort to increase peer acceptance of computational biomechanics models. PMID:20839648

  10. Hand rim wheelchair propulsion training using biomechanical real-time visual feedback based on motor learning theory principles.

    PubMed

    Rice, Ian; Gagnon, Dany; Gallagher, Jere; Boninger, Michael

    2010-01-01

    As considerable progress has been made in laboratory-based assessment of manual wheelchair propulsion biomechanics, the necessity to translate this knowledge into new clinical tools and treatment programs becomes imperative. The objective of this study was to describe the development of a manual wheelchair propulsion training program aimed to promote the development of an efficient propulsion technique among long-term manual wheelchair users. Motor learning theory principles were applied to the design of biomechanical feedback-based learning software, which allows for random discontinuous real-time visual presentation of key spatiotemporal and kinetic parameters. This software was used to train a long-term wheelchair user on a dynamometer during 3 low-intensity wheelchair propulsion training sessions over a 3-week period. Biomechanical measures were recorded with a SmartWheel during over ground propulsion on a 50-m level tile surface at baseline and 3 months after baseline. Training software was refined and administered to a participant who was able to improve his propulsion technique by increasing contact angle while simultaneously reducing stroke cadence, mean resultant force, peak and mean moment out of plane, and peak rate of rise of force applied to the pushrim after training. The proposed propulsion training protocol may lead to favorable changes in manual wheelchair propulsion technique. These changes could limit or prevent upper limb injuries among manual wheelchair users. In addition, many of the motor learning theory-based techniques examined in this study could be applied to training individuals in various stages of rehabilitation to optimize propulsion early on.

  11. Ecological biomechanics of benthic organisms: life history, mechanical design and temporal patterns of mechanical stress.

    PubMed

    Koehl, M A

    1999-12-01

    We can gain biomechanical insights if we couple knowledge of the environments, ecological roles and life history strategies of organisms with our laboratory analyses of their mechanical function or fluid dynamics, as illustrated by studies of the mechanical design of bottom-dwelling marine organisms. Obviously, measurements of the spatial and temporal distribution of loads on an organism in nature reveal the magnitudes and rates at which biomechanical tests should be performed in the laboratory. Furthermore, knowledge of the population biology and ecological interactions of the organisms being studied is crucial to determine when during the life of an individual particular aspects of mechanical performance should be measured; not only can the size, shape and material properties of an individual change during ontogeny, but so can its habitat, activities and ecological role. Such ecological information is also necessary to determine whether the aspects of mechanical performance being studied are biologically important, i.e. whether they affect the survivorship or fitness of the organisms. My point in raising these examples is to illustrate how ecological studies can enhance or change our understanding of biomechanical function.

  12. Biomechanical forces promote embryonic haematopoiesis

    PubMed Central

    Adamo, Luigi; Naveiras, Olaia; Wenzel, Pamela L.; McKinney-Freeman, Shannon; Mack, Peter J.; Gracia-Sancho, Jorge; Suchy-Dicey, Astrid; Yoshimoto, Momoko; Lensch, M. William; Yoder, Mervin C.; García-Cardeña, Guillermo; Daley, George Q.

    2009-01-01

    Biomechanical forces are emerging as critical regulators of embryogenesis, particularly in the developing cardiovascular system1,2. After initiation of the heartbeat in vertebrates, cells lining the ventral aspect of the dorsal aorta, the placental vessels, and the umbilical and vitelline arteries initiate expression of the transcription factor Runx1 (refs 3–5), a master regulator of haematopoiesis, and give rise to haematopoietic cells4. It remains unknown whether the biomechanical forces imposed on the vascular wall at this developmental stage act as a determinant of haematopoietic potential6. Here, using mouse embryonic stem cells differentiated in vitro, we show that fluid shear stress increases the expression of Runx1 in CD41+c-Kit+ haematopoietic progenitor cells7,concomitantly augmenting their haematopoietic colony-forming potential. Moreover, we find that shear stress increases haematopoietic colony-forming potential and expression of haematopoietic markers in the paraaortic splanchnopleura/aorta–gonads–mesonephros of mouse embryos and that abrogation of nitric oxide, a mediator of shear-stress-induced signalling8, compromises haematopoietic potential in vitro and in vivo. Collectively, these data reveal a critical role for biomechanical forces in haematopoietic development. PMID:19440194

  13. Physiological, biomechanical and anthropometrical predictors of sprint swimming performance in adolescent swimmers.

    PubMed

    Lätt, Evelin; Jürimäe, Jaak; Mäestu, Jarek; Purge, Priit; Rämson, Raul; Haljaste, Kaja; Keskinen, Kari L; Rodriguez, Ferran A; Jürimäe, Toivo

    2010-01-01

    The purpose of this study was to analyze the relationships between 100-m front crawl swimming performance and relevant biomechanical, anthropometrical and physiological parameters in male adolescent swimmers. Twenty five male swimmers (mean ± SD: age 15. 2 ± 1.9 years; height 1.76 ± 0.09 m; body mass 63.3 ± 10.9 kg) performed an all-out 100-m front crawl swimming test in a 25-m pool. A respiratory snorkel and valve system with low hydrodynamic resistance was used to collect expired air. Oxygen uptake was measured breath-by-breath by a portable metabolic cart. Swimming velocity, stroke rate (SR), stroke length and stroke index (SI) were assessed during the test by time video analysis. Blood samples for lactate measurement were taken from the fingertip pre exercise and at the third and fifth minute of recovery to estimate net blood lactate accumulation (ΔLa). The energy cost of swimming was estimated from oxygen uptake and blood lactate energy equivalent values. Basic anthropometry included body height, body mass and arm span. Body composition parameters were measured using dual-energy X-ray absorptiometry (DXA). Results indicate that biomechanical factors (90.3%) explained most of 100-m front crawl swimming performance variability in these adolescent male swimmers, followed by anthropometrical (45.8%) and physiological (45.2%) parameters. SI was the best single predictor of performance, while arm span and ∆La were the best anthropometrical and physiological indicators, respectively. SI and SR alone explained 92.6% of the variance in competitive performance. These results confirm the importance of considering specific stroke technical parameters when predicting success in young swimmers. Key pointsThis study investigated the influence of different anthropometrical, physiological and biomechanical parameters on 100-m swimming performance in adolescent boys.Biomechanical factors contributed most to sprint swimming performance in these young male swimmers (90

  14. Biomechanical Analysis of Treadmill Locomotion on the International Space Station

    NASA Technical Reports Server (NTRS)

    De Witt, J. K.; Fincke, R. S.; Guilliams, M. E.; Ploutz-Snyder, L. L.

    2011-01-01

    Treadmill locomotion exercise is an important aspect of ISS exercise countermeasures. It is widely believed that an optimized treadmill exercise protocol could offer benefits to cardiovascular and bone health. If training heart rate is high enough, treadmill exercise is expected to lead to improvements in aerobic fitness. If impact or bone loading forces are high enough, treadmill exercise may be expected to contribute to improved bone outcomes. Ground-based research suggests that joint loads increase with increased running speed. However, it is unknown if increases in locomotion speed results in similar increases in joint loads in microgravity. Although data exist regarding the biomechanics of running and walking in microgravity, a majority were collected during parabolic flight or during investigations utilizing a microgravity analog. The Second Generation Treadmill (T2) has been in use on the International Space Station (ISS) and records the ground reaction forces (GRF) produced by crewmembers during exercise. Biomechanical analyses will aid in understanding potential differences in typical gait motion and allow for modeling of the human body to determine joint and muscle forces during exercise. By understanding these mechanisms, more appropriate exercise prescriptions can be developed that address deficiencies. The objective of this evaluation is to collect biomechanical data from crewmembers during treadmill exercise prior to and during flight. The goal is to determine if locomotive biomechanics differ between normal and microgravity environments and to determine how combinations of subject load and speed influence joint loading during in-flight treadmill exercise. Further, the data will be used to characterize any differences in specific bone and muscle loading during locomotion in these two gravitational conditions. This project maps to the HRP Integrated Research Plan risks including Risk of Bone Fracture (Gap B15), Risk of Early Onset Osteoporosis Due to

  15. Scleral Biomechanics in the Aging Monkey Eye

    PubMed Central

    Girard, Michaël J. A.; Suh, J-K. Francis; Bottlang, Michael; Burgoyne, Claude F.; Downs, J. Crawford

    2010-01-01

    Purpose To investigate the age-related differences in the inhomogeneous, anisotropic, nonlinear biomechanical properties of posterior sclera from old (22.9 ± 5.3 years) and young (1.5 ± 0.7 years) rhesus monkeys. Methods The posterior scleral shell of each eye was mounted on a custom-built pressurization apparatus, then intraocular pressure (IOP) was elevated from 5 to 45 mmHg while the 3D displacements of the scleral surface were measured using speckle interferometry. Each scleral shell geometry was digitally reconstructed from data generated by a 3D digitizer (topography) and 20 MHz ultrasounds (thickness). An inverse finite element (FE) method incorporating a fiber-reinforced constitutive model was used to extract a unique set of biomechanical properties for each eye. Displacements, thickness, stress, strain, tangent modulus, structural stiffness, and preferred collagen fiber orientation were mapped for each posterior sclera. Results The model yielded 3-D deformations of posterior sclera that matched well with those observed experimentally. The posterior sclera exhibited inhomogeneous, anisotropic, nonlinear mechanical behavior. The sclera was significantly thinner (p = 0.038), and tangent modulus and structural stiffness were significantly higher in old monkeys (p < 0.0001). On average, scleral collagen fibers were circumferentially oriented around the optic nerve head (ONH). We found no difference in the preferred collagen fiber orientation and fiber concentration factor between age groups. Conclusions Posterior sclera from old monkeys is significantly stiffer than that from young monkeys and is therefore subject to higher stresses but lower strains at all levels of IOP. Age-related stiffening of the sclera may significantly influence ONH biomechanics, and potentially contribute to age-related susceptibility to glaucomatous vision loss. PMID:19494203

  16. Neuromuscular training improves performance and lower-extremity biomechanics in female athletes.

    PubMed

    Myer, Gregory D; Ford, Kevin R; Palumbo, Joseph P; Hewett, Timothy E

    2005-02-01

    The purpose of this study was to examine the effects of a comprehensive neuromuscular training program on measures of performance and lower-extremity movement biomechanics in female athletes. The hypothesis was that significant improvements in measures of performance would be demonstrated concomitant with improved biomechanical measures related to anterior cruciate ligament injury risk. Forty-one female basketball, soccer, and volleyball players (age, 15.3 +/- 0.9 years; weight, 64.8 +/- 9.96 kg; height, 171.2 +/- 7.21 cm) underwent 6 weeks of training that included 4 main components (plyometric and movement, core strengthening and balance, resistance training, and speed training). Twelve age-, height-, and weight-matched controls underwent the same testing protocol twice 6 weeks apart. Trained athletes demonstrated increased predicted 1 repetition maximum squat (92%) and bench press (20%). Right and left single-leg hop distance increased 10.39 cm and 8.53 cm, respectively, and vertical jump also increased from 39.9 +/- 0.9 cm to 43.2 +/- 1.1 cm with training. Speed in a 9.1-m sprint improved from 1.80 +/- 0.02 seconds to 1.73 +/- 0.01 seconds. Pre- and posttest 3-dimensional motion analysis demonstrated increased knee flexion-extension range of motion during the landing phase of a vertical jump (right, 71.9 +/- 1.4 degrees to 76.9 +/- 1.4 degrees ; left, 71.3 +/- 1.5 degrees to 77.3 +/- 1.4 degrees ). Training decreased knee valgus (28%) and varus (38%) torques. Control subjects did not demonstrate significant alterations during the 6-week interval. The results of this study support the hypothesis that the combination of multiple-injury prevention-training components into a comprehensive program improves measures of performance and movement biomechanics.

  17. Biomechanics Simulations Using Cubic Hermite Meshes with Extraordinary Nodes for Isogeometric Cardiac Modeling

    PubMed Central

    Gonzales, Matthew J.; Sturgeon, Gregory; Segars, W. Paul; McCulloch, Andrew D.

    2016-01-01

    Cubic Hermite hexahedral finite element meshes have some well-known advantages over linear tetrahedral finite element meshes in biomechanical and anatomic modeling using isogeometric analysis. These include faster convergence rates as well as the ability to easily model rule-based anatomic features such as cardiac fiber directions. However, it is not possible to create closed complex objects with only regular nodes; these objects require the presence of extraordinary nodes (nodes with 3 or >= 5 adjacent elements in 2D) in the mesh. The presence of extraordinary nodes requires new constraints on the derivatives of adjacent elements to maintain continuity. We have developed a new method that uses an ensemble coordinate frame at the nodes and a local-to-global mapping to maintain continuity. In this paper, we make use of this mapping to create cubic Hermite models of the human ventricles and a four-chamber heart. We also extend the methods to the finite element equations to perform biomechanics simulations using these meshes. The new methods are validated using simple test models and applied to anatomically accurate ventricular meshes with valve annuli to simulate complete cardiac cycle simulations. PMID:27182096

  18. Biomechanics of plant-insect interactions.

    PubMed

    Whitney, Heather M; Federle, Walter

    2013-02-01

    Plant-insect interactions are determined by both chemical and physical mechanisms. Biomechanical factors play an important role across many ecological situations, including pollination, herbivory and plant carnivory, and have led to complex adaptations in both plants and insects. However, while mechanical factors involved in some highly specific interactions have been elucidated, more generalised effects may be widespread but are more difficult to isolate, due to the multifunctional properties of the plant surfaces and tissues where interactions occur. Novel methodologies are being developed to investigate the mechanisms of biomechanical interactions and discover to what extent adaptive structures could be exploited via biomimetics. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Biomechanics of Early Cardiac Development

    PubMed Central

    Goenezen, Sevan; Rennie, Monique Y.

    2012-01-01

    Biomechanics affect early cardiac development, from looping to the development of chambers and valves. Hemodynamic forces are essential for proper cardiac development, and their disruption leads to congenital heart defects. A wealth of information already exists on early cardiac adaptations to hemodynamic loading, and new technologies, including high resolution imaging modalities and computational modeling, are enabling a more thorough understanding of relationships between hemodynamics and cardiac development. Imaging and modeling approaches, used in combination with biological data on cell behavior and adaptation, are paving the road for new discoveries on links between biomechanics and biology and their effect on cardiac development and fetal programming. PMID:22760547

  20. Artificial Intelligence in Sports Biomechanics: New Dawn or False Hope?

    PubMed Central

    Bartlett, Roger

    2006-01-01

    This article reviews developments in the use of Artificial Intelligence (AI) in sports biomechanics over the last decade. It outlines possible uses of Expert Systems as diagnostic tools for evaluating faults in sports movements (‘techniques’) and presents some example knowledge rules for such an expert system. It then compares the analysis of sports techniques, in which Expert Systems have found little place to date, with gait analysis, in which they are routinely used. Consideration is then given to the use of Artificial Neural Networks (ANNs) in sports biomechanics, focusing on Kohonen self-organizing maps, which have been the most widely used in technique analysis, and multi-layer networks, which have been far more widely used in biomechanics in general. Examples of the use of ANNs in sports biomechanics are presented for javelin and discus throwing, shot putting and football kicking. I also present an example of the use of Evolutionary Computation in movement optimization in the soccer throw in, which predicted an optimal technique close to that in the coaching literature. After briefly overviewing the use of AI in both sports science and biomechanics in general, the article concludes with some speculations about future uses of AI in sports biomechanics. Key Points Expert Systems remain almost unused in sports biomechanics, unlike in the similar discipline of gait analysis. Artificial Neural Networks, particularly Kohonen Maps, have been used, although their full value remains unclear. Other AI applications, including Evolutionary Computation, have received little attention. PMID:24357939

  1. Artificial intelligence in sports biomechanics: new dawn or false hope?

    PubMed

    Bartlett, Roger

    2006-12-15

    This article reviews developments in the use of Artificial Intelligence (AI) in sports biomechanics over the last decade. It outlines possible uses of Expert Systems as diagnostic tools for evaluating faults in sports movements ('techniques') and presents some example knowledge rules for such an expert system. It then compares the analysis of sports techniques, in which Expert Systems have found little place to date, with gait analysis, in which they are routinely used. Consideration is then given to the use of Artificial Neural Networks (ANNs) in sports biomechanics, focusing on Kohonen self-organizing maps, which have been the most widely used in technique analysis, and multi-layer networks, which have been far more widely used in biomechanics in general. Examples of the use of ANNs in sports biomechanics are presented for javelin and discus throwing, shot putting and football kicking. I also present an example of the use of Evolutionary Computation in movement optimization in the soccer throw in, which predicted an optimal technique close to that in the coaching literature. After briefly overviewing the use of AI in both sports science and biomechanics in general, the article concludes with some speculations about future uses of AI in sports biomechanics. Key PointsExpert Systems remain almost unused in sports biomechanics, unlike in the similar discipline of gait analysis.Artificial Neural Networks, particularly Kohonen Maps, have been used, although their full value remains unclear.Other AI applications, including Evolutionary Computation, have received little attention.

  2. Masticatory biomechanics in the rabbit: a multi-body dynamics analysis.

    PubMed

    Watson, Peter J; Gröning, Flora; Curtis, Neil; Fitton, Laura C; Herrel, Anthony; McCormack, Steven W; Fagan, Michael J

    2014-10-06

    Multi-body dynamics is a powerful engineering tool which is becoming increasingly popular for the simulation and analysis of skull biomechanics. This paper presents the first application of multi-body dynamics to analyse the biomechanics of the rabbit skull. A model has been constructed through the combination of manual dissection and three-dimensional imaging techniques (magnetic resonance imaging and micro-computed tomography). Individual muscles are represented with multiple layers, thus more accurately modelling muscle fibres with complex lines of action. Model validity was sought through comparing experimentally measured maximum incisor bite forces with those predicted by the model. Simulations of molar biting highlighted the ability of the masticatory system to alter recruitment of two muscle groups, in order to generate shearing or crushing movements. Molar shearing is capable of processing a food bolus in all three orthogonal directions, whereas molar crushing and incisor biting are predominately directed vertically. Simulations also show that the masticatory system is adapted to process foods through several cycles with low muscle activations, presumably in order to prevent rapidly fatiguing fast fibres during repeated chewing cycles. Our study demonstrates the usefulness of a validated multi-body dynamics model for investigating feeding biomechanics in the rabbit, and shows the potential for complementing and eventually reducing in vivo experiments.

  3. Masticatory biomechanics in the rabbit: a multi-body dynamics analysis

    PubMed Central

    Watson, Peter J.; Gröning, Flora; Curtis, Neil; Fitton, Laura C.; Herrel, Anthony; McCormack, Steven W.; Fagan, Michael J.

    2014-01-01

    Multi-body dynamics is a powerful engineering tool which is becoming increasingly popular for the simulation and analysis of skull biomechanics. This paper presents the first application of multi-body dynamics to analyse the biomechanics of the rabbit skull. A model has been constructed through the combination of manual dissection and three-dimensional imaging techniques (magnetic resonance imaging and micro-computed tomography). Individual muscles are represented with multiple layers, thus more accurately modelling muscle fibres with complex lines of action. Model validity was sought through comparing experimentally measured maximum incisor bite forces with those predicted by the model. Simulations of molar biting highlighted the ability of the masticatory system to alter recruitment of two muscle groups, in order to generate shearing or crushing movements. Molar shearing is capable of processing a food bolus in all three orthogonal directions, whereas molar crushing and incisor biting are predominately directed vertically. Simulations also show that the masticatory system is adapted to process foods through several cycles with low muscle activations, presumably in order to prevent rapidly fatiguing fast fibres during repeated chewing cycles. Our study demonstrates the usefulness of a validated multi-body dynamics model for investigating feeding biomechanics in the rabbit, and shows the potential for complementing and eventually reducing in vivo experiments. PMID:25121650

  4. Biomechanics of the thorax – research evidence and clinical expertise

    PubMed Central

    Lee, Diane Gail

    2015-01-01

    Understanding the biomechanics of the thorax is critical for understanding its role in multiple conditions since the thorax is part of many integrated systems including the musculoskeletal, respiratory, cardiac, digestive and urogynecological. The thorax is also an integrated system within itself and an element of the whole body/person. Therefore, understanding the biomechanics of the thorax is fundamental to all forms of treatment for multiple conditions. The interpretation of movement examination findings depends on one's view of optimal biomechanics and the influential factors. This article will provide a synopsis of the current state of research evidence as well as observations from clinical experience pertaining to the biomechanics of the thorax in order to help clinicians organise this knowledge and facilitate evidence-based and informed management of the, often complex, patient with or without thoracic pain and impairment. The integrated systems model (ISM) will be introduced as a way to determine when the noted biomechanical findings are relevant to a patient's clinical presentation. PMID:26309383

  5. Biomechanical analysis of loading/unloading a ladder on a truck.

    PubMed

    Moriguchi, Cristiane Shinohara; Carnaz, Leticia; de Miranda, Luiz Carlos; Marklin, Richard William; Coury, Helenice Jane Cote Gil

    2012-01-01

    Loading/unloading a ladder on vehicles are frequent tasks and involve overhead handling that may expose workers to risk factors of shoulder musculoskeletal disorders. The objective of the present study was to evaluate posture, forces required and perceived exertion when loading and unloading the ladder on a utility truck. Thirteen male overhead line workers from an electric utility in Brazil participated in this study. Shoulder elevation angle was measured using inclinometers. The required force to load/unload the ladder was measured by dynamometer. Subjective assessment of the perceived exertion was recorded to compare the exertion reported during the test conditions to the field conditions. The task of loading/unloading the ladder presented risks of shoulder musculoskeletal disorders (MSDs) to workers because it requires high levels of force (approximately 60% of the maximal force) combined with overhead posture of the shoulders (more than 100° from the neutral posture). Age and height presented to interfere in biomechanical risks presented in load/unload task. There was no significant difference between the subjective exertion during the test conditions and handling the ladder in the field. Ergonomic intervention is recommended to reduce these risks for shoulder MSDs.

  6. Factors Related to Students' Learning of Biomechanics Concepts

    ERIC Educational Resources Information Center

    Hsieh, ChengTu; Smith, Jeremy D.; Bohne, Michael; Knudson, Duane

    2012-01-01

    The purpose of this study was to replicate and expand a previous study to identify the factors that affect students' learning of biomechanical concepts. Students were recruited from three universities (N = 149) located in the central and western regions of the United States. Data from 142 students completing the Biomechanics Concept Inventory…

  7. First ultraviolet reflectance measurements of several Kuiper Belt objects, Kuiper Belt object satellites, and new ultraviolet measurements of A Centaur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stern, S. A.; Schindhelm, E.; Cunningham, N. J., E-mail: astern@swri.edu

    We observed the 2600-3200 Å (hereafter, mid-UV) reflectance of two Kuiper Belt Objects (KBOs), two KBO satellites, and a Centaur, using the Hubble Space Telescope (HST) Cosmic Origins Spectrograph (COS). Other than measurements of the Pluto system, these constitute the first UV measurements obtained of KBOs, and KBO satellites, and new HST UV measurements of the Centaur 2060 Chiron. We find significant differences among these objects, constrain the sizes and densities of Haumea's satellites, and report the detection of a possible spectral absorption band in Haumea's spectrum near 3050 Å. Comparisons of these objects to previously published UV reflectance measurementsmore » of Pluto and Charon are also made here.« less

  8. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis.

    PubMed

    Akça, Kivanç; Chang, Ting-Ling; Tekdemir, Ibrahim; Fanuscu, Mete I

    2006-08-01

    The objective of this biomechanical study was to explore the effect of bone micro-morphology on initial intraosseous stability of implants with different designs. Straumann and Astra Tech dental implants were placed into anterior and posterior regions of completely edentulous maxilla and mandible of a human cadaver. Experiments were undertaken to quantify initial implant stability and bone micro-morphology. Installation torque values (ITVs) and implant stability quotients (ISQs) were measured to determine initial intraosseous implant stability. For quantification of relative bone volume and micro-architecture, sectioned implant-bone and bone core specimens of each implant placement site were consecutively scanned and trabecular bone was analyzed in a micro-computed tomography (micro-CT) unit. Experimental outcomes were evaluated for correlations among implant designs, initial intraosseous implant stability and bone micro-structural parameters. ITVs correlated higher with bone volume fraction (BV/TV) than ISQs, at 88.1% and 68.9% levels, respectively. Correlations between ITVs and micro-morphometric parameters were significant at the 95% confidence level (P<0.05) while ISQs were not. Differences in ITVs, ISQs and BV/TV data in regards to implant designs used were not significant at the 95% confidence level (P>0.05). Bone micro-morphology has a prevailing effect over implant design on intraosseus initial implant stability, and ITV is more sensitive in terms of revealing biomechanical properties at the bone-implant interface in comparison with ISQ.

  9. Hormones Restore Biomechanical Properties of the Vagina and Supportive Tissues After Surgical Menopause in Young Rats

    PubMed Central

    Moalli, Pamela A; Debes, Kristen M.; Meyn, Leslie A.; Howden, Nancy; Abramowitch, Steven D.

    2010-01-01

    Objective To determine the impact of hormones on the biomechanical properties of the vagina and its supportive tissues following surgical menopause in young vs middle aged rats. Methods Long-Evans rats [4-month virgin (N = 34), 4-month parous (N = 36), and 9-month parous (N = 34)], underwent ovariectomy (OVX) or sham surgery. OVX'd animals received hormones [estrogen (E2) or estrogen plus progesterone (E2 + P4)], placebo, or the Matrix Metalloproteinase inhibitor (CMT-8). Animals were sacrificed after 8 weeks and the biomechanical properties of the vagina and supportive tissues determined. Data was analyzed using a one-way analysis of variance and post-hoc tests. Results OVX induced a rapid decline in the biomechanical properties of pelvic tissues in young but not middle aged rats. Supplementation with E2, E2 + P4, or CMT-8 restored tissues of young rats to control levels with no effect on middle aged tissues. Parity did not impact tissue behavior. Conclusions OVX has a differential effect on the tissues of young vs middle aged rats. PMID:18395691

  10. Biomechanics research in ski jumping, 1991-2006.

    PubMed

    Schwameder, Hermann

    2008-01-01

    In this paper, I review biomechanics research in ski jumping with a specific focus on publications presented between 1991 and 2006 on performance enhancement, limiting factors of the take-off, specific training and conditioning, aerodynamics, and safety. The first section presents a brief description of ski jumping phases (in-run, take-off, early flight, stable flight, and landing) regarding the biomechanical and functional fundamentals. The most important and frequently used biomechanical methods in ski jumping (kinematics, ground reaction force analyses, muscle activation patterns, aerodynamics) are summarized in the second section. The third section focuses on ski jumping articles and research findings published after the establishment of the V-technique in 1991, as the introduction of this technique has had a major influence on performance enhancement, ski jumping regulations, and the construction of hill profiles. The final section proposes topics for future research in the biomechanics of ski jumping, including: take-off and early flight and the relative roles of vertical velocity and forward somersaulting angular momentum; optimal jumping patterns utilizing the capabilities of individual athletes; development of kinematic and kinetic feedback systems for hill jumps; comparisons of simulated and hill jumps; effect of equipment modifications on performance and safety enhancement.

  11. Influence of different sizes of composite femora on the biomechanical behavior of cementless hip prosthesis.

    PubMed

    Schmidutz, Florian; Woiczinski, Mathias; Kistler, Manuel; Schröder, Christian; Jansson, Volkmar; Fottner, Andreas

    2017-01-01

    For the biomechanical evaluation of cementless stems different sizes of composite femurs have been used in the literature. However, the impact of different specimen sizes on test results is unknown. To determine the potential effect of femur size the biomechanical properties of a conventional stem (CLS Spotorno) were examined in 3 different sizes (small, medium and large composite Sawbones®). Primary stability was tested under physiologically adapted dynamic loading conditions measuring 3-dimensional micromotions. For the small composite femur the dynamic load needed to be adapted since fractures occurred when reaching 1700N. Additionally, surface strain distribution was recorded before and after implantation to draw conclusions about the tendency for stress shielding. All tested sizes revealed similar micromotions only reaching a significant different level at one measurement point. The highest micromotions were observed at the tip of the stems exceeding the limit for osseous integration of 150μm. Regarding strain distribution the highest strain reduction after implantation was registered in all sizes at the level of the lesser trochanter. Specimen size seems to be a minor influence factor for biomechanical evaluation of cementless stems. However, the small composite femur is less suitable for biomechanical testing since this size failed under physiological adapted loads. For the CLS Spotorno osseous integration is unlikely at the tip of the stem and the tendency for stress shielding is the highest at the level of the lesser trochanter. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Lower Extremity Landing Biomechanics in Both Sexes After a Functional Exercise Protocol

    PubMed Central

    Wesley, Caroline A.; Aronson, Patricia A.; Docherty, Carrie L.

    2015-01-01

    Context Sex differences in landing biomechanics play a role in increased rates of anterior cruciate ligament (ACL) injuries in female athletes. Exercising to various states of fatigue may negatively affect landing mechanics, resulting in a higher injury risk, but research is inconclusive regarding sex differences in response to fatigue. Objective To use the Landing Error Scoring System (LESS), a valid clinical movement-analysis tool, to determine the effects of exercise on the landing biomechanics of males and females. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants Thirty-six (18 men, 18 women) healthy college-aged athletes (members of varsity, club, or intramural teams) with no history of ACL injury or prior participation in an ACL injury-prevention program. Intervention(s) Participants were videotaped performing 3 jump-landing trials before and after performance of a functional, sportlike exercise protocol consisting of repetitive sprinting, jumping, and cutting tasks. Main Outcome Measure(s) Landing technique was evaluated using the LESS. A higher LESS score indicates more errors. The mean of the 3 LESS scores in each condition (pre-exercise and postexercise) was used for statistical analysis. Results Women scored higher on the LESS (6.3 ± 1.9) than men (5.0 ± 2.3) regardless of time (P = .04). Postexercise scores (6.3 ± 2.1) were higher than preexercise scores (5.0 ± 2.1) for both sexes (P = .01), but women were not affected to a greater degree than men (P = .62). Conclusions As evidenced by their higher LESS scores, females demonstrated more errors in landing technique than males, which may contribute to their increased rate of ACL injury. Both sexes displayed poor technique after the exercise protocol, which may indicate that participants experience a higher risk of ACL injury in the presence of fatigue. PMID:26285090

  13. Biomechanical factors influencing the performance of elite Alpine ski racers.

    PubMed

    Hébert-Losier, Kim; Supej, Matej; Holmberg, Hans-Christer

    2014-04-01

    . Investigations on speed skiing (i.e., downhill and super-G) primarily examined the effect of aerodynamic drag on performance, whereas the others examined turn characteristics, energetic principles, technical and tactical skills, and individual traits of high-performing skiers. The range of biomechanical factors reported to influence performance included energy dissipation and conservation, aerodynamic drag and frictional forces, ground reaction force, turn radius, and trajectory of the skis and/or centre of mass. The biomechanical differences between turn techniques, inter-dependency of turns, and abilities of individuals were also identified as influential factors in skiing performance. In the case of slalom and giant slalom events, performance could be enhanced by steering the skis in such a manner to reduce the ski-snow friction and thereby energy dissipated. This was accomplished by earlier initiation of turns, longer path length and trajectory, earlier and smoother application of ground reaction forces, and carving (rather than skidding). During speed skiing, minimizing the exposed frontal area and positioning the arms close to the body were shown to reduce the energy loss due to aerodynamic drag and thereby decrease run times. In actual races, a consistently good performance (i.e., fast time) on different sections of the course, terrains, and snow conditions was a characteristic feature of winners during technical events because these skiers could maximize gains from their individual strengths and minimize losses from their respective weaknesses. Most of the articles reviewed were limited to investigating a relatively small sample size, which is a usual limitation in research on elite athletes. Of further concern was the low number of females studied, representing less than 4% of all the subjects examined in the articles reviewed. In addition, although overall run time is the ultimate measure of performance in alpine ski racing, several other measures of instantaneous

  14. Biomechanical paradigm and interpretation of female pelvic floor conditions before a treatment

    PubMed Central

    Lucente, Vincent; van Raalte, Heather; Murphy, Miles; Egorov, Vladimir

    2017-01-01

    Background Further progress in restoring a woman’s health may be possible if a patient with a damaged pelvic floor could undergo medical imaging and biomechanical diagnostic tests. The results of such tests could contribute to the analysis of multiple treatment options and suggest the optimal one for that patient. Aim To develop a new approach for the biomechanical characterization of vaginal conditions, muscles, and connective tissues in the female pelvic floor. Methods Vaginal tactile imaging (VTI) allows biomechanical assessment of the soft tissue along the entire length of the anterior, posterior, and lateral vaginal walls at rest, with manually applied deflection pressures and with muscle contraction, muscle relaxation, and Valsalva maneuver. VTI allows a large body of measurements to evaluate individual variations in tissue elasticity, support defects, as well as pelvic muscle function. Presuming that 1) the female pelvic floor organs are suspended by ligaments against which muscles contract to open or close the outlets and 2) damaged ligaments weaken the support and may reduce the force of muscle contraction, we made an attempt to characterize multiple pelvic floor structures from VTI data. Results All of the 138 women enrolled in the study were successfully examined with the VTI. The study subjects have had normal pelvic support or pelvic organ prolapse (stages I–IV). The average age of this group of subjects was 60±15 years. We transposed a set of 31 VTI parameters into a quantitative characterization of pelvic muscles and ligamentous structures. Interpretation of the acquired VTI data for normal pelvic floor support and prolapse conditions is proposed based on biomechanical assessment of the functional anatomy. Conclusion Vaginal tactile imaging allows biomechanical characterization of female pelvic floor structures and tissues in vivo, which may help to optimize treatment of the diseased conditions such as prolapse, incontinence, atrophy, and some

  15. The Effect of Dehydration and Fasting on Corneal Biomechanical Properties and Intraocular Pressure.

    PubMed

    Oltulu, Refik; Satirtav, Gunhal; Ersan, Ismail; Soylu, Erkan; Okka, Mehmet; Zengin, Nazmi

    2016-11-01

    To evaluate the changes in corneal biomechanical properties and intraocular pressure (IOP) during fasting period in healthy subjects. Seventy-two eyes of 72 fasting subjects (study group), and 62 eyes of 62 nonfasting subjects (control group) were enrolled in this prospective study undertaken at a single university hospital. All subjects underwent complete ophthalmologic examination including ocular biomechanical evaluation with ocular response analyzer. Ocular response analyzer measurement was performed on the right eyes of the subjects between 5.00 and 6.00 PM after approximately 14 hr of fasting for the study group and after a nonfasting period for the control group. The corneal hysteresis, corneal resistance factor, mean corneal compensated IOP (IOPcc), and Goldmann-correlated IOP (IOPg) values were measured with a patented dynamic bidirectional applanation process. Goldmann-correlated IOP and IOPcc measurements in the study group and the control group were found as 13.8±2.8 mm Hg, 14.6±2.6 mm Hg and 16.3±2.2 mm Hg, 15.7±2.4 mm Hg, respectively. There was statistically significant difference within the two groups in IOPg and IOPcc (P<0.001). In addition, corneal hysteresis and corneal resistance factor significantly decreased in study group compared with control group (P<0.001, P=0.012, respectively). Prolonged fasting causes a significant decrease in IOPg, IOPcc, corneal hysteresis, and corneal resistance factor in healthy subjects, altering the biomechanical properties of the cornea.

  16. Can biomechanical variables predict improvement in crouch gait?

    PubMed Central

    Hicks, Jennifer L.; Delp, Scott L.; Schwartz, Michael H.

    2011-01-01

    Many patients respond positively to treatments for crouch gait, yet surgical outcomes are inconsistent and unpredictable. In this study, we developed a multivariable regression model to determine if biomechanical variables and other subject characteristics measured during a physical exam and gait analysis can predict which subjects with crouch gait will demonstrate improved knee kinematics on a follow-up gait analysis. We formulated the model and tested its performance by retrospectively analyzing 353 limbs of subjects who walked with crouch gait. The regression model was able to predict which subjects would demonstrate ‘improved’ and ‘unimproved’ knee kinematics with over 70% accuracy, and was able to explain approximately 49% of the variance in subjects’ change in knee flexion between gait analyses. We found that improvement in stance phase knee flexion was positively associated with three variables that were drawn from knowledge about the biomechanical contributors to crouch gait: i) adequate hamstrings lengths and velocities, possibly achieved via hamstrings lengthening surgery, ii) normal tibial torsion, possibly achieved via tibial derotation osteotomy, and iii) sufficient muscle strength. PMID:21616666

  17. Development of esMOCA Biomechanic, Motion Capture Instrumentation for Biomechanics Analysis

    NASA Astrophysics Data System (ADS)

    Arendra, A.; Akhmad, S.

    2018-01-01

    This study aims to build motion capture instruments using inertial measurement unit sensors to assist in the analysis of biomechanics. Sensors used are accelerometer and gyroscope. Estimation of orientation sensors is done by digital motion processing in each sensor nodes. There are nine sensor nodes attached to the upper limbs. This sensor is connected to the pc via a wireless sensor network. The development of kinematics and inverse dynamamic models of the upper limb is done in simulink simmechanic. The kinematic model receives streaming data of sensor nodes mounted on the limbs. The output of the kinematic model is the pose of each limbs and visualized on display. The dynamic inverse model outputs the reaction force and reaction moment of each joint based on the limb motion input. Model validation in simulink with mathematical model of mechanical analysis showed results that did not differ significantly

  18. Clinical outcomes and frontal plane two-dimensional biomechanics during the 30-second single leg stance test in patients before and after hip abductor tendon reconstructive surgery.

    PubMed

    Huxtable, Rose E; Ackland, Timothy R; Janes, Gregory C; Ebert, Jay R

    2017-07-01

    Hip abductor tendon tears are a common cause of Greater Trochanteric Pain Syndrome. Conservative treatments are often ineffective and surgical reconstruction may be recommended. This study investigated the improvement in clinical outcomes and frontal plane two-dimensional biomechanics during a 30-second single leg stance test, in patients undergoing reconstruction. We hypothesized that clinical scores and pertinent biomechanical variables would significantly improve post-surgery, and these outcomes would be significantly correlated. Twenty-one patients with symptomatic tendon tears underwent reconstruction. Patients were evaluated pre-surgery, and at 6 and 12months post-surgery, using patient-reported outcome measures, assessment of hip abductor strength and six-minute walk capacity. Frontal plane, two-dimensional, biomechanical variables including pelvis-on-femur angle, pelvic drop, trunk lean and lateral pelvic shift, were evaluated throughout a 30-second single leg stance test. ANOVA evaluated outcomes over time, while Pearson's correlations investigated associations between clinical scores, pain, functional and biomechanical outcome variables. While clinical and functional measures significantly improved (P<0.05) over time, no significant group differences (P>0.05) were observed in biomechanical variables from pre- to post-surgery. While five patients displayed a positive Trendelenburg sign pre-surgery, only one was positive post-surgery. Clinical outcomes and biomechanical variables during the single leg stance test were not correlated. Despite improvements in clinical and functional measures over time, biomechanical changes during a weight bearing single leg stance test were not significantly different following tendon repair. Follow up beyond 12months may be required, whereby symptomatic relief may precede functional and biomechanical improvement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Evaluation of the risk of falling in institution-dwelling elderly: clinical tests versus biomechanical analysis of stepping-up.

    PubMed

    Michel-Pellegrino, Valérie; Hewson, David J; Drieux, Michèle; Duchêne, Jacques

    2007-01-01

    Falls in the elderly constitute a major socio-economic problem for modern healthcare. The aim of the study was to extract biomechanical parameters to indicate balance level and the risk of falling in the elderly. It is a preliminary work as part of the development of a home-test based on force-plate technology. Seven faller and 12 non-faller elderly subjects performed stepped up onto a forceplate. Each subject was tested once per weekday for three weeks. Tinetti, Mini Mental Scale test (MMS) and the Geriatric Depression Scale (GDS) scores were measured before the experimentations. Temporal and ground reaction force parameters were measured. The Tinetti test was not correlated with falls in the following six-month period. In contrast, the biomechanical parameters related to the forces measured at foot-contact and to the durations of the phases of the stepping-up were correlated with fall, as well as with MMS and GDS. These results demonstrated that biomechanical parameters could be used as indicators of balance and risk of fall.

  20. Biomechanical approaches to identify and quantify injury mechanisms and risk factors in women's artistic gymnastics.

    PubMed

    Bradshaw, Elizabeth J; Hume, Patria A

    2012-09-01

    Targeted injury prevention strategies, based on biomechanical analyses, have the potential to help reduce the incidence and severity of gymnastics injuries. This review outlines the potential benefits of biomechanics research to contribute to injury prevention strategies for women's artistic gymnastics by identification of mechanisms of injury and quantification of the effects of injury risk factors. One hundred and twenty-three articles were retained for review after searching electronic databases using key words, including 'gymnastic', 'biomech*', and 'inj*', and delimiting by language and relevance to the paper aim. Impact load can be measured biomechanically by the use of instrumented equipment (e.g. beatboard), instrumentation on the gymnast (accelerometers), or by landings on force plates. We need further information on injury mechanisms and risk factors in gymnastics and practical methods of monitoring training loads. We have not yet shown, beyond a theoretical approach, how biomechanical analysis of gymnastics can help reduce injury risk through injury prevention interventions. Given the high magnitude of impact load, both acute and accumulative, coaches should monitor impact loads per training session, taking into consideration training quality and quantity such as the control of rotation and the height from which the landings are executed.

  1. Planning and the "Measurable Objective."

    ERIC Educational Resources Information Center

    Miller, Ronald H.

