Sample records for observations ct findings

  1. CT findings in ulcerative, granulomatous, and indeterminate colitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gore, R.M.; Marn, C.S.; Kirby, D.F.

    1984-08-01

    Eight patients with ulcerative colitis, three with colitis indeterminate, and 15 patients with Crohn disease were studied by computed tomography (CT) to establish CT criteria for each disorder in hopes of providing a new diagnostic perspective useful in the radiographic evaluation of inflammatory colitis. The CT findings in ulcerative colitis included thickening of the colon wall, which was characterized by inhomogeneous attenuation and a target appearance of the rectum, and proliferation of perirectal fat. Bowel wall thickening with homogeneous attenuation, fistula and abscess formation, and mesenteric abnormalities were observed in patients with Crohn colitis. Patients with colitis indeterminate showed colonicmore » changes on CT observed in both disorders. Initial experience suggests that CT can differentiate patients with well established ulcerative and Crohn colitis.« less

  2. Intramammary Findings on CT of the Chest – a Review of Normal Anatomy and Possible Findings

    PubMed Central

    Gossner, Johannes

    2016-01-01

    Summary Computed tomography (CT) is a frequently performed examination in women of all ages. In all thoracic CT examinations of the chest at least parts of the breasts are included. Therefore incidental breast pathology may be observed. It has been suggested that one out of 250 women undergoing chest CT will show a malignant incidental breast lesion. Given the high number of performed chest CT examinations, this contributes to a significant number of malignancies. In this review, after a brief discussion of the value of computed tomography in breast imaging, normal and pathologic findings are discussed to create awareness of this potential “black box” on chest CT. PMID:28058068

  3. Thoracic textilomas: CT findings*

    PubMed Central

    Machado, Dianne Melo; Zanetti, Gláucia; Araujo, Cesar Augusto; Nobre, Luiz Felipe; Meirelles, Gustavo de Souza Portes; Pereira e Silva, Jorge Luiz; Guimarães, Marcos Duarte; Escuissato, Dante Luiz; Souza, Arthur Soares; Hochhegger, Bruno; Marchiori, Edson

    2014-01-01

    OBJECTIVE: The aim of this study was to analyze chest CT scans of patients with thoracic textiloma. METHODS: This was a retrospective study of 16 patients (11 men and 5 women) with surgically confirmed thoracic textiloma. The chest CT scans of those patients were evaluated by two independent observers, and discordant results were resolved by consensus. RESULTS: The majority (62.5%) of the textilomas were caused by previous heart surgery. The most common symptoms were chest pain (in 68.75%) and cough (in 56.25%). In all cases, the main tomographic finding was a mass with regular contours and borders that were well-defined or partially defined. Half of the textilomas occurred in the right hemithorax and half occurred in the left. The majority (56.25%) were located in the lower third of the lung. The diameter of the mass was ≤ 10 cm in 10 cases (62.5%) and > 10 cm in the remaining 6 cases (37.5%). Most (81.25%) of the textilomas were heterogeneous in density, with signs of calcification, gas, radiopaque marker, or sponge-like material. Peripheral expansion of the mass was observed in 12 (92.3%) of the 13 patients in whom a contrast agent was used. Intraoperatively, pleural involvement was observed in 14 cases (87.5%) and pericardial involvement was observed in 2 (12.5%). CONCLUSIONS: It is important to recognize the main tomographic aspects of thoracic textilomas in order to include this possibility in the differential diagnosis of chest pain and cough in patients with a history of heart or thoracic surgery, thus promoting the early identification and treatment of this postoperative complication. PMID:25410842

  4. Serum metabolites associate with CT findings following TBI.

    PubMed

    Dickens, Alex Mountfort; Posti, Jussi P; Takala, Riikka Sk; Ala-Seppälä, Henna Maria; Mattila, Ismo; Coles, Jonathan Coles; Frantzén, Janek; Hutchinson, Peter John; Katila, Ari J; Kyllönen, Anna; Maanpää, Henna-Riikka; Newcombe, Virginia; Outtrim, Joanne; Tallus, Jussi; Carpenter, Keri; Menon, David; Hyotylainen, Tuulia; Tenovuo, Olli; Oresic, Matej

    2018-06-27

    There is a need to rapidly detect patients with traumatic brain injury (TBI) who require head computed tomography (CT). Given the energy crisis in the brain following TBI, we hypothesized that serum metabolomics would be a useful tool for developing a set of biomarkers to determine the need for CT and to distinguish between different types of injuries observed. Logistic regression models using metabolite data from the discovery cohort (n=144, Turku, Finland) were used to distinguish between patients with traumatic intracranial findings and negative findings on head CT. The resultant models were then tested in the validation cohort (n=66, Cambridge, UK). The levels of glial fibrillary acidic protein and ubiquitin C-terminal hydrolase-L1 were also quantified in the serum from the same patients. Despite there being significant differences in the protein biomarkers in patients with TBI, the model that determined the need for a CT scan validated poorly (AUC=0.64: Cambridge patients). However, using a combination of six metabolites (two amino acids, three sugar derivatives and one ketoacid) it was possible to discriminate patients with intracranial abnormalities on CT and patients with a normal CT (AUC=0.77 in Turku patients and AUC=0.73 in Cambridge patients). Furthermore, a combination of three metabolites could distinguish between diffuse brain injuries and mass lesions (AUC=0.87 in Turku patients and AUC=0.68 in Cambridge patients). This study identifies a set of validated serum polar metabolites, which associate with the need for a CT scan. Additionally, serum metabolites can also predict the nature of the brain injury. These metabolite markers may prevent unnecessary CT scans, thus reducing the cost of diagnostics and radiation load.

  5. Evaluation of Oral Anticoagulant-Associated Intracranial Parenchymal Hematomas Using CT Findings.

    PubMed

    Gökçe, E; Beyhan, M; Acu, B

    2015-06-01

    Intracranial hemorrhage (ICH) is one of the most serious and lethal complications of anticoagulants with a reported incidence of 5-18.5 %. Computed tomographic (CT) findings, should be carefully studied because early diagnosis and treatment of oral anticoagulant use-associated hematomas are vitally important. In the present study, CT findings of intraparenchymal hematomas associated with anticoagulant and antihypertensive use are presented. This study included 45 patients (25 men, 20 women) under anticoagulant (21 patients) or antihypertensive (24 patients) treatment who had brain CT examinations due to complaints and findings suggesting cerebrovascular disease during July 2010-October 2013 period. CT examinations were performed to determine hematoma volumes and presence of swirl sign, hematocrit effect, mid-line shift effect, and intraventricular extension. The patients were 40-89 years of age. In four cases, a total of 51 intraparenchymal hematomas (42 cerebral, 7 cerebellar and 2 brain stem) were detected in multiple foci. Hematoma volumes varied from 0.09 to 284.00 ml. Swirl sign was observed in 87.5 and 63.0 % of OAC-associated ICHs and non-OAC-associated ICHs, respectively. In addition, hematocrit effect was observed in 41.6 % of OAC-associated and in 3.7 % of non-OAC-associated ICHs. Volume increases were observed in all 19 hematomas where swirl sign was detected, and follow-up CT scanning was conducted. Mortality of OAC-associated ICHs was correlated with initial volumes of hematoma, mid-line shift amount, and intraventricular extension. Detection of hematocrit effect by CT scanning of intracranial hematomas should be cautionary in oral anticoagulant use, while detection of swirl sign should be suggestive of active hemorrhage.

  6. CT findings of acute cholecystitis and its complications.

    PubMed

    Shakespear, Jonathan S; Shaaban, Akram M; Rezvani, Maryam

    2010-06-01

    The purpose of this article is to describe and illustrate the CT findings of acute cholecystitis and its complications. CT findings suggesting acute cholecystitis should be interpreted with caution and should probably serve as justification for further investigation with abdominal ultrasound. CT has a relatively high negative predictive value, and acute cholecystitis is unlikely in the setting of a negative CT. Complications of acute cholecystitis have a characteristic CT appearance and include necrosis, perforation, abscess formation, intraluminal hemorrhage, and wall emphysema.

  7. CT Findings in People Who Were Environmentally Exposed to Asbestos in Korea.

    PubMed

    Lee, Eun Kyoung; Kim, Jeung Sook; Kim, Yookyung; Park, Jai Soung

    2015-12-01

    Asbestos related pleuropulmonary disease has been emerging health problem for recent years. It can cause variable clinical symptoms and radiological abnormalities. However, there has been no report for their characteristics in subjects who were environmentally exposed to asbestos. We reviewed the CT images of 35 people who were environmentally exposed to asbestos in Chungnam province, Korea. The study result showed high incidence of pleural plaque and pulmonary fibrosis on chest CT (94% and 77%, respectively). The common CT findings of lung parenchymal lesions were as follows: centrilobular opacities (94%), subpleural dot-like or branching opacities (80%), interlobular septal thickening (57%), intralobular interstitial thickening (46%), parenchymal bands (43%) and subpleural curvilinear line (29%). There were no significant differences in the prevalence of pulmonary fibrosis and pleural plaques according to sex, age and duration of exposure. In conclusion, pleural plaque and pulmonary fibrosis are common asbestos-related CT finding in the exposed people. Asbestos related lung parenchymal CT findings in the participants with environmental exposure show similar to those observed in the occupational exposure.

  8. Aortic valve calcification - a commonly observed but frequently ignored finding during CT scanning of the chest.

    PubMed

    Raju, Prashanth; Sallomi, David; George, Bindu; Patel, Hitesh; Patel, Nikhil; Lloyd, Guy

    2012-06-01

    To describe the frequency and severity of Aortic valve calcification (AVC) in an unselected cohort of patients undergoing chest CT scanning and to assess the frequency with which AVC was being reported in the radiology reports. Consecutive CT scan images of the chest and the radiological reports (December 2009 to May 2010) were reviewed at the district general hospital (DGH). AVC on CT scan was visually graded on a scale ranging from 0 to IV (0 = no calcification, IV = severe calcification). Total of 416 (232 male; 184 female) CT chest scans [Contrast enhanced 302 (72%), unenhanced 114 (28%)] were reviewed. Mean age was 70.55 ± 11.48 years. AVC in CT scans was identified in 95 of the 416 patients (22.83%). AVC classification was as follows: Grade I: 60 (63.15%), Grade II: 22 (23.15%), Grade III: 9 (9.47%), Grade IV: 4 (4.21%). Only one CT report mentioned AVC. Only 31 of 95 AVC had Transthoracic echocardiogram (TTE). The interval time between CT scan and TTE was variable.   Aortic valve calcification in CT chest scans is a common finding and studies have shown that it is strongly related to the presence and severity of aortic valve disease. As CT scans are considered as a valuable additional screening tool for detection of aortic stenosis, AVC should always be commented upon in the radiology reports. Furthermore, patients with at least Grade III and IV AVC should be sent for TTE. © 2012 Blackwell Publishing Ltd.

  9. CT and MRI Findings in Cerebral Aspergilloma.

    PubMed

    Gärtner, Friederike; Forstenpointner, Julia; Ertl-Wagner, Birgit; Hooshmand, Babak; Riedel, Christian; Jansen, Olav

    2017-11-20

    Purpose  Invasive aspergillosis usually affects immunocompromised patients. It carries a high risk of morbidity and mortality and usually has a nonspecific clinical presentation. Early diagnosis is essential in order to start effective treatment and improve clinical outcome. Materials and Methods  In a retrospective search of the PACS databases from two medical centers, we identified 9 patients with histologically proven cerebral aspergilloma. We systematically analyzed CT and MRI imaging findings to identify typical imaging appearances of cerebral aspergilloma. Results  CT did not show a typical appearance of the aspergillomas. In 100 % (9/9) there was a rim-attenuated diffusion restriction on MRI imaging. Multiple hypointense layers in the aspergillus wall, especially on the internal side, were detected in 100 % on T2-weighted imaging (9/9). Aspergillomas were T1-hypointense in 66 % of cases (6/9) and partly T1-hyperintense in 33 % (3/9). In 78 % (7/9) of cases, a rim-attenuated diffusion restriction was detected after contrast agent application. Conclusion  Nine cases were identified. Whereas CT features were less typical, we observed the following imaging features on MRI: A strong, rim-attenuated diffusion restriction (9/9); onion layer-like hypointense zones, in particular in the innermost part of the abscess wall on T2-weighted images (9/9). Enhancement of the lesion border was present in the majority of the cases (7/9). Key points   · There are typical MRI imaging features of aspergillomas.. · However, these findings could be affected by the immune status of the patient.. · Swift identification of aspergilloma imaging patterns is essential to allow for adequate therapeutic decision making.. Citation Format · Gärtner F, Forstenpointner J, Ertl-Wagner B et al. CT and MRI Findings in Cerebral Aspergilloma. Fortschr Röntgenstr 2017; DOI: 10.1055/s-0043-120766. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Athlete shoulder injuries: CT arthrographic findings.

    PubMed

    Rafii, M; Firooznia, H; Bonamo, J J; Minkoff, J; Golimbu, C

    1987-02-01

    Forty-three professional and amateur athletes with persistent shoulder pain that interfered with their sports activities were evaluated by computed tomographic (CT) arthrography. In 19 patients, glenohumeral instability (14 anterior, two posterior, three multidirectional) was diagnosed with CT arthrography based on the simultaneous presence of labral and capsular lesions. The findings were crucial in establishing the diagnosis of instability in six patients in whom the condition was not suggested or could not be confirmed clinically. Another significant injury consisted of labral lesions not associated with glenohumeral instability. These tears often involved the anterior and parasuperior segments of this structure. Other, less frequently detected lesions included segmental labral enlargement and several labra with abnormal orientation (everted labrum). Early onset of degenerative disease was present in many athletes, especially those with a long history of sports activity. CT arthrographic findings were correlated with arthroscopic or surgical results in 19 patients.

  11. Chest CT findings of toxocariasis: correlation with laboratory results.

    PubMed

    Hur, J H; Lee, I J; Kim, J-H; Kim, D-G; Hwang, H J; Koh, S H; Lee, K

    2014-06-01

    To assess the relationship between chest computed tomography (CT) findings of patients with toxocariasis and levels of serological markers. A total of 38 cases of patients diagnosed with toxocariasis by enzyme-linked immunosorbent assay (ELISA), CT, and serological markers were retrospectively reviewed. The presence of nodule with or without ground-glass opacity (GGO) halo, consolidation, focal GGO, pleural effusion, and lymphadenopathy at chest CT were evaluated. Statistical analysis was performed with the Fisher's exact test. The most common chest CT findings were nodule (n = 12, 31.6%) and focal GGO (n = 12, 31.6%). In patients with normal eosinophil levels, focal GGO (n = 9, 37.5%) was the most common finding. In contrast, nodule with a GGO halo (n = 7, 50%) was the most common finding in the eosinophilia group. Nodule with a GGO halo was more common in the eosinophilia group, with a statistically significant difference (p = 0.017). Nodule was more common in the eosinophilia group, and focal GGO was more common in the normal eosinophil group. The most common chest CT findings in toxocariasis were nodule with or without GGO halo, and focal GGO. In the eosinophilia group, nodule with a GGO halo was significantly more frequent. Other CT findings did not show a statistically significant relationship with serological markers. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. Scrub typhus associated hepatic dysfunction and abdominal CT findings

    PubMed Central

    Park, Man Je; Lee, Hyoun Soo; Shim, Sang Goon; Kim, So Hee

    2015-01-01

    Objective: This retrospective study investigated abnormal hepatic dysfunction and abdominal computed tomography (CT) findings in scrub typhus. Methods: Three hundred forty nine adult patients were diagnosed with scrub typhus. Ninety four underwent abdominal CT. The CT images were reviewed by the attending radiologist. Patient data of history, symptoms, signs, and results of laboratory tests were collected from the electronic medical records. Results: In 349 patients with scrub typhus, elevation of aspartate aminotransferase (78.5%) and alanine aminotransferase (63.0%) were dominant compared to alkaline phosphatase (27.2%) and total bilirubin (16.1%). Abdominal CT findings of 94 patients were, in descending order of frequency, enlarged lymph node (53.2%), inhomogeneous enhancement of liver (47.9%), splenomegaly (46.8%), ascites (28.7%), low attenuation of periportal areas (27.7%), gallbladder wall thickening (17.0%), and splenic infarct (6.4%). Also, the level of aspartate aminotransferase tended to be elevated according to the number of CT findings (P= 0.028) Conclusions: We found that abdominal CT manifestations of scrub typhus with elevated aminotransferases were varied and not specific. However, knowledge of these findings may evoke the recognition of scrub typhus by clinicians in endemic areas. PMID:26101478

  13. A case of severe sepsis presenting marked decrease of neutrophils and interesting findings on dynamic CT.

    PubMed

    Makino, Isamu; Tajima, Hidehiro; Kitagawa, Hirohisa; Nakagawara, Hisatoshi; Miyashita, Tomoharu; Nakanuma, Shinichi; Hayashi, Hironori; Takamura, Hiroyuki; Fushida, Sachio; Ohta, Tetsuo

    2015-05-28

    In a patient with severe sepsis, we sometimes observe immediate decrease of the counts of white blood cells (WBCs) and neutrophils, which is known as an indicator for poor prognosis. We observed marked decrease of white blood cells and neutrophils on blood examination and interesting findings on dynamic CT. Here, we present the case of a patient with severe postoperative sepsis occurring after major abdominal surgery and we discuss the mechanism of such clinical presentations. A 60-year-old man received pancreatoduodenectomy with colectomy for pancreatic cancer. He developed a high fever on postoperative day 3. We observed marked decrease of WBCs and neutrophils on blood examination. We also observed slight swelling of the liver, inhomogeneous enhancement of liver parenchyma in arterial phase, and periportal low density in the Glisson capsule in portal phase, without any findings indicating infectious complications on dynamic CT. WBCs and neutrophils increased above normal range in just 6 hours. Blood culture examination performed while the patient had a high fever was positive for Aeromonas hydrophila. After receiving intensive care, he promptly recovered from severe sepsis. The CT findings disappeared on second dynamic CT examination performed 3 days after the first examination. We treated a patient with severe sepsis after major abdominal surgery who presented very rapid change of the counts of WBCs and neutrophils and interesting CT findings in the liver. We rescued him from a critical situation by prompt and intensive treatment. Research is needed to accumulate and analyze data from more patients who present a similar clinical course to better understand their pathophysiological conditions.

  14. Bowel obstruction complicated by ischemia: analysis of CT findings.

    PubMed

    Cox, Veronica L; Tahvildari, Ali M; Johnson, Benjamin; Wei, Wei; Jeffrey, R Brooke

    2018-06-01

    To analyze CT signs of bowel ischemia in patients with surgical bowel obstruction, and thereby improve CT diagnosis in this common clinical scenario. Surgical and histopathological findings were used as the reference standard. We retrospectively analyzed CT findings in patients brought to surgery for bowel obstruction over 13 years. Etiology of obstruction (adhesion, hernia, etc.) was recorded. Specific CT features of acute mesenteric ischemia (AMI) were analyzed, including bowel wall thickening, mucosal hypoenhancement, and others. 173 cases were eligible for analysis. 21% of cases were positive for bowel ischemia. Volvulus, internal hernia, and closed-loop obstructions showed ischemia rates of 60%, 43%, and 43%; ischemia rate in obstruction from simple adhesion was 21%. Patients with bowel obstruction related to malignancy were never ischemic. Sensitivities and specificities for CT features predicting ischemia were calculated, with wall thickening, hypoenhancement, and pneumatosis showing high specificity for ischemia (86%-100%). Wall thickening, hypoenhancement, and pneumatosis are highly specific CT signs of ischemia in the setting of obstruction. None of the evaluated CT signs were found to be highly sensitive. Overall frequency of ischemia in surgical bowel obstruction is 21%, and 2-3 times that for complex obstructions (volvulus, closed loop, etc.). Obstructions related to malignancy virtually never become ischemic.

  15. Colloid Adenocarcinoma of the Lung: CT and PET/CT Findings in Seven Patients.

    PubMed

    Kim, Han Kyul; Han, Joungho; Franks, Teri J; Lee, Kyung Soo; Kim, Tae Jung; Choi, Joon Young; Zo, Jaeil

    2018-05-24

    We aimed to assess CT and 18 F-FDG PET/CT findings of colloid adenocarcinoma of the lung in seven patients. From 2010 to 2017, seven patients with surgically proven colloid adenocarcinoma of the lung were identified. CT (both enhanced and unenhanced) and PET/CT findings were analyzed, and the imaging features were compared with histopathologic reports. Clinical and demographic features were also analyzed. In all cases except one, tumors showed low attenuation on unenhanced CT scans, ranging in attenuation from -16.5 to 20.7 HU (median, 9.2 HU). After contrast medium injection, enhancement was scant, so net enhancement ranged from 0.4 to 29.0 HU (median, 4.1 HU). All tumors had a lobulated contour. Stippled calcifications within the tumor were seen in one patient. The maximum standardized uptake value of tumors on PET/CT ranged from 1.5 to 4.5 (median, 3.5). In six of seven patients, FDG accumulation was seen in the tumor walls (n = 3, curvilinear uptake) or in both the tumor walls and tumor septa (n = 3, crisscross uptake). Six patients were alive without recurrence after a median follow-up period of 2.3 years (range, 2 months to 5 years). In one patient, who was alive at follow-up 4 years after imaging and had received adjuvant concurrent chemoradiation therapy after lobectomy, recurrent disease was detected 6 months after completion of the therapy. On CT, pulmonary colloid adenocarcinomas present as lobulated homogeneously low-attenuation tumors. At PET, curvilinear or crisscross FDG uptake is seen within the tumor where tumor cells are lining the walls or septal structures.

  16. Nosocomial rapidly growing mycobacterial infections following laparoscopic surgery: CT imaging findings.

    PubMed

    Volpato, Richard; de Castro, Claudio Campi; Hadad, David Jamil; da Silva Souza Ribeiro, Flavya; Filho, Ezequiel Leal; Marcal, Leonardo P

    2015-09-01

    To identify the distribution and frequency of computed tomography (CT) findings in patients with nosocomial rapidly growing mycobacterial (RGM) infection after laparoscopic surgery. A descriptive retrospective study in patients with RGM infection after laparoscopic surgery who underwent CT imaging prior to initiation of therapy. The images were analyzed by two radiologists in consensus, who evaluated the skin/subcutaneous tissues, the abdominal wall, and intraperitoneal region separately. The patterns of involvement were tabulated as: densification, collections, nodules (≥1.0 cm), small nodules (<1.0 cm), pseudocavitated nodules, and small pseudocavitated nodules. Twenty-six patients met the established criteria. The subcutaneous findings were: densification (88.5%), small nodules (61.5%), small pseudocavitated nodules (23.1 %), nodules (38.5%), pseudocavitated nodules (15.4%), and collections (26.9%). The findings in the abdominal wall were: densification (61.5%), pseudocavitated nodules (3.8%), and collections (15.4%). The intraperitoneal findings were: densification (46.1%), small nodules (42.3%), nodules (15.4%), and collections (11.5%). Subcutaneous CT findings in descending order of frequency were: densification, small nodules, nodules, small pseudocavitated nodules, pseudocavitated nodules, and collections. The musculo-fascial plane CT findings were: densification, collections, and pseudocavitated nodules. The intraperitoneal CT findings were: densification, small nodules, nodules, and collections. • Rapidly growing mycobacterial infection may occur following laparoscopy. • Post-laparoscopy mycobacterial infection CT findings are densification, collection, and nodules. • Rapidly growing mycobacterial infection following laparoscopy may involve the peritoneal cavity. • Post-laparoscopy rapidly growing mycobacterial intraperitoneal infection is not associated with ascites or lymphadenopathy.

  17. FDG PET/CT findings in acquired perforating dermatosis.

    PubMed

    Shinmura, Akiko; Abe, Koichiro; Baba, Shingo; Isoda, Takuro; Maruoka, Yasuhiro; Yasukawa, Fumiko; Kiryu, Hiromaro; Sasaki, Masayuki; Furue, Masutaka; Honda, Hiroshi

    2012-10-01

    Acquired perforating dermatosis (APD) is an uncommon cutaneous perforating disorder. We report a patient on hemodialysis who developed skin eruption and jaundice. He underwent FDG PET/CT under suspicion of biliary malignancies. PET/CT showed no significant abnormal uptake except of multiple FDG-avid nodules in the skin. The eruption he had was histopathologically diagnosed as APD by skin biopsy. His case suggests that APD should be considered as a differential diagnosis when multiple cutaneous FDG accumulations are found in a patient on hemodialysis. To the best of our knowledge, this is the first report showing the FDG PET/CT findings of APD.

  18. Pulmonary Toxocariasis: Initial and Follow-Up CT Findings in 63 Patients.

    PubMed

    Lee, Kyung Hee; Kim, Tae Jung; Lee, Kyung Won

    2015-06-01

    The objective of our study was to describe the characteristic radiologic findings of pulmonary toxocariasis on initial and follow-up chest CT. Between June 2010 and May 2014, 63 patients with serologically proven, clinically diagnosed pulmonary toxocariasis and chest CT examinations performed within 2 months of an enzyme-linked immunosorbent assay for toxocariasis were identified. Two chest radiologists retrospectively analyzed the chest CT examinations in consensus; they focused on the distribution, location, number, and internal characteristics of the pulmonary lesions. The pulmonary lesions tended to involve three or more lobes (49% [31/63]) on the initial CT; predominance of the abnormalities in a subpleural location (81% [51/63]) and in the lower lung zone (98% [62/63]) was noted. The number of pulmonary lesions per patient were from two to five (46% [29/63]), more than five (32% [20/63]), or one (22% [14/63]). The radiologic findings of pulmonary toxocariasis could be categorized into four different patterns: ground-glass opacities (GGOs), solid nodules, consolidations, and linear opacities. The most common pattern was ill-defined GGOs with or without solid portions (84% [53/63]). The solid nodule and patchy consolidation patterns were found in 29% (18/63) and 21% (13/63) of patients, respectively. In addition, linear opacities (1-2 mm thick and 8-25 mm long) were present in 19% of patients (12/63); this finding is a subtle, yet novel, finding. On follow-up CT, the pulmonary lesions had either disappeared or migrated; when they had migrated, they revealed radiologic manifestations similar to the findings on the initial CT. Pulmonary toxocariasis manifested as multiple lesions in four radiologic patterns with subpleural and lower lung predominance on initial and follow-up CT. A linear opacity may be one of many clues in the diagnosis of pulmonary toxocariasis on CT.

  19. CT findings in hydrocarbon pneumonitis after diesel fuel siphonage.

    PubMed

    Yi, Mi Seon; Kim, Kun-Il; Jeong, Yeon Joo; Park, Hye Kyung; Lee, Min Ki

    2009-10-01

    The purpose of this study was to assess CT findings in a series of patients with hydrocarbon pneumonitis after diesel fuel siphonage. The characteristic CT findings of hydrocarbon pneumonitis after diesel fuel siphonage are the presence of air-space consolidations with predominant right middle lobe involvement and areas of low attenuation within consolidation. Occasionally, bronchoalveolar lavage is needed to confirm the diagnosis of hydrocarbon pneumonitis by the presence of lipid-laden macrophages on the basis of a history of diesel fuel aspiration.

  20. CT findings of pulmonary tuberculosis and tuberculous pleurisy in diabetes mellitus patients.

    PubMed

    Kim, Jihyun; Lee, In Jae; Kim, Joo Hee

    2017-01-01

    We aimed to assess computed tomography (CT) findings of pulmonary tuberculosis (TB) and TB pleurisy in diabetes mellitus (DM) patients and to evaluate the effect of duration of DM on radiologic findings of pulmonary TB and TB pleurisy. Ninety-three consecutive patients diagnosed as active pulmonary TB with underlying DM were enrolled in our study. As a control group, 100 pulmonary TB patients without DM were randomly selected. TB patients with DM were subdivided into two subgroups depending on diabetes duration of ≥10 years or <10 years. Medical records and CT scans of the patients were retrospectively reviewed and compared. Bilateral pulmonary involvement (odds ratio [OR]=2.39, P = 0.003), involvement of all lobes (OR=2.79, P = 0.013), and lymph node enlargement (OR=1.98, P = 0.022) were significantly more frequent CT findings among TB patients with DM compared with the controls. There were no statistically significant differences in CT findings of pulmonary TB depending on the duration of DM. Bilateral pulmonary involvement, involvement of all lobes, and lymph node enlargement are significantly more common CT findings in TB patients with underlying DM than in patients without DM. Familiarity with the CT findings may be helpful to suggest prompt diagnosis of pulmonary TB in DM patients.

  1. Managing incidental findings on abdominal CT: white paper of the ACR incidental findings committee.

    PubMed

    Berland, Lincoln L; Silverman, Stuart G; Gore, Richard M; Mayo-Smith, William W; Megibow, Alec J; Yee, Judy; Brink, James A; Baker, Mark E; Federle, Michael P; Foley, W Dennis; Francis, Isaac R; Herts, Brian R; Israel, Gary M; Krinsky, Glenn; Platt, Joel F; Shuman, William P; Taylor, Andrew J

    2010-10-01

    As multidetector CT has come to play a more central role in medical care and as CT image quality has improved, there has been an increase in the frequency of detecting "incidental findings," defined as findings that are unrelated to the clinical indication for the imaging examination performed. These "incidentalomas," as they are also called, often confound physicians and patients with how to manage them. Although it is known that most incidental findings are likely benign and often have little or no clinical significance, the inclination to evaluate them is often driven by physician and patient unwillingness to accept uncertainty, even given the rare possibility of an important diagnosis. The evaluation and surveillance of incidental findings have also been cited as among the causes for the increased utilization of cross-sectional imaging. Indeed, incidental findings may be serious, and hence, when and how to evaluate them are unclear. The workup of incidentalomas has varied widely by physician and region, and some standardization is desirable in light of the current need to limit costs and reduce risk to patients. Subjecting a patient with an incidentaloma to unnecessary testing and treatment can result in a potentially injurious and expensive cascade of tests and procedures. With the participation of other radiologic organizations listed herein, the ACR formed the Incidental Findings Committee to derive a practical and medically appropriate approach to managing incidental findings on CT scans of the abdomen and pelvis. The committee has used a consensus method based on repeated reviews and revisions of this document and a collective review and interpretation of relevant literature. This white paper provides guidance developed by this committee for addressing incidental findings in the kidneys, liver, adrenal glands, and pancreas. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Demonstration of infective endocarditis by cardiac CT and transoesophageal echocardiography: comparison with intra-operative findings.

    PubMed

    Koo, Hyun Jung; Yang, Dong Hyun; Kang, Joon-Won; Lee, Joo Yeon; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae-Won; Lim, Tae-Hwan

    2018-02-01

    We aimed to compare imaging findings of infective endocarditis between computed tomography (CT) and transoesophageal echocardiography (TEE) using surgical inspection as a reference standard. Forty-nine patients (aged 54 ± 17 years, 69% men) who underwent pre-operative CT and TEE for infective endocarditis were included. Twelve of these patients had prosthetic valve endocarditis. Imaging findings of infective endocarditis were classified as vegetation, leaflet perforation, abscess/pseudoaneurysm, and paravalvular leakage. Diagnostic performances of CT and TEE were evaluated using surgical inspection as a reference standard. Interobserver agreements for CT findings were obtained using Cohen's κ test. The detection rates of infective endocarditis per patient with CT and TEE were 93.9% (46/49) and 95.9% (47/49), respectively. In per-imaging analysis, the sensitivities of CT and TEE were not significantly different for both native and prosthetic valve infective endocarditis (sensitivity: vegetation, 100% in TEE and 90.9% in CT; leaflet perforation, 87.5% in TEE and 50.0% in CT; abscess/pseudoaneurysm, 40.0% in TEE and 60.0% in CT; paravalvular leakage, 100% in TEE and 50.0% in CT). Interobserver agreements for CT findings were substantial or excellent (0.79-0.88). Cardiac CT can accurately demonstrate infective endocarditis in pre-operative patients with a similar diagnostic accuracy to TEE. The interobserver agreements for the CT findings of infective endocarditis were excellent. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  3. Incidental findings in children with blunt head trauma evaluated with cranial CT scans.

    PubMed

    Rogers, Alexander J; Maher, Cormac O; Schunk, Jeff E; Quayle, Kimberly; Jacobs, Elizabeth; Lichenstein, Richard; Powell, Elizabeth; Miskin, Michelle; Dayan, Peter; Holmes, James F; Kuppermann, Nathan

    2013-08-01

    Cranial computed tomography (CT) scans are frequently obtained in the evaluation of blunt head trauma in children. These scans may detect unexpected incidental findings. The objectives of this study were to determine the prevalence and significance of incidental findings on cranial CT scans in children evaluated for blunt head trauma. This was a secondary analysis of a multicenter study of pediatric blunt head trauma. Patients <18 years of age with blunt head trauma were eligible, with those undergoing cranial CT scan included in this substudy. Patients with coagulopathies, ventricular shunts, known previous brain surgery or abnormalities were excluded. We abstracted radiology reports for nontraumatic findings. We reviewed and categorized findings by their clinical urgency. Of the 43,904 head-injured children enrolled in the parent study, 15,831 underwent CT scans, and these latter patients serve as the study cohort. On 670 of these scans, nontraumatic findings were identified, with 16 excluded due to previously known abnormalities or surgeries. The remaining 654 represent a 4% prevalence of incidental findings. Of these, 195 (30%), representing 1% of the overall sample, warranted immediate intervention or outpatient follow-up. A small but important number of children evaluated with CT scans after blunt head trauma had incidental findings. Physicians who order cranial CTs must be prepared to interpret incidental findings, communicate with families, and ensure appropriate follow-up. There are ethical implications and potential health impacts of informing patients about incidental findings.

  4. Correlation between human observer performance and model observer performance in differential phase contrast CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ke; Garrett, John; Chen, Guang-Hong

    2013-11-15

    Purpose: With the recently expanding interest and developments in x-ray differential phase contrast CT (DPC-CT), the evaluation of its task-specific detection performance and comparison with the corresponding absorption CT under a given radiation dose constraint become increasingly important. Mathematical model observers are often used to quantify the performance of imaging systems, but their correlations with actual human observers need to be confirmed for each new imaging method. This work is an investigation of the effects of stochastic DPC-CT noise on the correlation of detection performance between model and human observers with signal-known-exactly (SKE) detection tasks.Methods: The detectabilities of different objectsmore » (five disks with different diameters and two breast lesion masses) embedded in an experimental DPC-CT noise background were assessed using both model and human observers. The detectability of the disk and lesion signals was then measured using five types of model observers including the prewhitening ideal observer, the nonprewhitening (NPW) observer, the nonprewhitening observer with eye filter and internal noise (NPWEi), the prewhitening observer with eye filter and internal noise (PWEi), and the channelized Hotelling observer (CHO). The same objects were also evaluated by four human observers using the two-alternative forced choice method. The results from the model observer experiment were quantitatively compared to the human observer results to assess the correlation between the two techniques.Results: The contrast-to-detail (CD) curve generated by the human observers for the disk-detection experiments shows that the required contrast to detect a disk is inversely proportional to the square root of the disk size. Based on the CD curves, the ideal and NPW observers tend to systematically overestimate the performance of the human observers. The NPWEi and PWEi observers did not predict human performance well either, as the slopes of

  5. Crackle analysis for chest auscultation and comparison with high-resolution CT findings.

    PubMed

    Kawamura, Takeo; Matsumoto, Tsuneo; Tanaka, Nobuyuki; Kido, Shoji; Jiang, Zhongwei; Matsunaga, Naofumi

    2003-01-01

    The purpose of our study was to clarify the correlation between respiratory sounds and the high-resolution CT (HRCT) findings of lung diseases. Respiratory sounds were recorded using a stethoscope in 41 patients with crackles. All had undergone inspiratory and expiratory CT. Subjects included 18 patients with interstitial pneumonia and 23 without interstitial pneumonia. Two parameters, two-cycle duration (2CD) and initial deflection width (IDW) of the "crackle," were induced by time-expanded waveform analysis. Two radiologists independently assessed 11 HRCT findings. An evaluation was carried out to determine whether there was a significant difference in the two parameters between the presence and absence of each HRCT finding. The two parameters of crackles were significantly shorter in the interstitial pneumonia group than the non-interstitial pneumonia group. Ground-glass opacity, honeycombing, lung volume reduction, traction bronchiectasis, centrilobular nodules, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were correlated with one or two parameters in all patients, whereas the other three findings were not. Among the interstitial pneumonia group, traction bronchiectasis, emphysematous change, and attenuation and volume change between inspiratory and expiratory CT were significantly correlated with one or two parameters. Abnormal respiratory sounds were correlated with some HRCT findings.

  6. Postmortem computed tomography in victims of military air mishaps: radiological-pathological correlation of CT findings.

    PubMed

    Levy, Gad; Goldstein, Liav; Blachar, Arye; Apter, Sara; Barenboim, Erez; Bar-Dayan, Yaron; Shamis, Ari; Atar, Eli

    2007-10-01

    A thorough medical inquiry is included in every aviation mishap investigation. While the gold standard of this investigation is a forensic pathology examination, numerous reports stress the important role of computed tomography in the postmortem evaluation of trauma victims. To characterize the findings identified by postmortem CT and compare its performance to conventional autopsy in victims of military aviation mishaps, we analyzed seven postmortem CT examinations. Musculoskeletal injuries accounted for 57.8% of the traumatic findings identified by postmortem CT. The most frequent findings were fractures of the rib (47%), skull (9.6%) and facial bones (8.6%). Abnormally located air accounted for 24% of findings, for which CT was superior (3.5% detected by autopsy, 100% by postmortem CT, P < 0.001). The performance of autopsy in detecting injuries was superior (autopsy detected 85.8% of all injuries, postmortem CT detected 53.9%, P < 0.001), especially in the detection of superficial lesions (100% detected by autopsy, 10.5% by postmortem CT, P < 0.001) and solid organ injuries (100% by autopsy, 18.5% by postmortem CT, P < 0.001). Performance in the detection of musculoskeletal injuries was similar (91.3% for autopsy, 90.3% for postmortem CT, P = not significant). Postmortem CT and autopsy have distinct performance profiles, and although the first cannot replace the latter it is a useful complementary examination.

  7. Lumbar spine: pretest predictability of CT findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giles, D.J.; Thomas, R.J.; Osborn, A.G.

    Demographic and symptomatic data gathered from 460 patients referred for lumbosacral CT examinations were analyzed to determine if the prescan probability of normal or abnormal findings could be predicted accurately. The authors were unable to predict the presence of herniated disk on the basis of patient-supplied data alone. Age was the single most significant predictor of an abnormality and was sharply related to degenerative disease and spinal stenosis.

  8. FDG PET/CT findings in a case of myositis ossificans circumscripta of the forearm.

    PubMed

    Clarençon, Frédéric; Larousserie, Frédérique; Babinet, Antoine; Zylbersztein, Christophe; Talbot, Jean-Noël; Kerrou, Khaldoun

    2011-01-01

    Myositis ossificans circumscripta (MOC) is a rare benign neoplasm located in soft tissues that, most of the time, appears after a local trauma. The positive diagnosis of MOC may be challenging on CT or MRI findings. We report on an atypical case of a spontaneous nontraumatic MOC in a 54-year-old man, located in the longus supinatus muscle diagnosed with MRI and F-18 FDG PET/CT findings. Rarely described F-18 FDG PET/CT features in MOC are presented. Pattern of avid FDG focus on PET/CT, that may wrongly suggest osteosarcoma, is presented.

  9. [Comparison of CT findings between gastric cancer and gastric lymphoma].

    PubMed

    Fan, Wei-Jun; Lu, Yan-Chun; Liu, Li-Zhi; Shen, Jing-Xian; Xie, Chuan-Miao; Li, Xian; Zhang, Liang

    2008-05-01

    It is difficult to discriminate progressive gastric cancer and gastric lymphoma by CT imaging, because incrassate gastric wall, lump in gastric cavity, confined gastric cavity, intumescent lymph node, and distant metastasis can be displayed in both of them. This study was to compare the CT findings between gastric cancer and gastric lymphoma to improve diagnosis of gastric tumors, especially for gastric lymphoma. CT images of 27 patients with pathologically proved progressive gastric cancer and 25 patients with pathologically proved gastric lymphoma were reviewed. Tumor location, appearance, scope of involvement, gastric wall thickness, mucous membrane, mucosal fold, serosa membrane, necrosis, enhancement degree and uniformity, involvement of other organs, and abdominal lymph nodes were observed. White line sign was observed in 23 cases (85.2%) of gastric cancer, but not in the 25 cases of gastric lymphoma. The extent of white line sign in gastric cancers was larger in portal vein phase than in arterial phase. Enhancement degree outside the white line was higher in portal vein phase than in arterial phase in 13 cases (48.1%) of gastric cancer. The extent of involved gastric wall was smaller than 50% of the whole gastric wall in all the 27 cases of gastric cancer, while it was larger than 75% in 23 cases (85.2%) of gastric lymphoma. Gastric mucous membrane ulcer was found in all of the 27 cases (100%) of gastric cancer, while it was found in only 1 case (4.0%) of gastric lymphoma. Intumescent lymph nodes in two or more areas were found in 11 cases (40.0%) of gastric lymphoma, but not in gastric cancer. Intumescent lymph nodes in the retroperitoneal space below renal hilum were found in 8 cases (32%) of gastric lymphoma, but not in gastric cancer. There are some different CT features between gastric cancer and gastric lymphoma, such as white line sign, gastric mucous membrane ulcer, extent of involved gastric wall, location of intumescent lymph nodes surrounding the

  10. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    NASA Astrophysics Data System (ADS)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  11. CT Imaging Findings after Craniosynostosis Reconstructive Surgery.

    PubMed

    Ginat, Daniel Thomas; Lam, Daniel; Kuhn, Andrew Scott; Reid, Russell

    2018-06-06

    Several surgical options are available for treating the different types of craniosynostosis, including fronto-orbital advancement and remodeling, total or subtotal cranial vault remodeling, barrel stave osteotomy with cranial remodeling, endoscopic suturectomy, monobloc advancement and cranioplasty, and revision cranioplasty. High-resolution, low-dose CT with 3D reconstructed images and volumetric analysis can be useful for evaluating the craniofacial skeleton following surgery. The various types of craniosynostosis surgery and corresponding imaging findings are reviewed in this article. © 2018 S. Karger AG, Basel.

  12. 3D documentation and visualization of external injury findings by integration of simple photography in CT/MRI data sets (IprojeCT).

    PubMed

    Campana, Lorenzo; Breitbeck, Robert; Bauer-Kreuz, Regula; Buck, Ursula

    2016-05-01

    This study evaluated the feasibility of documenting patterned injury using three dimensions and true colour photography without complex 3D surface documentation methods. This method is based on a generated 3D surface model using radiologic slice images (CT) while the colour information is derived from photographs taken with commercially available cameras. The external patterned injuries were documented in 16 cases using digital photography as well as highly precise photogrammetry-supported 3D structured light scanning. The internal findings of these deceased were recorded using CT and MRI. For registration of the internal with the external data, two different types of radiographic markers were used and compared. The 3D surface model generated from CT slice images was linked with the photographs, and thereby digital true-colour 3D models of the patterned injuries could be created (Image projection onto CT/IprojeCT). In addition, these external models were merged with the models of the somatic interior. We demonstrated that 3D documentation and visualization of external injury findings by integration of digital photography in CT/MRI data sets is suitable for the 3D documentation of individual patterned injuries to a body. Nevertheless, this documentation method is not a substitution for photogrammetry and surface scanning, especially when the entire bodily surface is to be recorded in three dimensions including all external findings, and when precise data is required for comparing highly detailed injury features with the injury-inflicting tool.

  13. The scab-like sign: A CT finding indicative of haemoptysis in patients with chronic pulmonary aspergillosis?

    PubMed

    Sato, Haruka; Okada, Fumito; Matsumoto, Shunro; Mori, Hiromu; Kashiwagi, Junji; Komatsu, Eiji; Maeda, Toru; Nishida, Haruto; Daa, Tsutomu; Ohtani, Satoshi; Umeki, Kenji; Ando, Masaru; Kadota, Junichi

    2018-05-03

    The aim of this study was to assess the CT findings that characterise haemoptysis in patients with chronic pulmonary aspergillosis (CPA). We retrospectively identified 120 consecutive patients with CPA (84 men and 36 women, 17-89 years of age, mean age 68.4 years) who had undergone a total of 829 CT examinations between January 2007 and February 2017. In the 11 patients who underwent surgical resection, CT images were compared with the pathological results. The scab-like sign was seen on 142 of the 829 CT scans, specifically, in 87 of the 90 CT scans for haemoptysis and in 55 of the 739 CT scans obtained during therapy evaluation. In 48 of those 55 patients, haemoptysis occurred within 55 days (mean 12.0 days) after the CT scan. In the 687 CT scans with no scab-like sign, there were only three instances of subsequent haemoptysis in the respective patients over the following 6 months. Patients with and without scab-like sign differed significantly in the frequency of haemoptysis occurring after a CT scan (p<0.0001). Pathologically, the scab-like sign corresponded to a fibrinopurulent mass or blood crust. The scab-like sign should be considered as a CT finding indicative of haemoptysis. • Haemoptysis is commonly found in patients with CPA. • A CT finding indicative of haemoptysis in CPA patients is described. • Scab-like sign may identify CPA patients at higher risk of haemoptysis.

  14. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease.

    PubMed

    Malik, Archana; Hellinger, Jeffrey C; Servaes, Sabah; Schwartz, Mathew C; Keller, Marc S; Epelman, Monica

    2017-03-01

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the

  15. Peritoneal manifestations of fascioliasis on CT images: a new observation.

    PubMed

    Song, Kyoung Doo; Lim, Jae Hoon; Kim, Mi Jeong; Jang, Yun Jin; Kim, Jae Woon; Cho, Seung Hyun; Kwon, Jung Hyeok

    2013-08-01

    To describe peritoneal manifestations of fascioliasis on CT. We reviewed CT images in 31 patients with fascioliasis confirmed by enzyme-linked immunosorbent assay (ELISA) (n = 24) or surgery (n = 7). Image analyses were performed to identify hepatic, biliary, and peritoneal abnormalities. Hepatic abnormalities were seen in 28 (90.3 %) of the 31 patients. The most common finding was caves sign, which was present in 25 (80.1 %) patients. Three patients (9.7 %) presented with biliary abnormalities exhibiting dilatation and enhancing wall thickening of the bile duct, wall thickening of the gallbladder, and elongated structures in the bile duct or gallbladder. Peritoneal abnormalities were seen in 14 (45.2 %) of the 31 patients. The most common peritoneal abnormality was mesenteric or omental infiltration, which was seen in 9 (29.0 %) patients. Other peritoneal findings included lymph node enlargement (n = 7), ascites (n = 7), thickening of ligamentum teres (n = 2), and peritoneal mass (n = 2). Peritoneal manifestations of fascioliasis are relatively common, and CT findings include mesenteric or omental infiltration, lymph node enlargement, ascites, thickening of the ligamentum teres, and peritoneal masses.

  16. Ventricular myocardial fat: CT findings and clinical correlates.

    PubMed

    Jacobi, Adam H; Gohari, Arash; Zalta, Benjamin; Stein, Marjorie W; Haramati, Linda B

    2007-05-01

    Replacement of the myocardium by fat is a feature of arrythmogenic right ventricular dysplasia (ARVD). Pathology literature describes ventricular myocardial fat to be present not only in ARVD, but much more frequently related to aging, prior myocardial infarction (MI), and chronic ischemia. We noted focal ventricular myocardial fat in a group of patients who underwent chest computed tomography (CT) for varied indications. The aim of this study is to describe the noncontrast CT findings and clinical correlates of ventricular myocardial fat in this population. We prospectively identified 26 patients whose noncontrast chest CT (5/03 to 6/04) demonstrated ventricular myocardial fat and whose clinical charts were available. There were 14 men and 12 women with a mean age of 70 years. Twenty-three percent (6/26) had prior CTs. Each CT was reviewed by 3 radiologists in consensus. The site of the ventricular fat was noted. Each patient was categorized based on the location of the fat as follows: group 1-right ventricle (RV) only, group 2-left ventricle (LV) only, group 3-biventricular. Results of cardiac history, laboratory tests, and cardiac imaging were noted. The distribution of ventricular myocardial fat was: group 1 RV-27% (7/26), group 2 LV-46% (12/26), and group 3 biventricular-27% (7/26). Echocardiographic, nuclear cardiology, or electrocardiographic data localizing a prior MI to a specific site were available in 35% (9/26) of patients: 14% (1/7) of group 1, 50% (6/12) of group 2, and 29% (2/7) of group 3. Myocardial fat corresponded to the site of MI in 89% (8/9). The presence and distribution of ventricular fat on CT was unchanged from prior CT in 100% (6/6). When comparing group 1 and group 2, group 1 was older (77 vs. 64 y, P=0.005), more often female (57% vs. 17%, P=0.13) and had fewer prior MI (14% vs. 50%, P=0.17) than group 2. Only 1 patient in this series had ARVD. He was in group 3. The significance of ventricular myocardial fat varies by location. Fat in

  17. A combined pulmonary-radiology workshop for visual evaluation of COPD: study design, chest CT findings and concordance with quantitative evaluation.

    PubMed

    Barr, R Graham; Berkowitz, Eugene A; Bigazzi, Francesca; Bode, Frederick; Bon, Jessica; Bowler, Russell P; Chiles, Caroline; Crapo, James D; Criner, Gerard J; Curtis, Jeffrey L; Dass, Chandra; Dirksen, Asger; Dransfield, Mark T; Edula, Goutham; Erikkson, Leif; Friedlander, Adam; Galperin-Aizenberg, Maya; Gefter, Warren B; Gierada, David S; Grenier, Philippe A; Goldin, Jonathan; Han, MeiLan K; Hanania, Nicola A; Hansel, Nadia N; Jacobson, Francine L; Kauczor, Hans-Ulrich; Kinnula, Vuokko L; Lipson, David A; Lynch, David A; MacNee, William; Make, Barry J; Mamary, A James; Mann, Howard; Marchetti, Nathaniel; Mascalchi, Mario; McLennan, Geoffrey; Murphy, James R; Naidich, David; Nath, Hrudaya; Newell, John D; Pistolesi, Massimo; Regan, Elizabeth A; Reilly, John J; Sandhaus, Robert; Schroeder, Joyce D; Sciurba, Frank; Shaker, Saher; Sharafkhaneh, Amir; Silverman, Edwin K; Steiner, Robert M; Strange, Charlton; Sverzellati, Nicola; Tashjian, Joseph H; van Beek, Edwin J R; Washington, Lacey; Washko, George R; Westney, Gloria; Wood, Susan A; Woodruff, Prescott G

    2012-04-01

    The purposes of this study were: to describe chest CT findings in normal non-smoking controls and cigarette smokers with and without COPD; to compare the prevalence of CT abnormalities with severity of COPD; and to evaluate concordance between visual and quantitative chest CT (QCT) scoring. Volumetric inspiratory and expiratory CT scans of 294 subjects, including normal non-smokers, smokers without COPD, and smokers with GOLD Stage I-IV COPD, were scored at a multi-reader workshop using a standardized worksheet. There were 58 observers (33 pulmonologists, 25 radiologists); each scan was scored by 9-11 observers. Interobserver agreement was calculated using kappa statistic. Median score of visual observations was compared with QCT measurements. Interobserver agreement was moderate for the presence or absence of emphysema and for the presence of panlobular emphysema; fair for the presence of centrilobular, paraseptal, and bullous emphysema subtypes and for the presence of bronchial wall thickening; and poor for gas trapping, centrilobular nodularity, mosaic attenuation, and bronchial dilation. Agreement was similar for radiologists and pulmonologists. The prevalence on CT readings of most abnormalities (e.g. emphysema, bronchial wall thickening, mosaic attenuation, expiratory gas trapping) increased significantly with greater COPD severity, while the prevalence of centrilobular nodularity decreased. Concordances between visual scoring and quantitative scoring of emphysema, gas trapping and airway wall thickening were 75%, 87% and 65%, respectively. Despite substantial inter-observer variation, visual assessment of chest CT scans in cigarette smokers provides information regarding lung disease severity; visual scoring may be complementary to quantitative evaluation.

  18. A Rare Case of Malignant Melanoma of the Mandible: 
CT and MRI Findings.

    PubMed

    Ogura, Ichiro; Sasaki, Yoshihiko; Kameta, Ayako; Sue, Mikiko; Oda, Takaaki

    Malignant melanoma of the mandibular gingiva is extremely rare. It is a malignant tumour of melanocytes or their precursor cells, and often misinterpreted as a benign pigmented process. A few reports have described computed tomography (CT) and magnetic resonance imaging (MRI) findings of malignant melanoma in the oral cavity. We report a rare case of malignant melanoma of the mandible and the related CT and MRI findings. Soft tissue algorithm contrast-enhanced CT showed an expansile mass and irregular destruction of alveolar bone in the right side of the mandibular molar area. MR images showed an enhancing mass and the tumour had a low to intermediate signal intensity and a high-signal intensity. Soft tissue algorithm contrast-enhanced CT and MR images showed lymphadenopathy involving the submandibular lymph nodes. Histopathological examination confirmed the diagnosis of malignant melanoma.

  19. CT-Guided Transthoracic Core Biopsy for Pulmonary Tuberculosis: Diagnostic Value of the Histopathological Findings in the Specimen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukuda, Hozumi, E-mail: fkdhzmrad@mitsuihosp.or.jp; Ibukuro, Kenji; Tsukiyama, Toshitaka

    We evaluated the value of CT-guided transthoracic core biopsy for the diagnosis of mycobacterial pulmonary nodules. The 30 subjects in this study had pulmonary nodules that had been either diagnosed histopathologically as tuberculosis or were suspected as tuberculosis based on a specimen obtained by CT-guided transthoracic core biopsy. The histopathological findings, the existence of acid-fast bacilli in the biopsy specimens, and the clinical course of the patients after the biopsy were reviewed retrospectively. Two of the three histological findings for tuberculosis that included epithelioid cells, multinucleated giant cells and caseous necrosis were observed in 21 of the nodules which weremore » therefore diagnosed as histological tuberculosis. Six of these 21 nodules were positive for acid-fast bacilli, confirming the diagnosis of tuberculosis. Thirteen of the 21 nodules did not contain acid-fast bacilli but decreased in size in response to antituberculous treatment and were therefore diagnosed as clinical tuberculosis. Seven nodules with only caseous necrosis were diagnosed as suspected tuberculosis, with a final diagnosis of tuberculosis being made in 4 of the nodules and a diagnosis of old tuberculosis in 2 nodules. Two nodules with only multinucleated giant cells were diagnosed as suspected tuberculosis with 1 of these nodules being diagnosed finally as tuberculosis and the other nodule as a nonspecific granuloma. When any two of the three following histopathological findings - epithelioid cells, multinucleated giant cells or caseous necrosis - are observed in a specimen obtained by CT-guided transthoracic core biopsy, the diagnosis of tuberculosis can be established without the detection of acid-fast bacilli or Mycobacterium tuberculosis.« less

  20. Subprosthetic Pannus after Aortic Valve Replacement Surgery: Cardiac CT Findings and Clinical Features.

    PubMed

    Han, Kichang; Yang, Dong Hyun; Shin, So Youn; Kim, Namkug; Kang, Joon-Won; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won; Lim, Tae-Hwan

    2015-09-01

    To investigate the cardiac computed tomographic (CT) findings and clinical implications of subprosthetic pannus in patients who have undergone aortic valve replacement. The institutional review board approved this retrospective study, and the need to obtain written informed consent was waived. From April 2011 to March 2012, 88 patients (mean age, 63 years; 45 men) with a prosthetic aortic valve who underwent cardiac CT were retrospectively selected. Dynamic cardiac CT images were analyzed by using a multiplanar reformatted technique. The presence or absence of subprosthetic pannus and its extent were evaluated at cardiac CT. The geometric orifice area and the effective orifice area of each prosthetic valve were measured to enable analysis of the pannus encroachment ratio in the systolic phase. Hemodynamic parameters at echocardiography, including mean transprosthetic pressure gradient (MTPG), were compared between patients with and those without pannus. The encroachment ratio and the MTPG were correlated by using the Spearman test to evaluate the relationship between the two variables. Seventeen patients (19%) had subprosthetic pannus at cardiac CT. In patients with subprosthetic pannus, MTPG, peak pressure gradient, transvalvular peak velocity, and left ventricular ejection fraction (LVEF) were significantly higher than in patients without pannus (MTPG: 28.1 mm Hg ± 19.8 [standard deviation] vs 14.0 mm Hg ± 6.5, P = .004; peak pressure gradient: 53.1 mm Hg ± 38.4 vs 26.1 mm Hg ± 11.4, P = .004; transvalvular peak velocity: 3.3 m/sec ± 1.3 vs 2.5 m/sec ± 0.5; and LVEF: 64.7% ± 7.4 vs 56.8% ± 10.5, P = .004). A high MTPG (≥40 mm Hg) was observed in four patients at echocardiography, and subprosthetic panni were identified at CT in all four patients. In patients with increased MTPGs, the encroachment ratio by subprosthetic pannus at CT was significantly higher than that in patients with MTPGs of less than 40 mm Hg (42.7 ± 13.3 vs 7.6 ± 3, P = .012

  1. CNS changes in Usher's syndrome with mental disorder: CT, MRI and PET findings.

    PubMed Central

    Koizumi, J; Ofuku, K; Sakuma, K; Shiraishi, H; Iio, M; Nawano, S

    1988-01-01

    CNS changes in a case of Usher's syndrome associated with schizophrenia-like mental disorder were observed by CT, MRI and PET. The neuro-radiological findings of the case demonstrate the degenerative and metabolic alterations in various regions of cortex, white matter and subcortical areas in the brain. Mental disorder of the case is almost indistinguishable from that of schizophrenia, but the psychotic feature is regarded as an atypical or mixed organic brain syndrome according to the classification in the third edition of the American Psychiatric Association's Diagnostic and Statistical Manual of Mental Disorders (DSM-III). Images PMID:3264568

  2. Extrapulmonary Findings and Malignancies in Participants Screened With Chest CT in the National Lung Screening Trial.

    PubMed

    Nguyen, Xuan V; Davies, Louise; Eastwood, James D; Hoang, Jenny K

    2017-03-01

    The aim of this study was to measure the prevalence of clinically significant extrapulmonary findings on chest CT for lung cancer screening in the National Lung Screening Trial (NLST). Prospectively acquired data on 17,309 participants who underwent low-dose screening chest CT from August 2002 through September 2007 during the NLST were retrospectively analyzed for extrapulmonary findings. NLST radiologist readers coded such findings as "minor" or "potentially significant." On the basis of review of recorded text descriptions, extrapulmonary findings were assigned to five organ groupings (cardiovascular, thyroid, adrenal, renal, and hepatobiliary). Extrapulmonary malignancies diagnosed during screening were also identified from medical and vital status records in the same population. The prevalence rates of organ-specific findings and newly diagnosed extrapulmonary malignancies were calculated. Exemption from human subjects research review was obtained. Extrapulmonary findings were noted in 58.7% of CT-screened participants, and 19.6% had findings coded as potentially significant. The prevalence of potentially significant abnormalities was highest for cardiovascular findings (8.5%), followed by renal (2.4%), hepatobiliary (2.1%), adrenal (1.2%), and thyroid (0.6%) findings. Sixty-seven of 17,309 participants (0.39%) had primary extrathoracic cancers diagnosed during screening. The prevalence of cancers among screened participants was 0.26% (n = 45) for kidney, 0.08% (n = 14) for thyroid, and 0.05% (n = 8) for liver cancers. One in five patients screened with CT for lung cancer will have extrapulmonary findings potentially requiring further evaluation. Indiscriminate workups of incidental extrapulmonary findings could place a significant burden on the health care system with little benefit because extrapulmonary malignancies diagnosed during screening are uncommon. Radiologists reporting screening CT should be familiar with existing recommendations for

  3. Visual-search model observer for assessing mass detection in CT

    NASA Astrophysics Data System (ADS)

    Karbaschi, Zohreh; Gifford, Howard C.

    2017-03-01

    Our aim is to devise model observers (MOs) to evaluate acquisition protocols in medical imaging. To optimize protocols for human observers, an MO must reliably interpret images containing quantum and anatomical noise under aliasing conditions. In this study of sampling parameters for simulated lung CT, the lesion-detection performance of human observers was compared with that of visual-search (VS) observers, a channelized nonprewhitening (CNPW) observer, and a channelized Hoteling (CH) observer. Scans of a mathematical torso phantom modeled single-slice parallel-hole CT with varying numbers of detector pixels and angular projections. Circular lung lesions had a fixed radius. Twodimensional FBP reconstructions were performed. A localization ROC study was conducted with the VS, CNPW and human observers, while the CH observer was applied in a location-known ROC study. Changing the sampling parameters had negligible effect on the CNPW and CH observers, whereas several VS observers demonstrated a sensitivity to sampling artifacts that was in agreement with how the humans performed.

  4. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    PubMed

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  5. Non-perforated peptic ulcer disease: multidetector CT findings, complications, and differential diagnosis.

    PubMed

    Tonolini, Massimo; Ierardi, Anna Maria; Bracchi, Elena; Magistrelli, Paolo; Vella, Adriana; Carrafiello, Gianpaolo

    2017-10-01

    Despite availability of effective therapies, peptic ulcer disease (PUD) remains a major global disease, resulting from a combination of persistent Helicobacter pylori infection and widespread use of nonsteroidal anti-inflammatory drugs. Albeit endoscopy definitely represents the mainstay diagnostic technique, patients presenting to emergency departments with unexplained abdominal pain generally undergo multidetector CT as an initial investigation. Although superficial ulcers generally remain inconspicuous, careful multiplanar CT interpretation may allow to detect deep ulcers, secondary mural and extraluminal signs of peptic gastroduodenitis, thereby allowing timely endoscopic verification and appropriate treatment. This pictorial essay aims to provide radiologists with an increased familiarity with CT diagnosis of non-perforated PUD, with emphasis on differential diagnosis. Following an overview of current disease epidemiology and complications, it explains the appropriate CT acquisition and interpretation techniques, and reviews with several examples the cross-sectional findings of uncomplicated PUD. Afterwards, the CT features of PUD complications such as ulcer haemorrhage, gastric outlet obstruction, biliary and pancreatic fistulisation are presented. • Gastric and duodenal peptic ulcers are increasingly caused by nonsteroidal anti-inflammatory drugs • Multiplanar CT interpretation allows detecting deep ulcers and secondary signs of gastroduodenitis • CT diagnosis of uncomplicated peptic disease relies on direct and indirect signs • Currently the commonest complication, haemorrhage may be treated with transarterial embolisation • Other uncommon complications include gastric outlet obstruction and biliopancreatic fistulisation.

  6. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    PubMed Central

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P < .001) and positive smoking history (P = .001) were associated with increased likelihood of a recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in

  7. Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leng, Shuai; Yu, Lifeng; Zhang, Yi

    2013-08-15

    Purpose: The purpose of this study was to investigate the correlation between model observer and human observer performance in CT imaging for the task of lesion detection and localization when the lesion location is uncertain.Methods: Two cylindrical rods (3-mm and 5-mm diameters) were placed in a 35 × 26 cm torso-shaped water phantom to simulate lesions with −15 HU contrast at 120 kV. The phantom was scanned 100 times on a 128-slice CT scanner at each of four dose levels (CTDIvol = 5.7, 11.4, 17.1, and 22.8 mGy). Regions of interest (ROIs) around each lesion were extracted to generate imagesmore » with signal-present, with each ROI containing 128 × 128 pixels. Corresponding ROIs of signal-absent images were generated from images without lesion mimicking rods. The location of the lesion (rod) in each ROI was randomly distributed by moving the ROIs around each lesion. Human observer studies were performed by having three trained observers identify the presence or absence of lesions, indicating the lesion location in each image and scoring confidence for the detection task on a 6-point scale. The same image data were analyzed using a channelized Hotelling model observer (CHO) with Gabor channels. Internal noise was added to the decision variables for the model observer study. Area under the curve (AUC) of ROC and localization ROC (LROC) curves were calculated using a nonparametric approach. The Spearman's rank order correlation between the average performance of the human observers and the model observer performance was calculated for the AUC of both ROC and LROC curves for both the 3- and 5-mm diameter lesions.Results: In both ROC and LROC analyses, AUC values for the model observer agreed well with the average values across the three human observers. The Spearman's rank order correlation values for both ROC and LROC analyses for both the 3- and 5-mm diameter lesions were all 1.0, indicating perfect rank ordering agreement of the figures of merit (AUC) between

  8. Pulmonary Aspergillus chest wall involvement in chronic granulomatous disease: CT and MRI findings.

    PubMed

    Kawashima, A; Kuhlman, J E; Fishman, E K; Tempany, C M; Magid, D; Lederman, H M; Winkelstein, J A; Zerhouni, E A

    1991-01-01

    Pulmonary Aspergillus infection in patients with chronic granulomatous disease tends to involve the chest wall and consequently carries a high mortality rate. We report the findings of computed tomography (CT) and magnetic resonance imaging (MRI) in three such cases. One patient underwent both CT and MRI, one, CT only, and one, MRI only. In all three, both CT and MRI demonstrated pulmonary consolidations with direct extension to the adjacent chest wall. In both patients who were examined by CT, scans revealed permeative osteolytic changes of adjacent rib or spine compatible with osteomyelitis. In both patients who were examined by MRI, adjacent chest wall involvement was depicted on T1-weighted images and showed increased signal intensity on T2-weighted images. In one of these patients, the chest wall lesion was well defined on T2-weighted images, an appearance compatible with abscess. Epidural extension was demonstrated on MRI in the other patient, who later developed paraparesis. We suggest that CT and MRI have a complementary role in evaluating chest wall invasion by pulmonary Aspergillus infection in chronic granulomatous disease.

  9. Three-dimensional CT enterography using oral gastrografin in patients with small bowel obstruction: comparison with axial CT images or fluoroscopic findings.

    PubMed

    Hong, Seong Sook; Kim, Ah Young; Kwon, Seok Beom; Kim, Pyo Nyun; Lee, Moon-Gyu; Ha, Hyun Kwon

    2010-10-01

    To evaluate the feasibility of 3D CT enterography using oral gastrografin in patients with small bowel obstruction (SBO), focusing on improving diagnostic performance as compared with the use of axial CT imagings and fluoroscopic findings. For a 10-month period, 18 patients with known SBO detected clinically and radiologically were enrolled. In all patients, gastrografin was ingested prior to CT enterography. Twelve patients underwent a fluoroscopic examination. Images were randomly assessed for confidence for the level, for the cause of SBO, and for the assessment of the interpretability of each image by two gastrointestinal radiologists. The results were considered statistically significant using the Wilcoxon rank sum test. All patients (100%) well tolerated the administration of oral gastrografin. The use of 3D CT enterography significantly improved diagnostic confidence for the interpretation of the level, cause of SBO, and the assessment of the interpretability of each image as compared with the use of axial CT images (P < 0.05). 3D CT enterography was superior as compared to fluoroscopic examination (P < 0.05). The use of gastrografin for 3D CT enterography is a safe and feasible technique for precise evaluation of known or suspected SBO.

  10. Cerebral, facial, and orbital involvement in Erdheim-Chester disease: CT and MR imaging findings.

    PubMed

    Drier, Aurélie; Haroche, Julien; Savatovsky, Julien; Godenèche, Gaelle; Dormont, Didier; Chiras, Jacques; Amoura, Zahir; Bonneville, Fabrice

    2010-05-01

    To retrospectively review the brain magnetic resonance (MR) imaging and computed tomographic (CT) findings in patients with Erdheim-Chester disease (ECD). The ethics committee required neither institutional review board approval nor informed patient consent for retrospective analyses of the patients' medical records and imaging data. The patients' medical files were retrospectively reviewed in accordance with human subject research protocols. Three neuroradiologists in consensus analyzed the signal intensity, location, size, number, and gadolinium uptake of lesions detected on brain MR images obtained in 33 patients with biopsy-proved ECD. Thirty patients had intracranial, facial bone, and/or orbital involvement, and three had normal neurologic imaging findings. The hypothalamic-pituitary axis was involved in 16 (53%) of the 30 patients, with six (20%) cases of micronodular or nodular masses of the infundibular stalk. Meningeal lesions were observed in seven (23%) patients. Three (10%) patients had bilateral symmetric T2 high signal intensity in the dentate nucleus areas, and five (17%) had multiple intraaxial enhancing masses. Striking intracranial periarterial infiltration was observed in three (10%) patients. Another patient (3%) had a lesion in the lumen of the superior sagittal sinus. Nine (30%) patients had orbital involvement. Twenty-four (80%) patients had osteosclerosis of the facial and/or skull bones. At least two anatomic sites were involved in two-thirds (n = 20) of the patients. Osteosclerosis of the facial bones associated with orbital masses and either meningeal or infundibular stalk masses was seen in eight (27%) patients. Lesions of the brain, meninges, facial bones, and orbits are frequently observed and should be systematically sought on the brain MR and CT images obtained in patients with ECD, even if these patients are asymptomatic. Careful attention should be directed to the periarterial environment.

  11. Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT.

    PubMed

    Barille, M F; Wu, Jim S; McMahon, Colm J

    2014-03-01

    To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. CT findings of persistent pure ground glass opacity: can we predict the invasiveness?

    PubMed

    Liu, Li-Heng; Liu, Ming; Wei, Ran; Jin, Er-Hu; Liu, Yu-Hui; Xu, Liang; Li, Wen-Wu; Huang, Yong

    2015-01-01

    To investigate whether CT findings can predict the invasiveness of persistent cancerous pure ground glass opacity (pGGO) by correlating the CT imaging features of persistent pGGO with pathological changes. Ninety five patients with persistent pGGOs were included. Three radiologists evaluated the morphologic features of these pGGOs at high resolution CT (HRCT). Binary logistic regression was used to assess the association between CT findings and histopathological classification (pre-invasive and invasive groups). Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of diameters. A total of 105 pGGOs were identified. Between pre-invasive (atypical adenomatous hyperplasia, AAH, and adenocarcinoma in situ, AIS) and invasive group (minimally invasive adenocarcinoma, MIA and invasive lung adenocarcinomas, ILA), there were significant differences in diameter, spiculation and vessel dilatation (p<0.05). No difference was found in air-bronchogram, bubble- lucency, lobulated-margin, pleural indentation or vascular convergence (p>0.05). The optimal threshold value of the diameters to predict the invasiveness of pGGO was 12.50mm. HRCT features can predict the invasiveness of persistent pGGO. The pGGO with a diameter more than 12.50mm, presences of spiculation and vessel dilatation are important factors to differentiate invasive adenocarcinoma from pre-invasive cancerous lesions.

  13. CT and US findings of ovarian torsion within an incarcerated inguinal hernia.

    PubMed

    Hyun, Park Mee; Jung, Ah Young; Lee, Yul; Yang, Ik; Yang, Dae Hyun; Hwang, Ji-Young

    2015-02-01

    Inguinal hernia is relatively common in children. Although inguinal hernia is not frequently encountered in girls in comparison to boys, there are occasional cases of uterine or ovarian herniation in female indirect inguinal hernia. Incarcerated ovary in hernia sac has the risk of torsion and strangulation. We present an 8-year-old girl with painful mass in her left groin. With computed tomography (CT) and ultrasonography (US), we made the diagnosis of ovarian strangulation within an incarcerated inguinal hernia. Since ultrasound is primarily used for evaluation of groin mass, CT findings of an incarcerated inguinal hernia is rarely reported.

  14. A case of probable mixed-infection with Clonorchis sinensis and Fasciola sp.: CT and parasitological findings.

    PubMed

    Kim, Tae Yun; Lee, Yun-Sik; Yun, Ji Hye; Kim, Jeong Ju; Choi, Won Hyung; Oh, In Hwan; Song, Hyun Ouk; Chu, Jong Phil

    2010-06-01

    We report here a human case probably mixed-infected with Clonorchis sinensis and Fasciola sp. who was diagnosed by computed tomography (CT) scan, serological findings, and/or fecal examination. The patient was a 43-year-old Korean female and was admitted to Kyung Hee University Hospital with the complaints of fever and abdominal pain. On admission, marked eosinophilia was noted in her peripheral blood. CT scan showed specific lesions for clonorchiasis and fascioliasis in the liver, along with lesions suggestive of amebic abscess. Micro-ELISA revealed positive results for the 2 helminthic infections. Eggs of C. sinensis and trophozoites of Entamoeba histolytica were observed in the stool. Treatment with praziquantel followed by metronidazole and tinidazole reduced abnormalities in the liver and eosinophilia. This is the first case report of a possible co-infection with 2 kinds of liver flukes in the Republic of Korea.

  15. SU-F-207-16: CT Protocols Optimization Using Model Observer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tseng, H; Fan, J; Kupinski, M

    2015-06-15

    Purpose: To quantitatively evaluate the performance of different CT protocols using task-based measures of image quality. This work studies the task of size and the contrast estimation of different iodine concentration rods inserted in head- and body-sized phantoms using different imaging protocols. These protocols are designed to have the same dose level (CTDIvol) but using different X-ray tube voltage settings (kVp). Methods: Different concentrations of iodine objects inserted in a head size phantom and a body size phantom are imaged on a 64-slice commercial CT scanner. Scanning protocols with various tube voltages (80, 100, and 120 kVp) and current settingsmore » are selected, which output the same absorbed dose level (CTDIvol). Because the phantom design (size of the iodine objects, the air gap between the inserted objects and the phantom) is not ideal for a model observer study, the acquired CT images are used to generate simulation images with four different sizes and five different contracts iodine objects. For each type of the objects, 500 images (100 x 100 pixels) are generated for the observer study. The observer selected in this study is the channelized scanning linear observer which could be applied to estimate the size and the contrast. The figure of merit used is the correct estimation ratio. The mean and the variance are estimated by the shuffle method. Results: The results indicate that the protocols with 100 kVp tube voltage setting provides the best performance for iodine insert size and contrast estimation for both head and body phantom cases. Conclusion: This work presents a practical and robust quantitative approach using channelized scanning linear observer to study contrast and size estimation performance from different CT protocols. Different protocols at same CTDIvol setting could Result in different image quality performance. The relationship between the absorbed dose and the diagnostic image quality is not linear.« less

  16. Thoracic computerized tomographic (CT) findings in 2009 influenza A (H1N1) virus infection in Isfahan, Iran

    PubMed Central

    Rostami, Mojtaba; Javadi, Abbas-Ali; Khorvash, Farzin; Mostafavizadeh, Kamyar; Adibi, Atoosa; Babak, Anahita; Ataei, Behrooz; Meidani, Mohsen; Naeini, Alireza Emami; Salehi, Hasan; Avijgan, Majid; Yazdani, Mohammad Reza; Rezaei, Farshid

    2011-01-01

    BACKGROUND: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT) scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1) in an appropriate clinical setting. METHODS: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23rd 2009 to February 20th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1) virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. RESULTS: Patchy infiltration (34.6%), lobar consolidation (30.8%), and interstitial infiltration (26.9%) with airbronchogram (38.5%) were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8%) showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS). CONCLUSIONS: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1) in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific. PMID:22091280

  17. Tuberculous spondylodiscitis in a patient with a sickle-cell disease: CT findings.

    PubMed

    Krupniewski, Leszek; Palczewski, Piotr; Gołębiowski, Marek; Kosińska-Kaczyńska, Katarzyna

    2012-01-01

    Although sickle-cell anemia (SCA) is common in black Americans, Sub-Saharan Africa and in the Mediterranean area, the disease is rare in the temperate climate zone. The manifestations of the disease are related mainly to the production of abnormal hemoglobin that leads to organ ischemia and increased susceptibility to infection caused by functional asplenia. The authors present CT findings in a 39-year-old black woman diagnosed due to abdominal pain, lymphadenopathy and fever. CT of the thorax and abdomen demonstrated changes in the liver, spleen, and skeletal system suggestive of SCA complicated with spondylodiscitis in the thoracic spine. Hepatomegaly and small calcified spleen are typical findings in older homozygotic patients with SCA. The lesions in the skeleton may be related either to intramedullary hematopoiesis or osteonecrosis and osteomyelitis. In the latter case, diffuse osteosclerosis and H-shaped vertebrae are most typical. Tuberculous spondylodiscitis is characterized by the location in the thoracic region, preferential involvement of anterior elements, relative sparing of intervertebral discs, and cold abscesses.

  18. Diagnostic accuracy of the clinical and CT findings for differentiating Kikuchi's disease and tuberculous lymphadenitis presenting with cervical lymphadenopathy.

    PubMed

    Baek, Hye Jin; Lee, Jeong Hyun; Lim, Hyun Kyung; Lee, Ha Young; Baek, Jung Hwan

    2014-11-01

    To determine the optimal clinical and CT findings for differentiating Kikuchi's disease (KD) and tuberculous lymphadenitis (TB) in patients presenting with cervical lymphadenopathy. From 2006 to 2010, 87 consecutive patients who were finally diagnosed with KD or TB were enrolled. Two radiologists performed independent analysis of contrast-enhanced neck CT images with regard to the involvement pattern, nodal or perinodal changes, and evidence of the previous infection. Significant clinical and CT findings of KD were determined by statistical analyses. Of the 87 patients, 27 (31%) were classified as having KD and 60 (69%) as having TB. Statistically significant findings of KD patients were younger age, presence of fever, involvement of ≥5 nodal levels or the bilateral neck, no or minimal nodal necrosis, marked perinodal infiltration, and no evidence of upper lung lesion or mediastinal lymphadenopathy. The presence of four or more statistically significant clinical and CT findings of KD had the largest area under the receiver-operating characteristic curve (A z = 0.861; 95% confidence intervals 0.801, 0.909), with a sensitivity of 89% and specificity of 83%. CT can be a helpful tool for differentiating KD from TB, especially when it is combined with the clinical findings.

  19. Chest CT findings in patients with dysphagia and aspiration: a systematic review

    PubMed Central

    Scheeren, Betina; Gomes, Erissandra; Alves, Giordano; Marchiori, Edson; Hochhegger, Bruno

    2017-01-01

    ABSTRACT The objective of this systematic review was to characterize chest CT findings in patients with dysphagia and pulmonary aspiration, identifying the characteristics and the methods used. The studies were selected from among those indexed in the Brazilian Virtual Library of Health, LILACS, Indice Bibliográfico Español de Ciencias de la Salud, Medline, Cochrane Library, SciELO, and PubMed databases. The search was carried out between June and July of 2016. Five articles were included and reviewed, all of them carried out in the last five years, published in English, and coming from different countries. The sample size in the selected studies ranged from 43 to 56 patients, with a predominance of adult and elderly subjects. The tomographic findings in patients with dysphagia-related aspiration were varied, including bronchiectasis, bronchial wall thickening, pulmonary nodules, consolidations, pleural effusion, ground-glass attenuation, atelectasis, septal thickening, fibrosis, and air trapping. Evidence suggests that chest CT findings in patients with aspiration are diverse. In this review, it was not possible to establish a consensus that could characterize a pattern of pulmonary aspiration in patients with dysphagia, further studies of the topic being needed. PMID:28767772

  20. Chest CT findings in patients with dysphagia and aspiration: a systematic review.

    PubMed

    Scheeren, Betina; Gomes, Erissandra; Alves, Giordano; Marchiori, Edson; Hochhegger, Bruno

    2017-01-01

    The objective of this systematic review was to characterize chest CT findings in patients with dysphagia and pulmonary aspiration, identifying the characteristics and the methods used. The studies were selected from among those indexed in the Brazilian Virtual Library of Health, LILACS, Indice Bibliográfico Español de Ciencias de la Salud, Medline, Cochrane Library, SciELO, and PubMed databases. The search was carried out between June and July of 2016. Five articles were included and reviewed, all of them carried out in the last five years, published in English, and coming from different countries. The sample size in the selected studies ranged from 43 to 56 patients, with a predominance of adult and elderly subjects. The tomographic findings in patients with dysphagia-related aspiration were varied, including bronchiectasis, bronchial wall thickening, pulmonary nodules, consolidations, pleural effusion, ground-glass attenuation, atelectasis, septal thickening, fibrosis, and air trapping. Evidence suggests that chest CT findings in patients with aspiration are diverse. In this review, it was not possible to establish a consensus that could characterize a pattern of pulmonary aspiration in patients with dysphagia, further studies of the topic being needed.

  1. Inter- and intra-observer reliability of measurement of pedicle screw breach assessed by postoperative CT scans.

    PubMed

    Lavelle, William F; Ranade, Ashish; Samdani, Amer F; Gaughan, John P; D'Andrea, Linda P; Betz, Randal R

    2014-01-01

    Pedicle screws are used increasingly in spine surgery. Concerns of complications associated with screw breach necessitates accurate pedicle screw placement. Postoperative CT imaging helps to detect screw malposition and assess its severity. However, accuracy is dependent on the reading of the CT scans. Inter- and intra-observer variability could affect the reliability of CT scans to assess multiple screw types and sites. The purpose of this study was to assess the reliability of multi-observer analysis of CT scans for determining pedicle screw breach for various screw types and sites in patients with spinal deformity or degenerative pathologies. Axial CT scan images of 23 patients (286 screws) were read by four experienced spine surgeons. Pedicle screw placement was considered 'In' when the screw was fully contained and/or the pedicle wall breach was ≤2 mm. 'Out' was defined as a breach in the medial or lateral pedicle wall >2 mm. Intra-class coefficients (ICC) were calculated to assess the inter- and intra-observer reliability. Marked inter- and intra-observer variability was noticed. The overall inter-observer ICC was 0.45 (95% confidence limits 0.25 to 0.65). The intra-observer ICC was 0.49 (95% confidence limits 0.29 to 0.69). Underlying spinal pathology, screw type, and patient age did not seem to impact the reliability of our CT assessments. Our results indicate the evaluation of pedicle screw breach on CT by a single surgeon is highly variable, and care should be taken when using individual CT evaluations of millimeters of breach as a basis for screw removal. This was a Level III study.

