Sample records for observer-masked controlled study

  1. Respiratory source control using a surgical mask: An in vitro study.

    PubMed

    Patel, Rajeev B; Skaria, Shaji D; Mansour, Mohamed M; Smaldone, Gerald C

    2016-07-01

    Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an "N95 respirator") with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection.

  2. Respiratory source control using a surgical mask: An in vitro study

    PubMed Central

    Patel, Rajeev B.; Skaria, Shaji D.; Mansour, Mohamed M.; Smaldone, Gerald C.

    2016-01-01

    ABSTRACT Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an “N95 respirator”) with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection. PMID:26225807

  3. Contrast Gain Control Model Fits Masking Data

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Solomon, Joshua A.; Null, Cynthia H. (Technical Monitor)

    1994-01-01

    We studied the fit of a contrast gain control model to data of Foley (JOSA 1994), consisting of thresholds for a Gabor patch masked by gratings of various orientations, or by compounds of two orientations. Our general model includes models of Foley and Teo & Heeger (IEEE 1994). Our specific model used a bank of Gabor filters with octave bandwidths at 8 orientations. Excitatory and inhibitory nonlinearities were power functions with exponents of 2.4 and 2. Inhibitory pooling was broad in orientation, but narrow in spatial frequency and space. Minkowski pooling used an exponent of 4. All of the data for observer KMF were well fit by the model. We have developed a contrast gain control model that fits masking data. Unlike Foley's, our model accepts images as inputs. Unlike Teo & Heeger's, our model did not require multiple channels for different dynamic ranges.

  4. Photodetectors on Coronagraph Mask for Pointing Control

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatham

    2007-01-01

    It has been proposed to install a symmetrical array of photodetectors about the center of the mask of a coronagraph of the type used to search for planets orbiting remote stars. The purpose of this installation is to utilize the light from a star under observation as a guide in pointing the telescope. Simple arithmetic processing of the outputs of the photodetectors would provide indications of the lateral position of the center of the mask relative to the center of the image of the star. These indications could serve as pointing-control feedback signals for adjusting the telescope aim to center the image of the star on the mask. The widths of central mask areas available for placement of photodetectors differ among coronagraph designs, typically ranging upward from about 100 m. Arrays of photodetectors can readily be placed within areas in this size range. The number of detectors in an array could be as small as 4 or as large as 64. The upper limit on the number of detectors would be determined according to the extent of the occulting pattern and the number of functionalities, in addition to pointing control, to be served by the array.

  5. Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study.

    PubMed

    Winter, Susan; Thomas, Jane H; Stephens, Dianne P; Davis, Joshua S

    2010-03-01

    To determine the proportion of hospital staff who pass fit tests with each of three commonly used particulate face masks, and factors influencing preference and fit test results. Observational study. 50 healthy hospital staff volunteers in an 18-bed general intensive care unit in an Australian teaching hospital. Participants were administered a questionnaire about mask use and their preferred mask and underwent qualitative fit-testing with each of three different particulate masks: Kimberly-Clark Tecnol FluidShield N95 particulate filter respirator (KC), 3M Flat Fold 9320 particulate respirator and 3M 8822 particulate respirator with exhalation valve. Participants who failed fittesting were trained in correct mask donning, and fittesting was repeated. Proportion of participants who passed the fit test for each mask and the effect of training. The proportion of participants who passed a fit test was low for all three masks tested (KC, 16%; flat fold, 28%; and valved, 34%). Rates improved after training: the first mask tested fitted in 18% of participants pre-training and 40% post-training (P = 0.02). None of the masks fitted for 28% of participants. There were no significant predictors of fit-test results. A large proportion of individuals failed a fit test with any given mask, and we were not able to identify any factors that predicted mask fit in individuals. Training on mask use improved the rates of adequate fit. Hospitals should carry a range of P2 masks, and should conduct systematic P2 mask training and fit-testing programs for all staff potentially exposed to airborne pathogens.

  6. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness

    PubMed Central

    MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi

    2016-01-01

    Rationale Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Objective Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. Setting 6 major hospitals in 2 districts of Beijing, China. Design Cluster randomised controlled trial. Participants 245 index cases with ILI. Intervention Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Main outcome measure Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. Results In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. Conclusions The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. Trial registration number ACTRN12613000852752; Results. PMID:28039289

  7. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness.

    PubMed

    MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi

    2016-12-30

    Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. 6 major hospitals in 2 districts of Beijing, China. Cluster randomised controlled trial. 245 index cases with ILI. Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. ACTRN12613000852752; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Metacontrast masking and attention do not interact.

    PubMed

    Agaoglu, Sevda; Breitmeyer, Bruno; Ogmen, Haluk

    2016-07-01

    Visual masking and attention have been known to control the transfer of information from sensory memory to visual short-term memory. A natural question is whether these processes operate independently or interact. Recent evidence suggests that studies that reported interactions between masking and attention suffered from ceiling and/or floor effects. The objective of the present study was to investigate whether metacontrast masking and attention interact by using an experimental design in which saturation effects are avoided. We asked observers to report the orientation of a target bar randomly selected from a display containing either two or six bars. The mask was a ring that surrounded the target bar. Attentional load was controlled by set-size and masking strength by the stimulus onset asynchrony between the target bar and the mask ring. We investigated interactions between masking and attention by analyzing two different aspects of performance: (i) the mean absolute response errors and (ii) the distribution of signed response errors. Our results show that attention affects observers' performance without interacting with masking. Statistical modeling of response errors suggests that attention and metacontrast masking exert their effects by independently modulating the probability of "guessing" behavior. Implications of our findings for models of attention are discussed.

  9. Observation of EUVL mask using coherent EUV scatterometry microscope with high-harmonic-generation EUV source

    NASA Astrophysics Data System (ADS)

    Mamezaki, Daiki; Harada, Tetsuo; Nagata, Yutaka; Watanabe, Takeo

    2017-07-01

    In extreme ultraviolet (EUV) lithography, development of review tools for EUV mask pattern and phase defect at working wavelength of 13.5 nm is required. The EUV mask is composed of an absorber pattern (50 - 70 nm thick) and Mo/Si multilayer (280 nm thick) on a glass substrate. This mask pattern seems three-dimensional (3D) structure. This 3D structure would modulate EUV reflection phase, which would cause focus and pattern shifts. Thus, EUV phase imaging is important to evaluate this phase modulation. We have developed coherent EUV scatterometry microscope (CSM), which is a simple microscope without objective optics. EUV phase and intensity image are reconstructed with diffraction images by ptychography with coherent EUV illumination. The high-harmonic-generation (HHG) EUV source was employed for standalone CSM system. In this study, we updated HHG system of pump-laser reduction and gas-pressure control. Two types of EUV mask absorber patterns were observed. An 88-nm lines-and-spaces and a cross-line patterns were clearly reconstructed by ptychography. In addition, a natural defect with 2-μm diameter on the cross-line was well reconstructed. This demonstrated the high capability of the standalone CSM, which system will be used in the factories, such as mask shops and semiconductor fabrication plants.

  10. Clay jojoba oil facial mask for lesioned skin and mild acne--results of a prospective, observational pilot study.

    PubMed

    Meier, Larissa; Stange, Rainer; Michalsen, Andreas; Uehleke, Bernhard

    2012-01-01

    External application of clay facial masks is a cosmetic procedure generally used to reduce skin lesions and to improve overall skin condition. Collecting pilot data about self-treatment with clay jojoba oil masks on participants with acne-prone, lesioned skin and acne. Open, prospective, observational pilot study: Participants received written information, instructions, and questionnaires without direct contact with the study physician. For 6 weeks, they applied the masks 2-3 times per week. The primary outcome is the difference of skin lesions: baseline vs. after 6 weeks. 194 participants (192 female, 2 male, mean age (± SE) (32.3 ± 0.7 years) returned questionnaires and diaries. 133 of these participants returned complete and precise lesion counts (per-protocol (PP) collective). A 54% mean reduction in total lesion count was observed after 6 weeks of treatment with clay facial mask. Both inflammatory and non-inflammatory skin lesions were reduced significantly after treatment compared to baseline: Median counts (MC) of pustules per affected participant were reduced from 7.0 ± 0.9 to 3.0 ± 0.5 (mean individual reduction (MIR) = 49.4%), the MC of the papules from 3.5 ± 2.2 to 1.0 ± 0.4 (MIR = 57.3%), the MC of cysts from 2.0 ± 0.8 to 0.5 ± 0.4 (MIR = 68.6%) and the MC of comedones from 26.5 ± 6.3 to 16.0 ± 4.0 (MIR = 39.1%). DLQI-average score decreased from 5.0 ± 4.5 (mean ± SE) before to 2.1 ± 2.8 after treatment. The present study gives preliminary evidence that healing clay jojoba oil facial masks can be effective treatment for lesioned skin and mild acne vulgaris. Copyright © 2012 S. Karger AG, Basel.

  11. Oxygen therapy for cluster headache. A mask comparison trial. A single-blinded, placebo-controlled, crossover study.

    PubMed

    Petersen, Anja S; Barloese, Mads Cj; Lund, Nunu Lt; Jensen, Rigmor H

    2017-03-01

    Purpose The purpose of this article is to investigate possible differences in effect between three types of masks in the acute treatment of cluster headache (CH). Patients and methods Fifty-seven CH patients according to ICHD-II-criteria participated in a single-blinded, semi-randomized, placebo-controlled, crossover inpatient study, and 102 CH attacks were treated with 100% oxygen delivered by demand valve oxygen (DVO), O 2 ptimask or simple mask (15 liters/min) or placebo delivered by DVO for 15 minutes. Primary endpoint: Two-point decrease of pain on a five-point rating scale within 15 minutes. Results Only 10 CH patients had multiple attacks and reached the point of placebo. There were no significant differences between masks in the primary endpoints ( p = 0.412). After 15 minutes 48% had a two-point decrease using the DVO compared to 45% with placebo ( p = 0.867). After 30 minutes 68% were pain free or had pain relief using DVO and 45% by placebo ( p = 0.061). The DVO was preferred by 62% compared to 5% and 33% for simple mask ( p < 0.0001) and O 2 ptimask ( p = 0.061). In the first attack the DVO was significantly better at achieving pain relief at 15 minutes ( p = 0.018). Treatment with DVO or O 2 ptimask reduced the need for rescue medication compared to the simple mask (23%, 19%, 50%, respectively). No treatment-related adverse events were observed. Conclusion The primary endpoint with pain relief at 15 minutes was non-significant; however, a post hoc analysis of the first attack significantly favored DVO. Further, therapy by O 2 ptimask and DVO resulted in a decreased need for rescue medication. We recommend that CH patients be offered DVO or O 2 ptimask before oxygen therapy is abandoned.

  12. Mask aligner for ultrahigh vacuum with capacitive distance control

    NASA Astrophysics Data System (ADS)

    Bhaskar, Priyamvada; Mathioudakis, Simon; Olschewski, Tim; Muckel, Florian; Bindel, Jan Raphael; Pratzer, Marco; Liebmann, Marcus; Morgenstern, Markus

    2018-04-01

    We present a mask aligner driven by three piezomotors which guides and aligns a SiN shadow mask under capacitive control towards a sample surface. The three capacitors for read out are located at the backside of the thin mask such that the mask can be placed at a μm distance from the sample surface, while keeping it parallel to the surface, without touching the sample by the mask a priori. Samples and masks can be exchanged in-situ and the mask can additionally be displaced parallel to the surface. We demonstrate an edge sharpness of the deposited structures below 100 nm, which is likely limited by the diffusion of the deposited Au on Si(111).

  13. Supreme Laryngeal Mask Airway versus Face Mask during Neonatal Resuscitation: A Randomized Controlled Trial.

    PubMed

    Trevisanuto, Daniele; Cavallin, Francesco; Nguyen, Loi Ngoc; Nguyen, Tien Viet; Tran, Linh Dieu; Tran, Chien Dinh; Doglioni, Nicoletta; Micaglio, Massimo; Moccia, Luciano

    2015-08-01

    To assess the effectiveness of supreme laryngeal mask airway (SLMA) over face mask ventilation for preventing need for endotracheal intubation at birth. We report a prospective, randomized, parallel 1:1, unblinded, controlled trial. After a short-term educational intervention on SLMA use, infants ≥34-week gestation and/or expected birth weight ≥1500 g requiring positive pressure ventilation (PPV) at birth were randomized to resuscitation by SLMA or face mask. The primary outcome was the success rate of the resuscitation devices (SLMA or face mask) defined as the achievement of an effective PPV preventing the need for endotracheal intubation. We enrolled 142 patients (71 in SLMA and 71 in face mask group, respectively). Successful resuscitation rate was significantly higher with the SLMA compared with face mask ventilation (91.5% vs 78.9%; P = .03). Apgar score at 5 minutes was significantly higher in SLMA than in face mask group (P = .02). Neonatal intensive care unit admission rate was significantly lower in SLMA than in face mask group (P = .02). No complications related to the procedure occurred. In newborns with gestational age ≥34 weeks and/or expected birth weight ≥1500 g needing PPV at birth, the SLMA is more effective than face mask to prevent endotracheal intubation. The SLMA is effective in clinical practice after a short-term educational intervention. Registered with ClinicalTrials.gov: NCT01963936. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Face mask use and control of respiratory virus transmission in households.

    PubMed

    MacIntyre, C Raina; Cauchemez, Simon; Dwyer, Dominic E; Seale, Holly; Cheung, Pamela; Browne, Gary; Fasher, Michael; Wood, James; Gao, Zhanhai; Booy, Robert; Ferguson, Neil

    2009-02-01

    Many countries are stockpiling face masks for use as a nonpharmaceutical intervention to control virus transmission during an influenza pandemic. We conducted a prospective cluster-randomized trial comparing surgical masks, non-fit-tested P2 masks, and no masks in prevention of influenza-like illness (ILI) in households. Mask use adherence was self-reported. During the 2006 and 2007 winter seasons, 286 exposed adults from 143 households who had been exposed to a child with clinical respiratory illness were recruited. We found that adherence to mask use significantly reduced the risk for ILI-associated infection, but <50% of participants wore masks most of the time. We concluded that household use of face masks is associated with low adherence and is ineffective for controlling seasonal respiratory disease. However, during a severe pandemic when use of face masks might be greater, pandemic transmission in households could be reduced.

  15. Study of shape evaluation for mask and silicon using large field of view

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Shinoda, Shinichi; Toyoda, Yasutaka

    2010-09-01

    We have developed a highly integrated method of mask and silicon metrology. The aim of this integration is evaluating the performance of the silicon corresponding to Hotspot on a mask. It can use the mask shape of a large field, besides. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. As an optimal solution to these issues, we provide a DFM solution that extracts 2-dimensional data for a more realistic and error-free simulation by reproducing accurately the contour of the actual mask, in addition to the simulation results from the mask data. On the other hand, there is roughness in the silicon form made from a mass-production line. Moreover, there is variation in the silicon form. For this reason, quantification of silicon form is important, in order to estimate the performance of a pattern. In order to quantify, the same form is equalized in two dimensions. And the method of evaluating based on the form is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. •Discrimination of nuisance defects for fine pattern. •Determination of two-dimensional variability of

  16. Respiratory Source Control Using Surgical Masks With Nanofiber Media

    PubMed Central

    Skaria, Shaji D.; Smaldone, Gerald C.

    2014-01-01

    Background: Potentially infected individuals (‘source’) are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others (‘receiver’). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Methods: Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of ‘infectious’ aerosols from the ‘source’ to a ‘receiver’). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an ‘N95 respirator’). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Results: Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, ‘infected’ source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face

  17. Respiratory source control using surgical masks with nanofiber media.

    PubMed

    Skaria, Shaji D; Smaldone, Gerald C

    2014-07-01

    Potentially infected individuals ('source') are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others ('receiver'). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of 'infectious' aerosols from the 'source' to a 'receiver'). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an 'N95 respirator'). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, 'infected' source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced

  18. Using a high-flow nasal cannula provides superior results to OxyMask delivery in moderate to severe bronchiolitis: a randomized controlled study.

    PubMed

    Ergul, Ayse Betul; Calıskan, Emrah; Samsa, Hasan; Gokcek, Ikbal; Kaya, Ali; Zararsiz, Gozde Erturk; Torun, Yasemin Altuner

    2018-06-18

    The effectiveness of using a face mask with a small diffuser for oxygen delivery (OxyMask) was compared to use of a high-flow nasal cannula (HFNC) in patients with moderate or severe bronchiolitis.The study population in this open, phase 4, randomized controlled trial consisted of 60 patients aged 1-24 months diagnosed with moderate or severe bronchiolitis and admitted to an intensive care unit (ICU) for oxygen therapy. The patients were randomized into two groups according to the method of oxygen delivery: a diffuser mask group and an HFNC group.There were seven failures in the mask group and none in the HFNC group. The survival probability differed significantly between the two treatment methods (p = 0.009).Time to weaning off oxygen therapy was 56 h in the HFNC group and 96 h in the mask group (p < 0.001). HFNC use decreased the treatment failure rate and the duration of both oxygen therapy and ICU treatment compared to the diffuser mask, which implies that an HFNC should be the first choice for treating patients admitted to the ICU with severe bronchiolitis. What is known: • A high-flow nasal cannula (HFNC) does not significantly reduce the time on oxygen compared to standard therapy in children with moderate to severe bronchiolitis. Observational studies show that, since the introduction of HFNC, fewer children with bronchiolitis need intubation. For children with moderate to severe bronchiolitis there is no proof of its benefit. What Is New: • In children with moderate to severe bronchiolitis, HFNC provides faster and more effective improvement than can be achieved with a diffuser mask.

  19. Behind the mask. Journey through an epidemic: some observations of contrasting public health responses to SARS

    PubMed Central

    Syed, Q; Sopwith, W; Regan, M; Bellis, M

    2003-01-01

    SARS has been called the first global epidemic of the 21st century and has been the cause of a massive and varied public health response in many countries of the world. This report describes observations made by two authors on a journey from Manchester in the United Kingdom to Chiang Mai in Thailand during the peak of global transmission. The public response to SARS, particularly characterised by the wearing of face masks, seemed to outstrip official guidance. Though of uncertain protective benefit, the wearing of masks may have contributed to the awareness of the collective and personal responsibility in combating infectious disease. Active and empowered involvement of the general public in implementing and cooperating with public health control measures supported by national and international authorities has clearly helped to bring SARS under control. The public health significance of such potent symbols as the face mask may be considered in strategies to tackle other emerging infections. PMID:14600109

  20. A multicentre phase III randomised controlled single-masked clinical trial evaluating the clinical efficacy and safety of light-masks at preventing dark-adaptation in the treatment of early diabetic macular oedema (CLEOPATRA): study protocol for a randomised controlled trial.

    PubMed

    Sivaprasad, Sobha; Arden, Geoffrey; Prevost, A Toby; Crosby-Nwaobi, Roxanne; Holmes, Helen; Kelly, Joanna; Murphy, Caroline; Rubin, Gary; Vasconcelos, Joanna; Hykin, Philip

    2014-11-22

    This study will evaluate hypoxia, as a novel concept in the pathogenesis of diabetic macular oedema (DMO). As the oxygen demand of the eye is maximum during dark-adaptation, we hypothesize that wearing light-masks during sleep will cause regression and prevent the development and progression of DMO. The study protocol comprises both an efficacy and mechanistic evaluation to test this hypothesis. This is a phase III randomised controlled single-masked multicentre clinical trial to test the clinical efficacy of light-masks at preventing dark-adaptation in the treatment of non-central DMO. Three hundred patients with non-centre-involving DMO in at least one eye will be randomised 1:1 to light-masks and control masks (with no light) to be used during sleep at night for a period of 24 months. The primary outcome is regression of non-central oedema by assessing change in the zone of maximal retinal thickness at baseline on optical coherence tomography (SD-OCT). Secondary outcomes will evaluate the prevention of development and progression of DMO by assessing changes in retinal thickness in different regions of the macula, macular volume, refracted visual acuity and level of retinopathy. Safety parameters will include sleep disturbance. Adverse events and measures of compliance will be assessed over 24 months. Participants recruited to the mechanistic sub-study will have additional retinal oximetry, multifocal electroretinography (ERG) and microperimetry to evaluate the role of hypoxia by assessing and comparing changes induced by supplemental oxygen and the light-masks at 12 months. The outcomes of this study will provide insight into the pathogenesis of DMO and provide evidence on whether a simple, non-invasive device in the form of a light-mask can help prevent the progression to centre-involving DMO and visual impairment in people with diabetes.

  1. Metacontrast masking is processed before grapheme-color synesthesia.

    PubMed

    Bacon, Michael Patrick; Bridgeman, Bruce; Ramachandran, Vilayanur S

    2013-01-01

    We investigated the physiological mechanism of grapheme-color synesthesia using metacontrast masking. A metacontrast target is rendered invisible by a mask that is delayed by about 60 ms; the target and mask do not overlap in space or time. Little masking occurs, however, if the target and mask are simultaneous. This effect must be cortical, because it can be obtained dichoptically. To compare the data for synesthetes and controls, we developed a metacontrast design in which nonsynesthete controls showed weaker dichromatic masking (i.e., the target and mask were in different colors) than monochromatic masking. We accomplished this with an equiluminant target, mask, and background for each observer. If synesthetic color affected metacontrast, synesthetes should show monochromatic masking more similar to the weak dichromatic masking among controls, because synesthetes could add their synesthetic color to the monochromatic condition. The target-mask pairs used for each synesthete were graphemes that elicited strong synesthetic colors. We found stronger monochromatic than dichromatic U-shaped metacontrast for both synesthetes and controls, with optimal masking at an asynchrony of 66 ms. The difference in performance between the monochromatic and dichromatic conditions in the synesthetes indicates that synesthesia occurs at a later processing stage than does metacontrast masking.

  2. Flavored Anesthetic Masks for Inhalational Induction in Children.

    PubMed

    Gupta, Aakriti; Mathew, Preethy Joseph; Bhardwaj, Neerja

    2017-10-01

    To evaluate the clinical efficacy of masking the odor of inhalational agents using fruit flavors on the anxiety behavior and compliance of children for inhalational induction. A prospective randomized double blind, placebo controlled study was conducted on 60 unpremedicated children in the age group of 4-12 y. Thirty children received anesthetic masks smeared with a flavor of child's choice while the other 30 children were induced using masks without flavor. Anxiety was assessed using modified Yale Pre-operative Anxiety Scale (mYPAS) in the pre-op room and during inhalational induction. Mask acceptance was graded by Induction Compliance Checklist (ICC). The cost-effectiveness of flavored anesthetic masks was compared to that of commercially available pre-scented masks. The baseline anxiety in the two groups was comparable. The number of children demonstrating high levels of anxiety at anesthetic induction was similar in flavored and non-flavored mask groups (p 0.45). The compliance to mask induction was also equally good (p 0.99). The authors found significant difference in the cost of flavored mask (INR 56.45 per mask) as compared to commercially available pre-scented masks (INR 660 per mask). The authors observed a placebo effect that reduced the pre-op anxiety in the control group which probably made the quality of induction equivalent with flavored and non-flavored masks. Therefore, using a flavored anesthetic mask is cost-effective than using a commercially available pre-scented mask.

  3. A Randomized Controlled Study of Art Observation Training to Improve Medical Student Ophthalmology Skills.

    PubMed

    Gurwin, Jaclyn; Revere, Karen E; Niepold, Suzannah; Bassett, Barbara; Mitchell, Rebecca; Davidson, Stephanie; DeLisser, Horace; Binenbaum, Gil

    2018-01-01

    Observation and description are critical to the practice of medicine, and to ophthalmology in particular. However, medical education does not provide explicit training in these areas, and medical students are often criticized for deficiencies in these skills. We sought to evaluate the effects of formal observation training in the visual arts on the general and ophthalmologic observational skills of medical students. Randomized, single-masked, controlled trial. Thirty-six first-year medical students, randomized 1:1 into art-training and control groups. Students in the art-training group were taught by professional art educators at the Philadelphia Museum of Art, during 6 custom-designed, 1.5-hour art observation sessions over a 3-month period. All subjects completed pre- and posttesting, in which they described works of art, retinal pathology images, and external photographs of eye diseases. Grading of written descriptions for observational and descriptive abilities by reviewers using an a priori rubric and masked to group assignment and pretesting/posttesting status. Observational skills, as measured by description testing, improved significantly in the training group (mean change +19.1 points) compared with the control group (mean change -13.5 points), P = 0.001. There were significant improvements in the training vs. control group for each of the test subscores. In a poststudy questionnaire, students reported applying the skills they learned in the museum in clinically meaningful ways at medical school. Art observation training for first-year medical students can improve clinical ophthalmology observational skills. Principles from the field of visual arts, which is reputed to excel in teaching observation and descriptive abilities, can be successfully applied to medical training. Further studies can examine the impact of such training on clinical care. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Model of visual contrast gain control and pattern masking

    NASA Technical Reports Server (NTRS)

    Watson, A. B.; Solomon, J. A.

    1997-01-01

    We have implemented a model of contrast gain and control in human vision that incorporates a number of key features, including a contrast sensitivity function, multiple oriented bandpass channels, accelerating nonlinearities, and a devisive inhibitory gain control pool. The parameters of this model have been optimized through a fit to the recent data that describe masking of a Gabor function by cosine and Gabor masks [J. M. Foley, "Human luminance pattern mechanisms: masking experiments require a new model," J. Opt. Soc. Am. A 11, 1710 (1994)]. The model achieves a good fit to the data. We also demonstrate how the concept of recruitment may accommodate a variant of this model in which excitatory and inhibitory paths have a common accelerating nonlinearity, but which include multiple channels tuned to different levels of contrast.

  5. What's in a mask? Information masking with forward and backward visual masks.

    PubMed

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  6. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers.

    PubMed

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-04-22

    The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go

  7. A cluster randomised trial of cloth masks compared with medical masks in healthcare workers

    PubMed Central

    MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi

    2015-01-01

    Objective The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. Setting 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. Participants 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Intervention Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Main outcome measure Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. Results The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. Conclusions This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Trial registration number Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. PMID

  8. Coronagraph Focal-Plane Phase Masks Based on Photonic Crystal Technology: Recent Progress and Observational Strategy

    NASA Technical Reports Server (NTRS)

    Murakami, Naoshi; Nishikawa, Jun; Sakamoto, Moritsugu; Ise, Akitoshi; Oka, Kazuhiko; Baba, Naoshi; Murakami, Hiroshi; Tamura, Motohide; Traub, Wesley A.; Mawet, Dimitri; hide

    2012-01-01

    Photonic crystal, an artificial periodic nanostructure of refractive indices, is one of the attractive technologies for coronagraph focal-plane masks aiming at direct imaging and characterization of terrestrial extrasolar planets. We manufactured the eight-octant phase mask (8OPM) and the vector vortex mask (VVM) very precisely using the photonic crystal technology. Fully achromatic phase-mask coronagraphs can be realized by applying appropriate polarization filters to the masks. We carried out laboratory experiments of the polarization-filtered 8OPM coronagraph using the High-Contrast Imaging Testbed (HCIT), a state-of-the-art coronagraph simulator at the Jet Propulsion Laboratory (JPL). We report the experimental results of 10-8-level contrast across several wavelengths over 10% bandwidth around 800nm. In addition, we present future prospects and observational strategy for the photonic-crystal mask coronagraphs combined with differential imaging techniques to reach higher contrast. We proposed to apply a polarization-differential imaging (PDI) technique to the VVM coronagraph, in which we built a two-channel coronagraph using polarizing beam splitters to avoid a loss of intensity due to the polarization filters. We also proposed to apply an angular-differential imaging (ADI) technique to the 8OPM coronagraph. The 8OPM/ADI mode avoids an intensity loss due to a phase transition of the mask and provides a full field of view around central stars. We present results of preliminary laboratory demonstrations of the PDI and ADI observational modes with the phase-mask coronagraphs.

  9. A mask quality control tool for the OSIRIS multi-object spectrograph

    NASA Astrophysics Data System (ADS)

    López-Ruiz, J. C.; Vaz Cedillo, Jacinto Javier; Ederoclite, Alessandro; Bongiovanni, Ángel; González Escalera, Víctor

    2012-09-01

    OSIRIS multi object spectrograph uses a set of user-customised-masks, which are manufactured on-demand. The manufacturing process consists of drilling the specified slits on the mask with the required accuracy. Ensuring that slits are on the right place when observing is of vital importance. We present a tool for checking the quality of the process of manufacturing the masks which is based on analyzing the instrument images obtained with the manufactured masks on place. The tool extracts the slit information from these images, relates specifications with the extracted slit information, and finally communicates to the operator if the manufactured mask fulfills the expectations of the mask designer. The proposed tool has been built using scripting languages and using standard libraries such as opencv, pyraf and scipy. The software architecture, advantages and limits of this tool in the lifecycle of a multiobject acquisition are presented.

  10. Retention of pediatric bag-mask ventilation efficacy skill by inexperienced medical student resuscitators using standard bag-mask ventilation masks, pocket masks, and blob masks.

    PubMed

    Kitagawa, Kory H; Nakamura, Nina M; Yamamoto, Loren

    2006-03-01

    To measure the ventilation efficacy with three single-sized mask types on infant and child manikin models. Medical students were recruited as study subjects inasmuch as they are inexperienced resuscitators. They were taught proper bag-mask ventilation (BMV) according to the American Heart Association guidelines on an infant and a child manikin. Subjects completed a BMV attempt successfully using the adult standard mask (to simulate the uncertainty of mask selection), pocket mask, and blob mask. Each attempt consisted of 5 ventilations assessed by chest rise of the manikin. Study subjects were asked which mask was easiest to use. Four to six weeks later, subjects repeated the procedure with no instructions (to simulate an emergency BMV encounter without immediate pre-encounter teaching). Forty-six volunteer subjects were studied. During the first attempt, subjects preferred the standard and blob masks over the pocket mask. For the second attempt, the blob mask was preferred over the standard mask, and few liked the pocket mask. Using the standard, blob, and pocket masks on the child manikin, 39, 42, and 20 subjects, respectively, were able to achieve adequate ventilation. Using the standard, blob, and pocket masks on the infant manikin, 45, 45, and 11 subjects, respectively, were able to achieve adequate ventilation. Both the standard and blob masks are more effective than the pocket mask at achieving adequate ventilation on infant and child manikins in this group of inexperienced medical student resuscitators, who most often preferred the blob mask.

  11. Influence of face mask design on bag-valve-mask ventilation performance: a randomized simulation study.

    PubMed

    Na, J U; Han, S K; Choi, P C; Cho, J H; Shin, D H

    2013-10-01

    Different face mask designs can influence bag-valve-mask (BVM) ventilation performance during resuscitation. We compared a single-use, air-cushioned face mask (AM) with a reusable silicone face mask (SM) for quality of BVM ventilation on a manikin simulating cardiac arrest. Thirty-two physicians were recruited, and a prospective, randomized, crossover observational study was conducted after an American Heart Association-accredited basic life support provider course and standardized practice time were completed. Participants performed 12 cycles of BVM ventilation with both the AM and SM on a SmartMan lung simulator. Mean tidal volume was significantly higher in ventilations performed using the AM vs. the SM (548 ± 159 ml vs. 439 ± 163 ml, P < 0.01). In addition, the proportion of low-volume ventilation was significantly lower with the AM than the SM [6/12 (2-11) vs. 9/12 (5-12), P = 0.03]. Bag-valve-AM ventilation volume was not affected by the physical characteristics of the rescuers, except for sex. In contrast, bag-valve-SM ventilation volume was affected by most of the characteristics tested, including sex, height, weight, hand width, hand length, and grip power. The AM seems to be a more efficient face mask than the SM at delivering sufficient ventilation volumes. The performance of the AM did not seem to be associated with the physical characteristics of the rescuers, whereas that of the SM was affected by these factors. The SM may not be an appropriate face mask for performing one-person BVM ventilation during resuscitation for rescuers who are smaller in stature, have a smaller hand size, or have weaker grip power. © 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Masked and unmasked error-related potentials during continuous control and feedback

    NASA Astrophysics Data System (ADS)

    Lopes Dias, Catarina; Sburlea, Andreea I.; Müller-Putz, Gernot R.

    2018-06-01

    The detection of error-related potentials (ErrPs) in tasks with discrete feedback is well established in the brain–computer interface (BCI) field. However, the decoding of ErrPs in tasks with continuous feedback is still in its early stages. Objective. We developed a task in which subjects have continuous control of a cursor’s position by means of a joystick. The cursor’s position was shown to the participants in two different modalities of continuous feedback: normal and jittered. The jittered feedback was created to mimic the instability that could exist if participants controlled the trajectory directly with brain signals. Approach. This paper studies the electroencephalographic (EEG)—measurable signatures caused by a loss of control over the cursor’s trajectory, causing a target miss. Main results. In both feedback modalities, time-locked potentials revealed the typical frontal-central components of error-related potentials. Errors occurring during the jittered feedback (masked errors) were delayed in comparison to errors occurring during normal feedback (unmasked errors). Masked errors displayed lower peak amplitudes than unmasked errors. Time-locked classification analysis allowed a good distinction between correct and error classes (average Cohen-, average TPR  =  81.8% and average TNR  =  96.4%). Time-locked classification analysis between masked error and unmasked error classes revealed results at chance level (average Cohen-, average TPR  =  60.9% and average TNR  =  58.3%). Afterwards, we performed asynchronous detection of ErrPs, combining both masked and unmasked trials. The asynchronous detection of ErrPs in a simulated online scenario resulted in an average TNR of 84.0% and in an average TPR of 64.9%. Significance. The time-locked classification results suggest that the masked and unmasked errors were indistinguishable in terms of classification. The asynchronous classification results suggest that the

  13. Face mask use by patients in primary care.

    PubMed

    Tischendorf, Jessica S; Temte, Jonathan L

    2012-02-01

    Face masks are recommended for patients with respiratory symptoms to reduce influenza transmission. Little knowledge exists regarding actual utilization and acceptance of face masks in primary care. Compare distribution of face masks to clinic and community trends in respiratory infection (RI) and influenza-like illness (ILI); estimate the annual need for face masks in primary care. Retrospective observational study of practice data from a 31-week period starting in October 2009. Family practice clinic in Madison, Wis. Patients with fever, cough, or other respiratory symptoms as evaluated by reception staff. Age, sex, and weekly counts of individuals receiving a face mask, as well as counts of RI and ILI patients based on ICD-9 coding from 27 statewide clinics. Face mask counts were 80% of RI counts for the clinic and reflected the demographics of the clinic population. Distribution was correlated to prevalence of RI (R = 0.783, P < 0.001) and ILI (R = 0.632, P < 0.001). Annually, 8% of clinic visits were for RI. The high percentage of face mask use among RI patients reflects the feasibility of this intervention to help control influenza transmission in a primary care setting. Using the present data, clinics can estimate the annual need for face masks.

  14. Competing for Consciousness: Prolonged Mask Exposure Reduces Object Substitution Masking

    ERIC Educational Resources Information Center

    Goodhew, Stephanie C.; Visser, Troy A. W.; Lipp, Ottmar V.; Dux, Paul E.

    2011-01-01

    In object substitution masking (OSM) a sparse, temporally trailing 4-dot mask impairs target identification, even though it has different contours from, and does not spatially overlap with the target. Here, we demonstrate a previously unknown characteristic of OSM: Observers show reduced masking at prolonged (e.g., 640 ms) relative to intermediate…

  15. SatCam: A mobile application for coordinated ground/satellite observation of clouds and validation of satellite-derived cloud mask products.

    NASA Astrophysics Data System (ADS)

    Gumley, L.; Parker, D.; Flynn, B.; Holz, R.; Marais, W.

    2011-12-01

    SatCam is an application for iOS devices that allows users to collect observations of local cloud and surface conditions in coordination with an overpass of the Terra, Aqua, or NPP satellites. SatCam allows users to acquire images of sky conditions and ground conditions at their location anywhere in the world using the built-in iPhone or iPod Touch camera at the same time that the satellite is passing overhead and viewing their location. Immediately after the sky and ground observations are acquired, the application asks the user to rate the level of cloudiness in the sky (Completely Clear, Mostly Clear, Partly Cloudy, Overcast). For the ground observation, the user selects their assessment of the surface conditions (Urban, Green Vegetation, Brown Vegetation, Desert, Snow, Water). The sky condition and surface condition selections are stored along with the date, time, and geographic location for the images, and the images are uploaded to a central server. When the MODIS (Terra and Aqua) or VIIRS (NPP) imagery acquired over the user location becomes available, a MODIS or VIIRS true color image centered at the user's location is delivered back to the SatCam application on the user's iOS device. SSEC also proposes to develop a community driven SatCam website where users can share their observations and assessments of satellite cloud products in a collaborative environment. SSEC is developing a server side data analysis system to ingest the SatCam user observations, apply quality control, analyze the sky images for cloud cover, and collocate the observations with MODIS and VIIRS satellite products (e.g., cloud mask). For each observation that is collocated with a satellite observation, the server will determine whether the user scored a "hit", meaning their sky observation and sky assessment matched the automated cloud mask obtained from the satellite observation. The hit rate will be an objective assessment of the accuracy of the user's sky observations. Users with

  16. Nasal mask ventilation is better than face mask ventilation in edentulous patients.

    PubMed

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.

  17. Anticipating and controlling mask costs within EDA physical design

    NASA Astrophysics Data System (ADS)

    Rieger, Michael L.; Mayhew, Jeffrey P.; Melvin, Lawrence S.; Lugg, Robert M.; Beale, Daniel F.

    2003-08-01

    For low k1 lithography, more aggressive OPC is being applied to critical layers, and the number of mask layers with OPC treatments is growing rapidly. The 130 nm, process node required, on average, 8 layers containing rules- or model-based OPC. The 90 nm node will have 16 OPC layers, of which 14 layers contain aggressive model-based OPC. This escalation of mask pattern complexity, coupled with the predominant use of vector-scan e-beam (VSB) mask writers contributes to the rising costs of advanced mask sets. Writing times for OPC layouts are several times longer than for traditional layouts, making mask exposure the single largest cost component for OPC masks. Lower mask yields, another key factor in higher mask costs, is also aggravated by OPC. Historical mask set costs are plotted below. The initial cost of a 90 nm-node mask set will exceed one million dollars. The relative impact of mask cost on chip depends on how many total wafers are printed with each mask set. For many foundry chips, where unit production is often well below 1000 wafers, mask costs are larger than wafer processing costs. Further increases in NRE may begin to discourage these suppliers' adoption to 90 nm and smaller nodes. In this paper we will outline several alternatives for reducing mask costs by strategically leveraging dimensional margins. Dimensional specifications for a particular masking layer usually are applied uniformly to all features on that layer. As a practical matter, accuracy requirements on different features in the design may vary widely. Take a polysilicon layer, for example: global tolerance specifications for that layer are driven by the transistor-gate requirements; but these parameters over-specify interconnect feature requirements. By identifying features where dimensional accuracy requirements can be reduced, additional margin can be leveraged to reduce OPC complexity. Mask writing time on VSB tools will drop in nearly direct proportion to reduce shot count. By

  18. A New MRI Masking Technique Based on Multi-Atlas Brain Segmentation in Controls and Schizophrenia: A Rapid and Viable Alternative to Manual Masking.

    PubMed

    Del Re, Elisabetta C; Gao, Yi; Eckbo, Ryan; Petryshen, Tracey L; Blokland, Gabriëlla A M; Seidman, Larry J; Konishi, Jun; Goldstein, Jill M; McCarley, Robert W; Shenton, Martha E; Bouix, Sylvain

    2016-01-01

    Brain masking of MRI images separates brain from surrounding tissue and its accuracy is important for further imaging analyses. We implemented a new brain masking technique based on multi-atlas brain segmentation (MABS) and compared MABS to masks generated using FreeSurfer (FS; version 5.3), Brain Extraction Tool (BET), and Brainwash, using manually defined masks (MM) as the gold standard. We further determined the effect of different masking techniques on cortical and subcortical volumes generated by FreeSurfer. Images were acquired on a 3-Tesla MR Echospeed system General Electric scanner on five control and five schizophrenia subjects matched on age, sex, and IQ. Automated masks were generated from MABS, FS, BET, and Brainwash, and compared to MM using these metrics: a) volume difference from MM; b) Dice coefficients; and c) intraclass correlation coefficients. Mean volume difference between MM and MABS masks was significantly less than the difference between MM and FS or BET masks. Dice coefficient between MM and MABS was significantly higher than Dice coefficients between MM and FS, BET, or Brainwash. For subcortical and left cortical regions, MABS volumes were closer to MM volumes than were BET or FS volumes. For right cortical regions, MABS volumes were closer to MM volumes than were BET volumes. Brain masks generated using FreeSurfer, BET, and Brainwash are rapidly obtained, but are less accurate than manually defined masks. Masks generated using MABS, in contrast, resemble more closely the gold standard of manual masking, thereby offering a rapid and viable alternative. Copyright © 2015 by the American Society of Neuroimaging.

  19. Is tinnitus an early voice of masked hypertension? High masked hypertension rate in patients with tinnitus.

    PubMed

    Gun, Taylan; Özkan, Selçuk; Yavuz, Bunyamin

    2018-04-23

    Tinnitus is hearing a sound without any external acoustic stimulus. There are some clues of hypertension can cause tinnitus in different ways. The aim of the study was to evaluate the relationship between tinnitus and masked hypertension including echocardiographic parameters and severity of tinnitus. This study included 88 patients with tinnitus of at least 3 months duration and 85 age and gender-matched control subjects. Tinnitus severity index was used to classify the patients with tinnitus. After a complete medical history, all subjects underwent routine laboratory examination, office blood pressure measurement, hearing tests and ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of masked hypertension was significantly higher in patients with tinnitus than controls (18.2% vs 3.5%, p = 0.002). Office diastolic BP (76 ± 8.1 vs. 72.74 ± 8.68, p = 0.01), ambulatory 24-H diastolic BP (70.2 ± 9.6 vs. 66.9 ± 6.1, p = 0.07) and ambulatory daytime diastolic BP (73.7 ± 9.5 vs. 71.1 ± 6.2, p = 0.03) was significantly higher in patients with tinnitus than control group. Tinnitus severity index in patients without masked hypertension was 0 and tinnitus severity index in patients with masked hypertension were 2 (1-5). This study demonstrated that masked hypertension must be kept in mind if there is a complaint of tinnitus without any other obvious reason.

  20. Nasal mask ventilation is better than face mask ventilation in edentulous patients

    PubMed Central

    Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil

    2016-01-01

    Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. Results: A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Conclusion: Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients. PMID:27625477

  1. Observational Studies: Cohort and Case-Control Studies

    PubMed Central

    Song, Jae W.; Chung, Kevin C.

    2010-01-01

    Observational studies are an important category of study designs. To address some investigative questions in plastic surgery, randomized controlled trials are not always indicated or ethical to conduct. Instead, observational studies may be the next best method to address these types of questions. Well-designed observational studies have been shown to provide results similar to randomized controlled trials, challenging the belief that observational studies are second-rate. Cohort studies and case-control studies are two primary types of observational studies that aid in evaluating associations between diseases and exposures. In this review article, we describe these study designs, methodological issues, and provide examples from the plastic surgery literature. PMID:20697313

  2. On the effectiveness of noise masks: naturalistic vs. un-naturalistic image statistics.

    PubMed

    Hansen, Bruce C; Hess, Robert F

    2012-05-01

    It has been argued that the human visual system is optimized for identification of broadband objects embedded in stimuli possessing orientation averaged power spectra fall-offs that obey the 1/f(β) relationship typically observed in natural scene imagery (i.e., β=2.0 on logarithmic axes). Here, we were interested in whether individual spatial channels leading to recognition are functionally optimized for narrowband targets when masked by noise possessing naturalistic image statistics (β=2.0). The current study therefore explores the impact of variable β noise masks on the identification of narrowband target stimuli ranging in spatial complexity, while simultaneously controlling for physical or perceived differences between the masks. The results show that β=2.0 noise masks produce the largest identification thresholds regardless of target complexity, and thus do not seem to yield functionally optimized channel processing. The differential masking effects are discussed in the context of contrast gain control. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Feedforward and feedback control in apraxia of speech: effects of noise masking on vowel production.

    PubMed

    Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H

    2015-04-01

    This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed.

  4. Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production

    PubMed Central

    Mailend, Marja-Liisa; Guenther, Frank H.

    2015-01-01

    Purpose This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Results Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. Conclusion The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed. PMID:25565143

  5. Left ventricular mass of persistent masked hypertension in Hong Kong Chinese adolescents: a 4-year follow-up study.

    PubMed

    Yam, Man-Ching; So, Hung-Kwan; Kwok, Sit-Yee; Lo, Fung-Cheung; Mok, Chi-Fung; Leung, Chuk-Kwan; Yip, Wai-Kwok; Sung, Yn-Tz

    2018-06-01

    In our previous study, the prevalence of childhood masked hypertension was 11%. This study aims to assess the left ventricular mass index of persistent masked hypertension and determine the factors of elevated left ventricular mass index in Hong Kong Chinese adolescents from a community cohort. Community prospective cohort study, follow-up of a case-control study in community. Patients with masked hypertension at baseline were invited to recheck ambulatory blood pressure for the persistence of masked hypertension. A total of 144 out of 165 patients with masked hypertension in the 2011/2012 ambulatory blood pressure survey consented to participate in the study. In all, 48 patients were found to have persistent masked hypertension by ambulatory blood pressure rechecking and were matched with normotensive controls by sex, age, and body height. The left ventricular mass (117.3±39.9 g versus 87.0±28.2 g versus 102.0±28.2 g) and left ventricular mass index (30.1±8.4 g/m2.7 versus 23.9±6.3 g/m2.7 versus 25.1±5.7 g/m2.7) were significantly higher in the persistent masked hypertension group (p<0.0001) compared with the patients without persistent masked hypertension and controls. In multivariate linear regression analysis, left ventricular mass index was found to be higher in male gender (β=4.874, p<0.0001) and the patients with persistent masked hypertension (β=2.796, p=0.003). In addition, left ventricular mass index was positively associated with body mass index z-score (β=3.045, p<0.0001) and low-density lipoprotein cholesterol concentration (β=1.634, p=0.015). Persistent masked hypertension in adolescents is associated with elevated left ventricular mass index.

  6. Object Substitution Masking: When Does Mask Preview Work?

    ERIC Educational Resources Information Center

    Lim, Stephen Wee Hun; Chua, Fook K.

    2008-01-01

    When a target is enclosed by a 4-dot mask that persists after the target disappears, target identification is worse than it is when the mask terminates with the target. This masking effect is attributed to object substitution masking (OSM). Previewing the mask, however, attenuates OSM. This study investigated specific conditions under which mask…

  7. Blood Pressure Control in Hypertensive Patients, Cardiovascular Risk Profile and the Prevalence of Masked Uncontrolled Hypertension (MUCH).

    PubMed

    Naser, Nabil; Dzubur, Alen; Durak, Azra; Kulic, Mehmed; Naser, Nura

    2016-07-27

    The term masked hypertension (MH) should be used for untreated individuals who have normal office blood pressure but elevated ambulatory blood pressure. For treated patients, this condition should be termed masked uncontrolled hypertension (MUCH). Masked uncontrolled hypertension (MUCH) has gone unrecognized because few studies have used 24-h ABPM to determine the prevalence of suboptimal BP control in seemingly well-treated patients, and there are few such studies in large cohorts of treated patients attending usual clinical practice. This is important because masked hypertension is associated with a high risk of cardiovascular events. This study was conducted to obtain more information about the association between hypertension and other CV risk factors, about office and ambulatory blood pressure (BP) control as well as on cardiovascular (CV) risk profile in treated hypertensive patients, also to define the prevalence and characteristics of masked uncontrolled hypertension (MUCH) among treated hypertensive patients in routine clinical practice. In this study 2514 male and female patients were included during a period of 5 years follow up. All patients have ambulatory blood pressure monitoring (ABPM) for at least 24h. We identified patients with treated and controlled BP according to current international guidelines (clinic BP, 140/90mmHg). Cardiovascular risk assessment was based on personal history, clinic BP values, as well as target organ damage evaluation. Masked uncontrolled hypertension (MUCH) was diagnosed in these patients if despite controlled clinic BP, the mean 24-h ABPM average remained elevated (24-h systolic BP ≥130mmHg and/or 24-h diastolic BP ≥80mmHg). Patients had a mean age of 60.2+10 years, and the majority of them (94.6%) were followed by specialist physicians. Average clinic BP was 150.4+16/89.9+12 mmHg. About 70% of patients displayed a very high-risk profile. Ambulatory blood pressure monitoring (ABPM) was performed in all recruited

  8. Comparison of the OxyMask and Venturi mask in the delivery of supplemental oxygen: Pilot study in oxygen-dependent patients

    PubMed Central

    Beecroft, Jaime M; Hanly, Patrick J

    2006-01-01

    BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia. METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a randomized, single-blind, cross-over design. Baseline blood oxygen saturation (SaO2) was established breathing room air, followed in a random order by supplemental oxygen through the OxyMask or Venturi mask. Oxygen delivery was titrated to maintain SaO2 4% to 5% and 8% to 9% above baseline for two separate 30 min periods of stable breathing. Oxygen flow rate, partial pressure of inspired and expired oxygen (PO2) and carbon dioxide (PCO2), minute ventilation, heart rate, nasal and oral breathing, SaO2 and transcutaneous PCO2 were collected continuously. The study was repeated following alterations to the OxyMask design, which improved clearance of carbon dioxide. RESULTS: Thirteen patients, aged 28 to 79 years, were studied initially using the original OxyMask. Oxygen flow rate was lower, inspired PO2 was higher and expired PO2 was lower while using the OxyMask. Minute ventilation and inspired and expired PCO2 were significantly higher while using the OxyMask, whereas transcutaneous PCO2, heart rate and the ratio of nasal to oral breathing did not change significantly throughout the study. Following modification of the OxyMask, 13 additional patients, aged 18 to 79 years, were studied using the same protocol. The modified OxyMask provided a higher inspired PO2 at a lower flow rate, without evidence of carbon dioxide retention. CONCLUSIONS: Oxygen is delivered safely and more efficiently by the OxyMask than by the Venturi mask in stable oxygen-dependent patients. PMID:16896425

  9. Effect of Masked Regions on Weak-lensing Statistics

    NASA Astrophysics Data System (ADS)

    Shirasaki, Masato; Yoshida, Naoki; Hamana, Takashi

    2013-09-01

    Sky masking is unavoidable in wide-field weak-lensing observations. We study how masks affect the measurement of statistics of matter distribution probed by weak gravitational lensing. We first use 1000 cosmological ray-tracing simulations to examine in detail the impact of masked regions on the weak-lensing Minkowski Functionals (MFs). We consider actual sky masks used for a Subaru Suprime-Cam imaging survey. The masks increase the variance of the convergence field and the expected values of the MFs are biased. The bias then compromises the non-Gaussian signals induced by the gravitational growth of structure. We then explore how masks affect cosmological parameter estimation. We calculate the cumulative signal-to-noise ratio (S/N) for masked maps to study the information content of lensing MFs. We show that the degradation of S/N for masked maps is mainly determined by the effective survey area. We also perform simple χ2 analysis to show the impact of lensing MF bias due to masked regions. Finally, we compare ray-tracing simulations with data from a Subaru 2 deg2 survey in order to address if the observed lensing MFs are consistent with those of the standard cosmology. The resulting χ2/n dof = 29.6/30 for three combined MFs, obtained with the mask effects taken into account, suggests that the observational data are indeed consistent with the standard ΛCDM model. We conclude that the lensing MFs are a powerful probe of cosmology only if mask effects are correctly taken into account.

  10. EFFECT OF MASKED REGIONS ON WEAK-LENSING STATISTICS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shirasaki, Masato; Yoshida, Naoki; Hamana, Takashi, E-mail: masato.shirasaki@utap.phys.s.u-tokyo.ac.jp

    2013-09-10

    Sky masking is unavoidable in wide-field weak-lensing observations. We study how masks affect the measurement of statistics of matter distribution probed by weak gravitational lensing. We first use 1000 cosmological ray-tracing simulations to examine in detail the impact of masked regions on the weak-lensing Minkowski Functionals (MFs). We consider actual sky masks used for a Subaru Suprime-Cam imaging survey. The masks increase the variance of the convergence field and the expected values of the MFs are biased. The bias then compromises the non-Gaussian signals induced by the gravitational growth of structure. We then explore how masks affect cosmological parameter estimation.more » We calculate the cumulative signal-to-noise ratio (S/N) for masked maps to study the information content of lensing MFs. We show that the degradation of S/N for masked maps is mainly determined by the effective survey area. We also perform simple {chi}{sup 2} analysis to show the impact of lensing MF bias due to masked regions. Finally, we compare ray-tracing simulations with data from a Subaru 2 deg{sup 2} survey in order to address if the observed lensing MFs are consistent with those of the standard cosmology. The resulting {chi}{sup 2}/n{sub dof} = 29.6/30 for three combined MFs, obtained with the mask effects taken into account, suggests that the observational data are indeed consistent with the standard {Lambda}CDM model. We conclude that the lensing MFs are a powerful probe of cosmology only if mask effects are correctly taken into account.« less

  11. Functional neuroanatomy of visual masking deficits in schizophrenia.

    PubMed

    Green, Michael F; Lee, Junghee; Cohen, Mark S; Engel, Steven A; Korb, Alexander S; Nuechterlein, Keith H; Wynn, Jonathan K; Glahn, David C

    2009-12-01

    Visual masking procedures assess the earliest stages of visual processing. Patients with schizophrenia reliably show deficits on visual masking, and these procedures have been used to explore vulnerability to schizophrenia, probe underlying neural circuits, and help explain functional outcome. To identify and compare regional brain activity associated with one form of visual masking (ie, backward masking) in schizophrenic patients and healthy controls. Subjects received functional magnetic resonance imaging scans. While in the scanner, subjects performed a backward masking task and were given 3 functional localizer activation scans to identify early visual processing regions of interest (ROIs). University of California, Los Angeles, and the Department of Veterans Affairs Greater Los Angeles Healthcare System. Nineteen patients with schizophrenia and 19 healthy control subjects. Main Outcome Measure The magnitude of the functional magnetic resonance imaging signal during backward masking. Two ROIs (lateral occipital complex [LO] and the human motion selective cortex [hMT+]) showed sensitivity to the effects of masking, meaning that signal in these areas increased as the target became more visible. Patients had lower activation than controls in LO across all levels of visibility but did not differ in other visual processing ROIs. Using whole-brain analyses, we also identified areas outside the ROIs that were sensitive to masking effects (including bilateral inferior parietal lobe and thalamus), but groups did not differ in signal magnitude in these areas. The study results support a key role in LO for visual masking, consistent with previous studies in healthy controls. The current results indicate that patients fail to activate LO to the same extent as controls during visual processing regardless of stimulus visibility, suggesting a neural basis for the visual masking deficit, and possibly other visual integration deficits, in schizophrenia.

  12. Forward masking of frequency modulationa

    PubMed Central

    Byrne, Andrew J.; Wojtczak, Magdalena; Viemeister, Neal F.

    2012-01-01

    Forward masking of sinusoidal frequency modulation (FM) was measured with three types of maskers: FM, amplitude modulation (AM), and a masker created by combining the magnitude spectrum of an FM tone with random component phases. For the signal FM rates used (5, 20, and 40 Hz), an FM masker raised detection thresholds in terms of frequency deviation by a factor of about 5 relative to without a masker. The AM masker produced a much smaller effect, suggesting that FM-to-AM conversion did not contribute substantially to the FM forward masking. The modulation depth of an FM masker had a nonmonotonic effect, with maximal masking observed at an intermediate value within the range of possible depths, while the random-phase FM masker produced less masking, arguing against a spectrally-based explanation for FM forward masking. Broad FM-rate selectivity for forward masking was observed for both 4-kHz and 500-Hz carriers. Thresholds measured as a function of the masker-signal delay showed slow recovery from FM forward masking, with residual masking for delays up to 500 ms. The FM forward-masking effect resembles that observed for AM [Wojtczak and Viemeister (2005). J. Acoust. Soc. Am. 188, 3198–3210] and may reflect modulation-rate selective neural adaptation to FM. PMID:23145618

  13. Manufacturability study of masks created by inverse lithography technology (ILT)

    NASA Astrophysics Data System (ADS)

    Martin, Patrick M.; Progler, C. J.; Xiao, G.; Gray, R.; Pang, L.; Liu, Y.

    2005-11-01

    As photolithography is pushed to fabricate deep-sub wavelength devices for 90nm, 65nm and smaller technology nodes using available exposure tools (i.e., 248nm, 193nm steppers), photomask capability is becoming extremely critical. For example, PSM masks require more complicated processing; aggressive OPC makes the writing time longer and sometimes unpredictable; and, high MEEF imposes much more stringent demands on mask quality. Therefore, in order for any new lithography technology to be adopted into production, mask manufacturability must be studied thoroughly and carefully. In this paper we will present the mask manufacturability study on mask patterns created using Inverse Lithography Technology (ILT). Unlike conventional OPC methodologies, ILT uses a unique outcome-based technology to mathematically determine the mask features that produce the desired on-wafer results. ILT solves the most critical litho challenges of the deep sub-wavelength era. Potential benefits include: higher yield; expanded litho process windows; superb pattern fidelity at 90, 65 & 45-nm nodes; and reduced time-to-silicon - all without changing the existing lithography infrastructure and design-to-silicon flow. In this study a number of cell structures were selected and used as test patterns. "Luminized patterns" were generated for binary mask and attenuated phase-shift mask. Both conventional OPC patterns and "luminized patterns" were put on a test reticle side by side, and they all have a number of variations in term of correction aggressivity level and mask complexity. Mask manufacturability, including data fracturing, writing time, mask inspection, and metrology were studied. The results demonstrate that, by optimizing the inspection recipe, masks created using ILT technology can be made and qualified using current processes with a reasonable turn-around time.

  14. Effects of hard mask etch on final topography of advanced phase shift masks

    NASA Astrophysics Data System (ADS)

    Hortenbach, Olga; Rolff, Haiko; Lajn, Alexander; Baessler, Martin

    2017-07-01

    Continuous shrinking of the semiconductor device dimensions demands steady improvements of the lithographic resolution on wafer level. These requirements challenge the photomask industry to further improve the mask quality in all relevant printing characteristics. In this paper topography of the Phase Shift Masks (PSM) was investigated. Effects of hard mask etch on phase shift uniformity and mask absorber profile were studied. Design of experiments method (DoE) was used for the process optimization, whereas gas composition, bias power of the hard mask main etch and bias power of the over-etch were varied. In addition, influence of the over-etch time was examined at the end of the experiment. Absorber depth uniformity, sidewall angle (SWA), reactive ion etch lag (RIE lag) and through pitch (TP) dependence were analyzed. Measurements were performed by means of Atomic-force microscopy (AFM) using critical dimension (CD) mode with a boot-shaped tip. Scanning electron microscope (SEM) cross-section images were prepared to verify the profile quality. Finally CD analysis was performed to confirm the optimal etch conditions. Significant dependence of the absorber SWA on hard mask (HM) etch conditions was observed revealing an improvement potential for the mask absorber profile. It was found that hard mask etch can leave a depth footprint in the absorber layer. Thus, the etch depth uniformity of hard mask etch is crucial for achieving a uniform phase shift over the active mask area. The optimized hard mask etch process results in significantly improved mask topography without deterioration of tight CD specifications.

  15. Mask process correction (MPC) modeling and its application to EUV mask for electron beam mask writer EBM-7000

    NASA Astrophysics Data System (ADS)

    Kamikubo, Takashi; Ohnishi, Takayuki; Hara, Shigehiro; Anze, Hirohito; Hattori, Yoshiaki; Tamamushi, Shuichi; Bai, Shufeng; Wang, Jen-Shiang; Howell, Rafael; Chen, George; Li, Jiangwei; Tao, Jun; Wiley, Jim; Kurosawa, Terunobu; Saito, Yasuko; Takigawa, Tadahiro

    2010-09-01

    In electron beam writing on EUV mask, it has been reported that CD linearity does not show simple signatures as observed with conventional COG (Cr on Glass) masks because they are caused by scattered electrons form EUV mask itself which comprises stacked heavy metals and thick multi-layers. To resolve this issue, Mask Process Correction (MPC) will be ideally applicable. Every pattern is reshaped in MPC. Therefore, the number of shots would not increase and writing time will be kept within reasonable range. In this paper, MPC is extended to modeling for correction of CD linearity errors on EUV mask. And its effectiveness is verified with simulations and experiments through actual writing test.

  16. Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    NASA Technical Reports Server (NTRS)

    Newman, Kevin; Belikov, Ruslan; Pluzhnik, Eugene; Balasubramanian, Kunjithapatham; Wilson, Dan

    2014-01-01

    Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.

  17. The use of masks and respirators to prevent transmission of influenza: a systematic review of the scientific evidence

    PubMed Central

    bin‐Reza, Faisal; Lopez Chavarrias, Vicente; Nicoll, Angus; Chamberland, Mary E.

    2011-01-01

    Please cite this paper as: bin‐Reza et al. (2012) The use of masks and respirators to prevent transmission of influenza: a systematic review of the scientific evidence. Influenza and Other Respiratory Viruses 6(4), 257–267. There are limited data on the use of masks and respirators to reduce transmission of influenza. A systematic review was undertaken to help inform pandemic influenza guidance in the United Kingdom. The initial review was performed in November 2009 and updated in June 2010 and January 2011. Inclusion criteria included randomised controlled trials and quasi‐experimental and observational studies of humans published in English with an outcome of laboratory‐confirmed or clinically‐diagnosed influenza and other viral respiratory infections. There were 17 eligible studies. Six of eight randomised controlled trials found no significant differences between control and intervention groups (masks with or without hand hygiene; N95/P2 respirators). One household trial found that mask wearing coupled with hand sanitiser use reduced secondary transmission of upper respiratory infection/influenza‐like illness/laboratory‐confirmed influenza compared with education; hand sanitiser alone resulted in no reduction. One hospital‐based trial found a lower rate of clinical respiratory illness associated with non‐fit‐tested N95 respirator use compared with medical masks. Eight of nine retrospective observational studies found that mask and/or respirator use was independently associated with a reduced risk of severe acute respiratory syndrome (SARS). Findings, however, may not be applicable to influenza and many studies were suboptimal. None of the studies established a conclusive relationship between mask/respirator use and protection against influenza infection. Some evidence suggests that mask use is best undertaken as part of a package of personal protection especially hand hygiene. The effectiveness of masks and respirators is likely linked to

  18. Maximizing noise energy for noise-masking studies.

    PubMed

    Jules Étienne, Cédric; Arleo, Angelo; Allard, Rémy

    2017-08-01

    Noise-masking experiments are widely used to investigate visual functions. To be useful, noise generally needs to be strong enough to noticeably impair performance, but under some conditions, noise does not impair performance even when its contrast approaches the maximal displayable limit of 100 %. To extend the usefulness of noise-masking paradigms over a wider range of conditions, the present study developed a noise with great masking strength. There are two typical ways of increasing masking strength without exceeding the limited contrast range: use binary noise instead of Gaussian noise or filter out frequencies that are not relevant to the task (i.e., which can be removed without affecting performance). The present study combined these two approaches to further increase masking strength. We show that binarizing the noise after the filtering process substantially increases the energy at frequencies within the pass-band of the filter given equated total contrast ranges. A validation experiment showed that similar performances were obtained using binarized-filtered noise and filtered noise (given equated noise energy at the frequencies within the pass-band) suggesting that the binarization operation, which substantially reduced the contrast range, had no significant impact on performance. We conclude that binarized-filtered noise (and more generally, truncated-filtered noise) can substantially increase the energy of the noise at frequencies within the pass-band. Thus, given a limited contrast range, binarized-filtered noise can display higher energy levels than Gaussian noise and thereby widen the range of conditions over which noise-masking paradigms can be useful.

  19. Orthostatic hypertension as a predisposing factor for masked hypertension: the J-SHIPP study.

    PubMed

    Tabara, Yasuharu; Igase, Michiya; Miki, Tetsuro; Ohyagi, Yasumasa; Matsuda, Fumihiko; Kohara, Katsuhiko

    2016-09-01

    Masked hypertension (HT) is a known risk factor for cardiovascular outcomes. Postural blood pressure (BP) dysregulation is another BP phenomenon representing cardiovascular frailty. Given their several shared risk factors, we suspected an inter-relationship between these two BP phenomena. Here we investigated a possible relationship between masked HT and postural BP dysregulation in a general population. Study subjects were 884 apparently healthy individuals (aged 66.3±8.9 years). Masked HT was assessed on the basis of the ambulatory monitored average awake BP and office-measured BP values. Orthostatic BP change was measured at our office after a subject was asked to actively stand up. A strong inverse relationship was noted for orthostatic systolic BP (SBP) change and office-to-awake SBP differences (office-awake BP) (r=-0.422, P<0.001), and these relationships were replicated in the second-visit measurements (n=101, r=-0.326, P=0.001). Multivariate analysis revealed that the inverse association was independent (β=-0.23, P<0.001) of possible covariates, including baseline office BP and antihypertensive treatment. Orthostatic HT (OHT), which is defined as postural increases in SBP >10 mm Hg, 3 min after standing (P=0.001), but not transient HT at only 1 min (P=0.767), was associated with greater office-to-awake SBP differences than in orthostatic normotensive subjects. Among apparently normotensive subjects, the frequency of masked HT was therefore significantly greater in subjects who showed OHT 3 min after standing (52.1%) compared with controls (27.5%) (odds ratio=3.01, P=0.001). We observed an intra-individual relationship between the postural BP change and the office-to-awake BP differences, and subjects who showed OHT were likely to have masked HT irrespective of antihypertensive treatment.

  20. Mask ventilation with two different face masks in the delivery room for preterm infants: a randomized controlled trial.

    PubMed

    Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M

    2015-07-01

    If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants <33 weeks gestational age in the delivery room. Infants born at the Royal Alexandra Hospital from April to September 2013 at <33 weeks gestational age who received mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.

  1. Inhibitory masking controls the threshold sensitivity of retinal ganglion cells

    PubMed Central

    Pan, Feng; Toychiev, Abduqodir; Zhang, Yi; Atlasz, Tamas; Ramakrishnan, Hariharasubramanian; Roy, Kaushambi; Völgyi, Béla; Akopian, Abram

    2016-01-01

    Key points Retinal ganglion cells (RGCs) in dark‐adapted retinas show a range of threshold sensitivities spanning ∼3 log units of illuminance.Here, we show that the different threshold sensitivities of RGCs reflect an inhibitory mechanism that masks inputs from certain rod pathways.The masking inhibition is subserved by GABAC receptors, probably on bipolar cell axon terminals.The GABAergic masking inhibition appears independent of dopaminergic circuitry that has been shown also to affect RGC sensitivity.The results indicate a novel mechanism whereby inhibition controls the sensitivity of different cohorts of RGCs. This can limit and thereby ensure that appropriate signals are carried centrally in scotopic conditions when sensitivity rather than acuity is crucial. Abstract The responses of rod photoreceptors, which subserve dim light vision, are carried through the retina by three independent pathways. These pathways carry signals with largely different sensitivities. Retinal ganglion cells (RGCs), the output neurons of the retina, show a wide range of sensitivities in the same dark‐adapted conditions, suggesting a divergence of the rod pathways. However, this organization is not supported by the known synaptic morphology of the retina. Here, we tested an alternative idea that the rod pathways converge onto single RGCs, but inhibitory circuits selectively mask signals so that one pathway predominates. Indeed, we found that application of GABA receptor blockers increased the sensitivity of most RGCs by unmasking rod signals, which were suppressed. Our results indicate that inhibition controls the threshold responses of RGCs under dim ambient light. This mechanism can ensure that appropriate signals cross the bottleneck of the optic nerve in changing stimulus conditions. PMID:27350405

  2. Shadows alter facial expressions of Noh masks.

    PubMed

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers' recognition of the emotional expressions. In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa's smile. They also agree with the aesthetic principle of Japanese traditional art "yugen (profound grace and subtlety)", which highly appreciates subtle emotional expressions in the darkness.

  3. Effects of non-simultaneous masking on the binaural masking level difference

    PubMed Central

    Buss, Emily; Hall III, Joseph W.

    2011-01-01

    The present study sought to clarify the role of non-simultaneous masking in the binaural masking level difference for maskers that fluctuate in level. In the first experiment the signal was a brief 500-Hz tone, and the masker was a bandpass noise (100–2000 Hz), with the initial and final 200-ms bursts presented at 40-dB spectrum level and the inter-burst gap presented at 20-dB spectrum level. Temporal windows were fitted to thresholds measured for a range of gap durations and signal positions within the gap. In the second experiment, individual differences in out of phase (NoSπ) thresholds were compared for a brief signal in a gapped bandpass masker, a brief signal in a steady bandpass masker, and a long signal in a narrowband (50-Hz-wide) noise masker. The third experiment measured brief tone detection thresholds in forward, simultaneous, and backward masking conditions for a 50- and for a 1900-Hz-wide noise masker centered on the 500-Hz signal frequency. Results are consistent with comparable temporal resolution in the in phase (NoSo) and NoSπ conditions and no effect of temporal resolution on individual observers’ ability to utilize binaural cues in narrowband noise. The large masking release observed for a narrowband noise masker may be due to binaural masking release from non-simultaneous, informational masking. PMID:21361448

  4. Masking technique for coating thickness control on large and strongly curved aspherical optics.

    PubMed

    Sassolas, B; Flaminio, R; Franc, J; Michel, C; Montorio, J-L; Morgado, N; Pinard, L

    2009-07-01

    We discuss a method to control the coating thickness deposited onto large and strongly curved optics by ion beam sputtering. The technique uses an original design of the mask used to screen part of the sputtered materials. A first multielement mask is calculated from the measured two-dimensional coating thickness distribution. Then, by means of an iterative process, the final mask is designed. By using such a technique, it has been possible to deposit layers of tantalum pentoxide having a high thickness gradient onto a curved substrate 500 mm in diameter. Residual errors in the coating thickness profile are below 0.7%.