    1973-01-01

    Accountability is being required of all America's institutions of higher education. Gallaudet College, an institution for the deaf in Washington, D.C., feels it has found a solution to the accountability problem in the use of "measurable objectives" in its program planning. The first phase from January 1 through June 30, 1972 of…

  2. Biomechanics and Strength of Manual Wheelchair Users

    PubMed Central

    Ambrosio, Fabrisia; Boninger, Michael L; Souza, Aaron L; Fitzgerald, Shirley G; Koontz, Alicia M; Cooper, Rory A

    2005-01-01

    Background/Objective: Previous investigations have identified muscular imbalance in the shoulder as a source of pain and injury in manual wheelchair users. Our aim was to determine whether a correlation exists between strength and pushrim biomechanical variables including: tangential (motive) force (Ft), radial force (Fr), axial force (Fz), total (resultant) force (FR), fraction of effective force (FEF), and cadence. Methods: Peak isokinetic shoulder strength (flexion [FLX], extension [EXT], abduction [ABD], adduction [ADD], internal rotation [IR], and external rotation [ER]) was tested in 22 manual wheelchair users with a BioDex system for 5 repetitions at 60°/s. Subjects then propelled their own manual wheelchair at 2 speeds, 0.9 m/s (2 mph) and 1.8 m/s (4 mph), for 20 seconds, during which kinematic (OPTOTRAK) and kinetic (SMARTWHEEL) data were collected. Peak isokinetic forces in the cardinal planes were correlated with pushrim biomechanical variables. Results: All peak torque strength variables correlated significantly (P ≤ 0.05) with Ft, Fr, and FR, but were not significantly correlated with Fz, FEF, or cadence. Finally, there were no relationships found between muscle strength ratios (for example, FLX/EXT) and Ft, Fr, FR, Fz, or FEF. Conclusion: There was a correlation between strength and force imparted to the pushrim among wheelchair users; however, there was no correlation found in wheelchair propulsion or muscle imbalance. Clinicians should be aware of this, and approach strength training and training in wheelchair propulsion techniques separately. PMID:16869087

  3. Head Impact Biomechanics in Women's College Soccer.

    PubMed

    Lynall, Robert C; Clark, Michael D; Grand, Erin E; Stucker, Jaclyn C; Littleton, Ashley C; Aguilar, Alain J; Petschauer, Meredith A; Teel, Elizabeth F; Mihalik, Jason P

    2016-09-01

    There are limited nonlaboratory soccer head impact biomechanics data. This is surprising given soccer's global popularity. Epidemiological data suggest that female college soccer players are at a greater concussion injury risk than their male counterparts. Therefore, the purposes of our study were to quantify head impact frequency and magnitude during women's soccer practices and games in the National Collegiate Athletic Association and to characterize these data across event type, playing position, year on the team, and segment of game (first and second halves). Head impact biomechanics were collected from female college soccer players (n = 22; mean ± SD age = 19.1 ± 0.1 yr, height = 168.0 ± 3.5 cm, mass = 63.7 ± 6.0 kg). We employed a helmetless head impact measurement device (X2 Biosystems xPatch) before each competition and practice across a single season. Peak linear and rotational accelerations were categorized based on impact magnitude and subsequently analyzed using appropriate nonparametric analyses. Overall, women's college soccer players experience approximately seven impacts per 90 min of game play. The overwhelming majority (~90%) of all head impacts were categorized into our mildest linear acceleration impact classification (10g-20g). Interestingly, a higher percentage of practice impacts in the 20g-40g range compared with games (11% vs 7%) was observed. Head impact biomechanics studies have provided valuable insights into understanding collision sports and for informing evidence-based rule and policy changes. These have included changing the football kickoff, ice hockey body checking ages, and head-to-head hits in both sports. Given soccer's global popularity, and the growing public concern for the potential long-term neurological implications of collision and contact sports, studying soccer has the potential to impact many athletes and the sports medicine professionals caring for them.

  4. Biomechanical measurements of stiffness and strength for five types of whole human and artificial humeri.

    PubMed

    Aziz, Mina S R; Nicayenzi, Bruce; Crookshank, Meghan C; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan

    2014-05-01

    The human humerus is the third largest longbone and experiences 2-3% of all fractures. Yet, almost no data exist on its intact biomechanical properties, thus preventing researchers from obtaining a full understanding of humerus behavior during injury and after being repaired with fracture plates and nails. The aim of this experimental study was to compare the biomechanical stiffness and strength of "gold standard" fresh-frozen humeri to a variety of humerus models. A series of five types of intact whole humeri were obtained: human fresh-frozen (n = 19); human embalmed (n = 18); human dried (n = 15); artificial "normal" (n = 12); and artificial "osteoporotic" (n = 12). Humeri were tested under "real world" clinical loading modes for shear stiffness, torsional stiffness, cantilever bending stiffness, and cantilever bending strength. After removing geometric effects, fresh-frozen results were 585.8 ± 181.5 N/mm2 (normalized shear stiffness); 3.1 ± 1.1 N/(mm2 deg) (normalized torsional stiffness); 850.8 ± 347.9 N/mm2 (normalized cantilever stiffness); and 8.3 ± 2.7 N/mm2 (normalized cantilever strength). Compared to fresh-frozen values, statistical equivalence (p ≥ 0.05) was obtained for all four test modes (embalmed humeri), 1 of 4 test modes (dried humeri), 1 of 4 test modes (artificial "normal" humeri), and 1 of 4 test modes (artificial "osteoporotic" humeri). Age and bone mineral density versus experimental results had Pearson linear correlations ranging from R = -0.57 to 0.80. About 77% of human humeri failed via a transverse or oblique distal shaft fracture, whilst 88% of artificial humeri failed with a mixed transverse + oblique fracture. To date, this is the most comprehensive study on the biomechanics of intact human and artificial humeri and can assist researchers to choose an alternate humerus model that can substitute for fresh-frozen humeri.

  5. Biomechanics of Pediatric Manual Wheelchair Mobility

    PubMed Central

    Slavens, Brooke A.; Schnorenberg, Alyssa J.; Aurit, Christine M.; Tarima, Sergey; Vogel, Lawrence C.; Harris, Gerald F.

    2015-01-01

    Currently, there is limited research of the biomechanics of pediatric manual wheelchair mobility. Specifically, the biomechanics of functional tasks and their relationship to joint pain and health is not well understood. To contribute to this knowledge gap, a quantitative rehabilitation approach was applied for characterizing upper extremity biomechanics of manual wheelchair mobility in children and adolescents during propulsion, starting, and stopping tasks. A Vicon motion analysis system captured movement, while a SmartWheel simultaneously collected three-dimensional forces and moments occurring at the handrim. A custom pediatric inverse dynamics model was used to evaluate three-dimensional upper extremity joint motions, forces, and moments of 14 children with spinal cord injury (SCI) during the functional tasks. Additionally, pain and health-related quality of life outcomes were assessed. This research found that joint demands are significantly different amongst functional tasks, with greatest demands placed on the shoulder during the starting task. Propulsion was significantly different from starting and stopping at all joints. We identified multiple stroke patterns used by the children, some of which are not standard in adults. One subject reported average daily pain, which was minimal. Lower than normal physical health and higher than normal mental health was found in this population. It can be concluded that functional tasks should be considered in addition to propulsion for rehabilitation and SCI treatment planning. This research provides wheelchair users and clinicians with a comprehensive, biomechanical, mobility assessment approach for wheelchair prescription, training, and long-term care of children with SCI. PMID:26442251

  6. Biomechanics of Pediatric Manual Wheelchair Mobility.

    PubMed

    Slavens, Brooke A; Schnorenberg, Alyssa J; Aurit, Christine M; Tarima, Sergey; Vogel, Lawrence C; Harris, Gerald F

    2015-01-01

    Currently, there is limited research of the biomechanics of pediatric manual wheelchair mobility. Specifically, the biomechanics of functional tasks and their relationship to joint pain and health is not well understood. To contribute to this knowledge gap, a quantitative rehabilitation approach was applied for characterizing upper extremity biomechanics of manual wheelchair mobility in children and adolescents during propulsion, starting, and stopping tasks. A Vicon motion analysis system captured movement, while a SmartWheel simultaneously collected three-dimensional forces and moments occurring at the handrim. A custom pediatric inverse dynamics model was used to evaluate three-dimensional upper extremity joint motions, forces, and moments of 14 children with spinal cord injury (SCI) during the functional tasks. Additionally, pain and health-related quality of life outcomes were assessed. This research found that joint demands are significantly different amongst functional tasks, with greatest demands placed on the shoulder during the starting task. Propulsion was significantly different from starting and stopping at all joints. We identified multiple stroke patterns used by the children, some of which are not standard in adults. One subject reported average daily pain, which was minimal. Lower than normal physical health and higher than normal mental health was found in this population. It can be concluded that functional tasks should be considered in addition to propulsion for rehabilitation and SCI treatment planning. This research provides wheelchair users and clinicians with a comprehensive, biomechanical, mobility assessment approach for wheelchair prescription, training, and long-term care of children with SCI.

  7. Biomechanics of fencing sport: A scoping review

    PubMed Central

    Chen, Tony Lin-Wei; Wong, Duo Wai-Chi; Wang, Yan; Ren, Sicong; Yan, Fei

    2017-01-01

    Objectives The aim of our scoping review was to identify and summarize current evidence on the biomechanics of fencing to inform athlete development and injury prevention. Design Scoping review. Method Peer-reviewed research was identified from electronic databases using a structured keyword search. Details regarding experimental design, study group characteristics and measured outcomes were extracted from retrieved studies, summarized and information regrouped under themes for analysis. The methodological quality of the evidence was evaluated. Results Thirty-seven peer-reviewed studies were retrieved, the majority being observational studies conducted with experienced and elite athletes. The methodological quality of the evidence was “fair” due to the limited scope of research. Male fencers were the prevalent group studied, with the lunge and use of a foil weapon being the principal movement evaluated. Motion capture and pedabarography were the most frequently used data collection techniques. Conclusions Elite fencers exhibited sequential coordination of upper and lower limb movements with coherent patterns of muscle activation, compared to novice fencers. These elite features of neuromuscular coordination resulted in higher magnitudes of forward linear velocity of the body center of mass and weapon. Training should focus on explosive power. Sex- and equipment-specific effects could not be evaluated based on available research. PMID:28187164

  8. Translating ocular biomechanics into clinical practice: current state and future prospects.

    PubMed

    Girard, Michaël J A; Dupps, William J; Baskaran, Mani; Scarcelli, Giuliano; Yun, Seok H; Quigley, Harry A; Sigal, Ian A; Strouthidis, Nicholas G

    2015-01-01

    Biomechanics is the study of the relationship between forces and function in living organisms and is thought to play a critical role in a significant number of ophthalmic disorders. This is not surprising, as the eye is a pressure vessel that requires a delicate balance of forces to maintain its homeostasis. Over the past few decades, basic science research in ophthalmology mostly confirmed that ocular biomechanics could explain in part the mechanisms involved in almost all major ophthalmic disorders such as optic nerve head neuropathies, angle closure, ametropia, presbyopia, cataract, corneal pathologies, retinal detachment and macular degeneration. Translational biomechanics in ophthalmology, however, is still in its infancy. It is believed that its use could make significant advances in diagnosis and treatment. Several translational biomechanics strategies are already emerging, such as corneal stiffening for the treatment of keratoconus, and more are likely to follow. This review aims to cultivate the idea that biomechanics plays a major role in ophthalmology and that the clinical translation, lead by collaborative teams of clinicians and biomedical engineers, will benefit our patients. Specifically, recent advances and future prospects in corneal, iris, trabecular meshwork, crystalline lens, scleral and lamina cribrosa biomechanics are discussed.

  9. Translating Ocular Biomechanics into Clinical Practice: Current State and Future Prospects

    PubMed Central

    Girard, Michaël J.A.; Dupps, William J.; Baskaran, Mani; Scarcelli, Giuliano; Yun, Seok H.; Quigley, Harry A.; Sigal, Ian A.; Strouthidis, Nicholas G.

    2014-01-01

    Biomechanics – the study of the relationship between forces and function in living organisms – is thought to play a critical role in a significant number of ophthalmic disorders. This is not surprising, as the eye is a pressure vessel that requires a delicate balance of forces to maintain its homeostasis. Over the past few decades, basic science research in ophthalmology mostly confirmed that ocular biomechanics could explain in part the mechanisms involved in almost all major ophthalmic disorders such as optic nerve head neuropathies, angle closure, ametropia, presbyopia, cataract, corneal pathologies, retinal detachment, and macular degeneration. Translational biomechanics in ophthalmology, however, is still in its infancy. It is believed that its use could make significant advances in diagnosis and treatment. Several translational biomechanics strategies are already emerging, such as corneal stiffening for the treatment of keratoconus, and more are likely to follow. This review aims to cultivate the idea that biomechanics plays a major role in ophthalmology and that its clinical translation, lead by collaborative teams of clinicians and biomedical engineers, will benefit our patients. Specifically, recent advances and future prospects in corneal, iris, trabecular meshwork, crystalline lens, scleral and lamina cribrosa biomechanics are discussed. PMID:24832392

  10. Biomechanics of Wheat/Barley Straw and Corn Stover

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher T. Wright; Peter A. Pryfogle; Nathan A. Stevens

    2005-03-01

    The lack of understanding of the mechanical characteristics of cellulosic feedstocks is a limiting factor in economically collecting and processing crop residues, primarily wheat and barley stems and corn stover. Several testing methods, including compression, tension, and bend have been investigated to increase our understanding of the biomechanical behavior of cellulosic feedstocks. Biomechanical data from these tests can provide required input to numerical models and help advance harvesting, handling, and processing techniques. In addition, integrating the models with the complete data set from this study can identify potential tools for manipulating the biomechanical properties of plant varieties in such amore » manner as to optimize their physical characteristics to produce higher value biomass and more energy efficient harvesting practices.« less

  11. Challenge-Based Instruction: The VaNTH Biomechanics Learning Modules

    ERIC Educational Resources Information Center

    Barr, Ronald E.; Pandy, Marcus G.; Petrosino, Anthony J.; Roselli, Robert J.; Brophy, Sean; Freeman, Robert A.

    2007-01-01

    This paper presents the methodology and results of teaching an entire engineering course using challenge-based instruction. The challenges consisted of eight biomechanics multimedia learning modules developed by the authors as part of a broader NSF educational coalition. The biomechanics modules were presented in an undergraduate mechanical…

  12. The Assignment of Scale to Object-Oriented Software Measures

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.; Weistroffer, H. Roland; Coppins, Richard J.

    1997-01-01

    In order to improve productivity (and quality), measurement of specific aspects of software has become imperative. As object oriented programming languages have become more widely used, metrics designed specifically for object-oriented software are required. Recently a large number of new metrics for object- oriented software has appeared in the literature. Unfortunately, many of these proposed metrics have not been validated to measure what they purport to measure. In this paper fifty (50) of these metrics are analyzed.

  13. The effects of tibiofibularis anterior ligaments on ankle joint biomechanics.

    PubMed

    Karakaşlı, Ahmet; Erduran, Mehmet; Baktıroğlu, Lütfü; Büdeyri, Aydın; Yıldız, Didem Venüs; Havıtçıoğlu, Hasan

    2015-03-01

    The aim of this study was to evaluate the biomechanical behavior of anterior inferior tibiofibularis ligament (AITFL) deficient human ankle under axial loading of ankle at stance phase of gait. In order to investigate the contribution of AITFL to ankle stability, an in vitro sequential experimental setup was simulated. The measurement of posterior displacement of distal tibia and anterior displacement of the foot, in neutral position, secondary to axial compression, was performed by two non-contact video extensometers. Eight freshly frozen, anatomically intact, cadaveric human ankle specimens were included and tested. An axial compression test machine was utilized from 0 to 800 Newtonswith a loading speed of 5 mm/min in order to simulate the axial weight-bearing sequence of the ankle at stance phase of human gait. There was a statistically significant difference between anteroposterior displacement values for AITFL-Intact and AITFL-Dissected specimens (p≤0.05). Mean AITFL-Intact and mean AITFL-Dissected ankle anteroposterior displacement was 1.28±0.47 mm and 2.06±0.7 mm, respectively. This study determined some numerical and quantitative data about the biomechanical properties of AITFL in neutral foot position. In the emergency department, diagnosis and treatment of AITFL injury, due to ankle distortion, is important. In AITFL injuries, ankle biomechanics is affected, and ankle instability occurs.

  14. Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture.

    PubMed

    Zhang, Wei; Luo, Cong-Feng; Putnis, Sven; Sun, Hui; Zeng, Zhi-Min; Zeng, Bing-Fang

    2012-03-01

    The posterolateral shearing tibial plateau fracture is uncommon in the literature, however with the increased usage of computer tomography (CT), the incidence of these fractures is no longer as low as previously thought. Few studies have concentrated on this fracture, least of all using a biomechanical model. The purpose of this study was to compare and analyse the biomechanical characteristics of four different types of internal fixation to stabilise the posterolateral shearing tibial plateau fracture. Forty synthetic tibiae (Synbone, right) simulated the posterolateral shearing fracture models and these were randomly assigned into four groups; Group A was fixed with two anterolateral lag screws, Group B with an anteromedial Limited Contact Dynamic Compression Plate (LC-DCP), Group C with a lateral locking plate, and Group D with a posterolateral buttress plate. Vertical displacement of the posterolateral fragment was measured using three different strengths of axial loading force, and finally loaded until fixation failure. It was concluded that the posterolateral buttress plate is biomechanically the strongest fixation method for the posterolateral shearing tibial plateau fracture. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate

    PubMed Central

    Viberg, Bjarke; Rasmussen, Katrine M V; Overgaard, Søren; Rogmark, Cecilia

    2017-01-01

    Background and purpose The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between biomechanical and clinical studies on PF-LCP. Methods A systematic literature search of relevant biomechanical and clinical studies was conducted in PubMed on December 1, 2015. 7 biomechanical studies and 15 clinical studies were included. Results Even though the biomechanical studies showed equivalent or higher failure loads for femoral neck fracture, the clinical results were far worse, with a 37% complication rate. There were no biomechanical studies on pertrochanteric fractures. Biomechanical studies on subtrochanteric fractures showed that PF-LCP had a lower failure load than with proximal femoral nail, but higher than with angled blade plate. 4 clinical studies had complication rates less than 8% and 9 studies had complication rates between 15% and 53%. Interpretation There was no clear relation between biomechanical and clinical studies. Biomechanical studies are generally inherently different from clinical studies, as they examine the best possible theoretical use of the implant without considering the long-term outcome in a clinical setting. Properly designed clinical studies are mandatory when introducing new implants, and they cannot be replaced by biomechanical studies. PMID:28287002

  16. The History of Biomechanics in Total Hip Arthroplasty.

    PubMed

    Houcke, Jan Van; Khanduja, Vikas; Pattyn, Christophe; Audenaert, Emmanuel

    2017-01-01

    Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro , in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA). The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.

  17. Biomechanics of penetrating trauma.

    PubMed

    Yoganandan, N; Pintar, F A

    1997-01-01

    It is well known that injuries and deaths due to penetrating projectiles have become a national and an international epidemic in Western society. The application of biomedical engineering to solve day-to-day problems has produced considerable advances in safety and mitigation/prevention of trauma. The study of penetrating trauma has been largely in the military domain where war-time specific applications were advanced with the use of high-velocity weapons. With the velocity and weapon caliber in the civilian population at half or less compared with the military counterpart, wound ballistics is a largely different problem in today's trauma centers. The principal goal of the study of penetrating injuries in the civilian population is secondary prevention and optimized emergency care after occurrence. A thorough understanding of the dynamic biomechanics of penetrating injuries quantifies missile type, caliber, and velocity to hard and soft tissue damage. Such information leads to a comprehensive assessment of the acute and long-term treatment of patients with penetrating injuries. A review of the relevant military research applied to the civilian domain and presentation of new technology in the biomechanical study of these injuries offer foundation to this field. Relevant issues addressed in this review article include introduction of the military literature, the need for secondary prevention, environmental factors including projectile velocity and design, experimental studies with biological tissues and physical models, and mathematical simulations and analyses. Areas of advancement are identified that enables the pursuit of biomechanics research in order to arrive at better secondary prevention strategies.

  18. Sex Differences in Task Distribution and Task Exposures among Danish House Painters: An Observational Study Combining Questionnaire Data with Biomechanical Measurements

    PubMed Central

    Heilskov-Hansen, Thomas; Wulff Svendsen, Susanne; Frølund Thomsen, Jane; Mikkelsen, Sigurd; Hansson, Gert-Åke

    2014-01-01

    Objectives Sex differences in occupational biomechanical exposures may be part of the explanation why musculoskeletal complaints and disorders tend to be more common among women than among men. We aimed to determine possible sex differences in task distribution and task-specific postures and movements of the upper extremities among Danish house painters, and to establish sex-specific task exposure matrices. Methods To obtain task distributions, we sent out a questionnaire to all members of the Painters' Union in Denmark (N = 9364), of whom 53% responded. Respondents reported their task distributions in a typical week. To obtain task exposures, postures and movements were measured in 25 male and 25 female house painters for one whole working day per person. We used goniometers on the wrists, and inclinometers on the forehead and the upper arms. Participants filled in a logbook allowing task-specific exposures to be identified. Percentiles and % time with non-neutral postures were used to characterise postures. Velocity, range of motion, repetitiveness, and variation were used as measures of movement. Cochran-Mantel-Haenszel statistics and unpaired double-sided t-tests with post-hoc Bonferroni correction were used to evaluate sex differences. Results Statistically significant (p<0.05) sex differences were revealed in task proportions, but the proportions differed by less than 4%. For task exposures, no statistically significant sex differences were found. Conclusions Only minor sex differences were found in task distribution and task exposures regarding postures and movements among Danish house painters. Sex-specific task exposure matrices were established. PMID:25365301

  19. A Development of Force Plate for Biomechanics Analysis of Standing and Walking

    NASA Astrophysics Data System (ADS)

    Wardoyo, S.; Hutajulu, P. T.; Togibasa, O.

    2016-08-01

    Force plates are known as an excellent teaching aid to demonstrate the kinematics and dynamics of motion and commonly used in biomechanics laboratories to measure ground forces involved in the motion of human. It is consist of a metal plate with sensors attached to give an electrical output proportional to the force on the plate. Moreover, force plates are useful for examining the kinetic characteristics of an athlete's movement. They provide information about the external forces involved in movement that can aid a coach or sports scientist to quantitatively evaluate the athlete's skill development. In this study, we develop our prototype of force plate with less than 100,- simply by using flexible force transducer attached inside rubber matt, in the form of square blocks (dimension: 250 mm × 150 mm × 10 mm), with maximum load up to 60 kg. The handmade force plate was tested by applying biomechanics analysis for standing and walking. The testing was done on Experimental Soccer Courses’ students at the Department of Physical Education, Health and Recreation, University of Cenderawasih. The design of the force plate system together with biomechanics analysis will be discussed.

  20. A Fuzzy Description Logic with Automatic Object Membership Measurement

    NASA Astrophysics Data System (ADS)

    Cai, Yi; Leung, Ho-Fung

    In this paper, we propose a fuzzy description logic named f om -DL by combining the classical view in cognitive psychology and fuzzy set theory. A formal mechanism used to determine object memberships automatically in concepts is also proposed, which is lacked in previous work fuzzy description logics. In this mechanism, object membership is based on the defining properties of concept definition and properties in object description. Moreover, while previous works cannot express the qualitative measurements of an object possessing a property, we introduce two kinds of properties named N-property and L-property, which are quantitative measurements and qualitative measurements of an object possessing a property respectively. The subsumption and implication of concepts and properties are also explored in our work. We believe that it is useful to the Semantic Web community for reasoning the fuzzy membership of objects for concepts in fuzzy ontologies.

  1. Biomechanics of the elbow joint in tennis players and relation to pathology.

    PubMed

    Eygendaal, Denise; Rahussen, F Th G; Diercks, R L

    2007-11-01

    Elbow injuries constitute a sizeable percentage of tennis injuries. A basic understanding of biomechanics of tennis and analysis of the forces, loads and motions of the elbow during tennis will improve the understanding of the pathophysiology of these injuries. All different strokes in tennis have a different repetitive biomechanical nature that can result in tennis-related injuries. In this article, a biomechanically-based evaluation of tennis strokes is presented. This overview includes all tennis-related pathologies of the elbow joint, whereby the possible relation of biomechanics to pathology is analysed, followed by treatment recommendations.

  2. Foot orthoses in the treatment of symptomatic midfoot osteoarthritis using clinical and biomechanical outcomes: a randomised feasibility study.

    PubMed

    Halstead, Jill; Chapman, Graham J; Gray, Janine C; Grainger, Andrew J; Brown, Sarah; Wilkins, Richard A; Roddy, Edward; Helliwell, Philip S; Keenan, Anne-Maree; Redmond, Anthony C

    2016-04-01

    This randomised feasibility study aimed to examine the clinical and biomechanical effects of functional foot orthoses (FFOs) in the treatment of midfoot osteoarthritis (OA) and the feasibility of conducting a full randomised controlled trial. Participants with painful, radiographically confirmed midfoot OA were recruited and randomised to receive either FFOs or a sham control orthosis. Feasibility measures included recruitment and attrition rates, practicality of blinding and adherence rates. Clinical outcome measures were: change from baseline to 12 weeks for severity of pain (numerical rating scale), foot function (Manchester Foot Pain and Disability Index) and patient global impression of change scale. To investigate the biomechanical effect of foot orthoses, in-shoe foot kinematics and plantar pressures were evaluated at 12 weeks. Of the 119 participants screened, 37 were randomised and 33 completed the study (FFO = 18, sham = 15). Compliance with foot orthoses and blinding of the intervention was achieved in three quarters of the group. Both groups reported improvements in pain, function and global impression of change; the FFO group reporting greater improvements compared to the sham group. The biomechanical outcomes indicated the FFO group inverted the hindfoot and increased midfoot maximum plantar force compared to the sham group. The present findings suggest FFOs worn over 12 weeks may provide detectable clinical and biomechanical benefits compared to sham orthoses. This feasibility study provides useful clinical, biomechanical and statistical information for the design and implementation of a definitive randomised controlled trial to evaluate the effectiveness of FFOs in treating painful midfoot OA.

  3. Digital image measurement of specimen deformation based on CCD cameras and Image J software: an application to human pelvic biomechanics

    NASA Astrophysics Data System (ADS)

    Jia, Yongwei; Cheng, Liming; Yu, Guangrong; Lou, Yongjian; Yu, Yan; Chen, Bo; Ding, Zuquan

    2008-03-01

    A method of digital image measurement of specimen deformation based on CCD cameras and Image J software was developed. This method was used to measure the biomechanics behavior of human pelvis. Six cadaveric specimens from the third lumbar vertebra to the proximal 1/3 part of femur were tested. The specimens without any structural abnormalities were dissected of all soft tissue, sparing the hip joint capsules and the ligaments of the pelvic ring and floor. Markers with black dot on white background were affixed to the key regions of the pelvis. Axial loading from the proximal lumbar was applied by MTS in the gradient of 0N to 500N, which simulated the double feet standing stance. The anterior and lateral images of the specimen were obtained through two CCD cameras. Based on Image J software, digital image processing software, which can be freely downloaded from the National Institutes of Health, digital 8-bit images were processed. The procedure includes the recognition of digital marker, image invert, sub-pixel reconstruction, image segmentation, center of mass algorithm based on weighted average of pixel gray values. Vertical displacements of S1 (the first sacral vertebrae) in front view and micro-angular rotation of sacroiliac joint in lateral view were calculated according to the marker movement. The results of digital image measurement showed as following: marker image correlation before and after deformation was excellent. The average correlation coefficient was about 0.983. According to the 768 × 576 pixels image (pixel size 0.68mm × 0.68mm), the precision of the displacement detected in our experiment was about 0.018 pixels and the comparatively error could achieve 1.11\\perthou. The average vertical displacement of S1 of the pelvis was 0.8356+/-0.2830mm under vertical load of 500 Newtons and the average micro-angular rotation of sacroiliac joint in lateral view was 0.584+/-0.221°. The load-displacement curves obtained from our optical measure system

  4. In vivo ocular biomechanical compliance in thyroid eye disease.

    PubMed

    Vellara, Hans R; Hart, Richard; Gokul, Akilesh; McGhee, Charles N J; Patel, Dipika V

    2017-08-01

    To compare the ocular biomechanical properties in patients with thyroid eye disease (TED) and healthy participants using a non-contact Scheimpflug-based tonometer (CorVis ST). All eyes were examined by slit lamp biomicroscopy, corneal tomography and the CorVis ST (CST). Patients with TED were examined by a fellowship trained oculoplastics specialist to determine status and assess severity. The outputs from CST and additionally derived parameters, including maximum orbital deformation (MOD), were compared between healthy participants and patients with TED using Student's t-test. Furthermore, a multiple linear regression analysis was used to control for various factors known to influence ocular biomechanical responses to an air pulse. This study included 20 patients with TED and compared them with a cohort of 152 healthy participants. The mean age of patients with TED was 46.7±19.0 years and the mean age of healthy participants was 35.9±13.8 years (p=0.03). There were no statistically significant differences in gender distributions between both groups (p>0.05). Several CST parameters were significantly different between groups (p<0.05). Of note, however, MOD was significantly lower in patients with TED (0.16±0.04 mm) compared with the healthy participants (0.25±0.05 mm, p<0.001). This dissimilarity remained even after controlling for the various cofactors. Receiver-operating characteristic analysis revealed an area under the curve of 0.91±0.04 (95% CI 0.84 to 0.98, p<0.001) for MOD. The in vivo ocular biomechanics as measured by the CST reflects a reduced orbital compliance. This method of ocular biomechanical assessment may aid in the categorisation of TED severity and assist in monitoring and/or diagnosing TED. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Biomechanics of compensatory mechanisms in spinal-pelvic complex

    NASA Astrophysics Data System (ADS)

    Ivanov, D. V.; Hominets, V. V.; Kirillova, I. V.; Kossovich, L. Yu; Kudyashev, A. L.; Teremshonok, A. V.

    2018-04-01

    3D geometric solid computer model of spinal-pelvic complex was constructed on the basis of computed tomography and full body X-ray in standing position data. The constructed model was used for biomechanical analysis of compensatory mechanisms arising in the spine with anteversion and retroversion of the pelvis. The results of numerical biomechanical 3D modeling are in good agreement with the clinical data.

  6. Objective and automated measurement of dynamic vision functions

    NASA Technical Reports Server (NTRS)

    Flom, M. C.; Adams, A. J.

    1976-01-01

    A phoria stimulus array and electro-oculographic (EOG) arrangements for measuring motor and sensory responses of subjects subjected to stress or drug conditions are described, along with experimental procedures. Heterophoria (as oculomotor function) and glare recovery time (time required for photochemical and neural recovery after exposure to a flash stimulus) are measured, in research aimed at developing automated objective measurement of dynamic vision functions. Onset of involuntary optokinetic nystagmus in subjects attempting to track moving stripes (while viewing through head-mounted binocular eyepieces) after exposure to glare serves as an objective measure of glare recovery time.

  7. Lateral Augmentation Procedures in Anterior Cruciate Ligament Reconstruction: Anatomic, Biomechanical, Imaging, and Clinical Evidence.

    PubMed

    Weber, Alexander E; Zuke, William; Mayer, Erik N; Forsythe, Brian; Getgood, Alan; Verma, Nikhil N; Bach, Bernard R; Bedi, Asheesh; Cole, Brian J

    2018-02-01

    There has been an increasing interest in lateral-based soft tissue reconstructive techniques as augments to anterior cruciate ligament reconstruction (ACLR). The objective of these procedures is to minimize anterolateral rotational instability of the knee after surgery. Despite the relatively rapid increase in surgical application of these techniques, many clinical questions remain. To provide a comprehensive update on the current state of these lateral-based augmentation procedures by reviewing the origins of the surgical techniques, the biomechanical data to support their use, and the clinical results to date. Systematic review. A systematic search of the literature was conducted via the Medline, EMBASE, Scopus, SportDiscus, and CINAHL databases. The search was designed to encompass the literature on lateral extra-articular tenodesis (LET) procedures and the anterolateral ligament (ALL) reconstruction. Titles and abstracts were reviewed for relevance and sorted into the following categories: anatomy, biomechanics, imaging/diagnostics, surgical techniques, and clinical outcomes. The search identified 4016 articles. After review for relevance, 31, 53, 27, 35, 45, and 78 articles described the anatomy, biomechanics, imaging/diagnostics, surgical techniques, and clinical outcomes of either LET procedures or the ALL reconstruction, respectively. A multitude of investigations were available, revealing controversy in addition to consensus in several categories. The level of evidence obtained from this search was not adequate for systematic review or meta-analysis; thus, a current concepts review of the anatomy, biomechanics, imaging, surgical techniques, and clinical outcomes was performed. Histologically, the ALL appears to be a distinct structure that can be identified with advanced imaging techniques. Biomechanical evidence suggests that the anterolateral structures of the knee, including the ALL, contribute to minimizing anterolateral rotational instability

  8. Physiological, Biomechanical and Anthropometrical Predictors of Sprint Swimming Performance in Adolescent Swimmers

    PubMed Central

    Lätt, Evelin; Jürimäe, Jaak; Mäestu, Jarek; Purge, Priit; Rämson, Raul; Haljaste, Kaja; Keskinen, Kari L.; Rodriguez, Ferran A.; Jürimäe, Toivo

    2010-01-01

    The purpose of this study was to analyze the relationships between 100-m front crawl swimming performance and relevant biomechanical, anthropometrical and physiological parameters in male adolescent swimmers. Twenty five male swimmers (mean ± SD: age 15. 2 ± 1.9 years; height 1.76 ± 0.09 m; body mass 63.3 ± 10.9 kg) performed an all-out 100-m front crawl swimming test in a 25-m pool. A respiratory snorkel and valve system with low hydrodynamic resistance was used to collect expired air. Oxygen uptake was measured breath-by-breath by a portable metabolic cart. Swimming velocity, stroke rate (SR), stroke length and stroke index (SI) were assessed during the test by time video analysis. Blood samples for lactate measurement were taken from the fingertip pre exercise and at the third and fifth minute of recovery to estimate net blood lactate accumulation (ΔLa). The energy cost of swimming was estimated from oxygen uptake and blood lactate energy equivalent values. Basic anthropometry included body height, body mass and arm span. Body composition parameters were measured using dual-energy X-ray absorptiometry (DXA). Results indicate that biomechanical factors (90.3%) explained most of 100-m front crawl swimming performance variability in these adolescent male swimmers, followed by anthropometrical (45.8%) and physiological (45.2%) parameters. SI was the best single predictor of performance, while arm span and ∆La were the best anthropometrical and physiological indicators, respectively. SI and SR alone explained 92.6% of the variance in competitive performance. These results confirm the importance of considering specific stroke technical parameters when predicting success in young swimmers. Key points This study investigated the influence of different anthropometrical, physiological and biomechanical parameters on 100-m swimming performance in adolescent boys. Biomechanical factors contributed most to sprint swimming performance in these young male swimmers (90

  9. ON THE BIOMECHANICS OF HEART VALVE FUNCTION

    PubMed Central

    Sacks, Michael S.; Merryman, W. David; Schmidt, David E.

    2009-01-01

    Heart valves (HVs) are fluidic control components of the heart that ensure unidirectional blood flow during the cardiac cycle. However, this description does not adequately describe the biomechanical ramifications of their function in that their mechanics are multi-modal. Moreover, they must replicate their cyclic function over an entire lifetime, with an estimated total functional demand of least 3×109 cycles. The focus of the present review is on the functional biomechanics of heart valves. Thus, the focus of the present review is on functional biomechanics, referring primarily to biosolid as well as several key biofluid mechanical aspects underlying heart valve physiological function. Specifically, we refer to the mechanical behaviors of the extra-cellular matrix structural proteins, underlying cellular function, and their integrated relation to the major aspects of valvular hemodynamic function. While we focus on the work from the author’s laboratories, relevant works of other investigators have been included whenever appropriate. We conclude with a summary of important future trends. PMID:19540499

  10. Restoring Segmental Biomechanics Through Nucleus Augmentation: An In Vitro Study.

    PubMed

    Pelletier, Matthew H; Cohen, Charles S; Ducheyne, Paul; Walsh, William R

    2016-12-01

    In vitro biomechanical laboratory study. The purpose of this study is to evaluate a mechanical treatment to create a degenerative motion segment and the ability of nucleus augmentation to restore biomechanics. In cases with an intact annulus fibrosus, the replacement or augmentation of the nucleus pulposus alone may provide a less invasive option to restore normal biomechanics and disk height when compared with spinal fusion or total disk replacement. Laboratory testing allows these changes to be fully characterized. However, without preexisting pathology, nucleus augmentation therapies are difficult to evaluate in vitro. The present study evaluated pure moment bending and compressive biomechanics in 3 states (n=6): (1) intact, (2) after creep loading and nucleus disruption to induce degenerative biomechanical changes, and (3) after nucleus augmentation through an injectable polymer (DiscCell). Neutral zone and ROM were increased in all modes of bending after the degenerative treatment. The most sensitive mode of bending was lateral bending, with intact ROM (20.0±2.9 degrees) increased to 22.3±2.6 degrees after degenerative treatment and reduced to 18.4±1.6 degrees after injection of the polymer. All bending ROM and NZ changes induced by the degenerative treatment were reversed by nucleus augmentation. This material was shown to be effective at altering motion segment biomechanics and restoring disk height during time zero tests. This technique may provide a model to examine the time zero performance of a nucleus augmentation device/material.

  11. Changes in drop-jump landing biomechanics during prolonged intermittent exercise.

    PubMed

    Schmitz, Randy J; Cone, John C; Tritsch, Amanda J; Pye, Michele L; Montgomery, Melissa M; Henson, Robert A; Shultz, Sandra J

    2014-03-01

    As injury rates rise in the later stages of sporting activities, a better understanding of lower extremity biomechanics in the later phases of gamelike situations may improve training and injury prevention programs. Lower extremity biomechanics of a drop-jump task (extracted from a principal components analysis) would reveal factors associated with risk of anterior cruciate ligament injury during a 90-minute individualized intermittent exercise protocol (IEP) and for 1 hour following the IEP. Controlled laboratory study. Level 4. Fifty-nine athletes (29 women, 30 men) completed 3 sessions. The first session assessed fitness for an IEP designed to simulate the demands of a soccer match. An experimental session assessed drop-jump biomechanics, after a dynamic warm-up, every 15 minutes during the 90-minute IEP, and for 1 hour following the IEP. A control session with no exercise assessed drop-jump performance at the same intervals. Two biomechanical factors early in the first half (hip flexion at initial contact and hip loading; ankle loading and knee shear force) decreased at the end of the IEP and into the 60-minute recovery period, while a third factor (knee loading) decreased only during the recovery period (P ≤ 0.05). The individualized sport-specific IEP may have more subtle effects on landing biomechanics when compared with short-term, exhaustive fatigue protocols. Potentially injurious landing biomechanics may not occur until the later stages of soccer activity.

  12. Changes in Drop-Jump Landing Biomechanics During Prolonged Intermittent Exercise

    PubMed Central

    Schmitz, Randy J.; Cone, John C.; Tritsch, Amanda J.; Pye, Michele L.; Montgomery, Melissa M.; Henson, Robert A.; Shultz, Sandra J.

    2014-01-01

    Background: As injury rates rise in the later stages of sporting activities, a better understanding of lower extremity biomechanics in the later phases of gamelike situations may improve training and injury prevention programs. Hypothesis: Lower extremity biomechanics of a drop-jump task (extracted from a principal components analysis) would reveal factors associated with risk of anterior cruciate ligament injury during a 90-minute individualized intermittent exercise protocol (IEP) and for 1 hour following the IEP. Study Design: Controlled laboratory study. Level of Evidence: Level 4. Methods: Fifty-nine athletes (29 women, 30 men) completed 3 sessions. The first session assessed fitness for an IEP designed to simulate the demands of a soccer match. An experimental session assessed drop-jump biomechanics, after a dynamic warm-up, every 15 minutes during the 90-minute IEP, and for 1 hour following the IEP. A control session with no exercise assessed drop-jump performance at the same intervals. Results: Two biomechanical factors early in the first half (hip flexion at initial contact and hip loading; ankle loading and knee shear force) decreased at the end of the IEP and into the 60-minute recovery period, while a third factor (knee loading) decreased only during the recovery period (P ≤ 0.05). Conclusion: The individualized sport-specific IEP may have more subtle effects on landing biomechanics when compared with short-term, exhaustive fatigue protocols. Clinical Relevance: Potentially injurious landing biomechanics may not occur until the later stages of soccer activity. PMID:24587862

  13. In Vivo Multiphoton Microscopy for Investigating Biomechanical Properties of Human Skin.

    PubMed

    Liang, Xing; Graf, Benedikt W; Boppart, Stephen A

    2011-06-01

    The biomechanical properties of living cells depend on their molecular building blocks, and are important for maintaining structure and function in cells, the extracellular matrix, and tissues. These biomechanical properties and forces also shape and modify the cellular and extracellular structures under stress. While many studies have investigated the biomechanics of single cells or small populations of cells in culture, or the properties of organs and tissues, few studies have investigated the biomechanics of complex cell populations in vivo. With the use of advanced multiphoton microscopy to visualize in vivo cell populations in human skin, the biomechanical properties are investigated in a depth-dependent manner in the stratum corneum and epidermis using quasi-static mechanical deformations. A 2D elastic registration algorithm was used to analyze the images before and after deformation to determine displacements in different skin layers. In this feasibility study, the images and results from one human subject demonstrate the potential of the technique for revealing differences in elastic properties between the stratum corneum and the rest of the epidermis. This interrogational imaging methodology has the potential to enable a wide range of investigations for understanding how the biomechanical properties of in vivo cell populations influence function in health and disease.

  14. A method to investigate the biomechanical alterations in Perthes' disease by hip joint contact modeling.

    PubMed

    Salmingo, Remel Alingalan; Skytte, Tina Lercke; Traberg, Marie Sand; Mikkelsen, Lars Pilgaard; Henneberg, Kaj-Åge; Wong, Christian

    2017-01-01

    Perthes' disease is a destructive hip joint disorder characterized by malformation of the femoral head in young children. While the morphological changes have been widely studied, the biomechanical effects of these changes still need to be further elucidated. The objective of this study was to develop a method to investigate the biomechanical alterations in Perthes' disease by finite element (FE) contact modeling using MRI. The MRI data of a unilateral Perthes' case was obtained to develop the three-dimensional FE model of the hip joint. The stress and contact pressure patterns in the unaffected hip were well distributed. Elevated concentrations of stress and contact pressure were found in the Perthes' hip. The highest femoral cartilage von Mises stress 3.9 MPa and contact pressure 5.3 MPa were found in the Perthes' hip, whereas 2.4 MPa and 4.9 MPa in the healthy hip, respectively. The healthy bone in the femoral head of the Perthes' hip carries additional loads as indicated by the increase of stress levels around the necrotic-healthy bone interface. Identifying the biomechanical changes, such as the location of stress and contact pressure concentrations, is a prerequisite for the preoperative planning to obtain stress relief for the highly stressed areas in the malformed hip. This single-patient study demonstrated that the biomechanical alterations in Perthes' disease can be evaluated individually by patient-specific finite element contact modeling using MRI. A multi-patient study is required to test the strength of the proposed method as a pre-surgery planning tool.

