Liquid Crystal Spatial Light Modulators for Simulating Zonal Multifocal Lenses.
Li, Yiyu; Bradley, Arthur; Xu, Renfeng; Kollbaum, Pete S
2017-09-01
To maximize efficiency of the normally lengthy and costly multizone lens design and testing process, it is advantageous to evaluate the potential efficacy of a design as thoroughly as possible prior to lens fabrication and on-eye testing. The current work describes an ex vivo approach of optical design testing. The aim of this study was to describe a system capable of examining the optical characteristics of multizone bifocal and multifocal optics by subaperture stitching using liquid crystal technologies. A liquid crystal spatial light modulator (SLM) was incorporated in each of two channels to generate complementary subapertures by amplitude modulation. Additional trial lenses and phase plates were placed in pupil conjugate planes of either channel to integrate the desired bifocal and multifocal optics once the two optical paths were recombined. A high-resolution Shack-Hartmann aberrometer was integrated to measure the optics of the dual-channel system. Power and wavefront error maps as well as point spread functions were measured and computed for each of three multizone multifocal designs. High transmission modulation was achieved by introducing half-wavelength optical path differences to create two- and five-zone bifocal apertures. Dual-channel stitching revealed classic annular rings in the point spread functions generated from two-zone designs when the outer annular optic was defocused. However, low efficiency of the SLM prevented us from simultaneously measuring the eye + simulator aberrations, and the higher-order diffraction patterns generated by the cellular structure of the liquid crystal arrays limited the visual field to ±0.45 degrees. The system successfully simulated bifocal and multifocal simultaneous lenses allowing for future evaluation of both objective and subjective evaluation of complex optical designs. However, low efficiency and diffraction phenomena of the SLM limit the utility of this technology for simulating multizone and multifocal optics.
Multifocal planes head-mounted displays.
Rolland, J P; Krueger, M W; Goon, A
2000-07-01
Stereoscopic head-mounted displays (HMD's) provide an effective capability to create dynamic virtual environments. For a user of such environments, virtual objects would be displayed ideally at the appropriate distances, and natural concordant accommodation and convergence would be provided. Under such image display conditions, the user perceives these objects as if they were objects in a real environment. Current HMD technology requires convergent eye movements. However, it is currently limited by fixed visual accommodation, which is inconsistent with real-world vision. A prototype multiplanar volumetric projection display based on a stack of laminated planes was built for medical visualization as discussed in a paper presented at a 1999 Advanced Research Projects Agency workshop (Sullivan, Advanced Research Projects Agency, Arlington, Va., 1999). We show how such technology can be engineered to create a set of virtual planes appropriately configured in visual space to suppress conflicts of convergence and accommodation in HMD's. Although some scanning mechanism could be employed to create a set of desirable planes from a two-dimensional conventional display, multiplanar technology accomplishes such function with no moving parts. Based on optical principles and human vision, we present a comprehensive investigation of the engineering specification of multiplanar technology for integration in HMD's. Using selected human visual acuity and stereoacuity criteria, we show that the display requires at most 27 equally spaced planes, which is within the capability of current research and development display devices, located within a maximal 26-mm-wide stack. We further show that the necessary in-plane resolution is of the order of 5 microm.
A reflection TIE system for 3D inspection of wafer structures
NASA Astrophysics Data System (ADS)
Yan, Yizhen; Qu, Weijuan; Yan, Lei; Wang, Zhaomin; Zhao, Hongying
2017-10-01
A reflection TIE system consisting of a reflecting microscope and a 4f relay system is presented in this paper, with which the transport of intensity equation (TIE) is applied to reconstruct the three-dimensional (3D) profile of opaque micro objects like wafer structures for 3D inspection. As the shape of an object can affect the phases of waves, the 3D information of the object can be easily acquired with the multiple phases at different refocusing planes. By electronically controlled refocusing, multi-focal images can be captured and used in solving TIE to obtain the phase and depth of the object. In order to validate the accuracy and efficiency of the proposed system, the phase and depth values of several samples are calculated, and the experimental results is presented to demonstrate the performance of the system.
[Multifocal visual electrophysiology in visual function evaluation].
Peng, Shu-Ya; Chen, Jie-Min; Liu, Rui-Jue; Zhou, Shu; Liu, Dong-Mei; Xia, Wen-Tao
2013-08-01
Multifocal visual electrophysiology, consisting of multifocal electroretinography (mfERG) and multifocal visual evoked potential (mfVEP), can objectively evaluate retina function and retina-cortical conduction pathway status by stimulating many local retinal regions and obtaining each local response simultaneously. Having many advantages such as short testing time and high sensitivity, it has been widely used in clinical ophthalmology, especially in the diagnosis of retinal disease and glaucoma. It is a new objective technique in clinical forensic medicine involving visual function evaluation of ocular trauma in particular. This article summarizes the way of stimulation, the position of electrodes, the way of analysis, the visual function evaluation of mfERG and mfVEP, and discussed the value of multifocal visual electrophysiology in forensic medicine.
Evaluation of Hydroxychloroquine Retinopathy With Multifocal Electroretinography
So, Scott C.; Hedges, Thomas R.; Schuman, Joel S.; Quireza, Maria Luz Amaro
2007-01-01
BACKGROUND AND OBJECTIVE To describe the changes revealed by multifocal electroretinography (ERG) in patients taking hydroxychloroquine. PATIENTS AND METHODS Six patients being treated for various inflammatory conditions with hydroxychloroquine for periods ranging from 8 months to 7 years were consecutively evaluated. Each examination included measurement of Snellen visual acuities, Amsler grid assessment, and automated visual field testing. In some cases, funduscopic examinations were complimented by photography and fluorescein angiography. Multifocal ERG was performed for all patients. RESULTS Three patients (six eyes) were found to have distinctive abnormalities on multifocal ERG consisting of pericentral depression of ERG signals. The abnormalities on multifocal ERG corresponded with the patients’ subjective descriptions and the visual field depiction of their pericentral scotomas. All affected patients had been taking hydroxychloroquine for at least 7 years. One patient with generalized depression on multifocal ERG had possible hydroxychloroquine retinopathy. Two patients (three eyes) had relatively normal results on multifocal ERG. CONCLUSION Multifocal ERG objectively demonstrates depression of signals in the perifoveal region in visually symptomatic patients with long-term hydroxychloroquine use. Even patients with normal visual acuity and no fundus abnormalities can have abnormal results. Although we have not yet identified patients with abnormalities on multifocal ERG before the onset of symptoms, multifocal ERG may be useful in monitoring patients at risk and may provide an earlier opportunity to identify maculopathy. PMID:12757106
An information-theoretic approach to designing the plane spacing for multifocal plane microscopy
Tahmasbi, Amir; Ram, Sripad; Chao, Jerry; Abraham, Anish V.; Ward, E. Sally; Ober, Raimund J.
2015-01-01
Multifocal plane microscopy (MUM) is a 3D imaging modality which enables the localization and tracking of single molecules at high spatial and temporal resolution by simultaneously imaging distinct focal planes within the sample. MUM overcomes the depth discrimination problem of conventional microscopy and allows high accuracy localization of a single molecule in 3D along the z-axis. An important question in the design of MUM experiments concerns the appropriate number of focal planes and their spacings to achieve the best possible 3D localization accuracy along the z-axis. Ideally, it is desired to obtain a 3D localization accuracy that is uniform over a large depth and has small numerical values, which guarantee that the single molecule is continuously detectable. Here, we address this concern by developing a plane spacing design strategy based on the Fisher information. In particular, we analyze the Fisher information matrix for the 3D localization problem along the z-axis and propose spacing scenarios termed the strong coupling and the weak coupling spacings, which provide appropriate 3D localization accuracies. Using these spacing scenarios, we investigate the detectability of the single molecule along the z-axis and study the effect of changing the number of focal planes on the 3D localization accuracy. We further review a software module we recently introduced, the MUMDesignTool, that helps to design the plane spacings for a MUM setup. PMID:26113764
Multifocal necrotising fasciitis: an overlooked entity?
El-Khani, Ussamah; Nehme, Jean; Darwish, Ammar; Jamnadas-Khoda, Benjamin; Scerri, Godwin; Heppell, Simon; Bennett, Nicholas
2012-04-01
The aim of the study is to report a case of multi-focal necrotising fasciitis, review research on this subject to identify common aetiological factors and highlight suggestions to improve management. Necrotising fasciitis is a severe, life-threatening soft tissue infection that typically arises from a single area, usually secondary to a minor penetrating injury. Multi-focal necrotising fasciitis, where there is more than one non-contiguous area of necrosis, is much less commonly reported. There are no guidelines specific to the management of multi-focal necrotising fasciitis, and its under-reporting may lead to missed management opportunities. A systematic literature review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) protocol. A search of MEDLINE, OLD MEDLINE and the Cochrane Collaboration was performed from 1966 to March 2011 using 16 search terms. All articles were screened for genuine non-contiguous multi-focal necrotising fasciitis. Of the papers that met this criterion, data on patient demographics, likely inciting injury, presentation time-line, microbial agents, sites affected, objective assessment scores, treatment and outcome were extracted. A total of 31 studies met our inclusion criteria and 33 individual cases of multi-focal necrotising fasciitis were included in the quantitative analysis. About half (52%) of cases were type II necrotising fasciitis; 42% of cases had identifiable inciting injuries; 21% of cases developed multi-focal lesions non-synchronously, of which 86% were type II. Nearly all (94%) of cases had incomplete objective assessment scores. One case identified inflammatory imaging findings prior to clinical necrosis. Multifocality in necrotising fasciitis is likely to be associated with type II disease. We postulate that validated objective tools will aid necrotising fasciitis management pathways that will identify high-risk groups for multifocality and advise early pre-emptive imaging. We recommend the adoption of regional multi-focal necrotising fasciitis registers. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Double peacock eye optical element for extended focal depth imaging with ophthalmic applications.
Romero, Lenny A; Millán, María S; Jaroszewicz, Zbigniew; Kolodziejczyk, Andrzej
2012-04-01
The aged human eye is commonly affected by presbyopia, and therefore, it gradually loses its capability to form images of objects placed at different distances. Extended depth of focus (EDOF) imaging elements can overcome this inability, despite the introduction of a certain amount of aberration. This paper evaluates the EDOF imaging performance of the so-called peacock eye phase diffractive element, which focuses an incident plane wave into a segment of the optical axis and explores the element's potential use for ophthalmic presbyopia compensation optics. Two designs of the element are analyzed: the single peacock eye, which produces one focal segment along the axis, and the double peacock eye, which is a spatially multiplexed element that produces two focal segments with partial overlapping along the axis. The performances of the peacock eye elements are compared with those of multifocal lenses through numerical simulations as well as optical experiments in the image space. The results demonstrate that the peacock eye elements form sharper images along the focal segment than the multifocal lenses and, therefore, are more suitable for presbyopia compensation. The extreme points of the depth of field in the object space, which represent the remote and the near object points, have been experimentally obtained for both the single and the double peacock eye optical elements. The double peacock eye element has better imaging quality for relatively short and intermediate distances than the single peacock eye, whereas the latter seems better for far distance vision.
Creation of diffraction-limited non-Airy multifocal arrays using a spatially shifted vortex beam
NASA Astrophysics Data System (ADS)
Lin, Han; Gu, Min
2013-02-01
Diffraction-limited non-Airy multifocal arrays are created by focusing a phase-modulated vortex beam through a high numerical-aperture objective. The modulated phase at the back aperture of the objective resulting from the superposition of two concentric phase-modulated vortex beams allows for the generation of a multifocal array of cylindrically polarized non-Airy patterns. Furthermore, we shift the spatial positions of the phase vortices to manipulate the intensity distribution at each focal spot, leading to the creation of a multifocal array of split-ring patterns. Our method is experimentally validated by generating the predicted phase modulation through a spatial light modulator. Consequently, the spatially shifted circularly polarized vortex beam adopted in a dynamic laser direct writing system facilitates the fabrication of a split-ring microstructure array in a polymer material by a single exposure of a femtosecond laser beam.
Horn, Folkert K; Kaltwasser, Christoph; Jünemann, Anselm G; Kremers, Jan; Tornow, Ralf P
2012-04-01
There is evidence that multifocal visual evoked potentials (VEPs) can be used as an objective tool to detect visual field loss. The aim of this study was to correlate multifocal VEP amplitudes with standard perimetry data and retinal nerve fibre layer (RNFL) thickness. Multifocal VEP recordings were performed with a four-channel electrode array using 58 stimulus fields (pattern reversal dartboard). For each field, the recording from the channel with maximal signal-to-noise ratio (SNR) was retained, resulting in an SNR optimised virtual recording. Correlation with RNFL thickness, measured with spectral domain optical coherence tomography and with standard perimetry, was performed for nerve fibre bundle related areas. The mean amplitudes in nerve fibre related areas were smaller in glaucoma patients than in normal subjects. The differences between both groups were most significant in mid-peripheral areas. Amplitudes in these areas were significantly correlated with corresponding RNFL thickness (Spearman R=0.76) and with standard perimetry (R=0.71). The multifocal VEP amplitude was correlated with perimetric visual field data and the RNFL thickness of the corresponding regions. This method of SNR optimisation is useful for extracting data from recordings and may be appropriate for objective assessment of visual function at different locations. This study has been registered at http://www.clinicaltrials.gov (NCT00494923).
The number of seizures needed in the EMU
Struck, Aaron F.; Cole, Andrew J.; Cash, Sydney S.; Westover, M. Brandon
2016-01-01
Summary Objective The purpose of this study was to develop a quantitative framework to estimate the likelihood of multifocal epilepsy based on the number of unifocal seizures observed in the epilepsy monitoring unit (EMU). Methods Patient records from the EMU at Massachusetts General Hospital (MGH) from 2012 to 2014 were assessed for the presence of multifocal seizures as well the presence of multifocal interictal discharges and multifocal structural imaging abnormalities during the course of the EMU admission. Risk factors for multifocal seizures were assessed using sensitivity and specificity analysis. A Kaplan-Meier survival analysis was used to estimate the risk of multifocal epilepsy for a given number of consecutive seizures. To overcome the limits of the Kaplan-Meier analysis, a parametric survival function was fit to the EMU subjects with multifocal seizures and this was used to develop a Bayesian model to estimate the risk of multifocal seizures during an EMU admission. Results Multifocal interictal discharges were a significant predictor of multifocal seizures within an EMU admission with a p < 0.01, albeit with only modest sensitivity 0.74 and specificity 0.69. Multifocal potentially epileptogenic lesions on MRI were not a significant predictor p = 0.44. Kaplan-Meier analysis was limited by wide confidence intervals secondary to significant patient dropout and concern for informative censoring. The Bayesian framework provided estimates for the number of unifocal seizures needed to predict absence of multifocal seizures. To achieve 90% confidence for the absence of multifocal seizure, three seizures are needed when the pretest probability for multifocal epilepsy is 20%, seven seizures for a pretest probability of 50%, and nine seizures for a pretest probability of 80%. Significance These results provide a framework to assist clinicians in determining the utility of trying to capture a specific number of seizures in EMU evaluations of candidates for epilepsy surgery. PMID:26222350
Visual Acuity and Over-refraction in Myopic Children Fitted with Soft Multifocal Contact Lenses.
Schulle, Krystal L; Berntsen, David A; Sinnott, Loraine T; Bickle, Katherine M; Gostovic, Anita T; Pierce, Gilbert E; Jones-Jordan, Lisa A; Mutti, Donald O; Walline, Jeffrey J
2018-04-01
Practitioners fitting contact lenses for myopia control frequently question whether a myopic child can achieve good vision with a high-add multifocal. We demonstrate that visual acuity is not different than spectacles with a commercially available, center-distance soft multifocal contact lens (MFCL) (Biofinity Multifocal "D"; +2.50 D add). To determine the spherical over-refraction (SOR) necessary to obtain best-corrected visual acuity (BCVA) when fitting myopic children with a center-distance soft MFCL. Children (n = 294) aged 7 to 11 years with myopia (spherical component) of -0.75 to -5.00 diopters (D) (inclusive) and 1.00 D cylinder or less (corneal plane) were fitted bilaterally with +2.50 D add Biofinity "D" MFCLs. The initial MFCL power was the spherical equivalent of a standardized subjective refraction, rounded to the nearest 0.25 D step (corneal plane). An SOR was performed monocularly (each eye) to achieve BCVA. Binocular, high-contrast logMAR acuity was measured with manifest spectacle correction and MFCLs with over-refraction. Photopic pupil size was measured with a pupilometer. The mean (±SD) age was 10.3 ± 1.2 years, and the mean (±SD) SOR needed to achieve BCVA was OD: -0.61 ± 0.24 D/OS: -0.58 ± 0.27 D. There was no difference in binocular high-contrast visual acuity (logMAR) between spectacles (-0.01 ± 0.06) and best-corrected MFCLs (-0.01 ± 0.07) (P = .59). The mean (±SD) photopic pupil size (5.4 ± 0.7 mm) was not correlated with best MFCL correction or the over-refraction magnitude (both P ≥ .09). Children achieved BCVA with +2.50 D add MFCLs that was not different than with spectacles. Children typically required an over-refraction of -0.50 to -0.75 D to achieve BCVA. With a careful over-refraction, these +2.50 D add MFCLs provide good distance acuity, making them viable candidates for myopia control.
Multifocal sensory demyelinating neuropathy: Report of a case.
Oh, Shin J
2017-10-01
Multifocal sensory demyelinating neuropathy has not been adequately reported in the literature. A 42-year-old man with numbness of the left hand for 3 years and of the right hand for 6 months had a pure multifocal sensory neuropathy involving both hands, most prominently affecting 2-point discrimination, number writing, and object recognition of the left hand. Near-nerve needle sensory and mixed nerve conduction studies were performed on the left ulnar nerve. Studies of the left ulnar nerve documented a demyelinating neuropathy characterized by temporal dispersion and marked decrease in the amplitudes of the sensory and mixed compound nerve potentials in the above-elbow-axilla segment. With intravenous immunoglobulin treatment, there was improvement in his neuropathic condition. In this study I describe a case of multifocal sensory demyelinating neuropathy as a counterpart of multifocal motor neuropathy. Muscle Nerve 56: 825-828, 2017. © 2016 Wiley Periodicals, Inc.
Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun
2018-06-01
To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.
Pedrotti, Emilio; Carones, Francesco; Aiello, Francesco; Mastropasqua, Rodolfo; Bruni, Enrico; Bonacci, Erika; Talli, Pietro; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio
2018-02-01
To compare the visual acuity, refractive outcomes, and quality of vision in patients with bilateral implantation of 4 intraocular lenses (IOLs). Department of Neurosciences, Biomedicine and Movement Sciences, Eye Clinic, University of Verona, Verona, and Carones Ophthalmology Center, Milano, Italy. Prospective case series. The study included patients who had bilateral cataract surgery with the implantation of 1 of 4 IOLs as follows: Tecnis 1-piece monofocal (monofocal IOL), Tecnis Symfony extended range of vision (extended-range-of-vision IOL), Restor +2.5 diopter (D) (+2.5 D multifocal IOL), and Restor +3.0 D (+3.0 D multifocal IOL). Visual acuity, refractive outcome, defocus curve, objective optical quality, contrast sensitivity, spectacle independence, and glare perception were evaluated 6 months after surgery. The study comprised 185 patients. The extended-range-of-vision IOL (55 patients) showed better distance visual outcomes than the monofocal IOL (30 patients) and high-addition apodized diffractive-refractive multifocal IOLs (P ≤ .002). The +3.0 D multifocal IOL (50 patients) showed the best near visual outcomes (P < .001). The +2.5 D multifocal IOL (50 patients) and extended-range-of-vision IOL provided significantly better intermediate visual outcomes than the other 2 IOLs, with significantly better vision for a defocus level of -1.5 D (P < .001). Better spectacle independence was shown for the +2.5 D multifocal IOL and extended-range-of-vision IOL (P < .001). The extended-range-of-vision IOL and +2.5 D multifocal IOL provided significantly better intermediate visual restoration after cataract surgery than the monofocal IOL and +3.0 D multifocal IOL, with significantly better quality of vision with the extended-range-of-vision IOL. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Multifocality and Bilaterality of Papillary Thyroid Microcarcinoma
So, Yoon Kyoung; Kim, Myung Woo
2015-01-01
Objectives Papillary thyroid carcinomas frequently occur as two or more separate foci within the thyroid gland (18%-87%). However, those multifocal tumors are easy to be undetected by preoperative radiologic evaluations, which lead to remnant disease after initial surgery. We aimed to study the incidence of multifocal papillary thyroid microcarcinomas (PTMCs), diagnostic accuracy of preoperative radiologic evaluation, predictive factors, and the chance of bilateral tumors. Methods Two hundred and seventy-seven patients with PTMC were included in this study. All patients underwent total thyroidectomy as an initial treatment. Medical records, pathologic reports, and radiological reports were reviewed for analysis. Results Multifocal PTMCs were detected in 100 of 277 patients (36.1%). The mean number of tumors in each patient was 1.6±1.1, ranging from 1 to 10. The additional tumor foci were significantly smaller (0.32±0.18 cm) than the primary tumors (0.63±0.22 cm) (P<0.001). There was no significant relationship between primary tumor size and the presence of contralateral tumors. With more tumors detected in one lobe, there was greater chance of contralateral tumors; 18.8% with single tumor focus, 30.2% with 2 tumor foci, and 46.2% with 3 or more tumor foci in one lobe. Sensitivity of preoperative sonography was 42.7% for multifocal tumors and 49.0% for bilateral tumors. With multivariate analysis, nodular hyperplasia was the only significant factor for multifocal tumors. Conclusion In cases of PTMCs, the incidence of multifocal tumors is high. However, additional tumor foci are too small to be diagnosed preoperatively, especially under the recent guidelines on radiologic screening tests for papillary thyroid carcinoma. Multifocal PTMCs have high risk of bilateral tumors, necessitating more extensive surgery or more thorough follow-up. PMID:26045918
Taxonomy of multi-focal nematode image stacks by a CNN based image fusion approach.
Liu, Min; Wang, Xueping; Zhang, Hongzhong
2018-03-01
In the biomedical field, digital multi-focal images are very important for documentation and communication of specimen data, because the morphological information for a transparent specimen can be captured in form of a stack of high-quality images. Given biomedical image stacks containing multi-focal images, how to efficiently extract effective features from all layers to classify the image stacks is still an open question. We present to use a deep convolutional neural network (CNN) image fusion based multilinear approach for the taxonomy of multi-focal image stacks. A deep CNN based image fusion technique is used to combine relevant information of multi-focal images within a given image stack into a single image, which is more informative and complete than any single image in the given stack. Besides, multi-focal images within a stack are fused along 3 orthogonal directions, and multiple features extracted from the fused images along different directions are combined by canonical correlation analysis (CCA). Because multi-focal image stacks represent the effect of different factors - texture, shape, different instances within the same class and different classes of objects, we embed the deep CNN based image fusion method within a multilinear framework to propose an image fusion based multilinear classifier. The experimental results on nematode multi-focal image stacks demonstrated that the deep CNN image fusion based multilinear classifier can reach a higher classification rate (95.7%) than that by the previous multilinear based approach (88.7%), even we only use the texture feature instead of the combination of texture and shape features as in the previous work. The proposed deep CNN image fusion based multilinear approach shows great potential in building an automated nematode taxonomy system for nematologists. It is effective to classify multi-focal image stacks. Copyright © 2018 Elsevier B.V. All rights reserved.
Programmable diffractive optical elements for extending the depth of focus in ophthalmic optics
NASA Astrophysics Data System (ADS)
Romero, Lenny A.; Millán, María. S.; Jaroszewicz, Zbigniew; Kołodziejczyk, Andrzej
2015-01-01
The depth of focus (DOF) defines the axial range of high lateral resolution in the image space for object position. Optical devices with a traditional lens system typically have a limited DOF. However, there are applications such as in ophthalmology, which require a large DOF in comparison to a traditional optical system, this is commonly known as extended DOF (EDOF). In this paper we explore Programmable Diffractive Optical Elements (PDOEs), with EDOF, as an alternative solution to visual impairments, especially presbyopia. These DOEs were written onto a reflective liquid cystal on silicon (LCoS) spatial light modulator (SLM). Several designs of the elements are analyzed: the Forward Logarithmic Axicon (FLAX), the Axilens (AXL), the Light sword Optical Element (LSOE), the Peacock Eye Optical Element (PE) and Double Peacock Eye Optical Element (DPE). These elements focus an incident plane wave into a segment of the optical axis. The performances of the PDOEs are compared with those of multifocal lenses. In all cases, we obtained the point spread function and the image of an extended object. The results are presented and discussed.
Chromatic multifocal pupillometer for objective early diagnosis of mild cognitive impairment
NASA Astrophysics Data System (ADS)
Rotenstreich, Ygal; Ben-Ner, Daniel; Sharvit-Ginon, Inbal; Ravona-Springer, Ramit; Beeri, Michal; Sher, Ifat
2017-02-01
The pupil responses of 15 cognitively normal subjects (ages 60-74) were examined in response to 76 focal red and blue light stimuli using a chromatic multifocal pupillometer (CMP). Subjects with low cognitive scores as determined as by Montreal Cognitive Assessment testing, presented significantly weaker and sluggish pupil responses in peripheral and central locations of the visual field in response to red and blue light. Our findings suggests that the CMP may present a novel objective, non-invasive, low cost technique for early diagnosis of cognitive decline that may serve for Alzheimer Disease prevention and as sensitive outcome measure of therapeutic effects.
Fast Confocal Raman Imaging Using a 2-D Multifocal Array for Parallel Hyperspectral Detection.
Kong, Lingbo; Navas-Moreno, Maria; Chan, James W
2016-01-19
We present the development of a novel confocal hyperspectral Raman microscope capable of imaging at speeds up to 100 times faster than conventional point-scan Raman microscopy under high noise conditions. The microscope utilizes scanning galvomirrors to generate a two-dimensional (2-D) multifocal array at the sample plane, generating Raman signals simultaneously at each focus of the array pattern. The signals are combined into a single beam and delivered through a confocal pinhole before being focused through the slit of a spectrometer. To separate the signals from each row of the array, a synchronized scan mirror placed in front of the spectrometer slit positions the Raman signals onto different pixel rows of the detector. We devised an approach to deconvolve the superimposed signals and retrieve the individual spectra at each focal position within a given row. The galvomirrors were programmed to scan different focal arrays following Hadamard encoding patterns. A key feature of the Hadamard detection is the reconstruction of individual spectra with improved signal-to-noise ratio. Using polystyrene beads as test samples, we demonstrated not only that our system images faster than a conventional point-scan method but that it is especially advantageous under noisy conditions, such as when the CCD detector operates at fast read-out rates and high temperatures. This is the first demonstration of multifocal confocal Raman imaging in which parallel spectral detection is implemented along both axes of the CCD detector chip. We envision this novel 2-D multifocal spectral detection technique can be used to develop faster imaging spontaneous Raman microscopes with lower cost detectors.
Papadatou, Eleni; Del Águila-Carrasco, Antonio J; Esteve-Taboada, José J; Madrid-Costa, David; Cerviño-Expósito, Alejandro
2017-01-01
To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses. Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed. The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about -3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens. In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient's visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome.
ERIC Educational Resources Information Center
Foley, Nicholas C.; Grossberg, Stephen; Mingolla, Ennio
2012-01-01
How are spatial and object attention coordinated to achieve rapid object learning and recognition during eye movement search? How do prefrontal priming and parietal spatial mechanisms interact to determine the reaction time costs of intra-object attention shifts, inter-object attention shifts, and shifts between visible objects and covertly cued…
Miranda, Jorge; Sandoval, Hugo; Ramos-Duran, Luis; Tonarelli, Silvina B.
2018-01-01
Highly active antiretroviral therapy is well-established in the treatment of human immunodeficiency virus (HIV)-positive patients. Nonadherence with therapy regimens often leads to the occurrence of opportunistic infections that further complicate treatment and challenge the treating physician. We report a young HIV-positive patient who suffered from progressive multifocal leukoencephalopathy caused by the human John Cunningham virus and showed objective clinical improvement after adding mirtazapine to the treatment regimen, an observation that is supported by the emerging literature. PMID:29497578
[Follow-up on MEWDS by fundus perimetry and multifocal ERG with the SLO].
Bültmann, S; Martin, M; Rohrschneider, K
2002-09-01
Most conventional techniques for examination such as perimetry or ERG may not be sensitive enough to detect functional alterations due to MEWDS precisely. We report on a follow-up performed by fundus perimetry and the new technique of multifocal ERG using the scanning laser ophthalmoscope. A 24-year-old female patient (VA 0.2/0.8) was followed up for 7 weeks with these techniques as well as Octopus perimetry, fluorescence angiography, Ganzfeld ERG and biomicroscopy. Multifocal ERG stimulation (mfERG, Retiscan) was performed with the SLO. Visual acuity improved from 0.2 to 0.8 and the central relative scotoma disappeared while a relevant increase of P1-wave amplitudes in mfERG could be observed. Combining objective measurements from the fundus controlled SLO-mfERG and results from fundus perimetry enable good correlation of morphology and results, even for minor alterations of the macula only accessible by few established clinical examinations.
Störmer, Viola S; Winther, Gesche N; Li, Shu-Chen; Andersen, Søren K
2013-03-20
Keeping track of multiple moving objects is an essential ability of visual perception. However, the mechanisms underlying this ability are not well understood. We instructed human observers to track five or seven independent randomly moving target objects amid identical nontargets and recorded steady-state visual evoked potentials (SSVEPs) elicited by these stimuli. Visual processing of moving targets, as assessed by SSVEP amplitudes, was continuously facilitated relative to the processing of identical but irrelevant nontargets. The cortical sources of this enhancement were located to areas including early visual cortex V1-V3 and motion-sensitive area MT, suggesting that the sustained multifocal attentional enhancement during multiple object tracking already operates at hierarchically early stages of visual processing. Consistent with this interpretation, the magnitude of attentional facilitation during tracking in a single trial predicted the speed of target identification at the end of the trial. Together, these findings demonstrate that attention can flexibly and dynamically facilitate the processing of multiple independent object locations in early visual areas and thereby allow for tracking of these objects.
Gagnon, Yakir Luc; Wilby, David; Temple, Shelby Eric
2016-09-01
Light rays of different wavelengths are focused at different distances when they pass through a lens (longitudinal chromatic aberration [LCA]). For animals with color vision this can pose a serious problem, because in order to perceive a sharp image the rays must be focused at the shallow plane of the photoreceptor's outer segments in the retina. A variety of fish and tetrapods have been found to possess multifocal lenses, which correct for LCA by assigning concentric zones to correctly focus specific wavelengths. Each zone receives light from a specific beam entrance position (BEP) (the lateral distance between incoming light and the center of the lens). Any occlusion of incoming light at specific BEPs changes the composition of the wavelengths that are correctly focused on the retina. Here, we calculated the effect of lens position relative to the plane of the iris and light entering the eye at oblique angles on how much of the lens was involved in focusing the image on the retina (measured as the availability of BEPs). We used rotational photography of fish eyes and mathematical modeling to quantify the degree of lens occlusion. We found that, at most lens positions and viewing angles, there was a decrease of BEP availability and in some cases complete absence of some BEPs. Given the implications of these effects on image quality, we postulate that three morphological features (aphakic spaces, curvature of the iris, and intraretinal variability in spectral sensitivity) may, in part, be adaptations to mitigate the loss of spectral image quality in the periphery of the eyes of fishes.
[Halos and multifocal intraocular lenses: origin and interpretation].
Alba-Bueno, F; Vega, F; Millán, M S
2014-10-01
To present the theoretical and experimental characterization of the halo in multifocal intraocular lenses (MIOL). The origin of the halo in a MIOL is the overlaying of 2 or more images. Using geometrical optics, it can be demonstrated that the diameter of each halo depends on the addition of the lens (ΔP), the base power (P(d)), and the diameter of the IOL that contributes to the «non-focused» focus. In the image plane that corresponds to the distance focus, the halo diameter (δH(d)) is given by: δH(d)=d(pn) ΔP/P(d), where d(pn) is the diameter of the IOL that contributes to the near focus. Analogously, in the near image plane the halo diameter (δH(n)) is: δH(n)=d(pd) ΔP/P(d), where d(pd) is the diameter of the IOL that contributes to the distance focus. Patients perceive halos when they see bright objects over a relatively dark background. In vitro, the halo can be characterized by analyzing the intensity profile of the image of a pinhole that is focused by each of the foci of a MIOL. A comparison has been made between the halos induced by different MIOL of the same base power (20D) in an optical bench. As predicted by theory, the larger the addition of the MIOL, the larger the halo diameter. For large pupils and with MIOL with similar aspheric designs and addition (SN6AD3 vs ZMA00), the apodized MIOL has a smaller halo diameter than a non-apodized one in distance vision, while in near vision the size is very similar, but the relative intensity is higher in the apodized MIOL. When comparing lenses with the same diffractive design, but with different spherical-aspheric base design (SN60D3 vs SN6AD3), the halo in distance vision of the spherical MIOL is larger, while in near vision the spherical IOL induces a smaller halo, but with higher intensity due to the spherical aberration of the distance focus in the near image. In the case of a trifocal-diffractive IOL (AT LISA 839MP) the most noticeable characteristic is the double-halo formation due to the 2 non-focused powers. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Rotenstreich, Ygal; Ben-Ner, Daniel; Mahajna, Mohamad; Chibel, Ron; Sher, Ifat
2016-03-01
Purpose: To objectively assess visual field (VF) defects and retinal cell function in healthy subjects and patients with macular degeneration using a chromatic multifocal pupillometer. Methods: A multifocal chromatic pupillometer (MCP) was used to record pupillary responses (PR) of 17 healthy subjects and 5 Best Vitelliform macular dystrophy patients. Blue and red light stimuli (peak 485nm and 620nm, respectively) were presented at light intensities of 400 and 1000 cd/m2, respectively at 76 different points in a 16.2 degree VF. The PR of patients were compared with their findings on Humphrey's 24-2 perimetry, optical coherence tomography and the PR obtained from healthy subjects. Results: Patients demonstrated reduced percentage of pupillary contraction and slower maximal contraction velocity, more than two standard errors (SE) away from the mean of healthy subjects in response to red light in majority of VF locations. In response to blue light, the percentage of pupillary contraction was lower (by over two SE) compared with normal controls only in central locations. The latency of maximal contraction velocity was shorter in patients compared with healthy subjects in response to both colors. Conclusions: This study demonstrated the advantage of using MCP-based objective VF to assess central scotoma in macular degeneration. Our finding also suggests that chromatic perimetry may differentiate between PR mediated by cones and rods, and can specifically detect defects in macular cones. Different parameters of PR such as latency of maximal contraction velocity may shed light on the pathophysiology of different blinding diseases.
Yıldırım Karabağ, Revan; Günenç, Üzeyir; Aydın, Rukiye; Arıkan, Gül; Aslankara, Hüseyin
2018-01-01
Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a “mix and match” approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients’ dominant eyes and diffractive multifocal IOLs (Tecnis ZMA00) were implanted in their non-dominant eyes. Monocular and binocular uncorrected distance, intermediate and near visual acuity (logMAR), and contrast sensitivity levels were measured at 1, 3, and 6 months after cataract surgery. Defocus curves, reading speeds, patient satisfaction, spectacle dependence, and halo and glare symptoms were also evaluated at 6 months after the surgery. Postoperative quality of life was assessed with the Turkish version of National Eye Institute Visual Function Questionnaire-25. Results The study group comprised 8 females and 12 males with a mean age of 69.45±10.76 years (range, 31-86 years). The uncorrected distance and intermediate visual acuity levels were significantly better in the ReZoom-implanted eyes at postoperative 6 months (p=0.026 and p=0.037, respectively). There was no statistically significant difference in uncorrected near visual acuity (p>0.05). There was no statistically significant difference in contrast sensitivity, reading speed, halos, or glare between the groups (p<0.05). Mild glare/halo was reported by 40% of the subjects. The mean patient satisfaction was 95% and all patients were spectacle independent. Conclusion Mixing and matching multifocal IOLs in selected cataract patients provides excellent visual outcome, a high level of patient satisfaction, and spectacle independency. PMID:29576891
The number of seizures needed in the EMU.
Struck, Aaron F; Cole, Andrew J; Cash, Sydney S; Westover, M Brandon
2015-11-01
The purpose of this study was to develop a quantitative framework to estimate the likelihood of multifocal epilepsy based on the number of unifocal seizures observed in the epilepsy monitoring unit (EMU). Patient records from the EMU at Massachusetts General Hospital (MGH) from 2012 to 2014 were assessed for the presence of multifocal seizures as well the presence of multifocal interictal discharges and multifocal structural imaging abnormalities during the course of the EMU admission. Risk factors for multifocal seizures were assessed using sensitivity and specificity analysis. A Kaplan-Meier survival analysis was used to estimate the risk of multifocal epilepsy for a given number of consecutive seizures. To overcome the limits of the Kaplan-Meier analysis, a parametric survival function was fit to the EMU subjects with multifocal seizures and this was used to develop a Bayesian model to estimate the risk of multifocal seizures during an EMU admission. Multifocal interictal discharges were a significant predictor of multifocal seizures within an EMU admission with a p < 0.01, albeit with only modest sensitivity 0.74 and specificity 0.69. Multifocal potentially epileptogenic lesions on MRI were not a significant predictor p = 0.44. Kaplan-Meier analysis was limited by wide confidence intervals secondary to significant patient dropout and concern for informative censoring. The Bayesian framework provided estimates for the number of unifocal seizures needed to predict absence of multifocal seizures. To achieve 90% confidence for the absence of multifocal seizure, three seizures are needed when the pretest probability for multifocal epilepsy is 20%, seven seizures for a pretest probability of 50%, and nine seizures for a pretest probability of 80%. These results provide a framework to assist clinicians in determining the utility of trying to capture a specific number of seizures in EMU evaluations of candidates for epilepsy surgery. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.
Passive metamaterial-based acoustic holograms in ultrasound energy transfer systems
NASA Astrophysics Data System (ADS)
Bakhtiari-Nejad, Marjan; Elnahhas, Ahmed; Hajj, Muhammad R.; Shahab, Shima
2018-03-01
Contactless energy transfer (CET) is a technology that is particularly relevant in applications where wired electrical contact is dangerous or impractical. Furthermore, it would enhance the development, use, and reliability of low-power sensors in applications where changing batteries is not practical or may not be a viable option. One CET method that has recently attracted interest is the ultrasonic acoustic energy transfer, which is based on the reception of acoustic waves at ultrasonic frequencies by a piezoelectric receiver. Patterning and focusing the transmitted acoustic energy in space is one of the challenges for enhancing the power transmission and locally charging sensors or devices. We use a mathematically designed passive metamaterial-based acoustic hologram to selectively power an array of piezoelectric receivers using an unfocused transmitter. The acoustic hologram is employed to create a multifocal pressure pattern in the target plane where the receivers are located inside focal regions. We conduct multiphysics simulations in which a single transmitter is used to power multiple receivers with an arbitrary two-dimensional spatial pattern via wave controlling and manipulation, using the hologram. We show that the multi-focal pressure pattern created by the passive acoustic hologram will enhance the power transmission for most receivers.
Optical performance of multifocal soft contact lenses via a single-pass method.
Bakaraju, Ravi C; Ehrmann, Klaus; Falk, Darrin; Ho, Arthur; Papas, Eric
2012-08-01
A physical model eye capable of carrying soft contact lenses (CLs) was used as a platform to evaluate optical performance of several commercial multifocals (MFCLs) with high- and low-add powers and a single-vision control. Optical performance was evaluated at three pupil sizes, six target vergences, and five CL-correcting positions using a spatially filtered monochromatic (632.8 nm) light source. The various target vergences were achieved by using negative trial lenses. A photosensor in the retinal plane recorded the image point-spread that enabled the computation of visual Strehl ratios. The centration of CLs was monitored by an additional integrated en face camera. Hydration of the correcting lens was maintained using a humidity chamber and repeated instillations of rewetting saline drops. All the MFCLs reduced performance for distance but considerably improved performance along the range of distance to near target vergences, relative to the single-vision CL. Performance was dependent on add power, design, pupil, and centration of the correcting CLs. Proclear (D) design produced good performance for intermediate vision, whereas Proclear (N) design performed well at near vision (p < 0.05). AirOptix design exhibited good performance for distance and intermediate vision. PureVision design showed improved performance across the test vergences, but only for pupils ≥4 mm in diameter. Performance of Acuvue bifocal was comparable with other MFCLs, but only for pupils >4 mm in diameter. Acuvue Oasys bifocal produced performance comparable with single-vision CL for most vergences. Direct measurement of single-pass images at the retinal plane of a physical model eye used in conjunction with various MFCLs is demonstrated. This method may have utility in evaluating the relative effectiveness of commercial and prototype designs.
Schönbach, Etienne M; Chaikitmongkol, Voraporn; Annam, Rachel; McDonnell, Emma C; Wolfson, Yulia; Fletcher, Emily; Scholl, Hendrik P N
2017-01-01
We present the multifocal electroretinogram (mfERG) with a 7-hexagon array as an objective test of macular function that can be recorded in 14 s. We provide normal values and investigate its reproducibility and validity. Healthy participants underwent mfERG testing according to International Society for Clinical Electrophysiology of Vision (ISCEV) standards using the Espion Profile/D310 multifocal ERG system (Diagnosys, LLC, Lowell, MA, USA). One standard recording of a 61-hexagon array and 2 repeated recordings of a custom 7-hexagon array were obtained. A total of 13 subjects (mean age 46.9 years) were included. The median response densities were 12.5 nV/deg2 in the center and 5.2 nV/deg2 in the periphery. Intereye correlations were strong in both the center (ρCenter = 0.821; p < 0.0001) and the periphery (ρPeriphery = 0.862; p < 0.0001). Intraeye correlations were even stronger: ρCenter = 0.904 with p < 0.0001 and ρPeriphery = 0.955 with p < 0.0001. Bland-Altman plots demonstrated an acceptable retest mean difference in both the center and periphery, and narrow limits of agreement. We found strong correlations of the center (ρCenter = 0.826; p < 0.0001) and periphery (ρPeriphery = 0.848; p < 0.0001), with recordings obtained by the 61-hexagon method. The 7-hexagon mfERG provides reproducible results in agreement with results obtained according to the ISCEV standard. © 2017 S. Karger AG, Basel.
van Schaik, I N; Bouche, P; Illa, I; Léger, J-M; Van den Bergh, P; Cornblath, D R; Evers, E M A; Hadden, R D M; Hughes, R A C; Koski, C L; Nobile-Orazio, E; Pollard, J; Sommer, C; van Doorn, P A
2006-08-01
Several diagnostic criteria for multifocal motor neuropathy have been proposed in recent years and a beneficial effect of intravenous immunoglobulin (IVIg) and various other immunomodulatory drugs has been suggested in several trials and uncontrolled studies. The objectives were to prepare consensus guidelines on the definition, investigation and treatment of multifocal motor neuropathy. Disease experts and a patient representative considered references retrieved from MEDLINE and the Cochrane Library in July 2004 and prepared statements which were agreed in an iterative fashion. The Task Force agreed good practice points to define clinical and electrophysiological diagnostic criteria for multifocal motor neuropathy and investigations to be considered. The principal recommendations and good practice points were: (i) IVIg (2 g/kg given over 2-5 days) should be considered as the first line treatment (level A recommendation) when disability is sufficiently severe to warrant treatment. (ii) Corticosteroids are not recommended (good practice point). (iii) If initial treatment with IVIg is effective, repeated IVIg treatment should be considered (level C recommendation). The frequency of IVIg maintenance therapy should be guided by the individual response (good practice point). Typical treatment regimens are 1 g/kg every 2-4 weeks or 2 g/kg every 4-8 weeks (good practice point). (iv) If IVIg is not or not sufficiently effective then immunosuppressive treatment may be considered. Cyclophosphamide, ciclosporin, azathioprine, interferon beta1a, or rituximab are possible agents (good practice point). (v) Toxicity makes cyclophosphamide a less desirable option (good practice point).
Bansagi, Boglarka; Phan, Vietxuan; Baker, Mark R.; O'Sullivan, Julia; Jennings, Matthew J.; Whittaker, Roger G.; Müller, Juliane S.; Duff, Jennifer; Griffin, Helen; Miller, James A.L.; Gorman, Grainne S.; Lochmüller, Hanns; Chinnery, Patrick F.; Roos, Andreas; Swan, Laura E.
2018-01-01
Objective To describe a patient with a multifocal demyelinating motor neuropathy with onset in childhood and a mutation in phosphatase and tensin homolog (PTEN), a tumor suppressor gene associated with inherited tumor susceptibility conditions, macrocephaly, autism, ataxia, tremor, and epilepsy. Functional implications of this protein have been investigated in Parkinson and Alzheimer diseases. Methods We performed whole-exome sequencing in the patient's genomic DNA validated by Sanger sequencing. Immunoblotting, in vitro enzymatic assay, and label-free shotgun proteomic profiling were performed in the patient's fibroblasts. Results The predominant clinical presentation of the patient was a childhood onset, asymmetric progressive multifocal motor neuropathy. In addition, he presented with macrocephaly, autism spectrum disorder, and skin hamartomas, considered as clinical criteria for PTEN-related hamartoma tumor syndrome. Extensive tumor screening did not detect any malignancies. We detected a novel de novo heterozygous c.269T>C, p.(Phe90Ser) PTEN variant, which was absent in both parents. The pathogenicity of the variant is supported by altered expression of several PTEN-associated proteins involved in tumorigenesis. Moreover, fibroblasts showed a defect in catalytic activity of PTEN against the secondary substrate, phosphatidylinositol 3,4-trisphosphate. In support of our findings, focal hypermyelination leading to peripheral neuropathy has been reported in PTEN-deficient mice. Conclusion We describe a novel phenotype, PTEN-associated multifocal demyelinating motor neuropathy with a skin hamartoma syndrome. A similar mechanism may potentially underlie other forms of Charcot-Marie-Tooth disease with involvement of the phosphatidylinositol pathway. PMID:29720545
2018-04-01
Retroperitoneal sarcoma (RPS) is a rare disease accounting for 0.1%-0.2% of all malignancies. Management of RPS is complex and requires multidisciplinary, tailored treatment strategies at all stages, but especially in the context of metastatic or multifocal recurrent disease. Due to the rarity and heterogeneity of this family of diseases, the literature to guide management is limited. The Trans-Atlantic Retroperitoneal Sarcoma Working Group (TARPSWG) is an international collaboration of sarcoma experts from all disciplines convened in an effort to overcome these limitations. The TARPSWG has compiled the available evidence surrounding metastatic and multifocally recurrent RPS along with expert opinion in an iterative process to generate a consensus document regarding the complex management of this disease. The objective of this document is to guide sarcoma specialists from all disciplines in the diagnosis and treatment of multifocal recurrent or metastatic RPS. All aspects of patient assessment, diagnostic processes, local and systemic treatments, and palliation are reviewed in this document, and consensus recommendations provided accordingly. Recommendations were guided by available evidence, in conjunction with expert opinion where evidence was lacking. This consensus document combines the available literature regarding the management of multifocally recurrent or metastastic RPS with the practical expertise of high-volume sarcoma centers from multiple countries. It is designed as a tool for decision making in the complex multidisciplinary management of this condition and is expected to standardize management across centers, thereby ensuring that patients receive the highest quality care.
[Refraction after Implantation of Multifocal and Presbyopia-Correcting Intraocular Lenses].
Kretz, F T A; Linz, K; Mueller, M; Gerl, M; Koss, M J; Gerl, R H; Auffarth, G U
2015-08-01
Nowadays, further developments in the field of intraocular lenses offer a higher level of spectacle independence for our patients. As light gets scattered on different focal points a wider range of defocus is created. This greater defocus area makes it more difficult for us to determine the objective or subjective refraction. This contribution is concerned with the difficulties of measuring visual acuity in different intraocular lens designs and different measurement distances. Measuring refraction after implantation of a multifocal intraocular lens is a complex procedure and the experience of the examiner plays a crucial role. Retinoscopy, keratometry and the defocus curve are reliable methods for testing, while the auto refractometer, bichromatic testing and the cross-cylinder have limitations. Georg Thieme Verlag KG Stuttgart · New York.
Light distribution in diffractive multifocal optics and its optimization.
Portney, Valdemar
2011-11-01
To expand a geometrical model of diffraction efficiency and its interpretation to the multifocal optic and to introduce formulas for analysis of far and near light distribution and their application to multifocal intraocular lenses (IOLs) and to diffraction efficiency optimization. Medical device consulting firm, Newport Coast, California, USA. Experimental study. Application of a geometrical model to the kinoform (single focus diffractive optical element) was expanded to a multifocal optic to produce analytical definitions of light split between far and near images and light loss to other diffraction orders. The geometrical model gave a simple interpretation of light split in a diffractive multifocal IOL. An analytical definition of light split between far, near, and light loss was introduced as curve fitting formulas. Several examples of application to common multifocal diffractive IOLs were developed; for example, to light-split change with wavelength. The analytical definition of diffraction efficiency may assist in optimization of multifocal diffractive optics that minimize light loss. Formulas for analysis of light split between different foci of multifocal diffractive IOLs are useful in interpreting diffraction efficiency dependence on physical characteristics, such as blaze heights of the diffractive grooves and wavelength of light, as well as for optimizing multifocal diffractive optics. Disclosure is found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Snapshot 3D tracking of insulin granules in live cells
NASA Astrophysics Data System (ADS)
Wang, Xiaolei; Huang, Xiang; Gdor, Itay; Daddysman, Matthew; Yi, Hannah; Selewa, Alan; Haunold, Theresa; Hereld, Mark; Scherer, Norbert F.
2018-02-01
Rapid and accurate volumetric imaging remains a challenge, yet has the potential to enhance understanding of cell function. We developed and used a multifocal microscope (MFM) for 3D snapshot imaging to allow 3D tracking of insulin granules labeled with mCherry in MIN6 cells. MFM employs a special diffractive optical element (DOE) to simultaneously image multiple focal planes. This simultaneous acquisition of information determines the 3D location of single objects at a speed only limited by the array detector's frame rate. We validated the accuracy of MFM imaging/tracking with fluorescence beads; the 3D positions and trajectories of single fluorescence beads can be determined accurately over a wide range of spatial and temporal scales. The 3D positions and trajectories of single insulin granules in a 3.2um deep volume were determined with imaging processing that combines 3D decovolution, shift correction, and finally tracking using the Imaris software package. We find that the motion of the granules is superdiffusive, but less so in 3D than 2D for cells grown on coverslip surfaces, suggesting an anisotropy in the cytoskeleton (e.g. microtubules and action).
Rasp, Max; Bachernegg, Alexander; Seyeddain, Orang; Ruckhofer, Josef; Emesz, Martin; Stoiber, Josef; Grabner, Günther; Dexl, Alois K
2012-11-01
To compare changes in reading performance parameters after implantation of 4 multifocal intraocular lens (IOL) models and a monofocal IOL. Department of Ophthalmology, Paracelsus Medical University, Salzburg, Austria. Prospective randomized controlled clinical trial. Patients with bilateral cataract without additional ocular pathology were scheduled for bilateral implantation of Acri.Smart 48S monofocal, Acrysof Restor SN6AD3 apodized multifocal, AT LISA 366D diffractive multifocal, Tecnis ZMA00 diffractive multifocal, or Rezoom refractive multifocal IOLs. Bilateral corrected and uncorrected reading acuity, reading distance, mean and maximum reading speeds, and smallest log-scaled print size of a Radner reading chart were evaluated under bright lighting conditions (500 lux) using the Salzburg Reading Desk. Pupil size was not measured throughout the trial. The minimum follow-up was 12 months. The diffractive multifocal groups had significantly better uncorrected reading acuity and uncorrected smallest print size than the monofocal and refractive multifocal groups 1, 6, and 12 months postoperatively. The diffractive IOL groups had comparable uncorrected reading distance of approximately 32 cm, which was larger in the monofocal group (38.9 ± 8.4 cm) and refractive multifocal group (37.1 ± 7.3 cm) at the last visit. Patients with diffractive IOLs could read print sizes of approximately 0.74 to 0.87 mm, which was much better than in the monofocal and refractive multifocal groups. The diffractive AT LISA IOL provided the best reading speed values (mean and maximum, corrected and uncorrected). Multifocal IOLs with a diffractive component provided good reading performance that was significantly better than that obtained with a refractive multifocal or monofocal IOL. Drs. Grabner and Dexl were patent owners of the Salzburg Reading Desk technology (now owned by SRD-Vision, LLC). No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Aalders, K C; Kuijer, A; Straver, M E; Slaets, L; Litiere, S; Viale, G; Van't Veer, L J; Glas, A M; Delorenzi, M; van Dalen, T; Tryfonidis, K; Piccart, M J; Cardoso, F; Rutgers, E J
2017-07-01
In multifocal breast cancer, guidelines recommend basing adjuvant systemic treatment decisions on characteristics of the largest lesion, disregarding multifocality as an independent prognosticator. We assessed the association between multifocal disease and both the 70-gene signature (70-GS), and distant metastasis-free survival (DMFS) in clinical low-risk breast cancer patients enrolled in the European Organisation for Research and Treatment of Cancer 10041/BIG 03-04 Microarray In Node-negative and 1 to 3 positive lymph node Disease may Avoid ChemoTherapy (MINDACT) trial. The analysed population consisted of enrolled patients in the MINDACT trial with clinical low-risk disease, defined by a modified Adjuvant! Online cut-off for the 10-year risk of recurrent disease or death. Eligibility criteria of MINDACT dictate that patients with multifocal disease could be included if the different lesions had similar pathological characteristics. The presence of multifocal disease was deducted from the case report form (CRF)-question for sum of diameter for all invasive tumour foci. Clinicopathological characteristics and gene expression of patients with unifocal and multifocal (largest lesion) disease were compared. Subsequently, the association between multifocal disease and the 70-GS was evaluated as well as the association between multifocality and 5-year DMFS. The study included 3090 clinical low-risk patients with unifocal and 238 patients with multifocal disease. Apart from a higher prevalence of lobular tumours (21.8% versus 10.8%, by local pathology), we did not observe differences in baseline characteristics between multifocal and unifocal tumours. Patients with multifocal tumours were more likely to be at high genomic risk as compared to patients with unifocal tumours (22.7% versus 17.3%, odds ratio [OR] 1.45, 95% confidence interval [CI] 1.02-2.07, P = 0.038). We did not find a significant association between tumour focality and DMFS (97.1% for unifocal versus 96.9% for multifocal, hazard ratio [HR] = 1.55, 95% CI 0.68-3.46, P = 0.172), nor a signal for a potential interaction between the prognostic effect of the 70-GS and focality of the tumour regarding DMFS. In the group of clinical low-risk MINDACT patients, multifocal tumours were more likely to have a high-risk 70-GS profile compared to unifocal tumours. We did not observe a significant interaction between multifocality and the 70-GS with respect to survival without distant metastasis in these patients. Copyright © 2017 Elsevier Ltd. All rights reserved.
MULTIMODAL IMAGING OF SYPHILITIC MULTIFOCAL RETINITIS.
Curi, Andre L; Sarraf, David; Cunningham, Emmett T
2015-01-01
To describe multimodal imaging of syphilitic multifocal retinitis. Observational case series. Two patients developed multifocal retinitis after treatment of unrecognized syphilitic uveitis with systemic corticosteroids in the absence of appropriate antibiotic therapy. Multimodal imaging localized the foci of retinitis within the retina in contrast to superficial retinal precipitates that accumulate on the surface of the retina in eyes with untreated syphilitic uveitis. Although the retinitis resolved after treatment with systemic penicillin in both cases, vision remained poor in the patient with multifocal retinitis involving the macula. Treatment of unrecognized syphilitic uveitis with corticosteroids in the absence of antitreponemal treatment can lead to the development of multifocal retinitis. Multimodal imaging, and optical coherence tomography in particular, can be used to distinguish multifocal retinitis from superficial retinal precipitates or accumulations.
Zhu, Yifan; Hu, Jie; Fan, Xudong; Yang, Jing; Liang, Bin; Zhu, Xuefeng; Cheng, Jianchun
2018-04-24
The fine manipulation of sound fields is critical in acoustics yet is restricted by the coupled amplitude and phase modulations in existing wave-steering metamaterials. Commonly, unavoidable losses make it difficult to control coupling, thereby limiting device performance. Here we show the possibility of tailoring the loss in metamaterials to realize fine control of sound in three-dimensional (3D) space. Quantitative studies on the parameter dependence of reflection amplitude and phase identify quasi-decoupled points in the structural parameter space, allowing arbitrary amplitude-phase combinations for reflected sound. We further demonstrate the significance of our approach for sound manipulation by producing self-bending beams, multifocal focusing, and a single-plane two-dimensional hologram, as well as a multi-plane 3D hologram with quality better than the previous phase-controlled approach. Our work provides a route for harnessing sound via engineering the loss, enabling promising device applications in acoustics and related fields.
Alvarez, George A; Gill, Jonathan; Cavanagh, Patrick
2012-01-01
Previous studies have shown independent attentional selection of targets in the left and right visual hemifields during attentional tracking (Alvarez & Cavanagh, 2005) but not during a visual search (Luck, Hillyard, Mangun, & Gazzaniga, 1989). Here we tested whether multifocal spatial attention is the critical process that operates independently in the two hemifields. It is explicitly required in tracking (attend to a subset of object locations, suppress the others) but not in the standard visual search task (where all items are potential targets). We used a modified visual search task in which observers searched for a target within a subset of display items, where the subset was selected based on location (Experiments 1 and 3A) or based on a salient feature difference (Experiments 2 and 3B). The results show hemifield independence in this subset visual search task with location-based selection but not with feature-based selection; this effect cannot be explained by general difficulty (Experiment 4). Combined, these findings suggest that hemifield independence is a signature of multifocal spatial attention and highlight the need for cognitive and neural theories of attention to account for anatomical constraints on selection mechanisms. PMID:22637710
Three-dimensional vectorial multifocal arrays created by pseudo-period encoding
NASA Astrophysics Data System (ADS)
Zeng, Tingting; Chang, Chenliang; Chen, Zhaozhong; Wang, Hui-Tian; Ding, Jianping
2018-06-01
Multifocal arrays have been attracting considerable attention recently owing to their potential applications in parallel optical tweezers, parallel single-molecule orientation determination, parallel recording and multifocal multiphoton microscopy. However, the generation of vectorial multifocal arrays with a tailorable structure and polarization state remains a great challenge, and reports on multifocal arrays have hitherto been restricted either to scalar focal spots without polarization versatility or to regular arrays with fixed spacing. In this work, we propose a specific pseudo-period encoding technique to create three-dimensional (3D) vectorial multifocal arrays with the ability to manipulate the position, polarization state and intensity of each focal spot. We experimentally validated the flexibility of our approach in the generation of 3D vectorial multiple spots with polarization multiplicity and position tunability.
A rare case of a medullary, multifocal lesion in the distal radius
Aktas, Birol; Ozturan, Burak; Kilic, Bulent; Ozkan, Korhan
2017-01-01
In multifocal findings, the possibility of multifocal osteoid osteomas should be considered and this case helps us to be attentive for the unusual radiographical presentation of osteoid osteoma. PMID:28748099
Glatz, Andreas; Valdés Hernández, Maria C.; Kiker, Alexander J.; Bastin, Mark E.; Deary, Ian J.; Wardlaw, Joanna M.
2013-01-01
Multifocal T2*-weighted (T2*w) hypointensities in the basal ganglia, which are believed to arise predominantly from mineralized small vessels and perivascular spaces, have been proposed as a biomarker for cerebral small vessel disease. This study provides baseline data on their appearance on conventional structural MRI for improving and automating current manual segmentation methods. Using a published thresholding method, multifocal T2*w hypointensities were manually segmented from whole brain T2*w volumes acquired from 98 community-dwelling subjects in their early 70s. Connected component analysis was used to derive the average T2*w hypointensity count and load per basal ganglia nucleus, as well as the morphology of their connected components, while nonlinear spatial probability mapping yielded their spatial distribution. T1-weighted (T1w), T2-weighted (T2w) and T2*w intensity distributions of basal ganglia T2*w hypointensities and their appearance on T1w and T2w MRI were investigated to gain further insights into the underlying tissue composition. In 75/98 subjects, on average, 3 T2*w hypointensities with a median total volume per intracranial volume of 50.3 ppm were located in and around the globus pallidus. Individual hypointensities appeared smooth and spherical with a median volume of 12 mm3 and median in-plane area of 4 mm2. Spatial probability maps suggested an association between T2*w hypointensities and the point of entry of lenticulostriate arterioles into the brain parenchyma. T1w and T2w and especially the T2*w intensity distributions of these hypointensities, which were negatively skewed, were generally not normally distributed indicating an underlying inhomogeneous tissue structure. Globus pallidus T2*w hypointensities tended to appear hypo- and isointense on T1w and T2w MRI, whereas those from other structures appeared iso- and hypointense. This pattern could be explained by an increased mineralization of the globus pallidus. In conclusion, the characteristic spatial distribution and appearance of multifocal basal ganglia T2*w hypointensities in our elderly cohort on structural MRI appear to support the suggested association with mineralized proximal lenticulostriate arterioles and perivascular spaces. PMID:23769704
Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José
2012-02-01
To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.
Multifocal interferometric synthetic aperture microscopy
Xu, Yang; Chng, Xiong Kai Benjamin; Adie, Steven G.; Boppart, Stephen A.; Scott Carney, P.
2014-01-01
There is an inherent trade-off between transverse resolution and depth of field (DOF) in optical coherence tomography (OCT) which becomes a limiting factor for certain applications. Multifocal OCT and interferometric synthetic aperture microscopy (ISAM) each provide a distinct solution to the trade-off through modification to the experiment or via post-processing, respectively. In this paper, we have solved the inverse problem of multifocal OCT and present a general algorithm for combining multiple ISAM datasets. Multifocal ISAM (MISAM) uses a regularized combination of the resampled datasets to bring advantages of both multifocal OCT and ISAM to achieve optimal transverse resolution, extended effective DOF and improved signal-to-noise ratio. We present theory, simulation and experimental results. PMID:24977909
Doppler, Kathrin; Appeltshauser, Luise; Krämer, Heidrun H; Ng, Judy King Man; Meinl, Edgar; Villmann, Carmen; Brophy, Peter; Dib-Hajj, Sulayman D; Waxman, Stephen G; Weishaupt, Andreas; Sommer, Claudia
2015-01-01
Multifocal motor neuropathy is an immune mediated disease presenting with multifocal muscle weakness and conduction block. IgM auto-antibodies against the ganglioside GM1 are detectable in about 50% of the patients. Auto-antibodies against the paranodal proteins contactin-1 and neurofascin-155 and the nodal protein neurofascin-186 have been detected in subgroups of patients with chronic inflammatory demyelinating polyneuropathy. Recently, auto-antibodies against neurofascin-186 and gliomedin were described in more than 60% of patients with multifocal motor neuropathy. In the current study, we aimed to validate this finding, using a combination of different assays for auto-antibody detection. In addition we intended to detect further auto-antibodies against paranodal proteins, specifically contactin-1 and neurofascin-155 in multifocal motor neuropathy patients' sera. We analyzed sera of 33 patients with well-characterized multifocal motor neuropathy for IgM or IgG anti-contactin-1, anti-neurofascin-155 or -186 antibodies using enzyme-linked immunosorbent assay, binding assays with transfected human embryonic kidney 293 cells and murine teased fibers. We did not detect any IgM or IgG auto-antibodies against contactin-1, neurofascin-155 or -186 in any of our multifocal motor neuropathy patients. We conclude that auto-antibodies against contactin-1, neurofascin-155 and -186 do not play a relevant role in the pathogenesis in this cohort with multifocal motor neuropathy.
Dyck, Peter J.; Taylor, Bruce V.; Davies, Jenny L.; Mauermann, Michelle L.; Litchy, William J.; Klein, Christopher J.; Dyck, P. James B.
2015-01-01
Background Intravenous immunoglobulin [IVIg], plasma exchange [PE], and corticosteroids are efficacious treatment in chronic inflammatory demyelinating polyneuropathy [CIDP]. IVIg is effective in multifocal motor neuropathy [MMN]. Objective and Methods Results and Conclusions NIS, NIS-weakness, sum scores of raw amplitudes of motor fiber (CMAPs) amplitudes, and Dyck/Rankin score provided reliable measures to detect and scale abnormality and reflect change; they are therefore ideal for office management of response-basedimmunotherapy (R-IRx) of CIDP. Using efficacious R-IRx, a large early and late therapeutic response (≥ one-fourth were in remission or had recovered) was demonstrated in CIDP. In MMN only an early improvement with late non-significant worsening was observed. The difference in immunotherapy response supports a fundamental difference between CIDP (immune attack on Schwann cells and myelin) and MMN (attack on nodes of Ranvier and axons). PMID:25976871
Renz, Erik; Hackney, Madeleine; Hall, Courtney
2016-01-01
Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.
Comparison of two laboratory-based systems for evaluation of halos in intraocular lenses
Alexander, Elsinore; Wei, Xin; Lee, Shinwook
2018-01-01
Purpose Multifocal intraocular lenses (IOLs) can be associated with unwanted visual phenomena, including halos. Predicting potential for halos is desirable when designing new multifocal IOLs. Halo images from 6 IOL models were compared using the Optikos modulation transfer function bench system and a new high dynamic range (HDR) system. Materials and methods One monofocal, 1 extended depth of focus, and 4 multifocal IOLs were evaluated. An off-the-shelf optical bench was used to simulate a distant (>50 m) car headlight and record images. A custom HDR system was constructed using an imaging photometer to simulate headlight images and to measure quantitative halo luminance data. A metric was developed to characterize halo luminance properties. Clinical relevance was investigated by correlating halo measurements to visual outcomes questionnaire data. Results The Optikos system produced halo images useful for visual comparisons; however, measurements were relative and not quantitative. The HDR halo system provided objective and quantitative measurements used to create a metric from the area under the curve (AUC) of the logarithmic normalized halo profile. This proposed metric differentiated between IOL models, and linear regression analysis found strong correlations between AUC and subjective clinical ratings of halos. Conclusion The HDR system produced quantitative, preclinical metrics that correlated to patients’ subjective perception of halos. PMID:29503526
Nuijts, Rudy M M A; Jonker, Soraya M R; Kaufer, Robert A; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas
2016-02-01
To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8 investigative sites. Prospective randomized parallel-group patient-masked 2-arm study. This study comprised adults requiring bilateral cataract extraction followed by multifocal IOL implantation. The primary endpoint was corrected intermediate visual acuity (CIVA) at 60 cm, and the secondary endpoint was corrected near visual acuity (CNVA) at 40 cm. Both endpoints were measured 3 months after implantation with a noninferiority margin of Δ = 0.1 logMAR. In total, 103 patients completed the study (53 bilateral, 50 contralateral). At 3 months, the mean CIVA at 60 cm was 0.13 logMAR and 0.10 logMAR in the bilateral group and contralateral group, respectively (difference 0.04 logMAR), achieving noninferiority. Noninferiority was not attained for CNVA at 40 cm; mean values at 3 months for bilateral and contralateral implantation were 0.26 logMAR and 0.11 logMAR, respectively (difference 0.15 logMAR). Binocular defocus curves suggested similar performance in distance vision between the 2 groups. Treatment-emergent ocular adverse events rates were similar between the groups. Bilateral implantation of the +2.5 D multifocal IOL resulted in similar distance as contralateral implantation of the +2.5 D multifocal IOL and +3.0 D multifocal IOL for intermediate vision (60 cm), while noninferiority was not achieved for near distances (40 cm). Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Multifocal lymphangioendotheliomatosis with devastating intracranial hemorrhage.
Huang, Christina; Rizk, Elias; Iantosca, Mark; Zaenglein, Andrea L; Helm, Klaus F; Choudhary, Arabinda K; Dias, Mark S
2013-11-01
An in utero female was found to have a small hemorrhage at the foramen of Monro, hydrocephalus, and what was originally interpreted as a Dandy-Walker variant. At birth she had macrocephaly and numerous cutaneous, multifocal, red-pink blanchable macules. Postnatal MRI demonstrated a hemorrhagic soft-tissue mass involving the upper brainstem, thalamus, and basal ganglia most consistent with in utero complex multifocal intracranial hemorrhage. The skin lesions were thought to be consistent with multifocal lymphangioendotheliomatosis with thrombocytopenia (MLT). The size and location of the hemorrhage precluded operative intervention, although the hydrocephalus was treated with a ventricular shunt. The child continues to have severe developmental delays. Multifocal lymphangioendotheliomatosis with thrombocytopenia is a multifocal vascular disorder most commonly involving the skin and gastrointestinal tract. Intracranial hemorrhages are rare in this context. This case is the third reported instance of MLT with associated intracranial hemorrhage and the only case described in the neurosurgical literature. The authors review the presenting features and pathophysiology of this condition.
Horn, Folkert K; Selle, Franziska; Hohberger, Bettina; Kremers, Jan
2016-02-01
To investigate whether a conventional, monitor-based multifocal visual evoked potential (mfVEP) system can be used to record steady-state mfVEP (ssmfVEP) in healthy subjects and to study the effects of temporal frequency, electrode configuration and alpha waves. Multifocal pattern reversal VEP measurements were performed at 58 dartboard fields using VEP recording equipment. The responses were measured using m-sequences with four pattern reversals per m-step. Temporal frequencies were varied between 6 and 15 Hz. Recordings were obtained from nine normal subjects with a cross-shaped, four-electrode device (two additional channels were derived). Spectral analyses were performed on the responses at all locations. The signal to noise ratio (SNR) was computed for each response using the signal amplitude at the reversal frequency and the noise at the neighbouring frequencies. Most responses in the ssmfVEP were significantly above noise. The SNR was largest for an 8.6-Hz reversal frequency. The individual alpha electroencephalogram (EEG) did not strongly influence the results. The percentage of the records in which each of the 6 channels had the largest SNR was between 10.0 and 25.2 %. Our results in normal subjects indicate that reliable mfVEP responses can be achieved by steady-state stimulation using a conventional dartboard stimulator and multi-channel electrode device. The ssmfVEP may be useful for objective visual field assessment as spectrum analysis can be used for automated evaluation of responses. The optimal reversal frequency is 8.6 Hz. Alpha waves have only a minor influence on the analysis. Future studies must include comparisons with conventional mfVEP and psychophysical visual field tests.