  2. Clinical utility of FDG PET/CT in acute complicated pyelonephritis-results from an observational study.

    PubMed

    Wan, Chih-Hsing; Tseng, Jing-Ren; Lee, Ming-Hsun; Yang, Lan-Yan; Yen, Tzu-Chen

    2018-03-01

    Acute complicated pyelonephritis (ACP) is an upper urinary tract infection associated with coexisting urinary tract abnormalities or medical conditions that could predispose to serious outcomes or treatment failures. Although CT and magnetic resonance imaging (MRI) are frequently used in patients with ACP, the clinical value of 18 F-fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) has not been systematically investigated. This single-center retrospective study was designed to evaluate the potential usefulness of FDG PET/CT in patients with ACP. Thirty-one adult patients with ACP who underwent FDG PET/CT were examined. FDG PET/CT imaging characteristics, including tracer uptake patterns, kidney volumes, and extrarenal imaging findings, were reviewed in combination with clinical data and conventional imaging results. Of the 31 patients, 19 (61%) showed focal FDG uptake. The remaining 12 study participants showed a diffuse FDG uptake pattern. After volumetric approximation, the affected kidneys were found to be significantly enlarged. Patients who showed a focal uptake pattern had a higher frequency of abscess formation requiring drainage. ACP patients showing diffuse tracer uptake patterns had a more benign clinical course. Seven patients had suspected extrarenal coinfections, and FDG PET/CT successfully confirmed the clinical suspicion in five cases. FDG PET/CT was as sensitive as CT in identifying the six patients (19%) who developed abscesses. Notably, FDG PET/CT findings caused a modification to the initial antibiotic regimen in nine patients (29%). FDG PET/CT may be clinically useful in the assessment of patients with ACP who have a progressive disease course.

  3. CT findings of a unicameral calcaneal bone cyst containing a fluid-fluid level.

    PubMed

    Gallagher, Thomas A; Lim-Dunham, Jennifer E; Vade, Aruna

    2007-03-01

    Calcaneal unicameral bone cysts often contain fluid, but rarely contain fluid-fluid levels. We present a case focusing on the CT findings of a large calcaneal bone cyst with a fluid-fluid level and a review of the literature.

  4. CT findings associated with blastic plasmacytoid dendritic cell neoplasm: a case report

    PubMed Central

    Choi, Jung W; Jeong, Katherine; Sokol, Lubomir

    2016-01-01

    Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is a rare hematologic malignancy that is frequently misdiagnosed. We present a case of a 53-year-old man diagnosed with blastic plasmacytoid dendritic cell neoplasm with extensive computed tomography (CT) findings and provide an imaging focused review of this uncommon malignancy. PMID:27504192

  5. Multidetector CT of expected findings and complications after contemporary inguinal hernia repair surgery

    PubMed Central

    Tonolini, Massimo

    2016-01-01

    Inguinal hernia repair (IHR) with prosthetic mesh implantation is the most common procedure in general surgery, and may be performed using either an open or laparoscopic approach. This paper provides an overview of contemporary tension-free IHR techniques and materials, and illustrates the expected postoperative imaging findings and iatrogenic injuries. Emphasis is placed on multidetector CT, which represents the ideal modality to comprehensively visualize the operated groin region and deeper intra-abdominal structures. CT consistently depicts seroma, mesh infections, hemorrhages, bowel complications and urinary bladder injuries, and thus generally provides a consistent basis for therapeutic choice. Since radiologists are increasingly requested to investigate suspected iatrogenic complications, this paper aims to provide an increased familiarity with early CT studies after IHR, including complications and normal postoperative appearances such as focal pseudolesions, in order to avoid misinterpretation and inappropriate management. PMID:27460285

  6. [A case of pycnodysostosis--observation of the skull by CT scan].

    PubMed

    Anegawa, S; Bekki, Y; Furukawa, Y; Yokota, S; Torigoe, R

    1987-07-01

    A 13-year-old boy was presented to the Department of Neurosurgery, Saiseikai Fukuoka General Hospital for further examinations concerning abnormal findings in the skull radiogram taken when he struck his head. His physical features showed some characteristics the same as those of pycnodysostosis as follows--proportionate dwarfism, prominent forehead, short spoon-shaped fingers, bilateral exophthalmos. A skull radiogram revealed widely open cranial sutures with no healing of the fracture and craniotomy which was performed for an acute epidural hematoma 6 years ago. Furthermore, the mandible was hypoplastic with a virtual loss of mandibular angle. CT of the soft tissues showed somewhat dilated cortical sulci and ventricles without any structural abnormalities in the brain. CT of bone algorithm revealed specific characteristics of this disease. The paranasal sinuses were quite hypoplastic. Especially in the maxillary sinuses, frontal sinuses and mastoid air cells, none of developments of sinuses were noted, even though the middle and internal ear seemed to be normal. Moreover, the ethmoid and sphenoid sinuses were noted, although their developments were poor. The appearance of skull base was normal, including the inlets and outlets of cranial nerves or vessels and synchondroses. However, the density of the skull base, especially in the diploe, was higher than normal in Hansfield number. Furthermore, detailed measurements of skull base demonstrated that the skull base itself was also dwarfism. Pycnodysostosis is a generalized skeletal disease whose cardinal features are moderate generalized osteosclerosis and dwarfism. However, the detailed observation on the cranium by CT has not been reported. In our study, the development of sinuses in bones with intramembranous ossification are worse than that with endochondral ossification.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. A simple method for low-contrast detectability, image quality and dose optimisation with CT iterative reconstruction algorithms and model observers.

    PubMed

    Bellesi, Luca; Wyttenbach, Rolf; Gaudino, Diego; Colleoni, Paolo; Pupillo, Francesco; Carrara, Mauro; Braghetti, Antonio; Puligheddu, Carla; Presilla, Stefano

    2017-01-01

    The aim of this work was to evaluate detection of low-contrast objects and image quality in computed tomography (CT) phantom images acquired at different tube loadings (i.e. mAs) and reconstructed with different algorithms, in order to find appropriate settings to reduce the dose to the patient without any image detriment. Images of supraslice low-contrast objects of a CT phantom were acquired using different mAs values. Images were reconstructed using filtered back projection (FBP), hybrid and iterative model-based methods. Image quality parameters were evaluated in terms of modulation transfer function; noise, and uniformity using two software resources. For the definition of low-contrast detectability, studies based on both human (i.e. four-alternative forced-choice test) and model observers were performed across the various images. Compared to FBP, image quality parameters were improved by using iterative reconstruction (IR) algorithms. In particular, IR model-based methods provided a 60% noise reduction and a 70% dose reduction, preserving image quality and low-contrast detectability for human radiological evaluation. According to the model observer, the diameters of the minimum detectable detail were around 2 mm (up to 100 mAs). Below 100 mAs, the model observer was unable to provide a result. IR methods improve CT protocol quality, providing a potential dose reduction while maintaining a good image detectability. Model observer can in principle be useful to assist human performance in CT low-contrast detection tasks and in dose optimisation.

  8. Accuracy of Canadian CT head rule in predicting positive findings on CT of the head of patients after mild head injury in a large trauma centre in Saudi Arabia

    PubMed Central

    Arab, Ala Faisal; Ahmed, Anwar E; Hussein, Mohamed Ahmed; Khankan, Azzam A; Alokaili, Riyadh Nasser

    2015-01-01

    Background Investigation of unjustified computed tomography (CT) scan in patients with minor head injury is lacking in Saudi Arabia. The purpose of the study was to evaluate the compliance and effectiveness of the Canadian computed tomography head rule (CCHR) in our emergency department (ED) and trauma centre and also to reduce the number of unjustified CT studies of the head in the centre. Methods A retrospective study of 368 ED patients with minor head injury was conducted. Patients who underwent CT scan between July 2010 and June 2011were selected from the ED head trauma registry by systematic randomisation. The CCHR was retrospectively applied on the patients’ charts to calculate the prevalence of unjustified head CT scans. A separate survey was conducted to evaluate three emergency physicians’ level of awareness about the CCHR and their ability to determine the necessity of CT scans with various clinical scenarios of head injury. Results The prevalence of unjustified CT scans as per the CCHR was 61.8% (95% confidence interval (CI) 56.5–66.9%). Approximately 5% of the sample had positive CT findings with 95% CI 2.9–7.6%. The CCHR correctly identified 12 cases with positive CT findings with 66.67% sensitivity. Only 24 (6.7%) had Glasgow coma scale scores less than 15 (13/14). The Glasgow coma scale correctly identified only two cases with positive CT findings with 11.11% sensitivity. The percentage of skull fracture (0.9% vs 5%, P = 0.030) was significantly lower in patients with unjustified CT scans than in patients with clinically justified CT scans. There was fair to substantial agreement between the ED physicians and the CCHR (κ = 35–61%). Two ED physicians identified all cases of justified CT scan with 100% sensitivity (95% CI 71.51–100%). Conclusion The level of education regarding the CCHR was found to be optimal among emergency physicians using a case-based scenario survey. The CCHR was found to have a poor compliance potential in

  9. F-18 FDG PET/CT findings of a case of sacral nerve root neurolymphomatosis that occurred during chemotherapy.

    PubMed

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Matsunaga, Naofumi; Yujiri, Toshiaki; Nakazora, Tatsuki; Ariyoshi, Kouichi

    2011-01-01

    Neurolymphomatosis (NL) is a rare, unique subtype of lymphomatous infiltration of peripheral nerves. Clinical/radiologic diagnosis of NL is challenging. We report F-18 FDG PET/CT findings of a case of breast diffuse large B-cell lymphoma, in which NL developed regardless of regression of systemic lesions during induction chemotherapy. FDG PET/CT showed characteristic findings of well-demarcated, linear abnormal FDG uptake along a sacral vertebral foramen, leading to diagnosis of NL, with the finding of thickened nerve roots on magnetic resonance imaging. Altered chemotherapeutic regimen resulted in disappearance of these abnormal FDG uptake, with recovery of neurologic symptoms. Peripheral nerve NL may occur during chemotherapy, and FDG PET/CT can be a useful imaging modality in diagnosis and monitoring of therapeutic response of this disease.

  10. X-Ray Micro-CT Observations of Hydrate Pore Habit and Lattice Boltzmann Simulations on Permeability Evolution in Hydrate Bearing Sediments (HBS)

    NASA Astrophysics Data System (ADS)

    Chen, X.; Espinoza, N.; Verma, R.; Prodanovic, M.

    2017-12-01

    We use X-ray micro-computed tomography (μCT) to observe xenon hydrate growth. During xenon hydrate formation in a single pore and a sandpack, we observe heterogeneous (patchy) hydrate distribution at both pore (10 μm) and core scales (10 cm). These results present similarities with earlier observations on naturally occurring and synthetic hydrate-bearing sediment (HBS). Based on image analyses of xenon hydrate in the single pore, we find that, under the quasi-isothermal condition, the xenon volumetric growth rate versus overpressurization curve fits an Arrhenius type equation. Using the μCT images of HBS, we are able to calculate the permeability of HBS using a lattice Boltzmann method. We find the reduced permeability versus hydrate saturation curve fits a simple Corey-type model as suggested by earlier studies. However, patchy distribution of hydrate does not permit a straightforward interpretation of the saturation exponent. This work provides fundamental observations of hydrate growth and pore habit in sediments and how hydrate habit affects the hydraulic conductivity of HBS. Further implications can be extended to the strength, seismic velocities and electrical properties of HBS.

  11. A Comparison between 18F-FDG PET/CT Imaging and Biological and Radiological Findings in Restaging of Hepatoblastoma Patients

    PubMed Central

    Treglia, Giorgio; Pagano, Manuela; Fania, Piercarlo; Basso, Maria Eleonora; Fagioli, Franca; Ficola, Umberto

    2013-01-01

    Background. In this study we retrospectively evaluated if 18F-FDG-PET/CT provided incremental diagnostic information over CI in a group of hepatoblastoma patients performing restaging. Procedure. Nine patients (mean age: 5.9 years; range: 3.1–12 years) surgically treated for hepatoblastoma were followed up by clinical examination, serum α-FP monitoring, and US. CI (CT or MRI) and PET/CT were performed in case of suspicion of relapse. Fine-needle aspiration biopsies (FNAB) were carried out for final confirmation if the results of CI, PET/CT, and/or α-FP levels were suggestive of relapse. PET/CT and CI findings were analyzed for comparison purposes, using FNAB as reference standard. Results. α-FP level was suggestive of disease recurrence in 8/9 patients. Biopsy was performed in 8/9 cases. CI and PET/CT resulted to be concordant in 5/9 patients (CI identified recurrence of disease, but 18F-FDG-PET/CT provided a better definition of disease extent); in 4/9 cases, CI diagnostic information resulted in negative findings, whereas PET/CT correctly detected recurrence of disease. 18F-FDG-PET/CT showed an agreement of 100% (8/8) with FNAB results. Conclusions. 18F-FDG-PET/CT scan seems to better assess HB patients with respect to CI and may provide incremental diagnostic value in the restaging of this group of patients. PMID:24063012

  12. Differential CT Attenuation of Metabolically Active and Inactive Adipose Tissues — Preliminary Findings

    PubMed Central

    Hu, Houchun H.; Chung, Sandra A.; Nayak, Krishna S.; Jackson, Hollie A.; Gilsanz, Vicente

    2010-01-01

    This study investigates differences in CT Hounsfield units (HUs) between metabolically active (brown fat) and inactive adipose tissues (white fat) due to variations in their densities. PET/CT data from 101 pediatric and adolescent patients were analyzed. Regions of metabolically active and inactive adipose tissues were identified and standard uptake values (SUVs) and HUs were measured. HUs of active brown fat were more positive (p<0.001) than inactive fat (−62.4±5.3 versus −86.7±7.0) and the difference was observed in both males and females. PMID:21245691

  13. Utility of CT Findings in the Diagnosis of Cecal Volvulus.

    PubMed

    Dane, Bari; Hindman, Nicole; Johnson, Evan; Rosenkrantz, Andrew B

    2017-10-01

    The objective of our study was to assess the utility of CT features in the diagnosis of cecal volvulus. Forty-three patients undergoing CT for cecal volvulus and with surgical or clinical follow-up were included. Two radiologists (11 years and 1 year of experience) evaluated CT examinations for the following: whirl sign, abnormal cecal position, "bird beak" sign, severe cecal distention, mesenteric engorgement, a newly described "central appendix" sign (defined as abnormal appendix position near midline), and overall impression for cecal volvulus. Univariable and multivariable assessments were performed. Patients with CT examinations in which the appendix was not visible were excluded from calculations involving the central appendix sign. Fifty-one percent (n = 22) of patients had cecal volvulus. All CT findings were significantly more common in patients with cecal volvulus (p < 0.01) other than mesenteric engorgement for reader 1 (p = 0.332). Readers 1 and 2 identified the central appendix sign in 92.9% and 92.3% of patients with volvulus versus in 37.5 and 31.1% of patients without volvulus. The whirl sign exhibited a sensitivity for cecal volvulus of 90.9% for reader 1 and 95.5% for reader 2, and a specificity of 61.9% for both readers. Abnormal cecal position exhibited a sensitivity of 90.0% for reader 1 and 100.0% for reader 2 and a specificity of 66.7% and 38.1%. The bird beak sign exhibited a sensitivity of 86.4% for reader 1 and 100.0% for reader 2 and a specificity of 85.7% and 71.4%. Severe cecal distention exhibited a sensitivity of 100.0% for both readers and a specificity of 81.0% and 61.9%. Mesenteric engorgement exhibited a sensitivity of 40.9% for reader 1 and 100.0% for reader 2 and a specificity of 76.2% and 71.4%. The central appendix sign exhibited a sensitivity of 92.9% for reader 1 and 92.3% for reader 2 and a specificity of 62.5% and 68.8%. Overall impression exhibited a sensitivity of 100.0% for both readers and a specificity of 76.2% and 57

  14. Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

    PubMed

    Yu, Lifeng; Chen, Baiyu; Kofler, James M; Favazza, Christopher P; Leng, Shuai; Kupinski, Matthew A; McCollough, Cynthia H

    2017-08-01

    interval (CI): 0.919 to 0.990] and with the CHO_MS performance in the multislice viewing mode (R = 0.952, 95% CI: 0.865 to 0.984). The CHO_2D performance, calculated from the 2D viewing mode, also had a strong correlation with human observer performance in the multislice viewing mode (R = 0.957, 95% CI: 879 to 0.985). Human observer performance varied between the multislice and 2D modes. One reader performed better in the multislice mode (P = 0.013); whereas the other two readers showed no significant difference between the two viewing modes (P = 0.057 and P = 0.38). A 2D CHO model is highly correlated with human observer performance in detecting spherical low contrast objects in multislice viewing of CT images. This finding provides some evidence for the use of a simpler, 2D CHO to assess image quality in clinically relevant CT tasks where multislice viewing is used. © 2017 American Association of Physicists in Medicine.

  15. Assessing the prevalence and clinical relevance of positive abdominal and pelvic CT findings in senior patients presenting to the emergency department.

    PubMed

    Alabousi, Abdullah; Patlas, Michael N; Meshki, Malek; Monteiro, Sandra; Katz, Douglas S

    2016-04-01

    The purpose of our study was to retrospectively evaluate the prevalence and clinical relevance of positive abdominal and pelvic CT findings for patients 65 years of age and older, when compared with all other scanned adult Emergency Department (ED) patients, at a single tertiary care hospital. Our hypothesis was that there is an increased prevalence and clinical relevance of positive abdominal/pelvic CT findings in senior patients. A research ethics board-approved retrospective review of all adult patients who underwent an emergency CT of the abdomen and pelvis for acute nontraumatic abdominal and/or pelvic signs and symptoms was performed. Two thousand one hundred two patients between October 1, 2011, and September 30, 2013, were reviewed. Six hundred thirty-one patients were included in the <65 group (298 men and 333 women; mean age 46, age range 18-64), and 462 were included in the >65 group (209 men and 253 women; mean age 77.6, age range 65-99). Overall, there were more positive CT findings for patients <65 (389 positive cases, 61.6 %) compared with the >65 group (257 positive cases, 55.6 %), which was a statistically significant difference (p < 0.03). Moreover, with the exception of complicated appendicitis cases, which were more common in the >65 group, there were no statistically significant differences in the clinical/surgical relevance of the positive CT findings between the two groups. The findings of our retrospective study therefore refute our hypothesis that there is an increased prevalence of positive abdominal CT findings in patients >65. This may be related to ED physicians at our institution being more hesitant to order CT examinations for the younger population, presumably due to radiation concerns. However, older patients in our series were more likely to present with complicated appendicitis, and a lower threshold for ordering CT examinations of the abdomen and pelvis in this patient population should therefore be considered.

  16. Gorlin-Goltz syndrome: incidental finding on routine ct scan following car accident

    PubMed Central

    2009-01-01

    Introduction Gorlin-Goltz syndrome is a rare hereditary disease. Pathogenesis of the syndrome is attributed to abnormalities in the long arm of chromosome 9 (q22.3-q31) and loss or mutations of human patched gene (PTCH1 gene). Multiple basal cell carcinomas (BCCs), odontogenic keratocysts, skeletal abnormalities, hyperkeratosis of palms and soles, intracranial ectopic calcifications of the falx cerebri and facial dysmorphism are considered the main clinical features. Diagnosis is based upon established major and minor clinical and radiological criteria and ideally confirmed by DNA analysis. Because of the different systems affected, a multidisciplinary approach team of various experts is required for a successful management. Case presentation We report the case of a 19 year-old female who was involved in a car accident and found to present imaging findings of Gorlin-Goltz syndrome during a routine whole body computed tomography (CT) scan in order to exclude traumatic injuries. Conclusion Radiologic findings of the syndrome are easily identifiable on CT scans and may prompt to early verification of the disease, which is very important for regular follow-up and better survival rates from the co-existent diseases. PMID:20062724

  17. Gorlin-Goltz syndrome: incidental finding on routine ct scan following car accident.

    PubMed

    Kalogeropoulou, Christina; Zampakis, Petros; Kazantzi, Santra; Kraniotis, Pantelis; Mastronikolis, Nicholas S

    2009-11-25

    Gorlin-Goltz syndrome is a rare hereditary disease. Pathogenesis of the syndrome is attributed to abnormalities in the long arm of chromosome 9 (q22.3-q31) and loss or mutations of human patched gene (PTCH1 gene). Multiple basal cell carcinomas (BCCs), odontogenic keratocysts, skeletal abnormalities, hyperkeratosis of palms and soles, intracranial ectopic calcifications of the falx cerebri and facial dysmorphism are considered the main clinical features. Diagnosis is based upon established major and minor clinical and radiological criteria and ideally confirmed by DNA analysis. Because of the different systems affected, a multidisciplinary approach team of various experts is required for a successful management. We report the case of a 19 year-old female who was involved in a car accident and found to present imaging findings of Gorlin-Goltz syndrome during a routine whole body computed tomography (CT) scan in order to exclude traumatic injuries. Radiologic findings of the syndrome are easily identifiable on CT scans and may prompt to early verification of the disease, which is very important for regular follow-up and better survival rates from the co-existent diseases.

  18. High prevalence of bronchiectasis in adults: analysis of CT findings in a health screening program.

    PubMed

    Kwak, Hyun Jung; Moon, Ji-Yong; Choi, Yo Won; Kim, Tae Hyung; Sohn, Jang Won; Yoon, Ho Joo; Shin, Dong Ho; Park, Sung Soo; Kim, Sang-Heon

    2010-12-01

    Bronchiectasis is one of the common chronic respiratory diseases and associated with respiratory morbidity and mortality. However, neither its prevalence nor its etiology is well-defined. We aimed to estimate the prevalence and risk factors of bronchiectasis in adults. In a retrospective study, we analyzed radiologic findings on chest computed tomography (CT) images performed as part of a health-screening program. From January to December 2008, 1,409 (24.6%) of 5,727 participants in the screening program of a health promotion center at a university hospital underwent chest CT scans based on the subject's decision. Bronchiectasis was diagnosed, if there was abnormal bronchial dilatation in any area of both lungs on chest CT. Respiratory symptoms, smoking status, and past medical history were also analyzed to define clinical characteristics and risk factors of bronchiectasis. Of 1,409 patients (aged 23-86 years), who were screened for respiratory diseases using chest CT for one year in a health promotion center, 129 patients (9.1%) were diagnosed with bronchiectasis. The prevalence of bronchiectasis was higher in females than in males (11.5% vs. 7.9%, p = 0.022) and increased with age. Respiratory symptoms were reported in 53.7% of subjects. Previous history of tuberculosis (TB) (OR 4.61, 95% CI 2.39-8.88, p = 0.001) and age (OR 2.49, 95% CI 1.56-3.98, p = 0.001) were significantly associated with bronchiectasis. This retrospective analysis of chest CT findings in health screening examinees revealed a very high prevalence of bronchiectasis in adults. Previous TB infection is one of the major causes of bronchiectasis.

  19. Chest CT scan findings in World Trade Center workers.

    PubMed

    de la Hoz, Rafael E; Weber, Jonathan; Xu, Dongming; Doucette, John T; Liu, Xiaoyu; Carson, Deborah A; Celedón, Juan C

    2018-03-15

    We examined the chest CT scans of 1,453 WTC responders using the International Classification of High-resolution CT for Occupational and Environmental Respiratory Diseases. Univariate and bivariate analyses of potential work-related pleural abnormalities were performed with pre-WTC and WTC-related occupational exposure data, spirometry, demographics and quantitative CT measurements. Logistic regression was used to evaluate occupational predictors of those abnormalities. Chest CT scans were performed first at a median of 6.8 years after 9/11/2001. Pleural abnormalities were the most frequent (21.1%) across all occupational groups In multivariable analyses, significant pre-WTC occupational asbestos exposure, and work as laborer/cleaner were predictive of pleural abnormalities, with prevalence being highest for the Polish subgroup (n = 237) of our population. Continued occupational lung disease surveillance is warranted in this cohort.

  20. Renal carcinomas associated with Xp11.2 translocations: are CT findings suggestive of the diagnosis?

    PubMed

    He, J; Huan, Y; Qiao, Q; Zhang, J; Zhang, J S

    2014-01-01

    The purpose of the present study was to summarize the computed tomography (CT) features of renal carcinomas associated with Xp11.2 translocations, and determine whether the diagnosis can be reliably deduced from imaging findings. Radiological studies of six patients (aged from 9-29 years) with renal carcinoma associated with Xp11.2 translocations were retrospectively analysed. The tumours varied in size from 3.3-11 cm (mean 5.4 cm). Unenhanced CT and cortical, medullary, and pelvic-phase contrast-enhanced CT imaging was undertaken in all cases. Unenhanced CT revealed that tumours had a relatively increased radiodensity (4/6, ranged from 45-60 HU) and suggested the possibility of diffuse haemorrhage. Three of the six cases showed irregular and boundary calcification of the lesion. Contrast-enhanced CT showed relatively well demarcated tumours with heterogeneous enhancement (6/6). Prolonged enhancement of tumours might be a common sign (6/6) in Xp11.2 translocations. Three out of the six cases were combined with retroperitoneal lymph nodes metastasis. Renal carcinomas associated with Xp11.2 translocations should be considered, particularly in children and young patients, when the lesion has calcification and is hyper-dense on unenhanced CT, and has prolonged enhancement on contrast-enhanced images. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Derivation and Validation of Two Decision Instruments for Selective Chest CT in Blunt Trauma: A Multicenter Prospective Observational Study (NEXUS Chest CT)

    PubMed Central

    Rodriguez, Robert M.; Langdorf, Mark I.; Nishijima, Daniel; Baumann, Brigitte M.; Hendey, Gregory W.; Medak, Anthony J.; Raja, Ali S.; Allen, Isabel E.; Mower, William R.

    2015-01-01

    Background Unnecessary diagnostic imaging leads to higher costs, longer emergency department stays, and increased patient exposure to ionizing radiation. We sought to prospectively derive and validate two decision instruments (DIs) for selective chest computed tomography (CT) in adult blunt trauma patients. Methods and Findings From September 2011 to May 2014, we prospectively enrolled blunt trauma patients over 14 y of age presenting to eight US, urban level 1 trauma centers in this observational study. During the derivation phase, physicians recorded the presence or absence of 14 clinical criteria before viewing chest imaging results. We determined injury outcomes by CT radiology readings and categorized injuries as major or minor according to an expert-panel-derived clinical classification scheme. We then employed recursive partitioning to derive two DIs: Chest CT-All maximized sensitivity for all injuries, and Chest CT-Major maximized sensitivity for only major thoracic injuries (while increasing specificity). In the validation phase, we employed similar methodology to prospectively test the performance of both DIs. We enrolled 11,477 patients—6,002 patients in the derivation phase and 5,475 patients in the validation phase. The derived Chest CT-All DI consisted of (1) abnormal chest X-ray, (2) rapid deceleration mechanism, (3) distracting injury, (4) chest wall tenderness, (5) sternal tenderness, (6) thoracic spine tenderness, and (7) scapular tenderness. The Chest CT-Major DI had the same criteria without rapid deceleration mechanism. In the validation phase, Chest CT-All had a sensitivity of 99.2% (95% CI 95.4%–100%), a specificity of 20.8% (95% CI 19.2%–22.4%), and a negative predictive value (NPV) of 99.8% (95% CI 98.9%–100%) for major injury, and a sensitivity of 95.4% (95% CI 93.6%–96.9%), a specificity of 25.5% (95% CI 23.5%–27.5%), and a NPV of 93.9% (95% CI 91.5%–95.8%) for either major or minor injury. Chest CT-Major had a sensitivity

  2. Whole-body nonenhanced PET/MR versus PET/CT in the staging and restaging of cancers: preliminary observations.

    PubMed

    Huellner, Martin W; Appenzeller, Philippe; Kuhn, Félix P; Husmann, Lars; Pietsch, Carsten M; Burger, Irene A; Porto, Miguel; Delso, Gaspar; von Schulthess, Gustav K; Veit-Haibach, Patrick

    2014-12-01

    To assess the diagnostic performance of whole-body non-contrast material-enhanced positron emission tomography (PET)/magnetic resonance (MR) imaging and PET/computed tomography (CT) for staging and restaging of cancers and provide guidance for modality and sequence selection. This study was approved by the institutional review board and national government authorities. One hundred six consecutive patients (median age, 68 years; 46 female and 60 male patients) referred for staging or restaging of oncologic malignancies underwent whole-body imaging with a sequential trimodality PET/CT/MR system. The MR protocol included short inversion time inversion-recovery ( STIR short inversion time inversion-recovery ), Dixon-type liver accelerated volume acquisition ( LAVA liver accelerated volume acquisition ; GE Healthcare, Waukesha, Wis), and respiratory-gated periodically rotated overlapping parallel lines with enhanced reconstruction ( PROPELLER periodically rotated overlapping parallel lines with enhanced reconstruction ; GE Healthcare) sequences. Primary tumors (n = 43), local lymph node metastases (n = 74), and distant metastases (n = 66) were evaluated for conspicuity (scored 0-4), artifacts (scored 0-2), and reader confidence on PET/CT and PET/MR images. Subanalysis for lung lesions (n = 46) was also performed. Relevant incidental findings with both modalities were compared. Interreader agreement was analyzed with intraclass correlation coefficients and κ statistics. Lesion conspicuity, image artifacts, and incidental findings were analyzed with nonparametric tests. Primary tumors were less conspicuous on STIR short inversion time inversion-recovery (3.08, P = .016) and LAVA liver accelerated volume acquisition (2.64, P = .002) images than on CT images (3.49), while findings with the PROPELLER periodically rotated overlapping parallel lines with enhanced reconstruction sequence (3.70, P = .436) were comparable to those at CT. In distant metastases, the PROPELLER

  3. Reduction of observer variation using matched CT-PET for lung cancer delineation: A three-dimensional analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steenbakkers, Roel; Duppen, Joop C.; Fitton, Isabelle

    2006-02-01

    Purpose: Target delineation using only CT information introduces large geometric uncertainties in radiotherapy for lung cancer. Therefore, a reduction of the delineation variability is needed. The impact of including a matched CT scan with 2-[{sup 18}F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) and adaptation of the delineation protocol and software on target delineation in lung cancer was evaluated in an extensive multi-institutional setting and compared with the delineations using CT only. Methods and Materials: The study was separated into two phases. For the first phase, 11 radiation oncologists (observers) delineated the gross tumor volume (GTV), including the pathologic lymph nodes of 22more » lung cancer patients (Stages I-IIIB) on CT only. For the second phase (1 year later), the same radiation oncologists delineated the GTV of the same 22 patients on a matched CT-FDG-PET scan using an adapted delineation protocol and software (according to the results of the first phase). All delineated volumes were analyzed in detail. The observer variation was computed in three dimensions by measuring the distance between the median GTV surface and each individual GTV. The variation in distance of all radiation oncologists was expressed as a standard deviation. The observer variation was evaluated for anatomic regions (lung, mediastinum, chest wall, atelectasis, and lymph nodes) and interpretation regions (agreement and disagreement; i.e., >80% vs. <80% of the radiation oncologists delineated the same structure, respectively). All radiation oncologist-computer interactions were recorded and analyzed with a tool called 'Big Brother.' Results: The overall three-dimensional observer variation was reduced from 1.0 cm (SD) for the first phase (CT only) to 0.4 cm (SD) for the second phase (matched CT-FDG-PET). The largest reduction in the observer variation was seen in the atelectasis region (SD 1.9 cm reduced to 0.5 cm). The mean ratio between the

  4. Evaluation of diagnostic value of CT scan, physical examination and ultrasound based on pathological findings in patients with pelvic masses.

    PubMed

    Firoozabadi, Razieh Dehghani; Karimi Zarchi, Mojgan; Mansurian, Hamid Reza; Moghadam, Bita Rafiei; Teimoori, Soraya; Naseri, Ali

    2011-01-01

    Because benign and malignant cervical and ovarian masses occur with different percentages in different age groups, the importance of primary diagnosis and selection of a suitable surgical procedure is underlined. Diagnosis of pelvic masses is carried out using ultrasound, physical examination, CT scan and MRI. The objective of this study is to evaluate the diagnostic value of CT scan in pelvic masses in comparison with physical examination-ultrasound based on pathology of the lesion in patients undergoing laparotomic surgery. This analytic-descriptive study focused on age, sonographic findings, physical examinations, CT scan and pathological findings in 139 patients with pelvic mass, gathered with questionnaires and statistically analayzed using the SPSS software programme. Of 139 patients with pelvic mass (patients aged from 17 to 75 years old), 62 (44%) cases were diagnosed as benign and 77 (55.4%) as malignant; among them malignant tratoma serocyst adenocarsinoma with 33 (23.7%) cases and benign myoma with 21 (15.2%) cases comprised the most frequent cases. The sensitivity and specificity of sonography-physical examination were 51.9% and 87.9% respectively and the sensitivity and specificity of CT scan images were 79.2% and 91.6% respectively. It was shown that CT scan images were more consistant with pathological findings in predicting appropriate surgical procedures than do sonography-physical examinations. The sensitivity of CT scan is far higher than that of sonography-physical examination in the diagnosis of pelvic mass malignancy.

  5. A comparison between intrastomal 3D ultrasonography, CT scanning and findings at surgery in patients with stomal complaints.

    PubMed

    Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K

    2014-10-01

    Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.

  6. CT biliary cystoscopy of gallbladder polyps

    PubMed Central

    Lou, Ming-Wu; Hu, Wei-Dong; Fan, Yi; Chen, Jin-Hua; E, Zhan-Sen; Yang, Guang-Fu

    2004-01-01

    AIM: CT virtual endoscopy has been used in the study of various organs of body including the biliary tract, however, CT virtual endoseopy in diagnosis of gallbladder polyps has not yet been reported. This study was to evaluate the diagnostic value of CT virtual endoscopy in polyps of the gallbladder. METHODS: Thirty-two cases of gallbladder polyps were examined by CT virtual endoscopy, ultrasound, CT scan with oral biliary contrast separately and confirmed by operation and pathology. CT biliary cystoscopic findings were analyzed and compared with those of ultrasound and CT scan with oral biliary contrast, and evaluated in comparison with operative and pathologic findings in all cases. RESULTS: The detection rate of gallbladder polyps was 93.8%(90/96), 96.9%(93/96) and 79.2%(76/96) for CT cystoscopy, ultrasound and CT scan with oral contrast, respectively. CT biliary cystoscopy corresponded well with ultrasound as well as pathology in demonstrating the location, size and configuration of polyps. CT endoscopy was superior to ultrasound in viewing the polyps in a more precise way, 3 dimensionally from any angle in space, and showing the surface in details. CT biliary cystoscopy was also superior to CT scan with oral biliary contrast in terms of observation of the base of polyps for the presence of a pedicle, detection rates as well as image quality. The smallest polyp detected by CT biliary cystoscopy was measured 1.5 mm×2.2 mm×2.5 mm. CONCLUSION: CT biliary cystoscopy is a non-invasive and accurate technique for diagnosis and management of gallbladder polyps. PMID:15069726

  7. Correlation between a 2D Channelized Hotelling Observer and Human Observers in a Low-contrast Detection Task with Multi-slice Reading in CT

    PubMed Central

    Yu, Lifeng; Chen, Baiyu; Kofler, James M.; Favazza, Christopher P.; Leng, Shuai; Kupinski, Matthew A.; McCollough, Cynthia H.

    2017-01-01

    .972, 95% confidence interval (CI): 0.919 to 0.990) and with the CHO_MS performance in the multi-slice viewing mode (R=0.952, 95% CI: 0.865 to 0.984). The CHO_2D performance, calculated from the 2D viewing mode, also had a strong correlation with human observer performance in the multi-slice viewing mode (R=0.957, 95% CI: 879 to 0.985). Human observer performance varied between the multi-slice and 2D modes. One reader performed better in the multi-slice mode (p=0.013); whereas the other two readers showed no significant difference between the two viewing modes (p=0.057 and p=0.38). Conclusions A 2D CHO model is highly correlated with human observer performance in detecting spherical low contrast objects in multi-slice viewing of CT images. This finding provides some evidence for the use of a simpler, 2D CHO to assess image quality in clinically relevant CT tasks where multi-slice viewing is used. PMID:28555878

  8. Small bowel obstruction due to phytobezoar formation within meckel diverticulum: CT findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frazzini, V.I. Jr.; English, W.J.; Bashist, B.

    1996-05-01

    Intestinal obstruction due to a phytobezoar within a Meckel diverticulum is exceedingly rare, with only seven reported cases in the surgical literature. The most important precipitating factor is the ingestion of agents high in fiber and cellulose. Small bowel obstruction in all but one case was due to retrograde propagation of the bezoar into the small bowel lumen. We report the clinical and CT findings in such a patient following a vegetarian diet. 14 refs., 2 figs.

  9. Correlation between model observers in uniform background and human observers in patient liver background for a low-contrast detection task in CT

    NASA Astrophysics Data System (ADS)

    Gong, Hao; Yu, Lifeng; Leng, Shuai; Dilger, Samantha; Zhou, Wei; Ren, Liqiang; McCollough, Cynthia H.

    2018-03-01

    Channelized Hotelling observer (CHO) has demonstrated strong correlation with human observer (HO) in both single-slice viewing mode and multi-slice viewing mode in low-contrast detection tasks with uniform background. However, it remains unknown if the simplest single-slice CHO in uniform background can be used to predict human observer performance in more realistic tasks that involve patient anatomical background and multi-slice viewing mode. In this study, we aim to investigate the correlation between CHO in a uniform water background and human observer performance at a multi-slice viewing mode on patient liver background for a low-contrast lesion detection task. The human observer study was performed on CT images from 7 abdominal CT exams. A noise insertion tool was employed to synthesize CT scans at two additional dose levels. A validated lesion insertion tool was used to numerically insert metastatic liver lesions of various sizes and contrasts into both phantom and patient images. We selected 12 conditions out of 72 possible experimental conditions to evaluate the correlation at various radiation doses, lesion sizes, lesion contrasts and reconstruction algorithms. CHO with both single and multi-slice viewing modes were strongly correlated with HO. The corresponding Pearson's correlation coefficient was 0.982 (with 95% confidence interval (CI) [0.936, 0.995]) and 0.989 (with 95% CI of [0.960, 0.997]) in multi-slice and single-slice viewing modes, respectively. Therefore, this study demonstrated the potential to use the simplest single-slice CHO to assess image quality for more realistic clinically relevant CT detection tasks.

  10. Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eck, Brendan L.; Fahmi, Rachid; Miao, Jun

    2015-10-15

    Purpose: Aims in this study are to (1) develop a computational model observer which reliably tracks the detectability of human observers in low dose computed tomography (CT) images reconstructed with knowledge-based iterative reconstruction (IMR™, Philips Healthcare) and filtered back projection (FBP) across a range of independent variables, (2) use the model to evaluate detectability trends across reconstructions and make predictions of human observer detectability, and (3) perform human observer studies based on model predictions to demonstrate applications of the model in CT imaging. Methods: Detectability (d′) was evaluated in phantom studies across a range of conditions. Images were generated usingmore » a numerical CT simulator. Trained observers performed 4-alternative forced choice (4-AFC) experiments across dose (1.3, 2.7, 4.0 mGy), pin size (4, 6, 8 mm), contrast (0.3%, 0.5%, 1.0%), and reconstruction (FBP, IMR), at fixed display window. A five-channel Laguerre–Gauss channelized Hotelling observer (CHO) was developed with internal noise added to the decision variable and/or to channel outputs, creating six different internal noise models. Semianalytic internal noise computation was tested against Monte Carlo and used to accelerate internal noise parameter optimization. Model parameters were estimated from all experiments at once using maximum likelihood on the probability correct, P{sub C}. Akaike information criterion (AIC) was used to compare models of different orders. The best model was selected according to AIC and used to predict detectability in blended FBP-IMR images, analyze trends in IMR detectability improvements, and predict dose savings with IMR. Predicted dose savings were compared against 4-AFC study results using physical CT phantom images. Results: Detection in IMR was greater than FBP in all tested conditions. The CHO with internal noise proportional to channel output standard deviations, Model-k4, showed the best trade

  11. Characteristic CT and MR imaging findings of cerebral paragonimiasis.

    PubMed

    Xia, Yong; Chen, Jing; Ju, Yan; You, Chao

    2016-06-01

    The early diagnosis of cerebral paragonimiasis (CP) is essential for a good prognosis. We seek to provide references for early diagnosis by analyzing the imaging characteristics of cerebral paragonimiasis. Images of 27 patients with CP (22 males and 5 females; median age 20.3 years; range: 4 to 47 years) were retrospectively evaluated. All patients underwent head computed tomography (CT) scans; 22 patients underwent conventional magnetic resonance imaging (MRI) sequences, including contrast-enhanced MRI for 20 patients and diffusion-weighted-imaging (DWI) for 1 patient. The diagnosis was confirmed based on a positive antibody test using enzyme-linked immunosorbent assay (ELISA) for paragonimiasis in the serum. The most common imaging findings of CP were isodense or hypodense lesions combined with extensive hypodense areas of perilesional edema on CT scans and a large mass composed of multiple ring-shaped lesions with surrounding edema on MRI images. The conglomeration of multiple ring-shaped lesions (n=11 patients), "tunnel signs" (n=12 patients) and worm-eaten signs (n=5 patients) were characteristic of most CP images. In 14 patients, contrast-enhanced MRI showed varying degrees of contrast enhancement combined with adjacent meningeal enhancement (n=10). A large mass comprising multiple ring-shaped lesions of different sizes, "tunnel signs" and worm-eaten signs with surrounding edema are the most characteristic features of CP. Extensive invasions of the adjacent meninges and ventricular wall (19 patients), multiple intracerebral lesions, bilateral hemispheric involvement, and lesion migration are other noteworthy imaging characteristics. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Life-threatening gastrointestinal system bleeding in Hodgkin disease: multidetector CT findings and review of the literature.

    PubMed

    Akpinar, Erhan; Türkbey, Bariş; Cil, Barbaros Erhan; Canyiğit, Murat; Dündar, Ziya; Balkanci, Ferhun

    2007-06-01

    Acute lower gastrointestinal system (GIS) bleeding is a life-threatening condition. Immediate determination of the origin of the bleeding is crucial, since hemostatic management must be initiated as rapidly as possible. Colonoscopy, radionuclide studies, and conventional angiography are considered the most important methods for assessing the origin of the bleeding. There are few published reports about the feasibility of computed tomography (CT) in acute GIS bleeding. We present multidetector CT (MDCT) findings in a case of Hodgkin disease status one month post-chemotherapy (CHOP protocol; cyclophosphamide, doxorubicin, vincristine, prednisone) that presented with acute lower GIS bleeding.

  13. [Preoperative CT Scan in middle ear cholesteatoma].

    PubMed

    Sethom, Anissa; Akkari, Khemaies; Dridi, Inès; Tmimi, S; Mardassi, Ali; Benzarti, Sonia; Miled, Imed; Chebbi, Mohamed Kamel

    2011-03-01

    To compare preoperative CT scan finding and per-operative lesions in patients operated for middle ear cholesteatoma, A retrospective study including 60 patients with cholesteatoma otitis diagnosed and treated within a period of 5 years, from 2001 to 2005, at ENT department of Military Hospital of Tunis. All patients had computed tomography of the middle and inner ear. High resolution CT scan imaging was performed using millimetric incidences (3 to 5 millimetres). All patients had surgical removal of their cholesteatoma using down wall technic. We evaluated sensitivity, specificity and predictive value of CT-scan comparing otitic damages and CT finding, in order to examine the real contribution of computed tomography in cholesteatoma otitis. CT scan analysis of middle ear bone structures shows satisfaction (with 83% of sensibility). The rate of sensibility decrease (63%) for the tympanic raff. Predictive value of CT scan for the diagnosis of cholesteatoma was low. However, we have noticed an excellent sensibility in the analysis of ossicular damages (90%). Comparative frontal incidence seems to be less sensible for the detection of facial nerve lesions (42%). But when evident on CT scan findings, lesions of facial nerve were usually observed preoperatively (spécificity 78%). Predictive value of computed tomography for the diagnosis of perilymphatic fistulae (FL) was low. In fact, CT scan imaging have showed FL only for four patients among eight. Best results can be obtained if using inframillimetric incidences with performed high resolution computed tomography. Preoperative computed tomography is necessary for the diagnosis and the evaluation of chronic middle ear cholesteatoma in order to show extending lesion and to detect complications. This CT analysis and surgical correlation have showed that sensibility, specificity and predictive value of CT-scan depend on the anatomic structure implicated in cholesteatoma damages.

  14. Comparison of CT and MRI findings for cervical spine clearance in obtunded patients without high impact trauma.

    PubMed

    Tan, Lee A; Kasliwal, Manish K; Traynelis, Vincent C

    2014-05-01

    Cervical spinal injuries occur in 2.0-6.6% of patients after blunt trauma and can have devastating neurological sequelae if left unrecognized. Although there is high quality evidence addressing cervical clearance in asymptomatic and symptomatic awake patients, cervical spine clearance in patients with altered level of alertness (i.e., obtunded patients with Glasgow coma scale (GCS) of 14 or less) following blunt trauma has been a matter of great controversy. Furthermore, there are no data on cervical spine clearance in obtunded patients without high impact trauma and these patients are often treated based on evidence from similar patients with high impact trauma. This retrospective study was conducted on this specific subgroup of patients who were admitted to a neurointensive care unit (NICU) with primary diagnoses of intracranial hemorrhage with history of minor trauma; the objective being to evaluate and compare cervical spinal computed tomography (CT) and magnetic resonance imaging (MRI) findings in this particular group of patients. Patients with GCS of 14 or less admitted to neruointensive care unit (NICU) at RUSH University Medical Center from 2008 to 2010 with diagnoses of intracranial hemorrhage (surgical or non-surgical) who had reported or presumed fall (i.e., "found down") were queried from the computer data registry. A group of these patients had cervical spine CT and subsequently MRI for clearing the cervical spine and removal of the cervical collar. Medical records of these patients were reviewed for demographics, GCS score and injury specific data and presence or absence of cervical spine injury. Eighty-three patients were identified from the computer database. Twenty-eight of these patients had positive findings on both CT and MRI (33.73% - Group I); four patients had a negative CT but had positive findings on follow-up MRI (4.82% - Group II); fifty-one patients had both negative CT and MRI (61.44% - Group III). All patients in Group I required

  15. Bronchiectasis: correlation of high-resolution CT findings with health-related quality of life.

    PubMed

    Eshed, I; Minski, I; Katz, R; Jones, P W; Priel, I E

    2007-02-01

    To evaluate the relationship between the severity of bronchiectatic diseases, as evident on high-resolution computed tomography (HRCT) and the patient's quality of life measured using the St George's Respiratory Questionnaire (SGRQ). Forty-six patients (25 women, 21 men, mean age: 63 years) with bronchiectatic disease as evident on recent HRCT examinations were recruited. Each patient completed the SGRQ and underwent respiratory function tests. HRCT findings were blindly and independently scored by two radiologists, using the modified Bhalla scoring system. The relationships between HRCT scores, SGRQ scores and pulmonary function tests were evaluated. The patients' total CT score did not correlate with the SGRQ scores. However, patients with more advanced disease on HRCT, significantly differed in their SGRQ scores from patients with milder bronchiectatic disease. A significant correlation was found between the CT scores for the middle and distal lung zones and the activity, impacts and total SGRQ scores. No correlation was found between CT scores and respiratory function test indices. However, a significant correlation was found between the SGRQ scores and most of the respiratory function test indices. A correlation between the severity of bronchiectatic disease as expressed in HRCT and the health-related quality of life exists in patients with a more severe bronchiectatic disease but not in patients with mild disease. Such correlation depends on the location of the bronchiectasis in the pulmonary tree.

  16. Automatically pairing measured findings across narrative abdomen CT reports.

    PubMed

    Sevenster, Merlijn; Bozeman, Jeffrey; Cowhy, Andrea; Trost, William

    2013-01-01

    Radiological measurements are one of the key variables in widely adopted guidelines (WHO, RECIST) that standardize and objectivize response assessment in oncology care. Measurements are typically described in free-text, narrative radiology reports. We present a natural language processing pipeline that extracts measurements from radiology reports and pairs them with extracted measurements from prior reports of the same clinical finding, e.g., lymph node or mass. A ground truth was created by manually pairing measurements in the abdomen CT reports of 50 patients. A Random Forest classifier trained on 15 features achieved superior results in an end-to-end evaluation of the pipeline on the extraction and pairing task: precision 0.910, recall 0.878, F-measure 0.894, AUC 0.988. Representing the narrative content in terms of UMLS concepts did not improve results. Applications of the proposed technology include data mining, advanced search and workflow support for healthcare professionals managing radiological measurements.

  17. Criteria for CT and Initial Management of Head Injured Infants: A Review

    PubMed Central

    SHIOMI, Naoto; ECHIGO, Tadashi; HINO, Akihiko; HASHIMOTO, Naoya; YAMAKI, Tarumi

    2016-01-01

    Criteria for computed tomography (CT) to head injured infants have not been established. Since the identification of neurological findings is difficult in infants, examination by CT may be necessary in some cases, but it may be difficult to perform CT because of problems with radiation exposure and body movement. Moreover, even though no intracranial abnormality was found immediately after injury, abnormal findings may appear after several hours. From this viewpoint, course observation after injury may be more important than CT in the initial treatment of head trauma in infants. The complaints and neurological manifestations of infants, particularly those aged 2 or younger, are frequently unclear; therefore, there is an opinion that CT is recommended for all pediatric patients. However, the appropriateness of its use should be determined after confirming the mechanism of injury, consciousness level, neurological findings, and presence/absence of a history of abuse. Among the currently available rules specifying criteria for CT of infants with head trauma, the Pediatric Emergency Care Applied Research Network (PECARN) study may be regarded as reliable at present. In Japan, where the majority of emergency hospitals are using CT, it may be necessary to develop criteria for CT in consideration of the actual situation. CT diagnosis for pediatric head trauma is not always necessary. When no imaging is performed, this should be fully explained at the initial treatment before selecting course observation at home. Checking on a state of the patients by telephone is useful for both patients and physicians. PMID:27194179

  18. CT and MR imaging findings of lymphangioleiomyomatosis involving the uterus and pelvic cavity.

    PubMed

    Kim, You Sung; Rha, Sung Eun; Byun, Jae Young; Lee, Ahwon; Park, Jong Sup

    2011-01-01

    Lymphangioleiomyomatosis (LAM) is a rare idiopathic disease and this is characterized by a proliferation of abnormal smooth muscle cells in the lungs and in the lymphatic system of the thorax and retroperitoneum. The female genital tract is rarely affected by LAM. We report here on the CT and MR imaging findings of extensive LAM involving the uterus and pelvic cavity, and this was seen as multiple cystic uterine and parauterine masses with internal hemorrhage in a young female with tuberous sclerosis complex.

  19. Follow-up CT findings of tamoxifen-induced non-alcoholic steatohepatitis (NASH) of breast cancer patients treated with bezafibrate.

    PubMed

    Ogawa, Yasuhiro; Murata, Yoriko; Saibara, Toshiji; Nishioka, Akihito; Kariya, Shinji; Yoshida, Shoji

    2003-01-01

    One-third of the breast cancer patients who underwent tamoxifen intake showed less than 0.9 of their liver/spleen CT (computed tomography) ratio on their annual CT study, and were diagnosed as having fatty liver (hepatic steatosis). Among them, patients who showed a lower liver/spleen CT ratio of less than 0.5 were recommended to undergo needle biopsy of the liver in order to obtain histopathological confirmation of non-alcoholic steatohepatitis (NASH), with 15 patients undergoing needle biopsy of the liver. As a result, 14 out of the 15 patients were diagnosed as having NASH, and these patients were additionally administered bezafibrate in order to prevent possible progressive changes of NASH into liver cirrhosis. In this study, we show the changes of follow-up CT findings of 6 patients with histopathologically-proven NASH who continued to undergo bezafibrate intake after the diagnosis of NASH. Two patients showed almost complete improvement as indicated by the liver/spleen CT ratio several months after completion of a tamoxifen intake of 5 years, and another 3 showed partial improvement on their liver/spleen CT ratio by bezafibrate intake in spite of continuing tamoxifen intake. Another patient with diabetes mellitus (type II) showed a continually decreasing liver/spleen CT ratio during adjuvant tamoxifen in spite of bezafibrate intake. Therefore, we concluded that the progression of NASH could be prevented by bezafibrate without any interruption of adjuvant tamoxifen treatment. For patients with diabetes mellitus, critical follow-up using CT study and laboratory tests is considered essential.

  20. Frequency and distribution of incidental findings deemed appropriate for S modifier designation on low-dose CT in a lung cancer screening program.

    PubMed

    Reiter, Michael J; Nemesure, Allison; Madu, Ezemonye; Reagan, Lisa; Plank, April

    2018-06-01

    To describe the frequency, distribution and reporting patterns of incidental findings receiving the Lung-RADS S modifier on low-dose chest computed tomography (CT) among lung cancer screening participants. This retrospective investigation included 581 individuals who received baseline low-dose chest CT for lung cancer screening between October 2013 and June 2017 at a single center. Incidental findings resulting in assignment of Lung-RADS S modifier were recorded as were incidental abnormalities detailed within the body of the radiology report only. A subset of 60 randomly selected CTs was reviewed by a second (blinded) radiologist to evaluate inter-rater variability of Lung-RADS reporting. A total of 261 (45%) participants received the Lung-RADS S modifier on baseline CT with 369 incidental findings indicated as potentially clinically significant. Coronary artery calcification was most commonly reported, accounting for 182 of the 369 (49%) findings. An additional 141 incidentalomas of the same types as these 369 findings were described in reports but were not labelled with the S modifier. Therefore, as high as 69% (402 of 581) of participants could have received the S modifier if reporting was uniform. Inter-radiologist concordance of S modifier reporting in a subset of 60 participants was poor (42% agreement, kappa = 0.2). Incidental findings are commonly identified on chest CT for lung cancer screening, yet reporting of the S modifier within Lung-RADS is inconsistent. Specific guidelines are necessary to better define potentially clinically significant abnormalities and to improve reporting uniformity. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. An anencephalic monocephalus diprosopus "headed twin": postmortem and CT findings with emphasis on the cranial bones.

    PubMed

    Ekinci, Gazanfer; Balci, Sevim; Erzen, Canan

    2005-01-01

    Monocephalus diprosopus is a form of conjoined twinning characterized by a single body, one unusual head and two faces or a spectrum of duplication of the craniofacial structures. Such cases have been mainly described according to postmortem pathologic examination. This presented case is a 26-week-stillborn female fetus, with unusual facial appearance with four eyes, two mouths, two noses, two ears and a defective cranial vault. To our knowledge, a detailed computerized tomography (CT) examination of the aberrant facial and cranial bones of such a case has not been reported to date. In this reported case, we present an anencephalic monocephalus diprosopus "headed twin", and describe the CT findings with emphasis on the cranial bones.

  2. CT and MR findings in synovial chondromatosis of the temporo-mandibular joint: our experience and review of literature.

    PubMed

    Testaverde, Lorenzo; Perrone, Anna; Caporali, Laura; Ermini, Antonella; Izzo, Luciano; D'Angeli, Ilaria; Impara, Luca; Mazza, Dario; Izzo, Paolo; Marini, Mario

    2011-06-01

    To compare Computed Tomography (CT) and Magnetic Resonance (MR) features and their diagnostic potential in the assessment of Synovial Chondromatosis (SC) of the Temporo-Mandibular Joint (TMJ). Eight patients with symptoms and signs compatible with dysfunctional disorders of the TMJ underwent CT and MR scan. We considered the following parameters: soft tissue involvement (disk included), osteostructural alterations of the joints, loose bodies and intra-articular fluid. These parameters were evaluated separately by two radiologists with a "double blinded method" and then, after agreement, definitive assessment of the parameters was given. CT and MR findings were compared. Histopathological results showed metaplastic synovia in all patients and therefore confirmed diagnosis of SC. MR resulted better than CT in the evaluation of all parameters except the osteostructural alterations of the joints, estimated with more accuracy by CT scan. CT scan is excellent to define bony surfaces of the articular joints and flogistic tissue but it fails in the detection of loose bodies when these are not yet calcified. MR scan therefore is the gold standard when SC is suspected since it can visualize loose bodies at early stage and also evaluate disk condition and eventual extra-articular tissues involvement. The use of T2-weighted images and contrast medium allows identifying intra-articular fluid, estimating its entity and discriminating from sinovial tissue. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  3. (18)F-FDG PET/CT findings in a case with HIV (-) Kaposi sarcoma.

    PubMed

    Ozdemir, E; Poyraz, N Y; Keskin, M; Kandemir, Z; Turkolmez, S

    2014-01-01

    Although mucocutaneous sites are the most frequently encountered sites of involvement, Kaposi Sarcoma (KS) may also occasionally involve the breast and the skeletal, endocrine, urinary and nervous systems.. Various imaging modalities may be used to delineate the extent of the disease by detecting unexpected sites of involvement. Herein, we report a case of classical type KS, in whom staging with (18)F-FDG PET/CT imaging disclosed widespread disease and unexpected findings of bone and salivary gland involvement. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  4. Diagnostic value of CT, PET and combined PET/CT performed with low-dose unenhanced CT and full-dose enhanced CT in the initial staging of lymphoma.

    PubMed

    Pinilla, I; Gómez-León, N; Del Campo-Del Val, L; Hernandez-Maraver, D; Rodríguez-Vigil, B; Jover-Díaz, R; Coya, J

    2011-10-01

    The aim of this paper was to compare the accuracy of contrast-enhanced computed tomography (CT), positron emission tomography (PET), unenhanced low-dose PET/CT (LD-PET/CT) and full-dose enhanced PET/CT (FD-PET/CT) for the initial staging of lymphoma. One hundred and one lymphoma patients were examined by [18F]FDG-PET/CT including unenhanced low-dose CT and enhanced full-dose CT. Each modality of PET/CT was evaluated by a nuclear medicine physician and a radiologist unaware of the other modality, while the CT and PET images were interpreted separately by another independent radiologist and nuclear medicine physician respectively. The nodal and extranodal lesions detected by each technique were compared with a reference standard. For nodal assessment, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), and negative LR (LR-) of LD-PET/CT were 97%, 96%, 98%, 95%, 26 and 0.02 respectively, and those of FD-PET/CT were 97%, 97%, 98%, 95%, 36 and 0.02. These results were significantly better than those of PET (sensitivity 82%, specificity 81%, PPV 88%, NPV 72%, LR+ 4.3, LR- 0.21). Likewise, both PET/CT displayed a higher sensitivity, NPV and LR- than CT (91%, 84%, 0.1 respectively). For organ evaluation, both modalities of PET/CT also had significantly better sensitivity and NPV than that of PET (LD-PET/CT: sensitivity 92%, NPV 90%; FD-PET/CT sensitivity 94%, NPV 92%; PET: sensitivity 70%, NPV 69%). The sensitivity, specificity, PPV and NPV for bone marrow involvement were 29%, 84%, 45% and 72% respectively for PET, and 29%, 90%, 56%, and 74% for both, LD-PET/CT, and FD-PET/CT. No significant differences were found between LD-PET/CT and FD-PET/CT, but FD-PET/CT detected important incidental findings in 5.9% of patients. PET/CT is an accurate technique for the initial staging of lymphomas without significant differences between LD-PET/CT and FD-PET/CT. FD-PET/CT detects relevant incidental findings

  5. CT findings in malignant pleural mesothelioma related to nonoccupational exposure to asbestos and fibrous zeolite (erionite)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erzen, C.; Eryilmaz, M.; Kalyoncu, F.

    1991-03-01

    Endemic malignant pleural mesothelioma (MPM) in Turkey is related to two mineral fibers, tremolite asbestos and fibrous zeolite (erionite). Thirteen cases of MPM from the Cappadocian area, where the soil is rich in erionite, and 29 cases of MPM, from villages whose occupants have high asbestos exposure, were examined by CT. The CT findings of the two groups of MPM were compared with respect to the configuration of the pleural lesions, stage of disease, fissural involvement, pleural effusion, presence of calcified pleural plaques, and chronic fibrosing pleuritis. In erionite-related MPM the pleural lesions were flat and smooth in 69.1%; inmore » asbestos-related MPM the lesions were nodular in 55.1%. Stage IV disease, calcified pleural plaques, and chronic fibrosing pleuritis were more common in the erionite-related MPM. The rest of the findings were similar in both groups. The early radiological diagnosis of erionite-related MPM may be even more difficult because of the similarity of the pleural lesions to chronic fibrosing pleuritis.« less

  6. Pulmonary effects of synthetic marijuana: chest radiography and CT findings.

    PubMed

    Berkowitz, Eugene A; Henry, Travis S; Veeraraghavan, Srihari; Staton, Gerald W; Gal, Anthony A

    2015-04-01

    The purpose of this article is to present the first chest radiographic and CT descriptions of organizing pneumonia in response to smoking synthetic marijuana. Chest radiographs showed a diffuse miliary-micronodular pattern. Chest CT images showed diffuse centrilobular nodules and tree-in-bud pattern and a histopathologic pattern of organizing pneumonia with or without patchy acute alveolar damage. This distinct imaging pattern should alert radiologists to include synthetic marijuana abuse in the differential diagnosis.

  7. F-18 FDG PET/CT findings in a patient with bilateral orbital and gastric mucosa-associated lymphoid tissue lymphomas.

    PubMed

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Hiyama, Atsuto; Takeda, Koumei; Matsunaga, Naofumi

    2009-09-01

    Orbital mucosa-associated lymphoid tissue (MALT) lymphoma is an uncommon disease, while the incidence is recently increasing. We describe the F-18 fluorodeoxyglucose positron emission tomography computerized tomography (FDG PET/CT) findings in a case of bilateral orbital MALT lymphomas with a coexisting gastric lesion. Although only the lesion in the left orbit was initially identified on MR imaging, FDG PET/CT scan unexpectedly and additionally could identify the tiny lesion of the contralateral orbit and the gastric lesion. This patient received radiotherapy to all these lesions, with a combination of rituximab monoclonal antibody therapy. The follow-up PET/CT studies at 3, 6, and 9 months and 1.5 years after treatment showed regression or disappearance of all these FDG-avid lesions. Accurate localization and staging are crucial to select an adequate treatment in MALT lymphoma at any location. This case indicates the feasibility of FDG PET/CT scan for accurate localization and staging and also for monitoring treatment in patients with orbital MALT lymphoma.

  8. Melorheostosis involving the cervical and upper thoracic spine: radiographic, CT, and MR imaging findings.

    PubMed

    Motimaya, A M; Meyers, S P

    2006-01-01

    Melorheostosis, an uncommon mesenchymal dysplasia, rarely affects the axial skeleton. We describe the imaging findings of melorheostosis involving the cervical and upper thoracic spine. Radiographs and CT showed unilateral well-marginated undulating zones of cortical hyperostosis involving multiple vertebrae that were contiguous with a coalescent ossified right paravertebral mass. MR imaging showed zones of signal intensity void on all pulse sequences without contrast enhancement. Conservative management was elected because of lack of interval clinical and imaging changes for 8 years.

  9. Clinical features and neuroimaging (CT and MRI) findings in presumed Zika virus related congenital infection and microcephaly: retrospective case series study.

    PubMed

    de Fatima Vasco Aragao, Maria; van der Linden, Vanessa; Brainer-Lima, Alessandra Mertens; Coeli, Regina Ramos; Rocha, Maria Angela; Sobral da Silva, Paula; Durce Costa Gomes de Carvalho, Maria; van der Linden, Ana; Cesario de Holanda, Arthur; Valenca, Marcelo Moraes

    2016-04-13

    To report radiological findings observed in computed tomography (CT) and magnetic resonance imaging (MRI) scans of the first cases of congenital infection and microcephaly presumably associated with the Zika virus in the current Brazilian epidemic. Retrospective study with a case series. Association for Assistance of Disabled Children (AACD), Pernambuco state, Brazil. 23 children with a diagnosis of congenital infection presumably associated with the Zika virus during the Brazilian microcephaly epidemic. Types of abnormalities and the radiological pattern of lesions identified on CT and MRI brain scans. Six of the 23 children tested positive for IgM antibodies to Zika virus in cerebrospinal fluid. The other 17 children met the protocol criteria for congenital infection presumably associated with the Zika virus, even without being tested for IgM antibodies to the virus--the test was not yet available on a routine basis. Of the 23 children, 15 underwent CT, seven underwent both CT and MRI, and one underwent MRI. Of the 22 children who underwent CT, all had calcifications in the junction between cortical and subcortical white matter, 21 (95%) had malformations of cortical development, 20 (91%) had a decreased brain volume, 19 (86%) had ventriculomegaly, and 11 (50%) had hypoplasia of the cerebellum or brainstem. Of the eight children who underwent MRI, all had calcifications in the junction between cortical and subcortical white matter, malformations of cortical development occurring predominantly in the frontal lobes, and ventriculomegaly. Seven of the eight (88%) children had enlarged cisterna magna, seven (88%) delayed myelination, and six each (75%) a moderate to severe decrease in brain volume, simplified gyral pattern, and abnormalities of the corpus callosum (38% hypogenesis and 38% hypoplasia). Malformations were symmetrical in 75% of the cases. Severe cerebral damage was found on imaging in most of the children in this case series with congenital infection

  10. Clinical features and neuroimaging (CT and MRI) findings in presumed Zika virus related congenital infection and microcephaly: retrospective case series study

    PubMed Central

    van der Linden, Vanessa; Brainer-Lima, Alessandra Mertens; Coeli, Regina Ramos; Rocha, Maria Angela; Sobral da Silva, Paula; Durce Costa Gomes de Carvalho, Maria; van der Linden, Ana; Cesario de Holanda, Arthur; Valenca, Marcelo Moraes

    2016-01-01

    Objective To report radiological findings observed in computed tomography (CT) and magnetic resonance imaging (MRI) scans of the first cases of congenital infection and microcephaly presumably associated with the Zika virus in the current Brazilian epidemic. Design Retrospective study with a case series. Setting Association for Assistance of Disabled Children (AACD), Pernambuco state, Brazil. Participants 23 children with a diagnosis of congenital infection presumably associated with the Zika virus during the Brazilian microcephaly epidemic. Main outcome measures Types of abnormalities and the radiological pattern of lesions identified on CT and MRI brain scans. Results Six of the 23 children tested positive for IgM antibodies to Zika virus in cerebrospinal fluid. The other 17 children met the protocol criteria for congenital infection presumably associated with the Zika virus, even without being tested for IgM antibodies to the virus—the test was not yet available on a routine basis. Of the 23 children, 15 underwent CT, seven underwent both CT and MRI, and one underwent MRI. Of the 22 children who underwent CT, all had calcifications in the junction between cortical and subcortical white matter, 21 (95%) had malformations of cortical development, 20 (91%) had a decreased brain volume, 19 (86%) had ventriculomegaly, and 11 (50%) had hypoplasia of the cerebellum or brainstem. Of the eight children who underwent MRI, all had calcifications in the junction between cortical and subcortical white matter, malformations of cortical development occurring predominantly in the frontal lobes, and ventriculomegaly. Seven of the eight (88%) children had enlarged cisterna magna, seven (88%) delayed myelination, and six each (75%) a moderate to severe decrease in brain volume, simplified gyral pattern, and abnormalities of the corpus callosum (38% hypogenesis and 38% hypoplasia). Malformations were symmetrical in 75% of the cases. Conclusion Severe cerebral damage was

  11. Design of a practical model-observer-based image quality assessment method for CT imaging systems

    NASA Astrophysics Data System (ADS)

    Tseng, Hsin-Wu; Fan, Jiahua; Cao, Guangzhi; Kupinski, Matthew A.; Sainath, Paavana

    2014-03-01

    The channelized Hotelling observer (CHO) is a powerful method for quantitative image quality evaluations of CT systems and their image reconstruction algorithms. It has recently been used to validate the dose reduction capability of iterative image-reconstruction algorithms implemented on CT imaging systems. The use of the CHO for routine and frequent system evaluations is desirable both for quality assurance evaluations as well as further system optimizations. The use of channels substantially reduces the amount of data required to achieve accurate estimates of observer performance. However, the number of scans required is still large even with the use of channels. This work explores different data reduction schemes and designs a new approach that requires only a few CT scans of a phantom. For this work, the leave-one-out likelihood (LOOL) method developed by Hoffbeck and Landgrebe is studied as an efficient method of estimating the covariance matrices needed to compute CHO performance. Three different kinds of approaches are included in the study: a conventional CHO estimation technique with a large sample size, a conventional technique with fewer samples, and the new LOOL-based approach with fewer samples. The mean value and standard deviation of area under ROC curve (AUC) is estimated by shuffle method. Both simulation and real data results indicate that an 80% data reduction can be achieved without loss of accuracy. This data reduction makes the proposed approach a practical tool for routine CT system assessment.

  12. [Clinical and pathological significance of carotid siphon calcification observed on bone condition of brain CT].

    PubMed

    Matsumoto, Hideyuki; Hamaguchi, Hirotoshi; Nakayama, Takahiro; Oda, Tetsuya; Ikagawa, Takashi; Imafuku, Ichiro

    2008-02-01

    On plain brain computed tomography (CT), it is difficult to evaluate stenosis of internal carotid artery (ICA) because ICA is surrounded by structures, even though we can observe calcification of carotid siphon in some patients by using bone condition. However the pathologic significance has not been well known. We studied the pathologic significance of carotid siphon calcification observed on bone condition of brain CT. A total of 112 patients who were diagnosed or suspected as cerebrovascular diseases were registered. We classified the calcification into four levels (none, mild, moderate, severe) based on the degree of calcification. Then we compared it with the degree of stenosis of carotid siphon seen on brain magnetic resonance angiography (MRA) and with max intima-medial thickness (IMT) from common carotid artery (CCA) to ICA on carotid ultrasonography. The mean +/- standard deviation of max IMT to none, mild, moderate and severe in the degree of calcification were 1.03 +/- 0.64 (0.4-2.8), 1.65 +/- 0.83 (0.5-4.1), 2.03 +/- 0.83 (0.8-4.1) and 2.81 +/- 1.15 (0.7-6.5) mm, respectively. The calcification on brain CT significantly correlated with the degree of stenosis on brain MRA and with max IMT on carotid ultrasonography. The calcification of carotid siphon on bone condition of brain CT correlated with stenosis of the same portion and atherosclerosis of CCA bifurcation. Recently, on DICOM viewer, clinicians can convert plain condition into bone condition on brain CT due to popularization of PACS. We should pay attention to calcification of carotid siphon in patients with ischemic cerebrovascular diseases because we can estimate the atherosclerosis of both carotid siphon and CCA bifurcation easily and immediately.

  13. C2 spondylotic radiculopathy: the nerve root impingement mechanism investigated by para-sagittal CT/MRI, dynamic rotational CT, intraoperative microscopic findings, and treated by microscopic posterior foraminotomy.

    PubMed

    Fujiwara, Yasushi; Izumi, Bunichiro; Fujiwara, Masami; Nakanishi, Kazuyoshi; Tanaka, Nobuhiro; Adachi, Nobuo; Manabe, Hideki

    2017-04-01

    C2 radiculopathy is known to cause occipito-cervical pain, but their pathology is unclear because of its rarity and unique anatomy. In this paper, we investigated the mechanism of C2 radiculopathy that underwent microscopic cervical foraminotomies (MCF). Three cases with C2 radiculopathy treated by MCF were investigated retrospectively. The mean follow-up period was 24 months. Pre-operative symptoms, imaging studies including para-sagittal CT and MRI, rotational dynamic CT, and intraoperative findings were investigated. There were 1 male and 2 females. The age of patients were ranged from 50 to 79 years. All cases had intractable occipito-cervical pain elicited by the cervical rotation. C2 nerve root block was temporally effective. There was unilateral spondylosis in symptomatic side without obvious atlatoaxial instability. Para-sagittal MRI and CT showed severe foraminal stenosis at C1-C2 due to the bony spur derived from the lateral atlanto-axial joints. In one case, dynamic rotational CT showed that the symptomatic foramen became narrower on rotational position. MCF was performed in all cases, and the C2 nerve root was impinged between the inferior edge of the C1 posterior arch and bony spur from the C1-C2 joint. After surgery, occipito-cervical pain disappeared. This study demonstrated that mechanical impingement of the C2 nerve root is one of the causes of occipito-cervical pain and it was successfully treated by microscopic resection of the inferior edge of the C1 posterior arch. Para-sagittal CT and MRI, rotational dynamic CT, and nerve root block were effective for diagnosis.

  14. Ultra low dose CT screen-detected non-malignant incidental findings in the Western Australian Asbestos Review Programme.

    PubMed

    Murray, Conor P; Wong, Patrick M; Teh, Joelin; de Klerk, Nick; Rosenow, Tim; Alfonso, Helman; Reid, Alison; Franklin, Peter; Musk, A W Bill; Brims, Fraser J H

    2016-11-01

    Computed tomography (CT)-based studies of asbestos-exposed individuals report a high prevalence of lung cancer, but the utility of low dose CT (LDCT) to screen asbestos-exposed populations is not established. We aimed to describe the prevalence of indeterminate pulmonary nodules and incidental findings on chest LDCT of asbestos-exposed subjects in Western Australia. A total of 906 subjects from the Western Australian Asbestos Review Programme underwent LDCT of the chest as part of regular annual review. An indeterminate (solid) nodule was defined as >50 mm 3 and part-solid/non-solid nodules >5 mm. The presence of asbestos-related diseases was recorded with a standardized report. Subjects were mostly (81%) men with a median age of 70 years. Fifty-eight (6.5%) participants were current smokers, 511 (56.4%) ex-smokers and 325 (36.4%) never-smokers. One hundred and four indeterminate nodules were detected in 77 subjects (8.5%); of these, eight cases had confirmed lung cancer (0.88%). Eighty-seven subjects (9.6%) had incidental findings that required further investigation, 42 (4.6%) from lower airways inflammation. The majority of nodules were solid, 4-6 mm and more common with age. Five hundred and eighty (64%) subjects had pleural plaques, and 364 (40.2%) had evidence of interstitial lung disease. The prevalence of LDCT-detected indeterminate lung nodules in 906 individuals with significant asbestos exposure was 8.5%, lower than many other CT studies. Clinically important incidental findings were found in 9.4%, predominantly related to lower respiratory tract inflammation. LDCT appears to effectively describe asbestos-related diseases and is likely to be an acceptable modality to monitor asbestos-exposed individuals. © 2016 Asian Pacific Society of Respirology.

  15. SU-E-I-31: Differences Observed in Radiation Doses Across 2 Similar CT Scanners From Adult Brain-Neck CT Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujii, K; UCLA School of Medicine, Los Angeles, CA; McMillan, K

    2015-06-15

    Purpose: The aim of this study is to evaluate the difference in radiation doses from adult Brain-Neck CT angiography (CTA) between two CT scanners. Methods: We collected CT dose index data (CTDIvol, DLP) from adult Brain-Neck CTA performed with two CT scanners (Sensation 64 (S64) and Definition AS (AS), Siemens Healthcare) performed at two of our facilities from Jan 1st to Dec 31th, 2014. X-ray dose management software (Radmetrics, Bayer Healthcare) was used to mine these data. All exams were performed with Tube Current Modulation (Care Dose 4D), tube voltage of 120 kVp, quality reference mAs of 300, beam collimationmore » of 64*0.6 mm. The rotation time was set to 0.5 sec for S64 and 1.0 sec for AS. We also scanned an anthropomorphic skull and chest phantom under routine Brain-Neck CTA protocol with the two scanners and extracted the tube current values from the raw projection data. Results: The mean CTDIvol and DLP in Brain-Neck CTA was 72 mGy and 2554 mGy*cm for AS, which was substantially larger than the mean values of 46 mGy and 1699 mGy*cm for S64. The maximum tube current was 583 mA for most cases on the S64 while the maximum was 666 mA for AS even though the rotation time set for AS was 1.0 sec. Measurements obtained with the anthropomorphic phantom showed that the tube current reached 583 mA at the shoulder region for S64 while it reached to 666 mA for AS. Conclusion: The results of this study showed that substantially different CT doses can Result from Brain-Neck CTA protocols even when similar scanners and similar settings are used. Though both scanners have a similar maximum mA rating, differences in mA were observed through the shoulders, resulting in substantially different CTDIvol values.« less

  16. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    PubMed

    Mui, Leonora W; Engelsohn, Eliyahu; Umans, Hilary

    2007-02-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury.

  17. CT abdominal imaging findings in patients with sickle cell disease: acute vaso-occlusive crisis, complications, and chronic sequelae.

    PubMed

    Gardner, Carly S; Boll, Daniel T; Bhosale, Priya; Jaffe, Tracy A

    2016-12-01

    Sickle cell disease (SCD) is the most prevalent hemoglobinopathy. Survival in patients with SCD has improved over the past few decades. These patients experience a lifetime of repeated acute pain crises, which are thought to result from sickling and microvascular occlusions; acute abdominal pain is common. Moreover, repeated crises often lead to organ dysfunction, such as asplenia, hepatic failure, and renal failure. The spleen, liver, biliary system, kidneys, and gastrointestinal tract can all be affected. Patients may undergo CT to further direct clinical management. We review the spectrum of CT imaging findings of abdominal manifestations in patients with SCD, from the acute microvascular occlusive pain crisis to the potential complications and chronic sequelae.

  18. Derivation and validation of two decision instruments for selective chest CT in blunt trauma: a multicenter prospective observational study (NEXUS Chest CT).

    PubMed

    Rodriguez, Robert M; Langdorf, Mark I; Nishijima, Daniel; Baumann, Brigitte M; Hendey, Gregory W; Medak, Anthony J; Raja, Ali S; Allen, Isabel E; Mower, William R

    2015-10-01

    Unnecessary diagnostic imaging leads to higher costs, longer emergency department stays, and increased patient exposure to ionizing radiation. We sought to prospectively derive and validate two decision instruments (DIs) for selective chest computed tomography (CT) in adult blunt trauma patients. From September 2011 to May 2014, we prospectively enrolled blunt trauma patients over 14 y of age presenting to eight US, urban level 1 trauma centers in this observational study. During the derivation phase, physicians recorded the presence or absence of 14 clinical criteria before viewing chest imaging results. We determined injury outcomes by CT radiology readings and categorized injuries as major or minor according to an expert-panel-derived clinical classification scheme. We then employed recursive partitioning to derive two DIs: Chest CT-All maximized sensitivity for all injuries, and Chest CT-Major maximized sensitivity for only major thoracic injuries (while increasing specificity). In the validation phase, we employed similar methodology to prospectively test the performance of both DIs. We enrolled 11,477 patients-6,002 patients in the derivation phase and 5,475 patients in the validation phase. The derived Chest CT-All DI consisted of (1) abnormal chest X-ray, (2) rapid deceleration mechanism, (3) distracting injury, (4) chest wall tenderness, (5) sternal tenderness, (6) thoracic spine tenderness, and (7) scapular tenderness. The Chest CT-Major DI had the same criteria without rapid deceleration mechanism. In the validation phase, Chest CT-All had a sensitivity of 99.2% (95% CI 95.4%-100%), a specificity of 20.8% (95% CI 19.2%-22.4%), and a negative predictive value (NPV) of 99.8% (95% CI 98.9%-100%) for major injury, and a sensitivity of 95.4% (95% CI 93.6%-96.9%), a specificity of 25.5% (95% CI 23.5%-27.5%), and a NPV of 93.9% (95% CI 91.5%-95.8%) for either major or minor injury. Chest CT-Major had a sensitivity of 99.2% (95% CI 95.4%-100%), a specificity of

  19. Recurrent malignant pheochromocytoma with unusual omental metastasis: 68Ga-DOTANOC PET/CT and 131I-MIBG SPECT/CT scintigraphy findings

    PubMed Central

    Arora, Saurabh; Agarwal, Krishan Kant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Pheochromocytomas are rare catecholamine-secreting tumors derived from the sympathetic nervous system. The most common sites of metastasis for pheochromocytoma or extra-adrenal paraganglioma are lymph nodes, bones, lungs, and liver. Patients with known or suspected malignancy should undergo staging with computed tomography (CT) or magnetic resonance imaging as well as functional imaging (e.g. with 123I/131I-MIBG (131I-metaiodobenzylguanidine) and 68Ga-DOTANOC (68Ga-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-NaI3-octreotide) positron emission tomography (PET)/CT) to determine the extent and location of disease. We present a case of recurrent malignant pheochromocytoma with unusual site of metastasis in omentum, which was positive on 68Ga-DOTANOC PET/CT and 131I-MIBG single-photon emission computed tomography (SPECT/)/CT scintigraphy. PMID:25400380

  20. Recurrent malignant pheochromocytoma with unusual omental metastasis: (68)Ga-DOTANOC PET/CT and (131)I-MIBG SPECT/CT scintigraphy findings.

    PubMed

    Arora, Saurabh; Agarwal, Krishan Kant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-10-01

    Pheochromocytomas are rare catecholamine-secreting tumors derived from the sympathetic nervous system. The most common sites of metastasis for pheochromocytoma or extra-adrenal paraganglioma are lymph nodes, bones, lungs, and liver. Patients with known or suspected malignancy should undergo staging with computed tomography (CT) or magnetic resonance imaging as well as functional imaging (e.g. with (123)I/(131)I-MIBG ((131)I-metaiodobenzylguanidine) and (68)Ga-DOTANOC ((68)Ga-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-NaI3-octreotide) positron emission tomography (PET)/CT) to determine the extent and location of disease. We present a case of recurrent malignant pheochromocytoma with unusual site of metastasis in omentum, which was positive on (68)Ga-DOTANOC PET/CT and (131)I-MIBG single-photon emission computed tomography (SPECT/)/CT scintigraphy.

  1. Standard and reduced radiation dose liver CT images: adaptive statistical iterative reconstruction versus model-based iterative reconstruction-comparison of findings and image quality.