  15. Biomechanical performance of baseball pitchers with a history of ulnar collateral ligament reconstruction.

    PubMed

    Fleisig, Glenn S; Leddon, Charles E; Laughlin, Walter A; Ciccotti, Michael G; Mandelbaum, Bert R; Aune, Kyle T; Escamilla, Rafael F; MacLeod, Toran D; Andrews, James R

    2015-05-01

    A relatively high number of active professional baseball pitchers have a history of ulnar collateral ligament reconstruction (UCLr) on their throwing elbow. Controversy exists in the literature about whether professional baseball pitchers regain optimal performance after return from UCLr. It has been suggested that pitchers may have different biomechanics after UCLr, but this has not been previously tested. It was hypothesized that, compared with a control group without a history of UCLr, professional pitchers with a history of UCLr would have (1) significantly different throwing elbow and shoulder biomechanics; (2) a shortened stride, insufficient trunk forward tilt, and excessive shoulder horizontal adduction, characteristics associated with "holding back" or being tentative; (3) late shoulder rotation; and (4) improper shoulder abduction and trunk lateral tilt. Controlled laboratory study. A total of 80 active minor league baseball pitchers (and their 8 Major League Baseball organizations) agreed to participate in this study. Participants included 40 pitchers with a history of UCLr and a matched control group of 40 pitchers with no history of elbow or shoulder surgery. Passive ranges of motion were measured for each pitcher's elbows and shoulders, and then 23 reflective markers were attached to his body. The pitcher took as many warm-up pitches as desired and then threw 10 full-effort fastballs for data collection. Ball speed was recorded with a radar gun. The reflective markers were tracked with a 10-camera, 240-Hz automated motion analysis system. Eleven biomechanical parameters were computed for each pitch and then averaged for each participant. Demographic, range of motion, and biomechanical parameters were compared between the UCLr group and the control group by use of Student t tests (significance set at P<.05). All hypotheses were rejected, as there were no differences in pitching biomechanics between the UCLr group and the control group. There were also

  16. Female Pelvic Floor Biomechanics: Bridging the Gap

    PubMed Central

    Easley, Deanna C.; Abramowitch, Steven D.; Moalli, Pamela A.

    2017-01-01

    Purpose of review The pelvic floor is a complex assembly of connective tissues and striated muscle that simultaneously counteract gravitational forces, inertial forces, and intraabdominal pressures while maintaining the position of the pelvic organs. In 30% of women, injury or failure of the pelvic floor results in pelvic organ prolapse (POP). Surgical treatments have high recurrence rates, due, in part, to a limited understanding of physiologic loading conditions. It is critical to apply biomechanics to help elucidate how altered loading conditions of the pelvis contribute to the development of pelvic organ prolapse and to define surgeries to restore normal support. Recent findings Evidence suggests the ewe is a potential animal model for studying vaginal properties and that uterosacral and cardinal ligaments experience significant creep, which may be affecting surgical outcomes. A new method of measuring ligament displacements in vivo was developed, and finite element models that simulate urethral support, pelvic floor dynamics, and the impact of episiotomies on the pelvic floor were studied. Summary This review highlights some contributions over the past year, including mechanical testing and the creation of models, which are used to understand pelvic floor changes with loading, and the impact of surgical procedures, to illustrate how biomechanics is being utilized. PMID:28267057

  17. Dual-task and anticipation impact lower limb biomechanics during a single-leg cut with body borne load.

    PubMed

    Seymore, Kayla D; Cameron, Sarah E; Kaplan, Jonathan T; Ramsay, John W; Brown, Tyler N

    2017-12-08

    This study quantified how a dual cognitive task impacts lower limb biomechanics during anticipated and unanticipated single-leg cuts with body borne load. Twenty-four males performed anticipated and unanticipated cuts with and without a dual cognitive task with three load conditions: no load (∼6 kg), medium load (15% of BW), and heavy load (30% of BW). Lower limb biomechanics were submitted to a repeated measures linear mixed model to test the main and interaction effects of load, anticipation, and dual task. With body borne load, participants increased peak stance (PS) hip flexion (p = .004) and hip internal rotation (p = .001) angle, and PS hip flexion (p = .001) and internal rotation (p = .018), and knee flexion (p = .016) and abduction (p = .001) moments. With the dual task, participants decreased PS knee flexion angle (p < .001) and hip flexion moment (p = .027), and increased PS knee external rotation angle (p = .034). During the unanticipated cut, participants increased PS hip (p = .040) and knee flexion angle (p < .001), and decreased PS hip adduction (p = .001), and knee abduction (p = .005) and external rotation (p = .026) moments. Adding body borne load produces lower limb biomechanical adaptations thought to increase risk of musculoskeletal injury, but neither anticipation nor dual task exaggerated those biomechanical adaptations. With a dual task, participants adopted biomechanics known to increase injury risk; whereas, participants used lower limb biomechanics thought to decrease injury risk during unanticipated cuts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Biomechanical Evaluation of a Novel Apatite-Wollastonite Ceramic Cage Design for Lumbar Interbody Fusion: A Finite Element Model Study

    PubMed Central

    Şenköylü, Alpaslan; Aktaş, Erdem; Sarıkaya, Baran; Sipahioğlu, Serkan; Gürbüz, Rıza; Timuçin, Muharrem

    2018-01-01

    Objectives Cage design and material properties play a crucial role in the long-term results, since interbody fusions using intervertebral cages have become one of the basic procedures in spinal surgery. Our aim is to design a novel Apatite-Wollastonite interbody fusion cage and evaluate its biomechanical behavior in silico in a segmental spinal model. Materials and Methods Mechanical properties for the Apatite-Wollastonite bioceramic cages were obtained by fitting finite element results to the experimental compression behavior of a cage prototype. The prototype was made from hydroxyapatite, pseudowollastonite, and frit by sintering. The elastic modulus of the material was found to be 32 GPa. Three intact lumbar vertebral segments were modelled with the ANSYS 12.0.1 software and this model was modified to simulate a Posterior Lumbar Interbody Fusion. Four cage designs in different geometries were analyzed in silico under axial loading, flexion, extension, and lateral bending. Results The K2 design had the best overall biomechanical performance for the loads considered. Maximum cage stress recorded was 36.7 MPa in compression after a flexion load, which was within the biomechanical limits of the cage. Conclusion Biomechanical analyses suggest that K2 bioceramic cage is an optimal design and reveals essential material properties for a stable interbody fusion. PMID:29581974

  19. Surface-based prostate registration with biomechanical regularization

    NASA Astrophysics Data System (ADS)

    van de Ven, Wendy J. M.; Hu, Yipeng; Barentsz, Jelle O.; Karssemeijer, Nico; Barratt, Dean; Huisman, Henkjan J.

    2013-03-01

    Adding MR-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound by using MRUS registration. A common approach is to use surface-based registration. We hypothesize that biomechanical modeling will better control deformation inside the prostate than a regular surface-based registration method. We developed a novel method by extending a surface-based registration with finite element (FE) simulation to better predict internal deformation of the prostate. For each of six patients, a tetrahedral mesh was constructed from the manual prostate segmentation. Next, the internal prostate deformation was simulated using the derived radial surface displacement as boundary condition. The deformation field within the gland was calculated using the predicted FE node displacements and thin-plate spline interpolation. We tested our method on MR guided MR biopsy imaging data, as landmarks can easily be identified on MR images. For evaluation of the registration accuracy we used 45 anatomical landmarks located in all regions of the prostate. Our results show that the median target registration error of a surface-based registration with biomechanical regularization is 1.88 mm, which is significantly different from 2.61 mm without biomechanical regularization. We can conclude that biomechanical FE modeling has the potential to improve the accuracy of multimodal prostate registration when comparing it to regular surface-based registration.

  20. [Modelling metallic bars in an orthopaedic laboratory: postural and biomechanical analysis].

    PubMed

    Draicchio, F; Miccio, A; Mari, S; Silvetti, A; Forzano, F; Ranavolo, A

    2012-01-01

    Aim of this work is to assess, with an objective technique (i.e. surface electromyography), the upper limb biomechanical load in workers specialized in manufacturing of orthopedic prostheses. We considered two different working configurations (workstation height at 105 and 110 cm) and three different materials to be modeled (aluminum, steel and titanium). Our results showed significant differences between aluminum/steel and titanium bars. As regards the working configurations, we found differences in the muscle activation patterns between the two heights, with an increased exertion of the shoulder muscles at 110 cm with respect to 105.

  1. Development of biomechanical models for human factors evaluations

    NASA Technical Reports Server (NTRS)

    Woolford, Barbara; Pandya, Abhilash; Maida, James

    1991-01-01

    Previewing human capabilities in a computer-aided engineering mode has assisted greatly in planning well-designed systems without the cost and time involved in mockups and engineering models. To date, the computer models have focused on such variables as field of view, accessibility and fit, and reach envelopes. Program outputs have matured from simple static pictures to animations viewable from any eyepoint. However, while kinematics models are available, there are few biomechanical models available for estimating strength and motion patterns. Those, such as Crew Chief, that are available are based on strength measurements taken in specific positions. Johnson Space Center is pursuing a biomechanical model which will use strength data collected on single joints at two or three velocities to attempt to predict compound motions of several joint simultaneously and the resulting force at the end effector. Two lines of research are coming together to produce this result. One is an attempt to use optimal control theory to predict joint motion in complex motions, and another is the development of graphical representation of human capabilities. The progress to date in this research is described.

  2. Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications

    PubMed Central

    Ambrósio, Jr, Renato; Correia, Fernando Faria; Lopes, Bernardo; Salomão, Marcella Q.; Luz, Allan; Dawson, Daniel G.; Elsheikh, Ahmed; Vinciguerra, Riccardo; Vinciguerra, Paolo; Roberts, Cynthia J.

    2017-01-01

    Background: Ectasia development occurs due to a chronic corneal biomechanical decompensation or weakness, resulting in stromal thinning and corneal protrusion. This leads to corneal steepening, increase in astigmatism, and irregularity. In corneal refractive surgery, the detection of mild forms of ectasia pre-operatively is essential to avoid post-operative progressive ectasia, which also depends on the impact of the procedure on the cornea. Method: The advent of 3D tomography is proven as a significant advancement to further characterize corneal shape beyond front surface topography, which is still relevant. While screening tests for ectasia had been limited to corneal shape (geometry) assessment, clinical biomechanical assessment has been possible since the introduction of the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Buffalo, USA) in 2005 and the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) in 2010. Direct clinical biomechanical evaluation is recognized as paramount, especially in detection of mild ectatic cases and characterization of the susceptibility for ectasia progression for any cornea. Conclusions: The purpose of this review is to describe the current state of clinical evaluation of corneal biomechanics, focusing on the most recent advances of commercially available instruments and also on future developments, such as Brillouin microscopy. PMID:28932334

  3. Development of a Comprehensive Osteochondral Allograft MRI Scoring System (OCAMRISS) With Histopathologic, Micro–Computed Tomography, and Biomechanical Validation

    PubMed Central

    Pallante-Kichura, Andrea L.; Bae, Won C.; Du, Jiang; Statum, Sheronda; Wolfson, Tanya; Gamst, Anthony C.; Cory, Esther; Amiel, David; Bugbee, William D.; Sah, Robert L.; Chung, Christine B.

    2014-01-01

    Objective: To describe and apply a semiquantitative MRI scoring system for multifeature analysis of cartilage defect repair in the knee by osteochondral allografts and to correlate this scoring system with histopathologic, micro–computed tomography (µCT), and biomechanical reference standards using a goat repair model. Design: Fourteen adult goats had 2 osteochondral allografts implanted into each knee: one in the medial femoral condyle and one in the lateral trochlea. At 12 months, goats were euthanized and MRI was performed. Two blinded radiologists independently rated 9 primary features for each graft, including cartilage signal, fill, edge integration, surface congruity, calcified cartilage integrity, subchondral bone plate congruity, subchondral bone marrow signal, osseous integration, and presence of cystic changes. Four ancillary features of the joint were also evaluated, including opposing cartilage, meniscal tears, synovitis, and fat-pad scarring. Comparison was made with histologic and µCT reference standards as well as biomechanical measures. Interobserver agreement and agreement with reference standards was assessed. Cohen’s κ, Spearman’s correlation, and Kruskal-Wallis tests were used as appropriate. Results: There was substantial agreement (κ > 0.6, P < 0.001) for each MRI feature and with comparison against reference standards, except for cartilage edge integration (κ = 0.6). There was a strong positive correlation between MRI and reference standard scores (ρ = 0.86, P < 0.01). Osteochondral allograft MRI scoring system was sensitive to differences in outcomes between the types of allografts. Conclusions: We have described a comprehensive MRI scoring system for osteochondral allografts and have validated this scoring system with histopathologic and µCT reference standards as well as biomechanical indentation testing. PMID:24489999

  4. Modeling the Object-Oriented Space Through Validated Measures

    NASA Technical Reports Server (NTRS)

    Neal, Ralph D.

    1996-01-01

    In order to truly understand software and the software development process, software measurement must be better understood. A beginning step toward a better understanding of software measurement is the categorization of the measurements by some meaningful taxonomy. The most meaningful taxonomy would capture the basic nature of the subject oriented (O-O) space. The interesting characteristics of object oriented software offer a starting point for such a categorization of measures. A taxonomy has been developed based on fourteen characteristics of object-oriented software gathered from the literature This taxonomy allows us to easily see gaps and redundancies in the O-O measures. The taxonomy also clearly differentiates among taxa so that there is no ambiguity as to the taxon to which a measure belongs. The taxonomy has been populated with thirty-two measures that have been validated in the narrow sense of Fenton, using measurement theory with Zuse's augmentation.

  5. Biomechanical models for radial distance determination by the rat vibrissal system.

    PubMed

    Birdwell, J Alexander; Solomon, Joseph H; Thajchayapong, Montakan; Taylor, Michael A; Cheely, Matthew; Towal, R Blythe; Conradt, Jorg; Hartmann, Mitra J Z

    2007-10-01

    Rats use active, rhythmic movements of their whiskers to acquire tactile information about three-dimensional object features. There are no receptors along the length of the whisker; therefore all tactile information must be mechanically transduced back to receptors at the whisker base. This raises the question: how might the rat determine the radial contact position of an object along the whisker? We developed two complementary biomechanical models that show that the rat could determine radial object distance by monitoring the rate of change of moment (or equivalently, the rate of change of curvature) at the whisker base. The first model is used to explore the effects of taper and inherent whisker curvature on whisker deformation and used to predict the shapes of real rat whiskers during deflections at different radial distances. Predicted shapes closely matched experimental measurements. The second model describes the relationship between radial object distance and the rate of change of moment at the base of a tapered, inherently curved whisker. Together, these models can account for recent recordings showing that some trigeminal ganglion (Vg) neurons encode closer radial distances with increased firing rates. The models also suggest that four and only four physical variables at the whisker base -- angular position, angular velocity, moment, and rate of change of moment -- are needed to describe the dynamic state of a whisker. We interpret these results in the context of our evolving hypothesis that neural responses in Vg can be represented using a state-encoding scheme that includes combinations of these four variables.

  6. Performance analysis in sport: contributions from a joint analysis of athletes' experience and biomechanical indicators.

    PubMed

    Sève, C; Nordez, A; Poizat, G; Saury, J

    2013-10-01

    The purpose of this study was to test the usefulness of combining two types of analysis to investigate sports performance with the aim of optimizing it. These two types of analysis correspond to two levels of athletes' activity: (a) their experiences during performance and (b) the biomechanical characteristics of their movements. Rowing served as an illustration, and the activity of one female crew member was studied during a race. Three types of data were collected: (a) audiovisual data recorded during the race; (b) verbalization data obtained in interviews conducted afterward; and (c) biomechanical data. The courses of experience of the two rowers during the race were reconstructed on the basis of the audiovisual and verbalization data. This paper presents a detailed analysis of a single phenomenon of the race experienced by one of the rowers. According to the coaches, it reflected a dysfunction in crew coordination. The aim of this analysis was to identify the biomechanical characteristics of the rowers' movements that might explain it. The results showed that the phenomenon could be explained principally by an amplitude differential between the two rowers' strokes. On this basis, the coaches defined new training objectives to remedy the dysfunction in crew coordination. © 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. The relationship between corneal biomechanics and anterior segment parameters in the early stage of orthokeratology: A pilot study.

    PubMed

    Chen, Renai; Mao, Xinjie; Jiang, Jun; Shen, Meixiao; Lian, Yan; Zhang, Bin; Lu, Fan

    2017-05-01

    To investigate the relationship between corneal biomechanics and anterior segment parameters in the early stage of overnight orthokeratology.Twenty-three eyes from 23 subjects were involved in the study. Corneal biomechanics, including corneal hysteresis (CH) and corneal resistance factor (CRF), and parameters of the anterior segment, including corneal curvature, central corneal thickness (CCT), and corneal sublayers' thickness, were measured at baseline and day 1 and 7 after wearing orthokeratology lens. One-way analysis of variance with repeated measures was used to compare the longitudinal changes and partial least squares linear regression was used to explore the relationship between corneal biomechanics and anterior segment parameters.At baseline, CH and CRF were positively correlated with CCT (r = 0.244, P = .008 for CH; r = 0.249, P < .001 for CRF), central stroma thickness (CST) (r = 0.241, P = .008 for CH; r = 0.244, P = .002 for CRF) and central Bowman layer thickness (CBT) (r = 0.138, P = .039 for CH; r = 0.171, P = .006 for CRF). Both CH and CRF significantly decreased from day 1 after orthokeratology. The corneal curvature and the epithelium thickness also significantly decreased, while the stromal layer thickened significantly from day 1 after orthokeratology. There was no correlation between the changes of corneal biomechanics and anterior segment parameters at day 1 and 7 after orthokeratology.While corneal biomechanics were positively correlated with CCT, CST, and CBT, the changes of CH and CRF were not correlated with the changes of corneal curvature, CCT, and corneal sublayers' thickness in the early stage of orthokeratology in our study.

  8. Speckle correlation method used to measure object's in-plane velocity.

    PubMed

    Smíd, Petr; Horváth, Pavel; Hrabovský, Miroslav

    2007-06-20

    We present a measurement of an object's in-plane velocity in one direction by the use of the speckle correlation method. Numerical correlations of speckle patterns recorded periodically during motion of the object under investigation give information used to evaluate the object's in-plane velocity. The proposed optical setup uses a detection plane in the image field and enables one to detect the object's velocity within the interval (10-150) microm x s(-1). Simulation analysis shows a way of controlling the measuring range. The presented theory, simulation analysis, and setup are verified through an experiment of measurement of the velocity profile of an object.

  9. A selection of biomechanical research problems: From modeling to experimentation

    NASA Astrophysics Data System (ADS)

    Abbasi, Cyrus Omid

    The research undertakings within this manuscript illustrate the importance of biomechanics in today's science. Without doubt, biomechanics can be utilized to obtain a better understanding of many unsolved mysteries involved in the field of medicine. Moreover, biomechanics can be used to develop better prosthetic or surgical devices as well. Chapter 2 represents a medical problem, which has not been solved for more than a century. With the use of fundamental principles of biomechanics', a better insight of this problem and its possible causes were obtained. Chapter 3 investigates the mechanical interaction between the human teeth and some processed food products during mastication, which is a routine but crucial daily activity of a human being. Chapter 4 looks at a problem within the field of surgery. In this chapter the stability and reliability of two different Suturing-Techniques are explored. Chapters 5 and 6 represent new patent designs as a result of the investigations made in Chapter 4. Chapter 7 studies the impact and load transfer patterns during the collision between a child's head and the ground. All of the above mentioned chapters show the significance of biomechanics in solving a range of different medical problems that involve physical and or mechanical characters.

  10. Biomechanical Outcomes After Bio-enhanced Anterior Cruciate Ligament Repair and Anterior Cruciate Ligament Reconstruction Are Equal in a Porcine Model

    PubMed Central

    Vavken, Patrick; Fleming, Braden C.; Mastrangelo, Ashley N.; Machan, Jason T.; Murray, Martha M.

    2011-01-01

    Purpose The objective of this study was to compare the biomechanical outcomes of a new method of anterior cruciate ligament (ACL) treatment, bio-enhanced ACL repair, with ACL reconstruction in a large animal model. Methods Twenty-four skeletally immature pigs underwent unilateral ACL transection and were randomly allocated to receive bio-enhanced ACL repair with a collagen-platelet composite, allograft (bone–patellar tendon– bone) reconstruction, or no further treatment (n = 8 for each group). The structural properties and anteroposterior laxity of the experimental and contralateral ACL-intact knees were measured 15 weeks postoperatively. All dependent variables were normalized to those of the contralateral knee and compared by use of generalized linear mixed models. Results After 15 weeks, bio-enhanced ACL repair and ACL reconstruction produced superior biomechanical outcomes to ACL transection. However, there were no significant differences between bio-enhanced ACL repair and ACL reconstruction for maximum load (P = .4745), maximum displacement (P = .4217), or linear stiffness (P = .6327). There were no significant differences between the 2 surgical techniques in anteroposterior laxity at 30° (P = .7947), 60° (P = .6270), or 90° (P = .9008). Conclusions Bio-enhanced ACL repair produced biomechanical results that were not different from ACL reconstruction in a skeletally immature, large animal model, although the variability associated with both procedures was large. Both procedures produced significantly improved results over ACL transection, showing that both were effective in this model. Clinical Relevance Bio-enhanced ACL repair may 1 day provide an alternative treatment option for ACL injury. PMID:22261137

  11. The short-term effects of running on the deformation of knee articular cartilage and its relationship to biomechanical loads at the knee.

    PubMed

    Boocock, M; McNair, P; Cicuttini, F; Stuart, A; Sinclair, T

    2009-07-01

    To investigate the short-term effects of recreational running on the deformation of knee articular cartilage and to examine the relationship between changes in knee cartilage volume and biomechanical modulators of knee joint load. Twenty healthy volunteers participated in a two phase cross-sectional study. Session 1 involved Magnetic Resonance Imaging (MRI) of femoral and tibial cartilage volumes prior to and following a 30 min period of relaxed sitting, which was directly followed by a recreational run of 5000 steps. Subsequently, all participants undertook a laboratory study of their running gait to compare biomechanical derived measures of knee joint loading with changes in cartilage volume. Estimates of knee joint load were determined using a rigid-link segment, dynamic biomechanical model of the lower limbs and a simplified muscle model. Running resulted in significant deformation of the medial (5.3%, P<0.01) and lateral femoral cartilage (4.0%, P<0.05) and lateral aspect of the tibial cartilage (5.7%, P<0.01), with no significant differences between genders. Maximum compression stress was significantly correlated with percentage changes in lateral femoral cartilage volume (r(2)=0.456, P<0.05). No other biomechanical variables correlated with volume changes. Limited evidence was found linking biomechanical measures of knee joint loading and observed short-term deformation of knee articular cartilage volume following running. Further enhancement of knee muscle modelling and analysis of stress distribution across cartilage are needed if we are to fully understand the contribution of biomechanical factors to knee joint loading and the pathogenesis of knee osteoarthritis (OA).

  12. Instrumented Footwear Inserts: A New Tool for Measuring Forces and Biomechanical State Changes During Dynamic Movements

    DTIC Science & Technology

    2017-03-03

    biomechanical gait state changes within prolonged exercise or training events. II. MATERIAL AND METHODS A. Instrumented Insert Design We developed a...beginning and end of each data collection trial using a user interface designed specifically for this purpose in MATLAB. F. Calibration Proces:Static...consisted of walking for several minutes indoors (thin carpeted surface on concrete) and outdoors on several different surfaces ( pavement , gravel and

  13. Biomechanical effects of valgus knee bracing: a systematic review and meta-analysis.

    PubMed

    Moyer, R F; Birmingham, T B; Bryant, D M; Giffin, J R; Marriott, K A; Leitch, K M

    2015-02-01

    To review and synthesize the biomechanical effects of valgus knee bracing for patients with medial knee osteoarthritis (OA). Electronic databases were searched from their inception to May 2014. Two reviewers independently determined study eligibility, rated study quality and extracted data. Where possible, data were combined into meta-analyses and pooled estimates with 95% confidence intervals (CI) for standardized mean differences (SMD) were calculated. Thirty studies were included with 478 subjects tested while using a valgus knee brace. Various biomechanical methods suggested valgus braces can decrease direct measures of medial knee compressive force, indirect measures representing the mediolateral distribution of load across the knee, quadriceps/hamstring and quadriceps/gastrocnemius co-contraction ratios, and increase medial joint space during gait. Meta-analysis from 17 studies suggested a statistically significant decrease in the external knee adduction moment (KAM) during walking, with a moderate-to-high effect size (SMD = 0.61; 95% CI: 0.39, 0.83; P < 0.001). Meta-regression identified a near-significant association for the KAM effect size and duration of brace use only (β, -0.01; 95% CI: -0.03, 0.0001; P = 0.06); with longer durations of brace use associated with smaller treatment effects. Minor complications were commonly reported during brace use and included slipping, discomfort and poor fit, blisters and skin irritation. Systematic review and meta-analysis suggests valgus knee braces can alter knee joint loads through a combination of mechanisms, with moderate-to-high effect sizes in biomechanical outcomes. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  14. Mechanical Characterisation and Biomechanical and Biological Behaviours of Ti-Zr Binary-Alloy Dental Implants

    PubMed Central

    Jiménez-Garrudo, Antonio; Gil-Mur, Francisco Javier; Manero, José María; Punset-Fuste, Miquel; Chávarri-Prado, David; Diéguez-Pereira, Markel; Monticelli, Francesca

    2017-01-01

    The objective of the study is to characterise the mechanical properties of Ti-15Zr binary alloy dental implants and to describe their biomechanical behaviour as well as their osseointegration capacity compared with the conventional Ti-6Al-4V (TAV) alloy implants. The mechanical properties of Ti-15Zr binary alloy were characterised using Roxolid© implants (Straumann, Basel, Switzerland) via ultrasound. Their biomechanical behaviour was described via finite element analysis. Their osseointegration capacity was compared via an in vivo study performed on 12 adult rabbits. Young's modulus of the Roxolid© implant was around 103 GPa, and the Poisson coefficient was around 0.33. There were no significant differences in terms of Von Mises stress values at the implant and bone level between both alloys. Regarding deformation, the highest value was observed for Ti-15Zr implant, and the lowest value was observed for the cortical bone surrounding TAV implant, with no deformation differences at the bone level between both alloys. Histological analysis of the implants inserted in rabbits demonstrated higher BIC percentage for Ti-15Zr implants at 3 and 6 weeks. Ti-15Zr alloy showed elastic properties and biomechanical behaviours similar to TAV alloy, although Ti-15Zr implant had a greater BIC percentage after 3 and 6 weeks of osseointegration. PMID:29318142

  15. Biomechanical aspects of lower limb torsional deformation correction with the Ilizarov external fixator.

    PubMed

    Morasiewicz, Piotr; Filipiak, Jarosław; Krysztoforski, Krzysztof; Dragan, Szymon

    2014-03-01

    The correction of torsional deformities with the Ilizarov apparatus is accompanied by rotational and translational displacement, which affects the biomechanics of the bone fragments. Understanding the biomechanical factors will assist in designing the optimal treatment strategy and mechanical properties of the fixator, thus shortening the duration of treatment and improving the outcomes. In order to determine the impact of different types of derotators on the kinematics of bone fragments in Ilizarov apparatus, physical models were studied. Translational and derotational displacement was measured using non-contact method (Optotrak Certus Motion Capture System). The results of the studies conducted on physical models have shown that regardless of the type of the derotator, the divergence between the applied angle of derotation and the obtained angle of rotation relative to fragments needs to be taken into account. Transverse displacement of fragments occur by 3.5 mm to approximately 9 mm, depending on the angle of derotation. For correction of rotational deformities up to 30°, it is advisable to use the type Z derotators because of its higher accuracy of derotation. Different types of derotators can affect the biomechanical conditions in the regenerating bone tissue through different kinematics characteristics.

  16. The Impact of Biomechanics in Tissue Engineering and Regenerative Medicine

    PubMed Central

    Butler, David L.; Goldstein, Steven A.; Guo, X. Edward; Kamm, Roger; Laurencin, Cato T.; McIntire, Larry V.; Mow, Van C.; Nerem, Robert M.; Sah, Robert L.; Soslowsky, Louis J.; Spilker, Robert L.; Tranquillo, Robert T.

    2009-01-01

    Biomechanical factors profoundly influence the processes of tissue growth, development, maintenance, degeneration, and repair. Regenerative strategies to restore damaged or diseased tissues in vivo and create living tissue replacements in vitro have recently begun to harness advances in understanding of how cells and tissues sense and adapt to their mechanical environment. It is clear that biomechanical considerations will be fundamental to the successful development of clinical therapies based on principles of tissue engineering and regenerative medicine for a broad range of musculoskeletal, cardiovascular, craniofacial, skin, urinary, and neural tissues. Biomechanical stimuli may in fact hold the key to producing regenerated tissues with high strength and endurance. However, many challenges remain, particularly for tissues that function within complex and demanding mechanical environments in vivo. This paper reviews the present role and potential impact of experimental and computational biomechanics in engineering functional tissues using several illustrative examples of past successes and future grand challenges. PMID:19583462

  17. The medical simulation markup language - simplifying the biomechanical modeling workflow.

    PubMed

    Suwelack, Stefan; Stoll, Markus; Schalck, Sebastian; Schoch, Nicolai; Dillmann, Rüdiger; Bendl, Rolf; Heuveline, Vincent; Speidel, Stefanie

    2014-01-01

    Modeling and simulation of the human body by means of continuum mechanics has become an important tool in diagnostics, computer-assisted interventions and training. This modeling approach seeks to construct patient-specific biomechanical models from tomographic data. Usually many different tools such as segmentation and meshing algorithms are involved in this workflow. In this paper we present a generalized and flexible description for biomechanical models. The unique feature of the new modeling language is that it not only describes the final biomechanical simulation, but also the workflow how the biomechanical model is constructed from tomographic data. In this way, the MSML can act as a middleware between all tools used in the modeling pipeline. The MSML thus greatly facilitates the prototyping of medical simulation workflows for clinical and research purposes. In this paper, we not only detail the XML-based modeling scheme, but also present a concrete implementation. Different examples highlight the flexibility, robustness and ease-of-use of the approach.

  18. Improving the Fitness of High-Dimensional Biomechanical Models via Data-Driven Stochastic Exploration

    PubMed Central

    Bustamante, Carlos D.; Valero-Cuevas, Francisco J.

    2010-01-01

    The field of complex biomechanical modeling has begun to rely on Monte Carlo techniques to investigate the effects of parameter variability and measurement uncertainty on model outputs, search for optimal parameter combinations, and define model limitations. However, advanced stochastic methods to perform data-driven explorations, such as Markov chain Monte Carlo (MCMC), become necessary as the number of model parameters increases. Here, we demonstrate the feasibility and, what to our knowledge is, the first use of an MCMC approach to improve the fitness of realistically large biomechanical models. We used a Metropolis–Hastings algorithm to search increasingly complex parameter landscapes (3, 8, 24, and 36 dimensions) to uncover underlying distributions of anatomical parameters of a “truth model” of the human thumb on the basis of simulated kinematic data (thumbnail location, orientation, and linear and angular velocities) polluted by zero-mean, uncorrelated multivariate Gaussian “measurement noise.” Driven by these data, ten Markov chains searched each model parameter space for the subspace that best fit the data (posterior distribution). As expected, the convergence time increased, more local minima were found, and marginal distributions broadened as the parameter space complexity increased. In the 36-D scenario, some chains found local minima but the majority of chains converged to the true posterior distribution (confirmed using a cross-validation dataset), thus demonstrating the feasibility and utility of these methods for realistically large biomechanical problems. PMID:19272906

  19. Energetics, Biomechanics, and Performance in Masters' Swimmers: A Systematic Review.

    PubMed

    Ferreira, Maria I; Barbosa, Tiago M; Costa, Mário J; Neiva, Henrique P; Marinho, Daniel A

    2016-07-01

    Ferreira, MI, Barbosa, TM, Costa, MJ, Neiva, HP, and Marinho, DA. Energetics, biomechanics, and performance in masters' swimmers: a systematic review. J Strength Cond Res 30(7): 2069-2081, 2016-This study aimed to summarize evidence on masters' swimmers energetics, biomechanics, and performance gathered in selected studies. An expanded search was conducted on 6 databases, conference proceedings, and department files. Fifteen studies were selected for further analysis. A qualitative evaluation of the studies based on the Quality Index (QI) was performed by 2 independent reviewers. The studies were thereafter classified into 3 domains according to the reported data: performance (10 studies), energetics (4 studies), and biomechanics (6 studies). The selected 15 articles included in this review presented low QI scores (mean score, 10.47 points). The biomechanics domain obtained higher QI (11.5 points), followed by energetics and performance (10.6 and 9.9 points, respectively). Stroke frequency (SF) and stroke length (SL) were both influenced by aging, although SF is more affected than SL. Propelling efficiency (ηp) decreased with age. Swimming performance declined with age. The performance declines with age having male swimmers deliver better performances than female counterparts, although this difference tends to be narrow in long-distance events. One single longitudinal study is found in the literature reporting the changes in performance over time. The remaining studies are cross-sectional designs focusing on the energetics and biomechanics. Overall, biomechanics parameters, such as SF, SL, and ηp, tend to decrease with age. This review shows the lack of a solid body of knowledge (reflected in the amount and quality of the articles published) on the changes in biomechanics, energetics, and performance of master swimmers over time. The training programs for this age-group should aim to preserve the energetics as much as possible and, concurrently, improve the

  20. Study on diagnosis of micro-biomechanical structure using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Saeki, Souichi; Hashimoto, Youhei; Saito, Takashi; Hiro, Takafumi; Matsuzaki, Masunori

    2007-02-01

    Acute coronary syndromes, e.g. myocardial infarctions, are caused by the rupture of unstable plaques on coronary arteries. The stability of plaque, which depends on biomechanical properties of fibrous cap, should be diagnosed crucially. Recently, Optical Coherence Tomography (OCT) has been developed as a cross-sectional imaging method of microstructural biological tissue with high resolution 1~10 μm. Multi-functional OCT system has been promising, e.g. an estimator of biomechanical characteristics. It has been, however, difficult to estimate biomechanical characteristics, because OCT images have just speckle patterns by back-scattering light from tissue. In this study, presented is Optical Coherence Straingraphy (OCS) on the basis of OCT system, which can diagnose tissue strain distribution. This is basically composed of Recursive Cross-correlation technique (RC), which can provide a displacement vector distribution with high resolution. Furthermore, Adjacent Cross-correlation Multiplication (ACM) is introduced as a speckle noise reduction method. Multiplying adjacent correlation maps can eliminate anomalies from speckle noise, and then can enhance S/N in the determination of maximum correlation coefficient. Error propagation also can be further prevented by introducing to the recursive algorithm (RC). In addition, the spatial vector interpolation by local least square method is introduced to remove erroneous vectors and smooth the vector distribution. This was numerically applied to compressed elastic heterogeneous tissue samples to carry out the accuracy verifications. Consequently, it was quantitatively confirmed that its accuracy of displacement vectors and strain matrix components could be enhanced, comparing with the conventional method. Therefore, the proposed method was validated by the identification of different elastic objects with having nearly high resolution for that defined by optical system.

  1. Weight-Bearing Dorsiflexion Range of Motion and Landing Biomechanics in Individuals With Chronic Ankle Instability

    PubMed Central

    Hoch, Matthew C.; Farwell, Kelley E.; Gaven, Stacey L.; Weinhandl, Joshua T.

    2015-01-01

    Context People with chronic ankle instability (CAI) exhibit less weight-bearing dorsiflexion range of motion (ROM) and less knee flexion during landing than people with stable ankles. Examining the relationship between dorsiflexion ROM and landing biomechanics may identify a modifiable factor associated with altered kinematics and kinetics during landing tasks. Objective To examine the relationship between weight-bearing dorsiflexion ROM and single-legged landing biomechanics in persons with CAI. Design Cross-sectional study. Setting Laboratory. Patients or Other Participants Fifteen physically active persons with CAI (5 men, 10 women; age = 21.9 ± 2.1 years, height = 168.7 ± 9.0 cm, mass = 69.4 ± 13.3 kg) participated. Intervention(s) Participants performed dorsiflexion ROM and single-legged landings from a 40-cm height. Sagittal-plane kinematics of the lower extremity and ground reaction forces (GRFs) were captured during landing. Main Outcome Measure(s) Static dorsiflexion was measured using the weight-bearing–lunge test. Kinematics of the ankle, knee, and hip were observed at initial contact, maximum angle, and sagittal displacement. Sagittal displacements of the ankle, knee, and hip were summed to examine overall sagittal displacement. Kinetic variables were maximum posterior and vertical GRFs normalized to body weight. We used Pearson product moment correlations to evaluate the relationships between dorsiflexion ROM and landing biomechanics. Correlations (r) were interpreted as weak (0.00–0.40), moderate (0.41–0.69), or strong (0.70–1.00). The coefficient of determination (r2) was used to determine the amount of explained variance among variables. Results Static dorsiflexion ROM was moderately correlated with maximum dorsiflexion (r = 0.49, r2 = 0.24), ankle displacement (r = 0.47, r2 = 0.22), and total displacement (r = 0.67, r2 = 0.45) during landing. Dorsiflexion ROM measured statically and during landing demonstrated moderate to strong

  2. Advanced Computational Methods in Bio-Mechanics.

    PubMed

    Al Qahtani, Waleed M S; El-Anwar, Mohamed I

    2018-04-15

    A novel partnership between surgeons and machines, made possible by advances in computing and engineering technology, could overcome many of the limitations of traditional surgery. By extending surgeons' ability to plan and carry out surgical interventions more accurately and with fewer traumas, computer-integrated surgery (CIS) systems could help to improve clinical outcomes and the efficiency of healthcare delivery. CIS systems could have a similar impact on surgery to that long since realised in computer-integrated manufacturing. Mathematical modelling and computer simulation have proved tremendously successful in engineering. Computational mechanics has enabled technological developments in virtually every area of our lives. One of the greatest challenges for mechanists is to extend the success of computational mechanics to fields outside traditional engineering, in particular to biology, the biomedical sciences, and medicine. Biomechanics has significant potential for applications in orthopaedic industry, and the performance arts since skills needed for these activities are visibly related to the human musculoskeletal and nervous systems. Although biomechanics is widely used nowadays in the orthopaedic industry to design orthopaedic implants for human joints, dental parts, external fixations and other medical purposes, numerous researches funded by billions of dollars are still running to build a new future for sports and human healthcare in what is called biomechanics era.

  3. Graft biomechanical properties after penetrating keratoplasty in keratoconus.

    PubMed

    Feizi, Sepehr; Einollahi, Bahram; Yazdani, Shahin; Hashemloo, Ali

    2012-08-01

    To measure corneal graft biomechanical properties after penetrating keratoplasty (PKP) in a group of keratoconic eyes using the ocular response analyzer (ORA) and to evaluate the relationship between donor size, donor-recipient disparity and central graft thickness (CGT), and ORA parameters. This cross-sectional study was conducted on 34 eyes of 34 keratoconus patients who had undergone PKP. Corneal hysteresis (CH), corneal resistance factor (CRF), and cornea-compensated intraocular pressure were measured at least 6 months after complete suture removal. Two groups of donor-recipient disparity (0.25 vs. 0.50 mm) were compared using the independent t test. Multivariate regression analysis was used to investigate the correlation of donor trephine size and CGT with ORA parameters. Factors influencing intraocular pressure measured with the Goldmann applanation tonometer (IOP GAT) after PKP were determined using multiple regression analysis. Mean patient age and follow-up period were 29.6 ± 6.2 years and 82.4 ± 59.6 months, respectively. Mean CGT, CH, and CRF were 564.7 ± 36.9 μm, 10.1 ± 2.1 mm Hg, and 10.0 ± 2.3 mm Hg, respectively. CH and CRF had a significant positive correlation with donor trephine size and CGT. Significantly greater values of CH and CRF were observed in the 0.5-mm disparity group compared with the 0.25-mm disparity group. Among the studied parameters, only CH, CRF, and cornea-compensated intraocular pressure had a significant positive correlation with IOP GAT. Graft biomechanics seem to be closer to normal values with larger grafts and greater donor-recipient disparity. These metrics had a significant correlation with IOP GAT after PKP.

  4. Learning object correspondences with the observed transport shape measure.

    PubMed

    Pitiot, Alain; Delingette, Hervé; Toga, Arthur W; Thompson, Paul M

    2003-07-01

    We propose a learning method which introduces explicit knowledge to the object correspondence problem. Our approach uses an a priori learning set to compute a dense correspondence field between two objects, where the characteristics of the field bear close resemblance to those in the learning set. We introduce a new local shape measure we call the "observed transport measure", whose properties make it particularly amenable to the matching problem. From the values of our measure obtained at every point of the objects to be matched, we compute a distance matrix which embeds the correspondence problem in a highly expressive and redundant construct and facilitates its manipulation. We present two learning strategies that rely on the distance matrix and discuss their applications to the matching of a variety of 1-D, 2-D and 3-D objects, including the corpus callosum and ventricular surfaces.