  5. Lightweight Face Mask

    NASA Technical Reports Server (NTRS)

    Cason, W. E. I.; Baucom, R. M.; Evans, R. C.

    1982-01-01

    Lightweight face mask originally developed to protect epileptic patients during seizures could have many other medical and nonmedical applications such as muscular distrophy patients, football linesmen and riot-control police. Masks are extremely lightweight, the lightest of the configurations weighing only 136 grams.

  6. Alternating phase-shift mask and binary mask for 45-nm node and beyond: the impact on the mask error control

    NASA Astrophysics Data System (ADS)

    Kojima, Yosuke; Shirasaki, Masanori; Chiba, Kazuaki; Tanaka, Tsuyoshi; Inazuki, Yukio; Yoshikawa, Hiroki; Okazaki, Satoshi; Iwase, Kazuya; Ishikawa, Kiichi; Ozawa, Ken

    2007-05-01

    For 45 nm node and beyond, the alternating phase-shift mask (alt. PSM), one of the most expected resolution enhancement technologies (RET) because of its high image contrast and small mask error enhancement factor (MEEF), and the binary mask (BIM) attract attention. Reducing CD and registration errors and defect are their critical issues. As the solution, the new blank for alt. PSM and BIM is developed. The top film of new blank is thin Cr, and the antireflection film and shielding film composed of MoSi are deposited under the Cr film. The mask CD performance is evaluated for through pitch, CD linearity, CD uniformity, global loading, resolution and pattern fidelity, and the blank performance is evaluated for optical density, reflectivity, sheet resistance, flatness and defect level. It is found that the performance of new blank is equal to or better than that of conventional blank in all items. The mask CD performance shows significant improvement. The lithography performance of new blank is confirmed by wafer printing and AIMS measurement. The full dry type alt. PSM has been used as test plate, and the test results show that new blank can almost meet the specifications of pi-0 CD difference, CD uniformity and process margin for 45 nm node. Additionally, the new blank shows the better pattern fidelity than that of conventional blank on wafer. AIMS results are almost same as wafer results except for the narrowest pattern. Considering the result above, this new blank can reduce the mask error factors of alt. PSM and BIM for 45 nm node and beyond.

  7. Active membrane masks for improved overlay performance in proximity lithography

    NASA Astrophysics Data System (ADS)

    Huston, Dryver R.; Plumpton, James; Esser, Brian; Sullivan, Gerald A.

    2004-07-01

    Membrane masks are thin (2 micron x 35 mm x 35 mm) structures that carry the master exposure patterns in proximity (X-ray) lithography. With the continuous drive to the printing of ever-finer features in microelectronics, the reduction of mask-wafer overlay positioning errors by passive rigid body positioning and passive stress control in the mask becomes impractical due to nano and sub-micron scale elastic deformations in the membrane mask. This paper describes the design, mechanics and performance of a system for actively stretching a membrane mask in-plane to control overlay distortion. The method uses thermoelectric heating/cooling elements placed on the mask perimeter. The thermoelectric elements cause controlled thermoelastic deformations in the supporting wafer, which in turn corrects distortions in the membrane mask. Silicon carbide masks are the focus of this study, but the method is believed to be applicable to other mask materials, such as diamond. Experimental and numerical results will be presented, as well as a discussion of the design issues and related design decisions.

  8. Masked Hypertension is Associated With Cognitive Decline in Geriatric Age-Geriatric MASked Hypertension and Cognition (G-MASH-cog) Study.

    PubMed

    Esme, Mert; Yavuz, Burcu Balam; Yavuz, Bunyamin; Asil, Serkan; Tuna Dogrul, Rana; Sumer, Fatih; Kilic, Mustafa Kemal; Kizilarslanoglu, Muhammet Cemal; Varan, Hacer Dogan; Sagir, Aykut; Balci, Cafer; Halil, Meltem; Cankurtaran, Mustafa

    2018-01-16

    Masked hypertension is described as high ambulatory blood pressure measurements (ABPM) where office blood pressure measurements are normal. Effect of hypertension on cognitive functions is well known. However, the effect of masked hypertension on cognitive functions is unclear. The aim of this study is to examine the relationship between masked hypertension and cognitive functions. One hundred-two normotensive patients admitted to the Geriatric Medicine outpatient clinic were included. Exclusion criteria were hypertension, dementia, major depression, and usage of antihypertensive medication. All patients underwent ABPM procedures and average daytime blood pressure, mean blood pressure at night and the 24-hour average blood pressure measurements were recorded. Comprehensive geriatric assessment tests and neuropsychological tests were administered. The diagnosis of masked hypertension was based on the definitions in the 2013 guideline of the European Society of Cardiology. Forty-four patients (43%) were diagnosed with masked hypertension. Patients with masked hypertension had significantly lower scores on Mini-Mental State Examination (MMSE) test, Quick Mild Cognitive Impairment Test (QMCI), and Categorical Fluency Test than the normotensive patients (p = .011; p = .046; and p = .004; respectively). Montreal Cognitive Assessment Scale test score was lower in masked hypertension, although this was not statistically significant. This study may indicate that geriatric patients with masked hypertension, compared to normotensive patients have decreased cognitive functions. Masked hypertension should be kept in mind while assessing older adults. When masked hypertension is detected, cognitive assessment is essential to diagnose possible cognitive dysfunction at early stage. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Human observers have optimal introspective access to perceptual processes even for visually masked stimuli

    PubMed Central

    Peters, Megan A K; Lau, Hakwan

    2015-01-01

    Many believe that humans can ‘perceive unconsciously’ – that for weak stimuli, briefly presented and masked, above-chance discrimination is possible without awareness. Interestingly, an online survey reveals that most experts in the field recognize the lack of convincing evidence for this phenomenon, and yet they persist in this belief. Using a recently developed bias-free experimental procedure for measuring subjective introspection (confidence), we found no evidence for unconscious perception; participants’ behavior matched that of a Bayesian ideal observer, even though the stimuli were visually masked. This surprising finding suggests that the thresholds for subjective awareness and objective discrimination are effectively the same: if objective task performance is above chance, there is likely conscious experience. These findings shed new light on decades-old methodological issues regarding what it takes to consider a neurobiological or behavioral effect to be 'unconscious,' and provide a platform for rigorously investigating unconscious perception in future studies. DOI: http://dx.doi.org/10.7554/eLife.09651.001 PMID:26433023

  10. Development for 2D pattern quantification method on mask and wafer

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Toyoda, Yasutaka; Wang, Zhigang

    2010-03-01

    We have developed the effective method of mask and silicon 2-dimensional metrology. The aim of this method is evaluating the performance of the silicon corresponding to Hotspot on a mask. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. 2-dimensional Shape quantification is important as optimal solution over these problems. Although 1-dimensional shape measurement has been performed by the conventional technique, 2-dimensional shape management is needed in the mass production line under the influence of RET. We developed the technique of analyzing distribution of shape edge performance as the shape management technique. On the other hand, there is roughness in the silicon shape made from a mass-production line. Moreover, there is variation in the silicon shape. For this reason, quantification of silicon shape is important, in order to estimate the performance of a pattern. In order to quantify, the same shape is equalized in two dimensions. And the method of evaluating based on the shape is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. It is possible to analyze variability of the edge of the same position with high precision. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and

  11. MC1R studies in dogs with melanistic mask or brindle patterns.

    PubMed

    Schmutz, S M; Berryere, T G; Ellinwood, N M; Kerns, J A; Barsh, G S

    2003-01-01

    Black mask is a characteristic pattern in which red, yellow, tan, fawn, or brindle dogs exhibit a melanistic muzzle which may extend up onto the ears. Melanistic mask is inherited in several breeds as an autosomal dominant trait, and appears to be a fixed trait in a few breeds of dogs. A MC1R nonsense mutation, R306ter, has been shown to cause a completely red or yellow coat color in certain breeds such as Irish setters, yellow Labrador retrievers, and golden retrievers. The amino acid sequence for the melanocortin receptor 1 gene (MC1R) was examined in 17 dogs with melanistic masks from seven breeds, 19 dogs without melanistic masks, and 7 dogs in which their coat color made the mask difficult to distinguish. We also examined nine brindle dogs of four breeds, including three dogs who also had a black mask. No consistent amino acid change was observed in the brindle dogs. All dogs with a melanistic mask had at least one copy of a valine substitution for methionine at amino acid 264 (M264V) and none were homozygous for the premature stop codon (R306ter). These results suggest that black mask, but not brindle, is caused by a specific MC1R allele.

  12. 2012 Mask Industry Survey

    NASA Astrophysics Data System (ADS)

    Malloy, Matt; Litt, Lloyd C.

    2012-11-01

    A survey supported by SEMATECH and administered by David Powell Consulting was sent to semiconductor industry leaders to gather information about the mask industry as an objective assessment of its overall condition. The survey was designed with the input of semiconductor company mask technologists and merchant mask suppliers. 2012 marks the 11th consecutive year for the mask industry survey. This year's survey and reporting structure are similar to those of the previous years with minor modifications based on feedback from past years and the need to collect additional data on key topics. Categories include general mask information, mask processing, data and write time, yield and yield loss, delivery times, and maintenance and returns. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. Results, initial observations, and key comparisons between the 2011 and 2012 survey responses are shown here, including multiple indications of a shift towards the manufacturing of higher end photomasks.

  13. Controlling bridging and pinching with pixel-based mask for inverse lithography

    NASA Astrophysics Data System (ADS)

    Kobelkov, Sergey; Tritchkov, Alexander; Han, JiWan

    2016-03-01

    Inverse Lithography Technology (ILT) has become a viable computational lithography candidate in recent years as it can produce mask output that results in process latitude and CD control in the fab that is hard to match with conventional OPC/SRAF insertion approaches. An approach to solving the inverse lithography problem as a nonlinear, constrained minimization problem over a domain mask pixels was suggested in the paper by Y. Granik "Fast pixel-based mask optimization for inverse lithography" in 2006. The present paper extends this method to satisfy bridging and pinching constraints imposed on print contours. Namely, there are suggested objective functions expressing penalty for constraints violations, and their minimization with gradient descent methods is considered. This approach has been tested with an ILT-based Local Printability Enhancement (LPTM) tool in an automated flow to eliminate hotspots that can be present on the full chip after conventional SRAF placement/OPC and has been applied in 14nm, 10nm node production, single and multiple-patterning flows.

  14. Photorefractive keratectomy at 193 nm using an erodible mask

    NASA Astrophysics Data System (ADS)

    Gordon, Michael; Brint, Stephen F.; Durrie, Daniel S.; Seiler, Theo; Friedman, Marc D.; Johnsson, N. M. F.; King, Michael C.; Muller, David F.

    1992-08-01

    Clinical experience with more than ten thousand sighted eyes has demonstrated great promise for correcting myopia with photorefractive keratectomy (PRK). Previously reported techniques have incorporated computer-controlled irises, diaphragms, and apertures to regulate the desired distribution of 193 nm radiation onto the eye. This paper reports on an entirely new approach for performing PRK which utilizes an erodible mask to control the shape transfer process. Compared to the more traditional techniques, the erodible mask offers promise of correcting a broad range of refractive errors. In this paper the erodible mask and associated hardware are described in detail. We describe the shape transfer experiments used to predict the functional relationship between the desired refractive correction and the mask shape. We report on early clinical results from five patients with myopic astigmatism. We conclude that the early shape transfer experiments overestimated the spherical component of the correction by 1.25 diopters and underestimated the cylindrical component by approximately 0.85 diopters. The data suggest there may be biological effects which evoke different healing responses when myopic PRK corrections are performed with and without astigmatism. Clinical trials are proceeding with the mask shapes adjusted for these observations.

  15. A double-masked, placebo-controlled study of fluoxetine for hypochondriasis.

    PubMed

    Fallon, Brian A; Petkova, Eva; Skritskaya, Natalia; Sanchez-Lacay, Arturo; Schneier, Franklin; Vermes, Donna; Cheng, Jianfeng; Liebowitz, Michael R

    2008-12-01

    This study assessed the efficacy, durability, and tolerability of fluoxetine for hypochondriasis, a disorder for which controlled pharmacological trials are scarce. Fifty-seven patients with hypochondriasis were enrolled: 12 discontinued during the placebo run-in, and 45 were randomized to either fluoxetine or placebo for 12 weeks (acute treatment). Responder status was defined as a Clinical Global Impression rating for hypochondriasis of much or very much improved. Secondary outcome measures included severity of hypochondriasis, somatization, anxiety, and depression. Responders to acute treatment entered a 12-week maintenance phase to week 24. Sustained responders at week 24 entered a 12-week double-masked discontinuation phase. Primary analysis used the intent-to-treat sample. More patients responded with improvement in hypochondriasis when given fluoxetine compared with placebo, starting at week 8 (50.0% vs 19.0%, P = 0.03) and continuing to week 12 (62.5% vs 33.3%, P = 0.05). Mean dose at week 12 dose was 51.4 mg (SD, +/-23 mg). The acute treatment response was maintained to week 24 with more responders in the fluoxetine compared with the placebo group (54.2% vs 23.8%, P = 0.04). Significant improvement was not noted on the continuous secondary outcomes measures of hypochondriasis, with the exception of the Clinical Global Impression hypochondriasis severity scale at week 24. Likelihood of response was not associated with severity of psychiatric comorbidity. Durability of response after controlled drug discontinuation could not be reasonably assessed, given the small sample size of patients who entered the discontinuation phase (n = 10). Fluoxetine was well tolerated, with no significant differences in discontinuation due to side effects between treatment groups. Fluoxetine is a moderately effective and well-tolerated treatment for hypochondriasis.

  16. Comparison of face masks in the bag-mask ventilation of a manikin.

    PubMed

    Redfern, D; Rassam, S; Stacey, M R; Mecklenburgh, J S

    2006-02-01

    We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.

  17. A schlieren optical study of the human cough with and without wearing masks for aerosol infection control

    PubMed Central

    Tang, Julian W.; Liebner, Thomas J.; Craven, Brent A.; Settles, Gary S.

    2009-01-01

    Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask). PMID:19815575

  18. A schlieren optical study of the human cough with and without wearing masks for aerosol infection control.

    PubMed

    Tang, Julian W; Liebner, Thomas J; Craven, Brent A; Settles, Gary S

    2009-12-06

    Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask).

  19. Rates of initial acceptance of PAP masks and outcomes of mask switching.

    PubMed

    Bachour, Adel; Vitikainen, Pirjo; Maasilta, Paula

    2016-05-01

    Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms. We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching. Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks. The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

  20. Robust source and mask optimization compensating for mask topography effects in computational lithography.

    PubMed

    Li, Jia; Lam, Edmund Y

    2014-04-21

    Mask topography effects need to be taken into consideration for a more accurate solution of source mask optimization (SMO) in advanced optical lithography. However, rigorous 3D mask models generally involve intensive computation and conventional SMO fails to manipulate the mask-induced undesired phase errors that degrade the usable depth of focus (uDOF) and process yield. In this work, an optimization approach incorporating pupil wavefront aberrations into SMO procedure is developed as an alternative to maximize the uDOF. We first design the pupil wavefront function by adding primary and secondary spherical aberrations through the coefficients of the Zernike polynomials, and then apply the conjugate gradient method to achieve an optimal source-mask pair under the condition of aberrated pupil. We also use a statistical model to determine the Zernike coefficients for the phase control and adjustment. Rigorous simulations of thick masks show that this approach provides compensation for mask topography effects by improving the pattern fidelity and increasing uDOF.

  1. Effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance

    NASA Astrophysics Data System (ADS)

    Dietze, Uwe; Dress, Peter; Waehler, Tobias; Singh, Sherjang; Jonckheere, Rik; Baudemprez, Bart

    2011-03-01

    Extreme Ultraviolet Lithography (EUVL) is considered the leading lithography technology choice for semiconductor devices at 16nm HP node and beyond. However, before EUV Lithography can enter into High Volume Manufacturing (HVM) of advanced semiconductor devices, the ability to guarantee mask integrity at point-of-exposure must be established. Highly efficient, damage free mask cleaning plays a critical role during the mask manufacturing cycle and throughout the life of the mask, where the absence of a pellicle to protect the EUV mask increases the risk of contamination during storage, handling and use. In this paper, we will present effective EUVL mask cleaning technology solutions for mask manufacturing and in-fab mask maintenance, which employs an intelligent, holistic approach to maximize Mean Time Between Cleans (MBTC) and extend the useful life span of the reticle. The data presented will demonstrate the protection of the capping and absorber layers, preservation of pattern integrity as well as optical and mechanical properties to avoid unpredictable CD-linewidth and overlay shifts. Experiments were performed on EUV blanks and pattern masks using various process conditions. Conditions showing high particle removal efficiency (PRE) and minimum surface layer impact were then selected for durability studies. Surface layer impact was evaluated over multiple cleaning cycles by means of UV reflectivity metrology XPS analysis and wafer prints. Experimental results were compared to computational models. Mask life time predictions where made using the same computational models. The paper will provide a generic overview of the cleaning sequence which yielded best results, but will also provide recommendations for an efficient in-fab mask maintenance scheme, addressing handling, storage, cleaning and inspection.

  2. Laser Doppler imaging of cutaneous blood flow through transparent face masks: a necessary preamble to computer-controlled rapid prototyping fabrication with submillimeter precision.

    PubMed

    Allely, Rebekah R; Van-Buendia, Lan B; Jeng, James C; White, Patricia; Wu, Jingshu; Niszczak, Jonathan; Jordan, Marion H

    2008-01-01

    A paradigm shift in management of postburn facial scarring is lurking "just beneath the waves" with the widespread availability of two recent technologies: precise three-dimensional scanning/digitizing of complex surfaces and computer-controlled rapid prototyping three-dimensional "printers". Laser Doppler imaging may be the sensible method to track the scar hyperemia that should form the basis of assessing progress and directing incremental changes in the digitized topographical face mask "prescription". The purpose of this study was to establish feasibility of detecting perfusion through transparent face masks using the Laser Doppler Imaging scanner. Laser Doppler images of perfusion were obtained at multiple facial regions on five uninjured staff members. Images were obtained without a mask, followed by images with a loose fitting mask with and without a silicone liner, and then with a tight fitting mask with and without a silicone liner. Right and left oblique images, in addition to the frontal images, were used to overcome unobtainable measurements at the extremes of face mask curvature. General linear model, mixed model, and t tests were used for data analysis. Three hundred seventy-five measurements were used for analysis, with a mean perfusion unit of 299 and pixel validity of 97%. The effect of face mask pressure with and without the silicone liner was readily quantified with significant changes in mean cutaneous blood flow (P < .5). High valid pixel rate laser Doppler imager flow data can be obtained through transparent face masks. Perfusion decreases with the application of pressure and with silicone. Every participant measured differently in perfusion units; however, consistent perfusion patterns in the face were observed.

  3. Self-masking: Listening during vocalization. Normal hearing.

    PubMed

    Borg, Erik; Bergkvist, Christina; Gustafsson, Dan

    2009-06-01

    What underlying mechanisms are involved in the ability to talk and listen simultaneously and what role does self-masking play under conditions of hearing impairment? The purpose of the present series of studies is to describe a technique for assessment of masked thresholds during vocalization, to describe normative data for males and females, and to focus on hearing impairment. The masking effect of vocalized [a:] on narrow-band noise pulses (250-8000 Hz) was studied using the maximum vocalization method. An amplitude-modulated series of sound pulses, which sounded like a steam engine, was masked until the criterion of halving the perceived pulse rate was reached. For masking of continuous reading, a just-follow-conversation criterion was applied. Intra-session test-retest reproducibility and inter-session variability were calculated. The results showed that female voices were more efficient in masking high frequency noise bursts than male voices and more efficient in masking both a male and a female test reading. The male had to vocalize 4 dBA louder than the female to produce the same masking effect on the test reading. It is concluded that the method is relatively simple to apply and has small intra-session and fair inter-session variability. Interesting gender differences were observed.

  4. Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2.

    PubMed

    Wood, Fiona E; Morley, Colin J; Dawson, Jennifer A; Kamlin, C Omar F; Owen, Louise S; Donath, Susan; Davis, Peter G

    2008-05-01

    Techniques of positioning and holding neonatal face masks vary. Studies have shown that leak at the face mask is common and often substantial irrespective of operator experience. (1) To identify a technique for face mask placement and hold which will minimise mask leak. (2) To investigate the effect of written instruction and demonstration of the identified technique on mask leak for two round face masks. Three experienced neonatologists compared methods of placing and holding face masks to minimise the leak for Fisher & Paykel 60 mm and Laerdal size 0/1 masks. 50 clinical staff gave positive pressure ventilation to a modified manikin designed to measure leak at the face mask. They were provided with written instructions on how to position and hold each mask and then received a demonstration. Face mask leak was measured after each teaching intervention. A technique of positioning and holding the face masks was identified which minimised leak. The mean (SD) mask leaks before instruction, after instruction and after demonstration were 55% (31), 49% (30), 33% (26) for the Laerdal mask and 57% (25), 47% (28), 32% (30) for the Fisher & Paykel mask. There was no significant difference in mask leak between the two masks. Written instruction alone reduced leak by 8.8% (CI 1.4% to 16.2%) for either mask; when combined with a demonstration mask leak was reduced by 24.1% (CI 16.4% to 31.8%). Written instruction and demonstration of the identified optimal technique resulted in significantly reduced face mask leak.

  5. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and

  6. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series

    PubMed Central

    Ng, Justin R.; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G.; Chai-Coetzer, Ching Li; McEvoy, R. Doug; Antic, Nick

    2016-01-01

    Study Objectives: The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. Methods: We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. Results: The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m2) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. Conclusions: If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Ng JR, Aiyappan V, Mercer J, Catcheside PG, Chai-Coetzer CL, McEvoy RD, Antic N. Choosing an oronasal mask to deliver continuous positive airway pressure may cause more upper airway obstruction or lead to higher continuous positive airway pressure requirements than a nasal

  7. Electroconvulsive therapy can benefit from controlled hyperventilation using a laryngeal mask.

    PubMed

    Haeck, Martina; Gillmann, Benjamin; Janouschek, Hildegard; Grözinger, Michael

    2011-11-01

    Hypocapnia through hyperventilation is a well-known procedure in electroconvulsive therapy (ECT) to enhance seizure activity. However, it has mostly been applied in an uncontrolled manner. Originally intended for a better management of the supraglottic airway, laryngeal masks are more suited to monitor levels of CO(2) during hyperventilation than face masks and thereby provide for the possibility of controlled hyperventilation (CHV). The impact of CHV was retrospectively studied in 114 consecutive patients; 65 of them had received ECT with CHV and 49 had received ECT with uncontrolled hyperventilation (UHV) directly prior to the time period when the laryneal mask was introduced to the ECT treatment procedure. The CO(2) level in the CHV group was aimed at 30 mmHg or below. CHV considerably enhanced the seizure activity leading to changes in clinically determined parameters of the treatment course: the necessity for increasing the electric charge, for re-stimulations (trend) and for bilateral stimulations was lower in the CHV group as compared to the UHV group. The improvement in the Global Assessment of Functioning Scores was not different in both groups. CHV was associated with a higher amount of prolonged seizures, with a reduced number of delirious symptoms after treatments and an attenuating effect on heart rate. Concluding, CHV can help to maintain the applied electric charge low without worsening the clinical outcome. Therefore, it is a helpful technical improvement. However, it should be used carefully with regard to prolonged seizures.

  8. Overlay improvement by exposure map based mask registration optimization

    NASA Astrophysics Data System (ADS)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density

  9. Polarization masks: concept and initial assessment

    NASA Astrophysics Data System (ADS)

    Lam, Michael; Neureuther, Andrew R.

    2002-07-01

    Polarization from photomasks can be used as a new lever to improve lithographic performance in both binary and phase-shifting masks (PSMs). While PSMs manipulate the phase of light to control the temporal addition of electric field vectors, polarization masks manipulate the vector direction of electric field vectors to control the spatial addition of electric field components. This paper explores the theoretical possibilities of polarization masks, showing that it is possible to use bar structures within openings on the mask itself to polarize incident radiation. Rigorous electromagnetic scattering simulations using TEMPEST and imaging with SPLAT are used to give an initial assessment on the functionality of polarization masks, discussing the polarization quality and throughputs achieved with the masks. Openings between 1/8 and 1/3 of a wavelength provide both a low polarization ratio and good transmission. A final overall throughput of 33% - 40% is achievable, corresponding to a dose hit of 2.5x - 3x.

  10. Mask_explorer: A tool for exploring brain masks in fMRI group analysis.

    PubMed

    Gajdoš, Martin; Mikl, Michal; Mareček, Radek

    2016-10-01

    Functional magnetic resonance imaging (fMRI) studies of the human brain are appearing in increasing numbers, providing interesting information about this complex system. Unique information about healthy and diseased brains is inferred using many types of experiments and analyses. In order to obtain reliable information, it is necessary to conduct consistent experiments with large samples of subjects and to involve statistical methods to confirm or reject any tested hypotheses. Group analysis is performed for all voxels within a group mask, i.e. a common space where all of the involved subjects contribute information. To our knowledge, a user-friendly interface with the ability to visualize subject-specific details in a common analysis space did not yet exist. The purpose of our work is to develop and present such interface. Several pitfalls have to be avoided while preparing fMRI data for group analysis. One such pitfall is spurious non-detection, caused by inferring conclusions in the volume of a group mask that has been corrupted due to a preprocessing failure. We describe a MATLAB toolbox, called the mask_explorer, designed for prevention of this pitfall. The mask_explorer uses a graphical user interface, enables a user-friendly exploration of subject masks and is freely available. It is able to compute subject masks from raw data and create lists of subjects with potentially problematic data. It runs under MATLAB with the widely used SPM toolbox. Moreover, we present several practical examples where the mask_explorer is usefully applied. The mask_explorer is designed to quickly control the quality of the group fMRI analysis volume and to identify specific failures related to preprocessing steps and acquisition. It helps researchers detect subjects with potentially problematic data and consequently enables inspection of the data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Imaging Protoplanets: Observing Transition Disks with Non-Redundant Masking

    NASA Astrophysics Data System (ADS)

    Sallum, Stephanie

    2017-01-01

    Transition disks - protoplanetary disks with inner, solar system sized clearings - may be shaped by young planets. Directly imaging protoplanets in these objects requires high contrast and resolution, making them promising targets for future extremely large telescopes. The interferometric technique of non-redundant masking (NRM) is well suited for these observations, enabling companion detection for contrasts of 1:100 - 1:1000 at or within the diffraction limit. My dissertation focuses on searching for and characterizing companions in transition disk clearings using NRM. I will briefly describe the technique and present spatially resolved observations of the T Cha and LkCa 15 transition disks. Both of these objects hosted posited substellar companions. However multi-epoch T Cha datasets cannot be explained by planets orbiting in the disk plane. Conversely, LkCa 15 data taken with the Large Binocular Telescope (LBT) in single-aperture mode reveal the presence of multiple forming planets. The dual aperture LBT will provide triple the angular resolution of these observations, dramatically increasing the phase space for exoplanet detection. I will also present new results from the dual-aperture LBT, with similar resolution to that expected for next generation facilities like GMT.

  12. Current status of x-ray mask manufacturing at the Microlithographic Mask Development Center

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hughes, Patrick J.

    1996-07-01

    The Microlithographic Mask Development Center (MMD) has been the focal point of X-ray mask development efforts in the United States since its inception in 1993. Funded by the Advanced Research Projects Agency (ARPA), and with technical support from the Proximity X-ray Lithography Association (AT&T, IBM, Loral Federal Systems, and Motorola) the MMD has recently made dramatic advances in mask fabrication. Numerous defect-free 64Mb and 256Mb DRAM masks have been made on both boron-doped silicon and silicon carbide substrates. Image-placement error of less than 35nm 3 sigma is achieved with high yield. Image-size (critical dimension) control of 25nm 3 sigma on 250nm nominal images is representative performance. This progress is being made in a manufacturing environment with significant volumes, multiple customers, multiple substrate configurations, and fast turnaround-time (TAT) requirements. The MMD state-of-the-art equipment infrastructure has made much of this progress possible. This year the MMD qualified the EL-4, an IBM-designed-and-built variable-shaped-spot e-beam system. The fundamental performance parameters of this system will be described. Operational techniques of multiple partial exposure writing and product specific emulation (PSE) have been implemented to improve image-placement accuracy with remarkable success. Image-size control was studied in detail with contributory components separated. Defect density was systematically reduced to yield defect-free masks while simultaneously tightening inspection criteria. Information about these and other recent engineering highlights will be reported. An outline of the primary engineering challenges and goals for 1996 and status of progress toward 100 nm design rule capability will also be given.

  13. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    PubMed

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Modeling and Observations of Phase-Mask Trapezoidal Profiles with Grating-Fiber Image Reproduction

    NASA Technical Reports Server (NTRS)

    Lyons, Donald R.; Lindesay, James V.; Lee, Hyung R.; Ndlela, Zolili U.; Thompso, Erica J.

    2000-01-01

    We report on an investigation of the trapezoidal design and fabrication defects in phase masks used to produce Bragg reflection gratings in optical fibers. We used a direct visualization technique to examine the nonuniformity of the interference patterns generated by several phase masks. Fringe patterns from the phase masks are compared with the analogous patterns resulting from two-beam interference. Atomic force microscope imaging of the actual phase gratings that give rise to anomalous fringe patterns is used to determine input parameters for a general theoretical model. Phase masks with pitches of 0.566 and 1.059 microns are modeled and investigated.

  15. Model-based virtual VSB mask writer verification for efficient mask error checking and optimization prior to MDP

    NASA Astrophysics Data System (ADS)

    Pack, Robert C.; Standiford, Keith; Lukanc, Todd; Ning, Guo Xiang; Verma, Piyush; Batarseh, Fadi; Chua, Gek Soon; Fujimura, Akira; Pang, Linyong

    2014-10-01

    A methodology is described wherein a calibrated model-based `Virtual' Variable Shaped Beam (VSB) mask writer process simulator is used to accurately verify complex Optical Proximity Correction (OPC) and Inverse Lithography Technology (ILT) mask designs prior to Mask Data Preparation (MDP) and mask fabrication. This type of verification addresses physical effects which occur in mask writing that may impact lithographic printing fidelity and variability. The work described here is motivated by requirements for extreme accuracy and control of variations for today's most demanding IC products. These extreme demands necessitate careful and detailed analysis of all potential sources of uncompensated error or variation and extreme control of these at each stage of the integrated OPC/ MDP/ Mask/ silicon lithography flow. The important potential sources of variation we focus on here originate on the basis of VSB mask writer physics and other errors inherent in the mask writing process. The deposited electron beam dose distribution may be examined in a manner similar to optical lithography aerial image analysis and image edge log-slope analysis. This approach enables one to catch, grade, and mitigate problems early and thus reduce the likelihood for costly long-loop iterations between OPC, MDP, and wafer fabrication flows. It moreover describes how to detect regions of a layout or mask where hotspots may occur or where the robustness to intrinsic variations may be improved by modification to the OPC, choice of mask technology, or by judicious design of VSB shots and dose assignment.

  16. Psychometric functions for informational masking

    NASA Astrophysics Data System (ADS)

    Lutfi, Robert A.; Kistler, Doris J.; Callahan, Michael R.; Wightman, Frederic L.

    2003-12-01

    The term informational masking has traditionally been used to refer to elevations in signal threshold resulting from masker uncertainty. In the present study, the method of constant stimuli was used to obtain complete psychometric functions (PFs) from 44 normal-hearing listeners in conditions known to produce varying amounts of informational masking. The listener's task was to detect a pure-tone signal in the presence of a broadband noise masker (low masker uncertainty) and in the presence of multitone maskers with frequencies and amplitudes that varied at random from one presentation to the next (high masker uncertainty). Relative to the broadband noise condition, significant reductions were observed in both the slope and the upper asymptote of the PF for multitone maskers producing large amounts of informational masking. Slope was affected more for some listeners and conditions while asymptote was affected more for others; consequently, neither parameter alone was highly predictive of individual thresholds or the amount of informational masking. Mean slopes and asymptotes varied nonmonotonically with the number of masker components in a manner similar to mean thresholds, particularly when the estimated effect of energetic masking on thresholds was subtracted out. As in past studies, the threshold data were well described by a model in which trial-by-trial judgments are based on a weighted sum of levels in dB at the output of independent auditory filters. The psychometric data, however, complicated the model's interpretation in two ways: First, they suggested that, depending on the listener and condition, the weights can either reflect a fixed influence of masker components on each trial or the effect of occasionally mistaking a masker component for the signal from trial to trial. Second, they indicated that in either case the variance of the underlying decision variable as estimated from PF slope is not by itself great enough to account for the observed changes

  17. Masking Period Patterns & Forward Masking for Speech-Shaped Noise: Age-related effects

    PubMed Central

    Grose, John H.; Menezes, Denise C.; Porter, Heather L.; Griz, Silvana

    2015-01-01

    Objective The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to non-simultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Design Participants included younger (n = 11), middle-aged (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions, and assessed how well the temporal window fits accounted for these data. Results The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. Conclusions This study demonstrated an age-related increase in susceptibility to non-simultaneous masking, supporting the hypothesis that exacerbated non-simultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data suggesting an association between susceptibility to forward masking and speech understanding in modulated noise. PMID:26230495

  18. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea.

    PubMed

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A; Landry, Shane; Mansfield, Darren R; Hamilton, Garun S

    2016-09-15

    Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10-15.5) cm H2O compared to nasal pillow masks, 11 (8-12.5) cm H2O and nasal masks, 10 (8-12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R(2) = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5-8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  19. Dynamics of normalization underlying masking in human visual cortex.

    PubMed

    Tsai, Jeffrey J; Wade, Alex R; Norcia, Anthony M

    2012-02-22

    Stimulus visibility can be reduced by other stimuli that overlap the same region of visual space, a process known as masking. Here we studied the neural mechanisms of masking in humans using source-imaged steady state visual evoked potentials and frequency-domain analysis over a wide range of relative stimulus strengths of test and mask stimuli. Test and mask stimuli were tagged with distinct temporal frequencies and we quantified spectral response components associated with the individual stimuli (self terms) and responses due to interaction between stimuli (intermodulation terms). In early visual cortex, masking alters the self terms in a manner consistent with a reduction of input contrast. We also identify a novel signature of masking: a robust intermodulation term that peaks when the test and mask stimuli have equal contrast and disappears when they are widely different. We fit all of our data simultaneously with family of a divisive gain control models that differed only in their dynamics. Models with either very short or very long temporal integration constants for the gain pool performed worse than a model with an integration time of ∼30 ms. Finally, the absolute magnitudes of the response were controlled by the ratio of the stimulus contrasts, not their absolute values. This contrast-contrast invariance suggests that many neurons in early visual cortex code relative rather than absolute contrast. Together, these results provide a more complete description of masking within the normalization framework of contrast gain control and suggest that contrast normalization accomplishes multiple functional goals.

  20. Shadows Alter Facial Expressions of Noh Masks

    PubMed Central

    Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo

    2013-01-01

    Background A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers’ recognition of the emotional expressions. Methodology/Principal Findings In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Conclusions/Significance Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa’s smile. They also agree with the aesthetic principle of Japanese traditional art “yugen (profound grace and subtlety)”, which highly appreciates subtle emotional expressions in the darkness. PMID:23940748

  1. Assessment of molecular contamination in mask pod

    NASA Astrophysics Data System (ADS)

    Foray, Jean Marie; Dejaune, Patrice; Sergent, Pierre; Gough, Stuart; Cheung, D.; Davenet, Magali; Favre, Arnaud; Rude, C.; Trautmann, T.; Tissier, Michel; Fontaine, H.; Veillerot, M.; Avary, K.; Hollein, I.; Lerit, R.

    2008-04-01

    contaminants: by inline techniques based on Adixen humidity, also VOC and organic sensors, together by off-line techniques already used in the extensive previous mask pods benchmark (TD-GCMS & Ionic Chromatography). Humidity and VOC levels from mask carriers had shown significant reduction after Adixen pod conditioning process. Focus had been made on optimized vacuum step (for AMC) after particles carrier cleaning cycle. Based upon these key results new procedures, as well as guidelines for mask carrier cleaning optimization are proposed to improve pod contamination control. Summary results/next steps: This paper reports molecular contamination measurement campaigns performed by a pool of European partners along the mask supply chain. It allows us to investigate, identify and quantify critical molecular contamination in mask pod, as well as VOC and humidity, issues depending on locations, uses, and carrier's type. Preliminary studies highlight initial process solutions for pods conditioning that are being used for short term industrialization and further industrialized.

  2. Masking with faces in central visual field under a variety of temporal schedules.

    PubMed

    Daar, Marwan; Wilson, Hugh R

    2015-11-01

    With a few exceptions, previous studies have explored masking using either a backward mask or a common onset trailing mask, but not both. In a series of experiments, we demonstrate the use of faces in central visual field as a viable method to study the relationship between these two types of mask schedule. We tested observers in a two alternative forced choice face identification task, where both target and mask comprised synthetic faces, and show that a simple model can successfully predict masking across a variety of masking schedules ranging from a backward mask to a common onset trailing mask and a number of intermediate variations. Our data are well accounted for by a window of sensitivity to mask interference that is centered at around 100 ms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Masking Period Patterns and Forward Masking for Speech-Shaped Noise: Age-Related Effects.

    PubMed

    Grose, John H; Menezes, Denise C; Porter, Heather L; Griz, Silvana

    2016-01-01

    The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to nonsimultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Participants included younger (n = 11), middle-age (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions and assessed how well the temporal window fits accounted for these data. The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. This study demonstrated an age-related increase in susceptibility to nonsimultaneous masking, supporting the hypothesis that exacerbated nonsimultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data, suggesting an association between susceptibility to forward masking and speech understanding in modulated noise.

  4. Attentional capture by masked colour singletons.

    PubMed

    Ansorge, Ulrich; Horstmann, Gernot; Worschech, Franziska

    2010-09-15

    We tested under which conditions a colour singleton of which an observer is unaware captures attention. To prevent visual awareness of the colour singleton, we used backward masking. We find that a masked colour singleton cue captures attention if it matches the observer's goal to search for target colours but not if it is task-irrelevant. This is also reflected in event-related potentials to the visible target: the masked goal-matching cue elicits an attentional potential (N2pc) in a target search task. By contrast, a non-matching but equally strong masked colour singleton cue failed to elicit a capture effect and an N2pc. Results are discussed with regard to currently pertaining conceptions of attentional capture by colour singletons. Copyright 2010 Elsevier Ltd. All rights reserved.

  5. A pilot study on the use of geometrically accurate face models to replicate ex vivo N95 mask fit.

    PubMed

    Golshahi, Laleh; Telidetzki, Karla; King, Ben; Shaw, Diana; Finlay, Warren H

    2013-01-01

    To test the feasibility of replicating a face mask seal in vitro, we created 5 geometrically accurate reconstructions of the head and neck of an adult human subject using different materials. Three breathing patterns were simulated with each replica and an attached N95 mask. Quantitative fit testing on the subject and the replicas showed that none of the 5 isotropic materials used allowed duplication of the ex vivo mask seal for the specific mask-face combination studied. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  6. New mask technology challenges

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.

    2001-09-01

    Mask technology development has accelerated dramatically in recent years from the glacial pace of the last three decades to the rapid and sometimes simultaneous introductions of new wavelengths and mask-based resolution enhancement techniques. The nature of the semiconductor business has also become one driven by time-to-market as an overwhelming factor in capturing market share and profit. These are among the factors that have created enormous stress on the mask industry to produce masks with enhanced capabilities, such as phase-shifting attenuators, sub-resolution assist bars, and optical proximity correction (OPC) features, while maintaining or reducing cost and cycle time. The mask can no longer be considered a commodity item that is purchased form the lowest-cost supplier. Instead, it must now be promoted as an integral part of the technical and business case for a total lithographic solution. Improving partnership between designer, mask-maker, and wafer lithographer will be the harbinger of success in finding a profitable balance of capability, cost, and cycle time. Likewise for equipment infrastructure development, stronger partnership on the international level is necessary to control development cost and mitigate schedule and technical risks.

  7. Are Masking-Based Models of Risk Useful?

    PubMed

    Gisiner, Robert C

    2016-01-01

    As our understanding of directly observable effects from anthropogenic sound exposure has improved, concern about "unobservable" effects such as stress and masking have received greater attention. Equal energy models of masking such as power spectrum models have the appeal of simplicity, but do they offer biologically realistic assessments of the risk of masking? Data relevant to masking such as critical ratios, critical bandwidths, temporal resolution, and directional resolution along with what is known about general mammalian antimasking mechanisms all argue for a much more complicated view of masking when making decisions about the risk of masking inherent in a given anthropogenic sound exposure scenario.

  8. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series.

    PubMed

    Ng, Justin R; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G; Chai-Coetzer, Ching Li; McEvoy, R Doug; Antic, Nick

    2016-09-15

    The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m(2)) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  9. Forward-masking based gain control in odontocete biosonar: an evoked-potential study.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2009-04-01

    Auditory evoked potentials (AEPs) were recorded during echolocation in a false killer whale Pseudorca crassidens. An electronically synthesized and played-back ("phantom") echo was used. Each electronic echo was triggered by an emitted biosonar pulse. The echo had a spectrum similar to that of the emitted biosonar clicks, and its intensity was proportional to that of the emitted click. The attenuation of the echo relative to the emitted click and its delay was controlled by the experimenter. Four combinations of echo attenuation and delay were tested (-31 dB, 2 ms), (-40 dB, 4 ms), (-49 dB, 8 ms), and (-58 dB, 16 ms); thus, attenuation and delay were associated with a rate of 9 dB of increased attenuation per delay doubling. AEPs related to emitted clicks displayed a regular amplitude dependence on the click level. Echo-related AEPs did not feature amplitude dependence on echo attenuation or emitted click levels, except in a few combinations of the lowest values of these two variables. The results are explained by a hypothesis that partial forward masking of the echoes by the preceding emitted sonar pulses serves as a kind of automatic gain control in the auditory system of echolocating odontocetes.

  10. Masking as an effective quality control method for next-generation sequencing data analysis.

    PubMed

    Yun, Sajung; Yun, Sijung

    2014-12-13

    Next generation sequencing produces base calls with low quality scores that can affect the accuracy of identifying simple nucleotide variation calls, including single nucleotide polymorphisms and small insertions and deletions. Here we compare the effectiveness of two data preprocessing methods, masking and trimming, and the accuracy of simple nucleotide variation calls on whole-genome sequence data from Caenorhabditis elegans. Masking substitutes low quality base calls with 'N's (undetermined bases), whereas trimming removes low quality bases that results in a shorter read lengths. We demonstrate that masking is more effective than trimming in reducing the false-positive rate in single nucleotide polymorphism (SNP) calling. However, both of the preprocessing methods did not affect the false-negative rate in SNP calling with statistical significance compared to the data analysis without preprocessing. False-positive rate and false-negative rate for small insertions and deletions did not show differences between masking and trimming. We recommend masking over trimming as a more effective preprocessing method for next generation sequencing data analysis since masking reduces the false-positive rate in SNP calling without sacrificing the false-negative rate although trimming is more commonly used currently in the field. The perl script for masking is available at http://code.google.com/p/subn/. The sequencing data used in the study were deposited in the Sequence Read Archive (SRX450968 and SRX451773).

  11. Jig Aligns Shadow Mask On CCD

    NASA Technical Reports Server (NTRS)

    Matus, Carlos V.

    1989-01-01

    Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.

  12. Use of face masks by non-scrubbed operating room staff: a randomized controlled trial.

    PubMed

    Webster, Joan; Croger, Sarah; Lister, Carolyn; Doidge, Michelle; Terry, Michael J; Jones, Ian

    2010-03-01

    Ambiguity remains about the effectiveness of wearing surgical face masks. The purpose of this study was to assess the impact on surgical site infections (SSIs) when non-scrubbed operating room staff did not wear surgical face masks. Eight hundred twenty-seven participants undergoing elective or emergency obstetric, gynecological, general, orthopaedic, breast or urological surgery in an Australian tertiary hospital were enrolled. Complete follow-up data were available for 811 patients (98.1%). Operating room lists were randomly allocated to a 'Mask group' (all non-scrubbed staff wore a mask) or 'No Mask group' (none of the non-scrubbed staff wore masks). The primary end point, SSI was identified using in-patient surveillance; post discharge follow-up and chart reviews. The patient was followed for up to six weeks. Overall, 83 (10.2%) surgical site infections were recorded; 46/401 (11.5%) in the Masked group and 37/410 (9.0%) in the No Mask group; odds ratio (OR) 0.77 (95% confidence interval (CI) 0.49 to 1.21), p = 0.151. Independent risk factors for surgical site infection included: any pre-operative stay (adjusted odds ratio [aOR], 0.43 (95% CI, 0.20; 0.95), high BMI aOR, 0.38 (95% CI, 0.17; 0.87), and any previous surgical site infection aOR, 0.40 (95% CI, 0.17; 0.89). Surgical site infection rates did not increase when non-scrubbed operating room personnel did not wear a face mask.

  13. Effectiveness of activated carbon masks in preventing anticancer drug inhalation.

    PubMed

    Sato, Junya; Kogure, Atushi; Kudo, Kenzo

    2016-01-01

    The exposure of healthcare workers to anticancer drugs such as cyclophosphamide (CPA) is a serious health concern. Anticancer drug pollution may spread outside biological safety cabinets even when a closed system is used. The inhalation of vaporized anticancer drugs is thought to be the primary route of exposure. Therefore, it is important that healthcare workers wear masks to prevent inhalation of anticancer drugs. However, the permeability of medical masks to vaporized anticancer drugs has not been examined. Furthermore, the performance differences between masks including activated carbon with chemical adsorptivity and non-activated carbon masks are uncertain. We investigated activated carbon mask permeability to vaporized CPA, and assessed whether inhibition of vaporized CPA permeability was attributable to the masks' adsorption abilities. A CPA solution (4 mg) was vaporized in a chamber and passed through three types of masks: Pleated-type cotton mask (PCM), pleated-type activated carbon mask (PAM), and stereoscopic-type activated carbon mask (SAM); the flow rate was 1.0 L/min for 1 h. The air was then recovered in 50 % ethanol. CPA quantities in the solution were determined by liquid chromatography time-of-flight mass spectrometry. To determine CPA adsorption by the mask, 5 cm 2 of each mask was immersed in 10 mL of CPA solution (50-2500 μg/mL) for 1 h. CPA concentrations were measured by high-performance liquid chromatography with ultraviolet detection. For the control (no mask), 3.735 ± 0.543 μg of CPA was recovered from the aerated solution. Significantly lower quantities were recovered from PCM (0.538 ± 0.098 μg) and PAM (0.236 ± 0.193 μg) ( p  < 0.001 and p  < 0.001 vs control, respectively). CPA quantities recovered from all of SAM samples were below the quantification limit. When a piece of the SAM was immersed in the CPA solution, a marked decrease to less than 3.1 % of the initial CPA concentration was observed

  14. The automatic back-check mechanism of mask tooling database and automatic transmission of mask tooling data

    NASA Astrophysics Data System (ADS)

    Xu, Zhe; Peng, M. G.; Tu, Lin Hsin; Lee, Cedric; Lin, J. K.; Jan, Jian Feng; Yin, Alb; Wang, Pei

    2006-10-01

    Nowadays, most foundries have paid more and more attention in order to reduce the CD width. Although the lithography technologies have developed drastically, mask data accuracy is still a big challenge than before. Besides, mask (reticle) price also goes up drastically such that data accuracy needs more special treatments.We've developed a system called eFDMS to guarantee the mask data accuracy. EFDMS is developed to do the automatic back-check of mask tooling database and the data transmission of mask tooling. We integrate our own EFDMS systems to engage with the standard mask tooling system K2 so that the upriver and the downriver processes of the mask tooling main body K2 can perform smoothly and correctly with anticipation. The competition in IC marketplace is changing from high-tech process to lower-price gradually. How to control the reduction of the products' cost more plays a significant role in foundries. Before the violent competition's drawing nearer, we should prepare the cost task ahead of time.

  15. Effect of Ibuprofen on masking endodontic diagnosis.

    PubMed

    Read, Jason K; McClanahan, Scott B; Khan, Asma A; Lunos, Scott; Bowles, Walter R

    2014-08-01

    An accurate diagnosis is of upmost importance before initiating endodontic treatment; yet, there are occasions when the practitioner cannot reproduce the patient's chief complaint because the patient has become asymptomatic. Ibuprofen taken beforehand may "mask" or eliminate the patient's symptoms. In fact, 64%-83% of patients with dental pain take analgesics before seeing a dentist. The purpose of this study was to examine the possible "masking" effect of ibuprofen on endodontic diagnostic tests. Forty-two patients with endodontic pain underwent testing (cold, percussion, palpation, and bite force measurement) and then received either placebo or 800 mg ibuprofen. Both patients and operators were blinded to the medication received. One hour later, diagnostic testing was repeated and compared with pretreatment testing. Ibuprofen affected testing values for vital teeth by masking palpation 40%, percussion 25%, and cold 25% on affected teeth with symptomatic irreversible pulpitis and symptomatic apical periodontitis. There was no observed masking effect in the placebo group on palpation, percussion, or cold values. When nonvital teeth were included, the masking effect of ibuprofen was decreased. However, little masking occurred with the bite force measurement differences. Analgesics taken before the dental appointment can affect endodontic diagnostic testing results. Bite force measurements can assist in identifying the offending tooth in cases in which analgesics "mask" the endodontic diagnosis. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. The technical consideration of multi-beam mask writer for production

    NASA Astrophysics Data System (ADS)

    Lee, Sang Hee; Ahn, Byung-Sup; Choi, Jin; Shin, In Kyun; Tamamushi, Shuichi; Jeon, Chan-Uk

    2016-10-01

    Multi-beam mask writer is under development to solve the throughput and patterning resolution problems in VSB mask writer. Theoretically, the writing time is appropriate for future design node and the resolution is improved with multi-beam mask writer. Many previous studies show the feasible results of resolution, CD control and registration. Although such technical results of development tool seem to be enough for mass production, there are still many unexpected problems for real mass production. In this report, the technical challenges of multi-beam mask writer are discussed in terms of production and application. The problems and issues are defined based on the performance of current development tool compared with the requirements of mask quality. Using the simulation and experiment, we analyze the specific characteristics of electron beam in multi-beam mask writer scheme. Consequently, we suggest necessary specifications for mass production with multi-beam mask writer in the future.

  17. Comparison of Ventilation With One-Handed Mask Seal With an Intraoral Mask Versus Conventional Cuffed Face Mask in a Cadaver Model: A Randomized Crossover Trial.

    PubMed

    Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D

    2017-01-01

    We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; P<.001). The intraoral mask resulted in greater received minute volume received compared with conventional cuffed face mask during ventilation with a 1-handed mask seal in a cadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  18. A Prospective, Randomized, Masked, Placebo-Controlled Clinical Study of Capromorelin in Dogs with Reduced Appetite.

    PubMed

    Zollers, B; Wofford, J A; Heinen, E; Huebner, M; Rhodes, L

    2016-11-01

    Reduced appetite is a common clinical sign in dogs. This study evaluated the effectiveness and safety of capromorelin oral solution, (ENTYCE ® , Aratana Therapeutics, Leawood, KS) a new drug that is a ghrelin receptor agonist, for stimulation of appetite in dogs with reduced appetite. Capromorelin will increase appetite, as measured by the owner's evaluation, over 4 days. An additional objective was to evaluate the safety of capromorelin at the labeled dose. A total of 244 client-owned dogs reported by owners to be inappetent for at least 2 days were enrolled, with 177 cases in the effectiveness analysis. In this prospective, randomized, masked, placebo-controlled study, dogs were treated daily with capromorelin (3 mg/kg) oral solution (n = 121) or placebo oral solution (n = 56). Owners completed an evaluation of appetite at days 0 and 3 ± 1. Success was defined as improvement in appetite at day 3. Safety was evaluated by physical examination, clinical pathology, and monitoring adverse events and owner observations. Capromorelin treatment improved appetite compared to placebo (68.6% and 44.6% treatment successes with 95% CI 59.7, 76.3 and 32.2, 57.8, respectively, P = .008). Mean body weight in capromorelin-treated dogs increased compared to placebo-treated dogs (1.8% with 95% CI 1.3, 2.3, and 0.1% with 95% CI 0.9, 1.1, respectively, P < .001). Adverse reactions occurring in >5% of either group were diarrhea and vomiting. Capromorelin oral solution is an effective treatment for stimulation of appetite in dogs and represents the first ghrelin receptor agonist shown to be effective for this indication. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  19. Masked Hypertension and Incident Clinic Hypertension Among Blacks in the Jackson Heart Study.

    PubMed

    Abdalla, Marwah; Booth, John N; Seals, Samantha R; Spruill, Tanya M; Viera, Anthony J; Diaz, Keith M; Sims, Mario; Muntner, Paul; Shimbo, Daichi

    2016-07-01

    Masked hypertension, defined as nonelevated clinic blood pressure (BP) and elevated out-of-clinic BP may be an intermediary stage in the progression from normotension to hypertension. We examined the associations of out-of-clinic BP and masked hypertension using ambulatory BP monitoring with incident clinic hypertension in the Jackson Heart Study, a prospective cohort of blacks. Analyses included 317 participants with clinic BP <140/90 mm Hg, complete ambulatory BP monitoring, who were not taking antihypertensive medication at baseline in 2000 to 2004. Masked daytime hypertension was defined as mean daytime blood pressure ≥135/85 mm Hg, masked night-time hypertension as mean night-time BP ≥120/70 mm Hg, and masked 24-hour hypertension as mean 24-hour BP ≥130/80 mm Hg. Incident clinic hypertension, assessed at study visits in 2005 to 2008 and 2009 to 2012, was defined as the first visit with clinic systolic/diastolic BP ≥140/90 mm Hg or antihypertensive medication use. During a median follow-up of 8.1 years, there were 187 (59.0%) incident cases of clinic hypertension. Clinic hypertension developed in 79.2% and 42.2% of participants with and without any masked hypertension, 85.7% and 50.4% with and without masked daytime hypertension, 79.9% and 43.7% with and without masked night-time hypertension, and 85.7% and 48.2% with and without masked 24-hour hypertension, respectively. Multivariable-adjusted hazard ratios (95% confidence interval) of incident clinic hypertension for any masked hypertension and masked daytime, night-time, and 24-hour hypertension were 2.13 (1.51-3.02), 1.79 (1.24-2.60), 2.22 (1.58-3.12), and 1.91 (1.32-2.75), respectively. These findings suggest that ambulatory BP monitoring can identify blacks at increased risk for developing clinic hypertension. © 2016 American Heart Association, Inc.

  20. Scatterometry on pelliclized masks: an option for wafer fabs

    NASA Astrophysics Data System (ADS)

    Gallagher, Emily; Benson, Craig; Higuchi, Masaru; Okumoto, Yasuhiro; Kwon, Michael; Yedur, Sanjay; Li, Shifang; Lee, Sangbong; Tabet, Milad

    2007-03-01

    Optical scatterometry-based metrology is now widely used in wafer fabs for lithography, etch, and CMP applications. This acceptance of a new metrology method occurred despite the abundance of wellestablished CD-SEM and AFM methods. It was driven by the desire to make measurements faster and with a lower cost of ownership. Over the last year, scatterometry has also been introduced in advanced mask shops for mask measurements. Binary and phase shift masks have been successfully measured at all desired points during photomask production before the pellicle is mounted. There is a significant benefit to measuring masks with the pellicle in place. From the wafer fab's perspective, through-pellicle metrology would verify mask effects on the same features that are characterized on wafer. On-site mask verification would enable quality control and trouble-shooting without returning the mask to a mask house. Another potential application is monitoring changes to mask films once the mask has been delivered to the fab (haze, oxide growth, etc.). Similar opportunities apply to the mask metrologist receiving line returns from a wafer fab. The ability to make line-return measurements without risking defect introduction is clearly attractive. This paper will evaluate the feasibility of collecting scatterometry data on pelliclized masks. We explore the effects of several different pellicle types on scatterometry measurements made with broadband light in the range of 320-780 nm. The complexity introduced by the pellicles' optical behavior will be studied.

  1. Increased masked hypertension prevalence in patients with obesity.

    PubMed

    Özkan, Selçuk; Ata, Naim; Yavuz, Bunyamin

    2018-02-08

    Masked hypertension is associated with an increased risk for cardiovascular conditions. The aim of the study was to evaluate the relationship obesity parameters, including body weight, waist circumference, and body mass index. The study group consisted of 251 consecutive outpatient subjects without overt hypertension. Subjects were classified according to BMI. After a complete medical history and laboratory examination, patients' height, weight, waist circumference heart rate, and office blood pressure were recorded. All subjects underwent ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of Masked hypertension was significantly higher in patients with obesity than controls (30.9% vs 5.7%, p < 0.001). Body mass index (33.2 ± 4.3 vs 25.1 ± 2.7 p < 0.001), waist circumference (98.5 ± 11.7 vs 86.8 ± 8.8, p < 0.001), and weight (86.5 ± 11.8 vs. 69 ± 9.1, p < 0.001) in patients with obesity were significantly higher than in patients with normal weight. Office Systolic BP (121.8 ± 4.4 vs 120.5 ± 4.78, p = 0.035), ambulatory daytime systolic BP (128.8 ± 8.9 vs 124.5 ± 7.4, p < 0.001), ambulatory daytime diastolic BP (73.9 ± 9.5 vs 71.5 ± 7.0, p = 0.019), ambulatory night-time systolic BP in patients with obesity was significantly higher than in patients with normal weight. This study demonstrated that masked hypertension prevalence is higher in patients with obesity than control patients. It can be suggested that predefining obesity might be helpful in early detection of masked hypertension.

  2. High-sensitivity x-ray mask damage studies employing holographic gratings and phase-shifting interferometry

    NASA Astrophysics Data System (ADS)

    Hansen, Matthew E.; Cerrina, Franco

    1994-05-01

    A high-sensitivity holographic and interferometric metrology developed at the Center for X- ray Lithography (CXrL) has been employed to investigate in-plane distortions (IPD) produced in x-ray mask materials. This metrology has been applied to characterize damage to x-ray mask materials exposed to synchrotron radiation. X-ray mask damage and accelerated mask damage studies on silicon nitride and silicon carbide were conducted on the Aladdin ES-1 and ES-2 beamline exposure stations, respectively. Accumulated in-plane distortions due to x-ray irradiation were extracted from the incremental interferometric phase maps to yield IPD vs. dose curves for silicon nitride mask blanks. Silicon carbide mask blanks were subjected to accelerated mask damage in the high flux 2 mm X 2 mm beam of the ES-2 exposure station. An accelerated damage study of silicon carbide has shown no in-plane distortion for an accumulated dose of 800 kJ/cm2 with a measurement sensitivity of less than 5 nm.

  3. Masks For Deposition Of Aspherical Optical Surfaces

    NASA Technical Reports Server (NTRS)

    Rogers, John R.; Martin, John D.

    1992-01-01

    Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.

  4. Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.

    PubMed

    Deindl, Philipp; O'Reilly, Megan; Zoller, Katharina; Berger, Angelika; Pollak, Arnold; Schwindt, Jens; Schmölzer, Georg M

    2014-01-01

    Anatomical face mask with an air cushion rim might be placed accidentally in a false orientation on the newborn's face or filled with various amounts of air during neonatal resuscitation. Both false orientation as well as variable filling may reduce a tight seal and therefore hamper effective positive pressure ventilation (PPV). We aimed to measure the influence of mask type and mask position on the effectiveness of PPV. Twenty neonatal staff members delivered PPV to a modified, leak-free manikin. Resuscitation parameters were recorded using a self-inflatable bag PPV with an Intersurgical anatomical air cushion rim face mask (IS) and a size 0/1 Laerdal round face mask. Three different positions of the IS were tested: correct position, 90° and 180° rotation in reference to the midline of the face. IS masks in each correct position on the face but with different inflation of the air cushion (empty, 10, 20 and 30 mL). Mask leak was similar with mask rotation to either 90° or 180° but significantly increased from 27 (13-73) % with an adequate filled IS mask compared to 52 (16-83) % with an emptied air cushion rim. Anatomical-shaped face mask had similar mask leaks compared to round face mask. A wrongly positioned anatomical-shaped mask does not influence mask leak. Mask leak significantly increased once the air cushion rim was empty, which may cause failure in mask PPV.

  5. Is Suppression Just Normal Dichoptic Masking? Suprathreshold Considerations.

    PubMed

    Reynaud, Alexandre; Hess, Robert F

    2016-10-01

    Amblyopic patients have a deficit in visual acuity and contrast sensitivity in their amblyopic eye as well as suppression of the amblyopic eye input under binocular viewing conditions. In this study we wanted to assess the origin of the amblyopic suppression by studying the contrast perception of the amblyopic eye at suprathreshold levels under binocular and monocular viewing. Using a suprathreshold contrast matching task in which the reference and target stimuli were presented to different eyes either simultaneously or successively, we measured interocular contrast matching in 10 controls and 11 amblyopes (mean age 35 ± 15; 5 strabismics; 3 anisometropes; 3 mixed). This was then used as an index of the binocular balance across spatial frequency and compared against the contrast sensitivity ratio measured with the same stimuli. We observed that binocular matching becomes more imbalanced at high spatial frequency for amblyopes, compared with controls; that this imbalance did not depend in either group on whether the stimuli were presented simultaneously or successively; and that for both modes of presentation the matching balance correlates well with the interocular contrast sensitivity ratio (mean correlation coefficient of the slopes R = 0.7125). The results from our amblyopes show comparable losses of contrast perception at and above threshold under these binocular viewing conditions across a wide spatial frequency range, much stronger than that observed for our controls. This occurs under conditions in which there should be no dichoptic masking. Furthermore, the matching contrast could be well predicted by the monocular contrast sensitivity. Altogether, this suggests that amblyopic suppression cannot be explained by normal dichoptic masking but rather an attenuation of the input.

  6. Clay Mask Workshop

    ERIC Educational Resources Information Center

    Gamble, David L.

    2012-01-01

    Masks can represent so many things, such as emotions (happy, sad, fearful) and power. The familiar "comedy and tragedy" masks, derived from ancient Greek theater, are just one example from mask history. Death masks from the ancient Egyptians influenced the ancient Romans into creating similar masks for their departed. Masks can represent many…

  7. Adaptation to different noninvasive ventilation masks in critically ill patients*

    PubMed Central

    da Silva, Renata Matos; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta

    2013-01-01

    OBJECTIVE: To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. METHODS: An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. RESULTS: We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. CONCLUSIONS: In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed. PMID:24068269

  8. Adaptation to different noninvasive ventilation masks in critically ill patients.

    PubMed

    Silva, Renata Matos da; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta

    2013-01-01

    To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed.

  9. Influence of auditory fatigue on masked speech intelligibility

    NASA Technical Reports Server (NTRS)

    Parker, D. E.; Martens, W. L.; Johnston, P. A.

    1980-01-01

    Intelligibility of PB word lists embedded in simultaneous masking noise was evaluated before and after fatiguing-noise exposure, which was determined by observing the number of words correctly repeated during a shadowing task. Both the speech signal and the masking noise were filtered to a 2825-3185-Hz band. Masking-noise leves were varied from 0- to 90-dB SL. Fatigue was produced by a 1500-3000-Hz octave band of noise at 115 dB (re 20 micron-Pa) presented continuously for 5 min. The results of three experiments indicated that speed intelligibility was reduced when the speech was presented against a background of silence but that the fatiguing-noise exposure had no effect on intelligibility when the speech was made more intense and embedded in masking noise of 40-90-dB SL. These observations are interpreted by considering the recruitment produced by fatigue and masking noise.

  10. venice: Mask utility

    NASA Astrophysics Data System (ADS)

    Coupon, Jean

    2018-02-01

    venice reads a mask file (DS9 or fits type) and a catalogue of objects (ascii or fits type) to create a pixelized mask, find objects inside/outside a mask, or generate a random catalogue of objects inside/outside a mask. The program reads the mask file and checks if a point, giving its coordinates, is inside or outside the mask, i.e. inside or outside at least one polygon of the mask.

  11. Formal specification and verification of a fault-masking and transient-recovery model for digital flight-control systems

    NASA Technical Reports Server (NTRS)

    Rushby, John

    1991-01-01

    The formal specification and mechanically checked verification for a model of fault-masking and transient-recovery among the replicated computers of digital flight-control systems are presented. The verification establishes, subject to certain carefully stated assumptions, that faults among the component computers are masked so that commands sent to the actuators are the same as those that would be sent by a single computer that suffers no failures.

  12. A masking level difference due to harmonicity.

    PubMed

    Treurniet, W C; Boucher, D R

    2001-01-01

    The role of harmonicity in masking was studied by comparing the effect of harmonic and inharmonic maskers on the masked thresholds of noise probes using a three-alternative, forced-choice method. Harmonic maskers were created by selecting sets of partials from a harmonic series with an 88-Hz fundamental and 45 consecutive partials. Inharmonic maskers differed in that the partial frequencies were perturbed to nearby values that were not integer multiples of the fundamental frequency. Average simultaneous-masked thresholds were as much as 10 dB lower with the harmonic masker than with the inharmonic masker, and this difference was unaffected by masker level. It was reduced or eliminated when the harmonic partials were separated by more than 176 Hz, suggesting that the effect is related to the extent to which the harmonics are resolved by auditory filters. The threshold difference was not observed in a forward-masking experiment. Finally, an across-channel mechanism was implicated when the threshold difference was found between a harmonic masker flanked by harmonic bands and a harmonic masker flanked by inharmonic bands. A model developed to explain the observed difference recognizes that an auditory filter output envelope is modulated when the filter passes two or more sinusoids, and that the modulation rate depends on the differences among the input frequencies. For a harmonic masker, the frequency differences of adjacent partials are identical, and all auditory filters have the same dominant modulation rate. For an inharmonic masker, however, the frequency differences are not constant and the envelope modulation rate varies across filters. The model proposes that a lower variability facilitates detection of a probe-induced change in the variability, thus accounting for the masked threshold difference. The model was supported by significantly improved predictions of observed thresholds when the predictor variables included envelope modulation rate variance measured

  13. Mask etcher data strategy for 45nm and beyond

    NASA Astrophysics Data System (ADS)

    Lewington, Richard; Ibrahim, Ibrahim M.; Panayil, Sheeba; Kumar, Ajay; Yamartino, John

    2006-05-01

    Mask Etching for the 45nm technology node and beyond requires a system-level data and diagnostics strategy. This necessity stems from the need to control the performance of the mask etcher to increasingly stringent and diverse requirements of the mask production environment. Increasing mask costs and the capability to acquire and consolidate a wealth of data within the mask etch platform are primary motivators towards harnessing data mines for feedback into the mask etching optimization. There are offline and real-time possibilities and scenarios. Here, we discuss the data architecture, acquisition, and strategies of the Applied Materials Tetra II TM Mask Etch System.

  14. X-ray mask fabrication advancements at the Microlithographic Mask Development Center

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hughes, Patrick J.

    1996-05-01

    The Microlithographic Mask Development Center (MMD) was established as the X-ray mask manufacturing facility at the IBM Microelectronics Division semiconductor fabricator in Essex Junction, Vermont. This center, in operation for over two years, produces high yielding, defect-free X-ray masks for competitive logic and memory products at 250nm groundrules and below. The MMD is a complete mask facility that manufactures silicon membrane mask blanks in the NIST format and finished masks with electroplated gold X-ray absorber. Mask patterning, with dimensions as small as 180 nm, is accomplished using IBM-built variable shaped spot e-beam systems. Masks are routinely inspected and repaired using state-of-the-art equipment: two KLA SEM Specs for defect inspection, a Leica LMS 2000 for image placement characterization, an Amray 2040c for image dimension characterization and a Micrion 8000 XMR for defect repair. This facility maintains a baseline mask process with daily production of 250nm, 32Mb SRAM line monitor masks for the continuous improvement of mask quality and processes. Development masks are produced for several semiconductor manufacturers including IBM, Motorola, Loral, and Sanders. Masks for 64Mb and 256Mb DRAM (IBM) and advanced logic/SRAM (IBM and Motorola) designs have also been delivered. This paper describes the MMD facility and its technical capabilities. Key manufacturing metrics such as mask turnaround time, parametric yield learning and defect reduction activities are highlighted. The challenges associated with improved mask quality, sub-180nm mask fabrication, and the transition to refractory metal absorber are discussed.

  15. The contribution of forward masking to saccadic inhibition of return.

    PubMed

    Souto, David; Born, Sabine; Kerzel, Dirk

    2018-03-08

    Inhibition of return is the name typically given to the prolonged latency of motor responses directed to a previously cued target location. There is intense debate about the origins of this effect and its function, but most take for granted (despite lack of evidence) that it depends little on forward masking. Therefore, we re-examined the role of forward masking in inhibition of return. Forward masking was indexed by slower saccadic reaction times (SRTs) when the target orientation repeated the cue orientation at the same location. We confirmed effects of orientation repetition in the absence of an attentional bias when cues were presented on both sides of fixation (bilateral presentation). The effect of orientation repetition was reduced with high target contrast, consistent with a low-level origin such as contrast gain control in early visual areas. When presenting cues on only one side of fixation (unilateral presentation), we obtained inhibition of return with longer cue-target intervals and facilitation with targets presented shortly after the cue. The effect of orientation repetition was reduced when facilitation was observed, but was as strong as with bilateral cues when inhibition of return was observed. Therefore, forward masking may contribute to the inhibition of return effect by delaying reaction times to repeated features at the same location, but is not a principal cause of inhibition of return; in agreement with previous views. The saccadic inhibition of return effect is a reaction-time cost when responding to a pre-cued location. Additional object updating costs are typically invoked to explain reaction-time costs observed when cue and target have the same shape. Yet, lower-level, forward masking of the target by the cue can not be ruled out. Importantly, we show an effect of orientation repetition that is consistent with low-level forward masking rather than object updating costs and that does not interact with inhibition of return.