    PubMed

    Shuman, William P; Chan, Keith T; Busey, Janet M; Mitsumori, Lee M; Choi, Eunice; Koprowicz, Kent M; Kanal, Kalpana M

    2014-12-01

    To investigate whether reduced radiation dose liver computed tomography (CT) images reconstructed with model-based iterative reconstruction ( MBIR model-based iterative reconstruction ) might compromise depiction of clinically relevant findings or might have decreased image quality when compared with clinical standard radiation dose CT images reconstructed with adaptive statistical iterative reconstruction ( ASIR adaptive statistical iterative reconstruction ). With institutional review board approval, informed consent, and HIPAA compliance, 50 patients (39 men, 11 women) were prospectively included who underwent liver CT. After a portal venous pass with ASIR adaptive statistical iterative reconstruction images, a 60% reduced radiation dose pass was added with MBIR model-based iterative reconstruction images. One reviewer scored ASIR adaptive statistical iterative reconstruction image quality and marked findings. Two additional independent reviewers noted whether marked findings were present on MBIR model-based iterative reconstruction images and assigned scores for relative conspicuity, spatial resolution, image noise, and image quality. Liver and aorta Hounsfield units and image noise were measured. Volume CT dose index and size-specific dose estimate ( SSDE size-specific dose estimate ) were recorded. Qualitative reviewer scores were summarized. Formal statistical inference for signal-to-noise ratio ( SNR signal-to-noise ratio ), contrast-to-noise ratio ( CNR contrast-to-noise ratio ), volume CT dose index, and SSDE size-specific dose estimate was made (paired t tests), with Bonferroni adjustment. Two independent reviewers identified all 136 ASIR adaptive statistical iterative reconstruction image findings (n = 272) on MBIR model-based iterative reconstruction images, scoring them as equal or better for conspicuity, spatial resolution, and image noise in 94.1% (256 of 272), 96.7% (263 of 272), and 99.3% (270 of 272), respectively. In 50 image sets, two reviewers

  2. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8)more » or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.« less

  3. Observer Performance in the Detection and Classification of Malignant Hepatic Nodules and Masses with CT Image-Space Denoising and Iterative Reconstruction

    PubMed Central

    Yu, Lifeng; Li, Zhoubo; Manduca, Armando; Blezek, Daniel J.; Hough, David M.; Venkatesh, Sudhakar K.; Brickner, Gregory C.; Cernigliaro, Joseph C.; Hara, Amy K.; Fidler, Jeff L.; Lake, David S.; Shiung, Maria; Lewis, David; Leng, Shuai; Augustine, Kurt E.; Carter, Rickey E.; Holmes, David R.; McCollough, Cynthia H.

    2015-01-01

    Purpose To determine if lower-dose computed tomographic (CT) scans obtained with adaptive image-based noise reduction (adaptive nonlocal means [ANLM]) or iterative reconstruction (sinogram-affirmed iterative reconstruction [SAFIRE]) result in reduced observer performance in the detection of malignant hepatic nodules and masses compared with routine-dose scans obtained with filtered back projection (FBP). Materials and Methods This study was approved by the institutional review board and was compliant with HIPAA. Informed consent was obtained from patients for the retrospective use of medical records for research purposes. CT projection data from 33 abdominal and 27 liver or pancreas CT examinations were collected (median volume CT dose index, 13.8 and 24.0 mGy, respectively). Hepatic malignancy was defined by progression or regression or with histopathologic findings. Lower-dose data were created by using a validated noise insertion method (10.4 mGy for abdominal CT and 14.6 mGy for liver or pancreas CT) and images reconstructed with FBP, ANLM, and SAFIRE. Four readers evaluated routine-dose FBP images and all lower-dose images, circumscribing liver lesions and selecting diagnosis. The jackknife free-response receiver operating characteristic figure of merit (FOM) was calculated on a per–malignant nodule or per-mass basis. Noninferiority was defined by the lower limit of the 95% confidence interval (CI) of the difference between lower-dose and routine-dose FOMs being less than −0.10. Results Twenty-nine patients had 62 malignant hepatic nodules and masses. Estimated FOM differences between lower-dose FBP and lower-dose ANLM versus routine-dose FBP were noninferior (difference: −0.041 [95% CI: −0.090, 0.009] and −0.003 [95% CI: −0.052, 0.047], respectively). In patients with dedicated liver scans, lower-dose ANLM images were noninferior (difference: +0.015 [95% CI: −0.077, 0.106]), whereas lower-dose FBP images were not (difference −0.049 [95% CI:

  4. Demand for CT scans increases during transition from paediatric to adult care: an observational study from 2009 to 2015.

    PubMed

    Thurley, Pete; Crookdake, Jonathan; Norwood, Mark; Sturrock, Nigel; Fogarty, Andrew W

    2018-02-01

    Avoiding unnecessary radiation exposure is a clinical priority in children and young adults. We aimed to explore demand for CT scans in a busy general hospital with particular interest in the period of transition from paediatric to adult medical care. We used an observational epidemiological study based in a teaching hospital. Data were obtained on numbers and rates of CT scans from 2009 to 2015. The main outcome was age-stratified rates of receiving a CT scan. There were a total of 262,221 CT scans. There was a large step change in the rate of CT scans over the period of transition from paediatric to adult medical care. Individuals aged 10-15 years experienced 6.7 CT scans per 1000 clinical episodes, while those aged 19-24 years experienced 19.8 CT scans per 1000 clinical episodes (p < 0.001). This difference remained significant for all sensitivity analyses. There is almost a threefold increase in rates of CT scans in the two populations before and after the period of transition from paediatric to adult medical care. While we were unable to adjust for case mix or quantify radiation exposure, paediatricians' diagnostic strategies to minimize radiation exposure may have clinical relevance for adult physicians, and hence enable reductions in ionizing radiation to patients. Advances in knowledge: A large increase in rates of CT scans occurs during adolescence, and considering paediatricians' strategies to minimize radiation exposure may enable reductions to all patients.

  5. Utility of Postmortem Autopsy via Whole-Body Imaging: Initial Observations Comparing MDCT and 3.0T MRI Findings with Autopsy Findings

    PubMed Central

    Cha, Jang Gyu; Kim, Dong Hun; Kim, Dae Ho; Paik, Sang Hyun; Park, Jai Soung; Park, Seong Jin; Lee, Hae Kyung; Hong, Hyun Sook; Choi, Duek Lin; Chung, Nak Eun; Lee, Bong Woo; Seo, Joong Seok

    2010-01-01

    Objective We prospectively compared whole-body multidetector computed tomography (MDCT) and 3.0T magnetic resonance (MR) images with autopsy findings. Materials and Methods Five cadavers were subjected to whole-body, 16-channel MDCT and 3.0T MR imaging within two hours before an autopsy. A radiologist classified the MDCT and 3.0T MRI findings into major and minor findings, which were compared with autopsy findings. Results Most of the imaging findings, pertaining to head and neck, heart and vascular, chest, abdomen, spine, and musculoskeletal lesions, corresponded to autopsy findings. The causes of death that were determined on the bases of MDCT and 3.0T MRI findings were consistent with the autopsy findings in four of five cases. CT was useful in diagnosing fatal hemorrhage and pneumothorax, as well as determining the shapes and characteristics of the fractures and the direction of external force. MRI was effective in evaluating and tracing the route of a metallic object, soft tissue lesions, chronicity of hemorrhage, and bone bruises. Conclusion A postmortem MDCT combined with MRI is a potentially powerful tool, providing noninvasive and objective measurements for forensic investigations. PMID:20592923

  6. Comparison of chest CT findings in nontuberculous mycobacterial diseases vs. Mycobacterium tuberculosis lung disease in HIV-negative patients with cavities.

    PubMed

    Kim, Cherry; Park, So Hee; Oh, Sang Young; Kim, Sung-Soo; Jo, Kyung-Wook; Shim, Tae Sun; Kim, Mi Young

    2017-01-01

    This article focuses on the differences between CT findings of HIV-negative patients who have cavities with nontuberculous mycobacteria (NTM) disease and those with Mycobacterium tuberculosis infections (TB). We retrospectively reviewed 128 NTM disease patients (79 males and 49 females) with cavities in chest CT, matched for age and gender with 128 TB patients in the same period. Sputum cultures of all patients were positive for pathogens. Two independent chest radiologists evaluated the characteristics of the largest cavity and related factors. Interobserver agreement was excellent (κ value, 0.853-0.938). Cavity walls in NTM disease were significantly thinner (6.9±4 mm vs 10.9±6 mm, P<0.001) and more even (the ratio of thickness, 2.6±1 vs 3.7±2, P<0.001) than those in TB. The thickening of adjacent pleura next to the cavity was also significantly thicker in NTM than TB (P<0.001). However, in the multivariate analysis, thickening of adjacent pleura was the only significant factor among the representative cavity findings (Odds ratio [OR], 6.49; P<0.001). In addition, ill-defined tree-in-bud nodules (OR, 8.82; P<0.001), number of non-cavitary nodules (≥10mm) (OR, 0.72; P = 0.003), and bronchiectasis in the RUL (OR, 5.3; P = 0.002) were significantly associated ancillary findings with NTM disease in the multivariate analysis. The major cavities in NTM disease generally have thinner and more even walls than those in TB. When cavities are associated with adjacent pleural thickening, ill-defined satellite tree-in-bud nodules, or fewer non-cavitary nodules ≥10 mm, these CT findings are highly suggestive of NTM disease rather than TB.

  7. Biopsy of CT-Occult Bone Lesions Using Anatomic Landmarks for CT Guidance.

    PubMed

    Hillen, Travis J; Talbert, Robert J; Friedman, Michael V; Long, Jeremiah R; Jennings, Jack W; Wessell, Daniel E; Baker, Jonathan C

    2017-07-01

    The purpose of this study is to evaluate the histopathologic diagnostic yield, sample size, procedural time, and dose-length product (DLP) for the biopsy of CT-occult lesions found at MRI or PET or both. A retrospective review of our radiology information system for biopsies of CT-occult lesions using CT guidance from January 1, 2010, through December 31, 2014, was performed and compared with a selection of CT-guided biopsies of CT-evident bone lesions during the same period. The data were then evaluated for diagnostic yield of histopathologic diagnosis, procedural time, use of sedation medication, DLP, and size of specimens obtained. A total of 30 CT-occult biopsies met the inclusion criteria. Twenty-seven of those biopsies had results that were concordant with the patient's primary histopathologic diagnosis, imaging findings, and clinical course. In the CT-evident lesion group, concordant histopathologic abnormalities were identified in 27 of 30 patients. There was a statistically significant increase in number of samples obtained for the CT-evident lesions compared with CT-occult lesions. There was no statistically significant difference in total specimen length, DLP, number of CT scans, procedural time, or use of sedation medication between the CT-occult and CT-evident biopsy groups. Biopsy of CT-occult lesions using anatomic landmarks achieves diagnostic yields similar to those for CT-guided biopsy of CT-evident lesions.

  8. Mandibular fracture caused by periodontal abscess: Radiological, US, CT and MRI findings.

    PubMed

    Mazza, D; Marini, M; Tesei, J; Primicerio, P

    2006-09-01

    Mandibular fracture is a rare but possible outcome of a periodontal abscess. A case of complete fracture of the mandible with abscess infiltrating the surrounding soft tissues is described. The patient reported nor trauma, nor locoregional surgery. Ultrasonography and orthopantomography revealed the fracture of the mandible and the abscess at the masseter muscle. Further preoperative diagnostic examinations included CT and MRI. CT revealed the complete fracture line more clearly; MR the extension of the abscess.

  9. Immediate periodontal bone plate changes induced by rapid maxillary expansion in the early mixed dentition: CT findings

    PubMed Central

    Garib, Daniela Gamba; Menezes, Maria Helena Ocké; da Silva Filho, Omar Gabriel; dos Santos, Patricia Bittencourt Dutra

    2014-01-01

    Objective This study aimed at evaluating buccal and lingual bone plate changes caused by rapid maxillary expansion (RME) in the mixed dentition by means of computed tomography (CT). Methods The sample comprised spiral CT exams taken from 22 mixed dentition patients from 6 to 9 years of age (mean age of 8.1 years) presenting constricted maxillary arch treated with Haas-type expanders. Patients were submitted to spiral CT scan before expansion and after the screw activation period with a 30-day interval between T1 and T2. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal bone crest level of maxillary posterior deciduous and permanent teeth. Changes induced by expansion were evaluated using paired t test (p < 0.05). Results Thickness of buccal and lingual bone plates of posterior teeth remained unchanged during the expansion period, except for deciduous second molars which showed a slight reduction in bone thickness at the distal region of its buccal aspect. Buccal bone dehiscences were not observed in the supporting teeth after expansion. Conclusion RME performed in mixed dentition did not produce immediate undesirable effects on periodontal bone tissues. PMID:25162564

  10. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    PubMed

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P < 0.001) except for mean measurement between CBCT BV/TV and micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment

  11. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    PubMed

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  12. CT detection of facial canal dehiscence and semicircular canal fistula: Comparison with surgical findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuse, Takeo; Tada, Yuichiro; Aoyagi, Masaru

    1996-03-01

    The purpose of this study was to determine the accuracy of high resolution CT (HRCT) in the detection of facial canal dehiscence and semicircular canal fistula, the preoperative evaluation of both of which is clinically very important for ear surgery. We retrospectively reviewed the HRCT findings in 61 patients who underwent mastoidectomy at Yamagata University between 1989 and 1993. The HRCT images were obtained in the axial and semicoronal planes using 1 mm slice thickness and 1 mm intersection gap. In 46 (75%) of the 61 patients, the HRCT image-based assessment of the facial canal dehiscence coincided with the surgicalmore » findings. The data for the facial canal revealed sensitivity of 66% and specificity of 84%. For semicircular canal fistula. in 59 (97%) of the 61 patients, the HRCT image-based assessment and the surgical findings coincided. The image-based assessment in the remaining two patients, who both had massive cholesteatoma, was false-positive. HRCT is useful in the diagnosis of facial canal dehiscence and labyrinthine fistula, but its limitations should also be recognized. 12 refs., 3 figs., 6 tabs.« less

  13. Pulmonary Mucinous Cystadenocarcinoma: Report a Case and Review of CT Findings

    PubMed Central

    Choi, Youn Ah; Han, Joungho; Choi, Joon Young; Kim, Jhingook; Kwon, O Jung; Lee, Kyung Soo

    2013-01-01

    A pulmonary mucinous cystadenocarcinoma is an extremely rare tumor that is considered to be a cystic variant of mucin-producing lung adenocarcinoma. We present a case of pulmonary mucinous cystadenocarcinoma in a 54-year-old woman. Chest CT scans showed a 4.3-cm-sized, lobulated, well-defined, and homogeneous mass in the right middle lobe with peripheral stippled calcifications that demonstrated low-attenuation with no enhancement after contrast administration; 18F-fluorodeoxyglucose (FDG) PET/CT demonstrated mild heterogeneous FDG uptake. The mass was diagnosed as adenocarcinoma with mucin production by transbronchial lung biopsy. Right middle lobectomy was performed, and the pathologic examination disclosed a pulmonary mucinous cystadenocarcinoma. PMID:23483761

  14. Correlation of ultra-low dose chest CT findings with physiologic measures of asbestosis.

    PubMed

    Manners, David; Wong, Patrick; Murray, Conor; Teh, Joelin; Kwok, Yi Jin; de Klerk, Nick; Alfonso, Helman; Franklin, Peter; Reid, Alison; Musk, A W Bill; Brims, Fraser J H

    2017-08-01

    The correlation between ultra low dose computed tomography (ULDCT)-detected parenchymal lung changes and pulmonary function abnormalities is not well described. This study aimed to determine the relationship between ULDCT-detected interstitial lung disease (ILD) and measures of pulmonary function in an asbestos-exposed population. Two thoracic radiologists independently categorised prone ULDCT scans from 143 participants for ILD appearances as absent (score 0), probable (1) or definite (2) without knowledge of asbestos exposure or lung function. Pulmonary function measures included spirometry and diffusing capacity to carbon monoxide (DLCO). Participants were 92% male with a median age of 73.0 years. CT dose index volume was between 0.6 and 1.8 mGy. Probable or definite ILD was reported in 63 (44.1%) participants. Inter-observer agreement was good (k = 0.613, p < 0.001). There was a statistically significant correlation between the ILD score and both forced expiratory volume in 1 second (FEV 1 ) and forced vital capacity (FVC) (r = -0.17, p = 0.04 and r = -0.20, p = 0.02). There was a strong correlation between ILD score and DLCO (r = -0.34, p < 0.0001). Changes consistent with ILD on ULDCT correlate well with corresponding reductions in gas transfer, similar to standard CT. In asbestos-exposed populations, ULDCT may be adequate to detect radiological changes consistent with asbestosis. • Interobserver agreement for the ILD score using prone ULDCT is good. • Prone ULDCT appearances of ILD correlate with changes in spirometric observations. • Prone ULDCT appearances of ILD correlate strongly with changes in gas transfer. • Prone ULDCT may provide sufficient radiological evidence to inform the diagnosis of asbestosis.

  15. Correlation of panoramic radiography and cone beam CT findings in the assessment of the relationship between impacted mandibular third molars and the mandibular canal

    PubMed Central

    Neves, F S; Souza, T C; Almeida, S M; Haiter-Neto, F; Freitas, D Q; Bóscolo, F N

    2012-01-01

    Objectives The aim of this study was to assess the reliability of four panoramic radiographic findings, both individually and in association, in predicting the absence of corticalization between the mandibular canal and the third molar on cone beam CT (CBCT) images. Methods The sample consisted of 72 individuals (142 mandibular third molars) who underwent pre-operative radiographic evaluation before extraction of impacted mandibular third molars. On panoramic radiographs, the most common signs of corticalization (darkening of roots, diversion of mandibular canal, narrowing of mandibular canal and interruption of white line) and the presence or absence of corticalization between the mandibular third molar and the mandibular canal on CBCT images were evaluated. Results Darkening of roots and interruption of white line associated with the absence of corticalization between the mandibular third molar and the mandibular canal on CBCT images were statistically significant, both as isolated findings (p = 0.0001 and p = 0.0006, respectively) and in association (p = 0.002). No statistically significant association was observed for the other panoramic radiographic findings, either individually or in association (p > 0.05). Conclusion Darkening of roots and interruption of white line observed on panoramic radiographs, both as isolated findings and in association, were effective in determining the risk relationship between the tooth roots and the mandibular canal, requiring three-dimensional evaluation of the case. PMID:22282507

  16. Early Head CT Findings Are Associated With Outcomes After Pediatric Out-of-Hospital Cardiac Arrest.

    PubMed

    Starling, Rebecca M; Shekdar, Karuna; Licht, Dan; Nadkarni, Vinay M; Berg, Robert A; Topjian, Alexis A

    2015-07-01

    Head CT after out-of-hospital cardiac arrest is often obtained to evaluate intracranial pathology. Among children admitted to the PICU following pediatric out-of-hospital cardiac arrest, we hypothesized that loss of gray-white matter differentiation and basilar cistern and sulcal effacement are associated with mortality and unfavorable neurologic outcome. Retrospective, cohort study. Single, tertiary-care center PICU. Seventy-eight patients less than 18 years old who survived out-of-hospital cardiac arrest to PICU admission and had a head CT within 24 hours of return of spontaneous circulation were evaluated from July 2005 through May 2012. None. Median time to head CT from return of spontaneous circulation was 3.3 hours (1.0, 6.0). Median patient age was 2.3 years (0.4, 9.5). Thirty-nine patients (50%) survived, of whom 29 (74%) had favorable neurologic outcome. Nonsurvivors were more likely than survivors to have 1) loss of gray-white matter differentiation (Hounsfield unit ratios, 0.96 [0.88, 1.07] vs 1.1 [1.07, 1.2]; p < 0.001), 2) basilar cistern effacement (93% vs 7%; p = 0.001; positive predictive value, 94%; negative predictive value, 59%), and 3) sulcal effacement (100% vs 0%; p ≤ 0.001; positive predictive value, 100%; negative predictive value, 68%). All patients with poor gray-white matter differentiation or sulcal effacement had unfavorable neurologic outcomes. Only one patient with basilar cistern effacement had favorable outcome. Loss of gray-white matter differentiation and basilar cistern effacement and sulcal effacement are associated with poor outcome after pediatric out-of-hospital cardiac arrest. Select patients may have favorable outcomes despite these findings.

  17. Agreement between computed tomography, magnetic resonance imaging, and surgical findings in dogs with degenerative lumbosacral stenosis.

    PubMed

    Suwankong, Niyada; Voorhout, George; Hazewinkel, Herman A W; Meij, Björn P

    2006-12-15

    To assess the extent of agreement between computed tomography (CT), magnetic resonance imaging (MRI), and surgical findings in dogs with degenerative lumbosacral stenosis. Observational study. 35 dogs with degenerative lumbosacral stenosis. Results of preoperative CT and MRI were compared with surgical findings with respect to degree and location of disk protrusion, position of the dural sac, amount of epidural fat, and swelling of spinal nerve roots. A lumbosacral step was seen on radiographic images from 22 of 32 (69%) dogs, on CT images from 23 of 35 (66%) dogs, and on MR images from 21 of 35 (60%) dogs. Most dogs had slight or moderate disk protrusion that was centrally located. There was substantial or near perfect agreement between CT and MRI findings in regard to degree of disk protrusion (kappa, 0.88), location of disk protrusion (0.63), position of the dural sac (0.89), amount of epidural fat (0.72), and swelling of spinal nerve roots (0.60). The degree of agreement between CT and surgical findings and between MRI and surgical findings was moderate in regard to degree and location of disk protrusion (kappa, 0.44 to 0.56) and swelling of spinal nerve roots (0.40 and 0.50). Results indicate that there is a high degree of agreement between CT and MRI findings in dogs with degenerative lumbosacral stenosis but that the degree of agreement between diagnostic imaging findings and surgical findings is lower.

  18. Pulmonary involvement in rheumatoid arthritis: multidetector computed tomography findings.

    PubMed

    Yuksekkaya, Ruken; Celikyay, Fatih; Yilmaz, Ayse; Arslan, Sule; Inanir, Ahmet; Inonu, Handan; Deniz, Caglar

    2013-12-01

    Pulmonary involvement in rheumatoid arthritis (RA) is common and encompasses a large spectrum of disease with different treatment options and prognoses. Therefore, assessment of these patients with multidetector computed tomography (MDCT) is vital. To evaluate the MDCT pulmonary findings of patients with RA and to compare these findings with the clinical status. Chest MDCT scans of 85 patients with RA between 2006-2012 were assessed. One patient with a pulmonary infection was excluded from the study. MDCT findings and distribution of the CT findings were examined, and patients were classified according to the predominant CT pattern. The pulmonary function test (PFT) results and categories, demographic characteristics, and clinical status of some of the patients for whom the results were obtained were evaluated, and the CT findings, PFT results, demographic characteristics, and clinical status were compared. The study group consisted of 20 men (mean age, 58.1 years ± 13.1; range, 15-77 years) and 64 women (mean age, 55.3 years ± 11.5; range, 30-84 years). The most frequent findings were nodules (78.6%) and pleural thickening (48.8%). The most common CT patterns were follicular bronchiolitis (FB) in 28 (33.3%) patients and nodular disease (ND) in 12 (14.3%) others. There was no statistically significant difference between the CT findings and PFT results, and no statistically significant difference was noted in the CT findings between symptomatic and asymptomatic patients. In addition, there were some patients who exhibited no symptoms and/or had abnormal PFT results but had abnormal CT findings. Rheumatoid arthritis is associated with a high frequency of CT findings and CT patterns, with nodules and pleural thickening being the most common CT findings and FB and ND being the most common CT patterns. MDCT identification of patients with RA may be helpful in the evaluation of pulmonary disease, even in patients without symptoms and PFT abnormalities.

  19. Incidence and Association of CT Findings of Ankle Tendon Injuries in Patients Presenting With Ankle and Hindfoot Fractures.

    PubMed

    Golshani, Ashkahn; Zhu, Liang; Cai, Chunyan; Beckmann, Nicholas M

    2017-02-01

    Tendon injuries are a commonly encountered finding in ankle CT examinations performed for fractures. This study was designed to identify the incidence and associations of tendon injuries in ankle CT examinations performed for fractures. A retrospective review was performed of 410 patients who underwent ankle CT during a 6-year period. Tendon injuries were common, seen in 25% of all ankle CT examinations. Tendon subluxation-dislocation accounted for most of the tendon injuries (77 of 196 total injuries). Pilon fractures carried 2.2 times increased risk of tibialis posterior tendon injury (p = 0.0094). Calcaneus fractures carried 11.86 times increased risk of peroneus brevis tendon and 10.71 times increased risk of peroneus longus tendon injury (p < 0.0001). Calcaneus fractures also carried 5.21 times increased risk of flexor hallucis longus tendon injury (p = 0.0024). Talus fracture was associated with injury to all flexor compartment tendons. Talus fractures carried 3.43 times increased risk of tibialis posterior tendon injury (p < 0.0001), 4.51 times increased risk of flexor digitorum longus tendon injury (p = 0.0005), and 6.97 times increased risk of flexor hallucis longus tendon injury (p < 0.0001). Calcaneal fractures are prone to peroneal tendon injury, and talus fractures are prone to flexor tendon injury. In patients with pilon fractures, it is important to look for tibialis posterior tendon injury, specifically for entrapment. Overall, the most common type of injury is tendon malalignment, so it is imperative to know the normal tendon paths and associated bony landmarks to identify tendon injury.

  20. Colorectal Cancer: Cost-effectiveness of Colonoscopy versus CT Colonography Screening with Participation Rates and Costs.

    PubMed

    van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; Goede, S Lucas; Kuipers, Ernst J; Dekker, Evelien; Stoker, Jaap; van Ballegooijen, Marjolein

    2018-06-01

    Purpose To compare the cost-effectiveness of computed tomographic (CT) colonography and colonoscopy screening by using data on unit costs and participation rates from a randomized controlled screening trial in a dedicated screening setting. Materials and Methods Observed participation rates and screening costs from the Colonoscopy or Colonography for Screening, or COCOS, trial were used in a microsimulation model to estimate costs and quality-adjusted life-years (QALYs) gained with colonoscopy and CT colonography screening. For both tests, the authors determined optimal age range and screening interval combinations assuming a 100% participation rate. Assuming observed participation for these combinations, the cost-effectiveness of both tests was compared. Extracolonic findings were not included because long-term follow-up data are lacking. Results The participation rates for colonoscopy and CT colonography were 21.5% (1276 of 5924 invitees) and 33.6% (982 of 2920 invitees), respectively. Colonoscopy was more cost-effective in the screening strategies with one or two lifetime screenings, whereas CT colonography was more cost-effective in strategies with more lifetime screenings. CT colonography was the preferred test for willingness-to-pay-thresholds of €3200 per QALY gained and higher, which is lower than the Dutch willingness-to-pay threshold of €20 000. With equal participation, colonoscopy was the preferred test independent of willingness-to-pay thresholds. The findings were robust for most of the sensitivity analyses, except with regard to relative screening costs and subsequent participation. Conclusion Because of the higher participation rates, CT colonography screening for colorectal cancer is more cost-effective than colonoscopy screening. The implementation of CT colonography screening requires previous satisfactory resolution to the question as to how best to deal with extracolonic findings. © RSNA, 2018 Online supplemental material is available for

  1. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers.

    PubMed

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) MATERIALS AND METHODS: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7±8.7years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Each inter-observer agreement was rated as substantial (Sub-CT: κ=0.69, p<0.0001; DE-CT: κ=0.64, p<0.0001; SPECT/CT: κ=0.64, p<0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r=0.72, p=0.0001; DE-CT: r=0.74, p<0.0001; SPECT/CT: r=0.66, p=0.0006). Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET/CT) Findings in an Unusual Case of Multiple Myeloma Presenting with a Large Extra-Axial Intracranial Mass.

    PubMed

    Ayaz, Sevin; Ayaz, Ümit Yaşar

    2016-01-01

    We aimed to present unusual cranial FDG PET/CT findings of a 56-year-old female with multiple myeloma (MM). Plain CT images revealed a lytic lesion in the right parietal bone, filled with an oval-shaped, large, extra-axial, extradural, intracranial mass which measured 75×75×40 mm and had smooth borders. The right parietal lobe was compressed by the mass. The maximum standardized uptake value (SUV max ) of the mass lesion was 8.94 on FDG PET/CT images. Multiple lytic lesions with an increased uptake were also detected in other calvarial bones, in several vertebras and in the proximal left femur. After seven months, a control FDG PET/CT following radiotherapy and chemotherapy revealed almost complete regression of the right parietal extra-axial mass lesion. The number, size and metabolism of lytic lesions in other bones also decreased. FDG PET/CT was useful for an initial evaluation of MM lesions and was effective in monitoring the response of these lesions to therapy.

  3. Sensor performance considerations for aviation weather observations for the NOAA Consolidated Observations Requirements List (CORL CT-AWX)

    NASA Astrophysics Data System (ADS)

    Murray, John; Helms, David; Miner, Cecilia

    2008-08-01

    Airspace system demand is expected to increase as much as 300 percent by the year 2025 and the Next Generation Air Transportation System (NextGen) is being developed to accommodate the super-density operations that this will entail. Concomitantly, significant improvements in observations and forecasting are being undertaken to support NextGen which will require greatly improved and more uniformly applied data for aviation weather hazards and constraints which typically comprise storm-scale and microscale observables. Various phenomena are associated with these hazards and constraints such as convective weather, in-flight icing, turbulence, and volcanic ash as well as more mundane aviation parameters such as cloud tops and bases and fuel-freeze temperatures at various flight levels. Emerging problems for aviation in space weather and the environmental impacts of aviation are also occurring at these scales. Until recently, the threshold and objective observational requirements for these observables had not been comprehensively documented in a single, authoritative source. Scientists at NASA and NOAA have recently completed this task and have established baseline observational requirements for the Next Generation Air Transportation System (NextGen) and expanded and updated the NOAA Consolidated Observations Requirements List (CORL) for Aviation (CT-AWX) to better inform National Weather Service investments for current and future observing systems. This paper describes the process and results of this effort. These comprehensive aviation observation requirements will now be used to conduct gap analyses for the aviation component of the Integrated Earth Observing System and to inform the investment strategies of the FAA, NASA, and NOAA that are needed to develop the observational architecture to support NextGen and other users of storm and microscale observations.

  4. Early Head CT Findings Are Associated With Outcomes After Pediatric Out-of-Hospital Cardiac Arrest

    PubMed Central

    Starling, Rebecca M.; Shekdar, Karuna; Licht, Dan; Nadkarni, Vinay M.; Berg, Robert A.; Topjian, Alexis A.

    2015-01-01

    Objectives Head CT after out-of-hospital cardiac arrest is often obtained to evaluate intracranial pathology. Among children admitted to the PICU following pediatric out-of-hospital cardiac arrest, we hypothesized that loss of gray-white matter differentiation and basilar cistern and sulcal effacement are associated with mortality and unfavorable neurologic outcome. Design Retrospective, cohort study. Setting Single, tertiary-care center PICU. Patients Seventy-eight patients less than 18 years old who survived out-of-hospital cardiac arrest to PICU admission and had a head CT within 24 hours of return of spontaneous circulation were evaluated from July 2005 through May 2012. Interventions None. Measurements and Main Results Median time to head CT from return of spontaneous circulation was 3.3 hours (1.0, 6.0). Median patient age was 2.3 years (0.4, 9.5). Thirty-nine patients (50%) survived, of whom 29 (74%) had favorable neurologic outcome. Nonsurvivors were more likely than survivors to have 1) loss of gray-white matter differentiation (Hounsfield unit ratios, 0.96 [0.88, 1.07] vs 1.1 [1.07, 1.2]; p < 0.001), 2) basilar cistern effacement (93% vs 7%; p = 0.001; positive predictive value, 94%; negative predictive value, 59%), and 3) sulcal effacement (100% vs 0%; p ≤ 0.001; positive predictive value, 100%; negative predictive value, 68%). All patients with poor gray-white matter differentiation or sulcal effacement had unfavorable neurologic outcomes. Only one patient with basilar cistern effacement had favorable outcome. Conclusions Loss of gray-white matter differentiation and basilar cistern effacement and sulcal effacement are associated with poor outcome after pediatric out-of-hospital cardiac arrest. Select patients may have favorable outcomes despite these findings. PMID:25844694

  5. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study

    PubMed Central

    Grosser, Oliver S.; Kupitz, Dennis; Ruf, Juri; Czuczwara, Damian; Steffen, Ingo G.; Furth, Christian; Thormann, Markus; Loewenthal, David; Ricke, Jens; Amthauer, Holger

    2015-01-01

    Background Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. Methodology/Principal Findings Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001). Conclusion/Significance In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality. PMID:26390216

  6. Ovarian torsion: diagnostic features on CT and MRI with pathologic correlation.

    PubMed

    Duigenan, Shauna; Oliva, Esther; Lee, Susanna I

    2012-02-01

    The CT and MRI features of ovarian torsion are illustrated with gross pathologic correlation. Ovarian enlargement with or without an underlying mass is the finding most frequently associated with torsion, but it is nonspecific. A twisted pedicle, although not often detected on imaging, is pathognomonic when seen. Subacute ovarian hemorrhage and abnormal enhancement is usually seen, and both features show characteristic patterns on CT and MRI. Ipsilateral uterine deviation can also be seen. Diagnostic pitfalls that may mimic ovarian torsion and observations for discriminating them are discussed.

  7. Finding new sub-stellar co-moving companion candidates - the case of CT Cha

    NASA Astrophysics Data System (ADS)

    Schmidt, Tobias; Neuhäuser, Ralph

    2008-05-01

    We have searched for close and faint companions around T Tauri stars in the Chamaeleon star forming region. Two epochs of direct imaging data were taken with the VLT Adaptive Optics instrument NaCo in February 2006 and March 2007 in Ks band for the classical T Tauri star CT Cha together with a Hipparcos binary for astrometric calibration. Moreover a J band image was taken in March 2007 to get color information. We found CT Cha to have a very faint companion (Ks0=14.6 mag) of 2.67” separation corresponding to 440AU. We show that CT Cha A and the faint object form a common proper motion pair and that the companion is not a non-moving background object (with 4σ significance).

  8. Binding and thermodynamics of REV peptide-ctDNA interaction.

    PubMed

    Upadhyay, Santosh Kumar

    2017-03-01

    The thermodynamics of DNA-ligand binding is important as it provides useful information to understand the details of binding processes. HIV-1 REV response element (RRE) located in the env coding region of the viral genome is reported to be well conserved across different HIV-1 isolates. In this study, the binding characteristics of Calf thymus DNA (ctDNA) and REV peptide from HIV-1 were investigated using spectroscopic (UV-visible, fluorescence, and circular dichroism (CD)) and isothermal titration calorimetric (ITC) techniques. Thermal stability and ligand binding properties of the ctDNA revealed that native ctDNA had a T m of 75.5 °C, whereas the ctDNA-REV peptide complex exhibited an incremental shift in the T m by 8 °C, indicating thermal stability of the complex. CD data indicated increased ellipticity due to large conformational changes in ctDNA molecule upon binding with REV peptide and two binding stoichiometric modes are apparent. The ctDNA experienced condensation due to large conformational changes in the presence of REV peptide and positive B→Ψ transition was observed at higher molar charge ratios. Fluorescence studies performed at several ligand concentrations revealed a gradual decrease in the fluorescence intensity of EtBr-bound ctDNA in response to increasing ligand concentrations. The fluorescence data further confirmed two stoichiometric modes of binding for ctDNA-REV peptide complex as previously observed with CD studies. The binding enthalpies were determined using ITC in the temperature range of 293 K-308 K. The ITC binding isotherm was exothermic at all temperatures examined, with low ΔH values indicating that the ctDNA-REV peptide interaction is driven largely by entropy. The heat capacity change (ΔC p ) was insignificant, an unusual finding in the area of DNA-peptide interaction studies. The variation in the values obtained for ΔH, ΔS, and ΔG with temperature further suggests that ctDNA-REV peptide interaction is entropically

  9. Correlation Between Findings of Multislice Helical Computed Tomography (CT), Endoscopic Examinations, Endovascular Procedures, and Surgery in Patients with Symptoms of Acute Gastrointestinal Bleeding.

    PubMed

    Konecki, Dariusz; Grabowska-Derlatka, Laretta; Pacho, Ryszard; Rowiński, Olgierd

    2017-01-01

    Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding.

  10. Initial observations of electronic medical record usage during CT and MRI interpretation: Frequency of use and impact on workflow.

    PubMed

    Lin, Abraham; Harris, Mitchell; Zalis, Michael

    2010-07-01

    Electronic medical record (EMR) systems permit integration of contextual nonimaging EMR data into examination interpretation; however, the extra effort required to search and review these nonradiologic data are not well characterized. We assessed the gross frequency and pattern of EMR usage in the interpretation of diagnostic CT and MRI examinations. We defined nonradiologic EMR data as laboratory data, nonimaging specialty report, clinical note, and administrative data not available on PACS. For abdominal, neuroradiologic, and musculoskeletal CT and MRI, we prospectively recorded the time required for image analysis (including prior imaging studies and their reports), nonradiologic EMR use, and initial report drafting by fellows and staff in randomized sessions. We assessed EMR use as a fraction of work activity and according to technique, subspecialty, inpatient status, and radiologist experience. We observed 372 CT and MRI interpretations by 33 radiologists. For CT, radiologists used the EMR in 34% of abdominal, 57% of neuroradiologic, and 38% of musculoskeletal interpretations. For MRI, EMR was used in 73% of abdominal, 56% of neuroradiologic, and 33% of musculoskeletal interpretations. For CT, EMR usage comprised 18%, 14%, and 18% of diagnostic effort (image analysis plus EMR use) for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively; for MRI, EMR usage comprised 21%, 16%, and 15% of diagnostic effort for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively. Frequency of EMR use was significantly greater for neuroradiology CT and abdominal MRI (p < 0.05, Fisher's test). EMR usage was not consistently related to inpatient status for CT or radiologist experience. For CT and MRI interpretation, EMR usage is frequent and comprises a significant fraction of diagnostic effort.

  11. Computed tomography findings of acute gastric volvulus.

    PubMed

    Millet, Ingrid; Orliac, Celine; Alili, Chakib; Guillon, Françoise; Taourel, Patrice

    2014-12-01

    To assess the diagnostic performance of CT signs of gastric volvulus in both confirmed cases and control subjects. We retrospectively reviewed CT findings in 10 patients with surgically confirmed acute gastric volvulus and 20 control subjects with gastric distension. Two radiologists independently evaluated CT images for risk factors of gastric volvulus, direct findings of gastric volvulus by assessing gastric dilatation, the presence of an antropyloric transition point, the respective position of the different stomach segments and of the greater and lesser curvatures, stenosis of the gastric segments through the oesophageal hiatus and for findings of gastric ischemia. The sensitivity and specificity of each finding were calculated. The most sensitive direct signs of gastric volvulus were an antropyloric transition point without any abnormality at the transition zone and the antrum at the same level or higher than the fundus. The presence of both these two findings as diagnostic criteria of gastric volvulus had 100% sensitivity and specificity for the diagnosis of gastric volvulus. There was no association between CT signs of ischemia and final bowel ischemia at pathology. CT is both highly sensitive and specific for diagnosing acute gastric volvulus. CT is highly reliable for diagnosing acute gastric volvulus with two findings. The two signs are gastropyloric transition zone and abnormal location of the antrum. This allows fast surgical management of this emergency.

  12. Measurement of myocardial extracellular volume fraction by using equilibrium contrast-enhanced CT: validation against histologic findings.

    PubMed

    Bandula, Steve; White, Steven K; Flett, Andrew S; Lawrence, David; Pugliese, Francesca; Ashworth, Michael T; Punwani, Shonit; Taylor, Stuart A; Moon, James C

    2013-11-01

    To develop and validate equilibrium contrast material-enhanced computed tomography (CT) to measure myocardial extracellular volume (ECV) fraction by using a histologic reference standard and to compare equilibrium CT with equilibrium contrast-enhanced magnetic resonance (MR) imaging. A local ethics committee approved the study, and all subjects gave fully informed written consent. An equilibrium CT protocol was developed using iohexol at 300 mg of iodine per milliliter (bolus of 1 mg per kilogram of body weight administered at a rate of 3 mL/sec, followed immediately by an infusion of 1.88 mL/kg per hour with CT imaging before and at 25 minutes after injection of bolus of contrast agent) and ECV within the myocardial septum measured using both equilibrium CT and equilibrium MR imaging in patients with severe aortic stenosis. Biopsy samples of the myocardial septum collected during valve replacement surgery were used for histologic quantification of extracellular fibrosis with picrosirius red staining. Equilibrium CT- and equilibrium MR imaging-derived ECV measurements were compared with histologically quantified fibrosis by using Pearson correlation. Agreement between equilibrium CT and equilibrium MR imaging was assessed by using Bland-Altman comparison. Twenty-three patients (16 male, seven female; mean age, 70.8 years; standard deviation, 8.3) were recruited. The mean percentage of histologic fibrosis was 18% (intersubject range, 5%-40%). There was a significant correlation between both equilibrium CT- and equilibrium MR imaging-derived ECV and percentage of histologic fibrosis (r = 0.71 [P < .001] and r = 0.84 [P < .0001], respectively). Equilibrium CT-derived ECV was significantly correlated to equilibrium MR imaging-derived ECV (r = 0.73). ECV measured by using equilibrium CT in patients with aortic stenosis correlates with histologic quantification of myocardial fibrosis and with ECV derived by using equilibrium MR imaging. RSNA, 2013

  13. Chest X-ray and chest CT findings in patients diagnosed with pulmonary tuberculosis following solid organ transplantation: a systematic review.

    PubMed

    Giacomelli, Irai Luis; Schuhmacher Neto, Roberto; Marchiori, Edson; Pereira, Marisa; Hochhegger, Bruno

    2018-04-01

    The objective of this systematic review was to select articles including chest X-ray or chest CT findings in patients who developed pulmonary tuberculosis following solid organ transplantation (lung, kidney, or liver). The following search terms were used: "tuberculosis"; "transplants"; "transplantation"; "mycobacterium"; and "lung". The databases used in this review were PubMed and the Brazilian Biblioteca Virtual em Saúde (Virtual Health Library). We selected articles in English, Portuguese, or Spanish, regardless of the year of publication, that met the selection criteria in their title, abstract, or body of text. Articles with no data on chest CT or chest X-ray findings were excluded, as were those not related to solid organ transplantation or pulmonary tuberculosis. We selected 29 articles involving a collective total of 219 patients. The largest samples were in studies conducted in Brazil and South Korea (78 and 35 patients, respectively). The imaging findings were subdivided into five common patterns. The imaging findings varied depending on the transplanted organ in these patients. In liver and lung transplant recipients, the most common pattern was the classic one for pulmonary tuberculosis (cavitation and "tree-in-bud" nodules), which is similar to the findings for pulmonary tuberculosis in the general population. The proportion of cases showing a miliary pattern and lymph node enlargement, which is most similar to the pattern seen in patients coinfected with tuberculosis and HIV, was highest among the kidney transplant recipients. Further studies evaluating clinical data, such as immunosuppression regimens, are needed in order to improve understanding of the distribution of these imaging patterns in this population.

  14. Subjective and objective comparisons of image quality between ultra-high-resolution CT and conventional area detector CT in phantoms and cadaveric human lungs.

    PubMed

    Yanagawa, Masahiro; Hata, Akinori; Honda, Osamu; Kikuchi, Noriko; Miyata, Tomo; Uranishi, Ayumi; Tsukagoshi, Shinsuke; Tomiyama, Noriyuki

    2018-05-29

    To compare the image quality of the lungs between ultra-high-resolution CT (U-HRCT) and conventional area detector CT (AD-CT) images. Image data of slit phantoms (0.35, 0.30, and 0.15 mm) and 11 cadaveric human lungs were acquired by both U-HRCT and AD-CT devices. U-HRCT images were obtained with three acquisition modes: normal mode (U-HRCT N : 896 channels, 0.5 mm × 80 rows; 512 matrix), super-high-resolution mode (U-HRCT SHR : 1792 channels, 0.25 mm × 160 rows; 1024 matrix), and volume mode (U-HRCT SHR-VOL : non-helical acquisition with U-HRCT SHR ). AD-CT images were obtained with the same conditions as U-HRCT N . Three independent observers scored normal anatomical structures (vessels and bronchi), abnormal CT findings (faint nodules, solid nodules, ground-glass opacity, consolidation, emphysema, interlobular septal thickening, intralobular reticular opacities, bronchovascular bundle thickening, bronchiectasis, and honeycombing), noise, artifacts, and overall image quality on a 3-point scale (1 = worst, 2 = equal, 3 = best) compared with U-HRCT N . Noise values were calculated quantitatively. U-HRCT could depict a 0.15-mm slit. Both U-HRCT SHR and U-HRCT SHR-VOL significantly improved visualization of normal anatomical structures and abnormal CT findings, except for intralobular reticular opacities and reduced artifacts, compared with AD-CT (p < 0.014). Visually, U-HRCT SHR-VOL has less noise than U-HRCT SHR and AD-CT (p < 0.00001). Quantitative noise values were significantly higher in the following order: U-HRCT SHR (mean, 30.41), U-HRCT SHR-VOL (26.84), AD-CT (16.03), and U-HRCT N (15.14) (p < 0.0001). U-HRCT SHR and U-HRCT SHR-VOL resulted in significantly higher overall image quality than AD-CT and were almost equal to U-HRCT N (p < 0.0001). Both U-HRCT SHR and U-HRCT SHR-VOL can provide higher image quality than AD-CT, while U-HRCT SHR-VOL was less noisy than U-HRCT SHR . • Ultra-high-resolution CT (U-HRCT) can improve spatial resolution. • U

  15. Association between Smoking and the Progression of Computed Tomography Findings in Chronic Pancreatitis.

    PubMed

    Lee, Jeong Woo; Kim, Ho Gak; Lee, Dong Wook; Han, Jimin; Kwon, Hyuk Yong; Seo, Chang Jin; Oh, Ji Hye; Lee, Joo Hyoung; Jung, Jin Tae; Kwon, Joong Goo; Kim, Eun Young

    2016-05-23

    Smoking and alcohol intake are two wellknown risk factors for chronic pancreatitis. However, there are few studies examining the association between smoking and changes in computed tomography (CT) findings in chronic pancreatitis. The authors evaluated associations between smoking, drinking and the progression of calcification on CT in chronic pancreatitis. In this retrospective study, 59 patients with chronic pancreatitis who had undergone initial and follow-up CT between January 2002 and September 2010 were included. Progression of calcification among CT findings was compared according to the amount of alcohol intake and smoking. The median duration of followup was 51.6 months (range, 17.1 to 112.7 months). At initial CT findings, there was pancreatic calcification in 35 patients (59.3%). In the follow-up CT, progression of calcification was observed in 37 patients (62.7%). Progression of calcification was more common in smokers according to the multivariate analysis (odds ratio [OR], 9.987; p=0.006). The amount of smoking was a significant predictor for progression of calcification in the multivariate analysis (OR, 6.051 in less than 1 pack per day smokers; OR, 36.562 in more than 1 pack per day smokers; p=0.008). Continued smoking accelerates pancreatic calcification, and the amount of smoking is associated with the progression of calcification in chronic pancreatitis.

  16. Association between Smoking and the Progression of Computed Tomography Findings in Chronic Pancreatitis

    PubMed Central

    Lee, Jeong Woo; Kim, Ho Gak; Lee, Dong Wook; Han, Jimin; Kwon, Hyuk Yong; Seo, Chang Jin; Oh, Ji Hye; Lee, Joo Hyoung; Jung, Jin Tae; Kwon, Joong Goo; Kim, Eun Young

    2016-01-01

    Background/Aims Smoking and alcohol intake are two well-known risk factors for chronic pancreatitis. However, there are few studies examining the association between smoking and changes in computed tomography (CT) findings in chronic pancreatitis. The authors evaluated associations between smoking, drinking and the progression of calcification on CT in chronic pancreatitis. Methods In this retrospective study, 59 patients with chronic pancreatitis who had undergone initial and follow-up CT between January 2002 and September 2010 were included. Progression of calcification among CT findings was compared according to the amount of alcohol intake and smoking. Results The median duration of follow-up was 51.6 months (range, 17.1 to 112.7 months). At initial CT findings, there was pancreatic calcification in 35 patients (59.3%). In the follow-up CT, progression of calcification was observed in 37 patients (62.7%). Progression of calcification was more common in smokers according to the multivariate analysis (odds ratio [OR], 9.987; p=0.006). The amount of smoking was a significant predictor for progression of calcification in the multivariate analysis (OR, 6.051 in less than 1 pack per day smokers; OR, 36.562 in more than 1 pack per day smokers; p=0.008). Conclusions Continued smoking accelerates pancreatic calcification, and the amount of smoking is associated with the progression of calcification in chronic pancreatitis. PMID:26601825

  17. Artificial neural networks: Predicting head CT findings in elderly patients presenting with minor head injury after a fall.

    PubMed

    Dusenberry, Michael W; Brown, Charles K; Brewer, Kori L

    2017-02-01

    To construct an artificial neural network (ANN) model that can predict the presence of acute CT findings with both high sensitivity and high specificity when applied to the population of patients≥age 65years who have incurred minor head injury after a fall. An ANN was created in the Python programming language using a population of 514 patients ≥ age 65 years presenting to the ED with minor head injury after a fall. The patient dataset was divided into three parts: 60% for "training", 20% for "cross validation", and 20% for "testing". Sensitivity, specificity, positive and negative predictive values, and accuracy were determined by comparing the model's predictions to the actual correct answers for each patient. On the "cross validation" data, the model attained a sensitivity ("recall") of 100.00%, specificity of 78.95%, PPV ("precision") of 78.95%, NPV of 100.00%, and accuracy of 88.24% in detecting the presence of positive head CTs. On the "test" data, the model attained a sensitivity of 97.78%, specificity of 89.47%, PPV of 88.00%, NPV of 98.08%, and accuracy of 93.14% in detecting the presence of positive head CTs. ANNs show great potential for predicting CT findings in the population of patients ≥ 65 years of age presenting with minor head injury after a fall. As a good first step, the ANN showed comparable sensitivity, predictive values, and accuracy, with a much higher specificity than the existing decision rules in clinical usage for predicting head CTs with acute intracranial findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Clear-Cell Meningioma: CT and MR Imaging Findings in Two Cases Involving the Spinal Canal and Cerebellopontine Angle

    PubMed Central

    Yu, Ki Bong; Kim, Hyung Jin; Suh, Chang Hae; Park, Hyung Chun; Kim, Eun Young; Han, Hye Seung

    2002-01-01

    Clear-cell meningioma is a rare subtype of meningioma which occurs at a younger age and has a higher recurrence rate than other subtypes. We report two cases of clear-cell meningioma, one in the thoracolumbar spinal canal and the other in the cerebellopontine angle. Though the CT and MR imaging findings were not different from those of ordinary meningioma, after surgical removal the condition recurred repeatedly in the patient with spinal canal involvement. PMID:12087202

  19. Primary central nervous system lymphoma with lymphomatosis cerebri in an immunocompetent child: MRI and 18F-FDG PET-CT findings.

    PubMed

    Jain, Tarun K; Sharma, Punit; Suman, Sudhir K C; Faizi, Nauroze A; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Primary central nervous system lymphoma (PCNSL) is extremely rare in immunocompetent children. We present the magnetic resonance imaging (MRI) and (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography-computed tomography (PET-CT) findings of such a case in a 14-year old immunocompetent boy. In this patient, PCNSL was associated with lymphomatosis cerebri. Familiarity with the findings of this rare condition will improve the diagnostic confidence of the nuclear radiologist and avoid misdiagnosis. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  20. Correlation Between Findings of Multislice Helical Computed Tomography (CT), Endoscopic Examinations, Endovascular Procedures, and Surgery in Patients with Symptoms of Acute Gastrointestinal Bleeding

    PubMed Central

    Konecki, Dariusz; Pacho, Ryszard; Rowiński, Olgierd

    2017-01-01

    Summary Background Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. Material/Methods The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. Results The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. Conclusions CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding. PMID:29662594

  1. Unenhanced CT findings can predict the development of urinary calculi in stone-free patients.

    PubMed

    Ciudin, Alexandru; Luque Galvez, Maria Pilar; Salvador Izquierdo, Rafael; Franco de Castro, Agustin; Garcia-Cruz, Eduardo; Alcover García, Juan; Alvarez-Vijande García, Jose Ricardo; Nicolau, Carlos; Alcaraz Asensio, Antonio

    2012-09-01

    To determine if calcium deposits in the papillae can be identified by unenhanced computed tomography (uCT) even before renal stones develop. A retrospective review of 413 patients with calculi identified 31 patients (stone-forming group) with a history of urinary tract calculi with a calculus demonstrated by uCT and a stone-free uCT before calculi had developed. The control group (n = 31) was composed of live kidney donors with no history of calculi and a stone-free uCT. CT attenuation was measured in all CTs using two regions of interest of 0.05 cm(2) and 0.1 cm(2) over the tip and the neighbouring area of the papillae. Student's and Wilcoxon t-tests were used for comparing results in the two groups. The attenuation of the tip of the papilla was higher in the stone-forming group when compared to the controls after (45.2 HU versus 32.1 HU, P = 0.001) and even before frank calculi had developed (44.2 HU versus 32.1 HU, P = 0.003). There was no significant difference in papillary attenuation in the stone group before and after calculi had developed (45.2 HU versus 44.2 HU, P = 0.82). Stone-forming patients exhibit higher papillary density even before calculi develop. This could define a population at risk of developing calculi.

  2. Tuberculous peritonitis: CT appearance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanson, R.D.; Hunter, T.B.

    1985-05-01

    Rare, sporadic cases of tuberculous peritonitis do occur in the United States and other advanced countries. Because there are few descriptions of the CT appearance of the peritoneal forms of tuberculous (TB), this report illustrates a case of tuberculous peritonitis with prominent CT findings and discusses the differentiation of this entity from other, more common diseases.

  3. Fatal pleural mesothelioma in Japan (2003-2008): evaluation of computed tomography findings.

    PubMed

    Kato, Katsuya; Gemba, Kenichi; Fujimoto, Nobukazu; Aoe, Keisuke; Takeshima, Yukio; Inai, Kouki; Kishimoto, Takumi

    2016-06-01

    The purpose of this study was to clarify the characteristic findings of mesothelioma at the time of diagnosis, and determine precautions and guidelines for diagnosing mesothelioma early in imaging studies. Overall, 327 patients with pleural mesothelioma were selected from 6030 patients who died of mesothelioma between 2003 and 2008 in Japan. Their imaging findings were examined retrospectively. Plaques were found in 35 % of computed tomography (CT) scans. Asbestosis, diffuse pleural thickening, and rounded atelectasis were found in only seven (2 %), five (2 %), and two cases (1 %), respectively. Pleural thickening findings on CT scans were classified into four stages: no irregularity, mild irregularity, high irregularity, and mass formation. Overall, 18 % of cases did not show a clear irregularity. Localized thickening was observed in the mediastinal (77 %) and basal (76 %) pleura and in the interlobar fissure (49 %). Eight percent of cases did not have any thickening in these three areas. Upon examination of the CT scans at diagnosis, 18 % of mesothelioma cases did not show a clear irregularity. When diagnosing pleural effusion of unknown etiology, it is necessary to consider the possibility of mesothelioma even when no plaque and pleural irregularity are observed.

  4. CT manifestations of peritoneal carcinomatosis.

    PubMed

    Walkey, M M; Friedman, A C; Sohotra, P; Radecki, P D

    1988-05-01

    Seventy-three abdominopelvic contrast-enhanced CT scans obtained in 60 patients with peritoneal tumor spread were reviewed retrospectively to determine the CT signs of peritoneal malignancy. Ascites was present in 54 studies (74%) and was the most common CT finding. Loculation of the fluid occurred in 25 (46%) of these. In nine (17%) of the 54, a new finding, absence of cul-de-sac fluid in the presence of generalized ascites, was noted. Parietal peritoneal thickening with contrast enhancement of the peritoneum, making the peritoneum visible as a thin line along the abdominal wall, was present in 45 (62%) of studies. This is believed to represent confluent peritoneal metastases. Small-bowel involvement was present in half of the cases (wall thickening and irregularity with or without obstruction). Tumor involvement of the omentum was visible as soft-tissue permeation of fat, enhancing nodules, and/or an omental cake. Of the 26 patients without a previously known malignancy, identification of the primary tumor in addition to peritoneal carcinomatosis was possible in 13 (50%). Appreciation of the spectrum of CT findings in peritoneal carcinomatosis is essential for accurate evaluation of scans in patients with abdominopelvic malignancies.

  5. Congenital bronchopulmonary malformation: CT histopathological correlation.

    PubMed

    Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela

    2016-12-01

    This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.

  6. Study Finds Small Increase in Cancer Risk after Childhood CT Scans

    Cancer.gov

    A study published in the June 6, 2012, issue of The Lancet shows that radiation exposure from computed tomography (CT) scans in childhood results in very small but increased risks of leukemia and brain tumors in the first decade after exposure.

  7. Paratracheal air cysts: a common finding on routine CT examinations of the cervical spine and neck that may mimic pneumomediastinum in patients with traumatic injuries.

    PubMed

    Buterbaugh, J E; Erly, W K

    2008-06-01

    Collections of extraluminal paratracheal gas may be present on CT images of the neck and cervical spine and the radiologist may question whether this is related to a pathologic process. This study is designed to demonstrate the appearance, clinical presentation, and prevalence of paratracheal air cysts, which, on CT examinations of the neck, can mimic abnormal extraluminal air. From January 1, 2005, through May 22, 2005, a total of 702 CT examinations of the cervical spine or soft tissue of the neck were reviewed. All examinations were at 2- to 5-mm thickness. Sagittal and coronal reconstructions were available for review, if necessary. Paratracheal air cysts were evaluated for size; the presence of visible communication with the trachea; association with pneumothorax, pneumomediastinum, or subcutaneous emphysema; and association with findings of emphysematous changes in the lung apices. Patient demographics of age, sex, and whether the patient had sustained a traumatic injury were also collected. Of the 702 patients evaluated, 26 (3.7%) had paratracheal air cysts, all of which were found on the right, at the level of the thoracic inlet. Ages of the patients ranged from 15 to 74 years. In 9 (34.6%) of the patients, a direct communication with the trachea was seen. Sizes of the paratracheal air cysts ranged from 1 x 2 mm to 10 x 15 mm. No association was found with CT findings of emphysema in the lung apices, abnormal soft tissue air, or trauma. Right paratracheal air cysts are a common CT finding that occur in a predictable location. In the setting of trauma, these characteristic structures can mimic pneumomediastinum and are seen in approximately 3% to 4% of the US population. The cause is unclear but may be either congenital or an acquired phenomenon, given that they are often seen in both children and adults. We found no association with either trauma or the presence of emphysematous changes in the lung apices.

  8. 320-Row wide volume CT significantly reduces density heterogeneity observed in the descending aorta: comparisons with 64-row helical CT.

    PubMed

    Yamashiro, Tsuneo; Miyara, Tetsuhiro; Honda, Osamu; Kamiya, Ayano; Tanaka, Yuko; Murayama, Sadayuki

    2014-01-01

    The aim of this study was to compare density heterogeneity on wide volume (WV) scans with that on helical CT scans. 22 subjects underwent chest CT using 320-WV and 64-helical modes. Density heterogeneity of the descending aorta was evaluated quantitatively and qualitatively. At qualitative assessment, the heterogeneity was judged to be smaller on WV scans than on helical scans (p<0.0001). Mean changes in aortic density between two contiguous slices were 1.64 HU (3.40%) on WV scans and 2.29 HU (5.19%) on helical scans (p<0.0001). CT density of thoracic organs is more homogeneous and reliable on WV scans than on helical scans. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Incremental Role of Mammography in the Evaluation of Gynecomastia in Men Who Have Undergone Chest CT.

    PubMed

    Sonnenblick, Emily B; Salvatore, Mary; Szabo, Janet; Lee, Karen A; Margolies, Laurie R

    2016-08-01

    The purpose of this study was to determine whether additional breast imaging is clinically valuable in the evaluation of patients with gynecomastia incidentally observed on CT of the chest. In a retrospective analysis, 62 men were identified who had a mammographic diagnosis of gynecomastia and had also undergone CT within 8 months (median, 2 months). We compared the imaging findings of both modalities and correlated them with the clinical outcome. Gynecomastia was statistically significantly larger on mammograms than on CT images; however, there was a high level of concordance in morphologic features and distribution of gynecomastia between mammography and CT. In only one case was gynecomastia evident on mammographic but not CT images, owing to cachexia. Two of the 62 men had ductal carcinoma, which was obscured by gynecomastia. Both of these patients had symptoms suggesting malignancy. The appearance of gynecomastia on CT scans and mammograms was highly correlated. Mammography performed within 8 months of CT is unlikely to reveal cancer unless there is a suspicious clinical finding or a breast mass eccentric to the nipple. Men with clinical symptoms of gynecomastia do not need additional imaging with mammography to confirm the diagnosis if they have undergone recent cross-sectional imaging.

  10. Lightweight Expression of Granular Objects (LEGO) Content Modeling Using the SNOMED CT Observables Model to Represent Nursing Assessment Data.

    PubMed

    Johnson, Christie

    2016-01-01

    This poster presentation presents a content modeling strategy using the SNOMED CT Observable Model to represent large amounts of detailed clinical data in a consistent and computable manner that can support multiple use cases. Lightweight Expression of Granular Objects (LEGOs) represent question/answer pairs on clinical data collection forms, where a question is modeled by a (usually) post-coordinated SNOMED CT expression. LEGOs transform electronic patient data into a normalized consumable, which means that the expressions can be treated as extensions of the SNOMED CT hierarchies for the purpose of performing subsumption queries and other analytics. Utilizing the LEGO approach for modeling clinical data obtained from a nursing admission assessment provides a foundation for data exchange across disparate information systems and software applications. Clinical data exchange of computable LEGO patient information enables the development of more refined data analytics, data storage and clinical decision support.

  11. Variation in diagnostic performance among radiologists at screening CT colonography.

    PubMed

    Pooler, B Dustin; Kim, David H; Hassan, Cesare; Rinaldi, Antonio; Burnside, Elizabeth S; Pickhardt, Perry J

    2013-07-01

    To assess the variation in diagnostic performance among radiologists at screening computed tomographic (CT) colonography. In this HIPAA-compliant, institutional review board-approved study, 6866 asymptomatic adults underwent first-time CT colonographic screening at a single center between January 2005 and November 2011. Results of examinations were interpreted by one of eight board-certified abdominal radiologists (mean number of CT colonographic studies per reader, 858; range, 131-2202). Findings at CT colonography and subsequent colonoscopy were recorded, and key measures of diagnostic performance, including adenoma and advanced neoplasia detection rate, were compared among the radiologists. The overall prevalence of histopathologically confirmed advanced neoplasia was 3.6% and did not differ significantly among radiologists (range, 2.4%-4.4%; P = .067; P = .395 when one outlier was excluded). Overall, 19.5% of polyps detected at CT colonography proved to be advanced neoplasia and did not differ significantly among radiologists (range, 14.4%-23.2%; P = .223). The overall per-polyp endoscopic confirmation rate was 93.5%, ranging from 80.0% to 97.6% among radiologists (P = .585). The overall percentage of nondiagnostic CT colonographic examinations was 0.7% and was consistent among radiologists (range, 0.3%-1.1%; P = .509). Consistent performance for adenoma and advanced neoplasia detection, as well as other clinically relevant end points, were observed among radiologists at CT colonographic screening.

  12. Recurrent dermatofibrosarcoma protuberans with pulmonary metastases presenting twelve years after initial diagnosis: 18F-FDG PET/CT imaging findings.

    PubMed

    Suman, Sudhir; Sharma, Punit; Jain, Tarun Kumar; Sahoo, Manas Kumar; Bal, Chandrasekhar; Kumar, Rakesh

    2014-01-01

    Dermatofibrosarcoma protuberans is a rare cutaneous tumor that is locally aggressive and has a high rate of recurrence after surgical excision. The tumor grows slowly, typically over years. On rare occasions, metastasis to distant sites (especially the lung) or regional lymph nodes may occur. Here, we present F-FDG PET/CT imaging findings of a 52-year-old man with a local recurrence of dermatofibrosarcoma protuberans in the anterior abdominal wall with metastases to bilateral lungs.

  13. PET/CT vs. non-contrast CT alone for surveillance 1-year post lobectomy for stage I non-small-cell lung cancer

    PubMed Central

    Dane, Bari; Grechushkin, Vadim; Plank, April; Moore, William; Bilfinger, Thomas

    2013-01-01

    18F-FDG PET/CT was compared with non-contrast chest CT in monitoring for recurrence 1-year after lobectomy of stage 1 non-small-cell lung cancer (NSCLC). For surveillance after treatment with curative intent, current (April 2012) National Comprehensive Cancer network guidelines recommend chest CT with or without contrast every 6-12 months for 2 years, then non-contrast chest CT annually. PET/CT is not currently indicated for routine follow-up. One hundred patients receiving surveillance PET/CT 1-year after lobectomy for the treatment of stage 1a or 1b NSCLC were included in the study. Exclusion criteria included the presence or interval diagnosis of a second malignancy, or surgical treatment more radical than single lobectomy. The non-contrast CT obtained from the 1-year PET/CT was interpreted by an experienced chest radiologist blinded to the PET/CT for evidence of recurrence using the following findings: pulmonary nodule, pleural effusion, pleural mass, adenopathy, and extrathoracic mass. The ecision about recurrence was made solely from the non-contrast CT without PET/CT findings. This was compared with the determination made with PET/CT. The reference standard for determination of recurrence was the multi-disciplinary tumor board who had access to all imaging and clinical data. Recurrence at 1 year was documented in 16 of 90 patients. All 16 recurrences were documented with PET/CT and 9 were found with non-contrast CT. Five of the 7 recurrences missed with non-contrast CT were extrathoracic metastases. Sensitivity of CT and PET/CT for recurrence was 56.3% and 100%, respectively (p = 0.015). Specificity of CT and PET/CT for recurrence was 95.9% and 93.2%, respectively (p = 0.62). PMID:24116349

  14. Extragastrointestinal stromal tumor of the mesoappendix: CT findings and a review of the literature

    PubMed Central

    2012-01-01

    Background Gastrointestinal stromal tumors (GISTs) are nonepithelial, mesenchymal neoplasms that rarely occur in children. Case presentation We present a unique case of a GIST that developed outside the gastrointestinal tract within the mesoappendix of a 6-year old boy. Computed tomography (CT) revealed a slightly lobulated, homogeneous soft-tissue mass, with marked contrast enhancement. Conclusion This case study provides new insight into the CT appearance of extragastrointestinal stromal tumors. PMID:23039908

  15. 68Ga-PSMA-PET/CT in Patients With Biochemical Prostate Cancer Recurrence and Negative 18F-Choline-PET/CT.

    PubMed

    Bluemel, Christina; Krebs, Markus; Polat, Bülent; Linke, Fränze; Eiber, Matthias; Samnick, Samuel; Lapa, Constantin; Lassmann, Michael; Riedmiller, Hubertus; Czernin, Johannes; Rubello, Domenico; Bley, Thorsten; Kropf, Saskia; Wester, Hans-Juergen; Buck, Andreas K; Herrmann, Ken

    2016-07-01

    Investigating the value of Ga-PSMA-PET/CT in biochemically recurring prostate cancer patients with negative F-choline-PET/CT. One hundred thirty-nine consecutive patients with biochemical recurrence after curative (surgery and/or radiotherapy) therapy were offered participation in this sequential clinical imaging approach. Patients first underwent an F-choline-PET/CT. If negative, an additional Ga-PSMA-PET/CT was offered. One hundred twenty-five of 139 eligible patients were included in the study; 32 patients underwent additional Ga-PSMA-PET/CT. Patients with equivocal findings (n = 5) on F-choline-PET/CT and those who declined the additional Ga-PSMA-PET/CT (n = 9) were excluded. Images were analyzed visually for the presence of suspicious lesions. Findings on PET/CT were correlated with PSA level, PSA doubling time (dt), and PSA velocity (vel). The overall detection rates were 85.6% (107/125) for the sequential imaging approach and 74.4% (93/125) for F-choline-PET/CT alone. Ga-PSMA-PET/CT detected sites of recurrence in 43.8% (14/32) of the choline-negative patients. Detection rates of the sequential imaging approach and F-choline-PET/CT alone increased with higher serum PSA levels and PSA vel. Subgroup analysis of Ga-PSMA-PET/CT in F-choline negative patients revealed detection rates of 28.6%, 45.5%, and 71.4% for PSA levels of 0.2 or greater to less than 1 ng/mL, 1 to 2 ng/mL, and greater than 2 ng/mL, respectively. The sequential imaging approach designed to limit Ga-PSMA imaging to patients with negative choline scans resulted in high detection rates. Ga-PSMA-PET/CT identified sites of recurrent disease in 43.8% of the patients with negative F-choline PET/CT scans.

  16. Automated size-specific CT dose monitoring program: assessing variability in CT dose.

    PubMed

    Christianson, Olav; Li, Xiang; Frush, Donald; Samei, Ehsan

    2012-11-01

    The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED(adj)). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED(adj) between scanner models and across institutions. No significant difference was found between computer measurements of patient thickness and observer measurements (p = 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED(adj) that differed by up to 44% from effective dose estimates that were not adjusted by patient size

  17. Pneumoconiosis: Comparison of imaging and pathologic findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chong, S.; Lee, K.S.; Chung, M.J.

    2006-01-15

    Pneumoconiosis may be classified as either fibrotic or nonfibrotic, according to the presence or absence of fibrosis. Silicosis, coal worker pneumoconiosis, asbestosis, berylliosis, and talcosis are examples of fibrotic pneumoconiosis. Siderosis, stannosis, and baritosis are nonfibrotic forms of pneumoconiosis that result from inhalation of iron oxide, tin oxide, and barium sulfate particles, respectively. In an individual who has a history of exposure to silica or coal dust, a finding of nodular or reticulonodular lesions at chest radiography or small nodules with a perilymphatic distribution at thin-section computed tomography (CT), with or without eggshell calcifications, is suggestive of silicosis or coalmore » worker pneumoconiosis. Magnetic resonance imaging is helpful for distinguishing between progressive massive fibrosis and lung cancer. CT and histopathologic findings in asbestosis are similar to those in idiopathic pulmonary fibrosis, but the presence of asbestos bodies in histopathologic specimens is specific for the diagnosis of asbestosis. Giant cell interstitial pneumonia due to exposure to hard metals is classified as a fibrotic form of pneumoconiosis and appears on CT images as mixed ground-glass opacities and reticulation. Berylliosis simulates pulmonary sarcoidosis on CT images. CT findings in talcosis include small centrilobular and subpleural nodules or heterogeneous conglomerate masses that contain foci of high attenuation indicating talc deposition. Siderosis is nonfibrotic and is indicated by a CT finding of poorly defined centrilobular nodules or ground-glass opacities.« less

  18. Characteristic CT Findings After Percutaneous Cryoablation Treatment of Malignant Lung Nodules.

    PubMed

    Chaudhry, Ammar; Grechushkin, Vadim; Hoshmand, Mahsa; Kim, Choo Won; Pena, Andres; Huston, Brett; Chaya, Yair; Bilfinger, Thomas; Moore, William

    2015-10-01

    Assess computed tomography (CT) imaging characteristics after percutaneous cryotherapy for lung cancer.A retrospective IRB-approved analysis of 40 patients who underwent nonsurgical treatment for primary stage 1 lung cancer performed from January 2007 to March 2011 was included in this study. All procedures were performed using general anesthesia and CT guidance. Follow-up imaging with CT of the chest was obtained at 1 month, 3 months, 6 months, and 12 months postprocedure to evaluate the ablated lung nodule. Nodule surface area, density (in Hounsfield units), and presence or absence of cavitations were recorded. In addition, the degree of nodule enhancement was also recorded. Patients who were unable to obtain the aforementioned follow-up were excluded from the study.Thirty-six patients underwent percutaneous cryoablation with men to women ratio of 75% with mean age for men 74.6 and mean age for women 74.3 years of age. The average nodule surface area preablation and postcryoablation at 1-, 3-, 6-, and 12-month follow-ups were 2.99, 7.86, 3.89, 3.18 and 3.07[REPLACEMENT CHARACTER]cm, respectively. The average precontrast nodule density before cryoablation was 8.9 and average precontrast nodule density postprocedure at 1, 3, 6, and 12 months follow-ups were 8.5, -5.9, -9.4, and -3.8 HU, respectively. There is increased attenuation of lung nodules over time with an average postcontrast enhancement of 11.4, 18.5, 16.1, and 25.7 HU at the aforementioned time intervals. Cavitations occurred in the cryoablation zone in 53% (19/36) of patients. 80.6% (29/36) of the cavitations in the cryoablation zone resolved within 12 months. Four patients (11%) had recurrence of tumor at the site of cryoablation and none of the patients had satellite or distant metastasis.Our study shows that patients who underwent cryotherapy for lung nodules treatment had characteristic changes on follow-up CT including. The surface area of the nodule increases at the 1-month follow-up with

  19. Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshimatsu, Rika; Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp; Ishikawa, Masaki

    2016-06-15

    PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumormore » enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.« less

  20. Prediction value of the Canadian CT head rule and the New Orleans criteria for positive head CT scan and acute neurosurgical procedures in minor head trauma: a multicenter external validation study.

    PubMed

    Bouida, Wahid; Marghli, Soudani; Souissi, Sami; Ksibi, Hichem; Methammem, Mehdi; Haguiga, Habib; Khedher, Sonia; Boubaker, Hamdi; Beltaief, Kaouthar; Grissa, Mohamed Habib; Trimech, Mohamed Naceur; Kerkeni, Wiem; Chebili, Nawfel; Halila, Imen; Rejeb, Imen; Boukef, Riadh; Rekik, Noureddine; Bouhaja, Bechir; Letaief, Mondher; Nouira, Semir

    2013-05-01

    The New Orleans Criteria and the Canadian CT Head Rule have been developed to decrease the number of normal computed tomography (CT) results in mild head injury. We compare the performance of both decision rules for identifying patients with intracranial traumatic lesions and those who require an urgent neurosurgical intervention after mild head injury. This was an observational cohort study performed between 2008 and 2011 on patients with mild head injury who were aged 10 years or older. We collected prospectively clinical head CT scan findings and outcome. Primary outcome was need for neurosurgical intervention, defined as either death or craniotomy, or the need of intubation within 15 days of the traumatic event. Secondary outcome was the presence of traumatic lesions on head CT scan. New Orleans Criteria and Canadian CT Head Rule decision rules were compared by using sensitivity specifications and positive and negative predictive value. We enrolled 1,582 patients. Neurosurgical intervention was performed in 34 patients (2.1%) and positive CT findings were demonstrated in 218 patients (13.8%). Sensitivity and specificity for need for neurosurgical intervention were 100% (95% confidence interval [CI] 90% to 100%) and 60% (95% CI 44% to 76%) for the Canadian CT Head Rule and 82% (95% CI 69% to 95%) and 26% (95% CI 24% to 28%) for the New Orleans Criteria. Negative predictive values for the above-mentioned clinical decision rules were 100% and 99% and positive values were 5% and 2%, respectively, for the Canadian CT Head Rule and New Orleans Criteria. Sensitivity and specificity for clinical significant head CT findings were 95% (95% CI 92% to 98%) and 65% (95% CI 62% to 68%) for the Canadian CT Head Rule and 86% (95% CI 81% to 91%) and 28% (95% CI 26% to 30%) for the New Orleans Criteria. A similar trend of results was found in the subgroup of patients with a Glasgow Coma Scale score of 15. For patients with mild head injury, the Canadian CT Head Rule had higher

  1. CT, MRI, and 18F-FDG PET/CT findings of malignant peripheral nerve sheath tumor of the head and neck.

    PubMed

    Kim, Ha Youn; Hwang, Ji Young; Kim, Hyung-Jin; Kim, Yi Kyung; Cha, Jihoon; Park, Gyeong Min; Kim, Sung Tae

    2017-10-01

    Background Malignant peripheral nerve sheath tumor (MPNST) is a highly malignant tumor and rarely occurs in the head and neck. Purpose To describe the imaging features of MPNST of the head and neck. Material and Methods We retrospectively analyzed computed tomography (CT; n = 14), magnetic resonance imaging (MRI; n = 16), and 18 F-FDG PET/CT (n = 5) imaging features of 18 MPNSTs of the head and neck in 17 patients. Special attention was paid to determine the nerve of origin from which the tumor might have arisen. Results All lesions were well-defined (n = 3) or ill-defined (n = 15) masses (mean, 6.1 cm). Lesions were at various locations but most commonly the neck (n = 8), followed by the intracranial cavity (n = 3), paranasal sinus (n = 2), and orbit (n = 2). The nerve of origin was inferred for 11 lesions: seven in the neck, two in the orbit, one in the cerebellopontine angle, and one on the parietal scalp. Attenuation, signal intensity, and enhancement pattern of the lesions on CT and MRI were non-specific. Necrosis/hemorrhage/cystic change within the lesion was considered to be present on images in 13 and bone change in nine. On 18 F-FDG PET/CT images, all five lesions demonstrated various hypermetabolic foci with maximum standard uptake value (SUV max ) from 3.2 to 14.6 (mean, 7.16 ± 4.57). Conclusion MPNSTs can arise from various locations in the head and neck. Though non-specific, a mass with an ill-defined margin along the presumed course of the cranial nerves may aid the diagnosis of MPSNT in the head and neck.

  2. New astrometry and photometry for the companion candidates of CT Cha

    NASA Astrophysics Data System (ADS)

    Schmidt, Tobias O. B.; Neuhäuser, Ralph; Mugrauer, Markus; Bedalov, Ana; Vogt, Nikolaus

    2009-02-01

    In our ongoing search for close and faint companions around T Tauri stars in the Chamaeleon star-forming region, we recently (Schmidt et al. 2008 b) presented direct observations and integral field spectroscopy of a new common proper motion companion to the young T-Tauri star and Chamaeleon member CT Cha and discussed its properties in comparison to other young, low-mass objects and to synthetic model spectra from different origins. We now obtained for the first time direct H-Band observations of the companion CT Cha b and of another faint companion candidate (cc2) approximately 1.9 arcsec northeast of CT Cha using the Adaptive Optics (AO) instrument Naos-Conica (NACO) at the Very Large Telescope (VLT) of the European Southern Observatory (ESO) in February 2008. From these data we can now exclude by 4.4 & 4.8 σ that CT Cha b is a non-moving background object and find cc2 to be most likely a background star of spectral type <=K4 with a proper motion of μα cos δ = -8.5+/-5.7 mas/yr and μδ = 12.0+/-5.6 mas/yr, not consistent with being a member of the Cha I star-forming region.

  3. Malignant external otitis: CT evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curtin, H.D.; Wolfe, P.; May, M.

    1982-11-01

    Malignant external otitis is an aggressive infection caused by Pseudomonas aeruginosa that most often occurs in elderly diabetics. Malignant external otitis often spreads inferiorly from the external canal to involve the subtemporal area and progresses medially towards the petrous apex leading to multiple cranial nerve palsies. The computed tomographic (CT) findings in malignant external otitis include obliteration of the normal fat planes in the subtemporal area as well as patchy destruction of the bony cortex of the mastoid. The point of exit of the various cranial nerves can be identified on CT scans, and the extent of the inflammatory massmore » correlates well with the clinical findings. Four cases of malignant external otitis are presented. In each case CT provided a good demonstration of involvement of the soft tissues at the base of the skull.« less

  4. The clinical significance of perivalvular pannus in prosthetic mitral valves: Can cardiac CT be helpful?

    PubMed

    Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook

    2017-12-15

    The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (P<0.05). Prosthetic MV pannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Effect of emergency department CT on neuroimaging case volume and positive scan rates.

    PubMed

    Oguz, Kader Karli; Yousem, David M; Deluca, Tom; Herskovits, Edward H; Beauchamp, Norman J

    2002-09-01

    The authors performed this study to determine the effect a computed tomographic (CT) scanner in the emergency department (ED) has on neuroimaging case volume and positive scan rates. The total numbers of ED visits and neuroradiology CT scans requested from the ED were recorded for 1998 and 2000, the years before and after the installation of a CT unit in the ED. For each examination type (brain, face, cervical spine), studies were graded for major findings (those that affected patient care), minor findings, and normal findings. The CT utilization rates and positive study rates were compared for each type of study performed for both years. There was a statistically significant increase in the utilization rate after installation of the CT unit (P < .001). The fractions of studies with major findings, minor findings, and normal findings changed significantly after installation of the CT unit for facial examinations (P = .002) but not for brain (P = .12) or cervical spine (P = .24) examinations. In all types of studies, the percentage of normal examinations increased. In toto, there was a significant decrease in the positive scan rate after installation of the CT scanner (P = .004). After installation of a CT scanner in the ED, there was increased utilization and a decreased rate of positive neuroradiologic examinations, the latter primarily due to lower positive rates for facial CT scans.

  6. Thin-section computed tomography findings in 104 immunocompetent patients with adenovirus pneumonia.

    PubMed

    Park, Chan Kue; Kwon, Hoon; Park, Ji Young

    2017-08-01

    Background To date, there has been no computed tomography (CT) evaluation of adenovirus pneumonia in a large number of immunocompetent patients. Purpose To describe the thin-section CT findings of immunocompetent patients with adenovirus pneumonia. Material and Methods We prospectively enrolled 104 patients with adenovirus pneumonia from a military hospital. CT scans of each patient were retrospectively and independently assessed by two radiologists for the presence of abnormalities, laterality and zonal predominance of the parenchymal abnormalities, and dominant imaging patterns and their anatomic distributions. Results CT findings included consolidation (n = 92), ground-glass opacity (GGO; n = 82), septal thickening (n = 34), nodules (n = 46), bronchial wall thickening (n = 32), pleural effusion (n = 16), and lymphadenopathy (n = 3). Eighty-four patients (81%) exhibited unilateral parenchymal abnormalities and 57 (57%) exhibited lower lung zone abnormalities. The most frequently dominant CT pattern was consolidation with surrounding GGO (n = 50), with subpleural (70%) and peribronchovascular (94%) distributions. Consolidation-the second-most common pattern (n = 33)-also exhibited subpleural (79%) and peribronchovascular (97%) distributions. The dominant nodule pattern (n = 14) exhibited mixed (64%) and peribronchovascular (100%) distributions. A dominant GGO pattern was only observed in four patients; none had central distribution. Conclusion Although the manifestations of adenovirus pneumonia on CT are varied, we found the most frequent pattern was consolidation with or without surrounding GGO, with subpleural and peribronchovascular distributions. Parenchymal abnormalities were predominantly unilateral and located in the lower lung zone. If dominant consolidation findings are present in immunocompetent patients during the early stages, adenovirus pneumonia should be considered.