Savini, Giacomo; Hoffer, Kenneth J; Lombardo, Marco; Serrao, Sebastiano; Schiano-Lomoriello, Domenico; Ducoli, Pietro
2016-01-01
To calculate the near focal distance of different multifocal intraocular lenses (IOLs) as a function of the 2 parameters that are measured before cataract surgery; that is, axial length (AL) and refractive corneal power (keratometry [K]). GB Bietti Foundation IRCCS, Rome, Italy. Noninterventional theoretical study. The IOL power for emmetropia was first calculated in an eye model with the AL ranging from 20 to 30 mm and K from 38 to 48 diopters (D). Then, the predicted myopic refraction for any given IOL add power (from +1.5 to +4.0 D) was calculated, and from this value the near focal distance was obtained. Calculations were also performed for the average eye (K = 43.81 D; AL = 23.65 mm). The near focal distance increased with increasing values of K and AL for each near power add. The near focal distance ranged between 53 cm and 72 cm (21 inches and 28 inches) for a multifocal IOL with +2.50 D, between 44 cm and 60 cm (17 inches and 24 inches) for a multifocal IOL with +3.00 D add, and between 33 cm and 44 cm (13 inches and 18 inches) for a multifocal IOL with +4.00 D add. In the average eye, the near focal distance ranges between 36 cm (near add power = 4.00 D) and 99 cm (near add power = 1.5 D). Longer eyes with steeper corneas showed the longest near focal distance and could experience more difficulties in focusing near objects after surgery. The opposite was true for short hyperopic eyes. Dr. Hoffer receives licensing fees for the commercial use of the registered trademark Hoffer from all biometry manufacturers using the Hoffer Q formula to ensure that it is programmed correctly and book royalties from Slack, Inc., for the textbook IOL Power. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Foley, Nicholas C.; Grossberg, Stephen; Mingolla, Ennio
2015-01-01
How are spatial and object attention coordinated to achieve rapid object learning and recognition during eye movement search? How do prefrontal priming and parietal spatial mechanisms interact to determine the reaction time costs of intra-object attention shifts, inter-object attention shifts, and shifts between visible objects and covertly cued locations? What factors underlie individual differences in the timing and frequency of such attentional shifts? How do transient and sustained spatial attentional mechanisms work and interact? How can volition, mediated via the basal ganglia, influence the span of spatial attention? A neural model is developed of how spatial attention in the where cortical stream coordinates view-invariant object category learning in the what cortical stream under free viewing conditions. The model simulates psychological data about the dynamics of covert attention priming and switching requiring multifocal attention without eye movements. The model predicts how “attentional shrouds” are formed when surface representations in cortical area V4 resonate with spatial attention in posterior parietal cortex (PPC) and prefrontal cortex (PFC), while shrouds compete among themselves for dominance. Winning shrouds support invariant object category learning, and active surface-shroud resonances support conscious surface perception and recognition. Attentive competition between multiple objects and cues simulates reaction-time data from the two-object cueing paradigm. The relative strength of sustained surface-driven and fast-transient motion-driven spatial attention controls individual differences in reaction time for invalid cues. Competition between surface-driven attentional shrouds controls individual differences in detection rate of peripheral targets in useful-field-of-view tasks. The model proposes how the strength of competition can be mediated, though learning or momentary changes in volition, by the basal ganglia. A new explanation of crowding shows how the cortical magnification factor, among other variables, can cause multiple object surfaces to share a single surface-shroud resonance, thereby preventing recognition of the individual objects. PMID:22425615
Foley, Nicholas C; Grossberg, Stephen; Mingolla, Ennio
2012-08-01
How are spatial and object attention coordinated to achieve rapid object learning and recognition during eye movement search? How do prefrontal priming and parietal spatial mechanisms interact to determine the reaction time costs of intra-object attention shifts, inter-object attention shifts, and shifts between visible objects and covertly cued locations? What factors underlie individual differences in the timing and frequency of such attentional shifts? How do transient and sustained spatial attentional mechanisms work and interact? How can volition, mediated via the basal ganglia, influence the span of spatial attention? A neural model is developed of how spatial attention in the where cortical stream coordinates view-invariant object category learning in the what cortical stream under free viewing conditions. The model simulates psychological data about the dynamics of covert attention priming and switching requiring multifocal attention without eye movements. The model predicts how "attentional shrouds" are formed when surface representations in cortical area V4 resonate with spatial attention in posterior parietal cortex (PPC) and prefrontal cortex (PFC), while shrouds compete among themselves for dominance. Winning shrouds support invariant object category learning, and active surface-shroud resonances support conscious surface perception and recognition. Attentive competition between multiple objects and cues simulates reaction-time data from the two-object cueing paradigm. The relative strength of sustained surface-driven and fast-transient motion-driven spatial attention controls individual differences in reaction time for invalid cues. Competition between surface-driven attentional shrouds controls individual differences in detection rate of peripheral targets in useful-field-of-view tasks. The model proposes how the strength of competition can be mediated, though learning or momentary changes in volition, by the basal ganglia. A new explanation of crowding shows how the cortical magnification factor, among other variables, can cause multiple object surfaces to share a single surface-shroud resonance, thereby preventing recognition of the individual objects. Copyright © 2012 Elsevier Inc. All rights reserved.
Multifocal systemic tuberculosis: the many faces of an old nemesis.
Al-Tawfiq, Jaffar A
2007-04-01
Tuberculosis continues to be a major health problem, where an estimated 7-8 million new cases are diagnosed each year. Multifocal tuberculosis is characterized by the presence of large multifocal tuberculous areas in the same or different organs. Difficulty in diagnosis of multifocal tuberculosis and consideration of other diseases may lead to a delay in diagnosing this entity. Here the clinical features and characteristics of three patients with multifocal systemic tuberculosis are described. During the period of 1999-2005, a total of 128 confirmed cases of tuberculosis were identified. Three (2.3%) patients had multifocal systemic tuberculosis. The first case had involvement of the lung, psoas muscle, and the vertebral bodies. The second patient had multiple brain lesions with mediastinal and retroperitoneal lymphadenopathy. The third patient had multiple brain lesions, lymphadenopathy, and colonic lesions initially mimicking a metastatic disease. Mycobacterium tuberculosis was grown from pleural fluid in one patient and from lymph node biopsies in another patient. The third patient had histopathologic evidence of tuberculosis. All patients received standard anti-tuberculous treatment, resulting in a full recovery in two patients, while the third patient had residual weakness. Multifocal systemic tuberculosis may pose a diagnostic challenge and may occur in immunocompetent hosts, in whom this entity generally has a good outcome.
Qureshi, Sajid S; Bhagat, Monica; Kembhavi, Seema; Vora, Tushar; Ramadwar, Mukta; Talole, Sanjay
2015-06-01
To determine the outcomes of resection of satellite lesions in PRE-treatment Tumor EXTension (PRETEXT) II and III multifocal hepatoblastoma irrespective of their disappearance after chemotherapy. To compare the overall outcomes of multifocal and unifocal hepatoblastoma. Fourteen patients with PRETEXT II (n = 7) and III (n = 7) multifocal hepatoblastoma treated between April 2006 and July 2014 were analyzed and their outcomes were compared with PRETEXT II and III unifocal hepatoblastoma treated in the similar period. Satellite lesion or the affected segments with disappeared satellite lesions were resected in 11 patients. Amongst them, all relapses were distant except one in the liver. In contrast, two of three patients developed liver relapse when the affected segments were not resected. None of the patients receiving intensive chemotherapy based on SIOPEL-3 guidelines developed a relapse. The 3-year event-free and overall survival were 38.6 and 42.9% in multifocal hepatoblastoma and 86.4 and 92.4% in unifocal hepatoblastoma (p = 0.001). Multifocality (p = 0.002) and AFP >10,000 after induction chemotherapy significantly affected event-free survival (p = 0.01). Multifocal hepatoblastoma is associated with poor outcomes as compared to unifocal hepatoblastoma. These preliminary observations of relapse and the role of chemotherapy intensification deserve further study in a multicenter controlled trial setting.
Trout, Andrew T; Batie, Matthew R; Gupta, Anita; Sheridan, Rachel M; Tiao, Gregory M; Towbin, Alexander J
2017-11-01
Radiogenomics promises to identify tumour imaging features indicative of genomic or proteomic aberrations that can be therapeutically targeted allowing precision personalised therapy. An accurate radiological-pathological correlation is critical to the process of radiogenomic characterisation of tumours. An accurate correlation, however, is difficult to achieve with current pathological sectioning techniques which result in sectioning in non-standard planes. The purpose of this work is to present a technique to standardise hepatic sectioning to facilitateradiological-pathological correlation. We describe a process in which three-dimensional (3D)-printed specimen boxes based on preoperative cross-sectional imaging (CT and MRI) can be used to facilitate pathological sectioning in standard planes immediately on hepatic resection enabling improved tumour mapping. We have applied this process in 13 patients undergoing hepatectomy and have observed close correlation between imaging and gross pathology in patients with both unifocal and multifocal tumours. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Re-evaluating the concept of "dominant/index tumor nodule" in multifocal prostate cancer.
Huang, Cheng Cheng; Deng, Fang-Ming; Kong, Max X; Ren, Qinhu; Melamed, Jonathan; Zhou, Ming
2014-05-01
Prostate cancer (PCa) often presents as a multifocal disease with heterogeneity in Gleason score (GS) and genetic alterations. Dominant/index tumor nodule (DN), the largest nodule in a multifocal disease, is presumed to harbor the most aggressive biological behavior and therefore dictate the overall clinical behavior of PCa. In this study, we examined the pathological features of DN and re-evaluated the validity of the "DN" concept in multifocal PCa. A total of 201 consecutive radical prostatectomy specimens were totally submitted and examined. All independent cancer foci were recorded with prognostically important pathological parameters. Unifocal and multifocal disease was present in 25 (12.4 %) and 176 (87.6 %) cases, respectively. In 20 (11.3 %) multifocal cases, the highest GS, the largest tumor volume (TV), and extraprostatic extension (EPE) did not concur in the same tumor nodules. Non-DNs had a higher GS and EPE in 13 cases each and had both the highest GS and EPE in 5 cases. In the majority of multifocal prostate cancer (88.7 %), DNs have the highest GS and EPE. In these cases, DN is still a valid concept and can be used for assigning overall GS and procuring tissue for research. However, in a significant number of cases (11.3 %), the largest TV, the highest GS, and EPE did not concur in the same tumor nodules. In these cases, pathologists should de-emphasize the concept of DN. Instead, they should place the emphasis on the multifocal nature of the disease and document the pathological features of all independent tumor foci that have the largest TV, the highest GS, and EPE.
Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens.
Hayashi, Ken; Manabe, Shin-Ichi; Yoshida, Motoaki; Hayashi, Hideyuki
2010-08-01
To examine the effect of astigmatism on visual acuity at various distances in eyes with a diffractive multifocal intraocular lens (IOL). Hayashi Eye Hospital, Fukuoka, Japan. In this study, eyes had implantation of a diffractive multifocal IOL with a +3.00 diopter (D) addition (add) (AcrySof ReSTOR SN6AD1), a diffractive multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), or a monofocal IOL (AcrySof SN60WF). Astigmatism was simulated by adding cylindrical lenses of various diopters (0.00, 0.50, 1.00, 1.50, 2.00), after which distance-corrected acuity was measured at various distances. At most distances, the mean visual acuity in the multifocal IOL groups decreased in proportion to the added astigmatism. With astigmatism of 0.00 D and 0.50 D, distance-corrected near visual acuity (DCNVA) in the +4.00 D group and distance-corrected intermediate visual acuity (DCIVA) and DCNVA in the +3.00 D group were significantly better than in the monofocal group; the corrected distance visual acuity (CDVA) was similar. The DCNVA with astigmatism of 1.00 D was better in 2 multifocal groups; however, with astigmatism of 1.50 D and 2.00 D, the CDVA and DCIVA at 0.5m in the multifocal groups were significantly worse than in the monofocal group, although the DCNVA was similar. With astigmatism of 1.00 D or greater, the mean CDVA and DCNVA in the multifocal groups reached useful levels (20/40). The presence of astigmatism in eyes with a diffractive multifocal IOL compromised all distance visual acuities, suggesting the need to correct astigmatism of greater than 1.00 D. No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Multifocal versus monofocal intraocular lenses after cataract extraction.
de Silva, Samantha R; Evans, Jennifer R; Kirthi, Varo; Ziaei, Mohammed; Leyland, Martin
2016-12-12
Good unaided distance visual acuity (VA) is now a realistic expectation following cataract surgery and intraocular lens (IOL) implantation. Near vision, however, still requires additional refractive power, usually in the form of reading glasses. Multiple optic (multifocal) IOLs are available which claim to allow good vision at a range of distances. It is unclear whether this benefit outweighs the optical compromises inherent in multifocal IOLs. To assess the visual effects of multifocal IOLs in comparison with the current standard treatment of monofocal lens implantation. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2016), Embase (January 1980 to June 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 June 2016. All randomised controlled trials comparing a multifocal IOL of any type with a monofocal IOL as control were included. Both unilateral and bilateral implantation trials were included. We also considered trials comparing multifocal IOLs with "monovision" whereby one eye is corrected for distance vision and one eye corrected for near vision. We used standard methodological procedures expected by Cochrane. We assessed the 'certainty' of the evidence using GRADE. We found 20 eligible trials that enrolled 2230 people with data available on 2061 people (3194 eyes). These trials were conducted in Europe (13), China (three), USA (one), Middle East (one), India (one) and one multicentre study in Europe and the USA. Most of these trials compared multifocal with monofocal lenses; two trials compared multifocal lenses with monovision. There was considerable variety in the make and model of lenses implanted. Overall we considered the trials at risk of performance and detection bias because it was difficult to mask participants and outcome assessors. It was also difficult to assess the role of reporting bias.There was moderate-certainty evidence that the distance acuity achieved with multifocal lenses was not different to that achieved with monofocal lenses (unaided VA worse than 6/6: pooled RR 0.96, 95% confidence interval (CI) 0.89 to 1.03; eyes = 682; studies = 8). People receiving multifocal lenses may achieve better near vision (RR for unaided near VA worse than J3/J4 was 0.20, 95% CI 0.07 to 0.58; eyes = 782; studies = 8). We judged this to be low-certainty evidence because of risk of bias in the included studies and high heterogeneity (I 2 = 93%) although all included studies favoured multifocal lenses with respect to this outcome.People receiving multifocal lenses may be less spectacle dependent (RR 0.63, 95% CI 0.55 to 0.73; eyes = 1000; studies = 10). We judged this to be low-certainty evidence because of risk of bias and evidence of publication bias (skewed funnel plot). There was also high heterogeneity (I 2 = 67%) but all studies favoured multifocal lenses. We did not additionally downgrade for this.Adverse subjective visual phenomena were more prevalent and more troublesome in participants with a multifocal IOL compared with monofocals (RR for glare 1.41, 95% CI 1.03 to 1.93; eyes = 544; studies = 7, low-certainty evidence and RR for haloes 3.58, 95% CI 1.99 to 6.46; eyes = 662; studies = 7; moderate-certainty evidence).Two studies compared multifocal lenses with monovision. There was no evidence for any important differences in distance VA between the groups (mean difference (MD) 0.02 logMAR, 95% CI -0.02 to 0.06; eyes = 186; studies = 1), unaided intermediate VA (MD 0.07 logMAR, 95% CI 0.04 to 0.10; eyes = 181; studies = 1) and unaided near VA (MD -0.04, 95% CI -0.08 to 0.00; eyes = 186; studies = 1) compared with people receiving monovision. People receiving multifocal lenses were less likely to be spectacle dependent (RR 0.40, 95% CI 0.30 to 0.53; eyes = 262; studies = 2) but more likely to report problems with glare (RR 1.41, 95% CI 1.14 to 1.73; eyes = 187; studies = 1) compared with people receiving monovision. In one study, the investigators noted that more people in the multifocal group underwent IOL exchange in the first year after surgery (6 participants with multifocal vs 0 participants with monovision). Multifocal IOLs are effective at improving near vision relative to monofocal IOLs although there is uncertainty as to the size of the effect. Whether that improvement outweighs the adverse effects of multifocal IOLs, such as glare and haloes, will vary between people. Motivation to achieve spectacle independence is likely to be the deciding factor.
Yamauchi, Tomofusa; Tabuchi, Hitoshi; Takase, Kosuke; Ohsugi, Hideharu; Ohara, Zaigen; Kiuchi, Yoshiaki
2013-01-01
Purpose To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. Methods The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patients who were implanted with Tecnis® multifocal IOLs bilaterally. The monofocal group was an age- and sex-matched control group, and included 85 patients who were implanted with Tecnis® monofocal IOLs bilaterally. Lens opacity grading, the radius of corneal curvature, corneal astigmatism, axial length and the refractive status were measured preoperatively. Pupil size, ocular aberrometry, distance, intermediate and near visual acuity, contrast sensitivity with and without glare and the responses to a quality-of-vision questionnaire were evaluated pre- and postoperatively. Results The uncorrected near visual acuity was significantly better in the multifocal group, whereas both the corrected intermediate and near visual acuity were better in the monofocal group. Contrast sensitivity (with and without glare) was significantly better in the monofocal group. The rate of spectacle dependency was significantly lower in the multifocal group. There were no significant differences between the two groups regarding most items of the postoperative quality-of-vision questionnaire (VFQ-25), with the exception that the patients in the monofocal group reported fewer problems with nighttime driving. Conclusions The multifocal IOLs used in this study reduced spectacle dependency more so than monofocal IOLs and did not compromise the subjective visual function, with the exception of nighttime driving. PMID:23840836
Salemis, Nikolaos S; Seretis, Charalambos; Seretis, Fotios; Christofyllakis, Charalambos; Karalis, Georgios
2014-01-01
Multifocal soft tissue sarcoma is a rare clinical entity occurring in 1% of patients with extremity soft tissue sarcoma and in 4.5% of patients with liposarcoma. Multifocal disease may arise either synchronously or metachronously and has been associated with poor prognosis. Herein, we have described a rare case of metachronous multifocal myxoid liposarcoma involving the gastrointestinal tract that developed 14 months after the resection of a myxoid buttock liposarcoma. Diagnostic evaluation and management of the patient are discussed along with a review of the relevant literature. We conclude that multifocal myxoid liposarcoma is a rare clinical entity that usually represents metastatic disease with poor prognosis. A thorough imaging and careful physical examination are essential in the preoperative evaluation and postoperative follow-up of patients with myxoid extremity liposarcomas, as these tumors are known to have a tendency to spread toward extrapulmonary sites, frequently without pulmonary metastases.
Salemis, Nikolaos S.; Seretis, Charalambos; Seretis, Fotios; Christofyllakis, Charalambos; Karalis, Georgios
2014-01-01
Multifocal soft tissue sarcoma is a rare clinical entity occurring in 1% of patients with extremity soft tissue sarcoma and in 4.5% of patients with liposarcoma. Multifocal disease may arise either synchronously or metachronously and has been associated with poor prognosis. Herein, we have described a rare case of metachronous multifocal myxoid liposarcoma involving the gastrointestinal tract that developed 14 months after the resection of a myxoid buttock liposarcoma. Diagnostic evaluation and management of the patient are discussed along with a review of the relevant literature. We conclude that multifocal myxoid liposarcoma is a rare clinical entity that usually represents metastatic disease with poor prognosis. A thorough imaging and careful physical examination are essential in the preoperative evaluation and postoperative follow-up of patients with myxoid extremity liposarcomas, as these tumors are known to have a tendency to spread toward extrapulmonary sites, frequently without pulmonary metastases. PMID:24678225
MULTIFOCAL CHOROIDITIS IN DISSEMINATED SPOROTRICHOSIS IN PATIENTS WITH HIV/AIDS.
Biancardi, Ana L; Freitas, Dayvison F S; Valviesse, Vitor R G de A; Andrade, Hugo B; de Oliveira, Manoel M E; do Valle, Antonio C F; Zancope-Oliveira, Rosely M; Galhardo, Maria C G; Curi, Andre L L
2017-01-01
In this article, the authors describe multifocal choroiditis related to disseminated sporotrichosis in patients with HIV/AIDS. We conducted a retrospective observational study of three patients infected with HIV who presented with disseminated sporotrichosis characterized by cutaneous lesions, multifocal choroiditis, and other manifestations, including osteomyelitis and involvement of the bone marrow, larynx, pharynx, and nasal and oral mucosa. Five eyes of three patients with HIV/AIDS showed multifocal choroiditis related to disseminated sporotrichosis. The CD4 counts ranged from 25 to 53 mm. All patients were asymptomatic visually. The ocular disease was bilateral in two patients. The lesion size ranged from 1/3 to 2 disc diameters. None of the patients had vitritis. Of the 12 lesions, 9 were localized in the posterior pole (Zone 1) and 3 were localized in the mild periphery (Zone 2). Multifocal choroiditis due to disseminated sporotrichosis can occur in profoundly immunosuppressed patients with HIV/AIDS.
The multifocal electroretinogram in X-linked juvenile retinoschisis.
Huang, Shizhou; Wu, Dezheng; Jiang, Futian; Luo, Guangwei; Liang, Jiongji; Wen, Feng; Yu, Minzhong; Long, Shixian; Wu, Lezheng
2003-05-01
To measure and compare the multifocal electroretinography in normal control and X-linked juvenile retinoschisis, 13 cases (13 right eyes) of normal control and nine cases (17 eyes) of X-linked juvenile retinoschisis were measured with VERIS Science 4.0. Four cases (eight eyes) out of the nine retinoschisis cases were tested with Ganzfeld ERG at the same day. The results showed statistically significant difference of average response densities and latencies in six ring retinal regions between the normal control and retinoschisis. The trace array and 3-D topography of multifocal ERG showed multi-area amplitude decrease with absence or reduction of central peak amplitude in patients with retinoschisis. The P1/N1 ratio of multifocal ERG average response densities in six ring retinal regions was different from the b/a ratio of Ganzfeld ERG. The multifocal ERG and Ganzfeld ERG each had its advantage in the diagnosis of retinoschisis.
Multifocal Congenital Hemangiopericytoma.
Robl, Renata; Carvalho, Vânia Oliveira; Abagge, Kerstin Taniguchi; Uber, Marjorie; Lichtvan, Leniza Costa Lima; Werner, Betina; Mehrdad Nadji, Mehrdad
2017-01-01
Congenital hemangiopericytoma (HPC) is a rare mesenchymal tumor with less aggressive behavior and a more favorable prognosis than similar tumors in adults. Multifocal presentation is even less common than isolated HPC and hence its clinical and histologic recognition may be challenging. A newborn infant with multifocal congenital HPC causing severe deformity but with a favorable outcome after chemotherapy and surgical removal is reported. © 2016 Wiley Periodicals, Inc.
Kasi, Sundeep K; Vora, Robin A; Martin, Taliva; Cunningham, Emmett T
2015-01-01
To describe an unusual presentation of bilateral HIV-associated multifocal retinal infiltrates with phlebitis and optic neuropathy in a pediatric patient from Zimbabwe, Africa. Retrospective case report of a 15-year-old boy from Zimbabwe, Africa. The patient was found to have bilateral vitritis, multifocal retinitis with phlebitis, and optic neuropathy in the setting of previously unrecognized HIV infection. Vision improved and the clinical findings resolved after treatment with intravenous corticosteroids and highly active retroviral therapy (HAART). The authors describe the occurrence and treatment of bilateral, HIV-associated multifocal retinal infiltrates with phlebitis and HIV-associated optic neuropathy in a pediatric patient from Zimbabwe, Africa.
Glaser, Dee Anna; Ballard, Angela M; Hunt, Niquette L; Pieretti, Lisa J; Pariser, David M
2016-12-01
There is a paucity of data on the prevalence of multifocal primary hyperhidrosis and changes in hyperhidrosis severity over time. The goal of this study was to better understand multifocal primary hyperhidrosis, prevalence and distribution of hyperhidrosis by focal site, age of onset of symptoms by focal area, and change in hyperhidrosis severity over time and with seasons. The International Hyperhidrosis Society, through an unrestricted research grant from Revance Therapeutics, conducted an online survey of registered visitors to its Web site. Participants identified as having "excessive sweating" and opted to participate in the survey (23 questions) after an e-mail invitation. The survey data illustrate that multifocal primary hyperhidrosis is more common than previously believed and that multifocal hyperhidrosis is more common than singular focal hyperhidrosis (81% of patients reported 3 or more focal hyperhidrotic sites). The data also show that sweating symptom severity does not improve with age but stays the same or gets worse and is "bothersome" throughout the year. Recognition of the chronic and multifocal nature of primary hyperhidrosis is useful for treating hyperhidrosis patients long term and illustrates a need for treatments or treatment combinations that are effective for multiple body areas.
Temporal multiplexing with adaptive optics for simultaneous vision
Papadatou, Eleni; Del Águila-Carrasco, Antonio J.; Marín-Franch, Iván; López-Gil, Norberto
2016-01-01
We present and test a methodology for generating simultaneous vision with a deformable mirror that changed shape at 50 Hz between two vergences: 0 D (far vision) and −2.5 D (near vision). Different bifocal designs, including toric and combinations of spherical aberration, were simulated and assessed objectively. We found that typical corneal aberrations of a 60-year-old subject changes the shape of objective through-focus curves of a perfect bifocal lens. This methodology can be used to investigate subjective visual performance for different multifocal contact or intraocular lens designs. PMID:27867718
Is multifocality a prognostic factor in childhood hepatoblastoma?
Saettini, Francesco; Conter, Valentino; Provenzi, Massimo; Rota, Matteo; Giraldi, Eugenia; Foglia, Carlo; Cavalleri, Laura; D'Antiga, Lorenzo
2014-09-01
The aim of this study was to assess the prognostic value of multifocality and the effectiveness of two different therapeutic strategies in patients with newly diagnosed hepatoblastoma. Between 1998 and 2011, 31 patients diagnosed with hepatoblastoma were referred to Ospedale Papa Giovanni XXIII, Bergamo, Italy. Patients were stratified according to SIOPEL protocols into high-risk (HR if AFP <100 ng/mL and/or PRETEXT IV and/or vascular invasion and/or extra-hepatic intra-abdominal disease and/or metastases) and standard-risk (SR, all others). The patient data we evaluated were: multifocality; patient age; gender; platelet count; AFP level at diagnosis, during treatment and follow-up; histotype; gestational age; birth weight; surgery (either resection or transplantation) and chemotherapy regimen adopted before and after surgery. The outcome measures were event free survival (EFS) and overall survival (OS); survival curves were estimated according to Kaplan-Meier. EFS and OS were associated significantly with multifocality (3-year EFS 40% vs. 95%, P = 0.006; 3-year OS 42% vs. 95%, P = 0.004). Multivariate analysis demonstrated that multifocality predicts lower EFS (hazard ratio 10.01, P = 0.007). Other factors at diagnosis did not reach statistical significance. A marked treatment dependent improvement was associated with intensive chemotherapy given both before and after liver transplantation (P = 0.06). Patients diagnosed with multifocal tumors had lower EFS levels. Multifocality should be taken into account for future stratification and further studied to assess genetic profile, immunochemistry and prognostic role. © 2014 Wiley Periodicals, Inc.
Hayashi, Ken; Yoshida, Motoaki; Hayashi, Hideyuki
2009-03-01
To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL. Comparative, nonrandomized, interventional study. Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL. All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs. At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances. Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P
Cortical Circuit for Binding Object Identity and Location During Multiple-Object Tracking
Nummenmaa, Lauri; Oksama, Lauri; Glerean, Erico; Hyönä, Jukka
2017-01-01
Abstract Sustained multifocal attention for moving targets requires binding object identities with their locations. The brain mechanisms of identity-location binding during attentive tracking have remained unresolved. In 2 functional magnetic resonance imaging experiments, we measured participants’ hemodynamic activity during attentive tracking of multiple objects with equivalent (multiple-object tracking) versus distinct (multiple identity tracking, MIT) identities. Task load was manipulated parametrically. Both tasks activated large frontoparietal circuits. MIT led to significantly increased activity in frontoparietal and temporal systems subserving object recognition and working memory. These effects were replicated when eye movements were prohibited. MIT was associated with significantly increased functional connectivity between lateral temporal and frontal and parietal regions. We propose that coordinated activity of this network subserves identity-location binding during attentive tracking. PMID:27913430
Lee, Andrew R; Sharma, Sumit; Mahmoud, Tamer H
2017-01-01
To report a case of tubulointerstitial nephritis and uveitis syndrome with a primary presentation of acute posterior multifocal placoid pigment epitheliopathy after use of lamotrigine. Retrospective case report with ultra-widefield fundus imaging, optical coherence tomography, and fluorescein angiography. A 19-year-old woman presented with decreased visual acuity and acute renal failure after starting lamotrigine. Her examination demonstrated 1+ anterior chamber cell and numerous white deep retinal plaque-like lesions predominantly in the macula in both eyes. After extensive ophthalmic and systemic evaluation, the patient was diagnosed with tubulointerstitial nephritis and uveitis syndrome with a primary presentation of acute posterior multifocal placoid pigment epitheliopathy. She had excellent visual recovery with topical and systemic steroids. Acute posterior multifocal placoid pigment epitheliopathy is a rare but important clinical presentation of tubulointerstitial nephritis and uveitis syndrome. Oral corticosteroid treatment can be considered for tubulointerstitial nephritis but is generally not necessary for acute posterior multifocal placoid pigment epitheliopathy.
Hayashi, Ken; Manabe, Shin-Ichi; Hayashi, Hideyuki
2009-12-01
To compare visual acuity from far to near, contrast visual acuity, and acuity in the presence of glare (glare visual acuity) between an aspheric diffractive multifocal intraocular lens (IOL) with a low addition (add) power (+3.0 diopters) and a monofocal IOL. Hayashi Eye Hospital, Fukuoka, Japan. This prospective study comprised patients having implantation of an aspheric diffractive multifocal ReSTOR SN6AD1 IOL with a +3.0 D add (multifocal group) or a monofocal AcrySof IQ SN60WF IOL (monofocal group). Visual acuity from far to near distances, contrast acuity, and glare acuity were evaluated 3 months postoperatively. Each IOL group comprised 64 eyes of 32 patients. For monocular and binocular visual acuity, the mean uncorrected and distance-corrected intermediate acuity at 0.5 m and the near acuity at 0.3 m were significantly better in the multifocal group than in the monofocal group (P=.0035); distance and intermediate acuity at 0.7 m and 1.0 m were similar between the 2 groups. No significant differences were observed between groups in contrast acuity and glare acuity under photopic and mesopic conditions. Furthermore, no significant correlation was found between all-distance acuity and pupil diameter or between visual acuity and IOL decentration and tilt. The diffractive multifocal IOL with a low add power provided significantly better intermediate and near visual acuity than the monofocal IOL. Contrast sensitivity with and without glare was reduced with the multifocal IOL, and all-distance visual acuity was independent of pupil diameter and IOL displacement.
Card, Timothy; Xu, Jing; Liang, Huifang; Bhayat, Fatima
2018-04-23
Progressive multifocal leukoencephalopathy is a serious condition linked to certain diseases and immunosuppressant therapies, including the α4 integrin antagonist natalizumab. No cases have been reported to date with vedolizumab, a selective antagonist of the α4β7 integrin expressed on gut-homing lymphocytes. This analysis aimed to describe the current and future expected occurrence of progressive multifocal leukoencephalopathy with vedolizumab use, were the risk the same as in other populations in which this disease has been studied. The expected number of vedolizumab-associated progressive multifocal leukoencephalopathy cases was estimated up to May 19, 2016, and modeled up to 2034. These estimates were based on the cumulative exposure to the drug, assuming an equivalent risk to that of patients treated with natalizumab or those from other reference populations where progressive multifocal leukoencephalopathy has been examined. Future cases were modeled based on similar risks and projected sales. The cumulative vedolizumab exposure was estimated at 54,619 patient-years, with a 95% confidence interval of 0.0 to 6.75 cases per 100,000 patient-years. An estimated 30.2 (95% confidence interval, 19.4-40.9) cases of progressive multifocal leukoencephalopathy would have occurred if vedolizumab had the same risk as that of natalizumab. There would be a 50% chance of the first case occurring by 2018, assuming an equivalent risk to the general population. These analyses indicate that the risk of progressive multifocal leukoencephalopathy with vedolizumab is small, and unlikely to be above 6.75 cases per 100,000 patient-years.
Predicting through-focus visual acuity with the eye's natural aberrations.
Kingston, Amanda C; Cox, Ian G
2013-10-01
To develop a predictive optical modeling process that utilizes individual computer eye models along with a novel through-focus image quality metric. Individual eye models were implemented in optical design software (Zemax, Bellevue, WA) based on evaluation of ocular aberrations, pupil diameter, visual acuity, and accommodative response of 90 subjects (180 eyes; 24-63 years of age). Monocular high-contrast minimum angle of resolution (logMAR) acuity was assessed at 6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, 33 cm, 28 cm, and 25 cm. While the subject fixated on the lowest readable line of acuity, total ocular aberrations and pupil diameter were measured three times each using the Complete Ophthalmic Analysis System (COAS HD VR) at each distance. A subset of 64 mature presbyopic eyes was used to predict the clinical logMAR acuity performance of five novel multifocal contact lens designs. To validate predictability of the design process, designs were manufactured and tested clinically on a population of 24 mature presbyopes (having at least +1.50 D spectacle add at 40 cm). Seven object distances were used in the validation study (6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, and 25 cm) to measure monocular high-contrast logMAR acuity. Baseline clinical through-focus logMAR was shown to correlate highly (R² = 0.85) with predicted logMAR from individual eye models. At all object distances, each of the five multifocal lenses showed less than one line difference, on average, between predicted and clinical normalized logMAR acuity. Correlation showed R² between 0.90 and 0.97 for all multifocal designs. Computer-based models that account for patient's aberrations, pupil diameter changes, and accommodative amplitude can be used to predict the performance of contact lens designs. With this high correlation (R² ≥ 0.90) and high level of predictability, more design options can be explored in the computer to optimize performance before a lens is manufactured and tested clinically.
Non-descanned multifocal multiphoton microscopy with a multianode photomultiplier tube
Cha, Jae Won; Yew, Elijah Y. S.; Kim, Daekeun; Subramanian, Jaichandar; Nedivi, Elly; So, Peter T. C.
2015-01-01
Multifocal multiphoton microscopy (MMM) improves imaging speed over a point scanning approach by parallelizing the excitation process. Early versions of MMM relied on imaging detectors to record emission signals from multiple foci simultaneously. For many turbid biological specimens, the scattering of emission photons results in blurred images and degrades the signal-to-noise ratio (SNR). We have recently demonstrated that a multianode photomultiplier tube (MAPMT) placed in a descanned configuration can effectively collect scattered emission photons from each focus into their corresponding anodes significantly improving image SNR for highly scattering specimens. Unfortunately, a descanned MMM has a longer detection path resulting in substantial emission photon loss. Optical design constraints in a descanned geometry further results in significant optical aberrations especially for large field-of-view (FOV), high NA objectives. Here, we introduce a non-descanned MMM based on MAPMT that substantially overcomes most of these drawbacks. We show that we improve signal efficiency up to fourfold with limited image SNR degradation due to scattered emission photons. The excitation foci can also be spaced wider to cover the full FOV of the objective with minimal aberrations. The performance of this system is demonstrated by imaging interneuron morphological structures deep in the brains of living mice. PMID:25874160
Yang, L M; Li, Q; Zhao, B W; Lyu, J G; Xu, H S; Xu, L L; Li, S Y; Gao, L; Zhu, J
2017-04-07
Objective: To investigate the occurrence of occult carcinoma in contralateral lobes based on the ultrasonic features of unilateral papillary thyroid carcinoma. Methods: The study included 202 consecutives cases of unilateral papillary thyroid carcinoma with benign nodules in the contralateral lobe identified by preoperative ultrasound or fine-needle aspiration from June 2014 to December 2015. All patients received total thyroidectomies, and with postoperative pathological examination they were divided into two groups, one including 60 cases with positive occult cancer and another one consisting of 142 cases with negative occult cancer. Univariate and multivariate analyses were performed to analyze the sonographic features of unilateral papillary thyroid carcinoma relevant to the occurrence of occult carcinoma in the contralateral nodules. Results: Univariate analysis indicated occult carcinoma in the contralateral lobes was associated with Hashimoto's thyroiditis(χ(2)=3.955, P =0.047), unclear border (χ(2)=4.375, P =0.036)and multifocality in the ipsilateral(χ(2)=7.375, P =0.007), but not with tumors maximum size, location, A/T, shape, internal structure, internal echo, acoustic halo, calcification, capsular invasion and blood flow signal in the lobe with carcinoma on another side. Multivariate analysis showed unclear border ( OR =2.727, P =0.010) and multifocality in the ipsilateral( OR =2.807, P =0.005)of carcinoma were independent predictive factor for contralateral occult PTC. Conclusions: Unclear border and multifocality of PTC in the ipsilateral were closely relevant to the occurrence of occult carcinoma in the contralateral nodules.
NASA Astrophysics Data System (ADS)
Rotenstreich, Ygal; Chibel, Ron; Haj Yahia, Soad; Achiron, Asaf; Mahajna, Mohamad; Belkin, Michael; Sher, Ifat
2015-03-01
We recently demonstrated the feasibility of quantifying pupil responses (PR) to multifocal chromatic light stimuli for objectively assessing visual field (VF). Here we assessed a second-generation chromatic multifocal pupillometer device with 76 LEDs of 18 degree visual field and a smaller spot size (2mm diameter), aimed of achieving better perimetric resolution. A computerized infrared pupillometer was used to record PR to short- and long-wavelength stimuli (peak 485 nm and 640 nm, respectively) presented by 76 LEDs, 1.8mm spot size, at light intensities of 10-1000 cd/m2 at different points of the 18 degree VF. PR amplitude was measured in 11 retinitis pigmentosa (RP) patients and 20 normal agedmatched controls. RP patients demonstrated statistically significant reduced pupil contraction amplitude in majority of perimetric locations under testing conditions that emphasized rod contribution (short-wavelength stimuli at 200 cd/m2) in peripheral locations (p<0.05). By contrast, the amplitude of pupillary responses under testing conditions that emphasized cone cell contribution (long-wavelength stimuli at 1000 cd/m2) were not significantly different between the groups in majority of perimetric locations, particularly in central locations. Minimal pupil contraction was recorded in areas that were non-detected by chromatic Goldmann. This study demonstrates the feasibility of using pupillometerbased chromatic perimetry for objectively assessing VF defects and retinal function in patients with retinal degeneration. This method may be used to distinguish between the damaged cells underlying the VF defect.
Optical super resolution using tilted illumination coupled with object rotation
NASA Astrophysics Data System (ADS)
Hussain, Anwar; Mudassar, Asloob A.
2015-03-01
In conventional imaging systems, the resolution of the final image is mainly distorted due to diffraction of higher spatial frequencies of the target object. To overcome the diffraction limit, imaging techniques which synthetically enlarge the aperture of the system are used. In this paper, synthesized aperture is produced by means of a three fiber illumination assembly coupled with an in-plane object rotation. The high order diffracted spatial frequencies of the object are brought into the pass band of optical system by illuminating the object with tilted beams. The tilt produced at the fiber assembly plane is related to the dimension of the aperture, placed at the Fourier plane of the system. To span the 2D object spectrum at the Fourier plane, an in-plane object rotation procedure is applied at the object plane. The spectrum of the object is rotated as the object is rotated and illuminated with tilted beams. The corresponding object beam is interfered with a reference beam from the same source to record interferograms. All the recorded interferograms are stored in computer and de-convolution algorithm is applied to recover the synthesized spectrum. The image of the synthesized spectrum has three times improved resolution compared to the conventional image.
Hayashi, Ken; Masumoto, Miki; Takimoto, Minehiro
2015-01-01
To compare visual outcomes between patients with a multifocal toric intraocular lens (IOL) and those with a monofocal toric IOL. Hayashi Eye Hospital, Fukuoka, Japan. Prospective case-control series. Eyes with preoperative corneal astigmatism between 0.75 diopter (D) and 2.82 D scheduled for implantation of a diffractive multifocal toric IOL (Restor SND1T) or monofocal toric IOL (Acrysof SN6AT) were recruited. Three months postoperatively, visual acuity at various distances, contrast visual acuity, and refractive outcomes were examined. Each group comprised 66 eyes (33 patients). Postoperatively, the mean refractive astigmatism decreased to 0.71 D in the multifocal group and 0.74 D in the monofocal group. The mean monocular and binocular uncorrected and corrected near visual acuity at 0.3 m and intermediate visual acuity at 0.5 m were significantly better in the multifocal group than in the monofocal group (P≤.0011). The uncorrected and corrected visual acuities at other distances were similar between groups except at 1.0 m. Binocular photopic and mesopic contrast visual acuities at high to moderate contrasts did not differ significantly between groups; however, acuities at low contrasts were worse in the multifocal group (P≤.0429). Diffractive multifocal toric IOL implantation decreased refractive astigmatism to an acceptable range in eyes with moderate corneal astigmatism and provided useful visual acuity (≥20/40) at any distance and significantly better near and intermediate visual acuity than a monofocal toric IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
[Relevance of the sentinel lymph node biopsy in breast multifocal and multicentric cancer].
Mosbah, R; Raimond, E; Pelissier, A; Hocedez, C; Graesslin, O
2015-05-01
The sentinel lymph node biopsy is a gold standard in the management of breast cancer. Its role in multifocal or multicentric tumors is still evolving. The aim of this study is to assess the feasibility and pertinence of sentinel lymph node biopsy in multifocal and multicentric tumors based on a systematic review of literature. A systematic review was conducted searching in the following electronic databases PubMed using "sentinel lymph node biopsy", "breast cancer", "multifocal tumor", "multicentric tumor" and "multiple tumor" as keywords. We included original articles published between 2000 and 2014, both French and English, studying feasibility of sentinel lymph node biopsy in invasive breast cancer, multicentric and/or multifocal tumors. The first end point was success rate and false negative rate. Twenty-six articles were included in this literature review, with 2212 cases (782 multifocal, 737 multicentric and 693 multiple tumors). Percentage of tumors whose stage was higher than stage T2 ranged from 0 to 86.3%. Success rate average was 83.1%. False negative average was 8.2%. False negative rate was less than 10% in 15 articles. Mean of sentinel lymph node biopsy was 2 (1-9). The average rate of sentinel lymph node positive was 50.6%. Axillary recurrence rate was 0.5%. Despite the methodological biases of the studies included in this review of literature, the false negative rate of sentinel node biopsy in multifocal and multicentric breast cancers are less than 10% with a low rate of axillary recurrence. Despite the lack of randomized study, this procedure can be routinely performed in accordance with rigorous technical process. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Garzón, Nuria; Poyales, Francisco; de Zárate, Begoña Ortíz; Ruiz-García, Jose Luis; Quiroga, Juan Antonio
2015-02-01
To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin, Germany], enVista [Bausch & Lomb, Rochester, NY], and AcrySof IQ [Alcon Laboratories, Inc., Fort Worth, TX]) and one multifocal toric IOL (AcrySof IQ ReSTOR; Alcon Laboratories, Inc.) were implanted. Preoperative and postoperative images were taken to calculate the misalignment due to the marking method. To evaluate rotation in the different follow-up visits, another photograph was taken 1 hour and 1, 7 and 30 days postoperatively. Refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity were measured 30 days postoperatively. Postoperative UDVA was 0.1 logMAR or better in 64.6% of eyes implanted with monofocal IOLs and 46.4% of eyes implanted with multifocal IOLs. The enVista toric IOL showed the best UDVA compared to the other monofocal IOLs, with 81% of eyes with 0.1 logMAR or better. The mean misalignment in the total group studied was 0.07° ± 0.60°; 69.6% of monofocal IOLs and 67.9% of multifocal IOLs showed less than 5° of rotation. A correlation was found between postoperative UDVA and rotation in the monofocal and multifocal IOLs implanted (r = 0.439 [P < .011] and = 0.787 [P = .001], respectively). At 1 month postoperatively, UDVA was slightly more affected by IOL rotation in multifocal than monofocal toric IOLs. The marking method was also effective. Copyright 2015, SLACK Incorporated.
Ito, Misae; Shimizu, Kimiya
2009-09-01
To the compare the reading ability after bilateral cataract surgery in patients who had pseudophakic monovision achieved by monofocal intraocular lens (IOL) implantation and patients who had refractive multifocal IOL implantation. Department of Ophthalmology, Kitasato University Hospital, Kanagawa, Japan. This study evaluated patients who had bilateral cataract surgery using the monovision method with monofocal IOL implantation to correct presbyopia (monovision group) or who had bilateral cataract surgery with refractive multifocal IOL implantation (multifocal group). In the monovision group, the dominant eye was corrected for distance vision and the nondominant eye for near vision. The maximum reading speed, critical character size, and reading acuity were measured binocularly without refractive correction using MNREAD-J acuity charts. The monovision group comprised 38 patients and the multifocal group, 22 patients. The mean maximum reading speed was 350.5 characters per minute (cpm) +/- 62.3 (SD) in the monovision group and 355.0 +/- 53.3 cpm in the multifocal group; the difference was not statistically significant. The mean critical character size was 0.24 +/- 0.12 logMAR and 0.40 +/- 0.16 logMAR, respectively (P<.05). The mean reading acuity was 0.05 +/- 0.12 logMAR and 0.19 +/- 0.11 logMAR, respectively (P<.01). The monovision group had better critical character size and reading acuity results. The monovision method group had better reading ability; however, careful patient selection is essential.
Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F
2014-08-01
To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.
System for interferometric distortion measurements that define an optical path
Bokor, Jeffrey; Naulleau, Patrick
2003-05-06
An improved phase-shifting point diffraction interferometer can measure both distortion and wavefront aberration. In the preferred embodiment, the interferometer employs an object-plane pinhole array comprising a plurality of object pinholes located between the test optic and the source of electromagnetic radiation and an image-plane mask array that is positioned in the image plane of the test optic. The image-plane mask array comprises a plurality of test windows and corresponding reference pinholes, wherein the positions of the plurality of pinholes in the object-plane pinhole array register with those of the plurality of test windows in image-plane mask array. Electromagnetic radiation that is directed into a first pinhole of object-plane pinhole array thereby creating a first corresponding test beam image on the image-plane mask array. Where distortion is relatively small, it can be directly measured interferometrically by measuring the separation distance between and the orientation of the test beam and reference-beam pinhole and repeating this process for at least one other pinhole of the plurality of pinholes of the object-plane pinhole array. Where the distortion is relative large, it can be measured by using interferometry to direct the stage motion, of a stage supporting the image-plane mask array, and then use the final stage motion as a measure of the distortion.
NASA Astrophysics Data System (ADS)
Lee, Chang-Kun; Moon, Seokil; Lee, Byounghyo; Jeong, Youngmo; Lee, Byoungho
2016-10-01
A head-mounted compressive three-dimensional (3D) display system is proposed by combining polarization beam splitter (PBS), fast switching polarization rotator and micro display with high pixel density. According to the polarization state of the image controlled by polarization rotator, optical path of image in the PBS can be divided into transmitted and reflected components. Since optical paths of each image are spatially separated, it is possible to independently focus both images at different depth positions. Transmitted p-polarized and reflected s-polarized images can be focused by convex lens and mirror, respectively. When the focal lengths of the convex lens and mirror are properly determined, two image planes can be located in intended positions. The geometrical relationship is easily modulated by replacement of the components. The fast switching of polarization realizes the real-time operation of multi-focal image planes with a single display panel. Since it is possible to conserve the device characteristic of single panel, the high image quality, reliability and uniformity can be retained. For generating 3D images, layer images for compressive light field display between two image planes are calculated. Since the display panel with high pixel density is adopted, high quality 3D images are reconstructed. In addition, image degradation by diffraction between physically stacked display panels can be mitigated. Simple optical configuration of the proposed system is implemented and the feasibility of the proposed method is verified through experiments.
Speckle correlation method used to measure object's in-plane velocity.
Smíd, Petr; Horváth, Pavel; Hrabovský, Miroslav
2007-06-20
We present a measurement of an object's in-plane velocity in one direction by the use of the speckle correlation method. Numerical correlations of speckle patterns recorded periodically during motion of the object under investigation give information used to evaluate the object's in-plane velocity. The proposed optical setup uses a detection plane in the image field and enables one to detect the object's velocity within the interval (10-150) microm x s(-1). Simulation analysis shows a way of controlling the measuring range. The presented theory, simulation analysis, and setup are verified through an experiment of measurement of the velocity profile of an object.
Edelman, Frederick; Naddaf, Elie; Waclawik, Andrew J
2015-06-01
We present a 10-year-old boy with a predominantly motor multifocal neuropathy with demyelinating and axonal changes with sensory involvement, affecting only one upper extremity. Laboratory studies revealed an elevated titer of immunoglobulin M (IgM) antibodies against the NS6S antigen. He responded to treatment with high dose intravenous immunoglobulins. Focal or multifocal immune-mediated neuropathies are not common in children and may be underdiagnosed. © The Author(s) 2014.
ERIC Educational Resources Information Center
Kapucu, Serkan
2017-01-01
This study investigates how the acceleration and speed of a light-emitting object on an inclined plane may be determined using a smartphone's light sensor. A light-emitting object was released from the top of an inclined plane and its illuminance values were detected by a smartphone's light sensor during its subsequent motion down the plane. Using…
Yoon, Pil Whan; Yoo, Jeong Joon; Yoon, Kang Sup; Kim, Hee Joong
2012-03-01
Subchondral stress fractures of the femoral head may be either of the insufficiency-type with poor quality bone or the fatigue-type with normal quality bone but subject to high repetitive stresses. Unlike osteonecrosis, multiple site involvement rarely has been reported for subchondral stress fractures. We describe a case of multifocal subchondral stress fractures involving femoral heads and medial tibial condyles bilaterally within 2 weeks. A 27-year-old military recruit began having left knee pain after 2 weeks of basic training, without any injury. Subsequently, right knee, right hip, and left hip pain developed sequentially within 2 weeks. The diagnosis of multifocal subchondral stress fracture was confirmed by plain radiographs and MR images. Nonoperative treatment of the subchondral stress fractures of both medial tibial condyles and the left uncollapsed femoral head resulted in resolution of symptoms. The collapsed right femoral head was treated with a fibular strut allograft to restore congruity and healed without further collapse. There has been one case report in which an insufficiency-type subchondral stress fracture of the femoral head and medial femoral condyle occurred within a 2-year interval. Because the incidence of bilateral subchondral stress fractures of the femoral head is low and multifocal involvement has not been reported, multifocal subchondral stress fractures can be confused with multifocal osteonecrosis. Our case shows that subchondral stress fractures can occur in multiple sites almost simultaneously.
Paulsson, Anna K.; Holmes, Jordan A.; Peiffer, Ann M.; Miller, Lance D.; Liu, Wennuan; Xu, Jianfeng; Hinson, William H.; Lesser, Glenn J.; Laxton, Adrian W.; Tatter, Stephen B.; Debinski, Waldemar
2014-01-01
We investigate the differences in molecular signature and clinical outcomes between multiple lesion glioblastoma (GBM) and single focus GBM in the modern treatment era. Between August 2000 and May 2010, 161 patients with GBM were treated with modern radiotherapy techniques. Of this group, 33 were considered to have multiple lesion GBM (25 multifocal and 8 multicentric). Patterns of failure, time to progression and overall survival were compared based on whether the tumor was considered a single focus or multiple lesion GBM. Genomic groupings and methylation status were also investigated as a possible predictor of multifocality in a cohort of 41 patients with available tissue for analysis. There was no statistically significant difference in overall survival (p < 0.3) between the multiple lesion tumors (8.2 months) and single focus GBM (11 months). Progression free survival was superior in the single focus tumors (7.1 months) as compared to multi-focal (5.6 months, p = 0.02). For patients with single focus, multifocal and multicentric GBM, 81, 76 and 88 % of treatment failures occurred in the 60 Gy volume (p < 0.5), while 54, 72, and 38 % of treatment failures occurred in the 46 Gy volume (p < 0.4). Out of field failures were rare in both single focus and multiple foci GBM (7 vs 3 %). Genomic groupings and methylation status were not found to predict for multifocality. Patterns of failure, survival and genomic signatures for multiple lesion GBM do not appreciably differ when compared to single focus tumors. PMID:24990827
Park, Jin Young; Kim, Dong Wook; Park, Ha Kyung; Ha, Tae Kwun; Jung, Soo Jin; Kim, Do Hun; Bae, Sang Kyun
2015-01-01
This study aimed to assess the relationship between coexisting lymphocytic thyroiditis and T-N stages of papillary thyroid carcinoma (PTC) by histopathological analysis. The study included 653 patients who underwent thyroid surgery for PTC at our hospital. Each case was classified as either Hashimoto's thyroiditis (HT), non-Hashimoto type of lymphocytic thyroiditis (NHLT), or normal according to the histopathology of thyroid parenchyma. Patient age, gender, surgical modality, location, T stage, N stage, multifocality and bilaterality were compared according to the histopathology. The prevalence of coexisting lymphocytic thyroiditis was 25.8% (169/653); HT (7.5%, 49/653) and NHLT (18.3%, 120/653). There were no significant differences in T stage, N stage, multifocality and bilaterality with regard to coexisting lymphocytic thyroiditis, regardless of whether HT and NHLT were considered collectively or discretely. Primary tumor size (p < 0.0001), location (p = 0.0011), N stage (p < 0.0001), multifocality (p < 0.0001) and bilaterality (p < 0.0001) differed significantly according to T stage, and gender (p = 0.0193), primary tumor size (p < 0.0001), T stage (p < 0.0001), multifocality (p < 0.0001) and bilaterality (p < 0.0001) differed significantly according to N stage. PTC patients with coexisting lymphocytic thyroiditis did not differ from those with normal parenchyma in terms of T stage, N stage, multifocality and bilaterality.
The application of digital image plane holography technology to identify Chinese herbal medicine
NASA Astrophysics Data System (ADS)
Wang, Huaying; Guo, Zhongjia; Liao, Wei; Zhang, Zhihui
2012-03-01
In this paper, the imaging technology of digital image plane holography to identify the Chinese herbal medicine is studied. The optical experiment system of digital image plane holography which is the special case of pre-magnification digital holography was built. In the record system, one is an object light by using plane waves which illuminates the object, and the other one is recording hologram by using spherical light wave as reference light. There is a Micro objective lens behind the object. The second phase factor which caus ed by the Micro objective lens can be eliminated by choosing the proper position of the reference point source when digital image plane holography is recorded by spherical light. In this experiment, we use the Lygodium cells and Onion cells as the object. The experiment results with Lygodium cells and Onion cells show that digital image plane holography avoid the process of finding recording distance by using auto-focusing approach, and the phase information of the object can be reconstructed more accurately. The digital image plane holography is applied to the microscopic imaging of cells more effectively, and it is suit to apply for the identify of Chinese Herbal Medicine. And it promotes the application of digital holographic in practice.
Chibel, Ron; Sher, Ifat; Ben Ner, Daniel; Mhajna, Mohamad O; Achiron, Asaf; Hajyahia, Soad; Skaat, Alon; Berchenko, Yakir; Oberman, Bernice; Kalter-Leibovici, Ofra; Freedman, Laurence; Rotenstreich, Ygal
2016-09-01
To assess visual field (VF) defects and retinal function objectively in healthy participants and patients with retinitis pigmentosa (RP) using a chromatic multifocal pupillometer. Cross-sectional study. The right eyes of 16 healthy participants and 13 RP patients. Pupil responses to red and blue light (peak, 485 and 625 nm, respectively) presented by 76 light-emitting diodes, 1.8-mm spot size at different locations of a 16.2° VF were recorded. Subjective VFs of RP patients were determined using chromatic dark-adapted Goldmann VFs (CDA-GVFs). Six healthy participants underwent 2 pupillometer examinations to determine test-retest reliability. Three parameters of pupil contraction were determined automatically: percentage of change of pupil size (PPC), maximum contraction velocity (MCV; in pixels per second), and latency of MCV (LMCV; in seconds). The fraction of functional VF was determined by CDA-GVF. In healthy participants, higher PPC and MCV were measured in response to blue compared with red light. The LMCV in response to blue light was relatively constant throughout the VF. Healthy participants demonstrated higher PPC and MCV and shorter LMCV in central compared with peripheral test points in response to red light. Test-retest correlation coefficients were 0.7 for PPC and 0.5 for MCV. In RP patients, test point in which the PPC and MCV were lower than 4 standard errors from the mean of healthy participants correlated with areas that were indicated as nonseeing by CDA-GVF. The mean absolute deviation in LMCV parameter in response to the red light between different test point was significantly higher in RP patients (range, 0.16-0.47) than in healthy participants (range, 0.02-0.16; P < 0.0001) and indicated its usefulness as a diagnostic tool with high sensitivity and specificity (area under the receiver operating characteristic curve (AUC), 0.97, Mann-Whitney-Wilcoxon analysis). Randomly reducing the number of test points to a total of 15 points did not significantly reduce the AUC in RP diagnosis based on this parameter. This study demonstrates the feasibility of using a chromatic multifocal pupillometer for objective diagnosis of RP and assessment of VF defects. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Early evolution of multifocal optics for well-focused colour vision in vertebrates.
Gustafsson, O S E; Collin, S P; Kröger, R H H
2008-05-01
Jawless fishes (Agnatha; lampreys and hagfishes) most closely resemble the earliest stage in vertebrate evolution and lamprey-like animals already existed in the Lower Cambrian [about 540 million years ago (MYA)]. Agnathans are thought to have separated from the main vertebrate lineage at least 500 MYA. Hagfishes have primitive eyes, but the eyes of adult lampreys are well-developed. The southern hemisphere lamprey, Geotria australis, possesses five types of opsin genes, three of which are clearly orthologous to the opsin genes of jawed vertebrates. This suggests that the last common ancestor of all vertebrate lineages possessed a complex colour vision system. In the eyes of many bony fishes and tetrapods, well-focused colour images are created by multifocal crystalline lenses that compensate for longitudinal chromatic aberration. To trace the evolutionary origins of multifocal lenses, we studied the optical properties of the lenses in four species of lamprey (Geotria australis, Mordacia praecox, Lampetra fluviatilis and Petromyzon marinus), with representatives from all three of the extant lamprey families. Multifocal lenses are present in all lampreys studied. This suggests that the ability to create well-focused colour images with multifocal optical systems also evolved very early.
Ledesma-Montes, Constantino; Mendez-Mendoza, Amilcar
2017-01-01
Multifocal epithelial hyperplasia is an uncommon disease of the oral mucosa caused by the human papilloma virus. To study the clinical and pathological findings of multifocal epithelial hyperplasia detected during an oral examination of 343 Mexican Nahuatl children from a single primary school in El Paso de Cupilco, Mexico. A thorough oral examination was performed in all children and clinical data (age, gender, location and number of lesions) were documented and analyzed. Multifocal epithelial hyperplasia was diagnosed in 110 of the 343 children (32.3%). The ages of the children varied from 5 to 15 years, and of these, 56.3% were girls. The lesions were asymptomatic, 0.2 to 3.0 cm in diameter, soft, round to oval, smooth surfaced, sessile papulonodules, similar in colour to that of the surrounding mucosa. The lesions were commonly seen on the buccal mucosa and tongue, and most affected children (85%) had less than 5 lesions. Children in the 7 to 10 years age group were most often affected. Human papillomavirus typing was not done owing to a lack of facilities. There is a high incidence of multifocal epithelial hyperplasia in Nahuatl children with a predilection for females.
Analysis of Rapid Multi-Focal Zone ARFI Imaging
Rosenzweig, Stephen; Palmeri, Mark; Nightingale, Kathryn
2015-01-01
Acoustic radiation force impulse (ARFI) imaging has shown promise for visualizing structure and pathology within multiple organs; however, because the contrast depends on the push beam excitation width, image quality suffers outside of the region of excitation. Multi-focal zone ARFI imaging has previously been used to extend the region of excitation (ROE), but the increased acquisition duration and acoustic exposure have limited its utility. Supersonic shear wave imaging has previously demonstrated that through technological improvements in ultrasound scanners and power supplies, it is possible to rapidly push at multiple locations prior to tracking displacements, facilitating extended depth of field shear wave sources. Similarly, ARFI imaging can utilize these same radiation force excitations to achieve tight pushing beams with a large depth of field. Finite element method simulations and experimental data are presented demonstrating that single- and rapid multi-focal zone ARFI have comparable image quality (less than 20% loss in contrast), but the multi-focal zone approach has an extended axial region of excitation. Additionally, as compared to single push sequences, the rapid multi-focal zone acquisitions improve the contrast to noise ratio by up to 40% in an example 4 mm diameter lesion. PMID:25643078
Brainstem auditory evoked responses in an equine patient population: part I--adult horses.
Aleman, M; Holliday, T A; Nieto, J E; Williams, D C
2014-01-01
Brainstem auditory evoked response has been an underused diagnostic modality in horses as evidenced by few reports on the subject. To describe BAER findings, common clinical signs, and causes of hearing loss in adult horses. Study group, 76 horses; control group, 8 horses. Retrospective. BAER records from the Clinical Neurophysiology Laboratory were reviewed from the years of 1982 to 2013. Peak latencies, amplitudes, and interpeak intervals were measured when visible. Horses were grouped under disease categories. Descriptive statistics and a posthoc Bonferroni test were performed. Fifty-seven of 76 horses had BAER deficits. There was no breed or sex predisposition, with the exception of American Paint horses diagnosed with congenital sensorineural deafness. Eighty-six percent (n = 49/57) of the horses were younger than 16 years of age. The most common causes of BAER abnormalities were temporohyoid osteoarthropathy (THO, n = 20/20; abnormalities/total), congenital sensorineural deafness in Paint horses (17/17), multifocal brain disease (13/16), and otitis media/interna (4/4). Auditory loss was bilateral and unilateral in 74% (n = 42/57) and 26% (n = 15/57) of the horses, respectively. The most common causes of bilateral auditory loss were sensorineural deafness, THO, and multifocal brain disease whereas THO and otitis were the most common causes of unilateral deficits. Auditory deficits should be investigated in horses with altered behavior, THO, multifocal brain disease, otitis, and in horses with certain coat and eye color patterns. BAER testing is an objective and noninvasive diagnostic modality to assess auditory function in horses. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Photodynamic therapy of vulvar intraepithelial neoplasia using 5-aminolevulinic acid.
Hillemanns, P; Untch, M; Dannecker, C; Baumgartner, R; Stepp, H; Diebold, J; Weingandt, H; Pröve, F; Korell, M
2000-03-01
Photodynamic (PDT) therapy is a relatively new technique with unique properties that make it attractive for the local treatment of superficial epithelial disorders. The objective of this study was to investigate the clinical response of PDT with the photosensitizing agent 5-aminolevulinic acid (5-ALA) in patients with vulvar intraepithelial neoplasia (VIN) grades 1 to 3. Twenty-five patients with 111 lesions of VIN 1-3 were topically sensitized with 10 ml of a 20% solution of 5-ALA and treated with 57 cycles of laser light at 635 nm (100 J/cm(2)). Seventy (64%) of the 111 VIN lesions regressed after various PDT cycles. A complete response was achieved in 13 patients (52%) with 27 lesions. All patients with VIN 1 and mono- and bifocal VIN 2-3 showed complete clearance. However, a complete response could be achieved in only 4 (27%) of 15 women with multifocal VIN 2-3, whereas a partial response was noted in 9 of these patients with a total of 70 lesions, out of which 44 (63%) lesions disappeared. No response was seen in 2 patients with multifocal VIN 3. Histological assessment of the fluorescence-directed biopsies revealed that increased pigmentation and hyperkeratosis of the lesions were associated with low response rates. PDT using 5-ALA represents an alternative treatment modality for VIN which is easy to perform and has the advantage of minimal tissue destruction, low side effects and excellent cosmetic results. However, multifocal VIN disease with pigmented and hyperkeratinic lesions remains difficult to treat. Copyright 2000 Wiley-Liss, Inc.
Multifocal tuberculous osteomyelitis in a 3-year-old child.
Dewan, Pooja; Tandon, Anupama; Rohatgi, Smriti; Qureshi, Shuaib
2017-05-01
Multifocal skeletal tuberculosis accounts for less than 1% of all tuberculous lesions in children. A 3-year-old unimmunised child presented with painless symmetrical swelling of both arms, pallor and hepatosplenomegaly. A skeletal survey demonstrated lytic lesions of the metadiaphysis of both humeri, a rib and the sacrum. The possibility of Langerhans cell histiocytosis or multifocal fibrous dysplasia was considered; however, acid-fast bacilli were detected in the biopsy specimen and real-time polymerase chain reaction confirmed Mycobacterium tuberculosis infection. Culture for M. tuberculosis was negative. The patient responded to anti-tuberculous therapy.
Features of optical surfaces of multifocal diffractive-refractive eye lenses
NASA Astrophysics Data System (ADS)
Lenkova, G. A.
2017-09-01
This paper considers shape features of the surface structures of multifocal intraocular lenses (IOLs), which, unlike bifocal IOLs, generate additional foci or extends the depth of focus, which not only corrects near and far vision but also provides good vision at intermediate distances. Expansion of the field of clear vision is achieved due to the effects of diffraction, interference, and refraction (change in the radius of curvature of the lens surface). The optical characteristics of the most famous multifocal IOLs (trifocal and quadrafocal lenses and lenses with extended focal area) are given.
Park, F J; Jaensch, S
2009-01-01
A nestling Derbyan parrot (Psittacula derbiana) was presented with unusual subcutaneous swellings of the thigh regions, and poor growth. Histological examination revealed actinomycetous bacteria associated with multifocal systemic granulomas. The clinical and pathological findings of the case are presented, and some relevant aspects of actinomycetous bacterial infections in mammals and birds are discussed. Although granulomatous disease is encountered at times in avian species, the actinomycetous bacteria (Nocardia and Actinomyces spp.) have rarely been reported in association with multifocal granulomatous disease in birds.
NASA Astrophysics Data System (ADS)
Matsumoto, Naoya; Okazaki, Shigetoshi; Takamoto, Hisayoshi; Inoue, Takashi; Terakawa, Susumu
2014-02-01
We propose a method for high precision modulation of the pupil function of a microscope objective lens to improve the performance of multifocal multi-photon microscopy (MMM). To modulate the pupil function, we adopt a spatial light modulator (SLM) and place it at the conjugate position of the objective lens. The SLM can generate an arbitrary number of spots to excite the multiple fluorescence spots (MFS) at the desired positions and intensities by applying an appropriate computer-generated hologram (CGH). This flexibility allows us to control the MFS according to the photobleaching level of a fluorescent protein and phototoxicity of a specimen. However, when a large number of excitation spots are generated, the intensity distribution of the MFS is significantly different from the one originally designed due to misalignment of the optical setup and characteristics of the SLM. As a result, the image of a specimen obtained using laser scanning for the MFS has block noise segments because the SLM could not generate a uniform MFS. To improve the intensity distribution of the MFS, we adaptively redesigned the CGH based on the observed MFS. We experimentally demonstrate an improvement in the uniformity of a 10 × 10 MFS grid using a dye solution. The simplicity of the proposed method will allow it to be applied for calibration of MMM before observing living tissue. After the MMM calibration, we performed laser scanning with two-photon excitation to observe a real specimen without detecting block noise segments.
Kanadani, Fabio N; Mello, Paulo AA; Dorairaj, Syril K; Kanadani, Tereza CM
2014-01-01
Introduction The gold standard in functional glaucoma evaluation is standard automated perimetry (SAP). However, SAP depends on the reliability of the patients’ responses and other external factors; therefore, other technologies have been developed for earlier detection of visual field changes in glaucoma patients. The frequency-doubling perimetry (FDT) is believed to detect glaucoma earlier than SAP. The multifocal visual evoked potential (mfVEP) is an objective test for functional evaluation. Objective To evaluate the sensitivity and specificity of FDT and mfVEP tests in normal, suspect, and glaucomatous eyes and compare the monocular and interocular mfVEP. Methods Ninety-five eyes from 95 individuals (23 controls, 33 glaucoma suspects, 39 glaucomatous) were enrolled. All participants underwent a full ophthalmic examination, followed by SAP, FDT, and mfVEP tests. Results The area under the curve for mean deviation and pattern standard deviation were 0.756 and 0.761, respectively, for FDT, 0.564 and 0.512 for signal and alpha for interocular mfVEP, and 0.568 and 0.538 for signal and alpha for monocular mfVEP. This difference between monocular and interocular mfVEP was not significant. Conclusion The FDT Matrix was superior to mfVEP in glaucoma detection. The difference between monocular and interocular mfVEP in the diagnosis of glaucoma was not significant. PMID:25075173
Lehmann, Robert; Modi, Satish; Fisher, Bret; Michna, Magda; Snyder, Michael
2017-01-01
The purpose of this study was to evaluate the clinical outcomes of apodized diffractive +3.0 D multifocal toric intraocular lens (IOL) implantations in subjects with preoperative corneal astigmatism. This was a prospective cohort study conducted at 21 US sites. The study population consisted of 574 subjects, aged ≥21 years, with preoperative astigmatism 0.75-2.82 D, and potential postoperative visual acuity (VA) ≥0.2 logMAR, undergoing bilateral cataract removal by phacoemulsification. The intervention was bilateral implantation of aspheric apodized diffractive +3.0 D multifocal toric or spherical multifocal nontoric IOLs. The main outcome measures were monocular uncorrected near and distance VA and safety at 12 months. A total of 373/386 and 182/188 subjects implanted with multifocal toric and nontoric IOLs, respectively, completed 12-month follow-up after the second implantation. Toric IOLs were nonin-ferior in monocular uncorrected distance (4 m) and near (40 cm) VA but had >1 line better binocular uncorrected intermediate VA (50, 60, and 70 cm) than nontoric IOLs. Toric IOLs reduced cylinder to within 0.50 D and 1.0 D of target in 278 (74.5%) and 351 (94.1%) subjects, respectively. Mean ± standard deviation (SD) differences between intended and achieved axis orientation in the first and second implanted eyes were 5.0°±6.1° and 4.7°±4.0°, respectively. Mean ± SD 12-month IOL rotations in the first and second implanted eyes were 2.7°±5.8° and 2.2°±2.7°, respectively. No subject receiving toric IOLs required secondary surgical intervention due to optical lens properties. Multifocal toric IOLs were noninferior to multifocal nontoric IOLs in uncorrected distance and near VAs in subjects with preexisting corneal astigmatism and effectively corrected astigmatism of 0.75-2.82 D.
Shao, Tiffany; Yousef, Peter; Shipilova, Irina; Saleeb, Rola; Lee, Jason Y; Krizova, Adriana
2016-03-01
Multifocal renal cell carcinoma of different histological subtypes within a single kidney is rare. We report a recently classified clear cell (tubulo) papillary renal cell carcinoma as part of an unusual case of multifocal renal cell carcinoma of discordant histological subtypes. A 57 year-old-man was found to have multiple renal tumors and cysts on imaging and underwent a laparoscopic left radical nephrectomy. Pathological review showed multifocal renal cell carcinoma (clear cell (tubulo) papillary, clear cell and papillary renal cell carcinomas and papillary adenomas). Morphology of clear cell papillary renal cell carcinoma was supported by immunohistochemical profile (CK7+, HMWK+, CAIX+, AMACR-, CD10-, TFE3-). This is the first report of clear cell papillary renal cell carcinoma as part of multifocal renal cell carcinoma of different histological subtypes. Related lineage of clear cell renal cell carcinoma and papillary renal cell carcinoma is supported by the highest prevalence of their combination within multifocal renal cell carcinoma of different histological subtypes along with their molecular interconnection. Clear cell papillary renal cell carcinoma may be uniquely placed between clear cell and papillary renal cell carcinomas since it shows morphological features intermediate between clear cell and papillary renal cell carcinoma along with overlapping but unique immunohistochemical profile. Clear cell papillary renal cell carcinoma may be molecularly related to clear cell and papillary renal cell carcinomas since the tumors overexpress markers of HIF pathway activation with normal/elevated VHL mRNA expression and some tumors show losses of chromosome 3. Due to the overlapping morphology, it is possible that cases of clear cell papillary renal cell carcinoma may have been misclassified as papillary or clear cell renal cell carcinoma in the literature, incorrectly increasing their reported prevalence. Identification of multifocal RCCs may be related to the extent of pathological sampling. Copyright © 2016 Elsevier GmbH. All rights reserved.
