Metacontrast masking and attention do not interact.
Agaoglu, Sevda; Breitmeyer, Bruno; Ogmen, Haluk
2016-07-01
Visual masking and attention have been known to control the transfer of information from sensory memory to visual short-term memory. A natural question is whether these processes operate independently or interact. Recent evidence suggests that studies that reported interactions between masking and attention suffered from ceiling and/or floor effects. The objective of the present study was to investigate whether metacontrast masking and attention interact by using an experimental design in which saturation effects are avoided. We asked observers to report the orientation of a target bar randomly selected from a display containing either two or six bars. The mask was a ring that surrounded the target bar. Attentional load was controlled by set-size and masking strength by the stimulus onset asynchrony between the target bar and the mask ring. We investigated interactions between masking and attention by analyzing two different aspects of performance: (i) the mean absolute response errors and (ii) the distribution of signed response errors. Our results show that attention affects observers' performance without interacting with masking. Statistical modeling of response errors suggests that attention and metacontrast masking exert their effects by independently modulating the probability of "guessing" behavior. Implications of our findings for models of attention are discussed.
bin‐Reza, Faisal; Lopez Chavarrias, Vicente; Nicoll, Angus; Chamberland, Mary E.
2011-01-01
Please cite this paper as: bin‐Reza et al. (2012) The use of masks and respirators to prevent transmission of influenza: a systematic review of the scientific evidence. Influenza and Other Respiratory Viruses 6(4), 257–267. There are limited data on the use of masks and respirators to reduce transmission of influenza. A systematic review was undertaken to help inform pandemic influenza guidance in the United Kingdom. The initial review was performed in November 2009 and updated in June 2010 and January 2011. Inclusion criteria included randomised controlled trials and quasi‐experimental and observational studies of humans published in English with an outcome of laboratory‐confirmed or clinically‐diagnosed influenza and other viral respiratory infections. There were 17 eligible studies. Six of eight randomised controlled trials found no significant differences between control and intervention groups (masks with or without hand hygiene; N95/P2 respirators). One household trial found that mask wearing coupled with hand sanitiser use reduced secondary transmission of upper respiratory infection/influenza‐like illness/laboratory‐confirmed influenza compared with education; hand sanitiser alone resulted in no reduction. One hospital‐based trial found a lower rate of clinical respiratory illness associated with non‐fit‐tested N95 respirator use compared with medical masks. Eight of nine retrospective observational studies found that mask and/or respirator use was independently associated with a reduced risk of severe acute respiratory syndrome (SARS). Findings, however, may not be applicable to influenza and many studies were suboptimal. None of the studies established a conclusive relationship between mask/respirator use and protection against influenza infection. Some evidence suggests that mask use is best undertaken as part of a package of personal protection especially hand hygiene. The effectiveness of masks and respirators is likely linked to early, consistent and correct usage. PMID:22188875
Reduced OSM for Long Duration Targets: Individuation or Items Loaded into VSTM?
ERIC Educational Resources Information Center
Guest, Duncan; Gellatly, Angus; Pilling, Michael
2012-01-01
Typical studies of object substitution masking (OSM) employ a briefly presented search array. The target item is indicated by a cue/mask that surrounds but does not overlap the target and, compared to a common offset control condition, report of the target is reduced when the mask remains present after target offset. Given how little observers are…
Metacontrast masking is processed before grapheme-color synesthesia.
Bacon, Michael Patrick; Bridgeman, Bruce; Ramachandran, Vilayanur S
2013-01-01
We investigated the physiological mechanism of grapheme-color synesthesia using metacontrast masking. A metacontrast target is rendered invisible by a mask that is delayed by about 60 ms; the target and mask do not overlap in space or time. Little masking occurs, however, if the target and mask are simultaneous. This effect must be cortical, because it can be obtained dichoptically. To compare the data for synesthetes and controls, we developed a metacontrast design in which nonsynesthete controls showed weaker dichromatic masking (i.e., the target and mask were in different colors) than monochromatic masking. We accomplished this with an equiluminant target, mask, and background for each observer. If synesthetic color affected metacontrast, synesthetes should show monochromatic masking more similar to the weak dichromatic masking among controls, because synesthetes could add their synesthetic color to the monochromatic condition. The target-mask pairs used for each synesthete were graphemes that elicited strong synesthetic colors. We found stronger monochromatic than dichromatic U-shaped metacontrast for both synesthetes and controls, with optimal masking at an asynchrony of 66 ms. The difference in performance between the monochromatic and dichromatic conditions in the synesthetes indicates that synesthesia occurs at a later processing stage than does metacontrast masking.
Flavored Anesthetic Masks for Inhalational Induction in Children.
Gupta, Aakriti; Mathew, Preethy Joseph; Bhardwaj, Neerja
2017-10-01
To evaluate the clinical efficacy of masking the odor of inhalational agents using fruit flavors on the anxiety behavior and compliance of children for inhalational induction. A prospective randomized double blind, placebo controlled study was conducted on 60 unpremedicated children in the age group of 4-12 y. Thirty children received anesthetic masks smeared with a flavor of child's choice while the other 30 children were induced using masks without flavor. Anxiety was assessed using modified Yale Pre-operative Anxiety Scale (mYPAS) in the pre-op room and during inhalational induction. Mask acceptance was graded by Induction Compliance Checklist (ICC). The cost-effectiveness of flavored anesthetic masks was compared to that of commercially available pre-scented masks. The baseline anxiety in the two groups was comparable. The number of children demonstrating high levels of anxiety at anesthetic induction was similar in flavored and non-flavored mask groups (p 0.45). The compliance to mask induction was also equally good (p 0.99). The authors found significant difference in the cost of flavored mask (INR 56.45 per mask) as compared to commercially available pre-scented masks (INR 660 per mask). The authors observed a placebo effect that reduced the pre-op anxiety in the control group which probably made the quality of induction equivalent with flavored and non-flavored masks. Therefore, using a flavored anesthetic mask is cost-effective than using a commercially available pre-scented mask.
Dissociable brain mechanisms underlying the conscious and unconscious control of behavior.
van Gaal, Simon; Lamme, Victor A F; Fahrenfort, Johannes J; Ridderinkhof, K Richard
2011-01-01
Cognitive control allows humans to overrule and inhibit habitual responses to optimize performance in challenging situations. Contradicting traditional views, recent studies suggest that cognitive control processes can be initiated unconsciously. To further capture the relation between consciousness and cognitive control, we studied the dynamics of inhibitory control processes when triggered consciously versus unconsciously in a modified version of the stop task. Attempts to inhibit an imminent response were often successful after unmasked (visible) stop signals. Masked (invisible) stop signals rarely succeeded in instigating overt inhibition but did trigger slowing down of response times. Masked stop signals elicited a sequence of distinct ERP components that were also observed on unmasked stop signals. The N2 component correlated with the efficiency of inhibitory control when elicited by unmasked stop signals and with the magnitude of slowdown when elicited by masked stop signals. Thus, the N2 likely reflects the initiation of inhibitory control, irrespective of conscious awareness. The P3 component was much reduced in amplitude and duration on masked versus unmasked stop trials. These patterns of differences and similarities between conscious and unconscious cognitive control processes are discussed in a framework that differentiates between feedforward and feedback connections in yielding conscious experience.
On the effectiveness of noise masks: naturalistic vs. un-naturalistic image statistics.
Hansen, Bruce C; Hess, Robert F
2012-05-01
It has been argued that the human visual system is optimized for identification of broadband objects embedded in stimuli possessing orientation averaged power spectra fall-offs that obey the 1/f(β) relationship typically observed in natural scene imagery (i.e., β=2.0 on logarithmic axes). Here, we were interested in whether individual spatial channels leading to recognition are functionally optimized for narrowband targets when masked by noise possessing naturalistic image statistics (β=2.0). The current study therefore explores the impact of variable β noise masks on the identification of narrowband target stimuli ranging in spatial complexity, while simultaneously controlling for physical or perceived differences between the masks. The results show that β=2.0 noise masks produce the largest identification thresholds regardless of target complexity, and thus do not seem to yield functionally optimized channel processing. The differential masking effects are discussed in the context of contrast gain control. Copyright © 2012 Elsevier Ltd. All rights reserved.
Study of shape evaluation for mask and silicon using large field of view
NASA Astrophysics Data System (ADS)
Matsuoka, Ryoichi; Mito, Hiroaki; Shinoda, Shinichi; Toyoda, Yasutaka
2010-09-01
We have developed a highly integrated method of mask and silicon metrology. The aim of this integration is evaluating the performance of the silicon corresponding to Hotspot on a mask. It can use the mask shape of a large field, besides. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. As an optimal solution to these issues, we provide a DFM solution that extracts 2-dimensional data for a more realistic and error-free simulation by reproducing accurately the contour of the actual mask, in addition to the simulation results from the mask data. On the other hand, there is roughness in the silicon form made from a mass-production line. Moreover, there is variation in the silicon form. For this reason, quantification of silicon form is important, in order to estimate the performance of a pattern. In order to quantify, the same form is equalized in two dimensions. And the method of evaluating based on the form is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. •Discrimination of nuisance defects for fine pattern. •Determination of two-dimensional variability of pattern. •Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the form of the same location of Design, Mask, and Silicon in such a viewpoint. And we report it about algorithm of the image composition in Large Field.
Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy
NASA Technical Reports Server (NTRS)
Newman, Kevin; Belikov, Ruslan; Pluzhnik, Eugene; Balasubramanian, Kunjithapatham; Wilson, Dan
2014-01-01
Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.
Contrast Gain Control Model Fits Masking Data
NASA Technical Reports Server (NTRS)
Watson, Andrew B.; Solomon, Joshua A.; Null, Cynthia H. (Technical Monitor)
1994-01-01
We studied the fit of a contrast gain control model to data of Foley (JOSA 1994), consisting of thresholds for a Gabor patch masked by gratings of various orientations, or by compounds of two orientations. Our general model includes models of Foley and Teo & Heeger (IEEE 1994). Our specific model used a bank of Gabor filters with octave bandwidths at 8 orientations. Excitatory and inhibitory nonlinearities were power functions with exponents of 2.4 and 2. Inhibitory pooling was broad in orientation, but narrow in spatial frequency and space. Minkowski pooling used an exponent of 4. All of the data for observer KMF were well fit by the model. We have developed a contrast gain control model that fits masking data. Unlike Foley's, our model accepts images as inputs. Unlike Teo & Heeger's, our model did not require multiple channels for different dynamic ranges.
Ergul, Ayse Betul; Calıskan, Emrah; Samsa, Hasan; Gokcek, Ikbal; Kaya, Ali; Zararsiz, Gozde Erturk; Torun, Yasemin Altuner
2018-06-18
The effectiveness of using a face mask with a small diffuser for oxygen delivery (OxyMask) was compared to use of a high-flow nasal cannula (HFNC) in patients with moderate or severe bronchiolitis.The study population in this open, phase 4, randomized controlled trial consisted of 60 patients aged 1-24 months diagnosed with moderate or severe bronchiolitis and admitted to an intensive care unit (ICU) for oxygen therapy. The patients were randomized into two groups according to the method of oxygen delivery: a diffuser mask group and an HFNC group.There were seven failures in the mask group and none in the HFNC group. The survival probability differed significantly between the two treatment methods (p = 0.009).Time to weaning off oxygen therapy was 56 h in the HFNC group and 96 h in the mask group (p < 0.001). HFNC use decreased the treatment failure rate and the duration of both oxygen therapy and ICU treatment compared to the diffuser mask, which implies that an HFNC should be the first choice for treating patients admitted to the ICU with severe bronchiolitis. What is known: • A high-flow nasal cannula (HFNC) does not significantly reduce the time on oxygen compared to standard therapy in children with moderate to severe bronchiolitis. Observational studies show that, since the introduction of HFNC, fewer children with bronchiolitis need intubation. For children with moderate to severe bronchiolitis there is no proof of its benefit. What Is New: • In children with moderate to severe bronchiolitis, HFNC provides faster and more effective improvement than can be achieved with a diffuser mask.
Face mask use by patients in primary care.
Tischendorf, Jessica S; Temte, Jonathan L
2012-02-01
Face masks are recommended for patients with respiratory symptoms to reduce influenza transmission. Little knowledge exists regarding actual utilization and acceptance of face masks in primary care. Compare distribution of face masks to clinic and community trends in respiratory infection (RI) and influenza-like illness (ILI); estimate the annual need for face masks in primary care. Retrospective observational study of practice data from a 31-week period starting in October 2009. Family practice clinic in Madison, Wis. Patients with fever, cough, or other respiratory symptoms as evaluated by reception staff. Age, sex, and weekly counts of individuals receiving a face mask, as well as counts of RI and ILI patients based on ICD-9 coding from 27 statewide clinics. Face mask counts were 80% of RI counts for the clinic and reflected the demographics of the clinic population. Distribution was correlated to prevalence of RI (R = 0.783, P < 0.001) and ILI (R = 0.632, P < 0.001). Annually, 8% of clinic visits were for RI. The high percentage of face mask use among RI patients reflects the feasibility of this intervention to help control influenza transmission in a primary care setting. Using the present data, clinics can estimate the annual need for face masks.
Ng, Justin R.; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G.; Chai-Coetzer, Ching Li; McEvoy, R. Doug; Antic, Nick
2016-01-01
Study Objectives: The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. Methods: We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. Results: The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m2) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. Conclusions: If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Ng JR, Aiyappan V, Mercer J, Catcheside PG, Chai-Coetzer CL, McEvoy RD, Antic N. Choosing an oronasal mask to deliver continuous positive airway pressure may cause more upper airway obstruction or lead to higher continuous positive airway pressure requirements than a nasal mask in some patients: a case series. J Clin Sleep Med 2016;12(9):1227–1232. PMID:27306398
MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi
2016-12-30
Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. 6 major hospitals in 2 districts of Beijing, China. Cluster randomised controlled trial. 245 index cases with ILI. Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. ACTRN12613000852752; Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
MacIntyre, Chandini Raina; Zhang, Yi; Chughtai, Abrar Ahmad; Seale, Holly; Zhang, Daitao; Chu, Yanhui; Zhang, Haiyan; Rahman, Bayzidur; Wang, Quanyi
2016-01-01
Rationale Medical masks are commonly used by sick individuals with influenza-like illness (ILI) to prevent spread of infections to others, but clinical efficacy data are absent. Objective Determine whether medical mask use by sick individuals with ILI protects well contacts from related respiratory infections. Setting 6 major hospitals in 2 districts of Beijing, China. Design Cluster randomised controlled trial. Participants 245 index cases with ILI. Intervention Index cases with ILI were randomly allocated to medical mask (n=123) and control arms (n=122). Since 43 index cases in the control arm also used a mask during the study period, an as-treated post hoc analysis was performed by comparing outcomes among household members of index cases who used a mask (mask group) with household members of index cases who did not use a mask (no-mask group). Main outcome measure Primary outcomes measured in household members were clinical respiratory illness, ILI and laboratory-confirmed viral respiratory infection. Results In an intention-to-treat analysis, rates of clinical respiratory illness (relative risk (RR) 0.61, 95% CI 0.18 to 2.13), ILI (RR 0.32, 95% CI 0.03 to 3.13) and laboratory-confirmed viral infections (RR 0.97, 95% CI 0.06 to 15.54) were consistently lower in the mask arm compared with control, although not statistically significant. A post hoc comparison between the mask versus no-mask groups showed a protective effect against clinical respiratory illness, but not against ILI and laboratory-confirmed viral respiratory infections. Conclusions The study indicates a potential benefit of medical masks for source control, but is limited by small sample size and low secondary attack rates. Larger trials are needed to confirm efficacy of medical masks as source control. Trial registration number ACTRN12613000852752; Results. PMID:28039289
NASA Astrophysics Data System (ADS)
Mamezaki, Daiki; Harada, Tetsuo; Nagata, Yutaka; Watanabe, Takeo
2017-07-01
In extreme ultraviolet (EUV) lithography, development of review tools for EUV mask pattern and phase defect at working wavelength of 13.5 nm is required. The EUV mask is composed of an absorber pattern (50 - 70 nm thick) and Mo/Si multilayer (280 nm thick) on a glass substrate. This mask pattern seems three-dimensional (3D) structure. This 3D structure would modulate EUV reflection phase, which would cause focus and pattern shifts. Thus, EUV phase imaging is important to evaluate this phase modulation. We have developed coherent EUV scatterometry microscope (CSM), which is a simple microscope without objective optics. EUV phase and intensity image are reconstructed with diffraction images by ptychography with coherent EUV illumination. The high-harmonic-generation (HHG) EUV source was employed for standalone CSM system. In this study, we updated HHG system of pump-laser reduction and gas-pressure control. Two types of EUV mask absorber patterns were observed. An 88-nm lines-and-spaces and a cross-line patterns were clearly reconstructed by ptychography. In addition, a natural defect with 2-μm diameter on the cross-line was well reconstructed. This demonstrated the high capability of the standalone CSM, which system will be used in the factories, such as mask shops and semiconductor fabrication plants.
Development for 2D pattern quantification method on mask and wafer
NASA Astrophysics Data System (ADS)
Matsuoka, Ryoichi; Mito, Hiroaki; Toyoda, Yasutaka; Wang, Zhigang
2010-03-01
We have developed the effective method of mask and silicon 2-dimensional metrology. The aim of this method is evaluating the performance of the silicon corresponding to Hotspot on a mask. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. 2-dimensional Shape quantification is important as optimal solution over these problems. Although 1-dimensional shape measurement has been performed by the conventional technique, 2-dimensional shape management is needed in the mass production line under the influence of RET. We developed the technique of analyzing distribution of shape edge performance as the shape management technique. On the other hand, there is roughness in the silicon shape made from a mass-production line. Moreover, there is variation in the silicon shape. For this reason, quantification of silicon shape is important, in order to estimate the performance of a pattern. In order to quantify, the same shape is equalized in two dimensions. And the method of evaluating based on the shape is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. It is possible to analyze variability of the edge of the same position with high precision. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. - Estimate of the correlativity of shape variability and a process margin. - Determination of two-dimensional variability of pattern. - Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the shape of the same location of Design, Mask, and Silicon in such a viewpoint.
Syed, Q; Sopwith, W; Regan, M; Bellis, M
2003-01-01
SARS has been called the first global epidemic of the 21st century and has been the cause of a massive and varied public health response in many countries of the world. This report describes observations made by two authors on a journey from Manchester in the United Kingdom to Chiang Mai in Thailand during the peak of global transmission. The public response to SARS, particularly characterised by the wearing of face masks, seemed to outstrip official guidance. Though of uncertain protective benefit, the wearing of masks may have contributed to the awareness of the collective and personal responsibility in combating infectious disease. Active and empowered involvement of the general public in implementing and cooperating with public health control measures supported by national and international authorities has clearly helped to bring SARS under control. The public health significance of such potent symbols as the face mask may be considered in strategies to tackle other emerging infections. PMID:14600109
Allely, Rebekah R; Van-Buendia, Lan B; Jeng, James C; White, Patricia; Wu, Jingshu; Niszczak, Jonathan; Jordan, Marion H
2008-01-01
A paradigm shift in management of postburn facial scarring is lurking "just beneath the waves" with the widespread availability of two recent technologies: precise three-dimensional scanning/digitizing of complex surfaces and computer-controlled rapid prototyping three-dimensional "printers". Laser Doppler imaging may be the sensible method to track the scar hyperemia that should form the basis of assessing progress and directing incremental changes in the digitized topographical face mask "prescription". The purpose of this study was to establish feasibility of detecting perfusion through transparent face masks using the Laser Doppler Imaging scanner. Laser Doppler images of perfusion were obtained at multiple facial regions on five uninjured staff members. Images were obtained without a mask, followed by images with a loose fitting mask with and without a silicone liner, and then with a tight fitting mask with and without a silicone liner. Right and left oblique images, in addition to the frontal images, were used to overcome unobtainable measurements at the extremes of face mask curvature. General linear model, mixed model, and t tests were used for data analysis. Three hundred seventy-five measurements were used for analysis, with a mean perfusion unit of 299 and pixel validity of 97%. The effect of face mask pressure with and without the silicone liner was readily quantified with significant changes in mean cutaneous blood flow (P < .5). High valid pixel rate laser Doppler imager flow data can be obtained through transparent face masks. Perfusion decreases with the application of pressure and with silicone. Every participant measured differently in perfusion units; however, consistent perfusion patterns in the face were observed.
Active membrane masks for improved overlay performance in proximity lithography
NASA Astrophysics Data System (ADS)
Huston, Dryver R.; Plumpton, James; Esser, Brian; Sullivan, Gerald A.
2004-07-01
Membrane masks are thin (2 micron x 35 mm x 35 mm) structures that carry the master exposure patterns in proximity (X-ray) lithography. With the continuous drive to the printing of ever-finer features in microelectronics, the reduction of mask-wafer overlay positioning errors by passive rigid body positioning and passive stress control in the mask becomes impractical due to nano and sub-micron scale elastic deformations in the membrane mask. This paper describes the design, mechanics and performance of a system for actively stretching a membrane mask in-plane to control overlay distortion. The method uses thermoelectric heating/cooling elements placed on the mask perimeter. The thermoelectric elements cause controlled thermoelastic deformations in the supporting wafer, which in turn corrects distortions in the membrane mask. Silicon carbide masks are the focus of this study, but the method is believed to be applicable to other mask materials, such as diamond. Experimental and numerical results will be presented, as well as a discussion of the design issues and related design decisions.
Ng, Justin R; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G; Chai-Coetzer, Ching Li; McEvoy, R Doug; Antic, Nick
2016-09-15
The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m(2)) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.
Respiratory source control using a surgical mask: An in vitro study.
Patel, Rajeev B; Skaria, Shaji D; Mansour, Mohamed M; Smaldone, Gerald C
2016-07-01
Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an "N95 respirator") with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection.
The role of lines and corners of geometric figures in recognition performance.
Shevelev, Igor A; Kamenkovich, Viktorina M; Sharaev, George A
2003-01-01
A relative role of lines and corners of images of outline geometric figures in recognition performance was studied psychophysically. Probability of correct response to the shape of the whole figure (control) and figures with lines or corners masked to a different extent was compared. Increase in the extent of masking resulted in a drop of recognition performance that was significantly lower for figures without corners, than for figures without part of their lines. The whole 3D figures were recognized better than 2D ones, whereas the opposite relations were observed under conditions of masking. Significant gender difference in a recognition performance was found: men recognize entire and partly masked figures better than women. Possible mechanisms of relatively better recognition of figures with corners than with lines are discussed in connection with finding of high sensitivity of many neurons in the primary visual cortex to line crossing and branching.
Yam, Man-Ching; So, Hung-Kwan; Kwok, Sit-Yee; Lo, Fung-Cheung; Mok, Chi-Fung; Leung, Chuk-Kwan; Yip, Wai-Kwok; Sung, Yn-Tz
2018-06-01
In our previous study, the prevalence of childhood masked hypertension was 11%. This study aims to assess the left ventricular mass index of persistent masked hypertension and determine the factors of elevated left ventricular mass index in Hong Kong Chinese adolescents from a community cohort. Community prospective cohort study, follow-up of a case-control study in community. Patients with masked hypertension at baseline were invited to recheck ambulatory blood pressure for the persistence of masked hypertension. A total of 144 out of 165 patients with masked hypertension in the 2011/2012 ambulatory blood pressure survey consented to participate in the study. In all, 48 patients were found to have persistent masked hypertension by ambulatory blood pressure rechecking and were matched with normotensive controls by sex, age, and body height. The left ventricular mass (117.3±39.9 g versus 87.0±28.2 g versus 102.0±28.2 g) and left ventricular mass index (30.1±8.4 g/m2.7 versus 23.9±6.3 g/m2.7 versus 25.1±5.7 g/m2.7) were significantly higher in the persistent masked hypertension group (p<0.0001) compared with the patients without persistent masked hypertension and controls. In multivariate linear regression analysis, left ventricular mass index was found to be higher in male gender (β=4.874, p<0.0001) and the patients with persistent masked hypertension (β=2.796, p=0.003). In addition, left ventricular mass index was positively associated with body mass index z-score (β=3.045, p<0.0001) and low-density lipoprotein cholesterol concentration (β=1.634, p=0.015). Persistent masked hypertension in adolescents is associated with elevated left ventricular mass index.
Preserved subliminal processing and impaired conscious access in schizophrenia
Del Cul, Antoine; Dehaene, Stanislas; Leboyer, Marion
2006-01-01
Background Studies of visual backward masking have frequently revealed an elevated masking threshold in schizophrenia. This finding has frequently been interpreted as indicating a low-level visual deficit. However, more recent models suggest that masking may also involve late and higher-level integrative processes, while leaving intact early “bottom-up” visual processing. Objectives We tested the hypothesis that the backward masking deficit in schizophrenia corresponds to a deficit in the late stages of conscious perception, whereas the subliminal processing of masked stimuli is fully preserved. Method 28 patients with schizophrenia and 28 normal controls performed two backward-masking experiments. We used Arabic digits as stimuli and varied quasi-continuously the interval with a subsequent mask, thus allowing us to progressively “unmask” the stimuli. We finely quantified their degree of visibility using both objective and subjective measures to evaluate the threshold duration for access to consciousness. We also studied the priming effect caused by the variably masked numbers on a comparison task performed on a subsequently presented and highly visible target number. Results The threshold delay between digit and mask necessary for the conscious perception of the masked stimulus was longer in patients compared to control subjects. This higher consciousness threshold in patients was confirmed by an objective and a subjective measure, and both measures were highly correlated for patients as well as for controls. However, subliminal priming of masked numbers was effective and identical in patients compared to controls. Conclusions Access to conscious report of masked stimuli is impaired in schizophrenia, while fast bottom-up processing of the same stimuli, as assessed by subliminal priming, is preserved. These findings suggest a high-level origin of the masking deficit in schizophrenia, although they leave open for further research its exact relation to previously identified bottom-up visual processing abnormalities. PMID:17146006
Effect of Masked Regions on Weak-lensing Statistics
NASA Astrophysics Data System (ADS)
Shirasaki, Masato; Yoshida, Naoki; Hamana, Takashi
2013-09-01
Sky masking is unavoidable in wide-field weak-lensing observations. We study how masks affect the measurement of statistics of matter distribution probed by weak gravitational lensing. We first use 1000 cosmological ray-tracing simulations to examine in detail the impact of masked regions on the weak-lensing Minkowski Functionals (MFs). We consider actual sky masks used for a Subaru Suprime-Cam imaging survey. The masks increase the variance of the convergence field and the expected values of the MFs are biased. The bias then compromises the non-Gaussian signals induced by the gravitational growth of structure. We then explore how masks affect cosmological parameter estimation. We calculate the cumulative signal-to-noise ratio (S/N) for masked maps to study the information content of lensing MFs. We show that the degradation of S/N for masked maps is mainly determined by the effective survey area. We also perform simple χ2 analysis to show the impact of lensing MF bias due to masked regions. Finally, we compare ray-tracing simulations with data from a Subaru 2 deg2 survey in order to address if the observed lensing MFs are consistent with those of the standard cosmology. The resulting χ2/n dof = 29.6/30 for three combined MFs, obtained with the mask effects taken into account, suggests that the observational data are indeed consistent with the standard ΛCDM model. We conclude that the lensing MFs are a powerful probe of cosmology only if mask effects are correctly taken into account.
Functional neuroanatomy of visual masking deficits in schizophrenia.
Green, Michael F; Lee, Junghee; Cohen, Mark S; Engel, Steven A; Korb, Alexander S; Nuechterlein, Keith H; Wynn, Jonathan K; Glahn, David C
2009-12-01
Visual masking procedures assess the earliest stages of visual processing. Patients with schizophrenia reliably show deficits on visual masking, and these procedures have been used to explore vulnerability to schizophrenia, probe underlying neural circuits, and help explain functional outcome. To identify and compare regional brain activity associated with one form of visual masking (ie, backward masking) in schizophrenic patients and healthy controls. Subjects received functional magnetic resonance imaging scans. While in the scanner, subjects performed a backward masking task and were given 3 functional localizer activation scans to identify early visual processing regions of interest (ROIs). University of California, Los Angeles, and the Department of Veterans Affairs Greater Los Angeles Healthcare System. Nineteen patients with schizophrenia and 19 healthy control subjects. Main Outcome Measure The magnitude of the functional magnetic resonance imaging signal during backward masking. Two ROIs (lateral occipital complex [LO] and the human motion selective cortex [hMT+]) showed sensitivity to the effects of masking, meaning that signal in these areas increased as the target became more visible. Patients had lower activation than controls in LO across all levels of visibility but did not differ in other visual processing ROIs. Using whole-brain analyses, we also identified areas outside the ROIs that were sensitive to masking effects (including bilateral inferior parietal lobe and thalamus), but groups did not differ in signal magnitude in these areas. The study results support a key role in LO for visual masking, consistent with previous studies in healthy controls. The current results indicate that patients fail to activate LO to the same extent as controls during visual processing regardless of stimulus visibility, suggesting a neural basis for the visual masking deficit, and possibly other visual integration deficits, in schizophrenia.
Altered affective response in marijuana smokers: an FMRI study.
Gruber, Staci A; Rogowska, Jadwiga; Yurgelun-Todd, Deborah A
2009-11-01
More than 94 million Americans have tried marijuana, and it remains the most widely used illicit drug in the nation. Investigations of the cognitive effects of marijuana report alterations in brain function during tasks requiring executive control, including inhibition and decision-making. Endogenous cannabinoids regulate a variety of emotional responses, including anxiety, mood control, and aggression; nevertheless, little is known about smokers' responses to affective stimuli. The anterior cingulate and amygdala play key roles in the inhibition of impulsive behavior and affective regulation, and studies using PET and fMRI have demonstrated changes within these regions in marijuana smokers. Given alterations in mood and perception often observed in smokers, we hypothesized altered fMRI patterns of response in 15 chronic heavy marijuana smokers relative to 15 non-marijuana smoking control subjects during the viewing of masked happy and fearful faces. Despite no between-group differences on clinical or demographic measures, smokers demonstrated a relative decrease in both anterior cingulate and amygdalar activity during masked affective stimuli compared to controls, who showed relative increases in activation within these regions during the viewing of masked faces. Findings indicate that chronic heavy marijuana smokers demonstrate altered activation of frontal and limbic systems while viewing masked faces, consistent with autoradiographic studies reporting high CB-1 receptor density in these regions. These data suggest differences in affective processing in chronic smokers, even when stimuli are presented below the level of conscious processing, and underscore the likelihood that marijuana smokers process emotional information differently from those who do not smoke, which may result in negative consequences.
Respiratory source control using a surgical mask: An in vitro study
Patel, Rajeev B.; Skaria, Shaji D.; Mansour, Mohamed M.; Smaldone, Gerald C.
2016-01-01
ABSTRACT Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an “N95 respirator”) with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection. PMID:26225807
A mask quality control tool for the OSIRIS multi-object spectrograph
NASA Astrophysics Data System (ADS)
López-Ruiz, J. C.; Vaz Cedillo, Jacinto Javier; Ederoclite, Alessandro; Bongiovanni, Ángel; González Escalera, Víctor
2012-09-01
OSIRIS multi object spectrograph uses a set of user-customised-masks, which are manufactured on-demand. The manufacturing process consists of drilling the specified slits on the mask with the required accuracy. Ensuring that slits are on the right place when observing is of vital importance. We present a tool for checking the quality of the process of manufacturing the masks which is based on analyzing the instrument images obtained with the manufactured masks on place. The tool extracts the slit information from these images, relates specifications with the extracted slit information, and finally communicates to the operator if the manufactured mask fulfills the expectations of the mask designer. The proposed tool has been built using scripting languages and using standard libraries such as opencv, pyraf and scipy. The software architecture, advantages and limits of this tool in the lifecycle of a multiobject acquisition are presented.
EFFECT OF MASKED REGIONS ON WEAK-LENSING STATISTICS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shirasaki, Masato; Yoshida, Naoki; Hamana, Takashi, E-mail: masato.shirasaki@utap.phys.s.u-tokyo.ac.jp
2013-09-10
Sky masking is unavoidable in wide-field weak-lensing observations. We study how masks affect the measurement of statistics of matter distribution probed by weak gravitational lensing. We first use 1000 cosmological ray-tracing simulations to examine in detail the impact of masked regions on the weak-lensing Minkowski Functionals (MFs). We consider actual sky masks used for a Subaru Suprime-Cam imaging survey. The masks increase the variance of the convergence field and the expected values of the MFs are biased. The bias then compromises the non-Gaussian signals induced by the gravitational growth of structure. We then explore how masks affect cosmological parameter estimation.more » We calculate the cumulative signal-to-noise ratio (S/N) for masked maps to study the information content of lensing MFs. We show that the degradation of S/N for masked maps is mainly determined by the effective survey area. We also perform simple {chi}{sup 2} analysis to show the impact of lensing MF bias due to masked regions. Finally, we compare ray-tracing simulations with data from a Subaru 2 deg{sup 2} survey in order to address if the observed lensing MFs are consistent with those of the standard cosmology. The resulting {chi}{sup 2}/n{sub dof} = 29.6/30 for three combined MFs, obtained with the mask effects taken into account, suggests that the observational data are indeed consistent with the standard {Lambda}CDM model. We conclude that the lensing MFs are a powerful probe of cosmology only if mask effects are correctly taken into account.« less
Gurwin, Jaclyn; Revere, Karen E; Niepold, Suzannah; Bassett, Barbara; Mitchell, Rebecca; Davidson, Stephanie; DeLisser, Horace; Binenbaum, Gil
2018-01-01
Observation and description are critical to the practice of medicine, and to ophthalmology in particular. However, medical education does not provide explicit training in these areas, and medical students are often criticized for deficiencies in these skills. We sought to evaluate the effects of formal observation training in the visual arts on the general and ophthalmologic observational skills of medical students. Randomized, single-masked, controlled trial. Thirty-six first-year medical students, randomized 1:1 into art-training and control groups. Students in the art-training group were taught by professional art educators at the Philadelphia Museum of Art, during 6 custom-designed, 1.5-hour art observation sessions over a 3-month period. All subjects completed pre- and posttesting, in which they described works of art, retinal pathology images, and external photographs of eye diseases. Grading of written descriptions for observational and descriptive abilities by reviewers using an a priori rubric and masked to group assignment and pretesting/posttesting status. Observational skills, as measured by description testing, improved significantly in the training group (mean change +19.1 points) compared with the control group (mean change -13.5 points), P = 0.001. There were significant improvements in the training vs. control group for each of the test subscores. In a poststudy questionnaire, students reported applying the skills they learned in the museum in clinically meaningful ways at medical school. Art observation training for first-year medical students can improve clinical ophthalmology observational skills. Principles from the field of visual arts, which is reputed to excel in teaching observation and descriptive abilities, can be successfully applied to medical training. Further studies can examine the impact of such training on clinical care. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Does conflict control occur without awareness? Evidence from an ERP study.
Wang, Baoxi; Xiang, Ling; Li, Juan
2013-01-15
The relationship between conflict control and awareness has attracted extensive interest. Although researchers have investigated the relationship between response conflict and awareness, it still remains unclear whether stimulus conflict can occur outside of awareness. In addition, previous studies on the role of awareness in conflict control have ignored the fact that conflict control includes both conflict detection and resolution. A modified version of the flanker task was used to manipulate stimulus and response conflicts under both masked and unmasked conditions. The masked condition elicited a sequence of distinct event-related potential components that were also observed in the unmasked condition. N2 amplitudes presented the following pattern: incongruent-eligible>incongruent-ineligible>congruent, they did not show any difference under the masked and unmasked conditions, suggesting that detection of stimulus-related conflict revealed by the comparison between incongruent-ineligible and congruent trials, and response-related conflict revealed by the comparison between incongruent-eligible and incongruent-ineligible trials can occur in the absence of awareness, and unconscious conflict detection might involve the same neural network employed for conscious conflict detection. Late positive component (LPC) amplitudes also presented as incongruent-eligible>incongruent-ineligible>congruent at CPz and Pz, irrespective of conscious awareness. However, LPC amplitudes under the masked condition were markedly reduced compared to unmasked trials. These LPC findings suggest that stimulus- and response-related conflict resolution can occur in the absence of awareness; furthermore, unconscious conflict resolution might involve a weaker cognitive control network compared to conscious conflict resolution. These findings have important implications for the theories concerning the relationship between cognitive control and awareness. Copyright © 2012 Elsevier B.V. All rights reserved.
Masking with faces in central visual field under a variety of temporal schedules.
Daar, Marwan; Wilson, Hugh R
2015-11-01
With a few exceptions, previous studies have explored masking using either a backward mask or a common onset trailing mask, but not both. In a series of experiments, we demonstrate the use of faces in central visual field as a viable method to study the relationship between these two types of mask schedule. We tested observers in a two alternative forced choice face identification task, where both target and mask comprised synthetic faces, and show that a simple model can successfully predict masking across a variety of masking schedules ranging from a backward mask to a common onset trailing mask and a number of intermediate variations. Our data are well accounted for by a window of sensitivity to mask interference that is centered at around 100 ms. Copyright © 2015 Elsevier Ltd. All rights reserved.
Luiga, I; Bachmann, T
2007-11-01
Enns and Di Lollo [Psychological Science, 8 (2), 135-139, 1997] have introduced the object substitution theory of visual masking. Object substitution masking occurs when focusing attention on the target is delayed. However, Posner (Quarterly Journal of Experimental Psychology, 32, 3-25, 1980) has already shown that attention can be directed to a target at least in two ways: intentionally (endogenously) and automatically (exogenously). We conducted two experiments to explore the effects of endogenous and exogenous cues on substitution masking. The results showed that when attention was shifted to the target location automatically (using a local peripheral pre-cue), masking was attenuated. A decrease in target identification dependent on a delay of mask offset, typical to substitution masking, was not observed. However, strong substitution masking occurred when the target location was not pre-cued or when attention was directed to the target location intentionally (using a symbolic pre-cue displayed centrally). The hypothesis of two different mechanisms of attentional control in substitution masking was confirmed.
The role of auditory and kinaesthetic feedback mechanisms on phonatory stability in children.
Rathna Kumar, S B; Azeem, Suhail; Choudhary, Abhishek Kumar; Prakash, S G R
2013-12-01
Auditory feedback plays an important role in phonatory control. When auditory feedback is disrupted, various changes are observed in vocal motor control. Vocal intensity and fundamental frequency (F0) levels tend to increase in response to auditory masking. Because of the close reflexive links between the auditory and phonatory systems, it is likely that phonatory stability may be disrupted when auditory feedback is disrupted or altered. However, studies on phonatory stability under auditory masking condition in adult subjects showed that most of the subjects maintained normal levels of phonatory stability. The authors in the earlier investigations suggested that auditory feedback is not the sole contributor to vocal motor control and phonatory stability, a complex neuromuscular reflex system known as kinaesthetic feedback may play a role in controlling phonatory stability when auditory feedback is disrupted or lacking. This proposes the need to further investigate this phenomenon as to whether children show similar patterns of phonatory stability under auditory masking since their neuromotor systems are still at developmental stage, less mature and are less resistant to altered auditory feedback than adults. A total of 40 normal hearing and speaking children (20 male and 20 female) between the age group of 6 and 8 years participated as subjects. The acoustic parameters such as shimmer, jitter and harmonic-to-noise ratio (HNR) were measures and compared between no masking condition (0 dB ML) and masking condition (90 dB ML). Despite the neuromotor systems being less mature in children and less resistant than adults to altered auditory feedback, most of the children in the study demonstrated increased phonatory stability which was reflected by reduced shimmer, jitter and increased HNR values. This study implicates that most of the children demonstrate well established patterns of kinaesthetic feedback, which might have allowed them to maintain normal levels of vocal motor control even in the presence of disturbed auditory feedback. Hence, it can be concluded that children also exhibit kinaesthetic feedback mechanism to control phonatory stability when auditory feedback is disrupted which in turn highlights the importance of kinaesthetic feedback to be included in the therapeutic/intervention approaches for children with hearing and neurogenic speech deficits.