  5. A Biomechanical Modeling Guided CBCT Estimation Technique

    PubMed Central

    Zhang, You; Tehrani, Joubin Nasehi; Wang, Jing

    2017-01-01

    Two-dimensional-to-three-dimensional (2D-3D) deformation has emerged as a new technique to estimate cone-beam computed tomography (CBCT) images. The technique is based on deforming a prior high-quality 3D CT/CBCT image to form a new CBCT image, guided by limited-view 2D projections. The accuracy of this intensity-based technique, however, is often limited in low-contrast image regions with subtle intensity differences. The solved deformation vector fields (DVFs) can also be biomechanically unrealistic. To address these problems, we have developed a biomechanical modeling guided CBCT estimation technique (Bio-CBCT-est) by combining 2D-3D deformation with finite element analysis (FEA)-based biomechanical modeling of anatomical structures. Specifically, Bio-CBCT-est first extracts the 2D-3D deformation-generated displacement vectors at the high-contrast anatomical structure boundaries. The extracted surface deformation fields are subsequently used as the boundary conditions to drive structure-based FEA to correct and fine-tune the overall deformation fields, especially those at low-contrast regions within the structure. The resulting FEA-corrected deformation fields are then fed back into 2D-3D deformation to form an iterative loop, combining the benefits of intensity-based deformation and biomechanical modeling for CBCT estimation. Using eleven lung cancer patient cases, the accuracy of the Bio-CBCT-est technique has been compared to that of the 2D-3D deformation technique and the traditional CBCT reconstruction techniques. The accuracy was evaluated in the image domain, and also in the DVF domain through clinician-tracked lung landmarks. PMID:27831866

  6. Effects of Subsensory Noise and Fatigue on Knee Landing and Cross-over Cutting Biomechanics in Male Athletes.

    PubMed

    Qu, Xingda; Jiang, Jianxin; Hu, Xinyao

    2018-06-01

    The objective of this study was to examine the effects of subsensory noise and fatigue on knee biomechanics during the athletic task of landing followed by cross-over cutting. A total of 32 healthy male athletes participated in the study. They were evenly divided into 2 groups: no fatigue group and fatigue group. Fatigue was induced to the lower extremity by a repetitive squatting exercise in the fatigue group. Subsensory noise was generated by linear miniature vibrators bilaterally placed around the knee joints. During data collection, the participants were instructed to perform landing followed by cross-over cutting in both the subsensory on and off conditions. Dependent variables were selected to assess knee biomechanics in the phases of landing and cross-over cutting, separately. Results showed that fatigue resulted in larger knee flexion during landing and larger knee internal rotation during cross-over cutting. Subsensory noise was found to reduce knee rotation impulse during cross-over cutting. These findings suggest that cross-over cutting is more dangerous than landing in the fatigue condition, and subsensory noise may lead to changes in knee biomechanics consistent with reduced risk of anterior cruciate ligament injuries, but the changes may be task-specific.

  7. Biochemical and biomechanical characterisation of equine cervical facet joint cartilage.

    PubMed

    O'Leary, S A; White, J L; Hu, J C; Athanasiou, K A

    2018-04-15

    The equine cervical facet joint is a site of significant pathology. Located bilaterally on the dorsal spine, these diarthrodial joints work in conjunction with the intervertebral disc to facilitate appropriate spinal motion. Despite the high prevalence of pathology in this joint, the facet joint is understudied and thus lacking in viable treatment options. The goal of this study was to characterise equine facet joint cartilage and provide a comprehensive database describing the morphological, histological, biochemical and biomechanical properties of this tissue. Descriptive cadaver studies. A total of 132 facet joint surfaces were harvested from the cervical spines of six skeletally mature horses (11 surfaces per animal) for compiling biomechanical and biochemical properties of hyaline cartilage of the equine cervical facet joints. Gross morphometric measurements and histological staining were performed on facet joint cartilage. Creep indentation and uniaxial strain-to-failure testing were used to determine the biomechanical compressive and tensile properties. Biochemical assays included quantification of total collagen, sulfated glycosaminoglycan and DNA content. The facet joint surfaces were ovoid in shape with a flat articular surface. Histological analyses highlighted structures akin to articular cartilage of other synovial joints. In general, biomechanical and biochemical properties did not differ significantly between the inferior and superior joint surfaces as well as among spinal levels. Interestingly, compressive and tensile properties of cervical facet articular cartilage were lower than those of articular cartilage from other previously characterised equine joints. Removal of the superficial zone reduced the tissue's tensile strength, suggesting that this zone is important for the tensile integrity of the tissue. Facet surfaces were sampled at a single, central location and do not capture the potential topographic variation in cartilage properties. This

  8. Clinical applications of biomechanics cinematography.

    PubMed

    Woodle, A S

    1986-10-01

    Biomechanics cinematography is the analysis of movement of living organisms through the use of cameras, image projection systems, electronic digitizers, and computers. This article is a comparison of cinematographic systems and details practical uses of the modality in research and education.

  9. Dance band on the Titanic: biomechanical signaling in cardiac hypertrophy.

    PubMed

    Sussman, Mark A; McCulloch, Andrew; Borg, Thomas K

    2002-11-15

    Biomechanical signaling is a complex interaction of both intracellular and extracellular components. Both passive and active components are involved in the extracellular environment to signal through specific receptors to multiple signaling pathways. This review provides an overview of extracellular matrix, specific receptors, and signaling pathways for biomechanical stimulation in cardiac hypertrophy.

  10. Contributions to Objective Measurement and Evaluation of Trainee Competency.

    ERIC Educational Resources Information Center

    Moonan, William J.

    The purpose of this paper is to lay a basis for and discuss the components of a system, called COMET, designed to objectively measure and evaluate the competency of trainees in military training enterprises. COMET is an acronym for "Computerized Objective Measurement and Evaluation of Trainees." These goals will be accomplished by: (a)…

  11. Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    PubMed

    Girardi, Brandon L; Attia, Tarik; Backstein, David; Safir, Oleg; Willett, Thomas L; Kuzyk, Paul R T

    2016-02-29

    The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized composite models of the human pelvis for testing orthopaedic reconstruction techniques, few biomechanical comparisons of the properties of cadaveric and composite pelves exist. The aim of this study was to compare the mechanical properties of cadaveric pelves to those of the 4th generation composite model. An Instron ElectroPuls E10000 mechanical testing machine was used to load specimens with orientation, boundary conditions and degrees of freedom that approximated those occurring during the single legged phase of walking, including hip abductor force. Each specimen was instrumented with strain gauge rosettes. Overall specimen stiffness and principal strains were calculated from the test data. Composite specimens showed significantly higher overall stiffness and slightly less overall variability between specimens (composite K=1448±54N/m, cadaver K=832±62N/m; p<0.0001). Strains measured at specific sites in the composite models and cadavers were similar (but did differ) only when the applied load was scaled to overall construct stiffness. This finding regarding strain distribution and the difference in overall stiffness must be accounted for when using these composite models for biomechanics research. Altering the cortical wall thickness or tuning the elastic moduli of the composite material may improve future generations of the composite model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Biomechanics of metastatic disease in the vertebral column.

    PubMed

    Whyne, Cari M

    2014-06-01

    Metastatic disease in the vertebral column compromises the structural stability of the spine leading to increased risk of fracture. The complex patterns of osteolytic and osteoblastic disease within the bony spine have motivated a multimodal approach to better characterize the biomechanics of tumor-involved bone. This review presents our current understanding of the biomechanical behavior of metastatically involved vertebrae, and experimental and computational image-based approaches that have been employed to quantify structural integrity in preclinical models with translation to clinical data sets.

  13. Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests.

    PubMed

    Lee, Chian-Her; Hsu, Ching-Chi; Huang, Po-Yuang

    2017-08-01

    The pelvis is one of the most stressed areas of the human musculoskeletal system due to the transfer of truncal loads to the lower extremities. Sacroiliac joint injury may lead to abnormal joint mechanics and an unstable pelvis. Various fixation techniques have been evaluated and discussed. However, it may be difficult to investigate each technique due to variations in bone quality, bone anatomy, fracture pattern, and fixation location. Additionally, the finite element method is one useful technology that avoids these variations. Unfortunately, most previous studies neglected the effects of the lumbar spine and femurs when they investigated the biomechanics of pelvises. Thus, the aim of this study was to investigate the biomechanical performance of intact, injured, and treated pelvises using numerical and experimental approaches. Three-dimensional finite element models of the spine-pelvis-femur complex with and without muscles and ligaments were developed. The intact pelvis, the pelvis with sacroiliac joint injury, and three types of pelvic fixation techniques were analyzed. Concurrently, biomechanical tests were conducted to validate the numerical outcomes using artificial pelvises. Posterior iliosacral screw fixation showed relatively better fixation stability and lower risks of implant failure and pelvic breakage than sacral bar fixation and a locking compression plate fixation. The present study can help surgeons and engineers understand the biomechanics of intact, injured, and treated pelvises. Both the simulation technique and the experimental setup can be applied to investigate different pelvic injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Photogrammetric Measurements of Heritage Objects

    NASA Astrophysics Data System (ADS)

    Tumeliene, E.; Nareiko, V.; Suziedelyte Visockiene, J.

    2017-12-01

    Cultural heritage is an invaluable example of human culture and creativity. The majority of them can become unstable or can be destroyed due to a combination of human and natural disturbances. In order to restore, preserve, and systematize data about architectural heritage objects, it is necessary to have geodetic, photogrammetric measurements of such data and to constantly monitor condition of the objects. The data of immovable cultural objects for many years are stored in photogrammetric data archives. Such archives have Germany, Lithuania, England and other countries. The article gives a brief introduction of the history of data archives formation and presents a photogrammetric and modern methods of modelling the spatial geometric properties of objects currently used to reveal immovable cultural properties and to evaluate geometric sizes. The pilot work was done with the Concept Capture simulation program that was developed by the Bentley company with photos of the Blessed Virgin Mary painting in Pivašiūnai of Trakai district. A shot from the ground with 12.4 MP resolution Pentax K-x camera was done using lenses with different focal lengths. The painting of the Blessed Virgin Mary is coordinated by 4 reference geodesic points and therefore after the modelling work it was possible to evaluate the accuracy of the created model. Based on the results of the spatial (3D) model, photo shooting and modelling recommendations are presented, the advantages of the new technology are distinguished.

  15. An Exploration of the Perception of Dance and Its Relation to Biomechanical Motion: A Systematic Review and Narrative Synthesis.

    PubMed

    Chang, Michael; Halaki, Mark; Adams, Roger; Cobley, Stephen; Lee, Kwee-Yum; O'Dwyer, Nicholas

    2016-01-01

    In dance, the goals of actions are not always clearly defined. Investigations into the perceived quality of dance actions and their relation to biomechanical motion should give insight into the performance of dance actions and their goals. The purpose of this review was to explore and document current literature concerning dance perception and its relation to the biomechanics of motion. Seven studies were included in the review. The study results showed systematic differences between expert, non-expert, and novice dancers in biomechanical and perceptual measures, both of which also varied according to the actions expressed in dance. Biomechanical and perceptual variables were found to be correlated in all the studies in the review. Significant relations were observed between kinematic variables such as amplitude, speed, and variability of movement, and perceptual measures of beauty and performance quality. However, in general, there were no clear trends in these relations. Instead, the evidence suggests that perceptual ratings of dance may be specific to both the task (the skill of the particular action) and the context (the music and staging). The results also suggest that the human perceptual system is sensitive to skillful movements and neuromuscular coordination. Since the value perceived by audiences appears to be related to dance action goals and the coordination of dance elements, practitioners could place a priority on development and execution of those factors.

  16. Biomechanics, Exercise Physiology, and the 75th Anniversary of RQES

    ERIC Educational Resources Information Center

    Hamill, Joseph; Haymes, Emily M.

    2005-01-01

    The purpose of this paper is to review the biomechanics and exercise physiology studies published in the Research Quarterly for Exercise and Sport (RQES) over the past 75 years. Studies in biomechanics, a relatively new subdiscipline that evolved from kinesiology, first appeared in the journal about 40 years ago. Exercise physiology studies have…

  17. ASUPT Automated Objective Performance Measurement System.

    ERIC Educational Resources Information Center

    Waag, Wayne L.; And Others

    To realize its full research potential, a need exists for the development of an automated objective pilot performance evaluation system for use in the Advanced Simulation in Undergraduate Pilot Training (ASUPT) facility. The present report documents the approach taken for the development of performance measures and also presents data collected…

  18. The effect of ankle bracing on lower extremity biomechanics during landing: A systematic review.

    PubMed

    Mason-Mackay, A R; Whatman, C; Reid, D

    2016-07-01

    To examine the evidence for effect of ankle bracing on lower-extremity landing biomechanics. Literature review. Systematic search of the literature on EBSCO health databases. Articles critiqued by two reviewers. Ten studies were identified which investigated the effect of ankle bracing on landing biomechanics. Overall results suggest that landing biomechanics are altered with some brace types but studies disagree as to the particular variables affected. There is evidence that ankle bracing may alter lower-extremity landing biomechanics in a manner which predisposes athletes to injury. The focus of studies on specific biomechanical variables rather than biomechanical patterns, analysis of pooled data means in the presence of differing landing styles between participants, variation in landing-tasks investigated in different studies, and lack of studies investigating goal-directed sport-specific landing tasks creates difficulty in interpreting results. These areas require further research. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis

    PubMed Central

    Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil

    2012-01-01

    Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869

  20. Documenting progress: hand therapy treatment shift from biomechanical to occupational adaptation.

    PubMed

    Jack, Jada; Estes, Rebecca I

    2010-01-01

    The investment of time and self to develop therapeutic relationships with clients appears incongruent with today's time-constrained health care system, yet bridging the gap of these incongruencies is the challenge therapists face to provide high-quality, client-centered, occupation-based treatment. This case report illustrates a shift in approach from biomechanical to occupational adaptation (OA) in an orthopedic outpatient clinic. The progress of a client with lupus-related arthritis who was 6 days postsurgery is documented. The intervention initially used a biomechanical frame of reference, but when little progress had been made at 10 weeks after surgery, a shift was made to the more client-centered OA approach. The Canadian Occupational Performance Measure was administered, and an OA approach was initiated. On reassessment, clinically important improvements were documented in all functional tasks addressed. An OA approach provides the bridge between the application of clinical expertise, client-centered, occupation-based therapy and the time constraints placed by payer sources.

  1. Pregnancy- and delivery-induced biomechanical changes in rat vagina persist postpartum

    PubMed Central

    Alperin, Marianna; Feola, Andrew; Duerr, Robert; Moalli, Pamela; Abramowitch, Steven

    2010-01-01

    Introduction and hypothesis We sought to define changes in vaginal distensibility (VD) induced by pregnancy and vaginal delivery using a novel in vivo biomechanical testing protocol. Methods Under sedation, a balloon was inserted into the vagina of 27 virgin, pregnant and 4-week postpartum Long–Evans rats and incrementally distended. Pressure–volume curves were generated with slopes characterizing VD (higher slope = less distensible). One-way ANOVA with a Bonferroni post-hoc test were used for statistical analyses. Results Mean pressures at an infusion volume of 1 cc were lower in pregnant and postpartum rats than in virgins (P<0.001). VD was increased in pregnant vs. virgin rats (P<0.001) and did not recover to virgin levels post partum (P<0.001). Conclusions We have developed a test that measures VD in vivo under clinically relevant loading conditions. The increased VD in the late postpartum period defines a persistent change in biomechanical behavior of the vagina related to pregnancy and vaginal delivery. PMID:20424824

  2. Deriving injury risk curves using survival analysis from biomechanical experiments.

    PubMed

    Yoganandan, Narayan; Banerjee, Anjishnu; Hsu, Fang-Chi; Bass, Cameron R; Voo, Liming; Pintar, Frank A; Gayzik, F Scott

    2016-10-03

    Injury risk curves from biomechanical experimental data analysis are used in automotive studies to improve crashworthiness and advance occupant safety. Metrics such as acceleration and deflection coupled with outcomes such as fractures and anatomical disruptions from impact tests are used in simple binary regression models. As an improvement, the International Standards Organization suggested a different approach. It was based on survival analysis. While probability curves for side-impact-induced thorax and abdominal injuries and frontal impact-induced foot-ankle-leg injuries are developed using this approach, deficiencies are apparent. The objective of this study is to present an improved, robust and generalizable methodology in an attempt to resolve these issues. It includes: (a) statistical identification of the most appropriate independent variable (metric) from a pool of candidate metrics, measured and or derived during experimentation and analysis processes, based on the highest area under the receiver operator curve, (b) quantitative determination of the most optimal probability distribution based on the lowest Akaike information criterion, (c) supplementing the qualitative/visual inspection method for comparing the selected distribution with a non-parametric distribution with objective measures, (d) identification of overly influential observations using different methods, and (e) estimation of confidence intervals using techniques more appropriate to the underlying survival statistical model. These clear and quantified details can be easily implemented with commercial/open source packages. They can be used in retrospective analysis and prospective design of experiments, and in applications to different loading scenarios such as underbody blast events. The feasibility of the methodology is demonstrated using post mortem human subject experiments and 24 metrics associated with thoracic/abdominal injuries in side-impacts. Published by Elsevier Ltd.

  3. Advances in Proximal Interphalangeal Joint Arthroplasty: Biomechanics and Biomaterials.

    PubMed

    Zhu, Andy F; Rahgozar, Paymon; Chung, Kevin C

    2018-05-01

    Proximal interphalangeal (PIP) joint arthritis is a debilitating condition. The complexity of the joint makes management particularly challenging. Treatment of PIP arthritis requires an understanding of the biomechanics of the joint. PIP joint arthroplasty is one treatment option that has evolved over time. Advances in biomaterials have improved and expanded arthroplasty design. This article reviews biomechanics and arthroplasty design of the PIP joint. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Harnessing biomechanics to develop cartilage regeneration strategies.

    PubMed

    Athanasiou, Kyriacos A; Responte, Donald J; Brown, Wendy E; Hu, Jerry C

    2015-02-01

    As this review was prepared specifically for the American Society of Mechanical Engineers H.R. Lissner Medal, it primarily discusses work toward cartilage regeneration performed in Dr. Kyriacos A. Athanasiou's laboratory over the past 25 years. The prevalence and severity of degeneration of articular cartilage, a tissue whose main function is largely biomechanical, have motivated the development of cartilage tissue engineering approaches informed by biomechanics. This article provides a review of important steps toward regeneration of articular cartilage with suitable biomechanical properties. As a first step, biomechanical and biochemical characterization studies at the tissue level were used to provide design criteria for engineering neotissues. Extending this work to the single cell and subcellular levels has helped to develop biochemical and mechanical stimuli for tissue engineering studies. This strong mechanobiological foundation guided studies on regenerating hyaline articular cartilage, the knee meniscus, and temporomandibular joint (TMJ) fibrocartilage. Initial tissue engineering efforts centered on developing biodegradable scaffolds for cartilage regeneration. After many years of studying scaffold-based cartilage engineering, scaffoldless approaches were developed to address deficiencies of scaffold-based systems, resulting in the self-assembling process. This process was further improved by employing exogenous stimuli, such as hydrostatic pressure, growth factors, and matrix-modifying and catabolic agents, both singly and in synergistic combination to enhance neocartilage functional properties. Due to the high cell needs for tissue engineering and the limited supply of native articular chondrocytes, costochondral cells are emerging as a suitable cell source. Looking forward, additional cell sources are investigated to render these technologies more translatable. For example, dermis isolated adult stem (DIAS) cells show potential as a source of

  5. Analysis of Big Data in Gait Biomechanics: Current Trends and Future Directions.

    PubMed

    Phinyomark, Angkoon; Petri, Giovanni; Ibáñez-Marcelo, Esther; Osis, Sean T; Ferber, Reed

    2018-01-01

    The increasing amount of data in biomechanics research has greatly increased the importance of developing advanced multivariate analysis and machine learning techniques, which are better able to handle "big data". Consequently, advances in data science methods will expand the knowledge for testing new hypotheses about biomechanical risk factors associated with walking and running gait-related musculoskeletal injury. This paper begins with a brief introduction to an automated three-dimensional (3D) biomechanical gait data collection system: 3D GAIT, followed by how the studies in the field of gait biomechanics fit the quantities in the 5 V's definition of big data: volume, velocity, variety, veracity, and value. Next, we provide a review of recent research and development in multivariate and machine learning methods-based gait analysis that can be applied to big data analytics. These modern biomechanical gait analysis methods include several main modules such as initial input features, dimensionality reduction (feature selection and extraction), and learning algorithms (classification and clustering). Finally, a promising big data exploration tool called "topological data analysis" and directions for future research are outlined and discussed.

  6. Objective measures of situation awareness in a simulated medical environment

    PubMed Central

    Wright, M; Taekman, J; Endsley, M

    2004-01-01

    One major limitation in the use of human patient simulators is a lack of objective, validated measures of human performance. Objective measures are necessary if simulators are to be used to evaluate the skills and training of medical practitioners and teams or to evaluate the impact of new processes or equipment design on overall system performance. Situation awareness (SA) refers to a person's perception and understanding of their dynamic environment. This awareness and comprehension is critical in making correct decisions that ultimately lead to correct actions in medical care settings. An objective measure of SA may be more sensitive and diagnostic than traditional performance measures. This paper reviews a theory of SA and discusses the methods required for developing an objective measure of SA within the context of a simulated medical environment. Analysis and interpretation of SA data for both individual and team performance in health care are also presented. PMID:15465958

  7. Biomechanical effects of trees on soil and regolith: beyond treethrow

    Treesearch

    Jonathan D. Phillips; Daniel A. Marion

    2006-01-01

    Forest soils are profoundly influenced by the biomechanical as well as the chemical and biological effects of trees. Studies of biomechanical impacts have focused mainly on uprooting (treethrow), but this study shows that at least two other effects are significant: physical displacement of soil by root growth, and infilling of stump rot pits. Rocky soils in the...

  8. Measurements Conducted on an Unknown Object Labeled Pu-239

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoteling, Nathan

    Measurements were carried out on 12 November 2013 to determine whether Pu-239 was present on an object discovered in a plastic bag with label “Pu-­239 6 uCi.” Following initial survey measurements to verify that the object was not leaking or contaminated, spectra were collected with a High Purity Germanium (HPGe) detector with object positioned in two different configurations. Analysis of the spectra did not yield any direct evidence of Pu-­239. From the measured spectra, minimum detectable activity (MDA) was determined to be approximately 2 uCi for the gamma-­ray measurements. Although there was no direct evidence of Pu-239, a peak atmore » 60 keV characteristic of Am-­241 decay was observed. Since it is very likely that Am-­241 would be present in aged plutonium samples, this was interpreted as indirect evidence for the presence of plutonium on the object. Analysis of this peak led to an estimated Pu-­239 activity of 0.02–0.04 uCi, or <1x10 -6 grams.« less

  9. Morphological and biomechanical response to eutrophication and hydrodynamic stresses.

    PubMed

    Zhu, Guorong; Yuan, Changbo; Di, Guilan; Zhang, Meng; Ni, Leyi; Cao, Te; Fang, Rongting; Wu, Gongguo

    2018-05-01

    Eutrophication and hydrodynamics determine the final distribution patterns of aquatic macrophytes; however, there is limited available knowledge regarding their interactive effects. Morphological and biomechanical responses to eutrophication and hydrodynamic stresses were assessed by sampling five abundant and dominant species, Potamogeton maackianus, P. pectinatus, P. lucens, Ceratophyllum demersum and Myriophyllum spicatum, in three macrophyte beds in Lake Erhai, Yunnan Province, China: one exposed to eutrophication and moderate southeast (SE) wind; one with mesotrophication, but sheltered by the lakeshore, with weak wind disturbance; and one with meso-eutrophication and strong SE wind. The results showed significant interactive effects of eutrophication and hydrodynamics on most biomechanical traits and some morphological traits, suggesting that aquatic macrophytes preferentially undergo biomechanical adjustments to resist the coexisting eutrophication and hydrodynamic stresses. In particular, hydrodynamics increased both the tensile force and tensile strain of P. maackianus under meso-eutrophication and dramatically decreased them in eutrophic areas, suggesting that eutrophication triggers mechanical failure in this species. Additionally, P. pectinatus, C. demersum and M. spicatum showed the lowest and highest values for the biomechanical variables (greater values for M. spicatum) in the most eutrophic and hydrodynamic areas, respectively, implying that increases in hydrodynamics primarily induce mechanical damage in eutrophic species. The plants generally exhibited greater tensile strain in both shallow and deep waters and the greatest tensile force at moderate depths. The stem cross-sectional area, plant height, stem length, internode length, and branch traits were all responsible for determining the biomechanical variables. This study reveals that hydrodynamic changes primarily induce mechanical damage in eutrophic species, whereas eutrophication triggers

  10. Application of acoustic microscopy to assessment of cardiovascular biomechanics

    NASA Astrophysics Data System (ADS)

    Saijo, Yoshifumi; Sasaki, Hidehiko; Nitta, Shin-ichi; Tanaka, Motonao; Joergensen, Claus S.; Falk, Erling

    2002-11-01

    Acoustic microscopy provides information on physical and mechanical properties of biological tissues, while optical microscopy with various staining techniques provides chemical properties. The biomechanics of tissues is especially important in cardiovascular system because its pathophysiology is closely related with mechanical stresses such as blood pressure or blood flow. A scanning acoustic microscope (SAM) system with tone-burst ultrasound in the frequency range of 100-200 MHz has been developed, and attenuation and sound speed of tissues have been measured. In human coronary arteries, attenuation and sound speed were high in calcification and collagen, while both values were low in smooth muscle and lipid. Another SAM system with 800-MHz-1.3-GHz ultrasound was applied for aortas of Apo-E deficient mouse, which is known to develop atherosclerosis. Attenuation of ultrasound was significantly higher in type 1 collagen compared to type 3 collagen. Recently, a new type FFT-SAM using a single-pulse, broadband frequency range ultrasound (20-150 MHz) has been developed. Cardiac allograft was observed by FFT-SAM and the acoustic properties were able to grade allograft rejection. SAM provides very useful information for assessing cardiovascular biomechanics and for understanding normal and abnormal images of clinical ultrasound.

  11. Measuring the Speed of Newborn Object Recognition in Controlled Visual Worlds

    ERIC Educational Resources Information Center

    Wood, Justin N.; Wood, Samantha M. W.

    2017-01-01

    How long does it take for a newborn to recognize an object? Adults can recognize objects rapidly, but measuring object recognition speed in newborns has not previously been possible. Here we introduce an automated controlled-rearing method for measuring the speed of newborn object recognition in controlled visual worlds. We raised newborn chicks…

  12. Tennis elbow: a biomechanical and therapeutic approach.

    PubMed

    Schnatz, P; Steiner, C

    1993-07-01

    Lateral epicondylitis, one of the most common lesions of the arm, affects some 50% of tennis players. This condition poses a problem in clinical management because treatment is dependent not only on proper medical therapy but also on correction of the improper on-court biomechanics. The most common flaw is a late contact on the backhand groundstroke, forcing the player to extend the wrist with the extensor muscles. This action predisposes to trauma of the tendon fibers at the lateral epicondyle. Understanding the biomechanics will better prepare the physician to advise the patient and to communicate with a tennis teaching professional to facilitate long-term relief.

  13. Effects of a capacitive-resistive electric transfer therapy on physiological and biomechanical parameters in recreational runners: A randomized controlled crossover trial.

    PubMed

    Duñabeitia, Iratxe; Arrieta, Haritz; Torres-Unda, Jon; Gil, Javier; Santos-Concejero, Jordan; Gil, Susana M; Irazusta, Jon; Bidaurrazaga-Letona, Iraia

    2018-05-26

    This study compared the effects of a capacitive-resistive electric transfer therapy (Tecar) and passive rest on physiological and biomechanical parameters in recreational runners when performed shortly after an exhausting training session. Randomized controlled crossover trial. University biomechanical research laboratory. Fourteen trained male runners MAIN OUTCOME MEASURES: Physiological (running economy, oxygen uptake, respiratory exchange ratio, ventilation, heart rate, blood lactate concentration) and biomechanical (step length; stride angle, height, frequency, and contact time; swing time; contact phase; support phase; push-off phase) parameters were measured during two incremental treadmill running tests performed two days apart after an exhaustive training session. When running at 14 km/h and 16 km/h, the Tecar treatment group presented greater increases in stride length (p < 0.001), angle (p < 0.05) and height (p < 0.001) between the first and second tests than the control group and, accordingly, greater decreases in stride frequency (p < 0.05). Physiological parameters were similar between groups. The present study suggests that a Tecar therapy intervention enhances biomechanical parameters in recreational runners after an exhaustive training session more than passive rest, generating a more efficient running pattern without affecting selected physiological parameters. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. How to Assess the Biomechanical Risk Levels in Beekeeping.

    PubMed

    Maina, G; Rossi, F; Baracco, A

    2016-01-01

    Beekeepers are at particular risk of developing work-related musculoskeletal disorders, but many of the studies lack detailed exposure assessment. To evaluate the biomechanical overload exposure in a specific farming activity, a multitasking model has been developed through the characterization of 37 basic operational tasks typical of the beekeeping activity. The Occupational Repetitive Actions (OCRA) Checklist and the National Institute for Occupational Safety and Health (NIOSH) Lifting Index methodologies have been applied to these elementary tasks to evaluate the exposure, and the resulting risk indices have been time-weighted averaged. Finally, an easy access, computer-assisted toolkit has been developed to help the beekeepers in the biomechanical risk assessment process. The risk of biomechanical overload for the upper limbs ranges from acceptable (maintenance and recovery of woody material and honey packaging with dosing machine tasks) to high (distribution of the top supers) risk level. The risk for back injury is always borderline in women and increases with exposure time, whereas it ranges from acceptable to borderline in men. The definition of the biomechanical risk levels allows for planning of corrective actions aimed at preventing and reducing the risk of musculoskeletal disorders through engineering, administrative, and behavioral interventions. The methodology can be used for risk assessment in other mainly manual agricultural activities.

  15. Low-Back Biomechanics and Static Stability During Isometric Pushing

    PubMed Central

    Granata, Kevin P.; Bennett, Bradford C.

    2006-01-01

    Pushing and pulling tasks are increasingly prevalent in industrial workplaces. Few studies have investigated low-back biomechanical risk factors associated with pushing, and we are aware of none that has quantified spinal stability during pushing exertions. Data recorded from 11 healthy participants performing isometric pushing exertions demonstrated that trunk posture, vector force direction of the applied load, and trunk moment were influenced (p < .01) by exertion level, elevation of the handle for the pushing task, and foot position. A biomechanical model was used to analyze the posture and hand force data gathered from the pushing exertions. Model results indicate that pushing exertions provide significantly (p < .01) less stability than lifting when antagonistic cocontraction is ignored. However, stability can be augmented by recruitment of muscle cocontraction. Results suggest that cocontraction may be recruited to compensate for the fact that equilibrium mechanics provide little intrinsic trunk stiffness and stability during pushing exertions. If one maintains stability by means of cocontraction, additional spinal load is thereby created, increasing the risk of overload injury. Thus it is important to consider muscle cocontraction when evaluating the biomechanics of pushing exertions. Potential applications of this research include improved assessment of biomechanical risk factors for the design of industrial pushing tasks. PMID:16435695

  16. The biomechanics of leg ulceration.

    PubMed Central

    Chant, A.

    1999-01-01

    Research performed in the late 1960s, using 24Na, suggested that the perfusion of skin and subcutaneous tissues is critically dependent on the relationship between capillary (Pc) and tissue pressures (Pt). Perfusion changes differed significantly between controls and patients with venous disease and the differences could be interpreted as evidence that Pt remained high in venous diseased patients. From this starting point, a biomechanical theory for the aetiology of venous ulceration was developed and tested by measuring skin elasticity, limb cross-sectional area and laser Doppler flux. The results confirm that, modelled as a two-compartment system (vascular and interstitial fluid), forces can be demonstrated sufficient to cause intermittent capillary closure and subsequent reperfusion injury. These forces are maximal in the gaiter area, the site of most leg ulcers. Images Figure 2 Figure 4 PMID:10364960

  17. Vision for action and perception elicit dissociable adherence to Weber's law across a range of 'graspable' target objects.

    PubMed

    Heath, Matthew; Manzone, Joseph; Khan, Michaela; Davarpanah Jazi, Shirin

    2017-10-01

    A number of studies have reported that grasps and manual estimations of differently sized target objects (e.g., 20 through 70 mm) violate and adhere to Weber's law, respectively (e.g., Ganel et al. 2008a, Curr Biol 18:R599-R601)-a result interpreted as evidence that separate visual codes support actions (i.e., absolute) and perceptions (i.e., relative). More recent work employing a broader range of target objects (i.e., 5 through 120 mm) has laid question to this claim and proposed that grasps for 'larger' target objects (i.e., >20 mm) elicit an inverse relationship to Weber's law and that manual estimations for target objects greater than 40 mm violate the law (Bruno et al. 2016, Neuropsychologia 91:327-334). In accounting for this finding, it was proposed that biomechanical limits in aperture shaping preclude the application of Weber's law for larger target objects. It is, however, important to note that the work supporting a biomechanical account may have employed target objects that approached -or were beyond-some participants' maximal aperture separation. The present investigation examined whether grasps and manual estimations differentially adhere to Weber's law across a continuous range of functionally 'graspable' target objects (i.e., 10,…,80% of participant-specific maximal aperture separation). In addition, we employed a method of adjustment task to examine whether manual estimation provides a valid proxy for a traditional measure of perceptual judgment. Manual estimation and method of adjustment tasks demonstrated adherence to Weber's law across the continuous range of target objects used here, whereas grasps violated the law. Thus, results evince that grasps and manual estimations of graspable target objects are, respectively, mediated via absolute and relative visual information.

  18. Plantar Fasciitis and the Windlass Mechanism: A Biomechanical Link to Clinical Practice

    PubMed Central

    Malone, Terry R.

    2004-01-01

    Objective: Plantar fasciitis is a prevalent problem, with limited consensus among clinicians regarding the most effective treatment. The purpose of this literature review is to provide a systematic approach to the treatment of plantar fasciitis based on the windlass mechanism model. Data Sources: We searched MEDLINE, SPORT Discus, and CINAHL from 1966 to 2003 using the key words plantar fasciitis, windlass mechanism, pronation, heel pain, and heel spur. Data Synthesis: We offer a biomechanical application for the evaluation and treatment of plantar fasciitis based on a review of the literature for the windlass mechanism model. This model provides a means for describing plantar fasciitis conditions such that clinicians can formulate a potential causal relationship between the conditions and their treatments. Conclusions/Recommendations: Clinicians' understanding of the biomechanical causes of plantar fasciitis should guide the decision-making process concerning the evaluation and treatment of heel pain. Use of this approach may improve clinical outcomes because intervention does not merely treat physical symptoms but actively addresses the influences that resulted in the condition. Principles from this approach might also provide a basis for future research investigating the efficacy of plantar fascia treatment. PMID:16558682

  19. Biomechanical Analyses of Stair-climbing while Dual-tasking

    PubMed Central

    Vallabhajosula, Srikant; Tan, Chi Wei; Mukherjee, Mukul; Davidson, Austin J.; Stergiou, Nicholas

    2015-01-01

    Stair-climbing while doing a concurrent task like talking or holding an object is a common activity of daily living which poses high risk for falls. While biomechanical analyses of overground walking during dual-tasking have been studied extensively, little is known on the biomechanics of stair-climbing while dual-tasking. We sought to determine the impact of performing a concurrent cognitive or motor task during stair-climbing. We hypothesized that a concurrent cognitive task will have a greater impact on stair climbing performance compared to a concurrent motor task and that this impact will be greater on a higher-level step. Ten healthy young adults performed 10 trials of stair-climbing each under four conditions: stair ascending only, stair ascending and performing subtraction of serial sevens from a three-digit number, stair ascending and carrying an empty opaque box and stair ascending, performing subtraction of serial sevens from a random three-digit number and carrying an empty opaque box. Kinematics (lower extremity joint angles and minimum toe clearance) and kinetics (ground reaction forces and joint moments and powers) data were collected. We found that a concurrent cognitive task impacted kinetics but not kinematics of stair-climbing. The effect of dual-tasking during stair ascent also seemed to vary based on the different phases of stair ascent stance and seem to have greater impact as one climbs higher. Overall, the results of the current study suggest that the association between the executive functioning and motor task (like gait) becomes stronger as the level of complexity of the motor task increases. PMID:25773590

  20. Objectively measured sedentary time and academic achievement in schoolchildren.

    PubMed

    Lopes, Luís; Santos, Rute; Mota, Jorge; Pereira, Beatriz; Lopes, Vítor

    2017-03-01

    This study aimed to evaluate the relationship between objectively measured total sedentary time and academic achievement (AA) in Portuguese children. The sample comprised of 213 children (51.6% girls) aged 9.46 ± 0.43 years, from the north of Portugal. Sedentary time was measured with accelerometry, and AA was assessed using the Portuguese Language and Mathematics National Exams results. Multilevel linear regression models were fitted to assess regression coefficients predicting AA. The results showed that objectively measured total sedentary time was not associated with AA, after adjusting for potential confounders.

  1. Acoustic Measurement Of Periodic Motion Of Levitated Object

    NASA Technical Reports Server (NTRS)

    Watkins, John L.; Barmatz, Martin B.

    1992-01-01

    Some internal vibrations, oscillations in position, and rotations of acoustically levitated object measured by use of microphone already installed in typical levitation chamber for tuning chamber to resonance and monitoring operation. Levitating acoustic signal modulated by object motion of lower frequency. Amplitude modulation detected and analyzed spectrally to determine amplitudes and frequencies of motions.

  2. The effects of floor incline on lower extremity biomechanics during unilateral landing from a jump in dancers.

    PubMed

    Pappas, Evangelos; Orishimo, Karl F; Kremenic, Ian; Liederbach, Marijeanne; Hagins, Marshall

    2012-05-01

    Retrospective studies have suggested that dancers performing on inclined ("raked") stages have increased injury risk. One study suggests that biomechanical differences exist between flat and inclined surfaces during bilateral landings; however, no studies have examined whether such differences exist during unilateral landings. In addition, little is known regarding potential gender differences in landing mechanics of dancers. Professional dancers (N = 41; 14 male, 27 female) performed unilateral drop jumps from a 30 cm platform onto flat and inclined surfaces while extremity joint angles and moments were identified and analyzed. There were significant joint angle and moment effects due to the inclined flooring. Women had significantly decreased peak ankle dorsiflexion and hip adduction moment compared with men. Findings of the current study suggest that unilateral landings on inclined stages create measurable changes in lower extremity biomechanical variables. These findings provide a preliminary biomechanical rationale for differences in injury rates found in observational studies of raked stages.

  3. Knee joint biomechanics and neuromuscular control during gait before and after total knee arthroplasty are sex-specific.

    PubMed

    Astephen Wilson, Janie L; Dunbar, Michael J; Hubley-Kozey, Cheryl L

    2015-01-01

    The future of total knee arthroplasty (TKA) surgery will involve planning that incorporates more patient-specific characteristics. Despite known biological, morphological, and functional differences between men and women, there has been little investigation into knee joint biomechanical and neuromuscular differences between men and women with osteoarthritis, and none that have examined sex-specific biomechanical and neuromuscular responses to TKA surgery. The objective of this study was to examine sex-associated differences in knee kinematics, kinetics and neuromuscular patterns during gait before and after TKA. Fifty-two patients with end-stage knee OA (28 women, 24 men) underwent gait and neuromuscular analysis within the week prior to and one year after surgery. A number of sex-specific differences were identified which suggest a different manifestation of end-stage knee OA between the sexes. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Objectively measured physical activity and 12-month trajectories of neck-shoulder pain in workers: A prospective study in DPHACTO.

    PubMed

    Hallman, David M; Birk Jørgensen, Marie; Holtermann, Andreas

    2017-05-01

    This study aimed to investigate the association between objectively measured physical activity at work and leisure and the intensity (mean level and time course) of neck-shoulder pain (NSP) over 12 months among male and female blue collar workers. Data were obtained from 625 blue collar workers from the Danish cohort DPHACTO. Physical activity was measured objectively at baseline using accelerometers. The percentage of time spent in physical activity (walking, climbing stairs, running and cycling) was calculated for both work and leisure time. Longitudinal data on the intensity of NSP (numerical rating scale 0-10) were collected using text messages every fourth week over 12 months. Linear mixed models were used to investigate the associations between occupational physical activity (OPA) and leisure time physical activity (LTPA) and the trajectories of the intensity of NSP, adjusted for individual, biomechanical and psychosocial factors, and baseline pain. OPA was not associated with the mean intensity of NSP over 12 months. LTPA was negatively associated with the mean intensity of NSP both among men ( B=-0.71, 95% CI -1.31 to -0.11) and women ( B=-0.85, 95% CI -1.57 to -0.13). Sex interactions on the 12-month trajectories of NSP showed that higher physical activity was associated with a slower reduction in NSP among men for OPA only ( B=0.03, 95% CI 0.01-0.05) and women for LTPA only ( B=0.05, 95% CI 0.00-0.09). We found that more time in LTPA was associated with a lower overall intensity of NSP over 12 months among blue collar workers. However, depending on sex and domain, high physical activity had an unfavourable effect on the course of NSP over 12 months.

  5. Multiscale Modeling in Computational Biomechanics: Determining Computational Priorities and Addressing Current Challenges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tawhai, Merryn; Bischoff, Jeff; Einstein, Daniel R.

    2009-05-01

    Abstract In this article, we describe some current multiscale modeling issues in computational biomechanics from the perspective of the musculoskeletal and respiratory systems and mechanotransduction. First, we outline the necessity of multiscale simulations in these biological systems. Then we summarize challenges inherent to multiscale biomechanics modeling, regardless of the subdiscipline, followed by computational challenges that are system-specific. We discuss some of the current tools that have been utilized to aid research in multiscale mechanics simulations, and the priorities to further the field of multiscale biomechanics computation.

  6. Editorial Commentary: All-Suture Anchors, Foam Blocks, and Biomechanical Testing.

    PubMed

    Brand, Jefferson C

    2017-06-01

    Barber's biomechanical work is well known to Arthroscopy's readers as thorough, comprehensive, and inclusive of new designs as they become available. In "All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode," the latest iteration, Barber and Herbert test all-suture anchors in both porcine femurs and biphasic foam. While we await in vivo clinical trials that compare all-suture anchors to currently used anchors, Barber and Herbert have provided data to inform anchor choice, and using their biomechanical data at time zero from all-suture anchor trials in an animal model, we can determine the anchors' feasibility for human clinical investigations. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Anterior Cruciate Ligament Biomechanics During Robotic and Mechanical Simulations of Physiologic and Clinical Motion Tasks: A Systematic Review and Meta-Analysis

    PubMed Central

    Bates, Nathaniel A.; Myer, Gregory D.; Shearn, Jason T.; Hewett, Timothy E.