Magnetic Resonance Enterography to Assess Multifocal and Multicentric Bowel Endometriosis.
Nyangoh Timoh, Krystel; Stewart, Zelda; Benjoar, Mikhael; Beldjord, Selma; Ballester, Marcos; Bazot, Marc; Thomassin-Naggara, Isabelle; Darai, Emile
To prospectively determine the accuracy of magnetic resonance enterography (MRE) compared with conventional magnetic resonance imaging (MRI) for multifocal (i.e., multiple lesions affecting the same digestive segment) and multicentric (i.e., multiple lesions affecting several digestive segments) bowel endometriosis. A prospective study (Canadian Task Force classification II-2). Tenon University Hospital, Paris, France. Patients with MRI-suspected colorectal endometriosis scheduled for colorectal resection from April 2014 to February 2016 were included. Patients underwent both 1.5-Tesla MRI and MRE as well as laparoscopically assisted and open colorectal resections. The diagnostic performance of MRI and MRE was evaluated for sensitivity, specificity, positive and negative predictive values, accuracy, and positive and negative likelihood ratios (LRs). The interobserver variability of the experienced and junior radiologists was quantified using weighted statistics. Forty-seven patients were included. Twenty-two (46.8%) patients had unifocal lesions, 14 (30%) had multifocal lesions, and 11 (23.4%) had multicentric lesions. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multifocal lesions were 0.29 (6/21), 1.00 (23/24), 15.36, and 0.71 for MRI and 0.57 (12/21), 0.89 (23/25), 4.95, and 0.58 for MRE. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multicentric lesions were 0.18 (1/11), 1.00 (1/1), 15, and 0.80 for MRI and 0.46 (5/11), 0.92 (33/36), 5.45, and 0.60 for MRE. Lower accuracies for MRI compared with MRE to diagnose multicentric (p = .01) and multifocal lesions (p = .004) were noted. The interobserver agreement for MRE was good for both multifocality (κ = 0.80) and multicentricity (κ = 0.61). MRE has better accuracy for diagnosing multifocal and multicentric bowel endometriosis than conventional MRI. Copyright © 2018. Published by Elsevier Inc.
Multifocal tenosynovial giant cell tumors in a child with Noonan syndrome.
Meyers, Arthur B; Awomolo, Agboola O; Szabo, Sara
2017-03-01
Noonan syndrome is a genetic disorder with variable expression of distinctive facial features, webbed neck, chest deformity, short stature, cryptorchidism and congenital heart disease. The association of Noonan syndrome and giant cell granulomas of the mandible is widely reported. However, Noonan syndrome may also be associated with single or multifocal tenosynovial giant cell tumors, also referred to as pigmented villonodular synovitis. We report a child with Noonan syndrome, giant cell granulomas of the mandible and synovial and tenosynovial giant cell tumors involving multiple joints and tendon sheaths who was initially misdiagnosed with juvenile idiopathic arthritis. It is important for radiologists to be aware of the association of Noonan syndrome and multifocal giant cell lesions, which can range from the more commonly described giant cell granulomas of the mandible to isolated or multifocal intra- or extra-articular tenosynovial giant cell tumors or a combination of all of these lesions.
Refractive outcomes after multifocal intraocular lens exchange.
Kim, Eric J; Sajjad, Ahmar; Montes de Oca, Ildamaris; Koch, Douglas D; Wang, Li; Weikert, Mitchell P; Al-Mohtaseb, Zaina N
2017-06-01
To evaluate the refractive outcomes after multifocal intraocular lens (IOL) exchange. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. Patients had multifocal IOL explantation followed by IOL implantation. Outcome measures included type of IOL, surgical indication, corrected distance visual acuity (CDVA), and refractive prediction error. The study comprised 29 patients (35 eyes). The types of IOLs implanted after multifocal IOL explantation included in-the-bag IOLs (74%), iris-sutured IOLs (6%), sulcus-fixated IOLs with optic capture (9%), sulcus-fixated IOLs without optic capture (9%), and anterior chamber IOLs (3%). The surgical indication for exchange included blurred vision (60%), photic phenomena (57%), photophobia (9%), loss of contrast sensitivity (3%), and multiple complaints (29%). The CDVA was 20/40 or better in 94% of eyes before the exchange and 100% of eyes after the exchange (P = .12). The mean refractive prediction error significantly decreased from 0.22 ± 0.81 diopter (D) before the exchange to -0.09 ± 0.53 D after the exchange (P < .05). The median absolute refractive prediction error significantly decreased from 0.43 D before the exchange to 0.23 D after the exchange (P < .05). Multifocal IOL exchange can be performed safely with good visual outcomes using different types of IOLs. A lower refractive prediction error and a higher likelihood of 20/40 or better vision can be achieved with the implantation of the second IOL compared with the original multifocal IOL, regardless of the final IOL position. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Agresta, Blaise; Knorz, Michael C; Kohnen, Thomas; Donatti, Christina; Jackson, Daniel
2012-06-01
To evaluate uncorrected distance visual acuity (UDVA) as well as uncorrected near visual acuity (UNVA) as outcomes in treating presbyopic cataract patients to assist clinicians and ophthalmologists in their decision-making process regarding available interventions. Medline, Embase, and Evidence Based Medicine Reviews were systematically reviewed to identify studies reporting changes in UDVA and UNVA after cataract surgery in presbyopic patients. Strict inclusion/exclusion criteria were used to exclude any studies not reporting uncorrected visual acuity in a presbyopic population with cataracts implanted with multifocal intraocular lenses (IOLs). Relevant outcomes (UDVA and UNVA) were identified from the studies retrieved through the systematic review process. Twenty-nine studies were identified that reported uncorrected visual acuities, including one study that reported uncorrected intermediate visual acuity. Nine brands of multifocal IOLs were identified in the search. All studies identified in the literature search reported improvements in UDVA and UNVA following multifocal IOL implantation. The largest improvements in visual acuity were reported using the Rayner M-Flex lens (Rayner Intraocular Lenses Ltd) (UDVA, binocular: 1.05 logMAR, monocular: 0.92 logMAR; UNVA, binocular and monocular: 0.83 logMAR) and the smallest improvements were reported using the Acri.LISA lens (Carl Zeiss Meditec) (UDVA, 0.21 decimal; UNVA, 0.51 decimal). The results of this systematic review show the aggregate of studies reporting a beneficial increase in UDVA and UNVA with the use of multifocal IOLs in cataract patients with presbyopia, hence providing evidence to support the hypothesis that multifocal IOLs increase UDVA and UNVA in cataract patients. Copyright 2012, SLACK Incorporated.
Power profiles of single vision and multifocal soft contact lenses.
Wagner, Sandra; Conrad, Fabian; Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Holden, Brien A
2015-02-01
The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression. The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated. Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality. Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Evaluation of loss in optical quality of multifocal intraocular lenses with glistenings.
DeHoog, Edward; Doraiswamy, Anand
2016-04-01
To study the impact of loss in optical quality from glistenings in diffractive multifocal intraocular lenses (IOLs) using ray tracing in a model eye. Independent research laboratory, Irvine, California, USA. Experimental study. A pseudophakic eye model was constructed in Zemax, an optical ray-tracing program, using the Arizona eye model as the basis. The Mie scattering theory was used to describe the intensity and direction of light as it scattered for a spherical particle immersed in a diffractive multifocal IOL. To evaluate the impact of glistening scatter, a more advanced eye model was constructed in Fred, a nonsequential optical ray-tracing software. An evaluation of scatter and modulation transfer function (MTF) was performed for a hydrophobic biomaterial with a refractive index of 1.54 for various sizes and densities of glistenings under mesopic conditions. As predicted by the Mie theory, the amount of scatter was a function of the change in the refractive index, size of the scatterer, and volume fraction of the scatterers. This modeling showed that an increase in density of glistenings can lead to a significant drop of MTF of the IOL. This effect was more pronounced in multifocal IOLs than in monofocal IOLs. Mathematical modeling showed that glistenings in multifocal IOLs lead to a reduction in MTF of the IOL and the pseudophakic eye. The relative loss of MTF in multifocal IOLs was more significant than in monofocal IOLs because of the nature of the design. Drs. DeHoog and Doraiswamy are consultants to Advanced Vision Science, Inc. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
2012-10-24
Coats' Disease; Idiopathic Retinal Telangiectasia; Retinal Angiomatous Proliferation; Polypoidal Choroidal Vasculopathy; Pseudoxanthoma Elasticum; Pathological Myopia; Multi-focal Choroiditis; Rubeosis Iridis; Von Hippel Lindau Disease; BEST VITELLIFORM MACULAR DYSTROPHY, MULTIFOCAL (Disorder)
Multifocal meningiomas in a patient with a constitutional ring chromosome 22.
Arinami, T; Kondo, I; Hamaguchi, H; Nakajima, S
1986-01-01
We report a patient with a constitutional ring chromosome 22, in whom multifocal meningiomas were confirmed at necropsy, and discuss the relationship between the constitutional chromosome change and tumourigenesis of meningiomas in this patient. Images PMID:3712397
Multifocal multi-site Warthin tumour.
Hilton, Jennifer M; Phillips, John S; Hellquist, Henrik B; Premachandra, Don J
2008-12-01
The unique case of a 55-year-old man with multifocal adenolymphoma (Warthin's tumour) of both parotid glands, the neck and post-nasal space is presented. Warthin tumour is almost exclusively a parotid tumour but is known to be bilateral in 7-10% of cases and multifocal in 2% of cases. Most extraglandular Warthin tumours have been located in neck lymph nodes and only a few cases have been reported from other sites. The presented case is unique in having synchronous and metachronous Warthin tumours, as well as one of the tumours being neither truly parotid, nor within a lymph node.
Effect of Nd:YAG laser capsulotomy on refraction in multifocal apodized diffractive pseudophakia.
Vrijman, Violette; van der Linden, Jan Willem; Nieuwendaal, Carla P; van der Meulen, Ivanka J E; Mourits, Maarten P; Lapid-Gortzak, Ruth
2012-08-01
To evaluate the effect on refraction of neodymium:YAG (Nd:YAG) laser posterior capsulotomy for posterior capsule opacification (PCO), and to evaluate the correlation between automated and subjective refraction in multifocal apodized diffractive pseudophakia. A retrospective study of 75 pseudophakic eyes (50 patients) with multifocal apodized diffractive pseudophakia, treated for PCO with Nd:YAG laser posterior capsulotomy, was performed. Pre- and postintervention values of refractive and visual parameters were compared. The outcomes of autorefraction and subjective refraction were also compared. Uncorrected and corrected distance visual acuity improved significantly after Nd:YAG capsulotomy (P<.001). No significant changes were noted in defocus equivalent, astigmatic power vectors J(0) and J(45), and overall blurring strength in subjective refraction and autorefraction. Spherical equivalent changed significantly in autorefraction (P=.008), but not in subjective refraction. Autorefraction and subjective refraction were highly correlated in spherical equivalent, defocus equivalent, and blurring strength (r(2)>0.59). In approximately 7% of eyes, a change of more than 0.50 diopters in spherical equivalent in subjective refraction occurred. In most cases, Nd:YAG laser capsulotomy in patients with multifocal pseudophakia did not result in a change in refraction. However, 7% of eyes experienced a significant change in subjective refraction. Autorefraction correlated well with subjective refraction in apodized diffractive multifocal IOLs. Copyright 2012, SLACK Incorporated.
2005-09-01
34Assessment of local retinal function in patients with retinitis pigmentosa using the multi-focal ERG technique.," Vision Research, vol. 38, pp. 163-179... pigmentosa , and retinal detachment10. mfERG response characteristics have been shown to vary depending on the part of the retina that is affected by a...expanding. Thus, the potential for laser eye injury and retinal damage is increasing. Sensitive and accurate methods to evaluate and follow laser retinal
A method for quantitative analysis of clump thickness in cervical cytology slides.
Fan, Yilun; Bradley, Andrew P
2016-01-01
Knowledge of the spatial distribution and thickness of cytology specimens is critical to the development of digital slide acquisition techniques that minimise both scan times and image file size. In this paper, we evaluate a novel method to achieve this goal utilising an exhaustive high-resolution scan, an over-complete wavelet transform across multi-focal planes and a clump segmentation of all cellular materials on the slide. The method is demonstrated with a quantitative analysis of ten normal, but difficult to scan Pap stained, Thin-prep, cervical cytology slides. We show that with this method the top and bottom of the specimen can be estimated to an accuracy of 1 μm in 88% and 97% of the fields of view respectively. Overall, cellular material can be over 30 μm thick and the distribution of cells is skewed towards the cover-slip (top of the slide). However, the median clump thickness is 10 μm and only 31% of clumps contain more than three nuclei. Therefore, by finding a focal map of the specimen the number of 1 μm spaced focal planes that are required to be scanned to acquire 95% of the in-focus material can be reduced from 25.4 to 21.4 on average. In addition, we show that by considering the thickness of the specimen, an improved focal map can be produced which further reduces the required number of 1 μm spaced focal planes to 18.6. This has the potential to reduce scan times and raw image data by over 25%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Inoue, Makoto; Noda, Toru; Ohnuma, Kazuhiko; Bissen-Miyajima, Hiroko; Hirakata, Akito
2011-11-01
To determine the quality of the image of a grating target placed in the vitreous of isolated pig eyes and photographed through implanted refractive and diffractive multifocal intraocular lenses (IOL). Refractive multifocal (NXG1, PY60MV), diffractive multifocal (ZM900, SA60D3) and monofocal (SA60AT, ZA9003) IOL were implanted in the capsular bag of isolated pig eyes. A grating target was placed in the vitreous and photographed through a flat or a wide-field viewing contact lens. The contrast of the grating targets of different spatial frequencies was measured. With the flat corneal contact lens, the gratings appeared clear and not distorted when viewed through the optics of the NXG1 and PY60MV for far vision but were distorted with reduced contrast when viewed through the optical zone for near vision. The images through the diffractive zone of the ZM900 and SA60D3 were more defocused than with the monofocal IOL (p < 0.005). Ghost images oriented centrifugally of the original image were seen with the ZM900 resulting in lower contrast at higher spatial frequencies than with the SA60D3 with less defocused images only in the central area. With the wide-field viewing contact lens, the images were less defocused and the contrast was comparable to both refractive and diffractive multifocal IOL. Both refractive and diffractive multifocal IOL reduced the contrast of the retinal image when viewed through a flat corneal contact lens but less defocused when viewed through a wide-field viewing contact lens. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
García-Lázaro, Santiago; Ferrer-Blasco, Teresa; Madrid-Costa, David; Albarrán-Diego, César; Montés-Micó, Robert
2015-01-01
To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare. In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; Bausch & Lomb], Acuvue Oasys for Presbyopia [AOP; Johnson & Johnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wearing, each subject's binocular distance visual acuity (BDVA) and binocular distance contrast sensitivity (BDCS) were measured using the Functional Visual Analyzer (Stereo Optical Co., Inc.) under mesopic conditions (3 candela [cd]/m) both with no glare and under the 2 levels of induced glare: 1.0 lux (glare 1) and 28 lux (glare 2). Among the SIMCLs, in terms of BDVA, AOAM and PM outperformed BM and AOP. All contact lenses performed better at level without glare, followed by Glare 1, and with the worst results obtained under glare 2. Binocular distance contrast sensitivity revealed statistically significant differences for 12 cycles per degree (cpd). Among the SIMCLs, post hoc multiple comparison testing revealed that AOAM and PM provided the best BDCS at the three luminance levels. In both cases, BDVA and BDCS at 12 cpd, monofocal contact lenses outperformed all SIMCL ones at all lighting conditions. Air Optix Aqua Multifocal and PM provided better visual performance than BM and AOP for distance vision with low addition and under dim conditions, but they all provide worse performance than monofocal contact lenses.
Sousa, Rafael M; Oyamada, Maria K; Cunha, Leonardo P; Monteiro, Mário L R
2017-09-01
To verify whether multifocal visual evoked potential (mfVEP) can differentiate eyes with temporal hemianopia due to chiasmal compression from healthy controls. To assess the relationship between mfVEP, standard automated perimetry (SAP), and Fourier domain-optical coherence tomography (FD-OCT) macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Twenty-seven eyes with permanent temporal visual field (VF) defects from chiasmal compression on SAP and 43 eyes of healthy controls were submitted to mfVEP and FD-OCT scanning. Multifocal visual evoked potential was elicited using a stimulus pattern of 60 sectors and the responses were averaged for the four quadrants and two hemifields. Optical coherence tomography macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in four sectors around the disc. Visual field loss was estimated in four quadrants and each half of the 24-2 strategy test points. Multifocal visual evoked potential measurements in the two groups were compared using generalized estimated equations, and the correlations between mfVEP, VF, and OCT findings were quantified. Multifocal visual evoked potential-measured temporal P1 and N2 amplitudes were significantly smaller in patients than in controls. No significant difference in amplitude was observed for nasal parameters. A significant correlation was found between mfVEP amplitudes and temporal VF loss, and between mfVEP amplitudes and the corresponding OCT-measured macular and RNFL thickness parameters. Multifocal visual evoked potential amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significantly correlated with VF and OCT findings, suggesting mfVEP is a useful tool for the detection of visual abnormalities in patients with chiasmal compression.
Aung, Ar Kar; Teh, Bing Mei; McGrath, Christopher; Thompson, Philip J
2013-07-01
Pulmonary infections by Sporothrix spp. manifest radiologically as cavitary or non-cavitary disease depending on whether the infection is primary pulmonary or multifocal sporotrichosis. Despite current guidelines, the optimal management for pulmonary sporotrichosis remains unclear. In order to clarify this, we present two cases of pulmonary sporotrichosis, as well as the results of a comprehensive literature review of treatment outcomes based on clinico-radiological presentation patterns of the disease. A literature search of all case reports in English language over the last 50 years (1960-2010) was conducted. Data on patient characteristics, risk factors, clinico-radiological patterns, treatment modalities and outcomes were collected and analyzed. A total of 86 cases were identified, i.e., 64 (74.4%) primary pulmonary and 22 (25.6%) multifocal sporotrichosis. Radiologically, primary pulmonary disease was commonly characterized by cavity formation which was lacking in multifocal infections (P = 0.0001). Immunosuppressant use was more common in multifocal sporotrichosis (P = 0.0001), while hemoptysis was more common in primary pulmonary form (P = 0.01). No other differences in patient characteristics or risk factors were noted. Extra-pulmonary multifocal sporotrichosis most commonly involved skin (81.8%) and joints (45.4%). For patients with cavitary primary pulmonary sporotrichosis, outcomes from medical therapy alone were inferior to surgical intervention (P = 0.02). However, for both primary pulmonary and multifocal sporotrichosis with non-cavitary disease, medical therapy alone provided good outcomes. Only 12 (16.7%) cases were treated with itraconazole. Treatment of pulmonary sporotrichosis should be guided by the clinico-radiological patterns of presentation. Medical therapy alone is likely sufficient for non-cavitary disease while early surgery should be considered for cavitary primary pulmonary sporotrichosis. The experience in treating cavitary disease with itraconazole alone is limited and further data are required.
Comparative visual performance with monofocal and multifocal intraocular lenses
Gundersen, Kjell Gunnar; Potvin, Richard
2013-01-01
Background To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted. Methods Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a single diagnostic visit between 3 and 8 months after second-eye surgery. Lenses tested included an aspheric monofocal and two apodized diffractive multifocal IOLs with slightly different design parameters. A total of 94 patients were evaluated. Results Subjects with the ReSTOR® +2.5 D IOL had better near and intermediate vision than those subjects with a monofocal IOL. Intermediate vision was similar to, and near vision slightly lower than, that of subjects with a ReSTOR® +3.0 D IOL implanted. The preferred reading distance was slightly farther out for the +2.5 D relative to the +3.0 D lens, and farthest for the monofocal. Visual acuity at the preferred reading distance was equal with the two multifocal IOLs and significantly worse with the monofocal IOL. Quality of vision measures were highest with the monofocal IOL and similar between the two multifocal IOLs. Conclusion The data indicate that the ReSTOR +2.5 D IOL provided good intermediate and functional near vision for patients who did not want to accept a higher potential for visual disturbances associated with the ReSTOR +3.0 D IOL, but wanted more near vision than a monofocal IOL generally provides. Quality of vision was not significantly different between the multifocal IOLs, but patient self-selection for each lens type may have been a factor. PMID:24143064
[Multifocal intraocular lenses. A review].
Auffarth, G U; Dick, H B
2001-02-01
Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of that time MIOL decentration and surgically induced astigmatism were possible complications. In addition reduced contrast sensitivity and increased glare were common problems of MIOL because of their optical principles. New developments in this field in recent years such as the multizonal, progressive refractive MIOL in combination with improved surgical techniques have overcome those initial problems. Therefore, modern multifocal IOLs can be considered not only for correction of aphakia but also for refractive purposes.
Vu, Lien T; Chen, Chao-Chang A; Yu, Chia-Wei
2018-02-05
This study aims to develop a new optical design method of soft multifocal contact lens (CLs) to obtain uniform optical power in large center-distance zone with optimized Non-Uniform Rational B-spline (NURBS). For the anterior surface profiles of CLs, the NURBS design curves are optimized to match given optical power distributions. Then, the NURBS in the center-distance zones are fitted in the corresponding spherical/aspheric curves for both data points and their centers of curvature to achieve the uniform power. Four cases of soft CLs have been manufactured by casting in shell molds by injection molding and then measured to verify the design specifications. Results of power profiles of these CLs are concord with the given clinical requirements of uniform powers in larger center-distance zone. The developed optical design method has been verified for multifocal CLs design and can be further applied for production of soft multifocal CLs.
N-3 Polyunsaturated Fatty Acids of Marine Origin and Multifocality in Human Breast Cancer.
Ouldamer, Lobna; Goupille, Caroline; Vildé, Anne; Arbion, Flavie; Body, Gilles; Chevalier, Stephan; Cottier, Jean Philippe; Bougnoux, Philippe
2016-01-01
The microenvironment of breast epithelial tissue may contribute to the clinical expression of breast cancer. Breast epithelial tissue, whether healthy or tumoral, is directly in contact with fat cells, which in turn could influence tumor multifocality. In this pilot study we investigated whether the fatty acid composition of breast adipose tissue differed according to breast cancer focality. Twenty-three consecutive women presenting with non-metastatic breast cancer underwent breast-imaging procedures including Magnetic Resonance Imaging prior to treatment. Breast adipose tissue specimens were collected during breast surgery. We established a biochemical profile of adipose tissue fatty acids by gas chromatography. We assessed whether there were differences according to breast cancer focality. We found that decreased levels in breast adipose tissue of docosahexaenoic and eicosapentaenoic acids, the two main polyunsaturated n-3 fatty acids of marine origin, were associated with multifocality. These differences in lipid content may contribute to mechanisms through which peritumoral adipose tissue fuels breast cancer multifocality.
[The Clinical and Molecular Characteristics of Adenocarcinoma Presented by Multi-focal GGO].
Song, Yang; Liang, Naixin; Li, Shanqing
2018-03-20
Due to emphasis on early screening for lung cancer, the detection rate of multiple ground glass opacities (GGOs) on computed tomography (CT) image increases in recent years, and research on multifocal adenocarcinomas presented by GGOs has been thriving. It is more common in women and non-smokers and has excellent prognosis both in patients with natural history and after surgery. These clinical features suggest that it is likely to be a distinct disease entity. From the perspective of molecular genetics, lesions in the same individual are likely to have distinct clonal features. Therefore, genetic heterogeneity is the most prominent feature of multifocal pulmonary adenocarcinomas with GGOs. The genetic heterogeneity is expected to assist the diagnosis of multifocal pulmonary adenocarcinoma and intrapulmonary metastasis, and also suggests that genetic testing of the GGO lesions is of great therapeutic significance. Some GGO lesions may harvest the similar clonal feature, which provide new evidence for the theory of spread through air spaces (STAS). .
Highly uniform parallel microfabrication using a large numerical aperture system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Zi-Yu; Su, Ya-Hui, E-mail: ustcsyh@ahu.edu.cn, E-mail: dongwu@ustc.edu.cn; Zhang, Chen-Chu
In this letter, we report an improved algorithm to produce accurate phase patterns for generating highly uniform diffraction-limited multifocal arrays in a large numerical aperture objective system. It is shown that based on the original diffraction integral, the uniformity of the diffraction-limited focal arrays can be improved from ∼75% to >97%, owing to the critical consideration of the aperture function and apodization effect associated with a large numerical aperture objective. The experimental results, e.g., 3 × 3 arrays of square and triangle, seven microlens arrays with high uniformity, further verify the advantage of the improved algorithm. This algorithm enables the laser parallelmore » processing technology to realize uniform microstructures and functional devices in the microfabrication system with a large numerical aperture objective.« less
Accommodation and Phoria in Children Wearing Multifocal Contact Lenses
Gong, Celia R; Troilo, David; Richdale, Kathryn
2017-01-01
Purpose To determine the effect of multifocal contact lenses on accommodation and phoria in children. Methods This was a prospective, non-dispensing, randomized, crossover, single visit study. Myopic children with normal accommodation and binocularity and no history of myopia control treatment were enrolled and fitted with Coopervision Biofinity single vision (SV) and multifocal (MF, +2.50D center distance add) contact lenses. Accommodative responses (photorefraction) and phorias (Modified Thorington) were measured at 4 distances (>3m, 100cm, 40cm, 25cm). Secondary measures included high and low contrast logMAR acuity, accommodative amplitude and facility. Differences between contact lens designs were analyzed using repeated measures regression and paired t-tests. Results A total of 16 subjects, aged 10-15 years, completed the study. There was a small decrease in high (SV: -0.08, MF: +0.01) and low illumination (SV:-0.03, MF: +0.08) (both p<0.01) visual acuity, and contrast sensitivity (SV: 2.0, MF: 1.9 log units, p=0.015) with multifocals. Subjects were more exophoric at 40 cm (SV: -0.41, MF: -2.06 Δ) and 25cm (SV: -0.83, MF: -4.30 Δ) (both p<0.01). With multifocals, subjects had decreased accommodative responses at distance (SV: -0.04; MF: -0.37 D, p=0.02), 100 cm (SV: +0.37; MF: -0.35 D, p<0.01), 40 cm (SV: +1.82; MF: +0.62 D, p<0.01), and 25 cm (SV: +3.38; MF: +1.75 D, p<0.01). There were no significant differences in accommodative amplitude (p=0.66) or facility (p=0.54). Conclusions Children wearing multifocal contact lenses exhibited reduced accommodative responses and more exophoria at increasingly higher accommodative demands than with single vision contact lenses. This suggests that children may be relaxing their accommodation and using the positive addition or increased depth of focus from added spherical aberration of the multifocals. Further studies are needed to evaluate other lens designs, different amounts of positive addition and aberrations, and long-term adaptation to lenses. PMID:28027276
Processes for manufacturing multifocal diffractive-refractive intraocular lenses
NASA Astrophysics Data System (ADS)
Iskakov, I. A.
2017-09-01
Manufacturing methods and design features of modern diffractive-refractive intraocular lenses are discussed. The implantation of multifocal intraocular lenses is the most optimal method of restoring the accommodative ability of the eye after removal of the natural lens. Diffractive-refractive intraocular lenses are the most widely used implantable multifocal lenses worldwide. Existing methods for manufacturing such lenses implement various design solutions to provide the best vision function after surgery. The wide variety of available diffractive-refractive intraocular lens designs reflects the demand for this method of vision correction in clinical practice and the importance of further applied research and development of new technologies for designing improved lens models.
Comparison of vision through surface modulated and spatial light modulated multifocal optics.
Vinas, Maria; Dorronsoro, Carlos; Radhakrishnan, Aiswaryah; Benedi-Garcia, Clara; LaVilla, Edward Anthony; Schwiegerling, Jim; Marcos, Susana
2017-04-01
Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near.
Comparison of vision through surface modulated and spatial light modulated multifocal optics
Vinas, Maria; Dorronsoro, Carlos; Radhakrishnan, Aiswaryah; Benedi-Garcia, Clara; LaVilla, Edward Anthony; Schwiegerling, Jim; Marcos, Susana
2017-01-01
Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near. PMID:28736655
[Multifocal tubulopapillary tumors of the kidney. Morphologic features and prognosis. Three cases].
Abdelmoula, N B; Boudawara, T; Bahloul, A; Hmida, M B; Hachicha, J; Rebai, T; Mhiri, N; Jlidi, R
1999-01-01
Tubulopapillary tumors of the kidney represent a particular group of renal tumors characterized by their less aggressive behavior. These tumors are distinguished from non papillary tumors by their morphologic, cytochemical and genotypic features. They correspond to a continuous spectrum of tumors ranging from papillary renal cell adenoma to papillary renal cell carcinoma. These TTPR show multifocal, bilateral development and chronic lesions of the kidney parenchyma in nearly all cases. The authors report three cases of multifocal TTPR, including one bilateral case. Based on analysis of these cases and a review of the literature, they discuss the histogenetic features and prognosis of TTPR.
Hemkeppler, E; Böhm, M; Kohnen, T
2018-05-29
A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.
Giner, Anna; Aldaba, Mikel; Arjona, Montserrat; Vilaseca, Meritxell; Pujol, Jaume
2015-10-01
To evaluate the usefulness of an infrared open-field autorefractor as a predictor of the refractive error when fitting multifocal contact lenses (MCL). Objective and subjective measurements of the non-cycloplegic distance refractive error were compared in patients wearing MCL. We used the Grand Seiko WAM-5500 autorefractor for the objective measurements. Three commercially available MCL were tested. Twenty-one eyes of sixteen healthy adults were included in the study. Over-refraction was evaluated in terms of spherical equivalent (SE) and astigmatic vectors (J0 and J45). The mean difference±SD of each parameter was calculated. The Kolmogorov-Smirnov test was used to verify the normal distribution. Pearson's correlation, Bland and Altman plot and paired sample t test were used to compare the results obtained with both methods. The mean difference between objective and subjective results of the SE over-refraction was 0.13±0.42D; for astigmatic vectors J0 and J45 were 0.03±0.32D and -0.00±0.17D, respectively. The Kolmogorov-Smirnov test showed a normal distribution for all parameters. The highest Pearson's correlation coefficients were obtained for the SE with values of 0.98 without MCL and 0.97 with MCL. The lowest were obtained for J45 with values of 0.65 without MCL and 0.75 with MCL. Significant correlations were obtained for each parameter. The paired sample t test failed to show significant differences in analyzed parameters except for J0 without MCL. The Grand Seiko WAM-5500 can be used as a screening method of over-refraction in the clinical fitting of MCL. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Effect of multizone refractive multifocal contact lenses on standard automated perimetry.
Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa
2012-09-01
The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.
IOL Tetraflex, KH 3500--presbyopia treatment.
Ferko, J; Ferkova, A
2009-01-01
Presbyopia is a loss of accommodative capacity of the eye determined by age. The possible solutions for its treatment are spectacle correction (mono-, bi- or multifocal), multifocal contact lenses, conductive keratoplasty, excimer laser surgery and surgical solution - CLE. Four-year experience with using LOL Tetraflex KH 3500 by Lenstec. Between 2005 and 2009, 71 eyes of 35 patients with the average age of 52 were operated at the private ophthalmological clinic 3F Microsurgery of the Eye in Kosice. The patients were selected by strict indication criteria recommended by the producer. We have evaluated the ability of the implanted lens to substitute for the presbyopic correction. The subjective criterion of patient's evaluation was the expression of content in common life situations on the scale of 1 to 10. The objective evaluation was constituted by the measurement of the accommodation width, the presence of PCO, its solution by means of YAG capsulotomy and the subsequent influence on the pseudo accommodative capacity of the lense. 92% of operated patients expressed their complete satisfaction with the surgery results. By objective accommodometer measurement, we have identified the average accommodation width of +1,5 dioptres on the operated eyes. The presence of PCO was discovered in 42,2% cases. All cases were treated by YAG Capsulotomy. By further observation we have tried to determine the influence of YAG Capsulotomy on the accommodation width and pseudo accommodative capacity of the eye. The selection and use of TETRAFLEX lens is an appropriate alternative to presbyopia treatment with suitable patients.
Measuring Distances Using Digital Cameras
ERIC Educational Resources Information Center
Kendal, Dave
2007-01-01
This paper presents a generic method of calculating accurate horizontal and vertical object distances from digital images taken with any digital camera and lens combination, where the object plane is parallel to the image plane or tilted in the vertical plane. This method was developed for a project investigating the size, density and spatial…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-03
...-Exclusive Licenses: Multi-Focal Structured Illumination Microscopy Systems and Methods AGENCY: National... pertains to a system and method for digital confocal microscopy that rapidly processes enhanced images. In particular, the invention is a method for digital confocal microscopy that includes a digital mirror device...
Multifocal epithelial hyperplasia: A potentially precancerous disease? (Review)
BASCONES-MARTÍNEZ, A.; COK, S.; BASCONES-ILUNDÁIN, C.; ARIAS-HERRERA, S.; GOMEZ-FONT, R.; BASCONES-ILUNDÁIN, J.
2012-01-01
Multifocal epithelial hyperplasia (MEH), also known as Heck’s disease, manifests as a papulonodular lesion in the oral mucosa and has been associated with the human papillomavirus, a virus related to various precancerous diseases in the oral cavity. It has a predisposition for the female gender and for children. Although the majority of reported cases have been among American Indians and Eskimos, it has been described in multiple ethnic groups in various geographical locations. The objective of this review was to report on the clinical characteristics and epidemiology of MEH and its possible correlation with oral cancer. It is based on a search of articles in international journals published prior to April 2011, using the PubMed database and selecting articles related to the epidemiology and clinical characteristics of MEH. The review revealed a higher number of cases in individuals of American Indian origin and a predilection of the disease for the female gender and for patients between the 1st and 2nd decades of life. The most frequent lesion site was the lower lip. The disease has been associated with socio-economic and genetic factors, among others. No cases of malignant transformation have been reported. PMID:22740890
Gallach Sanchis, David; Doñate Pérez, Francisco; Jiménez Ortega, Plácido
2014-06-01
Chickenpox is an infectious disease common in children, which in most cases is benign toward the self-limited resolution. There are, however, serious systemic and musculoskeletal complications, especially in patients with immunosuppression. We report a case of multifocal skeletal muscle involvement, as a complication of chickenpox by Streptococcus pyogenes.
Kerasnoudis, A; Pitarokoili, K; Gold, R; Yoon, M-S
2015-01-15
The aim of this observational study was to evaluate the applicability of a recently introduced ultrasound score (Bochum ultrasound score; BUS) in distinguishing the chronic inflammatory demyelinating polyneuropathy (CIDP) from the multifocal motor neuropathy (MMN) or the multifocal acquired demyelinating sensory and motor neuropathy (MADSAM). The BUS underwent prospective evaluation of its applicability in a group of 13 patients (mean age 47.2, SD ± 13.7, 9 women), who were referred to our department between January 2012 and August 2013 with the clinical picture of a chronic symmetrical or asymmetrical sensory/sensorimotor neuropathy. The cut-off value of ≥ 2 points in the "Bochum ultrasound score" showed a sensitivity of 80% and specificity of 87.5% (PPV=80%, NPV=87.5%) in distinguishing CIDP from MMN or MADSAM. The BUS seems to allow a reliable distinction of CIDP from multifocal acquired demyelinating polyneuropathies causing predominantly motor nerve dysfunction, such as MMN or MADSAM. Our ultrasound findings indicate a stronger relationship of MADSAM to MMN, than to CIDP. Copyright © 2014 Elsevier B.V. All rights reserved.
Gustafsson, Ola S E; Ekström, Peter; Kröger, Ronald H H
2012-07-01
Crystalline lenses with multiple focal lengths in monochromatic light (multifocal lenses) are present in many vertebrate groups. These lenses compensate for chromatic aberration and create well-focused color images. Stabilization of the lens within the eye and the ability to adjust focus are further requirements for vision in high detail. We investigated the occurrence of multifocal lenses by photorefractometry and lens suspension structures by light and electron microscopy in sturgeons (Acipenseriformes, Chondrostei) as well as sharks and rays (Elasmobranchii, Chondrichthyes). Multifocal lenses were found in two more major vertebrate groups, the Chondrostei represented by Acipenseriformes and Chondrichthyes represented by Elasmobranchii. The lens suspension structures of sturgeons, sharks, and rays are more complex than described previously. The lens is suspended by many delicate suspensory fibers in association with a ventral papilla in all groups studied. The arrangements of the suspensory fibers are most similar between sturgeons and sharks. In rays, the lens is suspended by a smaller ventral papilla and the suspensory fibers are arranged more concentrically to the lens. Copyright © 2012 Wiley Periodicals, Inc.
[Clinical results after implantation of a new segmental refractive multifocal intraocular lens].
Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M
2013-11-01
The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.
Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations
Akondi, Vyas; Dorronsoro, Carlos; Gambra, Enrique; Marcos, Susana
2017-01-01
Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed. PMID:28717577
Visual acuity estimation from simulated images
NASA Astrophysics Data System (ADS)
Duncan, William J.
Simulated images can provide insight into the performance of optical systems, especially those with complicated features. Many modern solutions for presbyopia and cataracts feature sophisticated power geometries or diffractive elements. Some intraocular lenses (IOLs) arrive at multifocality through the use of a diffractive surface and multifocal contact lenses have a radially varying power profile. These type of elements induce simultaneous vision as well as affecting vision much differently than a monofocal ophthalmic appliance. With myriad multifocal ophthalmics available on the market it is difficult to compare or assess performance in ways that effect wearers of such appliances. Here we present software and algorithmic metrics that can be used to qualitatively and quantitatively compare ophthalmic element performance, with specific examples of bifocal intraocular lenses (IOLs) and multifocal contact lenses. We anticipate this study, methods, and results to serve as a starting point for more complex models of vision and visual acuity in a setting where modeling is advantageous. Generating simulated images of real- scene scenarios is useful for patients in assessing vision quality with a certain appliance. Visual acuity estimation can serve as an important tool for manufacturing and design of ophthalmic appliances.
Towards multifocal ultrasonic neural stimulation: pattern generation algorithms
NASA Astrophysics Data System (ADS)
Hertzberg, Yoni; Naor, Omer; Volovick, Alexander; Shoham, Shy
2010-10-01
Focused ultrasound (FUS) waves directed onto neural structures have been shown to dynamically modulate neural activity and excitability, opening up a range of possible systems and applications where the non-invasiveness, safety, mm-range resolution and other characteristics of FUS are advantageous. As in other neuro-stimulation and modulation modalities, the highly distributed and parallel nature of neural systems and neural information processing call for the development of appropriately patterned stimulation strategies which could simultaneously address multiple sites in flexible patterns. Here, we study the generation of sparse multi-focal ultrasonic distributions using phase-only modulation in ultrasonic phased arrays. We analyse the relative performance of an existing algorithm for generating multifocal ultrasonic distributions and new algorithms that we adapt from the field of optical digital holography, and find that generally the weighted Gerchberg-Saxton algorithm leads to overall superior efficiency and uniformity in the focal spots, without significantly increasing the computational burden. By combining phased-array FUS and magnetic-resonance thermometry we experimentally demonstrate the simultaneous generation of tightly focused multifocal distributions in a tissue phantom, a first step towards patterned FUS neuro-modulation systems and devices.
Bette, Stefanie; Barz, Melanie; Huber, Thomas; Straube, Christoph; Schmidt-Graf, Friederike; Combs, Stephanie E; Delbridge, Claire; Gerhardt, Julia; Zimmer, Claus; Meyer, Bernhard; Kirschke, Jan S; Boeckh-Behrens, Tobias; Wiestler, Benedikt; Gempt, Jens
2018-03-14
Recent studies suggested that postoperative hypoxia might trigger invasive tumor growth, resulting in diffuse/multifocal recurrence patterns. Aim of this study was to analyze distinct recurrence patterns and their association to postoperative infarct volume and outcome. 526 consecutive glioblastoma patients were analyzed, of which 129 met our inclusion criteria: initial tumor diagnosis, surgery, postoperative diffusion-weighted imaging and tumor recurrence during follow-up. Distinct patterns of contrast-enhancement at initial diagnosis and at first tumor recurrence (multifocal growth/progression, contact to dura/ventricle, ependymal spread, local/distant recurrence) were recorded by two blinded neuroradiologists. The association of radiological patterns to survival and postoperative infarct volume was analyzed by uni-/multivariate survival analyses and binary logistic regression analysis. With increasing postoperative infarct volume, patients were significantly more likely to develop multifocal recurrence, recurrence with contact to ventricle and contact to dura. Patients with multifocal recurrence (Hazard Ratio (HR) 1.99, P = 0.010) had significantly shorter OS, patients with recurrent tumor with contact to ventricle (HR 1.85, P = 0.036), ependymal spread (HR 2.97, P = 0.004) and distant recurrence (HR 1.75, P = 0.019) significantly shorter post-progression survival in multivariate analyses including well-established prognostic factors like age, Karnofsky Performance Score (KPS), therapy, extent of resection and patterns of primary tumors. Postoperative infarct volume might initiate hypoxia-mediated aggressive tumor growth resulting in multifocal and diffuse recurrence patterns and impaired survival.
Effect of Unifocal versus Multifocal Lenses on Cervical Spine Posture in Patients with Presbyopia.
Abbas, Rami L; Houri, Mohamad T; Rayyan, Mohammad M; Hamada, Hamada Ahmad; Saab, Ibtissam M
2018-04-04
There are many environmental considerations which may or may not lead to the development of faulty cervical mechanics. The design of near vision lenses could contribute to the development of such cervical dysfunction and consequently neck pain. Decision making regarding proper type of lens prescription seems important for presbyopic individuals. To investigate the effect of unifocal and multifocal lenses on cervical posture. Thirty subjects (18 females and 12 males) participated in the study with an age range from 40 to 64 years. Each subject wore consequently both unifocal and multifocal lenses randomly while reading. Then lateral cervical spine X-ray films were taken for each subject during each lens wearing. X-ray films were analyzed with digital software (Autocad software, 2 D) to measure segmental angles of the cervical vertebrae (Occiput/C1, C1/C2, C2/C3, C3/C4, C4/C5, C5/C6, C6/C7, C3/C7, C0/C3, and occiput/C7). Higher significant extension angle in the segments C0/C7, C1/C2, C5/C6, C6/C7, and C3/C7 (p<0.05) during multifocal lenses wearing were observed in contrast with higher flexion angle between C3/C4 and C4/C5 (p<0.05) with unifocal lenses wear. Multifocal lens spectacles produces increased extension in the cervical vertebrae angles when compared with the use of unifocal lenses.
Tseng, William W; Madewell, John E; Wei, Wei; Somaiah, Neeta; Lazar, Alexander J; Ghadimi, Markus P; Hoffman, Aviad; Pisters, Peter W T; Lev, Dina C; Pollock, Raphael E
2014-07-01
Well-differentiated (WD)/dedifferentiated (DD) liposarcoma is the most common soft tissue sarcoma of the retroperitoneum. The frequency of distant metastasis is low and the major burden of disease is locoregional. We sought to define the patterns of locoregional disease to help guide surgical decision making. Data were collected from 247 patients with de novo or recurrent tumors treated at our institution from 1993 to early 2012. The number and location of tumors at both initial presentation and subsequent locoregional recurrence were determined by combined analysis of operative dictations and radiologic imaging. Thirty-four percent of patients had multifocal locoregional disease (two or more tumors) at initial presentation to our institution, including 9 % who had tumors at synchronous remote retroperitoneal sites. The impact of multifocal disease on overall survival was dependent on histologic subtype (WD vs. DD) and disease presentation (de novo vs. recurrence) at the time of resection. Among patients with initial unifocal disease, 57 % progressed to multifocal locoregional disease with subsequent recurrence, including 11 % with new tumors outside of the original resection field. No clinicopathologic or treatment-related variable, including the type or extent of resection, was predictive of either multifocal or 'outside field' progression. Multifocal disease is common in patients with WD/DD retroperitoneal liposarcoma, and tumors can also develop at remote, locoregional sites. Surgical resection remains the primary method of locoregional control in this disease; however, the aggressiveness of resection should be individualized, with consideration of both tumor and patient-related factors.
Haran, Mark J; Lord, Stephen R; Cameron, Ian D; Ivers, Rebecca Q; Simpson, Judy M; Lee, Bonsan B; Porwal, Mamta; Kwan, Marcella MS; Severino, Connie
2009-01-01
Background Recent research has shown that wearing multifocal glasses increases the risk of trips and falls in older people. The aim of this study is to determine whether the provision of single-lens distance glasses to older multifocal glasses wearers, with recommendations for wearing them for walking and outdoor activities, can prevent falls. We will also measure the effect of the intervention on health status, lifestyle activities and fear of falling, as well as the extent of adherence to the program. Methods/Design Approximately 580 older people who are regular wearers of multifocal glasses people will be recruited. Participants will be randomly allocated to either an intervention group (provision of single lens glasses, with counselling and advice about appropriate use) or a control group (usual care). The primary outcome measure will be falls (measured with 13 monthly calendars). Secondary measures will be quality of life, falls efficacy, physical activity levels and adverse events. Discussions The study will determine the impact of providing single-lens glasses, with advice about appropriate use, on preventing falls in older regular wearers of multifocal glasses. This pragmatic intervention, if found to be effective, will guide practitioners with regard to recommending appropriate glasses for minimising the risk of falls in older people. Trial Registration The protocol for this study was registered with the Clinical Trials.gov Protocol Registration System on June 7th 2006 (#350855). PMID:19321012
Interactive object modelling based on piecewise planar surface patches.
Prankl, Johann; Zillich, Michael; Vincze, Markus
2013-06-01
Detecting elements such as planes in 3D is essential to describe objects for applications such as robotics and augmented reality. While plane estimation is well studied, table-top scenes exhibit a large number of planes and methods often lock onto a dominant plane or do not estimate 3D object structure but only homographies of individual planes. In this paper we introduce MDL to the problem of incrementally detecting multiple planar patches in a scene using tracked interest points in image sequences. Planar patches are reconstructed and stored in a keyframe-based graph structure. In case different motions occur, separate object hypotheses are modelled from currently visible patches and patches seen in previous frames. We evaluate our approach on a standard data set published by the Visual Geometry Group at the University of Oxford [24] and on our own data set containing table-top scenes. Results indicate that our approach significantly improves over the state-of-the-art algorithms.
Photon momentum transfer plane for asteroid, meteoroid, and comet orbit shaping
NASA Technical Reports Server (NTRS)
Campbell, Jonathan W. (Inventor)
2004-01-01
A spacecraft docks with a spinning and/or rotating asteroid, meteoroid, comet, or other space object, utilizing a tether shaped in a loop and utilizing subvehicles appropriately to control loop instabilities. The loop is positioned about a portion of the asteroid and retracted thereby docking the spacecraft to the asteroid, meteoroid, comet, or other space object. A deployable rigidized, photon momentum transfer plane of sufficient thickness may then be inflated and filled with foam. This plane has a reflective surface that assists in generating a larger momentum from impinging photons. This plane may also be moved relative to the spacecraft to alter the forces acting on it, and thus on the asteroid, meteoroid, comet, or other space object to which it is attached. In general, these forces may be utilized, over time, to alter the orbits of asteroids, meteoroids, comets, or other space objects. Sensors and communication equipment may be utilized to allow remote operation of the rigidized, photon momentum transfer plane and tether.
Interactive object modelling based on piecewise planar surface patches☆
Prankl, Johann; Zillich, Michael; Vincze, Markus
2013-01-01
Detecting elements such as planes in 3D is essential to describe objects for applications such as robotics and augmented reality. While plane estimation is well studied, table-top scenes exhibit a large number of planes and methods often lock onto a dominant plane or do not estimate 3D object structure but only homographies of individual planes. In this paper we introduce MDL to the problem of incrementally detecting multiple planar patches in a scene using tracked interest points in image sequences. Planar patches are reconstructed and stored in a keyframe-based graph structure. In case different motions occur, separate object hypotheses are modelled from currently visible patches and patches seen in previous frames. We evaluate our approach on a standard data set published by the Visual Geometry Group at the University of Oxford [24] and on our own data set containing table-top scenes. Results indicate that our approach significantly improves over the state-of-the-art algorithms. PMID:24511219
System and method for detecting a faulty object in a system
Gunnels, John A.; Gustavson, Fred Gehrung; Engle, Robert Daniel
2010-12-14
A method (and system) for detecting at least one faulty object in a system including a plurality of objects in communication with each other in an n-dimensional architecture, includes probing a first plane of objects in the n-dimensional architecture and probing at least one other plane of objects in the n-dimensional architecture which would result in identifying a faulty object in the system.
System and method for detecting a faulty object in a system
Gunnels, John A [Brewster, NY; Gustavson, Fred Gehrung [Briarcliff Manor, NY; Engle, Robert Daniel [St. Louis, MO
2009-03-17
A method (and system) for detecting at least one faulty object in a system including a plurality of objects in communication with each other in an n-dimensional architecture, includes probing a first plane of objects in the n-dimensional architecture and probing at least one other plane of objects in the n-dimensional architecture which would result in identifying a faulty object in the system.
Kapoor, Akhil; Beniwal, Surender; Singhal, Mukesh Kumar; Kumar, Narender; Kumar, Vanita; Kumar, Harvindra Singh
2015-01-01
Perivascular epithelioid cell tumor (PEComa) is a group of sarcomas that exhibit a myomelanocytic phenotype and possess a unique cell type in the perivascular epithelioid cell. Traditionally HMB-45 immunoreactivity is the first criteria required to consider a tumor to be PEComa. We report a case of multifocal PEComa with negative HMB-45 marker. The patient presented with three big ulceroproliferative lesions; two over right thigh and one over the scalp in the right frontal region. The patient was prescribed with oral sirolimus to which good response was seen. To the best of our knowledge, this is the first case of HMB-45 negative multifocal malignant PEComa from India.
Multifocal hyperfunctioning thyroid carcinoma without metastases.
Nishida, Akiko T; Hirano, Shigeru; Asato, Ryo; Tanaka, Shinzo; Kitani, Yoshiharu; Honda, Nobumitsu; Fujiki, Nobuya; Miyata, Kouji; Fukushima, Hideyuki; Ito, Juichi
2008-09-01
Hyperthyroidism due to thyroid carcinoma is rare, and most cases are caused by hyperfunctioning metastatic thyroid carcinoma rather than primary carcinoma. Among primary hyperfunctioning thyroid carcinoma, multifocal thyroid carcinoma is exceedingly rare, with the only one case being reported in the literature. Here, we describe the case of a 62-year-old woman with multifocal functioning thyroid carcinoma. Technetium-99m (99m Tc) scintigraphic imaging showed four hot areas in the thyroid gland. Histopathological examination of all four nodules revealed papillary carcinoma, corresponding to hot areas in the 99m Tc scintigram. DNA sequencing of the thyrotropin receptor (TSH-R) gene from all nodules revealed no mutation, indicating that activation of TSH-R was unlikely in the pathophysiogenesis of hyperfunctioning thyroid carcinoma in the present case.
Application of the polychromatic defocus transfer function to multifocal lenses.
Schwiegerling, Jim; Choi, Junoh
2008-11-01
To model the performance of multifocal lenses in polychromatic lighting. The defocus transfer function (DTF) is a mathematical technique for illustrating the optical transfer function for all levels of defocus at a given wavelength. A polychromatic version of the DTF is developed that accounts for changes in cutoff frequency, reduction in diffraction efficiency, ocular chromatic aberration, and photoreceptor spectral sensitivity. The differences between the monochromatic and polychromatic DTF are illustrated with a diffractive multifocal intraocular lens. Polychromatic analysis shows an increase in depth of field of diffractive lenses relative to assessment at a single wavelength. The polychromatic DTF is a useful tool for analyzing presbyopia treatments under "white-light" viewing conditions and provides feedback to lens designers on anticipated performance.
Meng, Xin; Huang, Huachuan; Yan, Keding; Tian, Xiaolin; Yu, Wei; Cui, Haoyang; Kong, Yan; Xue, Liang; Liu, Cheng; Wang, Shouyu
2016-12-20
In order to realize high contrast imaging with portable devices for potential mobile healthcare, we demonstrate a hand-held smartphone based quantitative phase microscope using the transport of intensity equation method. With a cost-effective illumination source and compact microscope system, multi-focal images of samples can be captured by the smartphone's camera via manual focusing. Phase retrieval is performed using a self-developed Android application, which calculates sample phases from multi-plane intensities via solving the Poisson equation. We test the portable microscope using a random phase plate with known phases, and to further demonstrate its performance, a red blood cell smear, a Pap smear and monocot root and broad bean epidermis sections are also successfully imaged. Considering its advantages as an accurate, high-contrast, cost-effective and field-portable device, the smartphone based hand-held quantitative phase microscope is a promising tool which can be adopted in the future in remote healthcare and medical diagnosis.
Schröder, Lars; Fricker, Roland; Stein, Roland Gregor; Rink, Thomas; Fitz, Hartmut; Blasius, Sebastian; Wöckel, Achim; Müller, Thomas
2018-06-01
Sentinel lymph node biopsy (SLNB) alone has thus become an accepted surgical approach for patients with limited axillary metastatic disease. We investigated to what extent isolated tumor cells (ITC) or micrometastasis in SLNBs is associated with proven tumor cells or metastasis in non-sentinel lymph nodes. Furthermore, we investigated the feasibility of SLNB in multifocal and multicentric tumors as both entities have been considered a contraindication for this technique. 1214 women suffering from T1 and T2 invasive breast cancer, with clinically and sonographically insuspect axillary status and undergoing primary breast cancer surgery including SLNB and axillary staging in case of SLN (sentinel lymph node) metastases, were recruited into this multicentered study. ITC and micrometastases were found in 2.01 and 21.4% of patients with SLN metastases (n = 299). Among patients with sentinel micrometastases, 4.7% showed further axillary micrometastases, while only two patients (3.1%) had two axillary macrometastases. Multifocal and multicentric tumors were diagnosed in 9.3 and 2.6% of our patients who at least had one SLN resected, respectively. Detection rates of SLNs did not differ between the cohorts suffering from unicentric and multifocal or multicentric disease. Moreover, the portion of tumor-free SLNs, the number of SLNs with metastasis as well as the mean number of resected SLNs did not differ. No patient with sentinel node micrometastases showed more than two axillary macrometastases. Multifocal and multicentric disease is no contraindication for SLNB.
Primary scattered multifocal melanocytomas in spinal canal mimicking neurofibromatosis.
Yang, Chenlong; Fang, Jingyi; Li, Guang; Yang, Jun; Xu, Yulun
2016-08-01
Meningeal melanocytoma is an extremely rare pigmented tumor derived from leptomeningeal melanocytes. By and large, it is considered to be a well-differentiated and slow-growing benign lesion. Generally, meningeal melanocytomas are solitary lesions, and the occurrence of the primary multifocal form in the central nervous system is exceedingly rare; it has been previously reported in only six cases. The present report illustrates a 41-year-old woman with primary multifocal meningeal melanocytoma in the spinal canal. Contrary to earlier reports, the tumors presented with a scattered appearance mimicking neurofibromatosis. This study is a case report and review of literature. On admission, the cerebral magnetic resonance images of the patient were normal, whereas the spinal magnetic resonance images showed scattered multifocal nodules mimicking neurofibromatosis. Surgical resection of the responsible lesions was scheduled. In addition to this case presentation, relevant previous reports were reviewed, and the challenging diagnosis, management, and prognosis of meningeal melanocytoma are discussed. Gross total resection of the two largest lesions was achieved, and histopathological examinations confirmed the diagnosis. Despite the benign histopathological findings, the patient had an aggressive clinical course. On follow-up at 18 months after surgery, she succumbed to the disease. Clinicians should be alert to a potential aggressive clinical course of meningeal melanocytoma, despite its benign histopathological nature. Of particular note is multifocality and diffuse leptomeningeal hyperpigmentation, which may suggest a poor prognosis. A combined treatment including surgical resection and adjuvant radiotherapy should be considered, and long-term close follow-up is necessary. Copyright © 2016. Published by Elsevier Inc.
Wilson, M Edward; Trivedi, Rupal H; Burger, Berdine M
2009-12-01
There is a growing interest in multifocal intraocular lens (IOL) implantation in children because they lose accommodation when a cataract is removed. Many have assumed that very little, if any, eye growth occurs in the second decade of life. Multifocal IOL implantation requires precise biometry to arrive at the correct IOL power for spectacle independence. If the eye grows and the refraction becomes myopic, spectacle dependence may return. Therefore, knowing when the eye has completed its growth is critical to the decision of when to implant a multifocal IOL. Ninety-eight eyes were analyzed retrospectively. Each had at least two axial length (AL) measurements using immersion A-scan ultrasound in the second decade of life. Globe AL was 23.36 +/- 1.52 mm at initial measurement and 23.89 +/- 1.64 mm at last measurement. Measurement data show variable growth throughout the second decade of life. Based on our data, a theoretical patient was constructed with an AL at age 10 of 23.11 mm, who would need an IOL power of 21.5 for emmetropia. That same patient would have an AL of 23.76 mm (IOL power of 19.5) at age 15 and 24.41 mm (IOL power of 17.5) at age 20. That is a 4-diopter change in the IOL power need. Axial eye growth continues throughout the second decade of life, at least to age 20. These data have important implications for the use of multifocal IOLs in the preteen and teenage years.
Postmenopausal frontal fibrosing alopecia: a frontal variant of lichen planopilaris.
Kossard, S; Lee, M S; Wilkinson, B
1997-01-01
Lichen planopilaris usually produces multifocal areas of scarring alopecia. Recently, a condition in postmenopausal women characterized by progressive frontal hairline recession associated with scarring has been described. Our purpose was to study the clinical and histopathologic features and results of treatment in a group of women with the frontal variant of lichen planopilaris and to compare the immunohistochemical profile of scalp biopsy specimens from this subset with that found in the multifocal variant of lichen planopilaris. The clinical data as well as the histopathologic findings in 16 women with frontal fibrosing alopecia were collated. The immunohistochemical profile of six scalp biopsy specimens from the frontal hairline were compared with six specimens from women with multifocal lichen planopilaris. In addition to the progressive frontal fibrosing alopecia in all 16 women, total loss or a marked decrease of the eyebrows was observed in 13. No evidence of lichen planus was observed at other sites. In one patient multifocal areas of lichen planopilaris developed in the scalp. The frontal fibrosing alopecia was slowly progressive but has stabilized in five patients. Biopsy specimens from the frontal hairline showed histologic changes identical to lichen planopilaris. Immunophenotyping failed to reveal any significant differences between the frontal and multifocal variants. No effective treatments emerged although oral steroids and antimalarials may temporarily slow the course. Hormone replacement therapy did not appear to influence the course of the alopecia. Progressive frontal fibrosing alopecia is a clinically distinct variant of lichen planopilaris that affects in particular elderly women and frequently involves the eyebrows. The basis for this lichenoid tissue reaction targeting frontal scalp follicles and eyebrows is unknown.
Randomized Crossover Trial of Silicone Hydrogel Presbyopic Contact Lenses.
Sivardeen, Ahmed; Laughton, Deborah; Wolffsohn, James S
2016-02-01
To assess the performance of four commercially available silicone hydrogel multifocal monthly contact lens designs against monovision. A double-masked randomized crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal, and monovision with Biofinity contact lenses was conducted on 35 presbyopes (54.3 ± 6.2 years). After 4 weeks of wear, visual performance was quantified by high- and low-contrast visual acuity under photopic and mesopic conditions, reading speed, defocus curves, stereopsis, halometry, aberrometry, Near Activity Visual Questionnaire rating, and subjective quality of vision scoring. Bulbar, limbal, and palpebral hyperemia and corneal staining were graded to monitor the impact of each contact lens on ocular physiology. High-contrast photopic visual acuity (p = 0.102), reading speed (F = 1.082, p = 0.368), and aberrometry (F = 0.855, p = 0.493) were not significantly different between presbyopic lens options. Defocus curve profiles (p < 0.001), stereopsis (p < 0.001), halometry (F = 4.101, p = 0.004), Near Activity Visual Questionnaire (F = 3.730, p = 0.007), quality of vision (p = 0.002), bulbar hyperemia (p = 0.020), and palpebral hyperemia (p = 0.012) differed significantly between lens types, with the Biofinity multifocal lens design principal (center-distance lens was fitted to the dominant eye and a center-near lens to the nondominant eye) typically outperforming the other lenses. Although ocular aberration variation between individuals largely masks the differences in optics between current multifocal contact lens designs, certain design strategies can outperform monovision, even in early presbyopes.
Changes in accommodation and ocular aberration with simultaneous vision multifocal contact lenses.
Ruiz-Alcocer, Javier; Madrid-Costa, David; Radhakrishnan, Hema; Ferrer-Blasco, Teresa; Montés-Micó, Robert
2012-09-01
The aim of this study was to evaluate ocular aberration changes through different simultaneous vision multifocal contact lenses (CLs). Eighteen young-adult subjects with a mean age of 29.8±2.11 years took part. Changes in accommodative response, spherical aberration (C(4)(0)), horizontal coma (C(3)(1)), vertical coma (C(3)(-1)), and root mean square (RMS) of higher-order aberrations (HOAs, third to sixth orders) were evaluated. Measurements were obtained with a distance-single vision CL and 2 aspheric multifocal CLs of simultaneous focus center-near design (PureVision Low Add and PureVision High Add) for 2 accommodative stimuli (-2.50 and -4.00 D). All measurements were performed monocularly with a Hartmann-Shack aberrometer (IRX-3; Imagine Eyes, Orsay, France). No statistically significant differences were found in accommodative responses to -2.50- and -4.00-D stimuli between the single vision CL and the 2 multifocal CLs. Spherical aberration was found to decrease and become more negative with accommodation for both stimuli with all three CLs. Horizontal coma decreased significantly with accommodation (-2.5- and -4.00-D stimuli) for the distance-single vision CLs (P=0.002 and P=0.003). No differences were found in vertical coma Zernike coefficients. The RMS of HOAs was found to decrease only with the single vision CLs for both stimuli (P<0.01). Data obtained in this study suggest that in young subjects, the multifocal CLs studied do not induce large changes in accommodative response compared with the distance-single vision CLs. Spherical aberration reduced significantly with accommodation.
Multifocal Epithelial Hyperplasia.
Agnew, Caitlin; Alexander, Sherene; Prabhu, Neeta
2017-01-15
Multifocal epithelial hyperplasia is a rare disease associated with human papilloma virus types 13 and 32. Diagnosis is based on clinical and histopathological findings, and most lesions are asymptomatic and regress spontaneously with time. The purpose of this paper is to describe a five-year-old girl who presented with multiple intraoral lesions on the buccal mucosa and tongue, which regressed spontaneously in 15 months.
Association of abnormal plasma bilirubin with aggressive HCC phenotype
Carr, Brian I.; Guerra, Vito; Giannini, Edoardo G.; Farinati, Fabio; Ciccarese, Francesca; Rapaccini, Gian Ludovico; Marco, Maria Di; Benvegnù, Luisa; Zoli, Marco; Borzio, Franco; Caturelli, Eugenio; Chiaramonte, Maria; Trevisani, Franco
2014-01-01
Background Cirrhosis-related abnormal liver function is associated with predisposition to HCC, features in several HCC classification systems and is an HCC prognostic factor. Aims To examine the phenotypic tumor differences in HCC patients with normal or abnormal plasma bilirubin levels. Methods A 2,416 patient HCC cohort was studied and dichotomized into normal and abnormal plasma bilirubin groups. Their HCC characteristics were compared for tumor aggressiveness features, namely blood AFP levels, tumor size, presence of PVT and tumor multifocality. Results In the total cohort, elevated bilirubin levels were associated with higher AFP levels, increased PVT and multifocality and lower survival, despite similar tumor sizes. When different tumor size terciles were compared, similar results were found, even for small tumor size patients. A multiple logistic regression model for PVT or tumor multifocality showed increased OddsRatios for elevated levels of GGTP, bilirubin and AFP and for larger tumor sizes. Conclusions HCC patients with abnormal bilirubin levels had worse prognosis than patients with normal bilirubin. They also had increased incidence of PVT and tumor multifocality and higher AFP levels, in patients with both small and larger tumors. The results show an association between bilirubin levels and indices of HCC aggressiveness. PMID:24787296
Outcomes in multifocal neuroblastoma as part of the neurocristopathy syndrome.
Williams, Phoebe; Wegner, Eva; Ziegler, David S
2014-08-01
The neurocristopathy syndrome occurs because of a germline mutation of the paired-like homeobox 2b (PHOX2B) gene at 4p12, a neurogenesis regulator gene. The result is abnormal neural crest cell development resulting in congenital central hypoventilation syndrome, Hirschsprung disease, and neuroblastoma (NB), which is often multifocal and disseminated in its presentation. Previously, such widespread disease was regarded as highly aggressive and treated either with palliative intent or, conversely, with very intense, high-dose chemotherapy. We now present a patient who had neurocristopathy syndrome who had multifocal NB associated with an underlying germline PHOX2B mutation. He was treated conservatively with surgery and low-dose chemotherapy. After treatment he had extensive residual disease that has continued to mature despite no further treatment. A literature review identified 26 similar patients presenting with multifocal NB as part of the neurocristopathy syndrome. In all cases the NB behaved in an indolent manner with no deaths from tumor reported when patients received appropriate treatment. These provocative findings suggest for the first time that children who have neurocristopathy-associated NB should be treated conservatively, despite the aggressive appearance of their disease. Copyright © 2014 by the American Academy of Pediatrics.
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
AIM To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). METHODS Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected. PMID:29181318
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.
Cywinski, Adam; Piwonska-Lobermajer, Anna; Penter, Sandra
2016-08-01
A retrospective analysis of visual function and postoperative complaints in patients after posterior vitrectomy and multifocal Mplus or MplusX intraocular lens implantation. 14 patients (14 eyes) were enrolled in the study. All patients underwent posterior vitrectomy due to underlying retinal pathologies. A combined procedure of phacovitrectomy was performed in some patients, whereas others underwent a separate cataract extraction as a second stage of treatment. The Mplus or MplusX intraocular lenses were implanted in all cases and the postoperative visual function and patient complaints were analysed. Multifocal lens explantation was not necessary in any case. Good uncorrected distance and near visual acuity was achieved in most cases. When implanted prior to vitrectomy, the intraocular lenses did not limit the view into the posterior segment, so precise manipulations within the macula and peripheral retina were feasible. The right choice between Mplus and MplusX minimises the rate of postoperative complaints. Conslusions: The multifocal Mplus and MplusX intraocular lenses offer a good alternative for patients who need posterior vitrectomy and still want to achieve good uncorrected distance and near visual acuity.
NASA Technical Reports Server (NTRS)
Alvertos, Nicolas; Dcunha, Ivan
1992-01-01
A feature set of two dimensional curves is obtained after intersecting symmetric objects like spheres, cones, cylinders, ellipsoids, paraboloids, and parallelepipeds with two planes. After determining the location and orientation of the objects in space, these objects are aligned so as to lie on a plane parallel to a suitable coordinate system. These objects are then intersected with a horizontal and a vertical plane. Experiments were carried out with range images of sphere and cylinder. The 3-D discriminant approach was used to recognize quadric surfaces made up of simulated data. Its application to real data was also studied.
The Octree Encoding Method for Efficient Solid Modeling.
1982-08-01
vertex point of a test obel is interior or exterior to the object. If the object is a convex polyhedron , the surface is described by a L 55 yp Test Obel...values can be generated by adding an offset from a pre-computed table. For a convex polyhedron , if a point is in the positive . .half-space of all face...planes, then it is interior to the polyhedron . If it is in the negative half-plane of any face plane, then it is exterior to the object. Otherwise, the
Multifocal choroiditis - an unusual finding in Crohns disease.
Vianna, R N G; Ozdal, P C; Deschnes, J
To report a patient with Crohns disease and acute decreased vision in one eye secondary to multifocal choroiditis and serous retinal detachment. A complete ocular examination, including fluorescein angiography, was performed. Fundus biomicroscopy disclosed multifocal, deep, discretely elevated yellowish lesions at the posterior pole of the affected eye. Fluorescein angiographic study of these lesions revealed early hypofluorescence followed by late yperfluorescence. Subtenonian injection of corticosteroids rapidly induced remission of the choroidal lesions. Chorioretinal involvement in patients with Crohns disease may or may not be related to reactivation of this disorder. Therefore, even patients without gastrointestinal symptoms who present with posterior segment inflammation must be informed of this. The chorioretinal inflammatory lesions do seem to respond promptly to periocular injection of corticosteroids. (Eur J Ophthalmol 2004; 14: 345-9).
Multifocal Neuropathy: Expanding the Scope of Double Crush Syndrome.
Cohen, Brian H; Gaspar, Michael P; Daniels, Alan H; Akelman, Edward; Kane, Patrick M
2016-12-01
Double crush syndrome (DCS), as it is classically defined, is a clinical condition composed of neurological dysfunction due to compressive pathology at multiple sites along a single peripheral nerve. The traditional definition of DCS is narrow in scope because many systemic pathologic processes, such as diabetes mellitus, drug-induced neuropathy, vascular disease and autoimmune neuronal damage, can have deleterious effects on nerve function. Multifocal neuropathy is a more appropriate term describing the multiple etiologies (including compressive lesions) that may synergistically contribute to nerve dysfunction and clinical symptoms. This paper examines the history of DCS and multifocal neuropathy, including the epidemiology and pathophysiology in addition to principles of evaluation and management. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Hrabovský, Miroslav
2014-01-01
The purpose of the study is to show a proposal of an extension of a one-dimensional speckle correlation method, which is primarily intended for determination of one-dimensional object's translation, for detection of general in-plane object's translation. In that view, a numerical simulation of a displacement of the speckle field as a consequence of general in-plane object's translation is presented. The translation components a x and a y representing the projections of a vector a of the object's displacement onto both x- and y-axes in the object plane (x, y) are evaluated separately by means of the extended one-dimensional speckle correlation method. Moreover, one can perform a distinct optimization of the method by reduction of intensity values representing detected speckle patterns. The theoretical relations between the translation components a x and a y of the object and the displacement of the speckle pattern for selected geometrical arrangement are mentioned and used for the testifying of the proposed method's rightness. PMID:24592180
Spatial phase-shift dual-beam speckle interferometry.