Facemasks, Hand Hygiene, and Influenza among Young Adults: A Randomized Intervention Trial
Aiello, Allison E.; Perez, Vanessa; Coulborn, Rebecca M.; Davis, Brian M.; Uddin, Monica; Monto, Arnold S.
2012-01-01
Limited vaccine availability and the potential for resistance to antiviral medications have led to calls for establishing the efficacy of non-pharmaceutical measures for mitigating pandemic influenza. Our objective was to examine if the use of face masks and hand hygiene reduced rates of influenza-like illness (ILI) and laboratory-confirmed influenza in the natural setting. A cluster-randomized intervention trial was designed involving 1,178 young adults living in 37 residence houses in 5 university residence halls during the 2007–2008 influenza season. Participants were assigned to face mask and hand hygiene, face mask only, or control group during the study. Discrete-time survival models using generalized estimating equations to estimate intervention effects on ILI and confirmed influenza A/B infection over a 6-week study period were examined. A significant reduction in the rate of ILI was observed in weeks 3 through 6 of the study, with a maximum reduction of 75% during the final study week (rate ratio [RR] = 0.25, [95% CI, 0.07 to 0.87]). Both intervention groups compared to the control showed cumulative reductions in rates of influenza over the study period, although results did not reach statistical significance. Generalizability limited to similar settings and age groups. Face masks and hand hygiene combined may reduce the rate of ILI and confirmed influenza in community settings. These non-pharmaceutical measures should be recommended in crowded settings at the start of an influenza pandemic. Trail Registration Clinicaltrials.gov NCT00490633 PMID:22295066
Photodetectors on Coronagraph Mask for Pointing Control
NASA Technical Reports Server (NTRS)
Balasubramanian, Kunjithapatham
2007-01-01
It has been proposed to install a symmetrical array of photodetectors about the center of the mask of a coronagraph of the type used to search for planets orbiting remote stars. The purpose of this installation is to utilize the light from a star under observation as a guide in pointing the telescope. Simple arithmetic processing of the outputs of the photodetectors would provide indications of the lateral position of the center of the mask relative to the center of the image of the star. These indications could serve as pointing-control feedback signals for adjusting the telescope aim to center the image of the star on the mask. The widths of central mask areas available for placement of photodetectors differ among coronagraph designs, typically ranging upward from about 100 m. Arrays of photodetectors can readily be placed within areas in this size range. The number of detectors in an array could be as small as 4 or as large as 64. The upper limit on the number of detectors would be determined according to the extent of the occulting pattern and the number of functionalities, in addition to pointing control, to be served by the array.
A cluster randomised trial of cloth masks compared with medical masks in healthcare workers
MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi
2015-01-01
Objective The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. Setting 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. Participants 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Intervention Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Main outcome measure Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. Results The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. Conclusions This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Trial registration number Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. PMID:25903751
Winter, Susan; Thomas, Jane H; Stephens, Dianne P; Davis, Joshua S
2010-03-01
To determine the proportion of hospital staff who pass fit tests with each of three commonly used particulate face masks, and factors influencing preference and fit test results. Observational study. 50 healthy hospital staff volunteers in an 18-bed general intensive care unit in an Australian teaching hospital. Participants were administered a questionnaire about mask use and their preferred mask and underwent qualitative fit-testing with each of three different particulate masks: Kimberly-Clark Tecnol FluidShield N95 particulate filter respirator (KC), 3M Flat Fold 9320 particulate respirator and 3M 8822 particulate respirator with exhalation valve. Participants who failed fittesting were trained in correct mask donning, and fittesting was repeated. Proportion of participants who passed the fit test for each mask and the effect of training. The proportion of participants who passed a fit test was low for all three masks tested (KC, 16%; flat fold, 28%; and valved, 34%). Rates improved after training: the first mask tested fitted in 18% of participants pre-training and 40% post-training (P = 0.02). None of the masks fitted for 28% of participants. There were no significant predictors of fit-test results. A large proportion of individuals failed a fit test with any given mask, and we were not able to identify any factors that predicted mask fit in individuals. Training on mask use improved the rates of adequate fit. Hospitals should carry a range of P2 masks, and should conduct systematic P2 mask training and fit-testing programs for all staff potentially exposed to airborne pathogens.
Photorefractive keratectomy at 193 nm using an erodible mask
NASA Astrophysics Data System (ADS)
Gordon, Michael; Brint, Stephen F.; Durrie, Daniel S.; Seiler, Theo; Friedman, Marc D.; Johnsson, N. M. F.; King, Michael C.; Muller, David F.
1992-08-01
Clinical experience with more than ten thousand sighted eyes has demonstrated great promise for correcting myopia with photorefractive keratectomy (PRK). Previously reported techniques have incorporated computer-controlled irises, diaphragms, and apertures to regulate the desired distribution of 193 nm radiation onto the eye. This paper reports on an entirely new approach for performing PRK which utilizes an erodible mask to control the shape transfer process. Compared to the more traditional techniques, the erodible mask offers promise of correcting a broad range of refractive errors. In this paper the erodible mask and associated hardware are described in detail. We describe the shape transfer experiments used to predict the functional relationship between the desired refractive correction and the mask shape. We report on early clinical results from five patients with myopic astigmatism. We conclude that the early shape transfer experiments overestimated the spherical component of the correction by 1.25 diopters and underestimated the cylindrical component by approximately 0.85 diopters. The data suggest there may be biological effects which evoke different healing responses when myopic PRK corrections are performed with and without astigmatism. Clinical trials are proceeding with the mask shapes adjusted for these observations.
Mukerji, Shohini; MacIntyre, C Raina; Newall, Anthony T
2015-10-13
There has been increasing debate surrounding mask and respirator interventions to control respiratory infection transmission in both healthcare and community settings. As decision makers are considering the recommendations they should evaluate how to provide the most efficient protection strategies with minimum costs. The aim of this review is to identify and evaluate the existing economic evaluation literature in this area and to offer advice on how future evaluations on this topic should be conducted. We searched the Scopus database for all literature on economic evaluation of mask or respirator use to control respiratory infection transmission. Reference lists from the identified studies were also manually searched. Seven studies met our inclusion criteria from the initial 806 studies identified by the search strategy and our manual search. Five studies considered interventions for seasonal and/or pandemic influenza, with one also considering SARS (Severe Acute Respiratory Syndrome). The other two studies focussed on tuberculosis transmission control interventions. The settings and methodologies of the studies varied greatly. No low-middle income settings were identified. Only one of the reviewed studies cited clinical evidence to inform their mask/respirator intervention effectiveness parameters. Mask and respirator interventions were generally reported by the study authors to be cost saving or cost-effective when compared to no intervention or other control measures, however the evaluations had important limitations. Given the large cost differential between masks and respirators, there is a need for more comprehensive economic evaluations to compare the relative costs and benefits of these interventions in situations and settings where alternative options are potentially applicable. There are at present insufficient well conducted cost-effectiveness studies to inform decision-makers on the value for money of alternative mask/respirator options.
Sivaprasad, Sobha; Arden, Geoffrey; Prevost, A Toby; Crosby-Nwaobi, Roxanne; Holmes, Helen; Kelly, Joanna; Murphy, Caroline; Rubin, Gary; Vasconcelos, Joanna; Hykin, Philip
2014-11-22
This study will evaluate hypoxia, as a novel concept in the pathogenesis of diabetic macular oedema (DMO). As the oxygen demand of the eye is maximum during dark-adaptation, we hypothesize that wearing light-masks during sleep will cause regression and prevent the development and progression of DMO. The study protocol comprises both an efficacy and mechanistic evaluation to test this hypothesis. This is a phase III randomised controlled single-masked multicentre clinical trial to test the clinical efficacy of light-masks at preventing dark-adaptation in the treatment of non-central DMO. Three hundred patients with non-centre-involving DMO in at least one eye will be randomised 1:1 to light-masks and control masks (with no light) to be used during sleep at night for a period of 24 months. The primary outcome is regression of non-central oedema by assessing change in the zone of maximal retinal thickness at baseline on optical coherence tomography (SD-OCT). Secondary outcomes will evaluate the prevention of development and progression of DMO by assessing changes in retinal thickness in different regions of the macula, macular volume, refracted visual acuity and level of retinopathy. Safety parameters will include sleep disturbance. Adverse events and measures of compliance will be assessed over 24 months. Participants recruited to the mechanistic sub-study will have additional retinal oximetry, multifocal electroretinography (ERG) and microperimetry to evaluate the role of hypoxia by assessing and comparing changes induced by supplemental oxygen and the light-masks at 12 months. The outcomes of this study will provide insight into the pathogenesis of DMO and provide evidence on whether a simple, non-invasive device in the form of a light-mask can help prevent the progression to centre-involving DMO and visual impairment in people with diabetes.
Gun, Taylan; Özkan, Selçuk; Yavuz, Bunyamin
2018-04-23
Tinnitus is hearing a sound without any external acoustic stimulus. There are some clues of hypertension can cause tinnitus in different ways. The aim of the study was to evaluate the relationship between tinnitus and masked hypertension including echocardiographic parameters and severity of tinnitus. This study included 88 patients with tinnitus of at least 3 months duration and 85 age and gender-matched control subjects. Tinnitus severity index was used to classify the patients with tinnitus. After a complete medical history, all subjects underwent routine laboratory examination, office blood pressure measurement, hearing tests and ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of masked hypertension was significantly higher in patients with tinnitus than controls (18.2% vs 3.5%, p = 0.002). Office diastolic BP (76 ± 8.1 vs. 72.74 ± 8.68, p = 0.01), ambulatory 24-H diastolic BP (70.2 ± 9.6 vs. 66.9 ± 6.1, p = 0.07) and ambulatory daytime diastolic BP (73.7 ± 9.5 vs. 71.1 ± 6.2, p = 0.03) was significantly higher in patients with tinnitus than control group. Tinnitus severity index in patients without masked hypertension was 0 and tinnitus severity index in patients with masked hypertension were 2 (1-5). This study demonstrated that masked hypertension must be kept in mind if there is a complaint of tinnitus without any other obvious reason.
The effect of foveal and parafoveal masks on the eye movements of older and younger readers.
Rayner, Keith; Yang, Jinmian; Schuett, Susanne; Slattery, Timothy J
2014-06-01
In the present study, we examined foveal and parafoveal processing in older compared with younger readers by using gaze-contingent paradigms with 4 conditions. Older and younger readers read sentences in which the text was either a) presented normally, b) the foveal word was masked as soon as it was fixated, c) all of the words to the left of the fixated word were masked, or d) all of the words to the right of the fixated word were masked. Although older and younger readers both found reading when the fixated word was masked quite difficult, the foveal mask increased sentence reading time more than 3-fold (3.4) for the older readers (in comparison with the control condition in which the sentence was presented normally) compared with the younger readers who took 1.3 times longer to read sentences in the foveal mask condition (in comparison with the control condition). The left and right parafoveal masks did not disrupt reading as severely as the foveal mask, though the right mask was more disruptive than the left mask. Also, there was some indication that the younger readers found the right mask condition relatively more disruptive than the left mask condition. PsycINFO Database Record (c) 2014 APA, all rights reserved.
A cluster randomised trial of cloth masks compared with medical masks in healthcare workers.
MacIntyre, C Raina; Seale, Holly; Dung, Tham Chi; Hien, Nguyen Tran; Nga, Phan Thi; Chughtai, Abrar Ahmad; Rahman, Bayzidur; Dwyer, Dominic E; Wang, Quanyi
2015-04-22
The aim of this study was to compare the efficacy of cloth masks to medical masks in hospital healthcare workers (HCWs). The null hypothesis is that there is no difference between medical masks and cloth masks. 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. 1607 hospital HCWs aged ≥18 years working full-time in selected high-risk wards. Hospital wards were randomised to: medical masks, cloth masks or a control group (usual practice, which included mask wearing). Participants used the mask on every shift for 4 consecutive weeks. Clinical respiratory illness (CRI), influenza-like illness (ILI) and laboratory-confirmed respiratory virus infection. The rates of all infection outcomes were highest in the cloth mask arm, with the rate of ILI statistically significantly higher in the cloth mask arm (relative risk (RR)=13.00, 95% CI 1.69 to 100.07) compared with the medical mask arm. Cloth masks also had significantly higher rates of ILI compared with the control arm. An analysis by mask use showed ILI (RR=6.64, 95% CI 1.45 to 28.65) and laboratory-confirmed virus (RR=1.72, 95% CI 1.01 to 2.94) were significantly higher in the cloth masks group compared with the medical masks group. Penetration of cloth masks by particles was almost 97% and medical masks 44%. This study is the first RCT of cloth masks, and the results caution against the use of cloth masks. This is an important finding to inform occupational health and safety. Moisture retention, reuse of cloth masks and poor filtration may result in increased risk of infection. Further research is needed to inform the widespread use of cloth masks globally. However, as a precautionary measure, cloth masks should not be recommended for HCWs, particularly in high-risk situations, and guidelines need to be updated. Australian New Zealand Clinical Trials Registry: ACTRN12610000887077. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Andrade, Rafaela Garcia Santos; Madeiro, Fernanda; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo
2016-11-01
Continuous positive airway pressure (CPAP) delivered by nasal mask is the gold standard treatment for obstructive sleep apnea (OSA). However, oral and oronasal masks are also available. We considered experimental evidence and reviewed clinical trials that evaluated the impact of oral and oronasal mask on OSA treatment. One recent study in 18 OSA patients that slept with a customized oronasal mask with two sealed compartments showed that the change of CPAP flow from nasal to oronasal and oral caused upper airway obstruction because of posterior displacement of the tongue demonstrated by nasoendoscopy. Oral masks use a mouthpiece that may stabilize the jaw and the tongue and have shown to be effective. However, oral masks are not widely used in clinical practice. Four out of five observational studies and all five reviewed randomized studies showed a worse performance of oronasal when compared with nasal masks. Oronasal masks were associated with higher residual apnea-hypopnea index, lower adherence, more leaks, and less satisfaction than nasal mask in the majority of the studies. Nasal CPAP must be the first choice to treat OSA. Patients on oronasal mask should be carefully followed. VIDEO ABSTRACT.
Is Suppression Just Normal Dichoptic Masking? Suprathreshold Considerations.
Reynaud, Alexandre; Hess, Robert F
2016-10-01
Amblyopic patients have a deficit in visual acuity and contrast sensitivity in their amblyopic eye as well as suppression of the amblyopic eye input under binocular viewing conditions. In this study we wanted to assess the origin of the amblyopic suppression by studying the contrast perception of the amblyopic eye at suprathreshold levels under binocular and monocular viewing. Using a suprathreshold contrast matching task in which the reference and target stimuli were presented to different eyes either simultaneously or successively, we measured interocular contrast matching in 10 controls and 11 amblyopes (mean age 35 ± 15; 5 strabismics; 3 anisometropes; 3 mixed). This was then used as an index of the binocular balance across spatial frequency and compared against the contrast sensitivity ratio measured with the same stimuli. We observed that binocular matching becomes more imbalanced at high spatial frequency for amblyopes, compared with controls; that this imbalance did not depend in either group on whether the stimuli were presented simultaneously or successively; and that for both modes of presentation the matching balance correlates well with the interocular contrast sensitivity ratio (mean correlation coefficient of the slopes R = 0.7125). The results from our amblyopes show comparable losses of contrast perception at and above threshold under these binocular viewing conditions across a wide spatial frequency range, much stronger than that observed for our controls. This occurs under conditions in which there should be no dichoptic masking. Furthermore, the matching contrast could be well predicted by the monocular contrast sensitivity. Altogether, this suggests that amblyopic suppression cannot be explained by normal dichoptic masking but rather an attenuation of the input.
Sung, Anthony D; Sung, Julia A M; Thomas, Samantha; Hyslop, Terry; Gasparetto, Cristina; Long, Gwynn; Rizzieri, David; Sullivan, Keith M; Corbet, Kelly; Broadwater, Gloria; Chao, Nelson J; Horwitz, Mitchell E
2016-10-15
Respiratory viral infections (RVIs) are frequent complications of hematopoietic stem cell transplant (HSCT). Surgical masks are a simple and inexpensive intervention that may reduce nosocomial spread. In this prospective single-center study, we instituted a universal surgical mask policy requiring all individuals with direct contact with HSCT patients to wear a surgical mask, regardless of symptoms or season. The primary endpoint was the incidence of RVIs in the mask period (2010-2014) compared with the premask period (2003-2009). RVIs decreased from 10.3% (95/920 patients) in the premask period to 4.4% (40/911) in the mask period (P < .001). Significant decreases occurred after both allogeneic (64/378 [16.9%] to 24/289 [8.3%], P = .001) and autologous (31/542 [5.7%] to 16/622 [2.6%], P = .007) transplants. After adjusting for multiple covariates including season and year in a segmented longitudinal analysis, the decrease in RVIs remained significant, with risk of RVI of 0.4 in patients in the mask group compared with the premask group (0.19-0.85, P = .02). In contrast, no decrease was observed during this same period in an adjacent hematologic malignancy unit, which followed the same infection control practices except for the mask policy. The majority of this decrease was in parainfluenza virus 3 (PIV3) (8.3% to 2.2%, P < .001). Requiring all individuals with direct patient contact to wear a surgical mask is associated with a reduction in RVIs, particularly PIV3, during the most vulnerable period following HSCT. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Sung, Anthony D.; Sung, Julia A. M.; Thomas, Samantha; Hyslop, Terry; Gasparetto, Cristina; Long, Gwynn; Rizzieri, David; Sullivan, Keith M.; Corbet, Kelly; Broadwater, Gloria; Chao, Nelson J.; Horwitz, Mitchell E.
2016-01-01
Background. Respiratory viral infections (RVIs) are frequent complications of hematopoietic stem cell transplant (HSCT). Surgical masks are a simple and inexpensive intervention that may reduce nosocomial spread. Methods. In this prospective single-center study, we instituted a universal surgical mask policy requiring all individuals with direct contact with HSCT patients to wear a surgical mask, regardless of symptoms or season. The primary endpoint was the incidence of RVIs in the mask period (2010–2014) compared with the premask period (2003–2009). Results. RVIs decreased from 10.3% (95/920 patients) in the premask period to 4.4% (40/911) in the mask period (P < .001). Significant decreases occurred after both allogeneic (64/378 [16.9%] to 24/289 [8.3%], P = .001) and autologous (31/542 [5.7%] to 16/622 [2.6%], P = .007) transplants. After adjusting for multiple covariates including season and year in a segmented longitudinal analysis, the decrease in RVIs remained significant, with risk of RVI of 0.4 in patients in the mask group compared with the premask group (0.19–0.85, P = .02). In contrast, no decrease was observed during this same period in an adjacent hematologic malignancy unit, which followed the same infection control practices except for the mask policy. The majority of this decrease was in parainfluenza virus 3 (PIV3) (8.3% to 2.2%, P < .001). Conclusions. Requiring all individuals with direct patient contact to wear a surgical mask is associated with a reduction in RVIs, particularly PIV3, during the most vulnerable period following HSCT. PMID:27481873
Assisted suicide by oxygen deprivation with helium at a Swiss right-to-die organisation.
Ogden, Russel D; Hamilton, William K; Whitcher, Charles
2010-03-01
In Switzerland, right-to-die organisations assist their members with suicide by lethal drugs, usually barbiturates. One organisation, Dignitas, has experimented with oxygen deprivation as an alternative to sodium pentobarbital. To analyse the process of assisted suicide by oxygen deprivation with helium and a common face mask and reservoir bag. This study examined four cases of assisted suicide by oxygen deprivation using helium delivered via a face mask. Videos of the deaths were provided by the Zurich police. Dignitas provided protocol and consent information. One man and three women were assisted to death by oxygen deprivation. There was wide variation in the time to unconsciousness and the time to death, probably due to the poor mask fit. Swiss law prevented attendants from effectively managing the face mask apparatus. Purposeless movements of the extremities were disconcerting for Dignitas attendants, who are accustomed to assisting suicide with barbiturates. None of the dying individuals attempted self-rescue. The dying process of oxygen deprivation with helium is potentially quick and appears painless. It also bypasses the prescribing role of physicians, effectively demedicalising assisted suicide. Oxygen deprivation with a face mask is not acceptable because leaks are difficult to control and it may not eliminate rebreathing. These factors will extend time to unconsciousness and time to death. A hood method could reduce the problem of mask fit. With a hood, a flow rate of helium sufficient to provide continuous washout of expired gases would remedy problems observed with the mask.
Shadows alter facial expressions of Noh masks.
Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo
2013-01-01
A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers' recognition of the emotional expressions. In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa's smile. They also agree with the aesthetic principle of Japanese traditional art "yugen (profound grace and subtlety)", which highly appreciates subtle emotional expressions in the darkness.
Overlay improvement by exposure map based mask registration optimization
NASA Astrophysics Data System (ADS)
Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric
2015-03-01
Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density could also achieve under 5nm performance. We assume mask registration excluding random error is mostly induced by charge accumulation during mask writing, which may be calculated from surrounding exposed pattern density. Multi-loading test mask registration result shows that with x direction writing sequence, mask registration behavior in x direction is mainly related to sequence direction, but mask registration in y direction would be highly impacted by pattern density distribution map. It proves part of mask registration error is due to charge issue from nearby environment. If exposure sequence is chip by chip for normal multi chip layout case, mask registration of both x and y direction would be impacted analogously, which has also been proved by real data. Therefore, we try to set up a simple model to predict the mask registration error based on mask exposure map, and correct it with the given POSCOR (position correction) file for advanced mask writing if needed.
Petersen, Anja S; Barloese, Mads Cj; Lund, Nunu Lt; Jensen, Rigmor H
2017-03-01
Purpose The purpose of this article is to investigate possible differences in effect between three types of masks in the acute treatment of cluster headache (CH). Patients and methods Fifty-seven CH patients according to ICHD-II-criteria participated in a single-blinded, semi-randomized, placebo-controlled, crossover inpatient study, and 102 CH attacks were treated with 100% oxygen delivered by demand valve oxygen (DVO), O 2 ptimask or simple mask (15 liters/min) or placebo delivered by DVO for 15 minutes. Primary endpoint: Two-point decrease of pain on a five-point rating scale within 15 minutes. Results Only 10 CH patients had multiple attacks and reached the point of placebo. There were no significant differences between masks in the primary endpoints ( p = 0.412). After 15 minutes 48% had a two-point decrease using the DVO compared to 45% with placebo ( p = 0.867). After 30 minutes 68% were pain free or had pain relief using DVO and 45% by placebo ( p = 0.061). The DVO was preferred by 62% compared to 5% and 33% for simple mask ( p < 0.0001) and O 2 ptimask ( p = 0.061). In the first attack the DVO was significantly better at achieving pain relief at 15 minutes ( p = 0.018). Treatment with DVO or O 2 ptimask reduced the need for rescue medication compared to the simple mask (23%, 19%, 50%, respectively). No treatment-related adverse events were observed. Conclusion The primary endpoint with pain relief at 15 minutes was non-significant; however, a post hoc analysis of the first attack significantly favored DVO. Further, therapy by O 2 ptimask and DVO resulted in a decreased need for rescue medication. We recommend that CH patients be offered DVO or O 2 ptimask before oxygen therapy is abandoned.
Neuzeret, Pierre-Charles; Morin, Laurent
2017-11-01
Patient interface is important for the success of continuous positive airway pressure (CPAP), but few trials have examined the influence of mask choice on CPAP adherence. To compare the impact of different nasal masks on CPAP in patients with newly-diagnosed obstructive sleep apnea (OSA). OSA patients were randomized in a 2:3 ratio to receive CPAP via different first-line nasal masks: ResMed Mirage FX® (MFX) or control mask (Fisher & Paykel Zest ® , HC407 ® or Philips EasyLife ® ). Mask acceptance, CPAP compliance and Home Care Provider (HCP) interventions were compared between groups after 3 months of CPAP therapy using modified intent-to-treat (mITT; after exclusion of patients with mouth leaks during CPAP initiation) and on-treatment (OT; CPAP adherent) analyses. Of 285 randomized patients, 90 requiring a full-face mask were excluded, leaving 195 and 151 in the mITT and OT analyses, respectively. Mask acceptance rate was higher in the MFX versus control group (mITT: 79% vs 68%, P = 0.067; OT: 90% vs 76%, P = 0.022). CPAP compliance was higher (5.9 ± 1.8 vs 5.1 ± 1.6 h/night, P = 0.011) and nasal mask issue-related HCP visits lower (3% vs 17%, P = 0.006) in the MFX group. Nasal mask failures due to mask discomfort (5% vs 1%) or unintentional leakage (5% vs 0%) were higher in control vs MFX group. Mask acceptance was significantly associated with fewer mask leaks (P = 0.002) and higher pressure therapy (P = 0.042). This study highlights differences between nasal masks for CPAP delivery and shows that initial mask selection can influence adherence and healthcare utilization during CPAP. © 2016 ResMed Germany Inc. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.
Zheng, Yingjun; Wu, Chao; Li, Juanhua; Li, Ruikeng; Peng, Hongjun; She, Shenglin; Ning, Yuping; Li, Liang
2018-04-04
Speech recognition under noisy "cocktail-party" environments involves multiple perceptual/cognitive processes, including target detection, selective attention, irrelevant signal inhibition, sensory/working memory, and speech production. Compared to health listeners, people with schizophrenia are more vulnerable to masking stimuli and perform worse in speech recognition under speech-on-speech masking conditions. Although the schizophrenia-related speech-recognition impairment under "cocktail-party" conditions is associated with deficits of various perceptual/cognitive processes, it is crucial to know whether the brain substrates critically underlying speech detection against informational speech masking are impaired in people with schizophrenia. Using functional magnetic resonance imaging (fMRI), this study investigated differences between people with schizophrenia (n = 19, mean age = 33 ± 10 years) and their matched healthy controls (n = 15, mean age = 30 ± 9 years) in intra-network functional connectivity (FC) specifically associated with target-speech detection under speech-on-speech-masking conditions. The target-speech detection performance under the speech-on-speech-masking condition in participants with schizophrenia was significantly worse than that in matched healthy participants (healthy controls). Moreover, in healthy controls, but not participants with schizophrenia, the strength of intra-network FC within the bilateral caudate was positively correlated with the speech-detection performance under the speech-masking conditions. Compared to controls, patients showed altered spatial activity pattern and decreased intra-network FC in the caudate. In people with schizophrenia, the declined speech-detection performance under speech-on-speech masking conditions is associated with reduced intra-caudate functional connectivity, which normally contributes to detecting target speech against speech masking via its functions of suppressing masking-speech signals.
NASA Astrophysics Data System (ADS)
Prakash, Shashi; Kumar, Subrata
2017-09-01
CO2 lasers are commonly used for fabricating polymer based microfluidic devices. Despite several key advantages like low cost, time effectiveness, easy to operate and no requirement of clean room facility, CO2 lasers suffer from few disadvantages like thermal bulging, improper dimensional control, difficulty to produce microchannels of other than Gaussian cross sectional shapes and inclined surface walls. Many microfluidic devices require square or rectangular cross-sections which are difficult to produce using normal CO2 laser procedures. In this work, a thin copper sheet of 40 μm was used as a mask above the PMMA (Polymethyl-methacrylate) substrate while fabricating the microchannels utilizing the raster scanning feature of the CO2 lasers. Microchannels with different width dimensions were fabricated utilizing a CO2 laser in with mask and without-mask conditions. A comparison of both the fabricating process has been made. It was found that microchannels with U shape cross section and rectangular cross-section can efficiently be produced using the with mask technique. In addition to this, this technique can provide perfect dimensional control and better surface quality of the microchannel walls. Such a microchannel fabrication process do not require any post-processing. The fabrication of mask using a nanosecond fiber laser has been discussed in details. An underwater laser fabrication method was adopted to overcome heat related defects in mask preparation. Overall, the technique was found to be easy to adopt and significant improvements were observed in microchannel fabrication.
Sheppard, James P.; Holder, Roger; Nichols, Linda; Bray, Emma; Hobbs, F.D. Richard; Mant, Jonathan; Little, Paul; Williams, Bryan; Greenfield, Sheila; McManus, Richard J.
2014-01-01
Objectives: Identification of people with lower (white-coat effect) or higher (masked effect) blood pressure at home compared to the clinic usually requires ambulatory or home monitoring. This study assessed whether changes in SBP with repeated measurement at a single clinic predict subsequent differences between clinic and home measurements. Methods: This study used an observational cohort design and included 220 individuals aged 35–84 years, receiving treatment for hypertension, but whose SBP was not controlled. The characteristics of change in SBP over six clinic readings were defined as the SBP drop, the slope and the quadratic coefficient using polynomial regression modelling. The predictive abilities of these characteristics for lower or higher home SBP readings were investigated with logistic regression and repeated operating characteristic analysis. Results: The single clinic SBP drop was predictive of the white-coat effect with a sensitivity of 90%, specificity of 50%, positive predictive value of 56% and negative predictive value of 88%. Predictive values for the masked effect and those of the slope and quadratic coefficient were slightly lower, but when the slope and quadratic variables were combined, the sensitivity, specificity, positive and negative predictive values for the masked effect were improved to 91, 48, 24 and 97%, respectively. Conclusion: Characteristics obtainable from multiple SBP measurements in a single clinic in patients with treated hypertension appear to reasonably predict those unlikely to have a large white-coat or masked effect, potentially allowing better targeting of out-of-office monitoring in routine clinical practice. PMID:25144295
Diameter and location control of ZnO nanowires using electrodeposition and sodium citrate
NASA Astrophysics Data System (ADS)
Lifson, Max L.; Levey, Christopher G.; Gibson, Ursula J.
2013-10-01
We report single-step growth of spatially localized ZnO nanowires of controlled diameter to enable improved performance of piezoelectric devices such as nanogenerators. This study is the first to demonstrate the combination of electrodeposition with zinc nitrate and sodium citrate in the growth solution. Electrodeposition through a thermally-grown silicon oxide mask results in localization, while the growth voltage and solution chemistry are tuned to control the nanowire geometry. We observe a competition between lateral (relative to the (0001) axis) citrate-related morphology and voltage-driven vertical growth which enables this control. High aspect ratios result with either pure nitrate or nitrate-citrate mixtures if large voltages are used, but low growth voltages permit the growth of large diameter nanowires in solution with citrate. Measurements of the current density suggest a two-step growth process. An oxide mask blocks the electrodeposition, and suppresses nucleation of thermally driven growth, permitting single-step lithography on low cost p-type silicon substrates.
Smith, Jeffrey D.; MacDougall, Colin C.; Johnstone, Jennie; Copes, Ray A.; Schwartz, Brian; Garber, Gary E.
2016-01-01
Background: Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. Methods: We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case–control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. Results: We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case–control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64–1.24; cohort study: OR 0.43, 95% CI 0.03–6.41; case–control studies: OR 0.91, 95% CI 0.25–3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19–1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57–1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Interpretation: Although N95 respirators appeared to have a protective advantage over surgical masks in laboratory settings, our meta-analysis showed that there were insufficient data to determine definitively whether N95 respirators are superior to surgical masks in protecting health care workers against transmissible acute respiratory infections in clinical settings. PMID:26952529
Smith, Jeffrey D; MacDougall, Colin C; Johnstone, Jennie; Copes, Ray A; Schwartz, Brian; Garber, Gary E
2016-05-17
Conflicting recommendations exist related to which facial protection should be used by health care workers to prevent transmission of acute respiratory infections, including pandemic influenza. We performed a systematic review of both clinical and surrogate exposure data comparing N95 respirators and surgical masks for the prevention of transmissible acute respiratory infections. We searched various electronic databases and the grey literature for relevant studies published from January 1990 to December 2014. Randomized controlled trials (RCTs), cohort studies and case-control studies that included data on health care workers wearing N95 respirators and surgical masks to prevent acute respiratory infections were included in the meta-analysis. Surrogate exposure studies comparing N95 respirators and surgical masks using manikins or adult volunteers under simulated conditions were summarized separately. Outcomes from clinical studies were laboratory-confirmed respiratory infection, influenza-like illness and workplace absenteeism. Outcomes from surrogate exposure studies were filter penetration, face-seal leakage and total inward leakage. We identified 6 clinical studies (3 RCTs, 1 cohort study and 2 case-control studies) and 23 surrogate exposure studies. In the meta-analysis of the clinical studies, we found no significant difference between N95 respirators and surgical masks in associated risk of (a) laboratory-confirmed respiratory infection (RCTs: odds ratio [OR] 0.89, 95% confidence interval [CI] 0.64-1.24; cohort study: OR 0.43, 95% CI 0.03-6.41; case-control studies: OR 0.91, 95% CI 0.25-3.36); (b) influenza-like illness (RCTs: OR 0.51, 95% CI 0.19-1.41); or (c) reported workplace absenteeism (RCT: OR 0.92, 95% CI 0.57-1.50). In the surrogate exposure studies, N95 respirators were associated with less filter penetration, less face-seal leakage and less total inward leakage under laboratory experimental conditions, compared with surgical masks. Although N95 respirators appeared to have a protective advantage over surgical masks in laboratory settings, our meta-analysis showed that there were insufficient data to determine definitively whether N95 respirators are superior to surgical masks in protecting health care workers against transmissible acute respiratory infections in clinical settings. © 2016 Canadian Medical Association or its licensors.
A pilot study on the use of geometrically accurate face models to replicate ex vivo N95 mask fit.
Golshahi, Laleh; Telidetzki, Karla; King, Ben; Shaw, Diana; Finlay, Warren H
2013-01-01
To test the feasibility of replicating a face mask seal in vitro, we created 5 geometrically accurate reconstructions of the head and neck of an adult human subject using different materials. Three breathing patterns were simulated with each replica and an attached N95 mask. Quantitative fit testing on the subject and the replicas showed that none of the 5 isotropic materials used allowed duplication of the ex vivo mask seal for the specific mask-face combination studied. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Face mask use and control of respiratory virus transmission in households.
MacIntyre, C Raina; Cauchemez, Simon; Dwyer, Dominic E; Seale, Holly; Cheung, Pamela; Browne, Gary; Fasher, Michael; Wood, James; Gao, Zhanhai; Booy, Robert; Ferguson, Neil
2009-02-01
Many countries are stockpiling face masks for use as a nonpharmaceutical intervention to control virus transmission during an influenza pandemic. We conducted a prospective cluster-randomized trial comparing surgical masks, non-fit-tested P2 masks, and no masks in prevention of influenza-like illness (ILI) in households. Mask use adherence was self-reported. During the 2006 and 2007 winter seasons, 286 exposed adults from 143 households who had been exposed to a child with clinical respiratory illness were recruited. We found that adherence to mask use significantly reduced the risk for ILI-associated infection, but <50% of participants wore masks most of the time. We concluded that household use of face masks is associated with low adherence and is ineffective for controlling seasonal respiratory disease. However, during a severe pandemic when use of face masks might be greater, pandemic transmission in households could be reduced.
Effectiveness of activated carbon masks in preventing anticancer drug inhalation.
Sato, Junya; Kogure, Atushi; Kudo, Kenzo
2016-01-01
The exposure of healthcare workers to anticancer drugs such as cyclophosphamide (CPA) is a serious health concern. Anticancer drug pollution may spread outside biological safety cabinets even when a closed system is used. The inhalation of vaporized anticancer drugs is thought to be the primary route of exposure. Therefore, it is important that healthcare workers wear masks to prevent inhalation of anticancer drugs. However, the permeability of medical masks to vaporized anticancer drugs has not been examined. Furthermore, the performance differences between masks including activated carbon with chemical adsorptivity and non-activated carbon masks are uncertain. We investigated activated carbon mask permeability to vaporized CPA, and assessed whether inhibition of vaporized CPA permeability was attributable to the masks' adsorption abilities. A CPA solution (4 mg) was vaporized in a chamber and passed through three types of masks: Pleated-type cotton mask (PCM), pleated-type activated carbon mask (PAM), and stereoscopic-type activated carbon mask (SAM); the flow rate was 1.0 L/min for 1 h. The air was then recovered in 50 % ethanol. CPA quantities in the solution were determined by liquid chromatography time-of-flight mass spectrometry. To determine CPA adsorption by the mask, 5 cm 2 of each mask was immersed in 10 mL of CPA solution (50-2500 μg/mL) for 1 h. CPA concentrations were measured by high-performance liquid chromatography with ultraviolet detection. For the control (no mask), 3.735 ± 0.543 μg of CPA was recovered from the aerated solution. Significantly lower quantities were recovered from PCM (0.538 ± 0.098 μg) and PAM (0.236 ± 0.193 μg) ( p < 0.001 and p < 0.001 vs control, respectively). CPA quantities recovered from all of SAM samples were below the quantification limit. When a piece of the SAM was immersed in the CPA solution, a marked decrease to less than 3.1 % of the initial CPA concentration was observed. The SAM exhibited good adsorption ability, and this characteristic may contribute to avoiding inhalation exposure to vaporized CPA. These results suggest that wearing activated carbon masks may prevent anticancer drug inhalation by healthcare workers.
Hemmesch, Amanda R
2014-09-01
After viewing short video clips of individuals with Parkinson's disease (PD) who varied in the symptoms of facial masking (reduced expressivity) and abnormal bodily movement (ABM: including tremor and related movement disorders), older adult observers provided their first impressions of targets' social positivity. Impressions of targets with higher masking or ABM were more negative than impressions of targets with lower masking or ABM. Furthermore, masking was more detrimental for impressions of women and when observers considered emotional relationship goals, whereas ABM was more detrimental for instrumental relationship goals. This study demonstrated the stigmatizing effects of both reduced and excessive movement. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Dynamics of normalization underlying masking in human visual cortex.
Tsai, Jeffrey J; Wade, Alex R; Norcia, Anthony M
2012-02-22
Stimulus visibility can be reduced by other stimuli that overlap the same region of visual space, a process known as masking. Here we studied the neural mechanisms of masking in humans using source-imaged steady state visual evoked potentials and frequency-domain analysis over a wide range of relative stimulus strengths of test and mask stimuli. Test and mask stimuli were tagged with distinct temporal frequencies and we quantified spectral response components associated with the individual stimuli (self terms) and responses due to interaction between stimuli (intermodulation terms). In early visual cortex, masking alters the self terms in a manner consistent with a reduction of input contrast. We also identify a novel signature of masking: a robust intermodulation term that peaks when the test and mask stimuli have equal contrast and disappears when they are widely different. We fit all of our data simultaneously with family of a divisive gain control models that differed only in their dynamics. Models with either very short or very long temporal integration constants for the gain pool performed worse than a model with an integration time of ∼30 ms. Finally, the absolute magnitudes of the response were controlled by the ratio of the stimulus contrasts, not their absolute values. This contrast-contrast invariance suggests that many neurons in early visual cortex code relative rather than absolute contrast. Together, these results provide a more complete description of masking within the normalization framework of contrast gain control and suggest that contrast normalization accomplishes multiple functional goals.