    2014-01-01

    Investigators use in vitro joint simulations to invasively study the biomechanical behaviors of the anterior cruciate ligament. The aims of these simulations are to replicate physiologic conditions, but multiple mechanisms can be used to drive in vitro motions, which may influence biomechanical outcomes. The objective of this review was to examine, summarize, and compare biomechanical evidence related to anterior cruciate ligament function from in vitro simulations of knee motion. A systematic review was conducted (2004 to 2013) in Scopus, PubMed/Medline, and SPORTDiscus to identify peer-reviewed studies that reported kinematic and kinetic outcomes from in vitro simulations of physiologic or clinical tasks at the knee. Inclusion criteria for relevant studies were articles published in English that reported on whole-ligament anterior cruciate ligament mechanics during the in vitro simulation of physiologic or clinical motions on cadaveric knees that were unaltered outside of the anterior-cruciate-ligament-intact, -deficient, and -reconstructed conditions. A meta-analysis was performed to synthesize biomechanical differences between the anterior-cruciate-ligament-intact and reconstructed conditions. 77 studies met our inclusion/exclusion criteria and were reviewed. Combined joint rotations have the greatest impact on anterior cruciate ligament loads, but the magnitude by which individual kinematic degrees of freedom contribute to ligament loading during in vitro simulations is technique-dependent. Biomechanical data collected in prospective, longitudinal studies corresponds better with robotic-manipulator simulations than mechanical-impact simulations. Robotic simulation indicated that the ability to restore intact anterior cruciate ligament mechanics with anterior cruciate ligament reconstructions was dependent on loading condition and degree of freedom examined. PMID:25547070

  8. Biomechanics of Submaximal Recumbent Cycling in Adolescents With and Without Cerebral Palsy

    PubMed Central

    Johnston, Therese E; Barr, Ann E; Lee, Samuel CK

    2011-01-01

    Background and Purpose The purpose of this study was to compare the biomechanics of recumbent cycling between adolescents with cerebral palsy (CP) classified at Gross Motor Function Classification System (GMFCS) levels III and IV and adolescents with typical development (TD). Subjects Twenty subjects, ages (X̄±SD) 15.2±1.6 years (10 with TD, 10 with CP), participated. Methods Lower-extremity kinematics and muscle activity were measured at 30 and 60 rpm while subjects pedaled on a recumbent cycle. Energy expenditure and perceived exertion were measured during a 5-minute test, and efficiency was calculated. Noncircular data were analyzed with analyses of variance. Circular data were analyzed using circular t tests. Results Differences were found between groups for joint kinematics for all motions. Subjects with CP displayed earlier onsets and later offsets of muscle activity, increased co-contraction of agonist and antagonist muscles, and decreased efficiency compared with subjects with TD. There were no differences in perceived exertion. Discussion and Conclusion Differences in cycling biomechanics between children with CP and children with TD may be due to decreased strength and motor control in the children with CP. PMID:17405804

  9. Integrating physiological and biomechanical drivers of population growth over environmental gradients on coral reefs.

    PubMed

    Madin, Joshua S; Hoogenboom, Mia O; Connolly, Sean R

    2012-03-15

    Coral reefs exhibit marked spatial and temporal variability, and coral reef organisms exhibit trade-offs in functional traits that influence demographic performance under different combinations of abiotic environmental conditions. In many systems, trait trade-offs are modelled using an energy and/or nutrient allocation framework. However, on coral reefs, differences in biomechanical vulnerability have major demographic implications, and indeed are believed to play an essential role in mediating species coexistence because highly competitive growth forms are vulnerable to physical dislodgment events that occur with high frequency (e.g. annual summer storms). Therefore, an integrated energy allocation and biomechanics framework is required to understand the effect of physical environmental gradients on species' demographic performance. However, on coral reefs, as in most ecosystems, the effects of environmental conditions on organisms are measured in different currencies (e.g. lipid accumulation, survival and number of gametes), and thus the relative contributions of these effects to overall capacity for population growth are not readily apparent. A comprehensive assessment of links between the environment and the organism, including those mediated by biomechanical processes, must convert environmental effects on individual-level performance (e.g. survival, growth and reproduction) into a common currency that is relevant to the capacity to contribute to population growth. We outline such an approach by considering the population-level performance of scleractinian reef corals over a hydrodynamic gradient, with a focus on the integrating the biomechanical determinants of size-dependent coral colony dislodgment as a function of flow, with the effects of flow on photosynthetic energy acquisition and respiration.

  10. Sensitivity to biomechanical limitations during postural decision-making depends on the integrity of posterior superior parietal cortex.

    PubMed

    Wood, Daniel K; Chouinard, Philippe A; Major, Alex J; Goodale, Melvyn A

    2017-12-01

    Most object-directed limb movements can be carried out with a comfortable grasp posture. However, the orientation of an object relative to our bodies can sometimes lead us to select an uncomfortable or awkward grasp posture due to limitations imposed by the biomechanics of the arm. In a series of experiments, we identified a network of cortical areas that are engaged during the selection of movement strategies. Neurologically intact participants and two brain-damaged patients with overlapping lesions in the right posterior superior parietal lobule (pSPL) performed a grasp posture selection task in which biomechanical constraints were the primary consideration for selecting an action. The task induced states of bistable actions whereby the same stimulus gave rise to categorically different grasp postures. In a behavioral experiment, the two patients displayed a large range of manual bistability with the contralesional hand, resulting in a higher incidence of awkward grasping postures. In neurologically intact participants, a separate functional magnetic resonance imaging (fMRI) experiment revealed activation of a parieto-frontal network, which included the posterior intraparietal sulcus (pIPS) along the banks of the pSPL that was parametrically modulated by the degree of bistability in grasp posture selection. Superimposing this activation over the patients' structural MRIs revealed that the pIPS/pSPL activation in the neurologically intact participants overlapped with lesioned cortical tissue in both patients; all other areas of activation overlapped with intact cortical tissue in the patients. These results provide converging evidence that the posterior parietal cortex plays a critical role in selecting biomechanically appropriate postures during reach-to-grasp behaviors. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Biomechanics and mechanical signaling in the ovary: a systematic review.

    PubMed

    Shah, Jaimin S; Sabouni, Reem; Cayton Vaught, Kamaria C; Owen, Carter M; Albertini, David F; Segars, James H

    2018-04-24

    Mammalian oogenesis and folliculogenesis share a dynamic connection that is critical for gamete development. For maintenance of quiescence or follicular activation, follicles must respond to soluble signals (growth factors and hormones) and physical stresses, including mechanical forces and osmotic shifts. Likewise, mechanical processes are involved in cortical tension and cell polarity in oocytes. Our objective was to examine the contribution and influence of biomechanical signaling in female mammalian gametogenesis. We performed a systematic review to assess and summarize the effects of mechanical signaling and mechanotransduction in oocyte maturation and folliculogenesis and to explore possible clinical applications. The review identified 2568 publications of which 122 met the inclusion criteria. The integration of mechanical and cell signaling pathways in gametogenesis is complex. Follicular activation or quiescence are influenced by mechanical signaling through the Hippo and Akt pathways involving the yes-associated protein (YAP), transcriptional coactivator with PDZ-binding motif (TAZ), phosphatase and tensin homolog deleted from chromosome 10 (PTEN) gene, the mammalian target of rapamycin (mTOR), and forkhead box O3 (FOXO3) gene. There is overwhelming evidence that mechanical signaling plays a crucial role in development of the ovary, follicle, and oocyte throughout gametogenesis. Emerging data suggest the complexities of mechanotransduction and the biomechanics of oocytes and follicles are integral to understanding of primary ovarian insufficiency, ovarian aging, polycystic ovary syndrome, and applications of fertility preservation.

  12. Understanding how axial loads on the spine influence segmental biomechanics for idiopathic scoliosis patients: A magnetic resonance imaging study.

    PubMed

    Little, J P; Pearcy, M J; Izatt, M T; Boom, K; Labrom, R D; Askin, G N; Adam, C J

    2016-02-01

    Segmental biomechanics of the scoliotic spine are important since the overall spinal deformity is comprised of the cumulative coronal and axial rotations of individual joints. This study investigates the coronal plane segmental biomechanics for adolescent idiopathic scoliosis patients in response to physiologically relevant axial compression. Individual spinal joint compliance in the coronal plane was measured for a series of 15 idiopathic scoliosis patients using axially loaded magnetic resonance imaging. Each patient was first imaged in the supine position with no axial load, and then again following application of an axial compressive load. Coronal plane disc wedge angles in the unloaded and loaded configurations were measured. Joint moments exerted by the axial compressive load were used to derive estimates of individual joint compliance. The mean standing major Cobb angle for this patient series was 46°. Mean intra-observer measurement error for endplate inclination was 1.6°. Following loading, initially highly wedged discs demonstrated a smaller change in wedge angle, than less wedged discs for certain spinal levels (+2,+1,-2 relative to the apex, (p<0.05)). Highly wedged discs were observed near the apex of the curve, which corresponded to lower joint compliance in the apical region. While individual patients exhibit substantial variability in disc wedge angles and joint compliance, overall there is a pattern of increased disc wedging near the curve apex, and reduced joint compliance in this region. Approaches such as this can provide valuable biomechanical data on in vivo spinal biomechanics of the scoliotic spine, for analysis of deformity progression and surgical planning. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Three-Dimensional Shape Measurements of Specular Objects Using Phase-Measuring Deflectometry.

    PubMed

    Zhang, Zonghua; Wang, Yuemin; Huang, Shujun; Liu, Yue; Chang, Caixia; Gao, Feng; Jiang, Xiangqian

    2017-12-07

    The fast development in the fields of integrated circuits, photovoltaics, the automobile industry, advanced manufacturing, and astronomy have led to the importance and necessity of quickly and accurately obtaining three-dimensional (3D) shape data of specular surfaces for quality control and function evaluation. Owing to the advantages of a large dynamic range, non-contact operation, full-field and fast acquisition, high accuracy, and automatic data processing, phase-measuring deflectometry (PMD, also called fringe reflection profilometry) has been widely studied and applied in many fields. Phase information coded in the reflected fringe patterns relates to the local slope and height of the measured specular objects. The 3D shape is obtained by integrating the local gradient data or directly calculating the depth data from the phase information. We present a review of the relevant techniques regarding classical PMD. The improved PMD technique is then used to measure specular objects having discontinuous and/or isolated surfaces. Some influential factors on the measured results are presented. The challenges and future research directions are discussed to further advance PMD techniques. Finally, the application fields of PMD are briefly introduced.

  14. Three-Dimensional Shape Measurements of Specular Objects Using Phase-Measuring Deflectometry

    PubMed Central

    Wang, Yuemin; Huang, Shujun; Liu, Yue; Chang, Caixia; Gao, Feng; Jiang, Xiangqian

    2017-01-01

    The fast development in the fields of integrated circuits, photovoltaics, the automobile industry, advanced manufacturing, and astronomy have led to the importance and necessity of quickly and accurately obtaining three-dimensional (3D) shape data of specular surfaces for quality control and function evaluation. Owing to the advantages of a large dynamic range, non-contact operation, full-field and fast acquisition, high accuracy, and automatic data processing, phase-measuring deflectometry (PMD, also called fringe reflection profilometry) has been widely studied and applied in many fields. Phase information coded in the reflected fringe patterns relates to the local slope and height of the measured specular objects. The 3D shape is obtained by integrating the local gradient data or directly calculating the depth data from the phase information. We present a review of the relevant techniques regarding classical PMD. The improved PMD technique is then used to measure specular objects having discontinuous and/or isolated surfaces. Some influential factors on the measured results are presented. The challenges and future research directions are discussed to further advance PMD techniques. Finally, the application fields of PMD are briefly introduced. PMID:29215600

  15. Altered corneal biomechanical properties in children with osteogenesis imperfecta.

    PubMed

    Lagrou, Lisa M; Gilbert, Jesse; Hannibal, Mark; Caird, Michelle S; Thomas, Inas; Moroi, Sayoko E; Bohnsack, Brenda L

    2018-04-07

    To evaluate biomechanical corneal properties in children with osteogenesis imperfecta (OI). A prospective, observational, case-control study was conducted on children 6-19 years of age diagnosed with OI. Patients with OI and healthy control subjects underwent complete ophthalmic examinations. Additional tests included Ocular Response Analyzer (ORA) and ultrasonic pachymetry. Primary outcomes were central corneal thickness (CCT), corneal hysteresis (CH), and corneal resistance factor (CRF). Intraocular pressure (IOP) was measured directly by either iCare or Goldmann applanation and indirectly by the ORA (Goldmann-correlated and corneal-compensated IOP). Statistically significant differences between OI and control groups were determined using independent samples t test. A total of 10 of 18 OI cases (mean age, 13 ± 4.37 years; 8 males) and 30 controls (mean age, 12.76 ± 2.62 years; 16 males) were able to complete the corneal biomechanics and pachymetry testing. Children with OI had decreased CH (8.5 ± 1.0 mm Hg vs 11.6 ± 1.2 mm Hg [P < 0.001]), CRF (9.0 ± 1.9 mm Hg vs 11.5 ± 1.5 [P < 0.001]) and CCT (449.8 ± 30.8 μm vs 568 ± 47.6 μm [P < 0.001]) compared to controls. The corneal-compensated IOP was significantly higher in OI cases (18.8 ± 3.1 mm Hg) than in controls (15.0 ± 1.6 mm Hg, P < 0.004), but there was no significant difference in Goldmann-correlated IOP (16.3 ± 4.2 mm Hg vs 15.8 ± 2.2 mm Hg). Collagen defects in OI alter corneal structure and biomechanics. Children with OI have decreased CH, CRF, and CCT, resulting in IOPs that are likely higher than measured by tonometry. These corneal alterations are present at a young age in OI. Affected individuals should be routinely screened for glaucoma and corneal pathologies. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  16. Adiponectin, Leptin and Objectively Measured Physical Activity in Adults: A Narrative Review

    PubMed Central

    Nurnazahiah, Ali; Lua, Pei Lin; Shahril, Mohd Razif

    2016-01-01

    The objective of this study was to compile and analyse existing scientific evidences reporting the effects of objectively measured physical activity on the levels of adiponectin and leptin. Articles related to the effects of objectively measured physical activity on the levels of adiponectin and leptin were searched from the Medline and PubMed databases. The search was limited to ‘objectively measured’ physical activity, and studies that did not objectively measure the physical activity were excluded. Only English articles were included in the search and review. A total of 18 articles encompassing 2,026 respondents met the inclusion criteria. The eligible articles included all forms of evidence (e.g., cross-sectional and intervention). Seventeen and 11 studies showed the effects of objectively measured physical activity on adiponectin and leptin, respectively. Five and four cross-sectional studies showed the effects of objectively measured physical activity on adiponectin and leptin, respectively. Two out of five studies showed a weak to moderate positive association between adiponectin and objectively measured physical activity, while three out of four studies showed a weak to moderate inverse association between leptin and objectively measured physical activity. For intervention studies, six out of 12 studies involving adiponectin and five out of seven studies involving leptin showed a significant effect between the proteins and objectively measured physical activity. However, a definitive conclusion could not be drawn due to several methodological flaws in the existing articles and the acute lack of additional research in this area. In conclusion, the existing evidences are encouraging but yet not compelling. Hence, further well-designed large trials are needed before the effectiveness of objectively measured physical activity in elevating adiponectin levels and in decreasing leptin levels could be strongly confirmed. PMID:28090175

  17. Monitoring the athlete training response: subjective self-reported measures trump commonly used objective measures: a systematic review

    PubMed Central

    Saw, Anna E; Main, Luana C; Gastin, Paul B

    2016-01-01

    Background Monitoring athlete well-being is essential to guide training and to detect any progression towards negative health outcomes and associated poor performance. Objective (performance, physiological, biochemical) and subjective measures are all options for athlete monitoring. Objective We systematically reviewed objective and subjective measures of athlete well-being. Objective measures, including those taken at rest (eg, blood markers, heart rate) and during exercise (eg, oxygen consumption, heart rate response), were compared against subjective measures (eg, mood, perceived stress). All measures were also evaluated for their response to acute and chronic training load. Methods The databases Academic search complete, MEDLINE, PsycINFO, SPORTDiscus and PubMed were searched in May 2014. Fifty-six original studies reported concurrent subjective and objective measures of athlete well-being. The quality and strength of findings of each study were evaluated to determine overall levels of evidence. Results Subjective and objective measures of athlete well-being generally did not correlate. Subjective measures reflected acute and chronic training loads with superior sensitivity and consistency than objective measures. Subjective well-being was typically impaired with an acute increase in training load, and also with chronic training, while an acute decrease in training load improved subjective well-being. Summary This review provides further support for practitioners to use subjective measures to monitor changes in athlete well-being in response to training. Subjective measures may stand alone, or be incorporated into a mixed methods approach to athlete monitoring, as is current practice in many sport settings. PMID:26423706

  18. Biomechanics of injury prediction for anthropomorphic manikins - preliminary design considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engin, A.E.

    1996-12-31

    The anthropomorphic manikins are used in automobile safety research as well as in aerospace related applications. There is now a strong need to advance the biomechanics knowledge to determine appropriate criteria for injury likelihood prediction as functions of manikin-measured responses. In this paper, three regions of a manikin, namely, the head, knee joint, and lumbar spine are taken as examples to introduce preliminary design considerations for injury prediction by means of responses of theoretical models and strategically placed sensing devices.

  19. First delivery and ovariectomy affect biomechanical and structural properties of the vagina in the ovine model.

    PubMed

    Urbankova, Iva; Callewaert, Geertje; Blacher, Silvia; Deprest, Dries; Hympanova, Lucie; Feola, Andrew; De Landsheere, Laurent; Deprest, Jan

    2018-01-08

    Animal models are useful for investigating the genesis of pelvic floor dysfunction and for developing novel therapies for its treatment. There is a need for an alternative large-animal model to the nonhuman primate. Therefore we studied the effects of the first vaginal delivery, ovariectomy and systemic hormonal replacement therapy (HRT) on the biomechanical and structural properties of the ovine vagina. We examined the gross anatomical properties of nulliparous, primiparous, ovariectomized multiparous, and ovariectomized hormone-replaced multiparous sheep (six animals per group). We also harvested mid-vaginal and distal vaginal tissue to determine smooth muscle contractility and passive biomechanical properties, for morphometric assessment of the vaginal wall layers, to determine collagen and elastin content, and for immunostaining for α-smooth muscle actin and estrogen receptor-α. There were no regional differences in the nulliparous vagina. One year after the first vaginal delivery, stiffness and contractility of the distal vagina were decreased, whereas the elastin content increased. The mid-vagina of ovariectomized sheep was stiff, and its epithelium was thin and lacked glycogen. HRT decreased the stiffness of the mid-vagina by 45% but had no measurable effect on contractility or elastin content, and increased epithelial thickness and glycogen content. HRT also increased the epithelial thickness and glycogen content of the distal vagina. At this location, there were no changes in morphology or stiffness. In sheep, life events including delivery and ovariectomy affect the biomechanical properties of the vagina in a region-specific way. Vaginal delivery mainly affects the distal region by decreasing stiffness and contractility. HRT can reverse the increase in stiffness of the mid-vagina observed after surgical induction of menopause. These observations are in line with scanty biomechanical measurements in comparable clinical specimens.

  20. Executive function in fibromyalgia: Comparing subjective and objective measures.

    PubMed

    Gelonch, Olga; Garolera, Maite; Valls, Joan; Rosselló, Lluís; Pifarré, Josep

    2016-04-01

    There is evidence to suggest the existence of an executive dysfunction in people diagnosed with fibromyalgia, although there are certain inconsistencies between studies. Here, we aim to compare executive performance between patients with fibromyalgia and a control group by using subjective and objective cognitive tests, analyzing the influence of patient mood on the results obtained, and studying associations between the two measures. 82 patients diagnosed with fibromyalgia and 42 healthy controls, matched by age and years of education, were assessed using the Behavioral Rating Inventory of Executive Function - Adult Version (BRIEF-A) as a subjective measure of executive functioning. A selection of objective cognitive tests were also used to measure a series of executive functions and to identify symptoms of depression and anxiety. Patients with fibromyalgia perceived greater difficulties than the control group on all of the BRIEF-A scales. However, after adjustments were made for depression and anxiety the only differences that remained were those associated with the working memory scale and the Metacognition and Global Executive Composite index. In the case of the objective cognitive tests, a significantly worse overall performance was evidenced for the fibromyalgia patients. However, this also disappeared when adjustments were made for depression and anxiety. After this adjustment, fibromyalgia patients only performed significantly worse for the interference effect in the Stroop Test. Although there were no significant associations between most of the objective cognitive tests and the BRIEF-A scales, depression and anxiety exhibited strong associations with almost all of the BRIEF-A scales and with several of the objective cognitive tests. Patients with fibromyalgia showed executive dysfunction in subjective and objective measures, although most of this impairment was associated with mood disturbances. Exceptions to this general rule were observed in the

  1. Biomechanics of the Chick Embryonic Heart Outflow Tract at HH18 Using 4D Optical Coherence Tomography Imaging and Computational Modeling

    PubMed Central

    Liu, Aiping; Yin, Xin; Shi, Liang; Li, Peng; Thornburg, Kent L.; Wang, Ruikang; Rugonyi, Sandra

    2012-01-01

    During developmental stages, biomechanical stimuli on cardiac cells modulate genetic programs, and deviations from normal stimuli can lead to cardiac defects. Therefore, it is important to characterize normal cardiac biomechanical stimuli during early developmental stages. Using the chicken embryo model of cardiac development, we focused on characterizing biomechanical stimuli on the Hamburger–Hamilton (HH) 18 chick cardiac outflow tract (OFT), the distal portion of the heart from which a large portion of defects observed in humans originate. To characterize biomechanical stimuli in the OFT, we used a combination of in vivo optical coherence tomography (OCT) imaging, physiological measurements and computational fluid dynamics (CFD) modeling. We found that, at HH18, the proximal portion of the OFT wall undergoes larger circumferential strains than its distal portion, while the distal portion of the OFT wall undergoes larger wall stresses. Maximal wall shear stresses were generally found on the surface of endocardial cushions, which are protrusions of extracellular matrix onto the OFT lumen that later during development give rise to cardiac septa and valves. The non-uniform spatial and temporal distributions of stresses and strains in the OFT walls provide biomechanical cues to cardiac cells that likely aid in the extensive differential growth and remodeling patterns observed during normal development. PMID:22844414

  2. Biomechanical analyses of prolonged handwriting in subjects with and without perceived discomfort.

    PubMed

    Chang, Shao-Hsia; Chen, Chien-Liang; Yu, Nan-Ying

    2015-10-01

    Since wrist-joint position affects finger muscle length and grip strength, we studied its biomechanical relevance in prolonged handwriting. We recruited participants from young adults, aged 18-24, and separated them into control (n=22) and in-pain (n=18) groups, based whether or not they experience pain while handwriting. The participants then performed a writing task for 30 min on a computerized system which measured their wrist-joint angle and documented their handwriting kinematics. The in-pain group perceived more soreness and had a less-extended wrist joint, longer on-paper time, and slower stroke velocity compared to control group. There was no significant difference in handwriting speed and quality between the two groups. The wrist extension angle significantly correlated with perceived soreness. Ergonomic and biomechanical analyses provide important information about the handwriting process. Knowledge of pen tip movement kinematics and wrist-joint position can help occupational therapists plan treatment for individuals with handwriting induced pain. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Prediction of biomechanical parameters of the proximal femur using statistical appearance models and support vector regression.

    PubMed

    Fritscher, Karl; Schuler, Benedikt; Link, Thomas; Eckstein, Felix; Suhm, Norbert; Hänni, Markus; Hengg, Clemens; Schubert, Rainer

    2008-01-01

    Fractures of the proximal femur are one of the principal causes of mortality among elderly persons. Traditional methods for the determination of femoral fracture risk use methods for measuring bone mineral density. However, BMD alone is not sufficient to predict bone failure load for an individual patient and additional parameters have to be determined for this purpose. In this work an approach that uses statistical models of appearance to identify relevant regions and parameters for the prediction of biomechanical properties of the proximal femur will be presented. By using Support Vector Regression the proposed model based approach is capable of predicting two different biomechanical parameters accurately and fully automatically in two different testing scenarios.

  4. Evaluation of lumbar segmental instability in degenerative diseases by using a new intraoperative measurement system.

    PubMed

    Hasegawa, Kazuhiro; Kitahara, Ko; Hara, Toshiaki; Takano, Ko; Shimoda, Haruka; Homma, Takao

    2008-03-01

    In vivo quantitative measurement of lumbar segmental stability has not been established. The authors developed a new measurement system to determine intraoperative lumbar stability. The objective of this study was to clarify the biomechanical properties of degenerative lumbar segments by using the new method. Twenty-two patients with a degenerative symptomatic segment were studied and their measurements compared with those obtained in normal or asymptomatic degenerative segments (Normal group). The measurement system produces cyclic flexion-extension through spinous process holders by using a computer-controlled motion generator with all ligamentous structures intact. The following biomechanical parameters were determined: stiffness, absorption energy (AE), and neutral zone (NZ). Discs with degeneration were divided into 2 groups based on magnetic resonance imaging grading: degeneration without collapse (Collapse[-]) and degeneration with collapse (Collapse[+]). Biomechanical parameters were compared among the groups. Relationships among the biomechanical parameters and age, diagnosis, or radiographic parameters were analyzed. The mean stiffness value in the Normal group was significantly greater than that in Collapse(-) or Collapse(+) group. There was no significant difference in the average AE value among the Normal, Collapse(-), and Collapse(+) groups. The NZ in the Collapse(-) was significantly higher than in the Normal or Collapse(+) groups. Stiffness was negatively and NZ was positively correlated with age. Stiffness demonstrated a significant negative and NZ a significant positive relationship with disc height, however. There were no significant differences in stiffness between spines in the Collapse(-) and Collapse(+) groups. The values of a more sensitive parameter, NZ, were higher in Collapse(-) than in Collapse(+) groups, demonstrating that degenerative segments with preserved disc height have a latent instability compared to segments with collapsed

  5. Quantitative method for measuring heat flux emitted from a cryogenic object

    DOEpatents

    Duncan, Robert V.

    1993-01-01

    The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infra-red sensing devices.

  6. Quantitative method for measuring heat flux emitted from a cryogenic object

    DOEpatents

    Duncan, R.V.

    1993-03-16

    The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infrared sensing devices.

  7. Foot Type Biomechanics Part 1: Structure and Function of the Asymptomatic Foot

    PubMed Central

    Hillstrom, Howard J.; Song, Jinsup; Kraszewski, Andrew P.; Hafer, Jocelyn F.; Mootanah, Rajshree; Dufour, Alyssa B.; PT, Betty (Shingpui) Chow; Deland, Jonathan T.

    2012-01-01

    Background Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? Aim To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Methods Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMatII gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pairwise comparisons. Results Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Conclusions Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. PMID:23107625

  8. Foot type biomechanics part 1: structure and function of the asymptomatic foot.

    PubMed

    Hillstrom, Howard J; Song, Jinsup; Kraszewski, Andrew P; Hafer, Jocelyn F; Mootanah, Rajshree; Dufour, Alyssa B; Chow, Betty Shingpui; Deland, Jonathan T

    2013-03-01

    Differences in foot structure are thought to be associated with differences in foot function during movement. Many foot pathologies are of a biomechanical nature and often associated with foot type. Fundamental to the understanding of foot pathomechanics is the question: do different foot types have distinctly different structure and function? To determine if objective measures of foot structure and function differ between planus, rectus and cavus foot types in asymptomatic individuals. Sixty-one asymptomatic healthy adults between 18 and 77 years old, that had the same foot type bilaterally (44 planus feet, 54 rectus feet, and 24 cavus feet), were recruited. Structural and functional measurements were taken using custom equipment, an emed-x plantar pressure measuring device, a GaitMat II gait pattern measurement system, and a goniometer. Generalized Estimation Equation modeling was employed to determine if each dependent variable of foot structure and function was significantly different across foot type while accounting for potential dependencies between sides. Post hoc testing was performed to assess pair wise comparisons. Several measures of foot structure (malleolar valgus index and arch height index) were significantly different between foot types. Gait pattern parameters were invariant across foot types. Peak pressure, maximum force, pressure-time-integral, force-time-integral and contact area were significantly different in several medial forefoot and arch locations between foot types. Planus feet exhibited significantly different center of pressure excursion indices compared to rectus and cavus feet. Planus, rectus and cavus feet exhibited significantly different measures of foot structure and function. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Numerical reconstruction and injury biomechanism in a car-pedestrian crash accident.

    PubMed

    Zou, Dong-Hua; Li, Zheng-Dong; Shao, Yu; Feng, Hao; Chen, Jian-Guo; Liu, Ning-Guo; Huang, Ping; Chen, Yi-Jiu

    2012-12-01

    To reconstruct a car-pedestrian crash accident using numerical simulation technology and explore the injury biomechanism as forensic evidence for injury identification. An integration of multi-body dynamic, finite element (FE), and classical method was applied to a car-pedestrian crash accident. The location of the collision and the details of the traffic accident were determined by vehicle trace verification and autopsy. The accident reconstruction was performed by coupling the three-dimensional car behavior from PC-CRASH with a MADYMO dummy model. The collision FE models of head and leg, developed from CT scans of human remains, were loaded with calculated dummy collision parameters. The data of the impact biomechanical responses were extracted in terms of von Mises stress, relative displacement, strain and stress fringes. The accident reconstruction results were identical with the examined ones and the biomechanism of head and leg injuries, illustrated through the FE methods, were consistent with the classical injury theories. The numerical simulation technology is proved to be effective in identifying traffic accidents and exploring of injury biomechanism.

  10. Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer.

    PubMed

    Frings, Andreas; Linke, Stephan J; Bauer, Eva L; Druchkiv, Vasyl; Katz, Toam; Steinberg, Johannes

    2015-01-01

    This study was initiated to evaluate biomechanical changes using the Corvis ST tonometer (CST) on the cornea after laser in situ keratomileusis (LASIK). University Medical Center Hamburg-Eppendorf, Germany, and Care Vision Refractive Centers, Germany. Retrospective cohort study. This retrospective study included 37 eyes of 37 refractive patients. All CST measurements were performed 1 day before surgery and at the 1-month follow-up examination. The LASIK procedure included mechanical flap preparation using a Moria SBK microkeratome and an Allegretto excimer laser platform. Statistically significant differences were observed for mean first applanation length, mean first and second deflection lengths, mean first and second deflection amplitudes, radius of curvature, and peak distance. Significant positive correlations were found between the change (Δ) of radius of curvature and manifest refraction spherical equivalent (MRSE), ablation depth, and Δintraocular pressure as well as between AD and ΔHC-time. Each diopter of myopic correction in MRSE resulted in an increase in Δradius of curvature of 0.2 mm. Several CST parameters were statistically significantly altered by LASIK, thereby indicating that flap creation, ablation, or both, significantly change the ability of the cornea to absorb or dissipate energy.

  11. Biomechanical effects of hydration in vocal fold tissues.

    PubMed

    Chan, Roger W; Tayama, Niro

    2002-05-01

    It has often been hypothesized, with little empirical support, that vocal fold hydration affects voice production by mediating changes in vocal fold tissue rheology. To test this hypothesis, we attempted in this study to quantify the effects of hydration on the viscoelastic shear properties of vocal fold tissues in vitro. Osmotic changes in hydration (dehydration and rehydration) of 5 excised canine larynges were induced by sequential incubation of the tissues in isotonic, hypertonic, and hypotonic solutions. Elastic shear modulus (G'), dynamic viscosity eta' and the damping ratio zeta of the vocal fold mucosa (lamina propria) were measured as a function of frequency (0.01 to 15 Hz) with a torsional rheometer. Vocal fold tissue stiffness (G') and viscosity (eta) increased significantly (by 4 to 7 times) with the osmotically induced dehydration, whereas they decreased by 22% to 38% on the induced rehydration. Damping ratio (zeta) also increased with dehydration and decreased with rehydration, but the detected differences were not statistically significant at all frequencies. These findings support the long-standing hypothesis that hydration affects vocal fold vibration by altering tissue rheologic (or viscoelastic) properties. Our results demonstrated the biomechanical importance of hydration in vocal fold tissues and suggested that hydration approaches may potentially improve the biomechanics of phonation in vocal fold lesions involving disordered fluid balance.

  12. Dietary water affects human skin hydration and biomechanics.

    PubMed

    Palma, Lídia; Marques, Liliana Tavares; Bujan, Julia; Rodrigues, Luís Monteiro

    2015-01-01

    It is generally assumed that dietary water might be beneficial for the health, especially in dermatological (age preventing) terms. The present study was designed to quantify the impact of dietary water on major indicators of skin physiology. A total of 49 healthy females (mean 24.5±4.3 years) were selected and characterized in terms of their dietary daily habits, especially focused in water consumption, by a Food Frequency Questionnaire. This allowed two groups to be set - Group 1 consuming less than 3,200 mL/day (n=38), and Group 2 consuming more than 3,200 mL/day (n=11). Approximately 2 L of water were added to the daily diet of Group 2 individuals for 1 month to quantify the impact of this surplus in their skin physiology. Measurements involving epidermal superficial and deep hydration, transepidermal water loss, and several biomechanical descriptors were taken at day 0 (T0), 15 (T1), and 30 (T2) in several anatomical sites (face, upper limb, and leg). This stress test (2 L/day for 30 days) significantly modified superficial and deep skin hydration, especially in Group 1. The same impact was registered with the most relevant biomechanical descriptors. Thus, in this study, it is clear that higher water inputs in regular diet might positively impact normal skin physiology, in particular in those individuals with lower daily water consumptions.

  13. The effect of gender and fatigue on the biomechanics of bilateral landings from a jump: peak values.

    PubMed

    Pappas, Evangelos; Sheikhzadeh, Ali; Hagins, Marshall; Nordin, Margareta

    2007-01-01

    Female athletes are substantially more susceptible than males to suffer acute non-contact anterior cruciate ligament injury. A limited number of studies have identified possible biomechanical risk factors that differ between genders. The effect of fatigue on the biomechanics of landing has also been inadequately investigated. The objective of the study was to examine the effect of gender and fatigue on peak values of biomechanical variables during landing from a jump. Thirty-two recreational athletes performed bilateral drop jump landings from a 40 cm platform. Kinetic, kinematic and electromyographic data were collected before and after a functional fatigue protocol. Females landed with 9° greater peak knee valgus (p = 0.001) and 140% greater maximum vertical ground reaction forces (p = 0.003) normalized to body weight compared to males. Fatigue increased peak foot abduction by 1.7° (p = 0.042), peak rectus femoris activity by 27% (p = 0.018), and peak vertical ground reaction force (p = 0.038) by 20%. The results of the study suggest that landing with increased peak knee valgus and vertical ground reaction force may contribute to increased risk for knee injury in females. Fatigue caused significant but small changes on some biomechanical variables. Anterior cruciate ligament injury prevention programs should focus on implementing strategies to effectively teach females to control knee valgus and ground reaction force. Key pointsFemale athletes landed with increased knee valgus and VGRF which may predispose them to ACL injury.Fatigue elicited a similar response in male and female athletes.The effectiveness of sports injury prevention programs may improve by focusing on teaching females to land softer and with less knee valgus.

  14. The Effect of Gender and Fatigue on the Biomechanics of Bilateral Landings from a Jump: Peak Values

    PubMed Central

    Pappas, Evangelos; Sheikhzadeh, Ali; Hagins, Marshall; Nordin, Margareta

    2007-01-01

    Female athletes are substantially more susceptible than males to suffer acute non-contact anterior cruciate ligament injury. A limited number of studies have identified possible biomechanical risk factors that differ between genders. The effect of fatigue on the biomechanics of landing has also been inadequately investigated. The objective of the study was to examine the effect of gender and fatigue on peak values of biomechanical variables during landing from a jump. Thirty-two recreational athletes performed bilateral drop jump landings from a 40 cm platform. Kinetic, kinematic and electromyographic data were collected before and after a functional fatigue protocol. Females landed with 9° greater peak knee valgus (p = 0.001) and 140% greater maximum vertical ground reaction forces (p = 0.003) normalized to body weight compared to males. Fatigue increased peak foot abduction by 1.7° (p = 0.042), peak rectus femoris activity by 27% (p = 0.018), and peak vertical ground reaction force (p = 0.038) by 20%. The results of the study suggest that landing with increased peak knee valgus and vertical ground reaction force may contribute to increased risk for knee injury in females. Fatigue caused significant but small changes on some biomechanical variables. Anterior cruciate ligament injury prevention programs should focus on implementing strategies to effectively teach females to control knee valgus and ground reaction force. Key pointsFemale athletes landed with increased knee valgus and VGRF which may predispose them to ACL injury.Fatigue elicited a similar response in male and female athletes.The effectiveness of sports injury prevention programs may improve by focusing on teaching females to land softer and with less knee valgus. PMID:24149228

  15. Preventive Biomechanics: A Paradigm Shift With a Translational Approach to Injury Prevention.

    PubMed

    Hewett, Timothy E; Bates, Nathaniel A

    2017-09-01

    Preventive medicine techniques have alleviated billions of dollars' worth of the economic burden in the medical care system through the implementation of vaccinations and screenings before the onset of disease symptoms. Knowledge of biomechanical tendencies has progressed rapidly over the past 20 years such that clinicians can identify, in healthy athletes, the underlying mechanisms that lead to catastrophic injuries such as anterior cruciate ligament (ACL) ruptures. As such, preventive medicine concepts can be applied to noncontact musculoskeletal injuries to reduce the economic burden of sports medicine treatments and enhance the long-term health of athletes. To illustrate the practical medical benefits that could be gained from preventive biomechanics applied to the ACL as well as the need and feasibility for the broad implementation of these principles. Literature review. The recent literature pertinent to the screening and prevention of musculoskeletal injuries was reviewed and compiled into a clinical commentary on the current state and applicability of preventive biomechanics. Investigators have identified neuromuscular training protocols that screen for and correct the underlying biomechanical deficits that lead to ACL injuries. The literature shows that when athletes comply with these prescribed training protocols, the incidence of injuries is significantly reduced within that population. Such preventive biomechanics practices employ basic training methods that would be familiar to athletic coaches and have the potential to save billions of dollars in cost in sports medicine. The widespread implementation of preventive biomechanics concepts could profoundly affect the field of sports medicine with a minimum of initial investment.

  16. Associations between iliotibial band injury status and running biomechanics in women.

    PubMed

    Foch, Eric; Reinbolt, Jeffrey A; Zhang, Songning; Fitzhugh, Eugene C; Milner, Clare E

    2015-02-01

    Iliotibial band syndrome (ITBS) is a common overuse knee injury that is twice as likely to afflict women compared to men. Lower extremity and trunk biomechanics during running, as well as hip abductor strength and iliotibial band flexibility, are factors believed to be associated with ITBS. The purpose of this cross-sectional study was to determine if differences in lower extremity and trunk biomechanics during running exist among runners with current ITBS, previous ITBS, and controls. Additionally, we sought to determine if isometric hip abductor strength and iliotibial band flexibility were different among groups. Twenty-seven female runners participated in the study. Participants were divided into three equal groups: current ITBS, previous ITBS, and controls. Overground running trials, isometric hip abductor strength, and iliotibial band flexibility were recorded for all participants. Discrete joint and segment biomechanics, as well as hip strength and flexibility measures were analyzed using a one-way analysis of variance. Runners with current ITBS exhibited 1.8 (1.5)° greater trunk ipsilateral flexion and 7 (6)° less iliotibial band flexibility compared to runners with previous ITBS and controls. Runners with previous ITBS exhibited 2.2 (2.9) ° less hip adduction compared to runners with current ITBS and controls. Hip abductor strength 3.3 (2.6) %BM×h was less in runners with previous ITBS but not current ITBS compared to controls. Runners with current ITBS may lean their trunk more towards the stance limb which may be associated with decreased iliotibial band flexibility. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Ultrasound Elasticity Imaging System with Chirp-Coded Excitation for Assessing Biomechanical Properties of Elasticity Phantom

    PubMed Central

    Chun, Guan-Chun; Chiang, Hsing-Jung; Lin, Kuan-Hung; Li, Chien-Ming; Chen, Pei-Jarn; Chen, Tainsong

    2015-01-01

    The biomechanical properties of soft tissues vary with pathological phenomenon. Ultrasound elasticity imaging is a noninvasive method used to analyze the local biomechanical properties of soft tissues in clinical diagnosis. However, the echo signal-to-noise ratio (eSNR) is diminished because of the attenuation of ultrasonic energy by soft tissues. Therefore, to improve the quality of elastography, the eSNR and depth of ultrasound penetration must be increased using chirp-coded excitation. Moreover, the low axial resolution of ultrasound images generated by a chirp-coded pulse must be increased using an appropriate compression filter. The main aim of this study is to develop an ultrasound elasticity imaging system with chirp-coded excitation using a Tukey window for assessing the biomechanical properties of soft tissues. In this study, we propose an ultrasound elasticity imaging system equipped with a 7.5-MHz single-element transducer and polymethylpentene compression plate to measure strains in soft tissues. Soft tissue strains were analyzed using cross correlation (CC) and absolution difference (AD) algorithms. The optimal parameters of CC and AD algorithms used for the ultrasound elasticity imaging system with chirp-coded excitation were determined by measuring the elastographic signal-to-noise ratio (SNRe) of a homogeneous phantom. Moreover, chirp-coded excitation and short pulse excitation were used to measure the elasticity properties of the phantom. The elastographic qualities of the tissue-mimicking phantom were assessed in terms of Young’s modulus and elastographic contrast-to-noise ratio (CNRe). The results show that the developed ultrasound elasticity imaging system with chirp-coded excitation modulated by a Tukey window can acquire accurate, high-quality elastography images. PMID:28793718

  18. Relative hardness measurement of soft objects by a new fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Ahmadi, Roozbeh; Ashtaputre, Pranav; Abou Ziki, Jana; Dargahi, Javad; Packirisamy, Muthukumaran

    2010-06-01

    The measurement of relative hardness of soft objects enables replication of human finger tactile perception capabilities. This ability has many applications not only in automation and robotics industry but also in many other areas such as aerospace and robotic surgery where a robotic tool interacts with a soft contact object. One of the practical examples of interaction between a solid robotic instrument and a soft contact object occurs during robotically-assisted minimally invasive surgery. Measuring the relative hardness of bio-tissue, while contacting the robotic instrument, helps the surgeons to perform this type of surgery more reliably. In the present work, a new optical sensor is proposed to measure the relative hardness of contact objects. In order to measure the hardness of a contact object, like a human finger, it is required to apply a small force/deformation to the object by a tactile sensor. Then, the applied force and resulting deformation should be recorded at certain points to enable the relative hardness measurement. In this work, force/deformation data for a contact object is recorded at certain points by the proposed optical sensor. Recorded data is used to measure the relative hardness of soft objects. Based on the proposed design, an experimental setup was developed and experimental tests were performed to measure the relative hardness of elastomeric materials. Experimental results verify the ability of the proposed optical sensor to measure the relative hardness of elastomeric samples.