Gao, Xinya; Yang, Lianxiang; Wang, Yonghong; Zhang, Boyang; Dan, Xizuo; Li, Junrui; Wu, Sijin
2018-01-20
The spatial phase-shift technique has been successfully applied to an out-of-plane speckle interferometry system. Its application to a pure in-plane sensitive system has not been reported yet. This paper presents a novel optical configuration that enables the application of the spatial phase-shift technique to pure in-plane sensitive dual-beam speckle interferometry. The new spatial phase-shift dual-beam speckle interferometry (SPS-DBSP) uses a dual-beam in-plane electronic speckle pattern interferometry configuration with individual aperture shears, avoiding the interference in the object plane by the use of a low-coherence source, and different optical paths. The measured object is illuminated by two incoherent beams that are generated by a delay line, which is larger than the coherence length of the laser. The two beams reflected from the object surface interfere with each other at the CCD plane because of different optical paths. A spatial phase shift is introduced by the angle between the two apertures when they are mapped to the same optical axis. The phase of the in-plane deformation can directly be extracted from the speckle patterns by the Fourier transform method. The capability of SPS-DBSI is demonstrated by theoretical discussion as well as experiments.
[Multifocal Langerhans cell histiocytosis of bone: late revelation in a 76-year-old woman].
Lahiani, D; Hammami, B K; Maâloul, I; Frikha, M; Baklouti, S; Jlidi, R; Ben Jemaâ, M
2008-03-01
Langerhans cell histiocytosis or histiocytosis X has a variable course from a self-limited eosinophilic granuloma to an aggressive disseminated disease. It mainly affects children. We report a 76-year-old woman with multifocal bone histiocytosis X, involving the rachis, an iliac bone and the skull. The diagnosis has been established by histological exam. Outcome was favourable after chemotherapy.
Vu, Lien T; Chen, Chao-Chang A; Lee, Chia-Cheng; Yu, Chia-Wei
2018-04-20
This study aims to develop a compensating method to minimize the shrinkage error of the shell mold (SM) in the injection molding (IM) process to obtain uniform optical power in the central optical zone of soft axial symmetric multifocal contact lenses (CL). The Z-shrinkage error along the Z axis or axial axis of the anterior SM corresponding to the anterior surface of a dry contact lens in the IM process can be minimized by optimizing IM process parameters and then by compensating for additional (Add) powers in the central zone of the original lens design. First, the shrinkage error is minimized by optimizing three levels of four IM parameters, including mold temperature, injection velocity, packing pressure, and cooling time in 18 IM simulations based on an orthogonal array L 18 (2 1 ×3 4 ). Then, based on the Z-shrinkage error from IM simulation, three new contact lens designs are obtained by increasing the Add power in the central zone of the original multifocal CL design to compensate for the optical power errors. Results obtained from IM process simulations and the optical simulations show that the new CL design with 0.1 D increasing in Add power has the closest shrinkage profile to the original anterior SM profile with percentage of reduction in absolute Z-shrinkage error of 55% and more uniform power in the central zone than in the other two cases. Moreover, actual experiments of IM of SM for casting soft multifocal CLs have been performed. The final product of wet CLs has been completed for the original design and the new design. Results of the optical performance have verified the improvement of the compensated design of CLs. The feasibility of this compensating method has been proven based on the measurement results of the produced soft multifocal CLs of the new design. Results of this study can be further applied to predict or compensate for the total optical power errors of the soft multifocal CLs.
Multi-focal HIFU reduces cavitation in mild-hyperthermia.
Chaplin, Vandiver; Caskey, Charles F
2017-01-01
Mild-hyperthermia therapy (40-45 °C) with high-intensity focused ultrasound (HIFU) is a technique being considered in a number of different treatments such as thermally activated drug delivery, immune-stimulation, and as a chemotherapy adjuvant. Mechanical damage and loss of cell viability associated with HIFU-induced acoustic cavitation may pose a risk during these treatments or may hinder their success. Here we present a method that achieves mild heating and reduces cavitation by using a multi-focused HIFU beam. We quantify cavitation level and temperature rise in multi-focal sonications and compare it to single-focus sonications at the transducer geometric focus. Continuous wave sonications were performed with the Sonalleve V2 transducer in gel phantoms and pork at 5, 10, 20, 40, 60, 80 acoustic watts for 30 s. Cavitation activity was measured with two ultrasound (US) imaging probes, both by computing the raw channel variance and using passive acoustic mapping (PAM). Temperature rise was measured with MR thermometry at 3 T. Cavitation and heating were compared for single- and multi-focal sonication geometries. Multi-focal sonications used four points equally spaced on a ring of either 4 mm or 8 mm diameter. Single-focus sonications were not steered. Multi-focal sonication generated distinct foci that were visible in MRI thermal maps in both phantoms and pork, and visible in PAM images in phantoms only. Cavitation activity (measured by channel variance) and mean PAM image value were highly correlated (r > 0.9). In phantoms, cavitation exponentially decreased over the 30-second sonication, consistent with depletion of cavitation nuclei. In pork, sporadic spikes signaling cavitation were observed with single focusing only. In both materials, the widest beam reduced average and peak cavitation level by a factor of two or more at each power tested when compared to a single focus. The widest beam reduced peak temperature by at least 10 °C at powers above 5 W, and created heating that was more spatially diffuse than single focus, resulting in more voxels in the mild heating (3-8 °C) range. Multi-focal HIFU can be used to achieve mild temperature elevation and reduce cavitation activity.
Rajshekhar, Gannavarpu; Gorthi, Sai Siva; Rastogi, Pramod
2011-12-01
The paper introduces a method for simultaneously measuring the in-plane and out-of-plane displacement derivatives of a deformed object in digital holographic interferometry. In the proposed method, lasers of different wavelengths are used to simultaneously illuminate the object along various directions such that a unique wavelength is used for a given direction. The holograms formed by multiple reference-object beam pairs of different wavelengths are recorded by a 3-color CCD camera with red, green, and blue channels. Each channel stores the hologram related to the corresponding wavelength and hence for the specific direction. The complex reconstructed interference field is obtained for each wavelength by numerical reconstruction and digital processing of the recorded holograms before and after deformation. Subsequently, the phase derivative is estimated for a given wavelength using two-dimensional pseudo Wigner-Ville distribution and the in-plane and out-of-plane components are obtained from the estimated phase derivatives using the sensitivity vectors of the optical configuration. © 2011 Optical Society of America
Lopez-Villanueva, Maria Eugenia; Conde-Ferráez, Laura; Ayora-Talavera, Guadalupe; Cerón-Espinosa, Jose D; González-Losa, Maria del Refugio
2011-01-01
Multifocal epithelial hyperplasia (MEH) is a disease of the oral mucosa. Human papillomaviruses 13 and 32 have been detected in these lesions. We describe the epidemiology and clinical characteristics of patients with MEH in a rural community in the Mayan area of Mexico with 53 cases and 54 controls. Clinical and epidemiological data were collected through a direct interview. Oral cell samples were collected with a cytobrush. Subjects collected their own saliva sample in a sterile bottle. All samples were tested for HPV 13 and 32 by polymerase chain reaction using specific primers. Of the 53 patients and 54 healthy subjects, 56% were < 12 years old, 25% were males and 75% females. Evolution of the lesions was between two months and 17 years. The lesions affected lips, jugal mucosa, and tongue, 96% had multiple lesions. From 53 patients, fifty samples of oral cells and 31 samples of saliva were analyzed. HPV 13 was detected in 100% oral cell and 100% saliva samples studied. 16 healthy subjects were HVP 13 positive. A highly significant association of HPV 13 infection and MEH was found, as determined by chi square test (p = 0.00) Household transmission of HPV 13 may happen through saliva and the shared use of contaminated objects.
Fundus Autofluorescence Imaging of the White Dot Syndromes
Yeh, Steven; Forooghian, Farzin; Wong, Wai T.; Faia, Lisa J.; Cukras, Catherine; Lew, Julie C.; Wroblewski, Keith; Weichel, Eric D.; Meyerle, Catherine B.; Sen, Hatice Nida; Chew, Emily Y.; Nussenblatt, Robert B.
2011-01-01
Objective To characterize the fundus autofluorescence (FAF) findings in patients with white dot syndromes (WDSs). Methods Patients with WDSs underwent ophthalmic examination, fundus photography, fluorescein angiography, and FAF imaging. Patients were categorized as having no, minimal, or predominant foveal hypoautofluorescence. The severity of visual impairment was then correlated with the degree of foveal hypoautofluorescence. Results Fifty-five eyes of 28 patients with WDSs were evaluated. Visual acuities ranged from 20/12.5 to hand motions. Diagnoses included serpiginous choroidopathy (5 patients), birdshot retinochoroidopathy (10), multifocal choroiditis (8), relentless placoid chorioretinitis (1), presumed tuberculosis-associated serpiginouslike choroidopathy (1), acute posterior multifocal placoid pigment epitheliopathy (1), and acute zonal occult outer retinopathy (2). In active serpiginous choroidopathy, notable hyperautofluorescence in active disease distinguished it from the variegated FAF features of tuberculosis-associated serpiginouslike choroidopathy. The percentage of patients with visual acuity impairment of less than 20/40 differed among eyes with no, minimal, and predominant foveal hypoautofluorescence (P<.001). Patients with predominant foveal hypoautofluorescence demonstrated worse visual acuity than those with minimal or no foveal hypoautofluorescence (both P<.001). Conclusions Fundus autofluorescence imaging is useful in the evaluation of the WDS. Visual acuity impairment is correlated with foveal hypoautofluorescence. Further studies are needed to evaluate the precise role of FAF imaging in the WDSs. PMID:20065216
Abou-El-Ardat, Khalil; Seifert, Michael; Becker, Kerstin; Eisenreich, Sophie; Lehmann, Matthias; Hackmann, Karl; Rump, Andreas; Meijer, Gerrit; Carvalho, Beatriz; Temme, Achim; Schackert, Gabriele; Schröck, Evelin; Krex, Dietmar; Klink, Barbara
2017-04-01
The evolution of primary glioblastoma (GBM) is poorly understood. Multifocal GBM (ie, multiple synchronous lesions in one patient) could elucidate GBM development. We present the first comprehensive study of 12 GBM foci from 6 patients using array-CGH, spectral karyotyping, gene expression arrays, and next-generation sequencing. Multifocal GBMs genetically resemble primary GBMs. Comparing foci from the same patient proved their monoclonal origin. All tumors harbored alterations in the 3 GBM core pathways: RTK/PI3K, p53, and RB regulatory pathways with aberrations of EGFR and CDKN2A/B in all (100%) patients. This unexpected high frequency reflects a distinct genetic signature of multifocal GBMs and might account for their highly malignant and invasive phenotype. Surprisingly, the types of mutations in these genes/pathways were different in tumor foci from the same patients. For example, we found distinct mutations/aberrations in PTEN, TP53, EGFR, and CDKN2A/B, which therefore must have occurred independently and late during tumor development. We also identified chromothripsis as a late event and in tumors with wild-type TP53. Only 2 events were found to be early in all patients: single copy loss of PTEN and TERT promoter point mutations. Multifocal GBMs develop through parallel genetic evolution. The high frequency of alterations in 3 main pathways suggests that these are essential steps in GBM evolution; however, their late occurrence indicates that they are not founder events but rather subclonal drivers. This might account for the marked genetic heterogeneity seen in primary GBM and therefore has important implications for GBM therapy. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society for Neuro-Oncology.
Barohn, Richard J.; Katz, Jonathan
2014-01-01
Chronic acquired demyelinating neuropathies (CADP) are an important group of immune neuromuscular disorders affecting myelin. These are distinct from chronic inflammatory demyelinating polyneuropathy (CIDP). Classically, CIDP is characterized by proximal and distal weakness, large fiber sensory loss, elevated cerebrospinal fluid (CSF) protein content, demyelinating changes nerve conduction studies or nerve biopsy, and response to immunomodulating treatment. In this chapter we discuss CADP with emphasis on multifocal motor neuropathy (MMN), multifocal acquired demyelinating sensory and motor neuropathy (MADSAM), distal acquired demyelinating symmetric (DADS) neuropathy and conclude with less common variants. While each of these entities has distinctive laboratory and electrodiagnostic features that aid in their diagnosis, clinical characteristics are of paramount importance in diagnosing specific conditions and determining the most appropriate therapies. Unlike CIDP, MMN is typically asymmetric and affects only the motor nerve fibers. MMN is a rare disease that presents chronically, over several years of progression affecting the arms are more commonly than the legs. Men are more likely than women to develop MMN. MADSAM should be suspected in patients who have weakness and loss of sensation in primarily one arm or leg which progresses slowly over several months to years. It is important in patient with multifocal demyelinating clinical presentation to distinguish MMN from MADSAM since corticosteroids are not effective in MMN where the mainstay of therapy is intravenous gammaglobulin (IVIg). DADS can be subdivided into DADS-M (associated woth M-protein) and DADS-I which is idioapthic. While DADS-I patients respond somewhat to immunotherapy, DADS-M patients present with distal predominant sensorimotor demyelinating neuropathy phenotype and are notoriously refractory to immunotherapies regardless of antibodies to myelin-associated glycoprotein (MAG). Our knowledge regarding pathogenesis, diagnosis and management continues to expand, resulting in improved opportunities for identification and treatment. PMID:23642723
Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki
2017-01-01
AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776
Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki
2017-01-01
To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.
The effect of multifocal soft contact lenses on peripheral refraction.
Kang, Pauline; Fan, Yvonne; Oh, Kelly; Trac, Kevin; Zhang, Frank; Swarbrick, Helen A
2013-07-01
To compare changes in peripheral refraction with single-vision (SV) and multifocal (MF) correction of distance central refraction with commercially available SV and MF soft contact lenses (SCLs) in young myopic adults. Thirty-four myopic adult subjects were fitted with Proclear Sphere and Proclear Multifocal SCLs to correct their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with the two different types of SCL correction. At baseline, refraction was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared with center at 30 and 35 degrees in the temporal visual field (VF) in low myopes, and at 30 and 35 degrees in the temporal VF, and 10, 30, and 35 degrees in the nasal VF in moderate myopes. Single-vision and MF distance correction with Proclear Sphere and Proclear Multifocal SCLs, respectively, caused a hyperopic shift in refraction at all locations in the horizontal VF. Compared with SV correction, MF SCL correction caused a significant relative myopic shift at all locations in the nasal VF in both low and moderate myopes and also at 35 degrees in the temporal VF in moderate myopes. Correction of central refractive error with SV and MF SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. Single-vision SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction to experience an absolute hyperopic defocus. Multifocal SCL correction resulted in a relative myopic shift in peripheral refraction compared with SV SCL correction. This myopic shift may explain recent reports of reduced myopia progression rates with MF SCL correction.
[Multifocal phakic intraocular lens implant to correct presbyopia].
Baikoff, G; Matach, G; Fontaine, A; Ferraz, C; Spera, C
2005-03-01
Presbyopic surgery is considered as the new frontier in refractive surgery. Different solutions are proposed: myopization of one eye, insertion of an accommodative crystalline lens, scleral surgery, the effects of which are still unknown, and finally multifocal phakic implants. We therefore decided to undertake a prospective study under the Huriet law to determine its efficacy and specify the conditions required for an anterior chamber multifocal phakic implant. Fifty-five eyes of 33 patients received an anterior chamber foldable multifocal phakic implant. Twenty-one females and 12 males underwent surgery. Initial refraction was between -5D and +5D. The implant's single addition was +2.50. Recuperating a distant uncorrected visual acuity of 0.6 or better and near uncorrected vision of Parinaud 3 or better can be considered a very good postoperative result. Average follow-up was 42.6+/-18 weeks. Mean postoperative refraction was -0.12+/-0.51 D. Mean postoperative uncorrected visual acuity was 0.78+/-0.20. Postoperative uncorrected visual acuity was Parinaud 2.3+/-0.6. Eighty-four percent of eyes operated on recuperated 0.6 or better without correction and Parinaud 3 or better without correction. Lenses in four eyes were explanted for different reasons, essentially optical, and no severe anatomical complications were observed. Placing an anterior chamber multifocal phakic implant to correct presbyopia is an effective technique with good predictability and has the advantage of being reversible in case of intolerance, optical parasite effects or undesired complications. Considering the particularity of this surgery, it is imperative to respect very strict inclusion criteria: anterior chamber depth equal to or above 3.1 mm, open angle, endothelial cell count equal to or above 2000 cells/mm2, absence of an incipient cataract or the slightest evidence of macular alteration.
Monaco, Gaspare; Gari, Mariangela; Di Censo, Fabio; Poscia, Andrea; Ruggi, Giada; Scialdone, Antonio
2017-06-01
To compare the visual outcomes and quality of vision of 2 new diffractive multifocal intraocular lenses (IOLs) with those of a monofocal IOL. Fatebenefratelli e Oftalmico Hospital, Milan, Italy. Prospective case series. Patients had bilateral cataract surgery with implantation of a trifocal IOL (Panoptix), an extended-range-of-vision IOL (Symfony), or a monofocal IOL (SN60WF). Postoperative examinations included assessing distance, intermediate, and near visual acuity; binocular defocus; intraocular and total aberrations; point-spread function (PSF); modulation transfer function (MTF); retinal straylight; and quality-of-vision (QoV) and spectacle-dependence questionnaires. Seventy-six patients (152 eyes) were assessed for study eligibility. Twenty patients (40 eyes) in each arm of the study (60 patients, 120 eyes) completed the outcome assessment. At the 4-month follow-up, the trifocal group had significantly better near visual acuity than the extended-range-of-vision group (P = .005). The defocus curve showed the trifocal IOL had better intermediate/near performance than the extended-range-of-vision IOL and both multifocal IOLs performed better than the monofocal IOL. Intragroup comparison of the total higher-order aberrations, PSF, MTF, and retinal straylight were not statistically different. The QoV questionnaire results showed no differences in dysphotopsia between the multifocal IOL groups; however, the results were significantly higher than in the monofocal IOL group. Both multifocal IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the trifocal IOL might be better for patients with near-vision requirements. The significant perception of visual side effects indicates that patients still must be counseled about these effects before a multifocal IOL is implanted. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Inoue, Makoto; Noda, Toru; Mihashi, Toshifumi; Ohnuma, Kazuhiko; Bissen-Miyajima, Hiroko; Hirakata, Akito
2011-04-01
To evaluate the quality of the image of a grating target placed in a model eye viewed through multifocal intraocular lenses (IOLs). Laboratory investigation. Refractive (NXG1 or PY60MV) or diffractive (ZM900 or SA60D3) multifocal IOLs were placed in a fluid-filled model eye with human corneal aberrations. A United States Air Force resolution target was placed on the posterior surface of the model eye. A flat contact lens or a wide-field contact lens was placed on the cornea. The contrasts of the gratings were evaluated under endoillumination and compared to those obtained through a monofocal IOL. The grating images were clear when viewed through the flat contact lens and through the central far-vision zone of the NXG1 and PY60MV, although those through the near-vision zone were blurred and doubled. The images observed through the central area of the ZM900 with flat contact lens were slightly defocused but the images in the periphery were very blurred. The contrast decreased significantly in low frequencies (P<.001). The images observed through the central diffractive zone of the SA60D3 were slightly blurred, although the images in the periphery were clearer than that of the ZM900. The images were less blurred in all of the refractive and diffractive IOLs with the wide-field contact lens. Refractive and diffractive multifocal IOLs blur the grating target but less with the wide-angle viewing system. The peripheral multifocal optical zone may be more influential on the quality of the images with contact lens system. Copyright © 2011 Elsevier Inc. All rights reserved.
High contrast imaging through adaptive transmittance control in the focal plane
NASA Astrophysics Data System (ADS)
Dhadwal, Harbans S.; Rastegar, Jahangir; Feng, Dake
2016-05-01
High contrast imaging, in the presence of a bright background, is a challenging problem encountered in diverse applications ranging from the daily chore of driving into a sun-drenched scene to in vivo use of biomedical imaging in various types of keyhole surgeries. Imaging in the presence of bright sources saturates the vision system, resulting in loss of scene fidelity, corresponding to low image contrast and reduced resolution. The problem is exacerbated in retro-reflective imaging systems where the light sources illuminating the object are unavoidably strong, typically masking the object features. This manuscript presents a novel theoretical framework, based on nonlinear analysis and adaptive focal plane transmittance, to selectively remove object domain sources of background light from the image plane, resulting in local and global increases in image contrast. The background signal can either be of a global specular nature, giving rise to parallel illumination from the entire object surface or can be represented by a mosaic of randomly orientated, small specular surfaces. The latter is more representative of real world practical imaging systems. Thus, the background signal comprises of groups of oblique rays corresponding to distributions of the mosaic surfaces. Through the imaging system, light from group of like surfaces, converges to a localized spot in the focal plane of the lens and then diverges to cast a localized bright spot in the image plane. Thus, transmittance of a spatial light modulator, positioned in the focal plane, can be adaptively controlled to block a particular source of background light. Consequently, the image plane intensity is entirely due to the object features. Experimental image data is presented to verify the efficacy of the methodology.
Ladi, Jeevan S; Shah, Nitant A
2016-01-01
We report the first case of toric multifocal intraocular lens (IOL) implantation in both the eyes of a young patient of Alport syndrome with anterior and posterior lenticonus with a successful outcome. An 18-year-old female patient presented with progressively blurred vision in both eyes since 4–5 years not improving with glasses. Refraction showed high myopia with astigmatism; however, the vision did not improve beyond 6/60 with glasses correction. Clinical examination on slit lamp showed anterior and posterior lenticonus bilaterally with a classical oil droplet appearance. We performed clear lens extraction by phacoemulsification with toric multifocal IOL implantation in both eyes. Postoperatively, the patient achieved an excellent refractive outcome with the unaided vision of 6/9, N6 in both eyes. PMID:27958211
Intraocular Lenses for the Treatment of Age-Related Cataracts
2009-01-01
Executive Summary Objective The objective of the report is to examine the comparative effectiveness and cost-effectiveness of various intraocular lenses (IOLs) for the treatment of age-related cataracts. Clinical Need: Target Population and Condition A cataract is a hardening and clouding of the normally transparent crystalline lens that may result in a progressive loss of vision depending on its size, location and density. The condition is typically bilateral, seriously compromises visual acuity and contrast sensitivity and increases glare. Cataracts can also affect people at any age, however, they usually occur as a part of the natural aging process. The occurrence of cataracts increases with age from about 12% at age 50 years, to 60% at age 70. In general, approximately 50% of people 65 year of age or older have cataracts. Mild cataracts can be treated with a change in prescription glasses, while more serious symptoms are treated by surgical removal of the cataract and implantation of an IOL. In Ontario, the estimated prevalence of cataracts increased from 697,000 in 1992 to 947,000 in 2004 (35.9% increase, 2.4% annual increase). The number of cataract surgeries per 1,000 individuals at risk of cataract increased from 64.6 in 1992 to 140.4 in 1997 (61.9% increase, 10.1% annual increase) and continued to steadily increase to 115.7 in 2004 (10.7% increase, 5.2% increase per year). Description of Technology/Therapy IOLs are classified either as monofocal, multifocal, or accommodative. Traditionally, monofocal (i.e.. fixed focusing power) IOLs are available as replacement lenses but their implantation can cause a loss of the eye’s accommodative capability (which allows variable focusing). Patients thus usually require eyeglasses after surgery for reading and near vision tasks. Multifocal IOLs aim to improve near and distant vision and obviate the need for glasses. Potential disadvantages include reduced contrast sensitivity, halos around lights and glare. Accommodating IOLs are designed to move with ciliary body contraction during accommodation and, therefore, offer a continuous range of vision (i.e. near, intermediate and distant vision) without the need for glasses. Purported advantages over multifocal IOLs include the avoidance of haloes and no reduction in contrast sensitivity. Polymethyl methacrylate (PMMA) was the first material used in the fabrication of IOLs and has inherent ultraviolet blocking abilities. PMMA IOLs are inflexible, however, and require a larger incision for implantation compared with newer foldable silicone (hydrophobic) and acrylic (hydrophobic or hydrophilic) lenses. IOLs can be further sub-classified as being either aspheric or spheric, blue/violet filtered or non-filtered or 1- or 3-piece. Methods of Evidence-Based Analysis A literature search was conducted from January 2003 to January 2009 that included OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), The Cochrane Library, and the International Agency for Health Technology Assessment/Centre for Review and Dissemination. Inclusion Criteria Exclusion Criteria adult patients with age-related cataractssystematic reviews, randomized controlled trials (RCTs)primary outcomes: distance visual acuity (best corrected distance visual acuity), near visual acuity (best distance corrected near visual acuity)secondary outcomes: contrast sensitivity, depth of field, glare, quality of life, visual function, spectacle dependence, posterior capsule opacification. studies with fewer than 20 eyesIOLs for non-age related cataractsIOLs for presbyopiastudies with a mean follow-up <6monthsstudies reporting insufficient data for analysis Comparisons of Interest The primary comparison of interest was accommodative vs. multifocal vs. monofocal lenses. Secondary comparisons of interest included: tinted vs. non-tinted lenses aspheric vs. spheric lenses multipiece vs. single piece lenses biomaterial A (e.g. acrylic) vs. biomaterial B (e.g. silicone) lenses sharp vs. round edged lenses The quality of the studies was examined according to the GRADE Working Group criteria for grading quality of evidence for interventional procedures. Summary of Findings The conclusions of the systematic review of IOLs for age-related cataracts are summarized in Executive Summary Table 1. Considerations for the Ontario Health System Procedures for crystalline lens removal and IOL insertion are insured and listed in the Ontario Schedule of Benefits. If a particular lens is determined to be medically necessary for a patient, the cost of the lens is covered by the hospital budget. If the patient chooses a lens that has enhanced features, then the hospital may choose to charge an additional amount above the cost of the usual lens offered. An IOL manufacturer stated that monofocal lenses comprise approximately 95% of IOL sales in Ontario and premium lenses (e.g., multifocal/accomodative) consist of about 5% of IOL sales. A medical consultant stated that all types of lenses are currently being used in Ontario (e.g., multifocal, monofocal, accommodative, tinted, nontinted, spheric, and aspheric). Nonfoldable lenses, rarely used in routine cases, are primarily used for complicated cataract implantation situations. ES Table 1: Conclusions for the Systematic Review of IOLs for Age-Related Cataracts Comparison Conclusion GRADE Quality Multifocal vs. monofocal Objective OutcomesSignificant improvement in BDCUNVANo significant difference in BCDVAInconclusive evidence for contrast sensitivityInconclusive evidence for glareSubjective OutcomesInconclusive evidence for visual satisfactionSignificant increase in glare/halosSignificant increase in freedom from spectacles moderatemoderatelowvery lowlowlow/moderatelow/moderate Accommodative vs. multifocal/monofocal Inconclusive due to Insufficient limited evidence for any effectiveness outcome very low Hydrophilic acrylic vs. other materials (hydrophobic acrylic, silicone) Significant increase in PCO score Low Sharp edged compared to round edged Significant reduction in PCO score Low One piece compared to three piece No significant difference in PCO score low Hydrophobic acrylic compared to silicone No significant difference in PCO score moderate Aspherical modified prolate anterior surface compared to spherical No significant difference in VASignificant reduction in contrast sensitivity very lowvery low Blue light filtering compared to non blue-light filtering No significant difference in BCDVANo significant difference in contrast sensitivityNo significant difference in HRQL lowlowhigh/moderate BCDVA refers to best corrected distance visual acuity; BDCUNVA, best distance corrected unaided near visual acuity; HRQL, health related quality of life; PCO, posterior capsule opacification; VA, visual acuity. PMID:23074519
Multifocal recurrent periostitis. Report of two cases.
Kozlowski, K; Anderson, R; Tink, A
1981-11-01
Two case reports of recurrent multifocal periostitis in two girls aged 15 and 6 are added to the eight cases already reported in the literature. The disease is characterized clinically by recurrent mesomelic swelling of the extremities and radiologically by periosteal thickening and sclerosis of underlying bone. Hyperglobulinaemia is the most constant biochemical finding. The bone biopsy shows no typical features. The possibility of a viral etiology is discussed.
Multifocal recurrent periostitis responsive to colchicine.
Festen, J J; Kuipers, F C; Schaars, A H
1985-01-01
A brother and sister with multifocal recurrent periostitis are presented. Their disease started at an early age and manifested itself as an episodic migrating arthropathy. At roentgenography, reversible solid periosteal reactions were visible along large tubular bones. Scintigraphic and histological investigations revealed a sterile osteitis and thickened periosteum, but there was no indication of a viral infection. The girl experienced spontaneous amelioration after puberty; the boy improved markedly on colchicine.
Ishigaki, Hidetoshi; Hiraide, Takuya; Miyagi, Yoshifumi; Hayashi, Taiju; Matsubayashi, Tomoko; Shimoda, Ayumi; Kusunoki, Susumu; Fukuda, Tokiko
2016-09-01
Multifocal motor neuropathy is a rare immune-mediated neuropathy characterized by progressive asymmetric weakness and atrophy without sensory abnormalities. Although disease onset is usually in adulthood, a few childhood-onset cases have been reported. Here, we report the case of an 8-year-old boy with multifocal motor neuropathy who presented with a slowly progressive left and distal upper limb weakness without sensory loss. The initial high-dose intravenous immunoglobulin treatment significantly improved left upper limb muscle weakness. Continued monthly intravenous immunoglobulin treatment gradually improved muscle strength for several months initially. While the muscle strength decreased slightly after 8 months of therapy, it was better than that before intravenous immunoglobulin treatment. One year and eight months after the initiation of treatment, serum testing for IgM antibodies to gangliosides, GM1 and GM2, was negative. This is the first pediatric report of the serum IgM autoantibodies positive to GM1 and GM2. The clinical course is similar to that of partial intravenous immunoglobulin responders among patients with adulthood-onset multifocal motor neuropathy. Since the symptoms plateaued after the initial intravenous immunoglobulin therapy, prognosis appears to be determined by the patient's initial response to intravenous immunoglobulin treatment. Copyright © 2016 Elsevier Inc. All rights reserved.
Multifocal Intraocular Lens Results in Correcting Presbyopia in Eyes After Radial Keratotomy.
Kim, Kyeong Hwan; Seok, Kyung-Won; Kim, Wan Soo
2017-11-01
To report results of multifocal intraocular lens (IOL) implantation in 2 patients with refractive error and presbyopia after previous radial keratotomy (RK). A refractive multifocal IOL with rotational asymmetry (LS313-MF30; Oculentis, Berlin, Germany) was implanted. The first patient was a 60-year-old man with myopia who underwent unilateral RK 20 years before. His uncorrected distance visual acuity (UDVA) was 20/400, and his distance corrected near vision was J9 in both eyes. Six months after bilateral surgery, his binocular UDVA and uncorrected near visual acuity (UNVA) improved to 20/20 and J1, respectively, although he experienced diurnal fluctuation. The second patient was a 55-year-old woman with hyperopia who underwent bilateral RK 18 years before. Uncorrected distance visual acuity was 20/25 in both eyes, but UNVA was between J9 and J10. Three months after unilateral surgery, UDVA and UNVA of the postsurgical eye improved to 20/20 and J1, respectively. Neither patient reported any significant photic phenomena, and both were satisfied with the results of treatment. The desirable clinical outcomes and levels of satisfaction expressed by these patients indicate that surgery using this particular multifocal IOL may benefit presbyopic patients with previous RK.
[Multifocal Electroretinography in Patients with Poppers Maculopathy].
Pahlitzsch, Milena; Salchow, Daniel; Rossel, Mirjam; Bergholz, Richard
2017-10-12
Background Maculopathy is a potential side effect of amyl nitrite or "poppers" abuse. It is characterized by a sudden, painless decrease in visual acuity. While the funduscopic changes are subtle, optical coherence tomography shows alterations of the outer retinal layers in the fovea. However, the extent of retinal dysfunction remains poorly understood. Materials/Methods We compared the multifocal electroretinogram of 6 patients with poppers maculopathy to that of a control group consisting of 6 healthy subjects. Response densities and implicit times of N1 and P1 were analyzed. Results Response densities and implicit times of both N1 and P1 were lower in the patients with poppers maculopathy than in the control group, particularly in ring 1 and rings 4 and 5. The only statistically significant finding, however, was a reduced N1 response density of one hexagon in the patient group. No significant differences were found considering the sum response or the averaged rings 1 to 5. Conclusion Compared to a healthy control group, the multifocal electroretinogram of patients with poppers maculopathy shows no relevant impairment. This contrasts the marked effect of the disease on visual acuity. In clinical practice, poppers maculopathy cannot be diagnosed by multifocal electroretinography. Georg Thieme Verlag KG Stuttgart · New York.
Dolz-Marco, Rosa; Sarraf, David; Giovinazzo, Vincent; Freund, K Bailey
2017-01-01
To describe multimodal imaging findings of an evolving case of acute posterior multifocal placoid pigment epitheliopathy occurring in a young healthy male. Case report of a patient with acute posterior multifocal placoid pigment epitheliopathy including comprehensive systemic and ocular examinations. Ultra-widefield autofluorescence, fluorescein angiography, indocyanine green angiography, and serial optical coherence tomography angiography were performed. A 34-year-old male presented with acute vision loss in his left eye for 2 weeks. His best-corrected visual acuity was 20/20 in his right eye and 20/200 in his left eye. Dilated funduscopic examination revealed multiple creamy white deep retinal lesions showing macular involvement of the left eye with a diffuse area of pigmentary changes. The presence of multiple areas of hypoperfusion of the inner choroid were demonstrated with fluorescein and indocyanine green angiography. Serial optical coherence tomography angiography showed multiple evolving areas of decreased flow at the level of the inner choroid. Although the pathogenesis of acute posterior multifocal placoid pigment epitheliopathy remains unknown, there is growing evidence of a primary choroidal involvement with secondary damage to the overlying retinal pigment epithelium and the outer retinal layers. Optical coherence tomography angiography may provide valuable information for the diagnosis and follow-up of this condition avoiding invasive angiographic procedures.
Naik, Mayuresh P; Mehta, Anuj; Abrol, Sangeeta; Kumar, Sandeep; Gupta, Vishnu S
2016-12-01
To determine the safety and efficacy of topical 5-fluorouracil (5-FU) 5% ointment in treatment of non-syndromic multifocal basal cell carcinoma. A 55-year-old male patient, with 8 hours of daily sun exposure, having histologically proven and radiologically non-syndromic, multifocal basal cell carcinoma with involvement of 6 sites on the face, was treated with topical 5-FU 5% ointment twice daily over all sites except the site involving lid margin to prevent corneal toxicity. Left lid lesion underwent wide surgical excision with 5-mm clear margins and reconstruction with nasal septal mucoperichondrium and local skin mobilization. Pharmacologic effects first appeared at 4 weeks and by 8 weeks, the lesions had scabbed and had fallen off with no induration but residual mild perilesional erythema. Patient had post-op histopathological clear margins and recovered uneventfully. No recurrence in 6 months. A topical 5-FU 5% ointment represents a paradigm shift in the treatment of BCC from invasive and disfiguring options (surgery and chemoradiotherapy) to cheap, convenient, effective, non-invasive, non-disfiguring topical chemotherapy. Topical 5% 5-FU is a safe and effective modality of treatment of superficial spreading multifocal basal carcinoma, especially lesions larger than 10 mm, where margins cannot be identified clearly and recurrent lesions.
Speckle-based three-dimensional velocity measurement using spatial filtering velocimetry.
Iversen, Theis F Q; Jakobsen, Michael L; Hanson, Steen G
2011-04-10
We present an optical method for measuring the real-time three-dimensional (3D) translational velocity of a diffusely scattering rigid object observed through an imaging system. The method is based on a combination of the motion of random speckle patterns and regular fringe patterns. The speckle pattern is formed in the observation plane of the imaging system due to reflection from an area of the object illuminated by a coherent light source. The speckle pattern translates in response to in-plane translation of the object, and the presence of an angular offset reference wave coinciding with the speckle pattern in the observation plane gives rise to interference, resulting in a fringe pattern that translates in response to the out-of-plane translation of the object. Numerical calculations are performed to evaluate the dynamic properties of the intensity distribution and the response of realistic spatial filters designed to measure the three components of the object's translational velocity. Furthermore, experimental data are presented that demonstrate full 3D velocity measurement. © 2011 Optical Society of America
Students’ understanding of forces: Force diagrams on horizontal and inclined plane
NASA Astrophysics Data System (ADS)
Sirait, J.; Hamdani; Mursyid, S.
2018-03-01
This study aims to analyse students’ difficulties in understanding force diagrams on horizontal surfaces and inclined planes. Physics education students (pre-service physics teachers) of Tanjungpura University, who had completed a Basic Physics course, took a Force concept test which has six questions covering three concepts: an object at rest, an object moving at constant speed, and an object moving at constant acceleration both on a horizontal surface and on an inclined plane. The test is in a multiple-choice format. It examines the ability of students to select appropriate force diagrams depending on the context. The results show that 44% of students have difficulties in solving the test (these students only could solve one or two items out of six items). About 50% of students faced difficulties finding the correct diagram of an object when it has constant speed and acceleration in both contexts. In general, students could only correctly identify 48% of the force diagrams on the test. The most difficult task for the students in terms was identifying the force diagram representing forces exerted on an object on in an inclined plane.
Evanescent-Wave Filtering in Images Using Remote Terahertz Structured Illumination
NASA Astrophysics Data System (ADS)
Flammini, M.; Pontecorvo, E.; Giliberti, V.; Rizza, C.; Ciattoni, A.; Ortolani, M.; DelRe, E.
2017-11-01
Imaging with structured illumination allows for the retrieval of subwavelength features of an object by conversion of evanescent waves into propagating waves. In conditions in which the object plane and the structured-illumination plane do not coincide, this conversion process is subject to progressive filtering of the components with high spatial frequency when the distance between the two planes increases, until the diffraction-limited lateral resolution is restored when the distance exceeds the extension of evanescent waves. We study the progressive filtering of evanescent waves by developing a remote super-resolution terahertz imaging system operating at a wavelength λ =1.00 mm , based on a freestanding knife edge and a reflective confocal terahertz microscope. In the images recorded with increasing knife-edge-to-object-plane distance, we observe the transition from a super-resolution of λ /17 ≃60 μ m to the diffraction-limited lateral resolution of Δ x ≃λ expected for our confocal microscope. The extreme nonparaxial conditions are analyzed in detail, exploiting the fact that, in the terahertz frequency range, the knife edge can be positioned at a variable subwavelength distance from the object plane. Electromagnetic simulations of radiation scattering by the knife edge reproduce the experimental super-resolution achieved.
Fire Protection Informational Exchange
2016-07-01
0.95 L/min concurrent spray & 274x521 mm pool (66°C) i. Persistent fuels; turbine fuel in spray/pool; lubricant, hydraulic fluid in spray ii...conjugate image plane La Vision sCMOS + Kl long- distance microscope with CF4 objective wire .. " " " " ... in-line hologram image plane La...distance microscope with CF4 objective wire I phase disrurbanc.e (f= 2000 nun) .. " " " " ... in-line hologram image plane La Vision sCNlOS
Disease progression and recurrence in women treated for vulvovaginal intraepithelial neoplasia
Baumann, Marc; Mueller, Michael; Fink, Daniel; Heinzl, Siegfried; Imesch, Patrick; Dedes, Konstantin
2013-01-01
Objective The malignant potential of intraepithelial neoplasia of the vulva and vagina after treatment is not well defined. Our objective was to examine risk factors for recurrence and invasive disease. Methods Four hundred sixty-four women with biopsy proven high-grade intraepithelial neoplasia of the vulva and vagina were identified in the electronic databases of four colposcopy clinics. Inclusion criteria were a follow-up of more than one year, no history of invasive cancer and no invasive cancer within the first year after initial treatment. We investigated the potential factors associated with recurrence and progression using a logistic regression analysis to estimate odds ratios (ORs) and 95% confidence intervals (CIs). Results Of the 411 eligible patients, 123 patients (29.9%) recurred later than one year after initial treatment and 24 patients (5.8%) progressed to invasive disease. According to multivariate analyses, the risk factors associated with recurrence were multifocality (OR, 3.33; 95% CI, 2.02 to 5.51), immunosuppression (OR, 2.51; 95% CI, 1.09 to 5.81), excision as initial treatment (vs. laser evaporation; OR, 1.79; 95% CI, 1.11 to 2.91) and smoking (OR, 1.61; 95% CI, 1.02 to 2.55). Risk factors for progression to invasive disease were immunosuppression (OR, 4.00; 95% CI, 1.30 to 12.25), multifocality (OR, 3.05; 95% CI, 1.25 to 7.43) and smoking (OR, 2.97; 95% CI, 1.16 to 7.60), but not treatment modality. Conclusion Laser evaporation combined with extensive biopsy is at least as efficacious as initial treatment of intraepithelial neoplasia with excision. Smoking is a risk factor for both recurrence and progression to invasive disease. Hence, smoking cessation should be advised and maintaining a long follow-up period due to late relapses is necessary. PMID:23875073
Spatial filtering velocimetry of objective speckles for measuring out-of-plane motion.
Jakobsen, M L; Yura, H T; Hanson, S G
2012-03-20
This paper analyzes the dynamics of objective laser speckles as the distance between the object and the observation plane continuously changes. With the purpose of applying optical spatial filtering velocimetry to the speckle dynamics, in order to measure out-of-plane motion in real time, a rotational symmetric spatial filter is designed. The spatial filter converts the speckle dynamics into a photocurrent with a quasi-sinusoidal response to the out-of-plane motion. The spatial filter is here emulated with a CCD camera, and is tested on speckles arising from a real application. The analysis discusses the selectivity of the spatial filter, the nonlinear response between speckle motion and observation distance, and the influence of the distance-dependent speckle size. Experiments with the emulated filters illustrate performance and potential applications of the technology. © 2012 Optical Society of America
NASA Technical Reports Server (NTRS)
Minott, P. O. (Inventor)
1983-01-01
Two mutually coherent light beams formed from a single monochromatic light source were directed to a reflecting surface of a rotatable object. They were reflected into an imaging optical lens having a focal plane optically at infinity. A series of interference fringes were formed in the focal plane which were translated linearly in response to angular rotation of the object. Photodetectors were located adjacent the focal plane to detect the fringe translation and output a signal in response to the translation. The signal was fed to a signal processor which was adapted to count the number of fringes detected and develop a measure of the angular rotation and direction of the object.
Multifocal intraocular lenses: Types, outcomes, complications and how to solve them
Salerno, Liberdade C.; Tiveron, Mauro C.; Alió, Jorge L.
2017-01-01
The multifocal intraocular lenses (IOLs) available are often able to restore visual function and allow spectacle independence after their implantation with great levels of patient satisfaction. The factors associated with the postoperatory success include the careful selection of the patient, the knowledge about the IOLs’ design, and their visual performance added to the proper surgical technique and management of possible complications as demonstrated by the evidence available. PMID:29296549
Chest wall resection for multifocal osseous haemangioma.
Weinandt, Marthe; Legras, Antoine; Mordant, Pierre; Le Pimpec Barthes, Françoise
2016-02-01
Intraosseous haemangioma is a rare and benign primary tumour of the bone. We report the case of a 76-year old woman who presented the exceptional condition of multifocal cavernous haemangiomas involving the spine and the ribs, requiring spinal and chest wall resections to confirm the diagnosis and treat the symptoms. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Wislez, Marie; Cadranel, Jacques; Milleron, Bernard
2003-04-01
Bronchoalveolar carcinoma is one of the four histologic subtypes of adenocarcinoma and its incidence is increasing. It grows in a lepidic fashion along the alveolar septa without invasive growth. The lack of invasive growth is an essential criterion based on data indicating that patients may be curable by surgical resection. The revised definition seems to be suitable for its solitary nodular form but less for multifocal or pneumonic-type form. High-resolution lung CT-scan is necessary to evaluate pulmonary involvement because of the high frequency of multifocal disease at initial presentation and because of the presence of ground glass opacity that could be one of the first manifestation of cancer bronchiolo-alvéolaireon CT. Therapeutic management does not differ from the one of non small cell lung cancer. Solitary nodules are treated by surgical resection with a good prognosis while multifocal and/or pneumonic forms are treated by systemic chemotherapy with a worse prognosis.
Dantas, Thinali Sousa; Nascimento, Isabelly Vidal do; Verde, Maria Elisa Quezado Lima; Alves, Ana Paula Negreiros Nunes; Sousa, Fabrício Bitu; Mota, Mário Rogério Lima
2017-01-01
Oral melanoacanthoma is a mucocutaneous, pigmented, rare, benign, and probably reactive lesion. This paper reports for the first time in the literature a case of multifocal oral melanoacanthoma in a patient diagnosed with Addison's disease and concomitant Graves' disease with hyperthyroidism. The patient presented with oral pigmented lesions, which were hypothesized to be mucosal pigmentation associated with Addison's disease. Due to their unusual clinical pattern, these oral lesions were biopsied and diagnosed as oral melanoacanthoma on histopathology and immunohistochemistry for HMB-45. At the moment of this report, the patient was being treated for her systemic conditions, but the lesions had not regressed. Reactive hyperpigmentation of the skin and mucous membranes may be found in Addison's disease and hyperthyroidism. This case reinforces the hypothesis of a reactive nature for oral melanoacanthoma and highlights the need for investigation of endocrine disorders in patients with multifocal oral melanoacanthoma.
Nakagawa, Shunsuke; Shinkoda, Yuichi; Hazeki, Daisuke; Imamura, Mari; Okamoto, Yasuhiro; Kawakami, Kiyoshi; Kawano, Yoshifumi
2016-07-01
Central diabetes insipidus (CDI) and relapse are frequently seen in multifocal Langerhans cell histiocytosis (LCH). We present two females with multifocal LCH who developed CDI 9 and 5 years after the initial diagnosis, respectively, as a relapse limited to the pituitary stalk. Combination chemotherapy with cytarabine reduced the mass in the pituitary stalk. Although CDI did not improve, there has been no anterior pituitary hormone deficiency (APHD), neurodegenerative disease in the central nervous system (ND-CNS) or additional relapse for 2 years after therapy. It was difficult to predict the development of CDI in these cases. CDI might develop very late in patients with multifocal LCH, and therefore strict follow-up is necessary, especially with regard to symptoms of CDI such as polydipsia and polyuria. For new-onset CDI with LCH, chemotherapy with cytarabine might be useful for preventing APHD and ND-CNS.
Multifocal visual evoked potentials for early glaucoma detection.
Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W
2012-07-01
To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.
Plane Transformations in a Complex Setting II: Isometries
ERIC Educational Resources Information Center
Dana-Picard, Thierry
2007-01-01
This paper is the second part of a study of plane transformations using a complex setting. The first part was devoted to homotheties and translations, now attention is turned towards plane isometries. The group theoretic properties of plane isometries are easy to derive and images of classical geometrical objects by these transformations are…
Neural-Network Object-Recognition Program
NASA Technical Reports Server (NTRS)
Spirkovska, L.; Reid, M. B.
1993-01-01
HONTIOR computer program implements third-order neural network exhibiting invariance under translation, change of scale, and in-plane rotation. Invariance incorporated directly into architecture of network. Only one view of each object needed to train network for two-dimensional-translation-invariant recognition of object. Also used for three-dimensional-transformation-invariant recognition by training network on only set of out-of-plane rotated views. Written in C language.
Donoho, David L.
1999-01-01
For each pair (n, k) with 1 ≤ k < n, we construct a tight frame (ρλ : λ ∈ Λ) for L2 (Rn), which we call a frame of k-plane ridgelets. The intent is to efficiently represent functions that are smooth away from singularities along k-planes in Rn. We also develop tools to help decide whether k-plane ridgelets provide the desired efficient representation. We first construct a wavelet-like tight frame on the X-ray bundle χn,k—the fiber bundle having the Grassman manifold Gn,k of k-planes in Rn for base space, and for fibers the orthocomplements of those planes. This wavelet-like tight frame is the pushout to χn,k, via the smooth local coordinates of Gn,k, of an orthonormal basis of tensor Meyer wavelets on Euclidean space Rk(n−k) × Rn−k. We then use the X-ray isometry [Solmon, D. C. (1976) J. Math. Anal. Appl. 56, 61–83] to map this tight frame isometrically to a tight frame for L2(Rn)—the k-plane ridgelets. This construction makes analysis of a function f ∈ L2(Rn) by k-plane ridgelets identical to the analysis of the k-plane X-ray transform of f by an appropriate wavelet-like system for χn,k. As wavelets are typically effective at representing point singularities, it may be expected that these new systems will be effective at representing objects whose k-plane X-ray transform has a point singularity. Objects with discontinuities across hyperplanes are of this form, for k = n − 1. PMID:10051554
Wisneski, Kimberly J; Johnson, Michelle J
2007-03-23
Robotic therapy is at the forefront of stroke rehabilitation. The Activities of Daily Living Exercise Robot (ADLER) was developed to improve carryover of gains after training by combining the benefits of Activities of Daily Living (ADL) training (motivation and functional task practice with real objects), with the benefits of robot mediated therapy (repeatability and reliability). In combining these two therapy techniques, we seek to develop a new model for trajectory generation that will support functional movements to real objects during robot training. We studied natural movements to real objects and report on how initial reaching movements are affected by real objects and how these movements deviate from the straight line paths predicted by the minimum jerk model, typically used to generate trajectories in robot training environments. We highlight key issues that to be considered in modelling natural trajectories. Movement data was collected as eight normal subjects completed ADLs such as drinking and eating. Three conditions were considered: object absent, imagined, and present. This data was compared to predicted trajectories generated from implementing the minimum jerk model. The deviations in both the plane of the table (XY) and the sagittal plane of torso (XZ) were examined for both reaches to a cup and to a spoon. Velocity profiles and curvature were also quantified for all trajectories. We hypothesized that movements performed with functional task constraints and objects would deviate from the minimum jerk trajectory model more than those performed under imaginary or object absent conditions. Trajectory deviations from the predicted minimum jerk model for these reaches were shown to depend on three variables: object presence, object orientation, and plane of movement. When subjects completed the cup reach their movements were more curved than for the spoon reach. The object present condition for the cup reach showed more curvature than in the object imagined and absent conditions. Curvature in the XZ plane of movement was greater than curvature in the XY plane for all movements. The implemented minimum jerk trajectory model was not adequate for generating functional trajectories for these ADLs. The deviations caused by object affordance and functional task constraints must be accounted for in order to allow subjects to perform functional task training in robotic therapy environments. The major differences that we have highlighted include trajectory dependence on: object presence, object orientation, and the plane of movement. With the ability to practice ADLs on the ADLER environment we hope to provide patients with a therapy paradigm that will produce optimal results and recovery.
ERIC Educational Resources Information Center
Houlrik, Jens Madsen
2009-01-01
The Lorentz transformation applies directly to the kinematics of moving particles viewed as geometric points. Wave propagation, on the other hand, involves moving planes which are extended objects defined by simultaneity. By treating a plane wave as a geometric object moving at the phase velocity, novel results are obtained that illustrate the…
King, R R; Reiss, J P
2012-01-01
Pseudobulbar affect (PBA) manifests in a variety of neurologic illnesses suggesting a heterogeneous pathophysiology with common underpinnings. We report successful treatment of PBA with a selective serotonin reuptake inhibitor (SSRI) in a 54-year-old woman following progressive multifocal leukoencephalopathy (PML). In light of recent focus on dextromethorphan/quinidine (DM/Q) for the treatment of PBA, the clinician is reminded of the effectiveness of SSRIs. Copyright © 2011 Elsevier Ltd. All rights reserved.
Atla, Bhagyalakshmi; Sudhakar, P V; Rao, Nagarjun; Prasad, Uma
2016-01-01
Kaposiform hemangioendothelioma (KHE) is a locally aggressive vascular tumor of childhood although cases occurring in adulthood are also described. The features overlap with juvenile capillary hemangioma and Kaposi sarcoma. We report a rare case of recurrent, multifocal (nose and chin) cutaneous KHE initially occurring in a 3-year-old female child, uncomplicated by Kasabach-Merritt syndrome. Recurrences occurred over the next 6 years and resulted in complete distortion of the nose, requiring plastic repair.
Navarro, Rodrigo M.; Machado, Leonardo M.; Maia, Ossires; Wu, Lihteh; Farah, Michel E.; Magalhaes, Octaviano; Arevalo, J. Fernando; Maia, Mauricio
2015-01-01
Purpose. To determine the efficacy of 23-gauge pars plana vitrectomy (PPV) for symptomatic posterior vitreous detachment (PVD) on visual acuity (VA) and quality after multifocal intraocular lenses (IOLs). Methods. In this prospective case series, patients who developed symptomatic PVD and were not satisfied with visual quality due to floaters and halos after multifocal IOL implantation underwent PPV. Examinations included LogMAR uncorrected visual acuity (UCVA), intraocular pressure, biomicroscopy, and indirect ophthalmoscopy at baseline and 1, 7, 30, and 180 days postoperatively. Ultrasonography and aberrometry were performed. The Visual Functioning Questionnaire 25 (VFQ-25) was administered preoperatively and at 30 days postoperatively. Both the postoperative UCVA and questionnaire results were compared to preoperative findings using the Wilcoxon test. Results. Sixteen eyes of 8 patients were included. VA significantly improved from 0.17 to 0.09 postoperatively (P = 0.017). All patients reported improvement of halos, glare, and floaters. VFQ-25 scores significantly improved in general vision (P = 0.023), near activities (P = 0.043), distance activities (P = 0.041), mental health (P = 0.011), role difficulties (P = 0.042), and driving (P = 0.016). Conclusion. PPV may increase UCVA and quality of vision in patients with bilateral multifocal IOLs and symptomatic PVD. Larger studies are advised. PMID:26504590
Atypical multifocal Dravet syndrome lacks generalized seizures and may show later cognitive decline.
Kim, Young Ok; Bellows, Susannah; McMahon, Jacinta M; Iona, Xenia; Damiano, John; Dibbens, Leanne; Kelley, Kent; Gill, Deepak; Cross, J Helen; Berkovic, Samuel F; Scheffer, Ingrid E
2014-01-01
To show that atypical multifocal Dravet syndrome is a recognizable, electroclinical syndrome associated with sodium channel gene (SCN1A) mutations that readily escapes diagnosis owing to later cognitive decline and tonic seizures. Eight patients underwent electroclinical characterization. SCN1A was sequenced and copy number variations sought by multiplex ligation-dependent probe amplification. All patients were female (age range at assessment 5-26y) with median seizure onset at 6.5 months (range 4-19mo). The initial seizure was brief in seven and status epilepticus only occurred in one; three were febrile. Focal seizures occurred in four patients and bilateral convulsion in the other four. All patients developed multiple focal seizure types and bilateral convulsions, with seizure clusters in six. The most common focal seizure semiology (six out of eight) comprised unilateral clonic activity. Five also had focal or asymmetric tonic seizures. Rare or transient myoclonic seizures occurred in six individuals, often triggered by specific antiepileptic drugs. Developmental slowing occurred in all: six between 3 years and 8 years, and two around 1 year 6 months. Cognitive outcome varied from severe to mild intellectual disability. Multifocal epileptiform discharges were seen on electroencephalography. Seven out of eight patients had SCN1A mutations. Atypical, multifocal Dravet syndrome with SCN1A mutations may not be recognized because of later cognitive decline and frequent tonic seizures. © 2013 Mac Keith Press.
Chuang, Jody C.; Shrager, Joseph B.; Wakelee, Heather A.; Neal, Joel W.
2016-01-01
Purpose Adenocarcinoma remains the most common subtype of lung cancer in the United States. Most patients present with tumors that are invasive and often metastatic, but some patients develop multiple precursor in-situ or minimally invasive adenocarcinoma tumors which can be synchronous and metachronous. These precursor lesions harbor the same spectrum of genetic mutations found in pure-invasive adenocarcinomas, such as EGFR, KRAS and p53 mutations. It is less clear, however, if separate lesions in patients who present with multifocal disease share common underlying genetic driver mutations. Methods Here we review the relevant literature on molecular driver alterations in adenocarcinoma precursor lesions. We then report four cases with multifocal EGFR mutant adenocarcinomas in whom we performed molecular testing on 2 separate lesions. Findings In two of these patients, the mutations are concordant, and in two cases the mutations are discordant. A review of the literature demonstrates increasing evidence that lesions with discordant mutations may confer a more favorable prognosis, since they are unlikely to represent metastases. Implications Our findings suggest that the emergence of the dominant EGFR driver alteration is often independent between lesions in patients with multifocal adenocarcinomas, and thus the same targeted therapy may not be effective for all lesions. However, genetic testing of multiple lesions can help distinguish separate primary tumors from metastatic disease. PMID:27368115
A Randomized Trial of Soft Multifocal Contact Lenses for Myopia Control: Baseline Data and Methods.
Walline, Jeffrey J; Gaume Giannoni, Amber; Sinnott, Loraine T; Chandler, Moriah A; Huang, Juan; Mutti, Donald O; Jones-Jordan, Lisa A; Berntsen, David A
2017-09-01
The Bifocal Lenses In Nearsighted Kids (BLINK) study is the first soft multifocal contact lens myopia control study to compare add powers and measure peripheral refractive error in the vertical meridian, so it will provide important information about the potential mechanism of myopia control. The BLINK study is a National Eye Institute-sponsored, double-masked, randomized clinical trial to investigate the effects of soft multifocal contact lenses on myopia progression. This article describes the subjects' baseline characteristics and study methods. Subjects were 7 to 11 years old, had -0.75 to -5.00 spherical component and less than 1.00 diopter (D) astigmatism, and had 20/25 or better logMAR distance visual acuity with manifest refraction in each eye and with +2.50-D add soft bifocal contact lenses on both eyes. Children were randomly assigned to wear Biofinity single-vision, Biofinity Multifocal "D" with a +1.50-D add power, or Biofinity Multifocal "D" with a +2.50-D add power contact lenses. We examined 443 subjects at the baseline visits, and 294 (66.4%) subjects were enrolled. Of the enrolled subjects, 177 (60.2%) were female, and 200 (68%) were white. The mean (± SD) age was 10.3 ± 1.2 years, and 117 (39.8%) of the eligible subjects were younger than 10 years. The mean spherical equivalent refractive error, measured by cycloplegic autorefraction was -2.39 ± 1.00 D. The best-corrected binocular logMAR visual acuity with glasses was +0.01 ± 0.06 (20/21) at distance and -0.03 ± 0.08 (20/18) at near. The BLINK study subjects are similar to patients who would routinely be eligible for myopia control in practice, so the results will provide clinical information about soft bifocal contact lens myopia control as well as information about the mechanism of the treatment effect, if one occurs.
Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel
2015-03-01
To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P = .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Multifocal fibrosing thyroiditis: report of 55 cases of a poorly recognized entity.
Fellegara, Giovanni; Rosai, Juan
2015-03-01
During the course of our consultation activity, we have recognized a peculiar form of thyroiditis in which multiple foci of fibrosis, most of which were associated with reactive atypia of the surrounding follicles, are present. We have referred to this condition, both in our consultation reports and in the third series of A.F.I.P. Fascicle on Tumors of the Thyroid Gland, as "multifocal fibrosing thyroiditis" or (less frequently) "multifocal sclerosing thyroiditis," which are descriptive terms that highlight the benign/inflammatory nature of the process, its multiplicity, and its unknown pathogenesis. The aim of this study is to better define the morphologic features of this process and correlate it with some clinical data. With this purpose, the consultation files of one of the authors (J.R.) were searched for cases coded as multifocal fibrosing thyroiditis or multifocal sclerosing thyroiditis in a 20-year period ranging from January 1989 to December 2009. A total of 55 cases were identified that displayed the above-listed features. There were 51 (93%) female and 4 (7%) male patients (F/M=12.75), with ages ranging between 15 and 71 years (mean age, 47.03 y; median age, 44.5 y). Microscopically, multiple foci of fibrosis were identified in all cases, their number ranging from 2 to 51 per case (mean number, 16), with a mean diameter of 3 mm (range: 0.36 to 15.1 mm). Although heterogenous in shape and size, the individual foci were rather similar to each other in composition, being characterized by a fibrotic poorly cellular center that merged with a cellular peripheral zone. Some of the follicular structures present at the periphery of the scar and-to a lesser extent-those entrapped inside it underwent complex reactive and regenerative (atypical) changes that simulated malignancy. We discuss the differential diagnosis with other benign and malignant thyroid conditions and speculate about its pathogenesis and possible relationship with papillary thyroid microcarcinoma.
Multi-focal multiphoton lithography.
Ritschdorff, Eric T; Nielson, Rex; Shear, Jason B
2012-03-07
Multiphoton lithography (MPL) provides unparalleled capabilities for creating high-resolution, three-dimensional (3D) materials from a broad spectrum of building blocks and with few limitations on geometry, qualities that have been key to the design of chemically, mechanically, and biologically functional microforms. Unfortunately, the reliance of MPL on laser scanning limits the speed at which fabrication can be performed, making it impractical in many instances to produce large-scale, high-resolution objects such as complex micromachines, 3D microfluidics, etc. Previously, others have demonstrated the possibility of using multiple laser foci to simultaneously perform MPL at numerous sites in parallel, but use of a stage-scanning system to specify fabrication coordinates resulted in the production of identical features at each focal position. As a more general solution to the bottleneck problem, we demonstrate here the feasibility for performing multi-focal MPL using a dynamic mask to differentially modulate foci, an approach that enables each fabrication site to create independent (uncorrelated) features within a larger, integrated microform. In this proof-of-concept study, two simultaneously scanned foci produced the expected two-fold decrease in fabrication time, and this approach could be readily extended to many scanning foci by using a more powerful laser. Finally, we show that use of multiple foci in MPL can be exploited to assign heterogeneous properties (such as differential swelling) to micromaterials at distinct positions within a fabrication zone.
Kim, Hee-Jin; Lee, Jae-Jung; Lee, Phil Hyu
2009-01-01
Progressive multifocal leukoencephalopathy (PML) is a demyelinating disease of the central nervous system (CNS) caused by JC virus infection in oligodendrocytes, especially in patients with acquired immunodeficiency syndrome (AIDS). Movement disorders associated with PML are very rare. Here, we report a case of PML in an AIDS patient who presented with a cerebellar tremor, caused by lesions in the cerebellar outflow tract. A cerebellar tremor can be a rare clinical manifestation in patients with PML. PMID:24868366
Pandey, Amit; Bandivdekar, Karishma; Ramchandani, Suresh; Ramchandani, Sushama
2012-01-01
We present a case of a Human Immunodeficiency Virus (HIV) positive patient who was referred for retinal evaluation to rule out ophthalmic manifestations of Acquired Immunodeficiency Syndrome (AIDS). She complained of some disturbance in vision in both eyes. Fundus examination showed no abnormality. Perimetry, done to rule out optic nerve pathology, showed a left homonymous hemianopia. Magnetic Resonance Imaging (MRI) scan showed features of Progressive Multifocal Leukoencephalopathy (PML). She had no other neurological symptoms or signs.
Chatmethakul, Trassanee; Bhat, Ramachandra; Alkaabi, Maryam; Siddiqui, Abdul; Peevy, Keith; Zayek, Michael
2016-07-01
Multifocal and diffuse infantile hepatic hemangioendotheliomas commonly present with signs of high-output congestive heart failure. In addition, prolonged persistent pulmonary overcirculation eventually leads to the development of pulmonary hypertension at a later age. We report a 2-day old, full-term infant with multifocal, large infantile hepatic hemangioendothelioma, who presented with an early onset of pulmonary hypertension, managed successfully with supportive care and systemic therapy directed toward the involution of infantile hepatic hemangioendothelioma.
Multifocal amelanotic conjunctival melanoma and acquired melanosis sine pigmento.
Paridaens, A D; McCartney, A C; Hungerford, J L
1992-01-01
Clinical and histopathological features of four cases of multifocal amelanotic malignant melanoma of the conjunctiva in association with 'acquired melanosis sine pigmento' are reported. The absence of conjunctival pigmentation in this extremely rare combination of lesions prevented early diagnosis and clinical monitoring. As a result orbital exenteration was required in three cases. This multicentric non-pigmented variety of conjunctival malignant melanoma tends to present later than pigmented forms and may require exenteration of the orbit as a primary procedure. Images PMID:1540561
Multifocal amelanotic conjunctival melanoma and acquired melanosis sine pigmento.
Paridaens, A D; McCartney, A C; Hungerford, J L
1992-03-01
Clinical and histopathological features of four cases of multifocal amelanotic malignant melanoma of the conjunctiva in association with 'acquired melanosis sine pigmento' are reported. The absence of conjunctival pigmentation in this extremely rare combination of lesions prevented early diagnosis and clinical monitoring. As a result orbital exenteration was required in three cases. This multicentric non-pigmented variety of conjunctival malignant melanoma tends to present later than pigmented forms and may require exenteration of the orbit as a primary procedure.
Unique Case of Disseminated Plague With Multifocal Osteomyelitis.
Tovar Padua, Leidy; Kamali, Amanda; Kim, Hannah; Green, Nicole M; Civen, Rachel; Schwartz, Benjamin; Krogstad, Paul; Deville, Jaime; Yeganeh, Nava; Lugo, Debra; Baker, Amira; Soni, Priya; Cho, Catherine; Svircic, Natalia; Dry, Sarah; Seeger, Leanne; Lloyd, Jessica; Deukmedjian, Grace; Bowen, Richard; Hale, Gillian; Zaki, Sherif R; Mead, Paul; Nielsen-Saines, Karin
2017-09-01
Plague is a disease caused by Yersinia pestis. Septicemic and pneumonic plague have a high mortality rate if untreated. Here we describe the challenges of accurately diagnosing a nonfatal pediatric case of septicemic plague with involvement of multiple organs; to our knowledge, the first documented case of multifocal plague osteomyelitis. © The Author 2017. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Determining The Plane of The Kuiper Belt with OSSOS
NASA Astrophysics Data System (ADS)
Van Laerhoven, Christa; Kavelaars, J. J.; Volk, Kathryn; Gladman, Brett; Petit, Jean-Marc
2018-04-01
We present the OSSOS-based measurement of the semi-major axes dependent orientation of the Kuiper Belt plane. A Kuiper Belt object's (KBO's) inclination can be broken down into a forced component and a free component. The inclination and longitude of ascending node of the forced inclination define the 'forced plane,' the plane about which the KBO's inclination will precess. Secular theory predicts that this forced plane should depend on semi-major axis. For example, the nu18 secular resonance should create a significant warp in the forced planet near 40.5 au (Chiang and Choi 2008). Not predicted by secular theory is a warp in the distant Kuiper Belt (semi-major axes greater than 50 au) seen by Volk and Malhotra 2016 using KBOs from the Minor Planet Catalog. We investigate what the inclination distribution is for objects beyond Neptune as a function of semi-major axis using the OSSOS characterized sample. Through use of the OSSOS survey simulator we test various underlying orbital distributions and compare how the survey would have observed those populations to the actual observed sample. In particular, we test various widths for the inclination distribution about various local forcing planes for the kernel, stirred, and hot classical Kuiper Belt. We find that the forced plane in matches well with the expected forced plane from secular theory. Through most of the main Kuiper Belt (between the 3:2 and 2:1 resonances), we can reject both the ecliptic plane and the invariable plane as the true forced plane. Only as the expected secularly forced plane approaches the invariable plane does the invariable plane become non-rejectable. In the outer Kuiper Belt we reject the nominal mean-plane measured by Volk and Malhotra, but smaller warps are still allowed by the data.
NASA Astrophysics Data System (ADS)
Alejandro Juárez-Reyes, Salvador; Sosa-Sánchez, Citlalli Teresa; Silva-Ortigoza, Gilberto; de Jesús Cabrera-Rosas, Omar; Espíndola-Ramos, Ernesto; Ortega-Vidals, Paula
2018-03-01
Among the best known non-interferometric optical tests are the wire test, the Foucault test and Ronchi test with a low frequency grating. Since the wire test is the seed to understand the other ones, the aim of the present work is to do a thorough study of this test for a lens with symmetry of revolution and to do this study for any configuration of the object and detection planes where both planes could intersect: two, one or no branches of the caustic region (including the marginal and paraxial foci). To this end, we calculated the vectorial representation for the caustic region, and we found the analytical expression for the pattern; we report that the analytical pattern explicitly depends on the magnitude of a branch of the caustic. With the analytical pattern we computed a set of simulations of a dynamical adaptation of the optical wire test. From those simulations, we have done a thorough analysis of the topological structure of the pattern; so we explain how the multiple image formation process and the image collapse process take place for each configuration, in particular, when both the wire and the detection planes are placed inside the caustic region, which has not been studied before. For the first time, we remark that not only the intersections of the object and detection planes with the caustic are important in the change of pattern topology; but also the projection of the intersection between the caustic and the object plane mapped onto the detection plane; and the virtual projection of the intersection between the caustic and the detection plane mapped onto the object plane. We present that for the new configurations of the optical system, the wire image is curves of the Tschirnhausen’s cubic, the piriform and the deformed eight-curve types.
2010-08-09
44 9 A photograph of a goniophotometer used by Bell and a schematic of a goniophotometer used by Mian et al...plane is called the parallel field component because it lies parallel to the specular plane. The incident electric field vector component which...resides in the plane or- thogonal to the specular plane is called the perpendicular field component because it lies perpendicular to the specular plane. If
Multifocal electroretinography in patients with Stargardt's macular dystrophy
Kretschmann, U; Seeliger, M; Ruether, K; Usui, T; Apfelstedt-Sylla, E; Zrenner, E
1998-01-01
AIMS—To describe the topography of multifocal electroretinograms (ERGs) and to explore its diagnostic value in patients with Stargardt's macular dystrophy (SMD). METHODS—51 patients with SMD were examined by means of the m-sequence technique to characterise the topography of electroretinographic responses in the central visual field. The results were compared with data from 30 normal volunteers. RESULTS—In 49 of 51 patients with SMD, macular electroretinographic activity was markedly diminished or non-detectable. Towards more peripheral areas, ERG responses of the SMD patients approached those of normals. Implicit times were not markedly delayed at any eccentricity. CONCLUSION—In contrast with Ganzfeld electroretinography, multifocal electroretinography is useful to detect foveal dysfunction in SMD. Areas of dysfunction were found to be usually larger than expected from psychophysical measurements and morphological alteration. In early stages of the disease it was possible to detect foveal dysfunction, even in patients lacking morphological fundus changes and with good visual acuity. Keywords: Stargardt's macular dystrophy; fundus flavimaculatus; electroretinography PMID:9602623
Predictability of uncontrollable multifocal seizures - towards new treatment options
NASA Astrophysics Data System (ADS)
Lehnertz, Klaus; Dickten, Henning; Porz, Stephan; Helmstaedter, Christoph; Elger, Christian E.
2016-04-01
Drug-resistant, multifocal, non-resectable epilepsies are among the most difficult epileptic disorders to manage. An approach to control previously uncontrollable seizures in epilepsy patients would consist of identifying seizure precursors in critical brain areas combined with delivering a counteracting influence to prevent seizure generation. Predictability of seizures with acceptable levels of sensitivity and specificity, even in an ambulatory setting, has been repeatedly shown, however, in patients with a single seizure focus only. We did a study to assess feasibility of state-of-the-art, electroencephalogram-based seizure-prediction techniques in patients with uncontrollable multifocal seizures. We obtained significant predictive information about upcoming seizures in more than two thirds of patients. Unexpectedly, the emergence of seizure precursors was confined to non-affected brain areas. Our findings clearly indicate that epileptic networks, spanning lobes and hemispheres, underlie generation of seizures. Our proof-of-concept study is an important milestone towards new therapeutic strategies based on seizure-prediction techniques for clinical practice.
Evolving paradigms in multifocal breast cancer.