Masking Release in Children and Adults With Hearing Loss When Using Amplification
McCreery, Ryan; Kopun, Judy; Lewis, Dawna; Alexander, Joshua; Stelmachowicz, Patricia
2016-01-01
Purpose This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method Sentence recognition in unmodulated noise was compared with recognition in modulated noise (masking release). Recognition was measured for participants with hearing loss using individualized amplification via the hearing-aid simulator. Results Adults with hearing loss showed greater masking release than the children with hearing loss. Average masking release was small (1 dB) and did not depend on hearing status. Masking release was comparable for slow and fast compression. Conclusions The use of amplification in this study contrasts with previous studies that did not use amplification. The results suggest that when differences in audibility are reduced, participants with hearing loss may be able to take advantage of dips in the noise levels, similar to participants with normal hearing. Although children required a more favorable signal-to-noise ratio than adults for both unmodulated and modulated noise, masking release was not statistically different. However, the ability to detect a difference may have been limited by the small amount of masking release observed. PMID:26540194
Intact figure-ground segmentation in schizophrenia.
Herzog, Michael H; Kopmann, Sabine; Brand, Andreas
2004-11-30
As revealed by backward masking studies, schizophrenic patients show strong impairments of early visual processing. However, the underlying temporal mechanisms are not yet well understood. To shed light on the exact timing of these deficits, we employed a paradigm in which two masks follow each other. We investigated 16 medicated schizophrenic patients and a matched group of 14 controls with a new backward masking technique, shine-through. In accordance with other masking studies, schizophrenic patients require a dramatically longer processing time to reach a predefined performance level compared with healthy subjects. However, patients are surprisingly sensitive to subtle differences in the timing of the two masks, revealing good temporal resolution. This good temporal resolution indicates intact and fast perceptual grouping and figure-ground segmentation in spite of high susceptibility to masking procedures in schizophrenia.
Unconscious and out of control: subliminal priming is insensitive to observer expectations.
Cressman, Erin K; Lam, Melanie Y; Franks, Ian M; Enns, James T; Chua, Romeo
2013-09-01
We asked whether the influence of an invisible prime on movement is dependent on conscious movement expectations. Participants reached to a central target, which triggered a directional prime-mask arrow sequence. Participants were instructed that the visible arrows (masks) would most often signal a movement modification in a specific (biased) direction. Kinematic analyses revealed that responses to the visible mask were influenced by participants' intentional bias, as movements were fastest when the more probable mask was displayed. In addition, responses were influenced by the invisible prime without regard to its relationship to the more probable mask. Analysis of the time of initial trajectory modifications revealed that both primes influenced responses in a similar manner after accounting for participants' bias. These results imply that invisible stimuli automatically activate their associated responses and that unconscious priming of the motor system is insensitive to the conscious expectations of the participant making the pointing movements. Copyright © 2013 Elsevier Inc. All rights reserved.
Fantini, Marco; Succo, Giovanni; Crosetti, Erika; Borragán Torre, Alfonso; Demo, Roberto; Fussi, Franco
2017-05-01
The current study aimed at investigating the immediate effects of a semi-occluded vocal tract exercise with a ventilation mask in a group of contemporary commercial singers. A randomized controlled study was carried out. Thirty professional or semi-professional singers with no voice complaints were randomly divided into two groups on recruitment: an experimental group and a control group. The same warm-up exercise was performed by the experimental group with an occluded ventilation mask placed over the nose and the mouth and by the control group without the ventilation mask. Voice was recorded before and after the exercise. Acoustic and self-assessment analysis were accomplished. The acoustic parameters of the voice samples recorded before and after training were compared, as well as the parameters' variations between the experimental and the control group. Self-assessment results of the experimental and the control group were compared too. Significant changes after the warm-up exercise included jitter, shimmer, and singing power ratio (SPR) in the experimental group. No significant changes were recorded in the control group. Significant differences between the experimental and the control group were found for ΔShimmer and ΔSPR. Self-assessment analysis confirmed a significantly higher phonatory comfort and voice quality perception for the experimental group. The results of the present study support the immediate advantageous effects on singing voice of a semi-occluded vocal tract exercise with a ventilation mask in terms of acoustic quality, phonatory comfort, and voice quality perception in contemporary commercial singers. Long-term effects still remain to be studied. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gumley, L.; Parker, D.; Flynn, B.; Holz, R.; Marais, W.
2011-12-01
SatCam is an application for iOS devices that allows users to collect observations of local cloud and surface conditions in coordination with an overpass of the Terra, Aqua, or NPP satellites. SatCam allows users to acquire images of sky conditions and ground conditions at their location anywhere in the world using the built-in iPhone or iPod Touch camera at the same time that the satellite is passing overhead and viewing their location. Immediately after the sky and ground observations are acquired, the application asks the user to rate the level of cloudiness in the sky (Completely Clear, Mostly Clear, Partly Cloudy, Overcast). For the ground observation, the user selects their assessment of the surface conditions (Urban, Green Vegetation, Brown Vegetation, Desert, Snow, Water). The sky condition and surface condition selections are stored along with the date, time, and geographic location for the images, and the images are uploaded to a central server. When the MODIS (Terra and Aqua) or VIIRS (NPP) imagery acquired over the user location becomes available, a MODIS or VIIRS true color image centered at the user's location is delivered back to the SatCam application on the user's iOS device. SSEC also proposes to develop a community driven SatCam website where users can share their observations and assessments of satellite cloud products in a collaborative environment. SSEC is developing a server side data analysis system to ingest the SatCam user observations, apply quality control, analyze the sky images for cloud cover, and collocate the observations with MODIS and VIIRS satellite products (e.g., cloud mask). For each observation that is collocated with a satellite observation, the server will determine whether the user scored a "hit", meaning their sky observation and sky assessment matched the automated cloud mask obtained from the satellite observation. The hit rate will be an objective assessment of the accuracy of the user's sky observations. Users with high hit rates will be identified automatically and their observations will be used globally to evaluate the performance of the MODIS cloud mask algorithm for Terra and Aqua and the VIIRS cloud mask algorithm for NPP. The user's assessment of the ground conditions will also be used to evaluate the cloud mask accuracy in selecting the correct surface type at the user's location, which is an important element in the decision path used internally by the cloud mask algorithm. This presentation will describe the SatCam application, how it is used, and show examples of SatCam observations.
Prediction and outcomes of impossible mask ventilation: a review of 50,000 anesthetics.
Kheterpal, Sachin; Martin, Lizabeth; Shanks, Amy M; Tremper, Kevin K
2009-04-01
There are no existing data regarding risk factors for impossible mask ventilation and limited data regarding its incidence. The authors sought to determine the incidence, predictors, and outcomes associated with impossible mask ventilation. The authors performed an observational study over a 4-yr period. For each adult patient undergoing a general anesthetic, preoperative patient characteristics, detailed airway physical exam, and airway outcome data were collected. The primary outcome was impossible mask ventilation defined as the inability to exchange air during bag-mask ventilation attempts, despite multiple providers, airway adjuvants, or neuromuscular blockade. Secondary outcomes included the final, definitive airway management technique and direct laryngoscopy view. The incidence of impossible mask ventilation was calculated. Independent (P < 0.05) predictors of impossible mask ventilation were identified by performing a logistic regression full model fit. Over a 4-yr period from 2004 to 2008, 53,041 attempts at mask ventilation were recorded. A total of 77 cases of impossible mask ventilation (0.15%) were observed. Neck radiation changes, male sex, sleep apnea, Mallampati III or IV, and presence of beard were identified as independent predictors. The receiver-operating-characteristic area under the curve for this model was 0.80 +/- 0.03. Nineteen impossible mask ventilation patients (25%) also demonstrated difficult intubation, with 15 being intubated successfully. Twelve patients required an alternative intubation technique, including two surgical airways and two patients who were awakened and underwent successful fiberoptic intubation. Impossible mask ventilation is an infrequent airway event that is associated with difficult intubation. Neck radiation changes represent the most significant clinical predictor of impossible mask ventilation in the patient dataset.
A face versus non-face context influences amygdala responses to masked fearful eye whites.
Kim, M Justin; Solomon, Kimberly M; Neta, Maital; Davis, F Caroline; Oler, Jonathan A; Mazzulla, Emily C; Whalen, Paul J
2016-12-01
The structure of the mask stimulus is crucial in backward masking studies and we recently demonstrated such an effect when masking faces. Specifically, we showed that activity of the amygdala is increased to fearful facial expressions masked with neutral faces and decreased to fearful expressions masked with a pattern mask-but critically both masked conditions discriminated fearful expressions from happy expressions. Given this finding, we sought to test whether masked fearful eye whites would produce a similar profile of amygdala response in a face vs non-face context. During functional magnetic resonance imaging scanning sessions, 30 participants viewed fearful or happy eye whites masked with either neutral faces or pattern images. Results indicated amygdala activity was increased to fearful vs happy eye whites in the face mask condition, but decreased to fearful vs happy eye whites in the pattern mask condition-effectively replicating and expanding our previous report. Our data support the idea that the amygdala is responsive to fearful eye whites, but that the nature of this activity observed in a backward masking design depends on the mask stimulus. © The Author (2016). Published by Oxford University Press.
LMA Supreme for neonatal resuscitation: study protocol for a randomized controlled trial
2014-01-01
Background The most important action in the resuscitation of a newborn in the delivery room is to establish effective assisted ventilation. The face mask and endotracheal tube are the devices used to achieve this goal. Laryngeal mask airways that fit over the laryngeal inlet have been shown to be effective for ventilating newborns at birth and should be considered as an alternative to facemask ventilation or endotracheal intubation among newborns weighing >2,000 g or delivered ≥34 weeks’ gestation. A recent systematic review and meta-analysis of supraglottic airways in neonatal resuscitation reported the results of four randomized controlled trials (RCTs) stating that fewer infants in the group using laryngeal mask airways required endotracheal intubation (1.5%) compared to the group using face masks (12.0%). However, there were methodological concerns over all the RCTs including the fact that the majority of the operators in the trials were anesthesiologists. Our hypothesis is based on the assumption that ventilating newborns needing positive pressure ventilation with a laryngeal mask airway will be more effective than ventilating with a face mask in a setting where neonatal resuscitation is performed by midwives, nurses, and pediatricians. The primary aim of this study will be to assess the effectiveness of the laryngeal mask airway over the face mask in preventing the need for endotracheal intubation. Methods/design This will be an open, prospective, randomized, single center, clinical trial. In this study, 142 newborns weighing >1,500 g or delivered ≥34 weeks gestation needing positive pressure ventilation at birth will be randomized to be ventilated with a laryngeal mask airway (LMA SupremeTM, LMA Company, UK - intervention group) or with a face mask (control group). Primary outcome: Proportion of newborns needing endotracheal intubation. Secondary outcomes: Apgar score at 5 minutes, time to first breath, onset of the first cry, duration of resuscitation, death or moderate to severe hypoxic-ischemic encephalopathy within 7 days of life. Trial registration ClinicalTrials.gov identifier: NCT01963936 (October 11, 2013). PMID:25027230
Uchida, Mitsuo; Kaneko, Minoru; Hidaka, Yoshihiko; Yamamoto, Hiroshi; Honda, Takayuki; Takeuchi, Shouhei; Saito, Masaya; Kawa, Shigeyuki
2018-03-13
Influenza virus transmission may be prevented by infection control measures, including vaccination, wearing a mask, gargling with water, and hand washing. It is unclear, however, whether these measures affect influenza epidemics in school settings. A prospective epidemiological survey in all public elementary schools in Matsumoto City, Japan, during the 2014/2015 season evaluated the number of diagnosed patients in each school and calculated the reproduction number of schoolchildren. At the end of the prospective survey, a cross-sectional survey evaluated the implementation of infection control measures in these schools. Both results were combined and associations among infection control measures including vaccination, mask wearing, hand washing, water gargling, and epidemic level were evaluated. Of the 13,217 schoolchildren in 29 schools, 2548 were diagnosed with seasonal influenza. A significant negative association was observed between vaccination coverage and reproduction number at each school, but not between other infection control measures and the reproduction number. A regression curve with exponential function was most predictive. At 0% vaccination, the reproduction number was estimated to be 1.39. These findings provide evidence that high vaccination coverage was associated with reduced epidemic levels in schools and suggest the need for increased vaccination of schoolchildren.
Källstrand, Johan; Olsson, Olle; Nehlstedt, Sara Fristedt; Sköld, Mia Ling; Nielzén, Sören
2010-01-01
Abnormal auditory information processing has been reported in individuals with autism spectrum disorders (ASD). In the present study auditory processing was investigated by recording auditory brainstem responses (ABRs) elicited by forward masking in adults diagnosed with Asperger syndrome (AS). Sixteen AS subjects were included in the forward masking experiment and compared to three control groups consisting of healthy individuals (n = 16), schizophrenic patients (n = 16) and attention deficit hyperactivity disorder patients (n = 16), respectively, of matching age and gender. The results showed that the AS subjects exhibited abnormally low activity in the early part of their ABRs that distinctly separated them from the three control groups. Specifically, wave III amplitudes were significantly lower in the AS group than for all the control groups in the forward masking condition (P < 0.005), which was not the case in the baseline condition. Thus, electrophysiological measurements of ABRs to complex sound stimuli (eg, forward masking) may lead to a better understanding of the underlying neurophysiology of AS. Future studies may further point to specific ABR characteristics in AS individuals that separate them from individuals diagnosed with other neurodevelopmental diseases. PMID:20628629
Orthostatic hypertension as a predisposing factor for masked hypertension: the J-SHIPP study.
Tabara, Yasuharu; Igase, Michiya; Miki, Tetsuro; Ohyagi, Yasumasa; Matsuda, Fumihiko; Kohara, Katsuhiko
2016-09-01
Masked hypertension (HT) is a known risk factor for cardiovascular outcomes. Postural blood pressure (BP) dysregulation is another BP phenomenon representing cardiovascular frailty. Given their several shared risk factors, we suspected an inter-relationship between these two BP phenomena. Here we investigated a possible relationship between masked HT and postural BP dysregulation in a general population. Study subjects were 884 apparently healthy individuals (aged 66.3±8.9 years). Masked HT was assessed on the basis of the ambulatory monitored average awake BP and office-measured BP values. Orthostatic BP change was measured at our office after a subject was asked to actively stand up. A strong inverse relationship was noted for orthostatic systolic BP (SBP) change and office-to-awake SBP differences (office-awake BP) (r=-0.422, P<0.001), and these relationships were replicated in the second-visit measurements (n=101, r=-0.326, P=0.001). Multivariate analysis revealed that the inverse association was independent (β=-0.23, P<0.001) of possible covariates, including baseline office BP and antihypertensive treatment. Orthostatic HT (OHT), which is defined as postural increases in SBP >10 mm Hg, 3 min after standing (P=0.001), but not transient HT at only 1 min (P=0.767), was associated with greater office-to-awake SBP differences than in orthostatic normotensive subjects. Among apparently normotensive subjects, the frequency of masked HT was therefore significantly greater in subjects who showed OHT 3 min after standing (52.1%) compared with controls (27.5%) (odds ratio=3.01, P=0.001). We observed an intra-individual relationship between the postural BP change and the office-to-awake BP differences, and subjects who showed OHT were likely to have masked HT irrespective of antihypertensive treatment.
Disposable surgical face masks for preventing surgical wound infection in clean surgery.
Vincent, Marina; Edwards, Peggy
2016-04-26
Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. To determine whether the wearing of disposable surgical face masks by the surgical team during clean surgery reduces postoperative surgical wound infection. In December 2015, for this seventh update, we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials; Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched the bibliographies of all retrieved and relevant publications. There were no restrictions with respect to language, date of publication or study setting. Randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing the use of disposable surgical masks with the use of no mask. Two review authors extracted data independently. We included three trials, involving a total of 2106 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. We identified no new trials for this latest update. From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.
The contribution of forward masking to saccadic inhibition of return.
Souto, David; Born, Sabine; Kerzel, Dirk
2018-03-08
Inhibition of return is the name typically given to the prolonged latency of motor responses directed to a previously cued target location. There is intense debate about the origins of this effect and its function, but most take for granted (despite lack of evidence) that it depends little on forward masking. Therefore, we re-examined the role of forward masking in inhibition of return. Forward masking was indexed by slower saccadic reaction times (SRTs) when the target orientation repeated the cue orientation at the same location. We confirmed effects of orientation repetition in the absence of an attentional bias when cues were presented on both sides of fixation (bilateral presentation). The effect of orientation repetition was reduced with high target contrast, consistent with a low-level origin such as contrast gain control in early visual areas. When presenting cues on only one side of fixation (unilateral presentation), we obtained inhibition of return with longer cue-target intervals and facilitation with targets presented shortly after the cue. The effect of orientation repetition was reduced when facilitation was observed, but was as strong as with bilateral cues when inhibition of return was observed. Therefore, forward masking may contribute to the inhibition of return effect by delaying reaction times to repeated features at the same location, but is not a principal cause of inhibition of return; in agreement with previous views. The saccadic inhibition of return effect is a reaction-time cost when responding to a pre-cued location. Additional object updating costs are typically invoked to explain reaction-time costs observed when cue and target have the same shape. Yet, lower-level, forward masking of the target by the cue can not be ruled out. Importantly, we show an effect of orientation repetition that is consistent with low-level forward masking rather than object updating costs and that does not interact with inhibition of return.
Fielden, Claire A; Kluk, Karolina; McKay, Colette M
2013-06-01
This experiment investigated whether place specificity of neural activity evoked by cochlear implant stimulation is improved in tripolar compared to monopolar mode using a forward masking protocol addressing some limitations of previous methods of measurement and analysis. The amount of residual masking (masking remaining at long masker-probe delays) was also measured, and its potential influence on the specificity measures was evaluated. The masker stimulus comprised equally loud interleaved mono- or tripolar stimulation on two electrodes equidistant from a central probe electrode in an apical and basal direction, reducing the influence of off-site listening. The effect of masker-probe distance on the threshold shift of the tripolar probe was analyzed to derive a measure of place specificity. On average, tripolar maskers were more place specific than monopolar maskers, although the mean effect was small. There was no significant effect of masker level on specificity or on the differences observed between modes. The mean influence of residual masking on normalized masking functions was similar for the two modes and, therefore, did not influence the comparison of specificity between the modes. However, variability in amount of residual masking was observed between subjects, and therefore should be considered in forward masking studies that compare place specificity across subjects.
Development of binary image masks for TPF-C and ground-based AO coronagraphs
NASA Astrophysics Data System (ADS)
Ge, Jian; Crepp, Justin; Vanden Heuvel, Andrew; Miller, Shane; McDavitt, Dan; Kravchenko, Ivan; Kuchner, Marc
2006-06-01
We report progress on the development of precision binary notch-filter focal plane coronagraphic masks for directly imaging Earth-like planets at visible wavelengths with the Terrestrial Planet Finder Coronagraph (TPF-C), and substellar companions at near infrared wavelengths from the ground with coronagraphs coupled to high-order adaptive optics (AO) systems. Our recent theoretical studies show that 8th-order image masks (Kuchner, Crepp & Ge 2005, KCG05) are capable of achieving unlimited dynamic range in an ideal optical system, while simultaneously remaining relatively insensitive to low-spatial-frequency optical aberrations, such as tip/tilt errors, defocus, coma, astigmatism, etc. These features offer a suite of advantages for the TPF-C by relaxing many control and stability requirements, and can also provide resistance to common practical problems associated with ground-based observations; for example, telescope flexure and low-order errors left uncorrected by the AO system due to wavefront sensor-deformable mirror lag time can leak light at significant levels. Our recent lab experiments show that prototype image masks can generate contrast levels on the order of 2x10 -6 at 3 λ/D and 6x10 -7 at 10 λ/D without deformable mirror correction using monochromatic light (Crepp et al. 2006), and that this contrast is limited primarily by light scattered by imperfections in the optics and extra diffraction created by mask construction errors. These experiments also indicate that the tilt and defocus sensitivities of high-order masks follow the theoretical predictions of Shaklan and Green 2005. In this paper, we discuss these topics as well as review our progress on developing techniques for fabricating a new series of image masks that are "free-standing", as such construction designs may alleviate some of the (mostly chromatic) problems associated with masks that rely on glass substrates for mechanical support. Finally, results obtained from our AO coronagraph simulations are provided in the last section. In particular, we find that: (i) apodized masks provide deeper contrast than hard-edge masks when the image quality exceeds 80% Strehl ratio (SR), (ii) above 90% SR, 4th-order band-limited masks provide higher off-axis throughput than Gaussian masks when generating comparable contrast levels, and (iii) below ~90% SR, hard-edge masks may be better suited for high contrast imaging, since they are less susceptible to tip/tilt alignment errors.
Interocular suppression in normal and amblyopic vision: spatio-temporal properties.
Huang, Pi-Chun; Baker, Daniel H; Hess, Robert F
2012-10-31
We measured the properties of interocular suppression in strabismic amblyopes and compared these to dichoptic masking in binocularly normal observers. We used a dichoptic version of the well-established probed-sinewave paradigm that measured sensitivity to a brief target stimulus (one of four letters to be discriminated) in the amblyopic eye at different times relative to a suppression-inducing mask in the fixing eye. This was done using both sinusoidal steady state and transient approaches. The suppression-inducing masks were either modulations of luminance or contrast (full field, just overlaying the target, or just surrounding the target). Our results were interpreted using a descriptive model that included contrast gain control and spatio-temporal filtering prior to excitatory binocular combination. The suppression we measured, other than in magnitude, was not fundamentally different from normal dichoptic masking: lowpass spatio-temporal properties with similar contributions from both surround and overlay suppression.
ERIC Educational Resources Information Center
Werdmann, Anne M.
In a sixth-grade unit, students learned about people's facial expressions through careful observation, recording, reporting, and generalizing. The students studied the faces of people of various ages; explored "masks" that people wear in different situations; learned about the use of ritual masks; made case studies of individuals to show…
Mask aligner for ultrahigh vacuum with capacitive distance control
NASA Astrophysics Data System (ADS)
Bhaskar, Priyamvada; Mathioudakis, Simon; Olschewski, Tim; Muckel, Florian; Bindel, Jan Raphael; Pratzer, Marco; Liebmann, Marcus; Morgenstern, Markus
2018-04-01
We present a mask aligner driven by three piezomotors which guides and aligns a SiN shadow mask under capacitive control towards a sample surface. The three capacitors for read out are located at the backside of the thin mask such that the mask can be placed at a μm distance from the sample surface, while keeping it parallel to the surface, without touching the sample by the mask a priori. Samples and masks can be exchanged in-situ and the mask can additionally be displaced parallel to the surface. We demonstrate an edge sharpness of the deposited structures below 100 nm, which is likely limited by the diffusion of the deposited Au on Si(111).
Lenslet Array to Further Suppress Star Light for Direct Exoplanet Detection
NASA Technical Reports Server (NTRS)
Gong, Qian; McElwain, Michael; Shiri, Ron
2016-01-01
Direct imaging plays a key role in the detection and characterization of exoplanets orbiting within its host star's habitable zone. Many innovative ideas for starlight suppression and wavefront control have been proposed and developed over the past decade. However, several technological challenges still lie ahead to achieve the required contrast, including controlling the observatory pointing performance, fabricating occulting masks with tight optical tolerances, developing wavefront control algorithms, controlling stray light, advancing single photon detecting detectors, and integrated system-level issues. This paper explores how a lenslet array and pinhole mask may be implemented to further suppress uncorrected starlight that leaks through the occulting mask. An external occulter, or star shade, is simulated to demonstrate this concept, although this approach can be implemented for internal coronagraphs as well. We describe how to use simple relay optics to control the scene near the inner working angle and the level of the suppression expected. Furthermore, if the lenslet array is the input to an integral field spectrograph, as planned for the WFIRST mission, the spectral content of the exoplanet atmospheres can be obtained to determine if the observed planet is habitable and ultimately, if it is inhabited.
The technical consideration of multi-beam mask writer for production
NASA Astrophysics Data System (ADS)
Lee, Sang Hee; Ahn, Byung-Sup; Choi, Jin; Shin, In Kyun; Tamamushi, Shuichi; Jeon, Chan-Uk
2016-10-01
Multi-beam mask writer is under development to solve the throughput and patterning resolution problems in VSB mask writer. Theoretically, the writing time is appropriate for future design node and the resolution is improved with multi-beam mask writer. Many previous studies show the feasible results of resolution, CD control and registration. Although such technical results of development tool seem to be enough for mass production, there are still many unexpected problems for real mass production. In this report, the technical challenges of multi-beam mask writer are discussed in terms of production and application. The problems and issues are defined based on the performance of current development tool compared with the requirements of mask quality. Using the simulation and experiment, we analyze the specific characteristics of electron beam in multi-beam mask writer scheme. Consequently, we suggest necessary specifications for mass production with multi-beam mask writer in the future.
Resist heating effect on e-beam mask writing at 75 kV and 60 A/cm2
NASA Astrophysics Data System (ADS)
Benes, Zdenek; Deverich, Christina; Huang, Chester; Lawliss, Mark
2003-12-01
Resist heating has been known to be one of the main contributors to local CD variation in mask patterning using variable shape e-beam tools. Increasingly complex mask patterns require increased number of shapes which drives the need for higher electron beam current densities to maintain reasonable write times. As beam current density is increased, CD error resulting from resist heating may become a dominating contributor to local CD variations. In this experimental study, the IBM EL4+ mask writer with high voltage and high current density has been used to quantitatively investigate the effect of resist heating on the local CD uniformity. ZEP 7000 and several chemically amplified resists have been evaluated under various exposure conditions (single-pass, multi-pass, variable spot size) and pattern densities. Patterns were designed specifically to allow easy measurement of local CD variations with write strategies designed to maximize the effect of resist heating. Local CD variations as high as 15 nm in 18.75 × 18.75 μm sub-field size have been observed for ZEP 7000 in a single-pass writing with full 1000 nm spots at 50% pattern density. This number can be reduced by increasing the number of passes or by decreasing the maximum spot size. The local CD variation has been reduced to as low as 2 nm for ZEP 7000 for the same pattern under modified exposure conditions. The effectiveness of various writing strategies is discussed as well as their possible deficiencies. Minimal or no resist heating effects have been observed for the chemically amplified resists studied. The results suggest that the resist heating effect can be well controlled by careful selection of the resist/process system and/or writing strategy and that resist heating does not have to pose a problem for high throughput e-beam mask making that requires high voltage and high current densities.
Self-masking: Listening during vocalization. Normal hearing.
Borg, Erik; Bergkvist, Christina; Gustafsson, Dan
2009-06-01
What underlying mechanisms are involved in the ability to talk and listen simultaneously and what role does self-masking play under conditions of hearing impairment? The purpose of the present series of studies is to describe a technique for assessment of masked thresholds during vocalization, to describe normative data for males and females, and to focus on hearing impairment. The masking effect of vocalized [a:] on narrow-band noise pulses (250-8000 Hz) was studied using the maximum vocalization method. An amplitude-modulated series of sound pulses, which sounded like a steam engine, was masked until the criterion of halving the perceived pulse rate was reached. For masking of continuous reading, a just-follow-conversation criterion was applied. Intra-session test-retest reproducibility and inter-session variability were calculated. The results showed that female voices were more efficient in masking high frequency noise bursts than male voices and more efficient in masking both a male and a female test reading. The male had to vocalize 4 dBA louder than the female to produce the same masking effect on the test reading. It is concluded that the method is relatively simple to apply and has small intra-session and fair inter-session variability. Interesting gender differences were observed.
Excitation-based and informational masking of a tonal signal in a four-tone masker.
Leibold, Lori J; Hitchens, Jack J; Buss, Emily; Neff, Donna L
2010-04-01
This study examined contributions of peripheral excitation and informational masking to the variability in masking effectiveness observed across samples of multi-tonal maskers. Detection thresholds were measured for a 1000-Hz signal presented simultaneously with each of 25, four-tone masker samples. Using a two-interval, forced-choice adaptive task, thresholds were measured with each sample fixed throughout trial blocks for ten listeners. Average thresholds differed by as much as 26 dB across samples. An excitation-based model of partial loudness [Moore, B. C. J. et al. (1997). J. Audio Eng. Soc. 45, 224-237] was used to predict thresholds. These predictions accounted for a significant portion of variance in the data of several listeners, but no relation between the model and data was observed for many listeners. Moreover, substantial individual differences, on the order of 41 dB, were observed for some maskers. The largest individual differences were found for maskers predicted to produce minimal excitation-based masking. In subsequent conditions, one of five maskers was randomly presented in each interval. The difference in performance for samples with low versus high predicted thresholds was reduced in random compared to fixed conditions. These findings are consistent with a trading relation whereby informational masking is largest for conditions in which excitation-based masking is smallest.
Naser, Nabil; Dzubur, Alen; Durak, Azra; Kulic, Mehmed; Naser, Nura
2016-07-27
The term masked hypertension (MH) should be used for untreated individuals who have normal office blood pressure but elevated ambulatory blood pressure. For treated patients, this condition should be termed masked uncontrolled hypertension (MUCH). Masked uncontrolled hypertension (MUCH) has gone unrecognized because few studies have used 24-h ABPM to determine the prevalence of suboptimal BP control in seemingly well-treated patients, and there are few such studies in large cohorts of treated patients attending usual clinical practice. This is important because masked hypertension is associated with a high risk of cardiovascular events. This study was conducted to obtain more information about the association between hypertension and other CV risk factors, about office and ambulatory blood pressure (BP) control as well as on cardiovascular (CV) risk profile in treated hypertensive patients, also to define the prevalence and characteristics of masked uncontrolled hypertension (MUCH) among treated hypertensive patients in routine clinical practice. In this study 2514 male and female patients were included during a period of 5 years follow up. All patients have ambulatory blood pressure monitoring (ABPM) for at least 24h. We identified patients with treated and controlled BP according to current international guidelines (clinic BP, 140/90mmHg). Cardiovascular risk assessment was based on personal history, clinic BP values, as well as target organ damage evaluation. Masked uncontrolled hypertension (MUCH) was diagnosed in these patients if despite controlled clinic BP, the mean 24-h ABPM average remained elevated (24-h systolic BP ≥130mmHg and/or 24-h diastolic BP ≥80mmHg). Patients had a mean age of 60.2+10 years, and the majority of them (94.6%) were followed by specialist physicians. Average clinic BP was 150.4+16/89.9+12 mmHg. About 70% of patients displayed a very high-risk profile. Ambulatory blood pressure monitoring (ABPM) was performed in all recruited patients for at least 24h. Despite the combined medical treatment (78% of the patients), clinic control (<140/90 mmHg) was achieved in only 26.2% of patients, the corresponding control rate for ambulatory BP (<130/80 mmHg) being 32.7%. From 2514 patients with treated BP, we identified 803 with treated and controlled office BP control (<140/90 mmHg), of whom 258 patients (32.1%) had MUCH according to 24-h ABPM criteria (mean age 57.2 years, 54.7% men). The prevalence of MUCH was slightly higher in males, patients with borderline clinic and office BP (130-139/80-89 mmHg), and patients at high cardiovascular risk (smokers, diabetes, obesity). Masked uncontrolled hypertension (MUCH) was most often due to poor control of nocturnal BP, with the proportion of patients in whom MUCH was solely attributable to an elevated nocturnal BP almost double that solely attributable to daytime BP elevation (22.3 vs. 10.1%, P 0.001). The prevalence of masked suboptimal BP control in patients with treated and well-controlled clinic BP is high. The characteristics of patients with MUCH (male, longer duration of hypertension, obesity, smoking history, and diabetes) indicate that this is a higher-risk group with most to gain from improved BP.
Baker, Daniel H; Meese, Tim S; Hess, Robert F
2008-07-01
To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrast discrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224-1243.] was 'lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.
Force-dependent static dead space of face masks used with holding chambers.
Shah, Samir A; Berlinski, Ariel B; Rubin, Bruce K
2006-02-01
Pressurized metered-dose inhalers with valved holding chambers and masks are commonly used for aerosol delivery in children. Drug delivery can decrease when the dead-space volume (DSV) of the valved holding chamber is increased, but there are no published data evaluating force-dependent DSV among different masks. Seven masks were studied. Masks were sealed at the valved holding chamber end and filled with water to measure mask volume. To measure mask DSV we used a mannequin of 2-year-old-size face and we applied the mask with forces of 1.5, 3.5, and 7 pounds. Mask seal was determined by direct observation. Intra-brand analysis was done via analysis of variance. At 3.5 pounds of force, the DSV ranged from 29 mL to 100 mL, with 3 masks having DSV of < 50 mL. The remaining masks all had DSV > 60 mL. At 3.5 pounds of force, DSV percent of mask volume ranged from 33.7% (Aerochamber, p < 0.01 compared with other masks) to 100% (Pocket Chamber). DSV decreased with increasing force with most of the masks, and the slope of this line was inversely proportional to mask flexibility. Mask fit was 100% at 1.5 pounds of force only with the Aerochamber and Optichamber. Mask fit was poorest with the Vortex, Pocket Chamber, and BreatheRite masks. Rigid masks with large DSV might not be not suitable for use in children, especially if discomfort from the stiff mask makes its use less acceptable to the child.
NASA Astrophysics Data System (ADS)
MacMahon, Heber; Vyborny, Carl; Sabeti, Victoria; Metz, Charles; Doi, Kunio
1985-09-01
A potential advantage of digital radiographic systems is their ability to enhance images by various types of processing. Digital unsharp masking is one of the simplest and potentially most useful forms of enhancement. The efficacy of unsharp masking in clinical radiologic diagnosis has not been investigated systematically, however. The effect of digital unsharp masking on the detectability of two types of subtle abnormalities, pneumothorax and interstitial infiltrate, was studied in an observer performance test. An ROC analysis of this preliminary data suggests that unsharp masking may improve diagnostic accuracy for pneumothorax. Radiologists' performance in identifying interstitial infiltrates was degraded by the image processing, however, and false positive diagnoses tended to be more frequent.
Sivaprasad, Sobha; Vasconcelos, Joana C; Prevost, A Toby; Holmes, Helen; Hykin, Philip; George, Sheena; Murphy, Caroline; Kelly, Joanna; Arden, Geoffrey B
2018-05-01
We aimed to assess 24-month outcomes of wearing an organic light-emitting sleep mask as an intervention to treat and prevent progression of non-central diabetic macular oedema. CLEOPATRA was a phase 3, single-blind, parallel-group, randomised controlled trial undertaken at 15 ophthalmic centres in the UK. Adults with non-centre-involving diabetic macular oedema were randomly assigned (1:1) to wearing either a light mask during sleep (Noctura 400 Sleep Mask, PolyPhotonix Medical, Sedgefield, UK) or a sham (non-light) mask, for 24 months. Randomisation was by minimisation generated by a central web-based computer system. Outcome assessors were masked technicians and optometrists. The primary outcome was the change in maximum retinal thickness on optical coherence tomography (OCT) at 24 months, analysed using a linear mixed-effects model incorporating 4-monthly measurements and baseline adjustment. Analysis was done using the intention-to-treat principle in all randomised patients with OCT data. Safety was assessed in all patients. This trial is registered with Controlled-Trials.com, number ISRCTN85596558. Between April 10, 2014, and June 15, 2015, 308 patients were randomly assigned to wearing the light mask (n=155) or a sham mask (n=153). 277 patients (144 assigned the light mask and 133 the sham mask) contributed to the mixed-effects model over time, including 246 patients with OCT data at 24 months. The change in maximum retinal thickness at 24 months did not differ between treatment groups (mean change -9·2 μm [SE 2·5] for the light mask vs -12·9 μm [SE 2·9] for the sham mask; adjusted mean difference -0·65 μm, 95% CI -6·90 to 5·59; p=0·84). Median compliance with wearing the light mask at 24 months was 19·5% (IQR 1·9-51·6). No serious adverse events were related to either mask. The most frequent adverse events related to the assigned treatment were discomfort on the eyes (14 with the light mask vs seven with the sham mask), painful, sticky, or watery eyes (14 vs six), and sleep disturbance (seven vs one). The light mask as used in this study did not confer long-term therapeutic benefit on non-centre-involving diabetic macular oedema and the study does not support its use for this indication. The Efficacy and Mechanism Evaluation Programme, a Medical Research Council and National Institute for Health Research partnership. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.
Feedforward and feedback control in apraxia of speech: effects of noise masking on vowel production.
Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H
2015-04-01
This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed.
Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production
Mailend, Marja-Liisa; Guenther, Frank H.
2015-01-01
Purpose This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Results Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. Conclusion The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed. PMID:25565143
Forward masking of frequency modulationa
Byrne, Andrew J.; Wojtczak, Magdalena; Viemeister, Neal F.
2012-01-01
Forward masking of sinusoidal frequency modulation (FM) was measured with three types of maskers: FM, amplitude modulation (AM), and a masker created by combining the magnitude spectrum of an FM tone with random component phases. For the signal FM rates used (5, 20, and 40 Hz), an FM masker raised detection thresholds in terms of frequency deviation by a factor of about 5 relative to without a masker. The AM masker produced a much smaller effect, suggesting that FM-to-AM conversion did not contribute substantially to the FM forward masking. The modulation depth of an FM masker had a nonmonotonic effect, with maximal masking observed at an intermediate value within the range of possible depths, while the random-phase FM masker produced less masking, arguing against a spectrally-based explanation for FM forward masking. Broad FM-rate selectivity for forward masking was observed for both 4-kHz and 500-Hz carriers. Thresholds measured as a function of the masker-signal delay showed slow recovery from FM forward masking, with residual masking for delays up to 500 ms. The FM forward-masking effect resembles that observed for AM [Wojtczak and Viemeister (2005). J. Acoust. Soc. Am. 188, 3198–3210] and may reflect modulation-rate selective neural adaptation to FM. PMID:23145618
Increased dead space in face mask continuous positive airway pressure in neonates.
Hishikawa, Kenji; Fujinaga, Hideshi; Ito, Yushi
2017-01-01
Continuous positive airway pressure (CPAP) by face mask is commonly performed in newborn resuscitation. We evaluated the effect of face mask CPAP on system dead space. Face mask CPAP increases dead space. A CPAP model study. We estimated the volume of the inner space of the mask. We devised a face mask CPAP model, in which the outlet of the mask was covered with plastic; and three modified face mask CPAP models, in which holes were drilled near to the cushion of the covered face mask to alter the air exit. We passed a continuous flow of 21% oxygen through each model and we controlled the inner pressure to 5 cmH 2 O by adjusting the flow-relief valve. To evaluate the ventilation in the inner space of each model, we measured the oxygen concentration rise time, that is, the time needed for the oxygen concentration of each model to reach 35% after the oxygen concentration of the continuous flow was raised from 21% to 40%. The volume of inner space of the face mask was 38.3 ml. Oxygen concentration rise time in the face mask CPAP model was significantly longer at various continuous flow rates and points of the inner space of the face mask compared with that of the modified face mask CPAP model. Our study indicates that face mask CPAP leads to an increase in dead space and a decrease in ventilation efficiency under certain circumstances. Pediatr Pulmonol. 2017;52:107-111. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Emotional conditioning to masked stimuli and modulation of visuospatial attention.
Beaver, John D; Mogg, Karin; Bradley, Brendan P
2005-03-01
Two studies investigated the effects of conditioning to masked stimuli on visuospatial attention. During the conditioning phase, masked snakes and spiders were paired with a burst of white noise, or paired with an innocuous tone, in the conditioned stimulus (CS)+ and CS- conditions, respectively. Attentional allocation to the CSs was then assessed with a visual probe task, in which the CSs were presented unmasked (Experiment 1) or both unmasked and masked (Experiment 2), together with fear-irrelevant control stimuli (flowers and mushrooms). In Experiment 1, participants preferentially allocated attention to CS+ relative to control stimuli. Experiment 2 suggested that this attentional bias depended on the perceived aversiveness of the unconditioned stimulus and did not require conscious recognition of the CSs during both acquisition and expression. Copyright 2005 APA, all rights reserved.