  7. FDG PET/CT in bone sarcoidosis.

    PubMed

    Grozdic Milojevic, Isidora; Sobic-Saranovic, Dragana; Videnovic-Ivanov, Jelica; Saranovic, Djordjije; Odalovic, Strahinja; Artiko, Vera

    2016-03-29

    Bone sarcoidosis is rare manifestation of disease usually accompanied with pulmonary involvement. Until today, exact prevalence of bone sarcoidosis is not known, since reported prevalence varies widely depending on the studied population and the used diagnostic techniques. To determine the prevalence of bone involvement and distribution pattern in active chronic sarcoidosis by using FDG PET/CT. Between January 2010 and December 2011, 98 patients with chronic sarcoidosis and presence of prolonged symptoms or other findings suggestive of active disease were referred to FDG PET/CT examination. Active disease was found in 82 patients, and they all were screened for presence of bone sarcoidosis on FDG PET/CT. All patients also underwent MDCT and assessment of serum ACE level. Bone sarcoidosis was present in 18/82 patients with active sarcoidosis. FDG uptake in bones was focal in 8 (44.4%), diffuse in 6 (33.3%) and both diffuse and focal in 4 (22.2%) patients. CT indicated bone abnormalities only in 5% patients. Osseous involvement was present in: pelvis (61.1%), vertebrae (44.4%), ribs (27.8%) and bone marrow (16.7%). Some patients had two or more locations of disease. Follow-up FDG PET/CT showed normal findings in two patients, same localization of active disease in four patients and progression of disease in one. In patients with active chronic sarcoidosis 22% of patients had osseous abnormalities on FDG PET/CT that mostly were not detected on CT.

  8. FDG PET/CT Findings in Primary Diffuse Large B-cell Lymphoma, Leg Type.

    PubMed

    Ni, Chiayi; Lewis, Michael; Berenji, Gholam

    2016-01-01

    A 64-year-old man presented with complaints of worsening left foot pain and swelling. MRI showed a soft tissue mass overlying the dorsolateral aspect of the left foot. Following a 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), the left foot mass was biopsied and pathology indicated a diagnosis of primary diffuse large B-cell lymphoma, leg type (PDLBCL, LT). Review of the PET/CT images demonstrated hypermetabolic activity associated with the left foot mass, multiple subcutaneous nodules/nodes, sclerotic osseous lesions in the lower extremities, and left external iliac/left inguinal lymphadenopathy. At the moment, the patient is undergoing chemotherapy.

  9. Influence of radiation therapy on the lung-tissue in breast cancer patients: CT-assessed density changes and associated symptoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rotstein, S.; Lax, I.; Svane, G.

    1990-01-01

    The relative electron density of lung tissue was measured from computer tomography (CT) slices in 33 breast cancer patients treated by various techniques of adjuvant radiotherapy. The measurements were made before radiotherapy, 3 months and 9 months after completion of radiation therapy. The changes in lung densities at 3 months and 9 months were compared to radiation induced radiological (CT) findings. In addition, subjective symptoms such as cough and dyspnoea were assessed before and after radiotherapy. It was observed that the mean of the relative electron density of lung tissue varied from 0.25 when the whole lung was considered tomore » 0.17 when only the anterior lateral quarter of the lung was taken into account. In patients with positive radiological (CT) findings the mean lung density of the anterior lateral quarter increased 2.1 times 3 months after radiotherapy and was still increased 1.6 times 6 months later. For those patients without findings, in the CT pictures the corresponding values were 1.2 and 1.1, respectively. The standard deviation of the pixel values within the anterior lateral quarter of the lung increased 3.8 times and 3.2 times at 3 months and 9 months, respectively, in the former group, as opposed to 1.2 and 1.1 in the latter group. Thirteen patients had an increase in either cough or dyspnoea as observed 3 months after completion of radiotherapy. In eleven patients these symptoms persisted 6 months later. No significant correlation was found between radiological findings and subjective symptoms. However, when three different treatment techniques were compared among 29 patients the highest rate of radiological findings was observed in patients in which the largest lung volumes received the target dose. A tendency towards an increased rate of subjective symptoms was also found in this group.« less

  10. Semantic similarity-based alignment between clinical archetypes and SNOMED CT: an application to observations.

    PubMed

    Meizoso García, María; Iglesias Allones, José Luis; Martínez Hernández, Diego; Taboada Iglesias, María Jesús

    2012-08-01

    One of the main challenges of eHealth is semantic interoperability of health systems. But, this will only be possible if the capture, representation and access of patient data is standardized. Clinical data models, such as OpenEHR Archetypes, define data structures that are agreed by experts to ensure the accuracy of health information. In addition, they provide an option to normalize clinical data by means of binding terms used in the model definition to standard medical vocabularies. Nevertheless, the effort needed to establish the association between archetype terms and standard terminology concepts is considerable. Therefore, the purpose of this study is to provide an automated approach to bind OpenEHR archetypes terms to the external terminology SNOMED CT, with the capability to do it at a semantic level. This research uses lexical techniques and external terminological tools in combination with context-based techniques, which use information about structural and semantic proximity to identify similarities between terms and so, to find alignments between them. The proposed approach exploits both the structural context of archetypes and the terminology context, in which concepts are logically defined through the relationships (hierarchical and definitional) to other concepts. A set of 25 OBSERVATION archetypes with 477 bound terms was used to test the method. Of these, 342 terms (74.6%) were linked with 96.1% precision, 71.7% recall and 1.23 SNOMED CT concepts on average for each mapping. It has been detected that about one third of the archetype clinical information is grouped logically. Context-based techniques take advantage of this to increase the recall and to validate a 30.4% of the bindings produced by lexical techniques. This research shows that it is possible to automatically map archetype terms to a standard terminology with a high precision and recall, with the help of appropriate contextual and semantic information of both models. Moreover, the

  11. Utility of CT in the diagnosis and management of small-bowel obstruction in children.

    PubMed

    Wang, Qiuyan; Chavhan, Govind B; Babyn, Paul S; Tomlinson, George; Langer, Jacob C

    2012-12-01

    CT is often used in the diagnosis and management of small-bowel obstruction in children. To determine sensitivity of CT in delineating presence, site and cause of small-bowel obstruction in children. We retrospectively reviewed the CT scans of 47 children with surgically proven small-bowel obstruction. We noted any findings of obstruction and the site and cause of obstruction. Presence, absence or equivocal findings of bowel obstruction on abdominal radiographs performed prior to CT were also noted. We reviewed patient charts for clinical details and surgical findings, including bowel resection. Statistical analysis was performed using Fisher exact test to determine which CT findings might predict bowel resection. CT correctly diagnosed small-bowel obstruction in 43/47 (91.5%) cases. CT correctly indicated site of obstruction in 37/47 (78.7%) cases and cause of obstruction in 32/47 (68.1%) cases. Small-bowel feces sign was significantly associated with bowel resection at surgery (P = 0.0091). No other CT finding was predictive of bowel resection. Out of 41 children who had abdominal radiographs before CT, 29 (70.7%) showed unequivocal obstruction, six (14.6%) showed equivocal findings and six (14.6%) were unremarkable. CT is highly sensitive in diagnosing small-bowel obstruction in children and is helpful in determining the presence of small-bowel obstruction in many clinically suspected cases with equivocal or normal plain radiographs. CT also helps to determine the site and cause of the obstruction with good sensitivity.

  12. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    PubMed

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  13. Lung cancer mimicking lung abscess formation on CT images.

    PubMed

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Male, 64 FINAL DIAGNOSIS: Lung pleomorphic carcinoma Symptoms: Cough • fever - Clinical Procedure: - Specialty: Oncology. Unusual clinical course. The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resembled a lung abscess on CT. We herein describe the case of 64-year-old male who was diagnosed with lung cancer using surgery. In this case, it was quite difficult to distinguish between the lung cancer and a lung abscess on CT images, and a lung abscess was initially suspected due to symptoms, such as fever and coughing, contrast-enhanced CT image findings showing a ring-enhancing mass in the right upper lobe and the patient's laboratory test results. However, a pathological diagnosis of lung cancer was confirmed according to the results of a rapid frozen section biopsy of the lesion. This case suggests that physicians should not suspect both a lung abscesses and malignancy in cases involving masses presenting as ring-enhancing lesions on contrast-enhanced CT.

  14. Characteristic CT Findings After Percutaneous Cryoablation Treatment of Malignant Lung Nodules

    PubMed Central

    Chaudhry, Ammar; Grechushkin, Vadim; Hoshmand, Mahsa; Kim, Choo Won; Pena, Andres; Huston, Brett; Chaya, Yair; Bilfinger, Thomas; Moore, William

    2015-01-01

    Abstract Assess computed tomography (CT) imaging characteristics after percutaneous cryotherapy for lung cancer. A retrospective IRB-approved analysis of 40 patients who underwent nonsurgical treatment for primary stage 1 lung cancer performed from January 2007 to March 2011 was included in this study. All procedures were performed using general anesthesia and CT guidance. Follow-up imaging with CT of the chest was obtained at 1 month, 3 months, 6 months, and 12 months postprocedure to evaluate the ablated lung nodule. Nodule surface area, density (in Hounsfield units), and presence or absence of cavitations were recorded. In addition, the degree of nodule enhancement was also recorded. Patients who were unable to obtain the aforementioned follow-up were excluded from the study. Thirty-six patients underwent percutaneous cryoablation with men to women ratio of 75% with mean age for men 74.6 and mean age for women 74.3 years of age. The average nodule surface area preablation and postcryoablation at 1-, 3-, 6-, and 12-month follow-ups were 2.99, 7.86, 3.89, 3.18 and 3.07�cm2, respectively. The average precontrast nodule density before cryoablation was 8.9 and average precontrast nodule density postprocedure at 1, 3, 6, and 12 months follow-ups were 8.5, −5.9, −9.4, and −3.8 HU, respectively. There is increased attenuation of lung nodules over time with an average postcontrast enhancement of 11.4, 18.5, 16.1, and 25.7 HU at the aforementioned time intervals. Cavitations occurred in the cryoablation zone in 53% (19/36) of patients. 80.6% (29/36) of the cavitations in the cryoablation zone resolved within 12 months. Four patients (11%) had recurrence of tumor at the site of cryoablation and none of the patients had satellite or distant metastasis. Our study shows that patients who underwent cryotherapy for lung nodules treatment had characteristic changes on follow-up CT including. The surface area of the nodule increases at the 1-month follow-up with

  15. Variation in Diagnostic Performance among Radiologists at Screening CT Colonography

    PubMed Central

    Pooler, B. Dustin; Kim, David H.; Hassan, Cesare; Rinaldi, Antonio; Burnside, Elizabeth S.

    2013-01-01

    Purpose: To assess the variation in diagnostic performance among radiologists at screening computed tomographic (CT) colonography. Materials and Methods: In this HIPAA-compliant, institutional review board–approved study, 6866 asymptomatic adults underwent first-time CT colonographic screening at a single center between January 2005 and November 2011. Results of examinations were interpreted by one of eight board-certified abdominal radiologists (mean number of CT colonographic studies per reader, 858; range, 131–2202). Findings at CT colonography and subsequent colonoscopy were recorded, and key measures of diagnostic performance, including adenoma and advanced neoplasia detection rate, were compared among the radiologists. Results: The overall prevalence of histopathologically confirmed advanced neoplasia was 3.6% and did not differ significantly among radiologists (range, 2.4%–4.4%; P = .067; P = .395 when one outlier was excluded). Overall, 19.5% of polyps detected at CT colonography proved to be advanced neoplasia and did not differ significantly among radiologists (range, 14.4%–23.2%; P = .223). The overall per-polyp endoscopic confirmation rate was 93.5%, ranging from 80.0% to 97.6% among radiologists (P = .585). The overall percentage of nondiagnostic CT colonographic examinations was 0.7% and was consistent among radiologists (range, 0.3%–1.1%; P = .509). Conclusion: Consistent performance for adenoma and advanced neoplasia detection, as well as other clinically relevant end points, were observed among radiologists at CT colonographic screening. © RSNA, 2013 PMID:23449954

  16. Journal Club: Head CT scans in the emergency department for syncope and dizziness.

    PubMed

    Mitsunaga, Myles M; Yoon, Hyo-Chun

    2015-01-01

    The purpose of this study was to determine the yield of acutely abnormal findings on head CT scans in patients presenting to the emergency department with dizziness, near-syncope, or syncope and to determine the clinical factors that potentially predicted acutely abnormal head CT findings and hospital admission. We retrospectively reviewed the electronic medical records of all patients presenting to an HMO emergency department between July 1, 2012, and December 31, 2012, who underwent head CT for a primary complaint of dizziness, syncope, or near-syncope. The primary outcomes were head CT scans with acutely abnormal findings and hospital admission. Binary logistic regression was used to assess the association between clinical variables and acute head CT findings and between clinical variables and hospital admission. Of the 253 patients who presented with dizziness, 7.1% had head CT scans with acutely abnormal findings, and 18.6% were admitted. Of the 236 patients who presented with syncope or near-syncope, 6.4% had head CT scans with acutely abnormal findings, and 39.8% were admitted. The following three clinical factors were found to be significantly correlated with acutely abnormal head CT findings: a focal neurologic deficit (p = 0.003), age greater than 60 years (p = 0.011), and acute head trauma (p = 0.026). Our results suggest that most patients presenting with syncope or dizziness to the emergency department may not benefit from head CT unless they are older, have a focal neurologic deficit, or have a history of recent head trauma.

  17. Orbit CT scan

    MedlinePlus

    ... You will be asked to remove jewelry and wear a hospital gown during the study. If you weigh more than 300 pounds (135 kilograms), find out if the CT machine has a weight limit. Too much weight can ...

  18. Quantification of pleural effusion on CT by simple measurement.

    PubMed

    Hazlinger, Martin; Ctvrtlik, Filip; Langova, Katerina; Herman, Miroslav

    2014-01-01

    To find the simplest method for quantifying pleural effusion volume from CT scans. Seventy pleural effusions found on chest CT examination in 50 consecutive adult patients with the presence of free pleural effusion were included. The volume of pleural effusion was calculated from a three-dimensional reconstruction of CT scans. Planar measurements were made on CT scans and their two-dimensional reconstructions in the sagittal plane and at three levels on transversal scans. Individual planar measurements were statistically compared with the detected volume of pleural effusion. Regression equations, averaged absolute difference between observed and predicted values and determination coefficients were found for all measurements and their combinations. A tabular expression of the best single planar measurement was created. The most accurate correlation between the volume and a single planar measurement was found in the dimension measured perpendicular to the parietal pleura on transversal scan with the greatest depth of effusion. Conversion of this measurement to the appropriate volume is possible by regression equation: Volume = 0.365 × b(3) - 4.529 × b(2) + 159.723 × b - 88.377. We devised a simple method of conversion of a single planar measurement on CT scan to the volume of pleural effusion. The tabular expression of our equation can be easily and effectively used in routine practice.

  19. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    PubMed

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  20. 68Ga-PSMA-PET/CT in Patients With Biochemical Prostate Cancer Recurrence and Negative 18F-Choline-PET/CT

    PubMed Central

    Bluemel, Christina; Krebs, Markus; Polat, Bülent; Linke, Fränze; Eiber, Matthias; Samnick, Samuel; Lapa, Constantin; Lassmann, Michael; Riedmiller, Hubertus; Czernin, Johannes; Rubello, Domenico; Bley, Thorsten; Kropf, Saskia; Wester, Hans-Juergen; Buck, Andreas K.; Herrmann, Ken

    2016-01-01

    Purpose Investigating the value of 68Ga-PSMA-PET/CT in biochemically recurring prostate cancer patients with negative 18F-choline-PET/CT. Patients and Methods One hundred thirty-nine consecutive patients with biochemical recurrence after curative (surgery and/or radiotherapy) therapy were offered participation in this sequential clinical imaging approach. Patients first underwent an 18F-choline-PET/CT. If negative, an additional 68Ga-PSMA-PET/CTwas offered. One hundred twenty-five of 139 eligible patients were included in the study; 32 patients underwent additional 68Ga-PSMA-PET/CT. Patients with equivocal findings (n = 5) on 18F-choline-PET/CT and those who declined the additional 68Ga-PSMA-PET/CT (n = 9) were excluded. Images were analyzed visually for the presence of suspicious lesions. Findings on PET/CT were correlated with PSA level, PSA doubling time (dt), and PSA velocity (vel). Results The overall detection rates were 85.6% (107/125) for the sequential imaging approach and 74.4% (93/125) for 18F-choline-PET/CT alone. 68Ga-PSMA-PET/CT detected sites of recurrence in 43.8% (14/32) of the choline-negative patients. Detection rates of the sequential imaging approach and 18F-choline-PET/CT alone increased with higher serum PSA levels and PSA vel. Subgroup analysis of 68Ga-PSMA-PET/CT in 18F-choline negative patients revealed detection rates of 28.6%, 45.5%, and 71.4% for PSA levels of 0.2 or greater to less than 1 ng/mL, 1 to 2 ng/mL, and greater than 2 ng/mL, respectively. Conclusions The sequential imaging approach designed to limit 68Ga-PSMA imaging to patients with negative choline scans resulted in high detection rates. 68Ga-PSMA-PET/CT identified sites of recurrent disease in 43.8% of the patients with negative 18F-choline PET/CT scans. PMID:26975008

  1. Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang Xiangyang; Yang Yi; Tang Shaojie

    and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.« less

  2. Inter-observer variability in diagnosing radiological features of aneurysmal subarachnoid hemorrhage; a preliminary single centre study comparing observers from different specialties and levels of training.

    PubMed

    Siddiqui, Usman T; Khan, Anjum F; Shamim, Muhammad Shahzad; Hamid, Rana Shoaib; Alam, Muhammad Mehboob; Emaduddin, Muhammad

    2014-01-01

    A noncontrast computed tomography (CT) scan remains the initial radiological investigation of choice for a patient with suspected aneurysmal subarachnoid hemorrhage (aSAH). This initial scan may be used to derive key information about the underlying aneurysm which may aid in further management. The interpretation, however, is subject to the skill and experience of the interpreting individual. The authors here evaluate the interpretation of such CT scans by different individuals at different levels of training, and in two different specialties (Radiology and Neurosurgery). Initial nonontrast CT scan of 35 patients with aSAH was evaluated independently by four different observers. The observers selected for the study included two from Radiology and two from Neurosurgery at different levels of training; a resident currently in mid training and a resident who had recently graduated from training of each specialty. Measured variables included interpreter's suspicion of presence of subarachnoid blood, side of the subarachnoid hemorrhage, location of the aneurysm, the aneurysm's proximity to vessel bifurcation, number of aneurysm(s), contour of aneurysm(s), presence of intraventricular hemorrhage (IVH), intracerebral hemorrhage (ICH), infarction, hydrocephalus and midline shift. To determine the inter-observer variability (IOV), weighted kappa values were calculated. There was moderate agreement on most of the CT scan findings among all observers. Substantial agreement was found amongst all observers for hydrocephalus, IVH, and ICH. Lowest agreement rates were seen in the location of aneurysm being supra or infra tentorial. There were, however, some noteworthy exceptions. There was substantial to almost perfect agreement between the radiology graduate and radiology resident on most CT findings. The lowest agreement was found between the neurosurgery graduate and the radiology graduate. Our study suggests that although agreements were seen in the interpretation of some of

  3. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    PubMed

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  4. Capillary Hemangioma of Thoracic Spinal Cord: PET/CT and MR Findings.

    PubMed

    Shen, Guohua; Su, Minggang; Zhao, Junyi; Liu, Bin; Kuang, Anren

    2017-05-01

    Capillary hemangiomas are frequently encountered superficially in the cutaneous, subcutaneous, or mucosal tissues during the childhood and early adulthood, but the occurrence of spinal intradural capillary hemangioma is relatively rare. Herein, we report a case with capillary hemangioma of the thoracic spine. MR and PET/CT features of this lesion are presented, and awareness of this entity may help differentiate it from other spinal intradural tumors.

  5. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    PubMed

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  6. Regional deep hyperthermia: impact of observer variability in CT-based manual tissue segmentation on simulated temperature distribution

    NASA Astrophysics Data System (ADS)

    Aklan, Bassim; Hartmann, Josefin; Zink, Diana; Siavooshhaghighi, Hadi; Merten, Ricarda; Putz, Florian; Ott, Oliver; Fietkau, Rainer; Bert, Christoph

    2017-06-01

    The aim of this study was to systematically investigate the influence of the inter- and intra-observer segmentation variation of tumors and organs at risk on the simulated temperature coverage of the target. CT scans of six patients with tumors in the pelvic region acquired for radiotherapy treatment planning were used for hyperthermia treatment planning. To study the effect of inter-observer variation, three observers manually segmented in the CT images of each patient the following structures: fat, muscle, bone and the bladder. The gross tumor volumes (GTV) were contoured by three radiation oncology residents and used as the hyperthermia target volumes. For intra-observer variation, one of the observers of each group contoured the structures of each patient three times with a time span of one week between the segmentations. Moreover, the impact of segmentation variations in organs at risk (OARs) between the three inter-observers was investigated on simulated temperature distributions using only one GTV. The spatial overlap between individual segmentations was assessed by the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Additionally, the temperatures T90/T10 delivered to 90%/10% of the GTV, respectively, were assessed for each observer combination. The results of the segmentation similarity evaluation showed that the DSC of the inter-observer variation of fat, muscle, the bladder, bone and the target was 0.68  ±  0.12, 0.88  ±  0.05, 0.73  ±  0.14, 0.91  ±  0.04 and 0.64  ±  0.11, respectively. Similar results were found for the intra-observer variation. The MSD results were similar to the DSCs for both observer variations. A statistically significant difference (p  <  0.05) was found for T90 and T10 in the predicted target temperature due to the observer variability. The conclusion is that intra- and inter-observer variations have a significant impact on the temperature coverage of the

  7. CT volumetry of the skeletal tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brindle, James M.; Alexandre Trindade, A.; Pichardo, Jose C.

    2006-10-15

    Computed tomography (CT) is an important and widely used modality in the diagnosis and treatment of various cancers. In the field of molecular radiotherapy, the use of spongiosa volume (combined tissues of the bone marrow and bone trabeculae) has been suggested as a means to improve the patient-specificity of bone marrow dose estimates. The noninvasive estimation of an organ volume comes with some degree of error or variation from the true organ volume. The present study explores the ability to obtain estimates of spongiosa volume or its surrogate via manual image segmentation. The variation among different segmentation raters was exploredmore » and found not to be statistically significant (p value >0.05). Accuracy was assessed by having several raters manually segment a polyvinyl chloride (PVC) pipe with known volumes. Segmentation of the outer region of the PVC pipe resulted in mean percent errors as great as 15% while segmentation of the pipe's inner region resulted in mean percent errors within {approx}5%. Differences between volumes estimated with the high-resolution CT data set (typical of ex vivo skeletal scans) and the low-resolution CT data set (typical of in vivo skeletal scans) were also explored using both patient CT images and a PVC pipe phantom. While a statistically significant difference (p value <0.002) between the high-resolution and low-resolution data sets was observed with excised femoral heads obtained following total hip arthroplasty, the mean difference between high-resolution and low-resolution data sets was found to be only 1.24 and 2.18 cm{sup 3} for spongiosa and cortical bone, respectively. With respect to differences observed with the PVC pipe, the variation between the high-resolution and low-resolution mean percent errors was a high as {approx}20% for the outer region volume estimates and only as high as {approx}6% for the inner region volume estimates. The findings from this study suggest that manual segmentation is a reasonably

  8. Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT.

    PubMed

    Shi, Bowen; Lin, Huimin; Zhang, Miao; Lu, Wei; Qu, Ying; Zhang, Huan

    2018-01-22

    Gastric cancer remains fourth in cancer incidence worldwide with a five-year survival of only 20%-30%. Peritoneal metastasis is the most frequent type of metastasis that accompanies unresectable gastric cancer and is a definitive determinant of prognosis. Preventing and controlling the development of peritoneal metastasis could play a role in helping to prolong the survival of gastric cancer patients. A non-invasive and efficient imaging technique will help us to identify the invasion and metastasis process of peritoneal metastasis and to monitor the changes in tumor nodules in response to treatments. This will enable us to obtain an accurate description of the development process and molecular mechanisms of gastric cancer. We have recently described experiment using dual energy CT (DECT) and positron emission tomography/computed tomography (PET/CT) platforms for the detection and monitoring of gastric tumor metastasis in nude mice models. We have shown that weekly continuous monitoring with DECT and PET/CT can identify dynamic changes in peritoneal metastasis. The sFRP1-overexpression in gastric cancer mice models showed positive radiological performance, a higher FDG uptake and increasing enhancement, and the SUVmax (standardized uptake value) of nodules demonstrated an obvious alteration trend in response to targeted therapy of TGF-β1 inhibitor. In this article, we described the detailed non-invasive imaging procedures to conduct more complex research on gastric cancer peritoneal metastasis using animal models and provided representative imaging results. The use of non-invasive imaging techniques should enable us to better understand the mechanisms of tumorigenesis, monitor tumor growth, and evaluate the effect of therapeutic interventions for gastric cancer.

  9. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    PubMed

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p < 0.05). All three sealers presented less void volume in the apical third; however, higher void volumes were observed in the apical and coronal thirds in AH Plus using micro-CT (p < 0.05), while nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p < 0.05). Bioactive sealers showed higher root filling rate, lower incidence rate of voids, void fraction and void volume than AH Plus under nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  10. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christianson, Olav; Li Xiang; Frush, Donald

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CTmore » imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  11. Computed tomography findings associated with bacteremia in adult patients with a urinary tract infection.

    PubMed

    Yu, T Y; Kim, H R; Hwang, K E; Lee, J-M; Cho, J H; Lee, J H

    2016-11-01

    The use of computed tomography (CT) in the diagnosis of urinary tract infection (UTI) has rapidly increased recently at acute stage, but the CT findings associated with bacteremia in UTI patients are unknown. 189 UTI patients were enrolled who underwent a CT scan within 24 h after hospital admission. We classified CT findings into eight types: a focal or multifocal wedge-shaped area of hypoperfusion, enlarged kidneys, perinephric fat stranding, ureteritis or pyelitis, complicated renal cyst, renal papillary necrosis, hydronephrosis, and renal and perirenal abscess. A retrospective analysis was conducted to evaluate the CT findings associated with bacteremia. The mean age of these patients was 60 ± 17.2 years, and 93.1 % were women. Concurrent bacteremia was noted in 40.2 % of the patients. Abnormal CT findings were noted in 96.3 % of the patients and 62.4 % had two or more abnormal findings. The most frequent abnormal CT finding was a focal or multifocal wedge-shaped area of hypoperfusion (77.2 %), followed by perinephric fat stranding (29.1 %). Perinephric fat stranding, hydronephrosis, and the presence of two or more abnormal CT findings were significantly associated with bacteremia in patients with community-acquired UTI. In the multivariate logistic regression analysis, age [odds ratio (OR) 1.03; 95 % confidence interval (CI) 1.009-1.062], two or more abnormal CT findings (OR 3.163; 95 % CI 1.334-7.498), and hydronephrosis (OR 13.160; 95 % CI 1.048-165.282) were significantly associated with bacteremia. Physicians should be aware that appropriate early management is necessary to prevent fatality in patients with these CT findings.

  12. Extravasation of contrast medium during CT examination: an observational case-control study.

    PubMed

    Alami, Zayneb; Nasri, Siham; Ahid, Samir; Kacem, Hanane Hadj

    2015-01-01

    Extravasation is an adverse reaction to intravenous injection of contrast medium (CM) during CT examination. The objectives of this study are to determine the frequency, management and outcomes of extravasations and to assess risk factors for extravasation. Every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to participate in the study. Data collected in the form included patients' age, sex, comorbidities, symptoms, CM used, injection mode, site and rate, extravasated volume, location of extravasation, severity of injury, treatment and patient outcome. Each case was matched with 4 controls of the same age ± 5 years and the same gender when possible. Extravasation occurred in 18 (7 women, 11 men) out of 2,000 injections of CM (0.9%) with a median age of 53 (10-78) years. Automated injection was performed in all cases with a mean rate of 1.7 ml/s. Large extravasated volumes (≥50 ml) were more observed in patients undergoing CT angiography (28.6% vs. 6.6%, although not significant P=0.112). Multivariate analysis revealed a significant association between patients with cardiac diseases and extravasation (OR: 7.3, 95% CI (1.09-49.05), P=0.04) whereas the injection rate is a protective factor from extravasation (P=0.002). Extravasation of CM results in mild to moderate adverse effects in all cases. Our study suggests that patients with cardiac disease are more predisposed to contrast extravasation than others. Further and larger studies are needed to confirm this trend.

  13. Extravasation of contrast medium during CT examination: an observational case-control study

    PubMed Central

    Alami, Zayneb; Nasri, Siham; Ahid, Samir; Kacem, Hanane Hadj

    2015-01-01

    Introduction Extravasation is an adverse reaction to intravenous injection of contrast medium (CM) during CT examination. The objectives of this study are to determine the frequency, management and outcomes of extravasations and to assess risk factors for extravasation. Methods Every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to participate in the study. Data collected in the form included patients’ age, sex, comorbidities, symptoms, CM used, injection mode, site and rate, extravasated volume, location of extravasation, severity of injury, treatment and patient outcome. Each case was matched with 4 controls of the same age ± 5 years and the same gender when possible. Results Extravasation occurred in 18 (7 women, 11 men) out of 2,000 injections of CM (0.9%) with a median age of 53 (10-78) years. Automated injection was performed in all cases with a mean rate of 1.7ml/s. Large extravasated volumes (≥ 50ml) were more observed in patients undergoing CT angiography (28.6% vs. 6.6%, although not significant P=0.112). Multivariate analysis revealed a significant association between patients with cardiac diseases and extravasation (OR: 7.3, 95% CI (1.09-49.05), P=0.04) whereas the injection rate is a protective factor from extravasation (P=0.002). Conclusion Extravasation of CM results in mild to moderate adverse effects in all cases. Our study suggests that patients with cardiac disease are more predisposed to contrast extravasation than others. Further and larger studies are needed to confirm this trend. PMID:26090047

  14. Systemic mastocytosis: CT and US features of abdominal manifestations.

    PubMed

    Avila, N A; Ling, A; Worobec, A S; Mican, J M; Metcalfe, D D

    1997-02-01

    To study the imaging findings in patients with systemic mastocytosis and to correlate the findings with the severity of disease on the basis of an established classification system. Pathologic findings, when available, were correlated with imaging findings. Computed tomographic (CT) and ultrasound (US) scans and corresponding pathologic findings, when available, were retrospectively reviewed in 27 patients with systemic mastocytosis. Only five (19%) of the patients in our series had normal abdominal CT and/or US examination results. Common abdominal imaging findings associated with systemic mastocytosis were hepatosplenomegaly, retroperitoneal adenopathy, periportal adenopathy, mesenteric adenopathy, thickening of the omentum and the mesentery, and ascites. Less common findings included hepatofugal portal venous flow, Budd-Chiari syndrome, cavernous transformation of the portal vein, ovarian mass, and complications such as chloroma. The findings were more common in patients with category II and those with category III disease. Abdominal findings at CT and US are common in patients with systemic mastocytosis. Although the findings in patients with systemic mastocytosis are not specific to the disease, they are useful in directing further studies for diagnostic confirmation and in estimating the extent of systemic involvement.

  15. Abdominal and Pelvic CT

    MedlinePlus Videos and Cool Tools

    ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  16. CT Appearance of Traumatic Inferior Vena Cava Injury.

    PubMed

    Tsai, Richard; Raptis, Constantine; Schuerer, Douglas J; Mellnick, Vincent M

    2016-07-19

    CT plays a crucial role in the evaluation of stable patients with blunt and penetrating trauma in the emergency department. Among the more severe injuries that may occur in penetrating and blunt trauma are those to the inferior vena cava (IVC). The purpose of this study was to evaluate and differentiate the CT findings associated with penetrating versus blunt trauma to the IVC to aid the radiologist in diagnosing IVC injuries. Cases of blunt and penetrating IVC injury were retrospectively identified using search queries. Criteria for inclusion were preoperative contrast-enhanced CT and surgically confirmed caval injury or direct findings of caval injury on CT with patient death before surgical confirmation could be obtained. Twelve cases of traumatic IVC injury were identified over a 9-year period: six blunt and six penetrating. The most common finding was a retroperitoneal hematoma, seen in 75% of cases. Eighty-three percent of blunt injuries were associated with hepatic lacerations and contrast material extravasation. Thirty-three percent of penetrating IVC injuries were associated with extravasation. Contour abnormalities were seen in 50% of blunt and 17% of penetrating injuries to the IVC. All three cases of IVC injury resulting in mortality occurred in the retrohepatic segment. Injury to the IVC is frequently fatal in patients with penetrating or blunt trauma. The CT appearance of IVC injury is dichotomous between the two causes, with blunt IVC injury more likely to show extravasation, contour abnormality, and associated hepatic laceration. Injury of the retrohepatic IVC portends a poor outcome. With the continued use of CT for evaluation of trauma patients, the radiologist should be familiar with IVC injury and its different CT appearances.

  17. Relevance of early head CT scans following neurosurgical procedures: an analysis of 892 intracranial procedures at Rush University Medical Center.

    PubMed

    Fontes, Ricardo B V; Smith, Adam P; Muñoz, Lorenzo F; Byrne, Richard W; Traynelis, Vincent C

    2014-08-01

    Early postoperative head CT scanning is routinely performed following intracranial procedures for detection of complications, but its real value remains uncertain: so-called abnormal results are frequently found, but active, emergency intervention based on these findings may be rare. The authors' objective was to analyze whether early postoperative CT scans led to emergency surgical interventions and if the results of neurological examination predicted this occurrence. The authors retrospectively analyzed 892 intracranial procedures followed by an early postoperative CT scan performed over a 1-year period at Rush University Medical Center and classified these cases according to postoperative neurological status: baseline, predicted neurological change, unexpected neurological change, and sedated or comatose. The interpretation of CT results was reviewed and unexpected CT findings were classified based on immediate action taken: Type I, additional observation and CT; Type II, active nonsurgical intervention; and Type III, surgical intervention. Results were compared between neurological examination groups with the Fisher exact test. Patients with unexpected neurological changes or in the sedated or comatose group had significantly more unexpected findings on the postoperative CT (p < 0.001; OR 19.2 and 2.3, respectively) and Type II/III interventions (p < 0.001) than patients at baseline. Patients at baseline or with expected neurological changes still had a rate of Type II/III changes in the 2.2%-2.4% range; however, no patient required an immediate return to the operating room. Over a 1-year period in an academic neurosurgery service, no patient who was neurologically intact or who had a predicted neurological change required an immediate return to the operating room based on early postoperative CT findings. Obtaining early CT scans should not be a priority in these patients and may even be cancelled in favor of MRI studies, if the latter have already been planned

  18. SU-E-I-46: Sample-Size Dependence of Model Observers for Estimating Low-Contrast Detection Performance From CT Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reiser, I; Lu, Z

    2014-06-01

    Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions includedmore » two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task.« less

  19. Spleen in haematological malignancies: spectrum of imaging findings

    PubMed Central

    Saboo, S S; Krajewski, K M; O'Regan, K N; Giardino, A; Brown, J R; Ramaiya, N; Jagannathan, J P

    2012-01-01

    Imaging morphology and metabolic activity of splenic lesions is of paramount importance in patients with haematological malignancies; it can alter tumour staging, treatment protocols and overall prognosis. CT, MRI and positron emission tomography (PET)/CT have been shown to be powerful tools for the non-invasive assessment of splenic involvement in various haematological malignancies. Since many haematological malignancies and non-neoplastic conditions can involve the spleen and imaging manifestations can overlap, imaging and clinical findings outside of the spleen should be looked for to narrow the differential diagnosis; confirmation can be obtained by pathological findings. Radiologists should be familiar with the cross-sectional imaging patterns of haematological malignancies involving the spleen as well as non-neoplastic splenic findings common in these patients to facilitate their care and follow-up. This pictorial review provides the common and uncommon imaging appearances and complications of various haematological malignancies involving the spleen on CT, MRI and PET/CT, and common pitfalls in diagnosis. PMID:22096219

  20. Clinical Decision Rules for Paediatric Minor Head Injury: Are CT Scans a Necessary Evil?

    PubMed

    Thiam, Desmond Wei; Yap, Si Hui; Chong, Shu Ling

    2015-09-01

    High performing clinical decision rules (CDRs) have been derived to predict which head-injured child requires a computed tomography (CT) of the brain. We set out to evaluate the performance of these rules in the Singapore population. This is a prospective observational cohort study of children aged less than 16 who presented to the emergency department (ED) from April 2014 to June 2014 with a history of head injury. Predictor variables used in the Canadian Assessment of Tomography for Childhood Head Injury (CATCH), Children's Head Injury Algorithm for the Prediction of Important Clinical Events (CHALICE) and Pediatric Emergency Care Applied Research Network (PECARN) CDRs were collected. Decisions on CT imaging and disposition were made at the physician's discretion. The performance of the CDRs were assessed and compared to current practices. A total of 1179 children were included in this study. Twelve (1%) CT scans were ordered; 6 (0.5%) of them had positive findings. The application of the CDRs would have resulted in a significant increase in the number of children being subjected to CT (as follows): CATCH 237 (20.1%), CHALICE 282 (23.9%), PECARN high- and intermediate-risk 456 (38.7%), PECARN high-risk only 45 (3.8%). The CDRs demonstrated sensitivities of: CATCH 100% (54.1 to 100), CHALICE 83.3% (35.9 to 99.6), PECARN 100% (54.1 to 100), and specificities of: CATCH 80.3% (77.9 to 82.5), CHALICE 76.4% (73.8 to 78.8), PECARN high- and intermediate-risk 61.6% (58.8 to 64.4) and PECARN high-risk only 96.7% (95.5 to 97.6). The CDRs demonstrated high accuracy in detecting children with positive CT findings but direct application in areas with low rates of significant traumatic brain injury (TBI) is likely to increase unnecessary CT scans ordered. Clinical observation in most cases may be a better alternative.

  1. Added value of SPECT/spiral CT versus SPECT or CT alone in diagnosing solitary skeletal lesions.

    PubMed

    Zhang, Yiqiu; Li, Beilei; Shi, Hongcheng; Yu, Haojun; Gu, Yushen; Xiu, Yan

    2017-08-14

    The aim of this study was to investigate the added value of SPECT/spiral CT versus SPECT or CT alone in the differential diagnosis of solitary skeletal lesions. This was a retrospective study on a total of 69 patients who had a solitary skeletal "hot spot" that could not be definitively diagnosed using planar scintigraphy. Thus, SPECT/spiral CT was performed on the indeterminate lesions. SPECT, CT and SPECT/spiral CT images were independently interpreted by two experienced doctors who have both identification of CT and nuclear medicine. Each lesion was graded on a 4-point diagnostic scale (1: benign, 2: likely benign, 3: likely malignant, 4: malignant). The final diagnosis of each lesion was based on pathological confirmation after surgery within 3 weeks of the bone scan. Final diagnoses based on the pathological results revealed that 43 of the 69 patients were diagnosed with malignancy, and the remaining 26 patients were diagnosed as having benign lesions. For SPECT and CT scans, both of the reviewers rated 55.1 % (38/69) and 37.7 % (26/69) of lesions as equivocal, with the help of SPECT/CT, 33.3 % (23/69) of lesions were rated as equivocal. The diagnostic accuracies of SPECT, CT alone and SPECT/CT were 66.7 % (46/69) ,82.6 % (57/69) and 85.5 %(59/69), respectively. The kappa scores for the degree of agreement between SPECT, CT alone or SPECT/CT with pathological results were 0.185 (p = 0.054) , 0.612 (p < 0.001) and 0.671 (p < 0.001), respectively. Compared with SPECT or imaging alone, SPECT/spiral CT imaging was more accurate and valuable in the differential diagnosis of solitary skeletal lesions and resulted in significantly fewer equivocal findings.

  2. Characteristic findings of magnetic resonance imaging (MRI) and computed tomography (CT) for severe chronic laminitis in a Thoroughbred horse

    PubMed Central

    YAMADA, Kazutaka; INUI, Tomohiro; ITOH, Megumi; YANAGAWA, Masashi; SATO, Fumio; TOMINARI, Masataka; MIZOBE, Fumiaki; KISHIMOTO, Miori; SASAKI, Naoki

    2017-01-01

    ABSTRACT A Thoroughbred horse with severe chronic laminitis of both forelimbs was evaluated on the same day with magnetic resonance imaging (MRI) and computed tomography (CT). Both MRI and CT revealed loss of the dorsal aspect of the cortical bone of the 3rd phalanx and sclerosis. CT reflected the status of the horny layer and bone of the affected feet, while MRI depicted inflammation of the laminar corium, together with tendon edema. On the 3-dimensional CT venogram, vessels were visualized in both the right and left forelimbs, although there was a difference in the vasculature of the coronary plexus and circumflex vessels between the right and left forelimbs. A combination of both MRI and CT provides detailed information regarding pathological conditions. PMID:28955162

  3. Correlation between presumed sinusitis-induced pain and paranasal sinus computed tomographic findings.

    PubMed

    Mudgil, Shikha P; Wise, Scott W; Hopper, Kenneth D; Kasales, Claudia J; Mauger, David; Fornadley, John A

    2002-02-01

    The correlation between facial and/or head pain in patients clinically suspected of having sinusitis and actual localized findings on sinus computed tomographic (CT) imaging are poorly understood. To prospectively evaluate the relationship of paranasal sinus pain symptoms with CT imaging. Two hundred consecutive patients referred by otolaryngologists and internists for CT of the paranasal sinuses participated by completing a questionnaire immediately before undergoing CT. Three radiologists blinded to the patients' responses scored the degree of air/fluid level, mucosal thickening, bony reaction, and mucus retention cysts using a graded scale of severity (0 to 3 points). The osteomeatal complexes and nasolacrimal ducts were also evaluated for patency. Bivariate analysis was performed to evaluate the relationship between patients' localized symptoms and CT findings in the respective sinus. One hundred sixty-three patients (82%) reported having some form of facial pain or headache. The right temple/forehead was the most frequently reported region of maximal pain. On CT imaging the maxillary sinus was the most frequently involved sinus. Bivariate analysis failed to show any relationship between patient symptoms and findings on CT. Patients with a normal CT reported a mean 5.88 sites of facial or head pain versus 5.45 sites for patients with an abnormal CT. Patient-based responses of sinonasal pain symptoms fail to correlate with findings in the respective sinuses. CT should therefore be reserved for delineating the anatomy and degree of sinus disease before surgical intervention.

  4. The influence of CT based attenuation correction on PET/CT registration: an evaluation study

    NASA Astrophysics Data System (ADS)

    Yaniv, Ziv; Wong, Kenneth H.; Banovac, Filip; Levy, Elliot; Cleary, Kevin

    2007-03-01

    We are currently developing a PET/CT based navigation system for guidance of biopsies and radiofrequency ablation (RFA) of early stage hepatic tumors. For these procedures, combined PET/CT data can potentially improve current interventions. The diagnostic efficacy of biopsies can potentially be improved by accurately targeting the region within the tumor that exhibits the highest metabolic activity. For RFA procedures the system can potentially enable treatment of early stage tumors, targeting tumors before structural abnormalities are clearly visible on CT. In both cases target definition is based on the metabolic data (PET), and navigation is based on the spatial data (CT), making the system highly dependent upon accurate spatial alignment between these data sets. In our institute all clinical data sets include three image volumes: one CT, and two PET volumes, with and without CT-based attenuation correction. This paper studies the effect of the CT-based attenuation correction on the registration process. From comparing the pairs of registrations from five data sets we observe that the point motion magnitude difference between registrations is on the same scale as the point motion magnitude in each one of the registrations, and that visual inspection cannot identify this discrepancy. We conclude that using non-rigid registration to align the PET and CT data sets is too variable, and most likely does not provide sufficient accuracy for interventional procedures.

  5. Diagnosing Early Ischemic Changes with the Latest-Generation Flat Detector CT: A Comparative Study with Multidetector CT.

    PubMed

    Maier, I L; Leyhe, J R; Tsogkas, I; Behme, D; Schregel, K; Knauth, M; Schnieder, M; Liman, J; Psychogios, M-N

    2018-05-01

    One-stop management of mechanical thrombectomy-eligible patients with large-vessel occlusion represents an innovative approach in acute stroke treatment. This approach reduces door-to-reperfusion times by omitting multidetector CT, using flat detector CT as pre-mechanical thrombectomy imaging. The purpose of this study was to compare the diagnostic performance of the latest-generation flat detector CT with multidetector CT. Prospectively derived data from patients with ischemic stroke with large-vessel occlusion and mechanical thrombectomy were analyzed in this monocentric study. All included patients underwent multidetector CT before referral to our comprehensive stroke center and flat detector CT in the angiography suite before mechanical thrombectomy. Diagnosis of early ischemic signs, quantified by the ASPECTS, was compared between modalities using cross tables, the Pearson correlation, and Bland-Altman plots. The predictive value of multidetector CT- and flat detector CT-derived ASPECTS for functional outcome was investigated using area under the receiver operating characteristic curve analysis. Of 25 patients, 24 (96%) had flat detector CT with sufficient diagnostic quality. Median multidetector CT and flat detector CT ASPECTSs were 7 (interquartile range, 5.5-9 and 4.25-8, respectively) with a mean period of 143.6 ± 49.5 minutes between both modalities. The overall sensitivity was 85.1% and specificity was 83.1% for flat detector CT ASPECTS compared with multidetector CT ASPECTS as the reference technique. Multidetector CT and flat detector CT ASPECTS were strongly correlated ( r = 0.849, P < .001) and moderately predicted functional outcome (area under the receiver operating characteristic curve, 0.738; P = .007 and .715; P = .069, respectively). Determination of ASPECTS on flat detector CT is feasible, showing no significant difference compared with multidetector CT ASPECTS and a similar predictive value for functional outcome. Our findings support the

  6. Diagnostic Performance of 11C-choline PET/CT and FDG PET/CT in Prostate Cancer.

    PubMed

    Kitajima, Kazuhiro; Yamamoto, Shingo; Odawara, Soichi; Kobayashi, Kaoru; Fujiwara, Masayuki; Kamikonya, Norihiko; Fukushima, Kazuhito; Nakanishi, Yukako; Hashimoto, Takahiko; Yamada, Yusuke; Suzuki, Toru; Kanematsu, Akihiro; Nojima, Michio; Yamakado, Koichiro

    2018-06-01

    We compared 11C-choline and FDG PET/CT scan findings for the staging and restaging of prostate cancer. Twenty Japanese prostate cancer patients underwent 11C-choline and FDG PET/CT before (n=5) or after (n=15) treatment. Using a five-point scale, we compared these scanning modalities regarding patient- and lesion-based diagnostic performance for local recurrence, untreated primary tumor, and lymph node and bony metastases. Of the 20 patients, documented local lesions, and node and bony metastases were present in 11 (55.0%), 9 (45.0%), and 13 (65.0%), respectively. The patient-based sensitivity/specificity/accuracy/area under the receiver-operating-characteristic curve (AUC) values for 11C-choline-PET/CT for diagnosing local lesions were 90.9% /100%/ 95.0% / 1.0, whereas those for FDG-PET/CT were 45.5% /100%/ 75.0% / 0.773. Those for 11C-choline-PET/CT for node metastasis were 88.9% /100%/ 95.0% / 0.944, and those for FDG-PET/CT were 44.4%/100%/75.0%/0.722. Those for 11C-choline-PET/CT for bone metastasis were 84.6%/100%/90.0%/0.951, and those for FDG-PET/CT were 76.9% /100%/ 85.0% / 0.962. The AUCs for local lesion and node metastasis differed significantly (p=0.0039, p=0.011, respectively). The lesion-based detection rates of 11C-choline compared to FDG PET/CT for local lesion, and node and bone metastases were 91.7% vs. 41.7%, 92.0% vs. 32.0%, and 94.8% vs. 83.0% (p=0.041, p=0.0030, p<0.0001), respectively. 11C-choline-PET/CT is more useful for the staging and restaging of prostate cancer than FDG-PET/CT in Japanese men.

  7. WE-B-207-00: CT Lung Cancer Screening Part 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the

  8. Primary perivascular epithelioid cell tumors of the liver: CT/MRI findings and clinical outcomes.

    PubMed

    O'Malley, Martin E; Chawla, Tanya P; Lavelle, Lisa P; Cleary, Sean; Fischer, Sandra

    2017-06-01

    The purpose of our study was to describe the CT and MRI features of primary PEComas of the liver and to document the associated clinical outcomes. Retrospective study included 20 patients with primary hepatic perivascular epithelioid cell tumors (PEComa) with pathology and clinical outcomes for correlation. Study group included 20 patients: 16 women, 4 men; mean age 53 (range 35-77) years. Initial pathology diagnoses were classic angiomyolipoma (AML) (n = 11), epithelioid AML (n = 7), and PEComa not otherwise specified (n = 2). Mean tumor size was 5.1 (range 1.3-15.0) cm. CT/MRI features included well-defined margins 20/20 (100%), arterial enhancement 18/19 (95%), subcapsular location 17/20 (85%), heterogeneous 16/20 (80%), dysmorphic vessels 14/20 (70%), fat 13/20 (65%), hemorrhage 4/20 (20%), cystic components 4/20 (20%), and calcification 1/20 (5%). At the time of discovery, 18 patients were asymptomatic and their tumors were incidentally detected on imaging, and 2 patients were symptomatic. Ultimately, 18 tumors were benign and 2 developed metastases. On CT/MRI, most primary hepatic PEComas were well-defined, arterial enhancing, subcapsular, heterogeneous masses that often had dysmorphic vessels and contained fat. Most tumors were benign but complications included local symptoms, bleeding, and malignant change.

  9. Classifying CT/MR findings in patients with suspicion of hepatocellular carcinoma: Comparison of liver imaging reporting and data system and criteria-free Likert scale reporting models.

    PubMed

    Zhang, Yu-Dong; Zhu, Fei-Peng; Xu, Xun; Wang, Qing; Wu, Chen-Jiang; Liu, Xi-Sheng; Shi, Hai-Bin

    2016-02-01

    To compare the Liver Imaging Reporting and Data System (LI-RADS) and a criteria-free Likert scale (LS) reporting models for classifying computed tomography/magnetic resonance imaging (CT/MR) findings of suspicious hepatocellular carcinoma (HCC). Imaging data of 281 hepatic nodules in 203 patients were retrospectively included. Imaging characteristics including diameter, arterial hyperenhancement, washout, and capsule were reviewed independently by two groups of readers using LI-RADS and LS (range, score 1-5). LS is primarily based on the overall impression of image findings without using fixed criteria. Interreader agreement (IRA), intraclass agreement (ICA), and diagnostic performance were determined by Fleiss, Cohen's kappa (κ), and logistic regression, respectively. There were 167 contrast-enhanced CT (CECT) versus 114 MR data. Overall, IRA was moderate (κ = 0.47, 0.52); IRA was moderate-to-good for arterial hyperenhancement, washout, and capsule (κ = 0.56-0.69); excellent for diameter and tumor embolus (κ = 0.99). Overall, ICA between LI-RADS and LS was moderate (κ = 0.44-0.50); ICA was good for scores 1-2 (κ = 0.71-0.90), moderate for scores 3 and 5 (κ = 0.41-0.52), but very poor for score 4 (κ = 0.11-0.19). LI-RADS produced significantly lower accuracy (78.6% vs. 87.2%) and sensitivity (72.1% vs. 92.8%), higher specificity (97.3% vs. 71.2%) and positive likelihood ratio (+LR: 26.32 vs. 3.23) in diagnosis of HCC. CECT produced relatively low IRA, ICA, and diagnostic ability against MR. There were substantial variations in liver observations between LI-RADS and LS. Further study is needed to investigate ICA between CECT and MR. © 2015 Wiley Periodicals, Inc.

  10. Post-therapy lesions in patients with non-Hodgkin's lymphoma characterized by 18F-FDG PET/CT-guided biopsy using automated robotic biopsy arm.

    PubMed

    Radhakrishnan, Renjith K; Mittal, Bhagwant R; Basher, Rajender K; Prakash, Gaurav; Malhotra, Pankaj; Kalra, Naveen; Das, Ashim

    2018-01-01

    The aim of this study was to analyse the positive predictive value (PPV) of post-therapy fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT performed for response or recurrence evaluation in patients with non-Hodgkin's lymphoma (NHL) and to appraise the diagnostic utility of F-FDG PET/CT-guided biopsy in this setting. A total of 17 patients with NHL showing F-FDG avid lesions in F-FDG PET/CT performed for response or recurrence assessment underwent F-FDG PET/CT-guided biopsy using automated robotic biopsy arm needle navigation technique. The objectives were analysed in reference to histopathology. In all, 15 of the 17 (88.5%) procedures yielded adequate representative tissue samples. Nine out of 15 lesions were positive for residual disease and the remaining revealed benign findings on histopathology. One patient with inconclusive biopsy underwent surgical resection and histopathology confirmed the presence of residual disease. PPV of theF-FDG PET/CT was observed to be 62.5% (10/16). F-FDG PET/CT for response evaluation in NHL possesses a low PPV and hence warrants histopathological correlation when F-FDG PET/CT findings influence management decision. Diagnostic yield of F-FDG PET/CT-guided biopsy is high and has the potential to reduce sampling errors.

  11. WE-B-207-02: CT Lung Cancer Screening and the Medical Physicist: A Dosimetry Summary of CT Participants in the National Lung Cancer Screening Trial (NLST)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, C.

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the

  12. Quantitative 3D Ultrashort Time-to-Echo (UTE) MRI and Micro-CTCT) Evaluation of the Temporomandibular Joint (TMJ) Condylar Morphology

    PubMed Central

    Geiger, Daniel; Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B.

    2014-01-01

    Objective Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. Purpose of this study was to determine accuracy of novel 3D-UTE MRI versus micro-CTCT) for quantitative evaluation of mandibular condyle morphology. Material & Methods Nine TMJ condyle specimens were harvested from cadavers (2M, 3F; Age 85 ± 10 yrs., mean±SD). 3D-UTE MRI (TR=50ms, TE=0.05 ms, 104 μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18 μm isotropic-voxel) was performed. MR datasets were spatially-registered with μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature and segmented volume of the bone were determined using intraclass correlation correlation (ICC) analyses. Results Between MRI and μCT, the average deviation of surface coordinates was 0.19±0.15 mm, slightly higher than spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7±6.5% and 6.6±6.2%, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature and segmented volumes were respectively 0.892, 0.893 and 0.972. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999 and 0.997 respectively. Fibrocartilage thickness was 0.55±0.11 mm, as previously described in literature for grossly normal TMJ samples. Conclusion 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  13. Aortitis in giant cell arteritis: diagnosis with FDG PET/CT and agreement with CT angiography.

    PubMed

    Hommada, Mona; Mekinian, Arsène; Brillet, Pierre-Yves; Abad, Sébastien; Larroche, Claire; Dhôte, Robin; Fain, Olivier; Soussan, Michael

    2017-11-01

    To assess the detection rate of aortitis in giant cell arteritis (GCA) with fluorodeoxyglucose positron emission tomography/computed tomography (PET) and to compare the findings with CT angiography (CTA). Fifty-two GCA patients and 27 controls were included. GCA patients had a PET scan at diagnosis (35/52) or during relapse (17/52). Concomitant CTA was performed in 35/52 patients. Aortitis was defined as FDG uptake higher than the liver for PET and wall thickness≥3mm for CTA. Agreement between PET and CTA was evaluated by the kappa coefficient and Spearman correlation coefficient. Aortitis was diagnosed using PET in 40% (14/35) of patients at diagnosis and in 0% of controls (0/27). Agreement was perfect between PET and CT at a patient-based level, and very good at a vascular segment-based level (kappa: 0.72 to 1). PET was positive in 35% (6/17) of patients scanned during GCA relapse, showing aortitis (n=4) and/or articular uptake (n=4). Discrepancies between PET and CT were observed only in relapsing GCA (n=3). Correlation between the maximum standardized uptake value and wall thickness was moderate at diagnosis (r: 0.57 to 0.7) and not statistically significant during relapse. The detection rate of aortitis in GCA patients using PET is 40%, approximately in the range of CTA rates, suggesting that the two techniques have similar sensitivity. PET seems valuable in relapsing GCA, allowing the detection of vascular and articular activities. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Predictors of Urgent Findings on Abdominopelvic CT in Patients with Crohn's Disease Presenting to the Emergency Department.

    PubMed

    Jung, Yoon Suk; Park, Dong Il; Hong, Sung Noh; Kim, Eun Ran; Kim, Young Ho; Cheon, Jae Hee; Eun, Chang Soo; Han, Dong Soo; Lee, Chang Kyun; Kim, Jae Hak; Huh, Kyu Chan; Yoon, Soon Man; Song, Hyun Joo; Shin, Jeong Eun; Jeon, Seong Ran

    2015-04-01

    Patients with Crohn's disease (CD) are frequently exposed to diagnostic radiation, mainly as a result of abdominopelvic computed tomography (APCT) examinations. However, there are limited data on the impact of APCT on clinical management in this population. To investigate clinical predictors of urgent findings on APCT in patients with CD who presented to the emergency department (ED). A retrospective study was performed among patients with CD presenting to 11 EDs with a gastrointestinal complaint. The primary outcome, OPAN (obstruction, perforation, abscess, or non-CD-related urgent findings), included new or worsening CD-related urgent findings or non-CD-related urgent findings that required urgent or emergency treatment. Variables with P < 0.1 in univariate analyses were included in a multivariable logistic regression model. Of the 266 APCTs performed, 103 (38.7 %) had OPAN and 113 (42.5 %) required changes in treatment plan. Stricturing or penetrating disease (odds ratio [OR] 2.72, 95 % confidence interval [CI] 1.21-6.13), heart rate >100 beats/min (OR 2.33, 95 % CI 1.10-4.93), leukocyte count >10,000/mm(3) (OR 4.38, 95 % CI 2.10-9.13), and CRP >2.5 mg/dL (OR 3.11, 95 % CI 1.23-7.86) were identified as the independent predictors of OPAN, whereas biologic agent use (OR 0.37; 95 % CI 0.15-0.90) was identified as the negative predictor in patients with CD. Only 39 % of the APCTs performed in the ED among patients with CD showed urgent findings. Stricturing or penetrating disease, tachycardia, leukocytosis, and high CRP level were predictors of urgent CT findings, while biologic agent use was a negative predictor. To reduce unnecessary radiation exposure, the selection process for CD patients referred for APCT must be improved.

  15. A framework for optimizing micro-CT in dual-modality micro-CT/XFCT small-animal imaging system

    NASA Astrophysics Data System (ADS)

    Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew; Cho, Sang Hyun

    2017-09-01

    Dual-modality Computed Tomography (CT)/X-ray Fluorescence Computed Tomography (XFCT) can be a valuable tool for imaging and quantifying the organ and tissue distribution of small concentrations of high atomic number materials in small-animal system. In this work, the framework for optimizing the micro-CT imaging system component of the dual-modality system is described, either when the micro-CT images are concurrently acquired with XFCT and using the x-ray spectral conditions for XFCT, or when the micro-CT images are acquired sequentially and independently of XFCT. This framework utilizes the cascaded systems analysis for task-specific determination of the detectability index using numerical observer models at a given radiation dose, where the radiation dose is determined using Monte Carlo simulations.

  16. Optimization of the scan protocols for CT-based material extraction in small animal PET/CT studies

    NASA Astrophysics Data System (ADS)

    Yang, Ching-Ching; Yu, Jhih-An; Yang, Bang-Hung; Wu, Tung-Hsin

    2013-12-01

    We investigated the effects of scan protocols on CT-based material extraction to minimize radiation dose while maintaining sufficient image information in small animal studies. The phantom simulation experiments were performed with the high dose (HD), medium dose (MD) and low dose (LD) protocols at 50, 70 and 80 kVp with varying mA s. The reconstructed CT images were segmented based on Hounsfield unit (HU)-physical density (ρ) calibration curves and the dual-energy CT-based (DECT) method. Compared to the (HU;ρ) method performed on CT images acquired with the 80 kVp HD protocol, a 2-fold improvement in segmentation accuracy and a 7.5-fold reduction in radiation dose were observed when the DECT method was performed on CT images acquired with the 50/80 kVp LD protocol, showing the possibility to reduce radiation dose while achieving high segmentation accuracy.

  17. Incidental findings on computed tomography scans in children with mild head trauma.

    PubMed

    Ortega, Henry W; Vander Velden, Heidi; Reid, Samuel

    2012-09-01

    Computed tomography (CT) scans are frequently used in managing traumatic brain injuries in children. To assess incidental findings in children with head trauma undergoing CT scan and to describe any associated clinical ramifications. Retrospective review of 524 children treated in 2 emergency departments for closed head injury who received a CT scan. Overall, 137 (26.2%) patients had an incidental finding on CT scan. The most common incidental finding was sinus opacification with an air fluid level (115/137, 83.9%). Thirty-five interventions were reported in children with incidental findings. Children 2 years old or younger were more likely to receive a prescription for antibiotics (relative risk [RR] = 2.66, 95% confidence interval [CI] = 1.08-6.51) and be referred to a specialist (RR = 10.26, 95% CI = 3.56-29.56) than older children. Incidental findings in minor head trauma are common. Clinicians should be prepared to address these findings if clinically indicated.

  18. CT of abdominal tuberculosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Epstein, B.M.; Mann, J.H.

    1982-11-01

    Intraabdominal tuberculosis (TB) presents with a wide variety of clinical and radiologic features. Besides the reported computed tomographic (CT) finding of high-density ascites in tuberculous peritonitis, this report describes additional CT features highly suggestive of abdominal tuberculosis in eight cases: (1) irregular soft-tissue densities in the omental area; (2) low-density masses surrounded by thick solid rims; (3) a disorganized appearance of soft-tissue densities, fluid, and bowel loops forming a poorly defined mass; (4) low-density lymph nodes with a multilocular appearance after intravenous contrast administration; and (5) possibly high-density ascites. The differential diagnosis of these features include lymphoma, various forms ofmore » peritonitis, peritoneal carcinomatosis, and peritoneal mesothelioma. It is important that the CT features of intraabdominal tuberculosis be recognized in order that laparotomy be avoided and less invasive procedures (e.g., laparoscopy, biopsy, or a trial of antituberculous therapy) be instituted.« less

  19. Improved proton CT imaging using a bismuth germanium oxide scintillator.

    PubMed

    Tanaka, Sodai; Nishio, Teiji; Tsuneda, Masato; Matsushita, Keiichiro; Kabuki, Shigeto; Uesaka, Mitsuru

    2018-02-02

    Range uncertainty is among the most formidable challenges associated with the treatment planning of proton therapy. Proton imaging, which includes proton radiography and proton computed tomography (pCT), is a useful verification tool. We have developed a pCT detection system that uses a thick bismuth germanium oxide (BGO) scintillator and a CCD camera. The current method is based on a previous detection system that used a plastic scintillator, and implements improved image processing techniques. In the new system, the scintillation light intensity is integrated along the proton beam path by the BGO scintillator, and acquired as a two-dimensional distribution with the CCD camera. The range of a penetrating proton is derived from the integrated light intensity using a light-to-range conversion table, and a pCT image can be reconstructed. The proton range in the BGO scintillator is shorter than in the plastic scintillator, so errors due to extended proton ranges can be reduced. To demonstrate the feasibility of the pCT system, an experiment was performed using a 70 MeV proton beam created by the AVF930 cyclotron at the National Institute of Radiological Sciences. The accuracy of the light-to-range conversion table, which is susceptible to errors due to its spatial dependence, was investigated, and the errors in the acquired pixel values were less than 0.5 mm. Images of various materials were acquired, and the pixel-value errors were within 3.1%, which represents an improvement over previous results. We also obtained a pCT image of an edible chicken piece, the first of its kind for a biological material, and internal structures approximately one millimeter in size were clearly observed. This pCT imaging system is fast and simple, and based on these findings, we anticipate that we can acquire 200 MeV pCT images using the BGO scintillator system.

  20. Improved proton CT imaging using a bismuth germanium oxide scintillator

    NASA Astrophysics Data System (ADS)

    Tanaka, Sodai; Nishio, Teiji; Tsuneda, Masato; Matsushita, Keiichiro; Kabuki, Shigeto; Uesaka, Mitsuru

    2018-02-01

    Range uncertainty is among the most formidable challenges associated with the treatment planning of proton therapy. Proton imaging, which includes proton radiography and proton computed tomography (pCT), is a useful verification tool. We have developed a pCT detection system that uses a thick bismuth germanium oxide (BGO) scintillator and a CCD camera. The current method is based on a previous detection system that used a plastic scintillator, and implements improved image processing techniques. In the new system, the scintillation light intensity is integrated along the proton beam path by the BGO scintillator, and acquired as a two-dimensional distribution with the CCD camera. The range of a penetrating proton is derived from the integrated light intensity using a light-to-range conversion table, and a pCT image can be reconstructed. The proton range in the BGO scintillator is shorter than in the plastic scintillator, so errors due to extended proton ranges can be reduced. To demonstrate the feasibility of the pCT system, an experiment was performed using a 70 MeV proton beam created by the AVF930 cyclotron at the National Institute of Radiological Sciences. The accuracy of the light-to-range conversion table, which is susceptible to errors due to its spatial dependence, was investigated, and the errors in the acquired pixel values were less than 0.5 mm. Images of various materials were acquired, and the pixel-value errors were within 3.1%, which represents an improvement over previous results. We also obtained a pCT image of an edible chicken piece, the first of its kind for a biological material, and internal structures approximately one millimeter in size were clearly observed. This pCT imaging system is fast and simple, and based on these findings, we anticipate that we can acquire 200 MeV pCT images using the BGO scintillator system.

  1. The role of pubic symphyseal CT arthrography in the imaging of athletic pubalgia.

    PubMed

    McArthur, Tatum A; Narducci, Carl A; Lopez-Ben, Robert R

    2014-11-01

    The purpose of this article is to describe the results of pubic symphyseal CT arthrography compared with MRI in patients with suspected athletic pubalgia. In this study, two musculoskeletal radiologists retrospectively searched our department's PACS to identify patients who had undergone CT-guided injection with concurrent pubic symphyseal CT arthrography for evaluation and treatment of groin pain, sports hernia, or athletic pubalgia over a 5.5-year period (January 1, 2007-July 1, 2012). The MR and CT arthrography images and reports, clinical findings at presentation, pain response to injection, and operative findings were reviewed using the electronic medical record. Twelve patients underwent CT-guided injection and pubic symphyseal CT arthrography at our institution during the 5.5-year study period. Nine of the 12 patients had undergone MRI before the procedure. In two of the three patients who had not undergone MRI, CT arthrography revealed secondary clefts. Three of four patients who had secondary clefts on MRI had contrast extravasation reproducing the cleft at CT. Three patients had MRI findings suggestive of athletic pubalgia without MRI evidence of a secondary cleft; in all three of these patients, CT arthrography showed a secondary cleft. In four patients, CT arthrography revealed tendon tears at the adductor origin that were not apparent on MRI. All 12 patients reported decreased groin pain after injection. Pubic symphyseal CT arthrography is a useful technique for the diagnosis and short-term pain relief of athletic pubalgia. It can be used to identify secondary clefts and to detect tendon tears that can potentially be overlooked on MRI.

  2. Conventional 3D staging PET/CT in CT simulation for lung cancer: impact of rigid and deformable target volume alignments for radiotherapy treatment planning.

    PubMed

    Hanna, G G; Van Sörnsen De Koste, J R; Carson, K J; O'Sullivan, J M; Hounsell, A R; Senan, S

    2011-10-01

    Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans. 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTV(CT)) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Dice's similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan. When the GTV(CT) delineated on the staging scan after both rigid registration and deformation was compared with the GTV(CT)on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p = 0.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration. No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.

  3. [Retrospective computation of the ISS in multiple trauma patients: Potential pitfalls and limitations of findings in full body CT scans].

    PubMed

    Bogner, V; Brumann, M; Kusmenkov, T; Kanz, K G; Wierer, M; Berger, F; Mutschler, W

    2016-03-01

    The Injury Severity Score (ISS) is a well-established anatomical scoring system for polytraumatized patients. However, any inaccuracy in the Abbreviated Injury Score (AIS) directly increases the ISS impreciseness. Using the full body computed tomography (CT) scan report, ISS computation can be associated with certain pitfalls. This study evaluates interpretation variations depending on radiological reports and indicates requirements to reliably determine the ISS. The ISS of 81 polytraumatized patients was calculated based on the full body CT scan report. If an injury could not be attributed to a precise AIS cipher, the minimal and maximal ISS was computed. Real ISS included all conducted investigations, intraoperative findings, and final medical reports. The differences in ISS min, ISS max, and ISS real were evaluated using the Kruskal-Wallis test (p<0.05) and plotted in a linear regression analysis. Mean ISS min was 24.0 (± 0.7 SEM) points, mean ISS real 38.6 (±1.3 SEM) and mean ISS max was 48.3 (±1.4 SEM) points. All means were significantly different compared to one another (p<0.001). The difference between possible and real ISS showed a distinctive variation. Mean deviation was 9.7 (±0.9 SEM) points downward and 14.5 (±1.1 SEM) points upward. The difference between deviation to ISS min and ISS max was highly significant (p<0.001). Objectification of injury severity in polytraumatized patients using the ISS is an internationally well-established method in clinical and scientific settings. The full body CT scan report must meet distinct criteria and has to be written in acquaintance to the AIS scale if intended to be used for correct ISS computation.

  4. Is the routine CT head scan justified for psychiatric patients? A prospective study.

    PubMed Central

    Ananth, J; Gamal, R; Miller, M; Wohl, M; Vandewater, S

    1993-01-01

    Thirty-four psychiatric patients, assessed for a physical illness that was missed during diagnosis, underwent a CT scan. After investigation, the diagnosis of 14 patients changed from a functional to an organic illness. In nine patients, the CT scan was reported to be abnormal, and yet only two were diagnosed as having an organic syndrome. In seven patients, the CT scan was normal but the patients had an undisputed organic brain syndrome. These findings indicate that the use of CT scans should be restricted to cases in which the diagnosis is seriously in question. The clinical findings should dictate the use of CT scans either to clarify or to complement them. PMID:8461285

  5. The impact of FDG-PET/CT in the management of patients with vulvar and vaginal cancer.

    PubMed

    Robertson, N L; Hricak, H; Sonoda, Y; Sosa, R E; Benz, M; Lyons, G; Abu-Rustum, N R; Sala, E; Vargas, H A

    2016-03-01

    To evaluate the changes in prognostic impression and patient management following PET/CT in patients with vulvar and vaginal carcinoma; and to compare PET/CT findings with those of conventional imaging modalities. We summarized prospectively and retrospectively collected data for 50 consecutive patients from our institution that enrolled in the National Oncologic PET Registry and underwent FDG-PET/CT for a suspected or known primary or recurrent vulvar/vaginal cancer. 54/83 (65%) studies included had a diagnosis of vulvar cancer, and the remaining 29/83 (35%), a diagnosis of vaginal cancer. Following FDG-PET/CT, the physician's prognostic impression changed in 51% of cases. A change in patient management, defined as a change to/from a non-interventional strategy (observation or additional imaging), to/from an interventional strategy (biopsy or treatment), was documented in 36% of studies. The electronic records demonstrated that 95% of the management strategies recorded in the physician questionnaires were implemented as planned. MRI and/or CT were performed within one month of the FDG-PET/CT in 20/83 (24%) and 28/83 (34%) cases, respectively. FDG-PET/CT detected nodes suspicious for metastases on 29/83 (35%) studies performed. MRI and CT detected positive nodes on 6 and 11 studies respectively. Distant metastases were identified in 10 cases imaged with FDG-PET and 5 cases that had additional conventional CT imaging. All suspicious lesions seen on CT were positively identified on PET/CT. In 4 cases, an abnormality identified on PET/CT, was not seen on diagnostic CT. FDG-PET/CT may play an important role in the management of vulvar and vaginal carcinoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Thoracic spine CT scan

    MedlinePlus

    ... take this medicine. Find out if the CT machine has a weight limit if you weigh more than 300 pounds (135 kilograms). Too much weight can cause damage to the scanner. You will be asked to remove jewelry and wear a hospital gown during the study.

  7. Diagnostic Value of 18F-FDG PET/CT Versus MRI in the Setting of Antibody-Specific Autoimmune Encephalitis.

    PubMed

    Solnes, Lilja B; Jones, Krystyna M; Rowe, Steven P; Pattanayak, Puskar; Nalluri, Abhinav; Venkatesan, Arun; Probasco, John C; Javadi, Mehrbod S

    2017-08-01

    Diagnosis of autoimmune encephalitis presents some challenges in the clinical setting because of varied clinical presentations and delay in obtaining antibody panel results. We examined the role of neuroimaging in the setting of autoimmune encephalitides, comparing the utility of 18 F-FDG PET/CT versus conventional brain imaging with MRI. Methods: A retrospective study was performed assessing the positivity rate of MRI versus 18 F-FDG PET/CT during the initial workup of 23 patients proven to have antibody-positive autoimmune encephalitis. 18 F-FDG PET/CT studies were analyzed both qualitatively and semiquantitatively. Areas of cortical lobar hypo (hyper)-metabolism in the cerebrum that were 2 SDx from the mean were recorded as abnormal. Results: On visual inspection, all patients were identified as having an abnormal pattern of 18 F-FDG uptake. In semiquantitative analysis, at least 1 region of interest with metabolic change was identified in 22 of 23 (95.6%) patients using a discriminating z score of 2. Overall, 18 F-FDG PET/CT was more often abnormal during the diagnostic period than MRI (10/23, 43% of patients). The predominant finding on brain 18 F-FDG PET/CT imaging was lobar hypometabolism, being observed in 21 of 23 (91.3%) patients. Hypometabolism was most commonly observed in the parietal lobe followed by the occipital lobe. An entire subset of antibody-positive patients, anti- N -methyl-d-aspartate receptor (5 patients), had normal MRI results and abnormal 18 F-FDG PET/CT findings whereas the other subsets demonstrated a greater heterogeneity. Conclusion: Brain 18 F-FDG PET/CT may play a significant role in the initial evaluation of patients with clinically suspected antibody-mediated autoimmune encephalitis. Given that it is more often abnormal when compared with MRI in the acute setting, this molecular imaging technique may be better positioned as an early biomarker of disease so that treatment may be initiated earlier, resulting in improved patient

  8. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    PubMed

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    hernias. Comparison CT of the 28 patients with a hiatal hernia at CTC showed the absence of the hernia in 57.1 % (16/28) patients, including 68.8 % (11/16) and 50 % (5/10) of small and moderate hernias. The prevalence of sliding hiatal hernias in the external control group was 22 % (44/200), significantly lower than the CT-WE and CTC cohorts' prevalence of 51 % (p < 0.0001) and 48.5 % (p < 0.0001). After applying the correction factors for the CT-WE and the CTC groups, the estimated residual prevalences (16 and 18.5 %, respectively) were much closer to that of the external control patients (p = 0.160 for CT-WE and p = 0.455 for CTC). We believe that incidental findings at CT-WE and CTC should be considered according to the clinical background, and that small sliding hiatal hernias should not be reported in patients with symptoms not related to reflux disease undergoing CT-WE or CTC: When encountering these findings, accurate anamnesis and review of medical history looking for GERD-related symptoms are essential, in order to address these patients to a correct diagnostic iter, taking advantage from more appropriate techniques such as endoscopy or functional techniques.

  9. Using Helical CT to Predict Stone Fragility in Shock Wave Lithotripsy (SWL)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, James C. Jr.; Zarse, Chad A.; Jackson, Molly E.

    2007-04-05

    Great variability exists in the response of urinary stones to SWL, and this is true even for stones composed of the same mineral. Efforts have been made to predict stone fragility to shock waves using computed tomography (CT) patient images, but most work to date has focused on the use of stone CT number (i.e., Hounsfield units). This is an easy number to measure on a patient stone, but its value depends on a number of factors, including the relationship of the size of the stone to me resolution (i.e., the slicewidth) of the CT scan. Studies that have shownmore » a relationship between stone CT number and failure in SWL are reviewed, and all are shown to suffer from error due to stone size, which was not accounted for in the use of Hounsfield unit values. Preliminary data are then presented for a study of calcium oxalate monohydrate (COM) stones, in which stone structure-rather than simple CT number values-is shown to correlate with fragility to shock waves. COM stones that were observed to have structure by micro CT (e.g., voids, apatite regions, unusual shapes) broke to completion in about half the number of shock waves required for COM stones that were observed to be homogeneous in structure by CT. This result suggests another direction for the use of CT in predicting success of SWL: the use of CT to view stone structure, rather than simply measuring stone CT number. Viewing stone structure by CT requires the use of different viewing windows than those typically used for examining patient scans, but much research to date indicates that stone structure can be observed in the clinical setting. Future clinical studies will need to be done to verify the relationship between stone structure observed by CT and stone fragility in SWL.« less

  10. Can clinical CT data improve forensic reconstruction?

    PubMed

    Schuh, P; Scheurer, E; Fritz, K; Pavlic, M; Hassler, E; Rienmüller, R; Yen, K

    2013-05-01

    In accidents resulting in severe injuries, a clinical forensic examination is generally abandoned in the initial phase due to high-priority clinical needs. However, in many cases, data from clinical computed tomography (CT) examinations are available. The goals of this prospective study were (a) to evaluate clinical CT data as a basis for forensic reconstruction of the sequence of events, (b) to assess if forensic radiological follow-up reading improves the forensic diagnostic benefit compared to the written clinical radiological reports, and (c) to evaluate if full data storage including additional reconstructed 0.6-mm slices enhances forensic analysis. Clinical CT data of 15 living individuals with imaging of at least the head, thorax, and abdomen following polytrauma were examined regarding the forensic evaluation of the sequence of events. Additionally, 0.6-mm slices and 3D images were reconstructed for forensic purposes and used for the evaluation. At the forensic radiological readings, additional traumatic findings were observed in ten of the 15 patients. The main weakness of the clinical reports was that they were not detailed enough, particularly regarding the localization of injuries and description of wound morphology. In seven cases, however, forensic conclusions were possible on the basis of the written clinical reports, whereas in five cases forensic reconstruction required specific follow-up reading. The additional 0.6-mm slices were easily available and with improved 3D image quality and forensic diagnostics. In conclusion, the use of clinical CT data can considerably support forensic expertise regarding reconstruction issues. Forensic follow-up reading as well as the use of additional thin slices for 3D analysis can further improve its benefit for forensic reconstruction purposes.

  11. Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector.

    PubMed

    Liu, Yu; Leng, Shuai; Michalak, Gregory J; Vrieze, Thomas J; Duan, Xinhui; Qu, Mingliang; Shiung, Maria M; McCollough, Cynthia H; Fletcher, Joel G

    2014-01-01

    To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P < 0.001), image noise was significantly lower (both P < 0.001), whereas volume CT dose index was unchanged (both P > 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.

  12. Limited utility of MRA for acute bowel ischemia after portal venous phase CT.

    PubMed

    Shetty, Anup S; Mellnick, Vincent M; Raptis, Constantine; Loch, Ronald; Owen, Joseph; Bhalla, Sanjeev

    2015-10-01

    Mesenteric ischemia and ischemic colitis are uncommon but potentially life-threatening causes of acute abdominal pain. Portal venous phase computed tomography (CT) is routinely ordered in the emergency room setting for abdominal pain, but subsequent MR angiography may be requested for additional evaluation of the mesenteric vasculature. We compare the concordance of CT and magnetic resonance angiography (MRA) for acute bowel ischemia. Thirty-two patients who underwent contrast-enhanced MRA for bowel ischemia after having undergone CT evaluation within the preceding 2 weeks were identified. A retrospective review of imaging, treatment history, surgical, and pathology reports was conducted. Two radiologists each reviewed the imaging studies in a blinded fashion. Ten cases of bowel ischemia were confirmed by endoscopy and/or surgical pathology. CT correctly identified bowel findings in all cases. Intraobserver agreement between CT and MRA for all vessels was 0.68 and 0.63, highest for the superior mesenteric artery. Interobserver agreement was 0.74 for MRA and 0.78 for CT. Vascular findings were only directly mentioned in 10 of 32 CT reports (and 7 of 10 cases with confirmed bowel ischemia). MRA only detected two additional or alternative diagnoses. Portal venous phase CT and MRA demonstrate a high degree of concordance for vascular evaluation. Reviewed CT examinations were sufficient to assess the patency of the mesenteric vasculature, but vascular findings were not reported in most cases. A direct description within the report may have obviated the request for further MR imaging. MRA adds little value after portal venous CT in assessing bowel ischemia.

  13. Accurate CT-MR image registration for deep brain stimulation: a multi-observer evaluation study

    NASA Astrophysics Data System (ADS)

    Rühaak, Jan; Derksen, Alexander; Heldmann, Stefan; Hallmann, Marc; Meine, Hans

    2015-03-01

    Since the first clinical interventions in the late 1980s, Deep Brain Stimulation (DBS) of the subthalamic nucleus has evolved into a very effective treatment option for patients with severe Parkinson's disease. DBS entails the implantation of an electrode that performs high frequency stimulations to a target area deep inside the brain. A very accurate placement of the electrode is a prerequisite for positive therapy outcome. The assessment of the intervention result is of central importance in DBS treatment and involves the registration of pre- and postinterventional scans. In this paper, we present an image processing pipeline for highly accurate registration of postoperative CT to preoperative MR. Our method consists of two steps: a fully automatic pre-alignment using a detection of the skull tip in the CT based on fuzzy connectedness, and an intensity-based rigid registration. The registration uses the Normalized Gradient Fields distance measure in a multilevel Gauss-Newton optimization framework and focuses on a region around the subthalamic nucleus in the MR. The accuracy of our method was extensively evaluated on 20 DBS datasets from clinical routine and compared with manual expert registrations. For each dataset, three independent registrations were available, thus allowing to relate algorithmic with expert performance. Our method achieved an average registration error of 0.95mm in the target region around the subthalamic nucleus as compared to an inter-observer variability of 1.12 mm. Together with the short registration time of about five seconds on average, our method forms a very attractive package that can be considered ready for clinical use.