Salgado, Roberto; Aftimos, Philippe; Sotiriou, Christos; Desmedt, Christine
2015-04-01
The 7th edition of the TNM defines multifocal breast cancer as multiple simultaneous ipsilateral and synchronous breast cancer lesions, provided they are macroscopically distinct and measurable using current traditional pathological and clinical tools. According to the College of American Pathologists (CAP), the characterization of only the largest lesion is considered sufficient, unless the grade and/or histology are different between the lesions. Here, we review three potentially clinically relevant aspects of multifocal breast cancers: first, the importance of a different intrinsic breast cancer subtype of the various lesions; second, the emerging awareness of inter-lesion heterogeneity; and last but not least, the potential introduction of bias in clinical trials due to the unrecognized biological diversity of these cancers. Although the current strategy to assess the lesion with the largest diameter has clearly its advantages in terms of costs and feasibility, this recommendation may not be sustainable in time and might need to be adapted to be compliant with new evolving paradigms in breast cancer. Copyright © 2014 Elsevier Ltd. All rights reserved.
Multifocal canalicular adenoma of the minor labial salivary glands
Samar, María Elena; Avila, Rodolfo Esteban; Fonseca, Ismael Bernardo; Anderson, William; Fonseca, Gabriel M; Cantín, Mario
2014-01-01
Canalicular adenoma (CA) is an uncommon benign neoplasia of salivary glands which is clinically difficult to recognise. Despite having an excellent prognosis, the histological diagnosis and clinical management of this entity can be troublesome. While the main differential diagnosis to consider is basal cell adenoma (BCA), similar histological patterns and multifocality have been observed in adenoid cystic carcinoma (ACC) and polymorphous low-grade adenocarcinoma (PLGA), both locally-aggressive malignancies which require radically different treatment to CA. An emphasis has been placed on the value of immunohistochemistry in avoiding diagnostic and surgical errors. CA is positive for AE1/AE3, CD117 and S-100 protein, and negative for p63, α-SMA, Ki 67 and vimentin. Here we discuss the case of a 61-year-old female with CA in her right upper lip, showing multifocal growth histologically. The differential diagnosis with other adenomas is discussed in addition to the role of immunohistochemical studies that can confirm the clinical and surgical findings. PMID:25550873
Progressive Multifocal Leukoencephalopathy: Endemic Viruses and Lethal Brain Disease.
Haley, Sheila A; Atwood, Walter J
2017-09-29
In 1971, the first human polyomavirus was isolated from the brain of a patient who died from a rapidly progressing demyelinating disease known as progressive multifocal leukoencephalopathy. The virus was named JC virus after the initials of the patient. In that same year a second human polyomavirus was discovered in the urine of a kidney transplant patient and named BK virus. In the intervening years it became clear that both viruses were widespread in the human population but only rarely caused disease. The past decade has witnessed the discovery of eleven new human polyomaviruses, two of which cause unusual and rare cancers. We present an overview of the history of these viruses and the evolution of JC polyomavirus-induced progressive multifocal leukoencephalopathy over three different epochs. We review what is currently known about JC polyomavirus, what is suspected, and what remains to be done to understand the biology of how this mostly harmless endemic virus gives rise to lethal disease.
Chest Radiological Findings of Patients With Severe H1N1 Pneumonia Requiring Intensive Care.
Rohani, Payam; Jude, Cecilia M; Chan, Kelvin; Barot, Nikhil; Kamangar, Nader
2016-01-01
A new strain of human influenza A (H1N1) virus originated from Mexico in 2009 and spread to more than 190 countries and territories. The World Health Organization (WHO) declared it a level 6 (highest level) pandemic. In August 2010, WHO announced that the H1N1 2009 influenza virus had moved into the postpandemic period. The WHO also declared that this flu strain is expected to continue to circulate as a seasonal virus "for some years to come." The objective of this study is to describe the chest radiographic and computed tomography (CT) findings of patients with severe H1N1 pneumonia admitted to the intensive care unit (ICU) during the 2009 pandemic. Patients with severe H1N1 pneumonia requiring ICU admission have extensive radiographic and CT abnormalities. Eighteen patients, aged 23 to 62 (mean 41), admitted to the ICU at UCLA-Olive View Medical Center with a primary diagnosis of pandemic H1N1 infection, confirmed either via rapid influenza detection test or by real-time reverse transcriptase polymerase chain reaction assay, formed the study population. All patients had chest x-ray (CXR) within 24 hours of admission and 5 patients had CT examinations. In this retrospective study, images were evaluated for the pattern (ground-glass opacities, consolidation, reticular opacities, and nodular opacities), distribution (unilateral/bilateral, upper/middle/lower lung zone, and central/peripheral/peribronchovascular), and extent (focal/multifocal/diffuse; number of lung zones) of abnormalities. All (100%) patients had abnormal CXR and CT studies. The predominant radiographic findings were ground-glass opacities (16 of 18; 89%), consolidation (16 of 18; 89%), and reticular opacities (6 of 18, 33%). The radiographic abnormalities were bilateral in 17 (94%) patients; involved lower lung distribution in 18 (100%) patients, and mid and lower lung distribution in 16 (89%) patients. Radiographic abnormalities were peribronchovascular in 11 (61%) patients and multifocal in 10 (56%). Sixteen (89%) patients had extensive abnormalities involving 3 or more lung zones. The patients requiring mechanical ventilation had a higher incidence of bilateral, diffuse consolidation in a peribronchovascular distribution on chest radiographs. The predominant CT abnormalities were consolidation (5 of 5; 100%), ground-glass opacities (5 of 5; 100%), and nodular opacities (3 of 5, 60%). The CT findings were peribronchovascular and multifocal in 4 (80%) patients and extensive and bilateral in all (100%) patients. Patients with H1N1 pneumonia admitted to the ICU had bilateral, extensive CXR, and CT abnormalities. Consolidations and ground-glass opacities were the most common imaging findings, predominantly affecting mid and lower lung zones. Imaging abnormalities were peribronchovascular and multifocal in a majority of patients. © The Author(s) 2014.
Thoe, Robert S.
1991-01-01
Method and apparatus for producing sharp, chromatic, magnified images of X-ray emitting objects, are provided. The apparatus, which constitutes an X-ray microscope or telescope, comprises a connected collection of Bragg reflecting planes, comprised of either a bent crystal or a synthetic multilayer structure, disposed on and adjacent to a locus determined by a spherical surface. The individual Bragg planes are spatially oriented to Bragg reflect radiation from the object location toward the image location. This is accomplished by making the Bragg planes spatially coincident with the surfaces of either a nested series of prolate ellipsoids of revolution, or a nested series of spheres. The spacing between the Bragg reflecting planes can be tailored to control the wavelengths and the amount of the X-radiation that is Bragg reflected to form the X-ray image.
Space Optical Communications Using Laser Beams
NASA Technical Reports Server (NTRS)
Goorjian, Peter M. (Inventor)
2017-01-01
A system for communicating between an object in space and a ground station, between objects in space, or between ground stations, includes a telecentric lens. Photodetectors positioned upon a focal plane of the telecentric lens detect an inbound light beam, received from a source, that has passed through the telecentric lens to the focal plane. Lasers positioned upon the focal plane transmit light beams from the focal plane through the telecentric lens to an area that includes the source of the inbound light beam. A processor detect signals from individual photodetectors corresponding to light detected, and selectively signals individual lasers that are close to those photodetectors, resulting in a returning beam that arrives close to the source, and which carries encoded data.
[Clinico-pathological features of papillary thyroid cancer coexistent with Hashimoto's thyroiditis].
Molnár, Sarolta; Győry, Ferenc; Nagy, Endre; Méhes, Gábor; Molnár, Csaba
2017-02-01
Former studies suggest the frequent coexistence of Hashimoto's thyreoditis with papillary thyroid cancer, frequently featured by multifocal carcinogenesis but lower clinical stages compared to thyroid cancers lacking thyroiditis. We examined the clinico-pathological correlations between Hashimoto's thyroditis and papillary thyroid cancer in our region in the North-Eastern part of Hungary. We included a total of 230 patients with papillary thyroid cancer who underwent thyroid surgery at the Surgical Department of the University of Debrecen. Patients' sex, age, multifocality of thyroid cancer and clinical stage were evaluated. Cases included 40 patients (17.4%) with (4 male, 36 female) and 190 (82.6%) patients without HT (44 male, 146 female). Hashimoto's thyroiditis related thyroid cancer was almost exclusively associated with the papillary histological type. Multifocality of papillary cancer was significantly more frequent with coexisting Hashimoto's thyroiditis (16/40; 40.0%) compared to cases uninvolved (45/190; 23.7%; p = 0.034). In contrast, lymph node metastasis was significantly less frequent among patients with Hashimoto's thyroiditis (4 pN1 [36.4%]; 7 pN0 [63.6%]) then without it (34 pN1 [82.9%]; 7 pN0 [17.1%]; p = 0.002). Higher frequency and multifocality of papillary thyroid cancer might be the consequence of preexisting Hashimoto's thyroiditis to be considered as a preneoplastic stimulus supporting carcinogenesis, though the exact pathomechanism of this correlation is not clear yet. Orv. Hetil., 2017, 158(5), 178-182.
Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens.
Song, In Seok; Yoon, Sam Young; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon
2016-04-01
To compare visual performance and higher order aberrations (HOAs) based on the position of the near segment in eyes with rotationally asymmetric multifocal intraocular lenses (IOLs). Asymmetric multifocal IOLs (Lentis Mplus LS-313; Oculentis Optikgeräte GmbH, Wetzlar, Germany) were implanted with the near segment positioned either inferiorly, superiorly, or temporally. Uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity, corrected distance visual acuity (CDVA), and distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuity, contrast sensitivity, HOAs, and subjective symptom questionnaires were compared at 1 month postoperatively. Forty-five eyes from 45 patients were evaluated (n = 25, 9, and 11 eyes in the inferior, superior, and temporal groups, respectively). No significant differences in UDVA, UIVA, UNVA, CDVA, DCIVA, or DCNVA were found between the three groups (P > .05). The temporal group showed the best results in UDVA, CDVA, and DCNVA, but the inferior group showed the best results in DCIVA and UNVA and the superior group showed the best results in UIVA. Contrast sensitivity and the subjective symptom questionnaire also did not demonstrate any significant differences (P > .05). Total HOA and spherical aberration did not demonstrate any statistically significant differences (P > .05), but vertical coma and horizontal coma demonstrated significant differences based on near segment position (P < .001). The position of the near segment in eyes with rotationally asymmetric multifocal IOLs demonstrates no significant effect on visual performance. Copyright 2016, SLACK Incorporated.
Maresca, A; Pascarella, R; Bettuzzi, C; Amendola, L; Politano, R; Fantasia, R; Del Torto, M
2014-02-01
Multifocal humeral fractures are extremely rare. These may affect the neck and the shaft, the shaft alone, or the diaphysis and the distal humerus. There is no classification of these fractures in the literature. From 2004 to 2010, 717 patients with humeral fracture were treated surgically at our department. Thirty-five patients presented with an associated fracture of the proximal and diaphyseal humerus: synthesis was performed with plate and screws in 34 patients, and the remaining patient had an open fracture that was treated with an external fixator. Mean follow-up was 3 years and 3 months. A classification is proposed in which type A fractures are those affecting the proximal and the humeral shaft, type B the diaphysis alone, and type C the diaphysis in association with the distal humerus. Type A fractures are then divided into three subgroups: A-I, undisplaced fracture of the proximal humerus and displaced shaft fracture; A-II: displaced fracture of the proximal and humeral shaft; and A-III: multifragmentary fracture affecting the proximal humerus and extending to the diaphysis. Multifocal humeral fractures are very rare and little described in the literature, both for classification and treatment. The AO classification describes bifocal fracture of the humeral diaphysis, type B and C. The classification suggested in this article mainly concerns fractures involving the proximal and humeral shaft. A simple classification of multifocal fractures is suggested to help the surgeon choose the most suitable type of synthesis for surgical treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.
Microincision, aspiration cutter-assisted multifocal iris biopsy for melanoma.
Finger, Paul T; Milman, Tatyana
2017-01-19
To describe a minimally invasive method to create multifocal full-thickness surgical iridectomy biopsies. Seven patients suspected to have diffuse iris melanoma underwent multifocal surgical iridectomy biopsy through a single 1.0-mm clear corneal incision. A 25-G inked trocar was used to create one visible corneal portal, through which the anterior chamber was filled with sodium hyaluronate 1%. Then, a 25-G aspiration cutter probe was introduced through the corneal incision such that the aspiration portal was occluded by the iris biopsy sites. Then aspiration (600 mm Hg) cutting (300 cuts per minute) was used to create full- and partial-thickness surgical iridectomy biopsies at multiple locations. After each biopsy the probe was removed, and its contents aspirated into a separate 3-mL syringe (marked by clock hour location). The sodium hyaluronate 1% was removed and wound checked for leakage. Diagnostic specimens were obtained in all cases. Five were found to be diffuse iris melanomas and 2 were indeterminate iris melanocytic proliferations. No patients developed a secondary increase in intraocular pressure, hyphema, infection, cataract, or vision loss. No cases of intraocular tumor dissemination were observed. No patient complained of glare or monocular diplopia. Three of 7 corneal wounds were self-sealing. Multifocal surgical iridectomy biopsy can be minimally invasive and effective allowing for partial- and full-thickness iris biopsy. Use of a 25-G aspiration cutting probe allowed for small incision surgery, rapid rehabilitation, and no significant complications.
Heterogeneity of DNA methylation in multifocal prostate cancer.
Serenaite, Inga; Daniunaite, Kristina; Jankevicius, Feliksas; Laurinavicius, Arvydas; Petroska, Donatas; Lazutka, Juozas R; Jarmalaite, Sonata
2015-01-01
Most prostate cancer (PCa) cases are multifocal, and separate foci display histological and molecular heterogeneity. DNA hypermethylation is a frequent alteration in PCa, but interfocal heterogeneity of these changes has not been extensively investigated. Ten pairs of foci from multifocal PCa and 15 benign prostatic hyperplasia (BPH) samples were obtained from prostatectomy specimens, resulting altogether in 35 samples. Methylation-specific PCR (MSP) was used to evaluate methylation status of nine tumor suppressor genes (TSGs), and a set of selected TSGs was quantitatively analyzed for methylation intensity by pyrosequencing. Promoter sequences of the RASSF1 and ESR1 genes were methylated in all paired PCa foci, and frequent (≥75 %) DNA methylation was detected in RARB, GSTP1, and ABCB1 genes. MSP revealed different methylation status of at least one gene in separate foci in 8 out of 10 multifocal tumors. The mean methylation level of ESR1, GSTP1, RASSF1, and RARB differed between the paired foci of all PCa cases. The intensity of DNA methylation in these TSGs was significantly higher in PCa cases than in BPH (p < 0.001). Hierarchical cluster analysis revealed a divergent methylation profile of paired PCa foci, while the foci from separate cases with biochemical recurrence showed similar methylation profile and the highest mean levels of DNA methylation. Our findings suggest that PCa tissue is heterogeneous, as between paired foci differences in DNA methylation status were found. Common epigenetic profile of recurrent tumors can be inferred from our data.
NASA Astrophysics Data System (ADS)
Pfister, T.; Günther, P.; Nöthen, M.; Czarske, J.
2010-02-01
Both in production engineering and process control, multidirectional displacements, deformations and vibrations of moving or rotating components have to be measured dynamically, contactlessly and with high precision. Optical sensors would be predestined for this task, but their measurement rate is often fundamentally limited. Furthermore, almost all conventional sensors measure only one measurand, i.e. either out-of-plane or in-plane distance or velocity. To solve this problem, we present a novel phase coded heterodyne laser Doppler distance sensor (PH-LDDS), which is able to determine out-of-plane (axial) position and in-plane (lateral) velocity of rough solid-state objects simultaneously and independently with a single sensor. Due to the applied heterodyne technique, stationary or purely axially moving objects can also be measured. In addition, it is shown theoretically as well as experimentally that this sensor offers concurrently high temporal resolution and high position resolution since its position uncertainty is in principle independent of the lateral object velocity in contrast to conventional distance sensors. This is a unique feature of the PH-LDDS enabling precise and dynamic position and shape measurements also of fast moving objects. With an optimized sensor setup, an average position resolution of 240 nm was obtained.
NASA Astrophysics Data System (ADS)
Kypraios, Ioannis; Young, Rupert C. D.; Chatwin, Chris R.; Birch, Phil M.
2009-04-01
θThe window unit in the design of the complex logarithmic r-θ mapping for hybrid optical neural network filter can allow multiple objects of the same class to be detected within the input image. Additionally, the architecture of the neural network unit of the complex logarithmic r-θ mapping for hybrid optical neural network filter becomes attractive for accommodating the recognition of multiple objects of different classes within the input image by modifying the output layer of the unit. We test the overall filter for multiple objects of the same and of different classes' recognition within cluttered input images and video sequences of cluttered scenes. Logarithmic r-θ mapping for hybrid optical neural network filter is shown to exhibit with a single pass over the input data simultaneously in-plane rotation, out-of-plane rotation, scale, log r-θ map translation and shift invariance, and good clutter tolerance by recognizing correctly the different objects within the cluttered scenes. We record in our results additional extracted information from the cluttered scenes about the objects' relative position, scale and in-plane rotation.
Designing multifocal corneal models to correct presbyopia by laser ablation
NASA Astrophysics Data System (ADS)
Alarcón, Aixa; Anera, Rosario G.; Del Barco, Luis Jiménez; Jiménez, José R.
2012-01-01
Two multifocal corneal models and an aspheric model designed to correct presbyopia by corneal photoablation were evaluated. The design of each model was optimized to achieve the best visual quality possible for both near and distance vision. In addition, we evaluated the effect of myosis and pupil decentration on visual quality. The corrected model with the central zone for near vision provides better results since it requires less ablated corneal surface area, permits higher addition values, presents stabler visual quality with pupil-size variations and lower high-order aberrations.
Multifocal Tubercular Dactylitis: A Rare Presentation of Skeletal Tuberculosis in an Adult.
Thatoi, Pravat; Parida, Manoj; Barik, Rakesh; Das, Bidyut
2017-06-01
Tubercular dactylitis is an uncommon form of osteo-articular tuberculosis seen in children. Multifocal involvement, simultaneously involving hands and feet is extremely uncommon. Here we report an adult patient with tubercular dactylitis involving multiple digits of both hands and second digit of right foot in absence of any risk factors like immunodeficiency or any debilitating condition. The patient was successfully treated with anti-tubercular drugs for six months. Mycobacterium tuberculosis infection of bones and joints can present in an unusual way but early diagnosis and treatment caries a good prognosis.
Gómez Rodríguez, N; Durán Muñoz, O
2006-12-01
In absence of risk factors, osteoarticular infections by coagulase-negative staphylococci are very infrequent. We described the case of a immunocompetent 73-year-old-woman that suffered pyomyositis, left sacroiliitis and spondylodiscitis involving the first and second thoracic vertebrae by Staphylococcus hominis. This multifocal infection occurred five-weeks after intramuscular administration of NSAI for treatment of low back pain associated with a herniated disc L4-L5. This is the first know case of a multifocal muscle skeletal infection by Staphylococcus hominis in a patient immunocompetent.
Strategy in Regulatory Decision-Making for Management of Progressive Multifocal Leukoencephalopathy.
Segec, A; Keller-Stanislawski, B; Vermeer, N S; Macchiarulo, C; Straus, S M; Hidalgo-Simon, A; De Bruin, M L
2015-11-01
Progressive multifocal leukoencephalopathy (PML) has been observed after the use of several medicines, including monoclonal antibodies. As these drugs play important roles in the therapeutic armamentarium, it is important to address the challenges that this severe adverse reaction poses to the safe use of medicines. Considering the need for consistent outcomes of regulatory decisions, the European Medicines Agency Pharmacovigilance Risk Assessment Committee (PRAC) used PML as an example to develop a systematic approach to labeling and risk minimization. © 2015 American Society for Clinical Pharmacology and Therapeutics.
Influence of strike object grounding on close lightning electric fields
NASA Astrophysics Data System (ADS)
Baba, Yoshihiro; Rakov, Vladimir A.
2008-06-01
Using the finite difference time domain (FDTD) method, we have calculated vertical electric field Ez, horizontal (radial) electric field Eh, and azimuthal magnetic field Hϕ produced on the ground surface by lightning strikes to 160-m- and a 553-m-high conical strike objects representing the Peissenberg tower (Germany) and the CN Tower (Canada), respectively. The fields were computed for a typical subsequent stroke at distances d' from the bottom of the object ranging from 5 to 100 m for the 160-m tower and from 10 to 300 m for the 553-m tower. Grounding of the 160-m object was assumed to be accomplished by its underground basement represented by a 10-m-radius and 8-m-long perfectly conducting cylinder with or without a reference ground plane located 2 m below. The reference ground plane simulates, to some extent, a higher-conducting ground layer that is expected to exist below the water table. The configuration without reference ground plane actually means that this plane is present, but is located at an infinitely large depth. Grounding of the 553-m object was modeled in a similar manner but in the absence of reference ground plane only. In all cases considered, waveforms of Eh and Hϕ are not much influenced by the presence of strike object, while waveforms of Ez are. Waveforms of Ez are essentially unipolar (as they are in the absence of strike object) when the ground conductivity σ is 10 mS/m (the equivalent transient grounding impedance is several ohms) or greater. Thus, for the CN Tower, for which σ ≥ 10 mS/m, the occurrence of Ez polarity change is highly unlikely. For the 160-m tower and for σ = 1 and 0.1 mS/m, waveforms of Ez become bipolar (exhibit polarity change) at d' ≤ 10 m and d' ≤ 50 m, respectively, regardless of the presence of the reference ground plane. The corresponding equivalent transient grounding impedances are about 30 and 50 Ω in the absence of the reference ground plane and smaller than 10 Ω in the presence of the reference ground plane. The source of opposite polarity Ez is the potential rise at the object base (at the air/ground interface) relative to the reference ground plane. For a given grounding electrode geometry, the strength of this source increases with decreasing σ, provided that the grounding impedance is linear. Potential rises at the strike object base for σ = 1 and 0.1 mS/m are some hundreds of kilovolts, which is sufficient to produce electrical breakdown from relatively sharp edges of the basement over a distance of several meters (or more) along the ground surface. The resultant ground surface arcs will serve to reduce the equivalent grounding impedance and, hence, potential rise. Therefore, the polarity change of Ez near the Peissenberg tower, for which σ is probably about 1 mS/m, should be a rare phenomenon, if it occurs at all. The equivalent transient grounding impedance of the cylindrical basement is similar to that of a hemispherical grounding electrode of the same radius. For the 160-m tower and for hemispherical grounding electrode, the transient grounding impedance is higher than its dc grounding resistance for σ = 10 and 1 mS/m, but lower for σ = 0.1 mS/m. For the 553-m tower, the transient grounding impedance of hemispherical electrode is equal to or larger than its dc resistance for all values of σ considered.
Plane Transformations in a Complex Setting III: Similarities
ERIC Educational Resources Information Center
Dana-Picard, Thierry
2009-01-01
This is the third part of a study of plane transformations described in a complex setting. After the study of homotheties, translations, rotations and reflections, we proceed now to the study of plane similarities, either direct or inverse. Their group theoretical properties are described, and their action on classical geometrical objects is…
Identification of occult tumors by whole-specimen mapping in solitary papillary thyroid carcinoma.
Park, Seog Yun; Jung, Yuh-S; Ryu, Chang Hwan; Lee, Chang Yoon; Lee, You Jin; Lee, Eun Kyung; Kim, Seok-Ki; Kim, Tae Sung; Kim, Tae Hyun; Jang, Jeyun; Park, Daeyoon; Dong, Seung Myung; Kang, Jae-Goo; Lee, Jin Soo; Ryu, Junsun
2015-08-01
We undertook this study to estimate an accurate incidence and spread patterns of occult papillary thyroid carcinoma (PTC) in patients with a preoperative diagnosis of solitary PTC by using whole-specimen mapping of all specimens after a total thyroidectomy. Enrolled prospectively in this whole-thyroid mapping study are 82 consecutive patients who underwent a total thyroidectomy under a preoperative diagnosis of solitary PTC. All thyroidectomy specimens were serially sectioned in 2 mm thickness and whole-thyroid mapping was carried out for additional foci of occult PTC. The frequencies of occult lesions detected in the whole and contralateral lobe were determined, and clinicopathologic factors associated with multifocality were assessed. Whole-thyroid mapping revealed 66 occult PTC lesions missed by preoperative ultrasound in 37 (45.1%) of the 82 patients. The great majority (92.5%) of the occult PTC was smaller than 3 mm in size and 25 patients (30.5%) had contralateral lesions. We found that the male sex was an independent predictor of multifocality (odds ratio (OR), 3.00; 95% CI, 1.11-8.14), adjusting for preoperative findings. Analysis with pathologic parameters showed that the male sex (OR, 5.03; 95% CI, 1.68-15.08) and extrathyroidal extensions (OR, 3.03; 95% CI, 1.03-8.95) were associated with multifocal PTC. However, none of the clinicopathologic factors evaluated predicted contralateral PTC. Our study demonstrates the diagnostic limitations of ultrasound for the detection of multifocal PTC and the need to consider the possibility of occult lesions in the management of solitary PTC, especially in male patients. © 2015 Society for Endocrinology.
Rosen, Emanuel; Alió, Jorge L; Dick, H Burkhard; Dell, Steven; Slade, Stephen
2016-02-01
We performed a metaanaysis of peer-reviewed studies involving implantation of a multifocal intraocular lens (IOL) in presbyopic patients with cataract or having refractive lens exchange (RLE). Previous reviews have considered the use of multifocal IOLs after cataract surgery but not after RLE, whereas greater insight might be gained from examining the full range of studies. Selected studies were examined to collate outcomes with monocular and binocular uncorrected distance, intermediate, and near visual acuity; spectacle independence; contrast sensitivity; visual symptoms; adverse events; and patient satisfaction. In 8797 eyes, the mean postoperative monocular uncorrected distance visual acuity (UDVA) was 0.05 logMAR ± 0.006 (SD) (Snellen equivalent 20/20(-3)). In 6334 patients, the mean binocular UDVA was 0.04 ± 0.00 logMAR (Snellen equivalent 20/20(-2)), with a mean spectacle independence of 80.1%. Monocular mean UDVA did not differ significantly between those who had a cataract procedure and those who had an RLE procedure. Neural adaptation to multifocality may vary among patients. Dr. Alió is a clinical research investigator for Hanita Lenses, Carl Zeiss Meditec AG, Topcon Medical Systems, Inc., Oculentis GmbH, and Akkolens International BV. Dr. Dell is a consultant to Bausch & Lomb and Abbott Medical Optics, Inc. Dr. Slade is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, and Bausch & Lomb. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Exploring the optimum step size for defocus curves.
Wolffsohn, James S; Jinabhai, Amit N; Kingsnorth, Alec; Sheppard, Amy L; Naroo, Shehzad A; Shah, Sunil; Buckhurst, Phillip; Hall, Lee A; Young, Graeme
2013-06-01
To evaluate the effect of reducing the number of visual acuity measurements made in a defocus curve on the quality of data quantified. Midland Eye, Solihull, United Kingdom. Evaluation of a technique. Defocus curves were constructed by measuring visual acuity on a distance logMAR letter chart, randomizing the test letters between lens presentations. The lens powers evaluated ranged between +1.50 diopters (D) and -5.00 D in 0.50 D steps, which were also presented in a randomized order. Defocus curves were measured binocularly with the Tecnis diffractive, Rezoom refractive, Lentis rotationally asymmetric segmented (+3.00 D addition [add]), and Finevision trifocal multifocal intraocular lenses (IOLs) implanted bilaterally, and also for the diffractive IOL and refractive or rotationally asymmetric segmented (+3.00 D and +1.50 D adds) multifocal IOLs implanted contralaterally. Relative and absolute range of clear-focus metrics and area metrics were calculated for curves fitted using 0.50 D, 1.00 D, and 1.50 D steps and a near add-specific profile (ie, distance, half the near add, and the full near-add powers). A significant difference in simulated results was found in at least 1 of the relative or absolute range of clear-focus or area metrics for each of the multifocal designs examined when the defocus-curve step size was increased (P<.05). Faster methods of capturing defocus curves from multifocal IOL designs appear to distort the metric results and are therefore not valid. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Bansagi, Boglarka; Phan, Vietxuan; Baker, Mark R; O'Sullivan, Julia; Jennings, Matthew J; Whittaker, Roger G; Müller, Juliane S; Duff, Jennifer; Griffin, Helen; Miller, James A L; Gorman, Grainne S; Lochmüller, Hanns; Chinnery, Patrick F; Roos, Andreas; Swan, Laura E; Horvath, Rita
2018-05-22
To describe a patient with a multifocal demyelinating motor neuropathy with onset in childhood and a mutation in phosphatase and tensin homolog ( PTEN ), a tumor suppressor gene associated with inherited tumor susceptibility conditions, macrocephaly, autism, ataxia, tremor, and epilepsy. Functional implications of this protein have been investigated in Parkinson and Alzheimer diseases. We performed whole-exome sequencing in the patient's genomic DNA validated by Sanger sequencing. Immunoblotting, in vitro enzymatic assay, and label-free shotgun proteomic profiling were performed in the patient's fibroblasts. The predominant clinical presentation of the patient was a childhood onset, asymmetric progressive multifocal motor neuropathy. In addition, he presented with macrocephaly, autism spectrum disorder, and skin hamartomas, considered as clinical criteria for PTEN-related hamartoma tumor syndrome. Extensive tumor screening did not detect any malignancies. We detected a novel de novo heterozygous c.269T>C, p.(Phe90Ser) PTEN variant, which was absent in both parents. The pathogenicity of the variant is supported by altered expression of several PTEN-associated proteins involved in tumorigenesis. Moreover, fibroblasts showed a defect in catalytic activity of PTEN against the secondary substrate, phosphatidylinositol 3,4-trisphosphate. In support of our findings, focal hypermyelination leading to peripheral neuropathy has been reported in PTEN-deficient mice. We describe a novel phenotype, PTEN-associated multifocal demyelinating motor neuropathy with a skin hamartoma syndrome. A similar mechanism may potentially underlie other forms of Charcot-Marie-Tooth disease with involvement of the phosphatidylinositol pathway. Copyright © 2018 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.
Nordström, Britta; Einhorn, N; Silfverswärd, C; Sjövall, K; Tryggvason, K; Auer, G
2002-01-01
During recent decades it has become apparent that there are two types of vulvar disease: the classic type found in elderly women with unicentric and unifocal lesions, and the type found in younger women, in which precancerous and invasive changes develop in the anogenital lower tract in a multicentric and multifocal fashion, often over a long period of observation. The laminin-5 gamma 2 chain is an extracellular protein that is a component of the basement membrane. Recently its expression has been recognized as a marker in cervical cancer that permits identification of invasive capacity. The aim of our study was to determine if laminin-5 gamma 2 chain antibody can act as a sensitivity marker of invasive capacity in precancerous and invasive carcinoma in women with uni- and multifocal changes in the anogenital tract. The result showed that all patients in the older group of women with invasive carcinoma of the vulva had moderate to high positive expression of the laminin-5 gamma 2 chain. In the group of younger patients with multifocal precancerous changes observed over long periods, most of the patients with vulva intraepithelial neoplasia (VIN) 3 showed laminin-5 gamma 2 chain positivity already in the precancerous changes, and all of them developed invasivity during the period of observation. Normal epithelium without atypia was mostly negative or of low immunoreactivity of laminin-5. In conclusion, positive laminin-5 gamma 2 chain expression seems to indicate the invasiveness potential of precancerous lesions and is also expressed in all investigated invasive carcinomas of the anogenital tract.
Blanco Saiz, I; López Carballo, M T; Martínez Fernández, J; Carrión Maldonado, J; Cabrera Pereira, A; Moral Alvarez, S; Santamaría Girón, L; Cantero Cerquella, F; López Secades, A; Díaz González, D; Llaneza Folgueras, A; Aira Delgado, F J
2014-01-01
Sentinel lymph node biopsy (SLNB) as a staging procedure in multiple breast cancer is a controversial issue. We have aimed to evaluate the efficacy of sentinel node (SN) detection in patients with multifocal or multicentric breast cancer as well as the safety of its clinical application after a long follow-up. A prospective descriptive study was performed. Eighty-nine patients diagnosed of multiple breast cancer (73 multifocal; 16 multicentric) underwent SLNB. These patients were compared to those with unifocal neoplasia. Periareolar radiocolloid administration was performed in most of the patients. Evaluation was made at an average of 67.2 months of follow-up (32-126 months). Scintigraphic and surgical SN localization in patients with multiple breast cancer were 95.5% and 92.1%, respectively. A higher percentage of extra-axillary nodes was observed than in the unifocal group (11.7% vs 5.4%) as well as a significantly higher number of SN per patient (1.70 vs 1.38). The rate of SN localization in multicentric cancer was slightly lower than in multifocal cancer (87.5% vs 93.1%), and the finding of extra-axillary drainages was higher (20% vs 10%). Number of SN per patient was significantly higher in multicentric breast cancer (2.33 vs 1.57). No axillary relapses have been demonstrated in the follow-up in multiple breast cancer patients group. SLNB performed by periareolar injection is a reliable and accurate staging procedure of patients with multiple breast cancer, including those with multicentric processes. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
The DECam Plane Survey: Optical photometry of two billion objects in the southern Galactic plane
NASA Astrophysics Data System (ADS)
Schlafly, Edward; Green, Gregory M.; Lang, Dustin; Daylan, Tansu; Finkbeiner, Douglas; Lee, Albert; Meisner, Aaron; Schlegel, David; Valdes, Francisco
2018-01-01
The DECam Plane Survey is a five-band optical and near-infrared survey of the southern Galactic plane with the Dark Energy Camera at Cerro Tololo. The survey is designed to reach past the main-sequence turn-off at the distance of the Galactic center through a reddening E(B-V) of 1.5 mag. Typical single-exposure depths are 23.7, 22.8, 22.3, 21.9, and 21.0 mag in the grizY bands, with seeing around 1 arcsecond. The footprint covers the Galactic plane with |b| < 4°, 5° > l > -120°. The survey pipeline simultaneously solves for the positions and fluxes of tens of thousands of sources in each image, delivering positions and fluxes of roughly two billion stars with better than 10 mmag precision. Most of these objects are highly reddened and deep in the Galactic disk, probing the structure and properties of the Milky Way and its interstellar medium. The full survey is publicly available.
Nakanishi, Masaki; Wang, Yu-Te; Jung, Tzyy-Ping; Zao, John K; Chien, Yu-Yi; Diniz-Filho, Alberto; Daga, Fabio B; Lin, Yuan-Pin; Wang, Yijun; Medeiros, Felipe A
2017-06-01
The current assessment of visual field loss in diseases such as glaucoma is affected by the subjectivity of patient responses and the lack of portability of standard perimeters. To describe the development and initial validation of a portable brain-computer interface (BCI) for objectively assessing visual function loss. This case-control study involved 62 eyes of 33 patients with glaucoma and 30 eyes of 17 healthy participants. Glaucoma was diagnosed based on a masked grading of optic disc stereophotographs. All participants underwent testing with a BCI device and standard automated perimetry (SAP) within 3 months. The BCI device integrates wearable, wireless, dry electroencephalogram and electrooculogram systems and a cellphone-based head-mounted display to enable the detection of multifocal steady state visual-evoked potentials associated with visual field stimulation. The performances of global and sectoral multifocal steady state visual-evoked potentials metrics to discriminate glaucomatous from healthy eyes were compared with global and sectoral SAP parameters. The repeatability of the BCI device measurements was assessed by collecting results of repeated testing in 20 eyes of 10 participants with glaucoma for 3 sessions of measurements separated by weekly intervals. Receiver operating characteristic curves summarizing diagnostic accuracy. Intraclass correlation coefficients and coefficients of variation for assessing repeatability. Among the 33 participants with glaucoma, 19 (58%) were white, 12 (36%) were black, and 2 (6%) were Asian, while among the 17 participants with healthy eyes, 9 (53%) were white, 8 (47%) were black, and none were Asian. The receiver operating characteristic curve area for the global BCI multifocal steady state visual-evoked potentials parameter was 0.92 (95% CI, 0.86-0.96), which was larger than for SAP mean deviation (area under the curve, 0.81; 95% CI, 0.72-0.90), SAP mean sensitivity (area under the curve, 0.80; 95% CI, 0.69-0.88; P = .03), and SAP pattern standard deviation (area under the curve, 0.77; 95% CI, 0.66-0.87; P = .01). No statistically significant differences were seen for the sectoral measurements between the BCI and SAP. Intraclass coefficients for global and sectoral parameters ranged from 0.74 to 0.92, and mean coefficients of variation ranged from 3.03% to 7.45%. The BCI device may be useful for assessing the electrical brain responses associated with visual field stimulation. The device discriminated eyes with glaucomatous neuropathy from healthy eyes in a clinically based setting. Further studies should investigate the feasibility of the BCI device for home-based testing as well as for detecting visual function loss over time.
Laron, Michal; Cheng, Han; Zhang, Bin; Schiffman, Jade S.; Tang, Rosa A.; Frishman, Laura J.
2010-01-01
Background Multifocal visual evoked potentials (mfVEP) measure local response amplitude and latency in the field of vision Objective To compare the sensitivity of mfVEP, Humphrey visual field (HVF) and optical coherence tomography (OCT) in detecting visual abnormality in multiple sclerosis (MS) patients. Methods MfVEP, HVF, and OCT (retinal nerve fiber layer [RNFL]) were performed in 47 MS-ON eyes (last optic neuritis (ON) attack ≥ 6 months prior) and 65 MS-no-ON eyes without ON history. Criteria to define an eye as abnormal were: mfVEP 1) amplitude/latency: either amplitude or latency probability plots meeting cluster criteria with 95% specificity 2) amplitude or latency alone (specificity: 97% and 98%, respectively); HVF and OCT, mean deviation and RNFL thickness meeting p < 0.05, respectively. Results MfVEP (amplitude/latency) identified more abnormality in MS-ON eyes (89%) than HVF (72%), OCT (62%), mfVEP amplitude (66%) or latency (67%) alone. 18% of MS-no-ON eyes were abnormal for both mfVEP (amplitude/latency) and HVF compared to 8% with OCT. Agreement between tests ranged from 60% to 79%. MfVEP (amplitude/latency) categorized an additional 15% of MS-ON eyes as abnormal compared to HVF and OCT combined. Conclusions MfVEP, which detects both demyelination (increased latency) and neural degeneration (reduced amplitude) revealed more abnormality than HVF or OCT in MS patients. PMID:20207786
Blanco, Román; Pérez-Rico, Consuelo; Puertas-Muñoz, Inmaculada; Ayuso-Peralta, Lucía; Boquete, Luciano; Arévalo-Serrano, Juan
2014-02-01
To objectively evaluate the visual function, and the relationship between disability and optic nerve dysfunction, in patients with multiple sclerosis (MS) and optic neuritis (ON), using multifocal visual evoked potentials (mfVEP). This observational, cross-sectional study assessed 28 consecutive patients with clinically definite MS, according to the McDonald criteria, and 19 age-matched healthy subjects. Disability was recorded using the Expanded Disability Status Scale (EDSS) score. The patients' mfVEP were compared to their clinical, psychophysical (Humphrey perimetry) and structural (optic coherence tomography (OCT)) diagnostic test data. We observed a significant agreement between mfVEP amplitude and Humphrey perimetry/OCT in MS-ON eyes, and between mfVEP amplitude and OCT in MS but non-ON eyes. We found significant differences in EDSS score between patients with abnormal and normal mfVEP amplitudes. Abnormal mfVEP amplitude defects (from interocular and monocular probability analysis) were found in 67.9% and 73.7% of the MS-ON and MS-non-ON group eyes, respectively. Delayed mfVEP latencies (interocular and monocular probability analysis) were seen in 70.3% and 73.7% of the MS-ON and MS-non-ON groups, respectively. We found a significant relationship between mfVEP amplitude and disease severity, as measured by EDSS score, that suggested there is a role for mfVEP amplitude as a functional biomarker of axonal loss in MS.
Ground-plane influences on size estimation in early visual processing.
Champion, Rebecca A; Warren, Paul A
2010-07-21
Ground-planes have an important influence on the perception of 3D space (Gibson, 1950) and it has been shown that the assumption that a ground-plane is present in the scene plays a role in the perception of object distance (Bruno & Cutting, 1988). Here, we investigate whether this influence is exerted at an early stage of processing, to affect the rapid estimation of 3D size. Participants performed a visual search task in which they searched for a target object that was larger or smaller than distracter objects. Objects were presented against a background that contained either a frontoparallel or slanted 3D surface, defined by texture gradient cues. We measured the effect on search performance of target location within the scene (near vs. far) and how this was influenced by scene orientation (which, e.g., might be consistent with a ground or ceiling plane, etc.). In addition, we investigated how scene orientation interacted with texture gradient information (indicating surface slant), to determine how these separate cues to scene layout were combined. We found that the difference in target detection performance between targets at the front and rear of the simulated scene was maximal when the scene was consistent with a ground-plane - consistent with the use of an elevation cue to object distance. In addition, we found a significant increase in the size of this effect when texture gradient information (indicating surface slant) was present, but no interaction between texture gradient and scene orientation information. We conclude that scene orientation plays an important role in the estimation of 3D size at an early stage of processing, and suggest that elevation information is linearly combined with texture gradient information for the rapid estimation of 3D size. Copyright 2010 Elsevier Ltd. All rights reserved.
Tactile recognition and localization using object models: the case of polyhedra on a plane.
Gaston, P C; Lozano-Perez, T
1984-03-01
This paper discusses how data from multiple tactile sensors may be used to identify and locate one object, from among a set of known objects. We use only local information from sensors: 1) the position of contact points and 2) ranges of surface normals at the contact points. The recognition and localization process is structured as the development and pruning of a tree of consistent hypotheses about pairings between contact points and object surfaces. In this paper, we deal with polyhedral objects constrained to lie on a known plane, i.e., having three degrees of positioning freedom relative to the sensors. We illustrate the performance of the algorithm by simulation.
Multifocal bilateral metatarsal tuberculosis: a rare presentation.
Vijay, Vipul; Sud, Alok; Mehtani, Anil
2015-01-01
Tuberculosis, or phthisis (consumption) as it was popularly known in the Greek era, has been endemic in Southeast Asia and Sub-Saharan Africa; however, the human immunodeficiency virus epidemic has seen the re-emergence of this disease in the areas in which it was not very commonly reported. With this, the need for understanding and treatment of rare presentations of tuberculosis has become of paramount importance to achieve the World Health Organization millennium goal of a "reversal of incidence by 2015." Foot involvement has been reported in 0.1% to 0.3% of extrapulmonary cases. Multifocal lesions have an incidence of <10% in osteoarticular tuberculosis. Bilateral feet involvement in multifocal tuberculosis has not yet been reported in either children or adults in published studies. We report a case of tuberculosis with lesions in the bilateral metatarsals, the occurrence of which is very rare. The diagnosis was mainly histopathologic owing to the paucibacillary nature of the disease. Early identification and treatment with antitubercular drugs will normally result in a good cosmetic and functional result. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Lee, Ching-Yu; Li, Yen-Yao; Huang, Tsan-Wen; Huang, Tsung-Yu; Hsu, Wei-Hsiu; Tsai, Yao-Hung; Huang, Jou-Chen; Huang, Kuo-Chin
2016-12-01
No reports have been published on synchronous multifocal necrotizing fasciitis (SMNF), a multifocal presence of necrotizing fasciitis in different extremities. We evaluated the clinical characteristics and outcomes of SMNF. Eighteen patients (14 men, 4 women; mean age: 59 years) diagnosed with SMNF of the extremities between January 2004 to December 2012 were enrolled and evaluated. Vibrio species were the most commonly (78%; n = 14) isolated; others were two cases (11%) of Aeromonas spp., one case (6%) of group A β-hemolytic streptococcus, and one case of coagulase-negative staphylococcus. SMNF was in the bilateral lower limbs (72%; n = 13), bilateral upper limbs (17%; n = 3), and one patient with one upper and one lower limb (11%). Non-surviving patients had more bilateral lower limb involvement and thrombocytopenia. Most patients with SMNF were male and had bilateral lower limb and marine Gram-negative bacteria involvement. The mortality of SMNF remained extremely high in patients with involvement of bilateral lower limb and initial thrombocytopenia.
Higley, Meghan; Beckett, Brooke; Schmahmann, Sandra; Dacey, Elizabeth; Foss, Erik
2015-12-01
Tumor-induced osteomalacia (TIO) has long been recognized as a clinical paraneoplastic syndrome. The identification of a unique histopathologic entity, the phosphaturic mesenchymal tumor (PMT), as a distinct etiology for TIO has been a more recent discovery. The majority of published cases describe a solitary, non-aggressive appearing soft tissue or osseous lesions in patients with osteomalacia; aggressive appearing or multifocal lesions appear to be exceedingly rare. These tumors characteristically secrete fibroblast growth factor 23 (FGF23). Elevated serum levels of FGF23 result in phosphate wasting and osteomalacia. In the majority of cases, laboratory abnormalities and clinical signs and symptoms of osteomalacia precede identification of the causative lesion by years. Following diagnosis, complete resection with wide margins to prevent local recurrence is most often curative. Imaging characteristics of PMT are diverse and remain incompletely defined, as the majority of previous publications are outside of the radiologic literature. We present multiple imaging modalities in two cases of patients with debilitating osteomalacia and unusual appearing PMTs: one with a locally aggressive lesion leading to pathologic fracture, the second presenting with exceedingly rare multifocal PMT.
Multifocal ERG findings in carriers of X-linked retinoschisis
Kim, Linda S.; Seiple, William; Szlyk, Janet P.
2006-01-01
Purpose To determine whether retinal dysfunction in obligate carriers of X-linked retinoschisis (XLRS) could be observed in local electroretinographic responses obtained with the multifocal electroretinogram (mfERG). Methods Nine obligate carriers of XLRS (mean age, 46.2 years) were examined for the study. Examination of each carrier included an ocular examination and mfERG testing. For the mfERG, we used a 103-scaled hexagonal stimulus array that subtended a retinal area of approximately 40° in diameter. The amplitudes and implicit times in each location for the mfERG were compared with the corresponding values determined for a group of 34 normally-sighted, age-similar control subjects. Results Mapping of 103 local electroretinographic response amplitudes and implicit times within a central 40° area with the mfERG showed regions of reduced mfERG amplitudes and delayed implicit times in two of nine carriers. Conclusions The mfERG demonstrated areas of retinal dysfunction in two carriers of XLRS. When present, retinal dysfunction was evident in the presence of a normal-appearing fundus. Multifocal ERG testing can be useful for identifying some carriers of XLRS. PMID:17180613
Ma, Qian; Khademhosseinieh, Bahar; Huang, Eric; Qian, Haoliang; Bakowski, Malina A; Troemel, Emily R; Liu, Zhaowei
2016-08-16
The conventional optical microscope is an inherently two-dimensional (2D) imaging tool. The objective lens, eyepiece and image sensor are all designed to capture light emitted from a 2D 'object plane'. Existing technologies, such as confocal or light sheet fluorescence microscopy have to utilize mechanical scanning, a time-multiplexing process, to capture a 3D image. In this paper, we present a 3D optical microscopy method based upon simultaneously illuminating and detecting multiple focal planes. This is implemented by adding two diffractive optical elements to modify the illumination and detection optics. We demonstrate that the image quality of this technique is comparable to conventional light sheet fluorescent microscopy with the advantage of the simultaneous imaging of multiple axial planes and reduced number of scans required to image the whole sample volume.
NASA Astrophysics Data System (ADS)
Weber, V. L.
2018-03-01
We statistically analyze the images of the objects of the "light-line" and "half-plane" types which are observed through a randomly irregular air-water interface. The expressions for the correlation function of fluctuations of the image of an object given in the form of a luminous half-plane are found. The possibility of determining the spatial and temporal correlation functions of the slopes of a rough water surface from these relationships is shown. The problem of the probability of intersection of a small arbitrarily oriented line segment by the contour image of a luminous straight line is solved. Using the results of solving this problem, we show the possibility of determining the values of the curvature variances of a rough water surface. A practical method for obtaining an image of a rectilinear luminous object in the light rays reflected from the rough surface is proposed. It is theoretically shown that such an object can be synthesized by temporal accumulation of the image of a point source of light rapidly moving in the horizontal plane with respect to the water surface.
Pohit, M; Sharma, J
2015-05-10
Image recognition in the presence of both rotation and translation is a longstanding problem in correlation pattern recognition. Use of log polar transform gives a solution to this problem, but at a cost of losing the vital phase information from the image. The main objective of this paper is to develop an algorithm based on Fourier slice theorem for measuring the simultaneous rotation and translation of an object in a 2D plane. The algorithm is applicable for any arbitrary object shift for full 180° rotation.
Manipulating Digital Holograms to Modify Phase of Reconstructed Wavefronts
NASA Astrophysics Data System (ADS)
Ferraro, Pietro; Paturzo, Melania; Memmolo, Pasquale; Finizio, Andrea
2010-04-01
We show that through an adaptive deformation of digital holograms it is possible to manage the depth of focus in the numerical reconstruction. Deformation is applied to the original hologram with the aim to put simultaneously in-focus, and in one reconstructed image plane, different objects lying at different distance from the hologram plane (i.e. CCD sensor), but in the same field of view. In the same way it is possible to extend the depth of field for 3D object having a tilted object whole in-focus.
2009-06-30
VIStology, Inc. June 30, 2009 Page 16 Figure 3. Situations and Perception Figure 3 shows four planes, each referring to a different level...the computer, as shown in the figure. The next layer is denoted as “ Perception .” The dots on this plane represent objects from the World that are...which then feeds the computer, which in turn generates the object representations. The label “ Perception ” represents the fact that this kind of
van der Pol, R; Nieuwenhuis, M G; Mourits, M P
1999-03-01
Multifocal fibrosclerosis (MF) is a rare disease that may be misdiagnosed as Graves' orbitopathy. The combination of localisations of MF presented here has not been reported before. A 44-year-old man was referred with progressive bilateral exophthalmos. CT of his chest and abdomen revealed an intrathoracic and retroperitoneal peri-aortal soft-tissue process with hydronephrosis. Histological examination of orbital masses showed a fibrous process with low inflammatory activity. Later the sella was found to be involved as well. A diagnosis of MF was made. MF should be considered in the differential diagnosis of bilateral exophthalmos.
Molloy, Eamonn S; Calabrese, Cassandra M; Calabrese, Leonard H
2017-02-01
Progressive multifocal leukoencephalopathy (PML) is a rare, typically fatal, demyelinating central nervous system infection caused by reactivation of the John Cunningham virus that generally occurs in immunosuppressed patients. With an evolving understanding of a greater clinical heterogeneity of PML and significant implications for therapy, PML should be considered in the differential diagnosis of neurologic presentations of rheumatic diseases. Increased awareness of PML among rheumatologists is required, as earlier diagnosis and restoration of immune function may improve the otherwise grim prognosis associated with PML. Copyright © 2016 Elsevier Inc. All rights reserved.
George, Monica C; Lazer, Zane P; George, David S
2016-05-01
We present a technique that uses a near-point string to demonstrate the anticipated near point of multifocal and accommodating intraocular lenses (IOLs). Beads are placed on the string at distances corresponding to the near points for diffractive and accommodating IOLs. The string is held up to the patient's eye to demonstrate where each of the IOLs is likely to provide the best near vision. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
[Design and optical principles of multifocal lenses].
Auffarth, G U; Rabsilber, T M; Kohnen, T; Holzer, M P
2008-06-01
Multifocal intraocular lenses (MIOLs) of different designs have been used for more than 20 years in modern cataract surgery. The first IOLs were either refractive 2-3-zone designs or of diffractive concept. All MIOL types, regardless of manufacturer, show reduced contrast sensitivity and increased glare for years. Nevertheless, even first-generation MIOL patients had very good functional results when patient selection, IOL calculation, and surgical techniques were appropriate. Today's gold standard is foldable, aspherical diffractive, or refractive MIOLS. Advancements in technology allow the possibility that MIOLs will be used for aphakia correction as well as presbyopia correction.
Optimizing outcomes with multifocal intraocular lenses
Sachdev, Gitansha Shreyas; Sachdev, Mahipal
2017-01-01
Modern day cataract surgery is evolving from a visual restorative to a refractive procedure. The advent of multifocal intraocular lenses (MFIOLs) allows greater spectacle independence and increased quality of life postoperatively. Since the inception in 1980s, MFIOLs have undergone various technical advancements including trifocal and extended depth of vision implants more recently. A thorough preoperative workup including the patients’ visual needs and inherent ocular anatomy allows us to achieve superior outcomes. This review offers a comprehensive overview of the various types of MFIOLs and principles of optimizing outcomes through a comprehensive preoperative screening and management of postoperative complications. PMID:29208809
The clinical presentation and surgical treatment of verrucous dermatitis lesions in a draught horse.
Poore, Luke A B; Else, Rod W; Licka, Theresia L
2012-02-01
Verrucous pastern dermatitis is a progressive inflammatory skin disease commonly involving the palmar or plantar aspects of the pasterns of horses. There are no reports of successful surgical treatment for multifocal circumscribed verrucous masses in the chronic stages of verrucous pastern dermatitis. A combination of sharp dissection and electrocautery was used to resect numerous multifocal circumscribed verrucous masses from the distal hindlimb of an 11-year-old gelding draught horse. There was no evidence of significant regrowth or complications at a 24 month postoperative examination. © 2011 The Authors. Veterinary Dermatology. © 2011 ESVD and ACVD.
Vision and falls in older people: risk factors and intervention strategies.
Lord, Stephen R; Smith, Stuart T; Menant, Jasmine C
2010-11-01
Poor vision impairs balance and increases the risk of falls and fractures in older people. Multifocal glasses can add to this risk by impairing contrast sensitivity, depth perception, and ability to negotiate obstacles. Vision assessment and provision of new spectacles may not reduce, and may even increase, the risk of falls. Restriction of the use of multifocal glasses may reduce falls in active older people. Other effective fall prevention strategies include maximizing vision through cataract surgery and occupational therapy interventions in visually impaired older people. Copyright © 2010 Elsevier Inc. All rights reserved.
Mundo, J; Peris, P; Monegal, A; Navasa, M; Cervera, R; Guañiabens, N
2006-01-01
We describe the case of a 31-year-old man who presented with an antiphospholipid syndrome (APS), which manifested as multifocal avascular necrosis (AVN) one year after orthotopic liver transplantation. The patient developed multiple AVN affecting hips, left knee, humerus and tarsal bones just after withdrawal of corticosteroid therapy. Three years later when lupus anticoagulant was detected, he began anticoagulant treatment and no further AVN episodes were observed. It is important to be aware of this clinical manifestation of APS, especially in these cases where it can be easily overlooked because of corticosteroid therapy.
Generation of multifocal irradiance patterns by using complex Fresnel holograms.
Mendoza-Yero, Omel; Carbonell-Leal, Miguel; Mínguez-Vega, Gladys; Lancis, Jesús
2018-03-01
We experimentally demonstrate Fresnel holograms able to produce multifocal irradiance patterns with micrometric spatial resolution. These holograms are assessed from the coherent sum of multiple Fresnel lenses. The utilized encoded technique guarantees full control over the reconstructed irradiance patterns due to an optimal codification of the amplitude and phase information of the resulting complex field. From a practical point of view, a phase-only spatial light modulator is used in a couple of experiments addressed to obtain two- and three-dimensional distributions of focal points to excite both linear and non-linear optical phenomena.
NASA Astrophysics Data System (ADS)
Krauß, T.
2014-11-01
The focal plane assembly of most pushbroom scanner satellites is built up in a way that different multispectral or multispectral and panchromatic bands are not all acquired exactly at the same time. This effect is due to offsets of some millimeters of the CCD-lines in the focal plane. Exploiting this special configuration allows the detection of objects moving during this small time span. In this paper we present a method for automatic detection and extraction of moving objects - mainly traffic - from single very high resolution optical satellite imagery of different sensors. The sensors investigated are WorldView-2, RapidEye, Pléiades and also the new SkyBox satellites. Different sensors require different approaches for detecting moving objects. Since the objects are mapped on different positions only in different spectral bands also the change of spectral properties have to be taken into account. In case the main distance in the focal plane is between the multispectral and the panchromatic CCD-line like for Pléiades an approach for weighted integration to receive mostly identical images is investigated. Other approaches for RapidEye and WorldView-2 are also shown. From these intermediate bands difference images are calculated and a method for detecting the moving objects from these difference images is proposed. Based on these presented methods images from different sensors are processed and the results are assessed for detection quality - how many moving objects can be detected, how many are missed - and accuracy - how accurate is the derived speed and size of the objects. Finally the results are discussed and an outlook for possible improvements towards operational processing is presented.
Strategic options towards an affordable high-performance infrared camera
NASA Astrophysics Data System (ADS)
Oduor, Patrick; Mizuno, Genki; Dutta, Achyut K.; Lewis, Jay; Dhar, Nibir K.
2016-05-01
The promise of infrared (IR) imaging attaining low-cost akin to CMOS sensors success has been hampered by the inability to achieve cost advantages that are necessary for crossover from military and industrial applications into the consumer and mass-scale commercial realm despite well documented advantages. Banpil Photonics is developing affordable IR cameras by adopting new strategies to speed-up the decline of the IR camera cost curve. We present a new short-wave IR (SWIR) camera; 640x512 pixel InGaAs uncooled system that is high sensitivity low noise (<50e-), high dynamic range (100 dB), high-frame rates (> 500 frames per second (FPS)) at full resolution, and low power consumption (< 1 W) in a compact system. This camera paves the way towards mass market adoption by not only demonstrating high-performance IR imaging capability value add demanded by military and industrial application, but also illuminates a path towards justifiable price points essential for consumer facing application industries such as automotive, medical, and security imaging adoption. Among the strategic options presented include new sensor manufacturing technologies that scale favorably towards automation, multi-focal plane array compatible readout electronics, and dense or ultra-small pixel pitch devices.
Kinematic measurement from panned cinematography.
Gervais, P; Bedingfield, E W; Wronko, C; Kollias, I; Marchiori, G; Kuntz, J; Way, N; Kuiper, D
1989-06-01
Traditional 2-D cinematography has used a stationary camera with its optical axis perpendicular to the plane of motion. This method has constrained the size of the object plane or has introduced potential errors from a small subject image size with large object field widths. The purpose of this study was to assess a panning technique that could overcome the inherent limitations of small object field widths, small object image sizes and limited movement samples. The proposed technique used a series of reference targets in the object field that provided the necessary scales and origin translations. A 102 m object field was panned. Comparisons between criterion distances and film measured distances for field widths of 46 m and 22 m resulted in absolute mean differences that were comparable to that of the traditional method.
NASA Astrophysics Data System (ADS)
Zhao, Yuchen; Zemmamouche, Redouane; Vandenrijt, Jean-François; Georges, Marc P.
2018-05-01
A combination of digital holographic interferometry (DHI) and digital speckle photography (DSP) allows in-plane and out-of-plane displacement measurement between two states of an object. The former can be determined by correlating the two speckle patterns whereas the latter is given by the phase difference obtained from DHI. We show that the amplitude of numerically reconstructed object wavefront obtained from Fresnel in-line digital holography (DH), in combination with phase shifting techniques, can be used as speckle patterns in DSP. The accuracy of in-plane measurement is improved after correcting the phase errors induced by reference wave during reconstruction process. Furthermore, unlike conventional imaging system, Fresnel DH offers the possibility to resize the pixel size of speckle patterns situated on the reconstruction plane under the same optical configuration simply by zero-padding the hologram. The flexibility of speckle size adjustment in Fresnel DH ensures the accuracy of estimation result using DSP.
Investigating the Free-Body Diagram of a Stationary Object on an Inclined Plane Using Apple Watch
ERIC Educational Resources Information Center
Dilek, Ufuk; Çaliskan, Serap
2017-01-01
In this study, we present an activity in which the free-body diagram of a real stationary object on an inclined plane can be examined interactively. We use an Apple Watch and a few other materials that can be accessed easily. Instead of an Apple Watch, a mobile phone or a tablet could also be used. This activity may be employed to introduce the…
The Relationship Between KBO Colors and Kuiper-belt Plane Inclination
NASA Astrophysics Data System (ADS)
Kane, J. F.; Gulbis, A. A. S.; Elliot, J. L.
2005-08-01
The colors of Kuiper belt objects (KBOs) can indicate different compositions, environmental conditions, or formation characteristics within the Kuiper belt. Photometric color observations of these objects, combined with dynamical information, can provide insight into their composition, the extent to which space-weathering or impact gardening have played a role in surface modification, and the processes at work during the formation of our solar system. Data from the Deep Ecliptic Survey (DES; Millis et al., 2002, AJ, 123, 2083) have been used to determine the plane of the Kuiper belt, identifying "core" and "halo" populations with respect to this plane (Elliot et al. 2005, AJ, 129, 1117). Gulbis et al. (2005, Icarus, submitted) found the colors of the core KBOs, those having inclinations within approximately 4.6 degrees of the Kuiper-belt plane, to be primarily red, unlike the halo objects. We have combined newly obtained Sloan g', r', and i' observations from the 6.5-m Clay telescope at Las Campanas Observatory of 12 KBOs with previously published data to examine the transition between these populations as a function of color. By comparing the colors of objects as a function of inclination, we can establish trends distinguishing the core and halo populations. For inclination bins containing equal numbers of KBOs, we find that the percentage of red objects (B-R > median B-R of the sample) decreases in a smooth, but nonlinear fashion. This research is partially supported by an MIT fellowship, an NSF GSRF and NSF grant AST0406493.
Multifocal electroretinograms.
Creel, Donnell J
2011-12-04
A limitation of traditional full-field electroretinograms (ERG) for the diagnosis of retinopathy is lack of sensitivity. Generally, ERG results are normal unless more than approximately 20% of the retina is affected. In practical terms, a patient might be legally blind as a result of macular degeneration or other scotomas and still appear normal, according to traditional full field ERG. An important development in ERGs is the multifocal ERG (mfERG). Erich Sutter adapted the mathematical sequences called binary m-sequences enabling the isolation from a single electrical signal an electroretinogram representing less than each square millimeter of retina in response to a visual stimulus. Results that are generated by mfERG appear similar to those generated by flash ERG. In contrast to flash ERG, which best generates data appropriate for whole-eye disorders. The basic mfERG result is based on the calculated mathematical average of an approximation of the positive deflection component of traditional ERG response, known as the b-wave. Multifocal ERG programs measure electrical activity from more than a hundred retinal areas per eye, in a few minutes. The enhanced spatial resolution enables scotomas and retinal dysfunction to be mapped and quantified. In the protocol below, we describe the recording of mfERGs using a bipolar speculum contact lens. Components of mfERG systems vary between manufacturers. For the presentation of visible stimulus, some suitable CRT monitors are available but most systems have adopted the use of flat-panel liquid crystal displays (LCD). The visual stimuli depicted here, were produced by a LCD microdisplay subtending 35-40 degrees horizontally and 30-35 degrees vertically of visual field, and calibrated to produce multifocal flash intensities of 2.7 cd s m(-2). Amplification was 50K. Lower and upper bandpass limits were 10 and 300 Hz. The software packages used were VERIS versions 5 and 6.
Lindstrom, R L
1993-01-01
The clinical evaluation of the Food and Drug Administration study of the 3M diffractive multifocal intraocular lens (IOL) is presented here to demonstrate the results of 1-year postoperative data accumulated for 671 patients, the first of whom received the implant in 1987. Patients were selected for study if they had absence of preoperative pathology, were at least 60 years of age, and had a reasonable postoperative prognosis. Extensive evaluations took place at 4 to 6 months and 12 to 14 months after surgery, including five different visual acuity measurements and contrast sensitivity. All testing was completed on both eyes. Data from the fellow eye served as a control when implanted with a monofocal IOL. Overall uncorrected distance visual acuity at 1 year after surgery shows 57% patients with 20/40 or better acuity. In this same group, 78% achieved J3 or better near vision, which improved to 82% in the best case group. Uncorrected visual acuity of 20/40 or better and J3 or better was achieved by 50% of best case multifocal IOL patients, compared with 26% of the monofocal best case comparison group. Measurements of contrast sensitivity consistently document a small loss, which is considered clinically insignificant. Statistical analysis of satisfaction ratings shows that predictors of satisfaction include uncorrected distance acuity, final near acuity, and fellow eye spherical equivalent. This multifocal lens appears to work very well for most patients, with more than half having functional uncorrected distance and near vision. The study showed several considerations that are important for optimizing clinical performance and patient satisfaction: patient selection, realistic expectations, accurate biometry, and adequate control of surgical procedures.
Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens.
van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J; Mourits, Maarten P; Lapid-Gortzak, Ruth
2014-12-01
To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312 MF30, Oculentis, Germany). At 3 months postoperatively, the AR and MR values were compared to determine the correlation between the sphere (S), the spherical equivalent (SE) and the astigmatic components J0 and J45. The difference of mean spherical measurement was +0.98D ± 0.62, with the AR measuring more myopic. The difference of the mean spherical equivalent was +1.11D ± 0.57, again with AR being more myopic. Both these differences were statistically significant (p < 0.001). The astigmatic components showed less differences, with the mean difference of the J0 being -0.09D ± 0.43, and the J45 of +0.04D ± 0.47, which were both not statistically significant (p = 0.123 and p = 0.531, respectively). Correlation analysis of the refractive parameters showed r(2) = 0.067, r(2) = 0.078, r(2) = 0.018 and r(2) = 0.015, respectively, all of which point to a low correlation between the AR and the MR. Autorefraction shows poor correlation to manifest subjective refraction with these radially asymmetric multifocal IOLs. The autorefraction systematically underestimates the spherical and spherical equivalent power, while the correlation between the astigmatic components was also low. Autorefraction seems not a valid starting point for manifest subjective refraction with these types of lenses, unless a corrective factor of about +1 dioptre is used. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Peripheral refraction with eye and head rotation with contact lenses.
Lopes-Ferreira, Daniela P; Neves, Helena I F; Faria-Ribeiro, Miguel; Queirós, António; Fernandes, Paulo R B; González-Méijome, José M
2015-04-01
To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Nineteen right eyes from 19 myopic patients (average central M ± SD = -2.67 ± 1.66 D) aged 20-27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D(®)) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. For the naked eye, refractive pattern (M, J0 and J45) across the central 60° of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J
2012-02-01
To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.
Linz, Katharina; Attia, Mary S A; Khoramnia, Ramin; Tandogan, Tamer; Kretz, Florian T; Auffarth, Gerd Uwe
2016-08-01
To evaluate functional results and reading performance using the Salzburg Reading Desk after implantation of a sector-shaped near-embedded, rotational asymmetrical multifocal intraocular lens (IOL) and a multifocal toric IOL with a +3.00 diopter (D) near addition. In a prospective study, the LentisMplus and Mplus toric IOLs (Oculentis GmbH, Berlin, Germany) were implanted in 34 eyes of 18 patients at the University Eye Hospital of Heidelberg. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected and corrected near visual acuity (UNVA, CNVA) were evaluated using standardized visual acuity charts (ETDRS). The Salzburg Reading Desk was used to analyze unilateral and bilateral uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at a set (40 cm/80 cm) and subjective chosen near and intermediate distance. Postoperatively, the median UDVA was 0.08 logMAR (20/25 Snellen) and the median CDVA was 0.01 logMAR (20/20 Snellen). The median UNVA was 0.12 logMAR (20/25 Snellen) and the median CNVA was 0.03 logMAR (20/20 Snellen). The median uncorrected reading acuity measured with the Salzburg Reading Desk for near distance at 40 cm was 0.18 logMAR (20/32 Snellen). The subjectively preferred near distance was 39 cm and revealed similar visual acuity results. The best reading acuity for intermediate distance with a median of 0.22 logMAR (20/32 Snellen) was achieved at a median distance of 62 cm. Reading performance of the multifocal IOL corresponded for near standardized and individual distance, whereas reading function was better at the patient's preferred intermediate distance. [J Refract Surg. 2016;32(8):526-532.]. Copyright 2016, SLACK Incorporated.