Marine Mammals: Hearing and Echolocation at Coconut Island
2009-09-30
113(5), 2408-2411 5 Supin, A. Ya., Nachtigall, P.E., and Breese, M. (2009) Forward masking based gain control in odontocete biosonar : an evoked...odontocete biosonar : an evoked-potential study. J Acous Soc Am (published, refereed) Mooney T.A., Nachtigall, P.E. Breese, M. Vlachos, S. and...Nachtigall, P.E. and Breese, M. (2008) Forward masking as a mechanism of automatic gain control in whale biosonar : a psychophysical study, Journal of the
NASA Astrophysics Data System (ADS)
Zait, Eitan; Ben-Zvi, Guy; Dmitriev, Vladimir; Oshemkov, Sergey; Pforr, Rainer; Hennig, Mario
2006-05-01
Intra-field CD variation is, besides OPC errors, a main contributor to the total CD variation budget in IC manufacturing. It is caused mainly by mask CD errors. In advanced memory device manufacturing the minimum features are close to the resolution limit resulting in large mask error enhancement factors hence large intra-field CD variations. Consequently tight CD Control (CDC) of the mask features is required, which results in increasing significantly the cost of mask and hence the litho process costs. Alternatively there is a search for such techniques (1) which will allow improving the intrafield CD control for a given moderate mask and scanner imaging performance. Currently a new technique (2) has been proposed which is based on correcting the printed CD by applying shading elements generated in the substrate bulk of the mask by ultrashort pulsed laser exposure. The blank transmittance across a feature is controlled by changing the density of light scattering pixels. The technique has been demonstrated to be very successful in correcting intra-field CD variations caused by the mask and the projection system (2). A key application criterion of this technique in device manufacturing is the stability of the absorbing pixels against DUV light irradiation being applied during mask projection in scanners. This paper describes the procedures and results of such an investigation. To do it with acceptable effort a special experimental setup has been chosen allowing an evaluation within reasonable time. A 193nm excimer laser with pulse duration of 25 ns has been used for blank irradiation. Accumulated dose equivalent to 100,000 300 mm wafer exposures has been applied to Half Tone PSM mask areas with and without CDC shadowing elements. This allows the discrimination of effects appearing in treated and untreated glass regions. Several intensities have been investigated to define an acceptable threshold intensity to avoid glass compaction or generation of color centers in the glass. The impact of the irradiation on the mask transmittance of both areas has been studied by measurements of the printed CD on wafer using a wafer scanner before and after DUV irradiation.
Optimizing defect inspection strategy through the use of design-aware database control layers
NASA Astrophysics Data System (ADS)
Stoler, Dvori; Ruch, Wayne; Ma, Weimin; Chakravarty, Swapnajit; Liu, Steven; Morgan, Ray; Valadez, John; Moore, Bill; Burns, John
2007-10-01
Resolution limitations in the mask making process can cause differences between the features that appear in a database and those printed to a reticle. These differences may result from intentional or unintentional features in the database exceeding the resolution limit of the mask making process such as small gaps or lines in the data, line end shortening on small sub-resolution assist features etc creating challenges to both mask writing and mask inspection. Areas with high variance from design to mask, often referred to as high MEEF areas (mask error enhancement factor), become highly problematic and can directly impact mask and device yield, mask manufacturing cycle time and ultimately mask costs. Specific to mask inspection it may be desirable to inspect certain non-critical or non-relevant features at reduced sensitivity so as not to detect real, but less significant process defects. In contrast there may also be times where increased sensitivity is required for critical mask features or areas. Until recently, this process was extremely manual, creating added time and cost to the mask inspection cycle. Shifting to more intelligent and automated inspection flows is the key focus of this paper. A novel approach to importing design data directly into the mask inspection to include both MDP generated MRC errors files and LRC generated MEEF files. The results of recently developed inspection and review capability based upon controlling defect inspection using design aware data base control layers on a pixel basis are discussed. Typical mask shop applications and implementations will be shown.
Häberle, Lothar; Hack, Carolin C; Heusinger, Katharina; Wagner, Florian; Jud, Sebastian M; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger; Wittenberg, Thomas; Fasching, Peter A
2017-08-30
Tumors in radiologically dense breast were overlooked on mammograms more often than tumors in low-density breasts. A fast reproducible and automated method of assessing percentage mammographic density (PMD) would be desirable to support decisions whether ultrasonography should be provided for women in addition to mammography in diagnostic mammography units. PMD assessment has still not been included in clinical routine work, as there are issues of interobserver variability and the procedure is quite time consuming. This study investigated whether fully automatically generated texture features of mammograms can replace time-consuming semi-automatic PMD assessment to predict a patient's risk of having an invasive breast tumor that is visible on ultrasound but masked on mammography (mammography failure). This observational study included 1334 women with invasive breast cancer treated at a hospital-based diagnostic mammography unit. Ultrasound was available for the entire cohort as part of routine diagnosis. Computer-based threshold PMD assessments ("observed PMD") were carried out and 363 texture features were obtained from each mammogram. Several variable selection and regression techniques (univariate selection, lasso, boosting, random forest) were applied to predict PMD from the texture features. The predicted PMD values were each used as new predictor for masking in logistic regression models together with clinical predictors. These four logistic regression models with predicted PMD were compared among themselves and with a logistic regression model with observed PMD. The most accurate masking prediction was determined by cross-validation. About 120 of the 363 texture features were selected for predicting PMD. Density predictions with boosting were the best substitute for observed PMD to predict masking. Overall, the corresponding logistic regression model performed better (cross-validated AUC, 0.747) than one without mammographic density (0.734), but less well than the one with the observed PMD (0.753). However, in patients with an assigned mammography failure risk >10%, covering about half of all masked tumors, the boosting-based model performed at least as accurately as the original PMD model. Automatically generated texture features can replace semi-automatically determined PMD in a prediction model for mammography failure, such that more than 50% of masked tumors could be discovered.
Advanced refractory-metal and process technology for the fabrication of x-ray masks
NASA Astrophysics Data System (ADS)
Brooks, Cameron J.; Racette, Kenneth C.; Lercel, Michael J.; Powers, Lynn A.; Benoit, Douglas E.
1999-06-01
This paper provides an in-depth report of the advanced materials and process technology being developed for x-ray mask manufacturing at IBM. Masks using diamond membranes as replacement for silicon carbide are currently being fabricated. Alternate tantalum-based absorbers, such as tantalum boron, which offer improved etch resolution and critical dimension control, as well as higher x-ray absorption, are also being investigated. In addition to the absorber studies, the development of conductive chromium- based hard-mask films to replace the current silicon oxynitride layer is being explored. The progress of this advanced-materials work, which includes significant enhancements to x-ray mask image-placement performance, will be outlined.
NASA Astrophysics Data System (ADS)
Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho
2013-04-01
As the International Technology Roadmap for Semiconductors critical dimension uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. We will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for advanced extreme ultraviolet (EUV) lithography with 1D (dense lines) and 2D (dense contacts) feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CDs and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples. Mask stack reflectivity variations should also be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We also observed mask error enhancement factor (MEEF) through field fingerprints in the studied EUV cases. Variations of MEEF may play a role towards the total intrafield CDU and may need to be taken into account for EUV lithography. We characterized MEEF-through-field for the reviewed features, with results herein, but further analysis of this phenomenon is required. This comprehensive approach to quantifying the mask part of the overall EUV CDU contribution helps deliver an accurate and integral CDU BB per product/process and litho tool. The better understanding of the entire CDU budget for advanced EUVL nodes achieved by Samsung and ASML helps extend the limits of Moore's Law and to deliver successful implementation of smaller, faster and smarter chips in semiconductor industry.
Hemmesch, Amanda R; Tickle-Degnen, Linda; Zebrowitz, Leslie A
2009-09-01
Parkinson's disease (PD) involves facial masking, which may impair social interaction. Older adult observers who viewed segments of videotaped interviews of individuals with PD expressed less interest in relationships with women with higher masking and judged them as less supportive. Masking did not affect ratings of men in these domains, possibly because higher masking violates gender norms for expressivity in women but not in men. Observers formed less accurate ratings of the social supportiveness and social strain of women than men, and higher masking decreased accuracy for ratings of strain. Results suggest that some of the problems with social relationships in PD may be due to inaccurate impressions and reduced desire to interact with individuals with higher masking, especially women. (c) 2009 APA, all rights reserved.
In-line verification of linewidth uniformity for 0.18 and below: design rule reticles
NASA Astrophysics Data System (ADS)
Tan, TaiSheng; Kuo, Shen C.; Wu, Clare; Falah, Reuven; Hemar, Shirley; Sade, Amikam; Gottlib, Gidon
2000-07-01
Mask making process development and control is addressed using a reticle inspection tool equipped with the new revolutionized application called LBM-Linewidth Bias Monitoring. In order to use the LBM for mask-making process control, procedures and corresponding test plates are a developed, such that routine monitoring of the manufacturing process discloses process variation and machine variation. At the same time systematic variation are studied and either taken care of or taken into consideration to allow successful production line work. In this paper the contribution of the LBM for mask quality monitoring is studied with respect to dense layers, e.g. DRAM. Another aspect of this application - the detection of very small CD mis-uniformity areas is discussed.
Hasenäcker, Jana; Beyersmann, Elisabeth; Schroeder, Sascha
2016-01-01
In this study, we looked at masked morphological priming effects in German children and adults beyond mean response times by taking into account response time distributions. We conducted an experiment comparing suffixed word primes (kleidchen-KLEID), suffixed nonword primes (kleidtum-KLEID), nonsuffixed nonword primes (kleidekt-KLEID), and unrelated controls (träumerei-KLEID). The pattern of priming in adults showed facilitation from suffixed words, suffixed nonwords, and nonsuffixed nonwords relative to unrelated controls, and from both suffixed conditions relative to nonsuffixed nonwords, thus providing evidence for morpho-orthographic and embedded stem priming. Children also showed facilitation from real suffixed words, suffixed nonwords, and nonsuffixed nonwords compared to unrelated words, but no difference between the suffixed and nonsuffixed conditions, thus suggesting that German elementary school children do not make use of morpho-orthographic segmentation. Interestingly, for all priming effects, a shift of the response time distribution was observed. Consequences for theories of morphological processing are discussed. PMID:27445899
Increased masked hypertension prevalence in patients with obesity.
Özkan, Selçuk; Ata, Naim; Yavuz, Bunyamin
2018-02-08
Masked hypertension is associated with an increased risk for cardiovascular conditions. The aim of the study was to evaluate the relationship obesity parameters, including body weight, waist circumference, and body mass index. The study group consisted of 251 consecutive outpatient subjects without overt hypertension. Subjects were classified according to BMI. After a complete medical history and laboratory examination, patients' height, weight, waist circumference heart rate, and office blood pressure were recorded. All subjects underwent ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of Masked hypertension was significantly higher in patients with obesity than controls (30.9% vs 5.7%, p < 0.001). Body mass index (33.2 ± 4.3 vs 25.1 ± 2.7 p < 0.001), waist circumference (98.5 ± 11.7 vs 86.8 ± 8.8, p < 0.001), and weight (86.5 ± 11.8 vs. 69 ± 9.1, p < 0.001) in patients with obesity were significantly higher than in patients with normal weight. Office Systolic BP (121.8 ± 4.4 vs 120.5 ± 4.78, p = 0.035), ambulatory daytime systolic BP (128.8 ± 8.9 vs 124.5 ± 7.4, p < 0.001), ambulatory daytime diastolic BP (73.9 ± 9.5 vs 71.5 ± 7.0, p = 0.019), ambulatory night-time systolic BP in patients with obesity was significantly higher than in patients with normal weight. This study demonstrated that masked hypertension prevalence is higher in patients with obesity than control patients. It can be suggested that predefining obesity might be helpful in early detection of masked hypertension.
Competing for Consciousness: Prolonged Mask Exposure Reduces Object Substitution Masking
ERIC Educational Resources Information Center
Goodhew, Stephanie C.; Visser, Troy A. W.; Lipp, Ottmar V.; Dux, Paul E.
2011-01-01
In object substitution masking (OSM) a sparse, temporally trailing 4-dot mask impairs target identification, even though it has different contours from, and does not spatially overlap with the target. Here, we demonstrate a previously unknown characteristic of OSM: Observers show reduced masking at prolonged (e.g., 640 ms) relative to intermediate…
Shamsi, Mahmoud; Pariani, Abbas; Shams, Mohsen; Soleymani-nejad, Marzieh
2016-04-01
To study the effects of an intervention based on social marketing to persuade workers to use personal protective equipment (PPE) in constructing subway stations in Isfahan, Iran. This was a quasi-experimental study. Two stations were selected as intervention and control groups. Intervention was designed based on results of a formative research. A free package containing a safety helmet with a tailored message affixed to it, mask and gloves and an educational pamphlet was delivered to the intervention group. After 6 weeks, behaviours in the intervention and control stations were measured using an observational checklist. After the intervention, the percentage of workers who used PPE at the intervention station increased significantly. OR for helmet and mask usage was 7.009 and 2.235, respectively, in the intervention group. Social marketing can be used to persuade workers to use PPE in the workplace. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Adaptation to different noninvasive ventilation masks in critically ill patients*
da Silva, Renata Matos; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta
2013-01-01
OBJECTIVE: To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. METHODS: An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. RESULTS: We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. CONCLUSIONS: In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed. PMID:24068269
Adaptation to different noninvasive ventilation masks in critically ill patients.
Silva, Renata Matos da; Timenetsky, Karina Tavares; Neves, Renata Cristina Miranda; Shigemichi, Liane Hirano; Kanda, Sandra Sayuri; Maekawa, Carla; Silva, Eliezer; Eid, Raquel Afonso Caserta
2013-01-01
To identify which noninvasive ventilation (NIV) masks are most commonly used and the problems related to the adaptation to such masks in critically ill patients admitted to a hospital in the city of São Paulo, Brazil. An observational study involving patients ≥ 18 years of age admitted to intensive care units and submitted to NIV. The reason for NIV use, type of mask, NIV regimen, adaptation to the mask, and reasons for non-adaptation to the mask were investigated. We evaluated 245 patients, with a median age of 82 years. Acute respiratory failure was the most common reason for NIV use (in 71.3%). Total face masks were the most commonly used (in 74.7%), followed by full face masks and near-total face masks (in 24.5% and 0.8%, respectively). Intermittent NIV was used in 82.4% of the patients. Adequate adaptation to the mask was found in 76% of the patients. Masks had to be replaced by another type of mask in 24% of the patients. Adequate adaptation to total face masks and full face masks was found in 75.5% and 80.0% of the patients, respectively. Non-adaptation occurred in the 2 patients using near-total facial masks. The most common reason for non-adaptation was the shape of the face, in 30.5% of the patients. In our sample, acute respiratory failure was the most common reason for NIV use, and total face masks were the most commonly used. The most common reason for non-adaptation to the mask was the shape of the face, which was resolved by changing the type of mask employed.
More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies.
Amirav, Israel; Halamish, Asaf; Gorenberg, Miguel; Omar, Hamza; Newhouse, Michael T
2015-01-01
Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic "face" surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. To compare mask to "face" seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the "face." Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. The soft "face" significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft "face" was significantly greater for the SM compared to the AC (p< 0.01). No statistically significant difference between the two masks was observed with the hard "face." The material and pliability of the model "face" surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies.
Filter penetration and breathing resistance evaluation of respirators and dust masks.
Ramirez, Joel; O'Shaughnessy, Patrick
2017-02-01
The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p < 0.001). The breathing resistances of the unused FFRs and dust masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p < 0.001). After dust loading there was a significant difference between the BR caused by the ARD dust layer on each FFR and dust mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values < 5% and quality factors (0.26 and 0.33) comparable to those obtained for the two FFRs (0.23 and 0.31). However, the remaining three dust masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.
When things go pear shaped: contour variations of contacts
NASA Astrophysics Data System (ADS)
Utzny, Clemens
2013-04-01
Traditional control of critical dimensions (CD) on photolithographic masks considers the CD average and a measure for the CD variation such as the CD range or the standard deviation. Also systematic CD deviations from the mean such as CD signatures are subject to the control. These measures are valid for mask quality verification as long as patterns across a mask exhibit only size variations and no shape variation. The issue of shape variations becomes especially important in the context of contact holes on EUV masks. For EUV masks the CD error budget is much smaller than for standard optical masks. This means that small deviations from the contact shape can impact EUV waver prints in the sense that contact shape deformations induce asymmetric bridging phenomena. In this paper we present a detailed study of contact shape variations based on regular product data. Two data sets are analyzed: 1) contacts of varying target size and 2) a regularly spaced field of contacts. Here, the methods of statistical shape analysis are used to analyze CD SEM generated contour data. We demonstrate that contacts on photolithographic masks do not only show size variations but exhibit also pronounced nontrivial shape variations. In our data sets we find pronounced shape variations which can be interpreted as asymmetrical shape squeezing and contact rounding. Thus we demonstrate the limitations of classic CD measures for describing the feature variations on masks. Furthermore we show how the methods of statistical shape analysis can be used for quantifying the contour variations thus paving the way to a new understanding of mask linearity and its specification.
Nasal mask ventilation is better than face mask ventilation in edentulous patients.
Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil
2016-01-01
Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients.
NASA Astrophysics Data System (ADS)
Gordon, Michael; Seiler, Theo; Carey, Joseph P.; Friedman, Marc D.; Johnsson, N. M. F.; King, Michael C.; Muller, David F.
1993-06-01
This paper reports on our progress using an erodible mask to perform photorefractive keratectomy (PRK) for the correction of myopic astigmatism. We describe modifications to the mask, the mask eye cup and the surgical microscope aimed at simplifying the procedure and improving the ergonomics of the hardware. We report the clinical results of the post-op exam for 20 patients who have undergone PRK for myopic astigmatism under a Phase IIA study. The results compare favorably with an earlier Phase IIA study for performing PRK with a computer-controlled iris. Most important, the clinical data show the absence of any significant corneal haze and no significant decrease in spectacle corrected visual acuity. Although more long term follow-up is needed, the preliminary results support the safety and effectiveness of using an erodible mask to perform PRK for myopic astigmatism.
Overlay degradation induced by film stress
NASA Astrophysics Data System (ADS)
Huang, Chi-hao; Liu, Yu-Lin; Luo, Shing-Ann; Yang, Mars; Yang, Elvis; Hung, Yung-Tai; Luoh, Tuung; Yang, T. H.; Chen, K. C.
2017-03-01
The semiconductor industry has continually sought the approaches to produce memory devices with increased memory cells per memory die. One way to meet the increasing storage capacity demand and reduce bit cost of NAND flash memories is 3D stacked flash cell array. In constructing 3D NAND flash memories, increasing the number of stacked layers to build more memory cell number per unit area necessitates many high-aspect-ratio etching processes accordingly the incorporation of thick and unique etching hard-mask scheme has been indispensable. However, the ever increasingly thick requirement on etching hard-mask has made the hard-mask film stress control extremely important for maintaining good process qualities. The residual film stress alters the wafer shape consequently several process impacts have been readily observed across wafer, such as wafer chucking error on scanner, film peeling, materials coating and baking defects, critical dimension (CD) non-uniformity and overlay degradation. This work investigates the overlay and residual order performance indicator (ROPI) degradation coupling with increasingly thick advanced patterning film (APF) etching hard-mask. Various APF films deposited by plasma enhanced chemical vapor deposition (PECVD) method under different deposition temperatures, chemicals combinations, radio frequency powers and chamber pressures were carried out. And -342MPa to +80MPa film stress with different film thicknesses were generated for the overlay performance study. The results revealed the overlay degradation doesn't directly correlate with convex or concave wafer shapes but the magnitude of residual APF film stress, while increasing the APF thickness will worsen the overlay performance and ROPI strongly. High-stress APF film was also observed to enhance the scanner chucking difference and lead to more serious wafer to wafer overlay variation. To reduce the overlay degradation from ever increasingly thick APF etching hard-mask, optimizing the film stress of APF is the most effective way and high order overlay compensation is also helpful.
Meier, Larissa; Stange, Rainer; Michalsen, Andreas; Uehleke, Bernhard
2012-01-01
External application of clay facial masks is a cosmetic procedure generally used to reduce skin lesions and to improve overall skin condition. Collecting pilot data about self-treatment with clay jojoba oil masks on participants with acne-prone, lesioned skin and acne. Open, prospective, observational pilot study: Participants received written information, instructions, and questionnaires without direct contact with the study physician. For 6 weeks, they applied the masks 2-3 times per week. The primary outcome is the difference of skin lesions: baseline vs. after 6 weeks. 194 participants (192 female, 2 male, mean age (± SE) (32.3 ± 0.7 years) returned questionnaires and diaries. 133 of these participants returned complete and precise lesion counts (per-protocol (PP) collective). A 54% mean reduction in total lesion count was observed after 6 weeks of treatment with clay facial mask. Both inflammatory and non-inflammatory skin lesions were reduced significantly after treatment compared to baseline: Median counts (MC) of pustules per affected participant were reduced from 7.0 ± 0.9 to 3.0 ± 0.5 (mean individual reduction (MIR) = 49.4%), the MC of the papules from 3.5 ± 2.2 to 1.0 ± 0.4 (MIR = 57.3%), the MC of cysts from 2.0 ± 0.8 to 0.5 ± 0.4 (MIR = 68.6%) and the MC of comedones from 26.5 ± 6.3 to 16.0 ± 4.0 (MIR = 39.1%). DLQI-average score decreased from 5.0 ± 4.5 (mean ± SE) before to 2.1 ± 2.8 after treatment. The present study gives preliminary evidence that healing clay jojoba oil facial masks can be effective treatment for lesioned skin and mild acne vulgaris. Copyright © 2012 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Chan, Heang-Ping; Vyborny, Carl J.; MacMahon, Heber; Metz, Charles E.; Doi, Kunio; Sickles, Edward A.
1986-06-01
We have conducted a study to assess the effects of digitization and unsharp-mask filtering on the ability of observers to detect subtle microcalcifications in mammograms. Thirty-two conventional screen-film mammograms were selected from patient files by two experienced mammographers. Twelve of the mammograms contained a suspicious cluster of microcalcifications in patients who subsequently underwent biopsy. Twenty of the mammograms were normal cases which were initially interpreted as being free of clustered microcalcifications and did not demonstrate such on careful review. The mammograms were digitized with a high-quality Fuji image processing/simulation system. The system consists of two drum scanners with which an original radiograph can be digitized, processed by a minicomputer, and reconstituted on film. In this study, we employed a sampling aperture of 0.1 mm X 0.1 mm and a sampling distance of 0.1 mm. The density range from 0.2 to 2.75 was digitized to 1024 grey levels per pixel. The digitized images were printed on a single emulsion film with a display aperture having the same size as the sampling aperture. The system was carefully calibrated so that the density and contrast of a digitized image were closely matched to those of the original radiograph. Initially, we evaluated the effects of the weighting factor and the mask size of a unsharp-mask filter on the appearance of mammograms for various types of breasts. Subjective visual comparisons suggested that a mask size of 91 X 91 pixels (9.1 mm X 9.1 mm) enhances the visibility of microcalcifications without excessively increasing the high-frequency noise. Further, a density-dependent weighting factor that increases linearly from 1.5 to 3.0 in the density range of 0.2 to 2.5 enhances the contrast of microcalcifications without introducing many potentially confusing artifacts in the low-density areas. An unsharp-mask filter with these parameters was used to process the digitized mammograms. We conducted observer performance experiments to evaluate the detectability of micro-calcifications in three sets of mammograms: the original film images, unprocessed digitized images, and unsharp-masked images. Each set included the same 20 normal cases and 12 abnormal cases. A total of 5 board-certified radiologists and 4 senior radiology residents participated as observers. In the first experiment, the detectability of microcalcifications was measured for the original, unprocessed digitized, and unsharp-masked images. Each observer read all 96 films in one session with the cases arranged in a different random order. A maximum of 15 seconds was allowed to read each image. To facilitate receiver operating character-istic (ROC) analysis, each observer ranked his/her observation regarding the presence or absence of a cluster of 3 or more microcalcifications on a 5-point confidence rating scale (1=definitely no microcalcifications, 2=probably no microcalcifications; 3=microcalcifi-cations possibly present; 4=microcalcifications probably present; 5=microcalcifications definitely present). The observer identified the location of the suspected microcalci-fications when the confidence rating was 2 or greater. In the second experiment, we evaluated whether reading the unsharp-masked image and the unprocessed digitized image side by side for each case would reduce false-positive detection rates for microcalcifications and thus improve overall performance. The observer was again allowed a maximum of 15 seconds to read each pair of images and was instructed to use the unsharp-masked image for primary reading and the unprocessed digitized image for reference. The experimental setting and procedures were otherwise the same as those for the first experiment.
Auditory processing efficiency deficits in children with developmental language impairments
NASA Astrophysics Data System (ADS)
Hartley, Douglas E. H.; Moore, David R.
2002-12-01
The ``temporal processing hypothesis'' suggests that individuals with specific language impairments (SLIs) and dyslexia have severe deficits in processing rapidly presented or brief sensory information, both within the auditory and visual domains. This hypothesis has been supported through evidence that language-impaired individuals have excess auditory backward masking. This paper presents an analysis of masking results from several studies in terms of a model of temporal resolution. Results from this modeling suggest that the masking results can be better explained by an ``auditory efficiency'' hypothesis. If impaired or immature listeners have a normal temporal window, but require a higher signal-to-noise level (poor processing efficiency), this hypothesis predicts the observed small deficits in the simultaneous masking task, and the much larger deficits in backward and forward masking tasks amongst those listeners. The difference in performance on these masking tasks is predictable from the compressive nonlinearity of the basilar membrane. The model also correctly predicts that backward masking (i) is more prone to training effects, (ii) has greater inter- and intrasubject variability, and (iii) increases less with masker level than do other masking tasks. These findings provide a new perspective on the mechanisms underlying communication disorders and auditory masking.
Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.
2016-01-01
Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and nasal pillow masks for the treatment of obstructive sleep apnea. J Clin Sleep Med 2016;12(9):1263–1268. PMID:27448430
Nonadditivity of forward and simultaneous maskinga
Svec, Adam; Joshi, Suyash N.; Jesteadt, Walt
2013-01-01
The current study measured the additional masking obtained for combinations of forward and simultaneous maskers as a function of forward masker bandwidth, signal delay, and simultaneous masker level. The effects of the two individual maskers were equated in all conditions. Additional masking increased with increasing masker level, increasing signal delay, and decreasing masker bandwidth. The portion of the simultaneous masker that made the greater contribution to additional masking was the part that overlapped with the signal, not with the forward masker. The changes in additional masking observed as a function of forward masker bandwidth and the interaction between the effects of forward and simultaneous maskers call into question the use of additional masking as a measure of basilar membrane compression and present problems for the use of simultaneous noise to simulate hearing loss. PMID:24116423
Disposable surgical face masks for preventing surgical wound infection in clean surgery.
Lipp, Allyson; Edwards, Peggy
2014-02-17
Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. To determine whether disposable surgical face masks worn by the surgical team during clean surgery prevent postoperative surgical wound infection. We searched The Cochrane Wounds Group Specialised Register on 23 October 2013; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; and EBSCO CINAHL. Randomised controlled trials (RCTs) and quasi-randomised controlled trials comparing the use of disposable surgical masks with the use of no mask. Two review authors extracted data independently. Three trials were included, involving a total of 2113 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.
Subliminal number priming within and across the visual and auditory modalities.
Kouider, Sid; Dehaene, Stanislas
2009-01-01
Whether masked number priming involves a low-level sensorimotor route or an amodal semantic level of processing remains highly debated. Several alternative interpretations have been put forward, proposing either that masked number priming is solely a byproduct of practice with numbers, or that stimulus awareness was underestimated. In a series of four experiments, we studied whether repetition and congruity priming for numbers reliably extend to novel (i.e., unpracticed) stimuli and whether priming transfers from a visual prime to an auditory target, even when carefully controlling for stimulus awareness. While we consistently observed cross-modal priming, the generalization to novel stimuli was weaker and reached significance only when considering the whole set of experiments. We conclude that number priming does involve an amodal, semantic level of processing, but is also modulated by task settings.
Determining the energetic and informational components of speech-on-speech masking
Kidd, Gerald; Mason, Christine R.; Swaminathan, Jayaganesh; Roverud, Elin; Clayton, Kameron K.; Best, Virginia
2016-01-01
Identification of target speech was studied under masked conditions consisting of two or four independent speech maskers. In the reference conditions, the maskers were colocated with the target, the masker talkers were the same sex as the target, and the masker speech was intelligible. The comparison conditions, intended to provide release from masking, included different-sex target and masker talkers, time-reversal of the masker speech, and spatial separation of the maskers from the target. Significant release from masking was found for all comparison conditions. To determine whether these reductions in masking could be attributed to differences in energetic masking, ideal time-frequency segregation (ITFS) processing was applied so that the time-frequency units where the masker energy dominated the target energy were removed. The remaining target-dominated “glimpses” were reassembled as the stimulus. Speech reception thresholds measured using these resynthesized ITFS-processed stimuli were the same for the reference and comparison conditions supporting the conclusion that the amount of energetic masking across conditions was the same. These results indicated that the large release from masking found under all comparison conditions was due primarily to a reduction in informational masking. Furthermore, the large individual differences observed generally were correlated across the three masking release conditions. PMID:27475139
Masked polycythaemia vera: presenting features, response to treatment and clinical outcomes.
Alvarez-Larrán, Alberto; Angona, Anna; Ancochea, Agueda; García-Pallarols, Francesc; Fernández, Concepción; Longarón, Raquel; Bellosillo, Beatriz; Besses, Carlos
2016-01-01
Masked polycythaemia vera (PV) has been proposed as a new entity with poorer outcome than overt PV. In this study, the initial clinical and laboratory characteristics, response to treatment and outcome of masked and overt PV were compared using red cell mass and haemoglobin or haematocrit levels for the distinction between both entities. Sixty-eight of 151 PV patients (45%) were classified as masked PV according to World Health Organisation diagnostic criteria, whereas 16 (11%) were classified as masked PV using the British Committee for Standards in Haematology (BCSH). In comparison with overt PV, a higher platelet count and a lower JAK2V617F allele burden at diagnosis were observed in masked PV. Patients with masked PV needed lower phlebotomies and responded faster to hydroxcarbamide than those with overt PV. Complete haematological response was more frequently achieved in masked than in overt PV (79% vs. 58%, P = 0.001). There were no significant differences in the duration of haematological response, the rate of resistance or intolerance to hydroxycarbamide and the probability of molecular response according to type of PV (masked vs. overt). Overall survival, rate of thrombosis and major bleeding, and probability of transformation was superimposable among patients with masked and overt PV. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Discriminating between first- and second-order cognition in first-episode paranoid schizophrenia.
Bliksted, Vibeke; Samuelsen, Erla; Sandberg, Kristian; Bibby, Bo Martin; Overgaard, Morten Storm
2017-03-01
An impairment of visually perceiving backward masked stimuli is commonly observed in patients with schizophrenia, yet it is unclear whether this impairment is the result of a deficiency in first or higher order processing and for which subtypes of schizophrenia it is present. Here, we compare identification (first order) and metacognitive (higher order) performance in a visual masking paradigm between a highly homogenous group of young first-episode patients diagnosed with paranoid schizophrenia (N = 11) to that of carefully matched healthy controls (N = 13). We find no difference across groups in first-order performance, but find a difference in metacognitive performance, particularly for stimuli with relatively high visibility. These results indicate that the masking deficit is present in first-episode patients with paranoid schizophrenia, but that it is primarily an impairment of metacognition.
Palatability of a Novel Oral Formulation of Prednisone in Healthy Young Adults
Bai, Shasha; Dormer, Nathan; Shoults, Catherine; Meyer, Amanda; Pierce, Carol D'Ann; Neville, Kathleen A.; Kearns, Gregory L.
2017-01-01
Objectives Prednisone is a widely used anti-inflammatory for a variety of conditions. While oral liquid formulations of prednisone enable weight-based dosing, children frequently find them to be objectionable due to bitter taste. This limitation of prednisone can adversely impact patient acceptance and may result in non-compliance. Efforts to mask flavors often result in poorly controlled, heterogeneous particle distributions and can provide ineffective taste masking. The present work utilized a novel drug delivery technology developed by Orbis Biosciences, Inc., to create an oral taste-masked formulation of prednisone. Methods The study examined the palatability of Orbis’ microsphere prednisone formulation in healthy young adults (n=24). Four test articles were used in the study including a reference formulation (Roxane Laboratories), a control, and the test formulation (Orbis) prepared in two different ways. Study participants were randomized in a crossover design. Key Findings Results indicated that the test prednisone formulation was indistinguishable from the control, and both were preferable to the reference formulation in every category of palatability assessed using a validated 9-point Hedonic Scale. The data also suggested that preparing the microsphere suspension immediately prior to administration results in the most ideal palatability properties. Conclusions In conclusion, the novel microsphere formulation technology was effective in taste-masking prednisone. PMID:28271493
Shain, Kellen S; Madigan, Michael L; Rowson, Steven; Bisplinghoff, Jill; Duma, Stefan M
2010-11-01
The goals of this study were to measure the ability of catcher's masks to attenuate head accelerations on impact with a baseball and to compare these head accelerations to established injury thresholds for mild traumatic brain injury. Testing involved using a pneumatic cannon to shoot baseballs at an instrumented Hybrid III headform (a 50th percentile male head and neck) with and without a catcher's mask on the head. The ball speed was controlled from approximately 26.8 to 35.8 m/s (60-80 mph), and the regulation National Collegiate Athletic Association baseballs were used. Research laboratory. None. Catcher's masks and impact velocity. The linear and angular head accelerations of the Hybrid III headform. Peak linear resultant acceleration was 140 to 180 g without a mask and 16 to 30 g with a mask over the range of ball's speed investigated. Peak angular resultant acceleration was 19 500 to 25 700 rad/s without a mask and 2250 to 3230 rad/s with a mask. The Head Injury Criterion was 93 to 181 without a mask and 3 to 13 with a mask, and the Severity Index was 110 to 210 without a mask and 3 to 15 with a mask. Catcher's masks reduced head acceleration metrics by approximately 85%. Head acceleration metrics with a catcher's mask were significantly lower than contemporary injury thresholds, yet reports in the mass media clearly indicate that baseball impacts to the mask still occasionally result in mild traumatic brain injuries. Further research is needed to address this apparent contradiction.
Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A; Landry, Shane; Mansfield, Darren R; Hamilton, Garun S
2016-09-15
Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10-15.5) cm H2O compared to nasal pillow masks, 11 (8-12.5) cm H2O and nasal masks, 10 (8-12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R(2) = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5-8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.
Effects of hard mask etch on final topography of advanced phase shift masks
NASA Astrophysics Data System (ADS)
Hortenbach, Olga; Rolff, Haiko; Lajn, Alexander; Baessler, Martin
2017-07-01
Continuous shrinking of the semiconductor device dimensions demands steady improvements of the lithographic resolution on wafer level. These requirements challenge the photomask industry to further improve the mask quality in all relevant printing characteristics. In this paper topography of the Phase Shift Masks (PSM) was investigated. Effects of hard mask etch on phase shift uniformity and mask absorber profile were studied. Design of experiments method (DoE) was used for the process optimization, whereas gas composition, bias power of the hard mask main etch and bias power of the over-etch were varied. In addition, influence of the over-etch time was examined at the end of the experiment. Absorber depth uniformity, sidewall angle (SWA), reactive ion etch lag (RIE lag) and through pitch (TP) dependence were analyzed. Measurements were performed by means of Atomic-force microscopy (AFM) using critical dimension (CD) mode with a boot-shaped tip. Scanning electron microscope (SEM) cross-section images were prepared to verify the profile quality. Finally CD analysis was performed to confirm the optimal etch conditions. Significant dependence of the absorber SWA on hard mask (HM) etch conditions was observed revealing an improvement potential for the mask absorber profile. It was found that hard mask etch can leave a depth footprint in the absorber layer. Thus, the etch depth uniformity of hard mask etch is crucial for achieving a uniform phase shift over the active mask area. The optimized hard mask etch process results in significantly improved mask topography without deterioration of tight CD specifications.
Scatterometry on pelliclized masks: an option for wafer fabs
NASA Astrophysics Data System (ADS)
Gallagher, Emily; Benson, Craig; Higuchi, Masaru; Okumoto, Yasuhiro; Kwon, Michael; Yedur, Sanjay; Li, Shifang; Lee, Sangbong; Tabet, Milad
2007-03-01
Optical scatterometry-based metrology is now widely used in wafer fabs for lithography, etch, and CMP applications. This acceptance of a new metrology method occurred despite the abundance of wellestablished CD-SEM and AFM methods. It was driven by the desire to make measurements faster and with a lower cost of ownership. Over the last year, scatterometry has also been introduced in advanced mask shops for mask measurements. Binary and phase shift masks have been successfully measured at all desired points during photomask production before the pellicle is mounted. There is a significant benefit to measuring masks with the pellicle in place. From the wafer fab's perspective, through-pellicle metrology would verify mask effects on the same features that are characterized on wafer. On-site mask verification would enable quality control and trouble-shooting without returning the mask to a mask house. Another potential application is monitoring changes to mask films once the mask has been delivered to the fab (haze, oxide growth, etc.). Similar opportunities apply to the mask metrologist receiving line returns from a wafer fab. The ability to make line-return measurements without risking defect introduction is clearly attractive. This paper will evaluate the feasibility of collecting scatterometry data on pelliclized masks. We explore the effects of several different pellicle types on scatterometry measurements made with broadband light in the range of 320-780 nm. The complexity introduced by the pellicles' optical behavior will be studied.
Tickle-Degnen, Linda; Zebrowitz, Leslie A; Ma, Hui-ing
2011-07-01
Facial masking in Parkinson's disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners' responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners' impressions of patient psychological attributes. Practitioners (N = 284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners' judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners' judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners' use of facial expressivity in clinical impression formation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Tickle-Degnen, Linda; Zebrowitz, Leslie A.; Ma, Hui-ing
2011-01-01
Facial masking in Parkinson’s disease is the reduction of automatic and controlled expressive movement of facial musculature, creating an appearance of apathy, social disengagement or compromised cognitive status. Research in western cultures demonstrates that practitioners form negatively biased impressions associated with patient masking. Socio-cultural norms about facial expressivity vary according to culture and gender, yet little research has studied the effect of these factors on practitioners’ responses toward patients who vary in facial expressivity. This study evaluated the effect of masking, culture and gender on practitioners’ impressions of patient psychological attributes. Practitioners (N=284) in the United States and Taiwan judged 12 Caucasian American and 12 Asian Taiwanese women and men patients in video clips from interviews. Half of each patient group had a moderate degree of facial masking and the other half had near-normal expressivity. Practitioners in both countries judged patients with higher masking to be more depressed and less sociable, less socially supportive, and less cognitively competent than patients with lower masking. Practitioners were more biased by masking when judging the sociability of the American patients, and American practitioners’ judgments of patient sociability were more negatively biased in response to masking than were those of Taiwanese practitioners. Practitioners were more biased by masking when judging the cognitive competence and social supportiveness of the Taiwanese patients, and Taiwanese practitioners’ judgments of patient cognitive competence were more negatively biased in response to masking than were those of American practitioners. The negative response to higher masking was stronger in practitioner judgments of women than men patients, particularly American patients. The findings suggest local cultural values as well as ethnic and gender stereotypes operate on practitioners’ use of facial expressivity in clinical impression formation. PMID:21664737
Respiratory Source Control Using Surgical Masks With Nanofiber Media
Skaria, Shaji D.; Smaldone, Gerald C.