  16. Is masked priming modulated by memory load? A test of the automaticity of masked identity priming in lexical decision.

    PubMed

    Perea, Manuel; Marcet, Ana; Lozano, Mario; Gomez, Pablo

    2018-05-29

    One of the key assumptions of the masked priming lexical decision task (LDT) is that primes are processed without requiring attentional resources. Here, we tested this assumption by presenting a dual-task manipulation to increase memory load and measure the change in masked identity priming on the targets in the LDT. If masked priming does not require attentional resources, increased memory load should have no influence on the magnitude of the observed identity priming effects. We conducted two LDT experiments, using a within-subjects design, to investigate the effect of memory load (via a concurrent matching task Experiment 1 and a concurrent search task in Experiment 2) on masked identity priming. Results showed that the magnitude of masked identity priming on word targets was remarkably similar under high and low memory load. Thus, these experiments provide empirical evidence for the automaticity assumption of masked identity priming in the LDT.

  17. Optical inspection of NGL masks

    NASA Astrophysics Data System (ADS)

    Pettibone, Donald W.; Stokowski, Stanley E.

    2004-12-01

    For the last five years KLA-Tencor and our joint venture partners have pursued a research program studying the ability of optical inspection tools to meet the inspection needs of possible NGL lithographies. The NGL technologies that we have studied include SCALPEL, PREVAIL, EUV lithography, and Step and Flash Imprint Lithography. We will discuss the sensitivity of the inspection tools and mask design factors that affect tool sensitivity. Most of the work has been directed towards EUV mask inspection and how to optimize the mask to facilitate inspection. Our partners have succeeded in making high contrast EUV masks ranging in contrast from 70% to 98%. Die to die and die to database inspection of EUV masks have been achieved with a sensitivity that is comparable to what can be achieved with conventional photomasks, approximately 80nm defect sensitivity. We have inspected SCALPEL masks successfully. We have found a limitation of optical inspection when applied to PREVAIL stencil masks. We have run inspections on SFIL masks in die to die, reflected light, in an effort to provide feedback to improve the masks. We have used a UV inspection system to inspect both unpatterned EUV substrates (no coatings) and blanks (with EUV multilayer coatings). These inspection results have proven useful in driving down the substrate and blank defect levels.

  18. Laryngeal mask airway for airway control during percutaneous dilatational tracheostomy.

    PubMed

    Pratt, T; Bromilow, J

    2011-11-01

    Percutaneous dilatational tracheostomy is a common bedside procedure in critical care for patients requiring prolonged mechanical ventilation. The traditional technique requires withdrawal of the endotracheal tube to a proximal position to facilitate tracheostomy insertion, but this carries the risk of inadvertent extubation and does not prevent cuff rupture. Use of a supraglottic airway such as the laryngeal mask airway may avoid these risks and could provide a safe alternative to the endotracheal tube. We present an appraisal of the literature to date. We found reasonable evidence to show improved ventilation and bronchoscopic visualisation with the laryngeal mask airway, but this has not been translated into improved outcome. There is currently insufficient evidence to draw conclusions about the safety of the laryngeal mask airway during percutaneous dilatational tracheostomy.

  19. From randomized controlled trials to observational studies.

    PubMed

    Silverman, Stuart L

    2009-02-01

    Randomized controlled trials are considered the gold standard in the hierarchy of research designs for evaluating the efficacy and safety of a treatment intervention. However, their results can have limited applicability to patients in clinical settings. Observational studies using large health care databases can complement findings from randomized controlled trials by assessing treatment effectiveness in patients encountered in day-to-day clinical practice. Results from these designs can expand upon outcomes of randomized controlled trials because of the use of larger and more diverse patient populations with common comorbidities and longer follow-up periods. Furthermore, well-designed observational studies can identify clinically important differences among therapeutic options and provide data on long-term drug effectiveness and safety.

  20. Filter penetration and breathing resistance evaluation of respirators and dust masks.

    PubMed

    Ramirez, Joel; O'Shaughnessy, Patrick

    2017-02-01

    The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p < 0.001). The breathing resistances of the unused FFRs and dust masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p < 0.001). After dust loading there was a significant difference between the BR caused by the ARD dust layer on each FFR and dust mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values < 5% and quality factors (0.26 and 0.33) comparable to those obtained for the two FFRs (0.23 and 0.31). However, the remaining three dust masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.

  1. Study of a coronagraphic mask using evanescent waves.

    PubMed

    Buisset, Christophe; Rabbia, Yves; Lepine, Thierry; Alagao, Mary-Angelie; Ducrot, Elsa; Poshyachinda, Saran; Soonthornthum, Boonrucksar

    2017-04-03

    The evanescent wave coronagraph (EvWaCo) is a specific kind of band-limited coronagraph using the frustrated total internal reflection phenomenon to produce the coronagraphic effect (removing starlight from the image plane in order to make the stellar environment detectable). In this paper, we present a theoretical and experimental study of the EvWaCo coronagraphic mask. First, we calculate the theoretical transmission and we show that this mask is partially achromatic. Then, we present the experimental results obtained in unpolarized light at the wavelength λ≈900 nm and relative spectral bandwidth Δλ/λ≈6%. In particular, we show that the coronagraph provides a contrast down to a few 10-6 at an angular distance of about ten Airy radii.

  2. Disposable surgical face masks for preventing surgical wound infection in clean surgery.

    PubMed

    Vincent, Marina; Edwards, Peggy

    2016-04-26

    Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. To determine whether the wearing of disposable surgical face masks by the surgical team during clean surgery reduces postoperative surgical wound infection. In December 2015, for this seventh update, we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials; Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched the bibliographies of all retrieved and relevant publications. There were no restrictions with respect to language, date of publication or study setting. Randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing the use of disposable surgical masks with the use of no mask. Two review authors extracted data independently. We included three trials, involving a total of 2106 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. We identified no new trials for this latest update. From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  3. Masking Release in Children and Adults With Hearing Loss When Using Amplification

    PubMed Central

    McCreery, Ryan; Kopun, Judy; Lewis, Dawna; Alexander, Joshua; Stelmachowicz, Patricia

    2016-01-01

    Purpose This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method Sentence recognition in unmodulated noise was compared with recognition in modulated noise (masking release). Recognition was measured for participants with hearing loss using individualized amplification via the hearing-aid simulator. Results Adults with hearing loss showed greater masking release than the children with hearing loss. Average masking release was small (1 dB) and did not depend on hearing status. Masking release was comparable for slow and fast compression. Conclusions The use of amplification in this study contrasts with previous studies that did not use amplification. The results suggest that when differences in audibility are reduced, participants with hearing loss may be able to take advantage of dips in the noise levels, similar to participants with normal hearing. Although children required a more favorable signal-to-noise ratio than adults for both unmodulated and modulated noise, masking release was not statistically different. However, the ability to detect a difference may have been limited by the small amount of masking release observed. PMID:26540194

  4. Mask characterization for CDU budget breakdown in advanced EUV lithography

    NASA Astrophysics Data System (ADS)

    Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho

    2012-11-01

    As the ITRS Critical Dimension Uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and a high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. In this paper we will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for an advanced EUV lithography with 1D and 2D feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CD's and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples in this paper. Also mask stack reflectivity variations should be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We observed also MEEF-through-field fingerprints in the studied EUV cases. Variations of MEEF may also play a role for the total intrafield CDU and may be taken into account for EUV Lithography. We characterized MEEF-through-field for the reviewed features, the results to be discussed in our paper, but further analysis of this phenomenon is required. This comprehensive approach to characterization of the mask part of EUV CDU characterization delivers an accurate and integral CDU Budget

  5. The Q Continuum: Encounter with the Cloud Mask

    NASA Astrophysics Data System (ADS)

    Ackerman, S. A.; Frey, R.; Holz, R.; Philips, C.; Dutcher, S.

    2017-12-01

    We are developing a common cloud mask for MODIS and VIIRS observations, referred to as the MODIS VIIRS Continuity Mask (MVCM). Our focus is on extending the MODIS-heritage cloud detection approach in order to generate appropriate climate data records for clouds and climate studies. The MVCM is based on heritage from the MODIS cloud mask (MOD35 and MYD35) and employs a series of tests on MODIS reflectances and brightness temperatures. Cloud detection is based on contrasts (i.e., cloud versus background surface) at pixel resolution. The MVCM follows the same approach. These cloud masks use multiple cloud detection tests to indicate the confidence level that the observation is of a clear-sky scene. The outcome of a test ranges from 0 (cloudy) to 1 (clear-sky scene). Because of overlap in the sensitivities of the various spectral tests to the type of cloud, each test is considered in one of several groups. The final cloud mask is determined from the product of the minimum confidence of each group and is referred to as the Q value as defined in Ackerman et al (1998). In MOD35 and MYD35 processing, the Q value is not output, rather predetermined Q values determine the result: If Q ≥ .99 the scene is clear; .95 ≤ Q < .99 the pixel is probably a clear scene, .66 ≤ Q < .95 is probably cloudy and Q < .66 is cloudy. Thus representing Q discretely and not as a continuum. For the MVCM, the numerical value of the Q is output along with the classification of clear, probably clear, probably cloudy, and cloudy. Through comparisons with collocated CALIOP and MODIS observations, we will assess the categorization of the Q values as a function of scene type ). While validation studies have indicated the utility and statistical correctness of the cloud mask approach, the algorithm does not possess immeasurable power and perfection. This comparison will assess the time and space dependence of Q and assure that the laws of physics are followed, at least according to normal human

  6. Force-dependent static dead space of face masks used with holding chambers.

    PubMed

    Shah, Samir A; Berlinski, Ariel B; Rubin, Bruce K

    2006-02-01

    Pressurized metered-dose inhalers with valved holding chambers and masks are commonly used for aerosol delivery in children. Drug delivery can decrease when the dead-space volume (DSV) of the valved holding chamber is increased, but there are no published data evaluating force-dependent DSV among different masks. Seven masks were studied. Masks were sealed at the valved holding chamber end and filled with water to measure mask volume. To measure mask DSV we used a mannequin of 2-year-old-size face and we applied the mask with forces of 1.5, 3.5, and 7 pounds. Mask seal was determined by direct observation. Intra-brand analysis was done via analysis of variance. At 3.5 pounds of force, the DSV ranged from 29 mL to 100 mL, with 3 masks having DSV of < 50 mL. The remaining masks all had DSV > 60 mL. At 3.5 pounds of force, DSV percent of mask volume ranged from 33.7% (Aerochamber, p < 0.01 compared with other masks) to 100% (Pocket Chamber). DSV decreased with increasing force with most of the masks, and the slope of this line was inversely proportional to mask flexibility. Mask fit was 100% at 1.5 pounds of force only with the Aerochamber and Optichamber. Mask fit was poorest with the Vortex, Pocket Chamber, and BreatheRite masks. Rigid masks with large DSV might not be not suitable for use in children, especially if discomfort from the stiff mask makes its use less acceptable to the child.

  7. The effectiveness of nasal mask vs face mask ventilation in anesthetized, apneic pediatric subjects over 2 years of age: a randomized controlled trial.

    PubMed

    Itagaki, Taiga; Gubin, Tatyana A; Sayal, Puneet; Jiang, Yandong; Kacmarek, Robert M; Anderson, Thomas Anthony

    2016-02-01

    We hypothesized that anesthetized, apneic children could be ventilated equivalently or more efficiently by nasal mask ventilation (NMV) than face mask ventilation (FMV). The aim of this randomized controlled study was to test this hypothesis by comparing the expiratory tidal volume (Vte) between NMV and FMV. After the induction of anesthesia, 41 subjects, 3-17 years of age without anticipated difficult mask ventilation, were randomly assigned to receive either NMV or FMV with neck extension. Both groups were ventilated with pressure control ventilation (PCV) at 20 cmH2 O of peak inspiratory pressure (PIP) with positive end-expiratory pressure (PEEP) levels of 0, 5, and 10 cmH2 O. An additional mouth closing maneuver (MCM) was applied for the NMV group. The Vte was higher in the FMV group compared with the NMV group (median difference [95% CI]: 8.4 [5.5-11.6] ml·kg(-1) ; P < 0.001) when MCM was not applied. NMV achieved less PEEP than FMV (median difference [95% CI]: 5.0 [4.3-5.3] cmH2 O at 10 cmH2 O; P < 0.001) though both groups achieved the set PIP level. In the NMV group, MCM markedly increased Vte (median increase [95% CI]: 5.9 [2.5-9.0] ml·kg(-1) ; P < 0.005) and PEEP (median increase [95% CI]: 5.0 [0.6-8.6] cmH2 O at 10 cmH2 O; P < 0.005); however, PEEP was highly variable and lower than that of FMV (median difference [95% CI]: 2.5 [0.8-8.5] cmH2 O at 10 cmH2 O; P < 0.05). In anesthetized, apneic children greater than 2 years of age ventilated with an anesthesia ventilator and neck extension, FMV established a greater Vte than NMV regardless of mouth status. NMV could not maintain the set PEEP level due to an air leak from the mouth. The MCM increased the Vte and PEEP. © 2016 John Wiley & Sons Ltd.

  8. A novel anti-influenza copper oxide containing respiratory face mask.

    PubMed

    Borkow, Gadi; Zhou, Steve S; Page, Tom; Gabbay, Jeffrey

    2010-06-25

    Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10)TCID(50) of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (< or = 0.88 log(10)TCID(50)), while 4.67+/-1.35 log(10)TCID(50) were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were < or = 0.97+/-0.01 log(10)TCID(50) and from the control masks 5.03+/-0.54 log(10)TCID(50). The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk

  9. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    PubMed

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  10. Masked Hypertension and Incident Clinic Hypertension among African Americans in the Jackson Heart Study

    PubMed Central

    Abdalla, Marwah; Booth, John N.; Seals, Samantha R.; Spruill, Tanya M.; Viera, Anthony J.; Diaz, Keith M.; Sims, Mario; Muntner, Paul; Shimbo, Daichi

    2016-01-01

    Masked hypertension, defined as non-elevated clinic blood pressure and elevated out-of-clinic blood pressure may be an intermediary stage in the progression from normotension to hypertension. We examined the associations of out-of-clinic blood pressure and masked hypertension using ambulatory blood pressure monitoring with incident clinic hypertension in the Jackson Heart Study, a prospective cohort of African Americans. Analyses included 317 participants with clinic blood pressure <140/90mmHg, complete ABPM, who were not taking antihypertensive medication at baseline in 2000–2004. Masked daytime hypertension was defined as mean daytime blood pressure ≥135/85mmHg; masked nighttime hypertension as mean nighttime blood pressure ≥120/70mmHg; and masked 24-hour hypertension as mean 24-hour blood pressure ≥130/80mmHg. Incident clinic hypertension, assessed at study visits in 2005–2008 and 2009–2012, was defined as the first visit with clinic systolic/diastolic blood pressure ≥140/90mmHg or antihypertensive medication use. During a median follow-up of 8.1 years, there were 187 (59.0%) incident cases of clinic hypertension. Clinic hypertension developed in 79.2% and 42.2% of participants with and without any masked hypertension, 85.7% and 50.4% with and without masked daytime hypertension, 79.9% and 43.7% with and without masked nighttime hypertension and 85.7% and 48.2% with and without masked 24-hour hypertension, respectively. Multivariable-adjusted hazard ratios (95% CI) of incident clinic hypertension for any masked hypertension and masked daytime, nighttime, and 24-hour hypertension were 2.13 (1.51–3.02), 1.79 (1.24–2.60), 2.22 (1.58–3.12), and 1.91 (1.32–2.75), respectively. These findings suggest that ambulatory blood pressure monitoring can identify African Americans at increased risk for developing clinic hypertension. PMID:27185746

  11. Emotional conditioning to masked stimuli and modulation of visuospatial attention.

    PubMed

    Beaver, John D; Mogg, Karin; Bradley, Brendan P

    2005-03-01

    Two studies investigated the effects of conditioning to masked stimuli on visuospatial attention. During the conditioning phase, masked snakes and spiders were paired with a burst of white noise, or paired with an innocuous tone, in the conditioned stimulus (CS)+ and CS- conditions, respectively. Attentional allocation to the CSs was then assessed with a visual probe task, in which the CSs were presented unmasked (Experiment 1) or both unmasked and masked (Experiment 2), together with fear-irrelevant control stimuli (flowers and mushrooms). In Experiment 1, participants preferentially allocated attention to CS+ relative to control stimuli. Experiment 2 suggested that this attentional bias depended on the perceived aversiveness of the unconditioned stimulus and did not require conscious recognition of the CSs during both acquisition and expression. Copyright 2005 APA, all rights reserved.

  12. Increased dead space in face mask continuous positive airway pressure in neonates.

    PubMed

    Hishikawa, Kenji; Fujinaga, Hideshi; Ito, Yushi

    2017-01-01

    Continuous positive airway pressure (CPAP) by face mask is commonly performed in newborn resuscitation. We evaluated the effect of face mask CPAP on system dead space. Face mask CPAP increases dead space. A CPAP model study. We estimated the volume of the inner space of the mask. We devised a face mask CPAP model, in which the outlet of the mask was covered with plastic; and three modified face mask CPAP models, in which holes were drilled near to the cushion of the covered face mask to alter the air exit. We passed a continuous flow of 21% oxygen through each model and we controlled the inner pressure to 5 cmH 2 O by adjusting the flow-relief valve. To evaluate the ventilation in the inner space of each model, we measured the oxygen concentration rise time, that is, the time needed for the oxygen concentration of each model to reach 35% after the oxygen concentration of the continuous flow was raised from 21% to 40%. The volume of inner space of the face mask was 38.3 ml. Oxygen concentration rise time in the face mask CPAP model was significantly longer at various continuous flow rates and points of the inner space of the face mask compared with that of the modified face mask CPAP model. Our study indicates that face mask CPAP leads to an increase in dead space and a decrease in ventilation efficiency under certain circumstances. Pediatr Pulmonol. 2017;52:107-111. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. [Laryngeal mask].

    PubMed

    Villaverde Rozados, María José; Mos Reguera, M Esther; González Argibay, M Concepción; Sixto Gato, Sandra; Radío, Beatriz Alfonso; Fernández Díaz, María José

    2003-11-01

    A laryngeal mask is a very useful instrument to use both in easy as well as difficult handling situations related to the air tract. This mask is placed in the pharynx and it permits a patient to breathe in different modes, either spontaneously or mechanically. Different models are available; some even facilitate the tracheal intubation through the mask. The authors highlight that this type of mask does not protect nor isolate the air tract. As advantages, the authors point out its easy installation; thus, it is an alternative when an air tract presents difficulties; therefore, it is necessary that all personnel who have to deal with the air tract be aware of this mask and know how to handle it.

  14. Control of odour nuisance in urban areas: the efficiency and social acceptance of the application of masking agents.

    PubMed

    Lazarova, Valentina; Abed, Brahim; Markovska, Gabriela; Dezenclos, Thierry; Amara, Aït

    2013-01-01

    This paper presents and discusses the results of the project named 'Jasmin' implemented in Algiers to control the strong odours of the river named Oued El Harrach, one of the largest rivers in the centre of the city. Pending the achievement of curative solutions, a temporary option for mitigation of nuisance odour by masking agents was implemented in the vicinity of the main bridges. The efficiency of this technology has been followed by means of an odour panel with the participation of representatives of all stakeholders. A sociological study by means of 1,000 questionnaires and face-to-face interviews of the local population demonstrated the benefits and the positive outcomes of the attenuation of odour nuisance: 70% of the surveyed population is satisfied or very satisfied with the application of masking agents and 96% of respondents support the continuation of the project. In terms of size and public access, the project Jasmin is a world-first demonstration of odour control in urban areas in developing countries.

  15. Improved mask-based CD uniformity for gridded-design-rule lithography

    NASA Astrophysics Data System (ADS)

    Faivishevsky, Lev; Khristo, Sergey; Sagiv, Amir; Mangan, Shmoolik

    2009-03-01

    The difficulties encountered during lithography of state-of-the-art 2D patterns are formidable, and originate from the fact that deep sub-wavelength features are being printed. This results in a practical limit of k1 >=0.4 as well as a multitude of complex restrictive design rules, in order to mitigate or minimize lithographic hot spots. An alternative approach, that is gradually attracting the lithographic community's attention, restricts the design of critical layers to straight, dense lines (a 1D grid), that can be relatively easily printed using current lithographic technology. This is then followed by subsequent, less critical trimming stages to obtain circuit functionality. Thus, the 1D gridded approach allows hotspot-free, proximity-effect free lithography of ultra low- k1 features. These advantages must be supported by a stable CD control mechanism. One of the overriding parameters impacting CDU performance is photo mask quality. Previous publications have demonstrated that IntenCDTM - a novel, mask-based CDU mapping technology running on Applied Materials' Aera2TM aerial imaging mask inspection tool - is ideally fit for detecting mask-based CDU issues in 1D (L&S) patterned masks for memory production. Owing to the aerial nature of image formation, IntenCD directly probes the CD as it is printed on the wafer. In this paper we suggest that IntenCD is naturally fit for detecting mask-based CDU issues in 1D GDR masks. We then study a novel method of recovering and quantifying the physical source of printed CDU, using a novel implementation of the IntenCD technology. We demonstrate that additional, simple measurements, which can be readily performed on board the Aera2TM platform with minimal throughput penalty, may complement IntenCD and allow a robust estimation of the specific nature and strength of mask error source, such as pattern width variation or phase variation, which leads to CDU issues on the printed wafer. We finally discuss the roles played by

  16. Summation versus suppression in metacontrast masking: On the potential pitfalls of using metacontrast masking to assess perceptual-motor dissociation.

    PubMed

    Cardoso-Leite, Pedro; Waszak, Florian

    2014-07-01

    A briefly flashed target stimulus can become "invisible" when immediately followed by a mask-a phenomenon known as backward masking, which constitutes a major tool in the cognitive sciences. One form of backward masking is termed metacontrast masking. It is generally assumed that in metacontrast masking, the mask suppresses activity on which the conscious perception of the target relies. This assumption biases conclusions when masking is used as a tool-for example, to study the independence between perceptual detection and motor reaction. This is because other models can account for reduced perceptual performance without requiring suppression mechanisms. In this study, we used signal detection theory to test the suppression model against an alternative view of metacontrast masking, referred to as the summation model. This model claims that target- and mask-related activations fuse and that the difficulty in detecting the target results from the difficulty to discriminate this fused response from the response produced by the mask alone. Our data support this alternative view. This study is not a thorough investigation of metacontrast masking. Instead, we wanted to point out that when a different model is used to account for the reduced perceptual performance in metacontrast masking, there is no need to postulate a dissociation between perceptual and motor responses to account for the data. Metacontrast masking, as implemented in the Fehrer-Raab situation, therefore is not a valid method to assess perceptual-motor dissociations.

  17. Determining the energetic and informational components of speech-on-speech masking

    PubMed Central

    Kidd, Gerald; Mason, Christine R.; Swaminathan, Jayaganesh; Roverud, Elin; Clayton, Kameron K.; Best, Virginia

    2016-01-01

    Identification of target speech was studied under masked conditions consisting of two or four independent speech maskers. In the reference conditions, the maskers were colocated with the target, the masker talkers were the same sex as the target, and the masker speech was intelligible. The comparison conditions, intended to provide release from masking, included different-sex target and masker talkers, time-reversal of the masker speech, and spatial separation of the maskers from the target. Significant release from masking was found for all comparison conditions. To determine whether these reductions in masking could be attributed to differences in energetic masking, ideal time-frequency segregation (ITFS) processing was applied so that the time-frequency units where the masker energy dominated the target energy were removed. The remaining target-dominated “glimpses” were reassembled as the stimulus. Speech reception thresholds measured using these resynthesized ITFS-processed stimuli were the same for the reference and comparison conditions supporting the conclusion that the amount of energetic masking across conditions was the same. These results indicated that the large release from masking found under all comparison conditions was due primarily to a reduction in informational masking. Furthermore, the large individual differences observed generally were correlated across the three masking release conditions. PMID:27475139

  18. Visual Masking in Schizophrenia: Overview and Theoretical Implications

    PubMed Central

    Green, Michael F.; Lee, Junghee; Wynn, Jonathan K.; Mathis, Kristopher I.

    2011-01-01

    Visual masking provides several key advantages for exploring the earliest stages of visual processing in schizophrenia: it allows for control over timing at the millisecond level, there are several well-supported theories of the underlying neurobiology of visual masking, and it is amenable to examination by electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI). In this paper, we provide an overview of the visual masking impairment schizophrenia, including the relevant theoretical mechanisms for masking impairment. We will discuss its relationship to clinical symptoms, antipsychotic medications, diagnostic specificity, and presence in at-risk populations. As part of this overview, we will cover the neural correlates of visual masking based on recent findings from EEG and fMRI. Finally, we will suggest a possible mechanism that could explain the patterns of masking findings and other visual processing findings in schizophrenia. PMID:21606322

  19. Emergency face-mask removal effectiveness: a comparison of traditional and nontraditional football helmet face-mask attachment systems.

    PubMed

    Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W

    2010-01-01

    Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20)  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20)  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20)  =  43.20, P  =  .001), with participants reporting average

  20. Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

    PubMed Central

    Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.

    2010-01-01

    Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected

  1. Effect of SPM-based cleaning POR on EUV mask performance

    NASA Astrophysics Data System (ADS)

    Choi, Jaehyuck; Lee, Han-shin; Yoon, Jinsang; Shimomura, Takeya; Friz, Alex; Montgomery, Cecilia; Ma, Andy; Goodwin, Frank; Kang, Daehyuk; Chung, Paul; Shin, Inkyun; Cho, H.

    2011-11-01

    EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. The fact that a pellicle is not used to protect the mask surface in EUV lithography suggests that EUV masks may have to undergo more cleaning cycles during their lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality and patterning performance during 30 cycles of Samsung's EUV mask SPM-based cleaning and 20 cycles of SEMATECH ADT exposure. We have observed that the quality and patterning performance of EUV masks does not significantly change during these processes except mask pattern CD change. To resolve this issue, we have developed an acid-free cleaning POR and substantially improved EUV mask film loss compared to the SPM-based cleaning POR.

  2. Refinement of the CALIOP cloud mask algorithm

    NASA Astrophysics Data System (ADS)

    Katagiri, Shuichiro; Sato, Kaori; Ohta, Kohei; Okamoto, Hajime

    2018-04-01

    A modified cloud mask algorithm was applied to the CALIOP data to have more ability to detect the clouds in the lower atmosphere. In this algorithm, we also adopt the fully attenuation discrimination and the remain noise estimation using the data obtained at an altitude of 40 km to avoid contamination of stratospheric aerosols. The new cloud mask shows an increase in the lower cloud fraction. Comparison of the results to the data observed with a PML ground observation was also made.

  3. Oronasal masks require higher levels of positive airway pressure than nasal masks to treat obstructive sleep apnea.

    PubMed

    Bettinzoli, Michela; Taranto-Montemurro, Luigi; Messineo, Ludovico; Corda, Luciano; Redolfi, Stefania; Ferliga, Mauro; Tantucci, Claudio

    2014-12-01

    The purpose of this study was to compare the therapeutic pressure determined by an automated CPAP device (AutoCPAP) during the titration period, between nasal and oronasal mask and the residual apnea-hypopnea index (AHI) on a subsequent poligraphy performed with the established therapeutic CPAP. As a retrospective study, 109 subjects with moderate and severe obstructive sleep apnea-hypopnea (apnea-hypopnea index≥15 events/h) were studied. CPAP titration was performed using an auto-titrating device. There was significant difference in the mean pressure delivered with autoCPAP between the group of patients using the nasal mask (mean 10.0 cmH2O±2.0 SD) and the group which used the oronasal mask (mean 11.2 cmH2O±2.1) (p<0.05). Residual apneas were lower when using a nasal mask: average AHI of 2.6±2.5 compared to 4.5±4.0 using an oronasal mask (p<0.05). On multivariate analysis, the only independent predictor of the level of therapeutic pressure of CPAP was the type of mask used (r=0.245, p 0.008). Therapeutic CPAP level for OSAH is higher when administered via oronasal mask, leaving more residual events. These findings suggest that nasal mask should be the first choice for OSAH treatment.

  4. Temporal masking of multidimensional tactual stimuli

    NASA Astrophysics Data System (ADS)

    Tan, Hong Z.; Reed, Charlotte M.; Delhorne, Lorraine A.; Durlach, Nathaniel I.; Wan, Natasha

    2003-12-01

    Experiments were performed to examine the temporal masking properties of multidimensional tactual stimulation patterns delivered to the left index finger. The stimuli consisted of fixed-frequency sinusoidal motions in the kinesthetic (2 or 4 Hz), midfrequency (30 Hz), and cutaneous (300 Hz) frequency ranges. Seven stimuli composed of one, two, or three spectral components were constructed at each of two signal durations (125 or 250 ms). Subjects identified target signals under three different masking paradigms: forward masking, backward masking, and sandwiched masking (in which the target is presented between two maskers). Target identification was studied as a function of interstimulus interval (ISI) in the range 0 to 640 ms. For both signal durations, percent-correct scores increased with ISI for each of the three masking paradigms. Scores with forward and backward masking were similar and significantly higher than scores obtained with sandwiched masking. Analyses of error trials revealed that subjects showed a tendency to respond, more often than chance, with the masker, the composite of the masker and target, or the combination of the target and a component of the masker. The current results are compared to those obtained in previous studies of tactual recognition masking with brief cutaneous spatial patterns. The results are also discussed in terms of estimates of information transfer (IT) and IT rate, are compared to previous studies with multidimensional tactual signals, and are related to research on the development of tactual aids for the deaf.

  5. The effect of foveal and parafoveal masks on the eye movements of older and younger readers.

    PubMed

    Rayner, Keith; Yang, Jinmian; Schuett, Susanne; Slattery, Timothy J

    2014-06-01

    In the present study, we examined foveal and parafoveal processing in older compared with younger readers by using gaze-contingent paradigms with 4 conditions. Older and younger readers read sentences in which the text was either a) presented normally, b) the foveal word was masked as soon as it was fixated, c) all of the words to the left of the fixated word were masked, or d) all of the words to the right of the fixated word were masked. Although older and younger readers both found reading when the fixated word was masked quite difficult, the foveal mask increased sentence reading time more than 3-fold (3.4) for the older readers (in comparison with the control condition in which the sentence was presented normally) compared with the younger readers who took 1.3 times longer to read sentences in the foveal mask condition (in comparison with the control condition). The left and right parafoveal masks did not disrupt reading as severely as the foveal mask, though the right mask was more disruptive than the left mask. Also, there was some indication that the younger readers found the right mask condition relatively more disruptive than the left mask condition. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  6. Masking reduces orientation selectivity in rat visual cortex

    PubMed Central

    Alwis, Dasuni S.; Richards, Katrina L.

    2016-01-01

    In visual masking the perception of a target stimulus is impaired by a preceding (forward) or succeeding (backward) mask stimulus. The illusion is of interest because it allows uncoupling of the physical stimulus, its neuronal representation, and its perception. To understand the neuronal correlates of masking, we examined how masks affected the neuronal responses to oriented target stimuli in the primary visual cortex (V1) of anesthetized rats (n = 37). Target stimuli were circular gratings with 12 orientations; mask stimuli were plaids created as a binarized sum of all possible target orientations. Spatially, masks were presented either overlapping or surrounding the target. Temporally, targets and masks were presented for 33 ms, but the stimulus onset asynchrony (SOA) of their relative appearance was varied. For the first time, we examine how spatially overlapping and center-surround masking affect orientation discriminability (rather than visibility) in V1. Regardless of the spatial or temporal arrangement of stimuli, the greatest reductions in firing rate and orientation selectivity occurred for the shortest SOAs. Interestingly, analyses conducted separately for transient and sustained target response components showed that changes in orientation selectivity do not always coincide with changes in firing rate. Given the near-instantaneous reductions observed in orientation selectivity even when target and mask do not spatially overlap, we suggest that monotonic visual masking is explained by a combination of neural integration and lateral inhibition. PMID:27535373

  7. My Other Half Manifested in Mask-Making

    ERIC Educational Resources Information Center

    Abel, Xanthippi

    2010-01-01

    Every fall season, each grade level of Rowland Hall St. Mark's Lower School in Salt Lake City, Utah, completes a mask-making project to be featured in a schoolwide parade. This sparked an opportunity to incorporate the fourth-grade unit of realistic and observational drawing with mask making. In this article, the author describes how her students…

  8. Individual differences in metacontrast masking regarding sensitivity and response bias.

    PubMed

    Albrecht, Thorsten; Mattler, Uwe

    2012-09-01

    In metacontrast masking target visibility is modulated by the time until a masking stimulus appears. The effect of this temporal delay differs across participants in such a way that individual human observers' performance shows distinguishable types of masking functions which remain largely unchanged for months. Here we examined whether individual differences in masking functions depend on different response criteria in addition to differences in discrimination sensitivity. To this end we reanalyzed previously published data and conducted a new experiment for further data analyses. Our analyses demonstrate that a distinction of masking functions based on the type of masking stimulus is superior to a distinction based on the target-mask congruency. Individually different masking functions are based on individual differences in discrimination sensitivities and in response criteria. Results suggest that individual differences in metacontrast masking result from individually different criterion contents. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. A face versus non-face context influences amygdala responses to masked fearful eye whites.

    PubMed

    Kim, M Justin; Solomon, Kimberly M; Neta, Maital; Davis, F Caroline; Oler, Jonathan A; Mazzulla, Emily C; Whalen, Paul J

    2016-12-01

    The structure of the mask stimulus is crucial in backward masking studies and we recently demonstrated such an effect when masking faces. Specifically, we showed that activity of the amygdala is increased to fearful facial expressions masked with neutral faces and decreased to fearful expressions masked with a pattern mask-but critically both masked conditions discriminated fearful expressions from happy expressions. Given this finding, we sought to test whether masked fearful eye whites would produce a similar profile of amygdala response in a face vs non-face context. During functional magnetic resonance imaging scanning sessions, 30 participants viewed fearful or happy eye whites masked with either neutral faces or pattern images. Results indicated amygdala activity was increased to fearful vs happy eye whites in the face mask condition, but decreased to fearful vs happy eye whites in the pattern mask condition-effectively replicating and expanding our previous report. Our data support the idea that the amygdala is responsive to fearful eye whites, but that the nature of this activity observed in a backward masking design depends on the mask stimulus. © The Author (2016). Published by Oxford University Press.

  10. Binaural masking release in children with Down syndrome.

    PubMed

    Porter, Heather L; Grantham, D Wesley; Ashmead, Daniel H; Tharpe, Anne Marie

    2014-01-01

    with Down syndrome and control adults had similar MLDs. Similarities in simulated spatial release from masking were observed for all groups for the experimental parameters used in this study. No association was observed for any measure of binaural ability and developmental age for children with Down syndrome. Similar group psychometric functions were observed for children with Down syndrome and typically developing children in most instances, suggesting that attentiveness and motivation contributed equally to performance for both groups on most tasks. The binaural advantages afforded to typically developing children, such as enhanced hearing sensitivity in noise, were not as robust for children with Down syndrome in this study. Children with Down syndrome experienced less binaural benefit than typically developing peers for some stimuli, suggesting that they could require more favorable signal-to-noise ratios to achieve optimal performance in some adverse listening conditions. The reduced release from masking observed for children with Down syndrome could represent a delay in ability rather than a deficit that persists into adulthood. This could have implications for the planning of interventions for individuals with Down syndrome.

  11. Neuroimaging somatosensory perception and masking.

    PubMed

    Meador, Kimford J; Revill, Kathleen Pirog; Epstein, Charles M; Sathian, K; Loring, David W; Rorden, Chris

    2017-01-08

    The specific cortical and subcortical regions involved in conscious perception and masking are uncertain. This study sought to identify brain areas involved in conscious perception of somatosensory stimuli during a masking task using functional magnetic resonance (fMRI) to contrast perceived vs. non-perceived targets. Electrical trains were delivered to the right index finger for targets and to the left index finger for masks. Target intensities were adjusted to compensate for threshold drift. Sham target trials were given in ~10% of the trials, and target stimuli without masks were delivered in one of the five runs (68 trials/run). When healthy dextral adult volunteers (n=15) perceived right hand targets, greater left- than right-cerebral activations were seen with similar patterns across the parietal cortex, thalamus, insula, claustrum, and midbrain. When targets were not perceived, left/right cerebral activations were similar overall. Directly comparing perceived vs. non-perceived stimuli with similar intensities in the masking task revealed predominate activations contralateral to masks. In contrast, activations were greater contralateral to perceived targets if no masks were given or if masks were given but target stimulus intensities were greater for perceived than non-perceived targets. The novel aspects of this study include: 1) imaging of cortical and subcortical activations in healthy humans related to somatosensory perception during a masking task, 2) activations in the human thalamus and midbrain related to perception of stimuli compared to matched non-perceived stimuli, and 3) similar left/right cerebral activation patterns across cortical, thalamic and midbrain structures suggesting interactions across all three levels during conscious perception in humans. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Prediction and outcomes of impossible mask ventilation: a review of 50,000 anesthetics.

    PubMed

    Kheterpal, Sachin; Martin, Lizabeth; Shanks, Amy M; Tremper, Kevin K

    2009-04-01

    There are no existing data regarding risk factors for impossible mask ventilation and limited data regarding its incidence. The authors sought to determine the incidence, predictors, and outcomes associated with impossible mask ventilation. The authors performed an observational study over a 4-yr period. For each adult patient undergoing a general anesthetic, preoperative patient characteristics, detailed airway physical exam, and airway outcome data were collected. The primary outcome was impossible mask ventilation defined as the inability to exchange air during bag-mask ventilation attempts, despite multiple providers, airway adjuvants, or neuromuscular blockade. Secondary outcomes included the final, definitive airway management technique and direct laryngoscopy view. The incidence of impossible mask ventilation was calculated. Independent (P < 0.05) predictors of impossible mask ventilation were identified by performing a logistic regression full model fit. Over a 4-yr period from 2004 to 2008, 53,041 attempts at mask ventilation were recorded. A total of 77 cases of impossible mask ventilation (0.15%) were observed. Neck radiation changes, male sex, sleep apnea, Mallampati III or IV, and presence of beard were identified as independent predictors. The receiver-operating-characteristic area under the curve for this model was 0.80 +/- 0.03. Nineteen impossible mask ventilation patients (25%) also demonstrated difficult intubation, with 15 being intubated successfully. Twelve patients required an alternative intubation technique, including two surgical airways and two patients who were awakened and underwent successful fiberoptic intubation. Impossible mask ventilation is an infrequent airway event that is associated with difficult intubation. Neck radiation changes represent the most significant clinical predictor of impossible mask ventilation in the patient dataset.

  13. Review of economic evaluations of mask and respirator use for protection against respiratory infection transmission.

    PubMed

    Mukerji, Shohini; MacIntyre, C Raina; Newall, Anthony T

    2015-10-13

    There has been increasing debate surrounding mask and respirator interventions to control respiratory infection transmission in both healthcare and community settings. As decision makers are considering the recommendations they should evaluate how to provide the most efficient protection strategies with minimum costs. The aim of this review is to identify and evaluate the existing economic evaluation literature in this area and to offer advice on how future evaluations on this topic should be conducted. We searched the Scopus database for all literature on economic evaluation of mask or respirator use to control respiratory infection transmission. Reference lists from the identified studies were also manually searched. Seven studies met our inclusion criteria from the initial 806 studies identified by the search strategy and our manual search. Five studies considered interventions for seasonal and/or pandemic influenza, with one also considering SARS (Severe Acute Respiratory Syndrome). The other two studies focussed on tuberculosis transmission control interventions. The settings and methodologies of the studies varied greatly. No low-middle income settings were identified. Only one of the reviewed studies cited clinical evidence to inform their mask/respirator intervention effectiveness parameters. Mask and respirator interventions were generally reported by the study authors to be cost saving or cost-effective when compared to no intervention or other control measures, however the evaluations had important limitations. Given the large cost differential between masks and respirators, there is a need for more comprehensive economic evaluations to compare the relative costs and benefits of these interventions in situations and settings where alternative options are potentially applicable. There are at present insufficient well conducted cost-effectiveness studies to inform decision-makers on the value for money of alternative mask/respirator options.

  14. Psychophysiological responses to masked auditory stimuli.

    PubMed

    Borgeat, F; Elie, R; Chaloult, L; Chabot, R

    1985-02-01

    Psychophysiological responses to masked auditory verbal stimuli of increasing intensities were studied in twenty healthy women. Two experimental sessions corresponding to two stimulation contents (neutral or emotional) were conducted. At each session, two different sets of instructions (attending or not attending to stimuli) were used successively. Verbal stimuli, masked by a 40-dB white noise, were presented to the subject at increasing intensities by increments of 5 dB starting at 0 dB. At each increment, frontal EMG, skin conductance and heart rate were recorded. The data were submitted to analyses of variance and covariance. Psychophysiological responses to stimuli below the thresholds of identification and detection were observed. The instruction not to attend the stimuli modified the patterns of physiological responses. The effect of the affective content of the stimuli on responses was stronger when not attending. The results show the possibility of psychophysiological responses to masked auditory stimuli and suggests that psychophysiological parameters can constitute objective and useful measures for research in auditory subliminal perception.

  15. A Novel Anti-Influenza Copper Oxide Containing Respiratory Face Mask

    PubMed Central

    Borkow, Gadi; Zhou, Steve S.; Page, Tom; Gabbay, Jeffrey

    2010-01-01

    Background Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. Methodology/Principal Findings We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66±0.51 and 6.17±0.37 log10TCID50 of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (≤0.88 log10TCID50), while 4.67±1.35 log10TCID50 were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were ≤0.97±0.01 log10TCID50 and from the control masks 5.03±0.54 log10TCID50. The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Conclusions/Significance Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks

  16. "The Mask Who Wasn't There": Visual Masking Effect with the Perceptual Absence of the Mask

    ERIC Educational Resources Information Center

    Rey, Amandine Eve; Riou, Benoit; Muller, Dominique; Dabic, Stéphanie; Versace, Rémy

    2015-01-01

    Does a visual mask need to be perceptually present to disrupt processing? In the present research, we proposed to explore the link between perceptual and memory mechanisms by demonstrating that a typical sensory phenomenon (visual masking) can be replicated at a memory level. Experiment 1 highlighted an interference effect of a visual mask on the…

  17. Binaural electric-acoustic interactions recorded from the inferior colliculus of Guinea pigs: the effect of masking observed in the central nucleus of the inferior colliculus.

    PubMed

    Noh, Heil; Lee, Dong-Hee

    2012-09-01

    To investigate the electric-acoustic interactions within the inferior colliculus of guinea pigs and to observe how central masking appears in invasive neural recordings of the inferior colliculus (IC). A platinum-iridium wire was inserted to scala tympani through cochleostomy with a depth no greater than 1 mm for intracochlear stimulation of electric pulse train. A 5 mm 100 µm, single-shank, thin-film, penetrating recording probe was inserted perpendicularly to the surface of the IC in the coronal plane at an angle of 30-40° off the parasagittal plane with a depth of 2.0-2.5 mm. The peripheral and central masking effects were compared using electric pulse trains to the left ear and acoustic noise to the left ear (ipsilateral) and to the right ear (contralateral). Binaural acoustic stimuli were presented with different time delays and compared with combined electric and acoustic stimuli. The averaged evoked potentials and total spike numbers were measured using thin-film electrodes inserted into the central nucleus of the IC. Ipsilateral noise had more obvious effects on the electric response than did contralateral noise. Contralateral noise decreased slightly the response amplitude to the electric pulse train stimuli. Immediately after the onset of acoustic noise, the response pattern changed transiently with shorter response intervals. The effects of contralateral noise were evident at the beginning of the continuous noise. The total spike number decreased when the binaural stimuli reached the IC most simultaneously. These results suggest that central masking is quite different from peripheral masking and occurs within the binaural auditory system, and this study showed that the effect of masking could be observed in the IC recording. These effects are more evident and consistent with the psychophysical data from spike number analyses than with the previously reported gross potential data.

  18. Method To Display Data On A Face Mask

    NASA Technical Reports Server (NTRS)

    Moore, Kevin-Duron

    1995-01-01

    Proposed electronic instrument displays information on diver's or firefighter's face mask. Includes mask, prism, electronic readouts, transceiver and control electronics. Mounted at periphery of diver's field of view to provide data on elapsed time, depth, pressure, and temperature. Provides greater safety and convenience to user.

  19. Mask automation: need a revolution in mask makers and equipment industry

    NASA Astrophysics Data System (ADS)

    Moon, Seong-yong; Yu, Sang-yong; Noh, Young-hwa; Son, Ki-jung; Lee, Hyun-Joo; Cho, Han-Ku

    2013-09-01

    As improving device integration for the next generation, high performance and cost down are also required accordingly in semiconductor business. Recently, significant efforts have been given on putting EUV technology into fabrication in order to improve device integration. At the same time, 450mm wafer manufacturing environment has been considered seriously in many ways in order to boost up the productivity. Accordingly, 9-inch mask has been discussed in mask fabrication business recently to support 450mm wafer manufacturing environment successfully. Although introducing 9-inch mask can be crucial for mask industry, multi-beam technology is also expected as another influential turning point to overcome currently the most critical issue in mask industry, electron beam writing time. No matter whether 9-inch mask or multi-beam technology will be employed or not, mask quality and productivity will be the key factors to survive from the device competition. In this paper, the level of facility automation in mask industry is diagnosed and analyzed and the automation guideline is suggested for the next generation.

  20. How color, regularity, and good Gestalt determine backward masking.

    PubMed

    Sayim, Bilge; Manassi, Mauro; Herzog, Michael

    2014-06-18

    The strength of visual backward masking depends on the stimulus onset asynchrony (SOA) between target and mask. Recently, it was shown that the conjoint spatial layout of target and mask is as crucial as SOA. Particularly, masking strength depends on whether target and mask group with each other. The same is true in crowding where the global spatial layout of the flankers and target-flanker grouping determine crowding strength. Here, we presented a vernier target followed by different flanker configurations at varying SOAs. Similar to crowding, masking of a red vernier target was strongly reduced for arrays of 10 green compared with 10 red flanking lines. Unlike crowding, single green lines flanking the red vernier showed strong masking. Irregularly arranged flanking lines yielded stronger masking than did regularly arranged lines, again similar to crowding. While cuboid flankers reduced crowding compared with single lines, this was not the case in masking. We propose that, first, masking is reduced when the flankers are part of a larger spatial structure. Second, spatial factors counteract color differences between the target and the flankers. Third, complex Gestalts, such as cuboids, seem to need longer processing times to show ungrouping effects as observed in crowding. Strong parallels between masking and crowding suggest similar underlying mechanism; however, temporal factors in masking additionally modulate performance, acting as an additional grouping cue. © 2014 ARVO.

  1. EUVL masks: paving the path for commercialization

    NASA Astrophysics Data System (ADS)

    Mangat, Pawitter J. S.; Hector, Scott D.

    2001-09-01

    Optical projection lithography has been the principal vehicle of semiconductor manufacturing for more than 20 years and is marching aggressively to satisfy the needs of semiconductor manufacturers for 100nm devices. However, the complexity of optical lithography continues to increase as wavelength reduction continues to 157nm. Extreme Ultraviolet Lithography (EUVL), with wavelength from 13-14 nm, is evolving as a leading next generation lithography option for semiconductor industry to stay on the path laid by Moore's Law. Masks are a critical part of the success of any technology and are considered to be high risk both for optical lithography and NGL technologies for sub-100nm lithography. Two key areas of EUV mask fabrication are reflective multilayer deposition and absorber patterning. In the case of reflective multilayers, delivering defect free multilayers for mask blanks is the biggest challenge. Defect mitigation is being explored as a possible option to smooth the multilayer defects in addition to optimization of the deposition process to reduce defect density. The mask patterning process needs focus on the defect-free absorber stack patterning process, mask cleaning, inspection and repair. In addition, there is considerable effort to understand by simulations, the defect printability, thermal and mechanical distortions, and non-telecentric illumination, to mention a few. To protect the finished mask from defects added during use, a removable pellicle strategy combined with thermophoretic protection during exposure is being developed. Recent migration to square form factor using low thermal expansion material (LTEM) is advantageous as historical developments in optical masks can be applied to EUV mask patterning. This paper addresses recent developments in the EUV mask patterning and highlights critical manufacturing process controls needed to fabricate defect-free full field masks with CD and image placement specifications for sub-70nm node lithography. No

  2. Rescue therapy by switching to total face mask after failure of face mask-delivered noninvasive ventilation in do-not-intubate patients in acute respiratory failure.

    PubMed

    Lemyze, Malcolm; Mallat, Jihad; Nigeon, Olivier; Barrailler, Stéphanie; Pepy, Florent; Gasan, Gaëlle; Vangrunderbeeck, Nicolas; Grosset, Philippe; Tronchon, Laurent; Thevenin, Didier

    2013-02-01

    To evaluate the impact of switching to total face mask in cases where face mask-delivered noninvasive mechanical ventilation has already failed in do-not-intubate patients in acute respiratory failure. Prospective observational study in an ICU and a respiratory stepdown unit over a 12-month study period. Switching to total face mask, which covers the entire face, when noninvasive mechanical ventilation using facial mask (oronasal mask) failed to reverse acute respiratory failure. Seventy-four patients with a do-not-intubate order and treated by noninvasive mechanical ventilation for acute respiratory failure. Failure of face mask-delivered noninvasive mechanical ventilation was associated with a three-fold increase in in-hospital mortality (36% vs. 10.5%; p = 0.009). Nevertheless, 23 out of 36 patients (64%) in whom face mask-delivered noninvasive mechanical ventilation failed to reverse acute respiratory failure and, therefore, switched to total face mask survived hospital discharge. Reasons for switching from facial mask to total face mask included refractory hypercapnic acute respiratory failure (n = 24, 66.7%), painful skin breakdown or facial mask intolerance (n = 11, 30%), and refractory hypoxemia (n = 1, 2.7%). In the 24 patients switched from facial mask to total face mask because of refractory hypercapnia, encephalopathy score (3 [3-4] vs. 2 [2-3]; p < 0.0001), PaCO2 (87 ± 25 mm Hg vs. 70 ± 17 mm Hg; p < 0.0001), and pH (7.24 ± 0.1 vs. 7.32 ± 0.09; p < 0.0001) significantly improved after 2 hrs of total face mask-delivered noninvasive ventilation. Patients switched early to total face mask (in the first 12 hrs) developed less pressure sores (n = 5, 24% vs. n = 13, 87%; p = 0.0002), despite greater length of noninvasive mechanical ventilation within the first 48 hrs (44 hrs vs. 34 hrs; p = 0.05) and less protective dressings (n = 2, 9.5% vs. n = 8, 53.3%; p = 0.007). The optimal cutoff value for face mask-delivered noninvasive mechanical ventilation

  3. Masked polycythaemia vera: presenting features, response to treatment and clinical outcomes.

    PubMed

    Alvarez-Larrán, Alberto; Angona, Anna; Ancochea, Agueda; García-Pallarols, Francesc; Fernández, Concepción; Longarón, Raquel; Bellosillo, Beatriz; Besses, Carlos

    2016-01-01

    Masked polycythaemia vera (PV) has been proposed as a new entity with poorer outcome than overt PV. In this study, the initial clinical and laboratory characteristics, response to treatment and outcome of masked and overt PV were compared using red cell mass and haemoglobin or haematocrit levels for the distinction between both entities. Sixty-eight of 151 PV patients (45%) were classified as masked PV according to World Health Organisation diagnostic criteria, whereas 16 (11%) were classified as masked PV using the British Committee for Standards in Haematology (BCSH). In comparison with overt PV, a higher platelet count and a lower JAK2V617F allele burden at diagnosis were observed in masked PV. Patients with masked PV needed lower phlebotomies and responded faster to hydroxcarbamide than those with overt PV. Complete haematological response was more frequently achieved in masked than in overt PV (79% vs. 58%, P = 0.001). There were no significant differences in the duration of haematological response, the rate of resistance or intolerance to hydroxycarbamide and the probability of molecular response according to type of PV (masked vs. overt). Overall survival, rate of thrombosis and major bleeding, and probability of transformation was superimposable among patients with masked and overt PV. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial.

    PubMed

    Oto, Jun; Li, Qian; Kimball, William R; Wang, Jingping; Sabouri, Abdolnabi S; Harrell, Priscilla G; Kacmarek, Robert M; Jiang, Yandong

    2013-12-23

    Upper airway obstruction (UAO) is a major problem in unconscious subjects, making full face mask ventilation difficult. The mechanism of UAO in unconscious subjects shares many similarities with that of obstructive sleep apnea (OSA), especially the hypotonic upper airway seen during rapid eye movement sleep. Continuous positive airway pressure (CPAP) via nasal mask is more effective at maintaining airway patency than a full face mask in patients with OSA. We hypothesized that CPAP via nasal mask and ventilation (nCPAP) would be more effective than full face mask CPAP and ventilation (FmCPAP) for unconscious subjects, and we tested our hypothesis during induction of general anesthesia for elective surgery. In total, 73 adult subjects requiring general anesthesia were randomly assigned to one of four groups: nCPAP P0, nCPAP P5, FmCPAP P0, and FmCPAP P5, where P0 and P5 represent positive end-expiratory pressure (PEEP) 0 and 5 cm H2O applied prior to induction. After apnea, ventilation was initiated with pressure control ventilation at a peak inspiratory pressure over PEEP (PIP/PEEP) of 20/0, then 20/5, and finally 20/10 cm H2O, each applied for 1 min. At each pressure setting, expired tidal volume (Vte) was calculated by using a plethysmograph device. The rate of effective tidal volume (Vte > estimated anatomical dead space) was higher (87.9% vs. 21.9%; P<0.01) and the median Vte was larger (6.9 vs. 0 mL/kg; P<0.01) with nCPAP than with FmCPAP. Application of CPAP prior to induction of general anesthesia did not affect Vte in either approach (nCPAP pre- vs. post-; 7.9 vs. 5.8 mL/kg, P = 0.07) (FmCPAP pre- vs. post-; 0 vs. 0 mL/kg, P = 0.11). nCPAP produced more effective tidal volume than FmCPAP in unconscious subjects. ClinicalTrials.gov identifier: NCT01524614.

  5. Impact of different nasal masks on CPAP therapy for obstructive sleep apnea: a randomized comparative trial.

    PubMed

    Neuzeret, Pierre-Charles; Morin, Laurent

    2017-11-01

    Patient interface is important for the success of continuous positive airway pressure (CPAP), but few trials have examined the influence of mask choice on CPAP adherence. To compare the impact of different nasal masks on CPAP in patients with newly-diagnosed obstructive sleep apnea (OSA). OSA patients were randomized in a 2:3 ratio to receive CPAP via different first-line nasal masks: ResMed Mirage FX® (MFX) or control mask (Fisher & Paykel Zest ® , HC407 ® or Philips EasyLife ® ). Mask acceptance, CPAP compliance and Home Care Provider (HCP) interventions were compared between groups after 3 months of CPAP therapy using modified intent-to-treat (mITT; after exclusion of patients with mouth leaks during CPAP initiation) and on-treatment (OT; CPAP adherent) analyses. Of 285 randomized patients, 90 requiring a full-face mask were excluded, leaving 195 and 151 in the mITT and OT analyses, respectively. Mask acceptance rate was higher in the MFX versus control group (mITT: 79% vs 68%, P = 0.067; OT: 90% vs 76%, P = 0.022). CPAP compliance was higher (5.9 ± 1.8 vs 5.1 ± 1.6 h/night, P = 0.011) and nasal mask issue-related HCP visits lower (3% vs 17%, P = 0.006) in the MFX group. Nasal mask failures due to mask discomfort (5% vs 1%) or unintentional leakage (5% vs 0%) were higher in control vs MFX group. Mask acceptance was significantly associated with fewer mask leaks (P = 0.002) and higher pressure therapy (P = 0.042). This study highlights differences between nasal masks for CPAP delivery and shows that initial mask selection can influence adherence and healthcare utilization during CPAP. © 2016 ResMed Germany Inc. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  6. Observational studies are complementary to randomized controlled trials.

    PubMed

    Grootendorst, Diana C; Jager, Kitty J; Zoccali, Carmine; Dekker, Friedo W

    2010-01-01

    Randomized controlled trials (RCTs) are considered the gold standard study design to investigate the effect of health interventions, including treatment. However, in some situations, it may be unnecessary, inappropriate, impossible, or inadequate to perform an RCT. In these special situations, well-designed observational studies, including cohort and case-control studies, may provide an alternative to doing nothing in order to obtain estimates of treatment effect. It should be noted that such studies should be performed with caution and correctly. The aims of this review are (1) to explain why RCTs are considered the optimal study design to evaluate treatment effects, (2) to describe the situations in which an RCT is not possible and observational studies are an adequate alternative, and (3) to explain when randomization is not needed and can be approximated in observational studies. Examples from the nephrology literature are used for illustration. Copyright 2009 S. Karger AG, Basel.

  7. Does conflict control occur without awareness? Evidence from an ERP study.

    PubMed

    Wang, Baoxi; Xiang, Ling; Li, Juan

    2013-01-15

    The relationship between conflict control and awareness has attracted extensive interest. Although researchers have investigated the relationship between response conflict and awareness, it still remains unclear whether stimulus conflict can occur outside of awareness. In addition, previous studies on the role of awareness in conflict control have ignored the fact that conflict control includes both conflict detection and resolution. A modified version of the flanker task was used to manipulate stimulus and response conflicts under both masked and unmasked conditions. The masked condition elicited a sequence of distinct event-related potential components that were also observed in the unmasked condition. N2 amplitudes presented the following pattern: incongruent-eligible>incongruent-ineligible>congruent, they did not show any difference under the masked and unmasked conditions, suggesting that detection of stimulus-related conflict revealed by the comparison between incongruent-ineligible and congruent trials, and response-related conflict revealed by the comparison between incongruent-eligible and incongruent-ineligible trials can occur in the absence of awareness, and unconscious conflict detection might involve the same neural network employed for conscious conflict detection. Late positive component (LPC) amplitudes also presented as incongruent-eligible>incongruent-ineligible>congruent at CPz and Pz, irrespective of conscious awareness. However, LPC amplitudes under the masked condition were markedly reduced compared to unmasked trials. These LPC findings suggest that stimulus- and response-related conflict resolution can occur in the absence of awareness; furthermore, unconscious conflict resolution might involve a weaker cognitive control network compared to conscious conflict resolution. These findings have important implications for the theories concerning the relationship between cognitive control and awareness. Copyright © 2012 Elsevier B.V. All rights

  8. Integration of mask and silicon metrology in DFM

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Sugiyama, Akiyuki; Toyoda, Yasutaka

    2009-03-01

    We have developed a highly integrated method of mask and silicon metrology. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. We have inspected the high accuracy, stability and reproducibility in the experiments of integration. The accuracy is comparable with that of the mask and silicon CD-SEM metrology. In this report, we introduce the experimental results and the application. As shrinkage of design rule for semiconductor device advances, OPC (Optical Proximity Correction) goes aggressively dense in RET (Resolution Enhancement Technology). However, from the view point of DFM (Design for Manufacturability), the cost of data process for advanced MDP (Mask Data Preparation) and mask producing is a problem. Such trade-off between RET and mask producing is a big issue in semiconductor market especially in mask business. Seeing silicon device production process, information sharing is not completely organized between design section and production section. Design data created with OPC and MDP should be linked to process control on production. But design data and process control data are optimized independently. Thus, we provided a solution of DFM: advanced integration of mask metrology and silicon metrology. The system we propose here is composed of followings. 1) Design based recipe creation: Specify patterns on the design data for metrology. This step is fully automated since they are interfaced with hot spot coordinate information detected by various verification methods. 2) Design based image acquisition: Acquire the images of mask and silicon automatically by a recipe based on the pattern design of CD-SEM.It is a robust automated step because a wide range of design data is used for the image acquisition. 3) Contour profiling and GDS data generation: An image profiling process is applied to the acquired image based

  9. Alternating phase-shifted mask for logic gate levels, design, and mask manufacturing

    NASA Astrophysics Data System (ADS)

    Liebmann, Lars W.; Graur, Ioana C.; Leipold, William C.; Oberschmidt, James M.; O'Grady, David S.; Regaill, Denis

    1999-07-01

    While the benefits of alternating phase shifted masks in improving lithographic process windows at increased resolution are well known throughout the lithography community, broad implementation of this potentially powerful technique has been slow due to the inherent complexity of the layout design and mask manufacturing process. This paper will review a project undertaken at IBM's Semiconductor Research and Development Center and Mask Manufacturing and Development facility to understand the technical and logistical issues associated with the application of alternating phase shifted mask technology to the gate level of a full microprocessor chip. The work presented here depicts an important milestone toward integration of alternating phase shifted masks into the manufacturing process by demonstrating an automated design solution and yielding a functional alternating phase shifted mask. The design conversion of the microprocessor gate level to a conjugate twin shifter alternating phase shift layout was accomplished with IBM's internal design system that automatically scaled the design, added required phase regions, and resolved phase conflicts. The subsequent fabrication of a nearly defect free phase shifted mask, as verified by SEM based die to die inspection, highlights the maturity of the alternating phase shifted mask manufacturing process in IBM's internal mask facility. Well defined and recognized challenges in mask inspection and repair remain and the layout of alternating phase shifted masks present a design and data preparation overhead, but the data presented here demonstrate the feasibility of designing and building manufacturing quality alternating phase shifted masks for the gate level of a microprocessor.

  10. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    PubMed

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  11. EUV mask manufacturing readiness in the merchant mask industry

    NASA Astrophysics Data System (ADS)

    Green, Michael; Choi, Yohan; Ham, Young; Kamberian, Henry; Progler, Chris; Tseng, Shih-En; Chiou, Tsann-Bim; Miyazaki, Junji; Lammers, Ad; Chen, Alek

    2017-10-01

    As nodes progress into the 7nm and below regime, extreme ultraviolet lithography (EUVL) becomes critical for all industry participants interested in remaining at the leading edge. One key cost driver for EUV in the supply chain is the reflective EUV mask. As of today, the relatively few end users of EUV consist primarily of integrated device manufactures (IDMs) and foundries that have internal (captive) mask manufacturing capability. At the same time, strong and early participation in EUV by the merchant mask industry should bring value to these chip makers, aiding the wide-scale adoption of EUV in the future. For this, merchants need access to high quality, representative test vehicles to develop and validate their own processes. This business circumstance provides the motivation for merchants to form Joint Development Partnerships (JDPs) with IDMs, foundries, Original Equipment Manufacturers (OEMs) and other members of the EUV supplier ecosystem that leverage complementary strengths. In this paper, we will show how, through a collaborative supplier JDP model between a merchant and OEM, a novel, test chip driven strategy is applied to guide and validate mask level process development. We demonstrate how an EUV test vehicle (TV) is generated for mask process characterization in advance of receiving chip maker-specific designs. We utilize the TV to carry out mask process "stress testing" to define process boundary conditions which can be used to create Mask Rule Check (MRC) rules as well as serve as baseline conditions for future process improvement. We utilize Advanced Mask Characterization (AMC) techniques to understand process capability on designs of varying complexity that include EUV OPC models with and without sub-resolution assist features (SRAFs). Through these collaborations, we demonstrate ways to develop EUV processes and reduce implementation risks for eventual mass production. By reducing these risks, we hope to expand access to EUV mask capability for

  12. Development of binary image masks for TPF-C and ground-based AO coronagraphs

    NASA Astrophysics Data System (ADS)

    Ge, Jian; Crepp, Justin; Vanden Heuvel, Andrew; Miller, Shane; McDavitt, Dan; Kravchenko, Ivan; Kuchner, Marc

    2006-06-01

    We report progress on the development of precision binary notch-filter focal plane coronagraphic masks for directly imaging Earth-like planets at visible wavelengths with the Terrestrial Planet Finder Coronagraph (TPF-C), and substellar companions at near infrared wavelengths from the ground with coronagraphs coupled to high-order adaptive optics (AO) systems. Our recent theoretical studies show that 8th-order image masks (Kuchner, Crepp & Ge 2005, KCG05) are capable of achieving unlimited dynamic range in an ideal optical system, while simultaneously remaining relatively insensitive to low-spatial-frequency optical aberrations, such as tip/tilt errors, defocus, coma, astigmatism, etc. These features offer a suite of advantages for the TPF-C by relaxing many control and stability requirements, and can also provide resistance to common practical problems associated with ground-based observations; for example, telescope flexure and low-order errors left uncorrected by the AO system due to wavefront sensor-deformable mirror lag time can leak light at significant levels. Our recent lab experiments show that prototype image masks can generate contrast levels on the order of 2x10 -6 at 3 λ/D and 6x10 -7 at 10 λ/D without deformable mirror correction using monochromatic light (Crepp et al. 2006), and that this contrast is limited primarily by light scattered by imperfections in the optics and extra diffraction created by mask construction errors. These experiments also indicate that the tilt and defocus sensitivities of high-order masks follow the theoretical predictions of Shaklan and Green 2005. In this paper, we discuss these topics as well as review our progress on developing techniques for fabricating a new series of image masks that are "free-standing", as such construction designs may alleviate some of the (mostly chromatic) problems associated with masks that rely on glass substrates for mechanical support. Finally, results obtained from our AO coronagraph

  13. A randomised controlled trial on the effect of mask choice on residual respiratory events with continuous positive airway pressure treatment.

    PubMed

    Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C

    2014-06-01

    It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to < 5/h on a titration study. However, it was not previously known whether switching from one CPAP mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, p<0.001). All 14 subjects had a higher residual AHI with the oronasal versus nasal mask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of < 5/h in the laboratory. A higher residual AHI was seen in all patients with the use of an oronasal mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Hyper-realistic face masks: a new challenge in person identification.

    PubMed

    Sanders, Jet Gabrielle; Ueda, Yoshiyuki; Minemoto, Kazusa; Noyes, Eilidh; Yoshikawa, Sakiko; Jenkins, Rob

    2017-01-01

    We often identify people using face images. This is true in occupational settings such as passport control as well as in everyday social environments. Mapping between images and identities assumes that facial appearance is stable within certain bounds. For example, a person's apparent age, gender and ethnicity change slowly, if at all. It also assumes that deliberate changes beyond these bounds (i.e., disguises) would be easy to spot. Hyper-realistic face masks overturn these assumptions by allowing the wearer to look like an entirely different person. If unnoticed, these masks break the link between facial appearance and personal identity, with clear implications for applied face recognition. However, to date, no one has assessed the realism of these masks, or specified conditions under which they may be accepted as real faces. Herein, we examined incidental detection of unexpected but attended hyper-realistic masks in both photographic and live presentations. Experiment 1 (UK; n = 60) revealed no evidence for overt detection of hyper-realistic masks among real face photos, and little evidence of covert detection. Experiment 2 (Japan; n = 60) extended these findings to different masks, mask-wearers and participant pools. In Experiment 3 (UK and Japan; n = 407), passers-by failed to notice that a live confederate was wearing a hyper-realistic mask and showed limited evidence of covert detection, even at close viewing distance (5 vs. 20 m). Across all of these studies, viewers accepted hyper-realistic masks as real faces. Specific countermeasures will be required if detection rates are to be improved.

  15. In-die mask registration measurement on 28nm-node and beyond

    NASA Astrophysics Data System (ADS)

    Chen, Shen Hung; Cheng, Yung Feng; Chen, Ming Jui

    2013-09-01

    As semiconductor go to smaller node, the critical dimension (CD) of process become more and more small. For lithography, RET (Resolution Enhancement Technology) applications can be used for wafer printing of smaller CD/pitch on 28nm node and beyond. SMO (Source Mask Optimization), DPT (Double Patterning Technology) and SADP (Self-Align Double Patterning) can provide lower k1 value for lithography. In another way, image placement error and overlay control also become more and more important for smaller chip size (advanced node). Mask registration (image placement error) and mask overlay are important factors to affect wafer overlay control/performance especially for DPT or SADP. In traditional method, the designed registration marks (cross type, square type) with larger CD were put into scribe-line of mask frame for registration and overlay measurement. However, these patterns are far way from real patterns. It does not show the registration of real pattern directly and is not a convincing method. In this study, the in-die (in-chip) registration measurement is introduced. We extract the dummy patterns that are close to main pattern from post-OPC (Optical Proximity Correction) gds by our desired rule and choose the patterns that distribute over whole mask uniformly. The convergence test shows 100 points measurement has a reliable result.

  16. Mask characterization for critical dimension uniformity budget breakdown in advanced extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho

    2013-04-01

    As the International Technology Roadmap for Semiconductors critical dimension uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. We will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for advanced extreme ultraviolet (EUV) lithography with 1D (dense lines) and 2D (dense contacts) feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CDs and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples. Mask stack reflectivity variations should also be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We also observed mask error enhancement factor (MEEF) through field fingerprints in the studied EUV cases. Variations of MEEF may play a role towards the total intrafield CDU and may need to be taken into account for EUV lithography. We characterized MEEF-through-field for the reviewed features, with results herein, but further analysis of this phenomenon is required. This comprehensive approach to quantifying the mask part of

  17. Advanced refractory-metal and process technology for the fabrication of x-ray masks

    NASA Astrophysics Data System (ADS)

    Brooks, Cameron J.; Racette, Kenneth C.; Lercel, Michael J.; Powers, Lynn A.; Benoit, Douglas E.

    1999-06-01

    This paper provides an in-depth report of the advanced materials and process technology being developed for x-ray mask manufacturing at IBM. Masks using diamond membranes as replacement for silicon carbide are currently being fabricated. Alternate tantalum-based absorbers, such as tantalum boron, which offer improved etch resolution and critical dimension control, as well as higher x-ray absorption, are also being investigated. In addition to the absorber studies, the development of conductive chromium- based hard-mask films to replace the current silicon oxynitride layer is being explored. The progress of this advanced-materials work, which includes significant enhancements to x-ray mask image-placement performance, will be outlined.