Bakaraju, Ravi C; Ehrmann, Klaus; Ho, Arthur
To compare the computed optical performance of prototype lenses designed using deliberate manipulation of higher-order spherical aberrations to extend depth-of-focus (EDOF) with two commercial multifocals. Emmetropic, presbyopic, schematic eyes were coupled with prototype EDOF and commercial multifocal lenses (Acuvue Oasys for presbyopia, AOP, Johnson & Johnson & Air Optix Aqua multifocal, AOMF, Alcon). For each test configuration, the through-focus retinal image quality (TFRIQ) values were computed over 21 vergences, ranging from -0.50 to 2.00D, in 0.125D steps. Analysis was performed considering eyes with three different inherent aberration profiles: five different pupils and five different lens decentration levels. Except the LOW design, the AOP lenses offered 'bifocal' like TFRIQ performance. Lens performance was relatively independent to pupil and aberrations but not centration. Contrastingly, AOMF demonstrated distance centric performance, most dominant in LOW followed by MED and HIGH designs. AOMF lenses were the most sensitive to pupil, aberrations and centration. The prototypes demonstrated a 'lift-off' in the TFRIQ performance, particularly at intermediate and near, without trading performance at distance. When compared with AOP and AOMF, EDOF lenses demonstrated reduced sensitivity to pupil, aberrations and centration. With the through focus retinal image quality as the gauge of optical performance, we demonstrated that the prototype EDOF designs were less susceptible to variations in pupil, inherent ocular aberrations and decentration, compared to the commercial designs. To ascertain whether these incremental improvements translate to a clinically palpable outcome requires investigation through human trials. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Baker, T F; McEwen, S A; Prescott, J F; Meek, A H
1989-01-01
An abattoir survey was undertaken to determine the prevalence of leptospirosis and its association with lesions of multifocal interstitial nephritis (so-called "white spotted kidneys") in swine at slaughter. Both cross-sectional and case-control study designs were used. Of 197 kidneys from hogs randomly selected at slaughter, 11 (5.6%) had generalized grey-white foci typical of multifocal interstitial nephritis (MFIN). Antibody titers greater than or equal to 1:80 against Leptospira pomona were detected in nine (4.6%) hogs and against L. bratislava in 63 (32%) of these hogs. Leptospira pomona (kennewicki) was detected by immunofluorescence in 5/197 (2.5%) of randomly selected hogs. Leptospires identified as genotype kennewicki were isolated from six (9.8%) of 61 kidneys cultured. Leptospira bratislava was not detected by immunofluorescence or culture. There was a highly significant (p = 0.00) and strong association (odds ratio (OR) = 195) between high L. pomona titer (greater than or equal to 1:80) and the presence of leptospires in the kidneys, as detected by culture. There was also a significant (p = 0.046) and strong (OR = 8.10) association between multifocal interstitial nephritis and the presence of renal leptospires as detected by culture. The association between leptospiral titer and MFIN lesions in the prevalence survey group of animals was statistically significant (p = 0.031), but this association was not significant in the case-control study group (p = 0.071) The failure to identify L. bratislava despite serological evidence of infection suggests that some of these seropositive animals may have been transiently infected at an early age, that serological findings were falsely positive, or that immunofluorescence and isolation attempts failed to detect L. bratislava if they were indeed present in the kidneys.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2766150
De Ley, Paul; De Ley, Irma Tandingan; Morris, Krystalynne; Abebe, Eyualem; Mundo-Ocampo, Manuel; Yoder, Melissa; Heras, Joseph; Waumann, Dora; Rocha-Olivares, Axayácatl; Jay Burr, A.H; Baldwin, James G; Thomas, W. Kelley
2005-01-01
Molecular surveys of meiofaunal diversity face some interesting methodological challenges when it comes to interstitial nematodes from soils and sediments. Morphology-based surveys are greatly limited in processing speed, while barcoding approaches for nematodes are hampered by difficulties of matching sequence data with traditional taxonomy. Intermediate technology is needed to bridge the gap between both approaches. An example of such technology is video capture and editing microscopy, which consists of the recording of taxonomically informative multifocal series of microscopy images as digital video clips. The integration of multifocal imaging with sequence analysis of the D2D3 region of large subunit (LSU) rDNA is illustrated here in the context of a combined morphological and barcode sequencing survey of marine nematodes from Baja California and California. The resulting video clips and sequence data are made available online in the database NemATOL (http://nematol.unh.edu/). Analyses of 37 barcoded nematodes suggest that these represent at least 32 species, none of which matches available D2D3 sequences in public databases. The recorded multifocal vouchers allowed us to identify most specimens to genus, and will be used to match specimens with subsequent species identifications and descriptions of preserved specimens. Like molecular barcodes, multifocal voucher archives are part of a wider effort at structuring and changing the process of biodiversity discovery. We argue that data-rich surveys and phylogenetic tools for analysis of barcode sequences are an essential component of the exploration of phyla with a high fraction of undiscovered species. Our methods are also directly applicable to other meiofauna such as for example gastrotrichs and tardigrades. PMID:16214752
Jiang, Weiqin; Shen, Yifei; Ding, Yongfeng; Ye, Chuyu; Zheng, Yi; Zhao, Peng; Liu, Lulu; Tong, Zhou; Zhou, Linfu; Sun, Shuo; Zhang, Xingchen; Teng, Lisong; Timko, Michael P; Fan, Longjiang; Fang, Weijia
2018-01-15
Synchronous multifocal tumors are common in the hepatobiliary and pancreatic system but because of similarities in their histological features, oncologists have difficulty in identifying their precise tissue clonal origin through routine histopathological methods. To address this problem and assist in more precise diagnosis, we developed a computational approach for tissue origin diagnosis based on naive Bayes algorithm (TOD-Bayes) using ubiquitous RNA-Seq data. Massive tissue-specific RNA-Seq data sets were first obtained from The Cancer Genome Atlas (TCGA) and ∼1,000 feature genes were used to train and validate the TOD-Bayes algorithm. The accuracy of the model was >95% based on tenfold cross validation by the data from TCGA. A total of 18 clinical cancer samples (including six negative controls) with definitive tissue origin were subsequently used for external validation and 17 of the 18 samples were classified correctly in our study (94.4%). Furthermore, we included as cases studies seven tumor samples, taken from two individuals who suffered from synchronous multifocal tumors across tissues, where the efforts to make a definitive primary cancer diagnosis by traditional diagnostic methods had failed. Using our TOD-Bayes analysis, the two clinical test cases were successfully diagnosed as pancreatic cancer (PC) and cholangiocarcinoma (CC), respectively, in agreement with their clinical outcomes. Based on our findings, we believe that the TOD-Bayes algorithm is a powerful novel methodology to accurately identify the tissue origin of synchronous multifocal tumors of unknown primary cancers using RNA-Seq data and an important step toward more precision-based medicine in cancer diagnosis and treatment. © 2017 UICC.
Testing vision with angular and radial multifocal designs using Adaptive Optics.
Vinas, Maria; Dorronsoro, Carlos; Gonzalez, Veronica; Cortes, Daniel; Radhakrishnan, Aiswaryah; Marcos, Susana
2017-03-01
Multifocal vision corrections are increasingly used solutions for presbyopia. In the current study we have evaluated, optically and psychophysically, the quality provided by multizone radial and angular segmented phase designs. Optical and relative visual quality were evaluated using 8 subjects, testing 6 phase designs. Optical quality was evaluated by means of Visual Strehl-based-metrics (VS). The relative visual quality across designs was obtained through a psychophysical paradigm in which images viewed through 210 pairs of phase patterns were perceptually judged. A custom-developed Adaptive Optics (AO) system, including a Hartmann-Shack sensor and an electromagnetic deformable mirror, to measure and correct the eye's aberrations, and a phase-only reflective Spatial Light Modulator, to simulate the phase designs, was developed for this study. The multizone segmented phase designs had 2-4 zones of progressive power (0 to +3D) in either radial or angular distributions. The response of an "ideal observer" purely responding on optical grounds to the same psychophysical test performed on subjects was calculated from the VS curves, and compared with the relative visual quality results. Optical and psychophysical pattern-comparison tests showed that while 2-zone segmented designs (angular & radial) provided better performance for far and near vision, 3- and 4-zone segmented angular designs performed better for intermediate vision. AO-correction of natural aberrations of the subjects modified the response for the different subjects but general trends remained. The differences in perceived quality across the different multifocal patterns are, in a large extent, explained by optical factors. AO is an excellent tool to simulate multifocal refractions before they are manufactured or delivered to the patient, and to assess the effects of the native optics to their performance. Copyright © 2016 Elsevier Ltd. All rights reserved.
Multifocal tumoral calcinosis in a 4-year-old girl
Sayar, Ilyas; Peker, Kemal; Kapısız, Alparslan; Bostancı, Isıl Esen; Gürbüzel, Mehmet; Isik, Arda; Peker, Necla Aydın
2014-01-01
Patient: Female, 4 Final Diagnosis: Tumoral calcinosis Symptoms: Hard immobile mass Medication: — Clinical Procedure: — Specialty: Surgery Objective: Congenital defects Background: Tumoral calcinosis is an uncommon condition associated with the deposition of painless calcific masses. It is more common in childhood or early adolescence of African-American females. Case Report: We present a case of a 4-year-old girl with tumoral calcinosis treated surgically. The case is rather rare in terms of the age of the patient and the localization of the masses (gluteal site). In our patient, the biochemical findings were normal, except for hyperphosphatemia and elevated alkaline phosphatase. Conclusions: Total excision appears to lead to a good clinical outcome and a low incidence of local relapse. PMID:24644527
Miniaturized Fourier-plane fiber scanner for OCT endoscopy
NASA Astrophysics Data System (ADS)
Vilches, Sergio; Kretschmer, Simon; Ataman, Çağlar; Zappe, Hans
2017-10-01
A forward-looking endoscopic optical coherence tomography (OCT) probe featuring a Fourier-plane fiber scanner is designed, manufactured and characterized. In contrast to common image-plane fiber scanners, the Fourier-plane scanner is a telecentric arrangement that eliminates vignetting and spatial resolution variations across the image plane. To scan the OCT beam in a spiral pattern, a tubular piezoelectric actuator is used to resonate an optical fiber bearing a collimating GRIN lens at its tip. The free-end of the GRIN lens sits at the back focal plane of an objective lens, such that its rotation replicates the beam angles in the collimated region of a classical telecentric 4f optical system. Such an optical arrangement inherently has a low numerical aperture combined with a relatively large field-of-view, rendering it particularly useful for endoscopic OCT imaging. Furthermore, the optical train of the Fourier-plane scanner is shorter than that of a comparable image-plane scanner by one focal length of the objective lens, significantly shortening the final arrangement. As a result, enclosed within a 3D printed housing of 2.5 mm outer diameter and 15 mm total length, the developed probe is the most compact forward-looking endoscopic OCT imager to date. Due to its compact form factor and compatibility with real-time OCT imaging, the developed probe is also ideal for use in the working channel of flexible endoscopes as a potential optical biopsy tool.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rolison, L; Samant, S; Baciak, J
Purpose: To develop a Monte Carlo N-Particle (MCNP) model for the validation of a prototype backscatter x-ray (BSX) imager, and optimization of BSX technology for medical applications, including selective object-plane imaging. Methods: BSX is an emerging technology that represents an alternative to conventional computed tomography (CT) and projective digital radiography (DR). It employs detectors located on the same side as the incident x-ray source, making use of backscatter and avoiding ring geometry to enclose the imaging object. Current BSX imagers suffer from low spatial resolution. A MCNP model was designed to replicate a BSX prototype used for flaw detection inmore » industrial materials. This prototype consisted of a 1.5mm diameter 60kVp pencil beam surrounded by a ring of four 5.0cm diameter NaI scintillation detectors. The imaging phantom consisted of a 2.9cm thick aluminum plate with five 0.6cm diameter holes drilled halfway. The experimental image was created using a raster scanning motion (in 1.5mm increments). Results: A qualitative comparison between the physical and simulated images showed very good agreement with 1.5mm spatial resolution in plane perpendicular to incident x-ray beam. The MCNP model developed the concept of radiography by selective plane detection (RSPD) for BSX, whereby specific object planes can be imaged by varying kVp. 10keV increments in mean x-ray energy yielded 4mm thick slice resolution in the phantom. Image resolution in the MCNP model can be further increased by increasing the number of detectors, and decreasing raster step size. Conclusion: MCNP modelling was used to validate a prototype BSX imager and introduce the RSPD concept, allowing for selective object-plane imaging. There was very good visual agreement between the experimental and MCNP imaging. Beyond optimizing system parameters for the existing prototype, new geometries can be investigated for volumetric image acquisition in medical applications. This material is based upon work supported under an Integrated University Program Graduate Fellowship sponsored by the Department of Energy Office of Nuclear Energy.« less
The DECam Plane Survey: Optical Photometry of Two Billion Objects in the Southern Galactic Plane
NASA Astrophysics Data System (ADS)
Schlafly, E. F.; Green, G. M.; Lang, D.; Daylan, T.; Finkbeiner, D. P.; Lee, A.; Meisner, A. M.; Schlegel, D.; Valdes, F.
2018-02-01
The DECam Plane Survey is a five-band optical and near-infrared survey of the southern Galactic plane with the Dark Energy Camera at Cerro Tololo. The survey is designed to reach past the main-sequence turn-off of old populations at the distance of the Galactic center through a reddening E(B-V) of 1.5 mag. Typical single-exposure depths are 23.7, 22.8, 22.3, 21.9, and 21.0 mag (AB) in the grizY bands, with seeing around 1\\prime\\prime . The footprint covers the Galactic plane with | b| ≲ 4^\\circ , 5^\\circ > l> -120^\\circ . The survey pipeline simultaneously solves for the positions and fluxes of tens of thousands of sources in each image, delivering positions and fluxes of roughly two billion stars with better than 10 mmag precision. Most of these objects are highly reddened and deep in the Galactic disk, probing the structure and properties of the Milky Way and its interstellar medium. The fully-processed images and derived catalogs are publicly available.
NASA Technical Reports Server (NTRS)
Tandberg-Hanssen, E. A. (Editor); Hudson, H. S. (Editor); Dabbs, J. R. (Editor); Baity, W. A. (Editor)
1983-01-01
Scientific objectives and requirements are discussed for solar X-ray observations, coronagraph observations, studies of coronal particle acceleration, and cosmic X-ray observations. Improved sensitivity and resolution can be provided for these studies using the pinhole/occulter facility which consists of a self-deployed boom of 50 m length separating an occulter plane from a detector plane. The X-ray detectors and coronagraphic optics mounted on the detector plane are analogous to the focal plane instrumentation of an ordinary telescope except that they use the occulter only for providing a shadow pattern. The occulter plane is passive and has no electrical interface with the rest of the facility.
Epigenetic age analysis of children who seem to evade aging.
Walker, Richard F; Liu, Jia Sophie; Peters, Brock A; Ritz, Beate R; Wu, Timothy; Ophoff, Roel A; Horvath, Steve
2015-05-01
We previously reported the unusual case of a teenage girl stricken with multifocal developmental dysfunctions whose physical development was dramatically delayed resulting in her appearing to be a toddler or at best a preschooler, even unto the occasion of her death at the age of 20 years. Her life-long physician felt that the disorder was unique in the world and that future treatments for age-related diseases might emerge from its study. The objectives of our research were to determine if other such cases exist, and if so, whether aging is actually slowed. Of seven children characterized by dramatically slow developmental rates, five also had associated disorders displayed by the first case. All of the identified subjects were female. To objectively measure the age of blood tissue from these subjects, we used a highly accurate biomarker of aging known as "epigenetic clock" based on DNA methylation levels. No statistically significant differences in chronological and epigenetic ages were detected in any of the newly discovered cases.
Ider, Yusuf Ziya; Birgul, Ozlem; Oran, Omer Faruk; Arikan, Orhan; Hamamura, Mark J; Muftuler, L Tugan
2010-06-07
Fourier transform (FT)-based algorithms for magnetic resonance current density imaging (MRCDI) from one component of magnetic flux density have been developed for 2D and 3D problems. For 2D problems, where current is confined to the xy-plane and z-component of the magnetic flux density is measured also on the xy-plane inside the object, an iterative FT-MRCDI algorithm is developed by which both the current distribution inside the object and the z-component of the magnetic flux density on the xy-plane outside the object are reconstructed. The method is applied to simulated as well as actual data from phantoms. The effect of measurement error on the spatial resolution of the current density reconstruction is also investigated. For 3D objects an iterative FT-based algorithm is developed whereby the projected current is reconstructed on any slice using as data the Laplacian of the z-component of magnetic flux density measured for that slice. In an injected current MRCDI scenario, the current is not divergence free on the boundary of the object. The method developed in this study also handles this situation.
Multifocal necrotising fasciitis and septic shock complicating varicella infection in an adult
Mifsud, Simon; Schembri, Emma Louise; Mallia Azzopardi, Charles; Zammit, Maria Alessandra
2013-01-01
A 35-year-old woman with a 3-day history of chickenpox, presented to the hospital in septic shock and with multifocal, non-adjacent lesions of necrotising fasciitis. Necrotising fasciitis is a rare yet life-threatening complication of chickenpox. Blood cultures and wound swabs confirmed the presence of Streptococcus pyogenes. The initial emergency management included oxygen, aggressive fluid resuscitation and antimicrobial therapy. Once the patient was stabilised, surgical management ensued. This included debridement and eventual grafting of the necrotic skin lesions. Intensive management and follow-up for 8 weeks were required before the patient was deemed fit for discharge. PMID:24130210
Acute posterior multifocal placoid pigment epitheliopathy associated with cerebral vasculitis.
Weinstein, J M; Bresnick, G H; Bell, C L; Roschmann, R A; Brooks, B R; Strother, C M
1988-09-01
Acute multifocal posterior placoid pigment epitheliopathy (APMPPE) is an unusual self-limited retinal disorder that has been associated with various systemic complications. To our knowledge, three prior cases associated with cerebral vasculitis have been described. This article describes a patient with APMPPE and angiographically documented cerebral vasculitis who was notable because of (a) the presence of two different cerebral ischemic events, occurring 1 month apart, and (b) the long latency (3 months) between the onset of ocular symptoms and the second cerebral ischemic event. Recognition of the association between APMPPE and cerebral vasculitis may permit early treatment of CNS involvement and prevention of morbidity.
Hereditary Neuropathy With Liability to Pressure Palsies: Diverse Phenotypes in Childhood.
Harada, Yohei; Puwanant, Araya; Herrmann, David N
2016-12-01
Hereditary neuropathy with liability to pressure palsies (HNPP) is a rare autosomal-dominant disorder that most commonly produces recurrent painless focal sensory and motor neuropathies often preceded by minor, mechanical stress, or minor trauma. Herein, we report 2 pediatric cases of HNPP with atypical presentations; isolated muscle cramping and toe walking. Electrophysiologic testing disclosed multifocal sensorimotor polyneuropathy with slowing of sensory conduction velocities in both cases, which prompted PMP 22 gene deletion testing. Multifocal sensorimotor electrophysiologic abnormalities, with slowing of sensory conduction velocities should raise consideration of HNPP in childhood. These case reports emphasize that the diagnosis of HNPP in children requires a high index of suspicion.
Beppu, Minako; Kawamoto, Michi; Nukuzuma, Souichi; Kohara, Nobuo
2012-01-01
We describe a case of a 67-year-old man with systemic lupus erythematosus who presented with progressive left hemiplegia. Although the cerebral spinal fluid (CSF) polymerase chain reaction (PCR) for the JC virus was negative, a brain biopsy confirmed the diagnosis of progressive multifocal leukoencephalopathy (PML). The tapering of prednisone and the use of cidofovir could not arrest the disease progression. Administration of mefloquine stopped the extension of the lesion, and resulted in obvious clinical improvement. The CSF nested PCR for the JC virus also became negative. This widely used drug should be tried for the treatment of non-HIV PML.
Multifocal Renal Fungal Abscesses.
Cho, Eric Y; Kaplan, Joshua R; Mamone, Linda; Mydlo, Jack H; Reese, Adam C
2016-07-01
We report a case of multiple fungal renal abscesses in a 36-year-old woman with a history of diabetes and intravenous substance use disorder. The patient presented with fever and hematuria, and was found to be bacteremic and fungemic. She was initially managed with broad-spectrum antibiotics and antifungals. She remained febrile and imaging on treatment day 14 showed no improvement of the renal abscesses. Thus, a nephrectomy was performed, after which the patient defervesced and follow-up blood cultures were negative. There is a paucity of literature regarding management of multifocal fungal renal abscesses that fail to respond to medical management. Copyright © 2016 Elsevier Inc. All rights reserved.
Progressive Multifocal Leukoencephalopathy: Recent Advances and a Neuro-Ophthalmological Review.
Sudhakar, Padmaja; Bachman, David M; Mark, Alexander S; Berger, Joseph R; Kedar, Sachin
2015-09-01
Progressive multifocal leukoencephalopathy (PML) is a severe often fatal opportunistic infection of the central nervous system caused by reactivation of a ubiquitous polyoma virus, JC virus. Although typically characterized by multifocal asymmetric subcortical white matter lesions, it may be monofocal and affect the cortical gray matter. Among the broad spectrum of clinical manifestations that occurs with PML, visual complaints are common. Combination of representative personally observed cases of PML and comprehensive review of case series of PML from 1958 through 2014. Neuro-ophthalmic signs and symptoms were reported in approximately 20%-50% of patients with PML and can be the presenting manifestation in half of these. A majority of these presentations occur from damage to cerebral visual pathways resulting in visual field defects, cortical blindness, and other disorders of visual association. Given the decreased frequency of infratentorial and cerebellar involvement, ocular motility disorders are less common. Visual complaints occur in patients with PML and are often the presenting sign. Awareness of this condition is helpful in avoiding unnecessary delays in the diagnosis of PML and management of the underlying condition. Recent guidelines have established criteria for diagnosis of PML in the high-risk patient population and strategies to mitigate the risk in these populations.
Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P
2012-04-01
To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.
Protothecal granulomatous meningoencephalitis in a dog.
Salvadori, C; Gandini, G; Ballarini, A; Cantile, C
2008-10-01
A case of central nervous system protothecosis in a dog is reported. A three-year-old male Maremma sheepdog was referred with a two month history of diarrhoea associated with progressive tetraparesis, depression and right circling. Stupor, severe proprioceptive deficits, bilateral decreased thoracic limb flexor reflexes and bilateral deficit of the menace reaction were detected on neurological examination and a multi-focal neurological localisation was suspected. Histopathological evaluation revealed multi-focal granulomatous foci in the thalamus, hippocampus and caudal brainstem containing numerous oval-rounded organisms with a thick, periodic acid-Schiff-positive and Gomori's methenamine silver-positive cell wall, a basophilic cytoplasm and one nucleus. Scattered sporangia containing two to four endospores were also observed. Morphological features were consistent with Prototheca species. Ultrastructurally, numerous degenerated algae were present within macrophages mainly lacking nuclei and cytoplasmic organelles. Generally, protothecosis in dogs is characterised by systemic signs because of a multi-organ involvement, and haemorrhagic colitis or ophthalmologic signs are the most frequent presenting signs. However, protothecosis should be added, also in Europe, to the list of the differential diagnoses in adult dogs with a multi-focal neurological localisation even in absence of other clinical signs.
Yoshino, Mami; Minami, Keiichiro; Hirasawa, Manabu; Oki, Shinichi; Bissen-Miyajima, Hiroko
2015-09-01
To evaluate the visual performance in eyes with diffractive intraocular lenses (IOLs) after laser in situ keratomileusis (LASIK). This single-center retrospective study evaluated eyes that had diffractive multifocal IOL implantation after previous LASIK or not treated with LASIK (controls). The outcomes' measures were the visual acuities (VAs) at distance and near, spherical equivalent (SE) and contrast sensitivity at one month postoperatively. The study evaluated 40 eyes of 33 patients. The mean uncorrected logMAR VAs were -0.05 ± 0.13/0.00 ± 0.14 (LASIK group/control group) at distance and 0.10 ± 0.13/0.16 ± 0.18 at near. There was no statistically significant difference between the 2 groups at the VAs. The SE of the LASIK group was -0.06 ± 0.39 D, significantly lower than the control group (0.22 ± 0.45 D) (p < 0.05). The contrast sensitivity of the LASIK group at high spatial frequency was lower than the control group (p < 0.05). After LASIK, the diffractive multifocal IOL provided good uncorrected distance and near VAs. However, decrease in contrast sensitivity should be considered.
Seiple, William; Szlyk, Janet P; Paliga, Jennifer; Rabb, Maurice F
2006-04-01
To quantify the extent of visual function losses in patients with North Carolina Macular Dystrophy (NCMD) and to demonstrate the importance of accounting for eccentric fixation when making comparisons with normal data. Five patients with NCMD who were from a single family were examined. Multifocal electroretinograms (mfERGs) and psychophysical assessments of acuity and luminance visual field sensitivities were measured throughout the central retina. Comparisons of responses from equivalent retinal areas were accomplished by shifting normal templates to be centered at the locus of fixation for each patient. Losses of psychophysically measured visual function in patients with NCMD extend to areas adjacent to the locations of visible lesions. The multifocal ERG amplitude was reduced only within the area of visible lesion. Multifocal ERG implicit times were delayed throughout the entire central retinal area assessed. ERG timing is a sensitive assay of retinal function, and our results indicate that NCMD has a widespread effect at the level of the mid and outer retina. The findings also demonstrated that it is necessary to account for fixation locus and to ensure that equivalent retinal areas are compared when testing patients with macular disease who have eccentric fixation.
Clinical characteristics of occult macular dystrophy in family with mutation of RP1l1 gene.
Tsunoda, Kazushige; Usui, Tomoaki; Hatase, Tetsuhisa; Yamai, Satoshi; Fujinami, Kaoru; Hanazono, Gen; Shinoda, Kei; Ohde, Hisao; Akahori, Masakazu; Iwata, Takeshi; Miyake, Yozo
2012-06-01
To report the clinical characteristics of occult macular dystrophy (OMD) in members of one family with a mutation of the RP1L1 gene. Fourteen members with a p.Arg45Trp mutation in the RP1L1 gene were examined. The visual acuity, visual fields, fundus photographs, fluorescein angiograms, full-field electroretinograms, multifocal electroretinograms, and optical coherence tomographic images were examined. The clinical symptoms and signs and course of the disease were documented. All the members with the RP1L1 mutation except one woman had ocular symptoms and signs of OMD. The fundus was normal in all the patients during the entire follow-up period except in one patient with diabetic retinopathy. Optical coherence tomography detected the early morphologic abnormalities both in the photoreceptor inner/outer segment line and cone outer segment tip line. However, the multifocal electroretinograms were more reliable in detecting minimal macular dysfunction at an early stage of OMD. The abnormalities in the multifocal electroretinograms and optical coherence tomography observed in the OMD patients of different durations strongly support the contribution of RP1L1 mutation to the presence of this disease.
Bartha, Michael C; Allie, Paul; Kokot, Douglas; Roe, Cynthia Purvis
2015-01-01
Computer users continue to report eye and upper body discomfort even as workstation flexibility has improved. Research shows a relationship between character size, viewing distance, and reading performance. Few reports exist regarding text height viewed under normal office work conditions and eye discomfort. This paper reports self-selected computer display placement, text characteristics, and subjective comfort for older and younger computer workers under real-world conditions. Computer workers were provided with monitors and adjustable display support(s). In Study 1, older workers wearing progressive-addition lenses (PALs) were observed. In study 2, older workers wearing multifocal lenses and younger workers were observed. Workers wearing PALs experienced less eye and body discomfort with adjustable displays, and less eye and neck discomfort for text visual angles near or greater than ergonomic recommendations. Older workers wearing multifocal correction positioned displays much lower than younger workers. In general, computer users did not adjust character size to ensure that fovial images of text fell within the recommended range. Ergonomic display placement recommendations should be different for computer users wearing multifocal correction for presbyopia. Ergonomic training should emphasize adjusting text size for user comfort.
Intermediate addition multifocals provide safe stair ambulation with adequate 'short-term' reading.
Elliott, David B; Hotchkiss, John; Scally, Andrew J; Foster, Richard; Buckley, John G
2016-01-01
A recent randomised controlled trial indicated that providing long-term multifocal wearers with a pair of distance single-vision spectacles for use outside the home reduced falls risk in active older people. However, it also found that participants disliked continually switching between using two pairs of glasses and adherence to the intervention was poor. In this study we determined whether intermediate addition multifocals (which could be worn most of the time inside and outside the home and thus avoid continual switching) could provide similar gait safety on stairs to distance single vision spectacles whilst also providing adequate 'short-term' reading and near vision. Fourteen healthy long-term multifocal wearers completed stair ascent and descent trials over a 3-step staircase wearing intermediate and full addition bifocals and progression-addition lenses (PALs) and single-vision distance spectacles. Gait safety/caution was assessed using foot clearance measurements (toe on ascent, heel on descent) over the step edges and ascent and descent duration. Binocular near visual acuity, critical print size and reading speed were measured using Bailey-Lovie near charts and MNRead charts at 40 cm. Gait safety/caution measures were worse with full addition bifocals and PALs compared to intermediate bifocals and PALs. The intermediate PALs provided similar gait ascent/descent measures to those with distance single-vision spectacles. The intermediate addition PALs also provided good reading ability: Near word acuity and MNRead critical print size were better with the intermediate addition PALs than with the single-vision lenses (p < 0.0001), with a mean near visual acuity of 0.24 ± 0.13 logMAR (~N5.5) which is satisfactory for most near vision tasks when performed for a short period of time. The better ability to 'spot read' with the intermediate addition PALs compared to single-vision spectacles suggests that elderly individuals might better comply with the use of intermediate addition PALs outside the home. A lack of difference in gait parameters for the intermediate addition PALs compared to distance single-vision spectacles suggests they could be usefully used to help prevent falls in older well-adapted full addition PAL wearers. A randomised controlled trial to investigate the usefulness of intermediate multifocals in preventing falls seems warranted. © 2015 The Authors Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.
Zhu, Feng; Shen, Yi Bin; Li, Fu Qiang; Fang, Yun; Hu, Liang; Wu, Yi Jun
2016-01-01
Abstract The purpose of this study was to investigate the risk factors for central and lateral neck lymph node metastases in papillary thyroid carcinoma (PTC) and multifocal papillary thyroid carcinoma (MPTC), particularly when associated with Hashimoto thyroiditis (HT). A retrospective analysis of 763 consecutive patients who underwent total thyroidectomy with bilateral central neck dissection in the First Affiliated Hospital, College of Medicine, Zhejiang University between October 2011 and October 2014 was conducted. All patients had formal histological diagnoses of HT. Multivariable logistic regression analysis was performed to identify risk factors of neck lymph node metastases. Our study identified 277 PTC patients with HT and showed comparatively low rates of central lymph node metastases (CLNM) compared with the PTC patients without HT (37.2% versus 54.7%, P < 0.001). There were no statistically significant differences in lateral lymph node metastases (LLNM) (P = 0.656). Neck lymph node metastases were histologically proven in 127 (45.8%) patients with PTC with HT, including 103 CLNM and 24 LLNM. There were no significant differences in LLNM between the MPTC-associated HT and classic MPTC cases; however, a significantly reduced risk of CLNM was observed in the MPTC-associated HT compared with the MPTC cases (35.7% versus 72.4%, respectively, P < 0.001). In the multivariate analysis, HT was identified as an independent alleviating factor for CLNM in all PTC patients (odds ratio, 0.369; 95% confidence interval (CI), 0.261 to 0.521; P < 0.001) and in MPTC patients (odds ratio, 0.227; 95% CI, 0.126–0.406; P < 0.001). A cut-off of thyroid peroxidase antibody >140 IU/mL was established as the most sensitive and specific level for the prediction of MPTC based on receiver operating characteristic curve analyses. Thyroid peroxidase antibody, age, tumor size, and multifocality exhibited the ability to predict CLNM in PTC with HT patients with an area under the curve of 81.1% based on a multivariate model. Hashimoto thyroiditis was associated with increased prevalences of multifocality and capsular invasion. In contrast, HT was associated with a reduced risk of CLNM in PTC and MPTC patients, which indicated a potential protective effect. We found that the prognostic prediction model was applicable for predicting multifocality and CLNM in PTC patients with HT. PMID:26871795
Zhu, Feng; Shen, Yi Bin; Li, Fu Qiang; Fang, Yun; Hu, Liang; Wu, Yi Jun
2016-02-01
The purpose of this study was to investigate the risk factors for central and lateral neck lymph node metastases in papillary thyroid carcinoma (PTC) and multifocal papillary thyroid carcinoma (MPTC), particularly when associated with Hashimoto thyroiditis (HT).A retrospective analysis of 763 consecutive patients who underwent total thyroidectomy with bilateral central neck dissection in the First Affiliated Hospital, College of Medicine, Zhejiang University between October 2011 and October 2014 was conducted. All patients had formal histological diagnoses of HT. Multivariable logistic regression analysis was performed to identify risk factors of neck lymph node metastases.Our study identified 277 PTC patients with HT and showed comparatively low rates of central lymph node metastases (CLNM) compared with the PTC patients without HT (37.2% versus 54.7%, P < 0.001). There were no statistically significant differences in lateral lymph node metastases (LLNM) (P = 0.656). Neck lymph node metastases were histologically proven in 127 (45.8%) patients with PTC with HT, including 103 CLNM and 24 LLNM. There were no significant differences in LLNM between the MPTC-associated HT and classic MPTC cases; however, a significantly reduced risk of CLNM was observed in the MPTC-associated HT compared with the MPTC cases (35.7% versus 72.4%, respectively, P < 0.001). In the multivariate analysis, HT was identified as an independent alleviating factor for CLNM in all PTC patients (odds ratio, 0.369; 95% confidence interval (CI), 0.261 to 0.521; P < 0.001) and in MPTC patients (odds ratio, 0.227; 95% CI, 0.126-0.406; P < 0.001). A cut-off of thyroid peroxidase antibody >140 IU/mL was established as the most sensitive and specific level for the prediction of MPTC based on receiver operating characteristic curve analyses. Thyroid peroxidase antibody, age, tumor size, and multifocality exhibited the ability to predict CLNM in PTC with HT patients with an area under the curve of 81.1% based on a multivariate model.Hashimoto thyroiditis was associated with increased prevalences of multifocality and capsular invasion. In contrast, HT was associated with a reduced risk of CLNM in PTC and MPTC patients, which indicated a potential protective effect. We found that the prognostic prediction model was applicable for predicting multifocality and CLNM in PTC patients with HT.
On deformation of complex continuum immersed in a plane space
NASA Astrophysics Data System (ADS)
Kovalev, V. A.; Murashkin, E. V.; Radayev, Y. N.
2018-05-01
The present paper is devoted to mathematical modelling of complex continua deformations considered as immersed in an external plane space. The complex continuum is defined as a differential manifold supplied with metrics induced by the external space. A systematic derivation of strain tensors by notion of isometric immersion of the complex continuum into a plane space of a higher dimension is proposed. Problem of establishing complete systems of irreducible objective strain and extrastrain tensors for complex continuum immersed in an external plane space is resolved. The solution to the problem is obtained by methods of the field theory and the theory of rational algebraic invariants. Strain tensors of the complex continuum are derived as irreducible algebraic invariants of contravariant vectors of the external space emerging as functional arguments in the complex continuum action density. Present analysis is restricted to rational algebraic invariants. Completeness of the considered systems of rational algebraic invariants is established for micropolar elastic continua. Rational syzygies for non-quadratic invariants are discussed. Objective strain tensors (indifferent to frame rotations in the external plane space) for micropolar continuum are alternatively obtained by properly combining multipliers of polar decompositions of deformation and extra-deformation gradients. The latter is realized only for continua immersed in a plane space of the equal mathematical dimension.
Wang, Gordon; Smith, Stephen J.
2012-01-01
Photon diffraction limits the resolution of conventional light microscopy at the lateral focal plane to 0.61λ/NA (λ = wavelength of light, NA = numerical aperture of the objective) and at the axial plane to 1.4nλ/NA2 (n = refractive index of the imaging medium, 1.51 for oil immersion), which with visible wavelengths and a 1.4NA oil immersion objective is ∼220 nm and ∼600 nm in the lateral plane and axial plane respectively. This volumetric resolution is too large for the proper localization of protein clustering in subcellular structures. Here we combine the newly developed proteomic imaging technique, Array Tomography (AT), with its native 50–100 nm axial resolution achieved by physical sectioning of resin embedded tissue, and a 2D maximum likelihood deconvolution method, based on Bayes' rule, which significantly improves the resolution of protein puncta in the lateral plane to allow accurate and fast computational segmentation and analysis of labeled proteins. The physical sectioning of AT allows tissue specimens to be imaged at the physical optimum of modern high NA plan-apochormatic objectives. This translates to images that have little out of focus light, minimal aberrations and wave-front distortions. Thus, AT is able to provide images with truly invariant point spread functions (PSF), a property critical for accurate deconvolution. We show that AT with deconvolution increases the volumetric analytical fidelity of protein localization by significantly improving the modulation of high spatial frequencies up to and potentially beyond the spatial frequency cut-off of the objective. Moreover, we are able to achieve this improvement with no noticeable introduction of noise or artifacts and arrive at object segmentation and localization accuracies on par with image volumes captured using commercial implementations of super-resolution microscopes. PMID:22956902
Wang, Gordon; Smith, Stephen J
2012-01-01
Photon diffraction limits the resolution of conventional light microscopy at the lateral focal plane to 0.61λ/NA (λ = wavelength of light, NA = numerical aperture of the objective) and at the axial plane to 1.4nλ/NA(2) (n = refractive index of the imaging medium, 1.51 for oil immersion), which with visible wavelengths and a 1.4NA oil immersion objective is -220 nm and -600 nm in the lateral plane and axial plane respectively. This volumetric resolution is too large for the proper localization of protein clustering in subcellular structures. Here we combine the newly developed proteomic imaging technique, Array Tomography (AT), with its native 50-100 nm axial resolution achieved by physical sectioning of resin embedded tissue, and a 2D maximum likelihood deconvolution method, based on Bayes' rule, which significantly improves the resolution of protein puncta in the lateral plane to allow accurate and fast computational segmentation and analysis of labeled proteins. The physical sectioning of AT allows tissue specimens to be imaged at the physical optimum of modern high NA plan-apochormatic objectives. This translates to images that have little out of focus light, minimal aberrations and wave-front distortions. Thus, AT is able to provide images with truly invariant point spread functions (PSF), a property critical for accurate deconvolution. We show that AT with deconvolution increases the volumetric analytical fidelity of protein localization by significantly improving the modulation of high spatial frequencies up to and potentially beyond the spatial frequency cut-off of the objective. Moreover, we are able to achieve this improvement with no noticeable introduction of noise or artifacts and arrive at object segmentation and localization accuracies on par with image volumes captured using commercial implementations of super-resolution microscopes.
Psychiatric disorders in candidates for surgery for epilepsy.
Manchanda, R; Schaefer, B; McLachlan, R S; Blume, W T; Wiebe, S; Girvin, J P; Parrent, A; Derry, P A
1996-01-01
OBJECTIVE--To provide a descriptive analysis of the prevalence and pattern of psychiatric morbidity among 300 consecutive epileptic patients refractive to treatment and admitted during a six year period for evaluation of their candidature for surgery. METHODS--Patients underwent detailed observation of their seizure and standardised psychiatric assessment. Patients were considered to be refractory to treatment if they continued to manifest seizures with an average frequency of at least once every month even with polytherapy using up to three different anti-convulsants for a period of at least two years. Of the 300 patients, 231 had a temporal lobe focus, 43 had a non-temporal lobe focus, and 26 patients had a generalised and multifocal seizure onset. RESULTS AND CONCLUSIONS--With the DSM-III-R criteria 142 (47.3%) patients emerged as psychiatric cases. A principal axis I diagnosis was made in 88 (29.3%), and an axis II diagnosis (personality disorder) in another 54 (18.0%) patients. The most common axis I diagnosis was anxiety disorders (10.7%). A schizophrenia-like psychosis was seen in 13 (4.3%). Most patients with personality disorders showed dependent and avoidant personality traits. There was a significantly higher psychotic subscore on the present state examination in the temporal than with the non-temporal group of patients. These findings were not significant when compared with patients with a generalised and multifocal seizure disorder. There were no significant findings between the different seizure focus groups on the neurotic subscores. The findings with regard to laterality of seizure focus and the neurotic or psychotic subscores were not significant. PMID:8676167
The Classical Laplace Plane and Its use as a Stable Disposal Orbit for GEO
NASA Astrophysics Data System (ADS)
Rosengren, A.; Scheeres, D.; McMahon, J.
2013-09-01
The geosynchronous Earth orbit (GEO) is the most susceptible region to space debris because there is no natural cleansing mechanism, such as atmospheric drag. Placing satellites in super-synchronous disposal orbits at the ends of their operational lifetimes has been recommended and practiced as one possible means of protecting this environment. The discovery of the high area-to-mass ratio (HAMR) debris population in near geosynchronous orbit (ca. 2004) raises concern for the long-term sustainability of this unique resource. It is currently believed that HAMR objects are sheets of multilayer insulation detaching from satellites in GEO disposal orbits due to surface degradation and material deterioration. The low energy release of HAMR objects from aging satellites abandoned in disposal orbits is not directly addressed in the national policies that established the graveyard. The current disposal regions cannot account for the large solar radiation pressure (SRP) perturbations of HAMR objects, implying that these storage orbits are not well suited as a graveyard. The orbital dynamics of uncontrolled GEO satellites is governed by the oblateness of the Earth and luni-solar gravitational interactions. By itself, Earth's oblateness causes the pole of the orbital plane to precess around Earth's rotation pole. Lunisolar perturbations will have a similar effect, but the precession will now take place about the orbit poles of the Moon and the Sun, respectively. The classical Laplace plane is the mean reference plane about whose axis the satellite's orbit precesses. On the Laplace place, the secular orbital evolution driven by the combined effects of these perturbations is zero, so that the orbits are frozen. The Laplace plane at GEO lies between the plane of the Earth's equator and that of the ecliptic, passing through their intersection, and has an inclination of about 7.5 degrees relative to Earth's equator. The uncontrolled GEO satellites precess at a constant inclination about the pole of this plane with a period of nearly 53 years. The significance of the Laplace plane for use as a GEO disposal orbit is that the orbits of satellites placed in this stable equilibrium will be fixed on average, and that any orbit at small inclination to it regresses around this plane at nearly constant inclination and rate. This stable graveyard can be specified for a range of semi-major axes above GEO, and satellites placed in this region will have significantly reduced relative encounter velocities, compared to the current graveyard. Thus, if collisions were to occur between satellites in the stable graveyard, they would occur at very low velocities, thereby damping out the relative motion of these objects. We explore the use of the classical Laplace plane as a long-term GEO disposal orbit. We show that HAMR objects released from satellites located in this stable equilibrium will be trapped in inclination and node phase space, and will not likely cross the GEO protected region. This is followed by a discussion of the robustness of these solutions to more realistic SRP models and an investigation of the economic viability of our proposed GEO graveyard.
Investigating the free-body diagram of a stationary object on an inclined plane using Apple Watch
NASA Astrophysics Data System (ADS)
Dilek, Ufuk; Çalışkan, Serap
2017-11-01
In this study, we present an activity in which the free-body diagram of a real stationary object on an inclined plane can be examined interactively. We use an Apple Watch and a few other materials that can be accessed easily. Instead of an Apple Watch, a mobile phone or a tablet could also be used. This activity may be employed to introduce the fundamental concepts associated with free-body diagrams in classroom settings, or adapted to physics labs.
Analysis of in-plane signal-to-noise ratio in computed tomography
NASA Astrophysics Data System (ADS)
Hara, Takanori; Ichikawa, Katsuhiro; Sanada, Shigeru; Ida, Yoshihiro
2008-03-01
The purposes of this study are to analyze signal-to-noise ratio (SNR) changes for in-plane (axial plane) position and in-plane direction in X-ray computed tomography (CT) system and to verify those visual effects by using simulated small low-contrast disc objects. Three-models of multi detector-row CT were employed. Modulation transfer function (MTF) was obtained using a thin metal wire. Noise power spectrum (NPSs) was obtained using a cylindrical water phantom. The measurement positions were set to center and off-centered positions of 64mm, 128mm and 192mm. One-dimensional MTFs and NPSs for the x- and y-direction were calculated by means of a numerical slit scanning method. SNRs were then calculated from MTFs and NPSs. The simulated low-contrast disc objects with diameter of 2 to 10mm and contrast to background of 3.0%, 4.5% and 6.0% were superimposed on the water phantom images. Respective simulated objects in the images are then visually evaluated in degree of their recognition, and then the validity of the resultant SNRs are examined. Resultant in-plane SNRs differed between the center and peripheries and indicated a trend that the SNR values increase in accordance with distance from the center. The increasing degree differed between x- and y-direction, and also changed by the CT systems. These results suggested that the peripheries region has higher low-contrast detectability than the center. The properties derived in this study indicated that the depiction abilities at various in-plane positions are not uniform in clinical CT images, and detectability of the low contrast lesion may be influenced.
NASA Astrophysics Data System (ADS)
Lv, Zeqian; Xu, Xiaohai; Yan, Tianhao; Cai, Yulong; Su, Yong; Zhang, Qingchuan
2018-01-01
In the measurement of plate specimens, traditional two-dimensional (2D) digital image correlation (DIC) is challenged by two aspects: (1) the slant optical axis (misalignment of the optical camera axis and the object surface) and (2) out-of-plane motions (including translations and rotations) of the specimens. There are measurement errors in the results measured by 2D DIC, especially when the out-of-plane motions are big enough. To solve this problem, a novel compensation method has been proposed to correct the unsatisfactory results. The proposed compensation method consists of three main parts: 1) a pre-calibration step is used to determine the intrinsic parameters and lens distortions; 2) a compensation panel (a rigid panel with several markers located at known positions) is mounted to the specimen to track the specimen's motion so that the relative coordinate transformation between the compensation panel and the 2D DIC setup can be calculated using the coordinate transform algorithm; 3) three-dimensional world coordinates of measuring points on the specimen can be reconstructed via the coordinate transform algorithm and used to calculate deformations. Simulations have been carried out to validate the proposed compensation method. Results come out that when the extensometer length is 400 pixels, the strain accuracy reaches 10 με no matter out-of-plane translations (less than 1/200 of the object distance) nor out-of-plane rotations (rotation angle less than 5°) occur. The proposed compensation method leads to good results even when the out-of-plane translation reaches several percents of the object distance or the out-of-plane rotation angle reaches tens of degrees. The proposed compensation method has been applied in tensile experiments to obtain high-accuracy results as well.
Overcoming Presbyopia by Manipulating the Eyes' Optics
NASA Astrophysics Data System (ADS)
Zheleznyak, Leonard A.
Presbyopia, the age-related loss of accommodation, is a visual condition affecting all adults over the age of 45 years. In presbyopia, individuals lose the ability to focus on nearby objects, due to a lifelong growth and stiffening of the eye's crystalline lens. This leads to poor near visual performance and affects patients' quality of life. The objective of this thesis is aimed towards the correction of presbyopia and can be divided into four aims. First, we examined the characteristics and limitations of currently available strategies for the correction of presbyopia. A natural-view wavefront sensor was used to objectively measure the accommodative ability of patients implanted with an accommodative intraocular lens (IOL). Although these patients had little accommodative ability based on changes in power, pupil miosis and higher order aberrations led to an improvement in through-focus retinal image quality in some cases. To quantify the through-focus retinal image quality of accommodative and multifocal IOLs directly, an adaptive optics (AO) IOL metrology system was developed. Using this system, the impact of corneal aberrations in regard to presbyopia-correcting IOLs was assessed, providing an objective measure of through-focus retinal image quality and practical guidelines for patient selection. To improve upon existing multifocal designs, we investigated retinal image quality metrics for the prediction of through-focus visual performance. The preferred metric was based on the fidelity of an image convolved with an aberrated point spread function. Using this metric, we investigated the potential of higher order aberrations and pupil amplitude apodization to increase the depth of focus of the presbyopic eye. Thirdly, we investigated modified monovision, a novel binocular approach to presbyopia correction using a binocular AO vision simulator. In modified monovision, different magnitudes of defocus and spherical aberration are introduced to each eye, thereby taking advantage of the binocular visual system. Several experiments using the binocular AO vision simulator found modified monovision led to significant improvements in through-focus visual performance, binocular summation and stereoacuity, as compared to traditional monovision. Finally, we addressed neural factors, affecting visual performance in modified monovision, such as ocular dominance and neural plasticity. We found that pairing modified monovision with a vision training regimen may further improve visual performance beyond the limits set by optics via neural plasticity. This opens the door to an exciting new avenue of vision correction to accompany optical interventions. The research presented in this thesis offers important guidelines for the clinical and scientific communities. Furthermore, the techniques described herein may be applied to other fields of ophthalmology, such as childhood myopia progression.
Effect of planar cuts' orientation on the perceived surface layout and object's shape.
Bocheva, Nadejda
2009-07-01
The effect of the orientation of the cutting planes producing planar curves over the surface of an object on its perceived pose and shape was investigated for line drawings representing three-dimensional objects. The results suggest that the orientational flow produced by the surface curves introduces an apparent object rotation in depth and in the image plane and changes in its perceived elongation. The apparent location of the nearest points is determined by the points of maximal view-dependent unsigned curvature of the surface curves. The data are discussed in relation to the interaction of the shape-from-silhouette system and shape-from-contour system and its effect on the interpretation of the surface contours with respect to the surface geometry.
NASA Technical Reports Server (NTRS)
Cambridge, Vivien J.; Magee, Ronald G.
1993-01-01
The method of silhouettes proceeds from the premise that the 3D location and shape of an arbitrary object can be approximated via the cross section of a series of conical volumes whose focal points are arranged at sites surrounding the object; the projection of each conical volume onto a picture plane at each focal point is identical to a projection of the outline of the object onto that picture plane. Attention is presently given to the use of the silhouettes method for gas plume dispersion monitoring through the 3D reconstruction of plumes from imagery acquired at strategically located stations in the plumes' path.
Sandwich holospeckle interferometry for three-dimensional displacement determination
NASA Astrophysics Data System (ADS)
Wu, X. P.; Chiang, F. P.
1986-06-01
A sandwich holospecklegram (SH) technique with flexible sensitivity is presented for performing both in-plane and out-of-plane displacement measurements of objects. An object beam from a laser is directed onto a part-mirror onto which the object image is also directed and produces interference in the beam. The beam is redirected to fall, with a reference beam, onto photographic and speckle plates with their emulsion sides against one another, ergo, the sandwich. Reconstruction methods are delineated and illustrated with an SH of a crack in an aluminum alloy plate undergoing a three-point bending test. The crack is noted to occur in a region only 2 mm across.
Astronomical telescope with holographic primary objective
NASA Astrophysics Data System (ADS)
Ditto, Thomas D.; Friedman, Jeffrey F.; Content, David A.
2011-09-01
A dual dispersion telescope with a plane grating primary objective was previously disclosed that can overcome intrinsic chromatic aberration of dispersive optics while allowing for unprecedented features such as million object spectroscopy, extraordinary étendue, flat primary objective with a relaxed figure tolerance, gossamer membrane substrate stowable as an unsegmented roll inside a delivery vehicle, and extensibility past 100 meter aperture at optical wavelengths. The novel design meets many criteria for space deployment. Other embodiments are suitable for airborne platforms as well as terrestrial and lunar sites. One problem with this novel telescope is that the grazing exodus configuration necessary to achieve a large aperture is traded for throughput efficiency. Now we show how the hologram of a point source used in place of the primary objective plane grating can improve efficiency by lowering the diffraction angle below grazing exodus. An intermediate refractive element is used to compensate for wavelength dependent focal lengths of the holographic primary objective.
Range camera on conveyor belts: estimating size distribution and systematic errors due to occlusion
NASA Astrophysics Data System (ADS)
Blomquist, Mats; Wernersson, Ake V.
1999-11-01
When range cameras are used for analyzing irregular material on a conveyor belt there will be complications like missing segments caused by occlusion. Also, a number of range discontinuities will be present. In a frame work towards stochastic geometry, conditions are found for the cases when range discontinuities take place. The test objects in this paper are pellets for the steel industry. An illuminating laser plane will give range discontinuities at the edges of each individual object. These discontinuities are used to detect and measure the chord created by the intersection of the laser plane and the object. From the measured chords we derive the average diameter and its variance. An improved method is to use a pair of parallel illuminating light planes to extract two chords. The estimation error for this method is not larger than the natural shape fluctuations (the difference in diameter) for the pellets. The laser- camera optronics is sensitive enough both for material on a conveyor belt and free falling material leaving the conveyor.
NASA Technical Reports Server (NTRS)
Mielke, Roland; Dcunha, Ivan; Alvertos, Nicolas
1994-01-01
In the final phase of the proposed research a complete top to down three dimensional object recognition scheme has been proposed. The various three dimensional objects included spheres, cones, cylinders, ellipsoids, paraboloids, and hyperboloids. Utilizing a newly developed blob determination technique, a given range scene with several non-cluttered quadric surfaces is segmented. Next, using the earlier (phase 1) developed alignment scheme, each of the segmented objects are then aligned in a desired coordinate system. For each of the quadric surfaces based upon their intersections with certain pre-determined planes, a set of distinct features (curves) are obtained. A database with entities such as the equations of the planes and angular bounds of these planes has been created for each of the quadric surfaces. Real range data of spheres, cones, cylinders, and parallelpipeds have been utilized for the recognition process. The developed algorithm gave excellent results for the real data as well as for several sets of simulated range data.
An accelerated hologram calculation using the wavefront recording plane method and wavelet transform
NASA Astrophysics Data System (ADS)
Arai, Daisuke; Shimobaba, Tomoyoshi; Nishitsuji, Takashi; Kakue, Takashi; Masuda, Nobuyuki; Ito, Tomoyoshi
2017-06-01
Fast hologram calculation methods are critical in real-time holography applications such as three-dimensional (3D) displays. We recently proposed a wavelet transform-based hologram calculation called WASABI. Even though WASABI can decrease the calculation time of a hologram from a point cloud, it increases the calculation time with increasing propagation distance. We also proposed a wavefront recoding plane (WRP) method. This is a two-step fast hologram calculation in which the first step calculates the superposition of light waves emitted from a point cloud in a virtual plane, and the second step performs a diffraction calculation from the virtual plane to the hologram plane. A drawback of the WRP method is in the first step when the point cloud has a large number of object points and/or a long distribution in the depth direction. In this paper, we propose a method combining WASABI and the WRP method in which the drawbacks of each can be complementarily solved. Using a consumer CPU, the proposed method succeeded in performing a hologram calculation with 2048 × 2048 pixels from a 3D object with one million points in approximately 0.4 s.
NASA Astrophysics Data System (ADS)
Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu
2016-08-01
Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.
Acute disseminated encephalomyelitis: a case report of effective early immunotherapy
NASA Astrophysics Data System (ADS)
Ritarwan, K.; Ramayani, O. R.; Eyanoer, P.
2018-03-01
Acute disseminated encephalomyelitis (ADEM) is a monophasic acute non-vasculitic inflammatory demyelinating disorder of the central nervous system characterized by diffuse neurologic signs and symptoms coupled with evidence of multifocal lesions of demyelination on neuroimaging. Despite the long-standing recognition of ADEM as a specific entity, no consensus definition of ADEM had been reached until recently. Historically, different definitions of ADEM have been in published cases of pediatric and adult patients, which varied as to whether events required (1) monofocal or multifocal clinical features, (2) a change in mental status, and (3) a documentation of previous infection or immunization. The treatment has been given to the patient such as supportive therapy and high dose corticosteroids.
Outbreak of pasteurellosis in captive Bolivian squirrel monkeys (Saimiri boliviensis)
YOSHINO, Mizuki; SASAKI, Jun; KURAMOCHI, Konomi; IKEZAWA, Mitsutaka; MUKAIZAWA, Natsuko; GORYO, Masanobu
2017-01-01
In September 2012, five Bolivian squirrel monkeys housed in a zoological park died within sequential several days without obvious clinical signs. In a necrospy, one monkey presented swelling of the kidney with multifocal white nodules in the parenchyma, and other two had pulmonary congestion. Histopathologically, multifocal bacterial colonies of gram-negative coccobacillus were found in the sinusoid of the liver in all monkeys examined (Nos.1−4). Additionally, purulent pyelonephritis, pneumonia and disseminated small bacterial colonies in blood vessels were observed. Immunohistochemically, the bacterial colonies from two monkeys were positive for P. multocida capsular serotype D. Based on these findings, these monkeys were diagnosed as septicemia caused by acute P. multocida infection. PMID:28190821
Iwata, Kei; Kasuya, Kazufumi; Takayama, Kou; Nakahara, Yusuke; Kobayashi, Yoshifumi; Kato, Asako; Senba, Hironobu; Yanagisawa, Masae; Shibahara, Tomoyuki
2018-06-11
A 2-year-female arctic fox (Vulpes lagopus) developed anorexia, dehydration, and emaciation during the quarantine period for importation from Norway, and died 17 days later. At necropsy, a fistula was observed on the left gluteal region, and the left eye, left brain, and kidneys were discolored. Histologically, severe diffuse suppurative meningoencephalitis and renal abscesses were detected. Numerous Gram-positive cocci were detected in these lesions. Multidrug-susceptible Staphylococcus pseudintermedius were isolated from the lesions. These results suggest that S. pseudintermedius can cause severe multifocal suppurative meningoencephalitis and nephritis in foxes. This is the first report of multidrug-susceptible S. pseudintermedius meningoencephalitis and nephritis in a fox.
Outbreak of pasteurellosis in captive Bolivian squirrel monkeys (Saimiri boliviensis).
Yoshino, Mizuki; Sasaki, Jun; Kuramochi, Konomi; Ikezawa, Mitsutaka; Mukaizawa, Natsuko; Goryo, Masanobu
2017-03-23
In September 2012, five Bolivian squirrel monkeys housed in a zoological park died within sequential several days without obvious clinical signs. In a necrospy, one monkey presented swelling of the kidney with multifocal white nodules in the parenchyma, and other two had pulmonary congestion. Histopathologically, multifocal bacterial colonies of gram-negative coccobacillus were found in the sinusoid of the liver in all monkeys examined (Nos.1-4). Additionally, purulent pyelonephritis, pneumonia and disseminated small bacterial colonies in blood vessels were observed. Immunohistochemically, the bacterial colonies from two monkeys were positive for P. multocida capsular serotype D. Based on these findings, these monkeys were diagnosed as septicemia caused by acute P. multocida infection.
Extremely Painful Multifocal Acquired Predominant Axonal Sensorimotor Neuropathy of the Upper Limb.
Lieba-Samal, Doris; van Eijk, Jeroen J J; van Rosmalen, Marieke H J; van Balken, Irene M F; Verrips, Aad; Mostert, Jop; Pillen, Sigrid; van Alfen, Nens
2018-06-01
The differential diagnosis of upper extremity mononeuritis multiplex includes neuralgic amyotrophy, vasculitic neuropathy, and Lewis-Sumner syndrome. We describe 3 patients initially suspected of neuralgic amyotrophy, who had an extremely painful, protracted, progressive disease course, not fitting one of these established diagnoses. Nerve ultrasonography showed focal caliber changes of the roots, plexus, and limb nerves. Electromyography showed predominant multifocal axonopathy. Ongoing autoimmune neuropathy was suspected. Steroid treatment provided temporary relief, and intravenous immunoglobulin A sustained pain decrease and functional improvement. These patients appear to have extremely painful axonal inflammatory neuropathy, with a good response to immune-modulating treatment. © 2017 by the American Institute of Ultrasound in Medicine.
Multifocal Epithelial Hyperplasia of Oral Cavity Expressing HPV 16 Gene: A Rare Entity
Prabhat, M. P. V.; Raja Lakshmi, Chintamaneni; Sai Madhavi, N.; Bhavana, Sujana Mulk; Sarat, Gummadapu; Ramamohan, Kodali
2013-01-01
Focal epithelial hyperplasia is a rare contagious disease caused by human papilloma virus. Usually HPV involves either cutaneous or mucosal surfaces, whereas concomitant mucocutaneous involvement is extremely rare. We report such a unique case of multifocal epithelial hyperplasia involving multiple sites of oral cavity along with skin lesions in a 65-year-old female. We also discuss the probable multifactorial etiology and variable clinical presentations of the lesions, including evidence of HPV 16 expression, as detected by polymerase chain reaction. The present report illustrates the need for careful examination and prompt diagnosis of the disease, as it might be associated with high risk genotypes such as HPV 16 and 18. PMID:24455323
Phase-Shifting Zernike Interferometer Wavefront Sensor
NASA Technical Reports Server (NTRS)
Wallace, J. Kent; Rao, Shanti; Jensen-Clemb, Rebecca M.; Serabyn, Gene
2011-01-01
The canonical Zernike phase-contrast technique1,2,3,4 transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/D) of the PSF which is intermediate between the input and output planes. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective. Second, the phase shift in the central core of the PSF is dynamic and or arbitrary size. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument
Phase-Shifting Zernike Interferometer Wavefront Sensor
NASA Technical Reports Server (NTRS)
Wallace, J. Kent; Rao, Shanti; Jensen-Clem, Rebecca M.
2011-01-01
The canonical Zernike phase-contrast technique transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/diameter) of the PSF which is intermediate between the input and output plane. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective, and second the phase shift in the central core of the PSF is dynamic and can be made arbitrarily large. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument.
Lewandowski, Allan A.; Yampolskiy, Vladislav; Alekseev, Valerie; Son, Valentin
2001-01-01
According to the proposed invention, this technical result is achieved so that many-facet concentrator of a solar setup for exposure of objects, placed in a target plane, to the action of solar radiation containing a supporting frame and facets differing by that the facets of the concentrator are chosen with spherical focusing reflective surfaces of equal focal lengths and with selective coatings reflecting a desired spectral fraction of solar radiation, and are arranged on the supporting frame symmetrically with respect to the common axis of the concentrator, their optical axes being directed to the single point on the optical axis of the concentrator located before the nominal focus point of the concentrator and determining the position of arranging the target plane.
The Cutplane - A tool for interactive solid modeling
NASA Technical Reports Server (NTRS)
Edwards, Laurence; Kessler, William; Leifer, Larry
1988-01-01
A geometric modeling system which incorporates a new concept for intuitively and unambiguously specifying and manipulating points or features in three dimensional space is presented. The central concept, the Cutplane, consists of a plane that moves through space under control of a mouse or similar input device. The intersection of the plane and any object is highlighted, and only this highlighted section can be selected for manipulation. Selection is accomplished with a crosshair that is constrained to remain within the plane, so that the relationship between the crosshair and the feature of interest is immediately evident. Although the idea of a section view is not new, previously it has been used as a way to reveal hidden structure, not as a means of manipulating objects or indicating spatial position, as is proposed here.
Single-exposure color digital holography
NASA Astrophysics Data System (ADS)
Feng, Shaotong; Wang, Yanhui; Zhu, Zhuqing; Nie, Shouping
2010-11-01
In this paper, we report a method for color image reconstruction by recording only one single multi-wavelength hologram. In the recording process, three lasers of different wavelengths emitting in the red, green and blue regions are used for illuminating on the object and the object diffraction fields will arrive at the hologram plane simultaneously. Three reference beams with different spatial angles will interfere with the corresponding object diffraction fields on the hologram plane, respectively. Finally, a series of sub-holograms incoherently overlapped on the CCD to be recorded as a multi-wavelength hologram. Angular division multiplexing is employed to reference beams so that the spatial spectra of the multiple recordings will be separated in the Fourier plane. In the reconstruction process, the multi-wavelength hologram will be Fourier transformed into its Fourier plane, where the spatial spectra of different wavelengths are separated and can be easily extracted by employing frequency filtering. The extracted spectra are used to reconstruct the corresponding monochromatic complex amplitudes, which will be synthesized to reconstruct the color image. For singleexposure recording technique, it is convenient for applications on the real-time image processing fields. However, the quality of the reconstructed images is affected by speckle noise. How to improve the quality of the images needs for further research.
Gaze behavior and the perception of egocentric distance
Gajewski, Daniel A.; Wallin, Courtney P.; Philbeck, John W.
2014-01-01
The ground plane is thought to be an important reference for localizing objects, particularly when angular declination is informative, as it is for objects seen resting at floor level. A potential role for eye movements has been implicated by the idea that information about the nearby ground is required to localize objects more distant, and by the fact that the time course for the extraction of distance extends beyond the duration of a typical eye fixation. To test this potential role, eye movements were monitored when participants previewed targets. Distance estimates were provided by walking without vision to the remembered target location (blind walking) or by verbal report. We found that a strategy of holding the gaze steady on the object was as frequent as one where the region between the observer and object was fixated. There was no performance advantage associated with making eye movements in an observational study (Experiment 1) or when an eye-movement strategy was manipulated experimentally (Experiment 2). Observers were extracting useful information covertly, however. In Experiments 3 through 5, obscuring the nearby ground plane had a modest impact on performance; obscuring the walls and ceiling was more detrimental. The results suggest that these alternate surfaces provide useful information when judging the distance to objects within indoor environments. Critically, they constrain the role for the nearby ground plane in theories of egocentric distance perception. PMID:24453346
Multifocal colitis associated with an epidemic of chronic diarrhea.
Janda, R C; Conklin, J L; Mitros, F A; Parsonnet, J
1991-02-01
An outbreak of a chronic diarrheal syndrome was detected between May and August 1987 in rural Henderson County, Illinois. Seventy-two individuals were affected. Epidemiological studies performed by the Center for Disease Control implicated the water of a local restaurant as the source of the outbreak. Five patients underwent a comprehensive evaluation. Their mean age was 51 years, and they had a mean of 12 watery stools daily (range, 6-40). Detailed microbiological evaluations failed to identify a pathological organism. Stool studies showed a mean stool weight of 392 g/24 h with a normal fat content. Results of all biochemical studies of serum were normal. Chemical analysis of stool water suggested a secretory diarrhea. Colonoscopy revealed patchy erythema, and light microscopic examination of colonic biopsy specimens revealed multifocal areas of acute inflammation in the superficial mucosa in 4 of 5 patients. Electron microscopy of the affected areas revealed no viral particles. After 2 years, all of our patients continued to experience chronic diarrhea. One patient agreed to a follow-up colonoscopy; histological abnormalities of the colonic mucosa persisted after 2 years. We speculate that an infectious process arising from a contaminated water system induced a chronic, secretory diarrhea characterized by multifocal colitis. This histological abnormality may serve as a marker of an infectious, chronic diarrhea.
[Indication guidelines for medical rehabilitation in the context of disease management programmes].
Raspe, Heiner
2005-02-01
In current and upcoming disease management programmes in Germany, the provision of medical services is strongly oriented on ICD diagnoses and on services traditionally provided by the statutory health insurance. Multidisciplinary services, such as medical rehabilitation, mostly covered by other payers (e.g. pension funds) are not taken into account. On the other hand, many chronically-ill patients have complex and multifocal health complaints that are best addressed by multidisciplinary interventions. Considering this inherent deficit, in 2002 the German Society of Rehabilitation Sciences has initiated the research project "Indication Guidelines" aimed at developing indication criteria for rehabilitation in the context of disease management programmes. The concept presented in this paper relies on three basic requirements: 1. Impaired participation (according to ICF) caused by multifocal deficits leads to the definition of goals for rehabilitation, taking into account clinical and legal aspects as well as the patients preferences. 2. Multifocal health problems are best addressed by a multidisciplinary rehabilitation programme as it is currently provided by the German pension funds. 3. Scientific evidence has to demonstrate that these programmes are very likely to be effective (positive rehabilitation prognosis, evidence-based rehabilitation). Further requirements include adequate instruction of patients, as well as intensive and prolonged after-care. Both could be very well integrated into comprehensive disease management programmes.
Multifocal visual evoked potential and automated perimetry abnormalities in strabismic amblyopes.
Greenstein, Vivienne C; Eggers, Howard M; Hood, Donald C
2008-02-01
To compare visual field abnormalities obtained with standard automated perimetry (SAP) to those obtained with the multifocal visual evoked potential (mfVEP) technique in strabismic amblyopes. Humphrey 24-2 visual fields (HVF) and mfVEPs were obtained from each eye of 12 strabismic amblyopes. For the mfVEP, amplitudes and latencies were analyzed and probability plots were derived. Multifocal VEP and HVF hemifields were abnormal if they had clusters of two or more contiguous points at p < 0.01, or three or more contiguous points at p < 0.05 with at least one at p < 0.01. An eye was abnormal if it had an abnormal hemifield. On SAP, amblyopic eyes had significantly higher foveal thresholds (p = 0.003) and lower mean deviation values (p = 0.005) than fellow eyes. For the mfVEP, 11 amblyopic and 6 fellow eyes were abnormal. Of the 11 amblyopic eyes, 6 were abnormal on SAP. The deficits extended from the center to mid periphery. Monocular mfVEP latencies were significantly decreased for amblyopic eyes compared with control eyes (p < 0.0002). Both techniques revealed deficits in visual function across the visual field in strabismic amblyopes, but the mfVEP revealed deficits in fellow eyes and in more amblyopic eyes. In addition, mfVEP response latencies for amblyopic eyes were shorter than normal.
Novel interactive virtual showcase based on 3D multitouch technology
NASA Astrophysics Data System (ADS)
Yang, Tao; Liu, Yue; Lu, You; Wang, Yongtian
2009-11-01
A new interactive virtual showcase is proposed in this paper. With the help of virtual reality technology, the user of the proposed system can watch the virtual objects floating in the air from all four sides and interact with the virtual objects by touching the four surfaces of the virtual showcase. Unlike traditional multitouch system, this system cannot only realize multi-touch on a plane to implement 2D translation, 2D scaling, and 2D rotation of the objects; it can also realize the 3D interaction of the virtual objects by recognizing and analyzing the multi-touch that can be simultaneously captured from the four planes. Experimental results show the potential of the proposed system to be applied in the exhibition of historical relics and other precious goods.
Smith, Richard W.
1979-01-01
An acoustic imaging system for displaying an object viewed by a moving array of transducers as the array is pivoted about a fixed point within a given plane. A plurality of transducers are fixedly positioned and equally spaced within a laterally extending array and operatively directed to transmit and receive acoustic signals along substantially parallel transmission paths. The transducers are sequentially activated along the array to transmit and receive acoustic signals according to a preestablished sequence. Means are provided for generating output voltages for each reception of an acoustic signal, corresponding to the coordinate position of the object viewed as the array is pivoted. Receptions from each of the transducers are presented on the same display at coordinates corresponding to the actual position of the object viewed to form a plane view of the object scanned.
Measurement of vibration using phase only correlation technique
NASA Astrophysics Data System (ADS)
Balachandar, S.; Vipin, K.
2017-08-01
A novel method for the measurement of vibration is proposed and demonstrated. The proposed experiment is based on laser triangulation: consists of line laser, object under test and a high speed camera remotely controlled by a software. Experiment involves launching a line-laser probe beam perpendicular to the axis of the vibrating object. The reflected probe beam is recorded by a high speed camera. The dynamic position of the line laser in camera plane is governed by the magnitude and frequency of the vibrating test-object. Using phase correlation technique the maximum distance travelled by the probe beam in CCD plane is measured in terms of pixels using MATLAB. An actual displacement of the object in mm is measured by calibration. Using displacement data with time, other vibration associated quantities such as acceleration, velocity and frequency are evaluated. The preliminary result of the proposed method is reported for acceleration from 1g to 3g, and from frequency 6Hz to 26Hz. The results are closely matching with its theoretical values. The advantage of the proposed method is that it is a non-destructive method and using phase correlation algorithm subpixel displacement in CCD plane can be measured with high accuracy.
Bartlett, Eric S; Walters, Thomas D; Yu, Eugene
2013-01-01
Objective. We evaluate if axial-based lymph node size criteria can be applied to coronal and sagittal planes. Methods. Fifty pretreatment computed tomographic (CT) neck exams were evaluated in patients with head and neck squamous cell carcinoma (SCCa) and neck lymphadenopathy. Axial-based size criteria were applied to all 3 imaging planes, measured, and classified as "enlarged" if equal to or exceeding size criteria. Results. 222 lymph nodes were "enlarged" in one imaging plane; however, 53.2% (118/222) of these were "enlarged" in all 3 planes. Classification concordance between axial versus coronal/sagittal planes was poor (kappa = -0.09 and -0.07, resp., P < 0.05). The McNemar test showed systematic misclassification when comparing axial versus coronal (P < 0.001) and axial versus sagittal (P < 0.001) planes. Conclusion. Classification of "enlarged" lymph nodes differs between axial versus coronal/sagittal imaging planes when axial-based nodal size criteria are applied independently to all three imaging planes, and exclusively used without other morphologic nodal data.
Bartlett, Eric S.; Walters, Thomas D.; Yu, Eugene
2013-01-01
Objective. We evaluate if axial-based lymph node size criteria can be applied to coronal and sagittal planes. Methods. Fifty pretreatment computed tomographic (CT) neck exams were evaluated in patients with head and neck squamous cell carcinoma (SCCa) and neck lymphadenopathy. Axial-based size criteria were applied to all 3 imaging planes, measured, and classified as “enlarged” if equal to or exceeding size criteria. Results. 222 lymph nodes were “enlarged” in one imaging plane; however, 53.2% (118/222) of these were “enlarged” in all 3 planes. Classification concordance between axial versus coronal/sagittal planes was poor (kappa = −0.09 and −0.07, resp., P < 0.05). The McNemar test showed systematic misclassification when comparing axial versus coronal (P < 0.001) and axial versus sagittal (P < 0.001) planes. Conclusion. Classification of “enlarged” lymph nodes differs between axial versus coronal/sagittal imaging planes when axial-based nodal size criteria are applied independently to all three imaging planes, and exclusively used without other morphologic nodal data. PMID:23984099
Mononeuritis multiplex; Mononeuropathy multiplex; Multifocal neuropathy; Peripheral neuropathy - mononeuritis multiplex ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...