2014-01-01
Background: Potentially infected individuals (‘source’) are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others (‘receiver’). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Methods: Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of ‘infectious’ aerosols from the ‘source’ to a ‘receiver’). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an ‘N95 respirator’). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Results: Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, ‘infected’ source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Conclusions: Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. PMID:24737728
Respiratory source control using surgical masks with nanofiber media.
Skaria, Shaji D; Smaldone, Gerald C
2014-07-01
Potentially infected individuals ('source') are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others ('receiver'). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of 'infectious' aerosols from the 'source' to a 'receiver'). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an 'N95 respirator'). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, 'infected' source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Mask characterization for CDU budget breakdown in advanced EUV lithography
NASA Astrophysics Data System (ADS)
Nikolsky, Peter; Strolenberg, Chris; Nielsen, Rasmus; Nooitgedacht, Tjitte; Davydova, Natalia; Yang, Greg; Lee, Shawn; Park, Chang-Min; Kim, Insung; Yeo, Jeong-Ho
2012-11-01
As the ITRS Critical Dimension Uniformity (CDU) specification shrinks, semiconductor companies need to maintain a high yield of good wafers per day and a high performance (and hence market value) of finished products. This cannot be achieved without continuous analysis and improvement of on-product CDU as one of the main drivers for process control and optimization with better understanding of main contributors from the litho cluster: mask, process, metrology and scanner. In this paper we will demonstrate a study of mask CDU characterization and its impact on CDU Budget Breakdown (CDU BB) performed for an advanced EUV lithography with 1D and 2D feature cases. We will show that this CDU contributor is one of the main differentiators between well-known ArFi and new EUV CDU budgeting principles. We found that reticle contribution to intrafield CDU should be characterized in a specific way: mask absorber thickness fingerprints play a role comparable with reticle CDU in the total reticle part of the CDU budget. Wafer CD fingerprints, introduced by this contributor, may or may not compensate variations of mask CD's and hence influence on total mask impact on intrafield CDU at the wafer level. This will be shown on 1D and 2D feature examples in this paper. Also mask stack reflectivity variations should be taken into account: these fingerprints have visible impact on intrafield CDs at the wafer level and should be considered as another contributor to the reticle part of EUV CDU budget. We observed also MEEF-through-field fingerprints in the studied EUV cases. Variations of MEEF may also play a role for the total intrafield CDU and may be taken into account for EUV Lithography. We characterized MEEF-through-field for the reviewed features, the results to be discussed in our paper, but further analysis of this phenomenon is required. This comprehensive approach to characterization of the mask part of EUV CDU characterization delivers an accurate and integral CDU Budget Breakdown per product/process and Litho tool. The better understanding of the entire CDU budget for advanced EUVL nodes achieved by Samsung and ASML helps to extend the limits of Moore's Law and to deliver successful implementation of smaller, faster and smarter chips in semiconductor industry.
Evaluation of Decision Trees for Cloud Detection from AVHRR Data
NASA Technical Reports Server (NTRS)
Shiffman, Smadar; Nemani, Ramakrishna
2005-01-01
Automated cloud detection and tracking is an important step in assessing changes in radiation budgets associated with global climate change via remote sensing. Data products based on satellite imagery are available to the scientific community for studying trends in the Earth's atmosphere. The data products include pixel-based cloud masks that assign cloud-cover classifications to pixels. Many cloud-mask algorithms have the form of decision trees. The decision trees employ sequential tests that scientists designed based on empirical astrophysics studies and simulations. Limitations of existing cloud masks restrict our ability to accurately track changes in cloud patterns over time. In a previous study we compared automatically learned decision trees to cloud masks included in Advanced Very High Resolution Radiometer (AVHRR) data products from the year 2000. In this paper we report the replication of the study for five-year data, and for a gold standard based on surface observations performed by scientists at weather stations in the British Islands. For our sample data, the accuracy of automatically learned decision trees was greater than the accuracy of the cloud masks p < 0.001.
Kiefer, Markus; Sim, Eun-Jim; Wentura, Dirk
2015-09-01
Evaluative priming by masked emotional stimuli that are not consciously perceived has been taken as evidence that affective stimulus evaluation can also occur unconsciously. However, as masked priming effects were small and frequently observed only for familiar primes that there also presented as visible targets in an evaluative decision task, priming was thought to reflect primarily response activation based on acquired S-R associations and not evaluative semantic stimulus analysis. The present study therefore assessed across three experiments boundary conditions for the emergence of masked evaluative priming effects with unfamiliar primes in an evaluative decision task and investigated the role of the frequency of target repetition on priming with pictorial and verbal stimuli. While familiar primes elicited robust priming effects in all conditions, priming effects by unfamiliar primes were reliably obtained for low repetition (pictures) or unrepeated targets (words), but not for targets repeated at a high frequency. This suggests that unfamiliar masked stimuli only elicit evaluative priming effects when the task set associated with the visible target involves evaluative semantic analysis and is not based on S-R triggered responding as for high repetition targets. The present results therefore converge with the growing body of evidence demonstrating attentional control influences on unconscious processing. Copyright © 2015 Elsevier Inc. All rights reserved.
Optical effects of shadow masks on short circuit current of organic photovoltaic devices.
Lin, Chi-Feng; Lin, Bing-Hong; Liu, Shun-Wei; Hsu, Wei-Feng; Zhang, Mi; Chiu, Tien-Lung; Wei, Mau-Kuo; Lee, Jiun-Haw
2012-03-21
In this paper, we have employed different shadow masks attached on top of organic photovoltaic (OPV) devices to study the optical effects of the former on the short circuit current (J(SC)). To rule out possible lateral electrical conduction and simplify the optical effects inside the device, a small-molecular heterojunction OPV device with a clear donor/acceptor interface was employed with a hole extraction layer exhibiting high resistance intentionally. Careful calibration with a shadow mask was employed. By attaching two layers of opaque masks in combination with a suitable holder design to shield the light from the edges and backside, the value of J(SC) approached that of the dark current, even under 1-sun radiation. With different illumination areas, we found that the photons illuminating the non-active region of the device contributed to 40% of the J(SC) by optical effect within the width of about 1 mm around the active region. When illuminating the non-active area with 12 mm to the active area, a 5.6 times improvement in the J(SC) was observed when the incident angle was 75°. With the introduction of a microstructured film onto the OPV device and an increase in the reflection from the non-active region, a 15% enhancement of the J(SC) compared to the control device was achieved.
FPGA Control System for the Automated Test of Microshutters
NASA Technical Reports Server (NTRS)
Lyness, Eric; Rapchun, David A.; Moseley, S. Harvey
2008-01-01
The James Webb Space Telescope, scheduled to replace the Hubble in 2013, must simultaneously observe hundreds of faint galaxies. This requirement has led to the development of a programmable transmission mask which can be adapted to admit light with arbitrary pattern of galaxies into its spectrograph. This programmable mask will contain a large array of micro-electromechanical (MEMs) devices called MicroShutters. These microscopic shutters physically open and close like the shutter on a camera, except each shutter is microscopic in size and an array 365 by 171 is used to select the objects under spectroscopic observation at a given time, and to block the unwanted background light from other areas. NASA developed and is currently refining the exceptionally difficult process of manufacturing these shutters. This paper describes how the authors used LabVIEW FPGA and a reconfigurable I/O board to control the shutters in a test chamber and how the flexibility of the system allows us to continue to modify the control algorithms as NASA optimizes the performance of the MicroShutter arrays.
FPGA Control System for the Automated Test of MicroShutters
NASA Technical Reports Server (NTRS)
Lyness, Eric; Rapchun, David A.; Moseley, S. Harvey
2008-01-01
The James Webb Space Telescope, scheduled to replace the Hubble in 2013, must simultaneously observe hundreds of faint galaxies. This requirement has led to the development of a programmable transmission mask which can be adapted to admit light from an arbitrary pattern of galaxies into its spectrograph. This programmable mask will contain a large array of micro-electromechanical (MEMs) devices called MicroShutters. These microscopic shutters physically open and close like the shutter on a camera, except each shutter is microscopic in size and an array 365 by 171 is used to select the objects under spectroscopic observation at a given time, and to block the unwanted background light from other areas. NASA developed and is currently refining the exceptionally difficult process of manufacturing these shutters. This paper describes how the authors used LabVIEW FPGA and a reconfigurable I/O board to control the shutters in a test chamber and how the flexibility of the system allows us to continue to modify the control algorithms as NASA optimizes the performance of the MicroShutter arrays.
Improved mask-based CD uniformity for gridded-design-rule lithography
NASA Astrophysics Data System (ADS)
Faivishevsky, Lev; Khristo, Sergey; Sagiv, Amir; Mangan, Shmoolik
2009-03-01
The difficulties encountered during lithography of state-of-the-art 2D patterns are formidable, and originate from the fact that deep sub-wavelength features are being printed. This results in a practical limit of k1 >=0.4 as well as a multitude of complex restrictive design rules, in order to mitigate or minimize lithographic hot spots. An alternative approach, that is gradually attracting the lithographic community's attention, restricts the design of critical layers to straight, dense lines (a 1D grid), that can be relatively easily printed using current lithographic technology. This is then followed by subsequent, less critical trimming stages to obtain circuit functionality. Thus, the 1D gridded approach allows hotspot-free, proximity-effect free lithography of ultra low- k1 features. These advantages must be supported by a stable CD control mechanism. One of the overriding parameters impacting CDU performance is photo mask quality. Previous publications have demonstrated that IntenCDTM - a novel, mask-based CDU mapping technology running on Applied Materials' Aera2TM aerial imaging mask inspection tool - is ideally fit for detecting mask-based CDU issues in 1D (L&S) patterned masks for memory production. Owing to the aerial nature of image formation, IntenCD directly probes the CD as it is printed on the wafer. In this paper we suggest that IntenCD is naturally fit for detecting mask-based CDU issues in 1D GDR masks. We then study a novel method of recovering and quantifying the physical source of printed CDU, using a novel implementation of the IntenCD technology. We demonstrate that additional, simple measurements, which can be readily performed on board the Aera2TM platform with minimal throughput penalty, may complement IntenCD and allow a robust estimation of the specific nature and strength of mask error source, such as pattern width variation or phase variation, which leads to CDU issues on the printed wafer. We finally discuss the roles played by IntenCD in advanced GDR mask production, starting with tight control over mask production process, continuing to mask qualification at mask shop and ending at in-line wafer CDU correction in fabs.
More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies
Amirav, Israel; Halamish, Asaf; Gorenberg, Miguel; Omar, Hamza; Newhouse, Michael T.
2015-01-01
Background Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic “face” surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. Aim To compare mask to “face” seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. Methods Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the “face.” Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. Results The soft “face” significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft “face” was significantly greater for the SM compared to the AC (p< 0.01). No statistically significant difference between the two masks was observed with the hard “face.” Conclusions The material and pliability of the model “face” surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies. PMID:26090661
A novel anti-influenza copper oxide containing respiratory face mask.
Borkow, Gadi; Zhou, Steve S; Page, Tom; Gabbay, Jeffrey
2010-06-25
Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10)TCID(50) of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (< or = 0.88 log(10)TCID(50)), while 4.67+/-1.35 log(10)TCID(50) were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were < or = 0.97+/-0.01 log(10)TCID(50) and from the control masks 5.03+/-0.54 log(10)TCID(50). The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks.
Czyżewski, Łukasz; Wyzgał, Janusz; Kołek, Anna
2014-04-28
Arterial hypertension is a donor-related and modifiable risk factor in a graft dysfunction. The aim of the study was to perform a multi-factor analysis describing the relations between arterial hypertension and clinical parameters of a graft recipient. Fifty patients 3 months after a kidney transplant took part in the study. The following research tools were used: (1) 24-hour Ambulatory Blood Pressure Monitoring, ABPM; (2) traditional method - office BP; (3) the authors' questionnaire form, (4) Morisky-Green test for self-evaluation of the compliance level; (5) disease history. The relevance level was p<0.05. ABPM results showed that only 8 (16%) renal transplant recipients are normotensive without any antihypertensive drugs. It was shown through ABPM that insufficient controlling of hypertension was observed in 22 patients (44%). It was shown that 9 patients (18%) had masked hypertension and 5 patients (10%) white-coat hypertension. Eight patients (16%) showed controlled daily rhythm of blood pressure ("dippers"). No statistically significant correlation between ABPM and office BP and creatinine level was observed. The results of the study show insufficient control of arterial hypertension and the occurrence of masked hypertension and the white-coat effect in patients after KTx. ABPM should be routinely performed in post-KTx patients. Nonadherence to regular taking of medication and improper lifestyle of patients in the third month after KTx are not a risk factor in higher values of arterial hypertension and higher level of creatinine.
Nasal mask ventilation is better than face mask ventilation in edentulous patients
Kapoor, Mukul Chandra; Rana, Sandeep; Singh, Arvind Kumar; Vishal, Vindhya; Sikdar, Indranil
2016-01-01
Background and Aims: Face mask ventilation of the edentulous patient is often difficult as ineffective seating of the standard mask to the face prevents attainment of an adequate air seal. The efficacy of nasal ventilation in edentulous patients has been cited in case reports but has never been investigated. Material and Methods: Consecutive edentulous adult patients scheduled for surgery under general anesthesia with endotracheal intubation, during a 17-month period, were prospectively evaluated. After induction of anesthesia and administration of neuromuscular blocker, lungs were ventilated with a standard anatomical face mask of appropriate size, using a volume controlled anesthesia ventilator with tidal volume set at 10 ml/kg. In case of inadequate ventilation, the mask position was adjusted to achieve best-fit. Inspired and expired tidal volumes were measured. Thereafter, the face mask was replaced by a nasal mask and after achieving best-fit, the inspired and expired tidal volumes were recorded. The difference in expired tidal volumes and airway pressures at best-fit with the use of the two masks and number of patients with inadequate ventilation with use of the masks were statistically analyzed. Results: A total of 79 edentulous patients were recruited for the study. The difference in expiratory tidal volumes with the use of the two masks at best-fit was statistically significant (P = 0.0017). Despite the best-fit mask placement, adequacy of ventilation could not be achieved in 24.1% patients during face mask ventilation, and 12.7% patients during nasal mask ventilation and the difference was statistically significant. Conclusion: Nasal mask ventilation is more efficient than standard face mask ventilation in edentulous patients. PMID:27625477
Shadows Alter Facial Expressions of Noh Masks
Kawai, Nobuyuki; Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo
2013-01-01
Background A Noh mask, worn by expert actors during performance on the Japanese traditional Noh drama, conveys various emotional expressions despite its fixed physical properties. How does the mask change its expressions? Shadows change subtly during the actual Noh drama, which plays a key role in creating elusive artistic enchantment. We here describe evidence from two experiments regarding how attached shadows of the Noh masks influence the observers’ recognition of the emotional expressions. Methodology/Principal Findings In Experiment 1, neutral-faced Noh masks having the attached shadows of the happy/sad masks were recognized as bearing happy/sad expressions, respectively. This was true for all four types of masks each of which represented a character differing in sex and age, even though the original characteristics of the masks also greatly influenced the evaluation of emotions. Experiment 2 further revealed that frontal Noh mask images having shadows of upward/downward tilted masks were evaluated as sad/happy, respectively. This was consistent with outcomes from preceding studies using actually tilted Noh mask images. Conclusions/Significance Results from the two experiments concur that purely manipulating attached shadows of the different types of Noh masks significantly alters the emotion recognition. These findings go in line with the mysterious facial expressions observed in Western paintings, such as the elusive qualities of Mona Lisa’s smile. They also agree with the aesthetic principle of Japanese traditional art “yugen (profound grace and subtlety)”, which highly appreciates subtle emotional expressions in the darkness. PMID:23940748
Full-chip level MEEF analysis using model based lithography verification
NASA Astrophysics Data System (ADS)
Kim, Juhwan; Wang, Lantian; Zhang, Daniel; Tang, Zongwu
2005-11-01
MEEF (Mask Error Enhancement Factor) has become a critical factor in CD uniformity control since optical lithography process moved to sub-resolution era. A lot of studies have been done by quantifying the impact of the mask CD (Critical Dimension) errors on the wafer CD errors1-2. However, the benefits from those studies were restricted only to small pattern areas of the full-chip data due to long simulation time. As fast turn around time can be achieved for the complicated verifications on very large data by linearly scalable distributed processing technology, model-based lithography verification becomes feasible for various types of applications such as post mask synthesis data sign off for mask tape out in production and lithography process development with full-chip data3,4,5. In this study, we introduced two useful methodologies for the full-chip level verification of mask error impact on wafer lithography patterning process. One methodology is to check MEEF distribution in addition to CD distribution through process window, which can be used for RET/OPC optimization at R&D stage. The other is to check mask error sensitivity on potential pinch and bridge hotspots through lithography process variation, where the outputs can be passed on to Mask CD metrology to add CD measurements on those hotspot locations. Two different OPC data were compared using the two methodologies in this study.
Neural Correlates of the Lombard Effect in Primate Auditory Cortex
Eliades, Steven J.
2012-01-01
Speaking is a sensory-motor process that involves constant self-monitoring to ensure accurate vocal production. Self-monitoring of vocal feedback allows rapid adjustment to correct perceived differences between intended and produced vocalizations. One important behavior in vocal feedback control is a compensatory increase in vocal intensity in response to noise masking during vocal production, commonly referred to as the Lombard effect. This behavior requires mechanisms for continuously monitoring auditory feedback during speaking. However, the underlying neural mechanisms are poorly understood. Here we show that when marmoset monkeys vocalize in the presence of masking noise that disrupts vocal feedback, the compensatory increase in vocal intensity is accompanied by a shift in auditory cortex activity toward neural response patterns seen during vocalizations under normal feedback condition. Furthermore, we show that neural activity in auditory cortex during a vocalization phrase predicts vocal intensity compensation in subsequent phrases. These observations demonstrate that the auditory cortex participates in self-monitoring during the Lombard effect, and may play a role in the compensation of noise masking during feedback-mediated vocal control. PMID:22855821
Victor, Teresa A; Furey, Maura L; Fromm, Stephen J; Bellgowan, Patrick S F; Öhman, Arne; Drevets, Wayne C
2012-01-01
Major depressive disorder (MDD) is associated with a mood-congruent processing bias in the amygdala toward face stimuli portraying sad expressions that is evident even when such stimuli are presented below the level of conscious awareness. The extended functional anatomical network that maintains this response bias has not been established, however. To identify neural network differences in the hemodynamic response to implicitly presented facial expressions between depressed and healthy control participants. Unmedicated-depressed participants with MDD (n=22) and healthy controls (HC; n=25) underwent functional MRI as they viewed face stimuli showing sad, happy or neutral face expressions, presented using a backward masking design. The blood-oxygen-level dependent (BOLD) signal was measured to identify regions where the hemodynamic response to the emotionally valenced stimuli differed between groups. The MDD subjects showed greater BOLD responses than the controls to masked-sad versus masked-happy faces in the hippocampus, amygdala and anterior inferotemporal cortex. While viewing both masked-sad and masked-happy faces relative to masked-neutral faces, the depressed subjects showed greater hemodynamic responses than the controls in a network that included the medial and orbital prefrontal cortices and anterior temporal cortex. Depressed and healthy participants showed distinct hemodynamic responses to masked-sad and masked-happy faces in neural circuits known to support the processing of emotionally valenced stimuli and to integrate the sensory and visceromotor aspects of emotional behavior. Altered function within these networks in MDD may establish and maintain illness-associated differences in the salience of sensory/social stimuli, such that attention is biased toward negative and away from positive stimuli.
Polarization masks: concept and initial assessment
NASA Astrophysics Data System (ADS)
Lam, Michael; Neureuther, Andrew R.
2002-07-01
Polarization from photomasks can be used as a new lever to improve lithographic performance in both binary and phase-shifting masks (PSMs). While PSMs manipulate the phase of light to control the temporal addition of electric field vectors, polarization masks manipulate the vector direction of electric field vectors to control the spatial addition of electric field components. This paper explores the theoretical possibilities of polarization masks, showing that it is possible to use bar structures within openings on the mask itself to polarize incident radiation. Rigorous electromagnetic scattering simulations using TEMPEST and imaging with SPLAT are used to give an initial assessment on the functionality of polarization masks, discussing the polarization quality and throughputs achieved with the masks. Openings between 1/8 and 1/3 of a wavelength provide both a low polarization ratio and good transmission. A final overall throughput of 33% - 40% is achievable, corresponding to a dose hit of 2.5x - 3x.
Niño, Maria C; Pauwels, Andres; Raffan, Fernando; Arango, Enrique; Romero, David J; Benitez, Daniel
2017-04-01
Mask ventilation is routinely performed during anesthesia. Under some circumstances, it might be difficult to perform, such as in edentulous patients, due to inadequate mask seal. We developed a new device called NIPARA and studied its use For ventilation optimization in edentulous patients. This randomized controlled trial included edentulous adults who had no other predictors of difficult airway, scheduled to undergo general anesthesia. Patients were assigned either to the NIPARA device group or to the control group (oral airway only). The primary outcomes were peak inspiratory pressure and tidal volume values of the first 14 breaths. The secondary outcome was the incidence of complications. Data from 37 patients were collected during a one-year period (twenty in the NIPARA device group and 17 in the control group). The difference in mean PIP was not statistically significant. The tidal volume was 1.5 times greater in the NIPARA group than in the control group. One patient from the intervention group had minimal oral trauma. In the administration of face mask ventilation, NIPARA is an effective device that significantly improves the tidal volume administered in edentulous patients.
Physical interventions to interrupt or reduce the spread of respiratory viruses: systematic review
2008-01-01
Objective To systematically review evidence for the effectiveness of physical interventions to interrupt or reduce the spread of respiratory viruses. Data extraction Search strategy of the Cochrane Library, Medline, OldMedline, Embase, and CINAHL, without language restriction, for any intervention to prevent transmission of respiratory viruses (isolation, quarantine, social distancing, barriers, personal protection, and hygiene). Study designs were randomised trials, cohort studies, case-control studies, and controlled before and after studies. Data synthesis Of 2300 titles scanned 138 full papers were retrieved, including 49 papers of 51 studies. Study quality was poor for the three randomised controlled trials and most of the cluster randomised controlled trials; the observational studies were of mixed quality. Heterogeneity precluded meta-analysis of most data except that from six case-control studies. The highest quality cluster randomised trials suggest that the spread of respiratory viruses into the community can be prevented by intervening with hygienic measures aimed at younger children. Meta-analysis of six case-control studies suggests that physical measures are highly effective in preventing the spread of SARS: handwashing more than 10 times daily (odds ratio 0.45, 95% confidence interval 0.36 to 0.57; number needed to treat=4, 95% confidence interval 3.65 to 5.52); wearing masks (0.32, 0.25 to 0.40; NNT=6, 4.54 to 8.03); wearing N95 masks (0.09, 0.03 to 0.30; NNT=3, 2.37 to 4.06); wearing gloves (0.43, 0.29 to 0.65; NNT=5, 4.15 to 15.41); wearing gowns (0.23, 0.14 to 0.37; NNT=5, 3.37 to 7.12); and handwashing, masks, gloves, and gowns combined (0.09, 0.02 to 0.35; NNT=3, 2.66 to 4.97). The incremental effect of adding virucidals or antiseptics to normal handwashing to decrease the spread of respiratory disease remains uncertain. The lack of proper evaluation of global measures such as screening at entry ports and social distancing prevent firm conclusions being drawn. Conclusion Routine long term implementation of some physical measures to interrupt or reduce the spread of respiratory viruses might be difficult but many simple and low cost interventions could be useful in reducing the spread. PMID:18042961
In-die mask registration measurement on 28nm-node and beyond
NASA Astrophysics Data System (ADS)
Chen, Shen Hung; Cheng, Yung Feng; Chen, Ming Jui
2013-09-01
As semiconductor go to smaller node, the critical dimension (CD) of process become more and more small. For lithography, RET (Resolution Enhancement Technology) applications can be used for wafer printing of smaller CD/pitch on 28nm node and beyond. SMO (Source Mask Optimization), DPT (Double Patterning Technology) and SADP (Self-Align Double Patterning) can provide lower k1 value for lithography. In another way, image placement error and overlay control also become more and more important for smaller chip size (advanced node). Mask registration (image placement error) and mask overlay are important factors to affect wafer overlay control/performance especially for DPT or SADP. In traditional method, the designed registration marks (cross type, square type) with larger CD were put into scribe-line of mask frame for registration and overlay measurement. However, these patterns are far way from real patterns. It does not show the registration of real pattern directly and is not a convincing method. In this study, the in-die (in-chip) registration measurement is introduced. We extract the dummy patterns that are close to main pattern from post-OPC (Optical Proximity Correction) gds by our desired rule and choose the patterns that distribute over whole mask uniformly. The convergence test shows 100 points measurement has a reliable result.
Ari, Seyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Caca, Ihsan
2009-08-01
The most common cause for the failure of external dacryocystorhinostomy (DCR) surgery is the formation of granulation tissue at the osteotomy site or common canaliculus. The aims of this study were to assess the efficacy of intraoperative adjunctive mitomycin C (MMC) treatment in external DCR surgery and to compare this procedure with the standard DCR procedure alone in the long term (1 year). In this prospective, double-masked, randomized, controlled trial, patients with primary acquired nasolacrimal duct obstruction were randomized (using a random number table) into 2 groups based on surgical procedure. In the MMC group, intraoperative adjunctive MMC 0.2 mg/mL was applied to the osteotomy site for 30 minutes. The control group underwent standard DCR procedure only. The results of the DCR surgeries were assessed using objective findings (eg, cessation of excessive tearing via nasolacrimal duct irrigation and the improvement in height of tear meniscus) and subjective symptoms (asking patients to describe the degree of tearing improvement). Both the patients and the researchers who were assessing the study outcomes were masked to treatment group. One hundred eyes of 100 Turkish patients were assessed and equally randomized to the MMC (27 women, 23 men; mean [SD] age, 47.0 [7.6] years) and control (26 women, 24 men; mean age, 46.6 [8.8] years) groups. The follow-up period was not significantly different between the MMC and the control groups (13.1 [1.1] vs 13.2 [1.4] months). Significantly more eyes in the MMC group than the control group remained symptom-free throughout the 1-year follow-up period (45/50 [90%] vs 33/50 [66%]; P=0.005). Significantly more patients in the control group than the MMC group had an improvement in symptoms at the 1-year follow-up (8/50 [16%] vs 2/50 [4%] eyes; P=0.005). Based on the patency of the drainage system, the success rate was significantly greater in the MMC group than the control group (48/50 [96%] vs 42/50 [84%]; P=0.005). Based on nasolacrimal duct irrigation, significantly fewer patients in the MMC group than the control group had an enclosed naso-lacrimal duct (2/50 [4%] vs 8/50 [16%]). No adverse effects (eg, abnormal nasal bleeding, mucosal necrosis, infection) or any other surgical adverse events were observed. In the management of these patients with primary acquired nasolacrimal duct obstruction, adjunctive intraoperative MMC application with standard DCR surgery had a significantly higher success rate than did standard DCR surgery alone. Further large, double-masked, randomized studies are needed to confirm these findings.
Ari, Şeyhmus; Gun, Ramazan; Surmeli, Serdar; Atay, Ahmet Engin; Çaca, Îhsan
2009-01-01
Background: The most common cause for the failure of external dacryocystorhinostomy (DCR) surgery is the formation of granulation tissue at the osteotomy site or common canaliculus. Objectives: The aims of this study were to assess the efficacy of intraoperative adjunctive mitomycin C (MMC) treatment in external DCR surgery and to compare this procedure with the standard DCR procedure alone in the long term (1 year). Methods: In this prospective, double-masked, randomized, controlled trial, patients with primary acquired nasolacrimal duct obstruction were randomized (using a random number table) into 2 groups based on surgical procedure. In the MMC group, intraoperative adjunctive MMC 0.2 mg/mL was applied to the osteotomy site for 30 minutes. The control group underwent standard DCR procedure only. The results of the DCR surgeries were assessed using objective findings (eg, cessation of excessive tearing via nasolacrimal duct irrigation and the improvement in height of tear meniscus) and subjective symptoms (asking patients to describe the degree of tearing improvement). Both the patients and the researchers who were assessing the study outcomes were masked to treatment group. Results: One hundred eyes of 100 Turkish patients were assessed and equally randomized to the MMC (27 women, 23 men; mean [SD] age, 47.0 [7.6] years) and control (26 women, 24 men; mean age, 46.6 [8.8] years) groups. The follow-up period was not significantly different between the MMC and the control groups (13.1 [1.1] vs 13.2 [1.4] months). Significantly more eyes in the MMC group than the control group remained symptom-free throughout the 1-year follow-up period (45/50 [90%] vs 33/50 [66%]; P=0.005). Significantly more patients in the control group than the MMC group had an improvement in symptoms at the 1-year follow-up (8/50 [16%] vs 2/50 [4%] eyes; P=0.005). Based on the patency of the drainage system, the success rate was significantly greater in the MMC group than the control group (48/50 [96%] vs 42/50 [84%]; P=0.005). Based on nasolacrimal duct irrigation, significantly fewer patients in the MMC group than the control group had an enclosed naso-lacrimal duct (2/50 [4%] vs 8/50 [16%]). No adverse effects (eg, abnormal nasal bleeding, mucosal necrosis, infection) or any other surgical adverse events were observed. Conclusions: In the management of these patients with primary acquired nasolacrimal duct obstruction, adjunctive intraoperative MMC application with standard DCR surgery had a significantly higher success rate than did standard DCR surgery alone. Further large, double-masked, randomized studies are needed to confirm these findings. PMID:24683236
Perceptual learning for speech in noise after application of binary time-frequency masks
Ahmadi, Mahnaz; Gross, Vauna L.; Sinex, Donal G.
2013-01-01
Ideal time-frequency (TF) masks can reject noise and improve the recognition of speech-noise mixtures. An ideal TF mask is constructed with prior knowledge of the target speech signal. The intelligibility of a processed speech-noise mixture depends upon the threshold criterion used to define the TF mask. The study reported here assessed the effect of training on the recognition of speech in noise after processing by ideal TF masks that did not restore perfect speech intelligibility. Two groups of listeners with normal hearing listened to speech-noise mixtures processed by TF masks calculated with different threshold criteria. For each group, a threshold criterion that initially produced word recognition scores between 0.56–0.69 was chosen for training. Listeners practiced with one set of TF-masked sentences until their word recognition performance approached asymptote. Perceptual learning was quantified by comparing word-recognition scores in the first and last training sessions. Word recognition scores improved with practice for all listeners with the greatest improvement observed for the same materials used in training. PMID:23464038
Victor, Teresa A; Drevets, Wayne C; Misaki, Masaya; Bodurka, Jerzy; Savitz, Jonathan
2017-01-02
Twice as many women as men suffer from mood and anxiety disorders, yet the biological underpinnings of this phenomenon have been understudied and remain unclear. We and others have shown that the hemodynamic response to subliminally presented sad or happy faces during functional MRI (fMRI) is a robust biomarker for the attentional bias toward negative information classically observed in major depression. Here we used fMRI to compare the performance of healthy females (n = 28) and healthy males (n = 28) on a backward masking task using a fast event-related design with gradient-recalled, echoplanar imaging with sensitivity encoding. The image data were compared across groups using a region-of-interest analysis with small-volume correction to control for multiple testing (P corrected < 0.05, cluster size ≥ 20 voxels). Notably, compared with males, females showed greater BOLD activity in the subgenual anterior cingulate cortex (sgACC) and the right hippocampus when viewing masked sad vs. masked happy faces. Furthermore, females displayed reduced BOLD activity in the right pregenual ACC and left amygdala when viewing masked happy vs. masked neutral faces. Given that we have previously reported similar findings for depressed participants compared with healthy controls (regardless of gender), our results raise the possibility that on average healthy females show subtle emotional processing biases that conceivably reflect a subgroup of women predisposed to depression. Nevertheless, we note that the differences between males and females were small and derived from region-of-interest rather than voxelwise analyses. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Murakami, Naoshi; Nishikawa, Jun; Sakamoto, Moritsugu; Ise, Akitoshi; Oka, Kazuhiko; Baba, Naoshi; Murakami, Hiroshi; Tamura, Motohide; Traub, Wesley A.; Mawet, Dimitri;
2012-01-01
Photonic crystal, an artificial periodic nanostructure of refractive indices, is one of the attractive technologies for coronagraph focal-plane masks aiming at direct imaging and characterization of terrestrial extrasolar planets. We manufactured the eight-octant phase mask (8OPM) and the vector vortex mask (VVM) very precisely using the photonic crystal technology. Fully achromatic phase-mask coronagraphs can be realized by applying appropriate polarization filters to the masks. We carried out laboratory experiments of the polarization-filtered 8OPM coronagraph using the High-Contrast Imaging Testbed (HCIT), a state-of-the-art coronagraph simulator at the Jet Propulsion Laboratory (JPL). We report the experimental results of 10-8-level contrast across several wavelengths over 10% bandwidth around 800nm. In addition, we present future prospects and observational strategy for the photonic-crystal mask coronagraphs combined with differential imaging techniques to reach higher contrast. We proposed to apply a polarization-differential imaging (PDI) technique to the VVM coronagraph, in which we built a two-channel coronagraph using polarizing beam splitters to avoid a loss of intensity due to the polarization filters. We also proposed to apply an angular-differential imaging (ADI) technique to the 8OPM coronagraph. The 8OPM/ADI mode avoids an intensity loss due to a phase transition of the mask and provides a full field of view around central stars. We present results of preliminary laboratory demonstrations of the PDI and ADI observational modes with the phase-mask coronagraphs.
Foul tip impact attenuation of baseball catcher masks using head impact metrics
White, Terrance R.; Cutcliffe, Hattie C.; Shridharani, Jay K.; Wood, Garrett W.; Bass, Cameron R.
2018-01-01
Currently, no scientific consensus exists on the relative safety of catcher mask styles and materials. Due to differences in mass and material properties, the style and material of a catcher mask influences the impact metrics observed during simulated foul ball impacts. The catcher surrogate was a Hybrid III head and neck equipped with a six degree of freedom sensor package to obtain linear accelerations and angular rates. Four mask styles were impacted using an air cannon for six 30 m/s and six 35 m/s impacts to the nasion. To quantify impact severity, the metrics peak linear acceleration, peak angular acceleration, Head Injury Criterion, Head Impact Power, and Gadd Severity Index were used. An Analysis of Covariance and a Tukey’s HSD Test were conducted to compare the least squares mean between masks for each head injury metric. For each injury metric a P-Value less than 0.05 was found indicating a significant difference in mask performance. Tukey’s HSD test found for each metric, the traditional style titanium mask fell in the lowest performance category while the hockey style mask was in the highest performance category. Limitations of this study prevented a direct correlation from mask testing performance to mild traumatic brain injury. PMID:29856814
MC1R studies in dogs with melanistic mask or brindle patterns.
Schmutz, S M; Berryere, T G; Ellinwood, N M; Kerns, J A; Barsh, G S
2003-01-01
Black mask is a characteristic pattern in which red, yellow, tan, fawn, or brindle dogs exhibit a melanistic muzzle which may extend up onto the ears. Melanistic mask is inherited in several breeds as an autosomal dominant trait, and appears to be a fixed trait in a few breeds of dogs. A MC1R nonsense mutation, R306ter, has been shown to cause a completely red or yellow coat color in certain breeds such as Irish setters, yellow Labrador retrievers, and golden retrievers. The amino acid sequence for the melanocortin receptor 1 gene (MC1R) was examined in 17 dogs with melanistic masks from seven breeds, 19 dogs without melanistic masks, and 7 dogs in which their coat color made the mask difficult to distinguish. We also examined nine brindle dogs of four breeds, including three dogs who also had a black mask. No consistent amino acid change was observed in the brindle dogs. All dogs with a melanistic mask had at least one copy of a valine substitution for methionine at amino acid 264 (M264V) and none were homozygous for the premature stop codon (R306ter). These results suggest that black mask, but not brindle, is caused by a specific MC1R allele.
Assessment of molecular contamination in mask pod
NASA Astrophysics Data System (ADS)
Foray, Jean Marie; Dejaune, Patrice; Sergent, Pierre; Gough, Stuart; Cheung, D.; Davenet, Magali; Favre, Arnaud; Rude, C.; Trautmann, T.; Tissier, Michel; Fontaine, H.; Veillerot, M.; Avary, K.; Hollein, I.; Lerit, R.
2008-04-01
Context/ study Motivation: Contamination and especially Airbone Molecular Contamination (AMC) is a critical issue for mask material flow with a severe and fairly unpredictable risk of induced contamination and damages especially for 193 nm lithography. It is therefore essential to measure, to understand and then try to reduce AMC in mask environment. Mask material flow was studied in a global approach by a pool of European partners, especially within the frame of European MEDEA+ project, so called "MUSCLE". This paper deals with results and assessment of mask pod environment in term of molecular contamination in a first step, then in a second step preliminary studies to reduce mask pod influence and contamination due to material out gassing. Approach and techniques: A specific assessment of environmental / molecular contamination along the supply chain was performed by all partners. After previous work presented at EMLC 07, further studies were performed on real time contamination measurement pod at different sites locations (including Mask manufacturing site, blank manufacturing sites, IC fab). Studies were linked to the main critical issues: cleaning, storage, handling, materials and processes. Contamination measurement campaigns were carried out along the mask supply chain using specific Adixen analyzer in order to monitor in real time organic contaminants (ppb level) in mask pods. Key results would be presented: VOC, AMC and humidity level on different kinds of mask carriers, impact of basic cleaning on pod outgassing measurement (VOC, NH3), and process influence on pod contamination... In a second step, preliminary specific pod conditioning studies for better pod environment were performed based on Adixen vacuum process. Process influence had been experimentally measured in term of molecular outgassing from mask pods. Different AMC experimental characterization methods had been carried out leading to results on a wide range of organic and inorganic contaminants: by inline techniques based on Adixen humidity, also VOC and organic sensors, together by off-line techniques already used in the extensive previous mask pods benchmark (TD-GCMS & Ionic Chromatography). Humidity and VOC levels from mask carriers had shown significant reduction after Adixen pod conditioning process. Focus had been made on optimized vacuum step (for AMC) after particles carrier cleaning cycle. Based upon these key results new procedures, as well as guidelines for mask carrier cleaning optimization are proposed to improve pod contamination control. Summary results/next steps: This paper reports molecular contamination measurement campaigns performed by a pool of European partners along the mask supply chain. It allows us to investigate, identify and quantify critical molecular contamination in mask pod, as well as VOC and humidity, issues depending on locations, uses, and carrier's type. Preliminary studies highlight initial process solutions for pods conditioning that are being used for short term industrialization and further industrialized.
ERIC Educational Resources Information Center
Hall, Joseph W.; Grose, John H.