  19. Biomechanics of the elbow joint in tennis players and relation to pathology

    PubMed Central

    Eygendaal, Denise; Rahussen, F T G; Diercks, R L

    2007-01-01

    Elbow injuries constitute a sizeable percentage of tennis injuries. A basic understanding of biomechanics of tennis and analysis of the forces, loads and motions of the elbow during tennis will improve the understanding of the pathophysiology of these injuries. All different strokes in tennis have a different repetitive biomechanical nature that can result in tennis‐related injuries. In this article, a biomechanically‐based evaluation of tennis strokes is presented. This overview includes all tennis‐related pathologies of the elbow joint, whereby the possible relation of biomechanics to pathology is analysed, followed by treatment recommendations. PMID:17638843

  20. WHAT IS A MOMENT ARM? CALCULATING MUSCLE EFFECTIVENESS IN BIOMECHANICAL MODELS USING GENERALIZED COORDINATES

    PubMed Central

    Seth, Ajay; Delp, Scott L.

    2015-01-01

    Biomechanics researchers often use multibody models to represent biological systems. However, the mapping from biology to mechanics and back can be problematic. OpenSim is a popular open source tool used for this purpose, mapping between biological specifications and an underlying generalized coordinate multibody system called Simbody. One quantity of interest to biomechanical researchers and clinicians is “muscle moment arm,” a measure of the effectiveness of a muscle at contributing to a particular motion over a range of configurations. OpenSim can automatically calculate these quantities for any muscle once a model has been built. For simple cases, this calculation is the same as the conventional moment arm calculation in mechanical engineering. But a muscle may span several joints (e.g., wrist, neck, back) and may follow a convoluted path over various curved surfaces. A biological joint may require several bodies or even a mechanism to accurately represent in the multibody model (e.g., knee, shoulder). In these situations we need a careful definition of muscle moment arm that is analogous to the mechanical engineering concept, yet generalized to be of use to biomedical researchers. Here we present some biomechanical modeling challenges and how they are resolved in OpenSim and Simbody to yield biologically meaningful muscle moment arms. PMID:25905111

  1. WHAT IS A MOMENT ARM? CALCULATING MUSCLE EFFECTIVENESS IN BIOMECHANICAL MODELS USING GENERALIZED COORDINATES.

    PubMed

    Sherman, Michael A; Seth, Ajay; Delp, Scott L

    2013-08-01

    Biomechanics researchers often use multibody models to represent biological systems. However, the mapping from biology to mechanics and back can be problematic. OpenSim is a popular open source tool used for this purpose, mapping between biological specifications and an underlying generalized coordinate multibody system called Simbody. One quantity of interest to biomechanical researchers and clinicians is "muscle moment arm," a measure of the effectiveness of a muscle at contributing to a particular motion over a range of configurations. OpenSim can automatically calculate these quantities for any muscle once a model has been built. For simple cases, this calculation is the same as the conventional moment arm calculation in mechanical engineering. But a muscle may span several joints (e.g., wrist, neck, back) and may follow a convoluted path over various curved surfaces. A biological joint may require several bodies or even a mechanism to accurately represent in the multibody model (e.g., knee, shoulder). In these situations we need a careful definition of muscle moment arm that is analogous to the mechanical engineering concept, yet generalized to be of use to biomedical researchers. Here we present some biomechanical modeling challenges and how they are resolved in OpenSim and Simbody to yield biologically meaningful muscle moment arms.

  2. Development of a biomechanical energy harvester.

    PubMed

    Li, Qingguo; Naing, Veronica; Donelan, J Maxwell

    2009-06-23

    Biomechanical energy harvesting-generating electricity from people during daily activities-is a promising alternative to batteries for powering increasingly sophisticated portable devices. We recently developed a wearable knee-mounted energy harvesting device that generated electricity during human walking. In this methods-focused paper, we explain the physiological principles that guided our design process and present a detailed description of our device design with an emphasis on new analyses. Effectively harvesting energy from walking requires a small lightweight device that efficiently converts intermittent, bi-directional, low speed and high torque mechanical power to electricity, and selectively engages power generation to assist muscles in performing negative mechanical work. To achieve this, our device used a one-way clutch to transmit only knee extension motions, a spur gear transmission to amplify the angular speed, a brushless DC rotary magnetic generator to convert the mechanical power into electrical power, a control system to determine when to open and close the power generation circuit based on measurements of knee angle, and a customized orthopaedic knee brace to distribute the device reaction torque over a large leg surface area. The device selectively engaged power generation towards the end of swing extension, assisting knee flexor muscles by producing substantial flexion torque (6.4 Nm), and efficiently converted the input mechanical power into electricity (54.6%). Consequently, six subjects walking at 1.5 m/s generated 4.8 +/- 0.8 W of electrical power with only a 5.0 +/- 21 W increase in metabolic cost. Biomechanical energy harvesting is capable of generating substantial amounts of electrical power from walking with little additional user effort making future versions of this technology particularly promising for charging portable medical devices.

  3. Teaching practices of the undergraduate introductory biomechanics faculty: a North American survey.

    PubMed

    Garceau, Luke R; Ebben, William P; Knudson, Duane V

    2012-11-01

    Instruction and assessment strategies of undergraduate introductory biomechanics instructors have yet to be comprehensively examined. The purpose of this study was to identify the current instruction and assessment practices of North American undergraduate introductory biomechanics instructors and equipment needed for effective instruction in lecture and laboratory sessions. One hundred and sixty-five respondents (age: 42.5 +/- 10.3 years) who currently teach or have taught an introductory biomechanics course in North America were recruited by electronic mail. Subjects completed a web-based survey, consisting of 60 open- and closed-ended questions. Pearson's correlation coefficients were used to assess relationships between instructor's familiarity with either the Biomechanics Concept Inventory or the NASPE Guidelines for Undergraduate Biomechanics, and instructor and course characteristics (number of years teaching, age, faculty rank, number of quizzes given, etc.) A number of variables were significantly (p < 0.05) correlated. Answers to open-ended questions were processed using content analysis, with results categorized in content areas including: instructor and course characteristics; lecture instruction; assessment and equipment; laboratory instruction; assessment and equipment; and instructor's perspectives. Many active learning strategies for lecture and laboratory instruction were identified by faculty. Limited student preparation and limited resources were noted as the instructor's most common challenges.

  4. Multiscale modeling methods in biomechanics.

    PubMed

    Bhattacharya, Pinaki; Viceconti, Marco

    2017-05-01

    More and more frequently, computational biomechanics deals with problems where the portion of physical reality to be modeled spans over such a large range of spatial and temporal dimensions, that it is impossible to represent it as a single space-time continuum. We are forced to consider multiple space-time continua, each representing the phenomenon of interest at a characteristic space-time scale. Multiscale models describe a complex process across multiple scales, and account for how quantities transform as we move from one scale to another. This review offers a set of definitions for this emerging field, and provides a brief summary of the most recent developments on multiscale modeling in biomechanics. Of all possible perspectives, we chose that of the modeling intent, which vastly affect the nature and the structure of each research activity. To the purpose we organized all papers reviewed in three categories: 'causal confirmation,' where multiscale models are used as materializations of the causation theories; 'predictive accuracy,' where multiscale modeling is aimed to improve the predictive accuracy; and 'determination of effect,' where multiscale modeling is used to model how a change at one scale manifests in an effect at another radically different space-time scale. Consistent with how the volume of computational biomechanics research is distributed across application targets, we extensively reviewed papers targeting the musculoskeletal and the cardiovascular systems, and covered only a few exemplary papers targeting other organ systems. The review shows a research subdomain still in its infancy, where causal confirmation papers remain the most common. WIREs Syst Biol Med 2017, 9:e1375. doi: 10.1002/wsbm.1375 For further resources related to this article, please visit the WIREs website. © 2017 The Authors. WIREs Systems Biology and Medicine published by Wiley Periodicals, Inc.

  5. Biomechanics of volunteers subject to loading by a motorized shoulder belt tensioner.

    PubMed

    Good, Craig A; Viano, David C; Ronsky, Janet L

    2008-04-15

    A biomechanical study using human volunteers. Motorized shoulder belt tensioning is a new seatbelt technology that is likely to be incorporated into future vehicles. The objective of this study was to characterize the upper torso biomechanics of 3 sizes of adult volunteers (5th percentile female, 50th percentile male, and 95th percentile male) subjected to motorized shoulder belt tensioning in the static environment. There is a lack of volunteer data concerning the biomechanics of occupants subject to motorized precrash shoulder belt tensioning. Studies of torso repositioning by the air force for ejection seats are much too aggressive to be relevant to motorized systems. Low-level motorized shoulder belt tensioning is well tolerated by vehicle occupants but optimized performance by occupant size is unknown. Nineteen male and 6 female subjects were instrumented in a fixture designed to support the occupant leaning forward and apply seatbelt tension. The subjects were 5th percentile females, 50th percentile males, and 95th percentile males. Reflective markers were placed on the subjects to monitor torso kinematics during tensioning. Changes in spinal curvature were small during shoulder belt tensioning and the angular motion of the torso originated within 4.2 cm of the pelvis-femur junction or H-point. Torso repositioning and retraction timing was found to be: 54.3 degrees in 0.78 seconds for the 5th percentile female, 57.6 degrees in 0.95 seconds for the 50th percentile male, and 42.2 degrees in 0.92 seconds for the 95th percentile male. Occupant size has a significant effect on retraction time to reposition the torso during shoulder belt tensioning. Larger vehicle occupants require more time because of a slower retraction velocity. The results are sufficiently simple that a lumped-mass model can predict tensioning kinetics.

  6. The effect of vision on knee biomechanics during functional activities - A systematic review.

    PubMed

    Louw, Quinette; Gillion, Nadia; van Niekerk, Sjan-Mari; Morris, Linzette; Baumeister, Jochen

    2015-07-01

    The objective of this study was to assess the effect of occluded vision on lower limb kinematics and kinetics of the knee joint during functional tasks including drop landing (single or double leg), squatting (single or double leg), stepping down, cutting movement and hopping in healthy individuals, or individuals who had an ACL reconstruction or deficiency with no vision impairments. A systematic review was conducted. A systematic review was conducted and electronic databases were searched between March 2012 and April 2013 for eligible papers. Methodological quality of each study was assessed using the Downs and Black revised checklist. Six studies met the eligibility criteria and a wide variation in methodological approaches was reported. This small evidence base indicated equivocal evidence about the effect of vision on knee biomechanics in individuals with healthy and compromised somatosensory function post an ACL reconstruction or injury. Clinicians should consider innovative, individualised ACL rehabilitation strategies when prescribing exercises which involve visual occlusion. Further research to increase the relatively small evidence base for the effect of vision on knee biomechanics is warranted. Copyright © 2014 Sports Medicine Australia. All rights reserved.

  7. Comparative biomechanical effectiveness of over-the-counter devices for individuals with a flexible flatfoot secondary to forefoot varus.

    PubMed

    Hurd, Wendy J; Kavros, Steven J; Kaufman, Kenton R

    2010-11-01

    Evaluate effects of a new off-the-shelf insert on frontal plane foot biomechanics and compare effectiveness of the new and an existing off-the-shelf insert and a motion-control shoe in neutralizing frontal plane foot biomechanics. Descriptive. Biomechanics laboratory. Fifteen uninjured subjects with a flexible flatfoot secondary to forefoot varus. Three-dimensional kinematic and kinetic data were collected as subjects walked and jogged at their self-selected speed while wearing a motion-control running shoe, the shoe with a new off-the-shelf insert, and the shoe with an existing off-the-shelf insert. Frontal plane kinematics and rearfoot kinetics were evaluated during stance. Statistical analysis was performed using a repeated measures analysis of variance and Student-Newman-Keuls post hoc tests (α ≤ 0.05). The new insert and motion-control shoe placed the forefoot in a less-everted position than the existing off-the-shelf insert during walking. There were no differences in forefoot kinematics during jogging, nor were there differences in rearfoot motion during walking or jogging. The rearfoot eversion moment was significantly lower with the new off-the-shelf insert compared with the motion-control shoe and the existing insert during walking and jogging. A new off-the-shelf device is available that promotes more neutral frontal plane biomechanics, thus providing a theoretical rationale for using this device for injury prevention and treatment. The comparative biomechanical effectiveness of a motion-control shoe and the orthotic inserts may assist health care professionals in selecting a device to correct the flatfoot structure.

  8. Multi-objective optimization to predict muscle tensions in a pinch function using genetic algorithm

    NASA Astrophysics Data System (ADS)

    Bensghaier, Amani; Romdhane, Lotfi; Benouezdou, Fethi

    2012-03-01

    This work is focused on the determination of the thumb and the index finger muscle tensions in a tip pinch task. A biomechanical model of the musculoskeletal system of the thumb and the index finger is developed. Due to the assumptions made in carrying out the biomechanical model, the formulated force analysis problem is indeterminate leading to an infinite number of solutions. Thus, constrained single and multi-objective optimization methodologies are used in order to explore the muscular redundancy and to predict optimal muscle tension distributions. Various models are investigated using the optimization process. The basic criteria to minimize are the sum of the muscle stresses, the sum of individual muscle tensions and the maximum muscle stress. The multi-objective optimization is solved using a Pareto genetic algorithm to obtain non-dominated solutions, defined as the set of optimal distributions of muscle tensions. The results show the advantage of the multi-objective formulation over the single objective one. The obtained solutions are compared to those available in the literature demonstrating the effectiveness of our approach in the analysis of the fingers musculoskeletal systems when predicting muscle tensions.

  9. Lumbar annulus fibrosus biomechanical characterization in healthy children by ultrasound shear wave elastography.

    PubMed

    Vergari, Claudio; Dubois, Guillaume; Vialle, Raphael; Gennisson, Jean-Luc; Tanter, Mickael; Dubousset, Jean; Rouch, Philippe; Skalli, Wafa

    2016-04-01

    Intervertebral disc (IVD) is key to spine biomechanics, and it is often involved in the cascade leading to spinal deformities such as idiopathic scoliosis, especially during the growth spurt. Recent progress in elastography techniques allows access to non-invasive measurement of cervical IVD in adults; the aim of this study was to determine the feasibility and reliability of shear wave elastography in healthy children lumbar IVD. Elastography measurements were performed in 31 healthy children (6-17 years old), in the annulus fibrosus and in the transverse plane of L5-S1 or L4-L5 IVD. Reliability was determined by three experienced operators repeating measurements. Average shear wave speed in IVD was 2.9 ± 0.5 m/s; no significant correlations were observed with sex, age or body morphology. Intra-operator repeatability was 5.0 % while inter-operator reproducibility was 6.2 %. Intraclass correlation coefficient was higher than 0.9 for each operator. Feasibility and reliability of IVD shear wave elastography were demonstrated. The measurement protocol is compatible with clinical routine and the results show the method's potential to give an insight into spine deformity progression and early detection. • Intervertebral disc mechanical properties are key to spine biomechanics • Feasibility of shear wave elastography in children lumbar disc was assessed • Measurement was fast and reliable • Elastography could represent a novel biomarker for spine pathologies.

  10. Biomechanics-based in silico medicine: the manifesto of a new science.

    PubMed

    Viceconti, Marco

    2015-01-21

    In this perspective article we discuss the role of contemporary biomechanics in the light of recent applications such as the development of the so-called Virtual Physiological Human technologies for physiology-based in silico medicine. In order to build Virtual Physiological Human (VPH) models, computer models that capture and integrate the complex systemic dynamics of living organisms across radically different space-time scales, we need to re-formulate a vast body of existing biology and physiology knowledge so that it is formulated as a quantitative hypothesis, which can be expressed in mathematical terms. Once the predictive accuracy of these models is confirmed against controlled experiments and against clinical observations, we will have VPH model that can reliably predict certain quantitative changes in health status of a given patient, but also, more important, we will have a theory, in the true meaning this word has in the scientific method. In this scenario, biomechanics plays a very important role, biomechanics is one of the few areas of life sciences where we attempt to build full mechanistic explanations based on quantitative observations, in other words, we investigate living organisms like physical systems. This is in our opinion a Copernican revolution, around which the scope of biomechanics should be re-defined. Thus, we propose a new definition for our research domain "Biomechanics is the study of living organisms as mechanistic systems". Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. 34 CFR 200.18 - Annual measurable objectives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Annual measurable objectives. 200.18 Section 200.18 Education Regulations of the Offices of the Department of Education OFFICE OF ELEMENTARY AND SECONDARY EDUCATION, DEPARTMENT OF EDUCATION TITLE I-IMPROVING THE ACADEMIC ACHIEVEMENT OF THE DISADVANTAGED Improving...

  12. Moire measuring technology for three-dimensional profile of the object

    NASA Astrophysics Data System (ADS)

    Fu, Yanjun; Yang, Kuntao

    2006-02-01

    An optical system is designed to get projection of the transmission grating, the deformed grating is obtained on surface of the object. The image of the deformed grating is given by the lens, the reference grating is put on the place of the image, and then the moire fringe is obtained. The amplify principle of the moire fringe is used to measure the profile of the object. The optical principle of the projection is analyzed. And the relation between the phase and the height of object is deduced. From the different point of geometry optics and the physics opticsl, the optical system is analyzed, the factors that influence the image equality and the measuring result are obtained. So the betterment of improving the measuring precision is brought forward, and in the later information processing, because of the diffuse reflection, the image equality is not very well. In order to get a good image, the digital filter is used to filter the noise and smooth the image firstly. Then in order to improve the measure precision, the subdivision technology is applied. The Fourier transform profilometry and phase shifting technology is used in the calculation. A detail analyses is done both in time field and frequency field. And the method of improving the measuring precision is put forward. A good digital filter algorithm is brought forward in the Fourier transform profilometry. In the phase shifting technology, the detail formula of three-step and four-step is given. At last the phase that is relational with the high information of the object is get, but the phase is disconnected phase, after the unwrapping algorithm,the disconnected phase is changed to be the continuous phase. Taking use of the relation between the phase and height, the height is obtained. Then the three-dimensional profile of the measured object can be reconstructed. The system is very convenient for non-contact measure of profile of some objects.

  13. Perspectives on Sharing Models and Related Resources in Computational Biomechanics Research.

    PubMed

    Erdemir, Ahmet; Hunter, Peter J; Holzapfel, Gerhard A; Loew, Leslie M; Middleton, John; Jacobs, Christopher R; Nithiarasu, Perumal; Löhner, Rainlad; Wei, Guowei; Winkelstein, Beth A; Barocas, Victor H; Guilak, Farshid; Ku, Joy P; Hicks, Jennifer L; Delp, Scott L; Sacks, Michael; Weiss, Jeffrey A; Ateshian, Gerard A; Maas, Steve A; McCulloch, Andrew D; Peng, Grace C Y

    2018-02-01

    The role of computational modeling for biomechanics research and related clinical care will be increasingly prominent. The biomechanics community has been developing computational models routinely for exploration of the mechanics and mechanobiology of diverse biological structures. As a result, a large array of models, data, and discipline-specific simulation software has emerged to support endeavors in computational biomechanics. Sharing computational models and related data and simulation software has first become a utilitarian interest, and now, it is a necessity. Exchange of models, in support of knowledge exchange provided by scholarly publishing, has important implications. Specifically, model sharing can facilitate assessment of reproducibility in computational biomechanics and can provide an opportunity for repurposing and reuse, and a venue for medical training. The community's desire to investigate biological and biomechanical phenomena crossing multiple systems, scales, and physical domains, also motivates sharing of modeling resources as blending of models developed by domain experts will be a required step for comprehensive simulation studies as well as the enhancement of their rigor and reproducibility. The goal of this paper is to understand current perspectives in the biomechanics community for the sharing of computational models and related resources. Opinions on opportunities, challenges, and pathways to model sharing, particularly as part of the scholarly publishing workflow, were sought. A group of journal editors and a handful of investigators active in computational biomechanics were approached to collect short opinion pieces as a part of a larger effort of the IEEE EMBS Computational Biology and the Physiome Technical Committee to address model reproducibility through publications. A synthesis of these opinion pieces indicates that the community recognizes the necessity and usefulness of model sharing. There is a strong will to facilitate

  14. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation

    PubMed Central

    Kang, K-T.; Koh, Y-G.; Son, J.; Kwon, O-R.; Baek, C.; Jung, S. H.

    2016-01-01

    Objectives Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Materials and Methods Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Results Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. Conclusions These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552–559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1. PMID:28094763

  15. Corneal Biomechanical Changes Following Toric Soft Contact Lens Wear.

    PubMed

    Radaie-Moghadam, Somayeh; Hashemi, Hassan; Jafarzadehpur, Ebrahim; Yekta, Abbas Ali; Khabazkhoob, Mehdi

    2016-01-01

    To determine the effect of using toric soft contact lenses on corneal biomechanical properties. We enrolled 33 healthy patients with mean age of 23.18 ± 4.06 and minimal cylinder power of 1 D (-1.98 ± 0.808 SD) and negative history of contact lens use; keratoconic patients were excluded from the study. Toric soft contact lenses (BIOFINITY, Comfilcon A, Coopervision, Southampton, UK) were fitted in all participants. The Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, New York, USA) was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), and the Pentacam HR (Oculus, Inc., Lynnwood, WA, USA) was used to measure central corneal thickness (CCT) and mean keratometry (K mean) before and one week, one month, and three months after using the toric soft contact lenses. CH and CRF were decreased significantly one month after using the contact lens; mean CH decreased from 9.99 ± 1.44 to 9.59 ± 1.54 mmHg, and mean CRF decreased from 9.96 ± 1.71 to 9.63 ± 1.73 mmHg (P = 0.013 and P = 0.017, respectively). Mean CCT and K mean did not show a significant change during the period of toric soft contact lens use. CH and CRF decreased significantly one month after fitting toric soft contact lenses while CCT and Kmean did not change significantly. Corneal biomechanical parameters may alter with toric soft contact lens use and such changes may have implications with long-term use such lenses.

  16. Supplementing biomechanical modeling with EMG analysis

    NASA Technical Reports Server (NTRS)

    Lewandowski, Beth; Jagodnik, Kathleen; Crentsil, Lawton; Humphreys, Bradley; Funk, Justin; Gallo, Christopher; Thompson, William; DeWitt, John; Perusek, Gail

    2016-01-01

    It is well established that astronauts experience musculoskeletal deconditioning when exposed to microgravity environments for long periods of time. Spaceflight exercise is used to counteract these effects, and the Advanced Resistive Exercise Device (ARED) on the International Space Station (ISS) has been effective in minimizing musculoskeletal losses. However, the exercise devices of the new exploration vehicles will have requirements of limited mass, power and volume. Because of these limitations, there is a concern that the exercise devices will not be as effective as ARED in maintaining astronaut performance. Therefore, biomechanical modeling is being performed to provide insight on whether the small Multi-Purpose Crew Vehicle (MPCV) device, which utilizes a single-strap design, will provide sufficient physiological loading to maintain musculoskeletal performance. Electromyography (EMG) data are used to supplement the biomechanical model results and to explore differences in muscle activation patterns during exercises using different loading configurations.

  17. Biomechanical, physiological and psychophysical evaluations of clean room boots.

    PubMed

    Lin, Chih-Long; Wang, Mao-Jiun J; Drury, Colin G

    2007-04-01

    The purpose of this study was to evaluate the significance of boot sole properties on reducing fatigue, to evaluate the effects of load carrying and walking (over a 1 h period) on biomechanical, physiological and psychophysical responses, and to investigate the correlations between the measurements. The results indicated that elasticity and shock absorption of the boot had significant effects on outcome variables. Significant load effects were seen in most measurements. All of the significant time period effects gave strong regressions, with no R2 value less than 0.983. The findings of this study provide useful information for the selection and design of clean room boots as well as for job design for load carrying tasks in the clean room environment.

  18. Biomechanical investigation of head impacts in football

    PubMed Central

    Withnall, C; Shewchenko, N; Gittens, R; Dvorak, J

    2005-01-01

    Objectives: This study sought to measure the head accelerations induced from upper extremity to head and head to head impact during the game of football and relate this to the risk of mild traumatic brain injury using the Head Impact Power (HIP) index. Furthermore, measurement of upper neck forces and torques will indicate the potential for serious neck injury. More stringent rules or punitive sanctions may be warranted for intentional impact by the upper extremity or head during game play. Methods: Game video of 62 cases of head impact (38% caused by the upper extremity and 30% by the head of the opposing player) was provided by F-MARC. Video analysis revealed the typical impact configurations and representative impact speeds. Upper extremity impacts of elbow strike and lateral hand strike were re-enacted in the laboratory by five volunteer football players striking an instrumented Hybrid III pedestrian model crash test manikin. Head to head impacts were re-enacted using two instrumented test manikins. Results: Elbow to head impacts (1.7–4.6 m/s) and lateral hand strikes (5.2–9.3 m/s) resulted in low risk of concussion (<5%) and severe neck injury (<5%). Head to head impacts (1.5–3.0 m/s) resulted in high concussion risk (up to 67%) but low risk of severe neck injury (<5%). Conclusion: The laboratory simulations suggest little risk of concussion based on head accelerations and maximum HIP. There is no biomechanical justification for harsher penalties in this regard. However, deliberate use of the head to impact another player's head poses a high risk of concussion, and justifies a harsher position by regulatory bodies. In either case the risk of serious neck injury is very low. PMID:16046356

  19. Biomechanics Associated with Patellofemoral Pain and ACL Injuries in Sports.

    PubMed

    Weiss, Kaitlyn; Whatman, Chris

    2015-09-01

    Knee injuries are prevalent among a variety of competitive sports and can impact an athlete's ability to continue to participate in their sport or, in the worst case, end an athlete's career. The aim was to evaluate biomechanics associated with both patellofemoral pain syndrome (PFPS) and anterior cruciate ligament (ACL) injuries (in sports involving landing, change in direction, or rapid deceleration) across the three time points frequently reported in the literature: pre-injury, at the time of injury, and following injury. A search of the literature was conducted for research evaluating biomechanics associated with ACL injury and PFPS. The Web of Science, SPORTDiscus, EBSCO, PubMed, and CINAHL databases, to March 2015, were searched, and journal articles focused on ACL injuries and PFPS in sports that met the inclusion criteria were reviewed. The search methodology was created with the intent of extracting case-control, case, and cohort studies of knee injury in athletic populations. The search strategy was restricted to only full-text articles published in English. These articles were included in the review if they met all of the required selection criteria. The following inclusion criteria were used: (1) The study must report lower extremity biomechanics in one of the following settings: (a) a comparison of currently injured and uninjured participants, (b) a prospective study evaluating risk factors for injury, or (c) a study reporting on the injury event itself. (2) The study must include only currently active participants who were similar at baseline (i.e. healthy, high school level basketball players currently in-season) and include biomechanical analysis of either landing, change in direction, or rapid deceleration. (3) The study must include currently injured participants. The studies were graded on the basis of quality, which served as an indication of risk of bias. An adapted version of the 'Strengthening the Reporting of Observational Studies in

  20. Finding the Density of Objects without Measuring Mass and Volume

    ERIC Educational Resources Information Center

    Mumba, Frackson; Tsige, Mesfin

    2007-01-01

    A simple method based on the moment of forces and Archimedes' principle is described for finding density without measuring the mass and volume of an object. The method involves balancing two unknown objects of masses M[subscript 1] and M[subscript 2] on each side of a pivot on a metre rule and measuring their corresponding moment arms. The object…

  1. Biomechanical aspects of gravitational training of the astronauts before the flight.

    PubMed

    Laputin, A N

    1997-07-01

    Researchers tested a hypothesis that astronauts can become more proficient in training for tasks during space flight by training in a high gravity suit. Computer image analysis of movements, tensodynamography, and myotonometry were used to analyze movement in the hypergravity suit, muscle response, and other biomechanical factors. Results showed that training in the hypergravity suit improved the biomechanics of motor performance.

  2. 3-d finite element model development for biomechanics: a software demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollerbach, K.; Hollister, A.M.; Ashby, E.

    1997-03-01

    Finite element analysis is becoming an increasingly important part of biomechanics and orthopedic research, as computational resources become more powerful, and data handling algorithms become more sophisticated. Until recently, tools with sufficient power did not exist or were not accessible to adequately model complicated, three-dimensional, nonlinear biomechanical systems. In the past, finite element analyses in biomechanics have often been limited to two-dimensional approaches, linear analyses, or simulations of single tissue types. Today, we have the resources to model fully three-dimensional, nonlinear, multi-tissue, and even multi-joint systems. The authors will present the process of developing these kinds of finite element models,more » using human hand and knee examples, and will demonstrate their software tools.« less

  3. Objective Measurement of Emerging Affective Traits in Preschool Children.

    ERIC Educational Resources Information Center

    Adkins, Dorothy C.

    An objective measure of motivation to achieve for preschool children called Gumpgookies is described. It is an objective-projective technique that requires choice between two alternate types of behavior portrayed in pictures and accompanying verbal descriptions. Gumpgookies are amoeba-like creatures who behave in ways intended to show differences…

  4. Whole-globe biomechanics using high-field MRI.

    PubMed

    Voorhees, Andrew P; Ho, Leon C; Jan, Ning-Jiun; Tran, Huong; van der Merwe, Yolandi; Chan, Kevin; Sigal, Ian A

    2017-07-01

    The eye is a complex structure composed of several interconnected tissues acting together, across the whole globe, to resist deformation due to intraocular pressure (IOP). However, most work in the ocular biomechanics field only examines the response to IOP over smaller regions of the eye. We used high-field MRI to measure IOP induced ocular displacements and deformations over the whole globe. Seven sheep eyes were obtained from a local abattoir and imaged within 48 h using MRI at multiple levels of IOP. IOP was controlled with a gravity perfusion system and a cannula inserted into the anterior chamber. T2-weighted imaging was performed to the eyes serially at 0 mmHg, 10 mmHg, 20 mmHg and 40 mmHg of IOP using a 9.4 T MRI scanner. Manual morphometry was conducted using 3D visualization software to quantify IOP-induced effects at the globe scale (e.g. axial length and equatorial diameters) or optic nerve head scale (e.g. canal diameter, peripapillary sclera bowing). Measurement sensitivity analysis was conducted to determine measurement precision. High-field MRI revealed an outward bowing of the posterior sclera and anterior bulging of the cornea due to IOP elevation. Increments in IOP from 10 to 40 mmHg caused measurable increases in axial length in 6 of 7 eyes of 7.9 ± 5.7% (mean ± SD). Changes in equatorial diameter were minimal, 0.4 ± 1.2% between 10 and 40 mmHg, and in all cases less than the measurement sensitivity. The effects were nonlinear, with larger deformations at normal IOPs (10-20 mmHg) than at elevated IOPs (20-40 mmHg). IOP also caused measurable increases in the nasal-temporal scleral canal diameter of 13.4 ± 9.7% between 0 and 20 mmHg, but not in the superior-inferior diameter. This study demonstrates that high-field MRI can be used to visualize and measure simultaneously the effects of IOP over the whole globe, including the effects on axial length and equatorial diameter, posterior sclera displacement and bowing, and even

  5. Feeding biomechanics of the cownose ray, Rhinoptera bonasus, over ontogeny

    PubMed Central

    Kolmann, Matthew A; Huber, Daniel R; Motta, Philip J; Grubbs, R Dean

    2015-01-01

    Growth affects the performance of structure, so the pattern of growth must influence the role of a structure and an organism. Because animal performance is linked to morphological specialization, ontogenetic change in size may influence an organism's biological role. High bite force generation is presumably selected for in durophagous taxa. Therefore, these animals provide an excellent study system for investigating biomechanical consequences of growth on performance. An ontogenetic series of 27 cownose rays (Rhinoptera bonasus) were dissected in order to develop a biomechanical model of the feeding mechanism, which was then compared with bite forces measured from live rays. Mechanical advantage of the feeding apparatus was generally conserved throughout ontogeny, while an increase in the mass and cross-sectional area of the jaw adductors resulted in allometric gains in bite force generation. Of primary importance to forceful biting in this taxon is the use of a fibrocartilaginous tendon associated with the insertion of the primary jaw adductor division. This tendon may serve to redirect muscle forces anteriorly, transmitting them within the plane of biting. Measured bite forces obtained through electrostimulation of the jaw adductors in live rays were higher than predicted, possibly due to differences in specific tension of actual batoid muscle and that used in the model. Mass-specific bite forces in these rays are the highest recorded for elasmobranchs. Cownose rays exemplify a species that, through allometric growth of bite performance and morphological novelties, have expanded their ecological performance over ontogeny. PMID:26183820

  6. Biomechanical differences between unilateral and bilateral landings from a jump: gender differences.

    PubMed

    Pappas, Evangelos; Hagins, Marshall; Sheikhzadeh, Ali; Nordin, Margareta; Rose, Donald

    2007-07-01

    To determine the effect of landing type (unilateral vs. bilateral) and gender on the biomechanics of drop landings in recreational athletes. This study used a repeated measures design to compare bilateral and unilateral landings in male and female athletes. A repeated measures multivariate analysis of variance (type of landing*gender) was performed on select variables. Biomechanics laboratory. Sixteen female and 16 male recreational athletes. Kinetic, kinematic, and electromyographic (EMG) data were collected on participants while performing bilateral and unilateral landings from a 40-cm platform. Compared to bilateral landings, subjects performed unilateral landings with increased knee valgus, decreased knee flexion at initial contact, decreased peak knee flexion, decreased relative hip adduction, and increased normalized EMG of the rectus femoris, medial hamstrings, lateral hamstrings, and medial gastrocnemius (P < 0.005). During both types of landing, females landed with increased knee valgus and normalized vertical ground reaction force (VGRF) compared to males (P < 0.009), however, the interaction of landing type*gender was not significant (P = 0.29). Compared to bilateral landings, male and female recreational athletes performed unilateral landings with significant differences in knee kinematic and EMG variables. Female athletes landed with increased knee valgus and VGRF compared to males during both types of landing.

  7. [Biomechanics study during march with different military equipment of equal carrying load].

    PubMed

    Lang, Y Y

    1992-03-01

    The purpose of the study is to select the best military equipment of equal carrying load by the index of biomechanics. Six healthy young men whose age varied between 19 and 25 years were volunteered, in the experiment. They were required to march 1.5 h, carried with different military equipment of equal weight, 25 kg, at a speed of 5 km/h. The centre of gravity of the body and its kinesic parameters were measured before and after the march. The frequency and length of pace were measured during the march. The results of the study indicated that the displacement of the body's centre of gravity carrying equipment I was the most evident, whereas the least displacement of centre of gravity of the body was that carrying equipment II. The frequency of pace during the march was reduced in all three carrying different kinds of equipment, the most evident being that carrying equipment I; the length of pace became bigger with those carrying equipment II and III; the speed of pace was decelerated using equipment I, but it was quickened with equipment II. The change of kinesic parameters have no significant difference among the three. In summary; equipment II conforms best to biomechanical principles, whereas equipment I is the worst.

  8. Biomechanical consequences of subtalar joint arthroereisis in treating posterior tibial tendon dysfunction: a theoretical analysis using finite element analysis.

    PubMed

    Wong, Duo Wai-Chi; Wang, Yan; Chen, Tony Lin-Wei; Leung, Aaron Kam-Lun; Zhang, Ming

    2017-11-01

    Subtalar joint arthroereisis (SJA) has been introduced to control the hyperpronation in cases of flatfoot. The objective of this study is to evaluate the biomechanical consequence of SJA to restore the internal stress and load transfer to the intact state from the attenuated biomechanical condition induced by posterior tibial tendon dysfunction (PTTD). A three-dimensional finite element model of the foot and ankle complex was constructed based on clinical images of a healthy female (age 28 years, height 165 cm, body mass 54 kg). The boundary and loading condition during walking was acquired from the gait experiment of the model subject. Five sets of simulations (conditions) were completed: intact condition, mild PTTD, severe PTTD, mild PTTD with SJA, severe PTTD with SJA. The maximum von Mises stress of the metatarsal shafts and the load transfer along the midfoot during stance were analyzed. Generally, SJA deteriorated the joint force of the medial cuneonavicular and calcaneocuboid joints during late stance, while that of the metatarsocuneiform joints during early stance were over-corrected. Only the calcaneocuboid joint force at 45% stance demonstrated a trend of improvement. Besides, SJA exaggerated the increased stress of the metatarsals compared to the PTTD conditions, except that of the first metatarsal. Our study did not support the hypothesis that SJA can restore the internal load transfer and midfoot stress. SJA cannot compensate the salvage of midfoot stability attributed by PTTD and could be biomechanically insufficient to restore the biomechanical environment. Additional procedures such as orthotic intervention may be necessary.

  9. Biomechanical research in dance: a literature review.

    PubMed

    Krasnow, Donna; Wilmerding, M Virginia; Stecyk, Shane; Wyon, Matthew; Koutedakis, Yiannis

    2011-03-01

    The authors reviewed the literature, published from 1970 through December 2009, on biomechanical research in dance. To identify articles, the authors used search engines, including PubMed and Web of Science, five previous review articles, the Dance Medicine and Science Bibliography, and reference lists of theses, dissertations, and articles being reviewed. Any dance research articles (English language) involving the use of electromyography, forceplates, motion analysis using photography, cinematography or videography, and/or physics analysis were included. A total of 89 papers, theses/dissertations, and abstracts were identified and reviewed, grouped by the movement concept or specialized movements being studied: alignment (n = 8), plié (8), relevé (8), passé (3), degagé (3), développé (7), rond de jambe (3), grand battement (4), arm movements (1), forward stepping (3), turns (6), elevation work (28), falls (1), and dance-specific motor strategies (6). Several recurring themes emerged from these studies: that elite dancers demonstrate different and superior motor strategies than novices or nondancers; that dancers perform differently when using a barre as opposed to without a barre, both in terms of muscle activation patterns and weight shift strategies; that while skilled dancers tend to be more consistent across multiple trials of a task, considerable variability is seen among participants, even when matched for background, years of training, body type, and other variables; and that dance teachers recommend methods of achieving movement skills that are inconsistent with optimal biomechanical function, as well as inconsistent with strategies employed by elite dancers. Measurement tools and the efficacy of study methodologies are also discussed.

  10. Sex Differences in Landing Biomechanics and Postural Stability During Adolescence: A Systematic Review with Meta-Analyses.

    PubMed

    Holden, Sinéad; Boreham, Colin; Delahunt, Eamonn

    2016-02-01

    The adolescent 'growth spurt' results in rapid growth of the skeletal system. It has been theorised that absence of a concomitant increase in muscular adaptations in female athletes may predispose them to an increased risk of anterior cruciate ligament injuries. To determine if sex differences exist in landing biomechanics and postural stability of adolescent athletes; with a further objective of determining if such differences are propagated during adolescence. The following databases were searched: MEDLINE, EMBASE, CINAHL, PEDro, PubMed, SPORTDiscus and Web of Science. Research papers were identified by including search terms for neuromuscular control, lower limb and pubertal development. Studies were required to be written in English; report on biomechanical analyses; include landing or postural control tasks; be cross-sectional or longitudinal; and include healthy adolescent/pubertal subjects. A modified version of the Strengthening the Reporting of Observational studies in Epidemiology checklist was used to rate methodological quality. Meta-analyses were performed when more than one study reported on an outcome measure. Sixteen articles were included. The overall methodological quality of evaluated studies was low (mean score = 5.75/10 points). Adolescent females exhibited increased knee valgus with increasing maturity. There was no consensus on sex differences in postural stability. With increasing maturation, females are characterized by increased knee valgus during landing tasks. To date, no research has longitudinally investigated postural stability development during adolescence in females, despite the importance of postural control training in injury prevention programmes. Therefore, further research on this topic is warranted.

  11. Effects of repeated ankle stretching on calf muscle-tendon and ankle biomechanical properties in stroke survivors

    PubMed Central

    Gao, Fan; Ren, Yupeng; Roth, Elliot J.; Harvey, Richard; Zhang, Li-Qun

    2011-01-01

    Background The objective of this study was to investigate changes in active and passive biomechanical properties of the calf muscle-tendon unit induced by controlled ankle stretching in stroke survivors. Methods Ten stroke survivors with ankle spasticity/contracture and ten healthy control subjects received intervention of 60-min ankle stretching. Joint biomechanical properties including resistance torque, stiffness and index of hysteresis were evaluated pre- and post-intervention. Achilles tendon length was measured using ultrasonography. The force output of the triceps surae muscles was characterized via the torque-angle relationship, by stimulating the calf muscles at a controlled intensity across different ankle positions. Findings Compared to healthy controls, the ankle position corresponding to the peak torque of the stroke survivors was shifted towards plantar flexion (P<0.001). Stroke survivors showed significantly higher resistance torques and joint stiffness (P<0.05), and these higher resistances were reduced significantly after the stretching intervention, especially in dorsiflexion (P = 0.013). Stretching significantly improved the force output of the impaired calf muscles in stroke survivors under matched stimulations (P<0.05). Ankle range of motion was also increased by stretching (P<0.001). Interpretation At the joint level, repeated stretching loosened the ankle joint with increased passive joint range of motion and decreased joint stiffness. At the muscle-tendon level, repeated stretching improved calf muscle force output, which might be associated with decreased muscle fascicle stiffness, increased fascicle length and shortening of the Achilles tendon. The study provided evidence of improvement in muscle tendon properties through stretching intervention. PMID:21211873

  12. The influence of hand positions on biomechanical injury risk factors at the wrist joint during the round-off skills in female gymnastics.