  14. Comparison Between 64Cu-PSMA-617 PET/CT and 18F-Choline PET/CT Imaging in Early Diagnosis of Prostate Cancer Biochemical Recurrence.

    PubMed

    Cantiello, Francesco; Crocerossa, Fabio; Russo, Giorgio Ivan; Gangemi, Vincenzo; Ferro, Matteo; Vartolomei, Mihai Dorin; Lucarelli, Giuseppe; Mirabelli, Maria; Scafuro, Chiara; Ucciero, Giuseppe; De Cobelli, Ottavio; Morgia, Giuseppe; Damiano, Rocco; Cascini, Giuseppe Lucio

    2018-06-04

    To evaluate the diagnostic performance of 64 Cu-PSMA-617 positron emission tomography (PET) with computed tomography (CT) for restaging prostate cancer after biochemical recurrence (BCR) and to compare it with 18 F-choline PET/CT in a per-patient analysis. An observational study was performed of 43 patients with BCR after laparoscopic radical prostatectomy who underwent 64 Cu-PSMA-617 PET/CT and subsequently 18 F-choline PET/CT for restaging. The detection rates (DR) of 64 Cu-PSMA-617 PET/CT and of 18 F-choline PET/CT were calculated by standardized maximum uptake value (SUV max ) at 4 hours and SUV max at 1 hour as reference, respectively. Furthermore, univariate logistic regression analysis was carried out to identify independent predictive factors of positivity with 64 Cu-PSMA-617 PET/CT. An overall positivity with 64 Cu-PSMA-617 PET/CT was found in 32 patients (74.4%) versus 19 (44.2%) with 18 F-choline PET/CT. Specifically, after stratifying for prostate-specific antigen (PSA) values, we found a good performance of 64 Cu-PSMA-617 PET/CT at low PSA levels compared to 18 F-choline PET/CT, with a DR of 57.1% versus 14.3% for PSA 0.2-0.5 ng/mL (P = .031), and of 60% versus 30% with PSA 0.5-1 ng/mL. At univariate binary logistic regression analysis, PSA level was the only independent predictor of 64 Cu-PSMA-617 PET/CT positivity. No significant difference in terms of DR for both 64 Cu-PSMA-617 PET/CT and 18 F-choline PET/CT was found according to different Gleason score subgroups. In our study cohort, a better performance was observed for 64 Cu-PSMA-617 PET/CT compared to 18 F-choline PET/CT in restaging after BCR, especially in patients with low PSA values. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. CT in the diagnosis of enterovesical fistulae

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldman, S.M.; Fishman, E.K.; Gatewood, O.M.B.

    1985-06-01

    Enterovesical fistulae are difficult to demonstrate by conventional radiographic methods. Computed tomography (CT), a sensitive, noninvasive method of documenting the presence of such fistulae, is unique in its ability to outline the extravesical component of the primary disease process. Twenty enterovesical fistulae identified by CT were caused by diverticulitis (nine), carcinoma of the rectosigmoid (two), Crohn disease (three), gynecologic tumors (two), bladder cancer (one), cecal carcinoma (one), prostatic neoplasia (one), and appendiceal abscess (one). The CT findings included intravesical air (90%), passage of orally or rectally administered contrast medium into the bladder (20%), focal bladder-wall thickening (90%), thickening of adjacentmore » bowel wall (85%), and an extraluminal mass that often contained air (75%). CT proved to be an important new method in the diagnosis of enterovesical fistulae.« less

  16. Neurocognitive assessment in patients with a minor traumatic brain injury and an abnormal initial CT scan: Can cognitive evaluation assist in identifying patients who require surveillance CT brain imaging?

    PubMed

    Clements, Thomas W; Dunham, Michael; Kirkpatrick, Andrew; Rajakumar, Ruphus; Gratton, Carolyn; Lall, Rohan; McBeth, Paul; Ball, Chad G

    2018-05-01

    Evidence for repeat computed tomography (CT) in minor traumatic brain injury (mTBI) patients with intracranial pathology is scarce. The aim of this study was to investigate the utility of clinical cognitive assessment (COG) in defining the need for repeat imaging. COG performance was compared with findings on subsequent CT, and need for neurosurgery in mTBI patients (GCS 13-15 and positive CT findings). Of 152 patients, 65.8% received a COG (53.0% passed). Patients with passed COG underwent fewer repeat CT (43.4% vs. 78.7%; p = .001) and had shorter LOS (8.7 vs. 19.5; p < .05). Only 1 patient required neurosurgery after a passed COG. The negative predictive value of a normal COG was 90.6% (95%CI = 81.8%-95.4%). mTBI patients with an abnormal index CT who pass COG are less likely to undergo repeat CT head, and rarely require neurosurgery. The COG warrants further investigation to determine its role in omitting repeat head CT. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Haustral fold registration in CT colonography and its application to registration of virtual stretched view of the colon

    NASA Astrophysics Data System (ADS)

    Fukano, Eiichiro; Oda, Masahiro; Kitasaka, Takayuki; Suenaga, Yasuhito; Takayama, Tetsuji; Takabatake, Hirotsugu; Mori, Masaki; Natori, Hiroshi; Nawano, Shigeru; Mori, Kensaku

    2010-03-01

    This paper proposes a method for making correspondence between the supine and the prone positions of the colon in CT volumes. In CT colonography, two CT volumes in the supine and the prone positions are often taken to observe the whole colonic wall by comparing them. However, the colonic wall is soft and changes its shape when a patient changes positions. Therefore, physicians need to take the positional relations into account when comparing the two CT volumes. Calculation of the positional relations between the two positions of the colon can reduce load of physicians. A large number of haustral folds exists in the colon and the order doesn't change even when a patient change positions. Therefore, haustral folds are suitable for registering the supine and the prone positions of the colon. We also find sharply bending points of the centerline of the colon as landmarks for brief registration. The precise registration is then performed by finding positional correspondence of the haustral folds in the supine and the prone positions. In correspondence search, we first find the correspondence among long haustral folds, followed by small haustral folds. As the result of experiment using six pairs of 3D abdominal CT volumes, 65.1% of the correspondence of large haustral folds were correct, 25.6% were incorrect, and 9.3% could not be judged. On the other hand, 13.3% of the correspondence of small haustral folds were correct, 42.9% were incorrect, and 32.7% could not be judged.

  18. Accuracy of limited four-slice CT-scan in diagnosis of chronic rhinosinusitis.

    PubMed

    Zojaji, R; Nekooei, S; Naghibi, S; Mazloum Farsi Baf, M; Jalilian, R; Masoomi, M

    2015-12-01

    Chronic rhinosinusitis (CRS) is a common chronic health condition worldwide. Standard CT-scan is the method of choice for diagnosis of CRS but its high price and considerable radiation exposure have limited its application. The main goal of this study was to evaluate the accuracy of limited four-slice coronal CT-scan in the diagnosis of CRS. This cross-sectional study was conducted on 46 patients with CRS, for one year, based on American Society of Head and Neck Surgery criteria. All patients received the preoperative standard and four-slice CT-scans, after which endoscopic sinus surgery was performed. Findings of four-slice CT-scans were compared with those of conventional CT-scan and the sensitivity and specificity of four-slice CT-scan and its agreement with conventional CT-scan was calculated. In this study, 46 patients including 32 males (69.6%) and 14 females (30.46%) with a mean age of 33 and standard deviation of 9 years, were evaluated. Sensitivity and specificity of four-slice CT-scan were 97.5% and 100%, respectively. Also, positive predictive value (PPV) and negative predictive value (NPV) of four-slice CT was 100% and 85.71%, respectively. There was a strong agreement between four-slice CT and conventional CT findings. Considering the high sensitivity and specificity of four-slice CT-scan and strong agreement with conventional CT-scan in the diagnosis of CRS and the lower radiation exposure and cost, application of this method is suggested for both diagnosis and treatment follow-up in CRS. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. (18)F-FDG PET-CT simulation for non-small-cell lung cancer: effect in patients already staged by PET-CT.

    PubMed

    Hanna, Gerard G; McAleese, Jonathan; Carson, Kathryn J; Stewart, David P; Cosgrove, Vivian P; Eakin, Ruth L; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H; Young, V A Linda; O'Sullivan, Joe M; Hounsell, Alan R

    2010-05-01

    Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV(CT) to GTV(FUSED) was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

  20. Colonoscopic Findings in Patients With Incidental Colonic Focal FDG Uptake.

    PubMed

    Keyzer, Caroline; Dhaene, Benjamin; Blocklet, Didier; De Maertelaer, Viviane; Goldman, Serge; Gevenois, Pierre Alain

    2015-05-01

    The purpose of this study was to investigate the nature of FDG-avid and non-FDG-avid lesions detected at colonoscopy in patients presenting with incidental focal colonic FDG uptake at PET/CT. Among 9073 patients who underwent PET/CT over a 4-year period, 82 patients without a history of colonic disease had focal colonic FDG uptake and underwent colonoscopy. In consensus, a radiologist and a nuclear physician read images from these PET/CT examinations. They recorded the location of focal FDG uptake in the colon and associated CT abnormalities and measured maximum standardized uptake value (SUVmax) and metabolic volume (MV). Readings were performed twice--first without and second with knowledge of lesion location at colonoscopy. The final diagnosis was based on colonoscopic findings and histopathologic results categorized into benign, premalignant, or malignant. One hundred seven foci of colonic FDG uptake at PET/CT and 150 lesions at colonoscopy were detected. Among 107 foci of FDG uptake, 65 (61%) corresponded to a lesion at colonoscopy (true-positive findings), and 42 (39%) did not (false-positive findings). Among 150 lesions found at colonoscopy, 85 (57%) were not FDG avid (false-negative findings). The MV of true-positive findings was lower than that of false-positive findings (4.0 ± 0.4 cm(3) vs 6.2 ± 0.7 cm(3); p = 0.006), but SUVmax did not differ (7.4 ± 0.5 vs 7.7 ± 0.5; p = 0.649). Considering the histopathologic categories of the lesions and the false-positive findings, there was no difference in SUVmax (p = 0.103), but MV was lower in premalignant lesions than in false-positive findings (p = 0.005). Focal colonic FDG uptake may indicate the presence of a benign, pre-malignant, or malignant lesion. Subsequent colonoscopy should not be restricted to the colonic site of FDG uptake.

  1. Diagnosis of Grave's disease with pulmonary hypertension on chest CT.

    PubMed

    Lee, Hwa Yeon; Yoo, Seung Min; Kim, Hye Rin; Chun, Eun Ju; White, Charles S

    To evaluate the diagnostic accuracy of chest CT findings to diagnose Grave's disease in pulmonary hypertension. We retrospectively evaluated chest CT and the medical records of 13 patients with Grave's disease with (n=6) or without pulmonary hypertension (n=7) and in 17 control patients. Presence of iso-attenuation of diffusely enlarged thyroid glands compared with adjacent neck muscle on non-enhanced CT as a diagnostic clue of Grave's disease, and assessment of pulmonary hypertension on CT has high diagnostic accuracy. Chest CT has the potential to diagnose Grave's disease with pulmonary hypertension in the absence of other information. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Radiographic, computed tomographic, gross pathological and histological findings with suspected apical infection in 32 equine maxillary cheek teeth (2012-2015).

    PubMed

    Liuti, T; Smith, S; Dixon, P M

    2018-01-01

    Equine maxillary cheek teeth apical infections are a significant disorder because of frequent spread of infection to the supporting bones. The accuracy of computed tomographic imaging (CT) of this disorder has not been fully assessed. To compare the radiographic and CT findings in horses diagnosed with maxillary cheek teeth apical infections with pathological findings in the extracted teeth to assess the accuracy of these imaging techniques. Observational clinical study. Thirty-two maxillary cheek teeth (in 29 horses) diagnosed with apical infections by clinical, radiographic and principally by CT examinations, were extracted orally. The extracted teeth were subjected to further CT, gross pathological and histological examinations. Four normal teeth extracted from a cadaver served as controls. Pulpar and apical changes highly indicative of maxillary cheek teeth apical infection were present in all 32 teeth on CT, but in just 17/32 teeth (53%) radiographically. Gross pulpar/apical abnormalities and histological pulpar/periapical changes were present in 31/32 (97%) extracted teeth. On CT, one tooth contained small gas pockets in the apical aspect of one pulp and adjacent periodontal space, however no pathological changes were found following its extraction. The study is descriptive and is confined to a small number of cases. This study showed a 97% agreement between CT diagnosis of maxillary cheek teeth apical infection and the presence of pathological changes in the extracted teeth, confirming the diagnostic accuracy of CT compared with radiography for this disorder. © 2017 EVJ Ltd.

  3. Computed tomographic findings of cerebral fat embolism following multiple bone fractures.

    PubMed

    Law, Huong Ling; Wong, Siong Lung; Tan, Suzet

    2013-02-01

    Fat embolism to the lungs and brain is an uncommon complication following fractures. Few reports with descriptions of computed tomographic (CT) findings of emboli to the brain or cerebral fat embolism are available. We report a case of cerebral fat embolism following multiple skeletal fractures and present its CT findings here.

  4. How accurate is unenhanced multidetector-row CT (MDCT) for localization of renal calculi?

    PubMed

    Goetschi, Stefan; Umbehr, Martin; Ullrich, Stephan; Glenck, Michael; Suter, Stefan; Weishaupt, Dominik

    2012-11-01

    To investigate the correlation between unenhanced MDCT and intraoperative findings with regard to the exact anatomical location of renal calculi. Fifty-nine patients who underwent unenhanced MDCT for suspected urinary stone disease, and who underwent subsequent flexible ureterorenoscopy (URS) as treatment of nephrolithiasis were included in this retrospective study. All MDCT data sets were independently reviewed by three observers with different degrees of experience in reading CT. Each observer was asked to indicate presence and exact anatomical location of any calcification within pyelocaliceal system, renal papilla or renal cortex. Results were compared to intraoperative findings which have been defined as standard of reference. Calculi not described at surgery, but present on MDCT data were counted as renal cortex calcifications. Overall 166 calculi in 59 kidneys have been detected on MDCT, 100 (60.2%) were located in the pyelocaliceal system and 66 (39.8%) in the renal parenchyma. Of the 100 pyelocaliceal calculi, 84 (84%) were correctly located on CT data sets by observer 1, 62 (62%) by observer 2, and 71 (71%) by observer 3. Sensitivity/specificity was 90-94% and 50-100% if only pyelocaliceal calculi measuring >4 mm in size were considered. For pyelocaliceal calculi≤4 mm in size diagnostic performance of MDCT was inferior. Compared to flexible URS, unenhanced MDCT is accurate for distinction between pyelocaliceal calculi and renal parenchyma calcifications if renal calculi are >4 mm in size. For smaller renal calculi, unenhanced MDCT is less accurate and distinction between a pyelocaliceal calculus and renal parenchyma calcification is difficult. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Diagnostic test accuracy study of 18F-sodium fluoride PET/CT, 99mTc-labelled diphosphonate SPECT/CT, and planar bone scintigraphy for diagnosis of bone metastases in newly diagnosed, high-risk prostate cancer

    PubMed Central

    Fonager, Randi F; Zacho, Helle D; Langkilde, Niels C; Fledelius, Joan; Ejlersen, June A; Haarmark, Christian; Hendel, Helle W; Lange, Mine Benedicte; Jochumsen, Mads R; Mortensen, Jesper C; Petersen, Lars J

    2017-01-01

    The aim of this study was to prospectively compare planar, bone scan (BS) versus SPECT/CT and NaF PET/CT in detecting bone metastases in prostate cancer. Thirty-seven consecutive, newly diagnosed, prostate cancer patients with prostate specific antigen (PSA) levels ≥ 50 ng/mL and who were considered eligible for androgen-deprivation therapy (ADT) were included in this study. BS, SPECT/CT, and NaF PET/CT, were performed prior to treatment and were repeated after six months of ADT. Baseline images from each index test were independently read by two experienced readers. The reference standard was based on a consensus decision made by a multidisciplinary team on the basis of baseline and follow-up images of the index tests, the findings of the baseline index tests by the experienced readers, and any available imaging, biochemical, and clinical data, including the response to ADT. Twenty-seven (73%) of the 37 patients had bone metastases according to the reference standard. The sensitivities for BS, SPECT/CT and NaF PET/CT were 78%, 89%, and 89%, respectively, and the specificities were 90%, 100%, and 90%, respectively. The positive predictive values of BS, SPECT/CT and NaF PET/CT were 96%, 100%, and 96%, respectively, and the negative predictive values were 60%, 77% and 75%, respectively. No statistically significant difference among the three imaging modalities was observed. All three imaging modalities showed high sensitivity and specificity. NaF PET/CT and SPECT/CT showed numerically improved, but not statistically superior, sensitivity compared with BS in this limited and selected patient cohort. PMID:29181269

  6. Differential diagnosis of primary nasopharyngeal lymphoma and nasopharyngeal carcinoma focusing on CT, MRI, and PET/CT.

    PubMed

    Cho, Kyu-Sup; Kang, Dae-Woon; Kim, Hak-Jin; Lee, Jong-Kil; Roh, Hwan-Jung

    2012-04-01

    No study has done a comparative analysis of radiologic imaging findings between primary nasopharyngeal lymphoma (PNL) and nasopharyngeal carcinoma (NPC). The purpose of this study was to analyze computed tomography (CT) and magnetic resonance (MR) images and to evaluate the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/CT between PNL and NPC, knowing the imaging features that distinguish PNL from NPC. Cross-sectional study. University tertiary care facility. The authors analyzed the features on CT, MR imaging, and PET/CT of 16 patients diagnosed with PNL and 32 patients diagnosed with NPC histopathologically. Patients with PNL had a larger tumor volume and showed symmetry of tumor shape than did patients with NPC. Patients with PNL also had higher tumor homogeneity than NPC patients on CT, T2-weighted, and postcontrast MR images. All PNL patients showed a high degree of enhancement without invasion to the adjacent deep structure. The involvement of the Waldeyer ring was significantly higher in PNL patients. Cervical and retropharyngeal lymphadenopathy and PET/CT SUV max showed no significant difference between PNL and NPC. If the images present a bulky, symmetric nasopharyngeal mass with marked homogeneity, a high degree of enhancement, and a higher Waldeyer ring involvement combined with no invasion into the deep structure, PNL should be considered over NPC.

  7. The diagnostic challenge of the sequelae of acute pancreatitis on CT imaging: a pictorial essay.

    PubMed

    Hughey, Mark; Taffel, Myles; Zeman, Robert K; Patel, Smita; Hill, Michael C

    2017-04-01

    The purpose of the study was to present a pictorial review of the long-term sequelae of acute pancreatitis on CT imaging as these findings can cause diagnostic confusion in the absence of a proper clinical history and/or prior CT imaging. We retrospectively identified 81 patients who had an episode of acute pancreatitis with diagnostic findings on CT and also underwent one or more follow-up CT scans at least 1 month beyond the acute episode. The residual findings on all follow-up CT scans were tabulated, including the time interval since the initial bout of acute pancreatitis. Residual inflammatory changes were present in 19.8% of cases, with a median time period lasting 86 days since the initial episode of acute pancreatitis. Residual fluid collections were seen in 27.2% and persisted for a median of 132 days. Three patients had residual solid-appearing inflammatory masses, which could be mistaken for neoplasms. Other long-term sequelae were also tabulated, including pancreatic ductal dilatation, pancreatic atrophy, new or increased pancreatic calcifications, biliary tract dilatation, central portal venous occlusion, and pseudoaneurysm formation. These residual findings and long-term complications are presented as a pictorial essay. Recognizing the spectrum of residual findings of acute pancreatitis, some of which can be long term, is important in the correct interpretation of a pancreatic CT. These findings can mimic acute pancreatitis or a pancreatic/peripancreatic neoplasm and often cause diagnostic confusion, especially in the absence of prior CT imaging.

  8. Ultrasonography and contrast-enhanced CT findings of tularemia in the neck.

    PubMed

    Doğan, Serap; Ekinci, Afra; Demiraslan, Hayati; Ulu Kılıç, Ayşegül; Mavili, Ertuğrul; Öztürk, Mustafa; İmamoğlu, Hakan; Doğanay, Mehmet

    2016-01-01

    We aimed to evaluate the ultrasonography (US) and contrast-enhanced computed tomography (CECT) findings of tularemia in the neck. US and CECT findings of 58 patients with serologically proven tularemia were retrospectively evaluated. Forty-eight patients underwent US and 42 patients underwent CECT. Lymph node characteristics and parotid preauricular region involvement were analyzed using US and CECT. In addition, involvement of larynx, oropharynx, and retropharynx; presence of periorbital edema; and neck abscess formation were evaluated using CECT. Fine needle aspiration cytology (FNAC) results of enlarged lymph nodes were analyzed in 29 patients. Hypoechoic pattern, round shape, absence of hilum, and cystic necrosis were seen in most of the lymph nodes especially at level 2 and 3 on US and CECT. Matting was more commonly observed than irregular nodal border on US and CECT. Parotid preauricular region involvement was seen in 20.8% of patients on US. Oropharyngeal, retropharyngeal, laryngeal and parotid preauricular region involvement and periorbital edema were seen in 52.4%, 19.1%, 4.8%, 31%, and 9.5% of tularemia patients, respectively. Neck abscess was found in 59.5% of patients on CECT. Suppurative inflammation was the most common finding of FNAC. Tularemia should be considered in the presence of level 2 and 3 lymph nodes with cystic necrosis, matting, absence of calcification, oropharyngeal and retropharyngeal region involvement, and neck abscess, particularly in endemic areas.

  9. Additional value of hybrid SPECT/CT systems in neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas.

    PubMed

    Wong, K K; Chondrogiannis, S; Fuster, D; Ruiz, C; Marzola, M C; Giammarile, F; Colletti, P M; Rubello, D

    The aim of this review was to evaluate the potential advantages of SPECT/CT hybrid imaging in the management of neuroendocrine tumors, adrenal tumors, pheochromocytomas and paragangliomas. From the collected data, the superiority of fused images was observed as providing both functional/molecular and morphological imaging compared to planar imaging. This provided an improvement in diagnostic imaging, with significant advantages as regards: (1) precise locating of the lesions; (2) an improvement in characterization of the findings, resulting higher specificity, improved sensitivity, and overall greater accuracy, (3) additional anatomical information derived from the CT component; (4) CT-based attenuation correction and potential for volumetric dosimetry calculations, and (5) improvement on the impact on patient management (e.g. in better defining treatment plans, in shortening surgical operating times). It can be concluded that SPECT/CT hybrid imaging provides the nuclear medicine physician with a powerful imaging modality in comparison to planar imaging, providing essential information about the location of lesions, and high quality homogeneous images. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  10. Low contrast detection in abdominal CT: comparing single-slice and multi-slice tasks

    NASA Astrophysics Data System (ADS)

    Ba, Alexandre; Racine, Damien; Viry, Anaïs.; Verdun, Francis R.; Schmidt, Sabine; Bochud, François O.

    2017-03-01

    Image quality assessment is crucial for the optimization of computed tomography (CT) protocols. Human and mathematical model observers are increasingly used for the detection of low contrast signal in abdominal CT, but are frequently limited to the use of a single image slice. Another limitation is that most of them only consider the detection of a signal embedded in a uniform background phantom. The purpose of this paper was to test if human observer performance is significantly different in CT images read in single or multiple slice modes and if these differences are the same for anatomical and uniform clinical images. We investigated detection performance and scrolling trends of human observers of a simulated liver lesion embedded in anatomical and uniform CT backgrounds. Results show that observers don't take significantly benefit of additional information provided in multi-slice reading mode. Regarding the background, performances are moderately higher for uniform than for anatomical images. Our results suggest that for low contrast detection in abdominal CT, the use of multi-slice model observers would probably only add a marginal benefit. On the other hand, the quality of a CT image is more accurately estimated with clinical anatomical backgrounds.

  11. Atrophic inferior vena cava is a marker of chronicity of intra-filter and inferior vena cava thrombosis: based on CT findings.

    PubMed

    Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng

    2018-04-11

    A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.

  12. SpaceWire Tiger Team Findings and Suggestions

    NASA Technical Reports Server (NTRS)

    Ishac, Joseph A.

    2011-01-01

    This technical report intends to highlight the key findings and recommendations of the SpaceWire Tiger Team for the CoNNeCT project. It covers findings which are technical in nature, covering design concepts and approaches.

  13. CT findings of descending necrotising mediastinitis via the carotid space ('Lincoln Highway').

    PubMed

    Kono, T; Kohno, A; Kuwashima, S; Iimura, F; Fujioka, M; Miyata, R; Mizusawa, Y; Kagawa, F; Kaneko, S; Yoshino, Y; Misawa, M; Ito, M; Otsuka, M; Seki, I

    2001-02-01

    A 3-year-old girl with fever and neck swelling showed widening of the superior mediastinum on chest radiographs. Contrast-enhanced CT of the neck revealed ill-defined low-attenuation areas with a thick, enhanced rim adjacent to the hypertrophied palatine tonsil. The abscess extended inferiorly within the carotid sheath between the carotid artery and the internal jugular vein into the anterior mediastinum. The carotid space is considered an important conduit of descending necrotising mediastinitis and is called the 'Lincoln Highway' as previously suggested.

  14. Brain CT image similarity retrieval method based on uncertain location graph.

    PubMed

    Pan, Haiwei; Li, Pengyuan; Li, Qing; Han, Qilong; Feng, Xiaoning; Gao, Linlin

    2014-03-01

    A number of brain computed tomography (CT) images stored in hospitals that contain valuable information should be shared to support computer-aided diagnosis systems. Finding the similar brain CT images from the brain CT image database can effectively help doctors diagnose based on the earlier cases. However, the similarity retrieval for brain CT images requires much higher accuracy than the general images. In this paper, a new model of uncertain location graph (ULG) is presented for brain CT image modeling and similarity retrieval. According to the characteristics of brain CT image, we propose a novel method to model brain CT image to ULG based on brain CT image texture. Then, a scheme for ULG similarity retrieval is introduced. Furthermore, an effective index structure is applied to reduce the searching time. Experimental results reveal that our method functions well on brain CT images similarity retrieval with higher accuracy and efficiency.

  15. Imaging Findings of Isolated Bronchial Anthracofibrosis: A Computed Tomography Analysis of Patients With Bronchoscopic and Histologic Confirmation.

    PubMed

    Kahkouee, Shahram; Pourghorban, Ramin; Bitarafan, Mahdi; Najafizadeh, Katayoun; Makki, Seyed Shahabeddin Mohammad

    2015-07-01

    To evaluate the chest computed tomography (CT) findings of patients with isolated bronchial anthracofibrosis confirmed by bronchoscopy and histopathology. Fifty-eight patients with isolated bronchial anthracofibrosis (29 females; mean age, 70 years) were enrolled in this study. The diagnosis of bronchial anthracofibrosis was made based on both bronchoscopy and pathology findings in all patients. The various chest CT images were retrospectively reviewed by two chest radiologists who reached decisions in consensus. Central peribronchial soft tissue thickening (n=37, 63.8%) causing bronchial narrowing (n=37, 63.8%) or obstruction (n=11, 19%) was identified as an important finding on imaging. Multiple bronchial stenoses with concurrent involvement of 2, 3, and 5 bronchi were seen in 12 (21%), 9 (15%), and 2 (3.4%) patients, respectively. Segmental atelectasis and lobar or multilobar collapse were detected. These findings mostly occurred in the right lung, predominantly in the right middle lobe. Mosaic attenuation patterns, scattered parenchymal nodules, nodular patterns, and calcified or non-calcified lymph nodes were also observed. On chest CT, isolated bronchial anthracofibrosis appeared as peribronchial soft tissue thickening, bronchial narrowing or obstruction, segmental atelectasis, and lobar or multilobar collapse. The findings were more common in the right side, with simultaneous involvement of multiple bronchi in some patients. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  16. CT differentiation of 1-2-cm gallbladder polyps: benign vs malignant.

    PubMed

    Song, E Rang; Chung, Woo-Suk; Jang, Hye Young; Yoon, Minjae; Cha, Eun Jung

    2014-04-01

    To evaluate MDCT findings of 1-2-cm sized gallbladder (GB) polyps for differentiation between benign and malignant polyps. Institutional review board approval was obtained, and informed consent was waived. Portal venous phase CT scans of 1-2-cm sized GB polyps caused by various pathologic conditions were retrospectively reviewed by two blinded observers. Among the 36 patients identified, 21 had benign polyps with the remaining 15 having malignant polyps. Size, margin, and shape of GB polyps were evaluated. Attenuation values of the polyps, including mean attenuation, maximum attenuation, and standard deviation, were recorded. As determined by visual inspection, the degree of polyp enhancement was evaluated. Using these CT findings, each of the two radiologists assessed and recorded individual diagnostic confidence for differentiating benign versus malignant polyps on a 5-point scale. The diagnostic performance of CT was evaluated using a receiver operating characteristic curve analysis. There was no significant difference in size between benign and malignant GB polyps. Ill-defined margin and sessile morphology were significantly associated with malignant polyp. There was a significant difference in mean and maximum attenuation values between benign and malignant GB polyps. Mean standard deviation value of malignant polyps was significantly higher than that of benign polyps. All malignant polyps showed either hyperenhancement or marked hyperenhancement. A z value for the diagnosis of malignant GB polyps was 0.905. Margin, shape, and enhancement degree are helpful in differentiating between benign and malignant polyps of 1-2-cm sizes.

  17. Focal hepatic fatty infiltration in the posterior edge of the medial segment associated with aberrant gastric venous drainage: CT, US, and MR findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawamori, Yashuiro; Matsui, Osamu; Takahashi, S.

    1996-05-01

    The purpose of this study is to demonstrate the relation between focal hepatic fatty infiltration and aberrant gastric venous drainage (AGVD) in the posterior edge of the medial segment (PEMS) of the liver and we present two cases of focal hepatic fatty infiltration with AGVD in the PEMS and discuss their imaging features. In both cases the focal fatty infiltration areas were hyperechoic on sonography, hypodense on CT, and hyperintense on T1-weighted MRI. Computed tomography during arterial portography (CTAP) showed nodular perfusion defects corresponding to the areas in both cases, and early enhancement of the area was observed with dynamicmore » MRI in one case. Although the findings on CTAP and dynamic MRI suggested a neoplastic nature for the lesions, focal fatty infiltration was confirmed with surgical resection in one case and with imaging follow-up in the other. Aberrant gastric venous drainage into the area was demonstrated on arteriography in both cases. The variation in blood supply caused by AGVD may play an important role in fatty metabolism in the PENIS of the liver and may influence imaging features. 9 refs., 2 figs.« less

  18. The role of HRCT and three-dimensional VR CT findings in patients of congenital atresia combined with microtia.

    PubMed

    Gao, Ruzhen; Wang, Yun; Fan, Yue; Ai, Xing; Zhang, Xiaona; Xue, Huadan; Chen, Xiaowei; Jin, Zhengyu

    2012-12-01

    To determine the anatomic differences in patients of atresia by using high-resolution computed tomography (HRCT) and 3D volume rendered (VR) CT. High-resolution computed tomography (HRCT) was performed in 43 atresia patients including 34 unilateral atresia patients (n=34, 26 males, 8 females, mean age 13.82 years, range 8-19 years) and 9 bilateral atresia patients (6 males, 3 females, mean age 13.2 years, range 9-19 years). HRCT and 3D VR findings were compared with those in 43 normal ears of the unilateral atresia patients with normal PTA results (n=34, 26 males, 8 females, mean age 13.82 years, range 8-19 years) and 11 patients with sensorineural hearing loss but with no associated aplasia of the middle and inner ear (n=22, 7 males and 4 females, range 8-20.8 years, median age of 13.4 years) by using the independent one sample T test. On the HRCT images, the angle between the basic line and the tympanic segment of the facial nerve is more acute. And the area of the malleus-incus-joint or the malleus-incus-complex in the diseased ears is smaller than that in the control subjects (P<0.05). The tympanic segment is shorter and the area of the tympanic cavity is smaller in the atresia group, while the diameter of the oval window is also smaller in atresia group than that in the control group (P<0.05). The morphologic differences of the small ossicles and the entire length of the tympanic and mastoid segments can be depicted on a single 3D VR CT image. The facial nerve demonstrates abnormal lateral and anterior displacement in the CAA patients and the area of the Malleus-incus-joint and the tympanic cavity are significantly smaller, and the oval window is much narrower in the control group. HRCT and 3D VR CT provide valuable information about preoperative planning of patients with CAA. Measurements of all the angles and length serve as useful adjunct measurements in determining surgical candidacy. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Cholesterol granuloma of the petrous apex: CT diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lo, W.W.M.; Solti-Bohman, L.G.; Brackmann, D.E.

    Cholesterol granuloma of the petrous apex is a readily recognizable and treatable entity that is more common than previously realized. Cholesterol granuloma grows slowly in the petrous apex as a mass lesion until it produces hearing loss, tinnitus, vertigo, and facial twitching. Twelve cases of cholesterol granuloma of the petrous apex are illustrated; ten of these analyzed in detail, especially with respect to CT findings. A sharply and smoothly marginated expansile lesion in the petrous apex, isodense with plain and nonenhancing on CT, is in all probability a cholesterol granuloma. Preoperative recognition by CT is important for planning proper treatment.

  20. Cardiopulmonary manifestations of isolated pulmonary valve infective endocarditis demonstrated with cardiac CT.

    PubMed

    Passen, Edward; Feng, Zekun

    2015-01-01

    Right-sided infective endocarditis involving the pulmonary valve is rare. This pictorial essay discusses the use and findings of cardiac CT combined with delayed chest CT and noncontrast chest CT of pulmonary valve endocarditis. Cardiac CT is able to show the full spectrum of right-sided endocarditis cardiopulmonary features including manifestations that cannot be demonstrated by echocardiography. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  1. CT-Pathologic Correlation of Major Types of Pulmonary Fibrosis: Insights for Revisions to Current Guidelines.

    PubMed

    Chung, Jonathan H; Oldham, Justin M; Montner, Steven M; Vij, Rekha; Adegunsoye, Ayodeji; Husain, Aliya N; Noth, Imre; Lynch, David A; Strek, Mary E

    2018-05-01

    The purpose of this study was to assess the diagnostic significance of CT patterns that cannot be classified according to current idiopathic pulmonary fibrosis (IPF) guidelines and of specific findings of the inconsistent with usual interstitial pneumonitis (UIP) pattern. Subjects with a multidisciplinary diagnosis of interstitial lung disease who had undergone surgical lung biopsy and chest CT within 1 year of each other were included in the study. The predominant distribution and pattern of disease were scored. Cases were classified as UIP, possible UIP, or inconsistent with UIP at chest CT according to 2011 IPF guidelines. Cases that could not be confidently categorized with current guidelines were annotated as indeterminate. UIP, possible UIP, and inconsistent with UIP CT patterns were associated with pathologic UIP in 89.6%, 81.6%, and 60.0% of subjects. An indeterminate CT pattern (7.7% [20/259]) was associated with a UIP pathologic diagnosis in 55.0% of cases. This finding was not statistically different from the findings in the group with the inconsistent with UIP CT pattern (p = 0.677) but was different from the findings in the UIP (p < 0.001) and possible UIP (p = 0.031) groups. In regard to specific findings of the inconsistent with UIP CT category, ground-glass opacity, air-trapping, consolidation, and axial distribution were associated with a non-UIP pathologic diagnosis; however, there was no significant association with zonal distribution. A substantial minority of cases cannot be confidently categorized according to current guidelines for IPF and differ diagnostically from the possible UIP and UIP CT categories. The term "inconsistent with UIP" is misleading and should be renamed.

  2. Pre-surgical CT-assessment of neurogenic myositis ossificans of the hip and risk factors of recurrence: a series of 101 consecutive patients.

    PubMed

    Law-Ye, Bruno; Hangard, Chloé; Felter, Adrien; Safa, Dominique; Denormandie, Philippe; Genet, François; Carlier, Robert-Yves

    2016-10-18

    Neurogenic Myositis Ossificans (NMO) is a rare disabling pathology characterized by peri-articular heterotopic ossifications following severe peripheral or central nervous system injuries. It results in ankylosis and vessels or nerves compressions. Our study aimed to describe the pre-operative findings of patients with NMO of the hip using biphasic computerized tomography (CT). Between 2006 and 2012, we retrospectively analyzed 101 consecutive patients with hip NMO. We analyzed all CTs and surgical reports following a standardized grid depicting the osteoma and its relations with joint capsule, vessels and nerves and bone mineralization. We studied surgical complications and recurrence during follow-up. Chi2-test and Fischer's test were performed to compare qualitative values with respectively normal and non-normal distribution. Quantitative values were analyzed with a one factor analysis of variance (ANOVA) test. Agreement between pre-surgical CT and surgical observations was evaluated with Cohen's kappa test. Correlation between pre-operative CT and surgical findings was excellent regarding relationships with vessels (0,82) and was good concerning relationships with sciatic nerves (0.62) and with joint capsule (0.68). Close contact or disruption of joint capsule (p = 0.005), joint space narrowing (p = 0.007) and bone demineralization (p < 0.001) were correlated with NMO recurrence. Biphasic enhanced-CT allows pre-operative assessment of NMO with good correlation to surgical observations and helps prevent surgical complications.

  3. Direct evidence of a sub-stellar companion around CT Chamaeleontis

    NASA Astrophysics Data System (ADS)

    Schmidt, T. O. B.; Neuhäuser, R.; Seifahrt, A.; Vogt, N.; Bedalov, A.; Helling, Ch.; Witte, S.; Hauschildt, P. H.

    2008-11-01

    temperature and luminosity (log(L_bol/L⊙) = -2.68 ± 0.21), we derive a radius of R = 2.20_-0.60+0.81 RJup. We find a consistent mass of M = 17 ± 6 MJup for the CT Cha companion from both its luminosity and temperature when placed on evolutionary tracks. Hence, the CT Cha companion is most likely a wide brown dwarf companion or possibly even a planetary mass object. Based on observations made with ESO telescopes at the Paranal Observatory under program IDs 076.C-0292(A), 078.C-0535(A), & 279.C-5010(A). Color versions of Figs. 4, 6, 8 and 11 are only available in electronic form at http://www.aanda.org

  4. Photon counting spectral breast CT: effect of adaptive filtration on CT numbers, noise, and contrast to noise ratio.

    PubMed

    Silkwood, Justin D; Matthews, Kenneth L; Shikhaliev, Polad M

    2013-05-01

    Photon counting spectral (PCS) computed tomography (CT) shows promise for breast imaging. An issue with current photon-counting detectors is low count rate capabilities, artifacts resulting from nonuniform count rate across the field of view, and suboptimal spectral information. These issues are addressed in part by using tissue-equivalent adaptive filtration of the x-ray beam. The purpose of the study was to investigate the effect of adaptive filtration on different aspects of PCS breast CT. The theoretical formulation for the filter shape was derived for different filter materials and evaluated by simulation and an experimental prototype of the filter was fabricated from a tissue-like material (acrylic). The PCS CT images of a glandular breast phantom with adipose and iodine contrast elements were simulated at 40, 60, 90, and 120 kVp tube voltages, with and without adaptive filter. The CT numbers, CT noise, and contrast-to-noise ratio (CNR) were compared for spectral CT images acquired with and without adaptive filters. Similar comparison was made for material-decomposed PCS CT images. The adaptive filter improved the uniformity of CT numbers, CT noise, and CNR in both ordinary and material decomposed PCS CT images. At the same tube output the average CT noise with adaptive filter, although uniform, was higher than the average noise without adaptive filter due to x-ray absorption by the filter. Increasing tube output, so that average skin exposure with the adaptive filter was same as without filter, made the noise with adaptive filter comparable to or lower than that without adaptive filter. Similar effects were observed when energy weighting was applied, and when material decompositions were performed using energy selective CT data. An adaptive filter decreases count rate requirements to the photon counting detectors which enables PCS breast CT based on commercially available detector technologies. Adaptive filter also improves image quality in PCS breast CT by

  5. CT visible internal stone structure, but not Hounsfield unit value, of calcium oxalate monohydrate (COM) calculi predicts lithotripsy fragility in vitro.

    PubMed

    Zarse, Chad A; Hameed, Tariq A; Jackson, Molly E; Pishchalnikov, Yuri A; Lingeman, James E; McAteer, James A; Williams, James C

    2007-08-01

    Calcium oxalate monohydrate (COM) stones are often resistant to breakage using shock wave (SW) lithotripsy. It would be useful to identify by computed tomography (CT) those COM stones that are susceptible to SW's. For this study, 47 COM stones (4-10 mm in diameter) were scanned with micro CT to verify composition and also for assessment of heterogeneity (presence of pronounced lobulation, voids, or apatite inclusions) by blinded observers. Stones were then placed in water and scanned using 64-channel helical CT. As with micro CT, heterogeneity was assessed by blinded observers, using high-bone viewing windows. Then stones were broken in a lithotripter (Dornier Doli-50) over 2 mm mesh, and SW's counted. Results showed that classification of stones using micro CT was highly repeatable among observers (kappa = 0.81), and also predictive of stone fragility. Stones graded as homogeneous required 1,874 +/- 821 SW/g for comminution, while stones with visible structure required half as many SW/g, 912 +/- 678. Similarly, when stones were graded by appearance on helical CT, classification was repeatable (kappa = 0.40), and homogeneous stones required more SW's for comminution than did heterogeneous stones (1,702 +/- 993 SW/g, compared to 907 +/- 773). Stone fragility normalized to stone size did not correlate with Hounsfield units (P = 0.85). In conclusion, COM stones of homogeneous structure require almost twice as many SW's to comminute than stones of similar mineral composition that exhibit internal structural features that are visible by CT. This suggests that stone fragility in patients could be predicted using pre-treatment CT imaging. The findings also show that Hounsfield unit values of COM stones did not correlate with stone fragility. Thus, it is stone morphology, rather than X-ray attenuation, which correlates with fragility to SW's in this common stone type.

  6. Correlation of emphysema score with perceived malignancy of pulmonary nodules: a multi-observer study using the LIDC-IDRI CT lung database

    NASA Astrophysics Data System (ADS)

    Wiemker, Rafael; Bülow, Thomas; Blaffert, Thomas; Dharaiya, Ekta

    2009-02-01

    Presence of emphysema is recognized to be one of the single most significant risk factors in risk models for the prediction of lung cancer. Therefore, an automatically computed emphysema score would be a prime candidate as an additional numerical feature for computer aided diagnosis (CADx) for indeterminate pulmonary nodules. We have applied several histogram-based emphysema scores to 460 thoracic CT scans from the IDRI CT lung image database, and analyzed the emphysema scores in conjunction with 3000 nodule malignancy ratings of 1232 pulmonary nodules made by expert observers. Despite the emphysema being a known risk factor, we have not found any impact on the readers' malignancy rating of nodules found in a patient with higher emphysema score. We have also not found any correlation between the number of expert-detected nodules in a patient and his emphysema score, or the relative craniocaudal location of the nodules and their malignancy rating. The inter-observer agreement of the expert ratings was excellent on nodule diameter (as derived from manual delineations), good for calcification, and only modest for malignancy and shape descriptions such as spiculation, lobulation, margin, etc.

  7. Does head CT scan pathology predict outcome after mild traumatic brain injury?

    PubMed

    Lannsjö, M; Backheden, M; Johansson, U; Af Geijerstam, J L; Borg, J

    2013-01-01

    More evidence is needed to forward our understanding of the key determinants of poor outcome after mild traumatic brain injury (MTBI). A large, prospective, national cohort of patients was studied to analyse the effect of head CT scan pathology on the outcome. One-thousand two-hundred and sixty-two patients with MTBI (Glasgow Coma Scale score 15) at 39 emergency departments completed a study protocol including acute head CT scan examination and follow-up by the Rivermead Post Concussion Symptoms Questionnaire and the Glasgow Outcome Scale Extended (GOSE) at 3 months after MTBI. Binary logistic regression was used for the assessment of prediction ability. In 751 men (60%) and 511 women (40%), with a mean age of 30 years (median 21, range 6-94), we observed relevant or suspect relevant pathologic findings on acute CT scan in 52 patients (4%). Patients aged below 30 years reported better outcome both with respect to symptoms and GOSE as compared to patients in older age groups. Men reported better outcome than women as regards symptoms (OR 0.64, CI 0.49-0.85 for ≥3 symptoms) and global function (OR 0.60, CI 0.39-0.92 for GOSE 1-6). Pathology on acute CT scan examination had no effect on self-reported symptoms or global function at 3 months after MTBI. Female gender and older age predicted a less favourable outcome. The findings support the view that other factors than brain injury deserve attention to minimize long-term complaints after MTBI. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  8. Common Postmortem Computed Tomography Findings Following Atraumatic Death: Differentiation between Normal Postmortem Changes and Pathologic Lesions

    PubMed Central

    Gonoi, Wataru; Okuma, Hidemi; Shirota, Go; Shintani, Yukako; Abe, Hiroyuki; Takazawa, Yutaka; Fukayama, Masashi; Ohtomo, Kuni

    2015-01-01

    Computed tomography (CT) is widely used in postmortem investigations as an adjunct to the traditional autopsy in forensic medicine. To date, several studies have described postmortem CT findings as being caused by normal postmortem changes. However, on interpretation, postmortem CT findings that are seemingly due to normal postmortem changes initially, may not have been mere postmortem artifacts. In this pictorial essay, we describe the common postmortem CT findings in cases of atraumatic in-hospital death and describe the diagnostic pitfalls of normal postmortem changes that can mimic real pathologic lesions. PMID:26175579

  9. Patient doses from CT examinations in Turkey.

    PubMed

    Ataç, Gökçe Kaan; Parmaksız, Aydın; İnal, Tolga; Bulur, Emine; Bulgurlu, Figen; Öncü, Tolga; Gündoğdu, Sadi

    2015-01-01

    We aimed to establish the first diagnostic reference levels (DRLs) for computed tomography (CT) examinations in adult and pediatric patients in Turkey and compare these with international DRLs. CT performance information and examination parameters (for head, chest, high-resolution CT of the chest [HRCT-chest], abdominal, and pelvic protocols) from 1607 hospitals were collected via a survey. Dose length products and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIvol). The median number of protocols reported from the 167 responding hospitals (10% response rate) was 102 across five different age groups. Third quartile CTDIvol values for adult pelvic and all pediatric body protocols were higher than the European Commission standards but were comparable to studies conducted in other countries. The radiation dose indicators for adult patients were similar to those reported in the literature, except for those associated with head protocols. CT protocol optimization is necessary for adult head and pediatric chest, HRCT-chest, abdominal, and pelvic protocols. The findings from this study are recommended for use as national DRLs in Turkey.

  10. Ultrasonography and contrast-enhanced CT findings of tularemia in the neck

    PubMed Central

    Doğan, Serap; Ekinci, Afra; Demiraslan, Hayati; Kılıç, Ayşegül Ulu; Mavili, Ertuğrul; Öztürk, Mustafa; İmamoğlu, Hakan; Doğanay, Mehmet

    2016-01-01

    PURPOSE We aimed to evaluate the ultrasonography (US) and contrast-enhanced computed tomography (CECT) findings of tularemia in the neck. METHODS US and CECT findings of 58 patients with serologically proven tularemia were retrospectively evaluated. Forty-eight patients underwent US and 42 patients underwent CECT. Lymph node characteristics and parotid preauricular region involvement were analyzed using US and CECT. In addition, involvement of larynx, oropharynx, and retropharynx; presence of periorbital edema; and neck abscess formation were evaluated using CECT. Fine needle aspiration cytology (FNAC) results of enlarged lymph nodes were analyzed in 29 patients. RESULTS Hypoechoic pattern, round shape, absence of hilum, and cystic necrosis were seen in most of the lymph nodes especially at level 2 and 3 on US and CECT. Matting was more commonly observed than irregular nodal border on US and CECT. Parotid preauricular region involvement was seen in 20.8% of patients on US. Oropharyngeal, retropharyngeal, laryngeal and parotid preauricular region involvement and periorbital edema were seen in 52.4%, 19.1%, 4.8%, 31%, and 9.5% of tularemia patients, respectively. Neck abscess was found in 59.5% of patients on CECT. Suppurative inflammation was the most common finding of FNAC. CONCLUSION Tularemia should be considered in the presence of level 2 and 3 lymph nodes with cystic necrosis, matting, absence of calcification, oropharyngeal and retropharyngeal region involvement, and neck abscess, particularly in endemic areas. PMID:27498683

  11. Clinically-Important Brain Injury and CT Findings in Pediatric Mild Traumatic Brain Injuries: A Prospective Study in a Chinese Reference Hospital

    PubMed Central

    Zhu, Huiping; Gao, Qi; Xia, Xin; Xiang, Joe; Yao, Hongli; Shao, Jianbo

    2014-01-01

    This study investigated injury patterns and the use of computed tomography (CT) among Chinese children with mild traumatic brain injury (MTBI). We enrolled children with MTBI who were treated within 24 hours of head trauma in the emergency department of Wuhan Medical Care Center for Women and Children in Wuhan, China. Characteristics of MTBIs were analyzed by age and gender. Results of cranial CT scan and clinically-important brain injury (ciTBI) for children were obtained. The definition of ciTBI was: death from TBI, intubation for more than 24 h for TBI, neurosurgery, or hospital admission of 2 nights or more. Of 455 eligible patients with MTBI, ciTBI occurred in two, and no one underwent neurosurgical intervention. CT scans were performed for 441 TBI patients (96.9%), and abnormal findings were reported for 147 patients (33.3%, 95% CI 29.0–37.8). Falls were the leading cause of MTBI (61.5%), followed by blows (18.9%) and traffic collisions (14.1%) for children in the 0–2 group and 10–14 group. For children aged between 3 and 9, the top three causes of TBI were falls, traffic collisions and blows. Leisure activity was the most reported activity when injuries occurred for all age groups. Sleeping/resting and walking ranked in the second and third place for children between 0 and 2 years of age, and walking and riding for the other two groups. The places where the majority injuries occurred were the home for the 0–2 and 3–9 years of age groups, and school for the 10–14 years of age group. There was no statistical difference between boys and girls with regard to the activity that caused the MTBI. This study highlights the important roles that parents and school administrators in the development of preventive measures to reduce the risk of traumatic brain injury in children. Also, identifying children who had a head trauma at very low risk of clinically important TBI for whom CT might be unnecessary is a priority area of research in China. PMID:24675642

  12. Dual-phase CT for the assessment of acute vascular injuries in high-energy blunt trauma: the imaging findings and management implications.

    PubMed

    Iacobellis, Francesca; Ierardi, Anna M; Mazzei, Maria A; Magenta Biasina, Alberto; Carrafiello, Gianpaolo; Nicola, Refky; Scaglione, Mariano

    2016-01-01

    Acute vascular injuries are the second most common cause of fatalities in patients with multiple traumatic injuries; thus, prompt identification and management is essential for patient survival. Over the past few years, multidetector CT (MDCT) using dual-phase scanning protocol has become the imaging modality of choice in high-energy deceleration traumas. The objective of this article was to review the role of dual-phase MDCT in the identification and management of acute vascular injuries, particularly in the chest and abdomen following multiple traumatic injuries. In addition, this article will provide examples of MDCT features of acute vascular injuries with correlative surgical and interventional findings.

  13. "Buckle" rib fracture: an artifact following cardio-pulmonary resuscitation detected on postmortem CT.

    PubMed

    Yang, Kyung-Moo; Lynch, Matthew; O'Donnell, Chris

    2011-09-01

    Buckle rib fractures are incomplete fractures involving the inner cortex alone, and are rarely detected on routine chest X-ray or at autopsy. The characteristics of these fractures have not been well evaluated in situ although they are commonly observed on postmortem CT images especially following CPR. The postmortem CT findings in 42 cases showing buckle rib fractures caused by CPR were reviewed. The cause of death in all cases was non-traumatic. The shape, number, location, and distribution of these buckle rib fractures and their relationship to other types of rib fractures were evaluated using a novel oblique axial multiplanar reconstruction technique. Almost all incomplete rib fractures associated with CPR are buckle rib fractures (90.5%). All rib fractures were distributed from the second to ninth ribs with over 95% being within the second to seventh ribs. Buckle rib fractures are dominant in the seventh to ninth ribs and the proportion of buckle rib fractures located in the vicinity of the costochondral junctions increases with the lower ribs. Over 97% of all CPR associated rib fractures are located in the anterior one third of the ribs based on a new measurement method utilizing oblique axial multiplanar reconstruction of the CT data. When recognition of incomplete or buckle rib fractures on postmortem CT is taken into account, detection of symmetry and continuity of rib fractures typically associated with CPR is improved compared with the detection of complete fractures alone. Recognition of buckle rib fractures and their characteristics on postmortem CT is of benefit to the forensic pathologist in evaluating the possibility of CPR and the differentiation of resuscitative artifact from forensically significant visceral injury observed at autopsy. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. First CT findings and improvement in GOS and GOSE scores 6 and 12 months after severe traumatic brain injury.

    PubMed

    Corral, Luisa; Herrero, José Ignacio; Monfort, José Luis; Ventura, José Luis; Javierre, Casimiro F; Juncadella, Montserrat; García-Huete, Lucía; Bartolomé, Carlos; Gabarrós, Andreu

    2009-05-01

    To analyse the association between individual initial computerized tomography (CT) scan characteristics and Glasgow Outcome Scale (GOS) and Extended Glasgow Outcome Scale (GOSE) improvement between 6 months and 1 year. Two hundred and twenty-four adult patients with severe traumatic brain injury and Glasgow Coma Scale (GCS) score of 8 or less who were admitted to an intensive care unit were studied. GOS and GOSE scores were obtained 6 and 12 months after injury in 203 subjects. Patients were predominantly male (84%) and median age was 35 years. Traumatic Coma Data Bank (TCDB) CT classification was associated with GOS/GOSE improvement between 6 months and 1 year, with diffuse injury type I, type II and evacuated mass improving more than diffuse injury type III, type IV and non-evacuated mass; for GOS 43/155 (28%) vs 3/48 (6%) (chi(2) = 9.66, p < 0.01) and for GOSE 71/155 (46%) vs 7/48 (15%) (chi(2) = 15.1, p < 0.01). CT individual abnormalities were not associated with GOS/GOSE improvement, with the exception of subarachnoid haemorrhage, which showed a negative association with GOSE improvement (chi(2) = 4.08, p < 0.05). TCDB CT scan classification and subarachnoid haemorrhage were associated with GOS/GOSE improvement from 6-12 months, but individual CT abnormalities were not associated.

  15. Head CT scan

    MedlinePlus

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... conditions: Birth (congenital) defect of the head or brain Brain infection Brain tumor Buildup of fluid inside ...

  16. Query Expansion Using SNOMED-CT and Weighing Schemes

    DTIC Science & Technology

    2014-11-01

    For this research, we have used SNOMED-CT along with UMLS Methathesaurus as our ontology in medical domain to expand the queries. General Terms...CT along with UMLS Methathesaurus as our ontology in medical domain to expand the queries. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17...University of the Basque country discuss their finding on query expansion using external sources headlined by Unified Medical Language System ( UMLS

  17. Renal incidental findings on computed tomography

    PubMed Central

    Meyer, Hans Jonas; Pfeil, Alina; Schramm, Dominik; Bach, Andreas Gunter; Surov, Alexey

    2017-01-01

    Abstract Renal incidental findings (IFs) are common. However, previous reports investigated renal IFs were limited to patient selection. The purpose of this study was to estimate the prevalence and distribution of all renal IFs on computed tomography (CT) in a large patient collective. All patients, who underwent CT investigations of the abdominal region at our institution in the time period between January 2006 and February 2014 were included in this study. Inclusion criteria were as follows: no previous history of renal diseases and well image quality. Patients with known kidney disorders were excluded from the study. Overall, 7365 patients meet the inclusion criteria were identified. There were 2924 (39.7%) women and 4441 men (60.3%) with a mean age of 59.8 ± 16.7 years. All CTs were retrospectively analyzed in consensus by 2 radiologists. Collected data were evaluated by means of descriptive statistics. Overall, 2756 patients (37.42% of all included patients) showed 3425 different renal IFs (1.24 findings per patient). Of all renal IFs, 123 (3.6%) findings were clinically relevant, 259 (7.6%) were categorized as possibly clinically relevant, and 3043 (88.8%) were clinically non relevant. Different renal IFs can be detected on CT. The present study provides a real prevalence and proportion of them in daily clinical routine. Kidneys should be thoroughly evaluated because of the fact that incidental renal findings occur frequently. PMID:28658098

  18. Neuroimaging findings in children with retinopathy-confirmed cerebral malaria.

    PubMed

    Potchen, Michael J; Birbeck, Gretchen L; Demarco, J Kevin; Kampondeni, Sam D; Beare, Nicholas; Molyneux, Malcolm E; Taylor, Terrie E

    2010-04-01

    To describe brain CT findings in retinopathy-confirmed, paediatric cerebral malaria. In this outcomes study of paediatric cerebral malaria, a subset of children with protracted coma during initial presentation was scanned acutely. Survivors experiencing adverse neurological outcomes also underwent a head CT. All children had ophthalmological examination to confirm the presence of the retinopathy specific for cerebral malaria. Independent interpretation of CT images was provided by two neuroradiologists. Acute brain CT findings in three children included diffuse oedema with obstructive hydrocephalus (2), acute cerebral infarctions in multiple large vessel distributions with secondary oedema and herniation (1), and oedema of thalamic grey matter (1). One child who was reportedly normal prior to admission had parenchymal atrophy suggestive of pre-existing CNS injury. Among 56 survivors (9-84 months old), 15 had adverse neurologic outcomes-11/15 had a follow-up head CT, 3/15 died and 1/15 refused CT. Follow-up head CTs obtained 7-18 months after the acute infection revealed focal and multifocal lobar atrophy correlating to regions affected by focal seizures during the acute infection (5/11). Other findings were communicating hydrocephalus (2/11), vermian atrophy (1/11) and normal studies (3/11). The identification of pre-existing imaging abnormalities in acute cerebral malaria suggests that population-based studies are required to establish the rate and nature of incidental imaging abnormalities in Malawi. Children with focal seizures during acute cerebral malaria developed focal cortical atrophy in these regions at follow-up. Longitudinal studies are needed to further elucidate mechanisms of CNS injury and death in this common fatal disease. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Comparison of computational to human observer detection for evaluation of CT low dose iterative reconstruction

    NASA Astrophysics Data System (ADS)

    Eck, Brendan; Fahmi, Rachid; Brown, Kevin M.; Raihani, Nilgoun; Wilson, David L.

    2014-03-01

    Model observers were created and compared to human observers for the detection of low contrast targets in computed tomography (CT) images reconstructed with an advanced, knowledge-based, iterative image reconstruction method for low x-ray dose imaging. A 5-channel Laguerre-Gauss Hotelling Observer (CHO) was used with internal noise added to the decision variable (DV) and/or channel outputs (CO). Models were defined by parameters: (k1) DV-noise with standard deviation (std) proportional to DV std; (k2) DV-noise with constant std; (k3) CO-noise with constant std across channels; and (k4) CO-noise in each channel with std proportional to CO variance. Four-alternative forced choice (4AFC) human observer studies were performed on sub-images extracted from phantom images with and without a "pin" target. Model parameters were estimated using maximum likelihood comparison to human probability correct (PC) data. PC in human and all model observers increased with dose, contrast, and size, and was much higher for advanced iterative reconstruction (IMR) as compared to filtered back projection (FBP). Detection in IMR was better than FPB at 1/3 dose, suggesting significant dose savings. Model(k1,k2,k3,k4) gave the best overall fit to humans across independent variables (dose, size, contrast, and reconstruction) at fixed display window. However Model(k1) performed better when considering model complexity using the Akaike information criterion. Model(k1) fit the extraordinary detectability difference between IMR and FBP, despite the different noise quality. It is anticipated that the model observer will predict results from iterative reconstruction methods having similar noise characteristics, enabling rapid comparison of methods.

  20. Stratified computed tomography findings improve diagnostic accuracy for appendicitis

    PubMed Central

    Park, Geon; Lee, Sang Chul; Choi, Byung-Jo; Kim, Say-June

    2014-01-01

    AIM: To improve the diagnostic accuracy in patients with symptoms and signs of appendicitis, but without confirmative computed tomography (CT) findings. METHODS: We retrospectively reviewed the database of 224 patients who had been operated on for the suspicion of appendicitis, but whose CT findings were negative or equivocal for appendicitis. The patient population was divided into two groups: a pathologically proven appendicitis group (n = 177) and a non-appendicitis group (n = 47). The CT images of these patients were re-evaluated according to the characteristic CT features as described in the literature. The re-evaluations and baseline characteristics of the two groups were compared. RESULTS: The two groups showed significant differences with respect to appendiceal diameter, and the presence of periappendiceal fat stranding and intraluminal air in the appendix. A larger proportion of patients in the appendicitis group showed distended appendices larger than 6.0 mm (66.3% vs 37.0%; P < 0.001), periappendiceal fat stranding (34.1% vs 8.9%; P = 0.001), and the absence of intraluminal air (67.6% vs 48.9%; P = 0.024) compared to the non-appendicitis group. Furthermore, the presence of two or more of these factors increased the odds ratio to 6.8 times higher than baseline (95%CI: 3.013-15.454; P < 0.001). CONCLUSION: Appendiceal diameter and wall thickening, fat stranding, and absence of intraluminal air can be used to increased diagnostic accuracy for appendicitis with equivocal CT findings. PMID:25320531

  1. Conspicuity of renal calculi at unenhanced CT: effects of calculus composition and size and CT technique.

    PubMed

    Tublin, Mitchell E; Murphy, Michael E; Delong, David M; Tessler, Franklin N; Kliewer, Mark A

    2002-10-01

    To determine the effects of calculus size, composition, and technique (kilovolt and milliampere settings) on the conspicuity of renal calculi at unenhanced helical computed tomography (CT). The authors performed unenhanced CT of a phantom containing 188 renal calculi of varying size and chemical composition (brushite, cystine, struvite, weddellite, whewellite, and uric acid) at 24 combinations of four kilovolt (80-140 kV) and six milliampere (200-300 mA) levels. Two radiologists, who were unaware of the location and number of calculi, reviewed the CT images and recorded where stones were detected. These observations were compared with the known positions of calculi to generate true-positive and false-positive rates. Logistic regression analysis was performed to investigate the effects of stone size, composition, and technique and to generate probability estimates of detection. Interobserver agreement was estimated with kappa statistics. Interobserver agreement was high: the mean kappa value for the two observers was 0.86. The conspicuity of stone fragments increased with increasing kilovolt and milliampere levels for all stone types. At the highest settings (140 kV and 300 mA), the detection threshold size (ie, the size of calculus that had a 50% probability of being detected) ranged from 0.81 mm + 0.03 (weddellite) to 1.3 mm + 0.1 (uric acid). Detection threshold size for each type of calculus increased up to 1.17-fold at lower kilovolt settings and up to 1.08-fold at lower milliampere settings. The conspicuity of small renal calculi at CT increases with higher kilovolt and milliampere settings, with higher kilovolts being particularly important. Small uric acid calculi may be imperceptible, even with maximal CT technique.

  2. Preoperative Radiographic and CT Findings Predicting Syndesmotic Injuries in Supination-External Rotation-Type Ankle Fractures.

    PubMed

    Choi, Young; Kwon, Soon-Sun; Chung, Chin Youb; Park, Moon Seok; Lee, Seung Yeol; Lee, Kyoung Min

    2014-07-16

    The Lauge-Hansen classification system does not provide sufficient data related to syndesmotic injuries in supination-external rotation (SER)-type ankle fractures. The aim of the present study was to investigate factors helpful for the preoperative detection of syndesmotic injuries in SER-type ankle fractures using radiographs and computed tomography (CT). A cohort of 191 consecutive patients (104 male and eighty-seven female patients with a mean age [and standard deviation] of 50.7 ± 16.4 years) with SER-type ankle fractures who had undergone operative treatment were included. Preoperative ankle radiographs and CT imaging scans were made for all patients, and clinical data, including age, sex, and mechanism of injury (high or low-energy trauma), were collected. Patients were divided into two groups: the stable syndesmotic group and the unstable syndesmotic group, with a positive intraoperative lateral stress test leading to syndesmotic screw fixation. Fracture height, fracture length, medial joint space, extent of fracture, and bone attenuation were measured on radiographs and CT images and were compared between the groups. Binary logistic regression analysis was performed to identify the factors that significantly contributed to unstable syndesmotic injuries. Receiver operating characteristic curves were calculated, and cutoff values were suggested to predict unstable syndesmotic injuries on preoperative imaging measurements. Of the 191 patents with a SER-type ankle fracture, thirty-eight (19.9%) had a concurrent unstable syndesmotic injury. Age, sex, mechanism of injury, fracture height, medial joint space, and bone attenuation were significantly different between the two groups. In the binary logistic analysis, fracture height, medial joint space, and bone attenuation were found to be significant factors contributing to unstable syndesmotic injuries. The cutoff values for predicting unstable syndesmotic injuries were a fracture height of >3 mm and a medial

  3. Imaging Findings of Ulceroglandular Tularemia.

    PubMed

    Anand, Neil; Deochand, Osmani; Murphy, Robyn

    2017-01-01

    Francisella tularensis, the causative organism in Tularemia, is a relatively rare disease. There are a few radiological clues to elucidate its presence when suspicion arises. There should be strong consideration for Tularemia in the differential of any patient with its classic symptoms, diffuse cervical lymphadenopathy with evidence of necrosis, and enlarged adenoids. Ultrasound may demonstrate suppurative lymphadenopathy suggestive of infection, as in the case presented. CT often will demonstrate the extent of lymphadenopathy. On chest radiography, tularemia pneumonia is often the presenting finding, which may demonstrate bilateral or lobar infiltrates. Additionally, hilar lymphadenopathy and pleural effusions are often associated findings. Cavitary lesions may be present, which are better delineated on CT scan. We present a case of a 7-year-old male who presented with a painful right-sided palpable neck mass for 9 days, who was diagnosed with Tularemia after numerous admissions.

  4. Organizing pneumonia pattern in the follow-up CT of Legionella-infected patients.

    PubMed

    Haroon, Attiya; Higa, Futoshi; Hibiya, Kenji; Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao; Fujita, Jiro

    2011-08-01

    The main aim of this study was to describe the appearance of the CT pattern of organizing pneumonia in Legionella-infected patients. Serial CT scans obtained from five sporadic cases of Legionella pneumophila pneumonia were retrospectively reviewed. The mean time of follow-up was 14 days. Chest CT was analyzed with regard to frequency and appearance of CT patterns of pulmonary abnormalities. Consolidation and ground-glass opacities, with or without an air bronchogram, were the most common abnormalities detected in CT scans during follow-up patients with L. pneumophila pneumonia. Two patterns were observed: subpleural and peribronchovascular. The subpleural pattern was seen in four patients and the peribronchovascular pattern in one. Interlobular septal thickening was seen in one patient. Pleural effusion was seen in one patient. The CT pattern of organizing pneumonia, a subpleural pattern, was frequently observed after treatment of L. pneumophila pneumonia.

  5. Prognostic value of CtIP/RBBP8 expression in breast cancer.

    PubMed

    Soria-Bretones, Isabel; Sáez, Carmen; Ruíz-Borrego, Manuel; Japón, Miguel A; Huertas, Pablo

    2013-12-01

    CtIP/RBBP8 is a multifunctional protein involved in transcription, DNA replication, DNA repair by homologous recombination and the G1 and G2 checkpoints. Its multiple roles are controlled by its interaction with several specific factors, including the tumor suppressor proteins BRCA1 and retinoblastoma. Both its functions and interactors point to a putative oncogenic potential of CtIP/RBBP8 loss. However, CtIP/RBBP8 relevance in breast tumor appearance, development, and prognosis has yet to be established. We performed a retrospective analysis of CtIP/RBBP8 and RB1 levels by immunohistochemistry using 384 paraffin-embedded breast cancer biopsies obtained during tumor removal surgery. We have observed that low or no expression of CtIP/RBBP8 correlates with high-grade breast cancer and with nodal metastasis. Reduction on CtIP/RBBP8 is most common in hormone receptor (HR)-negative, HER2-positive, and basal-like tumors. We observed lower levels of RB1 on those tumors with reduced CtIP/RBBP8 levels. On luminal tumors, decreased but not absence of CtIP/RBBP8 levels correlate with increased disease-free survival when treated with a combination of hormone, radio, and chemo therapies. © 2013 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  6. Prognostic value of CtIP/RBBP8 expression in breast cancer

    PubMed Central

    Soria-Bretones, Isabel; Sáez, Carmen; Ruíz-Borrego, Manuel; Japón, Miguel A; Huertas, Pablo

    2013-01-01

    CtIP/RBBP8 is a multifunctional protein involved in transcription, DNA replication, DNA repair by homologous recombination and the G1 and G2 checkpoints. Its multiple roles are controlled by its interaction with several specific factors, including the tumor suppressor proteins BRCA1 and retinoblastoma. Both its functions and interactors point to a putative oncogenic potential of CtIP/RBBP8 loss. However, CtIP/RBBP8 relevance in breast tumor appearance, development, and prognosis has yet to be established. We performed a retrospective analysis of CtIP/RBBP8 and RB1 levels by immunohistochemistry using 384 paraffin-embedded breast cancer biopsies obtained during tumor removal surgery. We have observed that low or no expression of CtIP/RBBP8 correlates with high-grade breast cancer and with nodal metastasis. Reduction on CtIP/RBBP8 is most common in hormone receptor (HR)-negative, HER2-positive, and basal-like tumors. We observed lower levels of RB1 on those tumors with reduced CtIP/RBBP8 levels. On luminal tumors, decreased but not absence of CtIP/RBBP8 levels correlate with increased disease-free survival when treated with a combination of hormone, radio, and chemo therapies. PMID:24403251

  7. Reappraisal of Pediatric Diastatic Skull Fractures in the 3-Dimensional CT Era: Clinical Characteristics and Comparison of Diagnostic Accuracy of Simple Skull X-Ray, 2-Dimensional CT, and 3-Dimensional CT.

    PubMed

    Sim, Sook Young; Kim, Hyun Gi; Yoon, Soo Han; Choi, Jong Wook; Cho, Sung Min; Choi, Mi Sun

    2017-12-01

    Diastatic skull fractures (DSFs) in children are difficult to detect in skull radiographs before they develop into growing skull fractures; therefore, little information is available on this topic. However, recent advances in 3-dimensional (3D) computed tomography (CT) imaging technology have enabled more accurate diagnoses of almost all forms of skull fracture. The present study was undertaken to document the clinical characteristics of DSFs in children and to determine whether 3D CT enhances diagnostic accuracy. Two hundred and ninety-two children younger than 12 years with skull fractures underwent simple skull radiography, 2-dimensional (2D) CT, and 3DCT. Results were compared with respect to fracture type, location, associated lesions, and accuracy of diagnosis. DSFs were diagnosed in 44 (15.7%) of children with skull fractures. Twenty-two patients had DSFs only, and the other 22 had DSFs combined with compound or mixed skull fractures. The most common fracture locations were the occipitomastoid (25%) and lambdoid (15.9%). Accompanying lesions consisted of subgaleal hemorrhages (42/44), epidural hemorrhages (32/44), pneumocephalus (17/44), and subdural hemorrhages (3/44). A total of 17 surgical procedures were performed on 15 of the 44 patients. Fourteen and 19 patients were confirmed to have DSFs by skull radiography and 2D CT, respectively, but 3D CT detected DSFs in 43 of the 44 children (P < 0.001). 3D CT was found to be markedly superior to skull radiography or 2D CT for detecting DSFs. This finding indicates that 3D CT should be used routinely rather than 2D CT for the assessment of pediatric head trauma. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Characteristic findings on panoramic radiography and cone-beam CT to predict paresthesia after extraction of impacted third molar.

    PubMed

    Harada, Nana; Beloor Vasudeva, Subash; Matsuda, Yukiko; Seki, Kenji; Kapila, Rishabh; Ishikawa, Noboru; Okano, Tomohiro; Sano, Tsukasa

    2015-01-01

    The purpose of this study was to compare findings on the relationship between impacted molar roots and the mandibular canal in panoramic and three-dimensional cone-beam CT (CBCT) images to identify those that indicated risk of postoperative paresthesia. The relationship between impacted molars and the mandibular canal was first classified using panoramic images. Only patients in whom the molar roots were either in contact with or superimposed on the canal were evaluated using CBCT. Of 466 patients examined using both panoramic and CBCT images, 280 underwent surgical extraction of an impacted molar, and 15 of these (5%) reported postoperative paresthesia. The spatial relationship between the impacted third molar root and the mandibular canal was determined by examining para-sagittal sections (lingual, buccal, inter-radicular, inferior, and combinations) obtained from the canal to the molar root and establishing the proximity of the canal to the molar root (in contact with or without loss of the cortical border and separate). The results revealed that darkening of the roots with interruption of the mandibular canal on panoramic radiographs and the inter-radicular position of the canal in CBCT images were characteristic findings indicative of risk of postoperative paresthesia. These results suggest that careful surgical intervention is required in patients with the above characteristics.

  9. Vascular uterine abnormalities: Comparison of imaging findings and clinical outcomes.

    PubMed

    Hugues, Clara; Le Bras, Yann; Coatleven, Frederic; Brun, Jean-Luc; Trillaud, Hervé; Grenier, Nicolas; Cornelis, François

    2015-12-01

    To retrospectively compare the imaging findings and the outcomes for patients with vascular uterine abnormalities (VUA) and to identify prognostic factors. Between 2007 and 2012, 38 patients with vaginal bleeding and abnormal ultrasonographic (US) findings consistent with acquired VUA were consecutively included (mean age 31.6 years, range 19-62). Follow-up was 32 months in mean (1-78 months). Seventeen women (44.7%) started bleeding immediately after curettage, spontaneous miscarriage, trophoblastic disease, or section scars, with the remainder starting bleeding after 8 days to 2 years. All US, CT (n=2), MR (n=5) and angiographic (n=26) images were reviewed and compared to medical reports in order to identify severe VUA requiring treatment, and predictive factors. No information about severity was provided by US, MRI or CT. Twelve patients were successfully managed conservatively. Angiography identified 6 non-severe VUA, corresponding to an isolated uterine hyperemia, and 20 severe VUA, corresponding to an association of a nidus and early venous drainage. Recurrences were more often observed for severe VUA (p=0.001). The hemoglobin level was significantly lower (below 11 g/L) in these cases (p=0.004). Recurrences were significantly more frequently observed for patients with history of dilatation and curettage (p=0.02). Hysterectomy was performed for three patients only (8%). Among the women who wished to have children, 14 (77.8%) were pregnant after 9 months in mean (range 2-23). Recurrence happens more frequently after curettage and in case of anemia or severe VUA findings on angiography, justifying adequate embolization for these patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Autocalibration method for non-stationary CT bias correction.

    PubMed

    Vegas-Sánchez-Ferrero, Gonzalo; Ledesma-Carbayo, Maria J; Washko, George R; Estépar, Raúl San José

    2018-02-01

    Computed tomography (CT) is a widely used imaging modality for screening and diagnosis. However, the deleterious effects of radiation exposure inherent in CT imaging require the development of image reconstruction methods which can reduce exposure levels. The development of iterative reconstruction techniques is now enabling the acquisition of low-dose CT images whose quality is comparable to that of CT images acquired with much higher radiation dosages. However, the characterization and calibration of the CT signal due to changes in dosage and reconstruction approaches is crucial to provide clinically relevant data. Although CT scanners are calibrated as part of the imaging workflow, the calibration is limited to select global reference values and does not consider other inherent factors of the acquisition that depend on the subject scanned (e.g. photon starvation, partial volume effect, beam hardening) and result in a non-stationary noise response. In this work, we analyze the effect of reconstruction biases caused by non-stationary noise and propose an autocalibration methodology to compensate it. Our contributions are: 1) the derivation of a functional relationship between observed bias and non-stationary noise, 2) a robust and accurate method to estimate the local variance, 3) an autocalibration methodology that does not necessarily rely on a calibration phantom, attenuates the bias caused by noise and removes the systematic bias observed in devices from different vendors. The validation of the proposed methodology was performed with a physical phantom and clinical CT scans acquired with different configurations (kernels, doses, algorithms including iterative reconstruction). The results confirmed the suitability of the proposed methods for removing the intra-device and inter-device reconstruction biases. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. 18 F-FDG PET/CT for planning external beam radiotherapy alters therapy in 11% of 581 patients.

    PubMed

    Birk Christensen, Charlotte; Loft-Jakobsen, Annika; Munck Af Rosenschöld, Per; Højgaard, Liselotte; Roed, Henrik; Berthelsen, Anne K

    2018-03-01

    18 F-FDG PET/CT (FDG PET/CT) used in radiotherapy planning for extra-cerebral malignancy may reveal metastases to distant sites that may affect the choice of therapy. To investigate the role of FDG PET/CT on treatment strategy changes induced by the use of PET/CT as part of the radiotherapy planning. 'A major change of treatment strategy' was defined as either including more lesions in the gross tumour volume (GTV) distant from the primary tumour or a change in treatment modalities. The study includes 581 consecutive patients who underwent an FDG PET/CT scan for radiotherapy planning in our institution in the year 2008. All PET/CT scans were performed with the patient in treatment position with the use of immobilization devices according to the intended radiotherapy treatment. All scans were evaluated by a nuclear medicine physician together with a radiologist to delineate PET-positive GTV (GTV-PET). For 63 of the patients (11%), the PET/CT simulation scans resulted in a major change in treatment strategy because of the additional diagnostic information. Changes were most frequently observed in patients with lung cancer (20%) or upper gastrointestinal cancer (12%). In 65% of the patients for whom the PET/CT simulation scan revealed unexpected dissemination, radiotherapy was given - changed (n = 38) or unchanged (n = 13) according to the findings on the FDG PET/CT. Unexpected dissemination on the FDG PET/CT scanning performed for radiotherapy planning caused a change in treatment strategy in 11% of 581 patients. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. Pharyngitis of infectious mononucleosis: computed tomography findings.

    PubMed

    Kutuya, Naoki; Kurosaki, Yoshihisa; Suzuki, Kazuhiro; Takata, Koremochi; Shiraihshi, Akihiko

    2008-05-01

    Two women presented with sore throat and fever. Their symptoms were not alleviated by antibiotics. Cervical computed tomography (CT) with contrast enhancement demonstrated enlargement of predominant posterior cervical lymph nodes and streaky heterogeneous tonsils with interspersed low attenuation. They were diagnosed as having infectious mononucleosis by their laboratory data. Thus, when radiologists encounter these CT findings of pharyngitis that is not alleviated by antibiotic therapy, infectious mononucleosis should be considered in the differential diagnosis.

  13. Diagnosing neuroleukemiosis: Is there a role for 18F-FDG-PET/CT?

    PubMed

    Sabaté-Llobera, A; Cortés-Romera, M; Gamundí-Grimalt, E; Sánchez-Fernández, J J; Rodríguez-Bel, L; Gámez-Cenzano, C

    An imaging case is presented on a patient referred to our department for an 18 F-FDG-PET/CT, as a paraneoplastic syndrome was suspected due to his clinical situation. He had a history of acute myeloid leukemia (AML) treated two years earlier, with sustained complete remission to date. 18 F-FDG-PET/CT findings revealed hypermetabolism in almost all nerve roots, suggesting meningeal spread, consistent with the subsequent MRI findings. Cerebrospinal fluid (CSF) findings confirmed a leptomeningeal reactivation of AML. Although not many studies have evaluated the role of 18 F-FDG-PET/CT in leukemia, it is a noninvasive tool for detecting extramedullary sites of disease and a good imaging alternative for those patients on whom an MRI cannot be performed. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. Clinicopathological characteristics including BRAF V600E mutation status and PET/CT findings in papillary thyroid carcinoma.

    PubMed

    Choi, Eun Kyoung; Chong, Ari; Ha, Jung-Min; Jung, Chan Kwon; O, Joo Hyun; Kim, Sung Hoon

    2017-07-01

    We assessed the associations between FDG uptake in primary papillary thyroid carcinomas (PTCs) and clinicopathological features, including the BRAF V600E mutation, using quantitative and qualitative analyses of preoperative PET/CT data. This was a retrospective review of 106 patients with PTC who underwent PET/CT scans between February 2009 and January 2011 before undergoing total thyroidectomy. Data collected from surgical specimens were compared with FDG uptake in the primary tumour using quantitative and qualitative analyses of preoperative PET/CT data. Clinicopathological data included the primary tumour size, subtype, capsular invasion, extrathyroid extension, multifocality, BRAF V600E mutation status, lymph node metastasis and distant metastasis. The SUVmax of the primary tumour was significantly higher in patients with a primary tumour >1 cm, extrathyroid extension or the BRAF V600E mutation than in patients without these features (P<.001, .049 and <.001). Univariate analyses showed that primary tumour size, extrathyroid extension and BRAF V600E mutation status were associated with the SUVmax of the PTC. Multivariate analysis indicated that primary tumour size and the BRAF V600E mutation were associated with the SUVmax of the PTC. In a visual assessment, the primary tumour size was larger in FDG-avid than in non-FDG-avid PTCs (P<.001). There was no significant difference in the presence of multifocality, thyroid capsular invasion, extrathyroid extension, BRAF V600E mutation, lymph node metastasis or distant metastasis between FDG-avid and non-FDG-avid PTCs. Primary tumour size and the BRAF V600E mutation are significant factors associated with the SUVmax on preoperative PET/CT in patients with PTC. © 2017 John Wiley & Sons Ltd.

  15. Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study.

    PubMed

    Morawiec, Beata; Fournier, Stephane; Tapponnier, Maxime; Prior, John O; Monney, Pierre; Dunet, Vincent; Lauriers, Nathalie; Recordon, Frederique; Trana, Catalina; Iglesias, Juan-Fernando; Kawecki, Damian; Boulat, Olivier; Bardy, Daniel; Lamsidri, Sabine; Eeckhout, Eric; Hugli, Olivier; Muller, Olivier

    2017-07-10

    Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. ClinicalTrials.gov Identifier: NCT01374607. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  16. Endoscopic Complete Remission of Crohn Disease After Anti-Tumor Necrosis Factor-α Therapy: CT Enterographic Findings and Their Clinical Implications.