  18. Universal Mask Usage for Reduction of Respiratory Viral Infections After Stem Cell Transplant: A Prospective Trial

    PubMed Central

    Sung, Anthony D.; Sung, Julia A. M.; Thomas, Samantha; Hyslop, Terry; Gasparetto, Cristina; Long, Gwynn; Rizzieri, David; Sullivan, Keith M.; Corbet, Kelly; Broadwater, Gloria; Chao, Nelson J.; Horwitz, Mitchell E.

    2016-01-01

    Background. Respiratory viral infections (RVIs) are frequent complications of hematopoietic stem cell transplant (HSCT). Surgical masks are a simple and inexpensive intervention that may reduce nosocomial spread. Methods. In this prospective single-center study, we instituted a universal surgical mask policy requiring all individuals with direct contact with HSCT patients to wear a surgical mask, regardless of symptoms or season. The primary endpoint was the incidence of RVIs in the mask period (2010–2014) compared with the premask period (2003–2009). Results. RVIs decreased from 10.3% (95/920 patients) in the premask period to 4.4% (40/911) in the mask period (P < .001). Significant decreases occurred after both allogeneic (64/378 [16.9%] to 24/289 [8.3%], P = .001) and autologous (31/542 [5.7%] to 16/622 [2.6%], P = .007) transplants. After adjusting for multiple covariates including season and year in a segmented longitudinal analysis, the decrease in RVIs remained significant, with risk of RVI of 0.4 in patients in the mask group compared with the premask group (0.19–0.85, P = .02). In contrast, no decrease was observed during this same period in an adjacent hematologic malignancy unit, which followed the same infection control practices except for the mask policy. The majority of this decrease was in parainfluenza virus 3 (PIV3) (8.3% to 2.2%, P < .001). Conclusions. Requiring all individuals with direct patient contact to wear a surgical mask is associated with a reduction in RVIs, particularly PIV3, during the most vulnerable period following HSCT. PMID:27481873

  19. Surgical Face Masks Worn by Patients with Multidrug-Resistant Tuberculosis

    PubMed Central

    Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A.; van der Walt, Martie; Nardell, Edward A.

    2012-01-01

    Rationale: Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. Objectives: We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Methods: Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Measurements and Main Results: Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68–85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31–51%), representing a 56% (95% CI, 33–70.5%) decreased risk of TB transmission when patients used masks. Conclusions: Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients. PMID:22323300

  20. Clean induced feature CD shift of EUV mask

    NASA Astrophysics Data System (ADS)

    Nesládek, Pavel; Schedel, Thorsten; Bender, Markus

    2016-05-01

    considering, that the tools for CD measurement at the EUV mask are identical as for optical mask. There is one aspect influencing the CD shift, which demands attention. The mask composition of the EUV mask is significantly different from the optical mask. More precisely there are 2 materials influencing the estimated CD in case of EUV mask, whereas there is one material only in case of optical masks, in first approximation. For optical masks, the CD changes can be attributed to modification of the absorber/ARC layer, as the quartz substrate can be hardly modified by the wet process. For EUV Masks chemical modification of the Ru capping layer - thinning, oxidization etc. are rather more probable and we need to take into account, how this effects can influence the CD measurement process. CD changes measured can be interpreted as either change in the feature size, or modification of the chemical nature of both absorber/ARC layer stack and the Ru capping layer. In our work we try to separate the effect of absorber and Ru/capping layer on the CD shift observed and propose independent way of estimation both parameters.

  1. Enhancement in Informational Masking

    ERIC Educational Resources Information Center

    Cao, Xiang; Richards, Virginia M.

    2012-01-01

    Purpose: The ability to detect a tone added to a random masker improves when a preview of the masker is provided. In 2 experiments, the authors explored the role that perceptual organization plays in this release from masking. Method: Detection thresholds were measured in informational masking studies. The maskers were drawn at random prior to…

  2. Contrast masking in strabismic amblyopia: attenuation, noise, interocular suppression and binocular summation.

    PubMed

    Baker, Daniel H; Meese, Tim S; Hess, Robert F

    2008-07-01

    To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrast discrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224-1243.] was 'lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.

  3. Applying Triple-Matrix Masking for Privacy Preserving Data Collection and Sharing in HIV Studies.

    PubMed

    Pei, Qinglin; Chen, Shigang; Xiao, Yao; Wu, Samuel S

    2016-01-01

    Many HIV research projects are plagued by the high missing rate of selfreported information during data collection. Also, due to the sensitive nature of the HIV research data, privacy protection is always a concern for data sharing in HIV studies. This paper applies a data masking approach, called triple-matrix masking [1], to the context of HIV research for ensuring privacy protection during the process of data collection and data sharing. Using a set of generated HIV patient data, we show step by step how the data are randomly transformed (masked) before leaving the patients' individual data collection device (which ensures that nobody sees the actual data) and how the masked data are further transformed by a masking service provider and a data collector. We demonstrate that the masked data retain statistical utility of the original data, yielding the exactly same inference results in the planned logistic regression on the effect of age on the adherence to antiretroviral therapy and in the Cox proportional hazard model for the age effect on time to viral load suppression. Privacy-preserving data collection method may help resolve the privacy protection issue in HIV research. The individual sensitive data can be completely hidden while the same inference results can still be obtained from the masked data, with the use of common statistical analysis methods.

  4. Propagation of resist heating mask error to wafer level

    NASA Astrophysics Data System (ADS)

    Babin, S. V.; Karklin, Linard

    2006-10-01

    As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the

  5. Disposable surgical face masks for preventing surgical wound infection in clean surgery.

    PubMed

    Lipp, Allyson; Edwards, Peggy

    2014-02-17

    Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. To determine whether disposable surgical face masks worn by the surgical team during clean surgery prevent postoperative surgical wound infection. We searched The Cochrane Wounds Group Specialised Register on 23 October 2013; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. Randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing the use of disposable surgical masks with the use of no mask. Two review authors extracted data independently. Three trials were included, involving a total of 2113 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  6. Treatment of allergic rhinitis using mobile technology with real-world data: The MASK observational pilot study.

    PubMed

    Bousquet, J; Devillier, P; Arnavielhe, S; Bedbrook, A; Alexis-Alexandre, G; van Eerd, M; Murray, R; Canonica, G W; Illario, M; Menditto, E; Passalacqua, G; Stellato, C; Triggiani, M; Carreiro-Martins, P; Fonseca, J; Morais Almeida, M; Nogueira-Silva, L; Pereira, A M; Todo Bom, A; Bosse, I; Caimmi, D; Demoly, P; Fontaine, J F; Just, J; Onorato, G L; Kowalski, M L; Kuna, P; Samolinski, B; Anto, J M; Mullol, J; Valero, A; Tomazic, P V; Bergmann, K C; Keil, T; Klimek, L; Mösges, R; Shamai, S; Zuberbier, T; Murphy, E; McDowall, P; Price, D; Ryan, D; Sheikh, A; Chavannes, N H; Fokkens, W J; Kvedariene, V; Valiulis, A; Bachert, C; Hellings, P W; Kull, I; Melen, E; Wickman, M; Bindslev-Jensen, C; Eller, E; Haahtela, T; Papadopoulos, N G; Annesi-Maesano, I; Bewick, M; Bosnic-Anticevich, S; Cruz, A A; De Vries, G; Gemicioglu, B; Larenas-Linnemann, D; Laune, D; Mathieu-Dupas, E; O'Hehir, R E; Pfaar, O; Portejoie, F; Siroux, V; Spranger, O; Valovirta, E; VandenPlas, O; Yorgancioglu, A

    2018-01-15

    Large observational implementation studies are needed to triangulate the findings from randomized control trials as they reflect "real-world" everyday practice. In a pilot study, we attempted to provide additional and complementary insights on the real-life treatment of allergic rhinitis (AR) using mobile technology. A mobile phone app (Allergy Diary, freely available in Google Play and Apple App stores) collects the data of daily visual analog scales (VAS) for (i) overall allergic symptoms, (ii) nasal, ocular, and asthma symptoms, (iii) work, as well as (iv) medication use using a treatment scroll list including all medications (prescribed and over the counter (OTC)) for rhinitis customized for 15 countries. A total of 2871 users filled in 17 091 days of VAS in 2015 and 2016. Medications were reported for 9634 days. The assessment of days appeared to be more informative than the course of the treatment as, in real life, patients do not necessarily use treatment on a daily basis; rather, they appear to increase treatment use with the loss of symptom control. The Allergy Diary allowed differentiation between treatments within or between classes (intranasal corticosteroid use containing medications and oral H1-antihistamines). The control of days differed between no [best control], single, or multiple treatments (worst control). This study confirms the usefulness of the Allergy Diary in accessing and assessing everyday use and practice in AR. This pilot observational study uses a very simple assessment (VAS) on a mobile phone, shows novel findings, and generates new hypotheses. © 2018 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  7. Foul tip impact attenuation of baseball catcher masks using head impact metrics

    PubMed Central

    White, Terrance R.; Cutcliffe, Hattie C.; Shridharani, Jay K.; Wood, Garrett W.; Bass, Cameron R.

    2018-01-01

    Currently, no scientific consensus exists on the relative safety of catcher mask styles and materials. Due to differences in mass and material properties, the style and material of a catcher mask influences the impact metrics observed during simulated foul ball impacts. The catcher surrogate was a Hybrid III head and neck equipped with a six degree of freedom sensor package to obtain linear accelerations and angular rates. Four mask styles were impacted using an air cannon for six 30 m/s and six 35 m/s impacts to the nasion. To quantify impact severity, the metrics peak linear acceleration, peak angular acceleration, Head Injury Criterion, Head Impact Power, and Gadd Severity Index were used. An Analysis of Covariance and a Tukey’s HSD Test were conducted to compare the least squares mean between masks for each head injury metric. For each injury metric a P-Value less than 0.05 was found indicating a significant difference in mask performance. Tukey’s HSD test found for each metric, the traditional style titanium mask fell in the lowest performance category while the hockey style mask was in the highest performance category. Limitations of this study prevented a direct correlation from mask testing performance to mild traumatic brain injury. PMID:29856814

  8. 2013 mask industry survey

    NASA Astrophysics Data System (ADS)

    Malloy, Matt

    2013-09-01

    A comprehensive survey was sent to merchant and captive mask shops to gather information about the mask industry as an objective assessment of its overall condition. 2013 marks the 12th consecutive year for this process. Historical topics including general mask profile, mask processing, data and write time, yield and yield loss, delivery times, maintenance, and returns were included and new topics were added. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. While each year's survey includes minor updates based on feedback from past years and the need to collect additional data on key topics, the bulk of the survey and reporting structure have remained relatively constant. A series of improvements is being phased in beginning in 2013 to add value to a wider audience, while at the same time retaining the historical content required for trend analyses of the traditional metrics. Additions in 2013 include topics such as top challenges, future concerns, and additional details in key aspects of mask masking, such as the number of masks per mask set per ground rule, minimum mask resolution shipped, and yield by ground rule. These expansions beyond the historical topics are aimed at identifying common issues, gaps, and needs. They will also provide a better understanding of real-life mask requirements and capabilities for comparison to the International Technology Roadmap for Semiconductors (ITRS).

  9. Masked response priming in expert typists.

    PubMed

    Heinemann, Alexander; Kiesel, Andrea; Pohl, Carsten; Kunde, Wilfried

    2010-03-01

    In masked priming tasks responses are usually faster when prime and target require identical rather than different responses. Previous research has extensively manipulated the nature and number of response-affording stimuli. However, little is known about the constraints of masked priming regarding the nature and number of response alternatives. The present study explored the limits of masked priming in a six-choice reaction time task, where responses from different fingers of both hands were required. We studied participants that were either experts for the type of response (skilled typists) or novices. Masked primes facilitated responding to targets that required the same response, responses with a different finger of the same hand, and with a homologous finger of the other hand. These effects were modulated by expertise. The results show that masked primes facilitate responding especially for experts in the S-R mapping and with increasing similarity of primed and required response.

  10. Masked priming effect reflects evidence accumulated by the prime.

    PubMed

    Kinoshita, Sachiko; Norris, Dennis

    2010-01-01

    In the same-different match task, masked priming is observed with the same responses but not different responses. Norris and Kinoshita's (2008) Bayesian reader account of masked priming explains this pattern based on the same principle as that explaining the absence of priming for nonwords in the lexical decision task. The pattern of priming follows from the way the model makes optimal decisions in the two tasks; priming does not depend on first activating the prime and then the target. An alternative explanation is in terms of a bias towards responding "same" that exactly counters the facilitatory effect of lexical access. The present study tested these two views by varying both the degree to which the prime predicts the response and the visibility of the prime. Unmasked primes produced effects expected from the view that priming is influenced by the degree to which the prime predicts the response. In contrast, with masked primes, the size of priming for the same response was completely unaffected by predictability. These results rule out response bias as an explanation of the absence of masked priming for different responses and, in turn, indicate that masked priming is not a consequence of automatic lexical access of the prime.

  11. EUVL mask patterning with blanks from commercial suppliers

    NASA Astrophysics Data System (ADS)

    Yan, Pei-Yang; Zhang, Guojing; Nagpal, Rajesh; Shu, Emily Y.; Li, Chaoyang; Qu, Ping; Chen, Frederick T.

    2004-12-01

    Extreme Ultraviolet Lithography (EUVL) reflective mask blank development includes low thermal expansion material fabrication, mask substrate finishing, reflective multi-layer (ML) and capping layer deposition, buffer (optional)/absorber stack deposition, EUV specific metrology, and ML defect inspection. In the past, we have obtained blanks deposited with various layer stacks from several vendors. Some of them are not commercial suppliers. As a result, the blank and patterned mask qualities are difficult to maintain and improve. In this paper we will present the evaluation results of the EUVL mask pattering processes with the complete EUVL mask blanks supplied by the commercial blank supplier. The EUVL mask blanks used in this study consist of either quartz or ULE substrates which is a type of low thermal expansion material (LTEM), 40 pairs of molybdenum/silicon (Mo/Si) ML layer, thin ruthenium (Ru) capping layer, tantalum boron nitride (TaBN) absorber, and chrome (Cr) backside coating. No buffer layer is used. Our study includes the EUVL mask blank characterization, patterned EUVL mask characterization, and the final patterned EUVL mask flatness evaluation.

  12. Abnormal auditory forward masking pattern in the brainstem response of individuals with Asperger syndrome

    PubMed Central

    Källstrand, Johan; Olsson, Olle; Nehlstedt, Sara Fristedt; Sköld, Mia Ling; Nielzén, Sören

    2010-01-01

    Abnormal auditory information processing has been reported in individuals with autism spectrum disorders (ASD). In the present study auditory processing was investigated by recording auditory brainstem responses (ABRs) elicited by forward masking in adults diagnosed with Asperger syndrome (AS). Sixteen AS subjects were included in the forward masking experiment and compared to three control groups consisting of healthy individuals (n = 16), schizophrenic patients (n = 16) and attention deficit hyperactivity disorder patients (n = 16), respectively, of matching age and gender. The results showed that the AS subjects exhibited abnormally low activity in the early part of their ABRs that distinctly separated them from the three control groups. Specifically, wave III amplitudes were significantly lower in the AS group than for all the control groups in the forward masking condition (P < 0.005), which was not the case in the baseline condition. Thus, electrophysiological measurements of ABRs to complex sound stimuli (eg, forward masking) may lead to a better understanding of the underlying neurophysiology of AS. Future studies may further point to specific ABR characteristics in AS individuals that separate them from individuals diagnosed with other neurodevelopmental diseases. PMID:20628629

  13. Comparison of Cloud Detection Using the CERES-MODIS Ed4 and LaRC AVHRR Cloud Masks and CALIPSO Vertical Feature Mask

    NASA Astrophysics Data System (ADS)

    Trepte, Q. Z.; Minnis, P.; Palikonda, R.; Bedka, K. M.; Sun-Mack, S.

    2011-12-01

    Accurate detection of cloud amount and distribution using satellite observations is crucial in determining cloud radiative forcing and earth energy budget. The CERES-MODIS (CM) Edition 4 cloud mask is a global cloud detection algorithm for application to Terra and Aqua MODIS data with the aid of other ancillary data sets. It is used operationally for the NASA's Cloud and Earth's Radiant Energy System (CERES) project. The LaRC AVHRR cloud mask, which uses only five spectral channels, is based on a subset of the CM cloud mask which employs twelve MODIS channels. The LaRC mask is applied to AVHRR data for the NOAA Climate Data Record Program. Comparisons among the CM Ed4, and LaRC AVHRR cloud masks and the CALIPSO Vertical Feature Mask (VFM) constitute a powerful means for validating and improving cloud detection globally. They also help us understand the strengths and limitations of the various cloud retrievals which use either active and passive satellite sensors. In this paper, individual comparisons will be presented for different types of clouds over various surfaces, including daytime and nighttime, and polar and non-polar regions. Additionally, the statistics of the global, regional, and zonal cloud occurrence and amount from the CERES Ed4, AVHRR cloud masks and CALIPSO VFM will be discussed.

  14. Place specificity of monopolar and tripolar stimuli in cochlear implants: the influence of residual masking.

    PubMed

    Fielden, Claire A; Kluk, Karolina; McKay, Colette M

    2013-06-01

    This experiment investigated whether place specificity of neural activity evoked by cochlear implant stimulation is improved in tripolar compared to monopolar mode using a forward masking protocol addressing some limitations of previous methods of measurement and analysis. The amount of residual masking (masking remaining at long masker-probe delays) was also measured, and its potential influence on the specificity measures was evaluated. The masker stimulus comprised equally loud interleaved mono- or tripolar stimulation on two electrodes equidistant from a central probe electrode in an apical and basal direction, reducing the influence of off-site listening. The effect of masker-probe distance on the threshold shift of the tripolar probe was analyzed to derive a measure of place specificity. On average, tripolar maskers were more place specific than monopolar maskers, although the mean effect was small. There was no significant effect of masker level on specificity or on the differences observed between modes. The mean influence of residual masking on normalized masking functions was similar for the two modes and, therefore, did not influence the comparison of specificity between the modes. However, variability in amount of residual masking was observed between subjects, and therefore should be considered in forward masking studies that compare place specificity across subjects.

  15. Excitation-based and informational masking of a tonal signal in a four-tone masker.

    PubMed

    Leibold, Lori J; Hitchens, Jack J; Buss, Emily; Neff, Donna L

    2010-04-01

    This study examined contributions of peripheral excitation and informational masking to the variability in masking effectiveness observed across samples of multi-tonal maskers. Detection thresholds were measured for a 1000-Hz signal presented simultaneously with each of 25, four-tone masker samples. Using a two-interval, forced-choice adaptive task, thresholds were measured with each sample fixed throughout trial blocks for ten listeners. Average thresholds differed by as much as 26 dB across samples. An excitation-based model of partial loudness [Moore, B. C. J. et al. (1997). J. Audio Eng. Soc. 45, 224-237] was used to predict thresholds. These predictions accounted for a significant portion of variance in the data of several listeners, but no relation between the model and data was observed for many listeners. Moreover, substantial individual differences, on the order of 41 dB, were observed for some maskers. The largest individual differences were found for maskers predicted to produce minimal excitation-based masking. In subsequent conditions, one of five maskers was randomly presented in each interval. The difference in performance for samples with low versus high predicted thresholds was reduced in random compared to fixed conditions. These findings are consistent with a trading relation whereby informational masking is largest for conditions in which excitation-based masking is smallest.

  16. Universal Mask Usage for Reduction of Respiratory Viral Infections After Stem Cell Transplant: A Prospective Trial.

    PubMed

    Sung, Anthony D; Sung, Julia A M; Thomas, Samantha; Hyslop, Terry; Gasparetto, Cristina; Long, Gwynn; Rizzieri, David; Sullivan, Keith M; Corbet, Kelly; Broadwater, Gloria; Chao, Nelson J; Horwitz, Mitchell E

    2016-10-15

    Respiratory viral infections (RVIs) are frequent complications of hematopoietic stem cell transplant (HSCT). Surgical masks are a simple and inexpensive intervention that may reduce nosocomial spread. In this prospective single-center study, we instituted a universal surgical mask policy requiring all individuals with direct contact with HSCT patients to wear a surgical mask, regardless of symptoms or season. The primary endpoint was the incidence of RVIs in the mask period (2010-2014) compared with the premask period (2003-2009). RVIs decreased from 10.3% (95/920 patients) in the premask period to 4.4% (40/911) in the mask period (P < .001). Significant decreases occurred after both allogeneic (64/378 [16.9%] to 24/289 [8.3%], P = .001) and autologous (31/542 [5.7%] to 16/622 [2.6%], P = .007) transplants. After adjusting for multiple covariates including season and year in a segmented longitudinal analysis, the decrease in RVIs remained significant, with risk of RVI of 0.4 in patients in the mask group compared with the premask group (0.19-0.85, P = .02). In contrast, no decrease was observed during this same period in an adjacent hematologic malignancy unit, which followed the same infection control practices except for the mask policy. The majority of this decrease was in parainfluenza virus 3 (PIV3) (8.3% to 2.2%, P < .001). Requiring all individuals with direct patient contact to wear a surgical mask is associated with a reduction in RVIs, particularly PIV3, during the most vulnerable period following HSCT. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  17. Masked priming effects are modulated by expertise in the script.

    PubMed

    Perea, Manuel; Abu Mallouh, Reem; Garcı A-Orza, Javier; Carreiras, Manuel

    2011-05-01

    In a recent study using a masked priming same-different matching task, Garcı´a-Orza, Perea, and Munoz (2010) found a transposition priming effect for letter strings, digit strings, and symbol strings, but not for strings of pseudoletters (i.e., EPRI-ERPI produced similar response times to the control pair EDBI-ERPI). They argued that the mechanism responsible for position coding in masked priming is not operative with those "objects" whose identity cannot be attained rapidly. To assess this hypothesis, Experiment 1 examined masked priming effects in Arabic for native speakers of Arabic, whereas participants in Experiments 2 and 3 were lower intermediate learners of Arabic and readers with no knowledge of Arabic, respectively. Results showed a masked priming effect only for readers who are familiar with the Arabic script. Furthermore, transposed-letter priming in native speakers of Arabic only occurred when the order of the root letters was kept intact. In Experiments 3-7, we examined why masked repetition priming is absent for readers who are unfamiliar with the Arabic script. We discuss the implications of these findings for models of visual-word recognition.

  18. The impact of reverberant self-masking and overlap-masking effects on speech intelligibility by cochlear implant listeners (L).

    PubMed

    Kokkinakis, Kostas; Loizou, Philipos C

    2011-09-01

    The purpose of this study is to determine the relative impact of reverberant self-masking and overlap-masking effects on speech intelligibility by cochlear implant listeners. Sentences were presented in two conditions wherein reverberant consonant segments were replaced with clean consonants, and in another condition wherein reverberant vowel segments were replaced with clean vowels. The underlying assumption is that self-masking effects would dominate in the first condition, whereas overlap-masking effects would dominate in the second condition. Results indicated that the degradation of speech intelligibility in reverberant conditions is caused primarily by self-masking effects that give rise to flattened formant transitions. © 2011 Acoustical Society of America

  19. An ultrasound evaluation of laryngeal mask airway position in pediatric patients: an observational study.

    PubMed

    Kim, Jeongmin; Kim, Ji Young; Kim, Won Oak; Kil, Hae Keum

    2015-02-01

    In children, the laryngeal mask airway (LMA) is frequently displaced within the hypopharynx, resulting in repositioning of the device. When the tip of the LMA is placed in the esophageal inlet, the arytenoids are moved ventrally. When the LMA is rotated or deviated, the ventral movement of the arytenoids may result in asymmetric elevation of an arytenoid cartilage, which can be detected with ultrasound (US). In this study, we sought to estimate the incidence of LMA malposition detected with US in pediatric patients. The primary end point was to compare the incidence of LMA malposition between US and fiber optic bronchoscopy (FOB). The secondary end points were to find the interrelationship between US-detected and FOB-detected malposition of the LMA and to locate the diagnostic performance of US in detecting LMA malposition. In this observational study, 100 consecutive children were included. After anesthetic induction, US evaluation was performed before and after LMA insertion to obtain the glottic image on the anterior neck. FOB was performed to assess LMA position (FOB LMA grade and LMA rotation grade). With a post-LMA US image, the symmetry of the arytenoid cartilages was evaluated. Asymmetrical elevation of an arytenoid cartilage in reference to the glottic midline and the opposite arytenoid cartilage was graded as 0 to 3 (US arytenoid grade). The interrelationships between US arytenoid grade and FOB LMA grade or LMA rotation grade were assessed. The incidence of asymmetrical elevation of an arytenoid was 50% (95% confidence interval [CI], 40%-60%). On FOB, the incidence of LMA malposition was 78% (95% CI, 69%-86%), and that of LMA rotation was 43% (95% CI, 33%-53%). The incidence of LMA malposition was higher with FOB (P < 0.0001), but the incidence of rotation was similar (P = 0.395). US arytenoid grade did not correlate with FOB LMA grade (P = 0.611) but showed a significant correlation with LMA rotation grade (P < 0.0001; 95% CI, 60%-83%). To detect a

  20. Extension of optical lithography by mask-litho integration with computational lithography

    NASA Astrophysics Data System (ADS)

    Takigawa, T.; Gronlund, K.; Wiley, J.

    2010-05-01

    Wafer lithography process windows can be enlarged by using source mask co-optimization (SMO). Recently, SMO including freeform wafer scanner illumination sources has been developed. Freeform sources are generated by a programmable illumination system using a micro-mirror array or by custom Diffractive Optical Elements (DOE). The combination of freeform sources and complex masks generated by SMO show increased wafer lithography process window and reduced MEEF. Full-chip mask optimization using source optimized by SMO can generate complex masks with small variable feature size sub-resolution assist features (SRAF). These complex masks create challenges for accurate mask pattern writing and low false-defect inspection. The accuracy of the small variable-sized mask SRAF patterns is degraded by short range mask process proximity effects. To address the accuracy needed for these complex masks, we developed a highly accurate mask process correction (MPC) capability. It is also difficult to achieve low false-defect inspections of complex masks with conventional mask defect inspection systems. A printability check system, Mask Lithography Manufacturability Check (M-LMC), is developed and integrated with 199-nm high NA inspection system, NPI. M-LMC successfully identifies printable defects from all of the masses of raw defect images collected during the inspection of a complex mask. Long range mask CD uniformity errors are compensated by scanner dose control. A mask CD uniformity error map obtained by mask metrology system is used as input data to the scanner. Using this method, wafer CD uniformity is improved. As reviewed above, mask-litho integration technology with computational lithography is becoming increasingly important.

  1. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

    PubMed

    Tracy, Mark Brian; Priyadarshi, Archana; Goel, Dimple; Lowe, Krista; Huvanandana, Jacqueline; Hinder, Murray

    2018-05-01

    International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH 2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH 2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH 2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. What Is Being Masked in Object Substitution Masking?

    ERIC Educational Resources Information Center

    Gellatly, Angus; Pilling, Michael; Cole, Geoff; Skarratt, Paul

    2006-01-01

    Object substitution masking (OSM) is said to occur when a perceptual object is hypothesized that is mismatched by subsequent sensory evidence, leading to a new hypothesized object being substituted for the first. For example, when a brief target is accompanied by a longer lasting display of nonoverlapping mask elements, reporting of target…

  3. Schizophrenia alters intra-network functional connectivity in the caudate for detecting speech under informational speech masking conditions.

    PubMed

    Zheng, Yingjun; Wu, Chao; Li, Juanhua; Li, Ruikeng; Peng, Hongjun; She, Shenglin; Ning, Yuping; Li, Liang

    2018-04-04

    Speech recognition under noisy "cocktail-party" environments involves multiple perceptual/cognitive processes, including target detection, selective attention, irrelevant signal inhibition, sensory/working memory, and speech production. Compared to health listeners, people with schizophrenia are more vulnerable to masking stimuli and perform worse in speech recognition under speech-on-speech masking conditions. Although the schizophrenia-related speech-recognition impairment under "cocktail-party" conditions is associated with deficits of various perceptual/cognitive processes, it is crucial to know whether the brain substrates critically underlying speech detection against informational speech masking are impaired in people with schizophrenia. Using functional magnetic resonance imaging (fMRI), this study investigated differences between people with schizophrenia (n = 19, mean age = 33 ± 10 years) and their matched healthy controls (n = 15, mean age = 30 ± 9 years) in intra-network functional connectivity (FC) specifically associated with target-speech detection under speech-on-speech-masking conditions. The target-speech detection performance under the speech-on-speech-masking condition in participants with schizophrenia was significantly worse than that in matched healthy participants (healthy controls). Moreover, in healthy controls, but not participants with schizophrenia, the strength of intra-network FC within the bilateral caudate was positively correlated with the speech-detection performance under the speech-masking conditions. Compared to controls, patients showed altered spatial activity pattern and decreased intra-network FC in the caudate. In people with schizophrenia, the declined speech-detection performance under speech-on-speech masking conditions is associated with reduced intra-caudate functional connectivity, which normally contributes to detecting target speech against speech masking via its functions of suppressing masking-speech signals.

  4. Different effects of the two types of spatial pre-cueing: what precisely is "attention" in Di Lollo's and Enns' substitution masking theory?

    PubMed

    Luiga, I; Bachmann, T

    2007-11-01

    Enns and Di Lollo [Psychological Science, 8 (2), 135-139, 1997] have introduced the object substitution theory of visual masking. Object substitution masking occurs when focusing attention on the target is delayed. However, Posner (Quarterly Journal of Experimental Psychology, 32, 3-25, 1980) has already shown that attention can be directed to a target at least in two ways: intentionally (endogenously) and automatically (exogenously). We conducted two experiments to explore the effects of endogenous and exogenous cues on substitution masking. The results showed that when attention was shifted to the target location automatically (using a local peripheral pre-cue), masking was attenuated. A decrease in target identification dependent on a delay of mask offset, typical to substitution masking, was not observed. However, strong substitution masking occurred when the target location was not pre-cued or when attention was directed to the target location intentionally (using a symbolic pre-cue displayed centrally). The hypothesis of two different mechanisms of attentional control in substitution masking was confirmed.

  5. Short-term visual deprivation can enhance spatial release from masking.

    PubMed

    Pagé, Sara; Sharp, Andréanne; Landry, Simon P; Champoux, François

    2016-08-15

    This research aims to study the effect of short-term visual deprivation on spatial release from masking, a major component of the cocktail party effect that allows people to detect an auditory target in noise. The Masking Level Difference (MLD) test was administered on healthy individuals over three sessions: before (I) and after 90min of visual deprivation (II), and after 90min of re-exposure to light (III). A non-deprived control group performed the same tests, but remained sighted between sessions I and II. The non-deprived control group displayed constant results across sessions. However, performance in the MLD test was improved following short-term visual deprivation and performance returned to pre-deprivation values after light re-exposure. This study finds that short-term visual deprivation transiently enhances the spatial release from masking. These data suggest the significant potential for enhancing a process involved in the cocktail party effect in normally developing individuals and adds to an emerging literature on the potential to enhance auditory ability after only a brief period of visual deprivation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Brightness masking is modulated by disparity structure.

    PubMed

    Pelekanos, Vassilis; Ban, Hiroshi; Welchman, Andrew E

    2015-05-01

    The luminance contrast at the borders of a surface strongly influences surface's apparent brightness, as demonstrated by a number of classic visual illusions. Such phenomena are compatible with a propagation mechanism believed to spread contrast information from borders to the interior. This process is disrupted by masking, where the perceived brightness of a target is reduced by the brief presentation of a mask (Paradiso & Nakayama, 1991), but the exact visual stage that this happens remains unclear. In the present study, we examined whether brightness masking occurs at a monocular-, or a binocular-level of the visual hierarchy. We used backward masking, whereby a briefly presented target stimulus is disrupted by a mask coming soon afterwards, to show that brightness masking is affected by binocular stages of the visual processing. We manipulated the 3-D configurations (slant direction) of the target and mask and measured the differential disruption that masking causes on brightness estimation. We found that the masking effect was weaker when stimuli had a different slant. We suggest that brightness masking is partly mediated by mid-level neuronal mechanisms, at a stage where binocular disparity edge structure has been extracted. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Combining Simultaneous with Temporal Masking

    ERIC Educational Resources Information Center

    Hermens, Frouke; Herzog, Michael H.; Francis, Gregory

    2009-01-01

    Simultaneous and temporal masking are two frequently used techniques in psychology and vision science. Although there are many studies and theories related to each masking technique, there are no systematic investigations of their mutual relationship, even though both techniques are often applied together. Here, the authors show that temporal…

  8. Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    NASA Technical Reports Server (NTRS)

    Newman, Kevin Edward; Belikov, Ruslan; Guyon, Olivier; Balasubramanian, Kunjithapatham; Wilson, Dan

    2013-01-01

    Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

  9. Oral mask ventilation is more effective than face mask ventilation after nasal surgery.

    PubMed

    Yazicioğlu, Dilek; Baran, Ilkay; Uzumcugil, Filiz; Ozturk, Ibrahim; Utebey, Gulten; Sayın, M Murat

    2016-06-01

    To evaluate and compare the face mask (FM) and oral mask (OM) ventilation techniques during anesthesia emergence regarding tidal volume, leak volume, and difficult mask ventilation (DMV) incidence. Prospective, randomized, crossover study. Operating room, training and research hospital. American Society of Anesthesiologists physical status I and II adult patients scheduled for nasal surgery. Patients in group FM-OM received FM ventilation first, followed by OM ventilation, and patients in group OM-FM received OM ventilation first, followed by FM ventilation, with spontaneous ventilation after deep extubation. The FM ventilation was applied with the 1-handed EC-clamp technique. The OM was placed only over the mouth, and the 1-handed EC-clamp technique was used again. A child's size FM was used for the OM ventilation technique, the mask was rotated, and the inferior part of the mask was placed toward the nose. The leak volume (MVleak), mean airway pressure (Pmean), and expired tidal volume (TVe) were assessed with each mask technique for 3 consecutive breaths. A mask ventilation grade ≥3 was considered DMV. DMV occurred more frequently during FM ventilation (75% with FM vs 8% with OM). In the FM-first sequence, the mean TVe was 249±61mL with the FM and 455±35mL with the OM (P=.0001), whereas in the OM-first sequence, it was 276±81mL with the FM and 409±37mL with the OM (P=.0001). Regardless of the order used, the OM technique significantly decreased the MVleak and increased the TVe when compared to the FM technique. During anesthesia emergence after nasal surgery the OM may offer an effective ventilation method as it decreases the incidence of DMV and the gas leak around the mask and provides higher tidal volume delivery compared with FM ventilation. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Progress on EUV mask fabrication for 32-nm technology node and beyond

    NASA Astrophysics Data System (ADS)

    Zhang, Guojing; Yan, Pei-Yang; Liang, Ted; Park, Seh-jin; Sanchez, Peter; Shu, Emily Y.; Ultanir, Erdem A.; Henrichs, Sven; Stivers, Alan; Vandentop, Gilroy; Lieberman, Barry; Qu, Ping

    2007-05-01

    Extreme ultraviolet lithography (EUVL) tool development achieved a big milestone last year as two full-field Alpha Demo Tools (ADT) were shipped to customers by ASML. In the future horizon, a full field "EUV1" exposure tool from Nikon will be available by the end of 20071 and the pre-production EUV exposure tools from ASML are targeted for 20092. It is essential that high quality EUVL masks can be made and delivered to the EUVL tool users to support the technology development. In the past year, we have demonstrated mask fabrication with low stress absorber deposition and good etch process control yielding a vertical etch profile and a mask CD control of 5.7 nm for 32 nm (1x) space and 7.4 nm for 32 nm (1x) lines. Mask pattern resolution of 15 nm (1x) dense lines was achieved. Full field reflective mask die-to-die inspection at a 125nm pixel size was demonstrated after low defect multilayer blanks became available. In this paper, we will present details of the Intel EUVL Mask Pilot Line progress in EUVL mask defect reduction, pattern CD performance, program defect mask design and inspection, in-house absorber film development and its performance, and EUVL metrology tool development. We will demonstrate an overall improvement in EUV mask manufacturing readiness due to our Pilot Line activities.

  11. Masking in three pinnipeds: underwater, low-frequency critical ratios.

    PubMed

    Southall, B L; Schusterman, R J; Kastak, D

    2000-09-01

    Behavioral techniques were used to determine underwater masked hearing thresholds for a northern elephant seal (Mirounga angustirostris), a harbor seal (Phoca vitulina), and a California sea lion (Zalophus californianus). Octave-band white noise maskers were centered at five test frequencies ranging from 200 to 2500 Hz; a slightly wider noise band was used for testing at 100 Hz. Critical ratios were calculated at one masking noise level for each test frequency. Above 200 Hz, critical ratios increased with frequency. This pattern is similar to that observed in most animals tested, and indicates that these pinnipeds lack specializations for detecting low-frequency tonal sounds in noise. However, the individual pinnipeds in this study, particularly the northern elephant seal, detected signals at relatively low signal-to-noise ratios. These results provide a means of estimating zones of auditory masking for pinnipeds exposed to anthropogenic noise sources.

  12. Automatic pattern localization across layout database and photolithography mask

    NASA Astrophysics Data System (ADS)

    Morey, Philippe; Brault, Frederic; Beisser, Eric; Ache, Oliver; Röth, Klaus-Dieter

    2016-03-01

    Advanced process photolithography masks require more and more controls for registration versus design and critical dimension uniformity (CDU). The distribution of the measurement points should be distributed all over the whole mask and may be denser in areas critical to wafer overlay requirements. This means that some, if not many, of theses controls should be made inside the customer die and may use non-dedicated patterns. It is then mandatory to access the original layout database to select patterns for the metrology process. Finding hundreds of relevant patterns in a database containing billions of polygons may be possible, but in addition, it is mandatory to create the complete metrology job fast and reliable. Combining, on one hand, a software expertise in mask databases processing and, on the other hand, advanced skills in control and registration equipment, we have developed a Mask Dataprep Station able to select an appropriate number of measurement targets and their positions in a huge database and automatically create measurement jobs on the corresponding area on the mask for the registration metrology system. In addition, the required design clips are generated from the database in order to perform the rendering procedure on the metrology system. This new methodology has been validated on real production line for the most advanced process. This paper presents the main challenges that we have faced, as well as some results on the global performances.

  13. The Effect Of Digital Unsharp Masking On The Detectability Of Interstitial Infiltrates And Pneumothoraces

    NASA Astrophysics Data System (ADS)

    MacMahon, Heber; Vyborny, Carl; Sabeti, Victoria; Metz, Charles; Doi, Kunio

    1985-09-01

    A potential advantage of digital radiographic systems is their ability to enhance images by various types of processing. Digital unsharp masking is one of the simplest and potentially most useful forms of enhancement. The efficacy of unsharp masking in clinical radiologic diagnosis has not been investigated systematically, however. The effect of digital unsharp masking on the detectability of two types of subtle abnormalities, pneumothorax and interstitial infiltrate, was studied in an observer performance test. An ROC analysis of this preliminary data suggests that unsharp masking may improve diagnostic accuracy for pneumothorax. Radiologists' performance in identifying interstitial infiltrates was degraded by the image processing, however, and false positive diagnoses tended to be more frequent.

  14. Hot melt extrusion of ion-exchange resin for taste masking.

    PubMed

    Tan, David Cheng Thiam; Ong, Jeremy Jianming; Gokhale, Rajeev; Heng, Paul Wan Sia

    2018-05-30

    Taste masking is important for some unpleasant tasting bioactives in oral dosage forms. Among many methods available for taste-masking, use of ion-exchange resin (IER) holds promise. IER combined with hot melt extrusion (HME) may offer additional advantages over solvent methods. IER provides taste masking by complexing with the drug ions and preventing drug dissolution in the mouth. Drug-IER complexation approaches described in literatures are mainly based either on batch processing or column eluting. These methods of drug-IER complexation have obvious limitations such as high solvent volume requirements, multiprocessing steps and extended processing time. Thus, the objective of this study was to develop a single-step, solvent-free, continuous HME process for complexation of drug-IER. The screening study evaluated drug to IER ratio, types of IER and drug complexation methods. In the screening study, a potassium salt of a weakly acidic carboxylate-based cationic IER was found suitable for the HME method. Thereafter, optimization study was conducted by varying HME process parameters such as screw speed, extrusion temperature and drug to IER ratio. It was observed that extrusion temperature and drug to IER ratio are imperative in drug-IER complexation through HME. In summary, this study has established the feasibility of a continuous complexation method for drug to IER using HME for taste masking. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Ipsilateral masking between acoustic and electric stimulations.

    PubMed

    Lin, Payton; Turner, Christopher W; Gantz, Bruce J; Djalilian, Hamid R; Zeng, Fan-Gang

    2011-08-01

    Residual acoustic hearing can be preserved in the same ear following cochlear implantation with minimally traumatic surgical techniques and short-electrode arrays. The combined electric-acoustic stimulation significantly improves cochlear implant performance, particularly speech recognition in noise. The present study measures simultaneous masking by electric pulses on acoustic pure tones, or vice versa, to investigate electric-acoustic interactions and their underlying psychophysical mechanisms. Six subjects, with acoustic hearing preserved at low frequencies in their implanted ear, participated in the study. One subject had a fully inserted 24 mm Nucleus Freedom array and five subjects had Iowa/Nucleus hybrid implants that were only 10 mm in length. Electric masking data of the long-electrode subject showed that stimulation from the most apical electrodes produced threshold elevations over 10 dB for 500, 625, and 750 Hz probe tones, but no elevation for 125 and 250 Hz tones. On the contrary, electric stimulation did not produce any electric masking in the short-electrode subjects. In the acoustic masking experiment, 125-750 Hz pure tones were used to acoustically mask electric stimulation. The acoustic masking results showed that, independent of pure tone frequency, both long- and short-electrode subjects showed threshold elevations at apical and basal electrodes. The present results can be interpreted in terms of underlying physiological mechanisms related to either place-dependent peripheral masking or place-independent central masking.

  16. The EOS CERES Global Cloud Mask

    NASA Technical Reports Server (NTRS)

    Berendes, T. A.; Welch, R. M.; Trepte, Q.; Schaaf, C.; Baum, B. A.

    1996-01-01

    To detect long-term climate trends, it is essential to produce long-term and consistent data sets from a variety of different satellite platforms. With current global cloud climatology data sets, such as the International Satellite Cloud Climatology Experiment (ISCCP) or CLAVR (Clouds from Advanced Very High Resolution Radiometer), one of the first processing steps is to determine whether an imager pixel is obstructed between the satellite and the surface, i.e., determine a cloud 'mask.' A cloud mask is essential to studies monitoring changes over ocean, land, or snow-covered surfaces. As part of the Earth Observing System (EOS) program, a series of platforms will be flown beginning in 1997 with the Tropical Rainfall Measurement Mission (TRMM) and subsequently the EOS-AM and EOS-PM platforms in following years. The cloud imager on TRMM is the Visible/Infrared Sensor (VIRS), while the Moderate Resolution Imaging Spectroradiometer (MODIS) is the imager on the EOS platforms. To be useful for long term studies, a cloud masking algorithm should produce consistent results between existing (AVHRR) data, and future VIRS and MODIS data. The present work outlines both existing and proposed approaches to detecting cloud using multispectral narrowband radiance data. Clouds generally are characterized by higher albedos and lower temperatures than the underlying surface. However, there are numerous conditions when this characterization is inappropriate, most notably over snow and ice of the cloud types, cirrus, stratocumulus and cumulus are the most difficult to detect. Other problems arise when analyzing data from sun-glint areas over oceans or lakes over deserts or over regions containing numerous fires and smoke. The cloud mask effort builds upon operational experience of several groups that will now be discussed.

  17. Effectiveness of surgical masks against influenza bioaerosols.

    PubMed

    Makison Booth, C; Clayton, M; Crook, B; Gawn, J M

    2013-05-01

    Most surgical masks are not certified for use as respiratory protective devices (RPDs). In the event of an influenza pandemic, logistical and practical implications such as storage and fit testing will restrict the use of RPDs to certain high-risk procedures that are likely to generate large amounts of infectious bioaerosols. Studies have shown that in such circumstances increased numbers of surgical masks are worn, but the protection afforded to the wearer by a surgical mask against infectious aerosols is not well understood. To develop and apply a method for assessing the protection afforded by surgical masks against a bioaerosol challenge. A dummy test head attached to a breathing simulator was used to test the performance of surgical masks against a viral challenge. Several designs of surgical masks commonly used in the UK healthcare sector were evaluated by measuring levels of inert particles and live aerosolised influenza virus in the air, from in front of and behind each mask. Live influenza virus was measurable from the air behind all surgical masks tested. The data indicate that a surgical mask will reduce exposure to aerosolised infectious influenza virus; reductions ranged from 1.1- to 55-fold (average 6-fold), depending on the design of the mask. We describe a workable method to evaluate the protective efficacy of surgical masks and RPDs against a relevant aerosolised biological challenge. The results demonstrated limitations of surgical masks in this context, although they are to some extent protective. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  18. Perceptual learning for speech in noise after application of binary time-frequency masks

    PubMed Central

    Ahmadi, Mahnaz; Gross, Vauna L.; Sinex, Donal G.

    2013-01-01

    Ideal time-frequency (TF) masks can reject noise and improve the recognition of speech-noise mixtures. An ideal TF mask is constructed with prior knowledge of the target speech signal. The intelligibility of a processed speech-noise mixture depends upon the threshold criterion used to define the TF mask. The study reported here assessed the effect of training on the recognition of speech in noise after processing by ideal TF masks that did not restore perfect speech intelligibility. Two groups of listeners with normal hearing listened to speech-noise mixtures processed by TF masks calculated with different threshold criteria. For each group, a threshold criterion that initially produced word recognition scores between 0.56–0.69 was chosen for training. Listeners practiced with one set of TF-masked sentences until their word recognition performance approached asymptote. Perceptual learning was quantified by comparing word-recognition scores in the first and last training sessions. Word recognition scores improved with practice for all listeners with the greatest improvement observed for the same materials used in training. PMID:23464038

  19. Etch bias inversion during EUV mask ARC etch

    NASA Astrophysics Data System (ADS)

    Lajn, Alexander; Rolff, Haiko; Wistrom, Richard

    2017-07-01

    The introduction of EUV lithography to high volume manufacturing is now within reach for 7nm technology node and beyond (1), at least for some steps. The scheduling is in transition from long to mid-term. Thus, all contributors need to focus their efforts on the production requirements. For the photo mask industry, these requirements include the control of defectivity, CD performance and lifetime of their masks. The mask CD performance including CD uniformity, CD targeting, and CD linearity/ resolution, is predominantly determined by the photo resist performance and by the litho and etch processes. State-of-the-art chemically amplified resists exhibit an asymmetric resolution for directly and indirectly written features, which usually results in a similarly asymmetric resolution performance on the mask. This resolution gap may reach as high as multiple tens of nanometers on the mask level in dependence of the chosen processes. Depending on the printing requirements of the wafer process, a reduction or even an increase of this gap may be required. A potential way of tuning via the etch process, is to control the lateral CD contribution during etch. Aside from process tuning knobs like pressure, RF powers and gases, which usually also affect CD linearity and CD uniformity, the simplest knob is the etch time itself. An increased over etch time results in an increased CD contribution in the normal case. , We found that the etch CD contribution of ARC layer etch on EUV photo masks is reduced by longer over etch times. Moreover, this effect can be demonstrated to be present for different etch chambers and photo resists.

  20. Fabless company mask technology approach: fabless but not fab-careless

    NASA Astrophysics Data System (ADS)

    Hisamura, Toshiyuki; Wu, Xin

    2009-10-01

    There are two different foundry-fabless working models in the aspect of mask. Some foundries have in-house mask facility while others contract with merchant mask vendors. Significant progress has been made in both kinds of situations. Xilinx as one of the pioneers of fabless semiconductor companies has been continually working very closely with both merchant mask vendors and mask facilities of foundries in past many years, contributed well in both technology development and benefited from corporations. Our involvement in manufacturing is driven by the following three elements: The first element is to understand the new fabrication and mask technologies and then find a suitable design / layout style to better utilize these new technologies and avoid potential risks. Because Xilinx has always been involved in early stage of advanced technology nodes, this early understanding and adoption is especially important. The second element is time to market. Reduction in mask and wafer manufacturing cycle-time can ensure faster time to market. The third element is quality. Commitment to quality is our highest priority for our customers. We have enough visibility on any manufacturing issues affecting the device functionality. Good correlation has consistently been observed between FPGA speed uniformity and the poly mask Critical Dimension (CD) uniformity performance. To achieve FPGA speed uniformity requirement, the manufacturing process as well as the mask and wafer CD uniformity has to be monitored. Xilinx works closely with the wafer foundries and mask suppliers to improve productivity and the yield from initial development stage of mask making operations. As an example, defect density reduction is one of the biggest challenges for mask supplier in development stage to meet the yield target satisfying the mask cost and mask turn-around-time (TAT) requirement. Historically, masks were considered to be defect free but at these advanced process nodes, that assumption no longer

  1. Optimal mask characterization by Surrogate Wafer Print (SWaP) method

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hoellein, Ingo; Peters, Jan Hendrick; Ackmann, Paul; Connolly, Brid; West, Craig

    2008-10-01

    enhancement to mask characterization quality including defectivity, dimensional control, pattern fidelity, and in-plane distortion. We present a thorough analysis of both the technical and logistical challenges coupled with an objective view of the advantages and disadvantages from both the technical and financial perspectives. The analysis and model used by the AMTC will serve to provoke other mask shops to prepare their own analyses then consider this new paradigm for mask characterization and qualification.

  2. Variations in backward masking with different masking stimuli: II. The effects of spatially quantised masks in the light of local contour interaction, interchannel inhibition, perceptual retouch, and substitution theories.

    PubMed

    Bachmann, Talis; Luiga, Iiris; Põder, Endel

    2005-01-01

    In part I we showed that with spatially non-overlapping targets and masks both local metacontrast-like interactions and attentional processes are involved in backward masking. In this second part we extend the strategy of varying the contents of masks to pattern masking where targets and masks overlap in space, in order to compare different masking theories. Images of human faces were backward-masked by three types of spatially quantised masks (the same faces as targets, faces different from targets, and Gaussian noise with power spectra typical for faces). Configural characteristics, rather than the spectral content of the mask, predicted the extent of masking at relatively long stimulus onset asynchronies (SOAs). This poses difficulties for the theory of transient-on-sustained inhibition as the principal mechanism of masking and also for local contour interaction being a decisive factor in pattern masking. The scale of quantisation had no effect on the masking capacity of noise masks and a strong effect on the capacity of different-face masks. Also, the decrease of configural masking with an increase in the coarseness of the quantisation of the mask highlights ambiguities inherent in the re-entrance-based substitution theory of masking. Different masking theories cannot solve the problems of masking separately. They should be combined in order to create a complex, yet comprehensible mode of interaction for the different mechanisms involved in visual backward masking.

  3. Modulation cues influence binaural masking-level difference in masking-pattern experiments.

    PubMed

    Nitschmann, Marc; Verhey, Jesko L

    2012-03-01

    Binaural masking patterns show a steep decrease in the binaural masking-level difference (BMLD) when masker and signal have no frequency component in common. Experimental threshold data are presented together with model simulations for a diotic masker centered at 250 or 500 Hz and a bandwidth of 10 or 100 Hz masking a sinusoid interaurally in phase (S(0)) or in antiphase (S(π)). Simulations with a binaural model, including a modulation filterbank for the monaural analysis, indicate that a large portion of the decrease in the BMLD in remote-masking conditions may be due to an additional modulation cue available for monaural detection. © 2012 Acoustical Society of America

  4. Mask industry assessment: 2008

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Yun, Henry

    2008-10-01

    Microelectronics industry leaders routinely name the cost and cycle time of mask technology and mask supply as top critical issues. A survey was created with support from SEMATECH and administered by David Powell Consulting to gather information about the mask industry as an objective assessment of its overall condition. The survey is designed with the input of semiconductor company mask technologists, merchant mask suppliers, and industry equipment makers. This year's assessment is the seventh in the current series of annual reports. With ongoing industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. The results will be used to guide future investments pertaining to critical path issues. This year's survey is basically the same as the 2005 through 2007 surveys. Questions are grouped into categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category is a multitude of questions that create a detailed profile of both the business and technical status of the critical mask industry.

  5. Mask industry assessment: 2009

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Yun, Henry

    2009-10-01

    Microelectronics industry leaders routinely name the cost and cycle time of mask technology and mask supply as top critical issues. A survey was created with support from SEMATECH and administered by David Powell Consulting to gather information about the mask industry as an objective assessment of its overall condition. The survey is designed with the input of semiconductor company mask technologists and merchant mask suppliers. This year's assessment is the eighth in the current series of annual reports. With ongoing industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. The results will be used to guide future investments pertaining to critical path issues. This year's survey is basically the same as the 2005 through 2008 surveys. Questions are grouped into categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category is a multitude of questions that create a detailed profile of both the business and technical status of the critical mask industry. This in combination with the past surveys represents a comprehensive view of changes in the industry.

  6. Masked Repetition Priming Using Magnetoencephalography

    ERIC Educational Resources Information Center

    Monahan, Philip J.; Fiorentino, Robert; Poeppel, David

    2008-01-01

    Masked priming is used in psycholinguistic studies to assess questions about lexical access and representation. We present two masked priming experiments using MEG. If the MEG signal elicited by words reflects specific aspects of lexical retrieval, then one expects to identify specific neural correlates of retrieval that are sensitive to priming.…

  7. The pilus usher controls protein interactions via domain masking and is functional as an oligomer.

    PubMed

    Werneburg, Glenn T; Henderson, Nadine S; Portnoy, Erica B; Sarowar, Samema; Hultgren, Scott J; Li, Huilin; Thanassi, David G

    2015-07-01

    The chaperone-usher (CU) pathway assembles organelles termed pili or fimbriae in Gram-negative bacteria. Type 1 pili expressed by uropathogenic Escherichia coli are prototypical structures assembled by the CU pathway. Biogenesis of pili by the CU pathway requires a periplasmic chaperone and an outer-membrane protein termed the usher (FimD). We show that the FimD C-terminal domains provide the high-affinity substrate-binding site but that these domains are masked in the resting usher. Domain masking requires the FimD plug domain, which serves as a switch controlling usher activation. We demonstrate that usher molecules can act in trans for pilus biogenesis, providing conclusive evidence for a functional usher oligomer. These results reveal mechanisms by which molecular machines such as the usher regulate and harness protein-protein interactions and suggest that ushers may interact in a cooperative manner during pilus assembly in bacteria.

  8. The Pilus Usher Controls Protein Interactions via Domain Masking and is Functional as an Oligomer

    PubMed Central

    Werneburg, Glenn T.; Henderson, Nadine S.; Portnoy, Erica B.; Sarowar, Samema; Hultgren, Scott J.; Li, Huilin; Thanassi, David G.

    2015-01-01

    The chaperone-usher (CU) pathway assembles organelles termed pili or fimbriae in Gram-negative bacteria. Type 1 pili expressed by uropathogenic Escherichia coli are prototypical structures assembled by the CU pathway. Biogenesis of pili by the CU pathway requires a periplasmic chaperone and an outer membrane protein termed the usher (FimD). We show that the FimD C-terminal domains provide the high-affinity substrate binding site, but that these domains are masked in the resting usher. Domain masking requires the FimD plug domain, which serves as a switch controlling usher activation. We demonstrate that usher molecules can act in trans for pilus biogenesis, providing conclusive evidence for a functional usher oligomer. These results reveal mechanisms by which molecular machines such as the usher regulate and harness protein-protein interactions, and suggest that ushers may interact in a cooperative manner during pilus assembly in bacteria. PMID:26052892

  9. X ray reflection masks: Manufacturing, characterization and first tests

    NASA Astrophysics Data System (ADS)

    Rahn, Stephen

    1992-09-01

    SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  10. Evaluation Of Digital Unsharp-Mask Filtering For The Detection Of Subtle Mammographic Microcalcifications

    NASA Astrophysics Data System (ADS)

    Chan, Heang-Ping; Vyborny, Carl J.; MacMahon, Heber; Metz, Charles E.; Doi, Kunio; Sickles, Edward A.

    1986-06-01

    We have conducted a study to assess the effects of digitization and unsharp-mask filtering on the ability of observers to detect subtle microcalcifications in mammograms. Thirty-two conventional screen-film mammograms were selected from patient files by two experienced mammographers. Twelve of the mammograms contained a suspicious cluster of microcalcifications in patients who subsequently underwent biopsy. Twenty of the mammograms were normal cases which were initially interpreted as being free of clustered microcalcifications and did not demonstrate such on careful review. The mammograms were digitized with a high-quality Fuji image processing/simulation system. The system consists of two drum scanners with which an original radiograph can be digitized, processed by a minicomputer, and reconstituted on film. In this study, we employed a sampling aperture of 0.1 mm X 0.1 mm and a sampling distance of 0.1 mm. The density range from 0.2 to 2.75 was digitized to 1024 grey levels per pixel. The digitized images were printed on a single emulsion film with a display aperture having the same size as the sampling aperture. The system was carefully calibrated so that the density and contrast of a digitized image were closely matched to those of the original radiograph. Initially, we evaluated the effects of the weighting factor and the mask size of a unsharp-mask filter on the appearance of mammograms for various types of breasts. Subjective visual comparisons suggested that a mask size of 91 X 91 pixels (9.1 mm X 9.1 mm) enhances the visibility of microcalcifications without excessively increasing the high-frequency noise. Further, a density-dependent weighting factor that increases linearly from 1.5 to 3.0 in the density range of 0.2 to 2.5 enhances the contrast of microcalcifications without introducing many potentially confusing artifacts in the low-density areas. An unsharp-mask filter with these parameters was used to process the digitized mammograms. We conducted

  11. Tinnitus retraining therapy: mixing point and total masking are equally effective.

    PubMed

    Tyler, Richard S; Noble, William; Coelho, Claudia Barros; Ji, Haihong

    2012-01-01

    Habituation to tinnitus cannot occur with total masking, an argument made by proponents of "tinnitus retraining therapy." We also compared the effectiveness of retraining therapy with mixing-point masking, total masking, and with counseling alone. Forty-eight tinnitus patients were randomly assigned to one of three groups: counseling, counseling plus bilateral noise generators set to completely mask the tinnitus, or counseling plus bilateral noise generators with a focus on the mixing point (partial masking just below total masking). A picture-based counseling protocol was used to assist in providing similar counseling among all three groups. The Tinnitus Handicap Questionnaire was administered before and after about 12 months of treatment. After 12 months, in the counseling group, three of 18 patients benefited significantly, in the mixing-point group, six of 19 patients benefited, and in the total masking group, four of 11 patients benefited from the treatment. The average decrease in the questionnaire was 16.7% for the counseling group, 31.6% for the retraining group, and 36.4% for the total masking group. No significant average differences among groups were observed. One premise of retraining therapy is incorrect; a focus on mixing-point masking is not required for habituation.

  12. Use of adjunctive mitomycin C in external dacryocystorhinostomy surgery compared with surgery alone in patients with nasolacrimal duct obstruction: A prospective, double-masked, randomized, controlled trial.

    PubMed

    Ari, Seyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Caca, Ihsan

    2009-08-01

    on nasolacrimal duct irrigation, significantly fewer patients in the MMC group than the control group had an enclosed naso-lacrimal duct (2/50 [4%] vs 8/50 [16%]). No adverse effects (eg, abnormal nasal bleeding, mucosal necrosis, infection) or any other surgical adverse events were observed. In the management of these patients with primary acquired nasolacrimal duct obstruction, adjunctive intraoperative MMC application with standard DCR surgery had a significantly higher success rate than did standard DCR surgery alone. Further large, double-masked, randomized studies are needed to confirm these findings.

  13. Use of adjunctive mitomycin C in external dacryocystorhinostomy surgery compared with surgery alone in patients with nasolacrimal duct obstruction: A prospective, double-masked, randomized, controlled trial

    PubMed Central

    Ari, Şeyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Çaca, Îhsan

    2009-01-01

    (48/50 [96%] vs 42/50 [84%]; P=0.005). Based on nasolacrimal duct irrigation, significantly fewer patients in the MMC group than the control group had an enclosed naso-lacrimal duct (2/50 [4%] vs 8/50 [16%]). No adverse effects (eg, abnormal nasal bleeding, mucosal necrosis, infection) or any other surgical adverse events were observed. Conclusions: In the management of these patients with primary acquired nasolacrimal duct obstruction, adjunctive intraoperative MMC application with standard DCR surgery had a significantly higher success rate than did standard DCR surgery alone. Further large, double-masked, randomized studies are needed to confirm these findings. PMID:24683236

  14. EUV phase-shifting masks and aberration monitors

    NASA Astrophysics Data System (ADS)

    Deng, Yunfei; Neureuther, Andrew R.

    2002-07-01

    Rigorous electromagnetic simulation with TEMPEST is used to examine the use of phase-shifting masks in EUV lithography. The effects of oblique incident illumination and mask patterning by ion-mixing of multilayers are analyzed. Oblique incident illumination causes streamers at absorber edges and causes position shifting in aerial images. The diffraction waves between ion-mixed and pristine multilayers are observed. The phase-shifting caused by stepped substrates is simulated and images show that it succeeds in creation of phase-shifting effects. The diffraction process at the phase boundary is also analyzed. As an example of EUV phase-shifting masks, a coma pattern and probe based aberration monitor is simulated and aerial images are formed under different levels of coma aberration. The probe signal rises quickly as coma increases as designed.

  15. Evaluation of a New Pediatric Positive Airway Pressure Mask

    PubMed Central

    Kushida, Clete A.; Halbower, Ann C.; Kryger, Meir H.; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J.; Mendoza, June

    2014-01-01

    Study Objectives: The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged < 7 years was not available. This study evaluated apnea-hypopnea index (AHI) equivalence and acceptability of a new pediatric CPAP mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Methods: Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. Results: AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. Conclusions: The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. Citation: Kushida CA, Halbower AC, Kryger MH, Pelayo R, Assalone V, Cardell CY, Huston S, Willes L, Wimms AJ, Mendoza J. Evaluation of a new pediatric positive airway pressure mask. J Clin Sleep Med 2014;10(9):979-984. PMID:25142768

  16. Set Size and Mask Duration Do Not Interact in Object-Substitution Masking

    ERIC Educational Resources Information Center

    Argyropoulos, Ioannis; Gellatly, Angus; Pilling, Michael; Carter, Wakefield

    2013-01-01

    Object-substitution masking (OSM) occurs when a mask, such as four dots that surround a brief target item, onsets simultaneously with the target and offsets a short time after the target, rather than simultaneously with it. OSM is a reduction in accuracy of reporting the target with the temporally trailing mask, compared with the simultaneously…

  17. [Ventilation during cardiopulmonary resuscitation in the infant. Mouth to mouth and nose, or bag-valve-mask? A quasi-experimental study].

    PubMed

    Santos-Folgar, Myriam; Otero-Agra, Martín; Fernández-Méndez, Felipe; Hermo-Gonzalo, María Teresa; Barcala-Furelos, Roberto; Rodríguez-Núñez, Antonio

    2018-02-08

    It has been observed that health professionals have difficulty performing quality cardiopulmonary resuscitation (CPR). The aim of this study was to compare the quality of ventilations performed by Nursing students on an infant model using different methods (mouth-to-mouth-and-nose or bag-valve-mask). A quasi-experimental cross-sectional study was performed that included 46 second-year Nursing students. Two quantitative 4-minute tests of paediatric CPR were performed: a) mouth-to-mouth-and-nose ventilations, and b) ventilations with bag-valve-mask. A Resusci Baby QCPR Wireless SkillReporter® mannequin from Laerdal was used. The proportion of ventilations with adequate, excessive, and insufficient volume was recorded and analysed, as well as the overall quality of the CPR (ventilations and chest compressions). The students were able to give a higher number of ventilations with adequate volume using the mouth-to-mouth-and-nose method (55±22%) than with the bag-valve-mask (28±16%, P<.001). The overall quality of the CPR was also significantly higher when using the mouth-to-mouth-and-nose method (60±19 vs. 48±16%, P<.001). Mouth-to-mouth-and-nose ventilation method is more efficient than bag-valve-mask ventilations in CPR performed by nursing students with a simulated infant model. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  18. SU-8 negative photoresist for optical mask manufacturing

    NASA Astrophysics Data System (ADS)

    Bogdanov, Alexei L.

    2000-06-01

    The requirements for better control, linearity, and uniformity of critical dimension (CD) on photomasks in fabrication of 180 and 150 nm generation devices result in increasing demand for thinner, more etching durable, and more sensitive e-beam resists. Novolac based resists with chemical amplification have been a choice for their sensitivity and stability during etching. However, difficult CD control due to the acid catalyzer diffusion and quite narrow post exposure bake (PEB) process window are some of the major drawbacks of these resists. SU-8 is recently introduced to the market negative photoresist. High sensitivity, fairly good adhesion properties, and relatively simple processing of SU-8 make it a good substitution for novolac based chemically amplified negative e-beam resists in optical mask manufacturing. The replacement of traditional chemically amplified resists by SU- 8 can increase the process latitude and reduce resist costs. Among the obvious drawbacks of SU-8 are the use of solvent- based developer and demand of oxygen plasma for resist removal. In this paper the use of SU-8 for optical mask manufacturing is reported. All steps of resist film preparation, exposure and development are paid a share of attention. Possibilities to use reactive ion etching (RIE) with oxygen in order to increase resist mask contrast are discussed. Special exposure strategy (pattern outlining) was employed to further improve the edge definition. The resist PEB temperature and time were studied to estimate their weight in overall CD control performance. Specially designed test patterns with 0.25 micrometer design rule could be firmly transferred into a chromium layer both by wet etching and ion milling. Influence of exposure dose variation on the pattern CD change was studied.

  19. EUVL mask dual pods to be used for mask shipping and handling in exposure tools

    NASA Astrophysics Data System (ADS)

    Gomei, Yoshio; Ota, Kazuya; Lystad, John; Halbmair, Dave; He, Long

    2007-03-01

    The concept of Extreme Ultra-Violet Lithography (EUVL) mask dual pods is proposed for use in both mask shipping and handling in exposure tools. The inner pod was specially designed to protect masks from particle contamination during shipping from mask houses to wafer factories. It can be installed in a load-lock chamber of exposure tools and evacuated while holding the mask inside. The inner pod upper cover is removed just before the mask is installed to a mask stage. Prototypes were manufactured and tested for shipping and for vacuum cycling. We counted particle adders through these actions with a detectable level of 54 nm and up. The adder count was close to zero, or we can say that the obtained result is within the noise level of our present evaluation environment. This indicates that the present concept is highly feasible for EUVL mask shipping and handling in exposure tools.

  20. Getting the cocktail party started: masking effects in speech perception

    PubMed Central

    Evans, S; McGettigan, C; Agnew, ZK; Rosen, S; Scott, SK

    2016-01-01

    Spoken conversations typically take place in noisy environments and different kinds of masking sounds place differing demands on cognitive resources. Previous studies, examining the modulation of neural activity associated with the properties of competing sounds, have shown that additional speech streams engage the superior temporal gyrus. However, the absence of a condition in which target speech was heard without additional masking made it difficult to identify brain networks specific to masking and to ascertain the extent to which competing speech was processed equivalently to target speech. In this study, we scanned young healthy adults with continuous functional Magnetic Resonance Imaging (fMRI), whilst they listened to stories masked by sounds that differed in their similarity to speech. We show that auditory attention and control networks are activated during attentive listening to masked speech in the absence of an overt behavioural task. We demonstrate that competing speech is processed predominantly in the left hemisphere within the same pathway as target speech but is not treated equivalently within that stream, and that individuals who perform better in speech in noise tasks activate the left mid-posterior superior temporal gyrus more. Finally, we identify neural responses associated with the onset of sounds in the auditory environment, activity was found within right lateralised frontal regions consistent with a phasic alerting response. Taken together, these results provide a comprehensive account of the neural processes involved in listening in noise. PMID:26696297

  1. Mask strategy at International SEMATECH

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.

    2002-08-01

    International SEMATECH (ISMT) is a consortium consisting of 13 leading semiconductor manufacturers from around the globe. Its objective is to develop the infrastructure necessary for its member companies to realize the International Technology Roadmap for Semiconductors (ITRS) through efficiencies of shared development resources and knowledge. The largest area of effort is lithography, recognized as a crucial enabler for microelectronics technology progress. Within the Lithography Division, most of the efforts center on mask-related issues. The development strategy at International SEMATCH will be presented and the interlock of lithography projects clarified. Because of the limited size of the mask production equipment market, the business case is weak for aggressive investment commensurate with the pace of the International Technology Roadmap for Semiconductors. With masks becoming the overwhelming component of lithography cost, new ways of reducing or eliminating mask costs are being explored. Will mask technology survive without a strong business case? Will the mask industry limit the growth of the semiconductor industry? Are advanced masks worth their escalating cost? An analysis of mask cost from the perspective of mask value imparted to the user is presented with examples and generic formulas for the reader to apply independently. A key part to the success for both International SEMATECH and the industry globally will be partnerships on both the local level between mask-maker and mask-user, and the macro level where global collaborations will be necessary to resolve technology development cost challenges.

  2. Informational masking and musical training

    NASA Astrophysics Data System (ADS)

    Oxenham, Andrew J.; Fligor, Brian J.; Mason, Christine R.; Kidd, Gerald

    2003-09-01

    The relationship between musical training and informational masking was studied for 24 young adult listeners with normal hearing. The listeners were divided into two groups based on musical training. In one group, the listeners had little or no musical training; the other group was comprised of highly trained, currently active musicians. The hypothesis was that musicians may be less susceptible to informational masking, which is thought to reflect central, rather than peripheral, limitations on the processing of sound. Masked thresholds were measured in two conditions, similar to those used by Kidd et al. [J. Acoust. Soc. Am. 95, 3475-3480 (1994)]. In both conditions the signal was comprised of a series of repeated tone bursts at 1 kHz. The masker was comprised of a series of multitone bursts, gated with the signal. In one condition the frequencies of the masker were selected randomly for each burst; in the other condition the masker frequencies were selected randomly for the first burst of each interval and then remained constant throughout the interval. The difference in thresholds between the two conditions was taken as a measure of informational masking. Frequency selectivity, using the notched-noise method, was also estimated in the two groups. The results showed no difference in frequency selectivity between the two groups, but showed a large and significant difference in the amount of informational masking between musically trained and untrained listeners. This informational masking task, which requires no knowledge specific to musical training (such as note or interval names) and is generally not susceptible to systematic short- or medium-term training effects, may provide a basis for further studies of analytic listening abilities in different populations.