    PubMed

    Farana, Roman; Jandacka, Daniel; Uchytil, Jaroslav; Zahradnik, David; Irwin, Gareth

    2017-01-01

    The aim of this study was to examine the biomechanical injury risk factors at the wrist, including joint kinetics, kinematics and stiffness in the first and second contact limb for parallel and T-shape round-off (RO) techniques. Seven international-level female gymnasts performed 10 trials of the RO to back handspring with parallel and T-shape hand positions. Synchronised kinematic (3D motion analysis system; 247 Hz) and kinetic (two force plates; 1235 Hz) data were collected for each trial. A two-way repeated measure analysis of variance (ANOVA) assessed differences in the kinematic and kinetic parameters between the techniques for each contact limb. The main findings highlighted that in both the RO techniques, the second contact limb wrist joint is exposed to higher mechanical loads than the first contact limb demonstrated by increased axial compression force and loading rate. In the parallel technique, the second contact limb wrist joint is exposed to higher axial compression load. Differences between wrist joint kinetics highlight that the T-shape technique may potentially lead to reducing these bio-physical loads and consequently protect the second contact limb wrist joint from overload and biological failure. Highlighting the biomechanical risk factors facilitates the process of technique selection making more objective and safe.

  13. Generally objective measurement of human temperature and reading ability: some corollaries.

    PubMed

    Stenner, A Jackson; Stone, Mark

    2010-01-01

    We argue that a goal of measurement is general objectivity: point estimates of a person's measure (height, temperature, and reader ability) should be independent of the instrument and independent of the sample in which the person happens to find herself. In contrast, Rasch's concept of specific objectivity requires only differences (i.e., comparisons) between person measures to be independent of the instrument. We present a canonical case in which there is no overlap between instruments and persons: each person is measured by a unique instrument. We then show what is required to estimate measures in this degenerate case. The canonical case encourages a simplification and reconceptualization of validity and reliability. Not surprisingly, this reconceptualization looks a lot like the way physicists and chemometricians think about validity and measurement error. We animate this presentation with a technology that blurs the distinction between instruction, assessment, and generally objective measurement of reader ability. We encourage adaptation of this model to health outcomes measurement.

  14. Direct biomechanical modeling of trabecular bone using a nonlinear manifold-based volumetric representation

    NASA Astrophysics Data System (ADS)

    Jin, Dakai; Lu, Jia; Zhang, Xiaoliu; Chen, Cheng; Bai, ErWei; Saha, Punam K.

    2017-03-01

    Osteoporosis is associated with increased fracture risk. Recent advancement in the area of in vivo imaging allows segmentation of trabecular bone (TB) microstructures, which is a known key determinant of bone strength and fracture risk. An accurate biomechanical modelling of TB micro-architecture provides a comprehensive summary measure of bone strength and fracture risk. In this paper, a new direct TB biomechanical modelling method using nonlinear manifold-based volumetric reconstruction of trabecular network is presented. It is accomplished in two sequential modules. The first module reconstructs a nonlinear manifold-based volumetric representation of TB networks from three-dimensional digital images. Specifically, it starts with the fuzzy digital segmentation of a TB network, and computes its surface and curve skeletons. An individual trabecula is identified as a topological segment in the curve skeleton. Using geometric analysis, smoothing and optimization techniques, the algorithm generates smooth, curved, and continuous representations of individual trabeculae glued at their junctions. Also, the method generates a geometrically consistent TB volume at junctions. In the second module, a direct computational biomechanical stress-strain analysis is applied on the reconstructed TB volume to predict mechanical measures. The accuracy of the method was examined using micro-CT imaging of cadaveric distal tibia specimens (N = 12). A high linear correlation (r = 0.95) between TB volume computed using the new manifold-modelling algorithm and that directly derived from the voxel-based micro-CT images was observed. Young's modulus (YM) was computed using direct mechanical analysis on the TB manifold-model over a cubical volume of interest (VOI), and its correlation with the YM, computed using micro-CT based conventional finite-element analysis over the same VOI, was examined. A moderate linear correlation (r = 0.77) was observed between the two YM measures. This

  15. Smoothing spline analysis of variance models: A new tool for the analysis of cyclic biomechanical data.

    PubMed

    Helwig, Nathaniel E; Shorter, K Alex; Ma, Ping; Hsiao-Wecksler, Elizabeth T

    2016-10-03

    Cyclic biomechanical data are commonplace in orthopedic, rehabilitation, and sports research, where the goal is to understand and compare biomechanical differences between experimental conditions and/or subject populations. A common approach to analyzing cyclic biomechanical data involves averaging the biomechanical signals across cycle replications, and then comparing mean differences at specific points of the cycle. This pointwise analysis approach ignores the functional nature of the data, which can hinder one׳s ability to find subtle differences between experimental conditions and/or subject populations. To overcome this limitation, we propose using mixed-effects smoothing spline analysis of variance (SSANOVA) to analyze differences in cyclic biomechanical data. The SSANOVA framework makes it possible to decompose the estimated function into the portion that is common across groups (i.e., the average cycle, AC) and the portion that differs across groups (i.e., the contrast cycle, CC). By partitioning the signal in such a manner, we can obtain estimates of the CC differences (CCDs), which are the functions directly describing group differences in the cyclic biomechanical data. Using both simulated and experimental data, we illustrate the benefits of using SSANOVA models to analyze differences in noisy biomechanical (gait) signals collected from multiple locations (joints) of subjects participating in different experimental conditions. Using Bayesian confidence intervals, the SSANOVA results can be used in clinical and research settings to reliably quantify biomechanical differences between experimental conditions and/or subject populations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. A numerical framework for studying the biomechanical behavior of abdominal aortic aneurysm

    NASA Astrophysics Data System (ADS)

    Jalalahmadi, Golnaz; Linte, Cristian; Helguera, María.

    2017-03-01

    Abdominal aortic aneurysm (AAA) is known as a leading cause of death in the United States. AAA is an abnormal dilation of the aorta, which usually occurs below the renal arteries and causes an expansion at least 1.5 times its normal diameter. It has been shown that biomechanical parameters of the aortic tissue coupled with a set of specific geometric parameters characterizing the vessel expansion, affect the risk of aneurysm rupture. Here, we developed a numerical framework that incorporates both biomechanical and geometrical factors to study the behavior of abdominal aortic aneurysm. Our workflow enables the extraction of the aneurysm geometry from both clinical quality, as well as low-resolution MR images. We used a two-parameter, hyper-elastic, isotropic, incompressible material to model the vessel tissue. Our numerical model was tested using both synthetic and mouse data and we evaluated the effects of the geometrical and biomechanical properties on the developed peak wall stress. In addition, we performed several parameter sensitivity studies to investigate the effect of different factors affecting the AAA and its behavior and rupture. Lastly, relationships between different geometrical and biomechanical parameters and peak wall stress were determined. These studies help us better understand vessel tissue response to various loading, geometry and biomechanics conditions, and we plan to further correlate these findings with the pathophysiological conditions from a patient population diagnosed with abdominal aortic aneurysms.

  17. Biomechanical Indices for Rupture Risk Estimation in Abdominal Aortic Aneurysms.

    PubMed

    Leemans, Eva L; Willems, Tineke P; van der Laan, Maarten J; Slump, Cornelis H; Zeebregts, Clark J

    2017-04-01

    To review the use of biomechanical indices for the estimation of abdominal aortic aneurysm (AAA) rupture risk, emphasizing their potential use in a clinical setting. A search of the PubMed, Embase, Scopus, and Compendex databases was made up to June 2015 to identify articles involving biomechanical analysis of AAA rupture risk. Outcome variables [aneurysm diameter, peak wall stress (PWS), peak wall shear stress (PWSS), wall strain, peak wall rupture index (PWRI), and wall stiffness] were compared for asymptomatic intact AAAs vs symptomatic or ruptured AAAs. For quantitative analysis of the pooled data, a random effects model was used to calculate the standard mean differences (SMDs) with the 95% confidence interval (CI) for the biomechanical indices. The initial database searches yielded 1894 independent articles of which 19 were included in the analysis. The PWS was significantly higher in the symptomatic/ruptured group, with a SMD of 1.11 (95% CI 0.93 to 1.26, p<0.001). Likewise, the PWRI was significantly higher in the ruptured or symptomatic group, with a SMD of 1.15 (95% CI 0.30 to 2.01, p=0.008). After adjustment for the aneurysm diameter, the PWS remained higher in the ruptured or symptomatic group, with a SMD of 0.85 (95% CI 0.46 to 1.23, p<0.001). Less is known of the wall shear stress and wall strain indices, as too few studies were available for analysis. Biomechanical indices are a promising tool in the assessment of AAA rupture risk as they incorporate several factors, including geometry, tissue properties, and patient-specific risk factors. However, clinical implementation of biomechanical AAA assessment remains a challenge owing to a lack of standardization.

  18. Fiber Bragg grating applications in biomechanics

    NASA Astrophysics Data System (ADS)

    Kalinowski, Hypolito José

    2008-04-01

    Fibre Bragg gratings are promising sensors for medical and bioengineering applications, mainly because of their small dimensions and chemical inertness. Although few examples of such applications are published up to date, we present results that show the expected potential for FBG sensor applications in biomechanical engineering.

  19. Biomechanical evaluation of bone screw fixation with a novel bone cement.

    PubMed

    Juvonen, Tiina; Nuutinen, Juha-Pekka; Koistinen, Arto P; Kröger, Heikki; Lappalainen, Reijo

    2015-07-30

    Bone cement augmentation is commonly used to improve the fixation stability of orthopaedic implants in osteoporotic bone. The aim of this study was to evaluate the effect of novel bone cements on the stability of bone screw fixation by biomechanical testing and to compare them with a conventional Simplex(®)P bone cement and requirements of the standards. Basic biomechanical properties were compared with standard tests. Adhesion of bone cements were tested with polished, glass blasted and corundum blasted stainless steel surfaces. Screw pullout testing with/without cement was carried out using a synthetic bone model and cancellous and cortical bone screws. All the tested bone cements fulfilled the requirements of the standard for biomechanical properties and improved the screw fixation stability. Even a threefold increase in shear and tensile strength was achieved with increasing surface roughness. The augmentation improved the screw pullout force compared to fixation without augmentation, 1.2-5.7 times depending on the cement and the screw type. The good biomechanical properties of novel bone cement for osteoporotic bone were confirmed by experimental testing. Medium viscosity of the bone cements allowed easy handling and well-controlled penetration of bone cement into osteoporotic bone. By proper parameters and procedures it is possible to achieve biomechanically stable fixation in osteoporotic bone. Based on this study, novel biostable bone cements are very potential biomaterials to enhance bone screw fixation in osteoporotic bone. Novel bone cement is easy to use without hand mixing using a dual syringe and thus makes it possibility to use it as required during the operation.

  20. Personal Career Orientation. Performance Objectives. Criterion Measures. Home Economics.

    ERIC Educational Resources Information Center

    Allen, Alveta; And Others

    Several intermediate performance objectives and corresponding criterion measures are listed for each of six terminal objectives for a personal career orientation course for seventh grade students. This 6- to 9-week course is designed to acquaint the student with personal qualities and characteristics necessary for success in the world of work.…

  1. Cervical spondylosis anatomy: pathophysiology and biomechanics.

    PubMed

    Shedid, Daniel; Benzel, Edward C

    2007-01-01

    Cervical spondylosis is the most common progressive disorder in the aging cervical spine. It results from the process of degeneration of the intervertebral discs and facet joints of the cervical spine. Biomechanically, the disc and the facets are the connecting structures between the vertebrae for the transmission of external forces. They also facilitate cervical spine mobility. Symptoms related to myelopathy and radiculopathy are caused by the formation of osteophytes, which compromise the diameter of the spinal canal. This compromise may also be partially developmental. The developmental process, together with the degenerative process, may cause mechanical pressure on the spinal cord at one or multiple levels. This pressure may produce direct neurological damage or ischemic changes and, thus, lead to spinal cord disturbances. A thorough understanding of the biomechanics, the pathology, the clinical presentation, the radiological evaluation, as well as the surgical indications of cervical spondylosis, is essential for the management of patients with cervical spondylosis.

  2. Application of biomechanics to tendon transfers.

    PubMed

    Hoard, A S; Bell-Krotoski, J A; Mathews, R

    1995-01-01

    This article has focused on considerations important in the application of biomechanics to tendon transfers and has used an example protocol. Different surgeries require different protocols. What is most important is that specific protocols are used, and that they are both safe and effective. The communication among the therapist, surgeon, and patient is essential with the use of any protocol. As Brand has stated, "A hand is a very personal thing. It is the interface between the patient and his or her world. It is an emblem of strength, beauty, skill, sexuality, and sensibility. When it is damaged it becomes a symbol of the vulnerability of the whole person." For the patient who has damage from nerve palsy, paralysis, or injury resulting in a dysfunctional hand, a tendon transfer procedure may prove to be a viable option to restore balance and function, especially if the biomechanics of deformity and correction are considered.

  3. Assessing ADHD symptoms in children and adults: evaluating the role of objective measures.

    PubMed

    Emser, Theresa S; Johnston, Blair A; Steele, J Douglas; Kooij, Sandra; Thorell, Lisa; Christiansen, Hanna

    2018-05-18

    Diagnostic guidelines recommend using a variety of methods to assess and diagnose ADHD. Applying subjective measures always incorporates risks such as informant biases or large differences between ratings obtained from diverse sources. Furthermore, it has been demonstrated that ratings and tests seem to assess somewhat different constructs. The use of objective measures might thus yield valuable information for diagnosing ADHD. This study aims at evaluating the role of objective measures when trying to distinguish between individuals with ADHD and controls. Our sample consisted of children (n = 60) and adults (n = 76) diagnosed with ADHD and matched controls who completed self- and observer ratings as well as objective tasks. Diagnosis was primarily based on clinical interviews. A popular pattern recognition approach, support vector machines, was used to predict the diagnosis. We observed relatively high accuracy of 79% (adults) and 78% (children) applying solely objective measures. Predicting an ADHD diagnosis using both subjective and objective measures exceeded the accuracy of objective measures for both adults (89.5%) and children (86.7%), with the subjective variables proving to be the most relevant. We argue that objective measures are more robust against rater bias and errors inherent in subjective measures and may be more replicable. Considering the high accuracy of objective measures only, we found in our study, we think that they should be incorporated in diagnostic procedures for assessing ADHD.

  4. Online phase measuring profilometry for rectilinear moving object by image correction

    NASA Astrophysics Data System (ADS)

    Yuan, Han; Cao, Yi-Ping; Chen, Chen; Wang, Ya-Pin

    2015-11-01

    In phase measuring profilometry (PMP), the object must be static for point-to-point reconstruction with the captured deformed patterns. While the object is rectilinearly moving online, the size and pixel position differences of the object in different captured deformed patterns do not meet the point-to-point requirement. We propose an online PMP based on image correction to measure the three-dimensional shape of the rectilinear moving object. In the proposed method, the deformed patterns captured by a charge-coupled diode camera are reprojected from the oblique view to an aerial view first and then translated based on the feature points of the object. This method makes the object appear stationary in the deformed patterns. Experimental results show the feasibility and efficiency of the proposed method.

  5. Characterization of Ocular Biomechanics in Pellucid Marginal Degeneration.

    PubMed

    Lenk, Janine; Haustein, Michael; Terai, Naim; Spoerl, Eberhard; Raiskup, Frederik

    2016-04-01

    This study sought to investigate the diagnostic capacity of corneal biomechanical response parameters in a group of patients with pellucid marginal degeneration (PMD) using the Ocular Response Analyzer (ORA) and Corvis ST devices. In this prospective clinical study, we used the Corvis ST and ORA devices to investigate the ocular biomechanics of patients with PMD. Eighty-one eyes were included, and 2 study groups were formed: the PMD group (the study group, n = 29) and the control group (n = 52). We focused on 13 biomechanical parameters. Statistical analysis was performed using SPSS. Biomechanical parameters for the 2 groups were compared using analysis of covariance. The ORA results demonstrated that the Keratoconus Match Index was significantly lower in the PMD group than in the control group (0.031 ± 0.37 vs. 0.79 ± 0.33; P = 0.001). The 2 groups did not significantly differ with respect to intraocular pressure- and central corneal thickness-adjusted values for corneal hysteresis or corneal resistance factor. Regarding the Corvis parameters, differences between the control and PMD groups were detected for CorWmax amp (control 1.01 ± 0.01, PMD 1.06 ± 0.01; P = 0.020) and CorA2 t (control 21.78 ± 0.03, PMD 21.66 ± 0.04; P = 0.0003). We identified 2 Corvis parameters that could be used to characterize PMD and differentiate PMD corneas from normal corneas. These parameters support the hypothesis that there is significantly less deformation of the central cornea in PMD corneas than in healthy corneas. However, because useful "first-line" diagnostic devices for diagnosing PMD (such as Pentacam and the ORA) exist, the Corvis ST serves as an additional diagnostic tool that can also be used for long-term monitoring after diagnosis confirmation.

  6. Biomechanics and running economy.

    PubMed

    Anderson, T

    1996-08-01

    Running economy, which has traditionally been measured as the oxygen cost of running at a given velocity, has been accepted as the physiological criterion for 'efficient' performance and has been identified as a critical element of overall distance running performance. There is an intuitive link between running mechanics and energy cost of running, but research to date has not established a clear mechanical profile of an economic runner. It appears that through training, individuals are able to integrate and accommodate their own unique combination of dimensions and mechanical characteristics so that they arrive at a running motion which is most economical for them. Information in the literature suggests that biomechanical factors are likely to contribute to better economy in any runner. A variety of anthropometric dimensions could influence biomechanical effectiveness. These include: average or slightly smaller than average height for men and slightly greater than average height for women; high ponderal index and ectomorphic or ectomesomorphic physique; low percentage body fat; leg morphology which distributes mass closer to the hip joint; narrow pelvis and smaller than average feet. Gait patterns, kinematics and the kinetics of running may also be related to running economy. These factors include: stride length which is freely chosen over considerable running time; low vertical oscillation of body centre of mass; more acute knee angle during swing; less range of motion but greater angular velocity of plantar flexion during toe-off; arm motion of smaller amplitude; low peak ground reaction forces; faster rotation of shoulders in the transverse plane; greater angular excursion of the hips and shoulders about the polar axis in the transverse plane; and effective exploitation of stored elastic energy. Other factors which may improve running economy are: lightweight but well-cushioned shoes; more comprehensive training history; and the running surface of intermediate

  7. Measuring Positions of Objects using Two or More Cameras

    NASA Technical Reports Server (NTRS)

    Klinko, Steve; Lane, John; Nelson, Christopher

    2008-01-01

    An improved method of computing positions of objects from digitized images acquired by two or more cameras (see figure) has been developed for use in tracking debris shed by a spacecraft during and shortly after launch. The method is also readily adaptable to such applications as (1) tracking moving and possibly interacting objects in other settings in order to determine causes of accidents and (2) measuring positions of stationary objects, as in surveying. Images acquired by cameras fixed to the ground and/or cameras mounted on tracking telescopes can be used in this method. In this method, processing of image data starts with creation of detailed computer- aided design (CAD) models of the objects to be tracked. By rotating, translating, resizing, and overlaying the models with digitized camera images, parameters that characterize the position and orientation of the camera can be determined. The final position error depends on how well the centroids of the objects in the images are measured; how accurately the centroids are interpolated for synchronization of cameras; and how effectively matches are made to determine rotation, scaling, and translation parameters. The method involves use of the perspective camera model (also denoted the point camera model), which is one of several mathematical models developed over the years to represent the relationships between external coordinates of objects and the coordinates of the objects as they appear on the image plane in a camera. The method also involves extensive use of the affine camera model, in which the distance from the camera to an object (or to a small feature on an object) is assumed to be much greater than the size of the object (or feature), resulting in a truly two-dimensional image. The affine camera model does not require advance knowledge of the positions and orientations of the cameras. This is because ultimately, positions and orientations of the cameras and of all objects are computed in a coordinate

  8. Biomechanical, anthropometric, and psychological determinants of barbell back squat strength.

    PubMed

    Vigotsky, Andrew D; Bryanton, Megan A; Nuckols, Greg; Beardsley, Chris; Contreras, Bret; Evans, Jessica; Schoenfeld, Brad J

    2018-02-27

    Previous investigations of strength have only focused on biomechanical or psychological determinants, while ignoring the potential interplay and relative contributions of these variables. The purpose of this study was to investigate the relative contributions of biomechanical, anthropometric, and psychological variables to the prediction of maximum parallel barbell back squat strength. Twenty-one college-aged participants (male = 14; female = 7; age = 23 ± 3 years) reported to the laboratory for two visits. The first visit consisted of anthropometric, psychometric, and parallel barbell back squat one-repetition maximum (1RM) testing. On the second visit, participants performed isometric dynamometry testing for the knee, hip, and spinal extensors in a sticking point position-specific manner. Multiple linear regression and correlations were used to investigate the combined and individual relationships between biomechanical, anthropometric, and psychological variables and squat 1RM. Multiple regression revealed only one statistically predictive determinant: fat free mass normalized to height (standardized estimate ± SE = 0.6 ± 0.3; t(16) = 2.28; p = 0.037). Correlation coefficients for individual variables and squat 1RM ranged from r = -0.79-0.83, with biomechanical, anthropometric, experiential, and sex predictors showing the strongest relationships, and psychological variables displaying the weakest relationships. These data suggest that back squat strength in a heterogeneous population is multifactorial and more related to physical rather than psychological variables.

  9. Different Measures of Structural Similarity Tap Different Aspects of Visual Object Processing

    PubMed Central

    Gerlach, Christian

    2017-01-01

    The structural similarity of objects has been an important variable in explaining why some objects are easier to categorize at a superordinate level than to individuate, and also why some patients with brain injury have more difficulties in recognizing natural (structurally similar) objects than artifacts (structurally distinct objects). In spite of its merits as an explanatory variable, structural similarity is not a unitary construct, and it has been operationalized in different ways. Furthermore, even though measures of structural similarity have been successful in explaining task and category-effects, this has been based more on implication than on direct empirical demonstrations. Here, the direct influence of two different measures of structural similarity, contour overlap and within-item structural diversity, on object individuation (object decision) and superordinate categorization performance is examined. Both measures can account for performance differences across objects, but in different conditions. It is argued that this reflects differences between the measures in whether they tap: (i) global or local shape characteristics, and (ii) between- or within-category structural similarity. PMID:28861027

  10. Development of a biomechanical energy harvester

    PubMed Central

    Li, Qingguo; Naing, Veronica; Donelan, J Maxwell

    2009-01-01

    Background Biomechanical energy harvesting–generating electricity from people during daily activities–is a promising alternative to batteries for powering increasingly sophisticated portable devices. We recently developed a wearable knee-mounted energy harvesting device that generated electricity during human walking. In this methods-focused paper, we explain the physiological principles that guided our design process and present a detailed description of our device design with an emphasis on new analyses. Methods Effectively harvesting energy from walking requires a small lightweight device that efficiently converts intermittent, bi-directional, low speed and high torque mechanical power to electricity, and selectively engages power generation to assist muscles in performing negative mechanical work. To achieve this, our device used a one-way clutch to transmit only knee extension motions, a spur gear transmission to amplify the angular speed, a brushless DC rotary magnetic generator to convert the mechanical power into electrical power, a control system to determine when to open and close the power generation circuit based on measurements of knee angle, and a customized orthopaedic knee brace to distribute the device reaction torque over a large leg surface area. Results The device selectively engaged power generation towards the end of swing extension, assisting knee flexor muscles by producing substantial flexion torque (6.4 Nm), and efficiently converted the input mechanical power into electricity (54.6%). Consequently, six subjects walking at 1.5 m/s generated 4.8 ± 0.8 W of electrical power with only a 5.0 ± 21 W increase in metabolic cost. Conclusion Biomechanical energy harvesting is capable of generating substantial amounts of electrical power from walking with little additional user effort making future versions of this technology particularly promising for charging portable medical devices. PMID:19549313

  11. New Directions in Assessment: Biomechanical Development.

    ERIC Educational Resources Information Center

    Fortney, Virginia

    Biomechanical analysis of human movement seeks to relate observable motions or configurations of the body to the forces that act to produce those motions or maintain those configurations. These are identified as force-motion relationships. In assessing force-motion relationships in children's movement, the process type assessment, Ohio State…

  12. How do prosthetic stiffness, height and running speed affect the biomechanics of athletes with bilateral transtibial amputations?

    PubMed Central

    Taboga, Paolo; Grabowski, Alena M.

    2017-01-01

    Limited available information describes how running-specific prostheses and running speed affect the biomechanics of athletes with bilateral transtibial amputations. Accordingly, we quantified the effects of prosthetic stiffness, height and speed on the biomechanics of five athletes with bilateral transtibial amputations during treadmill running. Each athlete performed a set of running trials with 15 different prosthetic model, stiffness and height combinations. Each set of trials began with the athlete running on a force-measuring treadmill at 3 m s−1, subsequent trials incremented by 1 m s−1 until they achieved their fastest attainable speed. We collected ground reaction forces (GRFs) during each trial. Prosthetic stiffness, height and running speed each affected biomechanics. Specifically, with stiffer prostheses, athletes exhibited greater peak and stance average vertical GRFs (β = 0.03; p < 0.001), increased overall leg stiffness (β = 0.21; p < 0.001), decreased ground contact time (β = −0.07; p < 0.001) and increased step frequency (β = 0.042; p < 0.001). Prosthetic height inversely associated with step frequency (β = −0.021; p < 0.001). Running speed inversely associated with leg stiffness (β = −0.58; p < 0.001). Moreover, at faster running speeds, the effect of prosthetic stiffness and height on biomechanics was mitigated and unchanged, respectively. Thus, prosthetic stiffness, but not height, likely influences distance running performance more than sprinting performance for athletes with bilateral transtibial amputations. PMID:28659414

  13. How do prosthetic stiffness, height and running speed affect the biomechanics of athletes with bilateral transtibial amputations?

    PubMed

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-06-01

    Limited available information describes how running-specific prostheses and running speed affect the biomechanics of athletes with bilateral transtibial amputations. Accordingly, we quantified the effects of prosthetic stiffness, height and speed on the biomechanics of five athletes with bilateral transtibial amputations during treadmill running. Each athlete performed a set of running trials with 15 different prosthetic model, stiffness and height combinations. Each set of trials began with the athlete running on a force-measuring treadmill at 3 m s -1 , subsequent trials incremented by 1 m s -1 until they achieved their fastest attainable speed. We collected ground reaction forces (GRFs) during each trial. Prosthetic stiffness, height and running speed each affected biomechanics. Specifically, with stiffer prostheses, athletes exhibited greater peak and stance average vertical GRFs ( β = 0.03; p < 0.001), increased overall leg stiffness ( β = 0.21; p < 0.001), decreased ground contact time ( β = -0.07; p < 0.001) and increased step frequency ( β = 0.042; p < 0.001). Prosthetic height inversely associated with step frequency ( β = -0.021; p < 0.001). Running speed inversely associated with leg stiffness ( β = -0.58; p < 0.001). Moreover, at faster running speeds, the effect of prosthetic stiffness and height on biomechanics was mitigated and unchanged, respectively. Thus, prosthetic stiffness, but not height, likely influences distance running performance more than sprinting performance for athletes with bilateral transtibial amputations. © 2017 The Author(s).

  14. The physiological and biomechanical effects of forwards and reverse sports wheelchair propulsion.

    PubMed

    Mason, Barry S; Lenton, John P; Goosey-Tolfrey, Victoria L

    2015-07-01

    To explore the physiological and biomechanical differences between forwards (FOR) and reverse (REV) sports wheelchair propulsion. Fourteen able-bodied males with previous wheelchair propulsion experience pushed a sports wheelchair on a single-roller ergometer in a FOR and REV direction at three sub-maximal speeds (4, 6, and 8 km/hour). Each trial lasted 3 minutes, and during the final minute physiological and biomechanical measures was collected. The physiological results revealed that oxygen uptake (1.51 ± 0.29 vs. 1.38 ± 0.26 L/minute, P = 0.005) and heart rate (121 ± 19 vs. 109 ± 14 beats/minute, P < 0.0005) were significantly greater during REV than FOR only during the 8 km/hour trials. From a biomechanical perspective, push frequencies were similar between FOR and REV across all speeds (P > 0.05). However, greater mean resultant forces were applied during FOR (P < 0.0005) at 4 km/hour (66.7 ± 19.5 vs. 49.2 ± 10.3 N), 6 km/hour (90.7 ± 21.9 vs. 65.3 ± 18.6 N), and 8 km/hour (102.5 ± 17.6 vs. 68.7 ± 13.5 N) compared to REV. Alternatively, push times and push angles were significantly lower (P ≤ 0.001) during FOR at each speed. The current study demonstrated that at higher speeds physiological demand becomes elevated during REV. This was likely to be associated with an inability to apply sufficient force to the wheels, thus requiring kinematic adaptations in order to maintain constant speeds in REV.

  15. Optical spectroscopic characterization of human meniscus biomechanical properties

    NASA Astrophysics Data System (ADS)

    Ala-Myllymäki, Juho; Danso, Elvis K.; Honkanen, Juuso T. J.; Korhonen, Rami K.; Töyräs, Juha; Afara, Isaac O.

    2017-12-01

    This study investigates the capacity of optical spectroscopy in the visible (VIS) and near-infrared (NIR) spectral ranges for estimating the biomechanical properties of human meniscus. Seventy-two samples obtained from the anterior, central, and posterior locations of the medial and lateral menisci of 12 human cadaver joints were used. The samples were subjected to mechanical indentation, then traditional biomechanical parameters (equilibrium and dynamic moduli) were calculated. In addition, strain-dependent fibril network modulus and permeability strain-dependency coefficient were determined via finite-element modeling. Subsequently, absorption spectra were acquired from each location in the VIS (400 to 750 nm) and NIR (750 to 1100 nm) spectral ranges. Partial least squares regression, combined with spectral preprocessing and transformation, was then used to investigate the relationship between the biomechanical properties and spectral response. The NIR spectral region was observed to be optimal for model development (83.0%≤R2≤90.8%). The percentage error of the models are: Eeq (7.1%), Edyn (9.6%), Eɛ (8.4%), and Mk (8.9%). Thus, we conclude that optical spectroscopy in the NIR range is a potential method for rapid and nondestructive evaluation of human meniscus functional integrity and health in real time during arthroscopic surgery.

  16. Calcium requirements of growing rats based on bone mass, structure, or biomechanical strength are similar.

    PubMed

    Hunt, Janet R; Hunt, Curtiss D; Zito, Carol Ann; Idso, Joseph P; Johnson, LuAnn K

    2008-08-01

    Although calcium (Ca) supplementation increases bone density, the increase is small and the effect on bone strength and fracture risk is uncertain. To investigate if bone mass, morphology, and biomechanical properties are affected by deficient to copious dietary Ca concentrations, the long bones (tibia and femur) of growing female Sprague-Dawley rats (8/group) were assessed after 13 wk of consuming 1, 2, 3, 4, 5, 6, or 7 g Ca/kg of a modified AIN-93G diet. Dietary phosphorous (P) and vitamin D remained constant at recommended concentrations. The assessment included mineralization, density, biomechanical properties of breaking by a 3-point flexure test, and morphological properties by microcomputed topography scanning of trabecular bone of the proximal tibia metaphysis. Dietary treatment did not affect food intake, weight gain, renal and muscle Ca concentrations, and bone hydroxyproline. All bone parameters measured were significantly impaired by Ca deficiency in rats fed the diet containing 1 g Ca/kg. Modest impairments occurred with some parameters (bone density, biomechanical bending moment, modulus of elasticity, and stress) in rats fed 2 g Ca/kg, but all parameters stabilized between 2 and 3 g/kg diet, with no differences between 3 and 7 g/kg. The results suggest that a threshold response in bone Ca retention or bone mass at approximately 2.5 g Ca/kg diet is associated with similar threshold responses in bone breaking strength and related biomechanics as well as trabecular structural properties. There was no evidence of a relative P deficiency or of improved or impaired bone strength and structure as Ca intakes increased beyond those needed to maximize bone density.

  17. Changes in Lower Extremity Biomechanics Due to a Short-Term Fatigue Protocol

    PubMed Central

    Cortes, Nelson; Greska, Eric; Kollock, Roger; Ambegaonkar, Jatin; Onate, James A.

    2013-01-01

    Context: Noncontact anterior cruciate ligament injury has been reported to occur during the later stages of a game when fatigue is most likely present. Few researchers have focused on progressive changes in lower extremity biomechanics that occur throughout fatiguing. Objective: To evaluate the effects of a sequential fatigue protocol on lower extremity biomechanics during a sidestep-cutting task (SS). Design: Controlled laboratory study. Setting: Laboratory. Patients or Other Participants: Eighteen uninjured female collegiate soccer players (age = 19.2 ± 0.9 years, height = 1.66 ± 0.5 m, mass = 61.6 ± 5.1 kg) volunteered. Intervention(s): The independent variable was fatigue level, with 3 levels (prefatigue, 50% fatigue, and 100% fatigue). Using 3-dimensional motion capture, we assessed lower extremity biomechanics during the SS. Participants alternated between a fatigue protocol that solicited different muscle groups and mimicked actual sport situations and unanticipated SS trials. The process was repeated until fatigue was attained. Main Outcome Measure(s): Dependent variables were hip- and knee-flexion and abduction angles and internal moments measured at initial contact and peak stance and defined as measures obtained between 0% and 50% of stance phase. Results: Knee-flexion angle decreased from prefatigue (−17° ± 5°) to 50% fatigue (−16° ± 6°) and to 100% fatigue (−14° ± 4°) (F2,34 = 5.112, P = .004). Knee flexion at peak stance increased from prefatigue (−52.9° ± 5.6°) to 50% fatigue (−56.1° ± 7.2°) but decreased from 50% to 100% fatigue (−50.5° ± 7.1°) (F2,34 = 8.282, P = 001). Knee-adduction moment at peak stance increased from prefatigue (0.49 ± 0.23 Nm/kgm) to 50% fatigue (0.55 ± 0.25 Nm/kgm) but decreased from 50% to 100% fatigue (0.37 ± 0.24) (F2,34 = 3.755, P = 03). Hip-flexion angle increased from prefatigue (45.4° ± 10.9°) to 50% fatigue (46.2° ± 11.2°) but decreased from 50% to 100% fatigue (40.9° ± 11.3

  18. Biomechanical Modeling Analysis of Loads Configuration for Squat Exercise

    NASA Technical Reports Server (NTRS)

    Gallo, Christopher A.; Thompson, William K.; Lewandowski, Beth E.; Jagodnik, Kathleen; De Witt, John K.

    2017-01-01

    INTRODUCTION: Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft for travel to the Moon or to Mars is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. METHODS The computational models currently under development utilize the OpenSim [1] software platform, consisting of open source code for musculoskeletal modeling, using biomechanical input data from test subjects for estimation of muscle and joint loads. The OpenSim Full Body Model [2] is used for all analyses. The model incorporates simplified wrap surfaces, a new knee model and updated lower body muscle parameters derived from cadaver measurements and magnetic resonance imaging of young adults. The upper body uses torque actuators at the lumbar and extremity joints. The test subjects who volunteer for this study are instrumented with reflective markers for motion capture data collection while performing squat exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device (ZIN Technologies, Middleburg Heights, OH). Ground reaction force data is collected with force plates under the feet, and device loading is recorded through load cells internal to the HULK. Test variables include

  19. Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures

    PubMed Central

    Meffert, Rainer H.; Raschke, Michael J.; Blunk, Torsten; Ochman, Sabine

    2014-01-01

    Purpose. To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. Methods. Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical screw fixation followed. Under cyclic loading, the displacement, and in subsequent load-to-failure tests, the maximum load and stiffness were measured. Results. For the monocortical screw fixation of the locking plate, a similar displacement, maximum load, and stiffness could be demonstrated compared to the bicortical screw fixation of the nonlocking plate. Conclusions. Locking plates in monocortical configuration may function as a useful alternative to the currently common treatment with bicortical fixations. Thereby, irritation of the flexor tendons would be avoided without compromising the stability, thus enabling the necessary early functional rehabilitation. PMID:24757429

  20. A novel mouse running wheel that senses individual limb forces: biomechanical validation and in vivo testing

    PubMed Central

    Roach, Grahm C.; Edke, Mangesh

    2012-01-01

    Biomechanical data provide fundamental information about changes in musculoskeletal function during development, adaptation, and disease. To facilitate the study of mouse locomotor biomechanics, we modified a standard mouse running wheel to include a force-sensitive rung capable of measuring the normal and tangential forces applied by individual paws. Force data were collected throughout the night using an automated threshold trigger algorithm that synchronized force data with wheel-angle data and a high-speed infrared video file. During the first night of wheel running, mice reached consistent running speeds within the first 40 force events, indicating a rapid habituation to wheel running, given that mice generated >2,000 force-event files/night. Average running speeds and peak normal and tangential forces were consistent throughout the first four nights of running, indicating that one night of running is sufficient to characterize the locomotor biomechanics of healthy mice. Twelve weeks of wheel running significantly increased spontaneous wheel-running speeds (16 vs. 37 m/min), lowered duty factors (ratio of foot-ground contact time to stride time; 0.71 vs. 0.58), and raised hindlimb peak normal forces (93 vs. 115% body wt) compared with inexperienced mice. Peak normal hindlimb-force magnitudes were the primary force component, which were nearly tenfold greater than peak tangential forces. Peak normal hindlimb forces exceed the vertical forces generated during overground running (50-60% body wt), suggesting that wheel running shifts weight support toward the hindlimbs. This force-instrumented running-wheel system provides a comprehensive, noninvasive screening method for monitoring gait biomechanics in mice during spontaneous locomotion. PMID:22723628

  1. A biomechanical model for actively controlled snow ski bindings.

    PubMed

    Hull, M L; Ramming, J E

    1980-11-01

    Active control of snow ski bindings is a new design concept which potentially offers improved protection from lower extremity injury. Implementation of this concept entails measuring physical variables and calculating loading and/or deformation in injury prone musculoskeletal components. The subject of this paper is definition of a biomechanical model for calculating tibia torsion based on measurements of torsion loading between the boot and ski. Previous control schemes have used leg displacement only to indicate tibia torsion. The contributions of both inertial and velocity-dependent torques to tibia loading are explored and it is shown that both these moments must be included in addition to displacement-dependent moments. A new analog controller design which includes inertia, damping, and stiffness terms in the tibia load calculation is also presented.

  2. Objective Measures of Visual Function in Papilledema

    PubMed Central

    Moss, Heather E.

    2016-01-01

    Synopsis Visual function is an important parameter to consider when managing patients with papilledema. Though the current standard of care uses standard automated perimetry (SAP) to obtain this information, this test is inherently subjective and prone to patient errors. Objective visual function tests including the visual evoked potential, pattern electroretinogram, photopic negative response of the full field electroretinogram, and pupillary light response have the potential to replace or supplement subjective visual function tests in papilledema management. This article reviews the evidence for use of objective visual function tests to assess visual function in papilledema and discusses future investigations needed to develop them as clinically practical and useful measures for this purpose. PMID:28451649

  3. Biomechanical Characteristics and Determinants of Instep Soccer Kick

    PubMed Central

    Kellis, Eleftherios; Katis, Athanasios

    2007-01-01

    Good kicking technique is an important aspect of a soccer player. Therefore, understanding the biomechanics of soccer kicking is particularly important for guiding and monitoring the training process. The purpose of this review was to examine latest research findings on biomechanics of soccer kick performance and identify weaknesses of present research which deserve further attention in the future. Being a multiarticular movement, soccer kick is characterised by a proximal-to-distal motion of the lower limb segments of the kicking leg. Angular velocity is maximized first by the thigh, then by the shank and finally by the foot. This is accomplished by segmental and joint movements in multiple planes. During backswing, the thigh decelerates mainly due to a motion-dependent moment from the shank and, to a lesser extent, by activation of hip muscles. In turn, forward acceleration of the shank is accomplished through knee extensor moment as well as a motion-dependent moment from the thigh. The final speed, path and spin of the ball largely depend on the quality of foot-ball contact. Powerful kicks are achieved through a high foot velocity and coefficient of restitution. Preliminary data indicate that accurate kicks are achieved through slower kicking motion and ball speed values. Key pointsSoccer kick is achieved through segmental and joint rotations in multiple planes and via the proximal-to-distal sequence of segmental angular velocities until ball impact. The quality of ball - foot impact and the mechanical behavior of the foot are also important determinants of the final speed, path and spin of the ball.Ball speed values during the maximum instep kick range from 18 to 35 msec-1 depending on various factors, such as skill level, age, approach angle and limb dominance.The main bulk of biomechanics research examined the biomechanics of powerful kicks, mostly under laboratory conditions. A powerful kick is characterized by the achievement of maximal ball speed. However

  4. Biomechanical and ergonomic assessment of urban transit operators.

    PubMed

    Albert, Wayne J; Everson, Donald; Rae, Michelle; Callaghan, Jack P; Croll, Jim; Kuruganti, Usha

    2014-01-01

    The prevalence of neck and low back musculoskeletal injuries in transit operators has been shown to be high; with work absences exceeding double the National average. There is a lack of biomechanical data generated from field researches to inform on musculoskeletal risk associated with transportation and driving occupations. Instead there has been a reliance on simulated driving and questionnaire-based research. This study was designed to examine the musculoskeletal and biomechanical stresses experienced by urban bus drivers. The main objective was to obtain a baseline understanding of sitting posture, muscle activiation and subjective ratings of stress during regular driving tasks. Fifteen urban city bus drivers were recruited for this study. Bus drivers drove the same 65-minute bus route once, at the same time of day, in the same preselected bus. Wireless surface electromyography monitored muscular activity of the drivers' neck, upper trapezius, and erector spinae and video analysis and seat pressure mapping was used to monitor changes in driving posture. A health and lifestyle questionnaire was administered to record specific neck and back pain experienced by drivers as well as to provide lifestyle habits. Drivers were found to exhibit non-neutral postures for less than 30% of the time while conducting routine tasks of turning and stopping for passenger loading and unloading. The neck posture was the greatest concern in terms of non-neutral posture and this was supported by the higher muscle activation to the neck musculature. There was significant posture adjustment made during the one-hour driving period with the adjustments increasing with driving time. Activities associated with bus driving appear to require the use of non-neutral postures an increase in muscle activation. Significant postural adjustments were needed over the one-hour observation period suggesting that the musculoskeletal demands may increase over a regular 12-hour shift.