Pycha, A; Mian, C; Hofbauer, J; Brössner, C; Haitel, A; Wiener, H; Marberger, M
1999-01-01
Multifocality of transitional cell carcinoma (TCC) has been attributed to seeding of exfoliated tumor cells or to a general sensitivity of the entire urothelium to carcinogenic stimuli. By contrast, TCC has been shown to evolve as a consequence of genetic defects and chromosomal instability. We analyzed chromosomal patterns, total DNA content, and p53 and Ki67 expression in malignant and normal transitional cells to evaluate their relationship to the development of multifocal TCC. Included in the study were 47 patients, 16 women and 31 men, with a mean age of 70.04 years (range 37 to 83). Of 47 patients, 45 had TCC of the urinary bladder and 7 of those had synchronous ureteral involvement. Two patients had ureteral TCC and a history of TCC of the bladder. Using fluorescence in situ hybridization, numerical aberrations of chromosomes 7, 9, and 17 were detected in imprint specimens of histologically verified tumor and "normal" urothelium and were compared with static ploidy and p53 and Ki67 expression. Chromosome 7 was altered in 93.6%, chromosome 9 in 63.8% (including monosomy), and chromosome 17 in 87.2% of the 47 analyzed tumor and normal imprints. Differences between tumor and normal epithelium were observed in aberrational frequencies (number of cells showing chromosomal aberrations calculated on 200 cells counted, given in percentages). DNA content was aneuploid in all tumor specimens, but diploid in 20 (42.5%) of 47 normal specimens, according to lower aberration frequencies in these patients. p53 detection was positive in 82.9% of the tumor specimens and 76.6% of the normal specimens. Ki67 was positive in 87.2% of the tumor imprints and in 72.3% of the normal specimens. These data suggest a general genetic instability as a reason for multifocality in the entire transitional epithelium.
Chang, Ronald; Folkerson, Lindley E; Sloan, Duncan; Tomasek, Jeffrey S; Kitagawa, Ryan S; Choi, H Alex; Wade, Charles E; Holcomb, John B
2017-02-01
Plasma-based resuscitation improves outcomes in trauma patients with hemorrhagic shock, while large-animal and limited clinical data suggest that it also improves outcomes and is neuroprotective in the setting of combined hemorrhage and traumatic brain injury. However, the choice of initial resuscitation fluid, including the role of plasma, is unclear for patients after isolated traumatic brain injury. We reviewed adult trauma patients admitted from January 2011 to July 2015 with isolated traumatic brain injury. "Early plasma" was defined as transfusion of plasma within 4 hours. Purposeful multiple logistic regression modeling was performed to analyze the relationship of early plasma and inhospital survival. After testing for interaction, subgroup analysis was performed based on the pattern of brain injury on initial head computed tomography: epidural hematoma, intraparenchymal contusion, subarachnoid hemorrhage, subdural hematoma, or multifocal intracranial hemorrhage. Of the 633 isolated traumatic brain injury patients included, 178 (28%) who received early plasma were injured more severely coagulopathic, hypoperfused, and hypotensive on admission. Survival was similar in the early plasma versus no early plasma groups (78% vs 84%, P = .08). After adjustment for covariates, early plasma was not associated with improved survival (odds ratio 1.18, 95% confidence interval 0.71-1.96). On subgroup analysis, multifocal intracranial hemorrhage was the largest subgroup with 242 patients. Of these, 61 (25%) received plasma within 4 hours. Within-group logistic regression analysis with adjustment for covariates found that early plasma was associated with improved survival (odds ratio 3.34, 95% confidence interval 1.20-9.35). Although early plasma transfusion was not associated with improved in-hospital survival for all isolated traumatic brain injury patients, early plasma was associated with increased in-hospital survival in those with multifocal intracranial hemorrhage. Copyright © 2016 Elsevier Inc. All rights reserved.
Luo, Xunda; Patel, Nimesh B.; Rajagopalan, Lakshmi P.; Harwerth, Ronald S.; Frishman, Laura J.
2014-01-01
Purpose. We investigated relations between macular retinal ganglion cell plus inner plexiform layer (RGC+IPL) thickness and macular retinal function revealed by multifocal electroretinonography (mfERG) in a nonhuman primate model of experimental glaucoma. Methods. Retinal ganglion cell (RGC) structure and function were followed with spectral-domain optical coherence tomography (SD-OCT) and ERGs in five macaques with unilateral experimental glaucoma. Linear regression was used to study correlations in control (Con) and experimental (Exp) eyes between peripapillary retinal nerve fiber layer (RNFL) thickness, macular RGC+IPL thickness, multifocal photopic negative response (mfPhNR) and high-frequency multifocal oscillatory potentials (mfOP) in slow-sequence mfERG, and low-frequency component (mfLFC) in global-flash mfERG. We used ANOVA and paired t-tests to compare glaucoma-related mfERG changes between superior and inferior hemifields, foveal hexagon, inner three rings, and four quadrants of macula. Results. Average macular RGC+IPL and temporal RNFL thickness were strongly correlated (r2 = 0.90, P < 0.001). In hexagon-by-hexagon analysis, all three mfERG measures were correlated (P < 0.001) with RGC+IPL thickness for Con (r2, 0.33–0.51) and Exp eyes (r2, 0.17–0.35). The RGC structural and functional metrics decreased as eccentricity increased. The reduction in amplitude of mfERG measures in Exp eyes relative to Con eyes was proportionally greater, in general, than the relative thinning of RGC+IPL at the same location for eyes in which structural loss was not evident, or mild to moderate. Although not statistically significant, percent amplitude reduction of mfERG measures was greatest in the inferior temporal quadrant. Conclusions. Macular RGC+IPL thickness and mfERG measures of RGC function can be complementary tools in assessing glaucomatous neuropathy. PMID:24970256
Kretz, Florian T A; Bastelica, Antoine; Carreras, Humberto; Ferreira, Tiago; Müller, Matthias; Gerl, Matthias; Gerl, Ralf; Saeed, Manzar; Schmickler, Stefanie; Auffarth, Gerd U
2015-03-01
To evaluate the clinical outcome in eyes with significant corneal astigmatism after cataract surgery with implantation of a new diffractive multifocal toric intraocular lens (IOL). Prospective, non-randomised multicentre clinical study including 57 eyes of 38 consecutive patients with an age between 37 and 84 years that underwent cataract surgery with implantation of the toric multifocal IOL Tecnis ZMT (Abbott Medical Optics, Santa Ana, California, USA). Changes in uncorrected and corrected logMAR distance, intermediate and near visual acuity ((uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA) uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), corrected near visual acuity) and manifest refraction were evaluated during a 2-4 month follow-up. Additionally, patients were asked about photic phenomena and spectacle dependence. The surgeons subjectively assessed various aspects of the surgery. A significant improvement in CDVA was observed postoperatively (p<0.01), with a significant reduction in manifest cylinder (p<0.01). Mean postoperative binocular UDVA and UNVA were 0.04±0.10 and 0.06±0.12, respectively. Monocular UDVA and UNVA was 0.20 or better in 85.4% and 87.0% of eyes, respectively. Mean binocular logMAR UIVA was 0.21±0.20. Only 10.5% of patients required postoperative correction for near or intermediate distance. The incidence of moderate to severe photic phenomena was limited. Surgeons defined the IOL implantation in most cases as easy or very easy, with a satisfaction rate with the procedure of 84%. The implantation of the multifocal toric IOL is a safe procedure that provides a very good visual rehabilitation in eyes with corneal astigmatism. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Su, Xuan; He, Caiyun; Ma, Jiangjun; Tang, Tao; Zhang, Xiao; Ye, Zulu; Long, Yakang; Shao, Qiong
2016-01-01
RET/PTC rearrangements, resulting in aberrant activity of the RET protein tyrosine kinase receptor, occur exclusively in papillary thyroid cancer (PTC). In this study, we examined the association between RET/PTC rearrangements and thyroid hormone homeostasis, and explored whether concomitant diseases such as nodular goiter and Hashimoto's thyroiditis influenced this association. A total of 114 patients diagnosed with PTC were enrolled in this study. Thyroid hormone levels, clinicopathological parameters and lifestyle were obtained through medical records and surgical pathology reports. RET/PTC rearrangements were detected using TaqMan RT-PCR and validated by direct sequencing. No RET/PTC rearrangements were detected in benign thyroid tissues. RET/PTC rearrangements were detected in 23.68% (27/114) of PTC tissues. No association between thyroid function, clinicopathological parameters and lifestyle was observed either in total thyroid cancer patients or the subgroup of patients with concomitant disease. In the subgroup of PTC patients without concomitant disease, RET/PTC rearrangement was associated with multifocal cancer (P = 0.018). RET/PTC rearrangement was also correlated with higher TSH levels at one month post-surgery (P = 0.037). Based on likelihood-ratio regression analysis, the RET/PTC-positive PTC cases showed an increased risk of multifocal cancers in the thyroid gland (OR = 5.57, 95% CI, 1.39–22.33). Our findings suggest that concomitant diseases such as nodular goiter and Hashimoto's thyroiditis in PTC may be a confounding factor when examining the effects of RET/PTC rearrangements. Excluding the potential effect of this confounding factor showed that RET/PTC may confer an increased risk for the development of multifocal cancers in the thyroid gland. Aberrantly increased post-operative levels of TSH were also associated with RET/PTC rearrangement. Together, our data provides useful information for the treatment of papillary thyroid cancer. PMID:27802347
Ruffini, Giulio; Fox, Michael D.; Ripolles, Oscar; Miranda, Pedro Cavaleiro; Pascual-Leone, Alvaro
2014-01-01
Recently, multifocal transcranial current stimulation (tCS) devices using several relatively small electrodes have been used to achieve more focal stimulation of specific cortical targets. However, it is becoming increasingly recognized that many behavioral manifestations of neurological and psychiatric disease are not solely the result of abnormality in one isolated brain region but represent alterations in brain networks. In this paper we describe a method for optimizing the configuration of multifocal tCS for stimulation of brain networks, represented by spatially extended cortical targets. We show how, based on fMRI, PET, EEG or other data specifying a target map on the cortical surface for excitatory, inhibitory or neutral stimulation and a constraint of the maximal number of electrodes, a solution can be produced with the optimal currents and locations of the electrodes. The method described here relies on a fast calculation of multifocal tCS electric fields (including components normal and tangential to the cortical boundaries) using a five layer finite element model of a realistic head. Based on the hypothesis that the effects of current stimulation are to first order due to the interaction of electric fields with populations of elongated cortical neurons, it is argued that the optimization problem for tCS stimulation can be defined in terms of the component of the electric field normal to the cortical surface. Solutions are found using constrained least squares to optimize current intensities, while electrode number and their locations are selected using a genetic algorithm. For direct current tCS (tDCS) applications, we provide some examples of this technique using an available tCS system providing 8 small Ag/AgCl stimulation electrodes. We demonstrate the approach both for localized and spatially extended targets defined using rs-fcMRI and PET data, with clinical applications in stroke and depression. Finally, we extend these ideas to more general stimulation protocols, such as alternating current tCS (tACS). PMID:24345389
Trpkov, Kiril; Athanazio, Daniel; Magi-Galluzzi, Cristina; Yilmaz, Helene; Clouston, David; Agaimy, Abbas; Williamson, Sean R; Brimo, Fadi; Lopez, Jose I; Ulamec, Monika; Rioux-Leclercq, Nathalie; Kassem, Maysoun; Gupta, Nilesh; Hartmann, Arndt; Leroy, Xavier; Bashir, Samir Al; Yilmaz, Asli; Hes, Ondřej
2018-04-01
To further characterise biphasic squamoid renal cell carcinoma (RCC), a recently proposed variant of papillary RCC. We identified 28 tumours from multiple institutions. They typically showed two cell populations-larger cells with eosinophilic cytoplasm and higher-grade nuclei, surrounded by smaller, amphophilic cells with scanty cytoplasm. The dual morphology was variable (median 72.5% of tumour, range 5-100%); emperipolesis was found in all cases. The male/female ratio was 2:1, and the median age was 55 years (range 39-86 years). The median tumour size was 20 mm (range 9-65 mm). Pathological stage pT1a was found in 21 cases, pT1b in three, and pT3a and pT3b in one each (two not available). Multifocality was found in 32%: multifocal biphasic RCC in one case, biphasic + papillary RCC in two cases, biphasic + clear cell RCC in three cases, biphasic + low-grade urothelial carcinoma of the renal pelvis in one case, and biphasic + Birt-Hogg-Dubé syndrome in one case. Positive immunostains included: PAX8, cytokeratin (CK) 7, α-methylacyl-CoA racemase, epithelial membrane antigen, and vimentin. Cyclin D1 was expressed only in the larger cells. The Ki67 index was higher in the larger cells (median 5% versus ≤1%). Negative stains included: carbonic anhydrase 9, CD117, GATA-3, WT1, CK5/6, and CK20; CD10 and 34βE12 were variably expressed. Gains of chromosomes 7 and 17 were found in two evaluated cases. Follow-up was available for 23 patients (median 24 months, range 1-244 months): 19 were alive without disease, one was alive with recurrence, and one had died of disease (two had died of other causes). Biphasic papillary RCC is a rare variant of papillary RCC, and is often multifocal. © 2017 John Wiley & Sons Ltd.
Fourier Plane Image Combination by Feathering
NASA Astrophysics Data System (ADS)
Cotton, W. D.
2017-09-01
Astronomical objects frequently exhibit structure over a wide range of scales whereas many telescopes, especially interferometer arrays, only sample a limited range of spatial scales. To properly image these objects, images from a set of instruments covering the range of scales may be needed. These images then must be combined in a manner to recover all spatial scales. This paper describes the feathering technique for image combination in the Fourier transform plane. Implementations in several packages are discussed and example combinations of single dish and interferometric observations of both simulated and celestial radio emission are given.
Human observers are biased in judging the angular approach of a projectile.
Welchman, Andrew E; Tuck, Val L; Harris, Julie M
2004-01-01
How do we decide whether an object approaching us will hit us? The optic array provides information sufficient for us to determine the approaching trajectory of a projectile. However, when using binocular information, observers report that trajectories near the mid-sagittal plane are wider than they actually are. Here we extend this work to consider stimuli containing additional depth cues. We measure observers' estimates of trajectory direction first for computer rendered, stereoscopically presented, rich-cue objects, and then for real objects moving in the world. We find that, under both rich cue conditions and with real moving objects, observers show positive bias, overestimating the angle of approach when movement is near the mid-sagittal plane. The findings question whether the visual system, using both binocular and monocular cues to depth, can make explicit estimates of the 3-D location and movement of objects in depth.
Direct view zoom scope with single focal plane and adaptable reticle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bagwell, Brett
A direct view telescopic sight includes objective lens, eyepiece, and prism erector assemblies. The objective lens assembly is mounted to receive light of an image from an object direction and direct the light along an optical path. The eyepiece assembly is mounted to receive the light along the optical path and to emit the light of the image along an eye-ward direction. The prism erector assembly is positioned between the objective lens and eyepiece assemblies and includes first and second prism elements through which the optical path passes. The first and second prism elements invert the image. A reticle elementmore » is disposed on or adjacent to a surface of one of the first or second prism elements to combine a reticle on the image. The image is brought into focus at only a single focal plane between the objective lens and eyepiece assemblies at a given time.« less
Treating presbyopia without spectacles
NASA Astrophysics Data System (ADS)
Xu, Renfeng
Both multifocal optics and small pupils can increase the depth of focus (DoF) of presbyopes. This thesis will evaluate some of the unique challenges faced by each of these two strategies. First, there is no single spherical refracting lens that can focus all parts of the pupil of an aberrated eye. What is the objective and subjective spherical refractive error (Rx) for such an eye, and does it vary with the amount of primary SA? Using both computational modeling and psychophysical methods, we found that high levels of positive Seidel SA caused both objective and subjective refractions to become myopic. Significantly, this refractive shift varied with stimulus spatial frequency and subjective criterion. Second, although secondary SA can dramatically expand DoF, we show that this is mostly due to the lower order components within this polynomial, which can also change spherical Rx. Also, the r6 term that defines secondary SA actually narrows rather than expands DoF, when in the presence of the r4 term within Z60. Finally, as retinal illuminance drops, neural thresholds are elevated due to increased problems of photon noise. We asked if the gains in near and distant vision of presbyopes anticipated at high light levels would be cancelled or even reversed at low light levels because of the additional reduction in retinal illuminance contributed by small pupils. We found that when light levels are > 2 cd/m2, a small pupil with a diameter of 2--3mm improves near image quality, near visual acuity, and near reading speed without significant loss of distance image quality and distance vision. This result gains added significance because we also showed that low light level text in the urban environment always has luminance levels > 2 cd/m2. In conclusion, both small pupils and multifocal optics face significant challenges as near vision aids for presbyopes. However, some of the confounding effects of elevated SA levels are avoided by using small pupils to expand DoF, which can provide improved near and distance vision at most light levels encountered while reading.
Trajectory optimization for the national aerospace plane
NASA Technical Reports Server (NTRS)
Lu, Ping
1993-01-01
During the past six months the research objectives outlined in the last semi-annual report were accomplished. Specifically, these are: three-dimensional (3-D) fuel-optimal ascent trajectory of the aerospace plane and the effects of thrust vectoring control (TVC) on the fuel consumption and trajectory shaping were investigated; the maximum abort landing area (footprint) was studied; preliminary assessment of simultaneous design of the ascent trajectory and the vehicle configuration for the aerospace plane was also conducted. The work accomplished in the reporting period is summarized.
Airborne antenna pattern calculations
NASA Technical Reports Server (NTRS)
Knerr, T. J.; Mielke, R. R.
1981-01-01
Progress on the development of modeling software, testing software against caclulated data from program VPAP and measured patterns, and calculating roll plane patterns for general aviation aircraft is reported. Major objectives are the continued development of computer software for aircraft modeling and use of this software and program OSUVOL to calculate principal plane and volumetric radiation patterns. The determination of proper placement of antennas on aircraft to meet the requirements of the Microwave Landing System is discussed. An overview of the performed work, and an example of a roll plane model for the Piper PA-31T Cheyenne aircraft and the resulting calculated roll plane radiation pattern are included.
Maschi, Célia; Schneider-Lise, Bérengère; Paoli, Vincent; Gastaud, Pierre
2011-06-01
Acute macular neuroretinopathy is a rare disease which occurs in young women and causes sudden paracentral scotoma and typical reddish-brown macular lesions. We report two cases of young women suffering from acute macular neuroretinopathy which we observed with spectral-domain Spectralis HRA-OCT and multifocal ERG at 3 and 7 months. Imaging revealed an early hyper-reflectivity of the photoreceptor layer, which changed into hyporeflectivity in the first week and remained the same in the following months, whereas visual field improved. Our findings show involvement primarly of the outer retina, and confirm OCT and mf ERG as important tools for diagnosis and follow-up of pathologic changes in AMNR, as other diagnostic tests often remain normal.
Ströhl, Florian; Kaminski, Clemens F
2015-01-16
We demonstrate the reconstruction of images obtained by multifocal structured illumination microscopy, MSIM, using a joint Richardson-Lucy, jRL-MSIM, deconvolution algorithm, which is based on an underlying widefield image-formation model. The method is efficient in the suppression of out-of-focus light and greatly improves image contrast and resolution. Furthermore, it is particularly well suited for the processing of noise corrupted data. The principle is verified on simulated as well as experimental data and a comparison of the jRL-MSIM approach with the standard reconstruction procedure, which is based on image scanning microscopy, ISM, is made. Our algorithm is efficient and freely available in a user friendly software package.
NASA Astrophysics Data System (ADS)
Ströhl, Florian; Kaminski, Clemens F.
2015-03-01
We demonstrate the reconstruction of images obtained by multifocal structured illumination microscopy, MSIM, using a joint Richardson-Lucy, jRL-MSIM, deconvolution algorithm, which is based on an underlying widefield image-formation model. The method is efficient in the suppression of out-of-focus light and greatly improves image contrast and resolution. Furthermore, it is particularly well suited for the processing of noise corrupted data. The principle is verified on simulated as well as experimental data and a comparison of the jRL-MSIM approach with the standard reconstruction procedure, which is based on image scanning microscopy, ISM, is made. Our algorithm is efficient and freely available in a user friendly software package.
Multifocal epithelial hyperplasia: a forgotten condition in the elderly.
Shamloo, Nafiseh; Mortazavi, Hamed; Taghavi, Nasim; Baharvand, Maryam
2016-01-01
Multifocal epithelial hyperplasia (MEH), also known as focal epithelial hyperplasia and Heck disease, is a relatively rare condition caused by the human papillomavirus. This case report describes a 92-year-old man who presented with multiple, asymptomatic, circumscribed, soft, flattened papules in different sizes on the retrocommissure of his lower lip. The lesions were of 2 months' duration and had the same coloration as the adjacent normal mucosa. Histopathologic examination showed orthokeratinized stratified squamous epithelium with acanthosis, some areas of club-shaped rete ridges, and a few superficial epithelial cells with koilocytic changes and a mitosoid-like appearance. A diagnosis of MEH was established. Although MEH tends to occur in the first 2 decades of life, it can be encountered in elderly patients as well.
High-throughput ultraviolet photoacoustic microscopy with multifocal excitation
NASA Astrophysics Data System (ADS)
Imai, Toru; Shi, Junhui; Wong, Terence T. W.; Li, Lei; Zhu, Liren; Wang, Lihong V.
2018-03-01
Ultraviolet photoacoustic microscopy (UV-PAM) is a promising intraoperative tool for surgical margin assessment (SMA), one that can provide label-free histology-like images with high resolution. In this study, using a microlens array and a one-dimensional (1-D) array ultrasonic transducer, we developed a high-throughput multifocal UV-PAM (MF-UV-PAM). Our new system achieved a 1.6 ± 0.2 μm lateral resolution and produced images 40 times faster than the previously developed point-by-point scanning UV-PAM. MF-UV-PAM provided a readily comprehensible photoacoustic image of a mouse brain slice with specific absorption contrast in ˜16 min, highlighting cell nuclei. Individual cell nuclei could be clearly resolved, showing its practical potential for intraoperative SMA.
2010-12-01
A European Federation of Neurological Societies/Peripheral Nerve Society consensus guideline on the definition, investigation, and treatment of multifocal motor neuropathy (MMN) was published in 2006. The aim is to revise this guideline. Disease experts considered references retrieved from MEDLINE and Cochrane Systematic Reviews published between August 2004 and July 2009 and prepared statements that were agreed to in an iterative fashion. The Task Force agreed on Good Practice Points to define clinical and electrophysiological diagnostic criteria for MMN, investigations to be considered, and principal recommendations for treatment. © 2010 Peripheral Nerve Society.
[Progressive multifocal leukoencephalitis complicating polymyositis].
Elloumi, Mohamed; Ayadi, Nada; Mhiri, Chokri; Jlidi, Rachid; Baklouti, Soufiène
2003-02-01
Progressive multifocal leukoencephalitis (PML) must be evoked in patients presenting with a systemic disease during which multiple neurological deficiencies rapidly worsen. A 17 year-old girl suffering from histologically confirmed polymyositis was treated with corticosteroids. Two years after the diagnosis she exhibited global signs of cerebral damage with fever and magnetic resonance imaging evoked leukoencephalitis. An affection of the central nervous system, PML is characterised by the existence of multiple areas of demyelination in the hemispheric white substance of the cerebral trunk and sometimes the cerebellum, whereas the grey substance is usually spared. This entity occurs more frequently in HIV-infected patients, but also in patients in whom the immunodeficiency may have other causes, such as the treatment for a systemic disease for example.
[Current recommendations for deceleration of myopia progression].
Lagrèze, W A; Joachimsen, L; Schaeffel, F
2017-01-01
Epidemiologic data demonstrate a rise in myopia prevalence. Therefore interventions to reduce the risk of myopia and its progression are needed and increasingly often asked for. Systematic literature search via PubMed in MEDLINE. Myopia progression can be reduced by the following means which are listed according to their efficacy: (1) Atropine eye drops low dosed to avoid clinically relevant side effects, (2) optical means aiming at the correction of peripheral hyperopic defocus, e. g., multifocal contact lenses, and (3) increased daylight exposure. Daylight exposure reduces the risk of incident myopia. Children should be advised to spend sufficient time outdoors, especially before and in primary school. Myopia progression can be effectively attenuated by low-dose topical atropine and multifocal contact lenses.
Chronic recurrent multifocal osteomyelitis exhibiting predominance of periosteal reaction.
Queiroz, Rodolfo Mendes; Rocha, Pedro Henrique Pereira; Lauar, Lara Zupelli; Costa, Mauro José Brandão da; Laguna, Claudio Benedini; Oliveira, Rafael Gouvêa Gomes de
2017-04-01
Chronic recurrent multifocal osteomyelitis is an idiopathic nonpyogenic autoinflammatory bone disorder involving multiple sites, with clinical progression persisting for more than 6 months and which may have episodes of remission and exacerbation in the long term. It represents up to 2-5% of the cases of osteomyelitis, with an approximate incidence of up to 4/1,000,000 individuals, and average age of disease onset estimated between 8-11 years, predominantly in females. The legs are the most affected, with a predilection for metaphyseal regions along the growth plate. We describe the case of a female patient, aged 2 years and 5 months, with involvement of the left ulna, right jaw and left tibia, showing a predominance of periosteal reaction as main finding.
NASA Astrophysics Data System (ADS)
DiCarlo, Cheryl D.; Brown, Jeremiah; Grado, Andres; Sankovich, James; Zwick, Harry; Lund, David J.; Stuck, Bruce E.
2004-07-01
There is no uniformly accepted objective method to diagnose the functional extent of retinal damage following laser eye injury and there is no uniform therapy for laser retinal injury. J.T. Eells, et al, reported the use of Light Emitting Diodes (LED) photoillumination (670 nm) for methanol-induced retinal toxicity in rats. The findings indicated a preservation of retinal architecture, as determined by histopathology and a partial functional recovery of photoreceptors, as determined by electroretinogram (ERG), in the LED exposed methanol-intoxicated rats. The purpose of this study is to use multifocal electroretinography (mfERG) to evaluate recovery of retinal function following treatment with LED photoillumination in a cynomolgus monkey laser retinal injury model. Control and LED array (670 nm) illuminated animals received macular Argon laser lesions (514 nm, 130 mW, 100 ms). LED array exposure was accomplished for 4 days for a total dose of 4 J/cm2 per day. Baseline and post-laser exposure mfERGs were performed. mfERG results for five animals post-laser injury but prior to treatment (Day 0) showed increased implicit times and P1 waveform amplitudes when compared to a combined laboratory normal and each animal's baseline normal values. In general, preliminary mfERG results of our first five subjects recorded using both the 103-hexagon and 509-hexagon patterns indicate a more rapid functional recovery in the LED illuminated animal as compared to the control by the end of the fourth day post-exposure. Research is continuing to determine if this difference in functional return is seen in additional subjects and if statistical significance exists.
Galban-Horcajo, Francesc; Vlam, Lotte; Delmont, Emilien; Halstead, Susan K.; van den Berg, Leonard; van der Pol, W-Ludo; Willison, Hugh J.
2015-01-01
Abstract Background: Multifocal motor neuropathy (MMN) is associated with IgM antibodies to GM1 ganglioside. The importance of the lipid milieu that might facilitate or inhibit antibody binding to GM1 in immunoassays is well recognised. Existing studies, using a range of different approaches, generally concur that anti-GM1 IgM antibody detection rates are improved by the addition of galactocerebroside (GalC) to the GM1 assay. Objective: The current study sought to formally evaluate the clinical utility of the GM1:GalC complex assay in the diagnosis of MMN. Methods: Anti-GM1 and -GM1:GalC antibodies were examined using ELISA and glycoarray (dot blot) in a fully blinded study design, consisting of 100 MMN patients, 100 ALS cases and 100 healthy controls. Results: The detection of anti-GM1 Abs using glycoarray was 67% sensitive and 85% specific. The addition of GalC to GM1, (1:1 weight to weight ratio), increased the sensitivity to 81% , whilst dropping specificity to 80% . Increasing the GalC content to a 1:5 ratio (or higher) further decreased specificity, and in doing so limited the usefulness of the GM1:GalC assay to the level of GM1 alone. The addition of GalC to the ELISA method also significantly increased sensitivity compared with GM1 alone, albeit with a significant decrease in specificity. Conclusions: This study indicates that the GM1:GalC assay is an advantageous assay adaptation for detecting anti-GM1 antibodies in MMN, using either glycoarray or ELISA, and warrants introduction into clinical diagnostic practice. PMID:27858734
Jayaraman, Manju; Gandhi, Rashmin Anilkumar; Ravi, Priya; Sen, Parveen
2014-01-01
Purpose: To investigate the effect of optic neuritis (ON), ischemic optic neuropathy (ION) and compressive optic neuropathy (CON) on multifocal visual evoked potential (mfVEP) amplitudes and latencies, and to compare the parameters among three optic nerve disorders. Materials and Methods: mfVEP was recorded for 71 eyes of controls and 48 eyes of optic nerve disorders with subgroups of optic neuritis (ON, n = 21 eyes), ischemic optic neuropathy (ION, n = 14 eyes), and compressive optic neuropathy (CON, n = 13 eyes). The size of defect in mfVEP amplitude probability plots and relative latency plots were analyzed. The pattern of the defect in amplitude probability plot was classified according to the visual field profile of optic neuritis treatment trail (ONTT). Results: Median of mfVEP amplitude (log SNR) averaged across 60 sectors were reduced in ON (0.17 (0.13-0.33)), ION (0.14 (0.12-0.21)) and CON (0.21 (0.14-0.30)) when compared to controls. The median mfVEP relative latencies compared to controls were significantly prolonged in ON and CON group of 10.53 (2.62-15.50) ms and 5.73 (2.67-14.14) ms respectively compared to ION group (2.06 (-4.09-13.02)). The common mfVEP amplitude defects observed in probability plots were diffuse pattern in ON, inferior altitudinal defect in ION and temporal hemianopia in CON eyes. Conclusions: Optic nerve disorders cause reduction in mfVEP amplitudes. The extent of delayed latency noted in ischemic optic neuropathy was significantly lesser compared to subjects with optic neuritis and compressive optic neuropathy. mfVEP amplitudes can be used to objectively assess the topography of the visual field defect. PMID:24088641
Moschos, Marilita M; Nitoda, Eirini; Chatziralli, Irini P; Gatzioufas, Zisis; Koutsandrea, Chryssanthi; Kitsos, George
2015-01-01
Objective This study was conducted to evaluate the macular status of patients treated with hydroxychloroquine before and after cessation of treatment. Methods Forty-two patients with systemic lupus erythematosus underwent ocular examination based on visual acuity evaluation, optical coherence tomography retinal thickness measurements, and multifocal electroretinography (mfERG) records at first visit. The tests were repeated 6 months after treatment withdrawal and compared to the findings at their first visit. Results Mean visual acuity (measured in log minimum angle of resolution) of both eyes was statistically increased after hydroxychloroquine discontinuation (difference in means: 0.06 [P<0.0001] and 0.01 [P=0.003] for the right and left eyes, respectively). Retinal response amplitudes of central and peripheral areas were significantly improved for both eyes. The following values were observed for central responses: the difference in means was −19.9 (P<0.0001) and −13.6 (P<0.0001) for the right eye and the left eye, respectively; for peripheral responses, difference in means was −10.3 (P<0.0001) and −9.5 (P<0.0001) for right eye and left eye, respectively, after the 6-month examination. There were no statistically significant differences in the retinal thickness of patients after cessation of treatment. The visual acuity of the patients was correlated to central and peripheral mfERG responses (r=−0.53 [P<0.0001] and r=−0.53 [P<0.0001], for the right eye and the left eye, respectively). Conclusion The visual acuity of patients receiving hydroxychloroquine improves along with the amplitudes of the mfERG responses 6 months after discontinuation of the drug, but no difference in retinal thickness is identified. PMID:26089648
Thyroid scintigraphy findings in 2096 cats with hyperthyroidism.
Peterson, Mark E; Broome, Michael R
2015-01-01
Thyroid scintigraphy is currently the reference standard for diagnosing and staging cats with hyperthyroidism, but few studies describing the scintigraphic characteristics in a large number of cats have been reported. The objective of this study was to better characterize thyroid scintigraphy findings by evaluating 2096 consecutive cats with hyperthyroidism that were referred over a 3.5-year period. Of these cats, 2068 (98.7%) had a high thyroid-to-salivary ratio (>1.5), whereas 2014 (96.1%) were found to have a high thyroid-to-background ratio (>6.1). When the patterns of the cats' thyroid disease were recorded, 665 (31.7%) had unilateral disease, 1060 (50.6%) had bilateral-asymmetric disease (two thyroid lobes unequal in size), 257 (12.3%) had bilateral-symmetric disease (both lobes similar in size), and 81 (3.9%) had multifocal disease (≥3 areas of increased radionuclide uptake). The number of areas of (99m) TcO(-) 4 uptake in the 2096 cats ranged from 1 to 6 (median, 2), located in the cervical area in 2057 (98.1%), thoracic inlet in 282 (13.5%), and in the thoracic cavity in 115 (5.5%). Ectopic thyroid tissue (e.g. lingual or mediastinal) was diagnosed in 81 (3.9%) cats, whereas thyroid carcinoma was suspected in 35 (1.7%) of the cats. The results of this study support conclusions that most hyperthyroid cats have unilateral or bilateral thyroid nodules, but that multifocal disease will develop in a few cats that have ectopic thyroid disease or thyroid carcinoma. Both ectopic thyroid disease and thyroid carcinoma are relatively uncommon in hyperthyroid cats, with a respective prevalence of ∼4% and ∼2% in this study. © 2014 American College of Veterinary Radiology.
2018-01-01
Objective To study the performance of multifocal-visual-evoked-potential (mfVEP) signals filtered using empirical mode decomposition (EMD) in discriminating, based on amplitude, between control and multiple sclerosis (MS) patient groups, and to reduce variability in interocular latency in control subjects. Methods MfVEP signals were obtained from controls, clinically definitive MS and MS-risk progression patients (radiologically isolated syndrome (RIS) and clinically isolated syndrome (CIS)). The conventional method of processing mfVEPs consists of using a 1–35 Hz bandpass frequency filter (XDFT). The EMD algorithm was used to decompose the XDFT signals into several intrinsic mode functions (IMFs). This signal processing was assessed by computing the amplitudes and latencies of the XDFT and IMF signals (XEMD). The amplitudes from the full visual field and from ring 5 (9.8–15° eccentricity) were studied. The discrimination index was calculated between controls and patients. Interocular latency values were computed from the XDFT and XEMD signals in a control database to study variability. Results Using the amplitude of the mfVEP signals filtered with EMD (XEMD) obtains higher discrimination index values than the conventional method when control, MS-risk progression (RIS and CIS) and MS subjects are studied. The lowest variability in interocular latency computations from the control patient database was obtained by comparing the XEMD signals with the XDFT signals. Even better results (amplitude discrimination and latency variability) were obtained in ring 5 (9.8–15° eccentricity of the visual field). Conclusions Filtering mfVEP signals using the EMD algorithm will result in better identification of subjects at risk of developing MS and better accuracy in latency studies. This could be applied to assess visual cortex activity in MS diagnosis and evolution studies. PMID:29677200
Demidchik, Yuri E.; Demidchik, Eugene P.; Reiners, Christoph; Biko, Johannes; Mine, Mariko; Saenko, Vladimir A.; Yamashita, Shunichi
2006-01-01
Objective: A retrospective study was designed to evaluate the results of surgical treatment and follow-up data in thyroid cancer patients less than 15 years old at the time of surgery. Summary Background Data: Pediatric thyroid carcinomas have a high rate of lymph nodal and distant metastases. Risk factors for recurrences and postoperative morbidity have not been assessed yet in a representative series. Methods: The group included 740 pediatric patients with thyroid cancer. Total thyroidectomy was performed in 426 (57.6%), lobectomy in 248 (33.5%), subtotal thyroidectomy in 58 (7.8%) cases, and 8 patients (1.1%) underwent partial lobectomy. Results: The mean follow-up period was 115.8 months (range, 1.5–236.4 months). Recurrence was diagnosed in 204 cases (27.6%), including 73 local relapses (9.9%), 90 distant metastases (12.2%), and a combination of local and distant recurrences in 41 (5.5%) patients. Multivariate statistical assessment revealed the following independent parameters significantly associated with the risk of recurrent nodal disease: a young age at diagnosis, multifocal carcinomas, N1 status, and lack of neck lymph node dissection. For lung metastases, the significant risk factors were female gender, young age at diagnosis, and presence of symptoms. The observed 5- and 10-year survival for the entire group was 99.5% and 98.8%, respectively. Postoperative hypoparathyroidism was significantly associated with multifocal tumors, central compartment removal, and ipsilateral dissection. Conclusions: Total thyroidectomy followed by radioiodine therapy is an optimal treatment strategy that makes it possible to achieve a cure in a vast majority of pediatric patients with differentiated thyroid carcinomas. Risk of recurrence is strongly associated with tumor stage, extent of surgery, the young patient's age, and presence of symptoms at diagnosis. PMID:16552205
Open Cluster Dynamics via Fundamental Plane
NASA Astrophysics Data System (ADS)
Lin, Chien-Cheng; Pang, Xiao-Ying
2018-04-01
Open clusters (OCs) are important objects for stellar dynamics studies. The short survival timescale of OCs makes them closely related to the formation of Galactic field stars. We motivate to investigate the dynamical evolution of OCs on the aspect of internal effect and the external influence. Firstly, we make use of the known OC catalog to obtain OCs masses, effective radii. Additionally, we estimate OCs kinematics properties by OC members cross-matched with radial velocity and metallicity from SDSSIV/APOGEE2. We then establish the fundamental plane of OCs based on the radial velocity dispersion, the effective radius, and average surface brightness. The deviation of the fundamental plane from the Virial Plane, so called the tilt, and the r.m.s. dispersion of OCs around the average plane are used to indicate the dynamical status of OCs. Parameters of the fitted plane will vary with cluster age and distance.
Radiation-Induced Transient Effects in Near Infrared Focal Plane Arrays
NASA Technical Reports Server (NTRS)
Reed, Robert A.; Pickel, J.; Marshall, P.; Waczynski, A.; McMurray, R.; Gee, G.; Polidan, E.; Johnson, S.; McKeivey, M.; Ennico, K.;
2004-01-01
This viewgraph presentation describes a test simulate the transient effects of cosmic ray impacts on near infrared focal plane arrays. The objectives of the test are to: 1) Characterize proton single events as function of energy and angle of incidence; 2) Measure charge spread (crosstalk) to adjacent pixels; 3) Assess transient recovery time.
Understanding the Conics through Augmented Reality
ERIC Educational Resources Information Center
Salinas, Patricia; Pulido, Ricardo
2017-01-01
This paper discusses the production of a digital environment to foster the learning of conics through augmented reality. The name conic refers to curves obtained by the intersection of a plane with a right circular conical surface. The environment gives students the opportunity to interact with the cone and the plane as virtual objects in real…
System alignment using the Talbot effect
NASA Astrophysics Data System (ADS)
Chevallier, Raymond; Le Falher, Eric; Heggarty, Kevin
1990-08-01
The Talbot effect is utilized to correct an alignment problem related to a neural network used for image recognition, which required the alignment of a spatial light modulator (SLM) with the input module. A mathematical model which employs the Fresnel diffraction theory is presented to describe the method. The calculation of the diffracted amplitude describes the wavefront sphericity and the original object transmittance function in order to qualify the lateral shift of the Talbot image. Another explanation is set forth in terms of plane-wave illumination in the neural network. Using a Fourier series and by describing planes where all the harmonics are in phase, the reconstruction of Talbot images is explained. The alignment is effective when the lenslet array is aligned on the even Talbot images of the SLM pixels and the incident wave is a plane wave. The alignment is evaluated in terms of source and periodicity errors, tilt of the incident plane waves, and finite object dimensions. The effects of the error sources are concluded to be negligible, the lenslet array is shown to be successfully aligned with the SLM, and other alignment applications are shown to be possible.
Noise reduction in digital holography based on a filtering algorithm
NASA Astrophysics Data System (ADS)
Zhang, Wenhui; Cao, Liangcai; Zhang, Hua; Jin, Guofan; Brady, David
2018-02-01
Holography is a tool to record the object wavefront by interference. Complex amplitude of the object wave is coded into a two dimensional hologram. Unfortunately, the conjugate wave and background wave would also appear at the object plane during reconstruction, as noise, which blurs the reconstructed object. From the perspective of wave, we propose a filtering algorithm to get a noise-reduced reconstruction. Due to the fact that the hologram is a kind of amplitude grating, three waves would appear when reconstruction, which are object wave, conjugate wave and background wave. The background is easy to eliminate by frequency domain filtering. The object wave and conjugate wave are signals to be dealt with. These two waves, as a whole, propagate in the space. However, when detected at the original object plane, the object wave would diffract into a sparse pattern while the conjugate wave would diffract into a diffused pattern forming the noise. Hence, the noise can be reduced based on these difference with a filtering algorithm. Both amplitude and phase distributions are truthfully retrieved in our simulation and experimental demonstration.
Efficient characterization of phase space mapping in axially symmetric optical systems
NASA Astrophysics Data System (ADS)
Barbero, Sergio; Portilla, Javier
2018-01-01
Phase space mapping, typically between an object and image plane, characterizes an optical system within a geometrical optics framework. We propose a novel conceptual frame to characterize the phase mapping in axially symmetric optical systems for arbitrary object locations, not restricted to a specific object plane. The idea is based on decomposing the phase mapping into a set of bivariate equations corresponding to different values of the radial coordinate on a specific object surface (most likely the entrance pupil). These equations are then approximated through bivariate Chebyshev interpolation at Chebyshev nodes, which guarantees uniform convergence. Additionally, we propose the use of a new concept (effective object phase space), defined as the set of points of the phase space at the first optical element (typically the entrance pupil) that are effectively mapped onto the image surface. The effective object phase space provides, by means of an inclusion test, a way to avoid tracing rays that do not reach the image surface.
Multiple degree of freedom object recognition using optical relational graph decision nets
NASA Technical Reports Server (NTRS)
Casasent, David P.; Lee, Andrew J.
1988-01-01
Multiple-degree-of-freedom object recognition concerns objects with no stable rest position with all scale, rotation, and aspect distortions possible. It is assumed that the objects are in a fairly benign background, so that feature extractors are usable. In-plane distortion invariance is provided by use of a polar-log coordinate transform feature space, and out-of-plane distortion invariance is provided by linear discriminant function design. Relational graph decision nets are considered for multiple-degree-of-freedom pattern recognition. The design of Fisher (1936) linear discriminant functions and synthetic discriminant function for use at the nodes of binary and multidecision nets is discussed. Case studies are detailed for two-class and multiclass problems. Simulation results demonstrate the robustness of the processors to quantization of the filter coefficients and to noise.
Micro-vibration detection with heterodyne holography based on time-averaged method
NASA Astrophysics Data System (ADS)
Qin, XiaoDong; Pan, Feng; Chen, ZongHui; Hou, XueQin; Xiao, Wen
2017-02-01
We propose a micro-vibration detection method by introducing heterodyne interferometry to time-averaged holography. This method compensates for the deficiency of time-average holography in quantitative measurements and widens its range of application effectively. Acousto-optic modulators are used to modulate the frequencies of the reference beam and the object beam. Accurate detection of the maximum amplitude of each point in the vibration plane is performed by altering the frequency difference of both beams. The range of amplitude detection of plane vibration is extended. In the stable vibration mode, the distribution of the maximum amplitude of each point is measured and the fitted curves are plotted. Hence the plane vibration mode of the object is demonstrated intuitively and detected quantitatively. We analyzed the method in theory and built an experimental system with a sine signal as the excitation source and a typical piezoelectric ceramic plate as the target. The experimental results indicate that, within a certain error range, the detected vibration mode agrees with the intrinsic vibration characteristics of the object, thus proving the validity of this method.
Novel Fourier-domain constraint for fast phase retrieval in coherent diffraction imaging.
Latychevskaia, Tatiana; Longchamp, Jean-Nicolas; Fink, Hans-Werner
2011-09-26
Coherent diffraction imaging (CDI) for visualizing objects at atomic resolution has been realized as a promising tool for imaging single molecules. Drawbacks of CDI are associated with the difficulty of the numerical phase retrieval from experimental diffraction patterns; a fact which stimulated search for better numerical methods and alternative experimental techniques. Common phase retrieval methods are based on iterative procedures which propagate the complex-valued wave between object and detector plane. Constraints in both, the object and the detector plane are applied. While the constraint in the detector plane employed in most phase retrieval methods requires the amplitude of the complex wave to be equal to the squared root of the measured intensity, we propose a novel Fourier-domain constraint, based on an analogy to holography. Our method allows achieving a low-resolution reconstruction already in the first step followed by a high-resolution reconstruction after further steps. In comparison to conventional schemes this Fourier-domain constraint results in a fast and reliable convergence of the iterative reconstruction process. © 2011 Optical Society of America
Kim, Hak-Jin; Kim, Bong Chul; Kim, Jin-Geun; Zhengguo, Piao; Kang, Sang Hoon; Lee, Sang-Hwy
2014-03-01
The objective of this study was to determine the reliable midsagittal (MS) reference plane in practical ways for the three-dimensional craniofacial analysis on three-dimensional computed tomography images. Five normal human dry skulls and 20 normal subjects without any dysmorphoses or asymmetries were used. The accuracies and stability on repeated plane construction for almost every possible candidate MS plane based on the skull base structures were examined by comparing the discrepancies in distances and orientations from the reference points and planes of the skull base and facial bones on three-dimensional computed tomography images. The following reference points of these planes were stable, and their distribution was balanced: nasion and foramen cecum at the anterior part of the skull base, sella at the middle part, and basion and opisthion at the posterior part. The candidate reference planes constructed using the aforementioned reference points were thought to be reliable for use as an MS reference plane for the three-dimensional analysis of maxillofacial dysmorphosis.
McCullough, D P; Gudla, P R; Harris, B S; Collins, J A; Meaburn, K J; Nakaya, M A; Yamaguchi, T P; Misteli, T; Lockett, S J
2008-05-01
Communications between cells in large part drive tissue development and function, as well as disease-related processes such as tumorigenesis. Understanding the mechanistic bases of these processes necessitates quantifying specific molecules in adjacent cells or cell nuclei of intact tissue. However, a major restriction on such analyses is the lack of an efficient method that correctly segments each object (cell or nucleus) from 3-D images of an intact tissue specimen. We report a highly reliable and accurate semi-automatic algorithmic method for segmenting fluorescence-labeled cells or nuclei from 3-D tissue images. Segmentation begins with semi-automatic, 2-D object delineation in a user-selected plane, using dynamic programming (DP) to locate the border with an accumulated intensity per unit length greater that any other possible border around the same object. Then the two surfaces of the object in planes above and below the selected plane are found using an algorithm that combines DP and combinatorial searching. Following segmentation, any perceived errors can be interactively corrected. Segmentation accuracy is not significantly affected by intermittent labeling of object surfaces, diffuse surfaces, or spurious signals away from surfaces. The unique strength of the segmentation method was demonstrated on a variety of biological tissue samples where all cells, including irregularly shaped cells, were accurately segmented based on visual inspection.
Damstra, Janalt; Fourie, Zacharias; De Wit, Marnix; Ren, Yijin
2012-02-01
Morphometric methods are used in biology to study object symmetry in living organisms and to determine the true plane of symmetry. The aim of this study was to determine if there are clinical differences between three-dimensional (3D) cephalometric midsagittal planes used to describe craniofacial asymmetry and a true symmetry plane derived from a morphometric method based on visible facial features. The sample consisted of 14 dry skulls (9 symmetric and 5 asymmetric) with metallic markers which were imaged with cone-beam computed tomography. An error study and statistical analysis were performed to validate the morphometric method. The morphometric and conventional cephalometric planes were constructed and compared. The 3D cephalometric planes constructed as perpendiculars to the Frankfort horizontal plane resembled the morphometric plane the most in both the symmetric and asymmetric groups with mean differences of less than 1.00 mm for most variables. However, the standard deviations were often large and clinically significant for these variables. There were clinically relevant differences (>1.00 mm) between the different 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features. The difference between 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features were clinically relevant. Care has to be taken using cephalometric midsagittal planes for diagnosis and treatment planning of craniofacial asymmetry as they might differ from the true plane of symmetry as determined by morphometrics.
[Evaluation of central lymph node dissection for papillary thyroid carcinoma in cN0 T1/T2].
Zhao, S Y; Ma, Y H; Yin, Z; Zhan, X X; Cheng, R C; Qian, J
2018-02-07
Objective: To evaluate the application of the central lymph node dissection (CLND) for papillary thyroid carcinoma (PTC) in cN0 T1/T2. Methods: Retrospective analysis of 532 cases with PTC in cN0 T1/T2 who underwent CLND between October 2014 and September 2016 in the Department of Thyroid Surgery, the First Affiliated Hospital of the Kunming Medical University. The incidence of central lymph node (CLN) metastasis and risk factors were analyzed. Results: CLN metastasis rates: 41.2% (42/102) in males vs 34.9% (150/430) in females, P =0.252; 33.9% (116/342) in single focal carcinoma vs 40.4% (74/183) in multifocal carcinoma, P =0.157; 44.0% (125/284) in patients with 45 years old or less vs 27.0% (67/248) in patients more than 45 years old, P =0.000; 30.3% (113/373) in microcarcinoma vs 50.9% (81/159) in non-microcarcinoma, P =0.000.In unilateral lesions, ipsilateral CLN metastasis was correlated with the tumor diameter ( P =0.012), but not with the number of lesions ( P =0.653). also contralateral CLN metastasis was correlated with the tumor diameter ( P =0.000), but not with the number of lesions ( P =0.815). For the left or right unilateral single focal lesion, the tumor diameter was not correlated with the metastasis of the posterior to right recurrent laryngeal nerve central lymph nodes (LN-prRLN-CLN) ( P =0.652, P =0.088). But in bilateral multifocal carcinoma the tumor diameter was correlated with metastasis of LN-prRLN-CLN ( P =0.039). Conclusions: Prophylactic CLND is reasonable for PTC in cN0 T1/T2. A bilateral CLND should be conducted for patients with bilateral multi-focus cancer and unilateral or bilateral non-microcarcinoma, especially in patients more than 45 years old. For unilateral single focal microcarcinoma on the right, the content of CLND should be from laryngeal nerve on right center to posterior branche; for unilateral single focal microcarcinoma on the left side, the left CLND should be conducted. An ipsilateral CLND can be considered in patients with unilateral multifocal microcarcinoma, and generally a routine dissection of the LN-prRLN-CLN is not required, however for bilateral non-microcarcinoma and the the non-microcarcinoma on the right side, the LN-prRLN-CLN dissection should be conducted.
Normal aging delays and compromises early multifocal visual attention during object tracking.
Störmer, Viola S; Li, Shu-Chen; Heekeren, Hauke R; Lindenberger, Ulman
2013-02-01
Declines in selective attention are one of the sources contributing to age-related impairments in a broad range of cognitive functions. Most previous research on mechanisms underlying older adults' selection deficits has studied the deployment of visual attention to static objects and features. Here we investigate neural correlates of age-related differences in spatial attention to multiple objects as they move. We used a multiple object tracking task, in which younger and older adults were asked to keep track of moving target objects that moved randomly in the visual field among irrelevant distractor objects. By recording the brain's electrophysiological responses during the tracking period, we were able to delineate neural processing for targets and distractors at early stages of visual processing (~100-300 msec). Older adults showed less selective attentional modulation in the early phase of the visual P1 component (100-125 msec) than younger adults, indicating that early selection is compromised in old age. However, with a 25-msec delay relative to younger adults, older adults showed distinct processing of targets (125-150 msec), that is, a delayed yet intact attentional modulation. The magnitude of this delayed attentional modulation was related to tracking performance in older adults. The amplitude of the N1 component (175-210 msec) was smaller in older adults than in younger adults, and the target amplification effect of this component was also smaller in older relative to younger adults. Overall, these results indicate that normal aging affects the efficiency and timing of early visual processing during multiple object tracking.
Munk, Marion R.; Jung, Jesse J.; Biggee, Kristin; Tucker, William R.; Sen, H. Nida; Schmidt-Erfurth, Ursula; Fawzi, Amani A.; Jampol, Lee M.
2014-01-01
Purpose To report acute/subacute vision loss and paracentral scotomata in patients with idiopathic multifocal choroiditis/punctate inner choroidopathy (MFC/PIC) due to large zones of acute photoreceptor attenuation surrounding the chorioretinal lesions. Methods Multimodal-imaging case-series Results Six females and 2 males were included (mean age 31.5±5.8 years). Vision ranged from 20/20-1 to hand motion (mean 20/364). SD-OCT demonstrated extensive attenuation of the external limiting membrane (ELM), ellipsoid and interdigitation zones, adjacent to the visible MFC/PIC lesions. The corresponding areas were hyperautofluorescent on fundus-autofluorescence (FAF), and were associated with corresponding visual field defects. Full-field ERG (available in 3 cases) showed markedly decreased cone/rod response and multifocal ERG revealed reduced amplitudes and increased implicit times in 2 cases. Three patients received no treatment, the remaining were treated with oral corticosteroids (n=4), oral acyclovir/valacyclovir (n=2), intravitreal/posterior subtenon triamcinolone-acetate (n=3) and anti-VEGF (n=2). Visual recovery occurred in only 3 cases, of whom 2 were treated. Varying morphological recovery was found in 6 cases, associated with decrease in hyperautofluorescence on FAF. Conclusions MFC/PIC can present with transient or permanent central photoreceptor attenuation/loss. This presentation is likely a variant of MFC/PIC with chorioretinal atrophy. Associated changes are best evaluated using multimodal imaging. PMID:25322466
Ventura, Dora F; Costa, Marcelo T V; Costa, Marcelo F; Berezovsky, Adriana; Salomão, Solange R; Simões, Ana Luíza; Lago, Marcos; Pereira, Luiz H M Canto; Faria, Marcília A M; De Souza, John M; Silveira, Luiz Carlos L
2004-01-01
We evaluated the color vision of mercury-contaminated patients and investigated possible retinal origins of losses using electroretinography. Participants were retired workers from a fluorescent lamp industry diagnosed with mercury contamination (n = 43) and age-matched controls (n = 21). Color discrimination was assessed with the Cambridge Colour Test (CCT). Retinal function was evaluated by using the ISCEV protocol for full-field electroretinography (full-field ERG), as well as by means of multifocal electroretinography (mfERG). Color-vision losses assessed by the CCT consisted of higher color-discrimination thresholds along the protan, deutan, and tritan axes and significantly larger discrimination ellipses in mercury-exposed patients compared to controls. Full-field ERG amplitudes from patients were smaller than those of the controls for the scotopic response b-wave, maximum response, sum of oscillatory potentials (OPs), 30-Hz flicker response, and light-adapted cone response. OP amplitudes measured in patients were smaller than those of controls for O2 and O3. Multifocal ERGs recorded from ten randomly selected patients showed smaller N1-P1 amplitudes and longer latencies throughout the 25-deg central field. Full-field ERGs showed that scotopic, photopic, peripheral, and midperipheral retinal functions were affected, and the mfERGs indicated that central retinal function was also significantly depressed. To our knowledge, this is the first demonstration of retinal involvement in visual losses caused by mercury toxicity.
The development of proliferative verrucous leukoplakia in oral lichen planus. A preliminary study
Llorente-Pendás, Santiago; González-Garcia, Manuel; García-Martín, José-Manuel
2016-01-01
Background Was to describe 14 cases of a proliferative verrucous leukoplakia as a clinical evolution of oral lichen planus. Material and Methods The clinical and histopathological characteristics of 14 cases of OLP that progress towards a plaque-like and verrucous form were indicated, with monitoring over a period of six to 24.3 years. Results The female/male ratio was 11/3, (78.6 and 21.4%). The mean age when the first biopsy was undertaken was 56.4 years old. None of the patients smoked during the study. As bilateral reticular was clinically diagnostic criterion, the second most frequent clinical form was the plaque form (n=10; 71.4%), followed by the atrophic (n=6; 42.8%), and erosive forms (n=4; 28.5%). Clinically it spread towards attached gingival mucosa and the hard palate. In the histopathologic study, there were a predominance of hyperkeratosis and verrucous epithelial hyperplasia. Three of the cases progressed to a squamous cell carcinoma, and one patient developed two verrucous carcinoma. Conclusions Further research is needed to demonstrate if proliferative multifocal oral lichen planus and proliferative multifocal oral leukoplakia are the same disorder but have different behaviour of malignancy for reasons of origin. Key words:Oral lichen planus, proliferative verrucous oral leukoplakia, malignant oral lichen planus, multifocal verrucous oral lichen planus, proliferative verrucous oral lichen planus. PMID:27031060
Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses
Unsal, Ugur; Baser, Gonen
2016-01-01
Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p = 0.50 and p = 0.509, resp.). The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p = 0.049, p = 0.005, and p = 0.001, resp.) and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p = 0.001). The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities), whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading). PMID:27340560
Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru
2016-02-01
To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P < .05). Statistically significant correlations were present between preoperative pupil diameters and postoperative visual acuities (Rs > 0; P < .05). Patients with a larger pupil always have better postoperative visual acuities. Meanwhile, there was no statistically significant correlation between pupil decentration and visual acuities (P > .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.
Hauth, Lothar; Kerstens, Jeroen; Yperzeele, Laetitia; Eyskens, François; Parizel, Paul M; Willekens, Barbara
2018-01-01
A 16-year-old male presented with episodic headaches and a brain magnetic resonance imaging (MRI) that showed multifocal punctate to patchy white matter lesions. The diagnosis of Fabry disease (FD) was suggested upon the finding of significantly reduced plasma alpha-galactosidase A activity (0.62 µmol/L or 13% of normal; normal range ≥ 1.65 μmol/L) and genetic investigation confirmed the presence of a hemizygous missense variant in the galactosidase alpha (GLA) gene (p.A143T). Baseline assessment of other systemic involvement showed only a discrete proteinuria. FD is a rare lysosomal storage disorder. Genetic screening studies have revealed over 600 variants in the GLA gene. The p.A143T variant is a genetic variant of unknown significance, with its associated phenotype ranging from classical FD to healthy unaffected patients. Some authors, however, deem this variant non-pathogenic. We describe the case of a 16-year-old male with multifocal white matter lesions on brain MRI, who was diagnosed with FD and carried this genetic variant. The causative p.A143T mutation can be associated with a more severe subclinical phenotype than has been reported to date. Furthermore, a diagnosis of FD should be considered when finding asymptomatic cerebral white matter lesions in a young patient.
[Chronic recurrent multifocal osteomyelitis of the mandible: report of three cases].
Paim, Luciana B; Liphaus, Bernadete Lourdes; Rocha, André C; Castellanos, Aura Ligia Z; Silva, Clovis Artur A
2003-01-01
To report three cases of chronic recurrent multifocal osteomyelitis of the mandible, an inflammatory disease affecting one or more bones with absence of isolated microorganisms in affected areas. The first case is a 13 year-old female presenting with pain and fever after dental treatment. The patient received antibiotic treatment for osteomyelitis, but developed progressive enlargement of the mandible and palmoplantar pustulosis. Bone scintigraphy showed intense and diffuse uptake in the mandible. The swelling decreased after indomethacin and hyperbaric oxygen therapy. Case 2 is a 9 year-old female patient with recurrent pain and edema of the right mandible for three years. The diagnosis of osteomyelitis was established and amoxicillin introduced. After three months, tomography showed diffuse mandible osteolysis. Indomethacin and hyperbaric oxygen therapy were introduced, however the patient presented a relapse and was treated with prednisone, rofecoxib and methotrexate. Patient 3, a 10 year-old male, had palmoplantar pustulosis and recurrent enlargement of the mandible. Tomography showed diffuse mandible osteolysis and scintigraphy revealed intense and diffuse uptake in the mandible. The patient was treated with prednisone. Rofecoxib was replaced after two relapses. Chronic recurrent multifocal osteomyelitis of the mandible is often associated with prolonged pain periods and periods of activity and remission of the inflammatory process. Its recognition is important to prevent the patient from being submitted to prolonged antibiotic therapy and unnecessary invasive procedures.
Nelson, Michelle; Salguero, Francisco J; Dean, Rachel E; Ngugi, Sarah A; Smither, Sophie J; Atkins, Timothy P; Lever, Mark S
2014-01-01
Glanders and melioidosis are caused by two distinct Burkholderia species and have generally been considered to have similar disease progression. While both of these pathogens are HHS/CDC Tier 1 agents, natural infection with both these pathogens is primarily through skin inoculation. The common marmoset (Callithrix jacchus) was used to compare disease following experimental subcutaneous challenge. Acute, lethal disease was observed in marmosets following challenge with between 26 and 1.2 × 108 cfu Burkholderia pseudomallei within 22–85 h. The reproducibility and progression of the disease were assessed following a challenge of 1 × 102 cfu of B. pseudomallei. Melioidosis was characterised by high levels of bacteraemia, focal microgranuloma progressing to non-necrotic multifocal solid lesions in the livers and spleens and multi-organ failure. Lethal disease was observed in 93% of animals challenged with Burkholderia mallei, occurring between 5 and 10.6 days. Following challenge with 1 × 102 cfu of B. mallei, glanders was characterised with lymphatic spread of the bacteria and non-necrotic, multifocal solid lesions progressing to a multifocal lesion with severe necrosis and pneumonia. The experimental results confirmed that the disease pathology and presentation is strikingly different between the two pathogens. The marmoset provides a model of the human syndrome for both diseases facilitating the development of medical countermeasures. PMID:25477002
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cotroneo, Antonio Raffaele; Iezzi, Roberto; Marano, Giuseppe
2007-06-15
Purpose. To report the 2-year results after hybrid (combined surgical-endovascular) therapy in patients with complex peripheral multifocal steno-obstructive vascular disease. Methods. From September 2001 through April 2003, 47 combined surgical-endovascular procedures were performed in a single session in 44 patients with peripheral occlusive artery disease. Although the common femoral artery is usually treated with open surgery, endoluminal procedures were performed upward in 23 patients (group A), distally in 18 patients (group B), and both upward and downward of the area treated with open surgery in 3 patients (group C). Patients underwent clinical assessment and color duplex ultrasonography examination at 1,more » 3, 6, 12, 18, and 24 months after the procedure. Results. The technical success rate was 100%. Two patients died, at 2 and 19 months after treatment, respectively, both from myocardial infarction. Primary and primary-assisted patency rates were 86.2% and 90.8% at 6 months and 79.1% and 86.1% at 24 months, respectively. Thirty-three patients remained free of symptoms, without any secondary interventions, which corresponded to a primary patency rate of 78.6% (33 of 42). Conclusion. Combined therapy simplifies and allows the one-step treatment of patients with complex peripheral multifocal steno-obstructive vascular disease that has indications for revascularization, and it provides excellent long-term patency rates.« less
Multifocal epithelial hyperplasia in a community in the Mayan area of Mexico.
González-Losa, Maria R; Suarez-Allén, Rosa E; Canul-Canche, Jaqueline; Conde-Ferráez, Laura; Eljure-Lopez, Nixma
2011-03-01
Multifocal epithelial hyperplasia is a pathology of the oral mucosa which has been reported in diverse ethnic groups. Human papillomavirus (HPV) types 13 and 32 DNA has been detected in these lesions. The aims of this paper are to describe the epidemiological and clinical characteristics of an outbreak in a rural community in the Mayan area of Mexico and to identify a possible route of transmission through saliva. A cross-sectional study was conducted in Chemax (Yucatan, Mexico). Clinical and epidemiological data were obtained through direct interviews. Samples of oral cells and saliva were taken. HPV 13 and 32 were identified by polymerase chain reaction using specific primers. A total of 57 patients were studied, of whom 79.1% were aged <15 years, 38.6% were male, and 61.3% were female. The duration of lesions ranged from one month to 50 years. Lesions were located on the lips, jugal mucosa, and more frequently, the tongue. HPV 13 was found in all the patients and HPV 32 in none. A total of 42 saliva samples were positive for HPV 13. Human papillomavirus type 13 is involved in multifocal epithelial hyperplasia among the Mexican Mayan population. The presence of HPV 13 in cells from saliva, combined with poor hygiene behaviors, may explain the familial distribution of the pathology. © 2011 The International Society of Dermatology.
Frahm, Jan-Michael; Pollefeys, Marc Andre Leon; Gallup, David Robert
2015-12-08
Methods of generating a three dimensional representation of an object in a reference plane from a depth map including distances from a reference point to pixels in an image of the object taken from a reference point. Weights are assigned to respective voxels in a three dimensional grid along rays extending from the reference point through the pixels in the image based on the distances in the depth map from the reference point to the respective pixels, and a height map including an array of height values in the reference plane is formed based on the assigned weights. An n-layer height map may be constructed by generating a probabilistic occupancy grid for the voxels and forming an n-dimensional height map comprising an array of layer height values in the reference plane based on the probabilistic occupancy grid.
SAND: an automated VLBI imaging and analysing pipeline - I. Stripping component trajectories
NASA Astrophysics Data System (ADS)
Zhang, M.; Collioud, A.; Charlot, P.
2018-02-01
We present our implementation of an automated very long baseline interferometry (VLBI) data-reduction pipeline that is dedicated to interferometric data imaging and analysis. The pipeline can handle massive VLBI data efficiently, which makes it an appropriate tool to investigate multi-epoch multiband VLBI data. Compared to traditional manual data reduction, our pipeline provides more objective results as less human interference is involved. The source extraction is carried out in the image plane, while deconvolution and model fitting are performed in both the image plane and the uv plane for parallel comparison. The output from the pipeline includes catalogues of CLEANed images and reconstructed models, polarization maps, proper motion estimates, core light curves and multiband spectra. We have developed a regression STRIP algorithm to automatically detect linear or non-linear patterns in the jet component trajectories. This algorithm offers an objective method to match jet components at different epochs and to determine their proper motions.
Intravitreal Bevacizumab vs.Combination Therapy for CNV Due to Other Than AMD
2014-01-13
Choroidal Neovascularization; Myopia; Punctate Inner Choroidopathy (PIC); Multifocal Choroiditis; Ocular Histoplasmosis Syndrome; Central Serous Chorioretinopathy (CSC); Angioid Streaks; Trauma, or Hereditary Eye Diseases
Giant slip lengths of a simple fluid at vibrating solid interfaces
NASA Astrophysics Data System (ADS)
Drezet, Aurélien; Siria, Alessandro; Huant, Serge; Chevrier, Joël
2010-04-01
It has been shown recently [A. Siria, A. Drezet, F. Marchi, F. Comin, S. Huant, and J. Chevrier, Phys. Rev. Lett. 102, 254503 (2009)] that in the plane-plane configuration, a mechanical resonator vibrating close to a rigid wall in a simple fluid can be overdamped to a frozen regime. Here, by solving analytically the Navier-Stokes equations with partial slip boundary conditions at the solid-fluid interface, we develop a theoretical approach justifying and extending these earlier findings. We show in particular that in the perfect-slip regime, the abovementioned results are, in the plane-plane configuration, very general and robust with respect to lever geometry considerations. We compare the results to those obtained previously for the sphere moving perpendicularly and close to a plane in a simple fluid and discuss in more details the differences concerning the dependence of the friction forces with the gap distance separating the moving object (i.e., plane or sphere) from the fixed plane. We show that the plane-plane geometry is more sensitive than the sphere-plane geometry for the measurement of slippage coefficients. Finally, we show that the submicron fluidic effect reported in the reference above, and discussed further in the present work, can have dramatic implications in the design of nanoelectromechanical systems.
Giant slip lengths of a simple fluid at vibrating solid interfaces.
Drezet, Aurélien; Siria, Alessandro; Huant, Serge; Chevrier, Joël
2010-04-01
It has been shown recently [A. Siria, A. Drezet, F. Marchi, F. Comin, S. Huant, and J. Chevrier, Phys. Rev. Lett. 102, 254503 (2009)] that in the plane-plane configuration, a mechanical resonator vibrating close to a rigid wall in a simple fluid can be overdamped to a frozen regime. Here, by solving analytically the Navier-Stokes equations with partial slip boundary conditions at the solid-fluid interface, we develop a theoretical approach justifying and extending these earlier findings. We show in particular that in the perfect-slip regime, the abovementioned results are, in the plane-plane configuration, very general and robust with respect to lever geometry considerations. We compare the results to those obtained previously for the sphere moving perpendicularly and close to a plane in a simple fluid and discuss in more details the differences concerning the dependence of the friction forces with the gap distance separating the moving object (i.e., plane or sphere) from the fixed plane. We show that the plane-plane geometry is more sensitive than the sphere-plane geometry for the measurement of slippage coefficients. Finally, we show that the submicron fluidic effect reported in the reference above, and discussed further in the present work, can have dramatic implications in the design of nanoelectromechanical systems.
Acquisition and replay systems for direct-to-digital holography and holovision
Thomas, Clarence E.; Hanson, Gregory R.
2003-02-25
Improvements to the acquisition and replay systems for direct-to-digital holography and holovision are described. A method of recording an off-axis hologram includes: splitting a laser beam into an object beam and a reference beam; reflecting the reference beam from a reference beam mirror; reflecting the object beam from an illumination beamsplitter; passing the object beam through an objective lens; reflecting the object beam from an object; focusing the reference beam and the object beam at a focal plane of a digital recorder to form an off-axis hologram; digitally recording the off-axis hologram; and transforming the off-axis hologram in accordance with a Fourier transform to obtain a set of results. A method of writing an off-axis hologram includes: passing a laser beam through a spatial light modulator; and focusing the laser beam at a focal plane of a photorefractive crystal to impose a holographic diffraction grating pattern on the photorefractive crystal. A method of replaying an off-axis hologram includes: illuminating a photorefractive crystal having a holographic diffraction grating with a replay beam.
Aldoss, Osamah; Patel, Sonali; Harris, Kyle; Divekar, Abhay
2015-06-01
The objective of the study is to compare radiation dose between the frontal and lateral planes in a biplane cardiac catheterization laboratory. Tube angulation progressively increases patient and operator radiation dose in single-plane cardiac catheterization laboratories. This retrospective study captured biplane radiation dose in a pediatric cardiac catheterization laboratory between April 2010 and January 2014. Raw and time-indexed fluoroscopic, cineangiographic and total (fluoroscopic + cineangiographic) air kerma (AK, mGy) and kerma area product (PKA, µGym(2)/Kg) for each plane were compared. Data for 716 patients were analyzed: 408 (56.98 %) were male, the median age was 4.86 years, and the median weight was 17.35 kg. Although median beam-on time (minutes) was 4.2 times greater in the frontal plane, there was no difference in raw median total PKA between the two planes. However, when indexed to beam-on time, the lateral plane had a higher median-indexed fluoroscopic (0.75 vs. 1.70), cineangiographic (16.03 vs. 24.92), and total (1.43 vs. 5.15) PKA (p < 0.0001). The median time-indexed total PKA in the lateral plane is 3.6 times the frontal plane. This is the first report showing that the lateral plane delivers a higher dose than the frontal plane per unit time. Operators should consciously reduce the lateral plane beam-on time and incorporate this practice in radiation reduction protocols.