  3. Tachistoscopic illumination and masking of real scenes

    PubMed Central

    Chichka, David; Philbeck, John W.; Gajewski, Daniel A.

    2014-01-01

    Tachistoscopic presentation of scenes has been valuable for studying the emerging properties of visual scene representations. The spatial aspects of this work have generally been focused on the conceptual locations (e.g., next to the refrigerator) and the directional locations of objects in 2D arrays and/or images. Less is known about how the perceived egocentric distance of objects develops. Here we describe a novel system for presenting brief glimpses of a real-world environment, followed by a mask. The system includes projectors with mechanical shutters for projecting the fixation and masking images, a set of LED floodlights for illuminating the environment, and computer-controlled electronics to set the timing and initiate the process. Because a real environment is used, most visual distance and depth cues may be manipulated using traditional methods. The system is inexpensive, robust, and its components are readily available in the marketplace. This paper describes the system and the timing characteristics of each component. Verification of the ability to control exposure to time scales as low as a few milliseconds is demonstrated. PMID:24519496

  4. Tachistoscopic illumination and masking of real scenes.

    PubMed

    Chichka, David; Philbeck, John W; Gajewski, Daniel A

    2015-03-01

    Tachistoscopic presentation of scenes has been valuable for studying the emerging properties of visual scene representations. The spatial aspects of this work have generally been focused on the conceptual locations (e.g., next to the refrigerator) and directional locations of objects in 2-D arrays and/or images. Less is known about how the perceived egocentric distance of objects develops. Here we describe a novel system for presenting brief glimpses of a real-world environment, followed by a mask. The system includes projectors with mechanical shutters for projecting the fixation and masking images, a set of LED floodlights for illuminating the environment, and computer-controlled electronics to set the timing and initiate the process. Because a real environment is used, most visual distance and depth cues can be manipulated using traditional methods. The system is inexpensive, robust, and its components are readily available in the marketplace. This article describes the system and the timing characteristics of each component. We verified the system's ability to control exposure to time scales as low as a few milliseconds.

  5. The pilus usher controls protein interactions via domain masking and is functional as an oligomer

    DOE PAGES

    Werneburg, Glenn T.; Li, Huilin; Henderson, Nadine S.; ...

    2015-06-08

    The chaperone/usher (CU) pathway is responsible for biogenesis of organelles termed pili or fimbriae in Gram-negative bacteria. Type 1 pili expressed by uropathogenic Escherichia coli are prototypical structures assembled by the CU pathway. Assembly and secretion of pili by the CU pathway requires a dedicated periplasmic chaperone and a multidomain outer membrane protein termed the usher (FimD). We show that the FimD C-terminal domains provide the high-affinity substrate binding site, but that these domains are masked in the resting usher. Domain masking requires the FimD plug domain, which served as a central switch controlling usher activation. In addition, we demonstratemore » that usher molecules can act in trans for pilus biogenesis, providing conclusive evidence for a functional usher oligomer. These results reveal mechanisms by which molecular machines such as the usher regulate and harness protein-protein interactions, and suggest that ushers may interact in a cooperative manner during pilus assembly in bacteria.« less

  6. The performances of standard and ResMed masks during bag-valve-mask ventilation.

    PubMed

    Lee, Hyoung Youn; Jeung, Kyung Woon; Lee, Byung Kook; Lee, Seung Joon; Jung, Yong Hun; Lee, Geo Sung; Min, Yong Il; Heo, Tag

    2013-01-01

    A tight mask seal is frequently difficult to obtain and maintain during single-rescuer bag-valve-mask (BVM) ventilation. The ResMed mask (Bella Vista, NSW, Australia) is a continuous-positive-airway-pressure mask (CM) designed for noninvasive ventilation. In this study, we compared the ventilation performances of a standard mask (SM) and a ResMed CM using a simulation manikin in an out-of-hospital single-rescuer BVM ventilation scenario. Thirty emergency medical technicians (EMTs) performed two 2-minute attempts to ventilate a simulation manikin using BVM ventilation, alternatively, with the SM or the ResMed CM in a randomized order. Ventilation parameters including tidal volume and peak airway pressure were measured using computer analysis software connected to the simulation manikin. Successful volume delivery was defined as delivery of 440-540 mL of tidal volume in accord with present cardiopulmonary resuscitation guidelines. BVM ventilation using the ResMed CM produced higher mean (± standard deviation) tidal volumes (452 ± 50 mL vs. 394 ± 113 mL, p = 0.014) and had a higher proportion of successful volume deliveries (65.3% vs. 26.7%, p < 0.001) than that using the SM. Peak airway pressure was higher in BVM ventilation using the ResMed CM (p = 0.035). Stomach insufflation did not occur during either method. Twenty-nine of the participants (96.7%) preferred BVM ventilation using the ResMed CM. BVM ventilations using ResMed CM resulted in a significantly higher proportion of successful volume deliveries meeting the currently recommended range of tidal volume. Clinical studies are needed to determine the value of the ResMed CM for BVM ventilation.

  7. Factors responsible for remote-frequency masking in children and adultsa)

    PubMed Central

    Leibold, Lori J.; Buss, Emily

    2016-01-01

    Susceptibility to remote-frequency masking in children and adults was evaluated with respect to three stimulus features: (1) masker bandwidth, (2) spectral separation of the signal and masker, and (3) gated versus continuous masker presentation. Listeners were 4- to 6-year-olds, 7- to 10-year-olds, and adults. Detection thresholds for a 500-ms, 2000-Hz signal were estimated in quiet or presented with a band of noise in one of four frequency regions: 425–500 Hz, 4000–4075 Hz, 8000–8075 Hz, or 4000–10 000 Hz. In experiment 1, maskers were gated on in each 500-ms interval of a three-interval, forced-choice adaptive procedure. Masking was observed for all ages in all maskers, but the greatest masking was observed for the 4000–4075 Hz masker. These findings suggest that signal/masker spectral proximity plays an important role in remote-frequency masking, even when peripheral excitation associated with the signal and masker does not overlap. Younger children tended to have more masking than older children or adults, consistent with a reduced ability to segregate simultaneous sounds and/or listen in a frequency-selective manner. In experiment 2, detection thresholds were estimated in the same noises, but maskers were presented continuously. Masking was reduced for all ages relative to gated conditions, suggesting improved segregation and/or frequency-selective listening. PMID:28040030

  8. Fabrication of rectangular cross-sectional microchannels on PMMA with a CO2 laser and underwater fabricated copper mask

    NASA Astrophysics Data System (ADS)

    Prakash, Shashi; Kumar, Subrata

    2017-09-01

    CO2 lasers are commonly used for fabricating polymer based microfluidic devices. Despite several key advantages like low cost, time effectiveness, easy to operate and no requirement of clean room facility, CO2 lasers suffer from few disadvantages like thermal bulging, improper dimensional control, difficulty to produce microchannels of other than Gaussian cross sectional shapes and inclined surface walls. Many microfluidic devices require square or rectangular cross-sections which are difficult to produce using normal CO2 laser procedures. In this work, a thin copper sheet of 40 μm was used as a mask above the PMMA (Polymethyl-methacrylate) substrate while fabricating the microchannels utilizing the raster scanning feature of the CO2 lasers. Microchannels with different width dimensions were fabricated utilizing a CO2 laser in with mask and without-mask conditions. A comparison of both the fabricating process has been made. It was found that microchannels with U shape cross section and rectangular cross-section can efficiently be produced using the with mask technique. In addition to this, this technique can provide perfect dimensional control and better surface quality of the microchannel walls. Such a microchannel fabrication process do not require any post-processing. The fabrication of mask using a nanosecond fiber laser has been discussed in details. An underwater laser fabrication method was adopted to overcome heat related defects in mask preparation. Overall, the technique was found to be easy to adopt and significant improvements were observed in microchannel fabrication.

  9. Masks in Pedagogical Practice

    ERIC Educational Resources Information Center

    Roy, David

    2016-01-01

    In Drama Education mask work is undertaken and presented as both a methodology and knowledge base. There are numerous workshops and journal articles available for teachers that offer knowledge or implementation of mask work. However, empirical examination of the context or potential implementation of masks as a pedagogical tool remains…

  10. Keeping African Masks Real

    ERIC Educational Resources Information Center

    Waddington, Susan

    2012-01-01

    Art is a good place to learn about our multicultural planet, and African masks are prized throughout the world as powerfully expressive artistic images. Unfortunately, multicultural education, especially for young children, can perpetuate stereotypes. Masks taken out of context lose their meaning and the term "African masks" suggests that there is…

  11. Spatial Release from Masking in Children: Effects of Simulated Unilateral Hearing Loss

    PubMed Central

    Corbin, Nicole E.; Buss, Emily; Leibold, Lori J.

    2016-01-01

    Objectives The purpose of this study was twofold: 1) to determine the effect of an acute simulated unilateral hearing loss on children’s spatial release from masking in two-talker speech and speech-shaped noise, and 2) to develop a procedure to be used in future studies that will assess spatial release from masking in children who have permanent unilateral hearing loss. There were three main predictions. First, spatial release from masking was expected to be larger in two-talker speech than speech-shaped noise. Second, simulated unilateral hearing loss was expected to worsen performance in all listening conditions, but particularly in the spatially separated two-talker speech masker. Third, spatial release from masking was expected to be smaller for children than for adults in the two-talker masker. Design Participants were 12 children (8.7 to 10.9 yrs) and 11 adults (18.5 to 30.4 yrs) with normal bilateral hearing. Thresholds for 50%-correct recognition of Bamford-Kowal-Bench sentences were measured adaptively in continuous two-talker speech or speech-shaped noise. Target sentences were always presented from a loudspeaker at 0° azimuth. The masker stimulus was either co-located with the target or spatially separated to +90° or −90° azimuth. Spatial release from masking was quantified as the difference between thresholds obtained when the target and masker were co-located and thresholds obtained when the masker was presented from +90° or − 90°. Testing was completed both with and without a moderate simulated unilateral hearing loss, created with a foam earplug and supra-aural earmuff. A repeated-measures design was used to compare performance between children and adults, and performance in the no-plug and simulated-unilateral-hearing-loss conditions. Results All listeners benefited from spatial separation of target and masker stimuli on the azimuth plane in the no-plug listening conditions; this benefit was larger in two-talker speech than in speech

  12. Masks in Imaging Flow Cytometry

    PubMed Central

    Dominical, Venina; Samsel, Leigh; McCoy, J. Philip

    2016-01-01

    Data analysis in imaging flow cytometry incorporates elements of flow cytometry together with other aspects of morphological analysis of images. A crucial early step in this analysis is the creation of a mask to distinguish the portion of the image upon which further examination of specified features can be performed. Default masks are provided by the manufacturer of the imaging flow cytometer but additional custom masks can be created by the individual user for specific applications. Flawed or inaccurate masks can have a substantial negative impact on the overall analysis of a sample, thus great care must be taken to ensure the accuracy of masks. Here we discuss various types of masks and cite examples of their use. Furthermore we provide our insight for how to approach selecting and assessing the optimal mask for a specific analysis. PMID:27461256

  13. The Effect of a Diving Mask on Intraocular Pressure in a Healthy Population.

    PubMed

    Goenadi, Catherina Josephine; Law, David Zhiwei; Lee, Jia Wen; Ong, Ee Lin; Chee, Wai Kitt; Cheng, Jason

    2016-01-01

    Swimming goggles increase the intraocular pressure (IOP) via the periorbital frame pressure and suction effect. In comparison, diving masks have a larger frame rim and incorporate the nose. The exact effect(s) of diving masks on IOP is unknown. This study evaluates the influence of diving masks on IOP in normal, healthy subjects. Tonometry was performed in both eyes of all subjects with an AVIA(®)Tono-Pen by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. Central corneal thickness (CCT) was also measured in each eye, using a contact pachymeter (OcuScan(®)Alcon). Forty eyes of 20 healthy volunteers (age 29.7 ± 9.3 years; range 21-52) were included. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn had been 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p $1003c; 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = -0.174, p = 0.283) or CCT (r = -0.123, p = 0.445). There was no increase in IOP after the diving mask had been worn. A small but statistically significant decrease in IOP was observed. This study demonstrates that unlike swimming goggles, the strap tension and frame pressure on the periorbital tissue from a diving mask does not increase IOP. Diving masks may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery.

  14. The Effect of a Diving Mask on Intraocular Pressure in a Healthy Population

    PubMed Central

    Goenadi, Catherina Josephine; Law, David Zhiwei; Lee, Jia Wen; Ong, Ee Lin; Chee, Wai Kitt; Cheng, Jason

    2016-01-01

    Purpose Swimming goggles increase the intraocular pressure (IOP) via the periorbital frame pressure and suction effect. In comparison, diving masks have a larger frame rim and incorporate the nose. The exact effect(s) of diving masks on IOP is unknown. This study evaluates the influence of diving masks on IOP in normal, healthy subjects. Methods Tonometry was performed in both eyes of all subjects with an AVIA®Tono-Pen by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. Central corneal thickness (CCT) was also measured in each eye, using a contact pachymeter (OcuScan®Alcon). Results Forty eyes of 20 healthy volunteers (age 29.7 ± 9.3 years; range 21–52) were included. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn had been 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p $1003c; 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = −0.174, p = 0.283) or CCT (r = −0.123, p = 0.445). Conclusion There was no increase in IOP after the diving mask had been worn. A small but statistically significant decrease in IOP was observed. This study demonstrates that unlike swimming goggles, the strap tension and frame pressure on the periorbital tissue from a diving mask does not increase IOP. Diving masks may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery. PMID:27462262

  15. Rebamipide (OPC-12759) in the treatment of dry eye: a randomized, double-masked, multicenter, placebo-controlled phase II study.

    PubMed

    Kinoshita, Shigeru; Awamura, Saki; Oshiden, Kazuhide; Nakamichi, Norihiro; Suzuki, Hiroyuki; Yokoi, Norihiko

    2012-12-01

    To investigate the dose response for efficacy of 1% and 2% rebamipide ophthalmic suspension compared with placebo in patients with dry eye. A randomized, double-masked, multicenter, placebo-controlled, parallel-group, dose-response phase II study. A total of 308 patients with dry eye. After a 2-week screening period, patients were randomized to receive placebo or 1% rebamipide or 2% rebamipide administered as 1 drop in each eye 4 times daily for 4 weeks. The primary objective end point was change in fluorescein corneal staining (FCS) score from baseline to last observation carried forward (LOCF). Secondary objective end points were lissamine green conjunctival staining (LGCS) score, tear film break-up time (TBUT), and the Schirmer's test. Secondary subjective end points included dry eye-related ocular symptoms (foreign body sensation, dryness, photophobia, eye pain, and blurred vision) score and patients' overall treatment impression score. Rebamipide dose response was observed in FCS, LGCS, and TBUT scores. Both 1% and 2% rebamipide were significantly more effective than the placebo in terms of the change from baseline to LOCF for FCS, LGCS, and TBUT scores. There was no significant difference between the rebamipide and placebo groups from baseline to LOCF in Schirmer's test values, and dose response was not observed. In the predefined dry eye subpopulation with a baseline FCS score of 10 to 15, the mean change from baseline in the 2% rebamipide group was larger than that in the 1% rebamipide group. Change from baseline to LOCF for all 5 dry eye-related ocular symptom scores and patients' overall treatment impression showed significant improvements in the 1% and 2% rebamipide groups compared with the placebo group, except for photophobia in the 1% rebamipide group. No deaths or drug-related serious adverse events occurred in any treatment group. The incidence of ocular abnormalities was similar across the rebamipide and placebo groups. Rebamipide was effective in

  16. Dynamic mask for producing uniform or graded-thickness thin films

    DOEpatents

    Folta, James A [Livermore, CA

    2006-06-13

    A method for producing single layer or multilayer films with high thickness uniformity or thickness gradients. The method utilizes a moving mask which blocks some of the flux from a sputter target or evaporation source before it deposits on a substrate. The velocity and position of the mask is computer controlled to precisely tailor the film thickness distribution. The method is applicable to any type of vapor deposition system, but is particularly useful for ion beam sputter deposition and evaporation deposition; and enables a high degree of uniformity for ion beam deposition, even for near-normal incidence of deposition species, which may be critical for producing low-defect multilayer coatings, such as required for masks for extreme ultraviolet lithography (EUVL). The mask can have a variety of shapes, from a simple solid paddle shape to a larger mask with a shaped hole through which the flux passes. The motion of the mask can be linear or rotational, and the mask can be moved to make single or multiple passes in front of the substrate per layer, and can pass completely or partially across the substrate.

  17. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes.

    PubMed

    Rafferty, Anthony Richard; Johnson, Lucy; Davis, Peter G; Dawson, Jennifer Anne; Thio, Marta; Owen, Louise S

    2017-11-30

    Neonatal mask ventilation is a difficult skill to acquire and maintain. Mask leak is common and can lead to ineffective ventilation. The aim of this study was to determine whether newly available neonatal self-inflating bags and masks could reduce mask leak without additional load being applied to the face. Forty operators delivered 1 min episodes of mask ventilation to a mannequin using the Laerdal Upright Resuscitator, a standard Laerdal infant resuscitator (Laerdal Medical) and a T-Piece Resuscitator (Neopuff), using both the Laerdal snap-fit face mask and the standard Laerdal size 0/1 face mask (equivalent sizes). Participants were asked to use pressure sufficient to achieve 'appropriate' chest rise. Leak, applied load, airway pressure and tidal volume were measured continuously. Participants were unaware that load was being recorded. There was no difference in mask leak between resuscitation devices. Leak was significantly lower when the snap-fit mask was used with all resuscitation devices, compared with the standard mask (14% vs 37% leak, P<0.01). The snap-fit mask was preferred by 83% of participants. The device-mask combinations had no significant effect on applied load. The Laerdal Upright Resuscitator resulted in similar leak to the other resuscitation devices studied, and did not exert additional load to the face and head. The snap-fit mask significantly reduced overall leak with all resuscitation devices and was the mask preferred by participants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Mask-Assisted Seeded Growth of Segmented Metallic Heteronanostructures

    DOE PAGES

    Crane, Cameron C.; Tao, Jing; Wang, Feng; ...

    2014-12-04

    Controlling the deposition of exotic metals in the seeded growth of multi-metal nanostructures is challenging. This work describes a seeded growth method assisted by a mask for synthesis of segmented binary or ternary metal nanostructures. Silica is used as a mask to partially block the surface of a seed and a second metal is subsequently deposited on the exposed area, forming a bimetallic heterodimer. The initial demonstration was carried out on a Au seed, followed by deposition of Pd or Pt on the seed. It was found that Pd tends to spread out laterally on the seed while Pt inclinesmore » to grow vertically into branched topology on Au. Without removal of the SiO₂ mask, Pt could be further deposited on the unblocked Pd of the Pd-Au dimer to form a Pt-Pd-Au trimer. The mask-assisted seeded growth provides a general strategy to construct segmented metallic nanoarchitectures.« less

  19. Moving stimuli are less effectively masked using traditional continuous flash suppression (CFS) compared to a moving Mondrian mask (MMM): a test case for feature-selective suppression and retinotopic adaptation.

    PubMed

    Moors, Pieter; Wagemans, Johan; de-Wit, Lee

    2014-01-01

    Continuous flash suppression (CFS) is a powerful interocular suppression technique, which is often described as an effective means to reliably suppress stimuli from visual awareness. Suppression through CFS has been assumed to depend upon a reduction in (retinotopically specific) neural adaptation caused by the continual updating of the contents of the visual input to one eye. In this study, we started from the observation that suppressing a moving stimulus through CFS appeared to be more effective when using a mask that was actually more prone to retinotopically specific neural adaptation, but in which the properties of the mask were more similar to those of the to-be-suppressed stimulus. In two experiments, we find that using a moving Mondrian mask (i.e., one that includes motion) is more effective in suppressing a moving stimulus than a regular CFS mask. The observed pattern of results cannot be explained by a simple simulation that computes the degree of retinotopically specific neural adaptation over time, suggesting that this kind of neural adaptation does not play a large role in predicting the differences between conditions in this context. We also find some evidence consistent with the idea that the most effective CFS mask is the one that matches the properties (speed) of the suppressed stimulus. These results question the general importance of retinotopically specific neural adaptation in CFS, and potentially help to explain an implicit trend in the literature to adapt one's CFS mask to match one's to-be-suppressed stimuli. Finally, the results should help to guide the methodological development of future research where continuous suppression of moving stimuli is desired.

  20. Comodulation masking release in an off-frequency masking paradigm.

    PubMed

    Grzeschik, Ramona; Lübken, Björn; Verhey, Jesko L

    2015-08-01

    Detection threshold of a sinusoidal signal masked by a broadband masker is lower when on- and off-frequency masker components have a correlated envelope, compared to a condition in which these masker components have different envelopes. This effect is commonly referred to as comodulation masking release (CMR). The present study investigated if there is a CMR in the absence of a masker component at the signal frequency, i.e., in an off-frequency masking paradigm. Thresholds were measured for a 500-Hz signal in the presence of a broadband masker with a spectral notch at the signal frequency. Thresholds were significantly lower for a (co-)modulated than for an unmodulated masker for all notch widths up to 400 Hz. An additional experiment showed that the particularly large CMR for the no-notch condition was due to the way the modulated masker was generated. No CMR was measured when the notched-noise masker was replaced by a pair of narrowband noises. The addition of more remote masker bands resulted in a CMR of about 3-4 dB. The notched-noise data were predicted on the basis of a modulation-filterbank model. The predictions of the narrowband noise conditions indicated that all mechanisms underlying CMR might still not be fully understood.

  1. The influence of facial masking and sex on older adults' impressions of individuals with Parkinson's disease.

    PubMed

    Hemmesch, Amanda R; Tickle-Degnen, Linda; Zebrowitz, Leslie A

    2009-09-01

    Parkinson's disease (PD) involves facial masking, which may impair social interaction. Older adult observers who viewed segments of videotaped interviews of individuals with PD expressed less interest in relationships with women with higher masking and judged them as less supportive. Masking did not affect ratings of men in these domains, possibly because higher masking violates gender norms for expressivity in women but not in men. Observers formed less accurate ratings of the social supportiveness and social strain of women than men, and higher masking decreased accuracy for ratings of strain. Results suggest that some of the problems with social relationships in PD may be due to inaccurate impressions and reduced desire to interact with individuals with higher masking, especially women. (c) 2009 APA, all rights reserved.

  2. Masks: The Artist in Me

    ERIC Educational Resources Information Center

    Skophammer, Karen

    2009-01-01

    Whether masks are made from cardboard, papier-mache, metal, wood, leather, fabric, clay or any combination of these materials, they bring out the artist in people. Young children like to wear masks when they play to pretend they were another person or animal. Masks let them fantasize and be creative. The author's students made masks representing…

  3. Object Substitution Masking Induced by Illusory Masks: Evidence for Higher Object-Level Locus of Interference

    ERIC Educational Resources Information Center

    Hirose, Nobuyuki; Osaka, Naoyuki

    2009-01-01

    A briefly presented target can be rendered invisible by a lingering sparse mask that does not even touch it. This form of visual backward masking, called object substitution masking, is thought to occur at the object level of processing. However, it remains unclear whether object-level interference alone produces substitution masking because…

  4. Objective measures of binaural masking level differences and comodulation masking release based on late auditory evoked potentials.

    PubMed

    Epp, Bastian; Yasin, Ifat; Verhey, Jesko L

    2013-12-01

    The audibility of important sounds is often hampered due to the presence of other masking sounds. The present study investigates if a correlate of the audibility of a tone masked by noise is found in late auditory evoked potentials measured from human listeners. The audibility of the target sound at a fixed physical intensity is varied by introducing auditory cues of (i) interaural target signal phase disparity and (ii) coherent masker level fluctuations in different frequency regions. In agreement with previous studies, psychoacoustical experiments showed that both stimulus manipulations result in a masking release (i: binaural masking level difference; ii: comodulation masking release) compared to a condition where those cues are not present. Late auditory evoked potentials (N1, P2) were recorded for the stimuli at a constant masker level, but different signal levels within the same set of listeners who participated in the psychoacoustical experiment. The data indicate differences in N1 and P2 between stimuli with and without interaural phase disparities. However, differences for stimuli with and without coherent masker modulation were only found for P2, i.e., only P2 is sensitive to the increase in audibility, irrespective of the cue that caused the masking release. The amplitude of P2 is consistent with the psychoacoustical finding of an addition of the masking releases when both cues are present. Even though it cannot be concluded where along the auditory pathway the audibility is represented, the P2 component of auditory evoked potentials is a candidate for an objective measure of audibility in the human auditory system. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. X-ray mask and method for making

    DOEpatents

    Morales, Alfredo M.

    2004-10-26

    The present invention describes a method for fabricating an x-ray mask tool which is a contact lithographic mask which can provide an x-ray exposure dose which is adjustable from point-to-point. The tool is useful in the preparation of LIGA plating molds made from PMMA, or similar materials. In particular the tool is useful for providing an ability to apply a graded, or "stepped" x-ray exposure dose across a photosensitive substrate. By controlling the x-ray radiation dose from point-to-point, it is possible to control the development process for removing exposed portions of the substrate; adjusting it such that each of these portions develops at a more or less uniformly rate regardless of feature size or feature density distribution.

  6. Challenges and requirements of mask data processing for multi-beam mask writer

    NASA Astrophysics Data System (ADS)

    Choi, Jin; Lee, Dong Hyun; Park, Sinjeung; Lee, SookHyun; Tamamushi, Shuichi; Shin, In Kyun; Jeon, Chan Uk

    2015-07-01

    To overcome the resolution and throughput of current mask writer for advanced lithography technologies, the platform of e-beam writer have been evolved by the developments of hardware and software in writer. Especially, aggressive optical proximity correction (OPC) for unprecedented extension of optical lithography and the needs of low sensitivity resist for high resolution result in the limit of variable shaped beam writer which is widely used for mass production. The multi-beam mask writer is attractive candidate for photomask writing of sub-10nm device because of its high speed and the large degree of freedom which enable high dose and dose modulation for each pixel. However, the higher dose and almost unlimited appetite for dose modulation challenge the mask data processing (MDP) in aspects of extreme data volume and correction method. Here, we discuss the requirements of mask data processing for multi-beam mask writer and presents new challenges of the data format, data flow, and correction method for user and supplier MDP tool.

  7. Green binary and phase shifting mask

    NASA Astrophysics Data System (ADS)

    Shy, S. L.; Hong, Chao-Sin; Wu, Cheng-San; Chen, S. J.; Wu, Hung-Yu; Ting, Yung-Chiang

    2009-12-01

    SixNy/Ni thin film green mask blanks were developed , and are now going to be used to replace general chromium film used for binary mask as well as to replace molydium silicide embedded material for AttPSM for I-line (365 nm), KrF (248 nm), ArF (193 nm) and Contact/Proximity lithography. A bilayer structure of a 1 nm thick opaque, conductive nickel layer and a SixNy layer is proposed for binary and phase-shifting mask. With the good controlling of plasma CVD of SixNy under silane (50 sccm), ammonia (5 sccm) and nitrogen (100 sccm), the pressure is 250 mTorr. and RF frequency 13.56 MHz and power 50 W. SixNy has enough deposition latitude to meet the requirements as an embedded layer for required phase shift 180 degree, and the T% in 193, 248 and 365 nm can be adjusted between 2% to 20% for binary and phase shifting mask usage. Ni can be deposited by E-gun, its sheet resistance Rs is less than 1.435 kΩ/square. Jeol e-beam system and I-line stepper are used to evaluate these thin film green mask blanks, feature size less than 200 nm half pitch pattern and 0.558 μm pitch contact hole can be printed. Transmission spectrums of various thickness of SixNy film are inspected by using UV spectrometer and FTIR. Optical constants of the SixNy film are measured by n & k meter and surface roughness is inspected by using Atomic Force Microscope (AFM).

  8. Evaluation of a new pediatric positive airway pressure mask.

    PubMed

    Kushida, Clete A; Halbower, Ann C; Kryger, Meir H; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J; Mendoza, June

    2014-09-15

    The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged < 7 years was not available. This study evaluated apnea-hypopnea index (AHI) equivalence and acceptability of a new pediatric CPAP mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. © 2014 American Academy of Sleep Medicine.

  9. Preparation of orally disintegrating tablets with taste-masking function: masking effect in granules prepared with correctives using the dry granulation method and evaluation of tablets prepared using the taste-masked granules.

    PubMed

    Kawano, Yayoi; Ito, Akihiko; Sasatsu, Masanaho; Machida, Yoshiharu

    2010-01-01

    We investigated several methods of taste masking in the preparation of orally disintegrating tablets (ODTs), using furosemide (FU) as a model drug. Four types of FU preparations were prepared: granules with maltitol (MA), granules with yogurt powder (YO), a physical mixture of FU and MA, and a physical mixture of FU and YO. All taste-masking granules were prepared using the dry granulation method. The taste of each type of preparation was evaluated. All four preparations markedly improved the taste of the FU tablets, but the mixing ratios of the correctives did not affect the masking effect. No difference in masking effect was found between MA and YO in the physical mixtures, but the masking effect in the granules with YO was superior to that of the granules with MA. Taste-masked FU tablets were prepared using the direct compression method; crystalline cellulose (Avicel PH-302) and mannitol were added as excipients at the mixing ratio of 1/1. All four types of tablets displayed sufficient hardness, but MA-containing tablets were harder than YO-containing tablets. The hardness of the tablets prepared from YO granules increased as the YO content increased. The most rapidly disintegrating tablets were those of YO granules prepared at a mixing ratio of FU/YO=1/1, which disintegrated within 20 s, followed by the tablets of MA granules prepared at a mixing ratio of FU/MA=1/1. The disintegration times of the tablets made from physical mixtures, in contrast, were longer than 200 s. Disintegration time lengthened as the mixing ratio of YO or MA increased. The hardness and disintegration time of these tablets could be controlled by varying the compression pressure. We found that YO is more useful than MA in masking unpleasant tastes and confirmed that orally disintegrating tablets with taste-masking function can be prepared using granules of YO prepared using the dry granulation method as a new corrective.

  10. Gestalt grouping and common onset masking.

    PubMed

    Kahan, Todd A; Mathis, Katherine M

    2002-11-01

    A four-dot mask that surrounds and is presented simultaneously with a briefly presented target will reduce a person's ability to identity that target if the mask persists beyond target offset and attention is divided (Enns & Di Lollo, 1997, 2000). This masking effect, referred to as common onset masking, reflects reentrant processing in the visual system and can best be explained with a theory of object substitution (Di Lollo, Enns, & Rensink, 2000). In the present experiments, we investigated whether Gestalt grouping variables would influence the strength of common onset masking. The results indicated that (1) masking was impervious to grouping by form, similarity of color, position, luminance polarity, and common region and (2) masking increased with the number of elements in the masking display.

  11. Photorefractive keratectomy (PRK) at 193 nm using an erodible mask: new developments and clinical progress

    NASA Astrophysics Data System (ADS)

    Gordon, Michael; Seiler, Theo; Carey, Joseph P.; Friedman, Marc D.; Johnsson, N. M. F.; King, Michael C.; Muller, David F.

    1993-06-01

    This paper reports on our progress using an erodible mask to perform photorefractive keratectomy (PRK) for the correction of myopic astigmatism. We describe modifications to the mask, the mask eye cup and the surgical microscope aimed at simplifying the procedure and improving the ergonomics of the hardware. We report the clinical results of the post-op exam for 20 patients who have undergone PRK for myopic astigmatism under a Phase IIA study. The results compare favorably with an earlier Phase IIA study for performing PRK with a computer-controlled iris. Most important, the clinical data show the absence of any significant corneal haze and no significant decrease in spectacle corrected visual acuity. Although more long term follow-up is needed, the preliminary results support the safety and effectiveness of using an erodible mask to perform PRK for myopic astigmatism.

  12. The bright-star masks for the HSC-SSP survey

    NASA Astrophysics Data System (ADS)

    Coupon, Jean; Czakon, Nicole; Bosch, James; Komiyama, Yutaka; Medezinski, Elinor; Miyazaki, Satoshi; Oguri, Masamune

    2018-01-01

    We present the procedure to build and validate the bright-star masks for the Hyper-Suprime-Cam Strategic Subaru Proposal (HSC-SSP) survey. To identify and mask the saturated stars in the full HSC-SSP footprint, we rely on the Gaia and Tycho-2 star catalogues. We first assemble a pure star catalogue down to GGaia < 18 after removing ˜1.5% of sources that appear extended in the Sloan Digital Sky Survey (SDSS). We perform visual inspection on the early data from the S16A internal release of HSC-SSP, finding that our star catalogue is 99.2% pure down to GGaia < 18. Second, we build the mask regions in an automated way using stacked detected source measurements around bright stars binned per GGaia magnitude. Finally, we validate those masks by visual inspection and comparison with the literature of galaxy number counts and angular two-point correlation functions. This version (Arcturus) supersedes the previous version (Sirius) used in the S16A internal and DR1 public releases. We publicly release the full masks and tools to flag objects in the entire footprint of the planned HSC-SSP observations at "ftp://obsftp.unige.ch/pub/coupon/brightStarMasks/HSC-SSP/".

  13. Conceptual Masking: How One Picture Captures Attention from Another Picture.

    ERIC Educational Resources Information Center

    Loftus, Geoffrey R.; And Others

    1988-01-01

    Five experiments studied operations of conceptual masking--the reduction of conceptual memory performance for an initial stimulus when it is followed by a masking picture process. The subjects were 337 undergraduates at the University of Washington (Seattle). Conceptual masking is distinguished from perceptual masking. (TJH)

  14. Bubble masks for time-encoded imaging of fast neutrons.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brubaker, Erik; Brennan, James S.; Marleau, Peter

    2013-09-01

    Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is inducedtypically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixedmore » blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gapsbubblespropagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.« less

  15. FIRST, a fibered aperture masking instrument: Results of the Lick observing campaign

    NASA Astrophysics Data System (ADS)

    Bordwell, Baylee; Duchene, Gaspard; Huby, Elsa; Goebel, Sean; Marchis, Franck; Perrin, Guy; Lacour, Sylvestre; Kotani, Takayuki; Gates, Elinor L.; Choquet, Elodie

    2015-01-01

    FIRST is a prototype instrument aimed at achieving high dynamic range and angular resolution in ground-based images at visible wavelengths near the diffraction limit. FIRST utilizes an aperture masking-like technique that makes use of single-mode fibers and pupil remapping to maximize the area of the telescope mirror in use. While located at Lick observatory in 2011 and 2012, FIRST observed 25 binary systems with the Shane 3m telescope, with separations ranging from 20 to 200 mas, comparable to the 50 mas diffraction limit for our central wavelength. Huby et al. (2013) has reported results for the Capella system that established the utility of FIRST for characterizing stellar binaries using the directly measured spectral flux ratio. Using an improved data analysis pipeline, we obtained closure phase measurements for a majority of the targets observed at Lick, and derived angular separations and spectral flux ratios. From the spectral flux ratios we obtained spectra for the companions over at least 600-850 nm with R~300. Finally, by obtaining results for many binary systems we have better constrained the current performance of FIRST, which has an exciting future ahead at its current location behind SCExAO at the Subaru 8.2 m telescope, where it will eventually become available for general use by the astronomical community.

  16. Calibration of a Spatial-Temporal Discrimination Model from Forward, Simultaneous, and Backward Masking

    NASA Technical Reports Server (NTRS)

    Ahumada, Albert J.; Beard, B. L.; Stone, Leland (Technical Monitor)

    1997-01-01

    We have been developing a simplified spatial-temporal discrimination model similar to our simplified spatial model in that masking is assumed to be a function of the local visible contrast energy. The overall spatial-temporal sensitivity of the model is calibrated to predict the detectability of targets on a uniform background. To calibrate the spatial-temporal integration functions that define local visible contrast energy, spatial-temporal masking data are required. Observer thresholds were measured (2IFC) for the detection of a 12 msec target stimulus in the presence of a 700 msec mask. Targets were 1, 3 or 9 c/deg sine wave gratings. Masks were either one of these gratings or two of them combined. The target was presented in 17 temporal positions with respect to the mask, including positions before, during and after the mask. Peak masking was found near mask onset and offset for 1 and 3 c/deg targets, while masking effects were more nearly uniform during the mask for the 9 c/deg target. As in the purely spatial case, the simplified model can not predict all the details of masking as a function of masking component spatial frequencies, but overall the prediction errors are small.

  17. Mask Industry Assessment: 2011

    NASA Astrophysics Data System (ADS)

    Chan, Y. David

    2011-11-01

    A survey supported by SEMATECH and administered by David Powell Consulting was sent to microelectronics industry leaders to gather information about the mask industry as an objective assessment of its overall condition. The survey was designed with the input of semiconductor company mask technologists and merchant mask suppliers. This year's assessment is the tenth in the current series of annual reports. With ongoing industry support, the report has been used as one of the baselines to gain perspective on the technical and business status of the mask and microelectronics industries. It continues to serve as a valuable reference to identify the strengths and opportunities of the mask industry. The results will be used to guide future investments pertaining to critical path issues. This year's survey was essentially the same as the 2005 through 2010 surveys. Questions are grouped into following categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the critical mask industry. This profile combined with the responses to past surveys represents a comprehensive view of changes in the industry.

  18. Mask Industry Assessment: 2010

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Chan, David Y.

    2010-09-01

    A survey created supported by SEMATECH and administered by David Powell Consulting was sent to microelectronics industry leaders to gather information about the mask industry as an objective assessment of its overall condition. The survey was designed with the input of semiconductor company mask technologists and merchant mask suppliers. This year's assessment is the ninth in the current series of annual reports. With ongoing industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. It will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. The results will be used to guide future investments pertaining to critical path issues. This year's survey was basically the same as the 2005 through 2009 surveys. Questions are grouped into categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the critical mask industry. This profile combined with the responses to past surveys represents a comprehensive view of changes in the industry.

  19. How Does Target Duration Affect Object Substitution Masking?

    ERIC Educational Resources Information Center

    Gellatly, Angus; Pilling, Michael; Carter, Wakefield; Guest, Duncan

    2010-01-01

    Object substitution masking (OSM) is typically studied using a brief search display. The target item may be indicated by a cue/mask surrounding but not overlapping it. Report of the target is reduced when mask offset trails target offset rather than being simultaneous with it. We report 5 experiments investigating whether OSM can be obtained if…

  20. Analysis of the ability of catcher's masks to attenuate head accelerations on impact with a baseball.

    PubMed

    Shain, Kellen S; Madigan, Michael L; Rowson, Steven; Bisplinghoff, Jill; Duma, Stefan M

    2010-11-01

    The goals of this study were to measure the ability of catcher's masks to attenuate head accelerations on impact with a baseball and to compare these head accelerations to established injury thresholds for mild traumatic brain injury. Testing involved using a pneumatic cannon to shoot baseballs at an instrumented Hybrid III headform (a 50th percentile male head and neck) with and without a catcher's mask on the head. The ball speed was controlled from approximately 26.8 to 35.8 m/s (60-80 mph), and the regulation National Collegiate Athletic Association baseballs were used. Research laboratory. None. Catcher's masks and impact velocity. The linear and angular head accelerations of the Hybrid III headform. Peak linear resultant acceleration was 140 to 180 g without a mask and 16 to 30 g with a mask over the range of ball's speed investigated. Peak angular resultant acceleration was 19 500 to 25 700 rad/s without a mask and 2250 to 3230 rad/s with a mask. The Head Injury Criterion was 93 to 181 without a mask and 3 to 13 with a mask, and the Severity Index was 110 to 210 without a mask and 3 to 15 with a mask. Catcher's masks reduced head acceleration metrics by approximately 85%. Head acceleration metrics with a catcher's mask were significantly lower than contemporary injury thresholds, yet reports in the mass media clearly indicate that baseball impacts to the mask still occasionally result in mild traumatic brain injuries. Further research is needed to address this apparent contradiction.

  1. Oronasal mask may compromise the efficacy of continuous positive airway pressure on OSA treatment: is there evidence for avoiding the oronasal route?

    PubMed

    Andrade, Rafaela Garcia Santos; Madeiro, Fernanda; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2016-11-01

    Continuous positive airway pressure (CPAP) delivered by nasal mask is the gold standard treatment for obstructive sleep apnea (OSA). However, oral and oronasal masks are also available. We considered experimental evidence and reviewed clinical trials that evaluated the impact of oral and oronasal mask on OSA treatment. One recent study in 18 OSA patients that slept with a customized oronasal mask with two sealed compartments showed that the change of CPAP flow from nasal to oronasal and oral caused upper airway obstruction because of posterior displacement of the tongue demonstrated by nasoendoscopy. Oral masks use a mouthpiece that may stabilize the jaw and the tongue and have shown to be effective. However, oral masks are not widely used in clinical practice. Four out of five observational studies and all five reviewed randomized studies showed a worse performance of oronasal when compared with nasal masks. Oronasal masks were associated with higher residual apnea-hypopnea index, lower adherence, more leaks, and less satisfaction than nasal mask in the majority of the studies. Nasal CPAP must be the first choice to treat OSA. Patients on oronasal mask should be carefully followed. VIDEO ABSTRACT.

  2. Designs and Materials for Better Coronagraph Occulting Masks

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatham

    2010-01-01

    New designs, and materials appropriate for such designs, are under investigation in an effort to develop coronagraph occulting masks having broad-band spectral characteristics superior to those currently employed. These designs and materials are applicable to all coronagraphs, both ground-based and spaceborne. This effort also offers potential benefits for the development of other optical masks and filters that are required (1) for precisely tailored spatial transmission profiles, (2) to be characterized by optical-density neutrality and phase neutrality (that is, to be characterized by constant optical density and constant phase over broad wavelength ranges), and/or (3) not to exhibit optical- density-dependent phase shifts. The need for this effort arises for the following reasons: Coronagraph occulting masks are required to impose, on beams of light transmitted through them, extremely precise control of amplitude and phase according to carefully designed transmission profiles. In the original application that gave rise to this effort, the concern has been to develop broad-band occulting masks for NASA s Terrestrial Planet Finder coronagraph. Until now, experimental samples of these masks have been made from high-energy-beam-sensitive (HEBS) glass, which becomes locally dark where irradiated with a high-energy electron beam, the amount of darkening depending on the electron-beam energy and dose. Precise mask profiles have been written on HEBS glass blanks by use of electron beams, and the masks have performed satisfactorily in monochromatic light. However, the optical-density and phase profiles of the HEBS masks vary significantly with wavelength; consequently, the HEBS masks perform unsatisfactorily in broad-band light. The key properties of materials to be used in coronagraph occulting masks are their extinction coefficients, their indices of refraction, and the variations of these parameters with wavelength. The effort thus far has included theoretical

  3. Masked Repetition Priming Treatment for Anomia

    ERIC Educational Resources Information Center

    Silkes, JoAnn P.

    2018-01-01

    Purpose: Masked priming has been suggested as a way to directly target implicit lexical retrieval processes in aphasia. This study was designed to investigate repeated use of masked repetition priming to improve picture naming in individuals with anomia due to aphasia. Method: A single-subject, multiple-baseline design was used across 6 people…

  4. A conceptual approach to the masking effect of measures of disproportionality.

    PubMed

    Maignen, Francois; Hauben, Manfred; Hung, Eric; Holle, Lionel Van; Dogne, Jean-Michel

    2014-02-01

    Masking is a statistical issue by which true signals of disproportionate reporting are hidden by the presence of other products in the database. Masking is currently not perfectly understood. There is no algorithm to identify the potential masking drugs to remove them for subsequent analyses of disproportionality. The primary objective of our study is to develop a mathematical framework for assessing the extent and impact of the masking effect of measures of disproportionality. We have developed a masking ratio that quantifies the masking effect of a given product. We have conducted a simulation study to validate our algorithm. The masking ratio is a measure of the strength of the masking effect whether the analysis is performed at the report or event level, and the manner in which reports are allocated to cells in the contingency table significantly impact the masking mechanisms. The reports containing both the product of interest and the masking product need to be handled appropriately. The proposed algorithm can use simplified masking provided that underlying assumptions (in particular the size of the database) are verified. For any event, the strongest masking effect is associated with the drug with the highest number of records (reports excluding the product of interest). Our study provides significant insights with practical implications for real-world pharmacovigilance that are supported by both real and simulated data. The public health impact of masking is still unknown. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Effects of Cueing in Auditory Temporal Masking

    ERIC Educational Resources Information Center

    Zhang, Ting; Formby, Craig

    2007-01-01

    Purpose: In a landmark study, B. A. Wright et al. (1997) reported an apparent backward-masking deficit in language-learning-impaired children. Subsequently, the controversial interpretation of those results has been influential in guiding treatments for childhood language problems. This study revisited the temporal-masking paradigm reported by B.…

  6. Masked mycotoxins: A review

    PubMed Central

    Berthiller, Franz; Crews, Colin; Dall'Asta, Chiara; Saeger, Sarah De; Haesaert, Geert; Karlovsky, Petr; Oswald, Isabelle P; Seefelder, Walburga; Speijers, Gerrit; Stroka, Joerg

    2013-01-01

    The aim of this review is to give a comprehensive overview of the current knowledge on plant metabolites of mycotoxins, also called masked mycotoxins. Mycotoxins are secondary fungal metabolites, toxic to human and animals. Toxigenic fungi often grow on edible plants, thus contaminating food and feed. Plants, as living organisms, can alter the chemical structure of mycotoxins as part of their defence against xenobiotics. The extractable conjugated or non-extractable bound mycotoxins formed remain present in the plant tissue but are currently neither routinely screened for in food nor regulated by legislation, thus they may be considered masked. Fusarium mycotoxins (deoxynivalenol, zearalenone, fumonisins, nivalenol, fusarenon-X, T-2 toxin, HT-2 toxin, fusaric acid) are prone to metabolisation or binding by plants, but transformation of other mycotoxins by plants (ochratoxin A, patulin, destruxins) has also been described. Toxicological data are scarce, but several studies highlight the potential threat to consumer safety from these substances. In particular, the possible hydrolysis of masked mycotoxins back to their toxic parents during mammalian digestion raises concerns. Dedicated chapters of this article address plant metabolism as well as the occurrence of masked mycotoxins in food, analytical aspects for their determination, toxicology and their impact on stakeholders. PMID:23047235

  7. Designing to win in sub-90nm mask production

    NASA Astrophysics Data System (ADS)

    Zhang, Yuan

    2005-11-01

    An informal survey conducted with key customers by Photronics indicates that the time gap between technology nodes has accelerated in recent years. Previously the cycle was three years. However, between 130nm and 90nm there was less than a 2 year gap, and between 90nm and 65nm a 1.5 year gap exists. As a result, the technical challenges have increased substantially. In addition, mask costs are rising exponentially due to high capital equipment cost, a shrinking customer base, long write times and increased applications of 193nm EAPSM or AAPSM. Collaboration among EDA companies, mask houses and wafer manufacturers is now more important than ever. This paper will explore avenues for reducing mask costs, mainly in the areas of: write-time reduction through design for manufacturing (DFM), and yield improvement through specification relaxation. Our study conducted through layout vertex modeling suggests that a simple design shape such as a square versus a circle or an angled structure helps reduce shot count and write time. Shot count reduction through mask layout optimization, and advancement in new generation E-beam writers can reduce write time up to 65%. An advanced laser writer can produce those less critical E-beam layers in less than half the time of an e-beam writer. Additionally, the emerging imprint lithography brings new life and new challenges to the photomask industry with applications in many fields outside of the semiconductor industry. As immersion lithography is introduced for 45nm device production, polarization and MEEF effects due to the mask will become severe. Larger magnification not only provides benefits on CD control and MEEF, but also extends the life time of current 90nm/65nm tool sets where 45nm mask sets can be produced at a lower cost.

  8. Mask quality assessment

    NASA Astrophysics Data System (ADS)

    Regis, Larry; Paulson, Neil; Reynolds, James A.

    1994-02-01

    Product quality and timely delivery are two of the most important parameters, determining the success of a mask manufacturing facility. Because of the sensitivity of this data, however, very little is known about industry performance in these areas. Using Arthur Andersen & Co. to protect contributor identity, the authors have conducted a blind quality survey of mask shops which represents over 75% of the total merchant and captive mask volume in the US. Quantities such as return rate, plate survival yield, performance to schedule and reason for return were requested from 1988 through Q2 1993. Data is analyzed and conclusions are presented.

  9. High-emulation mask recognition with high-resolution hyperspectral video capture system

    NASA Astrophysics Data System (ADS)

    Feng, Jiao; Fang, Xiaojing; Li, Shoufeng; Wang, Yongjin

    2014-11-01

    We present a method for distinguishing human face from high-emulation mask, which is increasingly used by criminals for activities such as stealing card numbers and passwords on ATM. Traditional facial recognition technique is difficult to detect such camouflaged criminals. In this paper, we use the high-resolution hyperspectral video capture system to detect high-emulation mask. A RGB camera is used for traditional facial recognition. A prism and a gray scale camera are used to capture spectral information of the observed face. Experiments show that mask made of silica gel has different spectral reflectance compared with the human skin. As multispectral image offers additional spectral information about physical characteristics, high-emulation mask can be easily recognized.

  10. The difficult business model for mask equipment makers and mask infrastructure development support from consortia and governments

    NASA Astrophysics Data System (ADS)

    Hector, Scott

    2005-11-01

    The extension of optical projection lithography through immersion to patterning features with half pitch <=65 nm is placing greater demands on the mask. Strong resolution enhancement techniques (RETs), such as embedded and alternating phase shift masks and complex model-based optical proximity correction, are required to compensate for diffraction and limited depth of focus (DOF). To fabricate these masks, many new or upgraded tools are required to write patterns, measure feature sizes and placement, inspect for defects, review defect printability and repair defects on these masks. Beyond the significant technical challenges, suppliers of mask fabrication equipment face the challenge of being profitable in the small market for mask equipment while encountering significant R&D expenses to bring new generations of mask fabrication equipment to market. The total available market for patterned masks is estimated to be $2.5B to $2.9B per year. The patterned mask market is about 20% of the market size for lithography equipment and materials. The total available market for mask-making equipment is estimated to be about $800M per year. The largest R&D affordability issue arises for the makers of equipment for fabricating masks where total available sales are typically less than ten units per year. SEMATECH has used discounted cash flow models to predict the affordable R&D while maintaining industry accepted internal rates of return. The results have been compared to estimates of the total R&D cost to bring a new generation of mask equipment to market for various types of tools. The analysis revealed that affordability of the required R&D is a significant problem for many suppliers of mask-making equipment. Consortia such as SEMATECH and Selete have played an important role in cost sharing selected mask equipment and material development projects. Governments in the United States, in Europe and in Japan have also helped equipment suppliers with support for R&D. This paper

  11. Redesign of an Open-System Oxygen Face Mask With Mainstream Capnometer for Children.

    PubMed

    Napolitano, Natalie; Nishisaki, Akira; Buffman, Hayley S; Leffelman, Jessica; Maltese, Matthew R; Nadkarni, Vinay M

    2017-01-01

    Partial pressure of end-tidal carbon dioxide (P ETCO 2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring P ETCO 2 in children without a tracheal tube is challenging. To improve P ETCO 2 measurement accuracy in a commercially available mask with a mainstream CO 2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup. Two sizes of redesigned face masks (small for 7-20 kg, medium for 10-40 kg) were evaluated. Initial bench testing used a simulator modeling a spontaneously breathing infant and child with a natural airway. An infant/child manikin head was connected to the breathing lung simulator. A mass flow controller provided expiratory CO 2 . Mask fit was then evaluated on healthy human subjects to identify anatomical features associated with good fit, defined as square shape capnography waveform during expiration. A 3-dimensional digital scan was used to quantify anatomical features. The gaps between face mask rims and facial surface were manually measured. Bench testing revealed a P ETCO 2 difference of 3.4 ± 1.5 mm Hg between a measured P ETCO 2 by the redesigned mask and CO 2 concentration at trachea, as compared with 6.7 ± 6.2 mm Hg between P ETCO 2 measured by nasal cannula and trachea (P < .001). In the human mask fit study, 35 children (13 ± 4 kg) with the small mask and 38 (24 ± 8 kg) with the medium mask were evaluated. Capnography tracing was successfully obtained in 86% of the small and 100% of the medium masks. In children with small-size masks, the gap between the face mask rim and the child's face was not statistically different among those with good mask fit and without (1.0 ± 1.5 mm vs 1.4 ± 1.9 mm, P = .73). P ETCO 2 measurement by a redesigned open-system face mask with a mainstream CO 2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit

  12. Optical effects of shadow masks on short circuit current of organic photovoltaic devices.

    PubMed

    Lin, Chi-Feng; Lin, Bing-Hong; Liu, Shun-Wei; Hsu, Wei-Feng; Zhang, Mi; Chiu, Tien-Lung; Wei, Mau-Kuo; Lee, Jiun-Haw

    2012-03-21

    In this paper, we have employed different shadow masks attached on top of organic photovoltaic (OPV) devices to study the optical effects of the former on the short circuit current (J(SC)). To rule out possible lateral electrical conduction and simplify the optical effects inside the device, a small-molecular heterojunction OPV device with a clear donor/acceptor interface was employed with a hole extraction layer exhibiting high resistance intentionally. Careful calibration with a shadow mask was employed. By attaching two layers of opaque masks in combination with a suitable holder design to shield the light from the edges and backside, the value of J(SC) approached that of the dark current, even under 1-sun radiation. With different illumination areas, we found that the photons illuminating the non-active region of the device contributed to 40% of the J(SC) by optical effect within the width of about 1 mm around the active region. When illuminating the non-active area with 12 mm to the active area, a 5.6 times improvement in the J(SC) was observed when the incident angle was 75°. With the introduction of a microstructured film onto the OPV device and an increase in the reflection from the non-active region, a 15% enhancement of the J(SC) compared to the control device was achieved.

  13. Inexpensive Masks for Film Deposition

    NASA Technical Reports Server (NTRS)

    Conley, W. R.

    1986-01-01

    Sputtered sprayed lines less than 2 millimeters wide made by superimposing masks with partially overlapping openings. Slits first cut in masks by stamping or other economical process. Masks superimposed so slits define new openings narrower than original slits.

  14. Mask industry assessment trend analysis

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Yun, Henry

    2009-01-01

    Microelectronics industry leaders routinely name the cost and cycle time of mask technology and mask supply as top critical issues. A survey was created with support from SEMATECH to gather information about the mask industry as an objective assessment of its overall condition. This year's survey data were presented in detail at BACUS and the detailed trend analysis presented at EMLC. The survey is designed with the input of semiconductor company mask technologists and merchant mask suppliers. This year's assessment is the seventh in the current series of annual reports. With continued industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. The results will be used to guide future investments on critical path issues. This year's survey is basically the same as the surveys in 2005 through 2007. Questions are grouped into seven categories: General Business Profile Information, Data Processing, Yields and Yield Loss, Mechanisms, Delivery Times, Returns, and Services. (Examples are given below). Within each category is a multitude of questions that creates a detailed profile of both the business and technical status of the critical mask industry.

  15. Masking Strategies for Image Manifolds.

    PubMed

    Dadkhahi, Hamid; Duarte, Marco F

    2016-07-07

    We consider the problem of selecting an optimal mask for an image manifold, i.e., choosing a subset of the pixels of the image that preserves the manifold's geometric structure present in the original data. Such masking implements a form of compressive sensing through emerging imaging sensor platforms for which the power expense grows with the number of pixels acquired. Our goal is for the manifold learned from masked images to resemble its full image counterpart as closely as possible. More precisely, we show that one can indeed accurately learn an image manifold without having to consider a large majority of the image pixels. In doing so, we consider two masking methods that preserve the local and global geometric structure of the manifold, respectively. In each case, the process of finding the optimal masking pattern can be cast as a binary integer program, which is computationally expensive but can be approximated by a fast greedy algorithm. Numerical experiments show that the relevant manifold structure is preserved through the datadependent masking process, even for modest mask sizes.

  16. Recovery from Object Substitution Masking Induced by Transient Suppression of Visual Motion Processing: A Repetitive Transcranial Magnetic Stimulation Study

    ERIC Educational Resources Information Center

    Hirose, Nobuyuki; Kihara, Ken; Mima, Tatsuya; Ueki, Yoshino; Fukuyama, Hidenao; Osaka, Naoyuki

    2007-01-01

    Object substitution masking is a form of visual backward masking in which a briefly presented target is rendered invisible by a lingering mask that is too sparse to produce lower image-level interference. Recent studies suggested the importance of an updating process in a higher object-level representation, which should rely on the processing of…

  17. Model-based MPC enables curvilinear ILT using either VSB or multi-beam mask writers

    NASA Astrophysics Data System (ADS)

    Pang, Linyong; Takatsukasa, Yutetsu; Hara, Daisuke; Pomerantsev, Michael; Su, Bo; Fujimura, Aki

    2017-07-01

    Inverse Lithography Technology (ILT) is becoming the choice for Optical Proximity Correction (OPC) of advanced technology nodes in IC design and production. Multi-beam mask writers promise significant mask writing time reduction for complex ILT style masks. Before multi-beam mask writers become the main stream working tools in mask production, VSB writers will continue to be the tool of choice to write both curvilinear ILT and Manhattanized ILT masks. To enable VSB mask writers for complex ILT style masks, model-based mask process correction (MB-MPC) is required to do the following: 1). Make reasonable corrections for complex edges for those features that exhibit relatively large deviations from both curvilinear ILT and Manhattanized ILT designs. 2). Control and manage both Edge Placement Errors (EPE) and shot count. 3. Assist in easing the migration to future multi-beam mask writer and serve as an effective backup solution during the transition. In this paper, a solution meeting all those requirements, MB-MPC with GPU acceleration, will be presented. One model calibration per process allows accurate correction regardless of the target mask writer.

  18. Resist heating effect on e-beam mask writing at 75 kV and 60 A/cm2

    NASA Astrophysics Data System (ADS)

    Benes, Zdenek; Deverich, Christina; Huang, Chester; Lawliss, Mark

    2003-12-01

    Resist heating has been known to be one of the main contributors to local CD variation in mask patterning using variable shape e-beam tools. Increasingly complex mask patterns require increased number of shapes which drives the need for higher electron beam current densities to maintain reasonable write times. As beam current density is increased, CD error resulting from resist heating may become a dominating contributor to local CD variations. In this experimental study, the IBM EL4+ mask writer with high voltage and high current density has been used to quantitatively investigate the effect of resist heating on the local CD uniformity. ZEP 7000 and several chemically amplified resists have been evaluated under various exposure conditions (single-pass, multi-pass, variable spot size) and pattern densities. Patterns were designed specifically to allow easy measurement of local CD variations with write strategies designed to maximize the effect of resist heating. Local CD variations as high as 15 nm in 18.75 × 18.75 μm sub-field size have been observed for ZEP 7000 in a single-pass writing with full 1000 nm spots at 50% pattern density. This number can be reduced by increasing the number of passes or by decreasing the maximum spot size. The local CD variation has been reduced to as low as 2 nm for ZEP 7000 for the same pattern under modified exposure conditions. The effectiveness of various writing strategies is discussed as well as their possible deficiencies. Minimal or no resist heating effects have been observed for the chemically amplified resists studied. The results suggest that the resist heating effect can be well controlled by careful selection of the resist/process system and/or writing strategy and that resist heating does not have to pose a problem for high throughput e-beam mask making that requires high voltage and high current densities.

  19. 3D printed facial laser scans for the production of localised radiotherapy treatment masks - A case study.

    PubMed

    Briggs, Matthew; Clements, Helen; Wynne, Neil; Rennie, Allan; Kellett, Darren

    This study investigates the use of 3D printing for patients that require localised radiotherapy treatment to the face. The current process involves producing a lead mask in order to protect the healthy tissue from the effects of the radiotherapy. The mask is produced by applying a thermoplastic sheet to the patient's face and allowing to set hard. This can then be used as a mould to create a plaster impression of the patient's face. A sheet of lead is then hammered on to the plaster to create a bespoke fitted face mask. This process can be distressing for patients and can be problematic when the patient is required to remain motionless for a prolonged time while the thermoplastic sets. In this study, a 1:1 scale 3D print of a patient's face was generated using a laser scanner. The lead was hammered directly on to the surface of the 3D print in order to create a bespoke fitted treatment mask. This eliminated the thermoplastic moulding stage and significantly reduced the time needed for the patient to be in clinic. The higher definition impression of the the face resulted in a more accurate, better fitting treatment mask.

  20. EUVL Mask Blank Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barty, A; Mirkarimi, P; Stearns, D G

    2002-05-22

    EUV mask blanks are fabricated by depositing a reflective Mo/Si multilayer film onto super-polished substrates. Small defects in this thin film coating can significantly alter the reflected field and introduce defects in the printed image. Ideally one would want to produce defect-free mask blanks; however, this may be very difficult to achieve in practice. One practical way to increase the yield of mask blanks is to effectively repair multilayer defects, and to this effect they present two complementary defect repair strategies for use on multilayer-coated EUVL mask blanks. A defect is any area on the mask which causes unwanted variationsmore » in EUV dose in the aerial image obtained in a printing tool, and defect repair is correspondingly defined as any strategy that renders a defect unprintable during exposure. The term defect mitigation can be adopted to describe any strategy which renders a critical defect non-critical when printed, and in this regard a non-critical defect is one that does not adversely affect device function. Defects in the patterned absorber layer consist of regions where metal, typically chrome, is unintentionally added or removed from the pattern leading to errors in the reflected field. There currently exists a mature technology based on ion beam milling and ion beam assisted deposition for repairing defects in the absorber layer of transmission lithography masks, and it is reasonable to expect that this technology will be extended to the repair of absorber defects in EUVL masks. However, techniques designed for the repair of absorber layers can not be directly applied to the repair of defects in the mask blank, and in particular the multilayer film. In this paper they present for the first time a new technique for the repair of amplitude defects as well as recent results on the repair of phase defects.« less

  1. SEMATECH EUVL mask program status

    NASA Astrophysics Data System (ADS)

    Yun, Henry; Goodwin, Frank; Huh, Sungmin; Orvek, Kevin; Cha, Brian; Rastegar, Abbas; Kearney, Patrick

    2009-04-01

    As we approach the 22nm half-pitch (hp) technology node, the industry is rapidly running out of patterning options. Of the several lithography techniques highlighted in the International Technology Roadmap for Semiconductors (ITRS), the leading contender for the 22nm hp insertion is extreme ultraviolet lithography (EUVL). Despite recent advances with EUV resist and improvements in source power, achieving defect free EUV mask blank and enabling the EUV mask infrastructure still remain critical issues. To meet the desired EUV high volume manufacturing (HVM) insertion target date of 2013, these obstacles must be resolved on a timely bases. Many of the EUV mask related challenges remain in the pre-competitive stage and a collaborative industry based consortia, such as SEMATECH can play an important role to enable the EUVL landscape. SEMATECH based in Albany, NY is an international consortium representing several of the largest manufacturers in the semiconductor market. Full members include Intel, Samsung, AMD, IBM, Panasonic, HP, TI, UMC, CNSE (College of Nanoscience and Engineering), and Fuller Road Management. Within the SEMATECH lithography division a major thrust is centered on enabling the EUVL ecosystem from mask development, EUV resist development and addressing EUV manufacturability concerns. An important area of focus for the SEMATECH mask program has been the Mask Blank Development Center (MBDC). At the MBDC key issues in EUV blank development such as defect reduction and inspection capabilities are actively pursued together with research partners, key suppliers and member companies. In addition the mask program continues a successful track record of working with the mask community to manage and fund critical mask tools programs. This paper will highlight recent status of mask projects and longer term strategic direction at the MBDC. It is important that mask technology be ready to support pilot line development HVM by 2013. In several areas progress has been

  2. Exoplanet Coronagraph Shaped Pupil Masks and Laboratory Scale Star Shade Masks: Design, Fabrication and Characterization

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatha; White, Victor; Yee, Karl; Echternach, Pierre; Muller, Richard; Dickie, Matthew; Cady, Eric; Mejia Prada, Camilo; Ryan, Daniel; Poberezhskiy, Ilya; hide

    2015-01-01

    Star light suppression technologies to find and characterize faint exoplanets include internal coronagraph instruments as well as external star shade occulters. Currently, the NASA WFIRST-AFTA mission study includes an internal coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host star light to about 10 -9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, achromaticity, etc. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed (HCIT) at JPL and from the High Contrast Imaging Lab (HCIL) at Princeton University. We also present briefly the technologies applied to fabricate laboratory scale star shade masks.

  3. Exoplanet coronagraph shaped pupil masks and laboratory scale star shade masks: design, fabrication and characterization

    NASA Astrophysics Data System (ADS)

    Balasubramanian, Kunjithapatham; White, Victor; Yee, Karl; Echternach, Pierre; Muller, Richard; Dickie, Matthew; Cady, Eric; Mejia Prada, Camilo; Ryan, Daniel; Poberezhskiy, Ilya; Zhou, Hanying; Kern, Brian; Riggs, A. J.; Zimmerman, Neil T.; Sirbu, Dan; Shaklan, Stuart; Kasdin, Jeremy

    2015-09-01

    Star light suppression technologies to find and characterize faint exoplanets include internal coronagraph instruments as well as external star shade occulters. Currently, the NASA WFIRST-AFTA mission study includes an internal coronagraph instrument to find and characterize exoplanets. Various types of masks could be employed to suppress the host star light to about 10-9 level contrast over a broad spectrum to enable the coronagraph mission objectives. Such masks for high contrast internal coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, achromaticity, etc. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks by combining electron beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each, highlighting milestone accomplishments from the High Contrast Imaging Testbed (HCIT) at JPL and from the High Contrast Imaging Lab (HCIL) at Princeton University. We also present briefly the technologies applied to fabricate laboratory scale star shade masks.

  4. [Oxygenation: the impact of face mask coupling.].

    PubMed

    Gregori, Waldemar Montoya de; Mathias, Lígia Andrade da Silva Telles; Piccinini Filho, Luiz; Pena, Ernesto Leonardo de Carpio; Vicuna, Aníbal Heberto Mora; Vieira, Joaquim Edson

    2005-10-01

    Different oxygenation techniques aim at promoting denitrogenation before apnea during induction. The main reason why CIO2 = 100% cannot be reached is the lack of adequate face mask coupling, allowing the entry of room air. Although anesthesiologists know this principle, not all of them apply it correctly, facilitating the entry of air in fresh gases flow and consequently diluting CIO2. This prospective study was performed to comparatively evaluate, through the variation of oxygen expired concentration (CEO2), the efficacy of the oxygenation technique via face mask in the conditions routinely used by anesthesiologists, simulating situations of progressive leaks. Oxygen end-tidal concentrations of 15 volunteers, physical status ASA I, were studied with 8 deep breaths (vital capacity) in 60 s with fresh gas flow of 10 L.min-1. The face mask was: tightly fitted with 100% CIO2 (Tf100) or varying from 50% to 90%, (Tf50, Tf60, Tf70, Tf80, Tf90); gravity-coupled to face and 100% CIO2 (Grav) and moved 1 cm away from face with 100% CIO2 (Aw). CEO2 was recorded at 10 s intervals. P < 0.05 was considered statistically significant. CEO2 has increased for all groups (p < 0.001), but only Tf100 reached values close to ideal (82.20 - 87). Comparing mean CEO2 of Grav and Tf100 at the end of 60s, (82.20 and 65.87) there was a difference of approximately 20% between both techniques, since gravity-coupled mask only did not provide adequate oxygenation. There were no significant differences between groups Tf70 and Grav (65.87 and 62.67) in all studied moments, suggesting that the latter simulates a 70% CIO2 at 60 s. Mean Aw group CEO2 increased to 47.20 at 60s showing that this technique may be associated to unacceptable risk of hypoxemia. All situations of face mask coupling gradually increased CEO2, although with decreased oxygenation efficacy due to situations of face mask malposition. This study has shown the need for attention during oxygenation, using well coupled face mask and

  5. Results of a Multicenter, Randomized, Double-Masked, Placebo-Controlled Clinical Study of the Efficacy and Safety of Visomitin Eye Drops in Patients with Dry Eye Syndrome.

    PubMed

    Brzheskiy, Vladimir V; Efimova, Elena L; Vorontsova, Tatiana N; Alekseev, Vladimir N; Gusarevich, Olga G; Shaidurova, Ksenia N; Ryabtseva, Alla A; Andryukhina, Olga M; Kamenskikh, Tatiana G; Sumarokova, Elena S; Miljudin, Eugeny S; Egorov, Eugeny A; Lebedev, Oleg I; Surov, Alexander V; Korol, Andrii R; Nasinnyk, Illia O; Bezditko, Pavel A; Muzhychuk, Olena P; Vygodin, Vladimir A; Yani, Elena V; Savchenko, Alla Y; Karger, Elena M; Fedorkin, Oleg N; Mironov, Alexander N; Ostapenko, Victoria; Popeko, Natalia A; Skulachev, Vladimir P; Skulachev, Maxim V

    2015-12-01

    This article presents the results of an international, multicenter, randomized, double-masked, placebo-controlled clinical study of Visomitin (Mitotech LLC, Moscow, Russian Federation) eye drops in patients with dry eye syndrome (DES). Visomitin is the first registered (in Russia) drug with a mitochondria-targeted antioxidant (SkQ1) as the active ingredient. In this multicenter (10 sites) study of 240 subjects with DES, study drug (Visomitin or placebo) was self-administered three times daily (TID) for 6 weeks, followed by a 6-week follow-up period. Seven in-office study visits occurred every 2 weeks during both the treatment and follow-up periods. Efficacy measures included Schirmer's test, tear break-up time, fluorescein staining, meniscus height, and visual acuity. Safety measures included adverse events, slit lamp biomicroscopy, tonometry, blood pressure, and heart rate. Tolerability was also evaluated. This clinical study showed the effectiveness of Visomitin eye drops in the treatment of signs and symptoms of DES compared with placebo. The study showed that a 6-week course of TID topical instillation of Visomitin significantly improved the functional state of the cornea; Visomitin increased tear film stability and reduced corneal damage. Significant reduction of dry eye symptoms (such as dryness, burning, grittiness, and blurred vision) was also observed. Based on the results of this study, Visomitin is effective and safe for use in eye patients with DES for protection from corneal damage. Mitotech LLC.