1993-01-01
This study of 14 children (ages 5-9) with a history of otitis media with effusion found that subjects had significantly reduced masking-level differences (MLD) compared to controls. Results suggest that the reduction in MLD may be related to abnormal brainstem processing. (Author/JDD)
Informational Masking and Spatial Hearing in Listeners with and without Unilateral Hearing Loss
ERIC Educational Resources Information Center
Rothpletz, Ann M.; Wightman, Frederic L.; Kistler, Doris J.
2012-01-01
Purpose: This study assessed selective listening for speech in individuals with and without unilateral hearing loss (UHL) and the potential relationship between spatial release from informational masking and localization ability in listeners with UHL. Method: Twelve adults with UHL and 12 normal-hearing controls completed a series of monaural and…
Short-term visual deprivation can enhance spatial release from masking.
Pagé, Sara; Sharp, Andréanne; Landry, Simon P; Champoux, François
2016-08-15
This research aims to study the effect of short-term visual deprivation on spatial release from masking, a major component of the cocktail party effect that allows people to detect an auditory target in noise. The Masking Level Difference (MLD) test was administered on healthy individuals over three sessions: before (I) and after 90min of visual deprivation (II), and after 90min of re-exposure to light (III). A non-deprived control group performed the same tests, but remained sighted between sessions I and II. The non-deprived control group displayed constant results across sessions. However, performance in the MLD test was improved following short-term visual deprivation and performance returned to pre-deprivation values after light re-exposure. This study finds that short-term visual deprivation transiently enhances the spatial release from masking. These data suggest the significant potential for enhancing a process involved in the cocktail party effect in normally developing individuals and adds to an emerging literature on the potential to enhance auditory ability after only a brief period of visual deprivation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Are Masking-Based Models of Risk Useful?
Gisiner, Robert C
2016-01-01
As our understanding of directly observable effects from anthropogenic sound exposure has improved, concern about "unobservable" effects such as stress and masking have received greater attention. Equal energy models of masking such as power spectrum models have the appeal of simplicity, but do they offer biologically realistic assessments of the risk of masking? Data relevant to masking such as critical ratios, critical bandwidths, temporal resolution, and directional resolution along with what is known about general mammalian antimasking mechanisms all argue for a much more complicated view of masking when making decisions about the risk of masking inherent in a given anthropogenic sound exposure scenario.
Sah, Hulya Kahraman; Akcil, Eren Fatma; Tunali, Yusuf; Vehid, Hayriye; Dilmen, Ozlem Korkmaz
2017-11-01
Volume controlled ventilation with low PEEP is used in neuro-anesthesia to provide constant PaCO 2 levels and prevent raised intracranial pressure. Therefore, neurosurgery patients prone to atelectasis formation, however, we could not find any study that evaluates prevention of postoperative pulmonary complications in neurosurgery. A prospective, randomized controlled study. Intensive care unit in a university hospital in Istanbul. Seventy-nine ASAI-II patients aged between 18 and 70years scheduled for elective supratentorial craniotomy were included in the study. Patients randomized into 3 groups after surgery. The Group IS (n=20) was treated with incentive spirometry 5 times in 1min and 5min per hour, the Group CPAP (n=20) with continuous positive airway pressure 10 cmH 2 O pressure and 0.4 F i O 2 via an oronasal mask 5min per hour, and the Group Control (n=20) 4L·min -1 O 2 via mask; all during the first 6h postoperatively. Respiratory functions tests and arterial blood gases analysis were performed before the induction of anesthesia (Baseline), 30min, 6h, 24h postoperatively. The IS and CPAP applications have similar effects with respect to FVC values. The postoperative 30min FEV 1 values were statistically significantly reduced compared to the Baseline in all groups (p<0.0001). FEV 1 values were statistically significantly increased at the postoperative 24h compared to the postoperative 30min in the Groups IS and CPAP (p<0.0001). This increase, however, was not observed in the Group Control, and the postoperative 24h FEV 1 values were statistically significantly lower in the Group Control compared to the Group IS (p=0.015). Although this study is underpowered to detect differences in FEV 1 values, the postoperative 24h FEV 1 values were significantly higher in the IS group than the Control group and this difference was not observed between the CPAP and Control groups. It might be evaluate a favorable effect of IS in neurosurgery patients. But larger studies are needed to make a certain conclusion. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalavagunta, C; Lin, M; Snider, J
Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between maskmore » and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization.« less
Unconsciously triggered conflict adaptation.
van Gaal, Simon; Lamme, Victor A F; Ridderinkhof, K Richard
2010-07-09
In conflict tasks such as the Stroop, the Eriksen flanker or the Simon task, it is generally observed that the detection of conflict in the current trial reduces the impact of conflicting information in the subsequent trial; a phenomenon termed conflict adaptation. This higher-order cognitive control function has been assumed to be restricted to cases where conflict is experienced consciously. In the present experiment we manipulated the awareness of conflict-inducing stimuli in a metacontrast masking paradigm to directly test this assumption. Conflicting response tendencies were elicited either consciously (through primes that were weakly masked) or unconsciously (strongly masked primes). We demonstrate trial-by-trial conflict adaptation effects after conscious as well as unconscious conflict, which could not be explained by direct stimulus/response repetitions. These findings show that unconscious information can have a longer-lasting influence on our behavior than previously thought and further stretch the functional boundaries of unconscious cognition.
Unconsciously Triggered Conflict Adaptation
van Gaal, Simon; Lamme, Victor A. F.; Ridderinkhof, K. Richard
2010-01-01
In conflict tasks such as the Stroop, the Eriksen flanker or the Simon task, it is generally observed that the detection of conflict in the current trial reduces the impact of conflicting information in the subsequent trial; a phenomenon termed conflict adaptation. This higher-order cognitive control function has been assumed to be restricted to cases where conflict is experienced consciously. In the present experiment we manipulated the awareness of conflict-inducing stimuli in a metacontrast masking paradigm to directly test this assumption. Conflicting response tendencies were elicited either consciously (through primes that were weakly masked) or unconsciously (strongly masked primes). We demonstrate trial-by-trial conflict adaptation effects after conscious as well as unconscious conflict, which could not be explained by direct stimulus/response repetitions. These findings show that unconscious information can have a longer-lasting influence on our behavior than previously thought and further stretch the functional boundaries of unconscious cognition. PMID:20634898
Mask etcher data strategy for 45nm and beyond
NASA Astrophysics Data System (ADS)
Lewington, Richard; Ibrahim, Ibrahim M.; Panayil, Sheeba; Kumar, Ajay; Yamartino, John
2006-05-01
Mask Etching for the 45nm technology node and beyond requires a system-level data and diagnostics strategy. This necessity stems from the need to control the performance of the mask etcher to increasingly stringent and diverse requirements of the mask production environment. Increasing mask costs and the capability to acquire and consolidate a wealth of data within the mask etch platform are primary motivators towards harnessing data mines for feedback into the mask etching optimization. There are offline and real-time possibilities and scenarios. Here, we discuss the data architecture, acquisition, and strategies of the Applied Materials Tetra II TM Mask Etch System.
Psychotherapy Augmentation through Preconscious Priming
Borgeat, François; O’Connor, Kieron; Amado, Danielle; St-Pierre-Delorme, Marie-Ève
2013-01-01
Objective: To test the hypothesis that repeated preconscious (masked) priming of personalized positive cognitions could augment cognitive change and facilitate achievement of patients’ goals following a therapy. Methods: Twenty social phobic patients (13 women) completed a 36-weeks study beginning by 12 weeks of group behavioral therapy. After the therapy, they received 6 weeks of preconscious priming and 6 weeks of a control procedure in a randomized cross-over design. The Priming condition involved listening twice daily with a passive attitude to a recording of individualized formulations of appropriate cognitions and attitudes masked by music. The Control condition involved listening to an indistinguishable recording where the formulations had been replaced by random numbers. Changes in social cognitions were measured by the Social Interaction Self Statements Test (SISST). Results: Patients improved following therapy. The Priming procedure was associated with increased positive cognitions and decreased negative cognitions on the SISST while the Control procedure was not. The Priming procedure induced more cognitive change when applied immediately after the group therapy. Conclusion: An effect of priming was observed on social phobia related cognitions in the expected direction. This self administered addition to a therapy could be seen as an augmentation strategy. PMID:23508724
Bakker, Jessie P; Neill, Alister M; Campbell, Angela J
2012-09-01
This single-blinded, randomized, controlled pilot study aimed to investigate whether there is a difference between nasal and oronasal masks in therapeutic continuous positive airway pressure (CPAP) requirement, residual disease, or leak when treating obstructive sleep apnea (OSA) and if differences were related to measures of upper airway size. Patients with severe OSA currently using CPAP at ≥4 h/night with a nasal mask were examined (including Mallampati scale, incisal relationship, and mandibular protrusion) and then randomized to receive auto-positive airway pressure (PAP) or fixed CPAP at a manually titrated pressure for 1 week each at home, with immediate crossover. Within each week, a nasal mask and two oronasal masks were to be used for two or three nights each in random order. Data were downloaded from the device. Twelve patients completed the trial (mean ± SD AHI 59.8 ± 28.6 events/h; CPAP 11.1 ± 3.2 cmH(2)O; BMI 37.7 ± 5.0 kg/m(2)). During auto-PAP, the median 95th percentile pressure delivered with all masks was within 0.5 cmH(2)O (p > 0.05). During CPAP, median residual AHI was 0.61 (IQR = 1.18) for the nasal mask, 1.70 (IQR = 4.04) for oronasal mask 1, and 2.48 (IQR = 3.74) for oronasal mask 2 (p = 0.03). The 95th percentile leak was lowest with the nasal mask during both CPAP and auto-PAP (both p < 0.01). Differences in pressure or residual disease were not related to measures of upper airway shape or body habitus. In obese OSA patients changing from a nasal to oronasal mask increased leak and residual AHI but did not affect the therapeutic pressure requirement. The findings of the current study highlight mask leak as the major difficulty in the use of oronasal masks.
Prebio, Michael; Katz-Papatheophilou, Elfriede; Heindl, Werner; Gelbmann, Herbert; Burghuber, Otto C
2005-02-01
Prone positioning in patients with adult respiratory distress syndrome is a well-known method to improve oxygenation. The aim of our study was to evaluate a new device for prone positioning, the prone-head support system (PHS system), with regard to reduction of cutaneous pressure sores. In a pilot study we randomized 8 patients with ARDS in two groups: 180 degrees standard prone positioning (group without mask) and prone positioning with the PHS system (group with mask). The PHS system consists of a facemask support, which is connected to an adapted air suspension bed. The patients of both groups were intermittently proned for several days. We evaluated the pressure sores on head and neck before turning the patients prone for the first time and after each period of prone positioning. We documented the quantity, the size, the type and the localization of the pressure sores. There was no significant difference in the mean duration of prone positioning (27.1+/-14.7 hours in the group with mask versus 24.5+/-18.7 h in the group without mask). In the group with mask there were 1.5+/-0.8 new pressure sores by each proning, whereas in the group without mask there were 2.37+/-1.6 new pressure sores, which was lower, but not significantly. The overall area of pressure sores (798 mm2 versus 3184 mm2, p=0.004), the area of pressure sores per patient (199.5+/-104.7 mm2 versus 796+/-478 mm2, p=0.03) and the increase of the area of pressure sores per proning (79.8+/-52.0 mm2 versus 398.0+/-214.3 mm2, p=0.004) were significantly lower in the group with mask in comparison to the group without mask. The lips were the most effected localization in both groups. The pressure sores in the group with mask were less severe and showed a homogenous distribution in comparison to the group without mask. Blisters dominated in the group with mask in comparison to erosions, necrosis and ulcers in the group without mask. The PHS system with its face mask is able to reduce the extent and the severity of pressure sores in patients ventilated in prone position. Controlled randomized studies with large study populations seem justified.
NASA Astrophysics Data System (ADS)
Holland, Katharina; van Gils, Carla H.; Wanders, Johanna OP; Mann, Ritse M.; Karssemeijer, Nico
2016-03-01
The sensitivity of mammograms is low for women with dense breasts, since cancers may be masked by dense tissue. In this study, we investigated methods to identify women with density patterns associated with a high masking risk. Risk measures are derived from volumetric breast density maps. We used the last negative screening mammograms of 93 women who subsequently presented with an interval cancer (IC), and, as controls, 930 randomly selected normal screening exams from women without cancer. Volumetric breast density maps were computed from the mammograms, which provide the dense tissue thickness at each location. These were used to compute absolute and percentage glandular tissue volume. We modeled the masking risk for each pixel location using the absolute and percentage dense tissue thickness and we investigated the effect of taking the cancer location probability distribution (CLPD) into account. For each method, we selected cases with the highest masking measure (by thresholding) and computed the fraction of ICs as a function of the fraction of controls selected. The latter can be interpreted as the negative supplemental screening rate (NSSR). Between the models, when incorporating CLPD, no significant differences were found. In general, the methods performed better when CLPD was included. At higher NSSRs some of the investigated masking measures had a significantly higher performance than volumetric breast density. These measures may therefore serve as an alternative to identify women with a high risk for a masked cancer.
Is consciousness necessary for conflict detection and conflict resolution?
Xiang, Ling; Wang, Baoxi; Zhang, Qinglin
2013-06-15
Is conflict control dependent on consciousness? To answer this question, we used high temporal resolution event-related potentials (ERPs) to separate conflict detection from conflict resolution in a masked prime Stroop task. Although behavioral interference effect was present in both the masked and unmasked conditions, the electrophysiological findings revealed more complex patterns. ERP analyses showed that N450 was greater for incongruent trials than for congruent trials and that it was located in the ACC and nearby motor cortex, regardless of whether the primes were masked or unmasked; however, the effects were smaller for the masked than unmasked condition. These results suggest that consciousness of conflict information may not be necessary for detecting conflict, but that it may modulate conflict detection. The analysis of slow potential (SP) amplitude showed that it distinguished incongruent trials from congruent trials, and that this modulation effects was reduced to a greater extent for the masked condition than for the unmasked condition. Moreover, the prefrontal-parietal control network was activated under the unmasked but not under the masked condition. These results suggest that the consciousness of conflict information may be a necessary boundary condition for the subsequent initiation of control operations in the more extended PFC-parietal control network. However, considering that the conflict interference effect was significantly reduced in the masked condition, it may be that, with larger unconscious conflict effects, more extensive cognitive control networks would have been activated. These findings have important implications for theories on the relationship between consciousness and cognitive control. Copyright © 2013 Elsevier B.V. All rights reserved.
Moors, Pieter; Wagemans, Johan; de-Wit, Lee
2014-01-01
Continuous flash suppression (CFS) is a powerful interocular suppression technique, which is often described as an effective means to reliably suppress stimuli from visual awareness. Suppression through CFS has been assumed to depend upon a reduction in (retinotopically specific) neural adaptation caused by the continual updating of the contents of the visual input to one eye. In this study, we started from the observation that suppressing a moving stimulus through CFS appeared to be more effective when using a mask that was actually more prone to retinotopically specific neural adaptation, but in which the properties of the mask were more similar to those of the to-be-suppressed stimulus. In two experiments, we find that using a moving Mondrian mask (i.e., one that includes motion) is more effective in suppressing a moving stimulus than a regular CFS mask. The observed pattern of results cannot be explained by a simple simulation that computes the degree of retinotopically specific neural adaptation over time, suggesting that this kind of neural adaptation does not play a large role in predicting the differences between conditions in this context. We also find some evidence consistent with the idea that the most effective CFS mask is the one that matches the properties (speed) of the suppressed stimulus. These results question the general importance of retinotopically specific neural adaptation in CFS, and potentially help to explain an implicit trend in the literature to adapt one's CFS mask to match one's to-be-suppressed stimuli. Finally, the results should help to guide the methodological development of future research where continuous suppression of moving stimuli is desired.
Effect of SPM-based cleaning POR on EUV mask performance
NASA Astrophysics Data System (ADS)
Choi, Jaehyuck; Lee, Han-shin; Yoon, Jinsang; Shimomura, Takeya; Friz, Alex; Montgomery, Cecilia; Ma, Andy; Goodwin, Frank; Kang, Daehyuk; Chung, Paul; Shin, Inkyun; Cho, H.
2011-11-01
EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. The fact that a pellicle is not used to protect the mask surface in EUV lithography suggests that EUV masks may have to undergo more cleaning cycles during their lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality and patterning performance during 30 cycles of Samsung's EUV mask SPM-based cleaning and 20 cycles of SEMATECH ADT exposure. We have observed that the quality and patterning performance of EUV masks does not significantly change during these processes except mask pattern CD change. To resolve this issue, we have developed an acid-free cleaning POR and substantially improved EUV mask film loss compared to the SPM-based cleaning POR.
Influence of auditory fatigue on masked speech intelligibility
NASA Technical Reports Server (NTRS)
Parker, D. E.; Martens, W. L.; Johnston, P. A.
1980-01-01
Intelligibility of PB word lists embedded in simultaneous masking noise was evaluated before and after fatiguing-noise exposure, which was determined by observing the number of words correctly repeated during a shadowing task. Both the speech signal and the masking noise were filtered to a 2825-3185-Hz band. Masking-noise leves were varied from 0- to 90-dB SL. Fatigue was produced by a 1500-3000-Hz octave band of noise at 115 dB (re 20 micron-Pa) presented continuously for 5 min. The results of three experiments indicated that speed intelligibility was reduced when the speech was presented against a background of silence but that the fatiguing-noise exposure had no effect on intelligibility when the speech was made more intense and embedded in masking noise of 40-90-dB SL. These observations are interpreted by considering the recruitment produced by fatigue and masking noise.
Li, Jiahui; Yu, Qiqing
2016-01-01
Dinse (Biometrics, 38:417-431, 1982) provides a special type of right-censored and masked competing risks data and proposes a non-parametric maximum likelihood estimator (NPMLE) and a pseudo MLE of the joint distribution function [Formula: see text] with such data. However, their asymptotic properties have not been studied so far. Under the extention of either the conditional masking probability (CMP) model or the random partition masking (RPM) model (Yu and Li, J Nonparametr Stat 24:753-764, 2012), we show that (1) Dinse's estimators are consistent if [Formula: see text] takes on finitely many values and each point in the support set of [Formula: see text] can be observed; (2) if the failure time is continuous, the NPMLE is not uniquely determined, and the standard approach (which puts weights only on one element in each observed set) leads to an inconsistent NPMLE; (3) in general, Dinse's estimators are not consistent even under the discrete assumption; (4) we construct a consistent NPMLE. The consistency is given under a new model called dependent masking and right-censoring model. The CMP model and the RPM model are indeed special cases of the new model. We compare our estimator to Dinse's estimators through simulation and real data. Simulation study indicates that the consistent NPMLE is a good approximation to the underlying distribution for moderate sample sizes.
Chang, Jenny Zwei-Chieng; Liu, Pao-Hsin; Chen, Yi-Jane; Yao, Jane Chung-Chen; Chang, Hong-Po; Chang, Chih-Han; Chang, Frank Hsin-Fu
2006-02-01
Face mask therapy is indicated for growing patients who suffer from maxillary retrognathia. Most previous studies used conventional cephalometric analysis to evaluate the effects of face mask treatment. Cephalometric analysis has been shown to be insufficient for complex craniofacial configurations. The purpose of this study was to investigate changes in the craniofacial structure of children with maxillary retrognathism following face mask treatment by means of thin-plate spline analysis. Thirty children with skeletal Class III malocclusions who had been treated with face masks were compared with a group of 30 untreated gender-matched, age-matched, observation period-matched, and craniofacial configuration-matched subjects. Average geometries, scaled to an equivalent size, were generated by means of Procrustes analysis. Thin-plate spline analysis was then performed for localization of the shape changes. Face mask treatment induced a forward displacement of the maxilla, a counterclockwise rotation of the palatal plane, a horizontal compression of the anterior border of the symphysis and the condylar region, and a downward deformation of the menton. The cranial base exhibited a counterclockwise deformation as a whole. We conclude that thin-plate spline analysis is a valuable supplement to conventional cephalometric analysis.
Negative stimulus-response compatibility observed with a briefly displayed image of a hand.
Vainio, Lari
2011-12-01
Manual responses can be primed by viewing an image of a hand. The left-right identity of the viewed hand reflexively facilitates responses of the hand that corresponds to the identity. Previous research also suggests that when the response activation is triggered by an arrow, which is backward-masked and presented briefly, the activation manifests itself in the negative priming effect. The present study showed that response activation, which is produced by an identity of a briefly presented image of a hand, can be similarly associated with a negative priming effect. However, in contrast to the previously reported negative priming effects, the hand stimuli produced negative priming even when the hand was not backward-masked and did not contain task-relevant information. The study supports the view that the automatic inhibition of motor activation triggered by briefly viewed objects is a general and basic functional principle in exogenous motor control processes. Copyright © 2011 Elsevier Inc. All rights reserved.
Risk factors in facial hyperpigmentation in Maghrebian population - a case-control study.
Benchikhi, H; Atide, N; Jroundi, I; Humbert, P; Lakhdar, H
2012-10-01
Triggering factors seem to be multiple in the pathogenesis of facial hyperpigmentation (FH), as dark skin types, pregnancy, sun exposure… The aim of this study was to investigate the risk factors for FH in Maghrebian population. Patients with FH were included in a case-controlled study. Following data were recorded: age, sex, parity, phototype, FH and hormonal-related history, endocrinological features, sunlight exposure, specific cultural behaviours, use of topic corticosteroids and sunscreens. One hundred women (mean age 29.5 ± 13.7 years) were included with 200 age-matched controls. Duration of FH was 32.9 ± 42.2 months. There was a statistically significant relation between FH and hirsutism (P = 0.009), troubles of menstruations (P = 0.008), but not with acne (P = 0.23) and contraceptive oral (P = 0.06) drugs or with history of thyroid disorders (P = 0.13). For cultural factors, there were a statistical significant relation with rubbing by flannel glove (P < 0.05), use of dark soap (P = 0.009) and traditional masks (P < 0.05) but both groups were used to go to hammam. A strong relation was observed between FH and use of topical corticosteroids: 40% in the FH group vs. 5% in the control group (P < 0.05). Both groups used to apply sunscreens: 70% in the FH group and 67% in the control group where as there were no differences in the two groups for sun exposure. No statistical differences were observed regarding to age, phototypes and grade of parity. Our study demonstrated a relation between FH and hyperestrogenemia, rubbing with a friction glove, use of moroccan traditional masks and application of topical steroids. The eviction of all these triggering factors could be an adjuvant recommendation in the assessment of FH. © 2012 Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C
2014-06-01
It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to < 5/h on a titration study. However, it was not previously known whether switching from one CPAP mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, p<0.001). All 14 subjects had a higher residual AHI with the oronasal versus nasal mask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of < 5/h in the laboratory. A higher residual AHI was seen in all patients with the use of an oronasal mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pack, Robert C.; Standiford, Keith; Lukanc, Todd; Ning, Guo Xiang; Verma, Piyush; Batarseh, Fadi; Chua, Gek Soon; Fujimura, Akira; Pang, Linyong
2014-10-01
A methodology is described wherein a calibrated model-based `Virtual' Variable Shaped Beam (VSB) mask writer process simulator is used to accurately verify complex Optical Proximity Correction (OPC) and Inverse Lithography Technology (ILT) mask designs prior to Mask Data Preparation (MDP) and mask fabrication. This type of verification addresses physical effects which occur in mask writing that may impact lithographic printing fidelity and variability. The work described here is motivated by requirements for extreme accuracy and control of variations for today's most demanding IC products. These extreme demands necessitate careful and detailed analysis of all potential sources of uncompensated error or variation and extreme control of these at each stage of the integrated OPC/ MDP/ Mask/ silicon lithography flow. The important potential sources of variation we focus on here originate on the basis of VSB mask writer physics and other errors inherent in the mask writing process. The deposited electron beam dose distribution may be examined in a manner similar to optical lithography aerial image analysis and image edge log-slope analysis. This approach enables one to catch, grade, and mitigate problems early and thus reduce the likelihood for costly long-loop iterations between OPC, MDP, and wafer fabrication flows. It moreover describes how to detect regions of a layout or mask where hotspots may occur or where the robustness to intrinsic variations may be improved by modification to the OPC, choice of mask technology, or by judicious design of VSB shots and dose assignment.
Heebner, John E [Livermore, CA
2009-09-08
In one general embodiment, a method for deflecting an optical signal input into a waveguide is provided. In operation, an optical input signal is propagated through a waveguide. Additionally, an optical control signal is applied to a mask positioned relative to the waveguide such that the application of the optical control signal to the mask is used to influence the optical input signal propagating in the waveguide. Furthermore, the deflected optical input signal output from the waveguide is detected in parallel on an array of detectors. In another general embodiment, a beam deflecting structure is provided for deflecting an optical signal input into a waveguide, the structure comprising at least one wave guiding layer for guiding an optical input signal and at least one masking layer including a pattern configured to influence characteristics of a material of the guiding layer when an optical control signal is passed through the masking layer in a direction of the guiding layer. In another general embodiment, a system is provided including a waveguide, an attenuating mask positioned on the waveguide, and an optical control source positioned to propagate pulsed laser light towards the attenuating mask and the waveguide such that a pattern of the attenuating mask is applied to the waveguide and material properties of at least a portion of the waveguide are influenced.
A Novel Anti-Influenza Copper Oxide Containing Respiratory Face Mask
Borkow, Gadi; Zhou, Steve S.; Page, Tom; Gabbay, Jeffrey
2010-01-01
Background Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. Methodology/Principal Findings We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66±0.51 and 6.17±0.37 log10TCID50 of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (≤0.88 log10TCID50), while 4.67±1.35 log10TCID50 were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were ≤0.97±0.01 log10TCID50 and from the control masks 5.03±0.54 log10TCID50. The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Conclusions/Significance Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks. PMID:20592763
The Effect of a Diving Mask on Intraocular Pressure in a Healthy Population.
Goenadi, Catherina Josephine; Law, David Zhiwei; Lee, Jia Wen; Ong, Ee Lin; Chee, Wai Kitt; Cheng, Jason
2016-01-01
Swimming goggles increase the intraocular pressure (IOP) via the periorbital frame pressure and suction effect. In comparison, diving masks have a larger frame rim and incorporate the nose. The exact effect(s) of diving masks on IOP is unknown. This study evaluates the influence of diving masks on IOP in normal, healthy subjects. Tonometry was performed in both eyes of all subjects with an AVIA(®)Tono-Pen by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. Central corneal thickness (CCT) was also measured in each eye, using a contact pachymeter (OcuScan(®)Alcon). Forty eyes of 20 healthy volunteers (age 29.7 ± 9.3 years; range 21-52) were included. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn had been 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p $1003c; 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = -0.174, p = 0.283) or CCT (r = -0.123, p = 0.445). There was no increase in IOP after the diving mask had been worn. A small but statistically significant decrease in IOP was observed. This study demonstrates that unlike swimming goggles, the strap tension and frame pressure on the periorbital tissue from a diving mask does not increase IOP. Diving masks may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery.
The Effect of a Diving Mask on Intraocular Pressure in a Healthy Population
Goenadi, Catherina Josephine; Law, David Zhiwei; Lee, Jia Wen; Ong, Ee Lin; Chee, Wai Kitt; Cheng, Jason
2016-01-01
Purpose Swimming goggles increase the intraocular pressure (IOP) via the periorbital frame pressure and suction effect. In comparison, diving masks have a larger frame rim and incorporate the nose. The exact effect(s) of diving masks on IOP is unknown. This study evaluates the influence of diving masks on IOP in normal, healthy subjects. Methods Tonometry was performed in both eyes of all subjects with an AVIA®Tono-Pen by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. Central corneal thickness (CCT) was also measured in each eye, using a contact pachymeter (OcuScan®Alcon). Results Forty eyes of 20 healthy volunteers (age 29.7 ± 9.3 years; range 21–52) were included. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn had been 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p $1003c; 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = −0.174, p = 0.283) or CCT (r = −0.123, p = 0.445). Conclusion There was no increase in IOP after the diving mask had been worn. A small but statistically significant decrease in IOP was observed. This study demonstrates that unlike swimming goggles, the strap tension and frame pressure on the periorbital tissue from a diving mask does not increase IOP. Diving masks may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery. PMID:27462262
On the origin of increased sensitivity and mass resolution using silicon masks in MALDI.
Diologent, Laurent; Franck, Julien; Wisztorski, Maxence; Treizebre, Anthony; Focsa, Cristian; Fournier, Isabelle; Ziskind, Michael
2014-02-04
Since its development, MALDI has proved its performance in the analysis of intact biomolecules up to high molecular weights, regardless of their polarity. Sensitivity of MALDI instruments is a key point for breaking the limits of observing biomolecules of lower abundances. Instrumentation is one way to improve sensitivity by increasing ion transmission and using more sensitive detection systems. On the other side, improving MALDI ion production yields would have important outcomes. MALDI ion production is still not well-controlled and, indeed, the amount of ions produced per laser shot with respect to the total volume of desorbed material is very low. This has particular implications for certain applications, such as MALDI MS imaging where laser beam focusing as fine as possible (5-10 μm) is searched in order to reach higher spatial resolution images. However, various studies point out an intrinsic decrease in signal intensity for strong focusing. We have therefore been interested in developing silicon mask systems to decrease an irradiated area by cutting rather than focusing the laser beam and to study the parameters affecting sensitivity using such systems. For this, we systematically examined variation with laser fluence of intensity and spectral resolution in MALDI of standard peptides when using silicon-etched masks of various aperture sizes. These studies demonstrate a simultaneous increase in spectral resolution and signal intensity. Origin of this effect is discussed in the frame of the two-step ionization model. Experimental data in the low fluence range are fitted with an increase of the primary ionization through matrix-silicon edge contact provided by the masks. On the other hand, behavior at higher fluence could be explained by an effect on the secondary ionization via changes in the plume dynamics.
Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production
ERIC Educational Resources Information Center
Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H.
2015-01-01
Purpose: This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method: The authors used noise masking to minimize auditory feedback during…
The organization of the posterior parietal cortex devoted to upper limb actions: An fMRI study
Ferri, Stefania; Rizzolatti, Giacomo
2015-01-01
Abstract The present fMRI study examined whether upper‐limb action classes differing in their motor goal are encoded by different PPC sectors. Action observation was used as a proxy for action execution. Subjects viewed actors performing object‐related (e.g., grasping), skin‐displacing (e.g., rubbing the skin), and interpersonal upper limb actions (e.g., pushing someone). Observation of the three action classes activated a three‐level network including occipito‐temporal, parietal, and premotor cortex. The parietal region common to observing all three action classes was located dorsally to the left intraparietal sulcus (DIPSM/DIPSA border). Regions specific for observing an action class were obtained by combining the interaction between observing action classes and stimulus types with exclusive masking for observing the other classes, while for regions considered preferentially active for a class the interaction was exclusively masked with the regions common to all observed actions. Left putative human anterior intraparietal was specific for observing manipulative actions, and left parietal operculum including putative human SII region, specific for observing skin‐displacing actions. Control experiments demonstrated that this latter activation depended on seeing the skin being moved and not simply on seeing touch. Psychophysiological interactions showed that the two specific parietal regions had similar connectivities. Finally, observing interpersonal actions preferentially activated a dorsal sector of left DIPSA, possibly the homologue of ventral intraparietal coding the impingement of the target person's body into the peripersonal space of the actor. These results support the importance of segregation according to the action class as principle of posterior parietal cortex organization for action observation and by implication for action execution. Hum Brain Mapp 36:3845–3866, 2015. © 2015 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc. PMID:26129732
Del Re, Elisabetta C; Gao, Yi; Eckbo, Ryan; Petryshen, Tracey L; Blokland, Gabriëlla A M; Seidman, Larry J; Konishi, Jun; Goldstein, Jill M; McCarley, Robert W; Shenton, Martha E; Bouix, Sylvain
2016-01-01
Brain masking of MRI images separates brain from surrounding tissue and its accuracy is important for further imaging analyses. We implemented a new brain masking technique based on multi-atlas brain segmentation (MABS) and compared MABS to masks generated using FreeSurfer (FS; version 5.3), Brain Extraction Tool (BET), and Brainwash, using manually defined masks (MM) as the gold standard. We further determined the effect of different masking techniques on cortical and subcortical volumes generated by FreeSurfer. Images were acquired on a 3-Tesla MR Echospeed system General Electric scanner on five control and five schizophrenia subjects matched on age, sex, and IQ. Automated masks were generated from MABS, FS, BET, and Brainwash, and compared to MM using these metrics: a) volume difference from MM; b) Dice coefficients; and c) intraclass correlation coefficients. Mean volume difference between MM and MABS masks was significantly less than the difference between MM and FS or BET masks. Dice coefficient between MM and MABS was significantly higher than Dice coefficients between MM and FS, BET, or Brainwash. For subcortical and left cortical regions, MABS volumes were closer to MM volumes than were BET or FS volumes. For right cortical regions, MABS volumes were closer to MM volumes than were BET volumes. Brain masks generated using FreeSurfer, BET, and Brainwash are rapidly obtained, but are less accurate than manually defined masks. Masks generated using MABS, in contrast, resemble more closely the gold standard of manual masking, thereby offering a rapid and viable alternative. Copyright © 2015 by the American Society of Neuroimaging.
NASA Astrophysics Data System (ADS)
Kamikubo, Takashi; Ohnishi, Takayuki; Hara, Shigehiro; Anze, Hirohito; Hattori, Yoshiaki; Tamamushi, Shuichi; Bai, Shufeng; Wang, Jen-Shiang; Howell, Rafael; Chen, George; Li, Jiangwei; Tao, Jun; Wiley, Jim; Kurosawa, Terunobu; Saito, Yasuko; Takigawa, Tadahiro
2010-09-01
In electron beam writing on EUV mask, it has been reported that CD linearity does not show simple signatures as observed with conventional COG (Cr on Glass) masks because they are caused by scattered electrons form EUV mask itself which comprises stacked heavy metals and thick multi-layers. To resolve this issue, Mask Process Correction (MPC) will be ideally applicable. Every pattern is reshaped in MPC. Therefore, the number of shots would not increase and writing time will be kept within reasonable range. In this paper, MPC is extended to modeling for correction of CD linearity errors on EUV mask. And its effectiveness is verified with simulations and experiments through actual writing test.
Eddy, Marianna D.; Holcomb, Phillip J.
2010-01-01
The current study used event-related potentials (ERPs) and masked repetition priming to examine the time-course of picture processing. We manipulated the stimulus-onset asynchrony (110 ms, 230 ms, 350 ms, 470 ms) between repeated and unrepeated prime-target pairs while holding the prime duration constant (50 ms) (Experiment 1) as well as the prime duration (30 ms, 50 ms, 70 ms, 90 ms) (Experiment 2) with a constant SOA of 110 ms in a masked repetition priming paradigm with pictures. The aim of this study was to further elucidate the mechanisms underlying previously observed ERP components in masked priming with pictures. We found both the N/P190 and N400 are modulated by changes in prime duration and SOA, however, it appears that longer prime exposure rather than a longer SOA leads to more in-depth processing as indexed by larger N400 effects. PMID:20403342
Individual differences in metacontrast masking regarding sensitivity and response bias.
Albrecht, Thorsten; Mattler, Uwe
2012-09-01
In metacontrast masking target visibility is modulated by the time until a masking stimulus appears. The effect of this temporal delay differs across participants in such a way that individual human observers' performance shows distinguishable types of masking functions which remain largely unchanged for months. Here we examined whether individual differences in masking functions depend on different response criteria in addition to differences in discrimination sensitivity. To this end we reanalyzed previously published data and conducted a new experiment for further data analyses. Our analyses demonstrate that a distinction of masking functions based on the type of masking stimulus is superior to a distinction based on the target-mask congruency. Individually different masking functions are based on individual differences in discrimination sensitivities and in response criteria. Results suggest that individual differences in metacontrast masking result from individually different criterion contents. Copyright © 2012 Elsevier Inc. All rights reserved.
What's in a mask? Information masking with forward and backward visual masks.
Davis, Chris; Kim, Jeesun
2011-10-01
Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.
Attentional capture by masked colour singletons.
Ansorge, Ulrich; Horstmann, Gernot; Worschech, Franziska
2010-09-15
We tested under which conditions a colour singleton of which an observer is unaware captures attention. To prevent visual awareness of the colour singleton, we used backward masking. We find that a masked colour singleton cue captures attention if it matches the observer's goal to search for target colours but not if it is task-irrelevant. This is also reflected in event-related potentials to the visible target: the masked goal-matching cue elicits an attentional potential (N2pc) in a target search task. By contrast, a non-matching but equally strong masked colour singleton cue failed to elicit a capture effect and an N2pc. Results are discussed with regard to currently pertaining conceptions of attentional capture by colour singletons. Copyright 2010 Elsevier Ltd. All rights reserved.
Detection of visual events along the apparent motion trace in patients with paranoid schizophrenia.
Sanders, Lia Lira Olivier; Muckli, Lars; de Millas, Walter; Lautenschlager, Marion; Heinz, Andreas; Kathmann, Norbert; Sterzer, Philipp
2012-07-30
Dysfunctional prediction in sensory processing has been suggested as a possible causal mechanism in the development of delusions in patients with schizophrenia. Previous studies in healthy subjects have shown that while the perception of apparent motion can mask visual events along the illusory motion trace, such motion masking is reduced when events are spatio-temporally compatible with the illusion, and, therefore, predictable. Here we tested the hypothesis that this specific detection advantage for predictable target stimuli on the apparent motion trace is reduced in patients with paranoid schizophrenia. Our data show that, although target detection along the illusory motion trace is generally impaired, both patients and healthy control participants detect predictable targets more often than unpredictable targets. Patients had a stronger motion masking effect when compared to controls. However, patients showed the same advantage in the detection of predictable targets as healthy control subjects. Our findings reveal stronger motion masking but intact prediction of visual events along the apparent motion trace in patients with paranoid schizophrenia and suggest that the sensory prediction mechanism underlying apparent motion is not impaired in paranoid schizophrenia. Copyright © 2012. Published by Elsevier Ireland Ltd.
Trevisanuto, Daniele; Cavallin, Francesco; Nguyen, Loi Ngoc; Nguyen, Tien Viet; Tran, Linh Dieu; Tran, Chien Dinh; Doglioni, Nicoletta; Micaglio, Massimo; Moccia, Luciano
2015-08-01
To assess the effectiveness of supreme laryngeal mask airway (SLMA) over face mask ventilation for preventing need for endotracheal intubation at birth. We report a prospective, randomized, parallel 1:1, unblinded, controlled trial. After a short-term educational intervention on SLMA use, infants ≥34-week gestation and/or expected birth weight ≥1500 g requiring positive pressure ventilation (PPV) at birth were randomized to resuscitation by SLMA or face mask. The primary outcome was the success rate of the resuscitation devices (SLMA or face mask) defined as the achievement of an effective PPV preventing the need for endotracheal intubation. We enrolled 142 patients (71 in SLMA and 71 in face mask group, respectively). Successful resuscitation rate was significantly higher with the SLMA compared with face mask ventilation (91.5% vs 78.9%; P = .03). Apgar score at 5 minutes was significantly higher in SLMA than in face mask group (P = .02). Neonatal intensive care unit admission rate was significantly lower in SLMA than in face mask group (P = .02). No complications related to the procedure occurred. In newborns with gestational age ≥34 weeks and/or expected birth weight ≥1500 g needing PPV at birth, the SLMA is more effective than face mask to prevent endotracheal intubation. The SLMA is effective in clinical practice after a short-term educational intervention. Registered with ClinicalTrials.gov: NCT01963936. Copyright © 2015 Elsevier Inc. All rights reserved.