  5. Training for Women's Basketball: A Biomechanical Emphasis for Preventing Anterior Cruciate Ligament Injury.

    ERIC Educational Resources Information Center

    Pettitt, Robert W.; Bryson, Erin R.

    2002-01-01

    Summarizes proposed variables linked with higher incidences of anterior cruciate ligament tears in females and the biomechanical aspects of the lower extremity during the performance of common basketball skills, focusing on gender differences in knee joint stability and neuromuscular control, biomechanical aspects of lower extremity skills in…

  6. Biomechanical pulping : a mill-scale evaluation

    Treesearch

    Masood Akhtar; Gary M. Scott; Ross E. Swaney; Mike J. Lentz; Eric G. Horn; Marguerite S. Sykes; Gary C. Myers

    1999-01-01

    Mechanical pulping process is electrical energy intensive and results in low paper strength. Biomechanical pulping, defined as the fungal treatment of lignocellulosic materials prior to mechanical pulping, has shown at least 30% savings in electrical energy consumption, and significant improvements in paper strength properties compared to the control at a laboratory...

  7. Scapholunate Interosseous Ligament Anatomy and Biomechanics.

    PubMed

    Rajan, Prashant V; Day, Charles S

    2015-08-01

    Injury to the scapholunate interosseous ligament is one of the most common causes of carpal instability and can impart considerable compromise to the patient's hand function. However, the management of scapholunate ligament injuries remains a dynamic concept, especially with regard to the multitude of options and techniques that exist for its surgical treatment. We present a thorough review of scapholunate anatomy and morphology, and the role of the scapholunate articulations in the kinetics and pathomechanics of wrist instability. We also review the current literature on the biomechanical properties of the scapholunate ligament and its subcomponents. A sound understanding of the anatomy and biomechanics of the scapholunate ligament can clarify its instability and may better orient current reconstructive procedures or pioneer better future techniques. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. Physiological and Biomechanical Considerations for a Human Mars Mission

    NASA Astrophysics Data System (ADS)

    Hawkey, A.

    Evolving on Earth has made humans perfectly adapted, both physiologically and biomechanically, to its gravity and atmospheric conditions. Leaving the Earth and its protective environment, therefore, results in the degradation of a number of human systems. Long-duration stays on the International Space Station (ISS) are accompanied by significant effects on crew's cardiovascular, vestibular and musculoskeletal systems. Bone loss and muscle atrophy are experienced at a rate of 1-3% and 5% per month respectively, while VO2 (oxygen consumption) measurements are reduced by approximately 25% after a few weeks in space. If these figures are simply extrapolated, a future human mission to Mars will be seriously jeopardised and crews may find they cross the threshold of bone and muscle loss and aerobic fitness - ultimately with them being unable to return to Earth. When arriving on Mars, considerable biomechanical alterations will also occur. Optimum walking speeds will be approximately 30% lower and transitioning from a walk to a run will occur at a speed 25% slower. Peak vertical forces will be reduced by as much as 50%, while stride length, stride time and airborne time will all increase. On Mars, half as much energy will be required to travel the equivalent distance on Earth and it will be 65% more economical to run rather than to walk.

  9. Background oriented schlieren measurement of the refractive index field of air induced by a hot, cylindrical measurement object.

    PubMed

    Beermann, Rüdiger; Quentin, Lorenz; Pösch, Andreas; Reithmeier, Eduard; Kästner, Markus

    2017-05-10

    To optically capture the topography of a hot measurement object with high precision, the light deflection by the inhomogeneous refractive index field-induced by the heat transfer from the measurement object to the ambient medium-has to be considered. We used the 2D background oriented schlieren method with illuminated wavelet background, an optical flow algorithm, and Ciddor's equation to quantify the refractive index field located directly above a red-glowing, hot measurement object. A heat transfer simulation has been implemented to verify the magnitude and the shape of the measured refractive index field. Provided that no forced external flow is disturbing the shape of the convective flow originating from the hot object, a laminar flow can be observed directly above the object, resulting in a sharply bounded, inhomogeneous refractive index field.

  10. Maximum human objectively measured pharmacologically stimulated accommodative amplitude.

    PubMed

    Grzybowski, Andrzej; Schachar, Ronald A; Gaca-Wysocka, Magdalena; Schachar, Ira H; Pierscionek, Barbara K

    2018-01-01

    To measure the maximum, objectively measured, accommodative amplitude, produced by pharmacologic stimulation. Thirty-seven healthy subjects were enrolled, with a mean age of 20.2±1.1 years, corrected visual acuity of 20/20, and mean spherical equivalent refraction (SER) =-0.83±1.60 diopters. For each subject, the right pupil was dilated with phenylephrine 10%. After 30 minutes, the pupil was measured, the left eye was patched, and the right eye was autorefracted. Pilocarpine 4% was then instilled in the right eye, followed by phenylephrine. At 45 minutes after the pilocarpine, autorefraction and pupil size were again measured. Mean pupil size pre- and postpilocarpine was 8.0±0.8 mm and 4.4±1.9 mm, respectively. Pre- and postpilocarpine, the mean SER was -0.83±1.60 and -10.55±4.26 diopters, respectively. The mean pilocarpine-induced accommodative amplitude was 9.73±3.64 diopters. Five subjects had accommodative amplitudes ≥14.00 diopters. Accommodative amplitude was not significantly related to baseline SER ( p -value =0.24), pre- or postpilocarpine pupil size ( p -values =0.13 and 0.74), or change in pupil size ( p -value =0.37). Iris color did not statistically significantly affect accommodative amplitude ( p -value =0.83). Following topically applied pilocarpine, the induced objectively measured accommodation in the young eye is greater than or equal to the reported subjectively measured voluntary maximum accommodative amplitude.

  11. Detecting dynamical boundaries from kinematic data in biomechanics

    NASA Astrophysics Data System (ADS)

    Ross, Shane D.; Tanaka, Martin L.; Senatore, Carmine

    2010-03-01

    Ridges in the state space distribution of finite-time Lyapunov exponents can be used to locate dynamical boundaries. We describe a method for obtaining dynamical boundaries using only trajectories reconstructed from time series, expanding on the current approach which requires a vector field in the phase space. We analyze problems in musculoskeletal biomechanics, considered as exemplars of a class of experimental systems that contain separatrix features. Particular focus is given to postural control and balance, considering both models and experimental data. Our success in determining the boundary between recovery and failure in human balance activities suggests this approach will provide new robust stability measures, as well as measures of fall risk, that currently are not available and may have benefits for the analysis and prevention of low back pain and falls leading to injury, both of which affect a significant portion of the population.

  12. Wheelchair Propulsion Biomechanics in Junior Basketball Players: A Method for the Evaluation of the Efficacy of a Specific Training Program

    PubMed Central

    Bergamini, Elena; Morelli, Francesca; Marchetti, Flavia; Vannozzi, Giuseppe; Polidori, Lorenzo; Paradisi, Francesco; Traballesi, Marco; Cappozzo, Aurelio

    2015-01-01

    As participation in wheelchair sports increases, the need of quantitative assessment of biomechanical performance indicators and of sports- and population-specific training protocols has become central. The present study focuses on junior wheelchair basketball and aims at (i) proposing a method to identify biomechanical performance indicators of wheelchair propulsion using an instrumented in-field test and (ii) developing a training program specific for the considered population and assessing its efficacy using the proposed method. Twelve athletes (10 M, 2 F, age = 17.1 ± 2.7 years, years of practice = 4.5 ± 1.8) equipped with wheelchair- and wrist-mounted inertial sensors performed a 20-metre sprint test. Biomechanical parameters related to propulsion timing, progression force, and coordination were estimated from the measured accelerations and used in a regression model where the time to complete the test was set as dependent variable. Force- and coordination-related parameters accounted for 80% of the dependent variable variance. Based on these results, a training program was designed and administered for three months to six of the athletes (the others acting as control group). The biomechanical indicators proved to be effective in providing additional information about the wheelchair propulsion technique with respect to the final test outcome and demonstrated the efficacy of the developed program. PMID:26543852

  13. Are Cranial Biomechanical Simulation Data Linked to Known Diets in Extant Taxa? A Method for Applying Diet-Biomechanics Linkage Models to Infer Feeding Capability of Extinct Species

    PubMed Central

    Tseng, Zhijie Jack; Flynn, John J.

    2015-01-01

    Performance of the masticatory system directly influences feeding and survival, so adaptive hypotheses often are proposed to explain craniodental evolution via functional morphology changes. However, the prevalence of “many-to-one” association of cranial forms and functions in vertebrates suggests a complex interplay of ecological and evolutionary histories, resulting in redundant morphology-diet linkages. Here we examine the link between cranial biomechanical properties for taxa with different dietary preferences in crown clade Carnivora, the most diverse clade of carnivorous mammals. We test whether hypercarnivores and generalists can be distinguished based on cranial mechanical simulation models, and how such diet-biomechanics linkages relate to morphology. Comparative finite element and geometric morphometrics analyses document that predicted bite force is positively allometric relative to skull strain energy; this is achieved in part by increased stiffness in larger skull models and shape changes that resist deformation and displacement. Size-standardized strain energy levels do not reflect feeding preferences; instead, caniform models have higher strain energy than feliform models. This caniform-feliform split is reinforced by a sensitivity analysis using published models for six additional taxa. Nevertheless, combined bite force-strain energy curves distinguish hypercarnivorous versus generalist feeders. These findings indicate that the link between cranial biomechanical properties and carnivoran feeding preference can be clearly defined and characterized, despite phylogenetic and allometric effects. Application of this diet-biomechanics linkage model to an analysis of an extinct stem carnivoramorphan and an outgroup creodont species provides biomechanical evidence for the evolution of taxa into distinct hypercarnivorous and generalist feeding styles prior to the appearance of crown carnivoran clades with similar feeding preferences. PMID:25923776

  14. Change-of-Direction Biomechanics: Is What's Best for Anterior Cruciate Ligament Injury Prevention Also Best for Performance?

    PubMed

    Fox, Aaron S

    2018-05-02

    Change-of-direction maneuvers (e.g., side-step cutting) are an important aspect of performance in multi-directional sports, but these maneuvers are also associated with anterior cruciate ligament (ACL) injury. Despite this, the impact of biomechanics on ACL injury risk and performance is often examined in isolation. The purpose of this review was to examine the alignment between biomechanical recommendations for ACL injury prevention and performance with regard to change-of-direction maneuvers. Several studies linking change-of-direction biomechanics to both ACL injury risk and performance were examined. A degree of overlap was identified between biomechanical strategies that could both reduce ACL injury risk and enhance performance during change-of-direction maneuvers. A fore-foot footfall pattern along with trunk rotation and lateral flexion in the intended cutting direction were identified as biomechanical strategies that could both reduce potentially hazardous knee joint moments and enhance change-of-direction speed. Minimizing knee valgus during change-of-direction maneuvers may also reduce ACL injury risk, with this biomechanical strategy found to have no impact on performance. Certain biomechanical strategies proposed to reduce ACL injury risk were linked to reduced change-of-direction performance. A narrow foot placement and "soft" landings with greater knee flexion were identified as ACL injury prevention strategies that could have a negative impact on performance. The findings of this review emphasize the need to consider both ACL injury risk and performance when examining the biomechanics of change-of-direction maneuvers.

  15. Fusion of intraoperative force sensoring, surface reconstruction and biomechanical modeling

    NASA Astrophysics Data System (ADS)

    Röhl, S.; Bodenstedt, S.; Küderle, C.; Suwelack, S.; Kenngott, H.; Müller-Stich, B. P.; Dillmann, R.; Speidel, S.

    2012-02-01

    Minimally invasive surgery is medically complex and can heavily benefit from computer assistance. One way to help the surgeon is to integrate preoperative planning data into the surgical workflow. This information can be represented as a customized preoperative model of the surgical site. To use it intraoperatively, it has to be updated during the intervention due to the constantly changing environment. Hence, intraoperative sensor data has to be acquired and registered with the preoperative model. Haptic information which could complement the visual sensor data is still not established. In addition, biomechanical modeling of the surgical site can help in reflecting the changes which cannot be captured by intraoperative sensors. We present a setting where a force sensor is integrated into a laparoscopic instrument. In a test scenario using a silicone liver phantom, we register the measured forces with a reconstructed surface model from stereo endoscopic images and a finite element model. The endoscope, the instrument and the liver phantom are tracked with a Polaris optical tracking system. By fusing this information, we can transfer the deformation onto the finite element model. The purpose of this setting is to demonstrate the principles needed and the methods developed for intraoperative sensor data fusion. One emphasis lies on the calibration of the force sensor with the instrument and first experiments with soft tissue. We also present our solution and first results concerning the integration of the force sensor as well as accuracy to the fusion of force measurements, surface reconstruction and biomechanical modeling.

  16. Research on measurement method of optical camouflage effect of moving object

    NASA Astrophysics Data System (ADS)

    Wang, Juntang; Xu, Weidong; Qu, Yang; Cui, Guangzhen

    2016-10-01

    Camouflage effectiveness measurement as an important part of the camouflage technology, which testing and measuring the camouflage effect of the target and the performance of the camouflage equipment according to the tactical and technical requirements. The camouflage effectiveness measurement of current optical band is mainly aimed at the static target which could not objectively reflect the dynamic camouflage effect of the moving target. This paper synthetical used technology of dynamic object detection and camouflage effect detection, the digital camouflage of the moving object as the research object, the adaptive background update algorithm of Surendra was improved, a method of optical camouflage effect detection using Lab-color space in the detection of moving-object was presented. The binary image of moving object is extracted by this measurement technology, in the sequence diagram, the characteristic parameters such as the degree of dispersion, eccentricity, complexity and moment invariants are constructed to construct the feature vector space. The Euclidean distance of moving target which through digital camouflage was calculated, the results show that the average Euclidean distance of 375 frames was 189.45, which indicated that the degree of dispersion, eccentricity, complexity and moment invariants of the digital camouflage graphics has a great difference with the moving target which not spray digital camouflage. The measurement results showed that the camouflage effect was good. Meanwhile with the performance evaluation module, the correlation coefficient of the dynamic target image range 0.1275 from 0.0035, and presented some ups and down. Under the dynamic condition, the adaptability of target and background was reflected. In view of the existing infrared camouflage technology, the next step, we want to carry out the camouflage effect measurement technology of the moving target based on infrared band.

  17. Hip Biomechanics Are Altered in Male Runners with Achilles Tendinopathy.

    PubMed

    Creaby, Mark W; Honeywill, Conor; Franettovich Smith, Melinda M; Schache, Anthony G; Crossley, Kay M

    2017-03-01

    Achilles tendinopathy (AT) is a prevalent injury in running sports. Understanding the biomechanical factors associated with AT will assist in its management and prevention. The purpose of this study was to compare hip and ankle kinematics and kinetics in runners with and without AT. Fourteen male runners with AT and 11 healthy male runners (CTRL) ran over ground while lower-limb joint motion and ground reaction force data were synchronously captured. Hip and ankle joint angles, moments, and impulses in all three planes (sagittal, transverse, and frontal) were extracted for analysis. Independent t-tests were used to compare the differences between the AT and the CTRL groups for the biomechanical variables of interest. After Bonferroni adjustment, an alpha level of 0.0026 was set for all analyses. The AT group exhibited an increased peak hip external rotation moment (P = 0.001), hip external rotation impulse (P < 0.001), and hip adduction impulse (P < 0.001) compared with the CTRL group. No significant differences in ankle biomechanics were observed. This study presents preliminary evidence indicating that male runners with AT display altered hip biomechanics with respect to their healthy counterparts. Because of the retrospective design of the study, it is unknown whether these alterations are a predisposing factor for the disorder, a result of the condition, or a combination of both. The results of this study suggest that optimizing hip joint function should be considered in the rehabilitation of runners with AT.

  18. Biomechanical Properties of a Novel Biodegradable Magnesium-Based Interference Screw

    PubMed Central

    Ezechieli, Marco; Meyer, Hanna; Lucas, Arne; Helmecke, Patrick; Becher, Christoph; Calliess, Tilman; Windhagen, Henning; Ettinger, Max

    2016-01-01

    Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a standard implant (Milagro®; De Puy Mitek, Raynham, MA, USA) were used for graft fixation. Specimens were placed into a tensile loading fixation of a servohydraulic testing machine. Biomechanical analysis included pretensioning of the constructs at 20 N for 1 min following cyclic pretensioning of 20 cycles between 20 and 60 N. Biomechanical elongation was evaluated with cyclic loading of 1000 cycles between 50 and 200 N at 0.5 Hz. Maximum load to failure was 511.3±66.5 N for the Milagro® screw and 529.0±63.3 N for magnesium-based screw (ns, P=0.57). Elongations after preload, during cyclical loading and during failure load were not different between the groups (ns, P>0.05). Stiffness was 121.1±13.8 N/mm for the magnesium-based screw and 144.1±18.4 for the Milagro® screw (ns, P=0.32). MgYREZr alloy interference screws show comparable results in biomechanical testing to standard implants and may be an alternative for anterior cruciate reconstruction in the future. PMID:27433303

  19. Novel methodology to obtain salient biomechanical characteristics of insole materials.

    PubMed

    Lavery, L A; Vela, S A; Ashry, H R; Lanctot, D R; Athanasiou, K A

    1997-06-01

    Viscoelastic inserts are commonly used as artificial shock absorbers to prevent neuropathic foot ulcerations by decreasing pressure on the sole of the foot. Unfortunately, there is little scientific information available to guide physicians in the selection of appropriate insole materials. Therefore, a novel methodology was developed to form a rational platform for biomechanical characterizations of insole material durability, which consisted of in vivo gait analysis and in vitro bioengineering measurements. Results show significant differences in the compressive stiffness of the tested insoles and the rate of change over time in both compressive stiffness and peak pressures measured. Good correlations were found between pressure-time integral and Young's modulus (r2 = 0.93), and total energy applied and Young's modulus (r2 = 0.87).

  20. An overview of Space Shuttle anthropometry and biomechanics research with emphasis on STS/Mir recumbent seat system design

    NASA Technical Reports Server (NTRS)

    Klute, Glenn K.; Stoycos, Lara E.

    1994-01-01

    The Anthropometry and Biomechanics Laboratory (ABL) at JSC conducts multi-disciplinary research focusing on maximizing astronaut intravehicular (IVA) and extravehicular (EVA) capabilities to provide the most effective work conditions for manned space flight and exploration missions. Biomechanics involves the measurement and modeling of the strength characteristics of the human body. Current research for the Space Shuttle Program includes the measurement of torque wrench capability during weightlessness, optimization of foot restraint, and hand hold placement, measurements of the strength and dexterity of the pressure gloved hand to improve glove design, quantification of the ability to move and manipulate heavy masses (6672 N or 1500 lb) in weightlessness, and verification of the capability of EVA crewmembers to perform Hubble Space Telescope repair tasks. Anthropometry is the measurement and modeling of the dimensions of the human body. Current research for the Space Shuttle Program includes the measurement of 14 anthropometric parameters of every astronaut candidate, identification of EVA finger entrapment hazards by measuring the dimensions of the gloved hand, definition of flight deck reach envelopes during launch and landing accelerations, and measurement of anthropometric design parameters for the recumbent seat system required for the Shuttle/Mir mission (STS-71, Spacelab M) scheduled for Jun. 1995.

  1. Walking on water: the biomechanics of Michael A. MacConaill (1902-1987).

    PubMed

    Prendergast, P J; Lee, T C

    2006-01-01

    Biomechanics is a subject that draws on knowledge from many disciplines. One of its great practitioners in the last century was the Irish anatomist M.A. MacConaill. In this paper, we review some of MacConaill's fundamental contributions to biomechanics, namely: the hydrodynamic theory of synovial joint lubrication, the kinematics of joint motion and conjunct rotations; and the theory of spurt and shunt muscles. The aim is to revisit these topics in the light of current research, and to draw some conclusions about the import of his research in the context of recent developments in the field. The paper concludes with a discussion of science in Ireland, the development of the field of biomechanics since MacConaill's time, and some other matters.

  2. Biomechanical comparison between bicortical pin and monocortical screw/polymethylmethacrylate constructs in the cadaveric canine cervical vertebral column.

    PubMed

    Hettlich, Bianca F; Allen, Matthew J; Pascetta, Daniel; Fosgate, Geoffrey T; Litsky, Alan S

    2013-08-01

    To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. Biomechanical cadaver study. Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletally mature dogs (weighing 22-32 kg). Specimens were radiographed and examined by dual energy X-ray absorptiometry. Stiffness of the unaltered C4-C5 intervertebral motion unit was measured in extension, flexion and lateral bending using non-destructive 4-point bend testing. Specimens were then stabilized by (1) bicortical stainless steel pins/PMMA, (2) monocortical stainless steel screws/PMMA, or (3) monocortical titanium screws/PMMA. Mechanical testing was repeated and stiffness data from unaltered specimens and the 3 treatment groups were compared. All 3 surgical methods significantly increased stiffness of the C4-C5 motion unit compared with the unaltered specimen (P < .001 for all treatments), but stiffness was not significantly different among the 3 fixation groups (P = .578). In this model, monocortical screw fixation (with stainless steel or titanium screws) was biomechanically equivalent to bicortical fixation. © Copyright 2013 by The American College of Veterinary Surgeons.

  3. Biomechanical implications of walking with indigenous footwear.

    PubMed

    Willems, Catherine; Stassijns, Gaetane; Cornelis, Wim; D'Août, Kristiaan

    2017-04-01

    This study investigates biomechanical implications of walking with indigenous "Kolhapuri" footwear compared to barefoot walking among a population of South Indians. Ten healthy adults from South India walked barefoot and indigenously shod at voluntary speed on an artificial substrate. The experiment was repeated outside, on a natural substrate. Data were collected from (1) a heel-mounted 3D-accelerometer recording peak impact at heel contact, (2) an ankle-mounted 3D-goniometer (plantar/dorsiflexion and inversion/eversion), and (3) sEMG electrodes at the m. tibialis anterior and the m. gastrocnemius medialis. Data show that the effect of indigenous footwear on the measured variables, compared to barefoot walking, is relatively small and consistent between substrates (even though subjects walked faster on the natural substrate). Walking barefoot, compared to shod walking yields higher impact accelerations, but the differences are small and only significant for the artificial substrate. The main rotations of the ankle joint are mostly similar between conditions. Only the shod condition shows a faster ankle rotation over the rapid eversion motion on the natural substrate. Maximal dorsiflexion in late stance differs between the footwear conditions on an artificial substrate, with the shod condition involving a less dorsiflexed ankle, and the plantar flexion at toe-off is more extreme when shod. Overall the activity pattern of the external foot muscles is similar. The indigenous footwear studied (Kolhapuri) seems to alter foot biomechanics only in a subtle way. While offering some degree of protection, walking in this type of footwear resembles barefoot gait and this type of indigenous footwear might be considered "minimal". © 2017 The Authors American Journal of Physical Anthropology Published by Wiley Periodicals, Inc.

  4. Biomechanical analysis on stent materials used as cardiovascular implants

    NASA Astrophysics Data System (ADS)

    Kumar, Vasantha; Ramesha, C. M.; Sajjan, Sudheer S.

    2018-04-01

    Atherosclerosis is the most common cause of death in the world, accounting for 48% of all deaths in the world. Atherosclerosis, also known as coronary artery disease occurs when excess cholesterol attaches itself to the walls of blood vessels. Coronary stent implantation is one of the most important procedures to treating coronary artery disease such atherosclerosis. Due to its efficiency, flexibility and simplicity, the use of coronary stents procedures has increased rapidly. In order to have better output of stent implantation, it is needed to study and analyze the biomechanical behavior of this device before manufacturing and put into use. Biomaterials are commonly used for medical application in cardiovascular stent implantation. A biomaterial is a non-viable material used as medical implant, so it is intended to interact with biological system. In this paper, an explicit dynamic analysis is used for analyzing the biomechanical behavior of cardiovascular stent by using finite element analysis tool, ABAQUS 6.10. Results showed that a best suitable biomaterial for cardiovascular stent implants, which exhibits an outstanding biocompatibility and biomechanical characteristics will be aimed at which will be quite useful to the human beings worldwide.

  5. Cell biomechanics and its applications in human disease diagnosis

    NASA Astrophysics Data System (ADS)

    Nematbakhsh, Yasaman; Lim, Chwee Teck

    2015-04-01

    Certain diseases are known to cause changes in the physical and biomechanical properties of cells. These include cancer, malaria, and sickle cell anemia among others. Typically, such physical property changes can result in several fold increases or decreases in cell stiffness, which are significant and can result in severe pathology and eventual catastrophic breakdown of the bodily functions. While there are developed biochemical and biological assays to detect the onset or presence of diseases, there is always a need to develop more rapid, precise, and sensitive methods to detect and diagnose diseases. Biomechanical property changes can play a significant role in this regard. As such, research into disease biomechanics can not only give us an in-depth knowledge of the mechanisms underlying disease progression, but can also serve as a powerful tool for detection and diagnosis. This article provides some insights into opportunities for how significant changes in cellular mechanical properties during onset or progression of a disease can be utilized as useful means for detection and diagnosis. We will also showcase several technologies that have already been developed to perform such detection and diagnosis.

  6. High-performance spider webs: integrating biomechanics, ecology and behaviour

    PubMed Central

    Harmer, Aaron M. T.; Blackledge, Todd A.; Madin, Joshua S.; Herberstein, Marie E.

    2011-01-01

    Spider silks exhibit remarkable properties, surpassing most natural and synthetic materials in both strength and toughness. Orb-web spider dragline silk is the focus of intense research by material scientists attempting to mimic these naturally produced fibres. However, biomechanical research on spider silks is often removed from the context of web ecology and spider foraging behaviour. Similarly, evolutionary and ecological research on spiders rarely considers the significance of silk properties. Here, we highlight the critical need to integrate biomechanical and ecological perspectives on spider silks to generate a better understanding of (i) how silk biomechanics and web architectures interacted to influence spider web evolution along different structural pathways, and (ii) how silks function in an ecological context, which may identify novel silk applications. An integrative, mechanistic approach to understanding silk and web function, as well as the selective pressures driving their evolution, will help uncover the potential impacts of environmental change and species invasions (of both spiders and prey) on spider success. Integrating these fields will also allow us to take advantage of the remarkable properties of spider silks, expanding the range of possible silk applications from single threads to two- and three-dimensional thread networks. PMID:21036911

  7. Process for the reconstruction of three-dimensional images of an area of interest of an object comprising the combination of measurements over the entire object with measurements of an area of interest of said object, and appropriate installation

    DOEpatents

    Azevedo, Stephen; Grangeat, Pierre; Rizo, Philippe

    1995-01-01

    Process and installation making it possible to reconstitute precise images of an area of interest (2) of an object (1) by reducing the errors produced by the contribution of the compliment of the object. A first series of measurements is carried out, where a conical beam (10) only takes in the area of interest of the object (2) and this is followed by a second series of measurements in which the beam takes in the entire object. A combination of the measurements of the two series is carried out in order to make them compatible and obtain a more accurate image of the area of interest (2).

  8. Single-row modified mason-allen versus double-row arthroscopic rotator cuff repair: a biomechanical and surface area comparison.

    PubMed

    Nelson, Cory O; Sileo, Michael J; Grossman, Mark G; Serra-Hsu, Frederick

    2008-08-01

    The purpose of this study was to compare the time-zero biomechanical strength and the surface area of repair between a single-row modified Mason-Allen rotator cuff repair and a double-row arthroscopic repair. Six matched pairs of sheep infraspinatus tendons were repaired by both techniques. Pressure-sensitive film was used to measure the surface area of repair for each configuration. Specimens were biomechanically tested with cyclic loading from 20 N to 30 N for 20 cycles and were loaded to failure at a rate of 1 mm/s. Failure was defined at 5 mm of gap formation. Double-row suture anchor fixation restored a mean surface area of 258.23 +/- 69.7 mm(2) versus 148.08 +/- 75.5 mm(2) for single-row fixation, a 74% increase (P = .025). Both repairs had statistically similar time-zero biomechanics. There was no statistical difference in peak-to-peak displacement or elongation during cyclic loading. Single-row fixation showed a higher mean load to failure (110.26 +/- 26.4 N) than double-row fixation (108.93 +/- 21.8 N). This was not statistically significant (P = .932). All specimens failed at the suture-tendon interface. Double-row suture anchor fixation restores a greater percentage of the anatomic footprint when compared with a single-row Mason-Allen technique. The time-zero biomechanical strength was not significantly different between the 2 study groups. This study suggests that the 2 factors are independent of each other. Surface area and biomechanical strength of fixation are 2 independent factors in the outcome of rotator cuff repair. Maximizing both factors may increase the likelihood of complete tendon-bone healing and ultimately improve clinical outcomes. For smaller tears, a single-row modified Mason-Allen suture technique may provide sufficient strength, but for large amenable tears, a double row can provide both strength and increased surface area for healing.

  9. Biomechanical adaptations of mice cortical bone submitted to three different exercise modalities

    PubMed Central

    Frajacomo, Fernando Tadeu Trevisan; Falcai, Maurício José; Fernandes, Cleverson Rodrigues; Shimano, Antonio Carlos; Garcia, Sérgio Britto

    2013-01-01

    Objective To compare the adaptive effects of three non-weight bearing exercise on bone mechanical properties. Methods 24 male Balb/c mice (22-25g), were randomly divided into four groups (n=6): sedentary group (S); swimming group (N) which performed sessions five times per week for 60 min progressively; resistance group (R), which performed climbing exercise with progressive load, three times per week; and combined group (C), which performed the same protocols aforementioned being three times a week according to N protocol and two times a week the R protocol during eight weeks. Biomechanical tests, load until failure and stiffness evaluation of shinbone was performed after animals have been sacrificed. Results Stiffness values were statistically higher only in the isolated modalities groups (N and R, 41.68 ± 10.43 and 41.21 ± 11.38 N/mm, respectively) compared with the S group (28.48 ± 7.34 N/mm). However, taking into consideration the final body mass, relative values, there was no difference in the biomechanical tests among the groups. Conclusion Data from the present investigation demonstrated a favorable influence of muscle contraction in lower impact isolated exercise modalities on absolute stiffness values, i.e.groups N and R, whereas the combined group (C) did not present any statistical significant difference compared to sedentary group. Level of Evidence II, Prospective Comparative Study. PMID:24453691

  10. Objective measurement of bread crumb texture

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Coles, Graeme D.

    1995-01-01

    Evaluation of bread crumb texture plays an important role in judging bread quality. This paper discusses the application of image analysis methods to the objective measurement of the visual texture of bread crumb. The application of Fast Fourier Transform and mathematical morphology methods have been discussed by the authors in their previous work, and a commercial bread texture measurement system has been developed. Based on the nature of bread crumb texture, we compare the advantages and disadvantages of the two methods, and a third method based on features derived directly from statistics of edge density in local windows of the bread image. The analysis of various methods and experimental results provides an insight into the characteristics of the bread texture image and interconnection between texture measurement algorithms. The usefulness of the application of general stochastic process modelling of texture is thus revealed; it leads to more reliable and accurate evaluation of bread crumb texture. During the development of these methods, we also gained useful insights into how subjective judges form opinions about bread visual texture. These are discussed here.

  11. A motor learning approach to training wheelchair propulsion biomechanics for new manual wheelchair users: A pilot study.

    PubMed

    Morgan, Kerri A; Tucker, Susan M; Klaesner, Joseph W; Engsberg, Jack R

    2017-05-01

    Developing an evidence-based approach to teaching wheelchair skills and proper propulsion for everyday wheelchair users with a spinal cord injury (SCI) is important to their rehabilitation. The purpose of this project was to pilot test manual wheelchair training based on motor learning and repetition-based approaches for new manual wheelchair users with an SCI. A repeated measures within-subject design was used with participants acting as their own controls. Six persons with an SCI requiring the use of a manual wheelchair participated in wheelchair training. The training included nine 90-minute sessions. The primary focus was on wheelchair propulsion biomechanics with a secondary focus on wheelchair skills. During Pretest 1, Pretest 2, and Posttest, wheelchair propulsion biomechanics were measured using the Wheelchair Propulsion Test and a Video Motion Capture system. During Pretest 2 and Posttest, propulsion forces using the WheelMill System and wheelchair skills using the Wheelchair Skills Test were measured. Significant changes in area of the push loop, hand-to-axle relationship, and slope of push forces were found. Changes in propulsion patterns were identified post-training. No significant differences were found in peak and average push forces and wheelchair skills pre- and post-training. This project identified trends in change related to a repetition-based motor learning approach for propelling a manual wheelchair. The changes found were related to the propulsion patterns used by participants. Despite some challenges associated with implementing interventions for new manual wheelchair users, such as recruitment, the results of this study show that repetition-based training can improve biomechanics and propulsion patterns for new manual wheelchair users.

  12. Biomechanical effects of mobile computer location in a vehicle cab.

    PubMed

    Saginus, Kyle A; Marklin, Richard W; Seeley, Patricia; Simoneau, Guy G; Freier, Stephen

    2011-10-01

    The objective of this research is to determine the best location to place a conventional mobile computer supported by a commercially available mount in a light truck cab. U.S. and Canadian electric utility companies are in the process of integrating mobile computers into their fleet vehicle cabs. There are no publications on the effect of mobile computer location in a vehicle cab on biomechanical loading, performance, and subjective assessment. The authors tested four locations of mobile computers in a light truck cab in a laboratory study to determine how location affected muscle activity of the lower back and shoulders; joint angles of the shoulders, elbows, and wrist; user performance; and subjective assessment. A total of 22 participants were tested in this study. Placing the mobile computer closer to the steering wheel reduced low back and shoulder muscle activity. Joint angles of the shoulders, elbows, and wrists were also closer to neutral angle. Biomechanical modeling revealed substantially less spinal compression and trunk muscle force. In general, there were no practical differences in performance between the locations. Subjective assessment indicated that users preferred the mobile computer to be as close as possible to the steering wheel. Locating the mobile computer close to the steering wheel reduces risk of injuries, such as low back pain and shoulder tendonitis. Results from the study can guide electric utility companies in the installation of mobile computers into vehicle cabs. Results may also be generalized to other industries that use trucklike vehicles, such as construction.

  13. [On evaluating the robot-based experimental system for biomechanical experiment of human knee].

    PubMed

    Deng, Guoyong; Tian, Lianfang; Bai, Bo; Sun, Hui

    2010-02-01

    This is a report on how we use the hybrid force-displacement control method to load the human knee and analyze the effect and value of our robot experimental system through the biomechanical experiments of total meniscal resection of human knee. The whole robot control system can load continuously on the specimens, thus overcoming the shortcomings of the traditional loading methods which can only load discretely. In the meantime, by using the robot-based testing system, the force (torque) of the specimens and the spatial position under the force can be measured in real-time, which overcomes the shortcomings caused by the separation of force (torque) measurement from displacement measurement and so greatly improves the measurement accuracy.

  14. Analysis of occupational stress in a high fashion clothing factory with upper limb biomechanical overload.

    PubMed

    Forcella, Laura; Bonfiglioli, Roberta; Cutilli, Piero; Siciliano, Eugenio; Di Donato, Angela; Di Nicola, Marta; Antonucci, Andrea; Di Giampaolo, Luca; Boscolo, Paolo; Violante, Francesco Saverio

    2012-07-01

    To study job stress and upper limb biomechanical overload due to repetitive and forceful manual activities in a factory producing high fashion clothing. A total of 518 workers (433 women and 85 men) were investigated to determine anxiety, occupational stress (using the Italian version of the Karasek Job Content Questionnaire) and perception of symptoms (using the Italian version of the Somatization scale of Symptom Checklist SCL-90). Biomechanical overload was analyzed using the OCRA Check list. Biomechanical assessment did not reveal high-risk jobs, except for cutting. Although the perception of anxiety and job insecurity was within the normal range, all the workers showed a high level of job strain (correlated with the perception of symptoms) due to very low decision latitude. Occupational stress resulted partially in line with biomechanical risk factors; however, the perception of low decision latitude seems to play a major role in determining job strain. Interactions between physical and psychological factors cannot be demonstrated. Anyway, simultaneous long-term monitoring of occupational stress features and biomechanical overload could guide workplace interventions aimed at reducing the risk of adverse health effects.

  15. Adaptations in single-leg hop biomechanics following anterior cruciate ligament reconstruction.

    PubMed

    Orishimo, Karl F; Kremenic, Ian J; Mullaney, Michael J; McHugh, Malachy P; Nicholas, Stephen J

    2010-11-01

    When a patient performs a clinically normal hop test based on distance, it cannot be assumed that the biomechanics are similar between limbs. The objective was to compare takeoff and landing biomechanics between legs in patients who have undergone anterior cruciate ligament reconstruction. Kinematics and ground reaction forces were recorded as 13 patients performed the single-leg hop on each leg. Distance hopped, joint range of motion, peak joint kinetics and the peak total extensor moment were compared between legs during both takeoff and landing. Average hop distance ratio (involved/noninvolved) was 93 ± 4%. Compared to the noninvolved side, knee motion during takeoff on the involved side was significantly reduced (P = 0.008). Peak moments and powers on the involved side were lower at the knee and higher at the ankle and hip compared with the noninvolved side (Side by Joint P = 0.011; P = 0.003, respectively). The peak total extensor moment was not different between legs (P = 0.305) despite a decrease in knee moment and increases in ankle and hip moments (Side by Joint P = 0.015). During landing, knee motion was reduced (P = 0.043), and peak power absorbed was decreased at the knee and hip and increased at the ankle on the involved side compared to the noninvolved side (P = 0.003). The compensations by other joints may indicate protective adaptations to avoid overloading the reconstructed knee.

  16. Biomechanical Concepts for the Physical Educator

    ERIC Educational Resources Information Center

    Strohmeyer, H. Scott

    2004-01-01

    The concepts and principles of biomechanics are familiar to the teacher of physical science as well as to the physical educator. The difference between the two instructors, however, is that one knows the language of science and the other provides an experientially rich environment to support acquisition of these concepts and principles. Use of…

  17. Correlation Between Biomechanical Responses of Posterior Sclera and IOP Elevations During Micro Intraocular Volume Change

    PubMed Central

    Morris, Hugh J.; Tang, Junhua; Cruz Perez, Benjamin; Pan, Xueliang; Hart, Richard T.; Weber, Paul A.; Liu, Jun

    2013-01-01

    Purpose. This study tested the hypothesis that intraocular pressure (IOP) elevations, induced by controlled increase of intraocular volume, are correlated with the biomechanical responses of the posterior sclera. Methods. Porcine globes were tested within 48 hours postmortem. The first group of globes (n = 11) was infused with 15 μL of phosphate-buffered saline at three different rates to investigate rate-dependent IOP elevations. The second group (n = 16) was first infused at the fast rate and then underwent inflation tests to investigate the relationship between IOP elevations (ΔIOP) and scleral strains. The strains in the superotemporal region of the posterior sclera were measured by ultrasound speckle tracking. Linear regression was used to examine the association between ΔIOP due to micro-volumetric infusion and the scleral strains at a specific inflation pressure. Results. The average ΔIOP was 14.9 ± 4.3 mm Hg for the infusion of 15 μL in 1 second. The ΔIOP was greater for the faster infusion rates but highly correlated across different rates (P < 0.001). A significant negative association was found between the ΔIOP and the tangential strains in both the circumferential (R2 = 0.54, P = 0.003) and meridian (R2 = 0.53, P = 0.002) directions in the posterior sclera. Conclusions. This study showed a substantial increase in IOP, with a large intersubject variance during micro-volumetric change. A stiffer response of the sclera was associated with larger IOP spikes, providing experimental evidence linking corneoscleral biomechanics to IOP fluctuation. In vivo measurement of corneoscleral biomechanics may help better predict the dynamic profile of IOP. PMID:24130185

  18. Posterior cruciate ligament: anatomy, biomechanics, and outcomes.

    PubMed

    Voos, James E; Mauro, Craig S; Wente, Todd; Warren, Russell F; Wickiewicz, Thomas L

    2012-01-01

    The optimal treatment of posterior cruciate ligament ruptures remains controversial despite numerous recent basic science advances on the topic. The current literature on the anatomy, biomechanics, and clinical outcomes of posterior cruciate ligament reconstruction is reviewed. Recent studies have quantified the anatomic location and biomechanical contribution of each of the 2 posterior cruciate ligament bundles on tunnel placement and knee kinematics during reconstruction. Additional laboratory and cadaveric studies have suggested double-bundle reconstructions of the posterior cruciate ligament may better restore normal knee kinematics than single-bundle reconstructions although clinical outcomes have not revealed such a difference. Tibial inlay posterior cruciate ligament reconstructions (either open or arthroscopic) are preferred by many authors to avoid the "killer turn" and graft laxity with cyclic loading. Posterior cruciate ligament reconstruction improves subjective patient outcomes and return to sport although stability and knee kinematics may not return to normal.

  19. Performance Measurement and Investment Objectives for Educational Endowment Funds.

    ERIC Educational Resources Information Center

    Williamson, J. Peter

    This book is one of a series of projects developed to increase understanding of the management of educational endowment funds. Specifics of performance measurement and the setting of objectives are emphasized. Part one deals with measurement of the rate of return, or profitability, of an endowment fund. Part two reviews some statistical measures…

  20. Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews

    PubMed Central

    Yun, Soon-Dong; Choi, Sung-Hwan; Cha, Jung-Yul; Yu, Hyung-Seog; Kim, Kwang-Mahn; Kim, Jin

    2017-01-01

    Objective The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone–implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect. PMID:28670565