  6. Critical ratios of beluga whales (Delphinapterus leucas) and masked signal duration.

    PubMed

    Erbe, Christine

    2008-10-01

    This article examines the masking of a complex beluga vocalization by natural and anthropogenic noise. The call consisted of six 150 ms pulses exhibiting spectral peaks between 800 Hz and 8 kHz. Comparing the spectra and spectrograms of the call and noises at detection threshold showed that the animal did not hear the entire call at threshold. It only heard parts of the call in frequency and time. From the masked hearing thresholds in broadband continuous noises, critical ratios were computed. Fletcher critical bands were narrower than either 15 or 111 of an octave at the low frequencies of the call (<2 kHz), depending on which frequency the animal cued on. From the masked hearing thresholds in intermittent noises, the audible signal duration at detection threshold was computed. The intermittent noises differed in gap length, gap number, and masking, but the total audible signal duration at threshold was the same: 660 ms. This observation supports a multiple-looks model. The two amplitude modulated noises exhibited weaker masking than the unmodulated noises hinting at a comodulation masking release.

  7. Non-invasive ventilation: evaluation of CO2 washout by intentional leaking in three recent oronasal masks. A pilot study.

    PubMed

    Medrinal, C; Prieur, G; Contal, O; Villiot-Danger, E; Doyle, C; Reychler, G; Quieffin, J

    2015-05-01

    Many types of interfaces with intentional leaks exist for Non Invasive Ventilation. The purpose of intentional leaks is to remove CO2 from the interface, however the calibration does not allow a sufficiently large flow and rebreathing of CO2 can occur. The aim of this study was to compare the CO2 rinsing capacities of three new generation oronasal masks with intentional leaks (A: Quattro®, [Resmed]; B: Amara® [Respironics]; C: Forma® [Fisher&Paykel]) in healthy subjects. Seventeen healthy volunteers were included in this prospective cross-sectional, randomized, double-blinded trial. Each subject underwent ventilation with a home ventilator (IPAP: 14 cmH2O; EPAP: 4 cmH2O) with each mask consecutively. Transcutaneous capnography (PtcCO2) recordings were carried out throughout the trial and ventilator data (tidal volume, respiratory rate, minute ventilation and unintentional leaks) were also analyzed. Mask comfort was assessed using a visual analog scale (0 to 10). The results showed no differences in PtcCO2 between masks (P=0.82). There were no significant differences in respiratory parameters (tidal volume, P=0.79; respiratory rate, P=0.65; minute ventilation, P=0.12) between masks. The rate of unintentional leaks were significantly lower for Mask A (P=0.016). Subjects rated Mask A and Mask C as more comfortable than Mask B (P=0.041). There was no effect of mask on PtcCO2 in healthy subjects. The mask with the highest comfort rating had not the lowest rate of unintentional leaks.

  8. The extended functional neuroanatomy of emotional processing biases for masked faces in major depressive disorder.

    PubMed

    Victor, Teresa A; Furey, Maura L; Fromm, Stephen J; Bellgowan, Patrick S F; Öhman, Arne; Drevets, Wayne C

    2012-01-01

    Major depressive disorder (MDD) is associated with a mood-congruent processing bias in the amygdala toward face stimuli portraying sad expressions that is evident even when such stimuli are presented below the level of conscious awareness. The extended functional anatomical network that maintains this response bias has not been established, however. To identify neural network differences in the hemodynamic response to implicitly presented facial expressions between depressed and healthy control participants. Unmedicated-depressed participants with MDD (n=22) and healthy controls (HC; n=25) underwent functional MRI as they viewed face stimuli showing sad, happy or neutral face expressions, presented using a backward masking design. The blood-oxygen-level dependent (BOLD) signal was measured to identify regions where the hemodynamic response to the emotionally valenced stimuli differed between groups. The MDD subjects showed greater BOLD responses than the controls to masked-sad versus masked-happy faces in the hippocampus, amygdala and anterior inferotemporal cortex. While viewing both masked-sad and masked-happy faces relative to masked-neutral faces, the depressed subjects showed greater hemodynamic responses than the controls in a network that included the medial and orbital prefrontal cortices and anterior temporal cortex. Depressed and healthy participants showed distinct hemodynamic responses to masked-sad and masked-happy faces in neural circuits known to support the processing of emotionally valenced stimuli and to integrate the sensory and visceromotor aspects of emotional behavior. Altered function within these networks in MDD may establish and maintain illness-associated differences in the salience of sensory/social stimuli, such that attention is biased toward negative and away from positive stimuli.

  9. Mask pattern generator employing EPL technology

    NASA Astrophysics Data System (ADS)

    Yoshioka, Nobuyuki; Yamabe, Masaki; Wakamiya, Wataru; Endo, Nobuhiro

    2003-08-01

    Mask cost is one of crucial issues in device fabrication, especially in SoC (System on a Chip) with small-volume production. The cost mainly depends on productivity of mask manufacturing tools such as mask writers and defect inspection tools. EPL (Electron Projection Lithography) has been developing as a high-throughput electron beam exposure technology that will succeed optical lithography. The application of EPL technology to mask writing will result in high productivity and contribute to decrease the mask cost. The concept of a mask pattern generator employing EPL technology is proposed in this paper. It is very similar to EPL technology used for pattern printing on a wafer. The mask patterns on the glass substrate are exposed by projecting the basic circuit patterns formed on the mother EPL mask. One example of the mother EPL mask is a stencil type made with 200-mm Si wafer. The basic circuit patterns are IP patterns and logical primitive patterns such as cell libraries (AND, OR, Inverter, Flip-Flop and etc.) to express the SoC device patterns. Since the SoC patterns are exposed with its collective units such as IP and logical primitive patterns by using this method, the high throughput will be expected comparing with conventional mask E-beam writers. In this paper, the mask pattern generator with the EPL technology is proposed. The concept, its advantages and issues to be solved are discussed.

  10. Psychometric functions for informational masking

    NASA Astrophysics Data System (ADS)

    Lutfi, Robert A.; Kistler, Doris J.; Callahan, Michael R.; Wightman, Frederic L.

    2003-04-01

    The method of constant stimuli was used to obtain complete psychometric functions (PFs) from 44 normal-hearing listeners in conditions known to produce varying amounts of informational masking. The task was to detect a pure-tone signal in the presence of a broadband noise and in the presence of multitone maskers with frequencies and amplitudes that varied at random from one presentation to the next. Relative to the broadband noise condition, significant reductions were observed in both the slope and the upper asymptote of the PF for multitone maskers producing large amounts of informational masking. Slope was affected more for some listeners while asymptote was affected more for others. Mean slopes and asymptotes varied nonmonotonically with the number of masker components in much the same manner as mean thresholds. The results are consistent with a model that assumes trial-by-trial judgments are based on a weighted sum of dB levels at the output of independent auditory filters. For many listeners, however, the weights appear to reflect how often a nonsignal auditory filter is mistaken for the signal filter. For these listeners adaptive procedures may produce a significant bias in the estimates of threshold for conditions of informational masking. [Work supported by NIDCD.

  11. Clinical efficacy and safety of a light mask for prevention of dark adaptation in treating and preventing progression of early diabetic macular oedema at 24 months (CLEOPATRA): a multicentre, phase 3, randomised controlled trial.

    PubMed

    Sivaprasad, Sobha; Vasconcelos, Joana C; Prevost, A Toby; Holmes, Helen; Hykin, Philip; George, Sheena; Murphy, Caroline; Kelly, Joanna; Arden, Geoffrey B

    2018-05-01

    We aimed to assess 24-month outcomes of wearing an organic light-emitting sleep mask as an intervention to treat and prevent progression of non-central diabetic macular oedema. CLEOPATRA was a phase 3, single-blind, parallel-group, randomised controlled trial undertaken at 15 ophthalmic centres in the UK. Adults with non-centre-involving diabetic macular oedema were randomly assigned (1:1) to wearing either a light mask during sleep (Noctura 400 Sleep Mask, PolyPhotonix Medical, Sedgefield, UK) or a sham (non-light) mask, for 24 months. Randomisation was by minimisation generated by a central web-based computer system. Outcome assessors were masked technicians and optometrists. The primary outcome was the change in maximum retinal thickness on optical coherence tomography (OCT) at 24 months, analysed using a linear mixed-effects model incorporating 4-monthly measurements and baseline adjustment. Analysis was done using the intention-to-treat principle in all randomised patients with OCT data. Safety was assessed in all patients. This trial is registered with Controlled-Trials.com, number ISRCTN85596558. Between April 10, 2014, and June 15, 2015, 308 patients were randomly assigned to wearing the light mask (n=155) or a sham mask (n=153). 277 patients (144 assigned the light mask and 133 the sham mask) contributed to the mixed-effects model over time, including 246 patients with OCT data at 24 months. The change in maximum retinal thickness at 24 months did not differ between treatment groups (mean change -9·2 μm [SE 2·5] for the light mask vs -12·9 μm [SE 2·9] for the sham mask; adjusted mean difference -0·65 μm, 95% CI -6·90 to 5·59; p=0·84). Median compliance with wearing the light mask at 24 months was 19·5% (IQR 1·9-51·6). No serious adverse events were related to either mask. The most frequent adverse events related to the assigned treatment were discomfort on the eyes (14 with the light mask vs seven with the sham mask), painful, sticky, or

  12. LMA Supreme for neonatal resuscitation: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background The most important action in the resuscitation of a newborn in the delivery room is to establish effective assisted ventilation. The face mask and endotracheal tube are the devices used to achieve this goal. Laryngeal mask airways that fit over the laryngeal inlet have been shown to be effective for ventilating newborns at birth and should be considered as an alternative to facemask ventilation or endotracheal intubation among newborns weighing >2,000 g or delivered ≥34 weeks’ gestation. A recent systematic review and meta-analysis of supraglottic airways in neonatal resuscitation reported the results of four randomized controlled trials (RCTs) stating that fewer infants in the group using laryngeal mask airways required endotracheal intubation (1.5%) compared to the group using face masks (12.0%). However, there were methodological concerns over all the RCTs including the fact that the majority of the operators in the trials were anesthesiologists. Our hypothesis is based on the assumption that ventilating newborns needing positive pressure ventilation with a laryngeal mask airway will be more effective than ventilating with a face mask in a setting where neonatal resuscitation is performed by midwives, nurses, and pediatricians. The primary aim of this study will be to assess the effectiveness of the laryngeal mask airway over the face mask in preventing the need for endotracheal intubation. Methods/design This will be an open, prospective, randomized, single center, clinical trial. In this study, 142 newborns weighing >1,500 g or delivered ≥34 weeks gestation needing positive pressure ventilation at birth will be randomized to be ventilated with a laryngeal mask airway (LMA SupremeTM, LMA Company, UK - intervention group) or with a face mask (control group). Primary outcome: Proportion of newborns needing endotracheal intubation. Secondary outcomes: Apgar score at 5 minutes, time to first breath, onset of the first cry, duration of

  13. Visual Masking During Pursuit Eye Movements

    ERIC Educational Resources Information Center

    White, Charles W.

    1976-01-01

    Visual masking occurs when one stimulus interferes with the perception of another stimulus. Investigates which matters more for visual masking--that the target and masking stimuli are flashed on the same part of the retina, or, that the target and mask appear in the same place. (Author/RK)

  14. [Patients' reaction to pharmacists wearing a mask during their consultations].

    PubMed

    Tamura, Eri; Kishimoto, Keiko; Fukushima, Noriko

    2013-01-01

      This study sought to determine the effect of pharmacists wearing a mask on the consultation intention of patients who do not have a trusting relationship with the pharmacists. We conducted a questionnaire survey of customers at a Tokyo drugstore in August 2012. Subjects answered a questionnaire after watching two medical teaching videos, one in which the pharmacist was wearing a mask and the other in which the pharmacist was not wearing a mask. Data analysis was performed using a paired t-test and multiple logistic regression. The paired t-test revealed a significant difference in 'Maintenance Problem' between the two pharmacist situations. After excluding factors not associated with wearing a mask, multiple logistic regression analysis identified three independent variables with a significant effect on participants not wanting to consult with a pharmacist wearing a mask. Positive factors were 'active-inactive' and 'frequency mask use', a negative factor was 'age'. Our study has shown that pharmacists wearing a mask may be a factor that prevents patients from consulting with pharmacist. Those patients whose intention to consult might be affected by the pharmacists wearing a mask tended to be younger, to have no habit of wearing masks preventively themselves, and to form a negative opinion of such pharmacists. Therefore, it was estimated that pharmacists who wear masks need to provide medical education by asking questions more positively than when they do not wear a mask in order to prevent the patient worrying about oneself.

  15. Monaural informational masking release in children and adults

    NASA Astrophysics Data System (ADS)

    Buss, Emily; Hall, Joseph W.; Grose, John H.

    2004-05-01

    Informational masking refers to an elevation in signal threshold due to stimulus uncertainty, rather than to energetic masking. This study assessed informational masking and utilization of cues to reduce that masking in children aged 5-9 and adults. We used a manipulation introduced by Kidd et al. [J. Acoust. Soc. Am. 95, 3475-3480 (1994)] in which the signal was a train of eight consecutive tone bursts, each at 1 kHz and 60 ms in duration. Maskers were comprised of a pair of synchronous tone-burst trains whose frequencies were selected from the range spanning 0.2-5 kHz, with a protected region 851-1175 Hz. In the reference condition, where informational masking is pronounced, these maskers were eight bursts and had a fixed frequency within each interval, with new frequencies chosen randomly prior to each interval. Two conditions of masking release were tested: random frequency selection for each masker burst and a masker leading fringe of two additional 60-ms bursts. Both children and adults showed a significant informational masking effect, with children showing a larger effect. Both groups also showed significant release from masking, though initial results suggest that this may have been reduced in the youngest children. [Work supported by NIH, RO1 DC00397.

  16. A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study

    PubMed Central

    Zhou, YingHai; Jew, Korinne

    2016-01-01

    Laryngeal masks are invasive devices for airway management placed in the supraglottic position. The Shiley™ laryngeal mask (Shiley™ LM) features an integrated inflation tube and airway shaft to facilitate product insertion and reduce the chance of tube occlusion when patients bite down. This study compared the Shiley LM to two other disposable laryngeal mask devices, the Ambu® AuraStraight™ and the LMA Unique™. Overall device design, tensile strength, flexibility of various structures, and sealing performance were measured. The Shiley LM is structurally stronger and its shaft is more resistant to compression than the other devices. The Shiley LM is generally less flexible than the other devices, but this relationship varies with device size. Sealing performance of the devices was similar in a bench assay. The results of this bench study demonstrate that the new Shiley LM resembles other commercially available laryngeal mask devices, though it exhibits greater tensile strength and lower flexibility. PMID:27843359

  17. A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study.

    PubMed

    Zhou, YingHai; Jew, Korinne

    2016-01-01

    Laryngeal masks are invasive devices for airway management placed in the supraglottic position. The Shiley™ laryngeal mask (Shiley™ LM) features an integrated inflation tube and airway shaft to facilitate product insertion and reduce the chance of tube occlusion when patients bite down. This study compared the Shiley LM to two other disposable laryngeal mask devices, the Ambu ® AuraStraight™ and the LMA Unique™. Overall device design, tensile strength, flexibility of various structures, and sealing performance were measured. The Shiley LM is structurally stronger and its shaft is more resistant to compression than the other devices. The Shiley LM is generally less flexible than the other devices, but this relationship varies with device size. Sealing performance of the devices was similar in a bench assay. The results of this bench study demonstrate that the new Shiley LM resembles other commercially available laryngeal mask devices, though it exhibits greater tensile strength and lower flexibility.

  18. Collinear masking effect in visual search is independent of perceptual salience.

    PubMed

    Jingling, Li; Lu, Yi-Hui; Cheng, Miao; Tseng, Chia-Huei

    2017-07-01

    Searching for a target in a salient region should be easier than looking for one in a nonsalient region. However, we previously discovered a contradictory phenomenon in which a local target in a salient structure was more difficult to find than one in the background. The salient structure was constructed of orientation singletons aligned to each other to form a collinear structure. In the present study, we undertake to determine whether such a masking effect was a result of salience competition between a global structure and the local target. In the first 3 experiments, we increased the salience value of the local target with the hope of adding to its competitive advantage and eventually eliminating the masking effect; nevertheless, the masking effect persisted. In an additional 2 experiments, we reduced salience of the global collinear structure by altering the orientation of the background bars and the masking effect still emerged. Our salience manipulations were validated by a controlled condition in which the global structure was grouped noncollinearly. In this case, local target salience increase (e.g., onset) or global distractor salience reduction (e.g., randomized flanking orientations) effectively removed the facilitation effect of the noncollinear structure. Our data suggest that salience competition is unlikely to explain the collinear masking effect, and other mechanisms such as contour integration, border formation, or the crowding effect may be prospective candidates for further investigation.

  19. An orbital angular momentum radio communication system optimized by intensity controlled masks effectively: Theoretical design and experimental verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Xinlu; Applied Optics Beijing Area Major Laboratory, Department of Physics, Beijing Normal University, Beijing 100875; Huang, Shanguo, E-mail: shghuang@bupt.edu.cn

    A system of generating and receiving orbital angular momentum (OAM) radio beams, which are collectively formed by two circular array antennas (CAAs) and effectively optimized by two intensity controlled masks, is proposed and experimentally investigated. The scheme is effective in blocking of the unwanted OAM modes and enhancing the power of received radio signals, which results in the capacity gain of system and extended transmission distance of the OAM radio beams. The operation principle of the intensity controlled masks, which can be regarded as both collimator and filter, is feasible and simple to realize. Numerical simulations of intensity and phasemore » distributions at each key cross-sectional plane of the radio beams demonstrate the collimated results. The experimental results match well with the theoretical analysis and the receive distance of the OAM radio beam at radio frequency (RF) 20 GHz is extended up to 200 times of the wavelength of the RF signals, the measured distance is 5 times of the original measured distance. The presented proof-of-concept experiment demonstrates the feasibility of the system.« less

  20. Efficacy of a heat exchanger mask in cold exercise-induced asthma.

    PubMed

    Beuther, David A; Martin, Richard J

    2006-05-01

    To determine the efficacy of a novel mask device in limiting cold air exercise-induced decline in lung function in subjects with a history of exercise-induced asthma (EIA). In spite of appropriate medical therapy, many asthma patients are limited in cold weather activities. In study 1, 13 asthmatic subjects performed two randomized, single-blind treadmill exercise tests while breathing cold air (- 25 to - 15 degrees C) through a placebo or active heat exchanger mask. In study 2, five subjects with EIA performed three treadmill exercise tests while breathing cold air: one test using the heat exchanger mask, one test without the mask but with albuterol pretreatment, and one test with neither the mask nor albuterol pretreatment (unprotected exercise). For all studies, spirometry was performed before and at 5, 15, and 30 min after exercise challenge. For both studies, a total of 15 subjects with a history of asthma symptoms during cold air exercise were recruited. In study 1, the mean decrease (+/- SE) in FEV1 was 19 +/- 4.9% with placebo, and 4.3 +/- 1.6% with the active device (p = 0.0002). The mean decrease in maximum mid-expiratory flow (FEF(25-75)) was 31 +/- 5.7% with placebo and 4.7 +/- 1.7% with the active device (p = 0.0002). In study 2, the mean decrease in FEV1 was 6.3 +/- 3.9%, 11 +/- 3.7%, and 28 +/- 10% for the heat exchanger mask, albuterol pretreatment, and unprotected exercises, respectively (p = 0.4375 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). The mean decrease in FEF(25-75) was 10 +/- 4.8%, 23 +/- 6.0%, and 36 +/- 11%, respectively (p = 0.0625 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). This heat exchanger mask blocks cold exercise-induced decline in lung function at least as effectively as albuterol pretreatment.

  1. Predicting out-of-office blood pressure level using repeated measurements in the clinic: an observational cohort study

    PubMed Central

    Sheppard, James P.; Holder, Roger; Nichols, Linda; Bray, Emma; Hobbs, F.D. Richard; Mant, Jonathan; Little, Paul; Williams, Bryan; Greenfield, Sheila; McManus, Richard J.

    2014-01-01

    Objectives: Identification of people with lower (white-coat effect) or higher (masked effect) blood pressure at home compared to the clinic usually requires ambulatory or home monitoring. This study assessed whether changes in SBP with repeated measurement at a single clinic predict subsequent differences between clinic and home measurements. Methods: This study used an observational cohort design and included 220 individuals aged 35–84 years, receiving treatment for hypertension, but whose SBP was not controlled. The characteristics of change in SBP over six clinic readings were defined as the SBP drop, the slope and the quadratic coefficient using polynomial regression modelling. The predictive abilities of these characteristics for lower or higher home SBP readings were investigated with logistic regression and repeated operating characteristic analysis. Results: The single clinic SBP drop was predictive of the white-coat effect with a sensitivity of 90%, specificity of 50%, positive predictive value of 56% and negative predictive value of 88%. Predictive values for the masked effect and those of the slope and quadratic coefficient were slightly lower, but when the slope and quadratic variables were combined, the sensitivity, specificity, positive and negative predictive values for the masked effect were improved to 91, 48, 24 and 97%, respectively. Conclusion: Characteristics obtainable from multiple SBP measurements in a single clinic in patients with treated hypertension appear to reasonably predict those unlikely to have a large white-coat or masked effect, potentially allowing better targeting of out-of-office monitoring in routine clinical practice. PMID:25144295

  2. Layperson mouth-to-mask ventilation using a modified I-gel laryngeal mask after brief onsite instruction: a manikin-based feasibility trial.

    PubMed

    Schälte, Gereon; Bomhard, Lilli-Theresa; Rossaint, Rolf; Coburn, Mark; Stoppe, Christian; Zoremba, Norbert; Rieg, Annette

    2016-05-12

    The intention of this manikin-based trial was to evaluate whether laypersons are able to operate an I-gel laryngeal mask (I-gel) modified for mouth-to-mask ventilation after receiving brief on-site instruction. Entrance hall of a university hospital and the city campus of a public technical university, using a protected manikin scenario. Laypersons were handed a labelled, mouthpiece-integrated I-gel laryngeal mask and a corresponding instruction chart and were asked to follow the printed instructions. The overall process was analysed and evaluated according to quality and duration. Data from 100 participants were analysed. Overall, 79% of participants were able to effectively ventilate the manikin, 90% placed the laryngeal mask with the correct turn and direction, 19% did not position the mask deep enough and 85% believed that their inhibition threshold for performing resuscitation was lowered. A significant reduction in reluctance before and after the trial was found (p<0.0001). A total of 35% of participants had concerns about applying first aid in an emergency. Former basic life support (BLS) training significantly reduced the time of insertion (19.6 s, 95% CI 17.8 to 21.5, p=0.0004) and increased overall success (p=0.0096). Laypersons were able to manage mouth-to-mask ventilation in the manikin with a reasonable success rate after receiving brief chart-based on-site instructions using a labelled I-gel mask. Positioning the mask deep enough and identifying whether the manikin was successfully ventilated were the main problems observed. A significant reduction in reluctance towards initialising BLS by using a modified supraglottic airway device (SAD) may lead to better acceptance of bystander resuscitation in laypersons, supporting the introduction of SADs into BLS courses and the stocking of SADs in units with public automatic external defibrillators. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  3. Direct Mask Overlay Inspection

    NASA Astrophysics Data System (ADS)

    Hsia, Liang-Choo; Su, Lo-Soun

    1983-11-01

    In this paper, we present a mask inspection methodology and procedure that involves direct X-Y measurements. A group of dice is selected for overlay measurement; four measurement targets were laid out in the kerf of each die. The measured coordinates are then fit-ted to either a "historical" grid, which reflects the individual tool bias, or to an ideal grid squares fashion. Measurements are done using a Nikon X-Y laser interferometric measurement system, which provides a reference grid. The stability of the measurement system is essential. We then apply appropriate statistics to the residual after the fit to determine the overlay performance. Statistical methods play an important role in the product disposition. The acceptance criterion is, however, a compromise between the cost for mask making and the final device yield. In order to satisfy the demand on mask houses for quality of masks and high volume, mixing lithographic tools in mask making has become more popular, in particular, mixing optical and E-beam tools. In this paper, we also discuss the inspection procedure for mixing different lithographic tools.

  4. Phase 2 Randomized, Double-Masked, Vehicle-Controlled Trial of Recombinant Human Nerve Growth Factor for Neurotrophic Keratitis.

    PubMed

    Bonini, Stefano; Lambiase, Alessandro; Rama, Paolo; Sinigaglia, Francesco; Allegretti, Marcello; Chao, Wendy; Mantelli, Flavio

    2018-04-10

    To evaluate the safety and efficacy of topical recombinant human nerve growth factor (rhNGF) for treating moderate-to-severe neurotrophic keratitis (NK), a rare degenerative corneal disease resulting from impaired corneal innervation. Phase 2 multicenter, randomized, double-masked, vehicle-controlled trial. Patients with stage 2 (moderate) or stage 3 (severe) NK in 1 eye. The REPARO phase 2 study assessed safety and efficacy in 156 patients randomized 1:1:1 to rhNGF 10 μg/ml, 20 μg/ml, or vehicle. Treatment was administered 6 drops per day for 8 weeks. Patients then entered a 48- or 56-week follow-up period. Safety was assessed in all patients who received study treatment, whereas efficacy was by intention to treat. Corneal healing (defined as <0.5-mm maximum diameter of fluorescein staining in the lesion area) was assessed by masked central readers at week 4 (primary efficacy end point) and week 8 (key secondary end point) of controlled treatment. Corneal healing was reassessed post hoc by masked central readers using a more conservative measure (0-mm staining in the lesion area and no other persistent staining). At week 4 (primary end point), 19.6% of vehicle-treated patients achieved corneal healing (<0.5-mm lesion staining) versus 54.9% receiving rhNGF 10 μg/ml (+35.3%; 97.06% confidence interval [CI], 15.88-54.71; P < 0.001) and 58.0% receiving rhNGF 20 μg/ml (+38.4%; 97.06% CI, 18.96-57.83; P < 0.001). At week 8 (key secondary end point), 43.1% of vehicle-treated patients achieved less than 0.5-mm lesion staining versus 74.5% receiving rhNGF 10 μg/ml (+31.4%; 97.06% CI, 11.25-51.49; P = 0.001) and 74.0% receiving rhNGF 20 μg/ml (+30.9%; 97.06% CI, 10.60-51.13; P = 0.002). Post hoc analysis of corneal healing by the more conservative measure (0-mm lesion staining and no other persistent staining) maintained statistically significant differences between rhNGF and vehicle at weeks 4 and 8. More than 96% of patients who healed after controlled rh

  5. Communication masking in marine mammals: A review and research strategy.

    PubMed

    Erbe, Christine; Reichmuth, Colleen; Cunningham, Kane; Lucke, Klaus; Dooling, Robert

    2016-02-15

    Underwater noise, whether of natural or anthropogenic origin, has the ability to interfere with the way in which marine mammals receive acoustic signals (i.e., for communication, social interaction, foraging, navigation, etc.). This phenomenon, termed auditory masking, has been well studied in humans and terrestrial vertebrates (in particular birds), but less so in marine mammals. Anthropogenic underwater noise seems to be increasing in parts of the world's oceans and concerns about associated bioacoustic effects, including masking, are growing. In this article, we review our understanding of masking in marine mammals, summarise data on marine mammal hearing as they relate to masking (including audiograms, critical ratios, critical bandwidths, and auditory integration times), discuss masking release processes of receivers (including comodulation masking release and spatial release from masking) and anti-masking strategies of signalers (e.g. Lombard effect), and set a research framework for improved assessment of potential masking in marine mammals. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Coded mask telescopes for X-ray astronomy

    NASA Astrophysics Data System (ADS)

    Skinner, G. K.; Ponman, T. J.

    1987-04-01

    The principle of the coded mask techniques are discussed together with the methods of image reconstruction. The coded mask telescopes built at the University of Birmingham, including the SL 1501 coded mask X-ray telescope flown on the Skylark rocket and the Coded Mask Imaging Spectrometer (COMIS) projected for the Soviet space station Mir, are described. A diagram of a coded mask telescope and some designs for coded masks are included.

  7. Central masking with bilateral cochlear implants

    PubMed Central

    Lin, Payton; Lu, Thomas; Zeng, Fan-Gang

    2013-01-01

    Across bilateral cochlear implants, contralateral threshold shift has been investigated as a function of electrode difference between the masking and probe electrodes. For contralateral electric masking, maximum threshold elevations occurred when the position of the masker and probe electrode was approximately place-matched across ears. The amount of masking diminished with increasing masker-probe electrode separation. Place-dependent masking occurred in both sequentially implanted ears, and was not affected by the masker intensity or the time delay from the masker onset. When compared to previous contralateral masking results in normal hearing, the similarities between place-dependent central masking patterns suggest comparable mechanisms of overlapping excitation in the central auditory nervous system. PMID:23363113

  8. Task-Dependent Masked Priming Effects in Visual Word Recognition

    PubMed Central

    Kinoshita, Sachiko; Norris, Dennis

    2012-01-01

    A method used widely to study the first 250 ms of visual word recognition is masked priming: These studies have yielded a rich set of data concerning the processes involved in recognizing letters and words. In these studies, there is an implicit assumption that the early processes in word recognition tapped by masked priming are automatic, and masked priming effects should therefore be invariant across tasks. Contrary to this assumption, masked priming effects are modulated by the task goal: For example, only word targets show priming in the lexical decision task, but both words and non-words do in the same-different task; semantic priming effects are generally weak in the lexical decision task but are robust in the semantic categorization task. We explain how such task dependence arises within the Bayesian Reader account of masked priming (Norris and Kinoshita, 2008), and how the task dissociations can be used to understand the early processes in lexical access. PMID:22675316

  9. Compliance with the Use of Medical and Cloth Masks Among Healthcare Workers in Vietnam.

    PubMed

    Chughtai, Abrar Ahmad; Seale, Holly; Dung, Tham Chi; Hayen, Andrew; Rahman, Bayzidur; Raina MacIntyre, C

    2016-06-01

    Masks are often worn in healthcare settings to prevent the spread of infection from healthcare workers (HCWs) to patients. Masks are also used to protect the employee from patient-generated infectious organisms but poor compliance can reduce efficacy. The aim of this study was to examine the factors influencing compliance with the use of medical and cloth masks amongst hospital HCWs. HCWs compliance with the use of medical and cloth masks was measured over a 4-week period in a randomized controlled trial in Vietnam. HCWs were instructed to record their daily activities in diary cards. Demographic, clinical, and diary card data were used to determine the predictors of compliance and the relationship of compliance with infection outcomes. Compliance rates for both medical and cloth masks decreased during the 4 weeks: medical mask use decreased from 77 to 68% (P < 0.001) and cloth masks from 78 to 69% (P < 0.001). The presence of adverse events (adjusted RR 0.90, 95% CI 0.85-0.95), and performing aerosol-generating procedures (adjusted RR 0.78, 95% CI 0.73-0.82) were negatively associated with compliance, while contact with febrile respiratory illness patients was positively associated (adjusted RR 1.14, 95% CI 1.07-1.20). Being compliant with medical or cloth masks use (average use ≥70% of working time) was not associated with clinical respiratory illness, influenza-like illness, and laboratory-confirmed viral infection. Understanding the factors that affect compliance is important for the occupational health and safety of HCWs. New strategies and tools should be developed to increase compliance of HCWs. The presence of adverse events such as discomfort and breathing problems may be the main reasons for the low compliance with mask use and further studies should be conducted to improve the design/material of masks to improve comfort for the wearer. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  10. Associative and repetition priming with the repeated masked prime technique: no priming found.

    PubMed

    Avons, S E; Russo, Riccardo; Cinel, Caterina; Verolini, Veronica; Glynn, Kevin; McDonald, Rebecca; Cameron, Marie

    2009-01-01

    Wentura and Frings (2005) reported evidence of subliminal categorical priming on a lexical decision task, using a new method of visual masking in which the prime string consisted of the prime word flanked by random consonants and random letter masks alternated with the prime string on successive refresh cycles. We investigated associative and repetition priming on lexical decision, using the same method of visual masking. Three experiments failed to show any evidence of associative priming, (1) when the prime string was fixed at 10 characters (three to six flanking letters) and (2) when the number of flanking letters were reduced or absent. In all cases, prime detection was at chance level. Strong associative priming was observed with visible unmasked primes, but the addition of flanking letters restricted priming even though prime detection was still high. With repetition priming, no priming effects were found with the repeated masked technique, and prime detection was poor but just above chance levels. We conclude that with repeated masked primes, there is effective visual masking but that associative priming and repetition priming do not occur with experiment-unique prime-target pairs. Explanations for this apparent discrepancy across priming paradigms are discussed. The priming stimuli and prime-target pairs used in this study may be downloaded as supplemental materials from mc.psychonomic-journals.org/content/supplemental.

  11. History and future of mask making

    NASA Astrophysics Data System (ADS)

    Levy, Ken L.

    1996-12-01

    The history of the mask industry has three main periods, which I call the Classical Period, the Dark Ages, and the Renaissance, by analogy with those periods in the history of Western Europe. During the Classical Period, people developed 1X masks and the technology to make them. In the Dark Ages, people exploited the equipment developed during the Classical Period to make 5X reduction reticle, ending the nobility of mask making. In today's Renaissance of mask making, a proliferation of mask types is requiring a rebirth of innovation and creativity. The Renaissance resembles the Classical Period: masks are once again strategic, and technological capability is once again the driver. Meanwhile, the mask industry is carrying forward the productivity and efficiency gains it achieved during the Dark Ages. We must create a new business and economic model to support these changes in the characteristics of the marketplace.

  12. Assessing validity of observational intervention studies - the Benchmarking Controlled Trials.

    PubMed

    Malmivaara, Antti

    2016-09-01

    Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. To create and pilot test a checklist for appraising methodological validity of a BCT. The checklist was created by extracting the most essential elements from the comprehensive set of criteria in the previous paper on BCTs. Also checklists and scientific papers on observational studies and respective systematic reviews were utilized. Ten BCTs published in the Lancet and in the New England Journal of Medicine were used to assess feasibility of the created checklist. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. However, the piloted checklist should be validated in further studies. Key messages Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. This paper presents a checklist for appraising methodological validity of BCTs and pilot-tests the checklist with ten BCTs published in leading medical journals. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies.

  13. Illusionary delusions. Willingness to exercise self-control can mask effects of glucose on self-control performance in experimental paradigms that use identical self-control tasks.

    PubMed

    Chatzisarantis, Nikos L D; Hagger, Martin S

    2015-01-01

    The purpose of the present article is to highlight limitations of Lange and Eggert's methodology of using identical self-control tasks in testing effects of glucose on depletion of self-control resources and self-control performance. We suggest that when participants engage in two identical self-control tasks, cognitions developed during initial act of self-control may mask the effects of glucose on self-control performance by undermining willingness to exert effort during the second act of self-control. As a consequence, glucose may increase ability to exercise self-control but participants may not want to capitalize on this "ability advantage" because they are unwilling to exercise self-control. The present article concludes that researchers who test the glucose hypothesis in the context of a depletion paradigm should employ dissimilar acts of self-control and ensure that depleted participants are sufficiently motivated to exercise self-control. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  14. Masked translation priming effects with low proficient bilinguals.

    PubMed

    Dimitropoulou, Maria; Duñabeitia, Jon Andoni; Carreiras, Manuel

    2011-02-01

    Non-cognate masked translation priming lexical decision studies with unbalanced bilinguals suggest that masked translation priming effects are asymmetric as a function of the translation direction (significant effects only in the dominant [L1] to nondominant [L2] language translation direction). However, in contrast to the predictions of most current accounts of masked translation priming effects, bidirectional effects have recently been reported with a group of low proficient bilinguals Duyck & Warlop 2009 (Experimental Psychology 56:173-179). In a series of masked translation priming lexical decision experiments we examined whether the same pattern of effects would emerge with late and low proficient Greek (L1)-Spanish (L2) bilinguals. Contrary to the results obtained by Duyck and Warlop, and in line with the results found in most studies in the masked priming literature, significant translation priming effects emerged only when the bilinguals performed the task with L1 primes and L2 targets. The existence of the masked translation priming asymmetry with low proficient bilinguals suggests that cross-linguistic automatic lexico-semantic links may be established very early in the process of L2 acquisition. These findings could help to define models of bilingualism that consider L2 proficiency level to be a determining factor.

  15. Quartz 9-inch size mask blanks for ArF PSM (Phase Shift Mask)

    NASA Astrophysics Data System (ADS)

    Harashima, Noriyuki; Isozaki, Tatsuya; Kawanishi, Arata; Kanai, Shuichiro; Kageyama, Kagehiro; Iso, Hiroyuki; Chishima, Tatsuya

    2017-07-01

    Semiconductor technology nodes are steadily miniaturizing. On the other hand, various efforts have been made to reduce costs, mass production lines have shifted from 200 mmφ of Si wafer to 300 mmφ, and technology development of Si wafer 450 mmφ is also in progress. As a photomask, 6-inch size binary Cr mask has been used for many years, but in recent years, the use of 9-inch binary Cr masks for Proximity Lithography Process in automotive applications, MEMS, packages, etc. has increased, and cost reduction has been taken. Since the miniaturization will progress in the above applications in the future, products corresponding to miniaturization are also desired in 9-inch photomasks. The high grade Cr - binary mask blanks used in proximity exposure process, there is a prospect of being able to use it by ULVAC COATING CORPORATION's tireless research. As further demands for miniaturization, KrF and ArF Lithography Process, which are used for steppers and scanners , there are also a demand for 9-inch size Mask Blanks. In ULVAC COATING CORPORATION, we developed a 9 - inch size KrF PSM mask Blanks prototype in 2016 and proposed a new high grade 9 - inch photomask. This time, we have further investigated and developed 9-inch size ArF PSM Mask Blanks corresponding to ArF Lithography Process, so we report it.

  16. The attentional blink is not affected by backward masking of T2, T2-mask SOA, or level of T2 impoverishment.

    PubMed

    Jannati, Ali; Spalek, Thomas M; Lagroix, Hayley E P; Di Lollo, Vincent

    2012-02-01

    Identification of the second of two targets (T2) is impaired when presented shortly after the first (T1). This attentional blink (AB) is thought to arise from a delay in T2 processing during which T2 is vulnerable to masking. Conventional studies have measured T2 accuracy which is constrained by the 100% ceiling. We avoided this problem by using a dynamic threshold-tracking procedure that is inherently free from ceiling constraints. In two experiments we examined how AB magnitude is affected by three masking-related factors: (a) presence/absence of T2 mask, (b) T2-mask stimulus onset asynchrony (SOA), and (c) level of T2 impoverishment (signal-to-noise ratio [SNR]). In Experiment 1, overall accuracy decreased with T2-mask SOA. The magnitude of the AB, however, was invariant with SOA and with mask presence/absence. Experiment 2 further showed that the AB was invariant with T2 SNR. The relationship among mask presence/absence, SOA, and T2 SNR and the AB is encompassed in a qualitative model.

  17. Forward masking as a mechanism of automatic gain control in odontocete biosonar: a psychophysical study.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2008-07-01

    In a false killer whale Pseudorca crassidens, echo perception thresholds were measured using a go/no-go psychophysical paradigm and one-up-one-down staircase procedure. Computer controlled echoes were electronically synthesized pulses that were played back through a transducer and triggered by whale emitted biosonar pulses. The echo amplitudes were proportional to biosonar pulse amplitudes; echo levels were specified in terms of the attenuation of the echo sound pressure level near the animal's head relative to the source level of the biosonar pulses. With increasing echo delay, the thresholds (echo attenuation factor) decreased from -49.3 dB at 2 ms to -79.5 dB at 16 ms, with a regression slope of -9.5 dB per delay doubling (-31.5 dB per delay decade). At the longer delays, the threshold remained nearly constant around -80.4 dB. Levels of emitted pulses slightly increased with delay prolongation (threshold decrease), with a regression slope of 3.2 dB per delay doubling (10.7 dB per delay decade). The echo threshold dependence on delay is interpreted as a release from forward masking by the preceding emitted pulse. This release may compensate for the echo level decrease with distance, thus keeping the echo sensation level for the animal near constant within a certain distance range.

  18. Noninvasive CPAP with face mask: comparison among new air-entrainment masks and the Boussignac valve.

    PubMed

    Mistraletti, Giovanni; Giacomini, Matteo; Sabbatini, Giovanni; Pinciroli, Riccardo; Mantovani, Elena S; Umbrello, Michele; Palmisano, Debora; Formenti, Paolo; Destrebecq, Anne L L; Iapichino, Gaetano

    2013-02-01

    The performances of 2 noninvasive CPAP systems (high flow and low flow air-entrainment masks) were compared to the Boussignac valve in 3 different scenarios. Scenario 1: pneumatic lung simulator with a tachypnea pattern (tidal volume 800 mL at 40 breaths/min). Scenario 2: Ten healthy subjects studied during tidal breaths and tachypnea. Scenario 3: Twenty ICU subjects enrolled for a noninvasive CPAP session. Differences between set and effective CPAP level and F(IO(2)), as well as the lowest airway pressure and the pressure swing around the imposed CPAP level, were analyzed. The lowest airway pressure and swing were correlated to the pressure-time product (area of the airway pressure curve below the CPAP level) measured with the simulator. P(aO(2)) was a subject's further performance index. Lung simulator: Boussignac F(IO(2)) was 0.54, even if supplied with pure oxygen. The air-entrainment masks had higher swing than the Boussignac (P = .007). Pressure-time product correlated better with pressure swing (Spearman correlation coefficient [ρ] = 0.97) than with lowest airway pressure (ρ = 0.92). In healthy subjects, the high-flow air-entrainment mask showed lower difference between set and effective F(IO(2)) (P < .001), and lowest airway pressure (P < .001), compared to the Boussignac valve. In all measurements the Boussignac valve showed higher than imposed CPAP level (P < .001). In ICU subjects the high-flow mask had lower swing than the Boussignac valve (P = .03) with similar P(aO(2)) increase. High-flow air-entrainment mask showed the best performance in human subjects. During high flow demand, the Boussignac valve delivered lower than expected F(IO(2)) and showed higher dynamic hyper-pressurization than the air-entrainment masks. © 2013 Daedalus Enterprises.

  19. Mask industry assessment trend analysis

    NASA Astrophysics Data System (ADS)

    Shelden, Gilbert; Marmillion, Patricia; Hughes, Greg

    2008-04-01

    Microelectronics industry leaders routinely name the cost and cycle time of mask technology and mask supply as top critical issues. A survey was created with support from SEMATECH and administered by SEMI North America to gather information about the mask industry as an objective assessment of its overall condition. This year's survey data were presented in detail at BACUS and the detailed trend analysis presented at EMLC. The survey is designed with the input of semiconductor company mask technologists, merchant mask suppliers, and industry equipment makers. This year's assessment is the sixth in the current series of annual reports. With continued industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. The results will be used to guide future investments on critical path issues. This year's survey is basically the same as the 2005 and 2006 surveys. Questions are grouped into eight categories: General Business Profile Information, Data Processing, Yields and Yield Loss, Mechanisms, Delivery Times, Returns and Services, Operating Cost Factors, and Equipment Utilization. Within each category is a multitude of questions that creates a detailed profile of both the business and technical status of the critical mask industry. Note: the questions covering operating cost factors and equipment utilization were added to the survey only in 2005; therefore, meaningful trend analysis is not available.

  20. Computing Challenges in Coded Mask Imaging

    NASA Technical Reports Server (NTRS)

    Skinner, Gerald

    2009-01-01

    This slide presaentation reviews the complications and challenges in developing computer systems for Coded Mask Imaging telescopes. The coded mask technique is used when there is no other way to create the telescope, (i.e., when there are wide fields of view, high energies for focusing or low energies for the Compton/Tracker Techniques and very good angular resolution.) The coded mask telescope is described, and the mask is reviewed. The coded Masks for the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) instruments are shown, and a chart showing the types of position sensitive detectors used for the coded mask telescopes is also reviewed. Slides describe the mechanism of recovering an image from the masked pattern. The correlation with the mask pattern is described. The Matrix approach is reviewed, and other approaches to image reconstruction are described. Included in the presentation is a review of the Energetic X-ray Imaging Survey Telescope (EXIST) / High Energy Telescope (HET), with information about the mission, the operation of the telescope, comparison of the EXIST/HET with the SWIFT/BAT and details of the design of the EXIST/HET.

  1. Masking of sounds by a background noise--cochlear mechanical correlates.

    PubMed

    Recio-Spinoso, Alberto; Cooper, Nigel P

    2013-05-15

    In the search for cochlear correlates of auditory masking by noise stimuli, we recorded basilar membrane (BM) vibrations evoked by either tone or click signals in the presence of varying levels of background noise. The BM vibrations were recorded from basal regions in healthy cochleae of anaesthetized chinchilla and gerbil. Non-linear interactions that could underpin various aspects of psychophysical masking data, including both compression and suppression at the BM level, were observed. The suppression effects, whereby the amplitude of the responses to each stimulus component could be reduced, depended on the relative intensities of the noise and the tones or clicks. Only stimulus components whose frequencies fell inside the non-linear region of the recording site, i.e. around its characteristic frequency (CF), were affected by presentation of the 'suppressing' stimulus (which could be either the tone or the noise). Mutual suppression, the simultaneous reduction of the responses to both tones and noise components, was observed under some conditions, but overall reductions of BM vibration were rarely observed. Moderate- to high-intensity tones suppressed BM responses to low-intensity Gaussian stimuli, including both broadband and narrowband noise. Suppression effects were larger for spectral components of the noise response that were closer to the CF. In this regime, the tone and noise stimuli became the suppressor and probe signals, respectively. This study provides the first detailed observations of cochlear mechanical correlates of the masking effects of noise. Mechanical detection thresholds for tone signals, which were arbitrarily defined using three criteria, are shown to increase in almost direct proportion to the noise level for low and moderately high noise levels, in a manner that resembles the findings of numerous psychophysical observations.

  2. UNMASKING MASKED HYPERTENSION: PREVALENCE, CLINICAL IMPLICATIONS, DIAGNOSIS, CORRELATES, AND FUTURE DIRECTIONS

    PubMed Central

    Peacock, James; Diaz, Keith M.; Viera, Anthony J.; Schwartz, Joseph E.; Shimbo, Daichi

    2014-01-01

    Masked hypertension’ is defined as having non-elevated clinic blood pressure (BP) with elevated out-of-clinic average BP, typically determined by ambulatory BP monitoring. Approximately 15–30% of adults with non-elevated clinic BP have masked hypertension. Masked hypertension is associated with increased risks of cardiovascular morbidity and mortality compared to sustained normotension (non-elevated clinic and ambulatory BP), which is similar to or approaching the risk associated with sustained hypertension (elevated clinic and ambulatory BP). The confluence of increased cardiovascular risk and a failure to be diagnosed by the conventional approach of clinic BP measurement makes masked hypertension a significant public health concern. However, many important questions remain. First, the definition of masked hypertension varies across studies. Further, the best approach in the clinical setting to exclude masked hypertension also remains unknown. It is unclear whether home BP monitoring is an adequate substitute for ambulatory BP monitoring in identifying masked hypertension. Few studies have examined the mechanistic pathways that may explain masked hypertension. Finally, scarce data are available on the best approach to treating individuals with masked hypertension. Herein, we review the current literature on masked hypertension including definition, prevalence, clinical implications, special patient populations, correlates, issues related to diagnosis, treatment, and areas for future research. PMID:24573133

  3. Orion Emergency Mask Approach

    NASA Technical Reports Server (NTRS)

    Tuan, George C.; Graf, John C.

    2008-01-01

    Emergency mask approach on Orion poses a challenge to the traditional Shuttle or Station approaches. Currently, in the case of a fire or toxic spill event, the crew utilizes open loop oxygen masks that provide the crew with oxygen to breath, but also dumps the exhaled oxygen into the cabin. For Orion, with a small cabin volume, the extra oxygen will exceed the flammability limit within a short period of time, unless a nitrogen purge is also provided. Another approach to a fire or toxic spill event is the use of a filtering emergency masks. These masks utilize some form of chemical beds to scrub the air clean of toxic providing the crew safe breathing air for a period without elevating the oxygen level in the cabin. Using the masks and a form of smoke-eater filter, it may be possible to clean the cabin completely or to a level for safe transition to a space suit to perform a cabin purge. Issues with filters in the past have been the reaction temperature and high breathing resistance. Development in a new form of chemical filters has shown promise to make the filtering approach feasible.

  4. Orion Emergency Mask Approach

    NASA Technical Reports Server (NTRS)

    Tuan, George C.; Graf, John C.

    2009-01-01

    Emergency mask approach on Orion poses a challenge to the traditional Shuttle or Station approaches. Currently, in the case of a fire or toxic spill event, the crew utilizes open loop oxygen masks that provide the crew with oxygen to breath, but also dumps the exhaled oxygen into the cabin. For Orion, with a small cabin volume, the extra oxygen will exceed the flammability limit within a short period of time, unless a nitrogen purge is also provided. Another approach to a fire or toxic spill event is the use of a filtering emergency masks. These masks utilize some form of chemical beds to scrub the air clean of toxic providing the crew safe breathing air for a period without elevating the oxygen level in the cabin. Using the masks and a form of smoke-eater filter, it may be possible to clean the cabin completely or to a level for safe transition to a space suit to perform a cabin purge. Issues with filters in the past have been the reaction time, breakthroughs, and high breathing resistance. Development in a new form of chemical filters has shown promise to make the filtering approach feasible.

  5. Prevalence, Determinants, and Clinical Significance of Masked Hypertension in a Population-Based Sample of African Americans: The Jackson Heart Study.

    PubMed

    Diaz, Keith M; Veerabhadrappa, Praveen; Brown, Michael D; Whited, Matthew C; Dubbert, Patricia M; Hickson, DeMarc A

    2015-07-01

    The disproportionate rates of cardiovascular disease in African Americans may, in part, be due to suboptimal assessment of blood pressure (BP) with clinic BP measurements alone. To date, however, the prevalence of masked hypertension in African Americans has not been fully delineated. The purpose of this study was to evaluate masked hypertension prevalence in a large population-based sample of African Americans and examine its determinants and association with indices of target organ damage (TOD). Clinic and 24-hour ambulatory BP monitoring were conducted in 972 African Americans enrolled in the Jackson Heart Study. Common carotid artery intima-media thickness, left ventricular mass index, and the urinary albumin:creatinine excretion ratio were evaluated as indices of TOD. Masked hypertension prevalence was 25.9% in the overall sample and 34.4% in participants with normal clinic BP. All indices of TOD were significantly higher in masked hypertensives compared to sustained normotensives and were similar between masked hypertensives and sustained hypertensives. Male gender, smoking, diabetes, and antihypertensive medication use were independent determinants of masked hypertension in multivariate analyses. In this population-based cohort of African Americans, approximately one-third of participants with presumably normal clinic BP had masked hypertension when BP was assessed in their daily environment. Masked hypertension was accompanied by a greater degree of TOD in this cohort. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Akathisia masked by hypokinesia.

    PubMed

    Tuisku, K; Lauerma, H; Holi, M M; Honkonen, T; Rimon, R

    2000-07-01

    Here, we will discuss the concept of subjective akathisia and present a patient case. Our patient was suffering from neuroleptic-induced hypokinesia and akathisia at the same time. The typical motor manifestations of akathisia were masked by hypokinesia, which made the diagnosis difficult. However, the subjective symptoms of akathisia were evident and distressing. Although not observable to bare eye, the pathognomonic pattern of motor activity detected in akathisia was demonstrated by actometric recording. Changing the conventional neuroleptic to an atypical one brought relief to the subjective symptoms of akathisia and hypokinesia, while the motor activity was clearly diminished in actometric recording. Actometric recording may be useful in diagnosing akathisia masked by hypokinesia, but the typical subjective symptoms of akathisia should not be ignored, even when actometry is not available to demonstrate the missing motor component of akathisia. Not only akathisia defined by DSM-IV but also subjective akathisia should be adequately treated to relieve the subjective distress, and to diminish the unfavorable effects on psychotic symptoms, behavior, and drug compliance.

  7. A computational investigation of feedforward and feedback processing in metacontrast backward masking

    PubMed Central

    Silverstein, David N.

    2015-01-01

    In human perception studies, visual backward masking has been used to understand the temporal dynamics of subliminal vs. conscious perception. When a brief target stimulus is followed by a masking stimulus after a short interval of <100 ms, performance on the target is impaired when the target and mask are in close spatial proximity. While the psychophysical properties of backward masking have been studied extensively, there is still debate on the underlying cortical dynamics. One prevailing theory suggests that the impairment of target performance due to the mask is the result of lateral inhibition between the target and mask in feedforward processing. Another prevailing theory suggests that this impairment is due to the interruption of feedback processing of the target by the mask. This computational study demonstrates that both aspects of these theories may be correct. Using a biophysical model of V1 and V2, visual processing was modeled as interacting neocortical attractors, which must propagate up the visual stream. If an activating target attractor in V1 is quiesced enough with lateral inhibition from a mask, or not reinforced by recurrent feedback, it is more likely to burn out before becoming fully active and progressing through V2 and beyond. Results are presented which simulate metacontrast backward masking with an increasing stimulus interval and with the presence and absence of feedback activity. This showed that recurrent feedback diminishes backward masking effects and can make conscious perception more likely. One model configuration presented a metacontrast noise mask in the same hypercolumns as the target, and produced type-A masking. A second model configuration presented a target line with two parallel adjacent masking lines, and produced type-B masking. Future work should examine how the model extends to more complex spatial mask configurations. PMID:25759672

  8. Impact of the flu mask regulation on health care personnel influenza vaccine acceptance rates.

    PubMed

    Edwards, Frances; Masick, Kevin D; Armellino, Donna

    2016-10-01

    Achieving high vaccination rates of health care personnel (HCP) is critical in preventing influenza transmission from HCP to patients and from patients to HCP; however, acceptance rates remain low. In 2013, New York State adopted the flu mask regulation, requiring unvaccinated HCP to wear a mask when in areas where patients are present. The purpose of this study assessed the impact of the flu mask regulation on the HCP influenza vaccination rate. A 13-question survey was distributed electronically and manually to the HCP to examine their knowledge of influenza transmission and the influenza vaccine and their personal vaccine acceptance history and perception about the use of the mask while working if not vaccinated. There were 1,905 respondents; 87% accepted the influenza vaccine, and 63% were first-time recipients who agreed the regulation influenced their vaccination decision. Of the respondents who declined the vaccine, 72% acknowledge HCP are at risk for transmitting influenza to patients, and 56% reported they did not receive enough information to make an educated decision. The flu mask protocol may have influenced HCP's choice to be vaccinated versus wearing a mask. The study findings supported that HCP may not have adequate knowledge on the morbidity and mortality associated with influenza. Regulatory agencies need to consider an alternative approach to increase HCP vaccination, such as mandating the influenza vaccine for HCP. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Mitigation and control of the overcuring effect in mask projection micro-stereolithography

    NASA Astrophysics Data System (ADS)

    O'Neill, Paul F.; Kent, Nigel; Brabazon, Dermot

    2017-10-01

    Mask Projection micro-Stereolithography (MPμSL) is an additive manufacturing technique capable of producing solid parts with micron-scale resolution from a vat of photocurable liquid polymer resin. Although the physical mechanism remains the same, the process differs from traditional laser-galvanometer based stereolithography (SL) in its use of a dynamic mask UV projector, or digital light processor (DLP), which cures each location within each 3D layer at the same time. One area where MPµSL has garnered considerable attention is in the field of microfluidics and Lab-on-a-Chip, where complex multistep microfabrication techniques adopted from the semiconductor industry are still widely used, and where MPµSL offers the ability to fabricate completely encapsulated fluidic channels in a single step and at low cost [1-3]. However, a significant obstacle exists in the prevention of channel blockage due to overcuring of the polymer resin [4, 5]. Overcuring can be attributed to the so-called `back side effect' [2] which occurs during the build process as light from successive layers penetrates into the resin to a depth greater than the layer thickness. This effect is most prevalent in channels or features oriented horizontally (in a parallel plane to that of the build platform). Currently there are two main approaches in controlling the cure depth; 1. the chemical approach, which involves doping the resin material with a chemical light absorber [6-8]; and 2. by improving the system's hardware and optical elements to improve the homogeneity of the light dosage and control the cure depth [9]. Here we investigate a third approach through modification of the 3D CAD file prior to printing to mitigate for UV light leakage from successive build layers. Although used here in conjunction with the MPμSL technique, this approach can be applied to a range of SL techniques to improve printer resolution and enable production of internal features with higher dimensional accuracy.

  10. JAPE 91: Influence of terrain masking of the acoustic propagation of helicopter noise

    NASA Technical Reports Server (NTRS)

    Naz, P.

    1993-01-01

    The acoustic propagation in the case of a noise source masked by a small element of terrain has been investigated experimentally. These data have been measured during the 'terrain masking' experiment of the NATO JAPE 91 experimental campaign. The main objective of that experiment was to study the acoustic detection of a helicopter masked by a small hill. Microphones have been placed at different locations on the shadow zone of the hill to study the effect of the terrain obstruction on sound propagation. The results presented come from data measured by Atlas Elektronik and by ISL, and have been processed together. The terrain obstruction causes an excess attenuation of the SPL (Sound Pressure Level) for all the frequencies, but this attenuation is more effective for the high frequencies than for the low frequencies. Results typical of diffraction phenomena have been observed; the SPL is minimal at the foot of the hill and is relatively constant beyond it.

  11. Migration from full-head mask to "open-face" mask for immobilization of patients with head and neck cancer.

    PubMed

    Li, Guang; Lovelock, D Michael; Mechalakos, James; Rao, Shyam; Della-Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-09-06

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an "open-face" thermoplastic mask was evaluated using video-based optical surface imaging (OSI) and kilovoltage (kV) X-ray radiography. A three-point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real-time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open-face and full-head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open-face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real-time OSI. With the open-face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre-/post-treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask-locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open-face and full-head masks were found to be similar. Most (80%) of the volunteers preferred the open-face mask to the full-head mask, while claustrophobic patients could only tolerate the open-face mask. The open-face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open-face mask is readily adopted in radiotherapy clinic as a superior alternative

  12. Masking Treatment and its Effect on Tinnitus Parameters.

    PubMed

    Aytac, Ismail; Baysal, Elif; Gulsen, Secaattin; Tumuklu, Koray; Durucu, Cengiz; Mumbuc, Lütfi Semih; Kanlikama, MUzaffer

    2017-12-01

    Tinnitus is described as the perception of sound without any external acoustic stimulation. Any pathology of auditory pathways or any system of the human body may result with tinnitus. The pathophysiology of tinnitus accompanying the disorders of auditory system is not fully understood and there is not any particular effective treatment method has been specified. Tinnitus masking therapy has been reported as an effective treatment modality in the treatment of tinnitus. In this study, the results of tinnitus masking treatment on the parameters were evaluated prospectively. Patients with normal physical examination was enrolled in the study. Blood tests (complete blood count, biochemical analysis of lipid profile, and thyroid hormones), pure tone audiometry, tympanometric measurement of the middle ear pressure and stapedial reflexes were performed, Sixty six patients with normal results of blood tests and normal hearing thresholds with type A tympanogram were included. Tinnitus sufferers questionnaires (socio-demographics, clinical information, Tinnitus Handicap Inventory (THI), Beck Depression Inventory (BDI) was filled, audiological tests were performed, tinnitus parameters (frequency, intensity, minimal masking levels, residual inhibition) were measured. After four weeks of the treatment the questionnaires were repeated. Masking treatment for tinnitus patients resulted with significant decrease in Tinnitus Handicap Inventory and VAS scores. After four weeks of the masking treatment the questionnaire was repeated. Twenty patients did not respond to treatment. Masking therapy is one of the most effective methods of treatment for tinnitus patients. Masking therapy, that is not invasive and cost-effective has an important place in the treatment of tinnitus. Especially in a short time provides a significant reduction in tinnitus parameters.

  13. What Do Contrast Threshold Equivalent Noise Studies Actually Measure? Noise vs. Nonlinearity in Different Masking Paradigms.

    PubMed

    Baldwin, Alex S; Baker, Daniel H; Hess, Robert F

    2016-01-01

    The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system's input has on its output one can estimate the variance of this internal noise. By applying this simple "linear amplifier" model to the human visual system, one can entirely explain an observer's detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system's internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity). Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF). We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies.

  14. Temporal masking functions for listeners with real and simulated hearing loss

    PubMed Central

    Desloge, Joseph G.; Reed, Charlotte M.; Braida, Louis D.; Perez, Zachary D.; Delhorne, Lorraine A.

    2011-01-01

    A functional simulation of hearing loss was evaluated in its ability to reproduce the temporal masking functions for eight listeners with mild to severe sensorineural hearing loss. Each audiometric loss was simulated in a group of age-matched normal-hearing listeners through a combination of spectrally-shaped masking noise and multi-band expansion. Temporal-masking functions were obtained in both groups of listeners using a forward-masking paradigm in which the level of a 110-ms masker required to just mask a 10-ms fixed-level probe (5-10 dB SL) was measured as a function of the time delay between the masker offset and probe onset. At each of four probe frequencies (500, 1000, 2000, and 4000 Hz), temporal-masking functions were obtained using maskers that were 0.55, 1.0, and 1.15 times the probe frequency. The slopes and y-intercepts of the masking functions were not significantly different for listeners with real and simulated hearing loss. The y-intercepts were positively correlated with level of hearing loss while the slopes were negatively correlated. The ratio of the slopes obtained with the low-frequency maskers relative to the on-frequency maskers was similar for both groups of listeners and indicated a smaller compressive effect than that observed in normal-hearing listeners. PMID:21877806

  15. MEG masked priming evidence for form-based decomposition of irregular verbs

    PubMed Central

    Fruchter, Joseph; Stockall, Linnaea; Marantz, Alec

    2013-01-01

    To what extent does morphological structure play a role in early processing of visually presented English past tense verbs? Previous masked priming studies have demonstrated effects of obligatory form-based decomposition for genuinely affixed words (teacher-TEACH) and pseudo-affixed words (corner-CORN), but not for orthographic controls (brothel-BROTH). Additionally, MEG single word reading studies have demonstrated that the transition probability from stem to affix (in genuinely affixed words) modulates an early evoked response known as the M170; parallel findings have been shown for the transition probability from stem to pseudo-affix (in pseudo-affixed words). Here, utilizing the M170 as a neural index of visual form-based morphological decomposition, we ask whether the M170 demonstrates masked morphological priming effects for irregular past tense verbs (following a previous study which obtained behavioral masked priming effects for irregulars). Dual mechanism theories of the English past tense predict a rule-based decomposition for regulars but not for irregulars, while certain single mechanism theories predict rule-based decomposition even for irregulars. MEG data was recorded for 16 subjects performing a visual masked priming lexical decision task. Using a functional region of interest (fROI) defined on the basis of repetition priming and regular morphological priming effects within the left fusiform and inferior temporal regions, we found that activity in this fROI was modulated by the masked priming manipulation for irregular verbs, during the time window of the M170. We also found effects of the scores generated by the learning model of Albright and Hayes (2003) on the degree of priming for irregular verbs. The results favor a single mechanism account of the English past tense, in which even irregulars are decomposed into stems and affixes prior to lexical access, as opposed to a dual mechanism model, in which irregulars are recognized as whole forms

  16. Clinical efficacy and safety of a novel tetravalent dengue vaccine in healthy children in Asia: a phase 3, randomised, observer-masked, placebo-controlled trial.

    PubMed

    Capeding, Maria Rosario; Tran, Ngoc Huu; Hadinegoro, Sri Rezeki S; Ismail, Hussain Imam H J Muhammad; Chotpitayasunondh, Tawee; Chua, Mary Noreen; Luong, Chan Quang; Rusmil, Kusnandi; Wirawan, Dewa Nyoman; Nallusamy, Revathy; Pitisuttithum, Punnee; Thisyakorn, Usa; Yoon, In-Kyu; van der Vliet, Diane; Langevin, Edith; Laot, Thelma; Hutagalung, Yanee; Frago, Carina; Boaz, Mark; Wartel, T Anh; Tornieporth, Nadia G; Saville, Melanie; Bouckenooghe, Alain

    2014-10-11

    An estimated 100 million people have symptomatic dengue infection every year. This is the first report of a phase 3 vaccine efficacy trial of a candidate dengue vaccine. We aimed to assess the efficacy of the CYD dengue vaccine against symptomatic, virologically confirmed dengue in children. We did an observer-masked, randomised controlled, multicentre, phase 3 trial in five countries in the Asia-Pacific region. Between June 3, and Dec 1, 2011, healthy children aged 2-14 years were randomly assigned (2:1), by computer-generated permuted blocks of six with an interactive voice or web response system, to receive three injections of a recombinant, live, attenuated, tetravalent dengue vaccine (CYD-TDV), or placebo, at months 0, 6, and 12. Randomisation was stratified by age and site. Participants were followed up until month 25. Trial staff responsible for the preparation and administration of injections were unmasked to group allocation, but were not included in the follow-up of the participants; allocation was concealed from the study sponsor, investigators, and parents and guardians. Our primary objective was to assess protective efficacy against symptomatic, virologically confirmed dengue, irrespective of disease severity or serotype, that took place more than 28 days after the third injection. The primary endpoint was for the lower bound of the 95% CI of vaccine efficacy to be greater than 25%. Analysis was by intention to treat and per procotol. This trial is registered with ClinicalTrials.gov, number NCT01373281. We randomly assigned 10,275 children to receive either vaccine (n=6851) or placebo (n=3424), of whom 6710 (98%) and 3350 (98%), respectively, were included in the primary analysis. 250 cases of virologically confirmed dengue took place more than 28 days after the third injection (117 [47%] in the vaccine group and 133 [53%] in the control group). The primary endpoint was achieved with 56·5% (95% CI 43·8-66·4) efficacy. We recorded 647 serious adverse

  17. Feasibility of aerosol drug delivery to sleeping infants: a prospective observational study.

    PubMed

    Amirav, Israel; Newhouse, Michael T; Luder, Anthony; Halamish, Asaf; Omar, Hamza; Gorenberg, Miguel

    2014-03-26

    Delivery of inhaled medications to infants is usually very demanding and is often associated with crying and mask rejection. It has been suggested that aerosol administration during sleep may be an attractive alternative. Previous studies in sleeping children were disappointing as most of the children awoke and rejected the treatment. The SootherMask (SM) is a new, gentle and innovative approach for delivering inhaled medication to infants and toddlers. The present pilot study describes the feasibility of administering inhaled medications during sleep using the SM. Prospective observational study. Out patients. 13 sleeping infants with recurrent wheezing who regularly used pacifiers and were <12 months old. Participants inhaled technetium99mDTPA-labelled normal saline aerosol delivered via a Respimat Soft Mist Inhaler (SMI) (Boehringer-Ingelheim, Germany) and SM + InspiraChamber (IC; InspiRx Inc, New Jersey, USA). The two major outcomes were the acceptability of the treatment and the lung deposition (per cent of emitted dose). All infants who fulfilled the inclusion criteria successfully received the SM treatment during sleep without difficulty. Mean lung deposition (±SD) averaged 1.6±0.5% in the right lung. This study demonstrated that the combination of Respimat, IC and SM was able to administer aerosol therapy to all the sleeping infants who were regular pacifier users with good lung deposition. Administration of aerosols during sleep is advantageous since all the sleeping children accepted the mask and ensuing aerosol therapy under these conditions, in contrast to previous studies in which there was frequent mask rejection using currently available devices. NCT01120938.

  18. A new mask exposure and analysis facility

    NASA Astrophysics Data System (ADS)

    te Sligte, Edwin; Koster, Norbert; Deutz, Alex; Staring, Wilbert

    2014-10-01

    The introduction of ever higher source powers in EUV systems causes increased risks for contamination and degradation of EUV masks and pellicles. Appropriate testing can help to inventory and mitigate these risks. To this end, we propose EBL2: a laboratory EUV exposure system capable of operating at high EUV powers and intensities, and capable of exposing and analyzing EUV masks. The proposed system architecture is similar to the EBL system which has been operated jointly by TNO and Carl Zeiss SMT since 2005. EBL2 contains an EUV Beam Line, in which samples can be exposed to EUV irradiation in a controlled environment. Attached to this Beam Line is an XPS system, which can be reached from the Beam Line via an in-vacuum transfer system. This enables surface analysis of exposed masks without breaking vacuum. Automated handling with dual pods is foreseen so that exposed EUV masks will still be usable in EUV lithography tools to assess the imaging impact of the exposure. Compared to the existing system, large improvements in EUV power, intensity, reliability, and flexibility are proposed. Also, in-situ measurements by e.g. ellipsometry is foreseen for real time monitoring of the sample condition. The system shall be equipped with additional ports for EUVR or other analysis tools. This unique facility will be open for external customers and other research groups.

  19. Defect tolerant transmission lithography mask

    DOEpatents

    Vernon, Stephen P.