Progress on EUV mask fabrication for 32-nm technology node and beyond
NASA Astrophysics Data System (ADS)
Zhang, Guojing; Yan, Pei-Yang; Liang, Ted; Park, Seh-jin; Sanchez, Peter; Shu, Emily Y.; Ultanir, Erdem A.; Henrichs, Sven; Stivers, Alan; Vandentop, Gilroy; Lieberman, Barry; Qu, Ping
2007-05-01
Extreme ultraviolet lithography (EUVL) tool development achieved a big milestone last year as two full-field Alpha Demo Tools (ADT) were shipped to customers by ASML. In the future horizon, a full field "EUV1" exposure tool from Nikon will be available by the end of 20071 and the pre-production EUV exposure tools from ASML are targeted for 20092. It is essential that high quality EUVL masks can be made and delivered to the EUVL tool users to support the technology development. In the past year, we have demonstrated mask fabrication with low stress absorber deposition and good etch process control yielding a vertical etch profile and a mask CD control of 5.7 nm for 32 nm (1x) space and 7.4 nm for 32 nm (1x) lines. Mask pattern resolution of 15 nm (1x) dense lines was achieved. Full field reflective mask die-to-die inspection at a 125nm pixel size was demonstrated after low defect multilayer blanks became available. In this paper, we will present details of the Intel EUVL Mask Pilot Line progress in EUVL mask defect reduction, pattern CD performance, program defect mask design and inspection, in-house absorber film development and its performance, and EUVL metrology tool development. We will demonstrate an overall improvement in EUV mask manufacturing readiness due to our Pilot Line activities.
NASA Technical Reports Server (NTRS)
Cason, W. E. I.; Baucom, R. M.; Evans, R. C.
1982-01-01
Lightweight face mask originally developed to protect epileptic patients during seizures could have many other medical and nonmedical applications such as muscular distrophy patients, football linesmen and riot-control police. Masks are extremely lightweight, the lightest of the configurations weighing only 136 grams.
Use of face masks by non-scrubbed operating room staff: a randomized controlled trial.
Webster, Joan; Croger, Sarah; Lister, Carolyn; Doidge, Michelle; Terry, Michael J; Jones, Ian
2010-03-01
Ambiguity remains about the effectiveness of wearing surgical face masks. The purpose of this study was to assess the impact on surgical site infections (SSIs) when non-scrubbed operating room staff did not wear surgical face masks. Eight hundred twenty-seven participants undergoing elective or emergency obstetric, gynecological, general, orthopaedic, breast or urological surgery in an Australian tertiary hospital were enrolled. Complete follow-up data were available for 811 patients (98.1%). Operating room lists were randomly allocated to a 'Mask group' (all non-scrubbed staff wore a mask) or 'No Mask group' (none of the non-scrubbed staff wore masks). The primary end point, SSI was identified using in-patient surveillance; post discharge follow-up and chart reviews. The patient was followed for up to six weeks. Overall, 83 (10.2%) surgical site infections were recorded; 46/401 (11.5%) in the Masked group and 37/410 (9.0%) in the No Mask group; odds ratio (OR) 0.77 (95% confidence interval (CI) 0.49 to 1.21), p = 0.151. Independent risk factors for surgical site infection included: any pre-operative stay (adjusted odds ratio [aOR], 0.43 (95% CI, 0.20; 0.95), high BMI aOR, 0.38 (95% CI, 0.17; 0.87), and any previous surgical site infection aOR, 0.40 (95% CI, 0.17; 0.89). Surgical site infection rates did not increase when non-scrubbed operating room personnel did not wear a face mask.
Effect of Otitis Media with Effusion on Comodulation Masking Release in Children.
ERIC Educational Resources Information Center
Hall, Joseph W.; Grose, John H.
1994-01-01
This study investigated comodulation masking release (CMR) in 42 children (ages 5 to 10) with a history of otitis media with effusion (OME) and 19 control children with no history of ear disease. Results indicated that monotic CMRs were reduced in children with hearing loss due to OME and these CMRs remained abnormally small for several months.…
Shikama, Maiko; Nakagami, Gojiro; Noguchi, Hiroshi; Mori, Taketoshi; Sanada, Hiromi
2018-05-22
Pressure ulcers related to oronasal masks used with noninvasive ventilation (NIV), along with patient discomfort, occur due to improper fit of the mask. We developed a personalized fitting device using a 3-dimensional (3D) scanning solution to prevent the formation of NIV mask-related pressure ulcers. This study aimed to evaluate the effectiveness of the proposed personalized fitting device. We conducted a randomized crossover experimental study of 20 healthy participants to study the use of this personalized fitting device between the face and an NIV mask designed with 3D solutions. The fitting device was not used under the NIV mask for the control. The outcome measures were the presence of blanchable erythema, standardized redness intensity, discomfort level, and contact pressure. The incidence of blanchable erythema and standardized redness intensity values were significantly lower for subjects who used the fitting device when worn for 30 min ( P < .001). The discomfort levels at the forehead, nasal bridge, and both cheeks, as well as leakage, were significantly reduced as well ( P = .008, P < .001, P = .001, P = .002, P = .001, P = .02, P < .001, P < .001, P < .001). Contact pressure at the nasal bridge, where pressure ulcers most frequently develop, was significantly decreased with the fitting device ( P < .001). Personalized fitting devices that incorporate 3D scanning solutions may contribute to the prevention of NIV mask-related pressure ulcers and the reduction of discomfort. Copyright © 2018 by Daedalus Enterprises.
Brandt, Christian; Rabenau, Holger F.; Wicker, Sabine
2010-01-01
Please cite this paper as: Brandt et al. (2010) Attitudes of influenza‐vaccinated health care workers toward masks to prevent nosocomial transmission of influenza. . Influenza and Other Respiratory Viruses 5(1), 61–66. Background Influenza viruses are highly contagious. Health care workers (HCWs) are at risk of occupational exposure to influenza and may transmit the infection to their patients and coworkers. Objectives The aim of the study was to characterize the attitudes of HCWs regarding the use of surgical masks to prevent nosocomial influenza transmission. Furthermore, we assessed the informational needs of HCWs with regard to infection control measures. Methods A survey was conducted among HCWs, using an anonymous questionnaire, at a German University Hospital during an influenza vaccination campaign. Results Overall, 40·5% of the HCWs were vaccinated against seasonal influenza, and 35·2% were vaccinated against Influenza A/H1N1 (“swine flu”). In total, 1445 vaccinees completed the anonymous questionnaire. Of all respondents, 70·5% stated that the infection control recommendation “wearing a surgical” mask was appropriate to avoid influenza transmission. The percentage of HCWs who would like to have had more information about the infection control measures was 67·5%. Conclusions Appropriate interventions ought to be taken to reduce the risk of exposure to influenza viruses among HCWs. Adherence to recommendations for the use of masks among HCWs needs to be evaluated. Further work is required to highlight the informational needs of HCWs to gain an appreciation of infection control measures. PMID:21138542
Less is More: Neural Activity During Very Brief and Clearly Visible Exposure to Phobic Stimuli
Siegel, Paul; Warren, Richard; Wang, Zhishun; Yang, Jie; Cohen, Don; Anderson, Jason F.; Murray, Lilly; Peterson, Bradley S.
2017-01-01
Research on automatic processes in emotion has focused almost exclusively on the provocation of fear responses. We have shown, in contrast, that the repeated presentation of masked feared images reduces avoidance of a live tarantula by spider-phobic participants. We investigated the neural basis for these adaptive effects of masked exposure. We identified 21 spider-phobic and 21 control participants using a psychiatric interview, fear questionnaire, and approach behavior towards a live tarantula. They received each of three conditions: (1) very brief exposure (VBE) to masked images of spiders; (2) clearly visible exposure (CVE) to spiders; and (3) masked images of flowers (control). Only VBE to masked spiders generated neural activity more strongly in phobic than in control participants, within subcortical fear, attention, higher-order language, and vision systems. Counter-intuitively, CVE to the same spiders generated stronger neural activity in control rather than phobic participants within these and other systems. VBE activated regions that support fear processing in phobic participants without causing them to experience fear consciously. CVE, by contrast, deactivated regions supporting fear regulation and caused phobic participants to experience fear. Activations by CVE to spiders correlated with fear ratings - explicit fear. Activations by VBE to masked spiders correlated with color-naming interference of spider words – implicit fear. These multiple dissociations between the effects of VBE and CVE to spiders suggest that limiting awareness of exposure to phobic stimuli through visual masking paradoxically facilitates their processing, while simultaneously minimizing the experience of fear. PMID:28165171
NASA Technical Reports Server (NTRS)
Matus, Carlos V.
1989-01-01
Alignment viewed through microscope. Alignment jig positions shadow mask on charge-coupled device (CCD) so metal film deposited on it precisely. Allows CCD package to be inserted and removed without disturbing alignment of mask. Holds CCD packages securely and isolates it electrostatically while providing electrical contact to each of its pins. When alignment jig assembled with CCD, used to move mask under micrometer control.
Dharmadhikari, Ashwin S; Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A; van der Walt, Martie; Nardell, Edward A
2012-05-15
Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68-85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31-51%), representing a 56% (95% CI, 33-70.5%) decreased risk of TB transmission when patients used masks. Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients.
Liu, Jing; Chen, Chaoyang; Yang, Guangsong; Chen, Yushan; Yang, Cheng-Fu
2017-01-01
The nanosphere lithography (NSL) method can be developed to deposit the Au-Ag triangle hexagonal nanoparticle arrays for the generation of localized surface plasmon resonance. Previously, we have found that the parameters used to form the NSL masks and the physical methods required to deposit the Au-Ag thin films had large effects on the geometry properties of the nanoparticle arrays. Considering this, the different parameters used to grow the Au-Ag triangle hexagonal nanoparticle arrays were investigated. A single-layer NSL mask was formed by using self-assembly nano-scale polystyrene (PS) nanospheres with an average radius of 265 nm. At first, the concentration of the nano-scale PS nanospheres in the solution was set at 6 wt %. Two coating methods, drop-coating and spin-coating, were used to coat the nano-scale PS nanospheres as a single-layer NSL mask. From the observations of scanning electronic microscopy (SEM), we found that the matrixes of the PS nanosphere masks fabricated by using the drop-coating method were more uniform and exhibited a smaller gap than those fabricated by the spin-coating method. Next, the drop-coating method was used to form the single-layer NSL mask and the concentration of nano-scale PS nanospheres in a solution that was changed from 4 to 10 wt %, for further study. The SEM images showed that when the concentrations of PS nanospheres in the solution were 6 and 8 wt %, the matrixes of the PS nanosphere masks were more uniform than those of 4 and 10 wt %. The effects of the one-side lifting angle of substrates and the vaporization temperature for the solvent of one-layer self-assembly PS nanosphere thin films, were also investigated. Finally, the concentration of the nano-scale PS nanospheres in the solution was set at 8 wt % to form the PS nanosphere masks by the drop-coating method. Three different physical deposition methods, including thermal evaporation, radio-frequency magnetron sputtering, and e-gun deposition, were used to deposit the Au-Ag triangle hexagonal periodic nanoparticle arrays. The SEM images showed that as the single-layer PS nanosphere mask was well controlled, the thermal evaporation could deposit the Au-Ag triangle hexagonal nanoparticle arrays with a higher quality than the other two methods. PMID:28772741
Liu, Jing; Chen, Chaoyang; Yang, Guangsong; Chen, Yushan; Yang, Cheng-Fu
2017-04-03
The nanosphere lithography (NSL) method can be developed to deposit the Au-Ag triangle hexagonal nanoparticle arrays for the generation of localized surface plasmon resonance. Previously, we have found that the parameters used to form the NSL masks and the physical methods required to deposit the Au-Ag thin films had large effects on the geometry properties of the nanoparticle arrays. Considering this, the different parameters used to grow the Au-Ag triangle hexagonal nanoparticle arrays were investigated. A single-layer NSL mask was formed by using self-assembly nano-scale polystyrene (PS) nanospheres with an average radius of 265 nm. At first, the concentration of the nano-scale PS nanospheres in the solution was set at 6 wt %. Two coating methods, drop-coating and spin-coating, were used to coat the nano-scale PS nanospheres as a single-layer NSL mask. From the observations of scanning electronic microscopy (SEM), we found that the matrixes of the PS nanosphere masks fabricated by using the drop-coating method were more uniform and exhibited a smaller gap than those fabricated by the spin-coating method. Next, the drop-coating method was used to form the single-layer NSL mask and the concentration of nano-scale PS nanospheres in a solution that was changed from 4 to 10 wt %, for further study. The SEM images showed that when the concentrations of PS nanospheres in the solution were 6 and 8 wt %, the matrixes of the PS nanosphere masks were more uniform than those of 4 and 10 wt %. The effects of the one-side lifting angle of substrates and the vaporization temperature for the solvent of one-layer self-assembly PS nanosphere thin films, were also investigated. Finally, the concentration of the nano-scale PS nanospheres in the solution was set at 8 wt % to form the PS nanosphere masks by the drop-coating method. Three different physical deposition methods, including thermal evaporation, radio-frequency magnetron sputtering, and e-gun deposition, were used to deposit the Au-Ag triangle hexagonal periodic nanoparticle arrays. The SEM images showed that as the single-layer PS nanosphere mask was well controlled, the thermal evaporation could deposit the Au-Ag triangle hexagonal nanoparticle arrays with a higher quality than the other two methods.
Significance of auditory and kinesthetic feedback to singers' pitch control.
Mürbe, Dirk; Pabst, Friedemann; Hofmann, Gert; Sundberg, Johan
2002-03-01
An accurate control of fundamental frequency (F0) is required from singers. This control relies on auditory and kinesthetic feedback. However, a loud accompaniment may mask the auditory feedback, leaving the singers to rely on kinesthetic feedback. The object of the present study was to estimate the significance of auditory and kinesthetic feedback to pitch control in 28 students beginning a professional solo singing education. The singers sang an ascending and descending triad pattern covering their entire pitch range with and without masking noise in legato and staccato and in a slow and a fast tempo. F0 was measured by means of a computer program. The interval sizes between adjacent tones were determined and their departures from equally tempered tuning were calculated. The deviations from this tuning were used as a measure of the accuracy of intonation. Statistical analysis showed a significant effect of masking that amounted to a mean impairment of pitch accuracy by 14 cent across all subjects. Furthermore, significant effects were found of tempo as well as of the staccato/legato conditions. The results indicate that auditory feedback contributes significantly to singers' control of pitch.
Lemyze, Malcolm; Mallat, Jihad; Nigeon, Olivier; Barrailler, Stéphanie; Pepy, Florent; Gasan, Gaëlle; Vangrunderbeeck, Nicolas; Grosset, Philippe; Tronchon, Laurent; Thevenin, Didier
2013-02-01
To evaluate the impact of switching to total face mask in cases where face mask-delivered noninvasive mechanical ventilation has already failed in do-not-intubate patients in acute respiratory failure. Prospective observational study in an ICU and a respiratory stepdown unit over a 12-month study period. Switching to total face mask, which covers the entire face, when noninvasive mechanical ventilation using facial mask (oronasal mask) failed to reverse acute respiratory failure. Seventy-four patients with a do-not-intubate order and treated by noninvasive mechanical ventilation for acute respiratory failure. Failure of face mask-delivered noninvasive mechanical ventilation was associated with a three-fold increase in in-hospital mortality (36% vs. 10.5%; p = 0.009). Nevertheless, 23 out of 36 patients (64%) in whom face mask-delivered noninvasive mechanical ventilation failed to reverse acute respiratory failure and, therefore, switched to total face mask survived hospital discharge. Reasons for switching from facial mask to total face mask included refractory hypercapnic acute respiratory failure (n = 24, 66.7%), painful skin breakdown or facial mask intolerance (n = 11, 30%), and refractory hypoxemia (n = 1, 2.7%). In the 24 patients switched from facial mask to total face mask because of refractory hypercapnia, encephalopathy score (3 [3-4] vs. 2 [2-3]; p < 0.0001), PaCO2 (87 ± 25 mm Hg vs. 70 ± 17 mm Hg; p < 0.0001), and pH (7.24 ± 0.1 vs. 7.32 ± 0.09; p < 0.0001) significantly improved after 2 hrs of total face mask-delivered noninvasive ventilation. Patients switched early to total face mask (in the first 12 hrs) developed less pressure sores (n = 5, 24% vs. n = 13, 87%; p = 0.0002), despite greater length of noninvasive mechanical ventilation within the first 48 hrs (44 hrs vs. 34 hrs; p = 0.05) and less protective dressings (n = 2, 9.5% vs. n = 8, 53.3%; p = 0.007). The optimal cutoff value for face mask-delivered noninvasive mechanical ventilation duration in predicting facial pressure sores was 11 hrs (area under the receiver operating characteristic curve, 0.86 ± 0.04; 95% confidence interval 0.76-0.93; p < 0.0001; sensitivity, 84%; specificity, 71%). In patients in hypercapnic acute respiratory failure, for whom escalation to intubation is deemed inappropriate, switching to total face mask can be proposed as a last resort therapy when face mask-delivered noninvasive mechanical ventilation has already failed to reverse acute respiratory failure. This strategy is particularly adapted to provide prolonged periods of continuous noninvasive mechanical ventilation while preventing facial pressure sores.
Psychometric functions for informational masking
NASA Astrophysics Data System (ADS)
Lutfi, Robert A.; Kistler, Doris J.; Callahan, Michael R.; Wightman, Frederic L.
2003-12-01
The term informational masking has traditionally been used to refer to elevations in signal threshold resulting from masker uncertainty. In the present study, the method of constant stimuli was used to obtain complete psychometric functions (PFs) from 44 normal-hearing listeners in conditions known to produce varying amounts of informational masking. The listener's task was to detect a pure-tone signal in the presence of a broadband noise masker (low masker uncertainty) and in the presence of multitone maskers with frequencies and amplitudes that varied at random from one presentation to the next (high masker uncertainty). Relative to the broadband noise condition, significant reductions were observed in both the slope and the upper asymptote of the PF for multitone maskers producing large amounts of informational masking. Slope was affected more for some listeners and conditions while asymptote was affected more for others; consequently, neither parameter alone was highly predictive of individual thresholds or the amount of informational masking. Mean slopes and asymptotes varied nonmonotonically with the number of masker components in a manner similar to mean thresholds, particularly when the estimated effect of energetic masking on thresholds was subtracted out. As in past studies, the threshold data were well described by a model in which trial-by-trial judgments are based on a weighted sum of levels in dB at the output of independent auditory filters. The psychometric data, however, complicated the model's interpretation in two ways: First, they suggested that, depending on the listener and condition, the weights can either reflect a fixed influence of masker components on each trial or the effect of occasionally mistaking a masker component for the signal from trial to trial. Second, they indicated that in either case the variance of the underlying decision variable as estimated from PF slope is not by itself great enough to account for the observed changes in informational masking.
López-Alcalde, Jesús; Mateos-Mazón, Marta; Guevara, Marcela; Conterno, Lucieni O; Solà, Ivan; Cabir Nunes, Sheila; Bonfill Cosp, Xavier
2015-07-16
Meticillin-resistant Staphylococcus aureus (MRSA; also known as methicillin-resistant S aureus) is a common hospital-acquired pathogen that increases morbidity, mortality, and healthcare costs. Its control continues to be an unresolved issue in many hospitals worldwide. The evidence base for the effects of the use of gloves, gowns or masks as control measures for MRSA is unclear. To assess the effectiveness of wearing gloves, a gown or a mask when contact is anticipated with a hospitalised patient colonised or infected with MRSA, or with the patient's immediate environment. We searched the Specialised Registers of three Cochrane Groups (Wounds Group on 5 June 2015; Effective Practice and Organisation of Care (EPOC) Group on 9 July 2013; and Infectious Diseases Group on 5 January 2009); CENTRAL (The Cochrane Library 2015, Issue 6); DARE, HTA, NHS EED, and the Methodology Register (The Cochrane Library 2015, Issue 6); MEDLINE and MEDLINE In-Process & Other Non-Indexed Citations (1946 to June week 1 2015); EMBASE (1974 to 4 June 2015); Web of Science (WOS) Core Collection (from inception to 7 June 2015); CINAHL (1982 to 5 June 2015); British Nursing Index (1985 to 6 July 2010); and ProQuest Dissertations & Theses Database (1639 to 11 June 2015). We also searched three trials registers (on 6 June 2015), references list of articles, and conference proceedings. We finally contacted relevant individuals for additional studies. Studies assessing the effects on MRSA transmission of the use of gloves, gowns or masks by any person in the hospital setting when contact is anticipated with a hospitalised patient colonised or infected with MRSA, or with the patient's immediate environment. We did not assess adverse effects or economic issues associated with these interventions.We considered any comparator to be eligible. With regard to study design, only randomised controlled trials (clustered or not) and the following non-randomised experimental studies were eligible: quasi-randomised controlled trials (clustered or not), non-randomised controlled trials (clustered or not), controlled before-and-after studies, controlled cohort before-after studies, interrupted time series studies (controlled or not), and repeated measures studies. We did not exclude any study on the basis of language or date of publication. Two review authors independently decided on eligibility of the studies. Had any study having been included, two review authors would have extracted data (at least for outcome data) and assessed the risk of bias independently. We would have followed the standard methodological procedures suggested by Cochrane and the Cochrane EPOC Group for assessing risk of bias and analysing the data. We identified no eligible studies for this review, either completed or ongoing. We found no studies assessing the effects of wearing gloves, gowns or masks for contact with MRSA hospitalised patients, or with their immediate environment, on the transmission of MRSA to patients, hospital staff, patients' caregivers or visitors. This absence of evidence should not be interpreted as evidence of no effect for these interventions. The effects of gloves, gowns and masks in these circumstances have yet to be determined by rigorous experimental studies, such as cluster-randomised trials involving multiple wards or hospitals, or interrupted time series studies.
Marissen, Marlies A E; Brouwer, Marlies E; Hiemstra, Annemarie M F; Deen, Mathijs L; Franken, Ingmar H A
2016-08-30
The mask model of narcissism states that the narcissistic traits of patients with NPD are the result of a compensatory reaction to underlying ego fragility. This model assumes that high explicit self-esteem masks low implicit self-esteem. However, research on narcissism has predominantly focused on non-clinical participants and data derived from patients diagnosed with Narcissistic Personality Disorder (NPD) remain scarce. Therefore, the goal of the present study was to test the mask model hypothesis of narcissism among patients with NPD. Male patients with NPD were compared to patients with other PD's and healthy participants on implicit and explicit self-esteem. NPD patients did not differ in levels of explicit and implicit self-esteem compared to both the psychiatric and the healthy control group. Overall, the current study found no evidence in support of the mask model of narcissism among a clinical group. This implicates that it might not be relevant for clinicians to focus treatment of NPD on an underlying negative self-esteem. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Compliance with the Use of Medical and Cloth Masks Among Healthcare Workers in Vietnam.
Chughtai, Abrar Ahmad; Seale, Holly; Dung, Tham Chi; Hayen, Andrew; Rahman, Bayzidur; Raina MacIntyre, C
2016-06-01
Masks are often worn in healthcare settings to prevent the spread of infection from healthcare workers (HCWs) to patients. Masks are also used to protect the employee from patient-generated infectious organisms but poor compliance can reduce efficacy. The aim of this study was to examine the factors influencing compliance with the use of medical and cloth masks amongst hospital HCWs. HCWs compliance with the use of medical and cloth masks was measured over a 4-week period in a randomized controlled trial in Vietnam. HCWs were instructed to record their daily activities in diary cards. Demographic, clinical, and diary card data were used to determine the predictors of compliance and the relationship of compliance with infection outcomes. Compliance rates for both medical and cloth masks decreased during the 4 weeks: medical mask use decreased from 77 to 68% (P < 0.001) and cloth masks from 78 to 69% (P < 0.001). The presence of adverse events (adjusted RR 0.90, 95% CI 0.85-0.95), and performing aerosol-generating procedures (adjusted RR 0.78, 95% CI 0.73-0.82) were negatively associated with compliance, while contact with febrile respiratory illness patients was positively associated (adjusted RR 1.14, 95% CI 1.07-1.20). Being compliant with medical or cloth masks use (average use ≥70% of working time) was not associated with clinical respiratory illness, influenza-like illness, and laboratory-confirmed viral infection. Understanding the factors that affect compliance is important for the occupational health and safety of HCWs. New strategies and tools should be developed to increase compliance of HCWs. The presence of adverse events such as discomfort and breathing problems may be the main reasons for the low compliance with mask use and further studies should be conducted to improve the design/material of masks to improve comfort for the wearer. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Roberts, Larry E; Bosnyak, Daniel J; Bruce, Ian C; Gander, Phillip E; Paul, Brandon T
2015-09-01
It has been proposed that tinnitus is generated by aberrant neural activity that develops among neurons in tonotopic of regions of primary auditory cortex (A1) affected by hearing loss, which is also the frequency region where tinnitus percepts localize (Eggermont and Roberts 2004; Roberts et al., 2010, 2013). These models suggest (1) that differences between tinnitus and control groups of similar age and audiometric function should depend on whether A1 is probed in tinnitus frequency region (TFR) or below it, and (2) that brain responses evoked from A1 should track changes in the tinnitus percept when residual inhibition (RI) is induced by forward masking. We tested these predictions by measuring (128-channel EEG) the sound-evoked 40-Hz auditory steady-state response (ASSR) known to localize tonotopically to neural sources in A1. For comparison the N1 transient response localizing to distributed neural sources in nonprimary cortex (A2) was also studied. When tested under baseline conditions where tinnitus subjects would have heard their tinnitus, ASSR responses were larger in a tinnitus group than in controls when evoked by 500 Hz probes while the reverse was true for tinnitus and control groups tested with 5 kHz probes, confirming frequency-dependent group differences in this measure. On subsequent trials where RI was induced by masking (narrow band noise centered at 5 kHz), ASSR amplitude increased in the tinnitus group probed at 5 kHz but not in the tinnitus group probed at 500 Hz. When collapsed into a single sample tinnitus subjects reporting comparatively greater RI depth and duration showed comparatively larger ASSR increases after masking regardless of probe frequency. Effects of masking on ASSR amplitude in the control groups were completely reversed from those in the tinnitus groups, with no change seen to 5 kHz probes but ASSR increases to 500 Hz probes even though the masking sound contained no energy at 500 Hz (an "off-frequency" masking effect). In contrast to these findings for the ASSR, N1 amplitude was larger in tinnitus than control groups at both probe frequencies under baseline conditions, decreased after masking in all conditions, and did not relate to RI. These results suggest that aberrant neural activity occurring in the TFR of A1 underlies tinnitus and its modulation during RI. They indicate further that while neural changes occur in A2 in tinnitus, these changes do not reflect the tinnitus percept. Models for tinnitus and forward masking are described that integrate these findings within a common framework. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Masked priming effects are modulated by expertise in the script.
Perea, Manuel; Abu Mallouh, Reem; Garcı A-Orza, Javier; Carreiras, Manuel
2011-05-01
In a recent study using a masked priming same-different matching task, Garcı´a-Orza, Perea, and Munoz (2010) found a transposition priming effect for letter strings, digit strings, and symbol strings, but not for strings of pseudoletters (i.e., EPRI-ERPI produced similar response times to the control pair EDBI-ERPI). They argued that the mechanism responsible for position coding in masked priming is not operative with those "objects" whose identity cannot be attained rapidly. To assess this hypothesis, Experiment 1 examined masked priming effects in Arabic for native speakers of Arabic, whereas participants in Experiments 2 and 3 were lower intermediate learners of Arabic and readers with no knowledge of Arabic, respectively. Results showed a masked priming effect only for readers who are familiar with the Arabic script. Furthermore, transposed-letter priming in native speakers of Arabic only occurred when the order of the root letters was kept intact. In Experiments 3-7, we examined why masked repetition priming is absent for readers who are unfamiliar with the Arabic script. We discuss the implications of these findings for models of visual-word recognition.
Dry etching technologies for reflective multilayer
NASA Astrophysics Data System (ADS)
Iino, Yoshinori; Karyu, Makoto; Ita, Hirotsugu; Kase, Yoshihisa; Yoshimori, Tomoaki; Muto, Makoto; Nonaka, Mikio; Iwami, Munenori
2012-11-01
We have developed a highly integrated methodology for patterning Extreme Ultraviolet (EUV) mask, which has been highlighted for the lithography technique at the 14nm half-pitch generation and beyond. The EUV mask is characterized as a reflective-type mask which is completely different compared with conventional transparent-type of photo mask. And it requires not only patterning of absorber layer without damaging the underlying multi reflective layers (40 Si/Mo layers) but also etching multi reflective layers. In this case, the dry etch process has generally faced technical challenges such as the difficulties in CD control, etch damage to quartz substrate and low selectivity to the mask resist. Shibaura Mechatronics ARESTM mask etch system and its optimized etch process has already achieved the maximal etch performance at patterning two-layered absorber. And in this study, our process technologies of multi reflective layers will be evaluated by means of optimal combination of process gases and our optimized plasma produced by certain source power and bias power. When our ARES™ is used for multilayer etching, the user can choose to etch the absorber layer at the same time or etch only the multilayer.
Li, W; Thier, P; Wehrhahn, C
2000-02-01
We studied the effects of various patterns as contextual stimuli on human orientation discrimination, and on responses of neurons in V1 of alert monkeys. When a target line is presented along with various contextual stimuli (masks), human orientation discrimination is impaired. For most V1 neurons, responses elicited by a line in the receptive field (RF) center are suppressed by these contextual patterns. Orientation discrimination thresholds of human observers are elevated slightly when the target line is surrounded by orthogonal lines. For randomly oriented lines, thresholds are elevated further and even more so for lines parallel to the target. Correspondingly, responses of most V1 neurons to a line are suppressed. Although contextual lines inhibit the amplitude of orientation tuning functions of most V1 neurons, they do not systematically alter the tuning width. Elevation of human orientation discrimination thresholds decreases with increasing curvature of masking lines, so does the inhibition of V1 neuronal responses. A mask made of straight lines yields the strongest interference with human orientation discrimination and produces the strongest suppression of neuronal responses. Elevation of human orientation discrimination thresholds is highest when a mask covers only the immediate vicinity of the target line. Increasing the masking area results in less interference. On the contrary, suppression of neuronal responses in V1 increases with increasing mask size. Our data imply that contextual interference observed in human orientation discrimination is in part directly related to contextual inhibition of neuronal activity in V1. However, the finding that interference with orientation discrimination is weaker for larger masks suggests a figure-ground segregation process that is not located in V1.
Kelishadi, Roya; Salek, Shadi; Salek, Mehdi; Hashemipour, Mahin; Movahedian, Mahsa
2014-01-01
This triple-masked controlled trial aimed to assess the effects of vitamin D supplementation on insulin resistance and cardiometabolic risk factors in obese children and adolescents. The study comprised 50 participants, aged 10 to 16 years, who were randomly assigned into two groups of equal number. In this 12-week trial, one group received oral vitamin D (300,000 IU) and the other group received placebo. Cardiometabolic risk factors, insulin resistance, and a continuous value of metabolic syndrome (cMetS) were determined. Statistical analysis was conducted after adjustment for covariate interactions. Overall, 21 patients in the vitamin D group and 22 in the placebo group completed the trial. No significant difference was observed in the baseline characteristics of the two groups. After the trial, in the vitamin D group, serum insulin and triglyceride concentrations, as well as HOM -IR and C-MetS decreased significantly, both when compared with the baseline and with the placebo group. No significant difference was observed when comparing total cholesterol, LDL-C, HDL-C, fasting blood glucose, and blood pressure. The present findings support the favorable effects of vitamin D supplementation on reducing insulin resistance and cardiometabolic risk factors in obese children. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
HCIT Contrast Performance Sensitivity Studies: Simulation Versus Experiment
NASA Technical Reports Server (NTRS)
Sidick, Erkin; Shaklan, Stuart; Krist, John; Cady, Eric J.; Kern, Brian; Balasubramanian, Kunjithapatham
2013-01-01
Using NASA's High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory, we have experimentally investigated the sensitivity of dark hole contrast in a Lyot coronagraph for the following factors: 1) Lateral and longitudinal translation of an occulting mask; 2) An opaque spot on the occulting mask; 3) Sizes of the controlled dark hole area. Also, we compared the measured results with simulations obtained using both MACOS (Modeling and Analysis for Controlled Optical Systems) and PROPER optical analysis programs with full three-dimensional near-field diffraction analysis to model HCIT's optical train and coronagraph.
Binaural masking release in children with Down syndrome.
Porter, Heather L; Grantham, D Wesley; Ashmead, Daniel H; Tharpe, Anne Marie
2014-01-01
Binaural hearing results in a number of listening advantages relative to monaural hearing, including enhanced hearing sensitivity and better speech understanding in adverse listening conditions. These advantages are facilitated in part by the ability to detect and use interaural cues within the central auditory system. Binaural hearing for children with Down syndrome could be impacted by multiple factors including, structural anomalies within the peripheral and central auditory system, alterations in synaptic communication, and chronic otitis media with effusion. However, binaural hearing capabilities have not been investigated in these children. This study tested the hypothesis that children with Down syndrome experience less binaural benefit than typically developing peers. Participants included children with Down syndrome aged 6 to 16 years (n = 11), typically developing children aged 3 to 12 years (n = 46), adults with Down syndrome (n = 3), and adults with no known neurological delays (n = 6). Inclusionary criteria included normal to near-normal hearing sensitivity. Two tasks were used to assess binaural ability. Masking level difference (MLD) was calculated by comparing threshold for a 500-Hz pure-tone signal in 300-Hz wide Gaussian noise for N0S0 and N0Sπ signal configurations. Binaural intelligibility level difference was calculated using simulated free-field conditions. Speech recognition threshold was measured for closed-set spondees presented from 0-degree azimuth in speech-shaped noise presented from 0-, 45- and 90-degree azimuth, respectively. The developmental ability of children with Down syndrome was estimated and information regarding history of otitis media was obtained for all child participants via parent survey. Individuals with Down syndrome had higher masked thresholds for pure-tone and speech stimuli than typically developing individuals. Children with Down syndrome had significantly smaller MLDs than typically developing children. Adults with Down syndrome and control adults had similar MLDs. Similarities in simulated spatial release from masking were observed for all groups for the experimental parameters used in this study. No association was observed for any measure of binaural ability and developmental age for children with Down syndrome. Similar group psychometric functions were observed for children with Down syndrome and typically developing children in most instances, suggesting that attentiveness and motivation contributed equally to performance for both groups on most tasks. The binaural advantages afforded to typically developing children, such as enhanced hearing sensitivity in noise, were not as robust for children with Down syndrome in this study. Children with Down syndrome experienced less binaural benefit than typically developing peers for some stimuli, suggesting that they could require more favorable signal-to-noise ratios to achieve optimal performance in some adverse listening conditions. The reduced release from masking observed for children with Down syndrome could represent a delay in ability rather than a deficit that persists into adulthood. This could have implications for the planning of interventions for individuals with Down syndrome.
Drašković, Milica; Medarević, Djordje; Aleksić, Ivana; Parojčić, Jelena
2017-05-01
Considering that bitter taste of drugs incorporated in orally disintegrating tablets (ODTs) can be the main reason for avoiding drug therapy, it is of the utmost importance to achieve successful taste-masking. The evaluation of taste-masking effectiveness is still a major challenge. The objective of this study was to mask bitter taste of the selected model drugs by drug particle coating with Eudragit ® E PO, as well as to evaluate taste-masking effectiveness of prepared ODTs using compendial dissolution testing, dissolution in the small-volume shake-flask assembly and trained human taste panel. Model drugs were coated in fluidized bed. Disintequik™ ODT was used as a novel co-processed excipient for ODT preparation. Selected formulations were investigated in vitro and in vivo using techniques for taste-masking assessment. Significantly slower drug dissolution was observed from tablets with coated drug particles during the first 3 min of investigation. Results of in vivo taste-masking assessment demonstrated significant improvement in drug bitterness suppression in formulations with coated drug. Strong correlation between the results of drug dissolution in the small-volume shake-flask assembly and in vivo evaluation data was established (R ≥ 0.970). Drug particle coating with Eudragit ® E PO can be a suitable approach for bitter taste-masking. Strong correlation between in vivo and in vitro results implicate that small-volume dissolution method may be used as surrogate for human panel taste-masking assessment, in the case of physical taste-masking approach application.
Investigation of phase distribution using Phame® in-die phase measurements
NASA Astrophysics Data System (ADS)
Buttgereit, Ute; Perlitz, Sascha
2009-03-01
As lithography mask processes move toward 45nm and 32nm node, mask complexity increases steadily, mask specifications tighten and process control becomes extremely important. Driven by this fact the requirements for metrology tools increase as well. Efforts in metrology have been focused on accurately measuring CD linearity and uniformity across the mask, and accurately measuring phase variation on Alternating/Attenuated PSM and transmission for Attenuated PSM. CD control on photo masks is usually done through the following processes: exposure dose/focus change, resist develop and dry etch. The key requirement is to maintain correct CD linearity and uniformity across the mask. For PSM specifically, the effect of CD uniformity for both Alternating PSM and Attenuated PSM and etch depth for Alternating PSM becomes also important. So far phase measurement has been limited to either measuring large-feature phase using interferometer-based metrology tools or measuring etch depth using AFM and converting etch depth into phase under the assumption that trench profile and optical properties of the layers remain constant. However recent investigations show that the trench profile and optical property of layers impact the phase. This effect is getting larger for smaller CD's. The currently used phase measurement methods run into limitations because they are not able to capture 3D mask effects, diffraction limitations or polarization effects. The new phase metrology system - Phame(R) developed by Carl Zeiss SMS overcomes those limitations and enables laterally resolved phase measurement in any kind of production feature on the mask. The resolution of the system goes down to 120nm half pitch at mask level. We will report on tool performance data with respect to static and dynamic phase repeatability focusing on Alternating PSM. Furthermore the phase metrology system was used to investigate mask process signatures on Alternating PSM in order to further improve the overall PSM process performance. Especially global loading effects caused by the pattern density and micro loading effects caused by the feature size itself have been evaluated using the capability of measuring phase in the small production features. The results of this study will be reported in this paper.
Contrast gain control in first- and second-order motion perception.
Lu, Z L; Sperling, G
1996-12-01
A novel pedestal-plus-test paradigm is used to determine the nonlinear gain-control properties of the first-order (luminance) and the second-order (texture-contrast) motion systems, that is, how these systems' responses to motion stimuli are reduced by pedestals and other masking stimuli. Motion-direction thresholds were measured for test stimuli consisting of drifting luminance and texture-contrast-modulation stimuli superimposed on pedestals of various amplitudes. (A pedestal is a static sine-wave grating of the same type and same spatial frequency as the moving test grating.) It was found that first-order motion-direction thresholds are unaffected by small pedestals, but at pedestal contrasts above 1-2% (5-10 x pedestal threshold), motion thresholds increase proportionally to pedestal amplitude (a Weber law). For first-order stimuli, pedestal masking is specific to the spatial frequency of the test. On the other hand, motion-direction thresholds for texture-contrast stimuli are independent of pedestal amplitude (no gain control whatever) throughout the accessible pedestal amplitude range (from 0 to 40%). However, when baseline carrier contrast increases (with constant pedestal modulation amplitude), motion thresholds increase, showing that gain control in second-order motion is determined not by the modulator (as in first-order motion) but by the carrier. Note that baseline contrast of the carrier is inherently independent of spatial frequency of the modulator. The drastically different gain-control properties of the two motion systems and prior observations of motion masking and motion saturation are all encompassed in a functional theory. The stimulus inputs to both first- and second-order motion process are normalized by feedforward, shunting gain control. The different properties arise because the modulator is used to control the first-order gain and the carrier is used to control the second-order gain.