TEACHERS' GUIDE. NINTH GRADE PLANE AND SOLID GEOMETRY FOR THE ACADEMICALLY TALENTED.
ERIC Educational Resources Information Center
HORN, R.A.
MATERIALS ARE INTENDED FOR A UNIFIED AND ACCELERATED PLANE AND SOLID GEOMETRY COURSE AND FOR EASY MODIFICATION AND ADAPTATION BY EXPERIENCED OR INEXPERIENCED TEACHER. TEXTBOOKS TO WHICH THE GUIDE HAS BEEN KEYED ARE LISTED. UNITS ARE GIVEN FOR BOTH SEMESTERS WITH TIME ALLOTMENTS RECOMMENDED. EACH UNIT IS SUBDIVIDED INTO TOPICS AND OBJECTIVES,…
Probing the smearing effect by a pointlike graviton in the plane-wave matrix model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Bum-Hoon; Nam, Siyoung; Shin, Hyeonjoon
2010-08-15
We investigate the interaction between a flat membrane and pointlike graviton in the plane-wave matrix model. The one-loop effective potential in the large-distance limit is computed and is shown to be of r{sup -3} type where r is the distance between two objects. This type of interaction has been interpreted as the one incorporating the smearing effect due to the configuration of a flat membrane in a plane-wave background. Our results support this interpretation and provide more evidence about it.
Laser-Induced Damage to Thin Film Dielectric Coatings.
1980-10-01
magnify and reimage the laser spot in the diagnostic Path B. Location [5] (see Figure (9)) is the equi- valent focal plane in Path B to that in Path A at...the thin film sample, (3] . The object distance is between the focal plane and the lens at [6) and the image distance is betv en the lens [6] and the...the equivalent focal plane in the diagnostic path and positioned so that the peak of the beam spatial profile falls on the pinhole. The diameter of the
NASA Technical Reports Server (NTRS)
Olczak, Eugene G. (Inventor)
2011-01-01
An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.
Detection and Classification of Pole-Like Objects from Mobile Mapping Data
NASA Astrophysics Data System (ADS)
Fukano, K.; Masuda, H.
2015-08-01
Laser scanners on a vehicle-based mobile mapping system can capture 3D point-clouds of roads and roadside objects. Since roadside objects have to be maintained periodically, their 3D models are useful for planning maintenance tasks. In our previous work, we proposed a method for detecting cylindrical poles and planar plates in a point-cloud. However, it is often required to further classify pole-like objects into utility poles, streetlights, traffic signals and signs, which are managed by different organizations. In addition, our previous method may fail to extract low pole-like objects, which are often observed in urban residential areas. In this paper, we propose new methods for extracting and classifying pole-like objects. In our method, we robustly extract a wide variety of poles by converting point-clouds into wireframe models and calculating cross-sections between wireframe models and horizontal cutting planes. For classifying pole-like objects, we subdivide a pole-like object into five subsets by extracting poles and planes, and calculate feature values of each subset. Then we apply a supervised machine learning method using feature variables of subsets. In our experiments, our method could achieve excellent results for detection and classification of pole-like objects.
Extended linear detection range for optical tweezers using image-plane detection scheme
NASA Astrophysics Data System (ADS)
Hajizadeh, Faegheh; Masoumeh Mousavi, S.; Khaksar, Zeinab S.; Reihani, S. Nader S.
2014-10-01
Ability to measure pico- and femto-Newton range forces using optical tweezers (OT) strongly relies on the sensitivity of its detection system. We show that the commonly used back-focal-plane detection method provides a linear response range which is shorter than that of the restoring force of OT for large beads. This limits measurable force range of OT. We show, both theoretically and experimentally, that utilizing a second laser beam for tracking could solve the problem. We also propose a new detection scheme in which the quadrant photodiode is positioned at the plane optically conjugate to the object plane (image plane). This method solves the problem without need for a second laser beam for the bead sizes that are commonly used in force spectroscopy applications of OT, such as biopolymer stretching.
Dhafiri, Yousef; Al Rubaie, Khalid; Kirat, Omar; May, William N; Nguyen, Quan D; Kozak, Igor
2017-01-01
The purpose of this study is to describe an association of unilateral multifocal choroiditis (MFC), retinal vasculitis, optic neuropathy, and bilateral keratoconus in a young Saudi male. A 27-year-old male patient with stable bilateral keratoconus presented with a painless vision loss in his left eye. Ophthalmic examinations revealed multiple foci of idiopathic chorioretinitis, retinal vasculitis, and mild optic disc leakage on fluorescein angiography, all of which resolved on systemic therapy with mycophenolate mofetil and prednisone after 3 months. Systemic medication was stopped after 8 months. One year after presentation, patient's visual acuity has improved and remained stable. Systemic immunomodulatory therapy can be effective in managing and leading to resolution of MFC, retinal vasculitis, and optic disc leak in young patients.
Multifocal lenses in coral reef fishes.
Karpestam, Björn; Gustafsson, Jonas; Shashar, Nadav; Katzir, Gadi; Kröger, Ronald H H
2007-08-01
The optical properties of crystalline lenses were studied in eleven species of coral reef fish from the Red Sea in Eilat, Israel. Three species each of diurnal planktivores, nocturnal planktivores and diurnal herbivores constituted three groups of animals with little within-group variability. In addition we studied two predators, which differed with respect to body size, prey preference, hunting method and diel activity period. All species studied have multifocal lenses. There were statistically significant differences in the optical properties of the lenses between the first three groups and between the predatory species. The properties of the lenses correlate well with known complements of visual pigments and feeding habits. Lenticular zones focusing ultraviolet light were found in two diurnal planktivores. The optical properties of the lens seem to be specifically adapted to the visual needs of each species.
Digitally switchable multi-focal lens using freeform optics.
Wang, Xuan; Qin, Yi; Hua, Hong; Lee, Yun-Han; Wu, Shin-Tson
2018-04-16
Optical technologies offering electrically tunable optical power have found a broad range of applications, from head-mounted displays for virtual and augmented reality applications to microscopy. In this paper, we present a novel design and prototype of a digitally switchable multi-focal lens (MFL) that offers the capability of rapidly switching the optical power of the system among multiple foci. It consists of a freeform singlet and a customized programmable optical shutter array (POSA). Time-multiplexed multiple foci can be obtained by electrically controlling the POSA to switch the light path through different segments of the freeform singlet rapidly. While this method can be applied to a broad range of imaging and display systems, we experimentally demonstrate a proof-of-concept prototype for a multi-foci imaging system.
NASA Astrophysics Data System (ADS)
Ellsworth-Bowers, Timothy P.
The Milky Way Galaxy serves as a vast laboratory for studying the dynamics and evolution of the dense interstellar medium and the processes of and surrounding massive star formation. From our vantage point within the Galactic plane, however, it has been extremely difficult to construct a coherent picture of Galactic structure; we cannot see the forest for the trees. The principal difficulties in studying the structure of the Galactic disk have been obscuration by the ubiquitous dust and molecular gas and confusion between objects along a line of sight. Recent technological advances have led to large-scale blind surveys of the Galactic plane at (sub-)millimeter wavelengths, where Galactic dust is generally optically thin, and have opened a new avenue for studying the forest. The Bolocam Galactic Plane Survey (BGPS) observed over 190 deg 2 of the Galactic plane in dust continuum emission near lambda = 1.1 mm, producing a catalog of over 8,000 dense molecular cloud structures across a wide swath of the Galactic disk. Deriving the spatial distribution and physical properties of these objects requires knowledge of distance, a component lacking in the data themselves. This thesis presents a generalized Bayesian probabilistic distance estimation method for dense molecular cloud structures, and demonstrates it with the BGPS data set. Distance probability density functions (DPDFs) are computed from kinematic distance likelihoods (which may be double- peaked for objects in the inner Galaxy) and an expandable suite of prior information to produce a comprehensive tally of our knowledge (and ignorance) of the distances to dense molecular cloud structures. As part of the DPDF formalism, this thesis derives several prior DPDFs for resolving the kinematic distance ambiguity in the inner Galaxy. From the collection of posterior DPDFs, a set of objects with well-constrained distance estimates is produced for deriving Galactic structure and the physical properties of dense molecular cloud structures. This distance catalog of 1,802 objects across the Galactic plane represents the first large-scale analysis of clump-scale objects in a variety of Galactic environments. The Galactocentric positions of these objects begin to trace out the spiral structure of the Milky Way, and suggest that dense molecular gas settles nearer the Galactic midplane than tracers of less-dense gas such as CO. Physical properties computed from the DPDFs reveal that BGPS objects trace a continuum of scales within giant molecular clouds, and extend the scaling relationships known as Larson's Laws to lower-mass substructures. The results presented here represent the first step on the road to seeing the molecular content of the Milky Way as a forest rather than individual nearby trees.
Gerbich, Therese M.; Rana, Kishan; Suzuki, Aussie; Schaefer, Kristina N.; Heppert, Jennifer K.; Boothby, Thomas C.; Allbritton, Nancy L.; Gladfelter, Amy S.; Maddox, Amy S.
2018-01-01
Fluorescence microscopy is a powerful approach for studying subcellular dynamics at high spatiotemporal resolution; however, conventional fluorescence microscopy techniques are light-intensive and introduce unnecessary photodamage. Light-sheet fluorescence microscopy (LSFM) mitigates these problems by selectively illuminating the focal plane of the detection objective by using orthogonal excitation. Orthogonal excitation requires geometries that physically limit the detection objective numerical aperture (NA), thereby limiting both light-gathering efficiency (brightness) and native spatial resolution. We present a novel live-cell LSFM method, lateral interference tilted excitation (LITE), in which a tilted light sheet illuminates the detection objective focal plane without a sterically limiting illumination scheme. LITE is thus compatible with any detection objective, including oil immersion, without an upper NA limit. LITE combines the low photodamage of LSFM with high resolution, high brightness, and coverslip-based objectives. We demonstrate the utility of LITE for imaging animal, fungal, and plant model organisms over many hours at high spatiotemporal resolution. PMID:29490939
Tobin, Jr., Kenneth W.; Bingham, Philip R.; Hawari, Ayman I.
2012-11-06
An imaging system employing a coded aperture mask having multiple pinholes is provided. The coded aperture mask is placed at a radiation source to pass the radiation through. The radiation impinges on, and passes through an object, which alters the radiation by absorption and/or scattering. Upon passing through the object, the radiation is detected at a detector plane to form an encoded image, which includes information on the absorption and/or scattering caused by the material and structural attributes of the object. The encoded image is decoded to provide a reconstructed image of the object. Because the coded aperture mask includes multiple pinholes, the radiation intensity is greater than a comparable system employing a single pinhole, thereby enabling a higher resolution. Further, the decoding of the encoded image can be performed to generate multiple images of the object at different distances from the detector plane. Methods and programs for operating the imaging system are also disclosed.
NASA Astrophysics Data System (ADS)
Chen, Ying-Tung; Lin, Hsing-Wen; Holman, Matthew J.; Payne, Matthew John; Fraser, Wesley Cristopher; Lacerda, Pedro; Ip, Wing-Huen; Pan-STARRS 1 Builders
2016-10-01
The origin of high inclination objects beyond Jupiter, including trans-Neptunian objects (TNOs) and Centaurs, remains uncertain. We report the discovery of a retrograde TNO, which we nickname "Niku", detected by the Pan-STARRS 1 Outer Solar System Survey. The numerical integrations show that the orbital dynamics of Niku are very similar to those of 2008 KV42 (Drac), with a half-life of ~ 500 Myr and analogous orbital evolution. Comparing similar high inclination members announced by the Minor-Planet Center (q > 10 AU, a < 100 AU and i > 60), we find these objects exhibit a surprising clustering of ascending node, populating a common orbital plane. The statistical significance of 3.8-sigma suggests it is unlikely to be coincidental. An unknown mechanism is required to explain the observed clustering. This discovery may provide a pathway to investigating a possible reservoir of high-inclination objects.
Progressive Multifocal Leukoencephalopathy
... is harmless except among those with lowered immune defenses. The disease is rare and occurs in patients ... is harmless except among those with lowered immune defenses. The disease is rare and occurs in patients ...
... immunoglobulin (IVIg) or immunosuppressive therapy with cyclophosphamide. Prognosis Improvement in muscle strength usually begins within 3 to ... of slow progression over many years. x Prognosis Improvement in muscle strength usually begins within 3 to ...
Vectorial point spread function and optical transfer function in oblique plane imaging.
Kim, Jeongmin; Li, Tongcang; Wang, Yuan; Zhang, Xiang
2014-05-05
Oblique plane imaging, using remote focusing with a tilted mirror, enables direct two-dimensional (2D) imaging of any inclined plane of interest in three-dimensional (3D) specimens. It can image real-time dynamics of a living sample that changes rapidly or evolves its structure along arbitrary orientations. It also allows direct observations of any tilted target plane in an object of which orientational information is inaccessible during sample preparation. In this work, we study the optical resolution of this innovative wide-field imaging method. Using the vectorial diffraction theory, we formulate the vectorial point spread function (PSF) of direct oblique plane imaging. The anisotropic lateral resolving power caused by light clipping from the tilted mirror is theoretically analyzed for all oblique angles. We show that the 2D PSF in oblique plane imaging is conceptually different from the inclined 2D slice of the 3D PSF in conventional lateral imaging. Vectorial optical transfer function (OTF) of oblique plane imaging is also calculated by the fast Fourier transform (FFT) method to study effects of oblique angles on frequency responses.
THE BOLOCAM GALACTIC PLANE SURVEY. VIII. A MID-INFRARED KINEMATIC DISTANCE DISCRIMINATION METHOD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellsworth-Bowers, Timothy P.; Glenn, Jason; Battersby, Cara
2013-06-10
We present a new distance estimation method for dust-continuum-identified molecular cloud clumps. Recent (sub-)millimeter Galactic plane surveys have cataloged tens of thousands of these objects, plausible precursors to stellar clusters, but detailed study of their physical properties requires robust distance determinations. We derive Bayesian distance probability density functions (DPDFs) for 770 objects from the Bolocam Galactic Plane Survey in the Galactic longitude range 7. Degree-Sign 5 {<=} l {<=} 65 Degree-Sign . The DPDF formalism is based on kinematic distances, and uses any number of external data sets to place prior distance probabilities to resolve the kinematic distance ambiguity (KDA)more » for objects in the inner Galaxy. We present here priors related to the mid-infrared absorption of dust in dense molecular regions and the distribution of molecular gas in the Galactic disk. By assuming a numerical model of Galactic mid-infrared emission and simple radiative transfer, we match the morphology of (sub-)millimeter thermal dust emission with mid-infrared absorption to compute a prior DPDF for distance discrimination. Selecting objects first from (sub-)millimeter source catalogs avoids a bias towards the darkest infrared dark clouds (IRDCs) and extends the range of heliocentric distance probed by mid-infrared extinction and includes lower-contrast sources. We derive well-constrained KDA resolutions for 618 molecular cloud clumps, with approximately 15% placed at or beyond the tangent distance. Objects with mid-infrared contrast sufficient to be cataloged as IRDCs are generally placed at the near kinematic distance. Distance comparisons with Galactic Ring Survey KDA resolutions yield a 92% agreement. A face-on view of the Milky Way using resolved distances reveals sections of the Sagittarius and Scutum-Centaurus Arms. This KDA-resolution method for large catalogs of sources through the combination of (sub-)millimeter and mid-infrared observations of molecular cloud clumps is generally applicable to other dust-continuum Galactic plane surveys.« less
Thin Planes of Satellites in ΛCDM are not kinematically coherent
NASA Astrophysics Data System (ADS)
Buck, Tobias; Dutton, Aaron A.; Macciò, Andrea V.
2017-03-01
Recently it has been shown by Ibata et al. (2013) that a large fraction of the dwarf satellite galaxies found in the PAndAS survey (McConnachie et al. 2009) and orbiting the Andromeda galaxy are surprisingly aligned in a thin, extended, and kinematically coherent planar structure. The presence of such a structure seems to challenge the current Cold Dark Matter paradigm of structure formation (Ibata et al. 2014, Pawlowski et al. 2014), which predicts a more uniform distribution of satellites around central objects. We show that it is possible to obtain a thin, extended, rotating plane of satellites resembling the one in Andromeda in cosmological collisionless simulations based on this model. Our new 21 high-resolution simulations (see Buck et al. 2015) show a correlation between the formation time of the dark matter halo and the thickness of the plane of satellites. Our simulations have a high incidence of satellite planes as thin, extended, and as rich as the one in Andromeda and with a very coherent kinematic structure when we select early forming haloes. By tracking the formation of the satellites in the plane we show that they have mainly been accreted onto the main object along thin dark matter filaments at high redshift (Dekel et al. 2009, Libeskind et al. 2009, 2011). Our results show that the presence of a thin, extended, rotating plane of satellites is not a challenge for the Cold Dark Matter paradigm, but actually supports one of the predictions of this paradigm related to the presence of filaments of dark matter around galaxies at high redshift.
Jayaprasad, Sandhaya; Subramaniyan, Radhakrishnan; Devgan, Shalini
2016-01-01
Background: Warts are benign proliferations of skin and mucosa caused by the human papillomavirus (HPV). Plane warts are caused by HPV types 3, 10, 28, and 41, occurring mostly in children and young adults. Among the treatment modalities, topical application of trichloroacetic acid (TCA) is age old. Potassium hydroxide (KOH) has a keratolytic effect on virus-infected cells. It is less irritating, less painful, less scar forming, and can be safely used in children too. Hence, it could be a better topical agent in the treatment of plane warts. Aims and Objectives: To compare the safety and efficacy of topical 10% KOH with 30% TCA in the treatment of plane warts. Materials and Methods: Sixty consecutive patients with plane warts were randomly assigned into two arms of thirty patients each; arm A received topical 10% KOH and arm B received topical 30% TCA as a once weekly application until the complete clearance of warts or a maximum period of 12 weeks. Results: Statistically no significant difference (P = 0.07) was found between the objective therapeutic response to 10% KOH and 30% TCA at the end of study (12 weeks). However, subjective response to 10% KOH was better and statistically significant (P = 0.03). There was no recurrence of warts seen on follow-up for 3 months of complete responders in both the arms. Conclusion: 10% KOH is found to be equally effective in the treatment of plane warts compared to 30% TCA with the advantage of faster onset of action and tendency of completely clearing warts with fewer side effects. PMID:27904181
A method of plane geometry primitive presentation
NASA Astrophysics Data System (ADS)
Jiao, Anbo; Luo, Haibo; Chang, Zheng; Hui, Bin
2014-11-01
Point feature and line feature are basic elements in object feature sets, and they play an important role in object matching and recognition. On one hand, point feature is sensitive to noise; on the other hand, there are usually a huge number of point features in an image, which makes it complex for matching. Line feature includes straight line segment and curve. One difficulty in straight line segment matching is the uncertainty of endpoint location, the other is straight line segment fracture problem or short straight line segments joined to form long straight line segment. While for the curve, in addition to the above problems, there is another difficulty in how to quantitatively describe the shape difference between curves. Due to the problems of point feature and line feature, the robustness and accuracy of target description will be affected; in this case, a method of plane geometry primitive presentation is proposed to describe the significant structure of an object. Firstly, two types of primitives are constructed, they are intersecting line primitive and blob primitive. Secondly, a line segment detector (LSD) is applied to detect line segment, and then intersecting line primitive is extracted. Finally, robustness and accuracy of the plane geometry primitive presentation method is studied. This method has a good ability to obtain structural information of the object, even if there is rotation or scale change of the object in the image. Experimental results verify the robustness and accuracy of this method.
Ruffini, Giulio; Fox, Michael D; Ripolles, Oscar; Miranda, Pedro Cavaleiro; Pascual-Leone, Alvaro
2014-04-01
Recently, multifocal transcranial current stimulation (tCS) devices using several relatively small electrodes have been used to achieve more focal stimulation of specific cortical targets. However, it is becoming increasingly recognized that many behavioral manifestations of neurological and psychiatric disease are not solely the result of abnormality in one isolated brain region but represent alterations in brain networks. In this paper we describe a method for optimizing the configuration of multifocal tCS for stimulation of brain networks, represented by spatially extended cortical targets. We show how, based on fMRI, PET, EEG or other data specifying a target map on the cortical surface for excitatory, inhibitory or neutral stimulation and a constraint on the maximal number of electrodes, a solution can be produced with the optimal currents and locations of the electrodes. The method described here relies on a fast calculation of multifocal tCS electric fields (including components normal and tangential to the cortical boundaries) using a five layer finite element model of a realistic head. Based on the hypothesis that the effects of current stimulation are to first order due to the interaction of electric fields with populations of elongated cortical neurons, it is argued that the optimization problem for tCS stimulation can be defined in terms of the component of the electric field normal to the cortical surface. Solutions are found using constrained least squares to optimize current intensities, while electrode number and their locations are selected using a genetic algorithm. For direct current tCS (tDCS) applications, we provide some examples of this technique using an available tCS system providing 8 small Ag/AgCl stimulation electrodes. We demonstrate the approach both for localized and spatially extended targets defined using rs-fcMRI and PET data, with clinical applications in stroke and depression. Finally, we extend these ideas to more general stimulation protocols, such as alternating current tCS (tACS). Copyright © 2013 Elsevier Inc. All rights reserved.
Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P
2012-03-01
To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
SU-G-BRA-03: PCA Based Imaging Angle Optimization for 2D Cine MRI Based Radiotherapy Guidance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, T; Yue, N; Jabbour, S
2016-06-15
Purpose: To develop an imaging angle optimization methodology for orthogonal 2D cine MRI based radiotherapy guidance using Principal Component Analysis (PCA) of target motion retrieved from 4DCT. Methods: We retrospectively analyzed 4DCT of 6 patients with lung tumor. A radiation oncologist manually contoured the target volume at the maximal inhalation phase of the respiratory cycle. An object constrained deformable image registration (DIR) method has been developed to track the target motion along the respiration at ten phases. The motion of the center of the target mass has been analyzed using the PCA to find out the principal motion components thatmore » were uncorrelated with each other. Two orthogonal image planes for cineMRI have been determined using this method to minimize the through plane motion during MRI based radiotherapy guidance. Results: 3D target respiratory motion for all 6 patients has been efficiently retrieved from 4DCT. In this process, the object constrained DIR demonstrated satisfactory accuracy and efficiency to enable the automatic motion tracking for clinical application. The average motion amplitude in the AP, lateral, and longitudinal directions were 3.6mm (min: 1.6mm, max: 5.6mm), 1.7mm (min: 0.6mm, max: 2.7mm), and 5.6mm (min: 1.8mm, max: 16.1mm), respectively. Based on PCA, the optimal orthogonal imaging planes were determined for cineMRI. The average angular difference between the PCA determined imaging planes and the traditional AP and lateral imaging planes were 47 and 31 degrees, respectively. After optimization, the average amplitude of through plane motion reduced from 3.6mm in AP images to 2.5mm (min:1.3mm, max:3.9mm); and from 1.7mm in lateral images to 0.6mm (min: 0.2mm, max:1.5mm), while the principal in plane motion amplitude increased from 5.6mm to 6.5mm (min: 2.8mm, max: 17mm). Conclusion: DIR and PCA can be used to optimize the orthogonal image planes of cineMRI to minimize the through plane motion during radiotherapy guidance.« less
In Situ alignment system for phase-shifting point-diffraction interferometry
Goldberg, Kenneth Alan; Naulleau, Patrick P.
2000-01-01
A device and method to facilitate the gross alignment of patterned object- and image-plane masks in optical systems such as the phase-shifting point diffraction interferometer are provided. When an array of similar pinholes or discreet mask fields is used, confusion can occur over the alignment of the focused beams within the field. Adding to the mask pattern a circumscribed or inscribed set of symbols that are identifiable in situ facilitates the unambiguous gross alignment of the object- and/or image-plane masks. Alternatively, a system of markings can be encoded directly into the window shape to accomplish this same task.
Three-dimensional broadband ground-plane cloak made of metamaterials
Ma, Hui Feng; Cui, Tie Jun
2010-01-01
Since invisibility cloaks were first suggested by transformation optics theory, there has been much work on the theoretical analysis and design of various types and a few experimental verifications at microwave and optical frequencies within two-dimensional limits. Here, we realize the first practical implementation of a fully 3D broadband and low-loss ground-plane cloak at microwave frequencies. The cloak, realized by drilling inhomogeneous holes in multi-layered dielectric plates, can conceal a 3D object located under a curved conducting plane from all viewing angles by imitating the reflection of a flat conducting plane. We also designed and realized, using non-resonant metamaterials, a high-gain lens antenna that can produce narrow-beam plane waves in the near-field region in a broad frequency band. The antenna constitutes the transmitter of the measurement system and is essential for the measurement of cloaking behaviour. PMID:20975696
Combinatorics associated with inflections and bitangents of plane quartics
NASA Astrophysics Data System (ADS)
Gizatullin, M. Kh
2013-08-01
After a preliminary survey and a description of some small Steiner systems from the standpoint of the theory of invariants of binary forms, we construct a binary Golay code (of length 24) using ideas from J. Grassmann's thesis of 1875. One of our tools is a pair of disjoint Fano planes. Another application of such pairs and properties of plane quartics is a construction of a new block design on 28 objects. This block design is a part of a dissection of the set of 288 Aronhold sevens. The dissection distributes the Aronhold sevens into 8 disjoint block designs of this type.
Corbett, Alexander D.; Burton, Rebecca A. B.; Bub, Gil; Salter, Patrick S.; Tuohy, Simon; Booth, Martin J.; Wilson, Tony
2014-01-01
Remote focussing microscopy allows sharp, in-focus images to be acquired at high speed from outside of the focal plane of an objective lens without any agitation of the specimen. However, without careful optical alignment, the advantages of remote focussing microscopy could be compromised by the introduction of depth-dependent scaling artifacts. To achieve an ideal alignment in a point-scanning remote focussing microscope, the lateral (XY) scan mirror pair must be imaged onto the back focal plane of both the reference and imaging objectives, in a telecentric arrangement. However, for many commercial objective lenses, it can be difficult to accurately locate the position of the back focal plane. This paper investigates the impact of this limitation on the fidelity of three-dimensional data sets of living cardiac tissue, specifically the introduction of distortions. These distortions limit the accuracy of sarcomere measurements taken directly from raw volumetric data. The origin of the distortion is first identified through simulation of a remote focussing microscope. Using a novel three-dimensional calibration specimen it was then possible to quantify experimentally the size of the distortion as a function of objective misalignment. Finally, by first approximating and then compensating the distortion in imaging data from whole heart rodent studies, the variance of sarcomere length (SL) measurements was reduced by almost 50%. PMID:25339910
Bone scintigraphy in children with cat scratch disease.
Donoso, Gilda; Paulsen, Cesar; Riquelme, Paulina; Lobo, Gabriel; Gutierrez, Daniela; Perez, Andrés; Jiménez, César
2013-12-01
The objective of this study was to evaluate the degree and incidence of bone involvement in patients with cat scratch disease. Patients admitted between 2004 and 2011 at the pediatric department for cat scratch disease and a positive serology for Bartonella henselae were identified. Only those having undergone a bone scintigraphy (BS) were included in this retrospective study. Sixteen girls and 8 boys with a mean age of 7 years were studied. Bone scintigraphy was positive in 6 (25%), but only 2 had bone pain. Axial involvement was present in all 6 patients, and appendicular lesions in 3 of them. Three patients had a BS control, with improvement or normalization after treatment with antibiotics. Bone involvement occurs infrequently in patients with cat scratch disease and is not always associated with specific signs. Cat scratch disease must be suspected in patients with fever of unknown origin presenting multifocal lesions on BS.
Pros and Cons of Focal Therapy for Localised Prostate Cancer
Mearini, Luigi; Porena, Massimo
2011-01-01
In prostate cancer, an interesting and intriguing option to overcome the risks of whole-gland treatment is focal therapy, with the aim of eradicating known cancer foci and reducing collateral damages to the structures essential for maintaining normal urinary and sexual function. Ablation of all known lesions would favorably alter the natural history of the cancer without impacting health-related quality of life and allows for safe retreatment with repeated focal therapy or whole-gland approaches if necessary. Our objective is to reassess the possibilities and criticisms of such procedure: the rationale for focal therapy and the enthusiasm come from the success of conservative approaches in treating other malignancies and in the high incidence of overtreatment introduced by prostate cancer screening programs. One of the challenges in applying such an approach to the treatment of prostate cancer is the multifocal nature of the disease and current difficulties in accurate tumor mapmaking. PMID:22110990
Genetics Home Reference: Majeed syndrome
... Al-Saad KK, Ijadi-Maghsoodi R, El-Shanti HI, Ferguson PJ. A splice site mutation confirms the ... gov/books/NBK1974/ Citation on PubMed El-Shanti HI, Ferguson PJ. Chronic recurrent multifocal osteomyelitis: a concise ...
Dyck, Peter J; Taylor, Bruce V; Davies, Jenny L; Mauermann, Michelle L; Litchy, William J; Klein, Christopher J; Dyck, P James B
2015-10-01
Intravenous immunoglobulin [IVIg], plasma exchange [PE], and corticosteroids are efficacious treatment in chronic inflammatory demyelinating polyneuropathy [CIDP]. IVIg is effective in multifocal motor neuropathy [MMN]. NIS, NIS-weakness, sum scores of raw amplitudes of motor fiber (CMAPs) amplitudes, and Dyck/Rankin score provided reliable measures to detect and scale abnormality and reflect change; they are therefore ideal for office management of response-based immunotherapy (R-IRx) of CIDP. Using efficacious R-IRx, a large early and late therapeutic response (≥ one-fourth were in remission or had recovered) was demonstrated in CIDP. In MMN only an early improvement with late non-significant worsening was observed. The difference in immunotherapy response supports a fundamental difference between CIDP (immune attack on Schwann cells and myelin) and MMN (attack on nodes of Ranvier and axons). © 2015 Wiley Periodicals, Inc.
Stenner, Markus; Müller, Klaus-Michael; Koopmann, Mario; Rudack, Claudia
2014-09-01
We report on a rare case of a laryngeal carcinoma arising in a multifocal pharyngolaryngeal oncocytic papillary cystadenoma (OPC). The disease of a 63-year-old man is well documented by computed and positron emission tomography, histology, and electron microscopy. We could show that an OPC can even develop in the pharynx. The coexistence of both tumors makes this a challenging diagnosis for pathologists. Treated by surgery and radiotherapy, both lesions dissolved. Based on the literature available, we discuss the theory that the laryngeal carcinoma might be the result of a true metaplasia facilitated by chronic irritation and recommend a regular follow-up for OPC too. As in benign oncocytic lesions, we could show that the detection of numerous mitochondria is a diagnostic indicator for malignant variants as well.
Stenner, Markus; Müller, Klaus-Michael; Koopmann, Mario; Rudack, Claudia
2014-01-01
Abstract We report on a rare case of a laryngeal carcinoma arising in a multifocal pharyngolaryngeal oncocytic papillary cystadenoma (OPC). The disease of a 63-year-old man is well documented by computed and positron emission tomography, histology, and electron microscopy. We could show that an OPC can even develop in the pharynx. The coexistence of both tumors makes this a challenging diagnosis for pathologists. Treated by surgery and radiotherapy, both lesions dissolved. Based on the literature available, we discuss the theory that the laryngeal carcinoma might be the result of a true metaplasia facilitated by chronic irritation and recommend a regular follow-up for OPC too. As in benign oncocytic lesions, we could show that the detection of numerous mitochondria is a diagnostic indicator for malignant variants as well. PMID:25211046
Ishii, Junko; Shishido-Hara, Yukiko; Kawamoto, Michi; Fujiwara, Satoru; Imai, Yukihiro; Nakamichi, Kazuo; Kohara, Nobuo
2018-04-27
A 37-year-old woman with systemic lupus erythematosus (SLE) presented with gait disturbance and cognitive dysfunction. Brain magnetic resonance imaging (MRI) revealed small, punctate, T2-/fluid-attenuated inversion recovery-hyperintense and T1-hypointense lesions without gadolinium enhancement, which is atypical for progressive multifocal leukoencephalopathy (PML). On a pathological examination of biopsied brain tissues, JC virus-infected cells were hardly detected via immunohistochemistry but were certainly detected via in situ hybridization, conclusively verifying the PML diagnosis. After tapering off the immunosuppressant and mefloquine administration, the MRI findings revealed gradual improvement, and she has been stable for over 18 months. A punctate MRI pattern is not specific to natalizumab-associated PML but may be a ubiquitous early sign useful for the early diagnosis of PML.
Bilateral Multifocal Hamartoma of the Chest Wall in an Infant
Yilmaz, Erdem; Erol, Oguz Bulent; Pekcan, Melih; Gundogdu, Gokcen; Bilgic, Bilge; Gun, Feryal; Yekeler, Ensar
2015-01-01
Summary Background Hamartoma of the thoracic wall is a rare benign tumor that occurs in infancy and can be mistaken for a malignancy due to its clinical and imaging features. Hamartomas are extrapleural soft tissue lesions that cause rib expansion and destruction and appear on imaging as cystic areas with fluid levels and calcification. They can cause scoliosis, pressure on the neighboring lung parenchyma and mediastinal displacement. While conservative treatment is recommended in asymptomatic cases, growing lesions require surgical excision. Case Report In this report, we present the imaging findings in a 3-month-old infant that presented with a firm swelling in the chest wall and was histopathologically confirmed to have a bilateral multifocal hamartoma. Conclusions Radiological imaging methods are important for accurate diagnosis of this very rare condition that can be confused with a malignancy. PMID:26082822
Fukami, Yuki; Okada, Hiroaki; Yoshida, Mari; Yamaguchi, Keiji
2017-08-31
A 78-year old woman who presented with akinetic mutism was admitted to our hospital. Brain MRI showed multifocal increased T 2 /FLAIR signal with extensive cortical-subcortical involvement. We suspected autoimmune encephalitis and the patient received methylprednisolone pulse. Her conscious level gradually recovered, but later relapsed again and presented with refractory status epilepticus. We treated her with intravenous immunoglobulin, plasma exchange and pulsed cyclophosphamide, with satisfactory response. A brain biopsy showed perivascular lymphocytic infiltrates and reactive gliosis. Anti-gamma aminobutyric acid (GABA) A receptor antibodies test came back to be positive after her recovery, and the diagnosis of anti-GABA A receptor antibody-positive encephalitis was made. This is a very rare case where brain biopsies were performed in a patient with anti-GABA A receptor antibody-positive encephalitis.
Magnetic resonance imaging characteristics in four dogs with central nervous system neosporosis.
Parzefall, Birgit; Driver, Colin J; Benigni, Livia; Davies, Emma
2014-01-01
Neosporosis is a polysystemic disease that can affect dogs of any age and can cause inflammation of the central nervous system. Antemortem diagnosis can be challenging, as clinical and conventional laboratory test findings are often nonspecific. A previous report described cerebellar lesions in brain MRI studies of seven dogs and proposed that these may be characteristic for central nervous system Neosporosis. The purpose of this retrospective study was to describe MRI characteristics in another group of dogs with confirmed central nervous system neosporosis and compare them with the previous report. The hospital's database was searched for dogs with confirmed central nervous system neosporosis and four observers recorded findings from each dog's MRI studies. A total of four dogs met inclusion criteria. Neurologic examination was indicative of a forebrain and cerebellar lesion in dog 2 and multifocal central nervous system disease in dogs 1, 3, and 4. Magnetic resonance imaging showed mild bilateral and symmetrical cerebellar atrophy in three of four dogs (dogs 2, 3, 4), intramedullary spinal cord changes in two dogs (dogs 3, 4) and a mesencephalic and metencephalic lesion in one dog (dog 2). Multifocal brain lesions were recognized in two dogs (dogs 1, 4) and were present in the thalamus, lentiform nucleus, centrum semiovale, internal capsule, brainstem and cortical gray matter of the frontal, parietal or temporal lobe. Findings indicated that central nervous system neosporosis may be characterized by multifocal MRI lesions as well as cerebellar involvement in dogs. © 2014 American College of Veterinary Radiology.
Multifocal microlens for bionic compound eye
NASA Astrophysics Data System (ADS)
Cao, Axiu; Wang, Jiazhou; Pang, Hui; Zhang, Man; Shi, Lifang; Deng, Qiling; Hu, Song
2017-10-01
Bionic compound eye optical element composed of multi-dimensional sub-eye microlenses plays an important role in miniaturizing the volume and weight of an imaging system. In this manuscript, we present a novel structure of the bionic compound eye with multiple focal lengths. By the division of the microlens into two concentric radial zones including the inner zone and the outer zone with independent radius, the sub-eye which is a multi-level micro-scale structure can be formed with multiple focal lengths. The imaging capability of the structure has been simulated. The results show that the optical information in different depths can be acquired by the structure. Meanwhile, the parameters including aperture and radius of the two zones, which have an influence on the imaging quality have been analyzed and discussed. With the increasing of the ratio of inner and outer aperture, the imaging quality of the inner zone is becoming better, and instead the outer zone will become worse. In addition, through controlling the radius of the inner and outer zone independently, the design of sub-eye with different focal lengths can be realized. With the difference between the radius of the inner and outer zone becoming larger, the imaging resolution of the sub-eye will decrease. Therefore, the optimization of the multifocal structure should be carried out according to the actual imaging quality demands. Meanwhile, this study can provide references for the further applications of multifocal microlens in bionic compound eye.
Barriers, motivators and enablers for dispensing multifocal contact lenses in Mumbai, India
Thite, Nilesh; Shah, Ukti; Mehta, Jasmin; Jurkus, Janice
2015-01-01
Purpose To understand the potential barriers, motivators and enablers in dispensing multifocal contact lenses (MFCL). Method Two focus group discussions were conducted to design questionnaires regarding the prescribing habits for multifocal contact lenses (MFCL). Questions on potential barriers and motivators were included. The questionnaires were distributed among 133 eye care practitioners across Mumbai, India. Practitioners fitting one or less patient per month with MFCL completed the survey describing potential barriers, while those who prescribed more MFCL's per month completed the survey describing enablers and motivators. Results Responses from 102 practitioners were received. Most common potential barriers in prescribing MFCL were increased chair time (75%), lack of readily available trials (69%) and limitation in power range (63%). Lack of awareness among patients (90%) was the most common barrier from patients’ outlook. Professional satisfaction (88%) and better business proposition (82%) were observed as main motivators while availability of the trials (84%) and correct patient selection (82%) were the major enablers. Graduate Optometrists felt dispensing MFCL did not offer a good business proposition (p = 0.02). Experienced practitioners were observed to be least motivated (p = 0.01) and believed that their patients found these lenses expensive (p = 0.02). Conclusion To enhance the MFCL practice, barriers like lack of awareness and limitations in power range must be addressed. Trial lens availability may motivate practitioners to prescribe MFCL. Further probing is required to understand lack of motivation among experienced practitioners. PMID:25563404
Power Profiles of Commercial Multifocal Soft Contact Lenses.
Kim, Eon; Bakaraju, Ravi C; Ehrmann, Klaus
2017-02-01
To evaluate the optical power profiles of commercially available soft multifocal contact lenses and compare their optical designs. The power profiles of 38 types of multifocal contact lenses-three lenses each-were measured in powers +6D, +3D, +1D, -1D, -3D, and -6D using NIMO TR1504 (Lambda-X, Belgium). All lenses were measured in phosphate buffered saline across 8 mm optic zone diameter. Refractive index of each lens material was measured using CLR 12-70 (Index Instruments, UK), which was used for converting measured power in the medium to in-air radial power profiles. Three basic types of power profiles were identified: center-near, center-distance, and concentric-zone ring-type designs. For most of the lens types, the relative plus with respect to prescription power was lower than the corresponding spectacle add. For some lens types, the measured power profiles were shifted by up to 1D across the power range relative to their labeled power. Most of the lenses were designed with noticeable amounts of spherical aberration. The sign and magnitude of spherical aberration can either be power dependent or consistent across the power range. Power profiles can vary widely between the different lens types; however, certain similarities were also observed between some of the center-near designs. For the more recently released lens types, there seems to be a trend emerging to reduce the relative plus with respect to prescription power, include negative spherical aberration, and keep the power profiles consistent across the power range.
[Biological characteristics and management of familial papillary thyroid carcinoma].
Zhao, Jing; Yu, Yang; Xia, Ting-ting; Liu, You-zhong; Wei, Song-feng; Zheng, Xiang-qian; Gao, Ming
2011-11-01
To analyze the clinical biological characteristics and investigate the managements of familial papillary thyroid carcinoma (FPTC). Clinical data of 36 patients with PTC from 15 families were retrospectively analyzed compared with 95 control cases taken randomly from the patients with sporadic PTC diagnosed and treated in Tianjin Cancer Hospital between January 2010 and August 2011. Of the 36 patients with FPTC, 15 (41.7%) were ≥45 years old, 12 (33.3%) had bilateral carcinoma, 20 (55.6%) were multifocality, 27 (75.0%) had neck lymph node metastases, 17 (47.2%) coexisted thyroid benign tumors. Of the 95 patients with SPTC, 60 (63.2%) were ≥45 years old, 12(12.6%)had bilateral carcinomas, 21 (22.1%) were multifocality, 51 (53.7%) had neck lymph node metastases, and 26(27.4%)coexisted thyroid benign tumors. Of the 36 patients with FPTC, 22 (61.1%) underwent total thyroidectomy and 14 (38.9%) with unilateral thyroidectomy plus isthmusectomy, 3 (8.3%) received unilateral or bilateral lateral neck dissection and central compartment neck dissection (CND), 7 (19.4%) received unilateral or bilateral posterolateral neck dissection and CND, 6 (16.6%) received posterolateral neck dissection and bilateral CND, and 20 (55.6%) received unilateral or bilateral CND. Age at disease presentation of FPTC was younger than that of SPTC. FPTC has higher rates of multifocality and bilateral carcinoma coexisting with thyroid benign tumor than those of SPTC. It necessary to take family history in detail and to evaluate diseases before operation.
Kumar, Nathella Pavan; Sridhar, Rathinam; Banurekha, Vaithilingam V.; Nair, Dina; Jawahar, Mohideen S.; Nutman, Thomas B.; Babu, Subash
2013-01-01
Background Th1 and Th17 responses are known to play an important role in immunity to pulmonary tuberculosis (PTB), although little is known about their role in extrapulmonary forms of tuberculosis (TB). Methods To identify the role of Th1, Th17, and Th22 cells in multi-focal TB lymphadenitis (TBL), we examined mycobacteria–specific immune responses in the whole blood of individuals with PTB (n = 20) and compared them with those with TBL (n = 25). Results Elevated frequencies of CD4+ T cells expressing IFN- γ, TNF-α, and IL-2 were present in individuals with TBL compared with those with PTB at baseline and in response to ESAT-6 and CFP-10. Similarly, increased frequencies of CD4+ T cells expressing IL-17A, IL-17F, and IFN-γ were also present in individuals with TBL at baseline and following ESAT-6 and CFP-10 stimulation although no significant difference in frequency of Th22 cells was observed. Finally, frequencies of Th1 (but not Th17) cells exhibited a significantly negative correlation with natural regulatory T cell frequencies at baseline. Conclusions Multi-focal TB lymphadenitis is therefore characterized by elevated frequencies of Th1 and Th17 cells, indicating that Th1 and Th17 responses in TB disease are probably correlates of disease severity rather than of protective immunity. PMID:23451159
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, Pushpender, E-mail: pugupta@wakehealth.edu; Allen, Brian C., E-mail: bcallen2@wakehealth.edu; Chen, Michael Y., E-mail: mchen@wakehealth.edu
Purpose: To evaluate renal function changes related to radiofrequency ablation (RFA) for the treatment of multifocal renal neoplasms. Methods: This is an institutional review board-approved, Health Insurance Portability and Accountability Act compliant retrospective study of all patients treated with computed tomography guided RFA for multifocal renal neoplasms at one institution. Fifty-seven subjects, mean age 70 (range 37-88) years, underwent RFA of 169 renal neoplasms (average size 2.0 cm). Subjects had between 2 and 8 (mean 2.96) neoplasms ablated. Estimated glomerular filtration rate (eGFR) was measured before and after RFA. Complications related to RFA were recorded. Results: eGFR decreased on averagemore » of 4.4 % per tumor treated and 6.7 % per ablation session (average 1.76 tumors treated per session). For subjects with the largest neoplasm measuring >3 cm, eGFR decreased an average of 14.5 % during the course of their treatment. If the largest neoplasm measured 2-3 cm, eGFR decreased an average of 7.7 %, and if the largest neoplasm measured <2 cm, eGFR decreased an average of 3.8 %. Subjects with reduced baseline renal function were more likely to have a greater decline in eGFR after RFA. There was a minor complication rate of 6.3 % (6 of 96 sessions), none of which required treatment, and a major complication rate of 4.2 % (4 of 96 sessions). Conclusion: RFA for the treatment of multifocal renal neoplasms results in mild decline of renal function.« less
Multifocal blue-on-yellow visual evoked potentials in early glaucoma.
Klistorner, Alexander; Graham, Stuart L; Martins, Alessandra; Grigg, John R; Arvind, Hemamalini; Kumar, Rajesh S; James, Andrew C; Billson, Francis A
2007-09-01
To determine the sensitivity and specificity of blue-on-yellow multifocal visual evoked potentials (mfVEPs) in early glaucoma. Cross-sectional study. Fifty patients with a confirmed diagnosis of early glaucoma and 60 normal participants. Black-and-white mfVEPs and blue-on-yellow mfVEPs were recorded using the Accumap version 2.0 (ObjectiVision Pty. Ltd., Sydney, Australia). All patients also underwent achromatic standard automated perimetry (SAP). Multifocal VEP amplitude and latency values in glaucoma patients were analyzed and compared with those of the normal controls. Based on the definition of visual field defect, in the group of glaucomatous eyes with SAP defects, amplitude of blue-on-yellow mfVEP was abnormal in all 64 cases (100% sensitivity), whereas black-and-white mfVEP missed 5 cases (92.2% sensitivity). Generally, larger scotomata were noted on blue-on-yellow mfVEP compared with black-and-white mfVEP for the same eyes. There was high topographic correspondence between SAP and amplitude of blue-on-yellow mfVEP and significant (P<0.0001) correlation between them (correlation coefficient, 0.73). Abnormal amplitude was detected in 3 of 60 eyes of control subjects (95% specificity). There was, however, no correlation between visual field defect and latency delay in glaucoma patients. Although there was a significant difference between averaged latency of control and glaucoma eyes, values considerably overlapped. The blue-on-yellow mfVEP is a sensitive and specific tool for detecting early glaucoma based on amplitude analysis.
Nelson, Michelle; Salguero, Francisco J; Dean, Rachel E; Ngugi, Sarah A; Smither, Sophie J; Atkins, Timothy P; Lever, Mark S
2014-12-01
Glanders and melioidosis are caused by two distinct Burkholderia species and have generally been considered to have similar disease progression. While both of these pathogens are HHS/CDC Tier 1 agents, natural infection with both these pathogens is primarily through skin inoculation. The common marmoset (Callithrix jacchus) was used to compare disease following experimental subcutaneous challenge. Acute, lethal disease was observed in marmosets following challenge with between 26 and 1.2 × 10(8) cfu Burkholderia pseudomallei within 22-85 h. The reproducibility and progression of the disease were assessed following a challenge of 1 × 10(2) cfu of B. pseudomallei. Melioidosis was characterised by high levels of bacteraemia, focal microgranuloma progressing to non-necrotic multifocal solid lesions in the livers and spleens and multi-organ failure. Lethal disease was observed in 93% of animals challenged with Burkholderia mallei, occurring between 5 and 10.6 days. Following challenge with 1 × 10(2) cfu of B. mallei, glanders was characterised with lymphatic spread of the bacteria and non-necrotic, multifocal solid lesions progressing to a multifocal lesion with severe necrosis and pneumonia. The experimental results confirmed that the disease pathology and presentation is strikingly different between the two pathogens. The marmoset provides a model of the human syndrome for both diseases facilitating the development of medical countermeasures. © 2014 Crown copyright. International Journal of Experimental Pathology © 2014 Company of the International Journal of Experimental Pathology (CIJEP).
Barriers, motivators and enablers for dispensing multifocal contact lenses in Mumbai, India.
Thite, Nilesh; Shah, Ukti; Mehta, Jasmin; Jurkus, Janice
2015-01-01
To understand the potential barriers, motivators and enablers in dispensing multifocal contact lenses (MFCL). Two focus group discussions were conducted to design questionnaires regarding the prescribing habits for multifocal contact lenses (MFCL). Questions on potential barriers and motivators were included. The questionnaires were distributed among 133 eye care practitioners across Mumbai, India. Practitioners fitting one or less patient per month with MFCL completed the survey describing potential barriers, while those who prescribed more MFCL's per month completed the survey describing enablers and motivators. Responses from 102 practitioners were received. Most common potential barriers in prescribing MFCL were increased chair time (75%), lack of readily available trials (69%) and limitation in power range (63%). Lack of awareness among patients (90%) was the most common barrier from patients' outlook. Professional satisfaction (88%) and better business proposition (82%) were observed as main motivators while availability of the trials (84%) and correct patient selection (82%) were the major enablers. Graduate Optometrists felt dispensing MFCL did not offer a good business proposition (p=0.02). Experienced practitioners were observed to be least motivated (p=0.01) and believed that their patients found these lenses expensive (p=0.02). To enhance the MFCL practice, barriers like lack of awareness and limitations in power range must be addressed. Trial lens availability may motivate practitioners to prescribe MFCL. Further probing is required to understand lack of motivation among experienced practitioners. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Hydrocephalus due to multiple ependymal malformations is caused by mutations in the MPDZ gene.
Saugier-Veber, Pascale; Marguet, Florent; Lecoquierre, François; Adle-Biassette, Homa; Guimiot, Fabien; Cipriani, Sara; Patrier, Sophie; Brasseur-Daudruy, Marie; Goldenberg, Alice; Layet, Valérie; Capri, Yline; Gérard, Marion; Frébourg, Thierry; Laquerrière, Annie
2017-05-01
Congenital hydrocephalus is considered as either acquired due to haemorrhage, infection or neoplasia or as of developmental nature and is divided into two subgroups, communicating and obstructive. Congenital hydrocephalus is either syndromic or non-syndromic, and in the latter no cause is found in more than half of the patients. In patients with isolated hydrocephalus, L1CAM mutations represent the most common aetiology. More recently, a founder mutation has also been reported in the MPDZ gene in foetuses presenting massive hydrocephalus, but the neuropathology remains unknown. We describe here three novel homozygous null mutations in the MPDZ gene in foetuses whose post-mortem examination has revealed a homogeneous phenotype characterized by multiple ependymal malformations along the aqueduct of Sylvius, the third and fourth ventricles as well as the central canal of the medulla, consisting in multifocal rosettes with immature cell accumulation in the vicinity of ependymal lining early detached from the ventricular zone. MPDZ also named MUPP1 is an essential component of tight junctions which are expressed from early brain development in the choroid plexuses and ependyma. Alterations in the formation of tight junctions within the ependyma very likely account for the lesions observed and highlight for the first time that primary multifocal ependymal malformations of the ventricular system is genetically determined in humans. Therefore, MPDZ sequencing should be performed when neuropathological examination reveals multifocal ependymal rosette formation within the aqueduct of Sylvius, of the third and fourth ventricles and of the central canal of the medulla.
Grandl, Susanne; Scherer, Kai; Sztrókay-Gaul, Anikó; Birnbacher, Lorenz; Willer, Konstantin; Chabior, Michael; Herzen, Julia; Mayr, Doris; Auweter, Sigrid D; Pfeiffer, Franz; Bamberg, Fabian; Hellerhoff, Karin
2015-12-01
Conventional X-ray attenuation-based contrast is inherently low for the soft-tissue components of the female breast. To overcome this limitation, we investigate the diagnostic merits arising from dark-field mammography by means of certain tumour structures enclosed within freshly dissected mastectomy samples. We performed grating-based absorption, absolute phase and dark-field mammography of three freshly dissected mastectomy samples containing bi- and multifocal carcinoma using a compact, laboratory Talbot-Lau interferometer. Preoperative in vivo imaging (digital mammography, ultrasound, MRI), postoperative histopathological analysis and ex vivo digital mammograms of all samples were acquired for the diagnostic verification of our results. In the diagnosis of multifocal tumour growth, dark-field mammography seems superior to standard breast imaging modalities, providing a better resolution of small, calcified tumour nodules, demarcation of tumour boundaries with desmoplastic stromal response and spiculated soft-tissue strands extending from an invasive ductal breast cancer. On the basis of selected cases, we demonstrate that dark-field mammography is capable of outperforming conventional mammographic imaging of tumour features in both calcified and non-calcified tumours. Presuming dose optimization, our results encourage further studies on larger patient cohorts to identify those patients that will benefit the most from this promising additional imaging modality. • X-ray dark-field mammography provides significantly improved visualization of tumour features • X-ray dark-field mammography is capable of outperforming conventional mammographic imaging • X-ray dark-field mammography provides imaging sensitivity towards highly dispersed calcium grains.
USDA-ARS?s Scientific Manuscript database
Objectives were to investigate effects of nutritional plane and Se supply during gestation on yield and nutrient composition of colostrum and milk in first parity ewes. Rambouillet ewe lambs (n = 84, age = 240 +/- 17 d, BW = 52.1 +/- 6.2 kg), were allocated to 6 treatments in a 2 x 3 factorial array...
USDA-ARS?s Scientific Manuscript database
Objectives were to investigate the effects of maternal Se supply and nutritional plane during gestation on offspring visceral tissues and indices of intestinal growth, vascularity, and function at 180 d of age. Rambouillet ewe lambs (n = 82, approximately 240 d of age; 52 ± 0.8 kg BW at breeding) we...
USDA-ARS?s Scientific Manuscript database
The objective was to determine whether previous plane of milk replacer nutrition (PON) influences the pathophysiological responses to a combined viral-bacterial respiratory challenge. Thirty Holstein calves (1 day of age) were assigned to treatments in a 2 x 3 factorial arrangement with preweaned PO...
A general purpose wideband optical spatial frequency spectrum analyzer
NASA Technical Reports Server (NTRS)
Ballard, G. S.; Mellor, F. A.
1972-01-01
The light scattered at various angles by a transparent media is studied. An example of these applications is the optical Fourier spectrum measurement resulting from various spatial frequencies which were recorded on a photographic emulsion. A method for obtaining these measurements consists of illuminating the test object with parallel monochromatic light. A stationary lens, placed in the resulting wavefield at a distance of one focal length from the object, will focus parallel waves emanating from the test object at a point lying in the focal plane of the lens. A light detector with a small filtering aperture is then used to measure the intensity variation of the light in the focal or transform plane of the lens. Such measurements require the use of a lens which is highly corrected for all of the common aberrations except chromatic aberration.
Back focal plane microscopic ellipsometer with internal reflection geometry
NASA Astrophysics Data System (ADS)
Otsuki, Soichi; Murase, Norio; Kano, Hiroshi
2013-05-01
A back focal plane (BFP) ellipsometer is presented to measure a thin film on a cover glass using an oil-immersion high-numerical-aperture objective lens. The internal reflection geometry lowers the pseudo Brewster angle (ϕB) to the range over which the light distribution is observed in BFP of the objective. A calculation based on Mueller matrix was developed to compute ellipsometric parameters from the intensity distribution on BFP. The center and radius of the partial reflection region below the critical angle were determined and used to define a polar coordinate on BFP. Harmonic components were computed from the intensities along the azimuth direction and transformed to ellipsometric parameters at multiple incident angles around ϕB. The refractive index and thickness of the film and the contributions of the objective effect were estimated at the same time by fitting.
The apparent size of three-dimensional objects and their silhouettes: a solid-superiority effect.
Walker, J T; Walker, M J
1988-01-01
A solid object looks larger than its outline or silhouette under many viewing conditions. This solid-superiority effect may result from the assimilation or confusion of visual contours within the projection of a three-dimensional object on the picture plane. An aspect of the Müller-Lyer illusion may also play a role.
Oblique reconstructions in tomosynthesis. II. Super-resolution
Acciavatti, Raymond J.; Maidment, Andrew D. A.
2013-01-01
Purpose: In tomosynthesis, super-resolution has been demonstrated using reconstruction planes parallel to the detector. Super-resolution allows for subpixel resolution relative to the detector. The purpose of this work is to develop an analytical model that generalizes super-resolution to oblique reconstruction planes. Methods: In a digital tomosynthesis system, a sinusoidal test object is modeled along oblique angles (i.e., “pitches”) relative to the plane of the detector in a 3D divergent-beam acquisition geometry. To investigate the potential for super-resolution, the input frequency is specified to be greater than the alias frequency of the detector. Reconstructions are evaluated in an oblique plane along the extent of the object using simple backprojection (SBP) and filtered backprojection (FBP). By comparing the amplitude of the reconstruction against the attenuation coefficient of the object at various frequencies, the modulation transfer function (MTF) is calculated to determine whether modulation is within detectable limits for super-resolution. For experimental validation of super-resolution, a goniometry stand was used to orient a bar pattern phantom along various pitches relative to the breast support in a commercial digital breast tomosynthesis system. Results: Using theoretical modeling, it is shown that a single projection image cannot resolve a sine input whose frequency exceeds the detector alias frequency. The high frequency input is correctly visualized in SBP or FBP reconstruction using a slice along the pitch of the object. The Fourier transform of this reconstructed slice is maximized at the input frequency as proof that the object is resolved. Consistent with the theoretical results, experimental images of a bar pattern phantom showed super-resolution in oblique reconstructions. At various pitches, the highest frequency with detectable modulation was determined by visual inspection of the bar patterns. The dependency of the highest detectable frequency on pitch followed the same trend as the analytical model. It was demonstrated that super-resolution is not achievable if the pitch of the object approaches 90°, corresponding to the case in which the test frequency is perpendicular to the breast support. Only low frequency objects are detectable at pitches close to 90°. Conclusions: This work provides a platform for investigating super-resolution in oblique reconstructions for tomosynthesis. In breast imaging, this study should have applications in visualizing microcalcifications and other subtle signs of cancer. PMID:24320445
Stereo-hologram in discrete depth of field (Conference Presentation)
NASA Astrophysics Data System (ADS)
Lee, Kwanghoon; Park, Min-Chul
2017-05-01
In holographic space, continuous object space can be divided as several discrete spaces satisfied each of same depth of field (DoF). In the environment of wearable device using holography, specially, this concept can be applied to macroscopy filed in contrast of the field of microscopy. Since the former has not need to high depth resolution because perceiving power of eye in human visual system, it can distinguish clearly among the objects in depth space, has lower than optical power of microscopic field. Therefore continuous but discrete depth of field (DDoF) for whole object space can present the number of planes included sampled space considered its DoF. Each DoF plane has to consider the occlusion among the object's areas in its region to show the occluded phenomenon inducing by the visual axis around the eye field of view. It makes natural scene in recognition process even though the combined discontinuous DoF regions are altered to the continuous object space. Thus DDoF pull out the advantages such as saving consuming time of the calculation process making the hologram and the reconstruction. This approach deals mainly the properties of several factors required in stereo hologram HMD such as stereoscopic DoF according to the convergence, least number of DDoFs planes in normal visual circumstance (within to 10,000mm), the efficiency of saving time for taking whole holographic process under the our method compared to the existing. Consequently this approach would be applied directly to the stereo-hologram HMD field to embody a real-time holographic imaging.
Fan filters, the 3-D Radon transform, and image sequence analysis.
Marzetta, T L
1994-01-01
This paper develops a theory for the application of fan filters to moving objects. In contrast to previous treatments of the subject based on the 3-D Fourier transform, simplicity and insight are achieved by using the 3-D Radon transform. With this point of view, the Radon transform decomposes the image sequence into a set of plane waves that are parameterized by a two-component slowness vector. Fan filtering is equivalent to a multiplication in the Radon transform domain by a slowness response function, followed by an inverse Radon transform. The plane wave representation of a moving object involves only a restricted set of slownesses such that the inner product of the plane wave slowness vector and the moving object velocity vector is equal to one. All of the complexity in the application of fan filters to image sequences results from the velocity-slowness mapping not being one-to-one; therefore, the filter response cannot be independently specified at all velocities. A key contribution of this paper is to elucidate both the power and the limitations of fan filtering in this new application. A potential application of 3-D fan filters is in the detection of moving targets in clutter and noise. For example, an appropriately designed fan filter can reject perfectly all moving objects whose speed, irrespective of heading, is less than a specified cut-off speed, with only minor attenuation of significantly faster objects. A simple geometric construction determines the response of the filter for speeds greater than the cut-off speed.
Farrokhi, Shawn; Voycheck, Carrie A.; Gustafson, Jonathan A.; Fitzgerald, G. Kelley; Tashman, Scott
2015-01-01
Objective The objective of this exploratory study was to evaluate tibiofemoral joint contact point excursions and velocities during downhill gait and assess the relationship between tibiofemoral joint contact mechanics with frontal-plane knee joint motion and lower extremity muscle weakness in patients with knee osteoarthritis (OA). Methods Dynamic stereo X-ray was used to quantify tibiofemoral joint contact mechanics and frontal-plane motion during the loading response phase of downhill gait in 11 patients with knee OA and 11 control volunteers. Quantitative testing of the quadriceps and the hip abductor muscles was also performed. Group differences in contact mechanics and frontal-plane motion excursions were compared using analysis of covariance with adjustments for body mass index. Differences in strength were compared using independent sample t-tests. Additionally, linear associations between contact mechanics with frontal-plane knee motion and muscle strength were evaluated using Pearson's correlation coefficients. Results Patients with knee OA demonstrated larger medial/lateral joint contact point excursions (p<0.02) and greater heel-strike joint contact point velocities (p<0.05) for the medial and lateral compartments compared to the control group. The peak medial/lateral joint contact point velocity of the medial compartment was also greater for patients with knee OA compared to their control counterparts (p=0.02). Additionally, patients with knee OA demonstrated significantly increased frontal-plane varus motion excursions (p<0.01) and greater quadriceps and hip abductor muscle weakness (p=0.03). In general, increased joint contact point excursions and velocities in patients with knee OA were linearly associated with greater frontal-plane varus motion excursions (p<0.04) but not with quadriceps or hip abductor strength. Conclusion Altered contact mechanics in patients with knee OA may be related to compromised frontal-plane joint stability but not with deficits in muscle strength. PMID:27030846
Guillon, Michel; Dumbleton, Kathy; Theodoratos, Panagiotis; Patel, Trisha; Karkkainen, Tom; Moody, Kurt
2018-05-01
Contact lens wearers of Asian descent may be predisposed to experience microtrauma of the ocular surface as a result a thinner post-lens tear film and higher eyelid tension, and these effects would be anticipated to be most marked in an older population. The objective of this study was to quantify the mechanical effects of the study contact lenses on the ocular surface in a population of presbyopic contact lens wearers of Asian descent. Twenty established presbyopic contact lens wearers (hydrogel n=5, none habitual wearers of etafilcon A lenses; silicone hydrogel n=15) of Asian descent were refitted with etafilcon A multifocal daily disposable contact lenses (1-DAY ACUVUE MOIST MULTIFOCAL) for a period of 1 month of daily lens wear. The habitual modalities of wear were 45% daily disposable and 55% planned replacement. Digital photographs of the upper lid margins, nasal and temporal conjunctiva, and superior cornea were taken after 6 hr of wear of the participants' habitual contact lenses, after 1 day without contact lens wear, and after 6 hr of wear of the study contact lenses at the end of the 1-month period. The photographs were masked according to study visit and the staining extent measured using proprietary software. Lid margin staining was significantly lower with the study contact lenses (2.0±1.0 mm) than with the participants' own contact lenses (3.2±3.0 mm) after 6 hr of wear, representing a mean staining decrease of 38% (P=0.010). Lid margin staining after 6 hr of wear of the study contact lenses was not different from that measured after 1 day without contact lenses (P=0.507). Limbal staining was also significantly less with the study contact lenses than with the participants' own contact lenses after 6 hr of wear (P=0.009). There was minimal upper corneal staining, and the degree was similar with the study and habitual lenses. Etafilcon A material, worn under a daily disposable modality, was shown to reduce upper lid margin and limbal staining in presbyopic contact lens wearers of Asian descent compared with the wearers' own contact lenses. Because of the high preponderance of dry eye amongst presbyopes, material selection is of importance and consideration should be given to the lens-ocular surface interaction.
Dumbleton, Kathy; Theodoratos, Panagiotis; Patel, Trisha; Karkkainen, Tom; Moody, Kurt
2018-01-01
Introduction: Contact lens wearers of Asian descent may be predisposed to experience microtrauma of the ocular surface as a result a thinner post-lens tear film and higher eyelid tension, and these effects would be anticipated to be most marked in an older population. The objective of this study was to quantify the mechanical effects of the study contact lenses on the ocular surface in a population of presbyopic contact lens wearers of Asian descent. Methods: Twenty established presbyopic contact lens wearers (hydrogel n=5, none habitual wearers of etafilcon A lenses; silicone hydrogel n=15) of Asian descent were refitted with etafilcon A multifocal daily disposable contact lenses (1-DAY ACUVUE MOIST MULTIFOCAL) for a period of 1 month of daily lens wear. The habitual modalities of wear were 45% daily disposable and 55% planned replacement. Digital photographs of the upper lid margins, nasal and temporal conjunctiva, and superior cornea were taken after 6 hr of wear of the participants' habitual contact lenses, after 1 day without contact lens wear, and after 6 hr of wear of the study contact lenses at the end of the 1-month period. The photographs were masked according to study visit and the staining extent measured using proprietary software. Results: Lid margin staining was significantly lower with the study contact lenses (2.0±1.0 mm2) than with the participants' own contact lenses (3.2±3.0 mm2) after 6 hr of wear, representing a mean staining decrease of 38% (P=0.010). Lid margin staining after 6 hr of wear of the study contact lenses was not different from that measured after 1 day without contact lenses (P=0.507). Limbal staining was also significantly less with the study contact lenses than with the participants' own contact lenses after 6 hr of wear (P=0.009). There was minimal upper corneal staining, and the degree was similar with the study and habitual lenses. Conclusions: Etafilcon A material, worn under a daily disposable modality, was shown to reduce upper lid margin and limbal staining in presbyopic contact lens wearers of Asian descent compared with the wearers' own contact lenses. Because of the high preponderance of dry eye amongst presbyopes, material selection is of importance and consideration should be given to the lens–ocular surface interaction. PMID:27755285
Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari
2014-02-01
Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.
Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima
2014-01-01
Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212
Tilia, Daniel; Munro, Anna; Chung, Jiyoon; Sha, Jennifer; Delaney, Shona; Kho, Danny; Thomas, Varghese; Ehrmann, Klaus; Bakaraju, Ravi Chandra
To compare the visual performance of prototype contact lenses which extend depth-of-focus (EDOF) by deliberate manipulation of multiple higher-order spherical aberration terms and a commercially-available center-near lens (AIR OPTIX Aqua Multifocal, AOMF). This was a prospective, cross-over, randomized, single-masked (participant), short-term clinical trial where 52 participants (age 45-70 years) were stratified as low, medium or high presbyopes and wore EDOF and AOMF on different days. Objective measures comprised high and low contrast visual acuity (HCVA/LCVA, logMAR), and contrast sensitivity (log units) at 6m; HCVA at 70cm, 50cm and 40cm and stereopsis (seconds of arc) at 40cm. HCVA at 70cm, 50cm and 40cm were measured as "comfortable acuity" rather than conventional resolution acuity. Subjective measures comprised clarity-of-vision and ghosting at distance, intermediate and near, overall vision satisfaction and ocular comfort (1-10 numeric rating scale) and lens purchase (yes/no response). Statistical analysis included repeated measures ANOVA, paired t-tests and McNemar's test. Significant differences between lens types were independent of strata (p≥0.119). EDOF was significantly better than AOMF for HCVA at 40cm (0.42±0.18 vs. 0.48±0.22, p=0.024), stereopsis (98±88 vs. 141±114, p<0.001), clarity-of-vision at intermediate (8.5±1.6 vs. 7.7±1.9, p=0.006) and near (7.3±2.5 vs. 6.2±2.5, p=0.005), lack-of-ghosting (p=0.012), overall vision satisfaction (7.5±1.7 vs. 6.4±2.2, p<0.001) and ocular comfort (9.0±1.0 vs. 8.3±1.7, p=0.002). Significantly more participants chose to only-purchase EDOF (33% vs. 6%, p=0.003).). There were no significant differences between lens types for any objective measure at 6m or clarity-of-vision at distance (p≥0.356). EDOF provides better intermediate and near vision performance in presbyopes than AOMF with no difference for distance vision during short-term wear. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Limited-angle tomography for analyzer-based phase-contrast X-ray imaging
Majidi, Keivan; Wernick, Miles N; Li, Jun; Muehleman, Carol; Brankov, Jovan G
2014-01-01
Multiple-Image Radiography (MIR) is an analyzer-based phase-contrast X-ray imaging method (ABI), which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume. PMID:24898008
Limited-angle tomography for analyzer-based phase-contrast x-ray imaging
NASA Astrophysics Data System (ADS)
Majidi, Keivan; Wernick, Miles N.; Li, Jun; Muehleman, Carol; Brankov, Jovan G.
2014-07-01
Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.
A Comparative Evaluation between Cheiloscopic Patterns and Terminal Planes in Primary Dentition
Vignesh, R; Rekha, C Vishnu; Annamalai, Sankar; Norouzi, Parisa; Sharmin, Ditto
2017-01-01
Objective: To assess the correlation between different cheiloscopic patterns with the terminal planes in deciduous dentition. Materials and Methods: Three hundred children who are 3–6 years old with complete primary dentition were recruited, and the pattern of molar terminal plane was recorded in the pro forma. Lip prints of these children were recorded with lipstick-cellophane method, and the middle 10 mm of lower lip was analyzed for the lip print pattern as suggested by Sivapathasundharam et al. The pattern was classified based on Tsuchihashi and Suzuki classification. Results: Type II (branched) pattern was the most predominant cheiloscopic pattern. The predominant patterns which related to the terminal planes were as follows: Type IV (reticular) and Type V (irregular) pattern for mesial step, Type IV (reticular) pattern for distal step, and Type I (complete vertical) pattern for flush terminal plane. No significant relationship was obtained on gender comparison. Conclusion: Lip prints can provide an alternative to dermatoglyphics to predict the terminal plane in primary dentition. Further studies with larger sample size are required to provide an insight into its significant correlations. PMID:29326500
USDA-ARS?s Scientific Manuscript database
Objectives were to investigate effects of nutritional plane and Se supply during gestation on visceral organ mass and intestinal growth and vascularization in ewes at parturition and during early lactation. Primiparous Rambouillet ewes (n = 84) were allocated to 2 × 3 × 2 factorial arrangement of tr...
Summary of Research 1997, Department of Aeronautics and Astronautics
1999-01-01
military space planes ; (2) stability and control of single and dual-spin spacecraft; and (3) near-Earth-object interception. The research has lead...rectilinear cascade wind tunnel. Second generation blading, having approximately half the solidity of the first- generation design, when operated at...Control of an Unmanned Aerial Vehicle for Precise Navigation in the Local Tangent Plane ," Master’s Thesis, Naval Postgraduate School, March 1997