    2000-01-01

    A transmission lithography mask that utilizes a transparent substrate or a partially transparent membrane as the active region of the mask. A reflective single layer or multilayer coating is deposited on the membrane surface facing the illumination system. The coating is selectively patterned (removed) to form transmissive (bright) regions. Structural imperfections and defects in the coating have negligible effect on the aerial image of the mask master pattern since the coating is used to reflect radiation out of the entrance pupil of the imaging system. Similarly, structural imperfections in the clear regions of the membrane have little influence on the amplitude or phase of the transmitted electromagnetic fields. Since the mask "discards," rather than absorbs, unwanted radiation, it has reduced optical absorption and reduced thermal loading as compared to conventional designs. For EUV applications, the mask circumvents the phase defect problem, and is independent of the thermal load during exposure.

  20. Culture, gender and health care stigma: Practitioners' response to facial masking experienced by people with Parkinson's disease.

    PubMed

    Tickle-Degnen, Linda; Zebrowitz, Leslie A; Ma, Hui-ing

    2011-07-01

    Facial masking in Parkinson's disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners' responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners' impressions of patient psychological attributes. Practitioners (N = 284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners' judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners' judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners' use of facial

  1. Mask industry assessment trend analysis: 2010

    NASA Astrophysics Data System (ADS)

    Hughes, Greg; Yun, Henry

    2010-05-01

    Microelectronics industry leaders consistently cite the cost and cycle time of mask technology and mask supply as top critical issues. A survey was designed with input from semiconductor company mask technologists and merchant mask suppliers and support from SEMATECH to gather information about the mask industry as an objective assessment of its overall condition. This year's assessment was the eighth in the current series of annual reports. Its data were presented in detail at BACUS, and the detailed trend analysis is presented at EMLC. With continued industry support, the report can be used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. The report will continue to serve as a valuable reference to identify the strengths and opportunities of the mask industry. Its results will be used to guide future investments on critical path issues. This year's survey is basically the same as the surveys in 2005 through 2009. Questions are grouped into six categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category is a multitude of questions that creates a detailed profile of both the business and technical status of the critical mask industry.

  2. An interactive tool for gamut masking

    NASA Astrophysics Data System (ADS)

    Song, Ying; Lau, Cheryl; Süsstrunk, Sabine

    2014-02-01

    Artists often want to change the colors of an image to achieve a particular aesthetic goal. For example, they might limit colors to a warm or cool color scheme to create an image with a certain mood or feeling. Gamut masking is a technique that artists use to limit the set of colors they can paint with. They draw a mask over a color wheel and only use the hues within the mask. However, creating the color palette from the mask and applying the colors to the image requires skill. We propose an interactive tool for gamut masking that allows amateur artists to create an image with a desired mood or feeling. Our system extracts a 3D color gamut from the 2D user-drawn mask and maps the image to this gamut. The user can draw a different gamut mask or locally refine the image colors. Our voxel grid gamut representation allows us to represent gamuts of any shape, and our cluster-based image representation allows the user to change colors locally.

  3. Nanoimprint wafer and mask tool progress and status for high volume semiconductor manufacturing

    NASA Astrophysics Data System (ADS)

    Matsuoka, Yoichi; Seki, Junichi; Nakayama, Takahiro; Nakagawa, Kazuki; Azuma, Hisanobu; Yamamoto, Kiyohito; Sato, Chiaki; Sakai, Fumio; Takabayashi, Yukio; Aghili, Ali; Mizuno, Makoto; Choi, Jin; Jones, Chris E.

    2016-10-01

    Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Jet and Flash* Imprint Lithography (J-FIL*) involves the field-by-field deposition and exposure of a low viscosity resist deposited by jetting technology onto the substrate. The patterned mask is lowered into the fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed, leaving a patterned resist on the substrate. There are many criteria that determine whether a particular technology is ready for wafer manufacturing. Defectivity and mask life play a significant role relative to meeting the cost of ownership (CoO) requirements in the production of semiconductor devices. Hard particles on a wafer or mask create the possibility of inducing a permanent defect on the mask that can impact device yield and mask life. By using material methods to reduce particle shedding and by introducing an air curtain system, the lifetime of both the master mask and the replica mask can be extended. In this work, we report results that demonstrate a path towards achieving mask lifetimes of better than 1000 wafers. On the mask side, a new replication tool, the FPA-1100 NR2 is introduced. Mask replication is required for nanoimprint lithography (NIL), and criteria that are crucial to the success of a replication platform include both particle control, resolution and image placement accuracy. In this paper we discuss the progress made in both feature resolution and in meeting the image placement specification for replica masks.

  4. Thin-plate spline analysis of the effects of face mask treatment in children with maxillary retrognathism.

    PubMed

    Chang, Jenny Zwei-Chieng; Liu, Pao-Hsin; Chen, Yi-Jane; Yao, Jane Chung-Chen; Chang, Hong-Po; Chang, Chih-Han; Chang, Frank Hsin-Fu

    2006-02-01

    Face mask therapy is indicated for growing patients who suffer from maxillary retrognathia. Most previous studies used conventional cephalometric analysis to evaluate the effects of face mask treatment. Cephalometric analysis has been shown to be insufficient for complex craniofacial configurations. The purpose of this study was to investigate changes in the craniofacial structure of children with maxillary retrognathism following face mask treatment by means of thin-plate spline analysis. Thirty children with skeletal Class III malocclusions who had been treated with face masks were compared with a group of 30 untreated gender-matched, age-matched, observation period-matched, and craniofacial configuration-matched subjects. Average geometries, scaled to an equivalent size, were generated by means of Procrustes analysis. Thin-plate spline analysis was then performed for localization of the shape changes. Face mask treatment induced a forward displacement of the maxilla, a counterclockwise rotation of the palatal plane, a horizontal compression of the anterior border of the symphysis and the condylar region, and a downward deformation of the menton. The cranial base exhibited a counterclockwise deformation as a whole. We conclude that thin-plate spline analysis is a valuable supplement to conventional cephalometric analysis.

  5. Masking ability of a zirconia ceramic on composite resin substrate shades.

    PubMed

    Tabatabaian, Farhad; Shabani, Sima; Namdari, Mahshid; Sadeghpour, Koroush

    2017-01-01

    Masking ability of a restorative material plays an important role to cover discolored tooth structure; however, this ability has not yet been well understood in zirconia-based restorations. This study assessed the masking ability of a zirconia ceramic on composite resin substrates with different shades. Ten zirconia disc specimens, with 0.5 mm thickness and 10 mm diameter, were fabricated by a computer-aided design/computer-aided manufacturing system. A white substrate (control) and six composite resin substrates with different shades including A1, A2, A3, B2, C2, and D3 were prepared. The substrates had a cylindrical shape with 10 mm diameter and height. The specimens were placed onto the substrates for spectrophotometric evaluation. A spectrophotometer measured the L*, a*, and b* values for the specimens. ΔE values were calculated to determine the color differences between the groups and the control and then were compared with a perceptional threshold (ΔE = 2.6). Repeated measures ANOVA and Bonferroni tests were used for data analysis ( P < 0.05). The mean and standard deviation of ΔE values for A1, A2, A3, B2, C2, and D3 groups were 6.78 ± 1.59, 8.13 ± 1.66, 9.81 ± 2.64, 9.61 ± 1.38, 9.59 ± 2.63, and 8.13 ± 1.89, respectively. A significant difference was found among the groups in the ΔE values ( P = 0.006). The ΔE values were more than the perceptional threshold in all the groups ( P < 0.0001). Within the limitations of this study, it can be concluded that the tested zirconia ceramic could not thoroughly mask different shades of the composite resin substrates. Moreover, color masking of zirconia depends on the shade of substrate.

  6. Vector scattering analysis of TPF coronagraph pupil masks

    NASA Astrophysics Data System (ADS)

    Ceperley, Daniel P.; Neureuther, Andrew R.; Lieber, Michael D.; Kasdin, N. Jeremy; Shih, Ta-Ming

    2004-10-01

    Rigorous finite-difference time-domain electromagnetic simulation is used to simulate the scattering from proto-typical pupil mask cross-section geometries and to quantify the differences from the normally assumed ideal on-off behavior. Shaped pupil plane masks are a promising technology for the TPF coronagraph mission. However the stringent requirements placed on the optics require that the detailed behavior of the edge-effects of these masks be examined carefully. End-to-end optical system simulation is essential and an important aspect is the polarization and cross-section dependent edge-effects which are the subject of this paper. Pupil plane masks are similar in many respects to photomasks used in the integrated circuit industry. Simulation capabilities such as the FDTD simulator, TEMPEST, developed for analyzing polarization and intensity imbalance effects in nonplanar phase-shifting photomasks, offer a leg-up in analyzing coronagraph masks. However, the accuracy in magnitude and phase required for modeling a chronograph system is extremely demanding and previously inconsequential errors may be of the same order of magnitude as the physical phenomena under study. In this paper, effects of thick masks, finite conductivity metals, and various cross-section geometries on the transmission of pupil-plane masks are illustrated. Undercutting the edge shape of Cr masks improves the effective opening width to within λ/5 of the actual opening but TE and TM polarizations require opposite compensations. The deviation from ideal is examined at the reference plane of the mask opening. Numerical errors in TEMPEST, such as numerical dispersion, perfectly matched layer reflections, and source haze are also discussed along with techniques for mitigating their impacts.

  7. [Recognition of visual objects under forward masking. Effects of cathegorial similarity of test and masking stimuli].

    PubMed

    Gerasimenko, N Iu; Slavutskaia, A V; Kalinin, S A; Kulikov, M A; Mikhaĭlova, E S

    2013-01-01

    In 38 healthy subjects accuracy and response time were examined during recognition of two categories of images--animals andnonliving objects--under forward masking. We revealed new data that masking effects depended of categorical similarity of target and masking stimuli. The recognition accuracy was the lowest and the response time was the most slow, when the target and masking stimuli belongs to the same category, that was combined with high dispersion of response times. The revealed effects were more clear in the task of animal recognition in comparison with the recognition of nonliving objects. We supposed that the revealed effects connected with interference between cortical representations of the target and masking stimuli and discussed our results in context of cortical interference and negative priming.

  8. Risk factors in facial hyperpigmentation in Maghrebian population - a case-control study.

    PubMed

    Benchikhi, H; Atide, N; Jroundi, I; Humbert, P; Lakhdar, H

    2012-10-01

    Triggering factors seem to be multiple in the pathogenesis of facial hyperpigmentation (FH), as dark skin types, pregnancy, sun exposure… The aim of this study was to investigate the risk factors for FH in Maghrebian population. Patients with FH were included in a case-controlled study. Following data were recorded: age, sex, parity, phototype, FH and hormonal-related history, endocrinological features, sunlight exposure, specific cultural behaviours, use of topic corticosteroids and sunscreens. One hundred women (mean age 29.5 ± 13.7 years) were included with 200 age-matched controls. Duration of FH was 32.9 ± 42.2 months. There was a statistically significant relation between FH and hirsutism (P = 0.009), troubles of menstruations (P = 0.008), but not with acne (P = 0.23) and contraceptive oral (P = 0.06) drugs or with history of thyroid disorders (P = 0.13). For cultural factors, there were a statistical significant relation with rubbing by flannel glove (P < 0.05), use of dark soap (P = 0.009) and traditional masks (P < 0.05) but both groups were used to go to hammam. A strong relation was observed between FH and use of topical corticosteroids: 40% in the FH group vs. 5% in the control group (P < 0.05). Both groups used to apply sunscreens: 70% in the FH group and 67% in the control group where as there were no differences in the two groups for sun exposure. No statistical differences were observed regarding to age, phototypes and grade of parity. Our study demonstrated a relation between FH and hyperestrogenemia, rubbing with a friction glove, use of moroccan traditional masks and application of topical steroids. The eviction of all these triggering factors could be an adjuvant recommendation in the assessment of FH. © 2012 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  9. Comparison of postoperative complication between Laryngeal Mask Airway and endotracheal tube during low-flow anesthesia with controlled ventilation

    PubMed Central

    Peirovifar, Ali; Eydi, Mahmood; Mirinejhad, Mir Mousa; Mahmoodpoor, Ata; Mohammadi, Afsaneh; EJ Golzari, Samad

    2013-01-01

    Objective: To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. Methodology: Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA). Cuff pressure was monitored during anesthesia. After high uptake period, fresh gas flow (FGF) was decreased to 1 lit/min and isoflurane set to 1%. Monitoring during anesthesia included non-invasive blood pressure, ECG, ETCO2 and pulse oximetry. System leakage (>100 ml/min), rebreathing and any attempt to increase FGF to overcome the leak were monitored during anesthesia. Later, patients were extubated and transferred to Post Anesthesia Care Unit (PACU). In PACU, the incidence of sore throat, cough, difficulty in swallowing and shivering was monitored for all patients. Results: Leakage was observed in two and three cases in ETT and LMA groups respectively (P>0.05). Postoperative cough, sore throat and difficulty in swallowing were significantly less in LMA than ETT group. No significant difference was observed regarding ETCo2 values between 2 groups. Conclusion: If careful measures regarding insertion techniques, correct LMA position and routine monitoring of LMA cuff pressure are taken, LMA can be used as a safe alternative with lower incidence of post operation complication compared with ETT during low-flow controlled anesthesia with modern anesthetic machines. PMID:24353586

  10. Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial.

    PubMed

    Bolinder, Jan; Antuna, Ramiro; Geelhoed-Duijvestijn, Petronella; Kröger, Jens; Weitgasser, Raimund

    2016-11-05

    Tight control of blood glucose in type 1 diabetes delays onset of macrovascular and microvascular diabetic complications; however, glucose levels need to be closely monitored to prevent hypoglycaemia. We aimed to assess whether a factory-calibrated, sensor-based, flash glucose-monitoring system compared with self-monitored glucose testing reduced exposure to hypoglycaemia in patients with type 1 diabetes. In this multicentre, prospective, non-masked, randomised controlled trial, we enrolled adult patients with well controlled type 1 diabetes (HbA 1c ≤58 mmol/mol [7·5%]) from 23 European diabetes centres. After 2 weeks of all participants wearing the blinded sensor, those with readings for at least 50% of the period were randomly assigned (1:1) to flash sensor-based glucose monitoring (intervention group) or to self-monitoring of blood glucose with capillary strips (control group). Randomisation was done centrally using the biased-coin minimisation method dependent on study centre and type of insulin administration. Participants, investigators, and study staff were not masked to group allocation. The primary outcome was change in time in hypoglycaemia (<3·9 mmol/L [70 mg/dL]) between baseline and 6 months in the full analysis set (all participants randomised; excluding those who had a positive pregnancy test during the study). This trial was registered with ClinicalTrials.gov, number NCT02232698. Between Sept 4, 2014, and Feb 12, 2015, we enrolled 328 participants. After the screening and baseline phase, 120 participants were randomly assigned to the intervention group and 121 to the control group, with outcomes being evaluated in 119 and 120, respectively. Mean time in hypoglycaemia changed from 3·38 h/day at baseline to 2·03 h/day at 6 months (baseline adjusted mean change -1·39) in the intervention group, and from 3·44 h/day to 3·27 h/day in the control group (-0·14); with the between-group difference of -1·24 (SE 0·239; p<0·0001), equating to a 38

  11. Vibration-Assisted Femtosecond Laser Drilling with Controllable Taper Angles for AMOLED Fine Metal Mask Fabrication.

    PubMed

    Choi, Wonsuk; Kim, Hoon Young; Jeon, Jin Woo; Chang, Won Seok; Cho, Sung-Hak

    2017-02-21

    This study investigates the effect of focal plane variation using vibration in a femtosecond laser hole drilling process on Invar alloy fabrication quality for the production of fine metal masks (FMMs). FMMs are used in the red, green, blue (RGB) evaporation process in Active Matrix Organic Light-Emitting Diode (AMOLED) manufacturing. The taper angle of the hole is adjusted by attaching the objective lens to a micro-vibrator and continuously changing the focal plane position. Eight laser pulses were used to examine how the hole characteristics vary with the first focal plane's position, where the first pulse is focused at an initial position and the focal planes of subsequent pulses move downward. The results showed that the hole taper angle can be controlled by varying the amplitude of the continuously operating vibrator during femtosecond laser hole machining. The taper angles were changed between 31.8° and 43.9° by adjusting the vibrator amplitude at a frequency of 100 Hz. Femtosecond laser hole drilling with controllable taper angles is expected to be used in the precision micro-machining of various smart devices.

  12. Taming the Wildness of "Trojan-Horse" Peptides by Charge-Guided Masking and Protease-Triggered Demasking for the Controlled Delivery of Antitumor Agents.

    PubMed

    Shi, Nian-Qiu; Qi, Xian-Rong

    2017-03-29

    Cell-penetrating peptide (CPP), also called "Trojan Horse" peptide, has become a successful approach to deliver various payloads into cells for achieving the intracellular access. However, the "Trojan Horse" peptide is too wild, not just to "Troy", but rather widely distributed in the body. Thus, there is an urgent need to tame the wildness of "Trojan Horse" peptide for targeted delivery of antineoplastic agents to the tumor site. To achieve this goal, we exploit a masked CPP-doxorubicin conjugate platform for targeted delivery of chemotherapeutic drugs using charge-guided masking and protease-triggered demasking strategies. In this platform, the cell-penetrating function of the positively CPP (d-form nonaarginine) is abrogated by a negatively shielding peptide (masked CPP), and between them is a cleavable substrate peptide by the protease (MMP-2/9). Protease-triggered demasking would occur when the masked CPP reached the MMP-2/9-riched tumor. The CPP-doxorubicin conjugate (CPP-Dox) and the masked CPP-Dox conjugate (mCPP-Dox) were used as models for the evaluation of masking and demasking processes. It was found that exogenous MMP-2/9 could effectively trigger the reversion of CPP-cargo in this conjugate, and this trigger adhered to the Michaelis-Menten kinetics profile. This conjugate was sensitive to the trigger of endogenous MMP-2/9 and could induce enhanced cytotoxicity toward MMP-2/9-rich tumor cells. In vivo antitumor efficacy revealed that this masked conjugate had considerable antitumor activity and could inhibit the tumor growth at a higher level relative to CPP-cargo. Low toxicity in vivo showed the noticeably decreased wildness of this conjugate toward normal tissues and more controllable entry of antitumor agents into "Troy". On the basis of analyses in vitro and in vivo, this mCPP-cargo conjugate delivery system held an improved selectivity toward MMP-2/9-rich tumors and would be a promising strategy for tumor-targeted treatment.

  13. Simulation based mask defect repair verification and disposition

    NASA Astrophysics Data System (ADS)

    Guo, Eric; Zhao, Shirley; Zhang, Skin; Qian, Sandy; Cheng, Guojie; Vikram, Abhishek; Li, Ling; Chen, Ye; Hsiang, Chingyun; Zhang, Gary; Su, Bo

    2009-10-01

    As the industry moves towards sub-65nm technology nodes, the mask inspection, with increased sensitivity and shrinking critical defect size, catches more and more nuisance and false defects. Increased defect counts pose great challenges in the post inspection defect classification and disposition: which defect is real defect, and among the real defects, which defect should be repaired and how to verify the post-repair defects. In this paper, we address the challenges in mask defect verification and disposition, in particular, in post repair defect verification by an efficient methodology, using SEM mask defect images, and optical inspection mask defects images (only for verification of phase and transmission related defects). We will demonstrate the flow using programmed mask defects in sub-65nm technology node design. In total 20 types of defects were designed including defects found in typical real circuit environments with 30 different sizes designed for each type. The SEM image was taken for each programmed defect after the test mask was made. Selected defects were repaired and SEM images from the test mask were taken again. Wafers were printed with the test mask before and after repair as defect printability references. A software tool SMDD-Simulation based Mask Defect Disposition-has been used in this study. The software is used to extract edges from the mask SEM images and convert them into polygons to save in GDSII format. Then, the converted polygons from the SEM images were filled with the correct tone to form mask patterns and were merged back into the original GDSII design file. This merge is for the purpose of contour simulation-since normally the SEM images cover only small area (~1 μm) and accurate simulation requires including larger area of optical proximity effect. With lithography process model, the resist contour of area of interest (AOI-the area surrounding a mask defect) can be simulated. If such complicated model is not available, a simple

  14. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis

    PubMed Central

    Smith, Jeffrey D.; MacDougall, Colin C.; Johnstone, Jennie; Copes, Ray A.; Schwartz, Brian; Garber, Gary E.

    2016-01-01

    Background: Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. Methods: We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case–control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. Results: We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case–control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64–1.24; cohort study: OR 0.43, 95% CI 0.03–6.41; case–control studies: OR 0.91, 95% CI 0.25–3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19–1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57–1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions

  15. Effectiveness of N95 respirators versus surgical masks in protecting health care workers from acute respiratory infection: a systematic review and meta-analysis.

    PubMed

    Smith, Jeffrey D; MacDougall, Colin C; Johnstone, Jennie; Copes, Ray A; Schwartz, Brian; Garber, Gary E

    2016-05-17

    Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case-control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case-control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64-1.24; cohort study: OR 0.43, 95% CI 0.03-6.41; case-control studies: OR 0.91, 95% CI 0.25-3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19-1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57-1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Although N95

  16. Bitter taste masking of enzyme-treated soy protein in water and bread.

    PubMed

    Bertelsen, Anne S; Laursen, Anne; Knudsen, Tine A; Møller, Stine; Kidmose, Ulla

    2018-08-01

    Bioactive protein hydrolysates are often very bitter. To overcome this challenge, xylitol, sucrose, α-cyclodextrin, maltodextrin and combinations of these were tested systematically as bitter-masking agents of an enzyme-treated soy protein in an aqueous model and in a bread model. Sensory descriptive analysis was used to reveal the bitter-masking effect of the taste-masking blends on the enzyme-treated soy protein. In water, xylitol, sucrose and maltodextrin reduced bitterness significantly, whereas α-cyclodextrin did not. No significant difference was observed in bitterness reduction between xylitol and sucrose. Both reduced bitterness significantly more than maltodextrin. No interactions between the taste-masking agents affecting bitterness reduction were found. Clearer bitter-masking effects were seen in the aqueous model compared with the bread model. The bitter-masking effects of α-cyclodextrin and maltodextrin were similar between water and bread. The effect of xylitol and sucrose on bitterness suppression varied between the systems. In water, bitterness was negatively correlated with sweetness. In bread, bitterness was negatively correlated with freshness, and maltodextrin significantly reduced bitterness of the enzyme-treated soy protein and increased freshness. Bitter-masking effects were generally more discernible in the aqueous model compared with the bread model. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  17. Non-invasive primate head restraint using thermoplastic masks.

    PubMed

    Drucker, Caroline B; Carlson, Monica L; Toda, Koji; DeWind, Nicholas K; Platt, Michael L

    2015-09-30

    The success of many neuroscientific studies depends upon adequate head fixation of awake, behaving animals. Typically, this is achieved by surgically affixing a head-restraint prosthesis to the skull. Here we report the use of thermoplastic masks to non-invasively restrain monkeys' heads. Mesh thermoplastic sheets become pliable when heated and can then be molded to an individual monkey's head. After cooling, the custom mask retains this shape indefinitely for day-to-day use. We successfully trained rhesus macaques (Macaca mulatta) to perform cognitive tasks while wearing thermoplastic masks. Using these masks, we achieved a level of head stability sufficient for high-resolution eye-tracking and intracranial electrophysiology. Compared with traditional head-posts, we find that thermoplastic masks perform at least as well during infrared eye-tracking and single-neuron recordings, allow for clearer magnetic resonance image acquisition, enable freer placement of a transcranial magnetic stimulation coil, and impose lower financial and time costs on the lab. We conclude that thermoplastic masks are a viable non-invasive form of primate head restraint that enable a wide range of neuroscientific experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Non-invasive primate head restraint using thermoplastic masks

    PubMed Central

    Drucker, Caroline B.; Carlson, Monica L.; Toda, Koji; DeWind, Nicholas K.; Platt, Michael L.

    2015-01-01

    Background The success of many neuroscientific studies depends upon adequate head fixation of awake, behaving animals. Typically, this is achieved by surgically affixing a head-restraint prosthesis to the skull. New Method Here we report the use of thermoplastic masks to non-invasively restrain monkeys’ heads. Mesh thermoplastic sheets become pliable when heated and can then be molded to an individual monkey’s head. After cooling, the custom mask retains this shape indefinitely for day-to-day use. Results We successfully trained rhesus macaques (Macaca mulatta) to perform cognitive tasks while wearing thermoplastic masks. Using these masks, we achieved a level of head stability sufficient for high-resolution eye-tracking and intracranial electrophysiology. Comparison with Existing Method Compared with traditional head-posts, we find that thermoplastic masks perform at least as well during infrared eye-tracking and single-neuron recordings, allow for clearer magnetic resonance image acquisition, enable freer placement of a transcranial magnetic stimulation coil, and impose lower financial and time costs on the lab. Conclusions We conclude that thermoplastic masks are a viable non-invasive form of primate head restraint that enable a wide range of neuroscientific experiments. PMID:26112334

  19. The mysterious noh mask: contribution of multiple facial parts to the recognition of emotional expressions.

    PubMed

    Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo; Kawai, Nobuyuki

    2012-01-01

    A Noh mask worn by expert actors when performing on a Japanese traditional Noh drama is suggested to convey countless different facial expressions according to different angles of head/body orientation. The present study addressed the question of how different facial parts of a Noh mask, including the eyebrows, the eyes, and the mouth, may contribute to different emotional expressions. Both experimental situations of active creation and passive recognition of emotional facial expressions were introduced. In Experiment 1, participants either created happy or sad facial expressions, or imitated a face that looked up or down, by actively changing each facial part of a Noh mask image presented on a computer screen. For an upward tilted mask, the eyebrows and the mouth shared common features with sad expressions, whereas the eyes with happy expressions. This contingency tended to be reversed for a downward tilted mask. Experiment 2 further examined which facial parts of a Noh mask are crucial in determining emotional expressions. Participants were exposed to the synthesized Noh mask images with different facial parts expressing different emotions. Results clearly revealed that participants primarily used the shape of the mouth in judging emotions. The facial images having the mouth of an upward/downward tilted Noh mask strongly tended to be evaluated as sad/happy, respectively. The results suggest that Noh masks express chimeric emotional patterns, with different facial parts conveying different emotions This appears consistent with the principles of Noh which highly appreciate subtle and composite emotional expressions, as well as with the mysterious facial expressions observed in Western art. It was further demonstrated that the mouth serves as a diagnostic feature in characterizing the emotional expressions. This indicates the superiority of biologically-driven factors over the traditionally formulated performing styles when evaluating the emotions of the Noh masks.

  20. The Mysterious Noh Mask: Contribution of Multiple Facial Parts to the Recognition of Emotional Expressions

    PubMed Central

    Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo; Kawai, Nobuyuki

    2012-01-01

    Background A Noh mask worn by expert actors when performing on a Japanese traditional Noh drama is suggested to convey countless different facial expressions according to different angles of head/body orientation. The present study addressed the question of how different facial parts of a Noh mask, including the eyebrows, the eyes, and the mouth, may contribute to different emotional expressions. Both experimental situations of active creation and passive recognition of emotional facial expressions were introduced. Methodology/Principal Findings In Experiment 1, participants either created happy or sad facial expressions, or imitated a face that looked up or down, by actively changing each facial part of a Noh mask image presented on a computer screen. For an upward tilted mask, the eyebrows and the mouth shared common features with sad expressions, whereas the eyes with happy expressions. This contingency tended to be reversed for a downward tilted mask. Experiment 2 further examined which facial parts of a Noh mask are crucial in determining emotional expressions. Participants were exposed to the synthesized Noh mask images with different facial parts expressing different emotions. Results clearly revealed that participants primarily used the shape of the mouth in judging emotions. The facial images having the mouth of an upward/downward tilted Noh mask strongly tended to be evaluated as sad/happy, respectively. Conclusions/Significance The results suggest that Noh masks express chimeric emotional patterns, with different facial parts conveying different emotions This appears consistent with the principles of Noh which highly appreciate subtle and composite emotional expressions, as well as with the mysterious facial expressions observed in Western art. It was further demonstrated that the mouth serves as a diagnostic feature in characterizing the emotional expressions. This indicates the superiority of biologically-driven factors over the traditionally

  1. Effect of Three Different Core Materials on Masking Ability of a Zirconia Ceramic.

    PubMed

    Tabatabaian, Farhad; Masoomi, Faeze; Namdari, Mahshid; Mahshid, Minoo

    2016-09-01

    Masking ability of a restorative material plays a role in hiding colored substructures; however, the masking ability of zirconia ceramic (ZRC) has not yet been clearly understood in zirconia-based restorations. This study evaluated the effect of three different core materials on masking ability of a ZRC. Ten zirconia disc samples, 0.5mm in thickness and 10mm in diameter, were fabricated. A white (W) substrate (control) and three substrates of nickel-chromium alloy (NCA), non-precious gold alloy (NPGA), and ZRC were prepared. The zirconia discs were placed on the four types of substrates for spectrophotometry. The L*, a*, and b* values of the specimens were measured by a spectrophotometer and color change (ΔE) values were calculated to determine color differences between the test and control groups and were then compared with the perceptual threshold. Randomized block ANOVA and Bonferroni test analyzed the data. A significance level of 0.05 was considered. The mean and standard deviation values of ΔE for NCA, NPGA, and ZRC groups were 10.26±2.43, 9.45±1.74, and 6.70±1.91 units, respectively. Significant differences were found in the ΔE values between ZRC and the other two experimental groups (NCA and NPGA; P<0.0001 and P=0.001, respectively). The ΔE values for the groups were more than the predetermined perceptual threshold. Within the limitations of this study, it was concluded that the tested ZRC could not well mask the examined core materials.

  2. Effects of trypan blue on corneal endothelium and anterior lens capsule in albino wistar rats: An investigator-masked, controlled, two-period, experimental study

    PubMed Central

    Ari, Seyhmus; Çaça, Ihsan; Ünlü, Kaan; Nergiz, Yusuf; Aksit, Ihsan

    2006-01-01

    Background: The development of continuous curvilinear capsulorrhexis (CCC) has contributed significantly to the tolerability and effectiveness of cataract extraction and intraocular lens implantation. Staining of the anterior capsule has become a popular method of increasing visibility when performing CCC. Objective: The aim of this study was to determine, using scanning electron microscopy (SEM) and transmission electron microscopy (TEM), the highest concentrations of trypan blue dye that would not cause long-term toxicity after injection into the anterior chamber of rat eyes. Methods: The eyes of healthy female albino Wistar rats were used in this investigator-masked, controlled, 2-period, experimental study conducted over 12 weeks at the Dicle University Experimental Animal Laboratory, Diyarbakir, Turkey. The rats were randomly divided into 5 groups of 4 using a random-number table. Each rat was administered a 0.05-mL injection of trypan blue into the right eye in 1 of the following concentrations: 0.4%, 0.2%, 0.1%, 0.05%, or 0.025%. A 0.05-mL pH-balanced saline solution was injected into the left eye of each rat to act as a control. At 1 day after injection and 4 weeks after injection (early period), 1 rat from each concentration group was euthanized and their eyes were enucleated. At 12 weeks after injection (late period) the remaining 2 rats from each group were euthanized and their eyes were enucleated. Corneal endothelial cells and the anterior lens capsule of the enucleated eyes were analyzed using SEM and TEM, and the results were compared with those of the control group. In the TEM analysis, the primary end point was the histopathologic changes in the cellular organelles when compared with those in the control group. In the SEM analysis, the primary end point was changes in cell shape, intracellular junctions, and density of the microvilli when compared with those in the control group. Results: Forty eyes from 20 albino Wistar rats (mean [SD] age, 8.2 [1

  3. Masking disrupts reentrant processing in human visual cortex.

    PubMed

    Fahrenfort, J J; Scholte, H S; Lamme, V A F

    2007-09-01

    In masking, a stimulus is rendered invisible through the presentation of a second stimulus shortly after the first. Over the years, authors have typically explained masking by postulating some early disruption process. In these feedforward-type explanations, the mask somehow "catches up" with the target stimulus, disrupting its processing either through lateral or interchannel inhibition. However, studies from recent years indicate that visual perception--and most notably visual awareness itself--may depend strongly on cortico-cortical feedback connections from higher to lower visual areas. This has led some researchers to propose that masking derives its effectiveness from selectively interrupting these reentrant processes. In this experiment, we used electroencephalogram measurements to determine what happens in the human visual cortex during detection of a texture-defined square under nonmasked (seen) and masked (unseen) conditions. Electro-encephalogram derivatives that are typically associated with reentrant processing turn out to be absent in the masked condition. Moreover, extrastriate visual areas are still activated early on by both seen and unseen stimuli, as shown by scalp surface Laplacian current source-density maps. This conclusively shows that feedforward processing is preserved, even when subject performance is at chance as determined by objective measures. From these results, we conclude that masking derives its effectiveness, at least partly, from disrupting reentrant processing, thereby interfering with the neural mechanisms of figure-ground segmentation and visual awareness itself.

  4. Auditory Time-Frequency Masking for Spectrally and Temporally Maximally-Compact Stimuli.

    PubMed

    Necciari, Thibaud; Laback, Bernhard; Savel, Sophie; Ystad, Sølvi; Balazs, Peter; Meunier, Sabine; Kronland-Martinet, Richard

    2016-01-01

    Many audio applications perform perception-based time-frequency (TF) analysis by decomposing sounds into a set of functions with good TF localization (i.e. with a small essential support in the TF domain) using TF transforms and applying psychoacoustic models of auditory masking to the transform coefficients. To accurately predict masking interactions between coefficients, the TF properties of the model should match those of the transform. This involves having masking data for stimuli with good TF localization. However, little is known about TF masking for mathematically well-localized signals. Most existing masking studies used stimuli that are broad in time and/or frequency and few studies involved TF conditions. Consequently, the present study had two goals. The first was to collect TF masking data for well-localized stimuli in humans. Masker and target were 10-ms Gaussian-shaped sinusoids with a bandwidth of approximately one critical band. The overall pattern of results is qualitatively similar to existing data for long maskers. To facilitate implementation in audio processing algorithms, a dataset provides the measured TF masking function. The second goal was to assess the potential effect of auditory efferents on TF masking using a modeling approach. The temporal window model of masking was used to predict present and existing data in two configurations: (1) with standard model parameters (i.e. without efferents), (2) with cochlear gain reduction to simulate the activation of efferents. The ability of the model to predict the present data was quite good with the standard configuration but highly degraded with gain reduction. Conversely, the ability of the model to predict existing data for long maskers was better with than without gain reduction. Overall, the model predictions suggest that TF masking can be affected by efferent (or other) effects that reduce cochlear gain. Such effects were avoided in the experiment of this study by using maximally

  5. Dissociable brain mechanisms underlying the conscious and unconscious control of behavior.

    PubMed

    van Gaal, Simon; Lamme, Victor A F; Fahrenfort, Johannes J; Ridderinkhof, K Richard

    2011-01-01

    Cognitive control allows humans to overrule and inhibit habitual responses to optimize performance in challenging situations. Contradicting traditional views, recent studies suggest that cognitive control processes can be initiated unconsciously. To further capture the relation between consciousness and cognitive control, we studied the dynamics of inhibitory control processes when triggered consciously versus unconsciously in a modified version of the stop task. Attempts to inhibit an imminent response were often successful after unmasked (visible) stop signals. Masked (invisible) stop signals rarely succeeded in instigating overt inhibition but did trigger slowing down of response times. Masked stop signals elicited a sequence of distinct ERP components that were also observed on unmasked stop signals. The N2 component correlated with the efficiency of inhibitory control when elicited by unmasked stop signals and with the magnitude of slowdown when elicited by masked stop signals. Thus, the N2 likely reflects the initiation of inhibitory control, irrespective of conscious awareness. The P3 component was much reduced in amplitude and duration on masked versus unmasked stop trials. These patterns of differences and similarities between conscious and unconscious cognitive control processes are discussed in a framework that differentiates between feedforward and feedback connections in yielding conscious experience.

  6. The Sensitivity of Coded Mask Telescopes

    NASA Technical Reports Server (NTRS)

    Skinner, Gerald K.

    2008-01-01

    Simple formulae are often used to estimate the sensitivity of coded mask X-ray or gamma-ray telescopes, but t,hese are strictly only applicable if a number of basic assumptions are met. Complications arise, for example, if a grid structure is used to support the mask elements, if the detector spatial resolution is not good enough to completely resolve all the detail in the shadow of the mask or if any of a number of other simplifying conditions are not fulfilled. We derive more general expressions for the Poisson-noise-limited sensitivity of astronomical telescopes using the coded mask technique, noting explicitly in what circumstances they are applicable. The emphasis is on using nomenclature and techniques that result in simple and revealing results. Where no convenient expression is available a procedure is given which allows the calculation of the sensitivity. We consider certain aspects of the optimisation of the design of a coded mask telescope and show that when the detector spatial resolution and the mask to detector separation are fixed, the best source location accuracy is obtained when the mask elements are equal in size to the detector pixels.

  7. Testing the efficacy of homemade masks: would they protect in an influenza pandemic?

    PubMed

    Davies, Anna; Thompson, Katy-Anne; Giri, Karthika; Kafatos, George; Walker, Jimmy; Bennett, Allan

    2013-08-01

    This study examined homemade masks as an alternative to commercial face masks. Several household materials were evaluated for the capacity to block bacterial and viral aerosols. Twenty-one healthy volunteers made their own face masks from cotton t-shirts; the masks were then tested for fit. The number of microorganisms isolated from coughs of healthy volunteers wearing their homemade mask, a surgical mask, or no mask was compared using several air-sampling techniques. The median-fit factor of the homemade masks was one-half that of the surgical masks. Both masks significantly reduced the number of microorganisms expelled by volunteers, although the surgical mask was 3 times more effective in blocking transmission than the homemade mask. Our findings suggest that a homemade mask should only be considered as a last resort to prevent droplet transmission from infected individuals, but it would be better than no protection.

  8. Mask data processing in the era of multibeam writers

    NASA Astrophysics Data System (ADS)

    Abboud, Frank E.; Asturias, Michael; Chandramouli, Maesh; Tezuka, Yoshihiro

    2014-10-01

    Mask writers' architectures have evolved through the years in response to ever tightening requirements for better resolution, tighter feature placement, improved CD control, and tolerable write time. The unprecedented extension of optical lithography and the myriad of Resolution Enhancement Techniques have tasked current mask writers with ever increasing shot count and higher dose, and therefore, increasing write time. Once again, we see the need for a transition to a new type of mask writer based on massively parallel architecture. These platforms offer a step function improvement in both dose and the ability to process massive amounts of data. The higher dose and almost unlimited appetite for edge corrections open new windows of opportunity to further push the envelope. These architectures are also naturally capable of producing curvilinear shapes, making the need to approximate a curve with multiple Manhattan shapes unnecessary.

  9. A Prospective, Randomized, Masked, Placebo-Controlled Multisite Clinical Study of Grapiprant, an EP4 Prostaglandin Receptor Antagonist (PRA), in Dogs with Osteoarthritis.

    PubMed

    Rausch-Derra, L; Huebner, M; Wofford, J; Rhodes, L

    2016-05-01

    This study evaluated the effectiveness and safety of grapiprant for treatment of pain in dogs with osteoarthritis (OA). Grapiprant will relieve pain as measured by the owner's and veterinarian's evaluation of pain in dogs with OA. Another objective was evaluation of the safety of grapiprant. Two hundred and eighty-five client-owned dogs with OA were enrolled and treated with grapiprant or placebo with 262 cases (N = 131 in each group) evaluable for the effectiveness analysis. In this prospective, randomized, masked, placebo-controlled study dogs were treated daily with grapiprant (2 mg/kg) per OS or placebo. Owners completed an evaluation using the Canine Brief Pain Inventory (CBPI) on days 0, 7, 14, 21, and 28. Success was defined as improvement in the CBPI. Veterinary assessments were made on screening and days 14 and 28. Safety was evaluated by physical examination, evaluation of clinical pathology results, and owner observations. Grapiprant treatment improved pain compared to placebo on day 28 (48.1 and 31.3% treatment successes respectively; P = .0315). The pain interference score (PIS) and pain severity score (PSS) improved in the grapiprant group compared to placebo (P = .0029 and 0.0022, respectively). Veterinary assessments were significantly better in the grapiprant-treated dogs (P = .0086). Grapiprant generally was well tolerated, but a higher percentage of treated dogs (17.02%) had occasional vomiting as compared to the placebo group (6.25%). Grapiprant is an effective treatment for alleviation of pain in dogs with OA, and represents a modality of treatment that may be better tolerated than current options. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  10. Comparing masked target transform volume (MTTV) clutter metric to human observer evaluation of visual clutter

    NASA Astrophysics Data System (ADS)

    Camp, H. A.; Moyer, Steven; Moore, Richard K.

    2010-04-01

    The Night Vision and Electronic Sensors Directorate's current time-limited search (TLS) model, which makes use of the targeting task performance (TTP) metric to describe image quality, does not explicitly account for the effects of visual clutter on observer performance. The TLS model is currently based on empirical fits to describe human performance for a time of day, spectrum and environment. Incorporating a clutter metric into the TLS model may reduce the number of these empirical fits needed. The masked target transform volume (MTTV) clutter metric has been previously presented and compared to other clutter metrics. Using real infrared imagery of rural images with varying levels of clutter, NVESD is currently evaluating the appropriateness of the MTTV metric. NVESD had twenty subject matter experts (SME) rank the amount of clutter in each scene in a series of pair-wise comparisons. MTTV metric values were calculated and then compared to the SME observers rankings. The MTTV metric ranked the clutter in a similar manner to the SME evaluation, suggesting that the MTTV metric may emulate SME response. This paper is a first step in quantifying clutter and measuring the agreement to subjective human evaluation.

  11. Quantification of mammographic masking risk with volumetric breast density maps: how to select women for supplemental screening

    NASA Astrophysics Data System (ADS)

    Holland, Katharina; van Gils, Carla H.; Wanders, Johanna OP; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    The sensitivity of mammograms is low for women with dense breasts, since cancers may be masked by dense tissue. In this study, we investigated methods to identify women with density patterns associated with a high masking risk. Risk measures are derived from volumetric breast density maps. We used the last negative screening mammograms of 93 women who subsequently presented with an interval cancer (IC), and, as controls, 930 randomly selected normal screening exams from women without cancer. Volumetric breast density maps were computed from the mammograms, which provide the dense tissue thickness at each location. These were used to compute absolute and percentage glandular tissue volume. We modeled the masking risk for each pixel location using the absolute and percentage dense tissue thickness and we investigated the effect of taking the cancer location probability distribution (CLPD) into account. For each method, we selected cases with the highest masking measure (by thresholding) and computed the fraction of ICs as a function of the fraction of controls selected. The latter can be interpreted as the negative supplemental screening rate (NSSR). Between the models, when incorporating CLPD, no significant differences were found. In general, the methods performed better when CLPD was included. At higher NSSRs some of the investigated masking measures had a significantly higher performance than volumetric breast density. These measures may therefore serve as an alternative to identify women with a high risk for a masked cancer.

  12. 21 CFR 868.5570 - Nonrebreathing mask.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonrebreathing mask. 868.5570 Section 868.5570...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5570 Nonrebreathing mask. (a) Identification. A nonrebreathing mask is a device fitting over a patient's face to administer oxygen. It utilizes...

  13. 37 CFR 211.3 - Mask work fees.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Mask work fees. 211.3 Section... PROCEDURES MASK WORK PROTECTION § 211.3 Mask work fees. (a) Section 201.3 of this chapter prescribes the fees or charges established by the Register of Copyrights for services relating to mask works. (b) Section...

  14. 37 CFR 211.3 - Mask work fees.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2011-07-01 2011-07-01 false Mask work fees. 211.3 Section... PROCEDURES MASK WORK PROTECTION § 211.3 Mask work fees. (a) Section 201.3 of this chapter prescribes the fees or charges established by the Register of Copyrights for services relating to mask works. (b) Section...

  15. Are visual cue masking and removal techniques equivalent for studying perceptual skills in sport?

    PubMed

    Mecheri, Sami; Gillet, Eric; Thouvarecq, Regis; Leroy, David

    2011-01-01

    The spatial-occlusion paradigm makes use of two techniques (masking and removing visual cues) to provide information about the anticipatory cues used by viewers. The visual scene resulting from the removal technique appears to be incongruous, but the assumed equivalence of these two techniques is spreading. The present study was designed to address this issue by combining eye-movement recording with the two types of occlusion (removal versus masking) in a tennis serve-return task. Response accuracy and decision onsets were analysed. The results indicated that subjects had longer reaction times under the removal condition, with an identical proportion of correct responses. Also, the removal technique caused the subjects to rely on atypical search patterns. Our findings suggest that, when the removal technique was used, viewers were unable to systematically count on stored memories to help them accomplish the interception task. The persistent failure to question some of the assumptions about the removal technique in applied visual research is highlighted, and suggestions for continued use of the masking technique are advanced.

  16. Automated imprint mask cleaning for step-and-flash imprint lithography

    NASA Astrophysics Data System (ADS)

    Singh, Sherjang; Chen, Ssuwei; Selinidis, Kosta; Fletcher, Brian; McMackin, Ian; Thompson, Ecron; Resnick, Douglas J.; Dress, Peter; Dietze, Uwe

    2009-03-01

    Step-and-Flash Imprint Lithography (S-FIL) is a promising lithography strategy for semiconductor manufacturing at device nodes below 32nm. The S-FIL 1:1 pattern transfer technology utilizes a field-by-field ink jet dispense of a low viscosity liquid resist to fill the relief pattern of the device layer etched into the glass mask. Compared to other sub 40nm CD lithography methods, the resulting high resolution, high throughput through clustering, 3D patterning capability, low process complexity, and low cost of ownership (CoO) of S-FIL makes it a widely accepted technology for patterned media as well as a promising mainstream option for future CMOS applications. Preservation of mask cleanliness is essential to avoid risk of repeated printing of defects. The development of mask cleaning processes capable of removing particles adhered to the mask surface without damaging the mask is critical to meet high volume manufacturing requirements. In this paper we have presented various methods of residual (cross-linked) resist removal and final imprint mask cleaning demonstrated on the HamaTech MaskTrack automated mask cleaning system. Conventional and non-conventional (acid free) methods of particle removal have been compared and the effect of mask cleaning on pattern damage and CD integrity is also studied.

  17. Using automated texture features to determine the probability for masking of a tumor on mammography, but not ultrasound.

    PubMed

    Häberle, Lothar; Hack, Carolin C; Heusinger, Katharina; Wagner, Florian; Jud, Sebastian M; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger; Wittenberg, Thomas; Fasching, Peter A

    2017-08-30

    Tumors in radiologically dense breast were overlooked on mammograms more often than tumors in low-density breasts. A fast reproducible and automated method of assessing percentage mammographic density (PMD) would be desirable to support decisions whether ultrasonography should be provided for women in addition to mammography in diagnostic mammography units. PMD assessment has still not been included in clinical routine work, as there are issues of interobserver variability and the procedure is quite time consuming. This study investigated whether fully automatically generated texture features of mammograms can replace time-consuming semi-automatic PMD assessment to predict a patient's risk of having an invasive breast tumor that is visible on ultrasound but masked on mammography (mammography failure). This observational study included 1334 women with invasive breast cancer treated at a hospital-based diagnostic mammography unit. Ultrasound was available for the entire cohort as part of routine diagnosis. Computer-based threshold PMD assessments ("observed PMD") were carried out and 363 texture features were obtained from each mammogram. Several variable selection and regression techniques (univariate selection, lasso, boosting, random forest) were applied to predict PMD from the texture features. The predicted PMD values were each used as new predictor for masking in logistic regression models together with clinical predictors. These four logistic regression models with predicted PMD were compared among themselves and with a logistic regression model with observed PMD. The most accurate masking prediction was determined by cross-validation. About 120 of the 363 texture features were selected for predicting PMD. Density predictions with boosting were the best substitute for observed PMD to predict masking. Overall, the corresponding logistic regression model performed better (cross-validated AUC, 0.747) than one without mammographic density (0.734), but less well

  18. Culture, Gender and Health Care Stigma: Practitioners’ Response to Facial Masking Experienced by People with Parkinson’s Disease

    PubMed Central

    Tickle-Degnen, Linda; Zebrowitz, Leslie A.; Ma, Hui-ing

    2011-01-01

    Facial masking in Parkinson’s disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners’ responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners’ impressions of patient psychological attributes. Practitioners (N=284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners’ judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners’ judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners’ use of facial

  19. Simultaneous masking additivity for short Gaussian-shaped tones: spectral effects.

    PubMed

    Laback, Bernhard; Necciari, Thibaud; Balazs, Peter; Savel, Sophie; Ystad, Sølvi

    2013-08-01

    Laback et al. [(2011). J. Acoust. Soc. Am. 129, 888-897] investigated the additivity of nonsimultaneous masking using short Gaussian-shaped tones as maskers and target. The present study involved Gaussian stimuli to measure the additivity of simultaneous masking for combinations of up to four spectrally separated maskers. According to most basilar membrane measurements, the maskers should be processed linearly at the characteristic frequency (CF) of the target. Assuming also compression of the target, all masker combinations should produce excess masking (exceeding linear additivity). The results for a pair of maskers flanking the target indeed showed excess masking. The amount of excess masking could be predicted by a model assuming summation of masker-evoked excitations in intensity units at the target CF and compression of the target, using compressive input/output functions derived from the nonsimultaneous masking study. However, the combinations of lower-frequency maskers showed much less excess masking than predicted by the model. This cannot easily be attributed to factors like off-frequency listening, combination tone perception, or between-masker suppression. It was better predicted, however, by assuming weighted intensity summation of masker excitations. The optimum weights for the lower-frequency maskers were smaller than one, consistent with partial masker compression as indicated by recent psychoacoustic data.

  20. Orientation tuning of contrast masking caused by motion streaks.

    PubMed

    Apthorp, Deborah; Cass, John; Alais, David

    2010-08-01

    We investigated whether the oriented trails of blur left by fast-moving dots (i.e., "motion streaks") effectively mask grating targets. Using a classic overlay masking paradigm, we varied mask contrast and target orientation to reveal underlying tuning. Fast-moving Gaussian blob arrays elevated thresholds for detection of static gratings, both monoptically and dichoptically. Monoptic masking at high mask (i.e., streak) contrasts is tuned for orientation and exhibits a similar bandwidth to masking functions obtained with grating stimuli (∼30 degrees). Dichoptic masking fails to show reliable orientation-tuned masking, but dichoptic masks at very low contrast produce a narrowly tuned facilitation (∼17 degrees). For iso-oriented streak masks and grating targets, we also explored masking as a function of mask contrast. Interestingly, dichoptic masking shows a classic "dipper"-like TVC function, whereas monoptic masking shows no dip and a steeper "handle". There is a very strong unoriented component to the masking, which we attribute to transiently biased temporal frequency masking. Fourier analysis of "motion streak" images shows interesting differences between dichoptic and monoptic functions and the information in the stimulus. Our data add weight to the growing body of evidence that the oriented blur of motion streaks contributes to the processing of fast motion signals.

  1. Evidence for differential modulation of primary and nonprimary auditory cortex by forward masking in tinnitus.

    PubMed

    Roberts, Larry E; Bosnyak, Daniel J; Bruce, Ian C; Gander, Phillip E; Paul, Brandon T

    2015-09-01

    It has been proposed that tinnitus is generated by aberrant neural activity that develops among neurons in tonotopic of regions of primary auditory cortex (A1) affected by hearing loss, which is also the frequency region where tinnitus percepts localize (Eggermont and Roberts 2004; Roberts et al., 2010, 2013). These models suggest (1) that differences between tinnitus and control groups of similar age and audiometric function should depend on whether A1 is probed in tinnitus frequency region (TFR) or below it, and (2) that brain responses evoked from A1 should track changes in the tinnitus percept when residual inhibition (RI) is induced by forward masking. We tested these predictions by measuring (128-channel EEG) the sound-evoked 40-Hz auditory steady-state response (ASSR) known to localize tonotopically to neural sources in A1. For comparison the N1 transient response localizing to distributed neural sources in nonprimary cortex (A2) was also studied. When tested under baseline conditions where tinnitus subjects would have heard their tinnitus, ASSR responses were larger in a tinnitus group than in controls when evoked by 500 Hz probes while the reverse was true for tinnitus and control groups tested with 5 kHz probes, confirming frequency-dependent group differences in this measure. On subsequent trials where RI was induced by masking (narrow band noise centered at 5 kHz), ASSR amplitude increased in the tinnitus group probed at 5 kHz but not in the tinnitus group probed at 500 Hz. When collapsed into a single sample tinnitus subjects reporting comparatively greater RI depth and duration showed comparatively larger ASSR increases after masking regardless of probe frequency. Effects of masking on ASSR amplitude in the control groups were completely reversed from those in the tinnitus groups, with no change seen to 5 kHz probes but ASSR increases to 500 Hz probes even though the masking sound contained no energy at 500 Hz (an "off-frequency" masking

  2. Masking of sounds by a background noise – cochlear mechanical correlates

    PubMed Central

    Recio-Spinoso, Alberto; Cooper, Nigel P

    2013-01-01

    In the search for cochlear correlates of auditory masking by noise stimuli, we recorded basilar membrane (BM) vibrations evoked by either tone or click signals in the presence of varying levels of background noise. The BM vibrations were recorded from basal regions in healthy cochleae of anaesthetized chinchilla and gerbil. Non-linear interactions that could underpin various aspects of psychophysical masking data, including both compression and suppression at the BM level, were observed. The suppression effects, whereby the amplitude of the responses to each stimulus component could be reduced, depended on the relative intensities of the noise and the tones or clicks. Only stimulus components whose frequencies fell inside the non-linear region of the recording site, i.e. around its characteristic frequency (CF), were affected by presentation of the ‘suppressing’ stimulus (which could be either the tone or the noise). Mutual suppression, the simultaneous reduction of the responses to both tones and noise components, was observed under some conditions, but overall reductions of BM vibration were rarely observed. Moderate- to high-intensity tones suppressed BM responses to low-intensity Gaussian stimuli, including both broadband and narrowband noise. Suppression effects were larger for spectral components of the noise response that were closer to the CF. In this regime, the tone and noise stimuli became the suppressor and probe signals, respectively. This study provides the first detailed observations of cochlear mechanical correlates of the masking effects of noise. Mechanical detection thresholds for tone signals, which were arbitrarily defined using three criteria, are shown to increase in almost direct proportion to the noise level for low and moderately high noise levels, in a manner that resembles the findings of numerous psychophysical observations. PMID:23478137

  3. The Meaning behind the Mask. [Lesson Plan].

    ERIC Educational Resources Information Center

    National Endowment for the Humanities (NFAH), Washington, DC.

    In this lesson plan, students explore the cultural significance of masks. After exploring the world of African masks and storytelling, they create masks that tell stories of their own. In these six lessons, students first recall contexts in which masks are worn in the United States, and then discuss their use in stories. Students then investigate…

  4. 21 CFR 868.5590 - Scavenging mask.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scavenging mask. 868.5590 Section 868.5590 Food... DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5590 Scavenging mask. (a) Identification. A scavenging mask is a device positioned over a patient's nose to deliver anesthetic or analgesic gases to the...

  5. 21 CFR 868.5600 - Venturi mask.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Venturi mask. 868.5600 Section 868.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5600 Venturi mask. (a) Identification. A venturi mask is a...

  6. Inadequate face mask ventilation--clinical applications.

    PubMed

    Goranović, Tatjana; Milić, Morena; Holjevac, Jadranka Katancić; Maldini, Branka; Sakić, Katarina

    2010-09-01

    Face mask ventilation is a life saving technique. This article will review aetiology and patophysiological consequences of inadequate mask ventilation. The main focus will be on circulatory changes during induction of anesthesia, before and in a short period after intubation that could be attributed to inadequate mask ventilation in humans.

  7. Fabrication of coronagraph masks and laboratory scale star-shade masks: characteristics, defects, and performance

    NASA Astrophysics Data System (ADS)

    Balasubramanian, Kunjithapatham; Riggs, A. J. Eldorado; Cady, Eric; White, Victor; Yee, Karl; Wilson, Daniel; Echternach, Pierre; Muller, Richard; Mejia Prada, Camilo; Seo, Byoung-Joon; Shi, Fang; Ryan, Daniel; Fregoso, Santos; Metzman, Jacob; Wilson, Robert Casey

    2017-09-01

    NASA WFIRST mission has planned to include a coronagraph instrument to find and characterize exoplanets. Masks are needed to suppress the host star light to better than 10-8 - 10-9 level contrast over a broad bandwidth to enable the coronagraph mission objectives. Such masks for high contrast coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, etc. We present the technologies employed at JPL to produce these pupil plane and image plane coronagraph masks, and lab-scale external occulter masks, highlighting accomplishments from the high contrast imaging testbed (HCIT) at JPL and from the high contrast imaging lab (HCIL) at Princeton University. Inherent systematic and random errors in fabrication and their impact on coronagraph performance are discussed with model predictions and measurements.

  8. Film loss-free cleaning chemicals for EUV mask lifetime elongation developed through combinatorial chemical screening

    NASA Astrophysics Data System (ADS)

    Choi, Jaehyuck; Kim, Jinsu; Lowe, Jeff; Dattilo, Davide; Koh, Soowan; Choi, Jun Yeol; Dietze, Uwe; Shoki, Tsutomu; Kim, Byung Gook; Jeon, Chan-Uk

    2015-10-01

    EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. SPM (Sulfuric acid peroxide mixture) which has been extensively used for acid cleaning of photomask and wafer has serious drawback for EUV mask cleaning. It shows severe film loss of tantalum-based absorber layers and limited removal efficiency of EUV-generated carbon contaminants on EUV mask surface. Here, we introduce such novel cleaning chemicals developed for EUV mask as almost film loss free for various layers of the mask and superior carbon removal performance. Combinatorial chemical screening methods allowed us to screen several hundred combinations of various chemistries and additives under several different process conditions of temperature and time, eventually leading to development of the best chemistry selections for EUV mask cleaning. Recently, there have been many activities for the development of EUV pellicle, driven by ASML and core EUV scanner customer companies. It is still important to obtain film-loss free cleaning chemicals because cleaning cycle of EUV mask should be much faster than that of optic mask mainly due to EUV pellicle lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality changes and film losses during 50 cleaning cycles using new chemicals as well as particle and carbon contaminant removal characteristics. We have observed that the performance of new chemicals developed is superior to current SPM or relevant cleaning chemicals for EUV mask cleaning and EUV mask lifetime elongation.

  9. Attitudes of influenza‐vaccinated health care workers toward masks to prevent nosocomial transmission of influenza

    PubMed Central

    Brandt, Christian; Rabenau, Holger F.; Wicker, Sabine

    2010-01-01

    Please cite this paper as: Brandt et al. (2010) Attitudes of influenza‐vaccinated health care workers toward masks to prevent nosocomial transmission of influenza. . Influenza and Other Respiratory Viruses 5(1), 61–66. Background  Influenza viruses are highly contagious. Health care workers (HCWs) are at risk of occupational exposure to influenza and may transmit the infection to their patients and coworkers. Objectives  The aim of the study was to characterize the attitudes of HCWs regarding the use of surgical masks to prevent nosocomial influenza transmission. Furthermore, we assessed the informational needs of HCWs with regard to infection control measures. Methods  A survey was conducted among HCWs, using an anonymous questionnaire, at a German University Hospital during an influenza vaccination campaign. Results  Overall, 40·5% of the HCWs were vaccinated against seasonal influenza, and 35·2% were vaccinated against Influenza A/H1N1 (“swine flu”). In total, 1445 vaccinees completed the anonymous questionnaire. Of all respondents, 70·5% stated that the infection control recommendation “wearing a surgical” mask was appropriate to avoid influenza transmission. The percentage of HCWs who would like to have had more information about the infection control measures was 67·5%. Conclusions  Appropriate interventions ought to be taken to reduce the risk of exposure to influenza viruses among HCWs. Adherence to recommendations for the use of masks among HCWs needs to be evaluated. Further work is required to highlight the informational needs of HCWs to gain an appreciation of infection control measures. PMID:21138542

  10. Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production

    ERIC Educational Resources Information Center

    Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H.

    2015-01-01

    Purpose: This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method: The authors used noise masking to minimize auditory feedback during…

  11. Effects of temporal integration on the shape of visual backward masking functions.

    PubMed

    Francis, Gregory; Cho, Yang Seok

    2008-10-01

    Many studies of cognition and perception use a visual mask to explore the dynamics of information processing of a target. Especially important in these applications is the time between the target and mask stimuli. A plot of some measure of target visibility against stimulus onset asynchrony is called a masking function, which can sometimes be monotonic increasing but other times is U-shaped. Theories of backward masking have long hypothesized that temporal integration of the target and mask influences properties of masking but have not connected the influence of integration with the shape of the masking function. With two experiments that vary the spatial properties of the target and mask, the authors provide evidence that temporal integration of the stimuli plays a critical role in determining the shape of the masking function. The resulting data both challenge current theories of backward masking and indicate what changes to the theories are needed to account for the new data. The authors further discuss the implication of the findings for uses of backward masking to explore other aspects of cognition.

  12. Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects

    NASA Astrophysics Data System (ADS)

    Reddy, A. N. K.; Sagar, D. K.; Khonina, S. N.

    2017-12-01

    Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.

  13. Fast mask writers: technology options and considerations

    NASA Astrophysics Data System (ADS)

    Litt, Lloyd C.; Groves, Timothy; Hughes, Greg

    2011-04-01

    The semiconductor industry is under constant pressure to reduce production costs even as the complexity of technology increases. Lithography represents the most expensive process due to its high capital equipment costs and the implementation of low-k1 lithographic processes, which have added to the complexity of making masks because of the greater use of optical proximity correction, pixelated masks, and double or triple patterning. Each of these mask technologies allows the production of semiconductors at future nodes while extending the utility of current immersion tools. Low-k1 patterning complexity combined with increased data due to smaller feature sizes is driving extremely long mask write times. While a majority of the industry is willing to accept times of up to 24 hours, evidence suggests that the write times for many masks at the 22 nm node and beyond will be significantly longer. It has been estimated that funding on the order of 50M to 90M for non-recurring engineering (NRE) costs will be required to develop a multiple beam mask writer system, yet the business case to recover this kind of investment is not strong. Moreover, funding such a development poses a high risk for an individual supplier. The structure of the mask fabrication marketplace separates the mask writer equipment customer (the mask supplier) from the final customer (wafer manufacturer) that will be most effected by the increase in mask cost that will result if a high speed mask writer is not available. Since no individual company will likely risk entering this market, some type of industry-wide funding model will be needed.

  14. 21 CFR 868.5580 - Oxygen mask.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. (b) Classification...

  15. 21 CFR 868.5580 - Oxygen mask.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. (b) Classification...

  16. 21 CFR 868.5580 - Oxygen mask.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. (b) Classification...

  17. 21 CFR 868.5580 - Oxygen mask.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. (b) Classification...

  18. 21 CFR 868.5580 - Oxygen mask.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxygen mask. 868.5580 Section 868.5580 Food and... ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5580 Oxygen mask. (a) Identification. An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. (b) Classification...

  19. Metal oxide multilayer hard mask system for 3D nanofabrication

    NASA Astrophysics Data System (ADS)

    Han, Zhongmei; Salmi, Emma; Vehkamäki, Marko; Leskelä, Markku; Ritala, Mikko

    2018-02-01

    We demonstrate the preparation and exploitation of multilayer metal oxide hard masks for lithography and 3D nanofabrication. Atomic layer deposition (ALD) and focused ion beam (FIB) technologies are applied for mask deposition and mask patterning, respectively. A combination of ALD and FIB was used and a patterning procedure was developed to avoid the ion beam defects commonly met when using FIB alone for microfabrication. ALD grown Al2O3/Ta2O5/Al2O3 thin film stacks were FIB milled with 30 keV gallium ions and chemically etched in 5% tetramethylammonium hydroxide at 50 °C. With metal evaporation, multilayers consisting of amorphous oxides Al2O3 and Ta2O5 can be tailored for use in 2D lift-off processing, in preparation of embedded sub-100 nm metal lines and for multilevel electrical contacts. Good pattern transfer was achieved by lift-off process from the 2D hard mask for micro- and nano-scaled fabrication. As a demonstration of the applicability of this method to 3D structures, self-supporting 3D Ta2O5 masks were made from a film stack on gold particles. Finally, thin film resistors were fabricated by utilizing controlled stiction of suspended Ta2O5 structures.

  20. Simulation-based MDP verification for leading-edge masks

    NASA Astrophysics Data System (ADS)

    Su, Bo; Syrel, Oleg; Pomerantsev, Michael; Hagiwara, Kazuyuki; Pearman, Ryan; Pang, Leo; Fujimara, Aki

    2017-07-01

    For IC design starts below the 20nm technology node, the assist features on photomasks shrink well below 60nm and the printed patterns of those features on masks written by VSB eBeam writers start to show a large deviation from the mask designs. Traditional geometry-based fracturing starts to show large errors for those small features. As a result, other mask data preparation (MDP) methods have become available and adopted, such as rule-based Mask Process Correction (MPC), model-based MPC and eventually model-based MDP. The new MDP methods may place shot edges slightly differently from target to compensate for mask process effects, so that the final patterns on a mask are much closer to the design (which can be viewed as the ideal mask), especially for those assist features. Such an alteration generally produces better masks that are closer to the intended mask design. Traditional XOR-based MDP verification cannot detect problems caused by eBeam effects. Much like model-based OPC verification which became a necessity for OPC a decade ago, we see the same trend in MDP today. Simulation-based MDP verification solution requires a GPU-accelerated computational geometry engine with simulation capabilities. To have a meaningful simulation-based mask check, a good mask process model is needed. The TrueModel® system is a field tested physical mask model developed by D2S. The GPU-accelerated D2S Computational Design Platform (CDP) is used to run simulation-based mask check, as well as model-based MDP. In addition to simulation-based checks such as mask EPE or dose margin, geometry-based rules are also available to detect quality issues such as slivers or CD splits. Dose margin related hotspots can also be detected by setting a correct detection threshold. In this paper, we will demonstrate GPU-acceleration for geometry processing, and give examples of mask check results and performance data. GPU-acceleration is necessary to make simulation-based mask MDP verification

  1. Management of birth asphyxia in home deliveries in rural Gadchiroli: the effect of two types of birth attendants and of resuscitating with mouth-to-mouth, tube-mask or bag-mask.

    PubMed

    Bang, Abhay T; Bang, Rani A; Baitule, Sanjay B; Reddy, Hanimi M; Deshmukh, Mahesh D

    2005-03-01

    To evaluate the effect of home-based neonatal care on birth asphyxia and to compare the effectiveness of two types of workers and three methods of resuscitation in home delivery. In a field trial of home-based neonatal care in rural Gadchiroli, India, birth asphyxia in home deliveries was managed differently during different phases. Trained traditional birth attendants (TBA) used mouth-to-mouth resuscitation in the baseline years (1993 to 1995). Additional village health workers (VHWs) only observed in 1995 to 1996. In the intervention years (1996 to 2003), they used tube-mask (1996 to 1999) and bag-mask (1999 to 2003). The incidence, case fatality (CF) and asphyxia-specific mortality rate (ASMR) during different phases were compared. During the intervention years, 5033 home deliveries occurred. VHWs were present during 84% home deliveries. The incidence of mild birth asphyxia decreased by 60%, from 14% in the observation year (1995 to 1996) to 6% in the intervention years (p<0.0001). The incidence of severe asphyxia did not change significantly, but the CF in neonates with severe asphyxia decreased by 47.5%, from 39 to 20% (p<0.07) and ASMR by 65%, from 11 to 4% (p<0.02). Mouth-to-mouth resuscitation reduced the ASMR by 12%, tube-mask further reduced the CF by 27% and the ASMR by 67%. The bag-mask showed an additional decrease in CF of 39% and in the fresh stillbirth rate of 33% in comparison to tube-mask (not significant). The cost of bag and mask was US dollars 13 per averted death. Oxytocic injection administered by unqualified doctors showed an odds ratio of three for the occurrence of severe asphyxia or fresh stillbirth. Home-based interventions delivered by a team of TBA and a semiskilled VHW reduced the asphyxia-related neonatal mortality by 65% compared to only TBA. The bag-mask appears to be superior to tube-mask or mouth-to-mouth resuscitation, with an estimated equipment cost of US dollars 13 per death averted.

  2. What Do Contrast Threshold Equivalent Noise Studies Actually Measure? Noise vs. Nonlinearity in Different Masking Paradigms

    PubMed Central

    Baldwin, Alex S.; Baker, Daniel H.; Hess, Robert F.

    2016-01-01

    The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system’s input has on its output one can estimate the variance of this internal noise. By applying this simple “linear amplifier” model to the human visual system, one can entirely explain an observer’s detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system’s internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity). Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF). We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies. PMID:26953796

  3. [Effect of a surgical mask on six minute walking distance].

    PubMed

    Person, E; Lemercier, C; Royer, A; Reychler, G

    2018-03-01

    Six minutes walking test (6MWT) is regularly used in pulmonology. To minimize the risk of cross-infection, some patients must wear surgical mask at rest and sometimes during exercise. To evaluate the effect of wearing a surgical mask during 6MWT in healthy subjects. It is a prospective study on 44 healthy subjects. After a first 6MWT for training, they performed randomly two 6MWT: with or without a surgical mask. Distance and dyspnea, heart rate and saturation variations were recorded. Distance was not modified by the mask (P=0.99). Dyspnea variation was significantly higher with surgical mask (+5.6 vs. +4.6; P<0.001) and the difference was clinically relevant. No difference was found for the variation of other parameters. Wearing a surgical mask modifies significantly and clinically dyspnea without influencing walked distance. Copyright © 2017 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  4. Preparation of sildenafil citrate microcapsules and in vitro/in vivo evaluation of taste masking efficiency.