    PubMed

    Kim, Cherry; Park, Seong Ho; Yang, Suk-Kyun; Ye, Byong Duk; Park, Sang Hyoung; Lee, Jong Seok; Kim, Hyun Jin; Kim, Ah Young; Ha, Hyun Kwon

    2016-06-01

    The purpose of this study was to describe the CT enterographic (CTE) findings after endoscopic complete remission (CR) of Crohn disease in patients treated with anti-tumor necrosis factor-α (anti-TNF-α) and the clinical implications of these findings. The records of 27 patients with Crohn disease (14 men, 13 women; mean age, 28.4 ± 8.6 [SD] years) who achieved endoscopic (ileocolonoscopic) CR after anti-TNF-α therapy and underwent CTE both before therapy and at endoscopic CR were identified. Two readers independently assessed the frequencies and severities of mural and perienteric CTE abnormalities, generally regarded as active inflammatory findings, in the terminal ileum and colorectum in the endoscopic CR state and compared them with the corresponding findings before anti-TNF-α therapy. The association between the presence of CTE abnormalities in the face of endoscopic CR and patient outcome during subsequent follow-up was investigated. CTE abnormalities were present in the face of endoscopic CR in 11-18 (26-42%) of 43 bowel sections (18 terminal ileum, 25 colorectum), the most frequent being mural hyperenhancement (21-40%) followed by mural thickening (12-16%). Both findings were mild and unaccompanied by other findings. The frequency and severity of mural and perienteric CTE abnormalities were statistically significantly reduced at endoscopic CR compared with the pre-treatment state. Patients with (n = 10) and without (n = 17) CTE abnormalities at endoscopic CR did not significantly differ with respect to Crohn disease aggravation during subsequent follow-up periods averaging 27.4 and 28.5 months (0/10 versus 2/17, p = 0.516). More than one-fourth of bowel sections in endoscopic CR after anti-TNF-α therapy had residual CTE abnormalities, predominantly mild mural thickening or hyperenhancement. These findings may not have any clinical significance.

  17. Imaging Findings of Ulceroglandular Tularemia

    PubMed Central

    Anand, Neil; Deochand, Osmani; Murphy, Robyn

    2017-01-01

    Francisella tularensis, the causative organism in Tularemia, is a relatively rare disease. There are a few radiological clues to elucidate its presence when suspicion arises. There should be strong consideration for Tularemia in the differential of any patient with its classic symptoms, diffuse cervical lymphadenopathy with evidence of necrosis, and enlarged adenoids. Ultrasound may demonstrate suppurative lymphadenopathy suggestive of infection, as in the case presented. CT often will demonstrate the extent of lymphadenopathy. On chest radiography, tularemia pneumonia is often the presenting finding, which may demonstrate bilateral or lobar infiltrates. Additionally, hilar lymphadenopathy and pleural effusions are often associated findings. Cavitary lesions may be present, which are better delineated on CT scan. We present a case of a 7-year-old male who presented with a painful right-sided palpable neck mass for 9 days, who was diagnosed with Tularemia after numerous admissions. PMID:28580063

  18. CT imaging spectrum of infiltrative renal diseases.

    PubMed

    Ballard, David H; De Alba, Luis; Migliaro, Matias; Previgliano, Carlos H; Sangster, Guillermo P

    2017-11-01

    Most renal lesions replace the renal parenchyma as a focal space-occupying mass with borders distinguishing the mass from normal parenchyma. However, some renal lesions exhibit interstitial infiltration-a process that permeates the renal parenchyma by using the normal renal architecture for growth. These infiltrative lesions frequently show nonspecific patterns that lead to little or no contour deformity and have ill-defined borders on CT, making detection and diagnosis challenging. The purpose of this pictorial essay is to describe the CT imaging findings of various conditions that may manifest as infiltrative renal lesions.

  19. Predicting tumor hypoxia in non-small cell lung cancer by combining CT, FDG PET and dynamic contrast-enhanced CT.

    PubMed

    Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter

    2017-11-01

    Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The

  20. Elucidating early CT after pancreatico-duodenectomy: a primer for radiologists.

    PubMed

    Tonolini, Massimo; Ierardi, Anna Maria; Carrafiello, Gianpaolo

    2018-04-13

    Pancreatico-duodenectomy (PD) represents the standard surgical treatment for resectable malignancies of the pancreatic head, distal common bile duct, periampullary region and duodenum, and is also performed to manage selected benign tumours and refractory chronic pancreatitis. Despite improved surgical techniques and acceptable mortality, PD remains a technically demanding, high-risk operation burdened with high morbidity (complication rates 40-50% of patients). Multidetector computed tomography (CT) represents the mainstay modality to rapidly investigate the postoperative abdomen, and to provide a consistent basis for an appropriate choice between conservative, interventional or surgical treatment. However, radiologists require familiarity with the surgically altered anatomy, awareness of expected imaging appearances and possible complications to correctly interpret early post-PD CT studies. This paper provides an overview of surgical indications and techniques, discusses risk factors and clinical manifestations of the usual postsurgical complications, and suggests appropriate techniques and indications for early postoperative CT imaging. Afterwards, the usual, normal early post-PD CT findings are presented, including transient fluid, pneumobilia, delayed gastric emptying, identification of pancreatic gland remnant and of surgical anastomoses. Finally, several imaging examples review the most common and some unusual complications such as pancreatic fistula, bile leaks, abscesses, intraluminal and extraluminal haemorrhage, and acute pancreatitis. • Pancreatico-duodenectomy (PD) is a technically demanding surgery burdened with high morbidity (40-50%). • Multidetector CT is the mainstay technique to investigate suspected complications following PD. • Interpreting post-PD CT requires knowledge of surgically altered anatomy and expected findings. • CT showing collection at surgical site supports clinico-biological diagnosis of pancreatic fistula. • Other

  1. Novel CT-based objective imaging biomarkers of long term radiation-induced lung damage.

    PubMed

    Veiga, Catarina; Landau, David; Devaraj, Anand; Doel, Tom; White, Jared; Ngai, Yenting; Hawkes, David J; McClelland, Jamie R

    2018-06-14

    and Purpose: Recent improvements in lung cancer survival have spurred an interest in understanding and minimizing long term radiation-induced lung damage (RILD). However, there is still no objective criteria to quantify RILD leading to variable reporting across centres and trials. We propose a set of objective imaging biomarkers to quantify common radiological findings observed 12-months after lung cancer radiotherapy (RT). Baseline and 12-month CT scans of 27 patients from a phase I/II clinical trial of isotoxic chemoradiation were included in this study. To detect and measure the severity of RILD, twelve quantitative imaging biomarkers were developed. These describe basic CT findings including parenchymal change, volume reduction and pleural change. The imaging biomarkers were implemented as semi-automated image analysis pipelines and assessed against visual assessment of the occurrence of each change. The majority of the biomarkers were measurable in each patient. Their continuous nature allows objective scoring of severity for each patient. For each imaging biomarker the cohort was split into two groups according to the presence or absence of the biomarker by visual assessment, testing the hypothesis that the imaging biomarkers were different in these two groups. All features were statistically significant except for rotation of the main bronchus and diaphragmatic curvature. The majority of the biomarkers were not strongly correlated with each other suggesting that each of the biomarkers is measuring a separate element of RILD pathology. We developed objective CT-based imaging biomarkers that quantify the severity of radiological lung damage after RT. These biomarkers are representative of typical radiological findings of RILD. Copyright © 2018. Published by Elsevier Inc.

  2. Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging.

    PubMed

    Michalak, Gregory; Grimes, Joshua; Fletcher, Joel; Halaweish, Ahmed; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia

    2016-01-01

    The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. The authors' report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.

  3. Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michalak, Gregory; Grimes, Joshua; Fletcher, Joel

    2016-01-15

    Purpose: The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Methods: Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kVmore » beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Results: Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. Conclusions: The authors’ report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.« less

  4. Sensitivity and specificity of CT- and MRI-scanning in evaluation of occult fracture of the proximal femur.

    PubMed

    Haubro, M; Stougaard, C; Torfing, T; Overgaard, S

    2015-08-01

    To estimate sensitivity and specificity of CT and MRI examinations in patients with fractures of the proximal femur. To determine the interobserver agreement of the modalities among a senior consulting radiologist, a resident in radiology and a resident in orthopaedics surgery. 67 patients (27 males, 40 females, mean age 80.5) seen in the emergency room with hip pain after fall, inability to stand and a primary X-ray without fracture were evaluated with both CT and MRI. The images were analysed by a senior consulting musculoskeletal radiologist, a resident in radiology and a resident in orthopaedic surgery. Sensitivity and specificity were estimated with MRI as the golden standard. Kappa value was used to assess level of agreement in both MRI and CT finding. 15 fractures of the proximal femur were found (7 intertrochanteric-, 3 femoral neck and 5 fractures of the greater trochanter). Two fractures were not identified by CT and four changed fracture location. Among those, three patients underwent surgery. Sensitivity of CT was 0.87; 95% CI [0.60; 0.98]. Kappa for interobserver agreement for CT were 0.46; 95% CI [0.23; 0.76] and 0.67; 95% CI [0.42; 0.90]. For MRI 0.67; 95% CI [0.43; 0.91] and 0.69; 95% CI [0.45; 0.92]. MRI was observed to have a higher diagnostic accuracy than CT in detecting occult fractures of the hip. Interobserver analysis showed high kappa values corresponding substantial agreement in both CT and MRI. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Imaging in blunt cardiac injury: Computed tomographic findings in cardiac contusion and associated injuries.

    PubMed

    Hammer, Mark M; Raptis, Demetrios A; Cummings, Kristopher W; Mellnick, Vincent M; Bhalla, Sanjeev; Schuerer, Douglas J; Raptis, Constantine A

    2016-05-01

    Blunt cardiac injury (BCI) may manifest as cardiac contusion or, more rarely, as pericardial or myocardial rupture. Computed tomography (CT) is performed in the vast majority of blunt trauma patients, but the imaging features of cardiac contusion are not well described. To evaluate CT findings and associated injuries in patients with clinically diagnosed BCI. We identified 42 patients with blunt cardiac injury from our institution's electronic medical record. Clinical parameters, echocardiography results, and laboratory tests were recorded. Two blinded reviewers analyzed chest CTs performed in these patients for myocardial hypoenhancement and associated injuries. CT findings of severe thoracic trauma are commonly present in patients with severe BCI; 82% of patients with ECG, cardiac enzyme, and echocardiographic evidence of BCI had abnormalities of the heart or pericardium on CT; 73% had anterior rib fractures, and 64% had pulmonary contusions. Sternal fractures were only seen in 36% of such patients. However, myocardial hypoenhancement on CT is poorly sensitive for those patients with cardiac contusion: 0% of right ventricular contusions and 22% of left ventricular contusions seen on echocardiography were identified on CT. CT signs of severe thoracic trauma are frequently present in patients with severe BCI and should be regarded as indirect evidence of potential BCI. Direct CT findings of myocardial contusion, i.e. myocardial hypoenhancement, are poorly sensitive and should not be used as a screening tool. However, some left ventricular contusions can be seen on CT, and these patients could undergo echocardiography or cardiac MRI to evaluate for wall motion abnormalities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Serial changes and prognostic implications of CT findings in combined pulmonary fibrosis and emphysema: comparison with fibrotic idiopathic interstitial pneumonias alone.

    PubMed

    Lee, Geewon; Kim, Ki Uk; Lee, Ji Won; Suh, Young Ju; Jeong, Yeon Joo

    2017-05-01

    Background Although fibrotic idiopathic interstitial pneumonias (IIPs) alone and those combined with pulmonary emphysema are naturally progressive diseases, the process of deterioration and outcomes are variable. Purpose To evaluate and compare serial changes of computed tomography (CT) abnormalities and prognostic predictive factors in fibrotic IIPs alone and those combined with pulmonary emphysema. Material and Methods A total of 148 patients with fibrotic IIPs alone (82 patients) and those combined with pulmonary emphysema (66 patients) were enrolled. Semi-quantitative CT analysis was used to assess the extents of CT characteristics which were evaluated on initial and follow-up CT images. Univariate and multivariate analyses were performed to assess the effects of clinical and CT variables on survival. Results Significant differences were noted between fibrotic scores, as determined using initial CT scans, in the fibrotic IIPs alone (21.22 ± 9.83) and those combined with pulmonary emphysema groups (14.70 ± 7.28) ( P < 0.001). At follow-up CT scans, changes in the extent of ground glass opacities (GGO) were greater ( P = 0.031) and lung cancer was more prevalent ( P = 0.001) in the fibrotic IIPs combined with pulmonary emphysema group. Multivariate Cox proportional hazards analysis showed changes in the extent of GGO (hazard ratio, 1.056) and the presence of lung cancer (hazard ratio, 4.631) were predictive factors of poor survivals. Conclusion Although patients with fibrotic IIPs alone and those combined with pulmonary emphysema have similar mortalities, lung cancer was more prevalent in patients with fibrotic IIPs combined with pulmonary emphysema. Furthermore, changes in the extent of GGO and the presence of lung cancer were independent prognostic factors of poor survivals.

  7. Optimizing the balance between radiation dose and image quality in pediatric head CT: findings before and after intensive radiologic staff training.

    PubMed

    Paolicchi, Fabio; Faggioni, Lorenzo; Bastiani, Luca; Molinaro, Sabrina; Puglioli, Michele; Caramella, Davide; Bartolozzi, Carlo

    2014-06-01

    The purpose of this study was to assess the radiation dose and image quality of pediatric head CT examinations before and after radiologic staff training. Outpatients 1 month to 14 years old underwent 215 unenhanced head CT examinations before and after intensive training of staff radiologists and technologists in optimization of CT technique. Patients were divided into three age groups (0-4, 5-9, and 10-14 years), and CT dose index, dose-length product, tube voltage, and tube current-rotation time product values before and after training were retrieved from the hospital PACS. Gray matter conspicuity and contrast-to-noise ratio before and after training were calculated, and subjective image quality in terms of artifacts, gray-white matter differentiation, noise, visualization of posterior fossa structures, and need for repeat CT examination was visually evaluated by three neuroradiologists. The median CT dose index and dose-length product values were significantly lower after than before training in all age groups (27 mGy and 338 mGy ∙ cm vs 107 mGy and 1444 mGy ∙ cm in the 0- to 4-year-old group, 41 mGy and 483 mGy ∙ cm vs 68 mGy and 976 mGy ∙ cm in the 5- to 9-year-old group, and 51 mGy and 679 mGy ∙ cm vs 107 mGy and 1480 mGy ∙ cm in the 10- to 14-year-old group; p < 0.001). The tube voltage and tube current-time values after training were significantly lower than the levels before training (p < 0.001). Subjective posttraining image quality was not inferior to pretraining levels for any item except noise (p < 0.05), which, however, was never diagnostically unacceptable. Radiologic staff training can be effective in reducing radiation dose while preserving diagnostic image quality in pediatric head CT examinations.

  8. Multi-detector thoracic CT findings in cerebro-costo-mandibular syndrome: rib gaps and failure of costo-vertebral separation.

    PubMed

    Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan

    2014-02-01

    Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.

  9. Unipedal Diagnostic Lymphangiography Followed by Sequential CT Examinations in Patients With Idiopathic Chyluria: A Retrospective Study.

    PubMed

    Dong, Jian; Xin, Jianfeng; Shen, Wenbin; Chen, Xiaobai; Wen, Tingguo; Zhang, Chunyan; Wang, Rengui

    2018-04-01

    The objective of our study was to investigate the clinical value of diagnostic lymphangiography followed by sequential CT examinations in patients with idiopathic chyluria. Thirty-six patients with idiopathic chyluria underwent unipedal diagnostic lymphangiography and then underwent sequential CT examinations. The examinations were reviewed separately by two radiologists. Abnormal distribution of contrast medium, lymphourinary leakages, and retrograde flow were noted, and the range and distribution of lymphatic vessel lesions were recorded. The stage of idiopathic chyluria based on CT findings and the stage based on clinical findings were compared. Therapeutic management and follow-up were recorded. Statistical analyses were performed. Compared with CT studies performed after lymphangiography, diagnostic lymphangiography showed a unique capability to depict lymphourinary leakages in three patients. Lymphourinary fistulas and abnormal dilated lymphatic vessels were found in and around kidney in all patients. CT depicted retrograde flow of lymph fluid in 47.2% of patients. The consistency in staging chyluria based on CT findings and clinical findings was fair (κ = 0.455). Twenty-nine patients underwent conservative therapy, and seven underwent surgery. Surgical therapy was superior to conservative management (no recurrence, 85.7% of patients who underwent surgery vs 62.1% of patients who underwent conservative therapy; p = 0.025). From assessing the drainage of contrast medium on unipedal diagnostic lymphangiography and the redistribution of contrast medium on sequential CT examinations, it is possible to detect the existence of lymphourinary fistulas, the precise location of lymphatic anomalies, the distribution of collateral lymphatic vessels, and hydrodynamic pressure abnormality in the lymph circulation in patients with idiopathic chyluria. CT staging of chyluria provides additional information that can be used to guide therapeutic management.

  10. Chest CT scanning for clinical suspected thoracic aortic dissection: beware the alternate diagnosis.

    PubMed

    Thoongsuwan, Nisa; Stern, Eric J

    2002-11-01

    The aim of the study was retrospectively to evaluate the spectrum of chest diseases in patients presenting with clinical suspicion of thoracic aortic dissection in the emergency department. We performed a retrospective medical records review of 86 men and 44 women (ages ranging between 23 and 106 years) with clinically suspected aortic dissection, for CT scan findings and final clinical diagnoses dating between January 1996 and September 2001. All images were obtained by using a standard protocol for aortic dissection. We found aortic dissection in 32 patients (24.6%), 22 of which were Stanford classification type A and 10 Stanford type B. In 70 patients (53.9%), chest pain could not be explained by the CT scan findings. However, in 28 patients (21.5%), CT scanning did reveal an alternate diagnosis that, along with the clinical impression, probably explained the patients' presenting symptoms, including: hiatal hernia (7), pneumonia (5), intrathoracic mass (4), pericardial effusion/hemopericardium (3), esophageal mass/rupture (2), aortic aneurysm without dissection (2), pulmonary embolism (2), pleural effusion (1), aortic rupture (1), and pancreatitis (1). In cases where there is clinical suspicion of aortic dissection, CT scan findings of an alternate diagnosis for the presenting symptoms are only slightly less common than the finding of aortic dissection itself. Although the spectrum of findings will vary depending upon your patient population, beware the alternate diagnosis.

  11. Precision analysis of a quantitative CT liver surface nodularity score.

    PubMed

    Smith, Andrew; Varney, Elliot; Zand, Kevin; Lewis, Tara; Sirous, Reza; York, James; Florez, Edward; Abou Elkassem, Asser; Howard-Claudio, Candace M; Roda, Manohar; Parker, Ellen; Scortegagna, Eduardo; Joyner, David; Sandlin, David; Newsome, Ashley; Brewster, Parker; Lirette, Seth T; Griswold, Michael

    2018-04-26

    To evaluate precision of a software-based liver surface nodularity (LSN) score derived from CT images. An anthropomorphic CT phantom was constructed with simulated liver containing smooth and nodular segments at the surface and simulated visceral and subcutaneous fat components. The phantom was scanned multiple times on a single CT scanner with adjustment of image acquisition and reconstruction parameters (N = 34) and on 22 different CT scanners from 4 manufacturers at 12 imaging centers. LSN scores were obtained using a software-based method. Repeatability and reproducibility were evaluated by intraclass correlation (ICC) and coefficient of variation. Using abdominal CT images from 68 patients with various stages of chronic liver disease, inter-observer agreement and test-retest repeatability among 12 readers assessing LSN by software- vs. visual-based scoring methods were evaluated by ICC. There was excellent repeatability of LSN scores (ICC:0.79-0.99) using the CT phantom and routine image acquisition and reconstruction parameters (kVp 100-140, mA 200-400, and auto-mA, section thickness 1.25-5.0 mm, field of view 35-50 cm, and smooth or standard kernels). There was excellent reproducibility (smooth ICC: 0.97; 95% CI 0.95, 0.99; CV: 7%; nodular ICC: 0.94; 95% CI 0.89, 0.97; CV: 8%) for LSN scores derived from CT images from 22 different scanners. Inter-observer agreement for the software-based LSN scoring method was excellent (ICC: 0.84; 95% CI 0.79, 0.88; CV: 28%) vs. good for the visual-based method (ICC: 0.61; 95% CI 0.51, 0.69; CV: 43%). Test-retest repeatability for the software-based LSN scoring method was excellent (ICC: 0.82; 95% CI 0.79, 0.84; CV: 12%). The software-based LSN score is a quantitative CT imaging biomarker with excellent repeatability, reproducibility, inter-observer agreement, and test-retest repeatability.

  12. The cutting edge - Micro-CT for quantitative toolmark analysis of sharp force trauma to bone.

    PubMed

    Norman, D G; Watson, D G; Burnett, B; Fenne, P M; Williams, M A

    2018-02-01

    Toolmark analysis involves examining marks created on an object to identify the likely tool responsible for creating those marks (e.g., a knife). Although a potentially powerful forensic tool, knife mark analysis is still in its infancy and the validation of imaging techniques as well as quantitative approaches is ongoing. This study builds on previous work by simulating real-world stabbings experimentally and statistically exploring quantitative toolmark properties, such as cut mark angle captured by micro-CT imaging, to predict the knife responsible. In Experiment 1 a mechanical stab rig and two knives were used to create 14 knife cut marks on dry pig ribs. The toolmarks were laser and micro-CT scanned to allow for quantitative measurements of numerous toolmark properties. The findings from Experiment 1 demonstrated that both knives produced statistically different cut mark widths, wall angle and shapes. Experiment 2 examined knife marks created on fleshed pig torsos with conditions designed to better simulate real-world stabbings. Eight knives were used to generate 64 incision cut marks that were also micro-CT scanned. Statistical exploration of these cut marks suggested that knife type, serrated or plain, can be predicted from cut mark width and wall angle. Preliminary results suggest that knives type can be predicted from cut mark width, and that knife edge thickness correlates with cut mark width. An additional 16 cut marks walls were imaged for striation marks using scanning electron microscopy with results suggesting that this approach might not be useful for knife mark analysis. Results also indicated that observer judgements of cut mark shape were more consistent when rated from micro-CT images than light microscopy images. The potential to combine micro-CT data, medical grade CT data and photographs to develop highly realistic virtual models for visualisation and 3D printing is also demonstrated. This is the first study to statistically explore simulated

  13. Dynamic contrast enhanced CT in nodule characterization: How we review and report.

    PubMed

    Qureshi, Nagmi R; Shah, Andrew; Eaton, Rosemary J; Miles, Ken; Gilbert, Fiona J

    2016-07-18

    Incidental indeterminate solitary pulmonary nodules (SPN) that measure less than 3 cm in size are an increasingly common finding on computed tomography (CT) worldwide. Once identified there are a number of imaging strategies that can be performed to help with nodule characterization. These include interval CT, dynamic contrast enhanced computed tomography (DCE-CT), (18)F-fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET-CT). To date the most cost effective and efficient non-invasive test or combination of tests for optimal nodule characterization has yet to be determined.DCE-CT is a functional test that involves the acquisition of a dynamic series of images of a nodule before and following the administration of intravenous iodinated contrast medium. This article provides an overview of the current indications and limitations of DCE- CT in nodule characterization and a systematic approach to how to perform, analyse and interpret a DCE-CT scan.

  14. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis.

    PubMed

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a "routine" PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures.

  15. Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

    PubMed

    Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut

    2018-06-07

    arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.

  16. Comparison of (11)C-4'-thiothymidine, (11)C-methionine, and (18)F-FDG PET/CT for the detection of active lesions of multiple myeloma.

    PubMed

    Okasaki, Momoko; Kubota, Kazuo; Minamimoto, Ryogo; Miyata, Yoko; Morooka, Miyako; Ito, Kimiteru; Ishiwata, Kiichi; Toyohara, Jun; Inoue, Tomio; Hirai, Risen; Hagiwara, Shotaro; Miwa, Akiyoshi

    2015-04-01

    The aims of this study were to evaluate the possibility of using (11)C-methionine ((11)C-MET) and (11)C-4'-thiothymidine ((11)C-4DST) whole-body PET/CT for the imaging of amino acid metabolism and DNA synthesis, respectively, when searching for bone marrow involvement in patients with multiple myeloma (MM) and to compare these findings with those for (18)F-FDG PET/CT and aspiration cytology. A total of 64 patients with MM, solitary plasmacytoma, monoclonal gammopathy of undetermined significance, or an unspecified diagnosis were prospectively enrolled. All the patients underwent three whole-body PET/CT examinations within a period of 1 week. First, the tracer accumulation was visually evaluated as positive, equivocal, or negative for 55 focal lytic lesions visualized using CT in 24 patients. Second, the percentages of marrow plasma cells as calculated using a bone marrow aspiration smear and tracer accumulation were evaluated in the posterior iliac crests of 36 patients. Among the 55 lytic lesions, the (11)C-MET and (11)C-4DST findings tended to reveal more positive findings than the (18)F-FDG findings. Based on the standard criteria for the diagnosis of active myeloma using the percentage of marrow plasma cells, significant differences were found between the (18)F-FDG and (11)C-MET findings and between the (18)F-FDG and (11)C-4DST findings, but no significant difference was observed between the (11)C-MET and (11)C-4DST findings. The addition of (11)C-MET and (11)C-4DST to (18)F-FDG when performing PET/CT enabled clearer evaluations of equivocal lesions. Based on cytological diagnostic criteria, (11)C-MET and (11)C-4DST were more sensitive than (18)F-FDG for the detection of active lesions. (11)C-MET and (11)C-4DST were more useful than (18)F-FDG for the detection of active lesions, especially during the early stage of disease.

  17. Helical 4D CT and Comparison with Cine 4D CT

    NASA Astrophysics Data System (ADS)

    Pan, Tinsu

    4D CT was one of the most important developments in radiation oncology in the last decade. Its early development in single slice CT and commercialization in multi-slice CT has radically changed our practice in radiation treatment of lung cancer, and has enabled the stereotactic radiosurgery of early stage lung cancer. In this chapter, we will document the history of 4D CT development, detail the data sufficiency condition governing the 4D CT data collection; present the design of the commercial helical 4D CTs from Philips and Siemens; compare the differences between the helical 4D CT and the GE cine 4D CT in data acquisition, slice thickness, acquisition time and work flow; review the respiratory monitoring devices; and understand the causes of image artifacts in 4D CT.

  18. The Rh=ct universe

    NASA Astrophysics Data System (ADS)

    Melia, F.; Shevchuk, A. S. H.

    2012-01-01

    The backbone of standard cosmology is the Friedmann-Robertson-Walker solution to Einstein's equations of general relativity (GR). In recent years, observations have largely confirmed many of the properties of this model, which are based on a partitioning of the universe's energy density into three primary constituents: matter, radiation and a hypothesized dark energy which, in Λ cold dark matter (ΛCDM), is assumed to be a cosmological constant Λ. Yet with this progress, several unpalatable coincidences (perhaps even inconsistencies) have emerged along with the successful confirmation of expected features. One of these is the observed equality of our gravitational horizon Rh(t0) with the distance ct0 light has travelled since the big bang, in terms of the current age t0 of the universe. This equality is very peculiar because it need not have occurred at all and, if it did, should only have happened once (right now) in the context of ΛCDM. In this paper, we propose an explanation for why this equality may actually be required by GR, through the application of Birkhoff's theorem and the Weyl postulate, at least in the case of a flat space-time. If this proposal is correct, Rh(t) should be equal to ct for all cosmic time t, not just its present value t0. Therefore, models such as ΛCDM would be incomplete because they ascribe the cosmic expansion to variable conditions not consistent with this relativistic constraint. We show that this may be the reason why the observed galaxy correlation function is not consistent with the predictions of the standard model. We suggest that an Rh=ct universe is easily distinguishable from all other models at large redshift (i.e. in the early universe), where the latter all predict a rapid deceleration.

  19. Musculoskeletal Imaging Findings of Hematologic Malignancies.

    PubMed

    Navarro, Shannon M; Matcuk, George R; Patel, Dakshesh B; Skalski, Matthew; White, Eric A; Tomasian, Anderanik; Schein, Aaron J

    2017-01-01

    Hematologic malignancies comprise a set of prevalent yet clinically diverse diseases that can affect every organ system. Because blood components originate in bone marrow, it is no surprise that bone marrow is a common location for both primary and metastatic hematologic neoplasms. Findings of hematologic malignancy can be seen with most imaging modalities including radiography, computed tomography (CT), technetium 99m ( 99m Tc) methylene diphosphonate (MDP) bone scanning, fluorine 18 ( 18 F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT, and magnetic resonance (MR) imaging. Because of the diversity of imaging appearances and clinical behavior of this spectrum of disease, diagnosis can be challenging, and profound understanding of the underlying pathophysiologic changes and current treatment modalities can be daunting. The appearance of normal bone marrow at MR imaging and FDG PET/CT is also varied due to dynamic compositional changes with normal aging and in response to hematologic demand or treatment, which can lead to false-positive interpretation of imaging studies. In this article, the authors review the normal maturation and imaging appearance of bone marrow. Focusing on lymphoma, leukemia, and multiple myeloma, they present the spectrum of imaging findings of hematologic malignancy affecting the musculoskeletal system and the current imaging tools available to the radiologist. They discuss the imaging findings of posttreatment bone marrow and review commonly used staging systems and consensus recommendations for appropriate imaging for staging, management, and assessment of clinical remission. © RSNA, 2017.

  20. Contrast Enhancement of the Right Ventricle during Coronary CT Angiography--Is It Necessary?

    PubMed

    Kok, Madeleine; Kietselaer, Bas L J H; Mihl, Casper; Altintas, Sibel; Nijssen, Estelle C; Wildberger, Joachim E; Das, Marco

    2015-01-01

    It is unclear if prolonged contrast media injection, to improve right ventricular visualization during coronary CT angiography, leads to increased detection of right ventricle pathology. The purpose of this study was to evaluate right ventricle enhancement and subsequent detection of right ventricle disease during coronary CT angiography. 472 consecutive patients referred for screening coronary CT angiography were retrospectively evaluated. Every patient underwent multidetector-row CT of the coronary arteries: 128x 0.6mm coll., 100-120kV, rot. time 0.28s, ref. mAs 350 and received an individualized (P3T) contrast bolus injection of iodinated contrast medium (300 mgI/ml). Patient data were analyzed to assess right ventricle enhancement (HU) and right ventricle pathology. Image quality was defined good when right ventricle enhancement >200HU, moderate when 140-200HU and poor when <140HU. Good image quality was found in 372 patients, moderate in 80 patients and poor in 20 patients. Mean enhancement of the right ventricle cavity was 268HU±102. Patients received an average bolus of 108±24 ml at an average peak flow rate of 6.1±2.2 ml/s. In only three out of 472 patients (0.63%) pathology of the right ventricle was found (dilatation) No other right ventricle pathology was detected. Right ventricle pathology was detected in three out of 472 patients; the dilatation observed in these three cases may have been picked up even without dedicated enhancement of the right ventricle. Based on our findings, right ventricle enhancement can be omitted during screening coronary CT angiography.

  1. Diagnostic accuracy of sequential co-registered PET+MR in comparison to PET/CT in local thoracic staging of malignant pleural mesothelioma.

    PubMed

    Martini, Katharina; Meier, Andreas; Opitz, Isabelle; Weder, Walter; Veit-Haibach, Patrick; Stahel, Rolf A; Frauenfelder, Thomas

    2016-04-01

    To investigate the diagnostic accuracy of sequential co-registered PET+MR (PET+MR) for local staging of malignant pleural mesothelioma (MPM) compared to PET/CT. In a prospective clinical trial 34 consecutive patients (median age 66 years; range 40-79 years; 1 female, 33 male) with known MPM, who underwent PET/CT and PET+MR exams for either staging or re-staging/follow-up were evaluated. Imaging was conducted using a tri-modality PET/CT-MR set-up (Discovery PET/CT 690, 3T Discovery MR 750w, both GE Healthcare, Waukesha, WI, USA). In 26 cases histopathology served as standard of reference. Two independent readers evaluated images for T and N stage, confidence level (sure to unsure; 1-3) and subjective overall image quality (very good to non-diagnostic; 1-4). Inter-observer agreement of T and N stages (Cohen's kappa) and interclass correlation coefficient (ICC) between PET/CT vs. PET+MR was calculated. Inter observer agreement for evaluation of T and N Stage in PET/CT images was excellent (k=0.844 and k=0.824, respectively), whereas PET+MR imaging showed substantial agreement in T and N stage (k=0.729 and k=0.691, respectively). The ICC of PET/CT vs. PET+MR for evaluation of both, T and N Stage, was excellent (ICC=0.951 and ICC=0.93, respectively). Diagnostic confidence was scored significantly higher in PET+MR compared to PET/CT (mean score=1.66 and 1.93, respectively; p=0.004). Image quality was diagnostic for all image series. Comparing pT and pN stage vs cT and cN stage (n=26 cases), both imaging modalities showed excellent agreement for T stage (ICCPET+MR=0.888 vs. ICCPET/CT=0.853, respectively) and substantial to moderate agreement for N stage (ICCPET+MR=0.683 vs. ICC=0.595PET/CT, respectively). Our findings suggest that diagnostic accuracy of PET+MR is comparable to PET/CT for local staging of MPM, whereas radiologists felt significantly more confident staging PET+MR compared to PET/CT images (p=0003), using dedicated sequences. Copyright © 2016 Elsevier

  2. CT characteristics of Morel-Lavallée lesions: an under-recognized but significant finding in acute trauma imaging.

    PubMed

    McKenzie, Gavin A; Niederhauser, Blake D; Collins, Mark S; Howe, Benjamin M

    2016-08-01

    To highlight the significance and imaging characteristics of Morel-Lavallée (ML) lesions, which have been well characterized on MRI, but are potentially under-recognized on CT. Twenty-eight Morel-Lavallée lesions were identified in 18 patients and were all clinically or surgically confirmed. Lesions were grouped into acute (<3 days), subacute (3-30 days), and chronic (>30 days) at the time of CT imaging. Charts were reviewed to gather patient characteristics, injury patterns, radiologist interpretation, treatment, and outcomes. Sixteen male and 2 female patients with a mean age of 50 years (range 19-80) at the date of their initial evaluation were identified. All patients had significant trauma that accounted for 28 ML lesions, all of which were in a characteristic subcutaneous location overlying the muscular fascial plane. Lesions on CT went through an evolution from hyperdense, poorly or moderately marginated without a pseudocapsule to being hypodense, with internal fat globules or septations and well marginated with a complete enhancing pseudocapsule. Only 1 (4 %) of the ML lesions was suggested and 7 (25 %) lesions were not commented on at all by the interpreting radiologist. Morel-Lavallée lesions are post-traumatic closed, internal, soft-tissue, degloving lesions that are potentially underrecognized on CT. Most acute ML lesions are nonspecific, resembling simple hematomas or contusions. ML lesions evolve as they age with subacute and chronic lesions demonstrating the known features described on MR imaging that should allow for an accurate imaging diagnosis.

  3. Observation of the effect of targeted therapy of 64-slice spiral CT combined with cryoablation for liver cancer.

    PubMed

    Yan, Qiao-Huan; Xu, Dian-Guo; Shen, Yan-Feng; Yuan, Ding-Ling; Bao, Jun-Hui; Li, Hai-Bin; Lv, Ying-Gang

    2017-06-14

    To observe the effect of targeted therapy with 64-slice spiral computed tomography (CT) combined with cryoablation for liver cancer. A total of 124 patients (142 tumors) were enrolled into this study. According to the use of dual-slice spiral CT or 64-slice spiral CT as a guide technology, patients were divided into two groups: dual-slice group ( n = 56, 65 tumors) and 64-slice group ( n = 8, 77 tumors). All patients were accepted and received targeted therapy by an argon-helium superconducting surgery system. The guided scan times of the two groups was recorded and compared. In the two groups, the lesion ice coverage in diameter of ≥ 3 cm and < 3 cm were recorded, and freezing effective rate was compared. Hepatic perfusion values [hepatic artery perfusion (HAP), portal vein perfusion (PVP), and the hepatic arterial perfusion index (HAPI)] of tumor tissues, adjacent tissues and normal liver tissues at preoperative and postoperative four weeks in the two groups were compared. Local tumor changes were recorded and efficiency was compared at four weeks post-operation. Adverse events were recorded and compared between the two groups, including fever, pain, frostbite, nausea, vomiting, pleural effusion and abdominal bleeding. Guided scan times in the dual-slice group was longer than that in the 64-slice group ( t = 11.445, P = 0.000). The freezing effective rate for tumors < 3 cm in diameter in the dual-slice group (81.58%) was lower than that in the 64-slice group (92.86%) (χ 2 = 5.707, P = 0.017). The HAP and HAPI of tumor tissues were lower at four weeks post-treatment than at pre-treatment in both groups (all P < 0.05), and those in the 64-slice group were lower than that in the dual-slice group (all P < 0.05). HAP and PVP were lower and HAPI was higher in tumor adjacent tissues at post-treatment than at pre-treatment (all P < 0.05). Furthermore, the treatment effect and therapeutic efficacy in the dual-slice group were lower than the 64-slice group at four weeks

  4. TH-C-BRD-06: A Novel MRI Based CT Artifact Correction Method for Improving Proton Range Calculation in the Presence of Severe CT Artifacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, P; Schreibmann, E; Fox, T

    2014-06-15

    Purpose: Severe CT artifacts can impair our ability to accurately calculate proton range thereby resulting in a clinically unacceptable treatment plan. In this work, we investigated a novel CT artifact correction method based on a coregistered MRI and investigated its ability to estimate CT HU and proton range in the presence of severe CT artifacts. Methods: The proposed method corrects corrupted CT data using a coregistered MRI to guide the mapping of CT values from a nearby artifact-free region. First patient MRI and CT images were registered using 3D deformable image registration software based on B-spline and mutual information. Themore » CT slice with severe artifacts was selected as well as a nearby slice free of artifacts (e.g. 1cm away from the artifact). The two sets of paired MRI and CT images at different slice locations were further registered by applying 2D deformable image registration. Based on the artifact free paired MRI and CT images, a comprehensive geospatial analysis was performed to predict the correct CT HU of the CT image with severe artifact. For a proof of concept, a known artifact was introduced that changed the ground truth CT HU value up to 30% and up to 5cm error in proton range. The ability of the proposed method to recover the ground truth was quantified using a selected head and neck case. Results: A significant improvement in image quality was observed visually. Our proof of concept study showed that 90% of area that had 30% errors in CT HU was corrected to 3% of its ground truth value. Furthermore, the maximum proton range error up to 5cm was reduced to 4mm error. Conclusion: MRI based CT artifact correction method can improve CT image quality and proton range calculation for patients with severe CT artifacts.« less

  5. Skills of Cognitive Therapy (SoCT): A New Measure of Patients' Comprehension and Use

    ERIC Educational Resources Information Center

    Jarrett, Robin B.; Vittengl, Jeffrey R.; Clark, Lee Anna; Thase, Michael E.

    2011-01-01

    The authors describe the development and psychometric properties of a new measure called the Skills of Cognitive Therapy (SoCT) in depressed adults and their cognitive therapists. The 8-item SoCT assesses patients' understanding and use of basic cognitive therapy (CT) skills rated from the perspectives of both observers (SoCT-O; therapists in this…

  6. Silastic injection for vocal fold medialization resulting in a false-positive finding on F18 FDG-PET/CT.

    PubMed

    Mahfouz, Ayman; Naji, Meeran; Mok, Wing Yan; Taghi, Ali S; Win, Zarni

    2015-09-01

    A false-positive uptake of F18-fluorodeoxyglucose (FDG) on positron-emission tomography/computed tomography (PET/CT) can result in confusion and misinterpretation of scans. Such uptakes have been previously described after injection of polytetrafluoroethylene (Teflon) into the vocal folds. Similarly, vocal fold injection of silicone elastomer (Silastic) can result not only in a false-positive FDG uptake on PET/CT, but also in chronic inflammation. We report a case of increased FDG uptake in a vocal fold after Silastic injection that was misinterpreted as a malignancy in a 70-year-old woman who had metastatic carcinoma of the stomach.

  7. CT of inferior vena cava filters: normal presentations and potential complications.

    PubMed

    Georgiou, Nicholas A; Katz, Douglas S; Ganson, George; Eng, Kaitlin; Hon, Man

    2015-12-01

    With massive pulmonary embolism (PE) being the first or second leading cause of unexpected death in adults, protection against PE is critical in appropriately selected patients. The use of inferior vena cava (IVC) filters has increased over the years, paralleling the increased detection of deep venous thrombosis (DVT) and PE by improved and more available imaging techniques. The use of IVC filters has become very common as an alternative and/or as a supplement to anticoagulation, and these filters are often seen on routine abdominal CT, including in the emergency setting; therefore, knowledge of the normal spectrum of findings of IVC filters by the radiologist on CT is critical. Additionally, CT can be used specifically to identify complications related to IVC filters, and CT may alternatively demonstrate IVC filter-related problems which are not specifically anticipated clinically. With multiple available IVC filters on the US market, and even more available outside of the USA, it is important for the emergency and the general radiologist to recognize the different models and various appearances and positioning on CT, as well as their potential complications. These complications may be related to venous access, but also include thrombosis related to the filter, filter migration and penetration, and problems associated with filter deployment. With the increasing number of inferior vena cava filters placed and their duration within patients increasing over time, it is critical for emergency and other radiologists to be aware of these findings on CT.

  8. Pancreatic mucinous cystic neoplasm size using CT volumetry, spherical and ellipsoid formulas: validation study.

    PubMed

    Chalian, Hamid; Seyal, Adeel Rahim; Rezai, Pedram; Töre, Hüseyin Gürkan; Miller, Frank H; Bentrem, David J; Yaghmai, Vahid

    2014-01-10

    The accuracy for determining pancreatic cyst volume with commonly used spherical and ellipsoid methods is unknown. The role of CT volumetry in volumetric assessment of pancreatic cysts needs to be explored. To compare volumes of the pancreatic cysts by CT volumetry, spherical and ellipsoid methods and determine their accuracy by correlating with actual volume as determined by EUS-guided aspiration. Setting This is a retrospective analysis performed at a tertiary care center. Patients Seventy-eight pathologically proven pancreatic cysts evaluated with CT and endoscopic ultrasound (EUS) were included. Design The volume of fourteen cysts that had been fully aspirated by EUS was compared to CT volumetry and the routinely used methods (ellipsoid and spherical volume). Two independent observers measured all cysts using commercially available software to evaluate inter-observer reproducibility for CT volumetry. The volume of pancreatic cysts as determined by various methods was compared using repeated measures analysis of variance. Bland-Altman plot and intraclass correlation coefficient were used to determine mean difference and correlation between observers and methods. The error was calculated as the percentage of the difference between the CT estimated volumes and the aspirated volume divided by the aspirated one. CT volumetry was comparable to aspirated volume (P=0.396) with very high intraclass correlation (r=0.891, P<0.001) and small mean difference (0.22 mL) and error (8.1%). Mean difference with aspirated volume and error were larger for ellipsoid (0.89 mL, 30.4%; P=0.024) and spherical (1.73 mL, 55.5%; P=0.004) volumes than CT volumetry. There was excellent inter-observer correlation in volumetry of the entire cohort (r=0.997, P<0.001). CT volumetry is accurate and reproducible. Ellipsoid and spherical volume overestimate the true volume of pancreatic cysts.

  9. Comprehensive CT Evaluation in Acute Ischemic Stroke: Impact on Diagnosis and Treatment Decisions

    PubMed Central

    Löve, Askell; Siemund, Roger; Andsberg, Gunnar; Cronqvist, Mats; Holtås, Stig; Björkman-Burtscher, Isabella

    2011-01-01

    Background. With modern CT imaging a comprehensive overview of cerebral macro- and microcirculation can be obtained within minutes in acute ischemic stroke. This opens for patient stratification and individualized treatment. Methods. Four patients with acute ischemic stroke of different aetiologies and/or treatments were chosen for illustration of the comprehensive CT protocol and its value in subsequent treatment decisions. The patients were clinically evaluated according to the NIHSS-scale, examined with the comprehensive CT protocol including both CT angiography and CT perfusion, and followed up by MRI. Results. The comprehensive CT examination protocol increased the examination time but did not delay treatment initiation. In some cases CT angiography revealed the cause of stroke while CT perfusion located and graded the perfusion defect with reasonable accuracy, confirmed by follow-up MR-diffusion. In the presented cases findings of the comprehensive CT examination influenced the treatment strategy. Conclusions. The comprehensive CT examination is a fast and safe method allowing accurate diagnosis and making way for individualized treatment in acute ischemic stroke. PMID:21603175

  10. Worsening respiratory function in mechanically ventilated intensive care patients: feasibility and value of xenon-enhanced dual energy CT.

    PubMed

    Hoegl, Sandra; Meinel, Felix G; Thieme, Sven F; Johnson, Thorsten R C; Eickelberg, Oliver; Zwissler, Bernhard; Nikolaou, Konstantin

    2013-03-01

    To evaluate the feasibility and incremental diagnostic value of xenon-enhanced dual-energy CT in mechanically ventilated intensive care patients with worsening respiratory function. The study was performed in 13 mechanically ventilated patients with severe pulmonary conditions (acute respiratory distress syndrome (ARDS), n=5; status post lung transplantation, n=5; other, n=3) and declining respiratory function. CT scans were performed using a dual-source CT scanner at an expiratory xenon concentration of 30%. Both ventilation images (Xe-DECT) and standard CT images were reconstructed from a single CT scan. Findings were recorded for Xe-DECT and standard CT images separately. Ventilation defects on xenon images were matched to morphological findings on standard CT images and incremental diagnostic information of xenon ventilation images was recorded if present. Mean xenon consumption was 2.95 l per patient. No adverse events occurred under xenon inhalation. In the visual CT analysis, the Xe-DECT ventilation defects matched with pathologic changes in lung parenchyma seen in the standard CT images in all patients. Xe-DECT provided additional diagnostic findings in 4/13 patients. These included preserved ventilation despite early pneumonia (n=1), more confident discrimination between a large bulla and pneumothorax (n=1), detection of an airway-to-pneumothorax fistula (n=1) and exclusion of a suspected airway-to-mediastinum fistula (n=1). In all 4 patients, the additional findings had a substantial impact on patients' management. Xenon-enhanced DECT is safely feasible and can add relevant diagnostic information in mechanically ventilated intensive care patients with worsening respiratory function. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Isolated Main Pancreatic Duct Dilatation: CT Differentiation Between Benign and Malignant Causes.

    PubMed

    Kim, Se Woo; Kim, Se Hyung; Lee, Dong Ho; Lee, Sang Min; Kim, Yeon Soo; Jang, Jin Young; Han, Joon Koo

    2017-11-01

    The purpose of this study is to retrospectively evaluate the differential CT features of isolated benign and malignant main pancreatic duct (MPD) dilatation and to investigate whether the diagnostic performance of radiologists can be improved with knowledge of these differential CT features. Forty-one patients who had isolated MPD dilatation without any visible mass on CT from January 2000 to October 2016 were retrospectively enrolled in the study. Two radiologists reviewed CT images in consensus for the location, shape (smooth vs abrupt), length of transition, dilated pancreatic duct (PD) diameter, presence of duct penetrating sign, parenchymal atrophy, attenuation difference, associated pancreatitis, calcification, PD or common bile duct (CBD) enhancement, and perilesional cyst. The chi-square test, Fisher exact test, and t test were used to find the differential CT features of benign and malignant MPD dilatation. Two successive review sessions for differentiation between the two disease entities were then independently performed by three other reviewers with differing expertise, with the use of a 5-point confidence scale. The first session provided no information for differentiation; however, reviewers were aware of the results of univariate analyses in the second session. The diagnostic performance of the radiologists was evaluated using a pairwise comparison of ROC curves. A total of 19 benign and 22 malignant MPD dilatations were identified. In patients with benign MPD dilatation, transition areas were frequently located in the head (57.9% [11/19] vs 13.6% [3/22], p = 0.003) and showed significantly shorter (< 6.1 mm) (78.9% [15/19] vs 9.1% [2/22], p < 0.0001) and smooth transition (89.5% [17/19] vs 9.1% [2/22], p < 0.0001). Duct penetrating sign was exclusively observed in patients with benign MPD dilatation (73.7% [14/19] vs 0% [0/22], p < 0.0001). In contrast, malignant MPD dilatation frequently was accompanied by attenuation difference (63.6% [14/22] vs

  12. CT angiography versus conventional digital angiography in preoperative assessment for Chinese living kidney donors.

    PubMed

    Yap, Desmond Yat Hin; Chu, Ferdinand Siu Kay; Chu, Sai Man; Tam, Po Chor; Tam, Sidney; Chan, Tak Mao; Lai, Kar Neng; Tang, Sydney Chi Wai

    2010-01-01

    Computed tomography (CT) angiography is used for preoperative evaluation of living kidney donors, but its correlation with intraoperative findings during the transplant operation remains unknown. Between April 1997 and October 2008, 34 consecutive pairs of living kidney transplants were carried out. Conventional digital angiography was employed for the preoperative assessment in the first 19 pairs, and CT angiography in the subsequent 15 pairs. The radiological reports and operative findings during kidney harvest were carefully examined and compared. Among the 34 cases in our cohort, we found 9 early branching renal arteries (26.4%) and 6 double renal arteries (17%). Venous and ureteral anomalies were rare, with only 1 case (2.9%) of each. CT angiography offered excellent and equal accuracy (accuracy 100%) when compared with conventional digital angiography for renal arterial anatomy. CT angiography showed superior performance compared with conventional angiography in the domain of venous and collecting system anomalies (accuracy 100% vs. 94.7%, respectively). No contrast nephropathy or allergy was documented in our series. CT angiography showed excellent correlations with surgical findings in the Chinese population. It is associated with minimal risk of contrast nephropathy as well as lower cost and therefore should be adopted as the standard preoperative assessment of living kidney donors.

  13. Electromyography findings of the cricopharyngeus in association with ipsilateral pharyngeal and laryngeal muscles.

    PubMed

    Halum, Stacey L; Shemirani, Nima L; Merati, Albert L; Jaradeh, Safwan; Toohill, Robert J

    2006-04-01

    We reviewed a large series of cricopharyngeal (CP) muscle electromyography (EMG) results and compared them with the EMG results from the inferior constrictor (IC), thyroarytenoid, (TA), cricothyroid (CT), and posterior cricoarytenoid (PCA) muscles. We performed a retrospective review of all CP muscle EMG reports from studies performed between January 1996 and June 2003. All of the tested elements from the CP muscle EMG reports were recorded. The EMG results were recorded for the ipsilateral IC, TA, CT, and PCA muscles if they were simultaneously tested. Each muscle result was classified as normal, neurogenic inactive axonal injury (IAI), or neurogenic active axonal injury (AAI), and the muscle findings were compared. A patient chart review was performed to determine a clinical correlation. Fifty-nine patients underwent CP muscle EMG. Eighteen patients had bilateral EMG studies, making a total of 77 CP muscle studies. Nineteen sets of CP muscle results were normal, 43 demonstrated neurogenic IAI, and 15 demonstrated neurogenic AAI. The ipsilateral IC and CP muscles had the same innervation status in 27 of 28 studies (p < .0001). When the ipsilateral TA muscle was studied simultaneously with the CP muscle, 31 of 50 studies had the same innervation status (p = .005). The ipsilateral CT and CP muscles demonstrated the same innervation status in 40 of 50 studies (p < .0001). The correlations between the CP and IC muscle findings and between the CP and CT muscle findings were both stronger than the correlation between the CP and TA muscle findings (p < .0001 and p = .024, respectively). The chart review demonstrated the clinical findings to be consistent with the EMG results. The EMG studies demonstrated that CP muscle findings have the strongest correlation with IC muscle findings, followed by the CT and TA muscles. This outcome does not support theories indicating that the recurrent laryngeal nerve innervates the CP muscle in all cases.

  14. TU-H-CAMPUS-JeP2-02: Interobserver Variability of CT, PET-CT and MRI Based Primary Tumor Delineation for Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karki, K; Hugo, G; Saraiya, S

    Purpose: Target delineation in lung cancer radiotherapy has, in general, large variability. MRI has so far not been investigated in detail for lung cancer delineation variability. The purpose of this study is to investigate delineation variability for lung tumors using MRI and compare it to CT alone and PET-CT based delineations. Methods: Seven physicians delineated the primary tumor volumes of nine patients for the following scenarios: (1) CT only; (2) post-contrast T1-weighted MRI registered with diffusion-weighted MRI; and (3) PET-CT fusion images. To compute interobserver variability, the median surface was generated from all observers’ contours and used as the referencemore » surface. A single physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest-wall) on the median surface. Volume variation (normalized to PET-CT volume), minimum distance (MD), and bidirectional local distance (BLD) between individual observers’ contours and the reference contour were measured. Results: CT- and MRI-based normalized volumes were 1.61±0.76 (mean±SD) and 1.38±0.44, respectively, both significantly larger than PET-CT (p<0.05, paired t-test). The overall uncertainty (root mean square of SD values over all points) of both BLD and MD measures of the observers for the interfaces were not significantly different (p>0.05, two-samples t-test) for all imaging modalities except between tumor-mediastinum and tumor-atelectasis in PET-CT. The largest mean overall uncertainty was observed for tumor-atelectasis interface, the smallest for tumor-mediastinum and tumor-lung interfaces for all modalities. The whole tumor uncertainties for both BLD and MD were not significantly different between any two modalities (p>0.05, paired t-test). Overall uncertainties for the interfaces using BLD were similar to using MD. Conclusion: Large volume variations were observed between the three imaging modalities. Contouring variability appeared

  15. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT.

    PubMed

    Ciet, Pierluigi; Serra, Goffredo; Bertolo, Silvia; Spronk, Sandra; Ros, Mirco; Fraioli, Francesco; Quattrucci, Serena; Assael, M Baroukh; Catalano, Carlo; Pomerri, Fabio; Tiddens, Harm A W M; Morana, Giovanni

    2016-03-01

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100% (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). PROPELLER MRI does not match CT sensitivity to assess CF lung disease. PROPELLER MRI has lower sensitivity than CT to detect severe bronchiectasis. PROPELLER MRI has good to very good intra- and inter-observer variability. PROPELLER MRI can be used for short-term follow-up studies in CF.

  16. A dual tracer (68)Ga-DOTANOC PET/CT and (18)F-FDG PET/CT pilot study for detection of cardiac sarcoidosis.

    PubMed

    Gormsen, Lars C; Haraldsen, Ate; Kramer, Stine; Dias, Andre H; Kim, Won Yong; Borghammer, Per

    2016-12-01

    Cardiac sarcoidosis (CS) is a potentially fatal condition lacking a single test with acceptable diagnostic accuracy. (18)F-FDG PET/CT has emerged as a promising imaging modality, but is challenged by physiological myocardial glucose uptake. An alternative tracer, (68)Ga-DOTANOC, binds to somatostatin receptors on inflammatory cells in sarcoid granulomas. We therefore aimed to conduct a proof-of-concept study using (68)Ga-DOTANOC to diagnose CS. In addition, we compared diagnostic accuracy and inter-observer variability of (68)Ga-DOTANOC vs. (18)F-FDG PET/CT. Nineteen patients (seven female) with suspected CS were prospectively recruited and dual tracer scanned within 7 days. PET images were reviewed by four expert readers for signs of CS and compared to the reference standard (Japanese ministry of Health and Welfare CS criteria). CS was diagnosed in 3/19 patients. By consensus, 11/19 (18)F-FDG scans and 0/19 (68)Ga-DOTANOC scans were rated as inconclusive. The sensitivity of (18)F-FDG PET for diagnosing CS was 33 %, specificity was 88 %, PPV was 33 %, NPV was 88 %, and diagnostic accuracy was 79 %. For (68)Ga-DOTANOC, accuracy was 100 %. Inter-observer agreement was poor for (18)F-FDG PET (Fleiss' combined kappa 0.27, NS) and significantly better for (68)Ga-DOTANOC (Fleiss' combined kappa 0.46, p = 0.001). Despite prolonged pre-scan fasting, a large proportion of (18)F-FDG PET/CT images were rated as inconclusive, resulting in low agreement among reviewers and correspondingly poor diagnostic accuracy. By contrast, (68)Ga-DOTANOC PET/CT had excellent diagnostic accuracy with the caveat that inter-observer variability was still significant. Nevertheless, (68)Ga-DOTANOC PET/CT looks very promising as an alternative CS PET tracer. Current Controlled Trials NCT01729169 .

  17. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis

    PubMed Central

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a “routine” PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures. PMID:29348980

  18. Hybrid SPECT-CT and PET-CT imaging of differentiated thyroid carcinoma.

    PubMed

    Wong, K K; Zarzhevsky, N; Cahill, J M; Frey, K A; Avram, A M

    2009-10-01

    Hybrid imaging modalities such as radioiodine single photon emission CT with integrated CT ((131)I SPECT-CT) and 2-(fluorine-18)-fluoro-2-deoxy-D-glucose positron emission tomography with integrated CT (FDG PET-CT) allow the rapid and efficient fusion of functional and anatomic images, and provide diagnostic information that may influence management decisions in patients with differentiated thyroid carcinoma (DTC). Diagnostic localisation and therapy of these tumours are dependent upon their capacity to concentrate radioiodine ((131)I) via uptake through the sodium-iodide symporter and retention within the tumour. The prognosis for most patients with DTC is favourable, although controversy exists regarding the role of post-operative (131)I therapy in patients at low-risk for disease. Accurate identification of functional thyroid tissue (benign or malignant) using diagnostic (131)I planar scintigraphy complemented by SPECT-CT imaging enables the completion of post-operative staging and patient risk stratification prior to (131)I therapy administration. In patients with non-iodine-avid tumours (negative (131)I scan but elevated thyroglobulin indicative of persistent or recurrent disease), FDG PET-CT is used to identify tumours with enhanced glucose metabolism and to localise the source of thyroglobulin production. The CT component of this hybrid technology provides anatomic localisation of activity and allows CT-based attenuation correction of PET images. Images from 15 patients illustrate the applications of (131)I SPECT-CT and FDG PET-CT.

  19. Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images.

    PubMed

    Favazza, Christopher P; Ferrero, Andrea; Yu, Lifeng; Leng, Shuai; McMillan, Kyle L; McCollough, Cynthia H

    2017-07-01

    The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks-three different contrast levels and seven different diameters-was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.

  20. Integration of CT urography improves diagnostic confidence of 68Ga-PSMA-11 PET/CT in prostate cancer patients.

    PubMed

    Will, Leon; Giesel, Frederik L; Freitag, Martin T; Berger, Anne K; Mier, Walter; Kopka, Klaus; Koerber, Stefan A; Rathke, Hendrik; Kremer, Christophe; Kratochwil, Clemens; Kauczor, Hans-Ulrich; Haberkorn, Uwe; Weber, Tim F

    2017-12-20

    To prove the feasibility of integrating CT urography (CTU) into 68 Ga-PSMA-11 PET/CT and to analyze the impact of CTU on assigning focal tracer accumulation in the ureteric space to either ureteric excretion or metastatic disease concerning topographic attribution and diagnostic confidence. Ten prostate cancer patients who underwent 68 Ga-PSMA-11 PET/CT including CTU because of biochemical relapse or known metastatic disease were retrospectively analyzed. CTU consisted of an excretory phase 10 min after injection of 80 mL iodinated contrast material. Ureter opacification at CTU was evaluated using the following score: 0, 0% opacification; 1, < 50%; 2, 50-99%; 3, 100%. Topographic attribution and confidence of topographic attribution of focal tracer accumulation in the ureteric space were separately assessed for 68 Ga-PSMA-11 PET/CT without and with CTU. Diagnostic confidence was evaluated using the following score: 0, < 25% confidence; 1, 26-50%; 2, 51-75%; 3, 76-100%. At CTU, mean ureter opacification score was 2.6 ± 0.7. At 68 Ga-PSMA-11 PET/CT without CTU, mean confidence of topographic attribution of focal tracer accumulation was 2.5 ± 0.7 in total and 2.6 ± 0.7 for metastatic disease. At 68 Ga-PSMA-11 PET/CT with CTU, mean confidence of topographic attribution of focal areas of tracer accumulation was significantly higher with 2.9 ± 0.2 in total and 2.7 ± 0.9 for metastatic disease (p < 0.001). In 4 of 34 findings (12%) attribution to either ureteric excretion or metastatic disease was discrepant between 68 Ga-PSMA-11 PET/CT without and with CTU (n.s). Integration of CTU into 68 Ga-PSMA-11 PET/CT is feasible and increases diagnostic confidence of assigning focal areas of tracer accumulation in the ureteric space to either metastatic disease or ureteric excretion.

  1. Bosniak classification system: a prospective comparison of CT, contrast-enhanced US, and MR for categorizing complex renal cystic masses.

    PubMed

    Graumann, Ole; Osther, Susanne Sloth; Karstoft, Jens; Hørlyck, Arne; Osther, Palle Jörn Sloth

    2016-11-01

    Background The Bosniak classification was originally based on computed tomographic (CT) findings. Magnetic resonance (MR) and contrast-enhanced ultrasonography (CEUS) imaging may demonstrate findings that are not depicted at CT, and there may not always be a clear correlation between the findings at MR and CEUS imaging and those at CT. Purpose To compare diagnostic accuracy of MR, CEUS, and CT when categorizing complex renal cystic masses according to the Bosniak classification. Material and Methods From February 2011 to June 2012, 46 complex renal cysts were prospectively evaluated by three readers. Each mass was categorized according to the Bosniak classification and CT was chosen as gold standard. Kappa was calculated for diagnostic accuracy and data was compared with pathological results. Results CT images found 27 BII, six BIIF, seven BIII, and six BIV. Forty-three cysts could be characterized by CEUS, 79% were in agreement with CT (κ = 0.86). Five BII lesions were upgraded to BIIF and four lesions were categorized lower with CEUS. Forty-one lesions were examined with MR; 78% were in agreement with CT (κ = 0.91). Three BII lesions were upgraded to BIIF and six lesions were categorized one category lower. Pathologic correlation in six lesions revealed four malignant and two benign lesions. Conclusion CEUS and MR both up- and downgraded renal cysts compared to CT, and until these non-radiation modalities have been refined and adjusted, CT should remain the gold standard of the Bosniak classification.

  2. CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.

    PubMed

    Wang, Chunliang; Lundström, Claes

    2016-02-01

    The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.

  3. Italian Multicenter Study on Accuracy of 18F-FDG PET/CT in Assessing Bone Marrow Involvement in Pediatric Hodgkin Lymphoma.

    PubMed

    Cistaro, Angelina; Cassalia, Laura; Ferrara, Cinzia; Quartuccio, Natale; Evangelista, Laura; Bianchi, Maurizio; Fagioli, Franca; Bisi, Gianni; Baldari, Sergio; Zanella, Alessandro; Pillon, Marta; Zucchetta, Pietro; Burei, Marta; Sala, Alessandra; Guerra, Luca; Guglielmo, Priscilla; Burnelli, Roberta; Panareo, Stefano; Scalorbi, Federica; Rambaldi, Ilaria; Piccardo, Arnoldo; Garaventa, Alberto; Familiari, Demetrio; Fornito, Maria Concetta; Lopci, Egesta; Mascarin, Maurizio; Altini, Corinna; Ferrari, Cristina; Perillo, Teresa; Santoro, Nicola; Borsatti, Eugenio; Rubini, Giuseppe

    2018-06-01

    The present study investigated the utility of fluorine-18 ( 18 F) fluoro-2-deoxy-d-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in assessing bone marrow involvement (BMI) compared with bone marrow biopsy (BMB) in newly diagnosed pediatric Hodgkin lymphoma (HL). A total of 224 pediatric patients with HL underwent 18 F-FDG PET/CT at staging. BMB or follow-up imaging was used as the standard of reference for the evaluation of BMI. 18 F-FDG PET/CT was negative for BMI in 193 cases. Of the 193 patients, the findings for 16 were originally reported as doubtful and later interpreted as negative for BMI, with negative findings on follow-up imaging and BMB. At BMB, 1 of the 16 patients (6.25%) had BMI. Of the 193 patients, 192 (99.48%) had negative BMB findings. Thus, the 18 F-FDG PET/CT findings were truly negative for 192 patients and falsely negative for 1 patient for BMI. 18 F-FDG PET/CT showed high diagnostic performance in the evaluation of BMI in pediatric HL. Thus, BMB should be ideally reserved for patients presenting with doubtful 18 F-FDG PET/CT findings for BMI. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: a comparison of CT and CT-MRI based tissue segmentation on simulated temperature.

    PubMed

    Verhaart, René F; Fortunati, Valerio; Verduijn, Gerda M; van der Lugt, Aad; van Walsum, Theo; Veenland, Jifke F; Paulides, Margarethus M

    2014-12-01

    In current clinical practice, head and neck (H&N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors' study is to investigate the relevance of using MRI in addition to CT for patient modeling in H&N HTP. CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreous humor, and the optical nerve. For these tissues that are used for patient modeling in H&N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRIdb). To quantify the relevance of MRI based segmentation for H&N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (Tmax) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRIdb. In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1.40 mm). Patient models based on CT (Tmax: 38.0 °C) and CT and MRI

  5. The relevance of MRI for patient modeling in head and neck hyperthermia treatment planning: A comparison of CT and CT-MRI based tissue segmentation on simulated temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Verhaart, René F., E-mail: r.f.verhaart@erasmusmc.nl; Paulides, Margarethus M.; Fortunati, Valerio

    Purpose: In current clinical practice, head and neck (H and N) hyperthermia treatment planning (HTP) is solely based on computed tomography (CT) images. Magnetic resonance imaging (MRI) provides superior soft-tissue contrast over CT. The purpose of the authors’ study is to investigate the relevance of using MRI in addition to CT for patient modeling in H and N HTP. Methods: CT and MRI scans were acquired for 11 patients in an immobilization mask. Three observers manually segmented on CT, MRI T1 weighted (MRI-T1w), and MRI T2 weighted (MRI-T2w) images the following thermo-sensitive tissues: cerebrum, cerebellum, brainstem, myelum, sclera, lens, vitreousmore » humor, and the optical nerve. For these tissues that are used for patient modeling in H and N HTP, the interobserver variation of manual tissue segmentation in CT and MRI was quantified with the mean surface distance (MSD). Next, the authors compared the impact of CT and CT and MRI based patient models on the predicted temperatures. For each tissue, the modality was selected that led to the lowest observer variation and inserted this in the combined CT and MRI based patient model (CT and MRI), after a deformable image registration. In addition, a patient model with a detailed segmentation of brain tissues (including white matter, gray matter, and cerebrospinal fluid) was created (CT and MRI{sub db}). To quantify the relevance of MRI based segmentation for H and N HTP, the authors compared the predicted maximum temperatures in the segmented tissues (T{sub max}) and the corresponding specific absorption rate (SAR) of the patient models based on (1) CT, (2) CT and MRI, and (3) CT and MRI{sub db}. Results: In MRI, a similar or reduced interobserver variation was found compared to CT (maximum of median MSD in CT: 0.93 mm, MRI-T1w: 0.72 mm, MRI-T2w: 0.66 mm). Only for the optical nerve the interobserver variation is significantly lower in CT compared to MRI (median MSD in CT: 0.58 mm, MRI-T1w: 1.27 mm, MRI-T2w: 1

  6. Post-Ischemic Bowel Stricture: CT Features in Eight Cases

    PubMed Central

    Kim, Jin Sil; Hong, Seung-Mo; Park, Seong Ho; Lee, Jong Seok; Kim, Ah Young; Ha, Hyun Kwon

    2017-01-01

    Objective To investigate the characteristic radiologic features of post-ischemic stricture, which can then be implemented to differentiate that specific disease from other similar bowel diseases, with an emphasis on computed tomography (CT) features. Materials and Methods Eight patients with a diagnosis of ischemic bowel disease, who were also diagnosed with post-ischemic stricture on the basis of clinical or pathologic findings, were included. Detailed clinical data was collected from the available electronic medical records. Two radiologists retrospectively reviewed all CT images. Pathologic findings were also analyzed. Results The mean interval between the diagnosis of ischemic bowel disease and stricture formation was 57 days. The severity of ischemic bowel disease was variable. Most post-ischemic strictures developed in the ileum (n = 5), followed by the colon (n = 2) and then the jejunum (n = 1). All colonic strictures developed in the “watershed zone.” The pathologic features of post-ischemic stricture were deep ulceration, submucosal/subserosal fibrosis and chronic transmural inflammation. The mean length of the post-ischemic stricture was 7.4 cm. All patients in this study possessed one single stricture. On contrast-enhanced CT, most strictures possessed concentric wall thickening (87.5%), with moderate enhancement (87.5%), mucosal enhancement (50%), or higher enhancement in portal phase than arterial phase (66.7%). Conclusion Post-ischemic strictures develop in the ileum, jejunum and colon after an interval of several weeks. In the colonic segment, strictures mainly occur in the “watershed zone.” Typical CT findings include a single area of concentric wall thickening of medium length (mean, 7.4 cm), with moderate and higher enhancement in portal phase and vasa recta prominence. PMID:29089826

  7. Functional imaging in differentiating bronchial masses: an initial experience with a combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan.

    PubMed

    Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh

    2009-10-01

    To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.

  8. Micro X-ray CT imaging of pore-scale changes in unconsolidated sediment under confining pressure

    NASA Astrophysics Data System (ADS)

    Schindler, M.; Prasad, M.

    2017-12-01

    Micro X-ray computed tomography was used to image confining-pressure induced changes in a dry, unconsolidated quartz sand pack while simultaneously recording ultrasonic P-wave velocities. The experiments were performed under in-situ pressure of up to 4000 psi. The majority of digital rock physics studies rely on micro CT images obtained under ambient pressure and temperature conditions although effective rock properties strongly depend on in situ conditions. Goal of this work is to be able to obtain micro CT images of rock samples while pore and confining pressure is applied. Simultaneously we recorded ultrasonic P-wave velocities. The combination of imaging and velocity measurements provides insight in pore-scale changes in the rock and their influence on elastic properties. We visually observed a reduction in porosity by more than a third of the initial value as well as extensive grain damage, changes in pore and grain size distribution and an increase in contact number and contact radius with increasing confining pressure. An increase in measured ultrasonic P-wave velocities with increasing pressure was observed. We used porosity, contact number and contact radius obtained from micro CT images to model P-wave velocity with the contact-radius model by Bachrach et al. (1998). Our observations showed that the frame of unconsolidated sediments is significantly altered starting at pressures of only 1000 psi. This finding indicates that common assumptions in rock physics models (the solid frame remains unchanged) are violated for unconsolidated sediments. The effects on the solid frame should be taken into account when modeling the pressure dependence of elastic rock properties.

  9. Drought-induced embolism in stems of sunflower: A comparison of in vivo micro-CT observations and destructive hydraulic measurements.

    PubMed

    Savi, Tadeja; Miotto, Andrea; Petruzzellis, Francesco; Losso, Adriano; Pacilè, Serena; Tromba, Giuliana; Mayr, Stefan; Nardini, Andrea

    2017-11-01

    Vulnerability curves (VCs) are a useful tool to investigate the susceptibility of plants to drought-induced hydraulic failure, and several experimental techniques have been used for their measurement. The validity of the bench dehydration method coupled to hydraulic measurements, considered as a 'golden standard', has been recently questioned calling for its validation with non-destructive methods. We compared the VCs of a herbaceous crop plant (Helianthus annuus) obtained during whole-plant dehydration followed by i) hydraulic flow measurements in stem segments (classical destructive method) or by ii) in vivo micro-CT observations of stem xylem conduits in intact plants. The interpolated P 50 values (xylem water potential inducing 50% loss of hydraulic conductance) were -1.74 MPa and -0.87 MPa for the hydraulic and the micro-CT VC, respectively. Interpolated P 20 values were similar, while P 50 and P 80 were significantly different, as evidenced by non-overlapping 95% confidence intervals. Our results did not support the tension-cutting artefact, as no overestimation of vulnerability was observed when comparing the hydraulic VC to that obtained with in vivo imaging. After one scan, 25% of plants showed signs of x-ray induced damage, while three successive scans caused the formation of a circular brownish scar in all tested plants. Our results support the validity of hydraulic measurements of samples excised under tension provided standard sampling and handling protocols are followed, but also show that caution is needed when investigating vital plant processes with x-ray imaging. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Automatic segmentation and co-registration of gated CT angiography datasets: measuring abdominal aortic pulsatility

    NASA Astrophysics Data System (ADS)

    Wentz, Robert; Manduca, Armando; Fletcher, J. G.; Siddiki, Hassan; Shields, Raymond C.; Vrtiska, Terri; Spencer, Garrett; Primak, Andrew N.; Zhang, Jie; Nielson, Theresa; McCollough, Cynthia; Yu, Lifeng

    2007-03-01

    Purpose: To develop robust, novel segmentation and co-registration software to analyze temporally overlapping CT angiography datasets, with an aim to permit automated measurement of regional aortic pulsatility in patients with abdominal aortic aneurysms. Methods: We perform retrospective gated CT angiography in patients with abdominal aortic aneurysms. Multiple, temporally overlapping, time-resolved CT angiography datasets are reconstructed over the cardiac cycle, with aortic segmentation performed using a priori anatomic assumptions for the aorta and heart. Visual quality assessment is performed following automatic segmentation with manual editing. Following subsequent centerline generation, centerlines are cross-registered across phases, with internal validation of co-registration performed by examining registration at the regions of greatest diameter change (i.e. when the second derivative is maximal). Results: We have performed gated CT angiography in 60 patients. Automatic seed placement is successful in 79% of datasets, requiring either no editing (70%) or minimal editing (less than 1 minute; 12%). Causes of error include segmentation into adjacent, high-attenuating, nonvascular tissues; small segmentation errors associated with calcified plaque; and segmentation of non-renal, small paralumbar arteries. Internal validation of cross-registration demonstrates appropriate registration in our patient population. In general, we observed that aortic pulsatility can vary along the course of the abdominal aorta. Pulsation can also vary within an aneurysm as well as between aneurysms, but the clinical significance of these findings remain unknown. Conclusions: Visualization of large vessel pulsatility is possible using ECG-gated CT angiography, partial scan reconstruction, automatic segmentation, centerline generation, and coregistration of temporally resolved datasets.

  11. Coronary involvement in Churg-Strauss syndrome: a case report with CT findings.

    PubMed

    Doo, Kyung Won; Yong, Hwan Seok; Kang, Eun-Young

    2013-12-01

    We report a case of Churg-Strauss syndrome (CSS) associated with coronary artery involvement, as demonstrated on coronary CT angiography (CCTA), without specific cardiac symptoms. A 69-year-old male had an 8-year history of bronchial asthma and chronic sinusitis with hypereosinophilia (35 %), polyneuropathy, and a positive antineutrophil cytoplasmic antibody titer, so he was diagnosed with CSS. The patient had no specific cardiac symptoms, but CCTA showed vasculitis and a saccular aneurysm involving the proximal coronary arteries. The 3-year follow-up CCTA demonstrated an increase in the extent of soft-tissue wall thickening and infiltration involving the coronary arteries. Although vasculitis of the major coronary arteries is not a prominent feature of CSS, our case suggests that the coronary arteries may also be targeted in this syndrome.

  12. The relationship between computed tomography findings and the locations of perforated peptic ulcers: it may provide better information for gastrointestinal surgeons.

    PubMed

    Wang, Shang-Yu; Cheng, Chi-Tung; Liao, Chien-Hung; Fu, Chih-Yuan; Wong, Yon-Cheong; Chen, Huan-Wu; Ouyang, Chun-Hsiang; Kuo, I-Ming; Hsu, Yu-Pao; Yeh, Chun-Nan

    2016-10-01

    Computed tomography (CT) plays an important role in diagnosing gastrointestinal perforation. This study explored the relationship between CT findings and the locations of perforated peptic ulcers (PPUs), which may help further surgical planning. During a 34-month period, 175 patients had CT scans. We categorized those 175 patients into 2 groups: patients with and without a PPU at a difficult ulcer site for a laparoscopic approach. Both clinical data and the CT images were reviewed and analyzed. Based on the univariate analysis results, we conducted multivariate analyses of 3 factors: age, American Society of Anesthesiologists classification of 3 or more, and positive lesser sac image findings. The positive lesser sac findings in CT were the only independent factor that was correlated to the PPU site. Positive lesser sac CT findings may help to predict PPUs in sites where a laparoscopic approach might be difficult. Our study re-evaluates the additional value of CT scanning in diagnosing PPU, and the results may assist with surgical planning in clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. xCT (SLC7A11)-mediated metabolic reprogramming promotes non-small cell lung cancer progression.

    PubMed

    Ji, Xiangming; Qian, Jun; Rahman, S M Jamshedur; Siska, Peter J; Zou, Yong; Harris, Bradford K; Hoeksema, Megan D; Trenary, Irina A; Heidi, Chen; Eisenberg, Rosana; Rathmell, Jeffrey C; Young, Jamey D; Massion, Pierre P

    2018-05-23

    Many tumors increase uptake and dependence on glucose, cystine or glutamine. These basic observations on cancer cell metabolism have opened multiple new diagnostic and therapeutic avenues in cancer research. Recent studies demonstrated that smoking could induce the expression of xCT (SLC7A11) in oral cancer cells, suggesting that overexpression of xCT may support lung tumor progression. We hypothesized that overexpression of xCT occurs in lung cancer cells to satisfy the metabolic requirements for growth and survival. Our results demonstrated that 1) xCT was highly expressed at the cytoplasmic membrane in non-small cell lung cancer (NSCLC), 2) the expression of xCT was correlated with advanced stage and predicted a worse 5-year survival, 3) targeting xCT transport activity in xCT overexpressing NSCLC cells with sulfasalazine decreased cell proliferation and invasion in vitro and in vivo and 4) increased dependence on glutamine was observed in xCT overexpressed normal airway epithelial cells. These results suggested that xCT regulate metabolic requirements during lung cancer progression and be a potential therapeutic target in NSCLC.

  14. Low-voltage chest CT: another way to reduce the radiation dose in asbestos-exposed patients.

    PubMed

    Macía-Suárez, D; Sánchez-Rodríguez, E; Lopez-Calviño, B; Diego, C; Pombar, M

    2017-09-01

    To assess whether low voltage chest computed tomography (CT) can be used to successfully diagnose disease in patients with asbestos exposure. Fifty-six former employees of the shipbuilding industry, who were candidates to receive a standard-dose chest CT due to their occupational exposure to asbestos, underwent a routine CT. Immediately after this initial CT, they underwent a second acquisition using low-dose chest CT parameters, based on a low potential (80 kV) and limited tube current. The findings of the two CT protocols were compared based on typical diseases associated with asbestos exposure. The kappa coefficient for each parameter and for an overall rating (grouping them based on mediastinal, pleural, and pulmonary findings) were calculated in order to test for correlations between the two protocols. A good correlation between routine and low-dose CT was demonstrated for most parameters with a mean radiation dose reduction of up to 83% of the effective dose based on the dose-length product between protocols. Low-dose chest CT, based on a limited tube potential, is useful for patients with an asbestos exposure background. Low-dose chest CT can be successfully used to minimise the radiation dose received by patients, as this protocol produced an estimated mean effective dose similar to that of an abdominal or pelvis plain film. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. 3D SPECT/CT fusion using image data projection of bone SPECT onto 3D volume-rendered CT images: feasibility and clinical impact in the diagnosis of bone metastasis.

    PubMed

    Ogata, Yuji; Nakahara, Tadaki; Ode, Kenichi; Matsusaka, Yohji; Katagiri, Mari; Iwabuchi, Yu; Itoh, Kazunari; Ichimura, Akira; Jinzaki, Masahiro

    2017-05-01

    We developed a method of image data projection of bone SPECT into 3D volume-rendered CT images for 3D SPECT/CT fusion. The aims of our study were to evaluate its feasibility and clinical usefulness. Whole-body bone scintigraphy (WB) and SPECT/CT scans were performed in 318 cancer patients using a dedicated SPECT/CT systems. Volume data of bone SPECT and CT were fused to obtain 2D SPECT/CT images. To generate our 3D SPECT/CT images, colored voxel data of bone SPECT were projected onto the corresponding location of the volume-rendered CT data after a semi-automatic bone extraction. Then, the resultant 3D images were blended with conventional volume-rendered CT images, allowing to grasp the three-dimensional relationship between bone metabolism and anatomy. WB and SPECT (WB + SPECT), 2D SPECT/CT fusion, and 3D SPECT/CT fusion were evaluated by two independent reviewers in the diagnosis of bone metastasis. The inter-observer variability and diagnostic accuracy in these three image sets were investigated using a four-point diagnostic scale. Increased bone metabolism was found in 744 metastatic sites and 1002 benign changes. On a per-lesion basis, inter-observer agreements in the diagnosis of bone metastasis were 0.72 for WB + SPECT, 0.90 for 2D SPECT/CT, and 0.89 for 3D SPECT/CT. Receiver operating characteristic analyses for the diagnostic accuracy of bone metastasis showed that WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT had an area under the curve of 0.800, 0.983, and 0.983 for reader 1, 0.865, 0.992, and 0.993 for reader 2, respectively (WB + SPECT vs. 2D or 3D SPECT/CT, p < 0.001; 2D vs. 3D SPECT/CT, n.s.). The durations of interpretation of WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT images were 241 ± 75, 225 ± 73, and 182 ± 71 s for reader 1 and 207 ± 72, 190 ± 73, and 179 ± 73 s for reader 2, respectively. As a result, it took shorter time to read 3D SPECT/CT images than 2D SPECT/CT (p < 0.0001) or WB

  16. A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty

    PubMed Central

    2014-01-01

    Background and purpose It is difficult to evaluate glenoid component periprosthetic radiolucencies in total shoulder arthroplasties (TSAs) using plain radiographs. This study was performed to evaluate whether computed tomography (CT) using a specific patient position in the CT scanner provides a better method for assessing radiolucencies in TSA. Methods Following TSA, 11 patients were CT scanned in a lateral decubitus position with maximum forward flexion, which aligns the glenoid orientation with the axis of the CT scanner. Follow-up CT scanning is part of our routine patient care. Glenoid component periprosthetic lucency was assessed according to the Molé score and it was compared to routine plain radiographs by 5 observers. Results The protocol almost completely eliminated metal artifacts in the CT images and allowed accurate assessment of periprosthetic lucency of the glenoid fixation. Positioning of the patient within the CT scanner as described was possible for all 11 patients. A radiolucent line was identified in 54 of the 55 observed CT scans and osteolysis was identified in 25 observations. The average radiolucent line Molé score was 3.4 (SD 2.7) points with plain radiographs and 9.5 (SD 0.8) points with CT scans (p = 0.001). The mean intra-observer variance was lower in the CT scan group than in the plain radiograph group (p = 0.001). Interpretation The CT scan protocol we used is of clinical value in routine assessment of glenoid periprosthetic lucency after TSA. The technique improves the ability to detect and monitor radiolucent lines and, therefore, possibly implant loosening also. PMID:24286563

  17. Utility of MRI for cervical spine clearance in blunt trauma patients after a negative CT.

    PubMed

    Malhotra, Ajay; Durand, David; Wu, Xiao; Geng, Bertie; Abbed, Khalid; Nunez, Diego B; Sanelli, Pina

    2018-07-01

    To determine the utility of cervical spine MRI in blunt trauma evaluation for instability after a negative non-contrast cervical spine CT. A review of medical records identified all adult patients with blunt trauma who underwent CT cervical spine followed by MRI within 48 h over a 33-month period. Utility of subsequent MRI was assessed in terms of findings and impact on outcome. A total of 1,271 patients with blunt cervical spine trauma underwent both cervical spine CT and MRI within 48 h; 1,080 patients were included in the study analysis. Sixty-six percent of patients with a CT cervical spine study had a negative study. Of these, the subsequent cervical spine MRI had positive findings in 20.9%; 92.6% had stable ligamentous or osseous injuries, 6.0% had unstable injuries and 1.3% had potentially unstable injuries. For unstable injury, the NPV for CT was 98.5%. In all 712 patients undergoing both CT and MRI, only 1.5% had unstable injuries, and only 0.42% had significant change in management. MRI for blunt trauma evaluation remains not infrequent at our institution. MRI may have utility only in certain patients with persistent abnormal neurological examination. • MRI has limited utility after negative cervical CT in blunt trauma. • MRI is frequently positive for non-specific soft-tissue injury. • Unstable injury missed on CT is infrequent.