    PubMed

    Yi, Eun-Jin; Kim, Ju-Young; Rhee, Yun-Seok; Kim, Su-Hyeon; Lee, Hyo-Joong; Park, Chun-Woong; Park, Eun-Seok

    2014-05-15

    The aim of the present study was to prepare the particulate taste-masking system to mask the bitter taste of sildenafil citrate (SC), a well-known phosphodiesterase-5 inhibitor used for erectile dysfunction (ED) and pulmonary artery hypertension (PAH). It was evaluated for the taste masking efficiency by the in vitro measurement using electronic tongue (e-tongue) system and the in vivo human panel sensory test. Microcapsules were prepared by microencapsulation with a gastro-soluble polymer, Eudragit(®) E100 (E100), using a spray drying technique at four different weight ratios (2:1, 1:1, 1:2, and 1:3). Characters of prepared microcapsules and the effect of polymer ratio on the taste masking were investigated. The particle morphology and the distribution of SC in microcapsules were observed by SEM-EDS and physical properties were evaluated by PXRD, Raman spectroscopy, and DSC. By drug dissolution studies at pH 1.2 buffer and DW, it was found that E100 was not able to alter the drug release in stomach. As the result of taste evaluation studies, there were a good correlation (R(2)=0.9867) between the weight ratio of polymer and the taste masking efficiency expressed in the distances on the PCA map of the e-tongue data, and a relevance of the e-tongue measurement with the result of sensory test. Copyright © 2014. Published by Elsevier B.V.

  5. A masked negative self-esteem? Implicit and explicit self-esteem in patients with Narcissistic Personality Disorder.

    PubMed

    Marissen, Marlies A E; Brouwer, Marlies E; Hiemstra, Annemarie M F; Deen, Mathijs L; Franken, Ingmar H A

    2016-08-30

    The mask model of narcissism states that the narcissistic traits of patients with NPD are the result of a compensatory reaction to underlying ego fragility. This model assumes that high explicit self-esteem masks low implicit self-esteem. However, research on narcissism has predominantly focused on non-clinical participants and data derived from patients diagnosed with Narcissistic Personality Disorder (NPD) remain scarce. Therefore, the goal of the present study was to test the mask model hypothesis of narcissism among patients with NPD. Male patients with NPD were compared to patients with other PD's and healthy participants on implicit and explicit self-esteem. NPD patients did not differ in levels of explicit and implicit self-esteem compared to both the psychiatric and the healthy control group. Overall, the current study found no evidence in support of the mask model of narcissism among a clinical group. This implicates that it might not be relevant for clinicians to focus treatment of NPD on an underlying negative self-esteem. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Auditory Time-Frequency Masking for Spectrally and Temporally Maximally-Compact Stimuli

    PubMed Central

    Laback, Bernhard; Savel, Sophie; Ystad, Sølvi; Balazs, Peter; Meunier, Sabine; Kronland-Martinet, Richard

    2016-01-01

    Many audio applications perform perception-based time-frequency (TF) analysis by decomposing sounds into a set of functions with good TF localization (i.e. with a small essential support in the TF domain) using TF transforms and applying psychoacoustic models of auditory masking to the transform coefficients. To accurately predict masking interactions between coefficients, the TF properties of the model should match those of the transform. This involves having masking data for stimuli with good TF localization. However, little is known about TF masking for mathematically well-localized signals. Most existing masking studies used stimuli that are broad in time and/or frequency and few studies involved TF conditions. Consequently, the present study had two goals. The first was to collect TF masking data for well-localized stimuli in humans. Masker and target were 10-ms Gaussian-shaped sinusoids with a bandwidth of approximately one critical band. The overall pattern of results is qualitatively similar to existing data for long maskers. To facilitate implementation in audio processing algorithms, a dataset provides the measured TF masking function. The second goal was to assess the potential effect of auditory efferents on TF masking using a modeling approach. The temporal window model of masking was used to predict present and existing data in two configurations: (1) with standard model parameters (i.e. without efferents), (2) with cochlear gain reduction to simulate the activation of efferents. The ability of the model to predict the present data was quite good with the standard configuration but highly degraded with gain reduction. Conversely, the ability of the model to predict existing data for long maskers was better with than without gain reduction. Overall, the model predictions suggest that TF masking can be affected by efferent (or other) effects that reduce cochlear gain. Such effects were avoided in the experiment of this study by using maximally

  7. The Four-Quadrant Phase-Mask Coronagraph. II. Simulations

    NASA Astrophysics Data System (ADS)

    Riaud, P.; Boccaletti, A.; Rouan, D.; Lemarquis, F.; Labeyrie, A.

    2001-09-01

    In the first paper in this series, we described the principle of a coronagraph utilizing a four-quadrant phase mask and the results of numerical simulations obtained in the perfect case. In this second paper, we performed additional numerical simulations to assess in more detail the performances and limitations of this coronagraph under real conditions. The effect of geometrical parameters such as shape and size of both the phase mask and the Lyot stop is studied. We also analyze the effect of low- and high-order aberrations generated, for instance, by the atmospheric turbulence. An important issue is the wavelength dependence of the phase mask. We show that the performance decreases rapidly as the spectral bandwidth is increased, and as a consequence, we discuss the manufacturing of achromatized masks using multiple thin films. An optical concept is proposed.

  8. Structural colour printing from a reusable generic nanosubstrate masked for the target image

    NASA Astrophysics Data System (ADS)

    Rezaei, M.; Jiang, H.; Kaminska, B.

    2016-02-01

    Structural colour printing has advantages over traditional pigment-based colour printing. However, the high fabrication cost has hindered its applications in printing large-area images because each image requires patterning structural pixels in nanoscale resolution. In this work, we present a novel strategy to print structural colour images from a pixelated substrate which is called a nanosubstrate. The nanosubstrate is fabricated only once using nanofabrication tools and can be reused for printing a large quantity of structural colour images. It contains closely packed arrays of nanostructures from which red, green, blue and infrared structural pixels can be imprinted. To print a target colour image, the nanosubstrate is first covered with a mask layer to block all the structural pixels. The mask layer is subsequently patterned according to the target colour image to make apertures of controllable sizes on top of the wanted primary colour pixels. The masked nanosubstrate is then used as a stamp to imprint the colour image onto a separate substrate surface using nanoimprint lithography. Different visual colours are achieved by properly mixing the red, green and blue primary colours into appropriate ratios controlled by the aperture sizes on the patterned mask layer. Such a strategy significantly reduces the cost and complexity of printing a structural colour image from lengthy nanoscale patterning into high throughput micro-patterning and makes it possible to apply structural colour printing in personalized security features and data storage. In this paper, nanocone array grating pixels were used as the structural pixels and the nanosubstrate contains structures to imprint the nanocone arrays. Laser lithography was implemented to pattern the mask layer with submicron resolution. The optical properties of the nanocone array gratings are studied in detail. Multiple printed structural colour images with embedded covert information are demonstrated.

  9. Reinforced Masks for Ion Plating of Solar Cells

    NASA Technical Reports Server (NTRS)

    Conley, W. R.; Swick, E. G.; Volkers, J. C.

    1987-01-01

    Proposed mask for ion plating of surface electrodes on silicon solar cells reinforced to hold shape better during handling. Fabrication process for improved mask similar to conventional mask. Additional cuts and bends made in wide diametral strip to form bridges between pairs of mask fingers facing each other across this strip. Bridges high enough not to act as masks so entire strip area plated.

  10. Mechanically and electrically robust metal-mask design for organic CMOS circuits

    NASA Astrophysics Data System (ADS)

    Shintani, Michihiro; Qin, Zhaoxing; Kuribara, Kazunori; Ogasahara, Yasuhiro; Hiromoto, Masayuki; Sato, Takashi

    2018-04-01

    The design of metal masks for fabricating organic CMOS circuits requires the consideration of not only the electrical property of the circuits, but also the mechanical strength of the masks. In this paper, we propose a new design flow for metal masks that realizes coanalysis of the mechanical and electrical properties and enables design exploration considering the trade-off between the two properties. As a case study, we apply a “stitching technique” to the mask design of a ring oscillator and explore the best design. With this technique, mask patterns are divided into separate parts using multiple mask layers to improve the mechanical strength at the cost of high resistance of the vias. By a numerical experiment, the design trade-off of the stitching technique is quantitatively analyzed, and it is demonstrated that the proposed flow is useful for the exploration of the designs of metal masks.

  11. The efficacy of three different mask styles on a PAP titration night.

    PubMed

    Ebben, Matthew R; Oyegbile, Temitayo; Pollak, Charles P

    2012-06-01

    This study compared the efficacy of three different masks, nasal pillows, nasal masks and full face (oronasal) masks, during a single night of titration with continuous positive airway pressure (CPAP). Fifty five subjects that included men (n=33) and women (n=22) were randomly assigned to one of three masks and underwent a routine titration with incremental CPAP applied through the different masks. CPAP applied through the nasal pillows and nasal mask was equally effective in treating mild, moderate, and severe sleep apnea. However, CPAP applied through the oronasal mask required a significantly higher pressure compared to nasal masks to treat moderately severe (2.8 cm of H(2)O ± 2.1 SD) and severe (6.0 cm of H(2)O ± 3.2 SD) obstructive sleep apnea. CPAP applied with either nasal mask was effective in treating mild, moderate, and severe sleep apnea. The oronasal mask required significantly higher pressures in subjects with moderate to severe disease. Therefore, when changing from a nasal to an oronasal mask, a repeat titration is required to ensure effective treatment of sleep apnea, especially in patients with moderate to severe disease. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Mask industry assessment trend analysis: 2012

    NASA Astrophysics Data System (ADS)

    Chan, Y. David

    2012-02-01

    Microelectronics industry leaders consistently cite the cost and cycle time of mask technology and mask supply among the top critical issues for lithography. A survey was designed by SEMATECH with input from semiconductor company mask technologists and merchant mask suppliers to objectively assess the overall conditions of the mask industry. With the continued support of the industry, this year's assessment was the tenth in the current series of annual reports. This year's survey is basically the same as the 2005 through 2011 surveys. Questions are grouped into six categories: General Business Profile Information, Data Processing, Yields and Yield Loss Mechanisms, Delivery Times, Returns, and Services. Within each category is a multitude of questions that ultimately produce a detailed profile of both the business and technical status of the critical mask industry. We received data from 11 companies this year, which was a record high since the beginning of the series. The responding companies represented more than 96% of the volume shipped and about 90% of the 2011 revenue for the photomask industry. These survey reports are often used as a baseline to gain perspective on the technical and business status of the mask and microelectronics industries. They will continue to serve as a valuable reference to identify strengths and opportunities. Results can also be used to guide future investments in critical path issues.

  13. Facial and ocular deposition of nebulized budesonide: effects of face mask design.

    PubMed

    Harris, Keith W; Smaldone, Gerald C

    2008-02-01

    In vivo case reports and in vitro studies have indicated that aerosol therapy using face masks can result in drug deposition on the face and in the eyes, and that face mask design may affect drug delivery. To test different mask/nebulizer combinations for budesonide, a nebulized steroid used to treat pediatric patients with asthma. Using high-performance liquid chromatography, drug delivery (inhaled mass), facial, and ocular deposition of budesonide aerosols were studied in vitro using a ventilated face facsimile (tidal volume, 50 mL; rate, 25 breaths/min, duty cycle 0.4), a tight-fitting test mask, a standard commercial mask, and a prototype mask designed to optimize delivery by reducing particle inertia. Nebulizer insertion into the mask (front loaded vs bottom loaded) was also tested. Particle size was measured by cascade impaction. Pari LC Plus (PARI Respiratory Equipment; Midlothian, VA) and MistyNeb (Allegiance; McGaw Park, IL) nebulizers were tested. Inhaled mass for tight-fitting and prototype masks was similar (13.2 +/- 1.85% vs 14.4 +/- 0.67% [percentage of nebulizer charge], p = 0.58) and significantly greater than for the commercial mask (3.03 +/- 0.26%, p = 0.005). Mask insertion of nebulizer was a key factor (inhaled mass: front loaded vs bottom loaded, 8.23 +/- 0.18% vs 3.03 +/- 0.26%; p = 0.005). Ocular deposition varied by an order of magnitude and was a strong function of mask design (4.77 +/- 0.24% vs 0.35 +/- 0.05%, p = 0.002, tight fitting vs prototype). Particle sizes (7.3 to 9 microm) were larger than previously reported for budesonide. For pediatric breathing patterns, mask design is a key factor defining budesonide delivery to the lungs, face, and eyes. Front-loaded nebulizer mask combinations are more efficient than bottom-loaded systems.

  14. Masking responses to light in period mutant mice.

    PubMed

    Pendergast, Julie S; Yamazaki, Shin

    2011-10-01

    Masking is an acute effect of an external signal on an overt rhythm and is distinct from the process of entrainment. In the current study, we investigated the phase dependence and molecular mechanisms regulating masking effects of light pulses on spontaneous locomotor activity in mice. The circadian genes, Period1 (Per1) and Per2, are necessary components of the timekeeping machinery and entrainment by light appears to involve the induction of the expression of Per1 and Per2 mRNAs in the suprachiasmatic nuclei (SCN). We assessed the roles of the Per genes in regulating masking by assessing the effects of light pulses on nocturnal locomotor activity in C57BL/6J Per mutant mice. We found that Per1(-/-) and Per2(-/-) mice had robust negative masking responses to light. In addition, the locomotor activity of Per1(-/-)/Per2(-/-) mice appeared to be rhythmic in the light-dark (LD) cycle, and the phase of activity onset was advanced (but varied among individual mice) relative to lights off. This rhythm persisted for 1 to 2 days in constant darkness in some Per1(-/-)/Per2(-/-) mice. Furthermore, Per1(-/-)/Per2(-/-) mice exhibited robust negative masking responses to light. Negative masking was phase dependent in wild-type mice such that maximal suppression was induced by light pulses at zeitgeber time 14 (ZT14) and gradually weaker suppression occurred during light pulses at ZT16 and ZT18. By measuring the phase shifts induced by the masking protocol (light pulses were administered to mice maintained in the LD cycle), we found that the phase responsiveness of Per mutant mice was altered compared to wild-types. Together, our data suggest that negative masking responses to light are robust in Per mutant mice and that the Per1(-/-)/Per2(-/-) SCN may be a light-driven, weak/damping oscillator.

  15. An experimental investigation of masking in the US FDA adverse event reporting system database.

    PubMed

    Wang, Hsin-wei; Hochberg, Alan M; Pearson, Ronald K; Hauben, Manfred

    2010-12-01

    A phenomenon of 'masking' or 'cloaking' in pharmacovigilance data mining has been described, which can potentially cause signals of disproportionate reporting (SDRs) to be missed, particularly in pharmaceutical company databases. Masking has been predicted theoretically, observed anecdotally or studied to a limited extent in both pharmaceutical company and health authority databases, but no previous publication systematically assesses its occurrence in a large health authority database. To explore the nature, extent and possible consequences of masking in the US FDA Adverse Event Reporting System (AERS) database by applying various experimental unmasking protocols to a set of drugs and events representing realistic pharmacovigilance analysis conditions. This study employed AERS data from 2001 through 2005. For a set of 63 Medical Dictionary for Regulatory Activities (MedDRA®) Preferred Terms (PTs), disproportionality analysis was carried out with respect to all drugs included in the AERS database, using a previously described urn-model-based algorithm. We specifically sought masking in which drug removal induced an increase in the statistical representation of a drug-event combination (DEC) that resulted in the emergence of a new SDR. We performed a series of unmasking experiments selecting drugs for removal using rational statistical decision rules based on the requirement of a reporting ratio (RR) >1, top-ranked statistical unexpectedness (SU) and relatedness as reflected in the WHO Anatomical Therapeutic Chemical level 4 (ATC4) grouping. In order to assess the possible extent of residual masking we performed two supplemental purely empirical analyses on a limited subset of data. This entailed testing every drug and drug group to determine which was most influential in uncovering masked SDRs. We assessed the strength of external evidence for a causal association for a small number of masked SDRs involving a subset of 29 drugs for which level of evidence

  16. Rapid iconic erasure without masking.

    PubMed

    Tijus, Charles Albert; Reeves, Adam

    2004-01-01

    We report on the erasure of the iconic memory of an array of 12 black letters flashed on a continuously- present white field. Erasure is accomplished by replacing the 16 ms letter array (frame 1) with a blank white frame for 16 ms (frame 2). The letter array returns in frame 3, with from one to six letters missing. Report of the missing letters is accurate without the blank white frame but is impoverished with it, as if interposing the blank erases the icon. Erasure occurs without any obvious luminance masking, 'mud splashes', pattern masking (backward, forward, or metacontrast), lateral masking, or masking by object substitution. Erasure is greatly decreased if the blank is presented one frame earlier or later. We speculate that erasure is due to a rapid reset of the icon produced by an informational mis-match.

  17. Migration from full‐head mask to “open‐face” mask for immobilization of patients with head and neck cancer

    PubMed Central

    Lovelock, D. Michael; Mechalakos, James; Rao, Shyam; Della‐Biancia, Cesar; Amols, Howard; Lee, Nancy

    2013-01-01

    To provide an alternative device for immobilization of the head while easing claustrophobia and improving comfort, an “open‐face” thermoplastic mask was evaluated using video‐based optical surface imaging (OSI) and kilovoltage (kV) X‐ray radiography. A three‐point thermoplastic head mask with a precut opening and reinforced strips was developed. After molding, it provided sufficient visible facial area as the region of interest for OSI. Using real‐time OSI, the head motion of ten volunteers in the new mask was evaluated during mask locking and 15 minutes lying on the treatment couch. Using a nose mark with reference to room lasers, forced head movement in open‐face and full‐head masks (with a nose hole) was compared. Five patients with claustrophobia were immobilized with open‐face masks, set up using OSI and kV, and treated in 121 fractions, in which 61 fractions were monitored during treatment using real‐time OSI. With the open‐face mask, head motion was found to be 1.0 ± 0.6 mm and 0.4° ± 0.2° in volunteers during the experiment, and 0.8 ± 0.3 mm and 0.4° ± 0.2° in patients during treatment. These agree with patient motion calculated from pre‐/post‐treatment OSI and kV data using different anatomical landmarks. In volunteers, the head shift induced by mask‐locking was 2.3 ± 1.7 mm and 1.8° ± 0.6°, and the range of forced movements in the open‐face and full‐head masks were found to be similar. Most (80%) of the volunteers preferred the open‐face mask to the full‐head mask, while claustrophobic patients could only tolerate the open‐face mask. The open‐face mask is characterized for its immobilization capability and can immobilize patients sufficiently (< 2 mm) during radiotherapy. It provides a clinical solution to the immobilization of patients with head and neck (HN) cancer undergoing radiotherapy, and is particularly beneficial for claustrophobic patients. This new open

  18. Masks for prevention of respiratory viruses on the BMT unit: results of a quality initiative.

    PubMed

    Sokol, Kelsey A; De la Vega-Diaz, Imelda; Edmondson-Martin, Kathleen; Kim, Sara; Tindle, Sharon; Wallach, Fran; Steinberg, Amir

    2016-12-01

    Respiratory viral infections (RVI) cause significant morbidity and mortality in hospitalized oncology patients. These viruses are easily spread from asymptomatic and/or symptomatic healthcare workers and visitors to immunocompromised patients, and literature review of facemasks for prevention of infection revealed mixed results. The Bone Marrow Transplant (BMT) Quality Assurance (QA) Committee at Mount Sinai began a surgical mask initiative on the BMT unit. The purpose of our initiative was to assess the impact of surgical mask implementation for healthcare workers and visitors on nosocomial RVI in all patients hospitalized on the BMT unit. We hypothesized that implementing surgical masks would reduce the number of hospital-acquired RVI. We performed a retrospective study involving all patients with malignancy hospitalized on the BMT unit for 4 years. During the latter 2 years, all healthcare workers and visitors were required to wear a surgical mask in every patient room on the BMT unit. Primary endpoint was incidence of RVI after implementation of surgical masks. The 2-year incidence of RVI in the pre-mask period was 14 out of a total of 15 001 patient days on the unit vs 2 out of 15 608 patient days after mask implementation. The difference in incidence of RVI within the two time intervals was noted to be statistically significant (P<.05, 2-proportion z-test). Our quality initiative demonstrated that surgical masks are an infection control modality that may provide benefit to oncology/BMT units by decreasing the risk for hospital-acquired RVI. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Time course of dichoptic masking in normals and suppression in amblyopes.

    PubMed

    Zhou, Jiawei; McNeal, Suzanne; Babu, Raiju J; Baker, Daniel H; Bobier, William R; Hess, Robert F

    2014-04-17

    To better understand the relationship between dichoptic masking in normal vision and suppression in amblyopia we address three questions: First, what is the time course of dichoptic masking in normals and amblyopes? Second, is interocular suppression low-pass or band-pass in its spatial dependence? And third, in the above two regards, is dichoptic masking in normals different from amblyopic suppression? We measured the dependence of dichoptic masking in normal controls and amblyopes on the temporal duration of presentation under three conditions; monocular (the nontested eye-i.e., dominant eye of normals or nonamblyopic eye of amblyopes, being patched), dichoptic-luminance (the nontested eye seeing a mean luminance-i.e., a DC component) and dichoptic-contrast (the nontested eye seeing high-contrast visual noise). The subject had to detect a letter in the other eye, the contrast of which was varied. We found that threshold elevation relative to the patched condition occurred in both normals and amblyopes when the nontested eye saw either 1/f or band-pass filtered noise, but not just mean luminance (i.e., there was no masking from the DC component that corresponds to a channel responsive to a spatial frequency of 0 cyc/deg); longer presentation of the target (corresponding to lower temporal frequencies) produced greater threshold elevation. Dichoptic masking exhibits similar properties in both subject groups, being low-pass temporally and band-pass spatially, so that masking was greatest at the longest presentation durations and was not greatly affected by mean luminance in the nontested eye. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  20. EUV mask pilot line at Intel Corporation

    NASA Astrophysics Data System (ADS)

    Stivers, Alan R.; Yan, Pei-Yang; Zhang, Guojing; Liang, Ted; Shu, Emily Y.; Tejnil, Edita; Lieberman, Barry; Nagpal, Rajesh; Hsia, Kangmin; Penn, Michael; Lo, Fu-Chang

    2004-12-01

    The introduction of extreme ultraviolet (EUV) lithography into high volume manufacturing requires the development of a new mask technology. In support of this, Intel Corporation has established a pilot line devoted to encountering and eliminating barriers to manufacturability of EUV masks. It concentrates on EUV-specific process modules and makes use of the captive standard photomask fabrication capability of Intel Corporation. The goal of the pilot line is to accelerate EUV mask development to intersect the 32nm technology node. This requires EUV mask technology to be comparable to standard photomask technology by the beginning of the silicon wafer process development phase for that technology node. The pilot line embodies Intel's strategy to lead EUV mask development in the areas of the mask patterning process, mask fabrication tools, the starting material (blanks) and the understanding of process interdependencies. The patterning process includes all steps from blank defect inspection through final pattern inspection and repair. We have specified and ordered the EUV-specific tools and most will be installed in 2004. We have worked with International Sematech and others to provide for the next generation of EUV-specific mask tools. Our process of record is run repeatedly to ensure its robustness. This primes the supply chain and collects information needed for blank improvement.

  1. Does technology acceleration equate to mask cost acceleration?

    NASA Astrophysics Data System (ADS)

    Trybula, Walter J.; Grenon, Brian J.

    2003-06-01

    The technology acceleration of the ITRS Roadmap has many implications on both the semiconductor sup-plier community and the manufacturers. INTERNATIONAL SEMATECH has revaluated the projected cost of advanced technology masks. Building on the methodology developed in 1996 for mask costs, this work provided a critical review of mask yields and factors relating to the manufacture of photolithography masks. The impact of the yields provided insight into the learning curve for leading edge mask manufac-turing. The projected mask set cost was surprising, and the ability to provide first and second year cost estimates provided additional information on technology introduction. From this information, the impact of technology acceleration can be added to the projected yields to evaluate the impact on mask costs.

  2. Failure of the Laryngeal Mask Airway Unique™ and Classic™ in the pediatric surgical patient: a study of clinical predictors and outcomes.

    PubMed

    Mathis, Michael R; Haydar, Bishr; Taylor, Emma L; Morris, Michelle; Malviya, Shobha V; Christensen, Robert E; Ramachandran, Satya-Krishna; Kheterpal, Sachin

    2013-12-01

    Although predictors of laryngeal mask airway failure in adults have been elucidated, there remains a paucity of data regarding laryngeal mask airway failure in children. The authors performed a retrospective database review of all pediatric patients who received a laryngeal mask anesthetic at their institution from 2006 to 2010. Device brands were restricted to LMA Unique™ (Cardinal Health, Dublin, OH) and LMA Classic™ (LMA North America, San Diego, CA), and primary outcome was laryngeal mask failure, defined as any airway event requiring device removal and tracheal intubation. Potential risk factors were analyzed with both univariate and multivariate techniques and included medical history, physical examination, surgical, and anesthetic characteristics. Of the 11,910 anesthesia cases performed in the study, 102 cases (0.86%) experienced laryngeal mask failure. Common presenting features of laryngeal mask failures included leak (25%), obstruction (48%), and patient intolerance such as intractable coughing/bucking (11%). Failures occurred before incision in 57% of cases and after incision in 43%. Independent clinical associations included ear/nose/throat surgical procedure, nonoutpatient admission status, prolonged surgical duration, congenital/acquired airway abnormality, and patient transport. The findings of the study support the use of the LMA Unique™ and LMA Classic™ as reliable pediatric supraglottic airway devices, demonstrating relatively low failure rates. Predictors of laryngeal mask airway failure in the pediatric surgical population do not overlap with those in the adult population and should therefore be independently considered.

  3. Vibration-Assisted Femtosecond Laser Drilling with Controllable Taper Angles for AMOLED Fine Metal Mask Fabrication

    PubMed Central

    Choi, Wonsuk; Kim, Hoon Young; Jeon, Jin Woo; Chang, Won Seok; Cho, Sung-Hak

    2017-01-01

    This study investigates the effect of focal plane variation using vibration in a femtosecond laser hole drilling process on Invar alloy fabrication quality for the production of fine metal masks (FMMs). FMMs are used in the red, green, blue (RGB) evaporation process in Active Matrix Organic Light-Emitting Diode (AMOLED) manufacturing. The taper angle of the hole is adjusted by attaching the objective lens to a micro-vibrator and continuously changing the focal plane position. Eight laser pulses were used to examine how the hole characteristics vary with the first focal plane’s position, where the first pulse is focused at an initial position and the focal planes of subsequent pulses move downward. The results showed that the hole taper angle can be controlled by varying the amplitude of the continuously operating vibrator during femtosecond laser hole machining. The taper angles were changed between 31.8° and 43.9° by adjusting the vibrator amplitude at a frequency of 100 Hz. Femtosecond laser hole drilling with controllable taper angles is expected to be used in the precision micro-machining of various smart devices. PMID:28772571

  4. Assessing validity of observational intervention studies – the Benchmarking Controlled Trials

    PubMed Central

    Malmivaara, Antti

    2016-01-01

    Abstract Background: Benchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations. Aims: To create and pilot test a checklist for appraising methodological validity of a BCT. Methods: The checklist was created by extracting the most essential elements from the comprehensive set of criteria in the previous paper on BCTs. Also checklists and scientific papers on observational studies and respective systematic reviews were utilized. Ten BCTs published in the Lancet and in the New England Journal of Medicine were used to assess feasibility of the created checklist. Results: The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies. Conclusions: The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. However, the piloted checklist should be validated in further studies.Key messagesBenchmarking Controlled Trial (BCT) is a concept which covers all observational studies aiming to assess impact of interventions or health care system features to patients and populations.This paper presents a checklist for appraising methodological validity of BCTs and pilot-tests the checklist with ten BCTs published in leading medical journals. The appraised studies seem to have several methodological limitations, some of which could be avoided in planning, conducting and reporting phases of the studies.The checklist can be used for planning, conducting, reporting, reviewing, and critical reading of observational intervention studies. PMID:27238631

  5. Removable pellicle for lithographic mask protection and handling

    DOEpatents

    Klebanoff, Leonard E.; Rader, Daniel J.; Hector, Scott D.; Nguyen, Khanh B.; Stulen, Richard H.

    2002-01-01

    A removable pellicle for a lithographic mask that provides active and robust particle protection, and which utilizes a traditional pellicle and two deployments of thermophoretic protection to keep particles off the mask. The removable pellicle is removably attached via a retaining structure to the mask substrate by magnetic attraction with either contacting or non-contacting magnetic capture mechanisms. The pellicle retaining structural is composed of an anchor piece secured to the mask substrate and a frame member containing a pellicle. The anchor piece and the frame member are in removable contact or non-contact by the magnetic capture or latching mechanism. In one embodiment, the frame member is retained in a floating (non-contact) relation to the anchor piece by magnetic levitation. The frame member and the anchor piece are provided with thermophoretic fins which are interdigitated to prevent particles from reaching the patterned area of the mask. Also, the anchor piece and mask are maintained at a higher temperature than the frame member and pellicle which also prevents particles from reaching the patterned mask area by thermophoresis. The pellicle can be positioned over the mask to provide particle protection during mask handling, inspection, and pumpdown, but which can be removed manually or robotically for lithographic use of the mask.

  6. An observation tool to study air traffic control and flightdeck collaboration.

    PubMed

    Cox, Gemma; Sharples, Sarah; Stedmon, Alex; Wilson, John

    2007-07-01

    The complex systems of the flightdeck (FD) and the Air Traffic Control Centre (ATC) are characterised by numerous concurrently operating and interacting communication channels between people and between people and machines/computer systems. This paper describes work in support of investigating the impact of changes to technologies and responsibilities within this system with respect to human factors. It focuses primarily on the introduction of datalink (text-based communication rather than traditional radio communication) and the move towards freeflight (pilot-mediated air traffic control). Air traffic management investigations have outlined these specific changes as strategies to enable further increases in the volume of air traffic. A systems approach was taken and field studies were conducted. Small numbers of domain experts such as air traffic controllers (ATCOs) were involved in the field-based observations of how people interact with systems and each other. This paper summarises the overall research approach taken and then specifically reports on the field-based observations including the justification, development, and findings of the observation tool used. The observation tool examined information propagation through the air traffic control-flightdeck (ATC-FD) system, and resulted in models of possible information trajectories through the system.

  7. Reticle writer for next-generation SEMI mask standard: mask handling and exposure

    NASA Astrophysics Data System (ADS)

    Ehrlich, Christian

    1998-12-01

    The world semiconductor industry is currently preparing itself for the next evolutionary step in the ongoing development of the integrated circuit, characterized by the 0.18 to 0.15 micrometer technology. The already complex engineering task for the mask tool makers is furthermore complicated by the introduction of the new SEMI reticle standard with a 230 mm by 230 mm large and 9 mm thick quartz glass blank that will have a weight of more than one kilogram. The production of these advanced masks is already identified as a key enabling technology which will stretch the capabilities of the manufacturing process, and its equipment, to the limit. The mask making e-beam system Leica ZBA320, capable of exposing a 230 mm reticle and featuring the variable shaped beam approach with a 20 kV accelerating voltage has been introduced recently. Now the first results of e-beam exposures with this new type of mask writer are presented. Enhancements form the previous generation system include improved deflection systems, stage metrology, pattern data handling, and an address grid down to 10 nanometers. This system's specified performance enables it to produce reticles designed to support semiconductor fabrication utilizing 180 nanometer design rules, and beyond, with high accuracy and productivity.

  8. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.

    PubMed

    Qureshi, Mosarrat J; Kumar, Manoj

    2018-03-15

    Providing effective positive pressure ventilation is considered to be the single most important component of successful neonatal resuscitation. Ventilation is frequently initiated manually with bag and face mask (BMV) followed by endotracheal intubation if respiratory depression continues. These techniques may be difficult to perform successfully resulting in prolonged resuscitation or neonatal asphyxia. The laryngeal mask airway (LMA) may achieve initial ventilation and successful resuscitation faster than a bag-mask device or endotracheal intubation. Among newborns requiring positive pressure ventilation for cardio-pulmonary resuscitation, is LMA more effective than BMV or endotracheal intubation for successful resuscitation? When BMV is either insufficient or ineffective, is effective positive pressure ventilation and successful resuscitation achieved faster with the LMA compared to endotracheal intubation? We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2017, Issue 1), MEDLINE via PubMed (1966 to 15 February 2017), Embase (1980 to 15 February 2017), and CINAHL (1982 to 15 February 2017). We also searched clinical trials registers, conference proceedings, and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. We included randomised and quasi-randomised controlled trials that compared LMA for neonatal resuscitation with either BMV or endotracheal intubation and reported on any outcomes related to neonatal resuscitation specified in this review. Two review authors independently evaluated studies for risk of bias assessments, and extracted data using Cochrane Neonatal criteria. Categorical treatment effects were described as relative risks and continuous treatment effects were described as the mean difference, with 95% confidence intervals (95% CI) of estimates. We included seven trials that involved a total of 794 infants. Five

  9. On the origin of increased sensitivity and mass resolution using silicon masks in MALDI.

    PubMed

    Diologent, Laurent; Franck, Julien; Wisztorski, Maxence; Treizebre, Anthony; Focsa, Cristian; Fournier, Isabelle; Ziskind, Michael

    2014-02-04

    Since its development, MALDI has proved its performance in the analysis of intact biomolecules up to high molecular weights, regardless of their polarity. Sensitivity of MALDI instruments is a key point for breaking the limits of observing biomolecules of lower abundances. Instrumentation is one way to improve sensitivity by increasing ion transmission and using more sensitive detection systems. On the other side, improving MALDI ion production yields would have important outcomes. MALDI ion production is still not well-controlled and, indeed, the amount of ions produced per laser shot with respect to the total volume of desorbed material is very low. This has particular implications for certain applications, such as MALDI MS imaging where laser beam focusing as fine as possible (5-10 μm) is searched in order to reach higher spatial resolution images. However, various studies point out an intrinsic decrease in signal intensity for strong focusing. We have therefore been interested in developing silicon mask systems to decrease an irradiated area by cutting rather than focusing the laser beam and to study the parameters affecting sensitivity using such systems. For this, we systematically examined variation with laser fluence of intensity and spectral resolution in MALDI of standard peptides when using silicon-etched masks of various aperture sizes. These studies demonstrate a simultaneous increase in spectral resolution and signal intensity. Origin of this effect is discussed in the frame of the two-step ionization model. Experimental data in the low fluence range are fitted with an increase of the primary ionization through matrix-silicon edge contact provided by the masks. On the other hand, behavior at higher fluence could be explained by an effect on the secondary ionization via changes in the plume dynamics.

  10. A mask manufacturer's perspective on maskless lithography

    NASA Astrophysics Data System (ADS)

    Buck, Peter; Biechler, Charles; Kalk, Franklin

    2005-11-01

    Maskless Lithography (ML2) is again being considered for use in mainstream CMOS IC manufacturing. Sessions at technical conferences are being devoted to ML2. A multitude of new companies have been formed in the last several years to apply new concepts to breaking the throughput barrier that has in the past prevented ML2 from achieving the cost and cycle time performance necessary to become economically viable, except in rare cases. Has Maskless Lithography's (we used to call it "Direct Write Lithography") time really come? If so, what is the expected impact on the mask manufacturer and does it matter? The lithography tools used today in mask manufacturing are similar in concept to ML2 except for scale, both in throughput and feature size. These mask tools produce highly accurate lithographic images directly from electronic pattern files, perform multi-layer overlay, and mix-n-match across multiple tools, tool types and sites. Mask manufacturers are already accustomed to the ultimate low volume - one substrate per design layer. In order to achieve the economically required throughput, proposed ML2 systems eliminate or greatly reduce some of the functions that are the source of the mask writer's accuracy. Can these ML2 systems meet the demanding lithographic requirements without these functions? ML2 may eliminate the reticle but many of the processes and procedures performed today by the mask manufacturer are still required. Examples include the increasingly complex mask data preparation step and the verification performed to ensure that the pattern on the reticle is accurately representing the design intent. The error sources that are fixed on a reticle are variable with time on an ML2 system. It has been proposed that if ML2 is successful it will become uneconomical to be in the mask business - that ML2, by taking the high profit masks will take all profitability out of mask manufacturing and thereby endanger the entire semiconductor industry. Others suggest that a

  11. Estimating subglottal pressure via airflow interruption with auditory masking.

    PubMed

    Hoffman, Matthew R; Jiang, Jack J

    2009-11-01

    Current noninvasive measurement of subglottal pressure using airflow interruption often produces inconsistent results due to the elicitation of audio-laryngeal reflexes. Auditory feedback could be considered as a means of ensuring measurement accuracy and precision. The purpose of this study was to determine if auditory masking could be used with the airflow interruption system to improve intrasubject consistency. A prerecorded sample of subject phonation was played on a loop over headphones during the trials with auditory masking. This provided subjects with a target pitch and blocked out distracting ambient noise created by the airflow interrupter. Subglottal pressure was noninvasively measured using the airflow interruption system. Thirty subjects, divided into two equal groups, performed 10 trials without auditory masking and 10 trials with auditory masking. Group one performed the normal trials first, followed by the trials with auditory masking. Group two performed the auditory masking trials first, followed by the normal trials. Intrasubject consistency was improved by adding auditory masking, resulting in a decrease in average intrasubject standard deviation from 0.93+/-0.51 to 0.47+/-0.22 cm H(2)O (P < 0.001). Auditory masking can be used effectively to combat audio-laryngeal reflexes and aid subjects in maintaining constant glottal configuration and frequency, thereby increasing intrasubject consistency when measuring subglottal pressure. By considering auditory feedback, a more reliable method of measurement was developed. This method could be used by clinicians, as reliable, immediately available values of subglottal pressure are useful in evaluating laryngeal health and monitoring treatment progress.

  12. Emergence times and airway reactions in general laryngeal mask airway anesthesia: study protocol for a randomized controlled trial.

    PubMed

    Stevanovic, Ana; Rossaint, Rolf; Keszei, András P; Fritz, Harald; Fröba, Gebhard; Pühringer, Friedrich; Coburn, Mark

    2015-07-26

    The use of a laryngeal mask airway (LMA) in appropriate patients supports fast-track anesthesia with a lower incidence of postoperative airway-connected adverse events. Data on the most favorable anesthetic in this context, with the lowest rate of upper airway complications and fast emergence times, are controversial and limited. Desflurane seems to match these criteria best, but large randomized controlled trials (RCTs) with a standardized study protocol are lacking. Therefore, we aim to compare desflurane with other commonly used anesthetics, sevoflurane and propofol, in a sufficiently powered RCT. We hypothesize that desflurane is noninferior regarding the frequency of upper airway events and superior regarding the emergence times to sevoflurane and propofol. A total of 351 patients undergoing surgery with an LMA will be included in this prospective, randomized, double-blind controlled, multicenter clinical trial. The patients will be randomly assigned to the three treatment arms: desflurane (n = 117), sevoflurane (n = 117), and propofol (n = 117). The emergence time (time to state the date of birth) will be the primary endpoint of this study. The secondary endpoints include further emergence times, such as time to open eyes, to remove LMA, to respond to command and to state name. Additionally, we will determine the frequency of cough and laryngospasm, measured intraoperatively and at emergence. We will assess the postoperative recovery on the first postoperative day via the Postoperative Quality Recovery Scale. Despite increasing importance of cost-effective and safe anesthesia application, we lack proof for the most advantageous anesthetic agent, when an LMA is used. There are only a few RCTs comparing desflurane to other commonly used anesthetics (sevoflurane, propofol and isoflurane) in patients with LMA. These RCTs were conducted with small sample sizes, huge interstudy variability, and some also showed strong biases. The present multicenter RCT will

  13. Barriers to mask wearing for influenza-like illnesses among urban Hispanic households.

    PubMed

    Ferng, Yu-hui; Wong-McLoughlin, Jennifer; Barrett, Angela; Currie, Leanne; Larson, Elaine

    2011-01-01

    To identify barriers to mask wearing and to examine the factors associated with the willingness to wear masks among households. We used data sources from a study assessing the impact of 3 nonpharmaceutical interventions on the rates of influenza: exit interviews; home visits with a subset of the mask group; and a focus group. Risk perception score, univariate analysis, and logistic regression were conducted to identify the characteristics and predictors of mask use. Thematic barriers to mask wearing were identified from qualitative data obtained at home visits and focus group. Respondents from the mask group, when compared with the nonmask group, demonstrated higher risk perception scores concerning influenza (maximum score: 60, means: 37.6 and 30.2, p<.001) and increased perception of effectiveness of mask wearing (maximum score: 10, means: 7.8 and 7.3, p=.043). There was no significant association between demographic, attitudinal, or knowledge variables and adherence to wearing masks. Thematic barriers were identified such as social acceptability of mask use, comfort and fit, and perception of the risk/need for masks. Face masks may not be an effective intervention for seasonal or pandemic influenza unless the risk perception of influenza is high. Dissemination of culturally appropriate mask use information by health authorities and providers must be emphasized when educating the public. © 2010 Wiley Periodicals, Inc.

  14. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    PubMed Central

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; p<0.001). With oronasal masks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  15. Voice Quality After a Semi-Occluded Vocal Tract Exercise With a Ventilation Mask in Contemporary Commercial Singers: Acoustic Analysis and Self-Assessments.

    PubMed

    Fantini, Marco; Succo, Giovanni; Crosetti, Erika; Borragán Torre, Alfonso; Demo, Roberto; Fussi, Franco

    2017-05-01

    The current study aimed at investigating the immediate effects of a semi-occluded vocal tract exercise with a ventilation mask in a group of contemporary commercial singers. A randomized controlled study was carried out. Thirty professional or semi-professional singers with no voice complaints were randomly divided into two groups on recruitment: an experimental group and a control group. The same warm-up exercise was performed by the experimental group with an occluded ventilation mask placed over the nose and the mouth and by the control group without the ventilation mask. Voice was recorded before and after the exercise. Acoustic and self-assessment analysis were accomplished. The acoustic parameters of the voice samples recorded before and after training were compared, as well as the parameters' variations between the experimental and the control group. Self-assessment results of the experimental and the control group were compared too. Significant changes after the warm-up exercise included jitter, shimmer, and singing power ratio (SPR) in the experimental group. No significant changes were recorded in the control group. Significant differences between the experimental and the control group were found for ΔShimmer and ΔSPR. Self-assessment analysis confirmed a significantly higher phonatory comfort and voice quality perception for the experimental group. The results of the present study support the immediate advantageous effects on singing voice of a semi-occluded vocal tract exercise with a ventilation mask in terms of acoustic quality, phonatory comfort, and voice quality perception in contemporary commercial singers. Long-term effects still remain to be studied. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  16. The Mask Designs for Space Interferometer Mission (SIM)

    NASA Technical Reports Server (NTRS)

    Wang, Xu

    2008-01-01

    The Space Interferometer Mission (SIM) consists of three interferometers (science, guide1, and guide2) and two optical paths (metrology and starlight). The system requirements for each interferometer/optical path combination are different and sometimes work against each other. A diffraction model is developed to design and optimize various masks to simultaneously meet the system requirements of three interferometers. In this paper, the details of this diffraction model will be described first. Later, the mask design for each interferometer will be presented to demonstrate the system performance compliance. In the end, a tolerance sensitivity study on the geometrical dimension, shape, and the alignment of these masks will be discussed.

  17. The magic of 4X mask reduction

    NASA Astrophysics Data System (ADS)

    Lercel, Michael

    2006-06-01

    Although changing the mask reduction factor from 4X to a larger value offers several technical advantages, previous attempts to enact this change have not identified enough clear technical advantages to overcome the impact to productivity. Improvements in mask manufacturing, mask polarization effects, and optics cost have not been thought to be sufficient reason to accept a reduced throughput and field size. This paper summarizes the latest workshop and discussion revisiting the mask reduction factor for 32nm half-pitch lithography with hyper-numerical aperture (NA) optical or extreme ultraviolet lithography (EUVL). The workshop consensus was strongly in favor of maintaining the current magnification ratio and field size as long as mask costs can be contained.

  18. Masking overshoot: Effects of ipsilateral, bilateral and contralateral priming

    NASA Astrophysics Data System (ADS)

    Connington, Maureen Catherine

    This study was concerned with masking overshoot, the elevation of the threshold of a brief signal when it is presented at the onset of a masking noise rather than at its temporal center. More specifically, it was concerned with the release from overshoot (i.e., threshold improvement) produced by priming stimuli, presented ipsilaterally, bilaterally and contralaterally at primer- masker gaps of 20, 40 and 80 msec. The more general purpose of the study was to assess the contributions of peripheral and central factors to the overshoot and overshoot-release phenomena. The primers and masking stimuli consisted of white noise bursts of 200 and 400 msec duration, respectively. The probe signal was a 20 msec 4kHz tone. The tone and masker were always presented in one ear. There were, however, 3 modes of primer presentation: ipsilateral, bilateral (identical waveforms to both ears) and contralateral. Three primer-masker gaps of 20, 40 and 80 msec were used. Five normally hearing adults were tested at primer and masker levels of 80 dB HL. Four of the five subjects exhibited significant masking overshoot, when tested without priming. Ipsilateral priming with 20 and 40 msec gaps produced significant masking release from overshoot. Threshold became poorer, however with increasing gap duration and with increasing distance of the perceived primer from the test ear (i.e. ipsilateral priming produced better thresholds than did bilateral priming and bilateral priming produced better thresholds than contralateral priming). There was significant masking enhancement (i.e. threshold was significantly poorer than in the unprimed probe at onset condition) with the contralateral 80 msec primer. The fact that ipsilateral and bilateral primers performed differently does not support the theory that masking overshoot and its release are solely the results of peripheral adaptation. In fact, the group results support the conclusion that masking overshoot is influenced by central factors. However

  19. Comparison of cloud optical depth and cloud mask applying BRDF model-based background surface reflectance

    NASA Astrophysics Data System (ADS)

    Kim, H. W.; Yeom, J. M.; Woo, S. H.

    2017-12-01

    Over the thin cloud region, satellite can simultaneously detect the reflectance from thin clouds and land surface. Since the mixed reflectance is not the exact cloud information, the background surface reflectance should be eliminated to accurately distinguish thin cloud such as cirrus. In the previous research, Kim et al (2017) was developed the cloud masking algorithm using the Geostationary Ocean Color Imager (GOCI), which is one of significant instruments for Communication, Ocean, and Meteorology Satellite (COMS). Although GOCI has 8 spectral channels including visible and near infra-red spectral ranges, the cloud masking has quantitatively reasonable result when comparing with MODIS cloud mask (Collection 6 MYD35). Especially, we noticed that this cloud masking algorithm is more specialized in thin cloud detections through the validation with Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) data. Because this cloud masking method was concentrated on eliminating background surface effects from the top-of-atmosphere (TOA) reflectance. Applying the difference between TOA reflectance and the bi-directional reflectance distribution function (BRDF) model-based background surface reflectance, cloud areas both thick cloud and thin cloud can be discriminated without infra-red channels which were mostly used for detecting clouds. Moreover, when the cloud mask result was utilized as the input data when simulating BRDF model and the optimized BRDF model-based surface reflectance was used for the optimized cloud masking, the probability of detection (POD) has higher value than POD of the original cloud mask. In this study, we examine the correlation between cloud optical depth (COD) and its cloud mask result. Cloud optical depths mostly depend on the cloud thickness, the characteristic of contents, and the size of cloud contents. COD ranges from less than 0.1 for thin clouds to over 1000 for the huge cumulus due to scattering by droplets. With

  20. Evaluation of a native vegetation masking technique

    NASA Technical Reports Server (NTRS)

    Kinsler, M. C.

    1984-01-01

    A crop masking technique based on Ashburn's vegetative index (AVI) was used to evaluate native vegetation as an indicator of crop moisture condition. A mask of the range areas (native vegetation) was generated for each of thirteen Great Plains LANDSAT MSS sample segments. These masks were compared to the digitized ground truth and accuracies were computed. An analysis of the types of errors indicates a consistency in errors among the segments. The mask represents a simple quick-look technique for evaluating vegetative cover.

  1. Inverse lithography using sparse mask representations

    NASA Astrophysics Data System (ADS)

    Ionescu, Radu C.; Hurley, Paul; Apostol, Stefan

    2015-03-01

    We present a novel optimisation algorithm for inverse lithography, based on optimization of the mask derivative, a domain inherently sparse, and for rectilinear polygons, invertible. The method is first developed assuming a point light source, and then extended to general incoherent sources. What results is a fast algorithm, producing manufacturable masks (the search space is constrained to rectilinear polygons), and flexible (specific constraints such as minimal line widths can be imposed). One inherent trick is to treat polygons as continuous entities, thus making aerial image calculation extremely fast and accurate. Requirements for mask manufacturability can be integrated in the optimization without too much added complexity. We also explain how to extend the scheme for phase-changing mask optimization.

  2. Effects of vitamin D supplementation on insulin resistance and cardiometabolic risk factors in children with metabolic syndrome: a triple-masked controlled trial.

    PubMed

    Kelishadi, Roya; Salek, Shadi; Salek, Mehdi; Hashemipour, Mahin; Movahedian, Mahsa

    2014-01-01

    This triple-masked controlled trial aimed to assess the effects of vitamin D supplementation on insulin resistance and cardiometabolic risk factors in obese children and adolescents. The study comprised 50 participants, aged 10 to 16 years, who were randomly assigned into two groups of equal number. In this 12-week trial, one group received oral vitamin D (300,000 IU) and the other group received placebo. Cardiometabolic risk factors, insulin resistance, and a continuous value of metabolic syndrome (cMetS) were determined. Statistical analysis was conducted after adjustment for covariate interactions. Overall, 21 patients in the vitamin D group and 22 in the placebo group completed the trial. No significant difference was observed in the baseline characteristics of the two groups. After the trial, in the vitamin D group, serum insulin and triglyceride concentrations, as well as HOM -IR and C-MetS decreased significantly, both when compared with the baseline and with the placebo group. No significant difference was observed when comparing total cholesterol, LDL-C, HDL-C, fasting blood glucose, and blood pressure. The present findings support the favorable effects of vitamin D supplementation on reducing insulin resistance and cardiometabolic risk factors in obese children. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  3. Cost-effective masks for deep x-ray lithography

    NASA Astrophysics Data System (ADS)

    Scheunemann, Heinz-Ulrich; Loechel, Bernd; Jian, Linke; Schondelmaier, Daniel; Desta, Yohannes M.; Goettert, Jost

    2003-04-01

    The production of X-ray masks is one of the key techniques for X-ray lithography and the LIGA process. Different ways for the fabrication of X-ray masks has been established. Very sophisticated, difficult and expensive procedures are required to produce high precision and high quality X-ray masks. In order to minimize the cost of an X-ray mask, the mask blank must be inexpensive and readily available. The steps involved in the fabrication process must also be minimal. In the past, thin membranes made of titanium, silicon carbide, silicon nitride (2-5μm) or thick beryllium substrates (500μm) have been used as mask blanks. Thin titanium and silicon compounds have very high transparency for X-rays; therefore, these materials are predestined for use as mask membrane material. However, the handling and fabrication of thin membranes is very difficult, thus expensive. Beryllium is highly transparent to X-rays, but the processing and use of beryllium is risky due to potential toxicity. During the past few years graphite based X-ray masks have been in use at various research centers, but the sidewall quality of the generated resist patterns is in the range of 200-300 nm Ra. We used polished graphite to improve the sidewall roughness, but polished graphite causes other problems in the fabrication of X-ray masks. This paper describes the advantages associated with the use of polished graphite as mask blank as well as the fabrication process for this low cost X-ray mask. Alternative membrane materials will also be discussed.

  4. Timolol LA: a double-masked, active-controlled, randomized, crossover, comfort, ocular safety, and systemic bioavailability study in healthy volunteers.

    PubMed

    Mundorf, Thomas K; Ogawa, Takahiro; Inui, Noritsugu; Naka, Hiroaki; Novack, Gary D; Crockett, R Stephens

    2005-03-01

    A new formulation of timolol with sorbic acid, timolol-LA (TLA) (Istaloldagger), has been developed which increases its ocular bioavailability. In the present study, we desired to evaluate the ocular comfort and systemic bioavailability of TLA in healthy volunteers in comparison to standard timolol maleate ophthalmic solution (TIM). This study was a randomized, double-masked, active-controlled, crossover evaluation of 0.5% TLA and 0.5% TIM, bid, in 12 normal healthy volunteers. Visits were at Days 0, 1, 2, 4 and 8 in each period, and there was a minimum 7 day interperiod washout. At all three post-dosing evaluation times (Day 1: Peak, Day 8: Trough, and Day 8: Peak), the 95% confidence interval for the difference between TLA and TIM was not more than 0.37 ng/mL. After administration of TLA, there was a greater incidence of burning/stinging and tearing, but not foreign body sensation, relative to TIM. In general, most symptoms were mild in intensity, and no subject discontinued treatment due to ocular discomfort. Both treatments decreased IOP to a similar level. TLA was relatively comfortable, with a safety profile consistent with further clinical development, and, with bid dosing (exaggerated [2X] that anticipated for clinical use), had a systemic bioavailability similar to that of TIM 0.5%, bid. The incidence of burning and stinging was higher with TLA than with TIM, although reports were mild in severity and did not result in any patient discontin uations. Although the results are of interest, further evaluation in a larger trial may be warranted.

  5. Masking Level Difference Response Norms from Learning Disabled Individuals.

    ERIC Educational Resources Information Center

    Waryas, Paul A.; Battin, R. Ray

    1985-01-01

    The study presents normative data on Masking Level Difference (an improvement of the auditory processing of interaural time/intensity differences between signals and masking noises) for 90 learning disabled persons (4-35 years old). It was concluded that the MLD may quickly screen for auditory processing problems. (CL)

  6. The prevalence effect in lateral masking and its relevance for visual search.

    PubMed

    Geelen, B P; Wertheim, A H

    2015-04-01

    In stimulus displays with or without a single target amid 1,644 identical distractors, target prevalence was varied between 20, 50 and 80 %. Maximum gaze deviation was measured to determine the strength of lateral masking in these arrays. The results show that lateral masking was strongest in the 20 % prevalence condition, which differed significantly from both the 50 and 80 % prevalence conditions. No difference was observed between the latter two. This pattern of results corresponds to that found in the literature on the prevalence effect in visual search (stronger lateral masking corresponding to longer search times). The data add to similar findings reported earlier (Wertheim et al. in Exp Brain Res, 170:387-402, 2006), according to which the effects of many well-known factors in visual search correspond to those on lateral masking. These were the effects of set size, disjunctions versus conjunctions, display area, distractor density, the asymmetry effect (Q vs. O's) and viewing distance. The present data, taken together with those earlier findings, may lend credit to a causal hypothesis that lateral masking could be a more important mechanism in visual search than usually assumed.

  7. Mask Ventilation during Induction of General Anesthesia: Influences of Obstructive Sleep Apnea.

    PubMed

    Sato, Shin; Hasegawa, Makoto; Okuyama, Megumi; Okazaki, Junko; Kitamura, Yuji; Sato, Yumi; Ishikawa, Teruhiko; Sato, Yasunori; Isono, Shiroh

    2017-01-01

    Depending on upper airway patency during anesthesia induction, tidal volume achieved by mask ventilation may vary. In 80 adult patients undergoing general anesthesia, the authors tested a hypothesis that tidal volume during mask ventilation is smaller in patients with sleep-disordered breathing priorly defined as apnea hypopnea index greater than 5 per hour. One-hand mask ventilation with a constant ventilator setting (pressure-controlled ventilation) was started 20 s after injection of rocuronium and maintained for 1 min during anesthesia induction. Mask ventilation efficiency was assessed by the breath number needed to initially exceed 5 ml/kg ideal body weight of expiratory tidal volume (primary outcome) and tidal volumes (secondary outcomes) during initial 15 breaths (UMIN000012494). Tidal volume progressively increased by more than 70% in 1 min and did not differ between sleep-disordered breathing (n = 42) and non-sleep-disordered breathing (n = 38) patients. In post hoc subgroup analyses, the primary outcome breath number (mean [95% CI], 5.7 [4.1 to 7.3] vs. 1.7 [0.2 to 3.2] breath; P = 0.001) and mean tidal volume (6.5 [4.6 to 8.3] vs. 9.6 [7.7 to 11.4] ml/kg ideal body weight; P = 0.032) were significantly smaller in 20 sleep-disordered breathing patients with higher apnea hypopnea index (median [25th to 75th percentile]: 21.7 [17.6 to 31] per hour) than in 20 non-sleep disordered breathing subjects with lower apnea hypopnea index (1.0 [0.3 to 1.5] per hour). Obesity and occurrence of expiratory flow limitation during one-hand mask ventilation independently explained the reduction of efficiency of mask ventilation, while the use of two hands effectively normalized inefficient mask ventilation during one-hand mask ventilation. One-hand mask ventilation is difficult in patients with obesity and severe sleep-disordered breathing particularly when expiratory flow limitation occurs during mask ventilation.

  8. Effect of Otitis Media with Effusion on Comodulation Masking Release in Children.

    ERIC Educational Resources Information Center

    Hall, Joseph W.; Grose, John H.

    1994-01-01

    This study investigated comodulation masking release (CMR) in 42 children (ages 5 to 10) with a history of otitis media with effusion (OME) and 19 control children with no history of ear disease. Results indicated that monotic CMRs were reduced in children with hearing loss due to OME and these CMRs remained abnormally small for several months.…

  9. Informational Masking and Spatial Hearing in Listeners with and without Unilateral Hearing Loss

    ERIC Educational Resources Information Center

    Rothpletz, Ann M.; Wightman, Frederic L.; Kistler, Doris J.

    2012-01-01

    Purpose: This study assessed selective listening for speech in individuals with and without unilateral hearing loss (UHL) and the potential relationship between spatial release from informational masking and localization ability in listeners with UHL. Method: Twelve adults with UHL and 12 normal-hearing controls completed a series of monaural and…

  10. Mask technology for EUV lithography

    NASA Astrophysics Data System (ADS)

    Bujak, M.; Burkhart, Scott C.; Cerjan, Charles J.; Kearney, Patrick A.; Moore, Craig E.; Prisbrey, Shon T.; Sweeney, Donald W.; Tong, William M.; Vernon, Stephen P.; Walton, Christopher C.; Warrick, Abbie L.; Weber, Frank J.; Wedowski, Marco; Wilhelmsen, Karl C.; Bokor, Jeffrey; Jeong, Sungho; Cardinale, Gregory F.; Ray-Chaudhuri, Avijit K.; Stivers, Alan R.; Tejnil, Edita; Yan, Pei-yang; Hector, Scott D.; Nguyen, Khanh B.

    1999-04-01

    Extreme UV Lithography (EUVL) is one of the leading candidates for the next generation lithography, which will decrease critical feature size to below 100 nm within 5 years. EUVL uses 10-14 nm light as envisioned by the EUV Limited Liability Company, a consortium formed by Intel and supported by Motorola and AMD to perform R and D work at three national laboratories. Much work has already taken place, with the first prototypical cameras operational at 13.4 nm using low energy laser plasma EUV light sources to investigate issues including the source, camera, electro- mechanical and system issues, photoresists, and of course the masks. EUV lithograph masks are fundamentally different than conventional photolithographic masks as they are reflective instead of transmissive. EUV light at 13.4 nm is rapidly absorbed by most materials, thus all light transmission within the EUVL system from source to silicon wafer, including EUV reflected from the mask, is performed by multilayer mirrors in vacuum.

  11. Effect of test exercises and mask donning on measured respirator fit.

    PubMed

    Crutchfield, C D; Fairbank, E O; Greenstein, S L

    1999-12-01

    Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.

  12. Continuous positive airway pressure with helmet versus mask in infants with bronchiolitis: an RCT.

    PubMed

    Chidini, Giovanna; Piastra, Marco; Marchesi, Tiziana; De Luca, Daniele; Napolitano, Luisa; Salvo, Ida; Wolfler, Andrea; Pelosi, Paolo; Damasco, Mirco; Conti, Giorgio; Calderini, Edoardo

    2015-04-01

    Noninvasive continuous positive airway pressure (CPAP) is usually applied with a nasal or facial mask to treat mild acute respiratory failure (ARF) in infants. A pediatric helmet has now been introduced in clinical practice to deliver CPAP. This study compared treatment failure rates during CPAP delivered by helmet or facial mask in infants with respiratory syncytial virus-induced ARF. In this multicenter randomized controlled trial, 30 infants with respiratory syncytial virus-induced ARF were randomized to receive CPAP by helmet (n = 17) or facial mask (n = 13). The primary endpoint was treatment failure rate (defined as due to intolerance or need for intubation). Secondary outcomes were CPAP application time, number of patients requiring sedation, and complications with each interface. Compared with the facial mask, CPAP by helmet had a lower treatment failure rate due to intolerance (3/17 [17%] vs 7/13 [54%], P = .009), and fewer infants required sedation (6/17 [35%] vs 13/13 [100%], P = .023); the intubation rates were similar. In successfully treated patients, CPAP resulted in better gas exchange and breathing pattern with both interfaces. No major complications due to the interfaces occurred, but CPAP by mask had higher rates of cutaneous sores and leaks. These findings confirm that CPAP delivered by helmet is better tolerated than CPAP delivered by facial mask and requires less sedation. In addition, it is safe to use and free from adverse events, even in a prolonged clinical setting. Copyright © 2015 by the American Academy of Pediatrics.

  13. Development of Personalized Fitting Device With 3-Dimensional Solution for Prevention of NIV Oronasal Mask-Related Pressure Ulcers.

    PubMed

    Shikama, Maiko; Nakagami, Gojiro; Noguchi, Hiroshi; Mori, Taketoshi; Sanada, Hiromi

    2018-05-22

    Pressure ulcers related to oronasal masks used with noninvasive ventilation (NIV), along with patient discomfort, occur due to improper fit of the mask. We developed a personalized fitting device using a 3-dimensional (3D) scanning solution to prevent the formation of NIV mask-related pressure ulcers. This study aimed to evaluate the effectiveness of the proposed personalized fitting device. We conducted a randomized crossover experimental study of 20 healthy participants to study the use of this personalized fitting device between the face and an NIV mask designed with 3D solutions. The fitting device was not used under the NIV mask for the control. The outcome measures were the presence of blanchable erythema, standardized redness intensity, discomfort level, and contact pressure. The incidence of blanchable erythema and standardized redness intensity values were significantly lower for subjects who used the fitting device when worn for 30 min ( P < .001). The discomfort levels at the forehead, nasal bridge, and both cheeks, as well as leakage, were significantly reduced as well ( P = .008, P < .001, P = .001, P = .002, P = .001, P = .02, P < .001, P < .001, P < .001). Contact pressure at the nasal bridge, where pressure ulcers most frequently develop, was significantly decreased with the fitting device ( P < .001). Personalized fitting devices that incorporate 3D scanning solutions may contribute to the prevention of NIV mask-related pressure ulcers and the reduction of discomfort. Copyright © 2018 by Daedalus Enterprises.

  14. A concealed observational study of infection control and safe injection practices in Jordanian governmental hospitals.

    PubMed

    Al-Rawajfah, Omar M; Tubaishat, Ahmad

    2017-10-01

    The recognized international organizations on infection prevention recommend using an observational method as the gold standard procedure for assessing health care professional's compliance with standard infection control practices. However, observational studies are rarely used in Jordanian infection control studies. This study aimed to evaluate injection practices among nurses working in Jordanian governmental hospitals. A cross-sectional concealed observational design is used for this study. A convenience sampling technique was used to recruit a sample of nurses working in governmental hospitals in Jordan. Participants were unaware of the time and observer during the observation episode. A total of 384 nurses from 9 different hospitals participated in the study. A total of 835 injections events were observed, of which 73.9% were performed without handwashing, 64.5% without gloving, and 27.5% were followed by needle recapping. Handwashing rate was the lowest (18.9%) when injections were performed by beginner nurses. Subcutaneous injections were associated with the lowest rate (26.7%) of postinjection handwashing compared with other routes. This study demonstrates the need for focused and effective infection control educational programs in Jordanian hospitals. Future studies should consider exploring the whole infection control practices related to waste disposal and the roles of the infection control nurse in this process in Jordanian hospitals. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  15. Randomized controlled trials vs. observational studies: why not just live together?

    PubMed

    Faraoni, David; Schaefer, Simon Thomas

    2016-10-21

    Randomized controlled trials (RCTs) are considered the gold standard for clinical research, thus having a high impact on clinical guidelines and our daily patients' care. However, various treatment strategies which we consider "evidence based" have never been subject to a prospective RCT, as we would rate it unethical to withheld an established treatment to individuals in an placebo controlled trial.In a recent BMC Anesthesiology publication, Trentino et al. analyzed the usefulness of observational studies in assessing benefit and risk of different transfusion strategies. The authors nicely reviewed and summarized similarities and differences, advantages and limitations, between different study types frequently used in transfusion medicine. In this interesting article, the authors conclude, that 'when comparing the results of observational studies with RCTs assessing transfusion outcomes, it is important that one consider not only the study method, but also the key elements of the study design'. Thus, in this commentary we now discuss the pro's and con's of different study types, even irrespective of transfusion medicine.

  16. Easy facial analysis using the facial golden mask.

    PubMed

    Kim, Yong-Ha

    2007-05-01

    For over 2000 years, many artists and scientists have tried to understand or quantify the form of the perfect, ideal, or most beautiful face both in art and in vivo (life). A mathematical relationship has been consistently and repeatedly reported to be present in beautiful things. This particular relationship is the golden ratio. It is a mathematical ratio of 1.618:1 that seems to appear recurrently in beautiful things in nature as well as in other things that are seen as beautiful. Dr. Marquardt made the facial golden mask that contains and includes all of the one-dimensional and two-dimensional geometric golden elements formed from the golden ratio. The purpose of this study is to evaluate the usefulness of the golden facial mask. In 40 cases, the authors applied the facial golden mask to preoperative and postoperative photographs and scored each photograph on a 1 to 5 scale from the perspective of their personal aesthetic views. The score was lower when the facial deformity was severe, whereas it was higher when the face was attractive. Compared with the average scores of facial mask applied photographs and nonapplied photographs using a nonparametric test, statistical significance was not reached (P > 0.05). This implies that the facial golden mask may be used as an analytical tool. The facial golden mask is easy to apply, inexpensive, and relatively objective. Therefore, the authors introduce it as a useful facial analysis.

  17. Homophone Dominance Modulates the Phonemic-Masking Effect.

    ERIC Educational Resources Information Center

    Berent, Iris; Van Orden, Guy C.

    2000-01-01

    Finds (1) positive phonemic-masking effects occurred for dominant homophones; (2) null phonemic-masking effects occurred for subordinate homophones; and (3) subordinate homophones were much more likely to be falsely identified as their dominant mate. Suggests the source of these null phonemic-masking is itself a phonology effect. Concludes…

  18. The total face mask is more comfortable than the oronasal mask in noninvasive ventilation but is not associated with improved outcome.

    PubMed

    Chacur, Fernando Hauaji; Vilella Felipe, Luis Marcelo; Fernandes, Cintia Gonçalves; Lazzarini, Luiz Claudio Oliveira

    2011-01-01

    Noninvasive positive-pressure ventilation (NPPV) is commonly used to improve ventilation and oxygenation and avoid endotracheal intubation and mechanical ventilation. Although clinically indicated, most patients fail to use NPPV due to mask intolerance. A total face mask was designed to increase compliance, but whether this translates into better outcome (improvement in clinical and blood gas parameters and less intubation) is unknown. We compared the evolution of the clinical parameters, blood gases, levels of ventilatory support and rate of endotracheal intubation using the total face mask or the traditional oronasal mask during NPPV. A total of 60 patients were randomized to use either mask during NPPV. The clinical and laboratory parameters, as well as the level of ventilatory support were recorded at different intervals in both groups for up to 6 h. In addition, the tolerance for each mask and the need for endotracheal intubation were compared. Patients tolerated the total face mask significantly better (p = 0.0010) and used NPPV for a longer time (p = 0.0017) when compared with the oronasal mask. Just 1 patient switched to the total face mask because of intolerance. Although better tolerated, the rate of endotracheal intubation was similar in both groups (p = 0.4376), as was the clinical and laboratory evolution. The total face mask was more comfortable, allowing the patients to tolerate NPPV longer; however, these accomplishments did not translate into a better outcome. Due to its comfort, the total face mask should be available, at least as an option, in units where NPPVs are routinely applied. Copyright © 2011 S. Karger AG, Basel.

  19. 21 CFR 868.5560 - Gas mask head strap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  20. Computerized Dead-Space Volume Measurement of Face Masks Applied to Simulated Faces.

    PubMed

    Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Marzuk, Chatib; Daitzchman, Marcelo; Newhouse, Michael T

    2015-09-01

    The dead-space volume (VD) of face masks for metered-dose inhaler treatments is particularly important in infants and young children with asthma, who have relatively low tidal volumes. Data about VD have been traditionally obtained from water displacement measurements, in which masks are held against a flat surface. Because, in real life, masks are placed against the face, VD is likely to differ considerably between masks depending upon their contour and fit. The aim of this study was to develop an accurate and reliable way to measure VD electronically and to apply this technique by comparing the electronic VD of commonly available face masks. Average digital faces were obtained from 3-dimensional images of 270 infants and children. Commonly used face masks (small and medium) from various manufacturers (Monaghan Medical, Pari Respiratory Equipment, Philips Respironics, and InspiRx) were scanned and digitized by means of computed tomography. Each mask was electronically applied to its respective digital face, and the VD enclosed (mL) was computerized and precisely measured. VD varied between 22.6 mL (SootherMask, InspiRx) and 43.1 mL (Vortex, Pari) for small masks and between 41.7 mL (SootherMask) and 71.5 mL (AeroChamber, Monaghan Medical) for medium masks. These values were significantly lower and less variable than measurements obtained by water displacement. Computerized techniques provide an innovative and relatively simple way of accurately measuring the VD of face masks applied to digital faces. As determined by computerized measurement using average-size virtual faces, the InspiRx masks had a significantly smaller VD for both small and medium masks compared with the other masks. This is of considerable importance with respect to aerosol dose and delivery time, particularly in young children. (ClinicalTrials.gov registration NCT01274299.). Copyright © 2015 by Daedalus Enterprises.