  18. Medical thoracoscopy vs CT scan-guided Abrams pleural needle biopsy for diagnosis of patients with pleural effusions: a randomized, controlled trial.

    PubMed

    Metintas, Muzaffer; Ak, Guntulu; Dundar, Emine; Yildirim, Huseyin; Ozkan, Ragip; Kurt, Emel; Erginel, Sinan; Alatas, Fusun; Metintas, Selma

    2010-06-01

    In cases of pleural effusion, tissue samples can be obtained through Abrams needle pleural biopsy (ANPB), thoracoscopy, or cutting-needle pleural biopsy under the guidance of CT scan (CT-CNPB) for histopathologic analysis. This study aimed to compare the diagnostic efficiency and reliability of ANPB under CT scan guidance (CT-ANPB) with that of medical thoracoscopy in patients with pleural effusion. Between January 2006 and January 2008, 124 patients with exudative pleural effusion that could not be diagnosed by cytologic analysis were included in the study. All patients were randomized after the CT scan was performed. Patients either underwent CT-ANPB or thoracoscopy. The two groups were compared in terms of diagnostic sensitivity and complications associated with the methods used. Of the 124 patients, malignant mesothelioma was diagnosed in 33, metastatic pleural disease in 47, benign pleural disease in 42, and two were of indeterminate origin. In the CT-ANPB group, the diagnostic sensitivity was 87.5%, as compared with 94.1% in the thoracoscopy group; the difference was not statistically significant (P = .252). No difference was identified between the sensitivities of the two methods based on the cause, the CT scan findings, and the degree of pleural thickening. Complication rates were low and acceptable. We recommend the use of CT-ANPB as the primary method of diagnosis in patients with pleural thickening or lesions observed by CT scan. In patients with only pleural fluid appearance on CT scan and in those who may have benign pleural pathologies other than TB, the primary method of diagnosis should be medical thoracoscopy. clinicaltrials.gov; Identifier: NCT00720954.

  19. Non-rigid registration of serial dedicated breast CT, longitudinal dedicated breast CT and PET/CT images using the diffeomorphic demons method.

    PubMed

    Santos, Jonathan; Chaudhari, Abhijit J; Joshi, Anand A; Ferrero, Andrea; Yang, Kai; Boone, John M; Badawi, Ramsey D

    2014-09-01

    Dedicated breast CT and PET/CT scanners provide detailed 3D anatomical and functional imaging data sets and are currently being investigated for applications in breast cancer management such as diagnosis, monitoring response to therapy and radiation therapy planning. Our objective was to evaluate the performance of the diffeomorphic demons (DD) non-rigid image registration method to spatially align 3D serial (pre- and post-contrast) dedicated breast computed tomography (CT), and longitudinally-acquired dedicated 3D breast CT and positron emission tomography (PET)/CT images. The algorithmic parameters of the DD method were optimized for the alignment of dedicated breast CT images using training data and fixed. The performance of the method for image alignment was quantitatively evaluated using three separate data sets; (1) serial breast CT pre- and post-contrast images of 20 women, (2) breast CT images of 20 women acquired before and after repositioning the subject on the scanner, and (3) dedicated breast PET/CT images of 7 women undergoing neo-adjuvant chemotherapy acquired pre-treatment and after 1 cycle of therapy. The DD registration method outperformed no registration (p < 0.001) and conventional affine registration (p ≤ 0.002) for serial and longitudinal breast CT and PET/CT image alignment. In spite of the large size of the imaging data, the computational cost of the DD method was found to be reasonable (3-5 min). Co-registration of dedicated breast CT and PET/CT images can be performed rapidly and reliably using the DD method. This is the first study evaluating the DD registration method for the alignment of dedicated breast CT and PET/CT images. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Neuroimaging findings in pediatric sports-related concussion.

    PubMed

    Ellis, Michael J; Leiter, Jeff; Hall, Thomas; McDonald, Patrick J; Sawyer, Scott; Silver, Norm; Bunge, Martin; Essig, Marco

    2015-09-01

    The goal in this review was to summarize the results of clinical neuroimaging studies performed in patients with sports-related concussion (SRC) who were referred to a multidisciplinar ypediatric concussion program. The authors conducted a retrospective review of medical records and neuroimaging findings for all patients referred to a multidisciplinary pediatric concussion program between September 2013 and July 2014. Inclusion criteria were as follows: 1) age ≤ 19 years; and 2) physician-diagnosed SRC. All patients underwent evaluation and follow-up by the same neurosurgeon. The 2 outcomes examined in this review were the frequency of neuroimaging studies performed in this population (including CT and MRI) and the findings of those studies. Clinical indications for neuroimaging and the impact of neuroimaging findings on clinical decision making were summarized where available. This investigation was approved by the local institutional ethics review board. A total of 151 patients (mean age 14 years, 59% female) were included this study. Overall, 36 patients (24%) underwent neuroimaging studies, the results of which were normal in 78% of cases. Sixteen percent of patients underwent CT imaging; results were normal in 79% of cases. Abnormal CT findings included the following: arachnoid cyst (1 patient), skull fracture (2 patients), suspected intracranial hemorrhage (1 patient), and suspected hemorrhage into an arachnoid cyst (1 patient). Eleven percent of patients underwent MRI; results were normal in 75% of cases. Abnormal MRI findings included the following: intraparenchymal hemorrhage and sylvian fissure arachnoid cyst (1 patient); nonhemorrhagic contusion (1 patient); demyelinating disease (1 patient); and posterior fossa arachnoid cyst, cerebellar volume loss, and nonspecific white matter changes (1 patient). Results of clinical neuroimaging studies are normal in the majority of pediatric patients with SRC. However, in selected cases neuroimaging can provide

  1. Postmortem CT versus forensic autopsy: frequent discrepancies of tracheobronchial content findings.

    PubMed

    Zech, Wolf-Dieter; Jackowski, Christian; Schwendener, Nicole; Brencicova, Eva; Schuster, Frederick; Lombardo, Paolo

    2016-01-01

    In their daily forensic casework, the authors experienced discrepancies of tracheobronchial content findings between postmortem computed tomography (PMCT) and autopsy to an extent previously unnoticed in the literature. The goal of this study was to evaluate such discrepancies in routine forensic cases. A total of 327 cases that underwent PMCT prior to routine forensic autopsy were retrospectively evaluated for tracheal and bronchial contents according to PMCT and autopsy findings. Hounsfield unit (HU) values of tracheobronchial contents, causes of death, and presence of pulmonary edema were assessed in mismatching and matching cases. Comparing contents in PMCT and autopsy in each of the separately evaluated compartments of the respiratory tract low positive predictive values were assessed (trachea, 38.2%; main bronchi, 40%; peripheral bronchi, 69.1%) indicating high discrepancy rates. The majority of tracheobronchial contents were viscous stomach contents in matching cases and low radiodensity materials (i.e., HU < 30) in mismatching cases. The majority of causes of death were cardiac related in the matching cases and skull/brain trauma in the mismatching cases. In mismatching cases, frequency of pulmonary edema was significantly higher than in matching cases. It can be concluded that discrepancies in tracheobronchial contents observed between PMCT and routine forensic autopsy occur in a considerable number of cases. Discrepancies may be explained by the runoff of contents via nose and mouth during external examination and the flow back of tracheal and main bronchial contents into the lungs caused by upright movement of the respiratory tract at autopsy.

  2. Abdominal CT scan

    MedlinePlus

    Computed tomography scan - abdomen; CT scan - abdomen; CT abdomen and pelvis ... An abdominal CT scan makes detailed pictures of the structures inside your belly very quickly. This test may be used to look ...

  3. Leveraging Terminologies for Retrieval of Radiology Reports with Critical Imaging Findings

    PubMed Central

    Warden, Graham I.; Lacson, Ronilda; Khorasani, Ramin

    2011-01-01

    Introduction: Communication of critical imaging findings is an important component of medical quality and safety. A fundamental challenge includes retrieval of radiology reports that contain these findings. This study describes the expressiveness and coverage of existing medical terminologies for critical imaging findings and evaluates radiology report retrieval using each terminology. Methods: Four terminologies were evaluated: National Cancer Institute Thesaurus (NCIT), Radiology Lexicon (RadLex), Systemized Nomenclature of Medicine (SNOMED-CT), and International Classification of Diseases (ICD-9-CM). Concepts in each terminology were identified for 10 critical imaging findings. Three findings were subsequently selected to evaluate document retrieval. Results: SNOMED-CT consistently demonstrated the highest number of overall terms (mean=22) for each of ten critical findings. However, retrieval rate and precision varied between terminologies for the three findings evaluated. Conclusion: No single terminology is optimal for retrieving radiology reports with critical findings. The expressiveness of a terminology does not consistently correlate with radiology report retrieval. PMID:22195212

  4. Simulation of the October-November 2003 solar proton event in the CMAM GCM: Comparison with observations

    NASA Technical Reports Server (NTRS)

    Semeniuk, K.; McConnell, J. C.; Jackman, C. H.

    2005-01-01

    The FTS instrument on SciSat-I observed a very large NO(x) anomaly in mid February of 2004 near 80 N in the lower mesosphere. It has been proposed that the most likely origin of the lower mesosphere anomaly in February is transport, from the lower thermosphere or upper mesosphere, of high levels of NO(x) associated with high levels of solar activity in 0ct.-Nov. 2003. There was no major solar flare activity during January and February to cause ionization in the mesosphere. Using a middle atmosphere GCM we investigate whether the NO(x) produced directly by the 0ct.-Nov. 2003 solar flares or indirectly via enhanced auroral ionization as a result of magnetospheric precipitation can explain the ACE observations. We find that the solar proton events associated with the solar explosions in 0ct.-Nov. 2003 produce insufficient amounts of NO(x), in the mesosphere and thermosphere (less than 2 ppm at 90 km) to give rise to the observed anomaly. However. there is evidence that intense aurorae caused by the 0ct.-Nov. 2003 solar storms produced thermospheric values of NO(x) reaching hundreds of ppm. The NO(x) created by the auroral particles appears to have lasted much longer than the immediate period of the 0ct.-Nov. 2003 solar storms. It appears that NO(x) rich air experienced confined polar night descent into the middle mesosphere during November and December, prior to the onset of the strong mesospheric vortex in January 2004.

  5. A challenging diagnosis of late-onset tumefactive multiple sclerosis associated to cervicodorsal syringomyelia: doubtful CT, MRI, and bioptic findings: Case report and literature review.

    PubMed

    Conforti, Renata; Capasso, Raffaella; Galasso, Rosario; Cirillo, Mario; Taglialatela, Gemma; Galasso, Luigi

    2016-09-01

    Tumefactive multiple sclerosis (MS) is an unusual variant of demyelinating disease characterized by lesions with pseudotumoral appearance on radiological imaging mimicking other space-occupying lesions, such as neoplasms, infections, and infarction. Especially when the patient's medical history is incompatible with MS, the differential diagnosis between these lesions constitutes a diagnostic challenge often requiring histological investigation. An older age at onset makes distinguishing tumefactive demyelinating lesion (TDL) from tumors even more challenging. We report a case of brain TDL as the initial manifestation of late-onset MS associated with cervico-dorsal syringomyelia. A 66-year-old Caucasian woman with a 15-day history headache was referred to our hospital because of the acute onset of paraphasia. She suffered from noncommunicating syringomyelia associated to basilar impression and she reported a 10-year history of burning dysesthesia of the left side of the chest extended to the internipple line level. Computed tomography (CT) and magnetic resonance imaging (MRI) examinations revealed a left frontal lesion with features suspicious for a tumor. Given the degree of overlap with other pathologic processes, CT and MRI findings failed to provide an unambiguous diagnosis; furthermore, because of the negative cerebrospinal fluid analysis for oligoclonal bands, the absence of other lesions, and the heightened suspicion of neoplasia, the clinicians opted to perform a stereotactic biopsy. Brain specimen analysis did not exclude the possibility of perilesional reactive gliosis and the patient, receiving anitiedemigen therapy, was monthly followed up. In the meanwhile, the second histological opinion of the brain specimen described the absence of pleomorphic glial cells indicating a tumor. These findings were interpreted as destructive inflammatory demyelinating disease and according to the evolution of MRI lesion burden, MS was diagnosed. TDL still remains a

  6. Timely Antecedent CT or MRI Can Help Predict Hemorrhage Site of Posttreatment Head and Neck Cancer, With Digital Subtraction Angiography Used as the Reference Standard.

    PubMed

    Ku, Yi-Kang; Wong, Yon-Cheong; Fu, Chen-Ju; Tseng, Hsiao-Jung; Wang, Li-Jen; Wang, Chao-Jan; Chin, Shy-Chyi

    2016-04-01

    We investigated the timing of CT and MRI performed before digital subtraction angiography (DSA) in the prediction of hemorrhage sites in patients with head and neck cancers who present with acute oral or neck bleeding after receiving treatment. A total of 123 DSA examinations that evaluated 123 oral or neck bleeding events in 85 patients were analyzed. The last CT or MRI examinations performed within a time frame of 0-337 days before transarterial embolization were reviewed retrospectively, with three findings (pseudoaneurysm, air-containing necrotic tissue, and residual tumor) used to predict hemorrhage sites. DSA findings of pseudoaneurysm or active contrast extravasation were used as a reference standard. The sensitivity of CT and MRI for correctly predicting hemorrhage sites was used to determine the optimal timing of CT or MRI examinations performed before DSA. A total of 8.9% of the DSA examinations (11/123) had equivocal findings but were followed by another bleeding event for which DSA findings were positive. CT or MRI was statistically significantly better at predicting hemorrhage sites in patients with bleeding events associated with nonhypopharyngeal cancers (p = 0.019) than in those with bleeding events associated with hypopharyngeal cancers. The sensitivity of CT or MRI in the prediction of hemorrhage sites was statistically significantly higher for the common carotid artery and the internal carotid artery when CT or MRI was performed less than 30 days before bleeding events occurred. Prediction of hemorrhagic sites was better with the use of CT angiography than with the use of enhanced CT or MRI, although it was not statistically significant. DSA findings can temporarily be equivocal. CT or MRI examinations performed within 30 days of bleeding events can predict the site of hemorrhage. If no CT or MRI findings from the past 30 days are available, we suggest performing emergent CT angiography for the sake of obtaining better arterial detail.

  7. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.

    PubMed

    Makeev, Andrey; Glick, Stephen J

    2017-12-01

    Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.

  8. T staging of gastric cancer: role of multi-detector row CT.

    PubMed

    Kumano, Seishi; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Iannaccone, Riccardo; Nakata, Saki; Onishi, Hiromitsu; Osuga, Keigo; Tomoda, Kaname; Catalano, Carlo; Nakamura, Hironobu

    2005-12-01

    To evaluate retrospectively the accuracy of multi-detector row computed tomography (CT) in the assessment of serosal invasion in patients with gastric cancer. The Ethics Committee does not require approval or informed consent for retrospective studies. Forty-one consecutive patients (24 men, 17 women; mean age, 68 years) with gastric cancer were included in this study. All patients were given 600 mL of tap water to drink and were positioned prone or supine on the scanning table. The detector row configuration included four detector rows, a section thickness of 1.25 mm, a pitch of 6, and a reconstruction interval of 0.63 mm. Transverse and multiplanar reconstruction images were simultaneously evaluated by two independent observers to assess the depth of tumor invasion in the gastric wall (ie, T stage). T staging at multi-detector row CT was compared with T staging at histologic evaluation (reference standard), which was performed by means of surgical or histologic examination of the resected specimen. We also calculated the sensitivity, specificity, and accuracy of multi-detector row CT for each observer in the assessment of serosal invasion. Analysis of interobserver agreement showed substantial or almost perfect agreement (nonweighted kappa value of 0.78 and weighted kappa value of 0.85). Correct assessment of gastric wall invasion was 80% and 85% for observers 1 and 2, respectively. The sensitivity, specificity, and accuracy of multi-detector row CT in the assessment of serosal invasion were 90%, 95%, and 93%, respectively, for observer 1 and 80%, 97%, and 93%, respectively, for observer 2. Overstaging occurred in six patients, and understaging occurred in five patients. All understaged tumors were scirrhous subtype gastric cancer. Multi-detector row CT scanning of patients with gastric cancer gave 93% accuracy in the assessment of serosal invasion in patients with gastric cancer. RSNA, 2005

  9. CT Angiography (CTA)

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z CT Angiography (CTA) Computed tomography angiography (CTA) uses an ... are the limitations of CT Angiography? What is CT Angiography? Angiography is a minimally invasive medical test ...

  10. Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Souza, Warren D.; Kwok, Young; Deyoung, Chad

    2005-12-15

    Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CTmore » scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging.« less

  11. Direct micro-CT observation confirms the induction of embolism upon xylem cutting under tension

    USDA-ARS?s Scientific Manuscript database

    We used two different Synchrotron-based micro-CT facilities (SLS: Swiss Light Source, Villigen, Switzerland, and ALS: Advanced Light Source, Berkeley, CA USA) to test the excision artifact described by Wheeler et al. (2013). Specifically, we examined the impact of cutting xylem under tension and und...

  12. Cervical tuberculous adenitis: CT manifestations.

    PubMed

    Reede, D L; Bergeron, R T

    1985-03-01

    Cervical tuberculous adenitis is being seen with increasing frequency in the United States; in the appropriate clinical setting it should be included in the differential diagnosis of an asymptomatic neck mass. Patients are typically young adults who are recent arrivals from Southeast Asia. A history of tuberculosis is not always elicited nor is the chest radiograph always abnormal. All of these patients have positive purified protein derivative tests unless they are anergic. The CT findings may lead to the diagnosis. Several CT patterns of nodal disease can be seen in tuberculous adenitis; some may mimic benign and neoplastic disease. The presence of a multiloculated or multichambered (conglomerate nodal) mass with central lucency and thick rims of enhancement and minimally effaced fascial planes is highly suggestive of tuberculous adenitis, especially if the patient has a strongly positive tuberculosis skin test.

  13. Observation of the effect of targeted therapy of 64-slice spiral CT combined with cryoablation for liver cancer

    PubMed Central

    Yan, Qiao-Huan; Xu, Dian-Guo; Shen, Yan-Feng; Yuan, Ding-Ling; Bao, Jun-Hui; Li, Hai-Bin; Lv, Ying-Gang

    2017-01-01

    AIM To observe the effect of targeted therapy with 64-slice spiral computed tomography (CT) combined with cryoablation for liver cancer. METHODS A total of 124 patients (142 tumors) were enrolled into this study. According to the use of dual-slice spiral CT or 64-slice spiral CT as a guide technology, patients were divided into two groups: dual-slice group (n = 56, 65 tumors) and 64-slice group (n = 8, 77 tumors). All patients were accepted and received targeted therapy by an argon-helium superconducting surgery system. The guided scan times of the two groups was recorded and compared. In the two groups, the lesion ice coverage in diameter of ≥ 3 cm and < 3 cm were recorded, and freezing effective rate was compared. Hepatic perfusion values [hepatic artery perfusion (HAP), portal vein perfusion (PVP), and the hepatic arterial perfusion index (HAPI)] of tumor tissues, adjacent tissues and normal liver tissues at preoperative and postoperative four weeks in the two groups were compared. Local tumor changes were recorded and efficiency was compared at four weeks post-operation. Adverse events were recorded and compared between the two groups, including fever, pain, frostbite, nausea, vomiting, pleural effusion and abdominal bleeding. RESULTS Guided scan times in the dual-slice group was longer than that in the 64-slice group (t = 11.445, P = 0.000). The freezing effective rate for tumors < 3 cm in diameter in the dual-slice group (81.58%) was lower than that in the 64-slice group (92.86%) (χ2 = 5.707, P = 0.017). The HAP and HAPI of tumor tissues were lower at four weeks post-treatment than at pre-treatment in both groups (all P < 0.05), and those in the 64-slice group were lower than that in the dual-slice group (all P < 0.05). HAP and PVP were lower and HAPI was higher in tumor adjacent tissues at post-treatment than at pre-treatment (all P < 0.05). Furthermore, the treatment effect and therapeutic efficacy in the dual-slice group were lower than the 64-slice

  14. Technology as an Occasion for Structuring: Evidence from Observations of CT Scanners and the Social Order of Radiology Departments.

    ERIC Educational Resources Information Center

    Barley, Stephen R.

    1986-01-01

    New technologies such as the CT scanner are challenging traditional role relations among radiology workers and may be altering the organizational and occupational structure of radiological work. This paper expands recent sociological thought by showing how identical CT scanners occasion similar structuring processes and created divergent forms of…

  15. Assessment of Bowel Wall Enhancement for the Diagnosis of Intestinal Ischemia in Patients with Small Bowel Obstruction: Value of Adding Unenhanced CT to Contrast-enhanced CT.

    PubMed

    Chuong, Anh Minh; Corno, Lucie; Beaussier, Hélène; Boulay-Coletta, Isabelle; Millet, Ingrid; Hodel, Jérôme; Taourel, Patrice; Chatellier, Gilles; Zins, Marc

    2016-07-01

    Purpose To determine whether adding unenhanced computed tomography (CT) to contrast material-enhanced CT improves the diagnostic performance of decreased bowel wall enhancement as a sign of ischemia complicating mechanical small bowel obstruction (SBO). Materials and Methods This retrospective study was approved by the institutional review board, which waived the requirement for informed consent. Two gastrointestinal radiologists independently performed retrospective assessments of 164 unenhanced and contrast-enhanced CT studies from 158 consecutive patients (mean age, 71.2 years) with mechanical SBO. The reference standard was the intraoperative and/or histologic diagnosis (in 80 cases) or results from clinical follow-up in patients who did not undergo surgery (84 cases). Decreased bowel wall enhancement was evaluated with contrast-enhanced images then and both unenhanced and contrast-enhanced images 1 month later. Diagnostic performance of decreased bowel wall enhancement and confidence in the diagnosis were compared between the two readings by using McNemar and Wilcoxon signed rank tests. Interobserver agreement was assessed by using κ statistics and compared with bootstrapping. Results Ischemia was diagnosed in 41 of 164 (25%) episodes of SBO. For both observers, adding unenhanced images improved decreased bowel wall enhancement sensitivity (observer 1: 46.3% [19 of 41] vs 65.8% [27 of 41], P = .02; observer 2: 56.1% [23 of 41] vs 63.4% [26 of 41], P = .45), Youden index (from 0.41 to 0.58 for observer 1 and from 0.42 to 0.61 for observer 2), and confidence score (P < .001 for both). Specificity significantly increased for observer 2 (84.5% [104 of 123] vs 94.3% [116 of 123], P = .002), and interobserver agreement significantly increased, from moderate (κ = 0.48) to excellent (κ = 0.89; P < .0001). Conclusion Adding unenhanced CT to contrast-enhanced CT improved the sensitivity, diagnostic confidence, and interobserver agreement of the diagnosis of ischemia

  16. Assessment of coronary artery calcium by chest CT compared with EKG-gated cardiac CT in the multicenter AIDS cohort study.

    PubMed

    Chandra, Divay; Gupta, Aman; Leader, Joseph K; Fitzpatrick, Meghan; Kingsley, Lawrence A; Kleerup, Eric; Haberlen, Sabina A; Budoff, Matthew J; Witt, Mallory; Post, Wendy S; Sciurba, Frank C; Morris, Alison

    2017-01-01

    Individuals with HIV are at increased risk for coronary artery disease (CAD). Early detection of subclinical CAD by assessment of coronary artery calcium (CAC) may help risk stratify and prevent CAD events in these individuals. However, the current standard to quantify CAC i.e. Agatston scoring requires EKG-gated cardiac CT imaging. To determine if the assessment of CAC using non-EKG-gated chest CT and the Weston scoring system is a useful surrogate for Agatston scores in HIV-infected and HIV-uninfected individuals. CAC was assessed by both the Weston and Agatston score in 108 men enrolled in the Multicenter AIDS Cohort Study. Participants were 55.2 (IQR 50.4; 59.9) years old and 62 (57.4%) were seropositive for HIV. Inter-observer agreement (rs = 0.94, κ = 90.0%, p<0.001, n = 21) and intra-observer agreement (rs = 0.95, κ = 95.2%, p<0.001, n = 97) for category of Weston score were excellent. Weston scores were associated with similar CAD risk factors as Agatston scores (age, race, HDL cholesterol level, all p<0.05) in our cohort. There was excellent correlation (rs = 0.92, p<0.001) and agreement (κw = 0.77, p<0.001) between Weston and Agatston scores. This study is the first to examine calcium scoring using chest CT in HIV-infected individuals and to independently validate the Weston score as a surrogate for the Agatston score. In clinical or research settings where EKG-gated cardiac CT is not feasible for the assessment of coronary calcium, Weston scoring by using chest CT should be considered.

  17. Assessment of coronary artery calcium by chest CT compared with EKG-gated cardiac CT in the multicenter AIDS cohort study

    PubMed Central

    Chandra, Divay; Gupta, Aman; Leader, Joseph K.; Fitzpatrick, Meghan; Kingsley, Lawrence A.; Kleerup, Eric; Haberlen, Sabina A.; Budoff, Matthew J.; Witt, Mallory; Post, Wendy S.; Sciurba, Frank C.; Morris, Alison

    2017-01-01

    Rationale Individuals with HIV are at increased risk for coronary artery disease (CAD). Early detection of subclinical CAD by assessment of coronary artery calcium (CAC) may help risk stratify and prevent CAD events in these individuals. However, the current standard to quantify CAC i.e. Agatston scoring requires EKG-gated cardiac CT imaging. Objective To determine if the assessment of CAC using non-EKG-gated chest CT and the Weston scoring system is a useful surrogate for Agatston scores in HIV-infected and HIV-uninfected individuals. Methods and measurements CAC was assessed by both the Weston and Agatston score in 108 men enrolled in the Multicenter AIDS Cohort Study. Results Participants were 55.2 (IQR 50.4; 59.9) years old and 62 (57.4%) were seropositive for HIV. Inter-observer agreement (rs = 0.94, κ = 90.0%, p<0.001, n = 21) and intra-observer agreement (rs = 0.95, κ = 95.2%, p<0.001, n = 97) for category of Weston score were excellent. Weston scores were associated with similar CAD risk factors as Agatston scores (age, race, HDL cholesterol level, all p<0.05) in our cohort. There was excellent correlation (rs = 0.92, p<0.001) and agreement (κw = 0.77, p<0.001) between Weston and Agatston scores. Conclusions This study is the first to examine calcium scoring using chest CT in HIV-infected individuals and to independently validate the Weston score as a surrogate for the Agatston score. In clinical or research settings where EKG-gated cardiac CT is not feasible for the assessment of coronary calcium, Weston scoring by using chest CT should be considered. PMID:28453572

  18. CT imaging of ovarian yolk sac tumor with emphasis on differential diagnosis

    PubMed Central

    Li, Yang-Kang; Zheng, Yu; Lin, Jian-Bang; Xu, Gui-Xiao; Cai, Ai-Qun; Zhou, Xiu-Guo; Zhang, Guo-Jun

    2015-01-01

    Ovarian yolk sac tumors (YSTs) are rare neoplasms. No radiological study has been done to compare the imaging findings between this type of tumor and other ovarian tumors. Here we analyzed the CT findings of 11 pathologically proven ovarian YSTs and compared their imaging findings with 18 other types of ovarian tumors in the same age range. Patient age, tumor size, tumor shape, ascites and metastasis of two groups did not differ significantly (P > 0.05). A mixed solid-cystic nature, intratumoral hemorrhage, marked enhancement and dilated intratumoral vessel of two groups differed significantly (P < 0.05). The area under the ROC curve of four significant CT features was 0.679, 0.707, 0.705, and 1.000, respectively. Multivariate logistic regression analysis identified two independent signs of YST: intratumoral hemorrhage and marked enhancement. Our results show that certain suggestive CT signs that may be valuable for improving the accuracy of imaging diagnosis of YST and may be helpful in distinguishing YST from other ovarian tumors. PMID:26074455

  19. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    PubMed Central

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  20. Canadian CT head rule and New Orleans Criteria in mild traumatic brain injury: comparison at a tertiary referral hospital in Japan.

    PubMed

    Mata-Mbemba, Daddy; Mugikura, Shunji; Nakagawa, Atsuhiro; Murata, Takaki; Kato, Yumiko; Tatewaki, Yasuko; Takase, Kei; Kushimoto, Shigeki; Tominaga, Teiji; Takahashi, Shoki

    2016-01-01

    We compared Canadian computed tomography (CT) head rule (CCHR) and New Orleans Criteria (NOC) in predicting important CT findings in patients with mild traumatic brain injury (TBI). We included 142 consecutive patients with mild TBI [Glasgow coma scale (GCS) 13-15] who showed at least one of the risk factors stated in the CCHR or the NOC. We introduced two scores: a Canadian from the CCHR and a New Orleans from the NOC. A patient's score represented a sum of the number of positive items. We examined the relationship between scores or items and the presence of important CT findings. Only the Canadian was significantly associated with important CT findings in multivariate analyses and showed higher area under the receiver operating characteristic curve (AUC) either in all 142 patients (GCS 13-15: P = 0.0130; AUC = 0.69) or in the 67 with a GCS = 15 (P = 0.0128, AUC = 0.73). Of items, ">60 years" or "≥65 years" included in either guideline was the strongest predictor of important CT finding, followed by "GCS < 15 after 2 h" included only in the CCHR. In a tertiary referral hospital in Japan, CCHR had higher performance than the NOC in predicting important CT findings.

  1. Pelvic CT scan

    MedlinePlus

    CAT scan - pelvis; Computed axial tomography scan - pelvis; Computed tomography scan - pelvis; CT scan - pelvis ... Risks of CT scans include: Being exposed to radiation Allergic reaction to contrast dye CT scans do expose you to more radiation ...

  2. Shoulder CT scan

    MedlinePlus

    CAT scan - shoulder; Computed axial tomography scan - shoulder; Computed tomography scan - shoulder; CT scan - shoulder ... Risks of CT scans include: Being exposed to radiation Allergic reaction to contrast dye Birth defect if done during pregnancy CT scans ...

  3. [The role of computed tomography after functional surgery on the paranasal sinuses. Normal findings and an assessment of the surgical failures].

    PubMed

    Scribano, E; Ascenti, G; Cascio, F; Bellinvia, A; Mazziotti, S; Lamberto, S

    1999-09-01

    Functional endoscopic sinus surgery has become the technique of choice to treat benign or inflammatory diseases of paranasal sinuses resistant to medical therapy. The goal of this type of surgery is to open the obstructed sinus ostia and restore normal aeration and mucociliary clearance. Messerklinger's is the most widely used technique. We investigated the role of CT after functional endoscopic sinus surgery and describe CT findings of postoperative anatomical changes together with frequent complications and surgical failures. Twenty-seven patients with relapsing symptoms were examined with CT of paranasal sinuses 8-32 weeks after functional endoscopic sinus surgery. In all cases both preoperative CT and surgical reports were available: CT and surgical results were compared. In 21/27 patients nasosinusal changes were demonstrated with CT. Recurrent disease secondary to inflammation and/or fibrosis was observed in 14 cases. Residual disease was seen in 5 patients. A major orbital complication was found in 1 patient with diplopia. One patient exhibited a large interruption of cribriform plate with CSF fistula. CT permitted an accurate assessment of extension and results of functional endoscopic sinus surgery. CT is indicated in the postoperative study of the patients who a) present symptoms of cerebral and ocular complications (early after functional endoscopic sinus surgery); and b) do not respond to medical treatments 8-32 weeks after unsuccessful functional endoscopic sinus surgery. In these patients CT can demonstrate recurrent and/or residual nasosinusal disease and bony defects unintentionally caused by the surgeon during the procedure.

  4. Computed Tomography (CT) - Spine

    MedlinePlus

    ... Resources Professions Site Index A-Z Computed Tomography (CT) - Spine Computed tomography (CT) of the spine is ... of CT Scanning of the Spine? What is CT Scanning of the Spine? Computed tomography, more commonly ...

  5. Body CT (CAT Scan)

    MedlinePlus

    ... Resources Professions Site Index A-Z Computed Tomography (CT) - Body Computed tomography (CT) of the body uses ... of CT Scanning of the Body? What is CT Scanning of the Body? Computed tomography, more commonly ...

  6. Acute computed tomography findings in patients with acute confusion of non-traumatic aetiology.

    PubMed

    West, W M; Ali, A; West, K P; Stultz, R

    2011-10-01

    A retrospective review was undertaken of all patients referred for computed tomography (CT) scans of the head for acute onset of confusion, not consequent on head trauma, during the period June 1, 2004 to May 31, 2007. Data were obtained by Microsoft Word search of the reports of the Radiology Department of the University Hospital of the West Indies, Kingston, Jamaica. Two hundred and twenty-one patients were reviewed: 103 men and 118 women. The mean age of the sample was 64 years; 168 patients (76%) were 50 years old or older. Computed tomography scans were reported normal in 170 (76.9%) patients; 45 patients (20.4%) had definite acute intracranial CT findings. Findings were equivocal in three patients (1.4%) and unavailable for three (1.4%); 23.2% and 15.6% of patients above and below the age of 50 years respectively showed acute abnormalities on CT The most common acute finding on CT scan was an ischaemic infarct (68%). Other abnormalities included intracerebral haemorrhage and metastases 6.2% each, toxoplasmosis and primary brain tumour 4.2% each and subdural haematoma and meningitis 2.1% each. The diagnoses of toxoplasmosis were made based on appearances typical of toxoplasmosis on CT scans in patients whose request stated that they were HIV positive. In the sample reviewed, most patients who presented with acute confusion were above the age of 50 years. Overall, 20.4% of patients from all age groups had acute abnormalities on CT with a relative higher proportion, 23.2% versus 15.6% of those over 50 years, having acute pathology. The most common abnormality was an ischaemic infarct. This finding is similar to that in developed countries and unlike that seen in other developing countries where infectious aetiologies predominate.

  7. Radionuclide bone scan SPECT-CT: lowering the dose of CT significantly reduces radiation dose without impacting CT image quality

    PubMed Central

    Gupta, Sandeep Kumar; Trethewey, Scott; Brooker, Bree; Rutherford, Natalie; Diffey, Jenny; Viswanathan, Suresh; Attia, John

    2017-01-01

    The CT component of SPECT-CT is required for attenuation correction and anatomical localization of the uptake on SPECT but there is no guideline about the optimal CT acquisition parameters. In our department, a standard CT acquisition protocol was changed in 2013 to give lower radiation dose to the patient. In this study, we retrospectively compared the effects on patient dose as well as the CT image quality with current versus older CT protocols. Ninety nine consecutive patients [n=51 Standard dose ‘old’ protocol (SDP); n=48 lower dose ‘new’ protocol (LDP)] with lumbar spine SPECT-CT for bone scan were examined. The main differences between the two protocols were that SDP used 130 kVp tube voltage and reference current-time product of 70 mAs whereas the LDP used 110 kVp and 40 mAs respectively. Various quantitative parameters from the CT images were obtained and the images were also rated blindly by two experienced nuclear medicine physicians for bony definition and noise. The mean calculated dose length product of the LDP group (121.5±39.6 mGy.cm) was significantly lower compared to the SDP group patients (266.9±96.9 mGy.cm; P<0.0001). This translated into a significant reduction in the mean effective dose to 1.8 mSv from 4.0 mSv. The physicians reported better CT image quality for the bony structures in LDP group although for soft tissue structures, the SDP group had better image quality. The optimized new CT acquisition protocol significantly reduced the radiation dose to the patient and in-fact improved CT image quality for the assessment of bony structures. PMID:28533938

  8. Enhanced yield of chromosome aberrations after CT examinations in paediatric patients.

    PubMed

    Stephan, G; Schneider, K; Panzer, W; Walsh, L; Oestreicher, U

    2007-05-01

    To determine whether computed tomography (CT) could enhance the chromosome aberration yields in paediatric patients. Blood samples were taken before and after CT scans from 10 children for whom the medical justifications for CT examinations were accidental injuries and not diseases as investigated in earlier studies. Chromosome analysis was carried out in lymphocytes by fluorescence plus Giemsa (FPG) staining exclusively in metaphases of the first cell cycle in vitro. The mean blood dose of the 10 children was about 12.9 mGy which was determined by a newly developed dose estimation. Based on more than 20,000 analyzed cells it was found that after CT examination the frequencies of dicentrics (dic) and excess acentric fragments (ace) in lymphocytes were significantly increased. By subdividing the children into two age groups, those with an age from 0.4 years to 9 years and from 10 - 15 years, it became obvious that the observed increase in chromosome aberrations was mainly contributed by the younger age group. In this group the frequency of dicentrics was significantly increased whereas in the older group the observed increase was not significant. Our results demonstrate that CT examinations enhance the dicentrics yields in peripheral lymphocytes of children aged up to 15 years. Since in particular significantly increased dicentric yields could be observed in children with an age from 0.4 - 9 years, it can be assumed that children younger than 10 years may be more radiation sensitive than older subjects.

  9. FDG-Avid Portal Vein Tumor Thrombosis from Hepatocellular Carcinoma in Contrast-Enhanced FDG PET/CT

    PubMed Central

    Nguyen, Xuan Canh; Nguyen, Dinh Song Huy; Ngo, Van Tan; Maurea, Simone

    2015-01-01

    Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%). PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001). FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001). PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6%) had no extrahepatic metastasis, 3 cases (33.3%) had metastasis of regional lymph nodes, and 1 case (11.1%) presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are findings of FDG

  10. Sinus CT scan

    MedlinePlus

    CAT scan - sinus; Computed axial tomography scan - sinus; Computed tomography scan - sinus; CT scan - sinus ... Risks for a CT scan includes: Being exposed to radiation Allergic reaction to contrast dye CT scans expose you to more radiation than regular ...

  11. Assembly of human C-terminal binding protein (CtBP) into tetramers.

    PubMed

    Bellesis, Andrew G; Jecrois, Anne M; Hayes, Janelle A; Schiffer, Celia A; Royer, William E

    2018-06-08

    C-terminal binding protein 1 (CtBP1) and CtBP2 are transcriptional coregulators that repress numerous cellular processes, such as apoptosis, by binding transcription factors and recruiting chromatin-remodeling enzymes to gene promoters. The NAD(H)-linked oligomerization of human CtBP is coupled to its co-transcriptional activity, which is implicated in cancer progression. However, the biologically relevant level of CtBP assembly has not been firmly established; nor has the stereochemical arrangement of the subunits above that of a dimer. Here, multi-angle light scattering (MALS) data established the NAD + - and NADH-dependent assembly of CtBP1 and CtBP2 into tetramers. An examination of subunit interactions within CtBP1 and CtBP2 crystal lattices revealed that both share a very similar tetrameric arrangement resulting from assembly of two dimeric pairs, with specific interactions probably being sensitive to NAD(H) binding. Creating a series of mutants of both CtBP1 and CtBP2, we tested the hypothesis that the crystallographically observed interdimer pairing stabilizes the solution tetramer. MALS data confirmed that these mutants disrupt both CtBP1 and CtBP2 tetramers, with the dimer generally remaining intact, providing the first stereochemical models for tetrameric assemblies of CtBP1 and CtBP2. The crystal structure of a subtle destabilizing mutant suggested that small structural perturbations of the hinge region linking the substrate- and NAD-binding domains are sufficient to weaken the CtBP1 tetramer. These results strongly suggest that the tetramer is important in CtBP function, and the series of CtBP mutants reported here can be used to investigate the physiological role of the tetramer. © 2018 Bellesis et al.

  12. Dose profile variation with voltage in head CT scans using radiochromic films

    NASA Astrophysics Data System (ADS)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  13. Journal club: Acute abdominal pain in elderly patients: effect of radiologist awareness of clinicobiologic information on CT accuracy.

    PubMed

    Millet, Ingrid; Alili, Chakib; Bouic-Pages, Emmanuelle; Curros-Doyon, Fernanda; Nagot, Nicolas; Taourel, Patrice

    2013-12-01

    The purpose of this study was to assess whether the availability of clinicobiologic findings would affect the diagnostic performance of CT of elderly emergency department patients with nontraumatic acute abdominal pain. The cases of 333 consecutively registered patients 75 years old or older presenting to the emergency department with acute abdominal pain and who underwent CT were retrospectively reviewed by two radiologists blinded or not to the patient's clinicobiologic results. Diagnostic accuracy was calculated according to the level of correctly classified cases in both the entire cohort and a surgical subgroup and was compared between readings performed with and without knowledge of the clinicobiologic findings. Agreement between each reading and the reference diagnosis and interobserver agreement were assessed with kappa statistics. In both the entire cohort (87.4% vs 85.3%, p = 0.07) and the surgical group (94% vs 91%, p = 0.15), there was no significant difference in CT accuracy between diagnoses made when the radiologist was aware and those made when the radiologist was not aware of the clinicobiologic findings. Agreement between the CT diagnosis and the final diagnosis was excellent whether or not the radiologist was aware of the clinicobiologic findings. In the care of elderly patients, CT is accurate for diagnosing the cause of acute abdominal pain, particularly when it is of surgical origin, regardless of the availability of clinical and biologic findings. Thus CT interpretation should not be delayed until complete clinicobiologic data are available, and the images should be quickly transmitted to the emergency physician so that appropriate therapy can be begun.

  14. Development of proton CT imaging system using plastic scintillator and CCD camera

    NASA Astrophysics Data System (ADS)

    Tanaka, Sodai; Nishio, Teiji; Matsushita, Keiichiro; Tsuneda, Masato; Kabuki, Shigeto; Uesaka, Mitsuru

    2016-06-01

    A proton computed tomography (pCT) imaging system was constructed for evaluation of the error of an x-ray CT (xCT)-to-WEL (water-equivalent length) conversion in treatment planning for proton therapy. In this system, the scintillation light integrated along the beam direction is obtained by photography using the CCD camera, which enables fast and easy data acquisition. The light intensity is converted to the range of the proton beam using a light-to-range conversion table made beforehand, and a pCT image is reconstructed. An experiment for demonstration of the pCT system was performed using a 70 MeV proton beam provided by the AVF930 cyclotron at the National Institute of Radiological Sciences. Three-dimensional pCT images were reconstructed from the experimental data. A thin structure of approximately 1 mm was clearly observed, with spatial resolution of pCT images at the same level as that of xCT images. The pCT images of various substances were reconstructed to evaluate the pixel value of pCT images. The image quality was investigated with regard to deterioration including multiple Coulomb scattering.

  15. Clinical findings and results of diagnostic imaging in 82 dogs with gastrointestinal ulceration.

    PubMed

    Fitzgerald, E; Barfield, D; Lee, K C L; Lamb, C R

    2017-04-01

    To describe clinical and imaging findings in dogs with confirmed gastrointestinal ulceration, to compare findings in dogs with perforated and non-perforated ulcers and to estimate the sensitivities of radiography, ultrasonography and computed tomography (CT) for gastrointestinal ulceration and perforation. Retrospective review of medical records of 82 dogs that had a macroscopic ulcer in the gastric or intestinal mucosa diagnosed directly at endoscopy, surgery or necropsy and had survey radiography, ultrasonography or a CT scan of the abdomen during the same period of hospitalisation. The most frequent clinical signs were vomiting in 88% dogs, haematemesis in 32%, melaena in 31% and weight loss in 7%. The most frequent imaging findings in dogs with non-perforated ulcers were gastrointestinal mural lesion in 56%, mucosal defect compatible with an ulcer in 44% and peritoneal fluid in 21%. In dogs with perforated ulcers the most frequent imaging findings were peritoneal fluid in 83%, gastrointestinal mural lesion in 48%, peritoneal gas in 31% and mucosal defect compatible with an ulcer in 29%. Sensitivities of radiography, ultrasonography and CT were 30, 65 and 67% in dogs with non-perforated ulcers and 79, 86 and 93% in dogs with perforated ulcers, respectively. In dogs with non-perforated ulcers, survey radiography was usually negative whereas ultrasonography and CT frequently enabled detection of the site of the ulcer; in dogs with perforated ulcers, radiography was frequently positive for peritoneal gas and CT was a sensitive modality for both the ulcer and signs of perforation. © 2017 British Small Animal Veterinary Association.

  16. CT Enterography

    MedlinePlus

    ... equipped to deal with them. Advancements in CT technology now allow CT enterography to be performed with even lower radiation doses. Because children are more sensitive to radiation, they should have ...

  17. Chymopapain chemonucleolysis: CT changes after treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gentry, L.R.; Turski, P.A.; Strother, C.M.

    1985-08-01

    Chymopapain chemonucleolysis is now used extensively in this country to treat lumbar disk herniation. Despite increasing experience in patient selection, there continue to be patients who do not respond to treatment and require diagnostic reevaluation. Interpretation of postchemonucleolysis computed tomographic (CT) scans in these patients requires a knowledge of the CT changes that normally occur after treatment with chemonucleolysis. To define these temporal changes, a prospective CT evaluation was performed of 29 treated interspaces in 26 patients who returned for routine postchemonucleolysis follow-up. Despite a successful clinical response in 17 of 21 patients, changes in the size, location, shape, homogeneity,more » and density of the disk herniation were uncommon at the 6 week follow-up. In 24 treated interspaces, the most common changes at 6 week CT follow-up were the development of vacuum phenomenon in three (12.5%) and a slight decrease in the size of two (8.3%) disk herniations. A successful response was noted in 17 of 21 patients scanned at 6 month follow-up, with five (22.7%) of 22 injected interspaces exhibiting vacuum phenomenon and 13 (59.1%) interspaces showing an observable decrease in the size of the disk herniation.« less

  18. Efficacy and safety of CT-P13 (biosimilar infliximab) in patients with rheumatoid arthritis: comparison between switching from reference infliximab to CT-P13 and continuing CT-P13 in the PLANETRA extension study

    PubMed Central

    Yoo, Dae Hyun; Prodanovic, Nenad; Jaworski, Janusz; Miranda, Pedro; Ramiterre, Edgar; Lanzon, Allan; Baranauskaite, Asta; Wiland, Piotr; Abud-Mendoza, Carlos; Oparanov, Boycho; Smiyan, Svitlana; Kim, HoUng; Lee, Sang Joon; Kim, SuYeon; Park, Won

    2017-01-01

    Objectives To assess the efficacy and safety of switching from the infliximab reference product (RP; Remicade) to its biosimilar CT-P13 (Remsima, Inflectra) or continuing CT-P13 in patients with rheumatoid arthritis (RA) for an additional six infusions. Methods This open-label extension study recruited patients with RA who had completed the 54-week, randomised, parallel-group study comparing CT-P13 with RP (PLANETRA; NCT01217086). CT-P13 (3 mg/kg) was administered intravenously every 8 weeks from weeks 62 to 102. All patients received concomitant methotrexate. Endpoints included American College of Rheumatology 20% (ACR20) response, ACR50, ACR70, immunogenicity and safety. Data were analysed for patients who received CT-P13 for 102 weeks (maintenance group) and for those who received RP for 54 weeks and then switched to CT-P13 (switch group). Results Overall, 302 of 455 patients who completed the PLANETRA study enrolled into the extension. Of these, 158 had received CT-P13 (maintenance group) and 144 RP (switch group). Response rates at week 102 for maintenance versus switch groups, respectively, were 71.7% vs 71.8% for ACR20, 48.0% vs 51.4% for ACR50 and 24.3% vs 26.1% for ACR70. The proportion of patients with antidrug antibodies was comparable between groups (week 102: 40.3% vs 44.8%, respectively). Treatment-emergent adverse events occurred in similar proportions of patients in the two groups during the extension study (53.5% and 53.8%, respectively). Conclusions Comparable efficacy and tolerability were observed in patients who switched from RP to its biosimilar CT-P13 for an additional year and in those who had long-term CT-P13 treatment for 2 years. Trial registration number NCT01571219; Results. PMID:27130908

  19. Experimental Actinobacillus pleuropneumoniae challenge in swine: Comparison of computed tomographic and radiographic findings during disease

    PubMed Central

    2012-01-01

    Background In pigs, diseases of the respiratory tract like pleuropneumonia due to Actinobacillus pleuropneumoniae (App) infection have led to high economic losses for decades. Further research on disease pathogenesis, pathogen-host-interactions and new prophylactic and therapeutic approaches are needed. In most studies, a large number of experimental animals are required to assess lung alterations at different stages of the disease. In order to reduce the required number of animals but nevertheless gather information on the nature and extent of lung alterations in living pigs, a computed tomographic scoring system for quantifying gross pathological findings was developed. In this study, five healthy pigs served as control animals while 24 pigs were infected with App, the causative agent of pleuropneumonia in pigs, in an established model for respiratory tract disease. Results Computed tomographic (CT) findings during the course of App challenge were verified by radiological imaging, clinical, serological, gross pathology and histological examinations. Findings from clinical examinations and both CT and radiological imaging, were recorded on day 7 and day 21 after challenge. Clinical signs after experimental App challenge were indicative of acute to chronic disease. Lung CT findings of infected pigs comprised ground-glass opacities and consolidation. On day 7 and 21 the clinical scores significantly correlated with the scores of both imaging techniques. At day 21, significant correlations were found between clinical scores, CT scores and lung lesion scores. In 19 out of 22 challenged pigs the determined disease grades (not affected, slightly affected, moderately affected, severely affected) from CT and gross pathological examination were in accordance. Disease classification by radiography and gross pathology agreed in 11 out of 24 pigs. Conclusions High-resolution, high-contrast CT examination with no overlapping of organs is superior to radiography in the

  20. Early clinical applications for imaging at microscopic detail: microfocus computed tomography (micro-CT).

    PubMed

    Hutchinson, J Ciaran; Shelmerdine, Susan C; Simcock, Ian C; Sebire, Neil J; Arthurs, Owen J

    2017-07-01

    Microfocus CT (micro-CT) has traditionally been used in industry and preclinical studies, although it may find new applicability in the routine clinical setting. It can provide high-resolution three-dimensional digital imaging data sets to the same level of detail as microscopic examination without the need for tissue dissection. Micro-CT is already enabling non-invasive detailed internal assessment of various tissue specimens, particularly in breast imaging and early gestational fetal autopsy, not previously possible from more conventional modalities such as MRI or CT. In this review, we discuss the technical aspects behind micro-CT image acquisition, how early work with small animal studies have informed our knowledge of human disease and the imaging performed so far on human tissue specimens. We conclude with potential future clinical applications of this novel and emerging technique.

  1. CT arthrographic patterns in recurrent glenohumeral instability.

    PubMed

    Singson, R D; Feldman, F; Bigliani, L

    1987-10-01

    CT double-contrast arthrograms were performed on 54 shoulders in 53 patients with recurrent dislocation or subluxation to detect responsible underlying bony or soft-tissue abnormalities. Lesions of the anterior labrum in 52 (96%) of 54 cases and of the capsuloligamentous complex in 42 (78%) of 54 cases were the two most common abnormalities. There was no difference in the degree or number of labral lesions between subluxations and dislocations. However, more severe capsular lesions, subscapularis tendon tears, and widened subscapularis bursae were consistently found among patients with dislocations. Subsequent clinical, arthroscopic, and surgical findings showed that the use of CT double-contrast arthrograms resulted in improved definition of the multiple lesions associated with glenohumeral dysfunction.

  2. Micro-CT Based Experimental Liver Imaging Using a Nanoparticulate Contrast Agent: A Longitudinal Study in Mice

    PubMed Central

    Boll, Hanne; Nittka, Stefanie; Doyon, Fabian; Neumaier, Michael; Marx, Alexander; Kramer, Martin; Groden, Christoph; Brockmann, Marc A.

    2011-01-01

    Background Micro-CT imaging of liver disease in mice relies on high soft tissue contrast to detect small lesions like liver metastases. Purpose of this study was to characterize the localization and time course of contrast enhancement of a nanoparticular alkaline earth metal-based contrast agent (VISCOVER ExiTron nano) developed for small animal liver CT imaging. Methodology ExiTron nano 6000 and ExiTron nano 12000, formulated for liver/spleen imaging and angiography, respectively, were intravenously injected in C57BL/6J-mice. The distribution and time course of contrast enhancement were analysed by repeated micro-CT up to 6 months. Finally, mice developing liver metastases after intrasplenic injection of colon carcinoma cells underwent longitudinal micro-CT imaging after a single injection of ExiTron nano. Principal Findings After a single injection of ExiTron nano the contrast of liver and spleen peaked after 4–8 hours, lasted up to several months and was tolerated well by all mice. In addition, strong contrast enhancement of abdominal and mediastinal lymph nodes and the adrenal glands was observed. Within the first two hours after injection, particularly ExiTron nano 12000 provided pronounced contrast for imaging of vascular structures. ExiTron nano facilitated detection of liver metastases and provided sufficient contrast for longitudinal observation of tumor development over weeks. Conclusions The nanoparticulate contrast agents ExiTron nano 6000 and 12000 provide strong contrast of the liver, spleen, lymph nodes and adrenal glands up to weeks, hereby allowing longitudinal monitoring of pathological processes of these organs in small animals, with ExiTron nano 12000 being particularly optimized for angiography due to its very high initial vessel contrast. PMID:21984939

  3. 68Ga-PSMA-11 PET/CT in Newly Diagnosed Carcinoma of the Prostate: Correlation of Intraprostatic PSMA Uptake with Several Clinical Parameters.

    PubMed

    Koerber, Stefan A; Utzinger, Maximilian T; Kratochwil, Clemens; Kesch, Claudia; Haefner, Matthias F; Katayama, Sonja; Mier, Walter; Iagaru, Andrei H; Herfarth, Klaus; Haberkorn, Uwe; Debus, Juergen; Giesel, Frederik L

    2017-12-01

    68 Ga-prostate-specific membrane antigen (PSMA) PET/CT is a promising diagnostic tool for patients with prostate cancer. Our study evaluates SUVs in benign prostate tissue and malignant, intraprostatic tumor lesions and correlates results with several clinical parameters. Methods: One hundred four men with newly diagnosed prostate carcinoma and no previous therapy were included in this study. SUV max was measured and correlated with biopsy findings and MRI. Afterward, data were compared with current prostate-specific antigen (PSA) values, Gleason score (GS), and d'Amico risk classification. Results: In this investigation a mean SUV max of 1.88 ± 0.44 in healthy prostate tissue compared with 10.77 ± 8.45 in malignant prostate lesions ( P < 0.001) was observed. Patients with higher PSA, higher GS, and higher d'Amico risk score had statistically significant higher PSMA uptake on PET/CT ( P < 0.001 each). Conclusion: PSMA PET/CT is well suited for detecting the intraprostatic malignant lesion in patients with newly diagnosed prostate cancer. Our findings indicate a significant correlation of PSMA uptake with PSA, GS, and risk classification according to the d'Amico scale. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  4. Image Reconstruction for Hybrid True-Color Micro-CT

    PubMed Central

    Xu, Qiong; Yu, Hengyong; Bennett, James; He, Peng; Zainon, Rafidah; Doesburg, Robert; Opie, Alex; Walsh, Mike; Shen, Haiou; Butler, Anthony; Butler, Phillip; Mou, Xuanqin; Wang, Ge

    2013-01-01

    X-ray micro-CT is an important imaging tool for biomedical researchers. Our group has recently proposed a hybrid “true-color” micro-CT system to improve contrast resolution with lower system cost and radiation dose. The system incorporates an energy-resolved photon-counting true-color detector into a conventional micro-CT configuration, and can be used for material decomposition. In this paper, we demonstrate an interior color-CT image reconstruction algorithm developed for this hybrid true-color micro-CT system. A compressive sensing-based statistical interior tomography method is employed to reconstruct each channel in the local spectral imaging chain, where the reconstructed global gray-scale image from the conventional imaging chain served as the initial guess. Principal component analysis was used to map the spectral reconstructions into the color space. The proposed algorithm was evaluated by numerical simulations, physical phantom experiments, and animal studies. The results confirm the merits of the proposed algorithm, and demonstrate the feasibility of the hybrid true-color micro-CT system. Additionally, a “color diffusion” phenomenon was observed whereby high-quality true-color images are produced not only inside the region of interest, but also in neighboring regions. It appears harnessing that this phenomenon could potentially reduce the color detector size for a given ROI, further reducing system cost and radiation dose. PMID:22481806

  5. A phantom-based JAFROC observer study of two CT reconstruction methods: the search for optimisation of lesion detection and effective dose

    NASA Astrophysics Data System (ADS)

    Thompson, John D.; Chakraborty, Dev P.; Szczepura, Katy; Vamvakas, Ioannis; Tootell, Andrew; Manning, David J.; Hogg, Peter

    2015-03-01

    Purpose: To investigate the dose saving potential of iterative reconstruction (IR) in a computed tomography (CT) examination of the thorax. Materials and Methods: An anthropomorphic chest phantom containing various configurations of simulated lesions (5, 8, 10 and 12mm; +100, -630 and -800 Hounsfield Units, HU) was imaged on a modern CT system over a tube current range (20, 40, 60 and 80mA). Images were reconstructed with (IR) and filtered back projection (FBP). An ATOM 701D (CIRS, Norfolk, VA) dosimetry phantom was used to measure organ dose. Effective dose was calculated. Eleven observers (15.11+/-8.75 years of experience) completed a free response study, localizing lesions in 544 single CT image slices. A modified jackknife alternative free-response receiver operating characteristic (JAFROC) analysis was completed to look for a significant effect of two factors: reconstruction method and tube current. Alpha was set at 0.05 to control the Type I error in this study. Results: For modified JAFROC analysis of reconstruction method there was no statistically significant difference in lesion detection performance between FBP and IR when figures-of-merit were averaged over tube current (F(1,10)=0.08, p = 0.789). For tube current analysis, significant differences were revealed between multiple pairs of tube current settings (F(3,10) = 16.96, p<0.001) when averaged over image reconstruction method. Conclusion: The free-response study suggests that lesion detection can be optimized at 40mA in this phantom model, a measured effective dose of 0.97mSv. In high-contrast regions the diagnostic value of IR, compared to FBP, is less clear.

  6. Small bowel adenocarcinoma in Crohn disease: CT-enterography features with pathological correlation.

    PubMed

    Soyer, Philippe; Hristova, Lora; Boudghène, Frank; Hoeffel, Christine; Dray, Xavier; Laurent, Valérie; Fishman, Elliot K; Boudiaf, Mourad

    2012-06-01

    The aim of this study was to analyze the clinical, pathological, and CT-enterography findings of small bowel adenocarcinomas in Crohn disease patients. Clinical, histopathological, and imaging findings were retrospectively evaluated in seven Crohn disease patients with small bowel adenocarcinoma. CT-enterography examinations were reviewed for morphologic features and location of tumor, presence of stratification, luminal stenosis, proximal dilatation, adjacent lymph nodes, and correlated with findings at histological examination. The tumor was located in the terminal (n = 6) or distal (n = 1) ileum. On CT-enterography, the tumor was visible in five patients, whereas two patients had no visible tumor. Four different patterns were individualized including small bowel mass (n = 2), long stenosis with heterogeneous submucosal layer (n = 2), short and severe stenosis with proximal small bowel dilatation (n = 2), and sacculated small bowel loop with irregular and asymmetric circumferential thickening (n = 1). Stratification, fat stranding, and comb sign were present in two, two, and one patients, respectively. Identification of a mass being clearly visible suggests strongly the presence of small bowel adenocarcinoma in Crohn disease patients but adenocarcinoma may be completely indistinguishable from benign fibrotic or acute inflammatory stricture. Knowledge of these findings is critical to help suggest the diagnosis of this rare but severe complication of Crohn disease.

  7. 18F-Fluorocholine PET/CT in the assessment of primary hyperparathyroidism compared with 99mTc-MIBI or 99mTc-tetrofosmin SPECT/CT: a prospective dual-centre study in 100 patients.

    PubMed

    Beheshti, Mohsen; Hehenwarter, Lukas; Paymani, Zeinab; Rendl, Gundula; Imamovic, Larisa; Rettenbacher, Rupert; Tsybrovskyy, Oleksiy; Langsteger, Werner; Pirich, Christian

    2018-03-08

    In this prospective study we compared the accuracy of 18 F-fluorocholine PET/CT with that of 99m Tc-MIBI or 99m Tc-tetrofosmin SPECT/CT in the preoperative detection of parathyroid adenoma in patients with primary hyperparathyroidism. We also assessed the value of semiquantitative parameters in differentiating between parathyroid hyperplasia and adenoma. Both 18 F-fluorocholine PET/CT and 99m Tc-MIBI/tetrofosmin SPECT/CT were performed in 100 consecutive patients with biochemical evidence of primary hyperparathyroidism. At least one abnormal focus on either 18 F-fluorocholine or 99m Tc-MIBI/tetrofosmin corresponding to a parathyroid gland or ectopic parathyroid tissue was considered as a positive finding. In 76 patients with positive findings on at least one imaging modality, surgical exploration was performed within 6 months, and the results were related to histopathological findings and clinical and laboratory findings at 3-6 months as the standard of truth. In 24 patients, no surgery was performed: in 18 patients with positive imaging findings surgery was refused or considered risky, and in 6 patients imaging was negative. Therefore, data from 82 patients (76 undergoing surgery, 6 without surgery) in whom the standard of truth criteria were met, were used in the final analysis. All patients showed biochemical evidence of primary hyperparathyroidism with a mean serum calcium level of 2.78 ± 0.34 mmol/l and parathormone (PTH) level of 196.5 ± 236.4 pg/ml. The study results in 76 patients with verified histopathology and 3 patients with negative imaging findings were analysed. Three of six patients with negative imaging showed normalized serum PTH and calcium levels on laboratory follow-up at 3 and 6 months, and the results were considered true negative. In a patient-based analysis, the detection rate with 18 F-fluorocholine PET/CT was 93% (76/82), but was only 61% (50/82) with 99m Tc-MIBI/tetrofosmin SPECT/CT. In a lesion-based analysis, the

  8. Reproducibility of geometrical acquisition of intra-thoracic organs of children on CT scans.

    PubMed

    Coulongeat, François; Jarrar, Mohamed-Salah; Serre, Thierry; Thollon, Lionel

    2011-08-01

    This paper analyses geometry of intra-thoracic organs from computed tomography (CT) scans performed on 20 children aged from 4 months to 16 years. A set of two measurements on lungs and heart were performed by the same observer. A third set was performed by a second observer. Thus, the intra- and inter-observer relative deviation of measurements was analysed. Multiple regressions were used in order to study the relationship between the CT properties (scanner, voltage, dose, pixel size, slice increment) and the relative deviation of measurements. There is a very low systematic intra- and inter-observer bias in measurements except for the volume of the heart. None of the CT data properties has a significant influence on the relative deviation of measurement. In the present paper, the measurements and 3D reconstruction protocol described can be applied to characterise the growth of the intra-thoracic organs.

  9. Cervical tuberculous adenitis: CT manifestations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reede, D.L.; Bergeron, R.T.

    1985-03-01

    Cervical tuberculous adenitis is being seen with increasing frequency in the United States; in the appropriate clinical setting it should be included in the differential diagnosis of an asymptomatic neck mass. Patients are typically young adults who are recent arrivals from Southeast Asia. A history of tuberculosis is not always elicited nor is the chest radiograph always abnormal. All of these patients have positive purified protein derivative tests unless they are anergic. The CT findings may lead to the diagnosis. Several CT patterns of nodal disease can be seen in tuberculous adenitis; some may mimic benign and neoplastic disease. Themore » presence of a multiloculated or multichambered (conglomerate nodal) mass with central lucency and thick rims of enhancement and minimally effaced fascial planes is highly suggestive of tuberculous adenitis, especially if the patient has a strongly positive tuberculosis skin test.« less

  10. Anisakiasis presenting to the ED: clinical manifestations, time course, hematologic tests, computed tomographic findings, and treatment.

    PubMed

    Takabayashi, Takeshi; Mochizuki, Toshiaki; Otani, Norio; Nishiyama, Kei; Ishimatsu, Shinichi

    2014-12-01

    The prevalence of anisakiasis is rare in the United States and Europe compared with that in Japan, with few reports of its presentation in the emergency department (ED). This study describes the clinical, hematologic, computed tomographic (CT) characteristics, and treatment in gastric and small intestinal anisakiasis patients in the ED. We retrospectively reviewed the data of 83 consecutive anisakiasis presentations in our ED between 2003 and 2012. Gastric anisakiasis was endoscopically diagnosed with the Anisakis polypide. Small intestinal anisakiasis was diagnosed based on both hematologic (Anisakis antibody) and CT findings. Of the 83 cases, 39 had gastric anisakiasis and 44 had small intestinal anisakiasis based on our diagnostic criteria. Although all patients had abdominal pain, the gastric anisakiasis group developed symptoms significantly earlier (peaking within 6 hours) than the small intestinal anisakiasis group (peaking within 48 hours), and fewer patients with gastric anisakiasis needed admission therapy (5% vs 57%, P<.01). All patients in the gastric and 40 (91%) in the small intestinal anisakiasis group had a history of raw seafood ingestion. Computed tomographic findings revealed edematous wall thickening in all patients, and ascites and phlegmon of the mesenteric fat were more frequently observed in the small intestinal anisakiasis group. In the ED, early and accurate diagnosis of anisakiasis is important to treat and explain to the patient, and diagnosis can be facilitated by a history of raw seafood ingestion, evaluation of the time-to-symptom development, and classic CT findings. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. 68Ga-PSMA PET/CT in the evaluation of bone metastases in prostate cancer.

    PubMed

    Sachpekidis, Christos; Bäumer, P; Kopka, K; Hadaschik, B A; Hohenfellner, M; Kopp-Schneider, A; Haberkorn, U; Dimitrakopoulou-Strauss, A

    2018-06-01

    The aims of this retrospective analysis were to compare 68 Ga-PSMA PET findings and low-dose CT findings (120 kV, 30 mA), and to obtain semiquantitative and quantitative 68 Ga-PSMA PET data in patients with prostate cancer (PC) bone metastases. In total, 152 PET/CT scans from 140 patients were evaluated. Of these patients, 30 had previously untreated primary PC, and 110 had biochemical relapse after treatment of primary PC. All patients underwent dynamic PET/CT scanning of the pelvis and lower abdomen as well as whole-body PET/CT with 68 Ga-PSMA-11. The PET/CT scans were analysed qualitatively (visually), semiquantitatively (SUV), and quantitatively based on a two-tissue compartment model and a noncompartmental approach leading to the extraction of the fractal dimension. Differences were considered significant for p values <0.05. In total, 168 68 Ga-PSMA-positive and 113 CT-positive skeletal lesions were detected in 37 patients (8 with primary PC, 29 with biochemical recurrence). Of these 168 lesions, 103 were both 68 Ga-PSMA PET-positive and CT-positive, 65 were only 68 Ga-PSMA-positive, and 10 were only CT-positive. The Yang test showed that there were significantly more 68 Ga-PSMA PET-positive lesions than CT-positive lesions. Association analysis showed that PSA plasma levels were significantly correlated with several 68 Ga-PSMA-11-associated parameters in bone metastases, including the degree of tracer uptake (SUV average and SUV max ), its transport rate from plasma to the interstitial/intracellular compartment (K 1 ), its rate of binding to the PSMA receptor and its internalization (k 3 ), its influx rate (K i ), and its distribution heterogeneity. 68 Ga-PSMA PET/CT is a useful diagnostic tool in the detection of bone metastases in PC. 68 Ga-PSMA PET visualizes more bone metastases than low-dose CT. PSA plasma levels are significantly correlated with several 68 Ga-PSMA PET parameters.

  12. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    PubMed

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  13. 18F-FDOPA PET/CT imaging of MAX-related pheochromocytoma.

    PubMed

    Taïeb, David; Jha, Abhishek; Guerin, Carole; Pang, Ying; Adams, Karen T; Chen, Clara C; Romanet, Pauline; Roche, Philippe; Essamet, Wassim; Ling, Alexander; Quezado, Martha M; Castinetti, Frédéric; Sebag, Fréderic; Pacak, Karel

    2018-03-08

    MYC associated factor X (MAX) has been recently described as a new susceptibility pheochromocytoma (PHEO) gene with a total of approximately 40 reported cases. At present, no study has specifically described the functional imaging phenotype of MAX-related PHEO. The objective of this study was to present our experience with contrast-enhanced CT and 18F-FDOPA PET/CT imaging in 6 consecutive patients (4 at initial diagnosis and 2 at follow-up evaluation) with rare but clinically important MAX-related PHEOs. In 5 patients, 18F-FDOPA was also compared to other radiopharmaceuticals. Patients had 5 different mutations in the MAX gene that caused disruption of Max/Myc interaction and/or abolished interaction with DNA based on in-silico analyses. All but one patient developed bilateral PHEOs during their lifetime. In all cases, 18F-FDOPA PET/CT accurately visualized PHEOs that were often multiple within the same gland or bilateral and detected more adrenal and extradrenal lesions than CT (per lesion sensitivity 90.5% vs 52.4% for CT/MRI). The 2 missed PHEO on 18F-FDOPA PET/CT were <1cm, corresponding to nodular adrenomedullary hyperplasia. 68Ga-DOTATATE PET/CT detected fewer lesions than 18F-FDOPA PET/CT in 1/3 patients and 18F-FDG PET/CT was only faintly positive in 2/4 patients with underestimation of extraadrenal lesions in 1 patient. MAX-related PHEO exihibit a marked 18F-FDOPA uptake, a finding that illustrates the common well-differentiated chromaffin pattern of PHEO associated with activation of kinase signaling pathways. 18F-FDOPA PET/CT should be considered as the first-line functional imaging modality for diagnostic or follow-up evaluation in these patients.

  14. TU-E-217BCD-04: Spectral Breast CT: Effect of Adaptive Filtration on CT Numbers, CT Noise, and CNR.

    PubMed

    Silkwood, J; Matthews, K; Shikhaliev, P

    2012-06-01

    Photon counting spectral breast CT is feasible in part due to using an adaptive filter. An adaptive filter provides flat x-ray intensity profile and constant x-ray energy spectrum across detector surface, decreases required detector count rate, and eliminates beam hardening artifacts. However, the altered x-ray exposure profiles at the breast and detector surface may influence the distribution of CT noise, CT numbers, and contrast to noise ratio (CNR) across the CT images. The purpose of this work was to investigate these effects. Images of a CT phantom with and without adaptive filter were simulated at 60kVp, 90kVp, and 120kVp tube voltages and 660 mR total skin exposure. The CT phantom with water content had 14cm diameter, contrast elements representing adipose tissue and 2.5mg/cc iodine contrast located at 1cm, 3.5cm, and 6cm from center of the phantom. The CT numbers, CT noise, and CNR were measured at multiple locations for several filter/exposure combinations: (1)without adaptive filter for 660mR skin exposure; (2)with adaptive filter for 660mR skin exposure along central axis (mean skin exposure across the breast was <660mR); and (3)with adaptive filter for scaled exposure (mean skin exposure was 660mR). Beam hardening (cupping) artifacts had 47HU magnitude without adaptive filter but were eliminated with adaptive filter. CNR of contrast elements was comparable for (1) and (2) over central parts but was higher by 20-30% for (1) near the edge of the phantom. CNR was higher by 20-30% in (3) as compared to (2) over central parts and comparable near the edges. The adaptive filter provided: uniform distribution of CT noise, CNR, and CT numbers across CT images; comparable or better CNR with no dose penalty to the breast; and eliminated beam hardening artifacts. © 2012 American Association of Physicists in Medicine.

  15. CT scan

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003330.htm CT scan To use the sharing features on this page, please enable JavaScript. A computed tomography (CT) scan is an imaging method that uses x- ...

  16. Fluorine-18-fluoroethylcholine PET/CT in the detection of prostate cancer: a South African experience.

    PubMed

    Vorster, Mariza; Modiselle, Moshe; Ebenhan, Thomas; Wagener, Carl; Sello, That; Zeevaart, Jan Rijn; Moshokwa, Evelyn; Sathekge, Mike Machaba

    2015-01-01

    Imaging with fluorine-18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) has, until recently provided disappointing results with low sensitivity ranging from 31%-64% in patients with well-differentiated prostate cancer (PC) at all prostatic specific antigen (PSA) levels while fluorine-18-fluoroethylcholine ((18)F-FECh) PET/CT showed about 85% sensitivity in restaging patients after relapse. We present our experience of the sensitivity of (18)F-FECh PET/CT in the early stages of PC. Fifty patients were prospectively recruited and imaged, of which 40 fulfilled all inclusion criteria. Our patients had an average age of 65.5 years. Fifteen patients were referred for initial staging, with the remaining 25 referred for restaging and all patients had histologically confirmed adenocarcinoma. Patients were imaged by (18)F-FECh PET/CT. Findings were evaluated qualitatively and quantitatively and compared to the results of histology, PSA, Gleason score and bone scintigraphy. The prostate SUVmax was also used. Thirty-one patients demonstrated abnormal pelvic- and or extra- pelvic findings on (18)F-FECh PET/CT, which was consistent with malignant or metastatic involvement. The prostate SUVmax could not be used to predict the presence or absence of metastatic disease. Findings of this paper suggest that (18)F-FECh PET/CT in 30/40 cases (estimated as 75%) was helpful in the initial staging, restaging and lymph node detection of patients with PC. The SUVmax was not helpful. We diagnosed more PC cases in our African-American patients as compared to the Caucasian patients.

  17. CT Perfusion of the Head

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z CT Perfusion of the Head Computed tomography (CT) perfusion ... of CT Perfusion of the Head? What is CT Perfusion of the Head? Computed tomography (CT) perfusion ...

  18. Diagnostic sensitivity of Tc-99m HYNIC PSMA SPECT/CT in prostate carcinoma: A comparative analysis with Ga-68 PSMA PET/CT.

    PubMed

    Lawal, Ismaheel O; Ankrah, Alfred O; Mokgoro, Neo P; Vorster, Mariza; Maes, Alex; Sathekge, Mike M

    2017-08-01

    Emerging data from published studies are demonstrating the superiority of Ga-68 PSMA PET/CT imaging in prostate cancer. However, the low yield of the Ge-68/Ga-68 from which Gallium-68 is obtained and fewer installed PET/CT systems compared to the SPECT imaging systems may limit its availability. We, therefore, evaluated in a head-to-head comparison, the diagnostic sensitivity of Ga-68 PSMA PET/CT and Tc-99m PSMA SPECT/CT in patients with prostate cancer. A total of 14 patients with histologically confirmed prostate cancer were prospectively recruited to undergo Ga-68 PSMA PET/CT and Tc-99m HYNIC PSMA SPECT/CT. The mean age of patients was 67.21 ± 8.15 years and the median PSA level was 45.18 ng/mL (range = 1.51-687 ng/mL). SUVmax of all lesions and the size of lymph nodes with PSMA avidity on Ga-68 PSMA PET/CT were determined. Proportions of these lesions detected on Tc-99m HYNIC PSMA SPECT/CT read independent of PET/CT findings were determined. A total of 46 lesions were seen on Ga-68 PSMA PET/CT localized to the prostate (n = 10), lymph nodes (n = 24), and bones (n = 12). Of these, Tc-99m HYNIC PSMA SPECT/CT detected 36 lesions: Prostate = 10/10 (100%), lymph nodes = 15/24 (62.5%), and bones = 11/12 (91.7%) with an overall sensitivity of 78.3%. Lesions detected on Tc-99m HYNIC PSMA SPECT/CT were bigger in size (P < 0.001) and had higher SUVmax (P < 0.001) as measured on Ga-68 PSMA PET/CT compared to those lesions that were not detected. All lymph nodes greater than 10 mm in size were detected while only 28% of nodes less than 10 mm were detected by Tc-99m HYNIC PSMA SPECT/CT. In a univariate analysis, Lymph node size (P = 0.033) and the SUVmax of all lesions (P = 0.007) were significant predictors of lesion detection on Tc-99m HYNIC PSMA SPECT/CT. Tc-99m HYNIC PSMA may be a useful in imaging of prostate cancer although with a lower sensitivity for lesion detection compared to Ga-68 PSMA PET/CT. Its use is

  19. [Magnetic resonance imaging in facial injuries and digital fusion CT/MRI].

    PubMed

    Kozakiewicz, Marcin; Olszycki, Marek; Arkuszewski, Piotr; Stefańczyk, Ludomir

    2006-01-01

    Magnetic resonance images [MRI] and their digital fusion with computed tomography [CT] data, observed in patients affected with facial injuries, are presented in this study. The MR imaging of 12 posttraumatic patients was performed in the same plains as their previous CT scans. Evaluation focused on quality of the facial soft tissues depicting, which was unsatisfactory in CT. Using the own "Dental Studio" programme the digital fusion of the both modalities was performed. Pathologic dislocations and injures of facial soft tissues are visualized better in MRI than in CT examination. Especially MRI properly reveals disturbances in intraorbital soft structures. MRI-based assessment is valuable in patients affected with facial soft tissues injuries, especially in case of orbita/sinuses hernia. Fusion CT/MRI scans allows to evaluate simultaneously bone structure and soft tissues of the same region.

  20. CT Scans

    MedlinePlus

    ... cross-sectional pictures of your body. Doctors use CT scans to look for Broken bones Cancers Blood clots Signs of heart disease Internal bleeding During a CT scan, you lie still on a table. The table ...

  1. Advances in Pancreatic CT Imaging.

    PubMed

    Almeida, Renata R; Lo, Grace C; Patino, Manuel; Bizzo, Bernardo; Canellas, Rodrigo; Sahani, Dushyant V

    2018-07-01

    The purpose of this article is to discuss the advances in CT acquisition and image postprocessing as they apply to imaging the pancreas and to conceptualize the role of radiogenomics and machine learning in pancreatic imaging. CT is the preferred imaging modality for assessment of pancreatic diseases. Recent advances in CT (dual-energy CT, CT perfusion, CT volumetry, and radiogenomics) and emerging computational algorithms (machine learning) have the potential to further increase the value of CT in pancreatic imaging.

  2. Micro-CT measurements of tumoral vessels supplied by portal circulation in hepatic colorectal metastasis mouse model.

    PubMed

    Jun, Hong Young; Lee, Young Hwan; Juhng, Seon Kwan; Lee, Myeung Su; Oh, Jaemin; Yoon, Kwon-Ha

    2014-06-01

    The purpose of this study was to elucidate the micro CT findings of tumoral vessels supplied by portal circulation during establishment of hepatic metastasis of colorectal cancer in a mouse model. Hepatic metastases were induced in 15 BALB/c mice through the injection of murine colonic adenocarcinoma tumor cells into the mesenteric vein. Micro-CT imaging of the tumoral vessels was obtained to clarify the microvascular architecture. We evaluated the sinusoidal structure, diameter of the tumoral vessels (DTV) and blood vessel density (BVD) according to tumor sizes ranging from 201 to 3,000 µm in diameter. A total of 116 tumors were observed on day 15 after cell injection. The mean diameter of a normal hepatic sinusoid was 11.7 ± 2.0 µm on micro CT. The DTV supplied by the portal vein of tumors measuring 1,001-1,500 µm in diameter was greater than that of tumors 200-1,000 µm in diameter. The mean BVD from the portal vein gradually decrease according to size of tumor from 201 to 3,000 µm in diameter (r(2)  = -0.584, P < 0.01). The characteristics of tumoral vessels supplied by portal circulation during establishment of hepatic colorectal metastases were well visualized with micro-CT imaging. © 2014 Wiley Periodicals, Inc.

  3. Associations between observed neighborhood characteristics and physical activity: findings from a multiethnic urban community

    PubMed Central

    Kwarteng, Jamila L.; Schulz, Amy J.; Mentz, Graciela B.; Zenk, Shannon N.; Opperman, Alisha A.

    2014-01-01

    Background There is growing interest in the contributions of characteristics of the neighborhood environment to inequalities in physical activity. However, few studies have examined the relationship between observed neighborhood environmental characteristics and physical activity in a multiethnic urban area. Purpose The purpose of this study was to assess relationships between neighborhood environments and physical activity and the extent to which these associations varied by demographic characteristics or perceptions of the physical and social environment. Methods Cross-sectional analyses drew upon data collected from a stratified proportional probability sample of non-Hispanic Black, Hispanic and non-Hispanic White (NHW) adults (n = 919) in low-to-moderate income neighborhoods in Detroit, Michigan. Physical activity was assessed as self-reported duration and frequency of vigorous and moderate physical activity. Observed physical environment was assessed through systematic social observation by trained observers on blocks adjacent to survey respondents' residences. Results We find a positive association of sidewalk condition with physical activity, with stronger effects for younger compared with older residents. In addition, physical disorder was more negatively associated with physical activity among NHW and older residents. Conclusions These findings suggest that sidewalk improvements and reductions in physical disorder in urban communities may promote greater equity in physical activity. PMID:24159053

  4. Improving the imaging of calcifications in CT by histogram-based selective deblurring

    NASA Astrophysics Data System (ADS)

    Rollano-Hijarrubia, Empar; van der Meer, Frits; van der Lugt, Add; Weinans, Harrie; Vrooman, Henry; Vossepoel, Albert; Stokking, Rik

    2005-04-01

    Imaging of small high-density structures, such as calcifications, with computed tomography (CT) is limited by the spatial resolution of the system. Blur causes small calcifications to be imaged with lower contrast and overestimated volume, thereby hampering the analysis of vessels. The aim of this work is to reduce the blur of calcifications by applying three-dimensional (3D) deconvolution. Unfortunately, the high-frequency amplification of the deconvolution produces edge-related ring artifacts and enhances noise and original artifacts, which degrades the imaging of low-density structures. A method, referred to as Histogram-based Selective Deblurring (HiSD), was implemented to avoid these negative effects. HiSD uses the histogram information to generate a restored image in which the low-intensity voxel information of the observed image is combined with the high-intensity voxel information of the deconvolved image. To evaluate HiSD we scanned four in-vitro atherosclerotic plaques of carotid arteries with a multislice spiral CT and with a microfocus CTCT), used as reference. Restored images were generated from the observed images, and qualitatively and quantitatively compared with their corresponding μCT images. Transverse views and maximum-intensity projections of restored images show the decrease of blur of the calcifications in 3D. Measurements of the areas of 27 calcifications and total volumes of calcification of 4 plaques show that the overestimation of calcification was smaller for restored images (mean-error: 90% for area; 92% for volume) than for observed images (143%; 213%, respectively). The qualitative and quantitative analyses show that the imaging of calcifications in CT can be improved considerably by applying HiSD.

  5. Attenuation correction of emission PET images with average CT: Interpolation from breath-hold CT

    NASA Astrophysics Data System (ADS)

    Huang, Tzung-Chi; Zhang, Geoffrey; Chen, Chih-Hao; Yang, Bang-Hung; Wu, Nien-Yun; Wang, Shyh-Jen; Wu, Tung-Hsin

    2011-05-01

    Misregistration resulting from the difference of temporal resolution in PET and CT scans occur frequently in PET/CT imaging, which causes distortion in tumor quantification in PET. Respiration cine average CT (CACT) for PET attenuation correction has been reported to improve the misalignment effectively by several papers. However, the radiation dose to the patient from a four-dimensional CT scan is relatively high. In this study, we propose a method to interpolate respiratory CT images over a respiratory cycle from inhalation and exhalation breath-hold CT images, and use the average CT from the generated CT set for PET attenuation correction. The radiation dose to the patient is reduced using this method. Six cancer patients of various lesion sites underwent routine free-breath helical CT (HCT), respiration CACT, interpolated average CT (IACT), and 18F-FDG PET. Deformable image registration was used to interpolate the middle phases of a respiratory cycle based on the end-inspiration and end-expiration breath-hold CT scans. The average CT image was calculated from the eight interpolated CT image sets of middle respiratory phases and the two original inspiration and expiration CT images. Then the PET images were reconstructed by these three methods for attenuation correction using HCT, CACT, and IACT. Misalignment of PET image using either CACT or IACT for attenuation correction in PET/CT was improved. The difference in standard uptake value (SUV) from tumor in PET images was most significant between the use of HCT and CACT, while the least significant between the use of CACT and IACT. Besides the similar improvement in tumor quantification compared to the use of CACT, using IACT for PET attenuation correction reduces the radiation dose to the patient.

  6. Small-animal CT: Its difference from, and impact on, clinical CT

    NASA Astrophysics Data System (ADS)

    Ritman, Erik L.

    2007-10-01

    For whole-body computed tomography (CT) images of small rodents, a voxel resolution of at least 10 -3 mm 3 is needed for scale-equivalence to that currently achieved in clinical CT scanners (˜1 mm 3) in adult humans. These "mini-CT" images generally require minutes rather than seconds to complete a scan. The radiation exposure resulting from these mini-CT scans, while higher than clinical CT scans, is below the level resulting in acute tissue damage. Hence, these scans are useful for performing clinical-type diagnostic and monitoring scans for animal models of disease and their response to treatment. "Micro-CT", with voxel size <10 -5 mm 3, has been useful for imaging isolated, intact organs at an almost cellular level of resolution. Micro-CT has the great advantage over traditional microscopic methods in that it generates detailed three-dimensional images in relatively large, opaque volumes such as an intact rodent heart or kidney. The radiation exposure needed in these scans results in acute tissue damage if used in living animals. Experience with micro-CT is contributing to exploration of new applications for clinical CT imaging by providing insights into different modes of X-ray image formation as follows: Spatial resolution should be sufficient to detect an individual Basic Functional Unit (BFU, the smallest collection of diverse cells, such as hepatic lobule, that behaves like the organ), which requires voxels ˜10 -3 mm 3 in volume, so that the BFUs can be counted. Contrast resolution sufficient to allow quantitation of: New microvascular growth, which manifests as increased tissue contrast due to X-ray contrast agent in those vessels' lumens during passage of injected contrast agent in blood. Impaired endothelial integrity which manifests as increased opacification and delayed washout of contrast from tissues. Discrimination of pathological accumulations of metals such as Fe and Ca, which occur in the arterial wall following hemorrhage or tissue damage

  7. Frequency and Clinical Significance of Previously Undetected Incidental Findings Detected on Computed Tomography Simulation Scans for Breast Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakamura, Naoki, E-mail: naokinak@luke.or.jp; Tsunoda, Hiroko; Takahashi, Osamu

    2012-11-01

    Purpose: To determine the frequency and clinical significance of previously undetected incidental findings found on computed tomography (CT) simulation images for breast cancer patients. Methods and Materials: All CT simulation images were first interpreted prospectively by radiation oncologists and then double-checked by diagnostic radiologists. The official reports of CT simulation images for 881 consecutive postoperative breast cancer patients from 2009 to 2010 were retrospectively reviewed. Potentially important incidental findings (PIIFs) were defined as any previously undetected benign or malignancy-related findings requiring further medical follow-up or investigation. For all patients in whom a PIIF was detected, we reviewed the clinical recordsmore » to determine the clinical significance of the PIIF. If the findings from the additional studies prompted by a PIIF required a change in management, the PIIF was also recorded as a clinically important incidental finding (CIIF). Results: There were a total of 57 (6%) PIIFs. The 57 patients in whom a PIIF was detected were followed for a median of 17 months (range, 3-26). Six cases of CIIFs (0.7% of total) were detected. Of the six CIIFs, three (50%) cases had not been noted by the radiation oncologist until the diagnostic radiologist detected the finding. On multivariate analysis, previous CT examination was an independent predictor for PIIF (p = 0.04). Patients who had not previously received chest CT examinations within 1 year had a statistically significantly higher risk of PIIF than those who had received CT examinations within 6 months (odds ratio, 3.54; 95% confidence interval, 1.32-9.50; p = 0.01). Conclusions: The rate of incidental findings prompting a change in management was low. However, radiation oncologists appear to have some difficulty in detecting incidental findings that require a change in management. Considering cost, it may be reasonable that routine interpretations are given to those who

  8. The early use of PET-CT alters the management of patients with esophageal cancer.

    PubMed

    Williams, R N; Ubhi, S S; Sutton, C D; Thomas, A L; Entwisle, J J; Bowrey, D J

    2009-05-01

    The routine use of positron emission tomography-computed tomography (PET-CT) in the staging of patients with esophageal carcinoma remains contentious, with conflicting reports of its benefit. In our unit, PET-CT has been used routinely in the staging of all patients considered for radical therapy (surgery or chemoradiotherapy). Our aim was to determine the frequency with which PET-CT influenced decision making in the management of patients with carcinoma of the esophagus or gastroesophageal junction. CT, PET-CT, and outcome information were collected on 38 patients considered for radical therapy. Patient proformas, with and without PET-CT findings, were constructed and each independently reviewed in a randomized and blinded fashion by five multidisciplinary team members (three surgeons, two oncologists) and a treatment strategy determined. PET-CT changed the staging for ten patients (26%). This translated into a change in management decision for seven patients (18%). The concordance between individual management plans and treatment intent was 79% for CT (150 of 190 decisions) and it was 92% for PET-CT (175 of 190 decisions). Full concordance between multidisciplinary team members was 66% with CT staging and 74% with the addition of PET-CT. The use of PET-CT early in the staging algorithm for esophageal carcinoma altered the staging for a quarter of patients and the management for a fifth of patients, supporting its inclusion early in the staging algorithm.

  9. Anatomic and Quantitative Temporal Bone CT for Preoperative Assessment of Branchio-Oto-Renal Syndrome.

    PubMed

    Ginat, D T; Ferro, L; Gluth, M B

    2016-12-01

    We describe the temporal bone computed tomography (CT) findings of an unusual case of branchio-oto-renal syndrome with ectopic ossicles that are partially located in the middle cranial fossa. We also describe quantitative temporal bone CT assessment pertaining to cochlear implantation in the setting of anomalous cochlear anatomy associated with this syndrome.

  10. The diagnostic performance and added value of (18)F-FDG PET/CT in the detection of liver metastases in recurrent colorectal carcinoma patients.

    PubMed

    Odalovic, Strahinja; Artiko, Vera; Sobic-Saranovic, Dragana; Stojiljkovic, Milica; Petrovic, Milorad; Petrovic, Nebojsa; Kozarevic, Nebojsa; Grozdic-Milojevic, Isidora; Obradovic, Vladimir

    2015-01-01

    The aim of this study was to assess the value of (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT in detection of liver metastases in patients with suspected recurrent colorectal carcinoma, as well as to compare diagnostic performance of (18)F-FDG PET/CT with conventional imaging methods (MDCT). This study included 73 patients with resected primary colorectal adenocarcinoma referred for (18)F-FDG PET/CT to the National PET Center, at the Clinical Center of Serbia, Belgrade, from January 2010 to May 2013, with suspicion of recurrence. The patients underwent (18)F-FDG PET/CT examination on a 64-slice hybrid PET/CT scanner (Biograph, TruePoint64, Siemens Medical Solutions, Inc. USA). Prior to (18)F-FDG PET/CT all patients underwent contrast-enhanced MDCT. Findings of (18)F-FDG PET/CT and MDCT were compared to findings of subsequent histopathological examinations or with results of clinical and imaging follow-up over at least six months. Final diagnosis of liver metastases of colorectal cancer was made either by histopathological examination of specimen after biopsy or surgery, or based on clinical, laboratory and imaging evaluation during first six months after PET/CT scan. In detection of liver metastases (18)F-FDG PET/CT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 83.3%, 95.3%, 92.6%, 89.1% and 90.4%, respectively. In addition, MDCT showed sensitivity, specificity, positive predictive value, negative predictive value and accuracy in detection of liver metastases of 60%, 88.4%, 78.3%, 76% and 76.7%, respectively. There was significant difference in sensitivity (83.3% vs 60%; P=0.045) between these two methods. In addition, significant difference was observed in accuracy between PET/CT and MDCT (90.4% vs 76.7%; P=0.016). The higher specificity in visualization of liver metastases was also achieved by (18)F-FDG PET/CT compared to MDCT (95.3% vs 88.4%), but this difference was not significant (P=0.37). (18)F-FDG PET/CT

  11. Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT.

    PubMed

    Pan, Tinsu

    2005-02-01

    We proposed a data sufficiency condition (DSC) for four-dimensional-CT (4D-CT) imaging on a multislice CT scanner, designed a pitch factor for a helical 4D-CT, and compared the acquisition time, slice sensitivity profile (SSP), effective dose, ability to cope with an irregular breathing cycle, and gating technique (retrospective or prospective) of the helical 4D-CT and the cine 4D-CT on the General Electric (GE) LightSpeed RT (4-slice), Plus (4-slice), Ultra (8-slice) and 16 (16-slice) multislice CT scanners. To satisfy the DSC, a helical or cine 4D-CT acquisition has to collect data at each location for the duration of a breathing cycle plus the duration of data acquisition for an image reconstruction. The conditions for the comparison were 20 cm coverage in the cranial-caudal direction, a 4 s breathing cycle, and half-scan reconstruction. We found that the helical 4D-CT has the advantage of a shorter scan time that is 10% shorter than that of the cine 4D-CT, and the disadvantages of 1.8 times broadening of SSP and requires an additional breathing cycle of scanning to ensure an adequate sampling at the start and end locations. The cine 4D-CT has the advantages of maintaining the same SSP as slice collimation (e.g., 8 x 2.5 mm slice collimation generates 2.5 mm SSP in the cine 4D-CT as opposed to 4.5 mm in the helical 4D-CT) and a lower dose by 4% on the 8- and 16-slice systems, and 8% on the 4-slice system. The advantage of faster scanning in the helical 4D-CT will diminish if a repeat scan at the location of a breathing irregularity becomes necessary. The cine 4D-CT performs better than the helical 4D-CT in the repeat scan because it can scan faster and is more dose efficient.

  12. Computed tomographic findings in dogs and cats with temporomandibular joint disorders: 58 cases (2006-2011).

    PubMed

    Arzi, Boaz; Cissell, Derek D; Verstraete, Frank J M; Kass, Philip H; DuRaine, Grayson D; Athanasiou, Kyriacos A

    2013-01-01

    To describe CT findings in dogs and cats with temporomandibular joint (TMJ) disorders. Retrospective case series. 41 dogs and 17 cats. Medical records and CT images of the skull were reviewed for dogs and cats that were examined at a dentistry and oral surgery specialty practice between 2006 and 2011. Of 142 dogs and 42 cats evaluated, 41 dogs and 17 cats had CT findings consistent with a TMJ disorder. In dogs, the most common TMJ disorder was osteoarthritis; however, in most cases, there were other TMJ disorders present in addition to osteoarthritis. Osteoarthritis was more frequently identified at the medial aspect rather than the lateral aspect of the TMJ, whereas the frequency of osteoarthritic involvement of the dorsal and ventral compartments did not differ significantly. In cats, fractures were the most common TMJ disorder, followed by osteoarthritis. Clinical signs were observed in all dogs and cats with TMJ fractures, dysplasia, ankylosis, luxation, and tumors; however, only 4 of 15 dogs and 2 of 4 cats with osteoarthritis alone had clinical signs. Results indicated that TMJ disorders were frequently present in combination. Osteoarthritis was the most common TMJ disorder in dogs and the second most common TMJ disorder in cats. Computed tomography should be considered as a tool for the diagnosis of TMJ disorders in dogs and cats with suspected orofacial disorders and signs of pain. (J Am Vet Med Assoc 2013;242:69-75).

  13. Retrospective evaluation of thoracic computed tomography findings in dogs naturally infected by Angiostrongylus vasorum.

    PubMed

    Coia, Mark E; Hammond, Gawain; Chan, Daniel; Drees, Randi; Walker, David; Murtagh, Kevin; Stone, Janine; Bexfield, Nicholas; Reeve, Lizzie; Helm, Jenny

    2017-09-01

    Angiostrongylus vasorum (A. vasorum) is an important emerging disease of canidae. Cardiorespiratory signs are common in affected dogs, therefore thoracic imaging is critical for diagnosing and monitoring disease. Descriptions of thoracic computed tomography (CT) findings in dogs naturally infected with A. vasorum are currently lacking. Aims of this multicenter, retrospective study were to describe thoracic CT findings in a group of dogs with confirmed disease, determine whether any changes were consistent among dogs, and propose standardized terms for describing thoracic CT findings. Nine UK-based referral centers' clinical and imaging databases were searched for dogs that had a confirmed diagnosis of A. vasorum, and had undergone thoracic CT examination. Eighteen dogs, from seven of the centers, fulfilled the inclusion criteria. The lung lobes were divided into the following three zones and the CT changes described in each: pleural (zone 1), subpleural (zone 2), and peribronchovascular (zone 3). The predominent abnormality was increased lung attenuation due to poorly defined ground-glass opacity or consolidation. There were regions of mosaic attenuation due to peripheral bronchiectasis. Nine/18 (50%) dogs showed hyperattenuating nodules of varying sizes with ill-defined margins. The distribution always affected zones 1 and 2 with varied involvement of zone 3; this resulted in clear delineation between zones 2 and 3. Tracheobronchial lymphadenomegaly was frequently noted. Findings were nonspecific and there was considerable overlap with other pulmonary conditions. However, authors recommend that A. vasorum be considered a likely differential diagnosis for dogs with a predominantly peripheral distribution of lung changes. © 2017 American College of Veterinary Radiology.

  14. Chest CT scans are frequently abnormal in asymptomatic patients with newly diagnosed acute myeloid leukemia.

    PubMed

    Vallipuram, Janaki; Dhalla, Sidika; Bell, Chaim M; Dresser, Linda; Han, Heekyung; Husain, Shahid; Minden, Mark D; Paul, Narinder S; So, Miranda; Steinberg, Marilyn; Vallipuram, Mayuran; Wong, Gary; Morris, Andrew M

    2017-04-01

    Chest computed tomography (CT) findings of nodules, ground glass opacities, and consolidations are often interpreted as representing invasive fungal infection in individuals with febrile neutropenia. We assessed whether these CT findings were present in asymptomatic individuals with acute myeloid leukemia (AML) at low risk of invasive fungal disease. A retrospective study of consecutive asymptomatic adult patients with newly diagnosed AML over a 2-year period was performed at a tertiary care oncology center. Radiology reports of baseline chest CTs were reviewed. Of 145 CT scans, the majority (88%) had pulmonary abnormalities. Many (70%) had one or both of unspecified opacities (52%) and nodules (49%). Ground glass opacities (18%) and consolidations (12%) occurred less frequently. Radiologists suggested pneumonia as a possible diagnosis in 32% (n = 47) of scans. Chest CT may result in over-diagnosis of invasive fungal disease in individuals with febrile neutropenia if interpreted without correlation to the patients' clinical status.

  15. Urinary excretion of orally ingested gastrografin on CT.

    PubMed

    Apter, S; Gayer, G; Amitai, M; Hertz, M

    1998-01-01

    Renal excretion of orally ingested gastrografin has rarely been reported on computed tomography (CT). We studied the unenhanced scans of 82 patients with bowel disorders or perforation to assess the prevalence of urinary contrast material (CM) in various bowel diseases. We also assessed the clinical significance of this sign. In addition, we reviewed the unenhanced CT scans of 100 randomly selected patients without bowel diseases as a control group. Twenty-nine of the 58 patients with bowel diseases, six of nine with free perforation, and one of 15 with covered perforation had CM in the urinary tract. None of the 100 without bowel disease showed urinary CM. Statistical analysis was done by using the Fisher's exact test. The prevalence of urinary CM was highest in inflammatory bowel disease, radiation enteritis, and free perforation (p < 0. 0001). This study shows that the CT finding of orally ingested gastrografin in the urinary tract differentiates patients with bowel disease from those without.

  16. A Survey of Direct Users and Uses of SNOMED CT: 2010 Status

    PubMed Central

    Elhanan, Gai; Perl, Yehoshua; Geller, James

    2010-01-01

    SNOMED CT is gaining momentum and endorsements as an international clinical terminology. However, many vendors await a clearer business case and clients’ demand. We conducted a survey of direct users of SNOMED CT to determine the current profile of users, modes of use, and attitudes towards different aspects of the terminology. A web-base survey, consisting of 43 questions was distributed in January 2010, and 215 responses were elicited. This paper summarizes findings regarding profiles of users and their SNOMED CT use. The results indicate significant use by non-researchers and by industry and government sectors. Many users are relative newcomers with less than 3 years experience with SNOMED CT, and production-related use was reported by 39% of respondents. Most users are satisfied with the level of content coverage. The results indicate that SNOMED CT has a solid footing in production systems, and that SCT is mostly used for concept searches and clinical coding. PMID:21346970

  17. Systematic Review and Meta-Analysis of CT Features for Differentiating Complicated and Uncomplicated Appendicitis.

    PubMed

    Kim, Hae Young; Park, Ji Hoon; Lee, Yoon Jin; Lee, Sung Soo; Jeon, Jong-June; Lee, Kyoung Ho

    2018-04-01

    Purpose To perform a systematic review and meta-analysis to identify computed tomographic (CT) features for differentiating complicated appendicitis in patients suspected of having appendicitis and to summarize their diagnostic accuracy. Materials and Methods Studies on diagnostic accuracy of CT features for differentiating complicated appendicitis (perforated or gangrenous appendicitis) in patients suspected of having appendicitis were searched in Ovid-MEDLINE, EMBASE, and the Cochrane Library. Overlapping descriptors used in different studies to denote the same image finding were subsumed under a single CT feature. Pooled diagnostic accuracy of the CT features was calculated by using a bivariate random effects model. CT features with pooled diagnostic odds ratios with 95% confidence intervals not including 1 were considered as informative. Results Twenty-three studies were included, and 184 overlapping descriptors for various CT findings were subsumed under 14 features. Of these, 10 features were informative for complicated appendicitis. There was a general tendency for these features to show relatively high specificity but low sensitivity. Extraluminal appendicolith, abscess, appendiceal wall enhancement defect, extraluminal air, ileus, periappendiceal fluid collection, ascites, intraluminal air, and intraluminal appendicolith showed pooled specificity greater than 70% (range, 74%-100%), but sensitivity was limited (range, 14%-59%). Periappendiceal fat stranding was the only feature that showed high sensitivity (94%; 95% confidence interval: 86%, 98%) but low specificity (40%; 95% confidence interval, 23%, 60%). Conclusion Ten informative CT features for differentiating complicated appendicitis were identified in this study, nine of which showed high specificity, but low sensitivity. © RSNA, 2017 Online supplemental material is available for this article.

  18. Contribution of CT scan and CT-guided aspiration in the management of retropharyngeal abscess in children based on a series of 18 cases.

    PubMed

    Martin, C A; Gabrillargues, J; Louvrier, C; Saroul, N; Mom, T; Gilain, L

    2014-11-01

    This study was designed to analyse the contribution of CT scan to the management of retropharyngeal abscess in children and the place of CT-guided percutaneous aspiration as an alternative to surgical drainage. Retrospective study including 18 children with a mean age of 38 months [range: 5-67 months] presenting with retropharyngeal infection between 2006 and 2011. All cases were initially assessed by contrast-enhanced CT scan of the neck. Clinical, radiological treatment and bacteriological data were collected. Radiological results were correlated with surgical and percutaneous aspiration findings (presence or absence of an abscess). The initial CT scan detected 14 abscesses, 3 cases of non-suppurative lymphadenitis and one case of retropharyngeal oedema. One case of non-suppurative lymphadenitis progressed to abscess after failure of antibiotic therapy and was treated surgically. Surgical drainage revealed a purulent collection in 11 cases and no collection in 3 cases. Four CT-guided percutaneous aspirations were successfully performed. Three cases were treated by antibiotics alone (2 cases of lymphadenitis and 1 case of retropharyngeal oedema). Bacteriological examinations revealed the presence of Streptococcus pyogenes in 78.5% of cases. The positive predictive value of the initial CT scan was 78.8% in our series. Contrast-enhanced neck CT scan confirmed the diagnosis of retropharyngeal abscess and the indication for surgical drainage. It must be performed urgently, on admission. When it is decided to treat the patient with antibiotics alone, follow-up imaging should be performed in the absence of improvement 24 to 48 hours after starting antibiotics. CT-guided percutaneous aspiration is both a diagnostic modality confirming abscess formation of an inflammatory lesion of the retropharyngeal space as well as a therapeutic tool, sometimes avoiding the need for surgical drainage. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. Chronic Obstructive Pulmonary Disease: Lobe-based Visual Assessment of Volumetric CT by Using Standard Images—Comparison with Quantitative CT and Pulmonary Function Test in the COPDGene Study

    PubMed Central

    Kim, Song Soo; Lee, Ho Yun; Nevrekar, Dipti V.; Forssen, Anna V.; Crapo, James D.; Schroeder, Joyce D.; Lynch, David A.

    2013-01-01

    Purpose: To provide a new detailed visual assessment scheme of computed tomography (CT) for chronic obstructive pulmonary disease (COPD) by using standard reference images and to compare this visual assessment method with quantitative CT and several physiologic parameters. Materials and Methods: This research was approved by the institutional review board of each institution. CT images of 200 participants in the COPDGene study were evaluated. Four thoracic radiologists performed independent, lobar analysis of volumetric CT images for type (centrilobular, panlobular, and mixed) and extent (on a six-point scale) of emphysema, the presence of bronchiectasis, airway wall thickening, and tracheal abnormalities. Standard images for each finding, generated by two radiologists, were used for reference. The extent of emphysema, airway wall thickening, and luminal area were quantified at the lobar level by using commercial software. Spearman rank test and simple and multiple regression analyses were performed to compare the results of visual assessment with physiologic and quantitative parameters. Results: The type of emphysema, determined by four readers, showed good agreement (κ = 0.63). The extent of the emphysema in each lobe showed good agreement (mean weighted κ = 0.70) and correlated with findings at quantitative CT (r = 0.75), forced expiratory volume in 1 second (FEV1) (r = −0.68), FEV1/forced vital capacity (FVC) ratio (r = −0.74) (P < .001). Agreement for airway wall thickening was fair (mean κ = 0.41), and the number of lobes with thickened bronchial walls correlated with FEV1 (r = −0.60) and FEV1/FVC ratio (r = −0.60) (P < .001). Conclusion: Visual assessment of emphysema and airways disease in individuals with COPD can provide reproducible, physiologically substantial information that may complement that provided by quantitative CT assessment. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120385/-/DC

  20. 18F-FDG PET/CT in breast cancer: Evidence-based recommendations in initial staging.

    PubMed

    Caresia Aroztegui, Ana Paula; García Vicente, Ana María; Alvarez Ruiz, Soledad; Delgado Bolton, Roberto Carlos; Orcajo Rincon, Javier; Garcia Garzon, Jose Ramon; de Arcocha Torres, Maria; Garcia-Velloso, Maria Jose

    2017-10-01

    Current guidelines do not systematically recommend 18F-FDG PET/CT for breast cancer staging; and the recommendations and level of evidence supporting its use in different groups of patients vary among guidelines. This review summarizes the evidence about the role of 18F-FDG PET/CT in breast cancer staging and the therapeutic and prognostic impact accumulated in the last decade. Other related aspects, such as the association of metabolic information with biology and prognosis are considered and evidence-based recommendations for the use of 18F-FDG PET/CT in breast cancer staging are offered. We systematically searched MEDLINE for articles reporting studies with at least 30 patients related to clinical questions following the Problem/Population, Intervention, Comparison, and Outcome framework. We critically reviewed the selected articles and elaborated evidence tables structuring the summarized information into methodology, results, and limitations. The level of evidence and the grades of recommendation for the use of 18F-FDG PET/CT in different contexts are summarized. Level III evidence supports the use of 18F-FDG PET/CT for initial staging in patients with recently diagnosed breast cancer; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a weak recommendation in this population. In patients with locally advanced breast cancer, level II evidence supports the use of 18F-FDG PET/CT for initial staging; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a strong recommendation in this population. In patients with recently diagnosed breast cancer, the metabolic information from baseline 18F-FDG PET/CT is associated with tumor biology and has prognostic implications, supported by level II evidence. In conclusion, 18F-FDG PET/CT is not recommended for staging all patients with early breast cancer, although evidence of improved regional and systemic staging supports its use in locally advanced

  1. Fontan-associated liver disease: Spectrum of US findings.

    PubMed

    Bae, Jung Min; Jeon, Tae Yeon; Kim, Jung Sun; Kim, Seokhwi; Hwang, Sook Min; Yoo, So-Young; Kim, Ji Hye

    2016-04-01

    To describe ultrasonography (US) findings of Fontan-associated liver disease (FALD) and to determine whether screening US examinations can identify FALD before biochemical hepatic dysfunction. This retrospective study included 55 patients who underwent Fontan procedure over a 20-year period. Hepatobiliary US findings (n=55), CT or MRI findings (n=19), biochemical hepatic function tests (n=49), and histopathological results (n=4) were analyzed. Images were reviewed focusing on the hepatic parenchymal changes, presence of focal lesions, and signs of portal hypertension. Hepatic parenchymal changes (either heterogeneous echotexture or surface nodularity) evident on US were present in 67% (37/55) and showed positive correlation with the Fontan duration. Hyper-echoic lesions were noted in 35% (19/55) and showed a predilection for multiplicity, small size, right lobe location, and irregular margin on high-frequency transducer. These lesions were not demonstrated by CT or MRI or by low-frequency transducer. Histopathological results of targeted biopsy for hyper-echoic lesions revealed lesser degree of patchy sinusoidal and portal fibrosis than seen in cases with surface nodularity. Abnormal parenchymal enhancement was commonly seen with CT or MRI in 63% (12/19) and hypervascular nodules in 21% (4/19). Most patients (82%, 40/49) showed normal biochemical hepatic function tests, despite the presence of hepatic parenchymal changes on imaging. The common US findings of FALD included heterogeneous parenchymal echotexture, surface nodularity, and hyper-echoic lesions. We suggest that hyper-echoic lesions without surface nodularity detected by high-frequency transducer may represent the early stage of fibrosis. US examination may be useful for identifying the progression of FALD before biochemical hepatic dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Four-Dimensional CT of the Diaphragm in Children: Initial Experience

    PubMed Central

    2018-01-01

    Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days–3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (−1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. −1.1 ± 2.2 mm, p < 0.0001), while the normal diaphragm motion was significantly smaller than the motion of the contralateral normal diaphragm in paralysis (4.5 ± 2.1 mm vs. 7.6 ± 3.8 mm, p = 0.01). Basal lung density change of the affected side was significantly smaller than that of the contralateral side in diaphragm paralysis (89 ± 73 Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66

  3. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    NASA Astrophysics Data System (ADS)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  4. Scrub typhus: radiological and clinical findings in abdominopelvic involvement.

    PubMed

    Kim, Kun Yung; Song, Ji Soo; Park, Eun Hae; Jin, Gong Yong

    2017-03-01

    To describe the clinical and radiological findings of abdominopelvic involvement in scrub typhus. Abdominopelvic computed tomography (CT) of 78 patients with scrub typhus were evaluated by two readers. The presence of gallbladder wall thickening, arterial inhomogeneous enhancement of the liver, periportal edema, splenic infarction, hepatomegaly, splenomegaly, ascites, pleural effusion, and sites of lymphadenopathy were evaluated. Patients were divided into four clinical subgroups according to laboratory findings. Association between imaging findings and subgroups was analyzed by Chi squared test or Fisher's exact test. The most common CT finding was hepatomegaly (74.4%), followed by splenomegaly (66.7%). The majority of patients had at least three areas of abdominopelvic lymphadenopathy (71.8%). Pelvic lymphadenopathy was most commonly seen when eschar was found in the ipsilateral lower extremity (left, n = 5/7; right, n = 8/13). Significant association between hepatic dysfunction and perigastric lymphadenopathy was documented (p = 0.03). Scrub typhus has a spectrum of variable clinical and radiological findings mimicking those of acute hepatitis. Diffuse abdominopelvic lymphadenopathy involving the retroperitoneum and pelvic area may aid in early diagnosis of scrub typhus. Perigastric lymphadenopathy could be a sign of severe scrub typhus combined with hepatic dysfunction.

  5. In vivo quantification of mouse autoimmune arthritis by PET/CT

    PubMed Central

    Kundu-Raychaudhuri, Smriti; Mitra, Anupam; Datta-Mitra, Ananya; Chaudhari, Abhijit J.; Raychaudhuri, Siba P.

    2014-01-01

    Aim To quantify the progression and severity of mouse collagen-induced arthritis (CIA) using an in vivo imaging tool, 18F-fluorodeoxyglucose (18F-FDG) PET/CT, and validate it against gold standard ‘histopathological’ evaluation. Method The PET radiotracer 18F-FDG, a marker for glucose metabolism, was injected in mice at different stages during the development of CIA and the radiotracer distribution was imaged using a PET scanner. A sequential CT scan provided correlated anatomy. Radiotracer concentration was derived from PET/CT images for individual limb joints and on a per-limb basis at different stages of the disease. The imaging outcomes were subjected to correlation analysis with concurrently-measured clinical and histological score. Results Clinical and histological score, and hence disease severity, showed a strong linear correlation (R2=0.71, p=0.001, and R2=0.87, p<0.001, respectively) with radiotracer concentration measured from PET/CT during the progression of CIA. Conclusions The strong positive correlation of the 18F-FDG PET/CT findings with the histopathological evaluation at different stages of the disease suggest the potential of this imaging tool for the non-invasive assessment of progression and severity in mouse autoimmune arthritis. Thus, 18F-FDG PET/CT can be considered as a non invasive tool in preclinical studies for development of novel therapies of inflammatory arthritis. PMID:24965561

  6. Investigation of statistical iterative reconstruction for dedicated breast CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makeev, Andrey; Glick, Stephen J.

    2013-08-15

    Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images weremore » compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially

  7. Investigation of statistical iterative reconstruction for dedicated breast CT

    PubMed Central

    Makeev, Andrey; Glick, Stephen J.

    2013-01-01

    Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue. Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters. Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved

  8. 3D intrathoracic region definition and its application to PET-CT analysis

    NASA Astrophysics Data System (ADS)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2014-03-01

    Recently developed integrated PET-CT scanners give co-registered multimodal data sets that offer complementary three-dimensional (3D) digital images of the chest. PET (positron emission tomography) imaging gives highly specific functional information of suspect cancer sites, while CT (X-ray computed tomography) gives associated anatomical detail. Because the 3D CT and PET scans generally span the body from the eyes to the knees, accurate definition of the intrathoracic region is vital for focusing attention to the central-chest region. In this way, diagnostically important regions of interest (ROIs), such as central-chest lymph nodes and cancer nodules, can be more efficiently isolated. We propose a method for automatic segmentation of the intrathoracic region from a given co-registered 3D PET-CT study. Using the 3D CT scan as input, the method begins by finding an initial intrathoracic region boundary for a given 2D CT section. Next, active contour analysis, driven by a cost function depending on local image gradient, gradient-direction, and contour shape features, iteratively estimates the contours spanning the intrathoracic region on neighboring 2D CT sections. This process continues until the complete region is defined. We next present an interactive system that employs the segmentation method for focused 3D PET-CT chest image analysis. A validation study over a series of PET-CT studies reveals that the segmentation method gives a Dice index accuracy of less than 98%. In addition, further results demonstrate the utility of the method for focused 3D PET-CT chest image analysis, ROI definition, and visualization.

  9. Clinical manifestations that predict abnormal brain computed tomography (CT) in children with minor head injury.

    PubMed

    Alharthy, Nesrin; Al Queflie, Sulaiman; Alyousef, Khalid; Yunus, Faisel

    2015-01-01

    Computed tomography (CT) used in pediatric pediatrics brain injury (TBI) to ascertain neurological manifestations. Nevertheless, this practice is associated with adverse effects. Reports in the literature suggest incidents of morbidity and mortality in children due to exposure to radiation. Hence, it is found imperative to search for a reliable alternative. The aim of this study is to find a reliable clinical alternative to detect an intracranial injury without resorting to the CT. Retrospective cross-sectional study was undertaken in patients (1-14 years) with blunt head injury and having a Glasgow Coma Scale (GCS) of 13-15 who had CT performed on them. Using statistical analysis, the correlation between clinical examination and positive CT manifestation is analyzed for different age-groups and various mechanisms of injury. No statistically significant association between parameteres such as Loss of Consciousness, 'fall' as mechanism of injury, motor vehicle accidents (MVA), more than two discrete episodes of vomiting and the CT finding of intracranial injury could be noted. Analyzed data have led to believe that GCS of 13 at presentation is the only important clinical predictor of intracranial injury. Retrospective data, small sample size and limited number of factors for assessing clinical manifestation might present constraints on the predictive rule that was derived from this review. Such limitations notwithstanding, the decision to determine which patients should undergo neuroimaging is encouraged to be based on clinical judgments. Further analysis with higher sample sizes may be required to authenticate and validate findings.

  10. TU-H-207A-03: CT Hounsfield Unit Accuracy: Effect of Beam Hardening On Phantom and Clinical Whole-Body CT Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ai, H; Wendt, R

    2016-06-15

    Purpose: To assess the effect of beam hardening on measured CT HU values. Methods: An anthropomorphic knee phantom was scanned with the CT component of a GE Discovery 690 PET/CT scanner (120kVp, 300mAs, 40?0.625mm collimation, pitch=0.984, FOV=500mm, matrix=512?512) with four different scan setups, each of which induces different degrees of beam hardening by introducing additional attenuation media into the field of view. Homogeneous voxels representing “soft tissue” and “bone” were segmented by HU thresholding followed by a 3D morphological erosion operation which removes the non-homogenous voxels located on the interface of thresholded tissue mask. HU values of segmented “soft tissue”more » and “bone” were compared.Additionally, whole-body CT data with coverage from the skull apex to the end of toes were retrospectively retrieved from seven PET/CT exams to evaluate the effect of beam hardening in vivo. Homogeneous bone voxels were segmented with the same method previously described. Total In-Slice Attenuation (TISA) for each CT slice, defined as the summation of HU values over all voxels within a CT slice, was calculated for all slices of the seven whole-body CT datasets and evaluated against the mean HU values of homogeneous bone voxels within that slice. Results: HU values measured from the phantom showed that while “soft tissue” HU values were unaffected, added attenuation within the FOV caused noticeable decreases in the measured HU values of “bone” voxels. A linear relationship was observed between bone HU and TISA for slices of the torso and legs, but not of the skull. Conclusion: Beam hardening effect is not an issue of concern for voxels with HU in the soft tissue range, but should not be neglected for bone voxels. A linear relationship exists between bone HU and the associated TISA in non-skull CT slices, which can be exploited to develop a correction strategy.« less

  11. Enhancing 18F-FDG-PET/CT analysis in lung cancer patients. Is CT-CT image fusion helpful in predicting pleural involvement? A pilot study.

    PubMed

    Kapfhammer, A; Winkens, T; Lesser, T; Reissig, A; Steinert, M; Freesmeyer, M

    2015-01-01

    To retrospectively evaluate the feasibility and value of CT-CT image fusion to assess the shift of peripheral lung cancers with/-out chest wall infiltration, comparing computed tomography acquisitions in shallow-breathing (SB-CT) and deep-inspiration breath-hold (DIBH-CT) in patients undergoing FDG-PET/CT for lung cancer staging. Image fusion of SB-CT and DIBH-CT was performed with a multimodal workstation used for nuclear medicine fusion imaging. The distance of intrathoracic landmarks and the positional shift of tumours were measured using semi-transparent overlay of both CT series. Statistical analyses were adjusted for confounders of tumour infiltration. Cutoff levels were calculated for prediction of no-/infiltration. Lateral pleural recessus and diaphragm showed the largest respiratory excursions. Infiltrating lung cancers showed more limited respiratory shifts than non-infiltrating tumours. A large respiratory tumour-motility accurately predicted non-infiltration. However, the tumour shifts were limited and variable, limiting the accuracy of prediction. This pilot fusion study proved feasible and allowed a simple analysis of the respiratory shifts of peripheral lung tumours using CT-CT image fusion in a PET/CT setting. The calculated cutoffs were useful in predicting the exclusion of chest wall infiltration but did not accurately predict tumour infiltration. This method can provide additional qualitative information in patients with lung cancers with contact to the chest wall but unclear CT evidence of infiltration undergoing PET/CT without the need of additional investigations. Considering the small sample size investigated, further studies are necessary to verify the obtained results.

  12. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    PubMed

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  13. Cervical spine CT scan

    MedlinePlus

    ... cervical spine; Computed tomography scan of cervical spine; CT scan of cervical spine; Neck CT scan ... table that slides into the center of the CT scanner. Once you are inside the scanner, the ...

  14. Marketing cardiac CT programs.

    PubMed

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  15. Traumatic diaphragmatic injury: a review of CT signs and the difference between blunt and penetrating injury

    PubMed Central

    Panda, Ananya; Kumar, Atin; Gamanagatti, Shivanand; Patil, Aruna; Kumar, Subodh; Gupta, Amit

    2014-01-01

    PURPOSE We aimed to present the frequency of computed tomography (CT) signs of diaphragmatic rupture and the differences between blunt and penetrating trauma. MATERIALS AND METHODS The CT scans of 23 patients with surgically proven diaphragmatic tears (both blunt and penetrating) were retrospectively reviewed for previously described CT signs of diaphragmatic injuries. The overall frequency of CT signs was reported; frequency of signs in right- and left-sided injuries and blunt and penetrating trauma were separately tabulated and statistically compared. RESULTS The discontinuous diaphragm sign was the most common sign, observed in 95.7% of patients, followed by diaphragmatic thickening (69.6%). While the dependent viscera sign and collar sign were exclusively observed in blunt-trauma patients, organ herniation (P = 0.05) and dangling diaphragm (P = 0.0086) signs were observed significantly more often in blunt trauma than in penetrating trauma. Contiguous injury on either side of the diaphragm was observed more often in penetrating trauma (83.3%) than in blunt trauma (17.7%). CONCLUSION Knowledge of the mechanism of injury and familiarity with all CT signs of diaphragmatic injury are necessary to avoid a missed diagnosis because there is variability in the overall occurrence of these signs, with significant differences between blunt and penetrating trauma. PMID:24412818

  16. A generic framework to simulate realistic lung, liver and renal pathologies in CT imaging

    NASA Astrophysics Data System (ADS)

    Solomon, Justin; Samei, Ehsan

    2014-11-01

    Realistic three-dimensional (3D) mathematical models of subtle lesions are essential for many computed tomography (CT) studies focused on performance evaluation and optimization. In this paper, we develop a generic mathematical framework that describes the 3D size, shape, contrast, and contrast-profile characteristics of a lesion, as well as a method to create lesion models based on CT data of real lesions. Further, we implemented a technique to insert the lesion models into CT images in order to create hybrid CT datasets. This framework was used to create a library of realistic lesion models and corresponding hybrid CT images. The goodness of fit of the models was assessed using the coefficient of determination (R2) and the visual appearance of the hybrid images was assessed with an observer study using images of both real and simulated lesions and receiver operator characteristic (ROC) analysis. The average R2 of the lesion models was 0.80, implying that the models provide a good fit to real lesion data. The area under the ROC curve was 0.55, implying that the observers could not readily distinguish between real and simulated lesions. Therefore, we conclude that the lesion-modeling framework presented in this paper can be used to create realistic lesion models and hybrid CT images. These models could be instrumental in performance evaluation and optimization of novel CT systems.

  17. Association of interleukin-1 beta (-511C/T) polymorphisms with osteoporosis in postmenopausal women.

    PubMed

    Chao, Tai-Hung; Yu, Hsing-Ning; Huang, Chi-Chuan; Liu, Wen-Shen; Tsai, Ya-Wen; Wu, Wen-Tung

    2010-01-01

    Osteoporosis is a common disease of the elderly, in which genetic and clinical factors contribute to the disease phenotype. Since the production of interleukin-1 (IL-1) has been implicated in the bone mass and skeletal disorders, we investigated whether IL-1 system gene polymorphisms are associated with the pathogenesis of osteoporosis in postmenopausal Taiwanese women. Osteoporosis is diagnosed by dual-energy x-ray absorptiometry, which measures bone mineral density (BMD) at multiple skeletal sites. We studied the IL-1α (-889C/T), IL-1β (-511C/T) and the 86 base pair variable number tandem repeat (VNTR) in intron 2 of the IL-1 receptor antagonist (IL-1ra) gene in 117 postmenopausal women with osteoporosis and 135 control subjects without a history of symptomatic osteoporosis. These gene polymorphisms were analyzed by polymerase chain reaction and restriction fragment length polymerase. Blood sugar and other risk factors were also determined. The frequencies of IL-1β (-511C/T) genotypes (P=.022, odds ratio=1.972) and alleles (P=.02, odds ratio=2.909) showed a statistically significant difference between the two groups. However, we did not find any statistically significant difference in IL-1β and IL-1ra polymorphisms (P>.05). We also observed a positive relationship between osteoporosis and cholesterol and a weak inverse relationship between blood sugar and osteoporosis in postmenopausal women. These experimental results suggest that the pathogenesis of osteoporosis is associated with IL-1β (-511C/T) polymorphism in postmenopausal women. This polymorphism is an independent risk factor for osteoporosis.

  18. Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner

    NASA Astrophysics Data System (ADS)

    Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.

    2006-03-01

    We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.

  19. Phylogenetic ctDNA analysis depicts early stage lung cancer evolution

    PubMed Central

    Abbosh, Christopher; Birkbak, Nicolai J.; Wilson, Gareth A.; Jamal-Hanjani, Mariam; Constantin, Tudor; Salari, Raheleh; Le Quesne, John; Moore, David A; Veeriah, Selvaraju; Rosenthal, Rachel; Marafioti, Teresa; Kirkizlar, Eser; Watkins, Thomas B K; McGranahan, Nicholas; Ward, Sophia; Martinson, Luke; Riley, Joan; Fraioli, Francesco; Al Bakir, Maise; Grönroos, Eva; Zambrana, Francisco; Endozo, Raymondo; Bi, Wenya Linda; Fennessy, Fiona M.; Sponer, Nicole; Johnson, Diana; Laycock, Joanne; Shafi, Seema; Czyzewska-Khan, Justyna; Rowan, Andrew; Chambers, Tim; Matthews, Nik; Turajlic, Samra; Hiley, Crispin; Lee, Siow Ming; Forster, Martin D.; Ahmad, Tanya; Falzon, Mary; Borg, Elaine; Lawrence, David; Hayward, Martin; Kolvekar, Shyam; Panagiotopoulos, Nikolaos; Janes, Sam M; Thakrar, Ricky; Ahmed, Asia; Blackhall, Fiona; Summers, Yvonne; Hafez, Dina; Naik, Ashwini; Ganguly, Apratim; Kareht, Stephanie; Shah, Rajesh; Joseph, Leena; Quinn, Anne Marie; Crosbie, Phil; Naidu, Babu; Middleton, Gary; Langman, Gerald; Trotter, Simon; Nicolson, Marianne; Remmen, Hardy; Kerr, Keith; Chetty, Mahendran; Gomersall, Lesley; Fennell, Dean; Nakas, Apostolos; Rathinam, Sridhar; Anand, Girija; Khan, Sajid; Russell, Peter; Ezhil, Veni; Ismail, Babikir; Irvin-sellers, Melanie; Prakash, Vineet; Lester, Jason; Kornaszewska, Malgorzata; Attanoos, Richard; Adams, Haydn; Davies, Helen; Oukrif, Dahmane; Akarca, Ayse U; Hartley, John A; Lowe, Helen L; Lock, Sara; Iles, Natasha; Bell, Harriet; Ngai, Yenting; Elgar, Greg; Szallasi, Zoltan; Schwarz, Roland F; Herrero, Javier; Stewart, Aengus; Quezada, Sergio A; Peggs, Karl S.; Van Loo, Peter; Dive, Caroline; Lin, Jimmy; Rabinowitz, Matthew; Aerts, Hugo JWL; Hackshaw, Allan; Shaw, Jacqui A; Zimmermann, Bernhard G.; Swanton, Charles

    2017-01-01

    Summary The early detection of relapse following primary surgery for non-small cell lung cancer and the characterization of emerging subclones seeding metastatic sites might offer new therapeutic approaches to limit tumor recurrence. The potential to non-invasively track tumor evolutionary dynamics in ctDNA of early-stage lung cancer is not established. Here we conduct a tumour-specific phylogenetic approach to ctDNA profiling in the first 100 TRACERx (TRAcking non-small cell lung Cancer Evolution through therapy (Rx)) study participants, including one patient co-recruited to the PEACE (Posthumous Evaluation of Advanced Cancer Environment) post-mortem study. We identify independent predictors of ctDNA release and perform tumor volume limit of detection analyses. Through blinded profiling of post-operative plasma, we observe evidence of adjuvant chemotherapy resistance and identify patients destined to experience recurrence of their lung cancer. Finally, we show that phylogenetic ctDNA profiling tracks the subclonal nature of lung cancer relapse and metastases, providing a new approach for ctDNA driven therapeutic studies PMID:28445469

  20. Phylogenetic ctDNA analysis depicts early-stage lung cancer evolution.

    PubMed

    Abbosh, Christopher; Birkbak, Nicolai J; Wilson, Gareth A; Jamal-Hanjani, Mariam; Constantin, Tudor; Salari, Raheleh; Le Quesne, John; Moore, David A; Veeriah, Selvaraju; Rosenthal, Rachel; Marafioti, Teresa; Kirkizlar, Eser; Watkins, Thomas B K; McGranahan, Nicholas; Ward, Sophia; Martinson, Luke; Riley, Joan; Fraioli, Francesco; Al Bakir, Maise; Grönroos, Eva; Zambrana, Francisco; Endozo, Raymondo; Bi, Wenya Linda; Fennessy, Fiona M; Sponer, Nicole; Johnson, Diana; Laycock, Joanne; Shafi, Seema; Czyzewska-Khan, Justyna; Rowan, Andrew; Chambers, Tim; Matthews, Nik; Turajlic, Samra; Hiley, Crispin; Lee, Siow Ming; Forster, Martin D; Ahmad, Tanya; Falzon, Mary; Borg, Elaine; Lawrence, David; Hayward, Martin; Kolvekar, Shyam; Panagiotopoulos, Nikolaos; Janes, Sam M; Thakrar, Ricky; Ahmed, Asia; Blackhall, Fiona; Summers, Yvonne; Hafez, Dina; Naik, Ashwini; Ganguly, Apratim; Kareht, Stephanie; Shah, Rajesh; Joseph, Leena; Marie Quinn, Anne; Crosbie, Phil A; Naidu, Babu; Middleton, Gary; Langman, Gerald; Trotter, Simon; Nicolson, Marianne; Remmen, Hardy; Kerr, Keith; Chetty, Mahendran; Gomersall, Lesley; Fennell, Dean A; Nakas, Apostolos; Rathinam, Sridhar; Anand, Girija; Khan, Sajid; Russell, Peter; Ezhil, Veni; Ismail, Babikir; Irvin-Sellers, Melanie; Prakash, Vineet; Lester, Jason F; Kornaszewska, Malgorzata; Attanoos, Richard; Adams, Haydn; Davies, Helen; Oukrif, Dahmane; Akarca, Ayse U; Hartley, John A; Lowe, Helen L; Lock, Sara; Iles, Natasha; Bell, Harriet; Ngai, Yenting; Elgar, Greg; Szallasi, Zoltan; Schwarz, Roland F; Herrero, Javier; Stewart, Aengus; Quezada, Sergio A; Peggs, Karl S; Van Loo, Peter; Dive, Caroline; Lin, C Jimmy; Rabinowitz, Matthew; Aerts, Hugo J W L; Hackshaw, Allan; Shaw, Jacqui A; Zimmermann, Bernhard G; Swanton, Charles

    2017-04-26

    The early detection of relapse following primary surgery for non-small-cell lung cancer and the characterization of emerging subclones, which seed metastatic sites, might offer new therapeutic approaches for limiting tumour recurrence. The ability to track the evolutionary dynamics of early-stage lung cancer non-invasively in circulating tumour DNA (ctDNA) has not yet been demonstrated. Here we use a tumour-specific phylogenetic approach to profile the ctDNA of the first 100 TRACERx (Tracking Non-Small-Cell Lung Cancer Evolution Through Therapy (Rx)) study participants, including one patient who was also recruited to the PEACE (Posthumous Evaluation of Advanced Cancer Environment) post-mortem study. We identify independent predictors of ctDNA release and analyse the tumour-volume detection limit. Through blinded profiling of postoperative plasma, we observe evidence of adjuvant chemotherapy resistance and identify patients who are very likely to experience recurrence of their lung cancer. Finally, we show that phylogenetic ctDNA profiling tracks the subclonal nature of lung cancer relapse and metastasis, providing a new approach for ctDNA-driven therapeutic studies.

  1. Indeterminate lung nodules in cancer patients: pretest probability of malignancy and the role of 18F-FDG PET/CT.

    PubMed

    Evangelista, Laura; Panunzio, Annalori; Polverosi, Roberta; Pomerri, Fabio; Rubello, Domenico

    2014-03-01

    The purpose of this study was to determine likelihood of malignancy for indeterminate lung nodules identified on CT comparing two standardized models with (18)F-FDG PET/CT. Fifty-nine cancer patients with indeterminate lung nodules (solid tumors; diameter, ≥5 mm) on CT had FDG PET/CT for lesion characterization. Mayo Clinic and Veterans Affairs Cooperative Study models of likelihood of malignancy were applied to solitary pulmonary nodules. High probability of malignancy was assigned a priori for multiple nodules. Low (<5%), intermediate (5-60%), and high (>60%) pretest malignancy probabilities were analyzed separately. Patients were reclassified with PET/CT. Histopathology or 2-year imaging follow-up established diagnosis. Outcome-based reclassification differences were defined as net reclassification improvement. A null hypothesis of asymptotic test was applied. Thirty-one patients had histology-proven malignancy. PET/CT was true-positive in 24 and true-negative in 25 cases. Negative predictive value was 78% and positive predictive value was 89%. On the basis of the Mayo Clinic model (n=31), 18 patients had low, 12 had intermediate, and one had high pretest likelihood; on the basis of the Veterans Affairs model (n=26), 5 patients had low, 20 had intermediate, and one had high pretest likelihood. Because of multiple lung nodules, 28 patients were classified as having high malignancy risk. PET/CT showed 32 negative and 27 positive scans. Net reclassification improvements respectively were 0.95 and 1.6 for Mayo Clinic and Veterans Affairs models (both p<0.0001). Fourteen of 31 (45.2%) and 12 of 26 (46.2%) patients with low and intermediate pretest likelihood, respectively, had positive findings on PET/CT for the Mayo Clinic and Veterans Affairs models, respectively. Of 15 patients with high pretest likelihood and negative findings on PET/CT, 13 (86.7%) did not have lung malignancy. PET/CT improves stratification of cancer patients with indeterminate pulmonary

  2. Computed Tomographic Findings and Mortality in Patients With Pneumomediastinum From Blunt Trauma.

    PubMed

    Lee, Wayne S; Chong, Vincent E; Victorino, Gregory P

    2015-08-01

    The care of most patients with pneumomediastinum (PNM) due to trauma can be managed conservatively; however, owing to aerodigestive tract injury and other associated injuries, there is a subset of patients with PNM who are at higher risk of mortality but can be difficult to identify. To characterize computed tomographic (CT) findings associated with mortality in patients with PNM due to blunt trauma. A retrospective review of medical records from January 1, 2002, to December 31, 2011, was conducted at a university-based urban trauma center. The patients evaluated were those injured by blunt trauma and found to have PNM on initial chest CT scanning. Data analysis was performed July 2, 2013, to June 18, 2014. In-hospital mortality. During the study period, 3327 patients with blunt trauma underwent chest CT. Of these, 72 patients (2.2%) had PNM. Patients with PNM had higher Injury Severity Scores (P < .001) and chest Abbreviated Injury Scale scores (P < .001) compared with those without PNM. Pneumomediastinum was associated with higher mortality (9 [12.5%] vs 118 [3.6%] patients; P < .001) and longer mean (SD) hospital stays (11.3 [14.6] vs 5.1 [8.8] days; P < .001), intensive care unit stays (5.4 [10.2] vs 1.8 [5.7] days; P < .001), and ventilator days (1.7 [4.2] vs 0.6 [4.0] days; P < .03). We evaluated several chest CT findings that may have predictive value. Pneumomediastinum size was not associated with in-hospital mortality (P = .22). However, location of air in the posterior mediastinum was associated with increased mortality of 25% (7 of 28 patients; P = .007). Air in all mediastinal compartments was also associated with increased mortality of 40.0% (4 of 10 patients; P = .01). Presence of hemothorax along with PNM was associated with mortality of 22.2% (8 of 36 patients; P = .01). Pneumomediastinum is uncommon in patients with injury from blunt trauma; however, CT findings of posterior PNM, air in all mediastinal

  3. Outcome of Blunt Abdominal Traumas with Stable Hemodynamic and Positive FAST Findings.

    PubMed

    Behboodi, Firooz; Mohtasham-Amiri, Zahra; Masjedi, Navid; Shojaie, Reza; Sadri, Peyman

    2016-01-01

    Focused assessment with sonography for trauma (FAST) is a highly effective first screening tool for initial classification of abdominal trauma patients. The present study was designed to evaluate the outcome of patients with blunt abdominal trauma and positive FAST findings. The present prospective cross-sectional study was done on patients over 7 years old with normal abdominal examination, positive FAST findings, and available abdominopelvic computed tomography (CT) scan findings. The frequency of need for laparotomy as well as its probable risk factors were calculated. 180 patients were enrolled (mean age: 28.0 ± 11.5 years; 76.7% male). FAST findings were confirmed by abdominopelvic CT scan in only 124 (68.9%) cases. Finally, 12 (6.6%) patients needed laparotomy. Mean age of those in need of laparotomy was significantly higher than others (36.75 ± 11.37 versus 27.34 ± 11.37, p = 0.006). Higher grading of spleen (p = 0.001) and hepatic (p = 0.038) ruptures increased the probability of need for laparotomy. 68.9% of the positive FAST findings in patients with blunt abdominal trauma and stable hemodynamics was confirmed by abdominopelvic CT scan and only 6.6% needed laparotomy. Simultaneous presence of free fluid and air in the abdominal area, old age, and higher grading o solid organ injuries were factors that had a significant correlation with need for laparotomy.

  4. Genome-wide profiles of CtBP link metabolism with genome stability and epithelial reprogramming in breast cancer.

    PubMed

    Di, Li-Jun; Byun, Jung S; Wong, Madeline M; Wakano, Clay; Taylor, Tara; Bilke, Sven; Baek, Songjoon; Hunter, Kent; Yang, Howard; Lee, Maxwell; Zvosec, Cecilia; Khramtsova, Galina; Cheng, Fan; Perou, Charles M; Miller, C Ryan; Raab, Rachel; Olopade, Olufunmilayo I; Gardner, Kevin

    2013-01-01

    The C-terminal binding protein (CtBP) is a NADH-dependent transcriptional repressor that links carbohydrate metabolism to epigenetic regulation by recruiting diverse histone-modifying complexes to chromatin. Here global profiling of CtBP in breast cancer cells reveals that it drives epithelial-to-mesenchymal transition, stem cell pathways and genome instability. CtBP expression induces mesenchymal and stem cell-like features, whereas CtBP depletion or caloric restriction reverses gene repression and increases DNA repair. Multiple members of the CtBP-targeted gene network are selectively downregulated in aggressive breast cancer subtypes. Differential expression of CtBP-targeted genes predicts poor clinical outcome in breast cancer patients, and elevated levels of CtBP in patient tumours predict shorter median survival. Finally, both CtBP promoter targeting and gene repression can be reversed by small molecule inhibition. These findings define broad roles for CtBP in breast cancer biology and suggest novel chromatin-based strategies for pharmacologic and metabolic intervention in cancer.

  5. FDG-PET/CT imaging for tumor staging and definition of tumor volumes in radiation treatment planning in non-small cell lung cancer.

    PubMed

    Zheng, Yuanda; Sun, Xiaojiang; Wang, Jian; Zhang, Lingnan; DI, Xiaoyun; Xu, Yaping

    2014-04-01

    18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) has the potential to improve the staging and radiation treatment (RT) planning of various tumor sites. However, from a clinical standpoint, questions remain with regard to what extent PET/CT changes the target volume and whether PET/CT reduces interobserver variability in target volume delineation. The present study analyzed the use of FDG-PET/CT images for staging and evaluated the impact of FDG-PET/CT on the radiotherapy volume delineation compared with CT in patients with non-small cell lung cancer (NSCLC) who were candidates for radiotherapy. Intraobserver variation in delineating tumor volumes was also observed. In total, 23 patients with stage I-III NSCLC were enrolled and treated with fractionated RT-based therapy with or without chemotherapy. FDG-PET/CT scans were acquired within two weeks prior to RT. PET and CT data sets were sent to the treatment planning system, Pinnacle, through compact discs. The CT and PET images were subsequently fused by means of a dedicated RT planning system. Gross tumor volume (GTV) was contoured by four radiation oncologists on CT (GTV-CT) and PET/CT images (GTV-PET/CT). The resulting volumes were analyzed and compared. For the first phase, two radiation oncologists outlined the contours together, achieving a final consensus. Based on PET/CT, changes in tumor-node-metastasis categories occurred in 8/23 cases (35%). Radiation targeting with fused FDG-PET and CT images resulted in alterations in radiation therapy planning in 12/20 patients (60%) in comparison with CT targeting. The most prominent changes in GTV were observed in cases with atelectasis. For the second phase, the variation in delineating tumor volumes was assessed by four observers. The mean ratio of largest to smallest CT-based GTV was 2.31 (range, 1.01-5.96). The addition of the PET results reduced the mean ratio to 1.46 (range, 1.02-2.27). PET/CT fusion images may have a

  6. 68Ga-DOTATATE PET/CT interobserver agreement for neuroendocrine tumor assessments: results from a prospective study on 50 patients

    PubMed Central

    Fendler, Wolfgang Peter; Barrio, Martin; Spick, Claudio; Allen-Auerbach, Martin; Ambrosini, Valentina; Benz, Matthias; Bluemel, Christina; Grewal, Ravinder Kaur; Lapa, Constantin; Miederer, Matthias; Nicolas, Guillaume; Schuster, Tibor; Czernin, Johannes; Herrmann, Ken

    2016-01-01

    We evaluated the observer agreement for 68Ga-DOTATATE PET/CT study interpretations in patients with neuroendocrine tumors (NET). Methods 68Ga-DOTATATE PET/CT was performed in 50 patients with known or suspected NET of the small bowel (n = 19), pancreas (n = 14), lung (n = 4) or other location (n = 13). Images were reviewed by seven observers who used a standardized approach for image interpretation. Observers were classified as having low (<500 scans or <5 years experience with 68Ga-DOTATATE PET/CT; n = 4) or high level of experience (≥500 scans and ≥5 years experience with 68Ga-DOTATATE PET/CT; n = 3). Interpretation by the primary nuclear medicine physician un-blinded to all clinical and imaging data served as reference standard. Interobserver agreement was determined by Cohen's κ and intraclass correlation coefficient (ICC) with corresponding 95% confidence interval (CI). Results Interobserver agreement was substantial and the median number of false findings (FF) was low for the overall scan result; i.e. positive versus negative study (κ = 0.80, 95%CI 0.74–0.86; FF = 3), organ involvement (κ = 0.70, 95%CI 0.64–0.76; FF = 5), and lymph node involvement (κ = 0.71, 95%CI 0.65–0.78; FF = 6). The interobserver agreement was substantial to almost-perfect and the average absolute difference (Δ) to the reference reader was low for number of organ and lymph node metastases (ICC = 0.84, 95%CI 0.77–0.89, Δ = 0.45 and ICC = 0.77, 95%CI 0.69–0.84, Δ = 0.45), tumor SUVmax (ICC = 0.99, 95%CI 0.97–0.99; Δ = 0.44) and reference SUV (SUVmean spleen: ICC = 0.81, Δ = 1.10; SUVmax liver ICC = 0.79, Δ = 0.62). Interpretations of the appropriateness for peptide-receptor radionuclide therapy (PRRT) varied more significantly among observers (κ = 0.64, 95%CI 0.57–0.70) and a higher frequency of false positive recommendations for PRRT occurred in observers with low versus high levels of experience (range, 7–12 versus 4–8). Conclusion The interpretation of

  7. Computed tomographic findings in dogs and cats with temporomandibular joint disorders: 58 cases (2006–2011)

    PubMed Central

    Arzi, Boaz; Cissell, Derek D.; Verstraete, Frank J. M.; Kass, Philip H.; DuRaine, Grayson D.; Athanasiou, Kyriacos A.

    2013-01-01

    Objective To describe CT findings in dogs and cats with temporomandibular joint (TMJ) disorders. Design Retrospective case-series. Animals 41 dogs and 17 cats. Procedures Medical records and CT images of the skull were reviewed for dogs and cats that were examined at a dentistry and oral surgery specialty practice between 2006 and 2011. Results Of 142 dogs and 42 cats evaluated, 41 dogs and 17 cats had CT findings consistent with a TMJ disorder. In dogs, the most common TMJ disorder was osteoarthritis; however, in most cases, there were other TMJ disorders present in addition to osteoarthritis. Osteoarthritis was more frequently identified at the medial aspect rather than the lateral aspect of the TMJ, whereas the frequency of osteoarthritic involvement of the dorsal and ventral compartments did not differ significantly. In cats, fractures were the most common TMJ disorder, followed by osteoarthritis. Clinical signs were observed in all dogs and cats with TMJ fractures, dysplasia, ankylosis, luxation, and tumors; however, only 4 of 15 dogs and 2 of 4 cats with osteoarthritis alone had clinical signs. Conclusions and Clinical Relevance Results indicated that TMJ disorders are frequently present in combination. Osteoarthritis was the most common TMJ disorder in dogs and the second most common TMJ disorder in cats. Computed tomography should be considered as a tool for the diagnosis of TMJ disorders in dogs and cats with suspected orofacial disorders and pain. PMID:23234284

  8. Importance of 18F-FDG PET/CT to select patients with nonresectable colorectal liver metastases for liver transplantation.

    PubMed

    Grut, Harald; Revheim, Mona-Elisabeth; Line, Pål-Dag; Dueland, Svein

    2018-04-20

    The aim of this study was to evaluate fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT for the selection of patients with nonresectable colorectal liver metastases (NCLM) for liver transplantation (LT). In the secondary cancer study, we reported an improved 5-year overall survival in patients treated with LT for NCLM (56%) compared with chemotherapy (9%). However, many patients were rejected for LT owing to the detection of extrahepatic disease at preoperative imaging. F-FDG PET/CT and contrast-enhanced computed tomography (ceCT) examinations before tentative LT for NCLM were assessed, and findings contraindicating LT were registered. Maximum, mean and peak standardized uptake values; tumor-to-background ratio; metabolic tumor volume; and total lesion glycolysis were measured and calculated for all liver metastases. Overall survival was calculated by the Kaplan-Meier method. Thirty-two patients excluded by F-FDG PET/CT and/or ceCT before tentative LT for NCLM were identified. F-FDG PET/CT from 20 of the 32 excluded patients revealed extrahepatic disease. Eight of the other 12 patients had a negative F-FDG PET/CT finding but were excluded by ceCT. Ten patients were excluded by F-FDG PET/CT only. Four patients were excluded owing to detected malignancy from frozen sections at the start of the intended transplant operation. Tumor-to-background ratio of the liver metastases was significantly higher in patients where F-FDG PET/CT detected extrahepatic disease (P=0.03). The median (range) survival after exclusion was 16 (0-52) months. The ability of F-FDG PET/CT to detect extrahepatic disease before LT for NCLM is vital to establish LT as a treatment option.

  9. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun

    2008-12-15

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACTmore » from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma ({gamma}) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass

  10. CRYPTOSPORIDIUM LOG-INACTIVATION WITH OZONE USING EFFLUENT CT 10, GEOMETRIC MEAN CT 10 EXTENDED INTEGRATED CT 10 AND EXTENDED-CSTR CALCULATIONS

    EPA Science Inventory

    The draft Long Term 2 Enhanced Surface Water Treatment Rule ("LT2ESWTR") contains Cryptosporidium log-inactivation CT tables. Depending on the water temperature, the Cryptosporidium CT values that are listed are 15 to 25 times greater than CT values fo...

  11. Lateral topography for reducing effective dose in low-dose chest CT.

    PubMed

    Bang, Dong-Ho; Lim, Daekeon; Hwang, Wi-Sub; Park, Seong-Hoon; Jeong, Ok-man; Kang, Kyung Wook; Kang, Hohyung

    2013-06-01

    The purposes of this study were to assess radiation exposure during low-dose chest CT by using lateral topography and to compare the lateral topographic findings with findings obtained with anteroposterior topography alone and anteroposterior and lateral topography combined. From November 2011 to February 2012, 210 male subjects were enrolled in the study. Age, weight, and height of the men were recorded. All subjects were placed into one of three subgroups based on the type of topographic image obtained: anteroposterior topography, lateral topography, and both anteroposterior and lateral topography. Imaging was performed with a 128-MDCT scanner. CT, except for topography, was the same for all subjects. A radiologist analyzed each image, recorded scan length, checked for any insufficiencies in the FOV, and calculated the effective radiation dose. One-way analysis of variance and multiple comparisons were used to compare the effective radiation exposure and scan length between groups. The mean scan length in the anteroposterior topography group was significantly greater than that of the lateral topography group and the combined anteroposterior and lateral topography group (p < 0.001). The mean effective radiation dose for the lateral topography group (0.735 ± 0.033 mSv) was significantly lower than that for the anteroposterior topography group (0.763 ± 0.038 mSv) and the combined anteroposterior and lateral topography group (0.773 ± 0.038) (p < 0.001). Lateral topographic low-dose CT was associated with a lower effective radiation dose and scan length than either anteroposterior topographic low-dose chest CT or low-dose chest CT with both anteroposterior and lateral topograms.

  12. Angioinvasive pulmonary aspergillosis after allogeneic bone marrow transplantation: clinical and high-resolution computed tomography findings in 12 cases.

    PubMed

    Gasparetto, Emerson L; Souza, Carolina A; Tazoniero, Priscilla; Davaus, Taisa; Escuissato, Dante L; Marchiori, Edson

    2007-02-01

    The aim of this study was to present the clinical and high-resolution CT scan findings of angioinvasive pulmonary aspergillosis (APA) in 12 patients who underwent allogeneic bone marrow transplantation (BMT). The CT scans were reviewed by three chest radiologists who assessed the pattern and distribution of findings by consent. There were 7 (58%) female and 5 (42%) male patients, with aging between 5 and 50 years (average of 26 years). All patients were submitted to BMT for the treatment of hematological conditions. The diagnosis of APA was defined between 5 and 373 days after BMT, with average of 111 days. Three cases (25%) were diagnosed in the neutropenic phase after the BMT, five (42%) in the early phase and four patients in the late phase post-BMT. Regarding high-resolution CT (HRCT) scan findings, nodules were found in 75% of the cases (9/12), most of the cases with more than 10 lesions (7/9) and of centrilobular localization (6/9). Consolidations were identified in seven patients (58%), being single in six, and commonly presenting ill defined borders (n=3) and subsegmental localization (n=5). Ground glass attenuation was found in six patients (50%). The halo sign was observed in nine cases (75%). Cavitations were seen in two air-space consolidations and one large nodule (2.5 cm). Patients submitted to BMT presenting respiratory symptoms and nodules or consolidations with halo sign at HRCT scan need to have the diagnosis of angioinvasive pulmonary aspergillosis included in all the post BMT phases.

  13. [Study on the aggregation behavior of cationic porphyrins and their interaction with ctDNA].

    PubMed

    Ma, Hong-Min; Chen, Xin; Sun, Shu-Ting; Zhang, Li-Na; Wu, Dan; Zhu, Pei-Hua; Li, Yan; Du, Bin; Wei, Qin

    2009-02-01

    Interest in the interaction between cationic porphyrins, particularly derivatives of meso-tetra(N-methylpyridinium-4-yl) porphyrin(TMPyP), and DNA abounds because they are versatile DNA-binding agents that could find application in photodynamic therapy, cancer detection, artificial nucleases, virus inhibition and so on. The interaction of two water-soluble cationic porphyrins, meso-tetrakis(4-N, N, N-trimethylanilinium) porphyrin (TMAP) and 5-phenyl-10,15,20-tris[4-(N-methyl) pyridinium]porphyrin (TriMPyP), with calf thymus DNA (ctDNA) was studied by UV-Vis absorption spectroscopy, fluorescence spectroscopy and resonance light scattering technique. TriMPyP forms aggregate in water due to the molecular asymmetry while TMAP exists as monomers. At lower concentrations of ctDNA (R > 1, R = c(TMAP)/c(DNA) base pair), the interaction of TMAP with DNA leads to significant hypochromicity and bathochromic shift of absorption spectra. And the fluorescence of TMAP was quenched while it showed enhanced resonance light scattering signals. But the extent of enhancement of resonance light scattering signals is very small, so the aggregate of TMAP is not very high. These observations indicate the self-stacking of TMAP along the DNA surface. At higher concentrations of ctDNA (R < 1), TMAP association with DNA is via outside binding which is accompanied with hyperchromic effect and fluorescence enhancement while the resonance light scattering signals is reduced. DNA addition decreases the fluorescence intensity of TriMPyP and it shifts the peak to the higher wavelengths (red shift). The interaction with DNA promotes the aggregation of TriMPyP and no simple outside binding is observed even at higher concentrations of ctDNA. The steric effect of molecular distortion constrains the intercalation or further binding to DNA. The effect of ionic strength on the interaction was investigated at two DNA concentrations, 1.2 and 24.0 micromol x L(-1), for TMAP. The Interactions of both

  14. Does CT Angiography Matter for Patients with Cervical Spine Injuries?

    PubMed

    Hagedorn, John C; Emery, Sanford E; France, John C; Daffner, Scott D

    2014-06-04

    $3925, radiation exposure was approximately 4000 mGy/cm, and contrast-medium load was approximately 100 mL. Positive CT angiography of the head and neck rarely altered surgical treatment of cervical spine injuries. This study supports the findings in the literature that C1-C3 spine injuries have an increased association with vertebral artery injury. CT angiography of the head and neck ordered off protocol had a low likelihood of being positive. Strict adherence to protocols for CT angiography of the head and neck can reduce costs and decrease unnecessary exposure to radiation and contrast medium. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  15. Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer.

    PubMed

    Kornerup, Josefine S; Brodin, Patrik; Birk Christensen, Charlotte; Björk-Eriksson, Thomas; Kiil-Berthelsen, Anne; Borgwardt, Lise; Munck Af Rosenschöld, Per

    2015-04-01

    PET/CT may be more helpful than CT alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. To estimate the risk of cancer induction and mortality attributable to the [F-18]2-fluoro-2-deoxyglucose (FDG) PET and CT scans used for radiation therapy planning in children with cancer, and compare to the risks attributable to the cancer treatment. Organ doses and effective doses were estimated for 40 children (2-18 years old) who had been scanned using PET/CT as part of radiation therapy planning. The risk of inducing secondary cancer was estimated using the models in BEIR VII. The prognosis of an induced cancer was taken into account and the reduction in life expectancy, in terms of life years lost, was estimated for the diagnostics and compared to the life years lost attributable to the therapy. Multivariate linear regression was performed to find predictors for a high contribution to life years lost from the radiation therapy planning diagnostics. The mean contribution from PET to the effective dose from one PET/CT scan was 24% (range: 7-64%). The average proportion of life years lost attributable to the nuclear medicine dose component from one PET/CT scan was 15% (range: 3-41%). The ratio of life years lost from the radiation therapy planning PET/CT scans and that of the cancer treatment was on average 0.02 (range: 0.01-0.09). Female gender was associated with increased life years lost from the scans (P < 0.001). Using FDG-PET/CT instead of CT only when defining the target volumes for radiation therapy of children with cancer does not notably increase the number of life years lost attributable to diagnostic examinations.

  16. CT-based radiomics signature for differentiating Borrmann type IV gastric cancer from primary gastric lymphoma.

    PubMed

    Ma, Zelan; Fang, Mengjie; Huang, Yanqi; He, Lan; Chen, Xin; Liang, Cuishan; Huang, Xiaomei; Cheng, Zixuan; Dong, Di; Liang, Changhong; Xie, Jiajun; Tian, Jie; Liu, Zaiyi

    2017-06-01

    To evaluate the value of CT-based radiomics signature for differentiating Borrmann type IV gastric cancer (GC) from primary gastric lymphoma (PGL). 40 patients with Borrmann type IV GC and 30 patients with PGL were retrospectively recruited. 485 radiomics features were extracted and selected from the portal venous CT images to build a radiomics signature. Subjective CT findings, including gastric wall peristalsis, perigastric fat infiltration, lymphadenopathy below the renal hila and enhancement pattern, were assessed to construct a subjective findings model. The radiomics signature, subjective CT findings, age and gender were integrated into a combined model by multivariate analysis. The diagnostic performance of these three models was assessed with receiver operating characteristics curves (ROC) and were compared using DeLong test. The subjective findings model, the radiomics signature and the combined model showed a diagnostic accuracy of 81.43% (AUC [area under the curve], 0.806; 95% CI [confidence interval]: 0.696-0.917; sensitivity, 63.33%; specificity, 95.00%), 84.29% (AUC, 0.886 [95% CI: 0.809-0.963]; sensitivity, 86.67%; specificity, 82.50%), 87.14% (AUC, 0.903 [95%CI: 0.831-0.975]; sensitivity, 70.00%; specificity, 100%), respectively. There were no significant differences in AUC among these three models (P=0.051-0.422). Radiomics analysis has the potential to accurately differentiate Borrmann type IV GC from PGL. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Association of FAS-670A/G and FASL-844C/T polymorphisms with idiopathic azoospermia in Western Iran.

    PubMed

    Asgari, Rezvan; Mansouri, Kamran; Bakhtiari, Mitra; Bidmeshkipour, Ali; Yari, Kheirollah; Shaveisi-Zadeh, Farhad; Vaisi-Raygani, Asad

    2017-11-01

    The FAS/FASL interaction plays a central role in up-regulation of apoptosis in testis. Studies indicated that the FAS-670A/G and FASL-844C/T polymorphisms are associated with the risk of idiopathic azoospermia in different ethnic groups. Therefore, the current study aims to investigate the association between FAS-670A/G and FASL-844C/T polymorphisms with male idiopathic infertility in Western Iran. The analysis of FAS-670A/G and FASL-844C/T polymorphisms were carried out using the PCR-RFLP approach, on 102 infertile men and 110 normal fertile men as control group. The results suggested that there were no significant difference in genotypic frequencies of FAS-670A/G polymorphism between infertile and control groups. On the other hand, significant result was observed for the frequency of FASL-844C/T polymorphism in infertile men in comparison to control group (P=0.02). Indeed, men with FASL-844TT and CT genotypes had an increased risk of idiopathic azoospermia in comparison to those with CC genotype (OR=2.02, 95% CI [1.05-3.88, P=0.03] and OR=1.44, 95% CI [0.46-4.49, P=0.53]), respectively. Our findings speculate that the FASL-844C/T polymorphism is associated with the risk of male infertility and this variation can be considered as a genetic risk factor for idiopathic azoospermia among Western Iranian men population. Summing up, these data indicated that the genetic variations in FAS/FASL system have a critical role in spermatogenesis defects and subsequent male infertility. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    PubMed

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  19. Automated Critical Test Findings Identification and Online Notification System Using Artificial Intelligence in Imaging.

    PubMed

    Prevedello, Luciano M; Erdal, Barbaros S; Ryu, John L; Little, Kevin J; Demirer, Mutlu; Qian, Songyue; White, Richard D

    2017-12-01

    Purpose To evaluate the performance of an artificial intelligence (AI) tool using a deep learning algorithm for detecting hemorrhage, mass effect, or hydrocephalus (HMH) at non-contrast material-enhanced head computed tomographic (CT) examinations and to determine algorithm performance for detection of suspected acute infarct (SAI). Materials and Methods This HIPAA-compliant retrospective study was completed after institutional review board approval. A training and validation dataset of noncontrast-enhanced head CT examinations that comprised 100 examinations of HMH, 22 of SAI, and 124 of noncritical findings was obtained resulting in 2583 representative images. Examinations were processed by using a convolutional neural network (deep learning) using two different window and level configurations (brain window and stroke window). AI algorithm performance was tested on a separate dataset containing 50 examinations with HMH findings, 15 with SAI findings, and 35 with noncritical findings. Results Final algorithm performance for HMH showed 90% (45 of 50) sensitivity (95% confidence interval [CI]: 78%, 97%) and 85% (68 of 80) specificity (95% CI: 76%, 92%), with area under the receiver operating characteristic curve (AUC) of 0.91 with the brain window. For SAI, the best performance was achieved with the stroke window showing 62% (13 of 21) sensitivity (95% CI: 38%, 82%) and 96% (27 of 28) specificity (95% CI: 82%, 100%), with AUC of 0.81. Conclusion AI using deep learning demonstrates promise for detecting critical findings at noncontrast-enhanced head CT. A dedicated algorithm was required to detect SAI. Detection of SAI showed lower sensitivity in comparison to detection of HMH, but showed reasonable performance. Findings support further investigation of the algorithm in a controlled and prospective clinical setting to determine whether it can independently screen noncontrast-enhanced head CT examinations and notify the interpreting radiologist of critical findings.

  20. Assessment of CT image quality using a Bayesian approach

    NASA Astrophysics Data System (ADS)

    Reginatto, M.; Anton, M.; Elster, C.

    2017-08-01

    One of the most promising approaches for evaluating CT image quality is task-specific quality assessment. This involves a simplified version of a clinical task, e.g. deciding whether an image belongs to the class of images that contain the signature of a lesion or not. Task-specific quality assessment can be done by model observers, which are mathematical procedures that carry out the classification task. The most widely used figure of merit for CT image quality is the area under the ROC curve (AUC), a quantity which characterizes the performance of a given model observer. In order to estimate AUC from a finite sample of images, different approaches from classical statistics have been suggested. The goal of this paper is to introduce task-specific quality assessment of CT images to metrology and to propose a novel Bayesian estimation of AUC for the channelized Hotelling observer (CHO) applied to the task of detecting a lesion at a known image location. It is assumed that signal-present and signal-absent images follow multivariate normal distributions with the same covariance matrix. The Bayesian approach results in a posterior distribution for the AUC of the CHO which provides in addition a complete characterization of the uncertainty of this figure of merit. The approach is illustrated by its application to both simulated and experimental data.