Masking technique for coating thickness control on large and strongly curved aspherical optics.
Sassolas, B; Flaminio, R; Franc, J; Michel, C; Montorio, J-L; Morgado, N; Pinard, L
2009-07-01
We discuss a method to control the coating thickness deposited onto large and strongly curved optics by ion beam sputtering. The technique uses an original design of the mask used to screen part of the sputtered materials. A first multielement mask is calculated from the measured two-dimensional coating thickness distribution. Then, by means of an iterative process, the final mask is designed. By using such a technique, it has been possible to deposit layers of tantalum pentoxide having a high thickness gradient onto a curved substrate 500 mm in diameter. Residual errors in the coating thickness profile are below 0.7%.
Masked and unmasked error-related potentials during continuous control and feedback
NASA Astrophysics Data System (ADS)
Lopes Dias, Catarina; Sburlea, Andreea I.; Müller-Putz, Gernot R.
2018-06-01
The detection of error-related potentials (ErrPs) in tasks with discrete feedback is well established in the brain–computer interface (BCI) field. However, the decoding of ErrPs in tasks with continuous feedback is still in its early stages. Objective. We developed a task in which subjects have continuous control of a cursor’s position by means of a joystick. The cursor’s position was shown to the participants in two different modalities of continuous feedback: normal and jittered. The jittered feedback was created to mimic the instability that could exist if participants controlled the trajectory directly with brain signals. Approach. This paper studies the electroencephalographic (EEG)—measurable signatures caused by a loss of control over the cursor’s trajectory, causing a target miss. Main results. In both feedback modalities, time-locked potentials revealed the typical frontal-central components of error-related potentials. Errors occurring during the jittered feedback (masked errors) were delayed in comparison to errors occurring during normal feedback (unmasked errors). Masked errors displayed lower peak amplitudes than unmasked errors. Time-locked classification analysis allowed a good distinction between correct and error classes (average Cohen-, average TPR = 81.8% and average TNR = 96.4%). Time-locked classification analysis between masked error and unmasked error classes revealed results at chance level (average Cohen-, average TPR = 60.9% and average TNR = 58.3%). Afterwards, we performed asynchronous detection of ErrPs, combining both masked and unmasked trials. The asynchronous detection of ErrPs in a simulated online scenario resulted in an average TNR of 84.0% and in an average TPR of 64.9%. Significance. The time-locked classification results suggest that the masked and unmasked errors were indistinguishable in terms of classification. The asynchronous classification results suggest that the feedback modality did not hinder the asynchronous detection of ErrPs.
Model of visual contrast gain control and pattern masking
NASA Technical Reports Server (NTRS)
Watson, A. B.; Solomon, J. A.
1997-01-01
We have implemented a model of contrast gain and control in human vision that incorporates a number of key features, including a contrast sensitivity function, multiple oriented bandpass channels, accelerating nonlinearities, and a devisive inhibitory gain control pool. The parameters of this model have been optimized through a fit to the recent data that describe masking of a Gabor function by cosine and Gabor masks [J. M. Foley, "Human luminance pattern mechanisms: masking experiments require a new model," J. Opt. Soc. Am. A 11, 1710 (1994)]. The model achieves a good fit to the data. We also demonstrate how the concept of recruitment may accommodate a variant of this model in which excitatory and inhibitory paths have a common accelerating nonlinearity, but which include multiple channels tuned to different levels of contrast.
NASA Technical Reports Server (NTRS)
Ahumada, Albert J.; Beard, B. L.; Stone, Leland (Technical Monitor)
1997-01-01
We have been developing a simplified spatial-temporal discrimination model similar to our simplified spatial model in that masking is assumed to be a function of the local visible contrast energy. The overall spatial-temporal sensitivity of the model is calibrated to predict the detectability of targets on a uniform background. To calibrate the spatial-temporal integration functions that define local visible contrast energy, spatial-temporal masking data are required. Observer thresholds were measured (2IFC) for the detection of a 12 msec target stimulus in the presence of a 700 msec mask. Targets were 1, 3 or 9 c/deg sine wave gratings. Masks were either one of these gratings or two of them combined. The target was presented in 17 temporal positions with respect to the mask, including positions before, during and after the mask. Peak masking was found near mask onset and offset for 1 and 3 c/deg targets, while masking effects were more nearly uniform during the mask for the 9 c/deg target. As in the purely spatial case, the simplified model can not predict all the details of masking as a function of masking component spatial frequencies, but overall the prediction errors are small.
Effects of non-simultaneous masking on the binaural masking level difference
Buss, Emily; Hall III, Joseph W.
2011-01-01
The present study sought to clarify the role of non-simultaneous masking in the binaural masking level difference for maskers that fluctuate in level. In the first experiment the signal was a brief 500-Hz tone, and the masker was a bandpass noise (100–2000 Hz), with the initial and final 200-ms bursts presented at 40-dB spectrum level and the inter-burst gap presented at 20-dB spectrum level. Temporal windows were fitted to thresholds measured for a range of gap durations and signal positions within the gap. In the second experiment, individual differences in out of phase (NoSπ) thresholds were compared for a brief signal in a gapped bandpass masker, a brief signal in a steady bandpass masker, and a long signal in a narrowband (50-Hz-wide) noise masker. The third experiment measured brief tone detection thresholds in forward, simultaneous, and backward masking conditions for a 50- and for a 1900-Hz-wide noise masker centered on the 500-Hz signal frequency. Results are consistent with comparable temporal resolution in the in phase (NoSo) and NoSπ conditions and no effect of temporal resolution on individual observers’ ability to utilize binaural cues in narrowband noise. The large masking release observed for a narrowband noise masker may be due to binaural masking release from non-simultaneous, informational masking. PMID:21361448
Effect of Ibuprofen on masking endodontic diagnosis.
Read, Jason K; McClanahan, Scott B; Khan, Asma A; Lunos, Scott; Bowles, Walter R
2014-08-01
An accurate diagnosis is of upmost importance before initiating endodontic treatment; yet, there are occasions when the practitioner cannot reproduce the patient's chief complaint because the patient has become asymptomatic. Ibuprofen taken beforehand may "mask" or eliminate the patient's symptoms. In fact, 64%-83% of patients with dental pain take analgesics before seeing a dentist. The purpose of this study was to examine the possible "masking" effect of ibuprofen on endodontic diagnostic tests. Forty-two patients with endodontic pain underwent testing (cold, percussion, palpation, and bite force measurement) and then received either placebo or 800 mg ibuprofen. Both patients and operators were blinded to the medication received. One hour later, diagnostic testing was repeated and compared with pretreatment testing. Ibuprofen affected testing values for vital teeth by masking palpation 40%, percussion 25%, and cold 25% on affected teeth with symptomatic irreversible pulpitis and symptomatic apical periodontitis. There was no observed masking effect in the placebo group on palpation, percussion, or cold values. When nonvital teeth were included, the masking effect of ibuprofen was decreased. However, little masking occurred with the bite force measurement differences. Analgesics taken before the dental appointment can affect endodontic diagnostic testing results. Bite force measurements can assist in identifying the offending tooth in cases in which analgesics "mask" the endodontic diagnosis. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Model-based MPC enables curvilinear ILT using either VSB or multi-beam mask writers
NASA Astrophysics Data System (ADS)
Pang, Linyong; Takatsukasa, Yutetsu; Hara, Daisuke; Pomerantsev, Michael; Su, Bo; Fujimura, Aki
2017-07-01
Inverse Lithography Technology (ILT) is becoming the choice for Optical Proximity Correction (OPC) of advanced technology nodes in IC design and production. Multi-beam mask writers promise significant mask writing time reduction for complex ILT style masks. Before multi-beam mask writers become the main stream working tools in mask production, VSB writers will continue to be the tool of choice to write both curvilinear ILT and Manhattanized ILT masks. To enable VSB mask writers for complex ILT style masks, model-based mask process correction (MB-MPC) is required to do the following: 1). Make reasonable corrections for complex edges for those features that exhibit relatively large deviations from both curvilinear ILT and Manhattanized ILT designs. 2). Control and manage both Edge Placement Errors (EPE) and shot count. 3. Assist in easing the migration to future multi-beam mask writer and serve as an effective backup solution during the transition. In this paper, a solution meeting all those requirements, MB-MPC with GPU acceleration, will be presented. One model calibration per process allows accurate correction regardless of the target mask writer.
Refinement of the CALIOP cloud mask algorithm
NASA Astrophysics Data System (ADS)
Katagiri, Shuichiro; Sato, Kaori; Ohta, Kohei; Okamoto, Hajime
2018-04-01
A modified cloud mask algorithm was applied to the CALIOP data to have more ability to detect the clouds in the lower atmosphere. In this algorithm, we also adopt the fully attenuation discrimination and the remain noise estimation using the data obtained at an altitude of 40 km to avoid contamination of stratospheric aerosols. The new cloud mask shows an increase in the lower cloud fraction. Comparison of the results to the data observed with a PML ground observation was also made.
Method To Display Data On A Face Mask
NASA Technical Reports Server (NTRS)
Moore, Kevin-Duron
1995-01-01
Proposed electronic instrument displays information on diver's or firefighter's face mask. Includes mask, prism, electronic readouts, transceiver and control electronics. Mounted at periphery of diver's field of view to provide data on elapsed time, depth, pressure, and temperature. Provides greater safety and convenience to user.
Tiwari, Roshan V.; Polk, Ashley N.; Patil, Hemlata; Ye, Xingyou; Pimparade, Manjeet B.; Repka, Michael A.
2017-01-01
Developing a pediatric oral formulation with an age-appropriate dosage form and taste masking of naturally bitter active pharmaceutical ingredients (APIs) are key challenges for formulation scientists. Several techniques are used for taste masking of bitter APIs to improve formulation palatability; however, not all the techniques are applicable to pediatric dosage forms because of the limitations on the kind and concentration of the excipients that can be used. Hot-melt extrusion (HME) technology is used successfully for taste masking of bitter APIs, and overcomes some of the limitations of the existing taste masking techniques. Likewise, analytical taste assessment is an important quality control parameter evaluated by several in vivo and in vitro methods, such as the human taste panel, electrophysiological methods, electronic sensor, and animal preference tests to aid in selecting a taste-masked formulation. However, the most appropriate in-vivo method to assess the taste-masking efficacy of pediatric formulations remains unknown, because it is not known to what extent the human taste panel/electronic tongue can predict the palatability in the pediatric patients. The purpose of this study was to develop taste-masked caffeine citrate extrudates via HME, and to demonstrate the wide applicability of a single bottle-test rat model to record and compare the volume consumed of the taste-masked solutions to that of the pure API. Thus, this rat model can be considered as a low-cost alternative taste-assessment method to the most commonly used expensive human taste panel/electronic tongue method for pediatric formulations. PMID:26573158
Spatial and directional control of self-assembled wrinkle patterns by UV light absorption
NASA Astrophysics Data System (ADS)
Kortz, C.; Oesterschulze, E.
2017-12-01
Wrinkle formation on surfaces is a phenomenon that is observed in layered systems with a compressed elastic thin capping layer residing on a viscoelastic film. So far, the properties of the viscoelastic material could only be changed replacing it by another material. Here, we propose to use a photosensitive material whose viscoelastic properties, Young's modulus, and glass transition temperature can easily be adjusted by the absorption of UV light. Employing UV lithography masks during the exposure, we gain additionally spatial and directional control of the self-assembled wrinkle pattern formation that relies on a spinodal decomposition process. Inspired by the results on surface wrinkling and its dependence on the intrinsic stress, we also derive a method to avoid wrinkling locally by tailoring the mechanical stress distribution in the layered system choosing UV masks with convex patterns. This is of particular interest in technical applications where the buckling of surfaces is undesirable.
Hyper-realistic face masks: a new challenge in person identification.
Sanders, Jet Gabrielle; Ueda, Yoshiyuki; Minemoto, Kazusa; Noyes, Eilidh; Yoshikawa, Sakiko; Jenkins, Rob
2017-01-01
We often identify people using face images. This is true in occupational settings such as passport control as well as in everyday social environments. Mapping between images and identities assumes that facial appearance is stable within certain bounds. For example, a person's apparent age, gender and ethnicity change slowly, if at all. It also assumes that deliberate changes beyond these bounds (i.e., disguises) would be easy to spot. Hyper-realistic face masks overturn these assumptions by allowing the wearer to look like an entirely different person. If unnoticed, these masks break the link between facial appearance and personal identity, with clear implications for applied face recognition. However, to date, no one has assessed the realism of these masks, or specified conditions under which they may be accepted as real faces. Herein, we examined incidental detection of unexpected but attended hyper-realistic masks in both photographic and live presentations. Experiment 1 (UK; n = 60) revealed no evidence for overt detection of hyper-realistic masks among real face photos, and little evidence of covert detection. Experiment 2 (Japan; n = 60) extended these findings to different masks, mask-wearers and participant pools. In Experiment 3 (UK and Japan; n = 407), passers-by failed to notice that a live confederate was wearing a hyper-realistic mask and showed limited evidence of covert detection, even at close viewing distance (5 vs. 20 m). Across all of these studies, viewers accepted hyper-realistic masks as real faces. Specific countermeasures will be required if detection rates are to be improved.
NASA Technical Reports Server (NTRS)
Rushby, John
1991-01-01
The formal specification and mechanically checked verification for a model of fault-masking and transient-recovery among the replicated computers of digital flight-control systems are presented. The verification establishes, subject to certain carefully stated assumptions, that faults among the component computers are masked so that commands sent to the actuators are the same as those that would be sent by a single computer that suffers no failures.
Masks For Deposition Of Aspherical Optical Surfaces
NASA Technical Reports Server (NTRS)
Rogers, John R.; Martin, John D.
1992-01-01
Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.
Current status of x-ray mask manufacturing at the Microlithographic Mask Development Center
NASA Astrophysics Data System (ADS)
Kimmel, Kurt R.; Hughes, Patrick J.
1996-07-01
The Microlithographic Mask Development Center (MMD) has been the focal point of X-ray mask development efforts in the United States since its inception in 1993. Funded by the Advanced Research Projects Agency (ARPA), and with technical support from the Proximity X-ray Lithography Association (AT&T, IBM, Loral Federal Systems, and Motorola) the MMD has recently made dramatic advances in mask fabrication. Numerous defect-free 64Mb and 256Mb DRAM masks have been made on both boron-doped silicon and silicon carbide substrates. Image-placement error of less than 35nm 3 sigma is achieved with high yield. Image-size (critical dimension) control of 25nm 3 sigma on 250nm nominal images is representative performance. This progress is being made in a manufacturing environment with significant volumes, multiple customers, multiple substrate configurations, and fast turnaround-time (TAT) requirements. The MMD state-of-the-art equipment infrastructure has made much of this progress possible. This year the MMD qualified the EL-4, an IBM-designed-and-built variable-shaped-spot e-beam system. The fundamental performance parameters of this system will be described. Operational techniques of multiple partial exposure writing and product specific emulation (PSE) have been implemented to improve image-placement accuracy with remarkable success. Image-size control was studied in detail with contributory components separated. Defect density was systematically reduced to yield defect-free masks while simultaneously tightening inspection criteria. Information about these and other recent engineering highlights will be reported. An outline of the primary engineering challenges and goals for 1996 and status of progress toward 100 nm design rule capability will also be given.
Thermometric titration of thorium with EDTA in the presence of large excess of neutral sodium salts.
Doi, K
1980-11-01
The thermometric titration of Th(IV) in the presence of neutral sodium salts, sulphuric acid or acetic acid with EDTA has been studied. The effect of each on the observed heat values for the titration is discussed. For sodium perchlorate media, DeltaH values of -9 and -21 kJ/mole have been estimated for the formation of the Th(IV)-EDTA chelate at mu --> 0 and mu = 0.5 (NaClO(4)), respectively. The -DeltaH values increase steadily with increase in concentration of sodium perchlorate up to at least 3M. For the titration of Th(IV) in the presence of a large excess of sodium nitrate the use of sodium iodide as a masking reagent has been examined: large amounts of Bi and Cu(II) are masked and a masking effect is observed for small amounts of Ni.
Surgical Face Masks Worn by Patients with Multidrug-Resistant Tuberculosis
Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A.; van der Walt, Martie; Nardell, Edward A.
2012-01-01
Rationale: Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. Objectives: We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Methods: Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Measurements and Main Results: Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68–85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31–51%), representing a 56% (95% CI, 33–70.5%) decreased risk of TB transmission when patients used masks. Conclusions: Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients. PMID:22323300
Masking as an effective quality control method for next-generation sequencing data analysis.
Yun, Sajung; Yun, Sijung
2014-12-13
Next generation sequencing produces base calls with low quality scores that can affect the accuracy of identifying simple nucleotide variation calls, including single nucleotide polymorphisms and small insertions and deletions. Here we compare the effectiveness of two data preprocessing methods, masking and trimming, and the accuracy of simple nucleotide variation calls on whole-genome sequence data from Caenorhabditis elegans. Masking substitutes low quality base calls with 'N's (undetermined bases), whereas trimming removes low quality bases that results in a shorter read lengths. We demonstrate that masking is more effective than trimming in reducing the false-positive rate in single nucleotide polymorphism (SNP) calling. However, both of the preprocessing methods did not affect the false-negative rate in SNP calling with statistical significance compared to the data analysis without preprocessing. False-positive rate and false-negative rate for small insertions and deletions did not show differences between masking and trimming. We recommend masking over trimming as a more effective preprocessing method for next generation sequencing data analysis since masking reduces the false-positive rate in SNP calling without sacrificing the false-negative rate although trimming is more commonly used currently in the field. The perl script for masking is available at http://code.google.com/p/subn/. The sequencing data used in the study were deposited in the Sequence Read Archive (SRX450968 and SRX451773).
The Q Continuum: Encounter with the Cloud Mask
NASA Astrophysics Data System (ADS)
Ackerman, S. A.; Frey, R.; Holz, R.; Philips, C.; Dutcher, S.
2017-12-01
We are developing a common cloud mask for MODIS and VIIRS observations, referred to as the MODIS VIIRS Continuity Mask (MVCM). Our focus is on extending the MODIS-heritage cloud detection approach in order to generate appropriate climate data records for clouds and climate studies. The MVCM is based on heritage from the MODIS cloud mask (MOD35 and MYD35) and employs a series of tests on MODIS reflectances and brightness temperatures. Cloud detection is based on contrasts (i.e., cloud versus background surface) at pixel resolution. The MVCM follows the same approach. These cloud masks use multiple cloud detection tests to indicate the confidence level that the observation is of a clear-sky scene. The outcome of a test ranges from 0 (cloudy) to 1 (clear-sky scene). Because of overlap in the sensitivities of the various spectral tests to the type of cloud, each test is considered in one of several groups. The final cloud mask is determined from the product of the minimum confidence of each group and is referred to as the Q value as defined in Ackerman et al (1998). In MOD35 and MYD35 processing, the Q value is not output, rather predetermined Q values determine the result: If Q ≥ .99 the scene is clear; .95 ≤ Q < .99 the pixel is probably a clear scene, .66 ≤ Q < .95 is probably cloudy and Q < .66 is cloudy. Thus representing Q discretely and not as a continuum. For the MVCM, the numerical value of the Q is output along with the classification of clear, probably clear, probably cloudy, and cloudy. Through comparisons with collocated CALIOP and MODIS observations, we will assess the categorization of the Q values as a function of scene type ). While validation studies have indicated the utility and statistical correctness of the cloud mask approach, the algorithm does not possess immeasurable power and perfection. This comparison will assess the time and space dependence of Q and assure that the laws of physics are followed, at least according to normal human notions. Using CALIOP as representing truth, a receiver operating characteristic curve (ROC) will be analyzed to determine the optimum Q for various scenes and seasons, thus providing a continuum of discriminating thresholds.
Emulating JWST/NIRCam Exoplanet Transit Observations in a Testbed laboratory experiment
NASA Astrophysics Data System (ADS)
Touli-Lebreton, D.; Vasisht, G.; Smith, R.; Krist, J.; Beichman, C.
2014-03-01
The transit technique is used for the detection and characterization of exoplanets. The combination of a transit measurement with a radial velocity measurement gives information about a planet's radius and mass, respectively, leading to an estimate of the planet's density and therefore to its composition and evolutionary history. Spectroscopic observations of individual planets have revealed atomic and molecular species such as H2O, CO2 and CH4 in atmospheres of planets orbiting bright stars, e.g. Deming et al 2013. These transit observations require extremely precise photometry. For instance, Jupiter transit results to a 1% brightness decrease of a solar type star while the Earth causes only a 0.0084% decrease (84 ppm). In our controlled laboratory experiment, we use a H2RG detector, two lamps of variable intensity, along with spectral line and photometric simulation masks to emulate the signals from a star-only, from a planet-only and finally, from a combination of a planet + star. Two masks have been used to simulate spectra in monochromatic light. The masks are 1040 pixels in length with one mask having a 2-pixel width and the other a 10-pixel width. From many-hour long observing sequences we obtain time series photometry with deliberate offsets introduced to test sensitivity to pointing jitter and other effects. We can modify the star- planet brightness contrast by factors up to 104:1. With cross correlation techniques we calculate positional shifts which are then used to decorrelate the effects of vertical and lateral offsets due to turbulence and instrumental vibrations on the photometry. Using Principal Component Analysis (PCA), we reject correlated temporal noise to achieve a precision lower than 50 ppm (Clanton et al 2012). Testbed experiments are ongoing to provide quantitative information on the achievable spectroscopic precision using realistic exoplanet spectra with the goal to define optimized data acquisition sequences for use, for example, with the James Webb Space Telescope.
JAPE 91: Influence of terrain masking of the acoustic propagation of helicopter noise
NASA Technical Reports Server (NTRS)
Naz, P.
1993-01-01
The acoustic propagation in the case of a noise source masked by a small element of terrain has been investigated experimentally. These data have been measured during the 'terrain masking' experiment of the NATO JAPE 91 experimental campaign. The main objective of that experiment was to study the acoustic detection of a helicopter masked by a small hill. Microphones have been placed at different locations on the shadow zone of the hill to study the effect of the terrain obstruction on sound propagation. The results presented come from data measured by Atlas Elektronik and by ISL, and have been processed together. The terrain obstruction causes an excess attenuation of the SPL (Sound Pressure Level) for all the frequencies, but this attenuation is more effective for the high frequencies than for the low frequencies. Results typical of diffraction phenomena have been observed; the SPL is minimal at the foot of the hill and is relatively constant beyond it.
Eddy, Marianna D; Holcomb, Phillip J
2010-06-22
The current study used event-related potentials (ERPs) and masked repetition priming to examine the time-course of picture processing. We manipulated the stimulus-onset asynchrony (110 ms, 230 ms, 350 ms, and 470 ms) between repeated and unrepeated prime-target pairs while holding the prime duration constant (50 ms) (Experiment 1) as well as the prime durations (30 ms, 50 ms, 70 ms, and 90 ms) (Experiment 2) with a constant SOA of 110 ms in a masked repetition priming paradigm with pictures. The aim of this study was to further elucidate the mechanisms underlying previously observed ERP components in masked priming with pictures. We found that both the N/P190 and N400 are modulated by changes in prime duration and SOA, however, it appears that longer prime exposure rather than a longer SOA leads to more in-depth processing as indexed by larger N400 effects. (c) 2010 Elsevier B.V. All rights reserved.
Castaño-García, Alberto; Guillén-Grima, Francisco; León-Sanz, Pilar
2018-01-01
To evaluate some methodological and ethical quality variables of clinical trials (CTs) published in 10 family medicine journals. Quality descriptive study of 10 family medicine journals including CTs in humans published since 2010 to 2013. We obtained 141 CT and 2447 were excluded. CTs parallels controlled in 92.9% (95% confidence interval [95% CI]: 92.0-93.9). Masked randomization in 72.3% (95% CI: 71.7-73.1), decentralized in 51.8% (95% CI: 51.4-52.4) and using as control an active treatment in 82.2% (95% CI: 81.5-83.1). Wrote informed consent in 48.9% (95% CI: 48.5-49.5) and it was not withdrawn in 56.0% of cases (95% CI: 55.5-56.7). Approval by clinical research ethics committee (CREC) in 134, and there was no conflict of interest in 117 CTs. Average κ was 0.96 (95% CI: 0.93-0.99). We observe an increase in some quality variables like masked randomization (19.6%) and approval by CREC (75%) post CONSORT, in CTs published in 10 family medicine journals (2010-2013). Copyright: © 2018 SecretarÍa de Salud
The CD control improvement by using CDSEM 2D measurement of complex OPC patterns
NASA Astrophysics Data System (ADS)
Chou, William; Cheng, Jeffrey; Lee, Adder; Cheng, James; Tzeng, Alex C.; Lu, Colbert; Yang, Ray; Lee, Hong Jen; Bandoh, Hideaki; Santo, Izumi; Zhang, Hao; Chen, Chien Kang
2016-10-01
As the process node becomes more advanced, the accuracy and precision in OPC pattern CD are required in mask manufacturing. CD SEM is an essential tool to confirm the mask quality such as CD control, CD uniformity and CD mean to target (MTT). Unfortunately, in some cases of arbitrary enclosed patterns or aggressive OPC patterns, for instance, line with tiny jogs and curvilinear SRAF, CD variation depending on region of interest (ROI) is a very serious problem in mask CD control, even it decreases the wafer yield. For overcoming this situation, the 2-dimensional (2D) method by Holon is adopted. In this paper, we summarize the comparisons of error budget between conventional (1D) and 2D data using CD SEM and the CD performance between mask and wafer by complex OPC patterns including ILT features.
Impact of the flu mask regulation on health care personnel influenza vaccine acceptance rates.
Edwards, Frances; Masick, Kevin D; Armellino, Donna
2016-10-01
Achieving high vaccination rates of health care personnel (HCP) is critical in preventing influenza transmission from HCP to patients and from patients to HCP; however, acceptance rates remain low. In 2013, New York State adopted the flu mask regulation, requiring unvaccinated HCP to wear a mask when in areas where patients are present. The purpose of this study assessed the impact of the flu mask regulation on the HCP influenza vaccination rate. A 13-question survey was distributed electronically and manually to the HCP to examine their knowledge of influenza transmission and the influenza vaccine and their personal vaccine acceptance history and perception about the use of the mask while working if not vaccinated. There were 1,905 respondents; 87% accepted the influenza vaccine, and 63% were first-time recipients who agreed the regulation influenced their vaccination decision. Of the respondents who declined the vaccine, 72% acknowledge HCP are at risk for transmitting influenza to patients, and 56% reported they did not receive enough information to make an educated decision. The flu mask protocol may have influenced HCP's choice to be vaccinated versus wearing a mask. The study findings supported that HCP may not have adequate knowledge on the morbidity and mortality associated with influenza. Regulatory agencies need to consider an alternative approach to increase HCP vaccination, such as mandating the influenza vaccine for HCP. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Spatial Release from Masking in Children: Effects of Simulated Unilateral Hearing Loss
Corbin, Nicole E.; Buss, Emily; Leibold, Lori J.
2016-01-01
Objectives The purpose of this study was twofold: 1) to determine the effect of an acute simulated unilateral hearing loss on children’s spatial release from masking in two-talker speech and speech-shaped noise, and 2) to develop a procedure to be used in future studies that will assess spatial release from masking in children who have permanent unilateral hearing loss. There were three main predictions. First, spatial release from masking was expected to be larger in two-talker speech than speech-shaped noise. Second, simulated unilateral hearing loss was expected to worsen performance in all listening conditions, but particularly in the spatially separated two-talker speech masker. Third, spatial release from masking was expected to be smaller for children than for adults in the two-talker masker. Design Participants were 12 children (8.7 to 10.9 yrs) and 11 adults (18.5 to 30.4 yrs) with normal bilateral hearing. Thresholds for 50%-correct recognition of Bamford-Kowal-Bench sentences were measured adaptively in continuous two-talker speech or speech-shaped noise. Target sentences were always presented from a loudspeaker at 0° azimuth. The masker stimulus was either co-located with the target or spatially separated to +90° or −90° azimuth. Spatial release from masking was quantified as the difference between thresholds obtained when the target and masker were co-located and thresholds obtained when the masker was presented from +90° or − 90°. Testing was completed both with and without a moderate simulated unilateral hearing loss, created with a foam earplug and supra-aural earmuff. A repeated-measures design was used to compare performance between children and adults, and performance in the no-plug and simulated-unilateral-hearing-loss conditions. Results All listeners benefited from spatial separation of target and masker stimuli on the azimuth plane in the no-plug listening conditions; this benefit was larger in two-talker speech than in speech-shaped noise. In the simulated-unilateral-hearing-loss conditions, a positive spatial release from masking was observed only when the masker was presented ipsilateral to the simulated unilateral hearing loss. In the speech-shaped noise masker, spatial release from masking in the no-plug condition was similar to that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. In contrast, in the two-talker speech masker, spatial release from masking in the no-plug condition was much larger than that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. When either masker was presented contralateral to the simulated unilateral hearing loss, spatial release from masking was negative. This pattern of results was observed for both children and adults, although children performed more poorly overall. Conclusions Children and adults with normal bilateral hearing experience greater spatial release from masking for a two-talker speech than a speech-shaped noise masker. Testing in a two-talker speech masker revealed listening difficulties in the presence of disrupted binaural input that were not observed in a speech-shaped noise masker. This procedure offers promise for the assessment of spatial release from masking in children with permanent unilateral hearing loss. PMID:27787392
DOE Office of Scientific and Technical Information (OSTI.GOV)
Band, L.; Xu, Heng; Bykov, V.
The present study demonstrates that pretreatment of rat brain membranes with (+)-cis-3-methylfentanyl ((+)-cis-MF), followed by extensive washing of the membranes, produces a wash-resistant decreasing in the binding of ({sup 3}H)-(D-ala{sup 2}, D-leu{sup 5})enkephalin to the d binding site of the opioid receptor complex ({delta}{sub cx} binding site). Intravenous administration of (+)-cis-MF (50 {mu}g/kg) to rats produced a pronounced catalepsy and also produced a wash-resistant masking of {delta}{sub cx} and {mu} binding sites in membranes prepared 120 min post-injection. Administration of 1 mg/kg i.v. of the opioid antagonist, 6-desoxy-6{beta}-fluoronaltrexone (cycloFOXY), 100 min after the injection of (+)-cis-MF (20 min prior tomore » the preparation of membranes) completely reversed the catatonia and restored masked {delta}{sub cx} binding sites to control levels. This was not observed with (+)-cycloFOXY. The implications of these and other findings for the mechanism of action of (+)-cis-MF and models of the opioid receptors are discussed.« less
Subliminal access to abstract face representations does not rely on attention.
Harry, Bronson; Davis, Chris; Kim, Jeesun
2012-03-01
The present study used masked repetition priming to examine whether face representations can be accessed without attention. Two experiments using a face recognition task (fame judgement) presented masked repetition and control primes in spatially unattended locations prior to target onset. Experiment 1 (n=20) used the same images as primes and as targets and Experiment 2 (n=17) used different images of the same individual as primes and targets. Repetition priming was observed across both experiments regardless of whether spatial attention was cued to the location of the prime. Priming occurred for both famous and non-famous targets in Experiment 1 but was only reliable for famous targets in Experiment 2, suggesting that priming in Experiment 1 indexed access to view-specific representations whereas priming in Experiment 2 indexed access to view-invariant, abstract representations. Overall, the results indicate that subliminal access to abstract face representations does not rely on attention. Copyright © 2011 Elsevier Inc. All rights reserved.
Method for maintaining precise suction strip porosities
NASA Technical Reports Server (NTRS)
Gallimore, Frank H. (Inventor)
1989-01-01
This invention relates to a masking method generally and, more particularly to a method of masking perforated titanium sheets having laminar control suction strips. As illustrated in the drawings, a nonaerodynamic surface of a perforated sheet has alternating suction strip areas and bonding land areas. Suction strip tapes overlie the bonding land areas during application of a masking material to an upper surface of the suction strip tapes. Prior to bonding the perforated sheet to a composite structure, the bonding land tapes are removed. The entire opposite aerodynamic surface is masked with tape before bonding. This invention provides a precise control of suction strip porosities by ensuring that no chemicals penetrate the suction strip areas during bonding.
Hot melt extrusion of ion-exchange resin for taste masking.
Tan, David Cheng Thiam; Ong, Jeremy Jianming; Gokhale, Rajeev; Heng, Paul Wan Sia
2018-05-30
Taste masking is important for some unpleasant tasting bioactives in oral dosage forms. Among many methods available for taste-masking, use of ion-exchange resin (IER) holds promise. IER combined with hot melt extrusion (HME) may offer additional advantages over solvent methods. IER provides taste masking by complexing with the drug ions and preventing drug dissolution in the mouth. Drug-IER complexation approaches described in literatures are mainly based either on batch processing or column eluting. These methods of drug-IER complexation have obvious limitations such as high solvent volume requirements, multiprocessing steps and extended processing time. Thus, the objective of this study was to develop a single-step, solvent-free, continuous HME process for complexation of drug-IER. The screening study evaluated drug to IER ratio, types of IER and drug complexation methods. In the screening study, a potassium salt of a weakly acidic carboxylate-based cationic IER was found suitable for the HME method. Thereafter, optimization study was conducted by varying HME process parameters such as screw speed, extrusion temperature and drug to IER ratio. It was observed that extrusion temperature and drug to IER ratio are imperative in drug-IER complexation through HME. In summary, this study has established the feasibility of a continuous complexation method for drug to IER using HME for taste masking. Copyright © 2018 Elsevier B.V. All rights reserved.
Masked priming effect reflects evidence accumulated by the prime.
Kinoshita, Sachiko; Norris, Dennis
2010-01-01
In the same-different match task, masked priming is observed with the same responses but not different responses. Norris and Kinoshita's (2008) Bayesian reader account of masked priming explains this pattern based on the same principle as that explaining the absence of priming for nonwords in the lexical decision task. The pattern of priming follows from the way the model makes optimal decisions in the two tasks; priming does not depend on first activating the prime and then the target. An alternative explanation is in terms of a bias towards responding "same" that exactly counters the facilitatory effect of lexical access. The present study tested these two views by varying both the degree to which the prime predicts the response and the visibility of the prime. Unmasked primes produced effects expected from the view that priming is influenced by the degree to which the prime predicts the response. In contrast, with masked primes, the size of priming for the same response was completely unaffected by predictability. These results rule out response bias as an explanation of the absence of masked priming for different responses and, in turn, indicate that masked priming is not a consequence of automatic lexical access of the prime.
Brzheskiy, Vladimir V; Efimova, Elena L; Vorontsova, Tatiana N; Alekseev, Vladimir N; Gusarevich, Olga G; Shaidurova, Ksenia N; Ryabtseva, Alla A; Andryukhina, Olga M; Kamenskikh, Tatiana G; Sumarokova, Elena S; Miljudin, Eugeny S; Egorov, Eugeny A; Lebedev, Oleg I; Surov, Alexander V; Korol, Andrii R; Nasinnyk, Illia O; Bezditko, Pavel A; Muzhychuk, Olena P; Vygodin, Vladimir A; Yani, Elena V; Savchenko, Alla Y; Karger, Elena M; Fedorkin, Oleg N; Mironov, Alexander N; Ostapenko, Victoria; Popeko, Natalia A; Skulachev, Vladimir P; Skulachev, Maxim V
2015-12-01
This article presents the results of an international, multicenter, randomized, double-masked, placebo-controlled clinical study of Visomitin (Mitotech LLC, Moscow, Russian Federation) eye drops in patients with dry eye syndrome (DES). Visomitin is the first registered (in Russia) drug with a mitochondria-targeted antioxidant (SkQ1) as the active ingredient. In this multicenter (10 sites) study of 240 subjects with DES, study drug (Visomitin or placebo) was self-administered three times daily (TID) for 6 weeks, followed by a 6-week follow-up period. Seven in-office study visits occurred every 2 weeks during both the treatment and follow-up periods. Efficacy measures included Schirmer's test, tear break-up time, fluorescein staining, meniscus height, and visual acuity. Safety measures included adverse events, slit lamp biomicroscopy, tonometry, blood pressure, and heart rate. Tolerability was also evaluated. This clinical study showed the effectiveness of Visomitin eye drops in the treatment of signs and symptoms of DES compared with placebo. The study showed that a 6-week course of TID topical instillation of Visomitin significantly improved the functional state of the cornea; Visomitin increased tear film stability and reduced corneal damage. Significant reduction of dry eye symptoms (such as dryness, burning, grittiness, and blurred vision) was also observed. Based on the results of this study, Visomitin is effective and safe for use in eye patients with DES for protection from corneal damage. Mitotech LLC.
Gaus, Wilhelm; Muche, Rainer
2013-05-01
Clinical studies provide formalised experience for evidence-based medicine (EBM). Many people consider a controlled randomised trial (CRT, identical to a randomised controlled trial RCT) to be the non-plus-ultra design. However, CRTs also have limitations. The problem is not randomisation itself but informed consent for randomisation and masking of therapies according to today's legal and ethical standards. We do not want to de-rate CRTs, but we would like to contribute to the discussion on clinical research methodology. Informed consent to a CRT and masking of therapies plainly select patients. The excellent internal validity of CRTs can be counterbalanced by poor external validity, because internal and external validity act as antagonists. In a CRT, patients may feel like guinea pigs, this can decrease compliance, cause protocol violations, reduce self-healing properties, suppress unspecific therapeutic effects and possibly even modify specific efficacy. A control group (comparative study) is most important for the degree of evidence achieved by a trial. Study control by detailed protocol and good clinical practice (controlled study) is second in importance and randomisation and masking is third (thus the sequence CRT instead of RCT). Controlled non-randomised trials are just as ambitious and detailed as CRTs. We recommend clinicians and biometricians to take high quality controlled non-randomised trials into consideration more often. They combine good internal and external validity, better suit daily medical practice, show better patient compliance and fewer protocol violations, deliver estimators unbiased by alienated patients, and perhaps provide a clearer explanation of the achieved success. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mehta, Sohan S.; Ganta, Lakshmi K.; Chauhan, Vikrant; Wu, Yixu; Singh, Sunil; Ann, Chia; Subramany, Lokesh; Higgins, Craig; Erenturk, Burcin; Srivastava, Ravi; Singh, Paramjit; Koh, Hui Peng; Cho, David
2015-03-01
Immersion based 20nm technology node and below becoming very challenging to chip designers, process and integration due to multiple patterning to integrate one design layer . Negative tone development (NTD) processes have been well accepted by industry experts for enabling technologies 20 nm and below. 193i double patterning is the technology solution for pitch down to 80 nm. This imposes tight control in critical dimension(CD) variation in double patterning where design patterns are decomposed in two different masks such as in litho-etch-litho etch (LELE). CD bimodality has been widely studied in LELE double patterning. A portion of CD tolerance budget is significantly consumed by variations in CD in double patterning. The objective of this work is to study the process variation challenges and resolution in the Negative Tone Develop Process for 20 nm and Below Technology Node. This paper describes the effect of dose slope on CD variation in negative tone develop LELE process. This effect becomes even more challenging with standalone NTD developer process due to q-time driven CD variation. We studied impact of different stacks with combination of binary and attenuated phase shift mask and estimated dose slope contribution individually from stack and mask type. Mask 3D simulation was carried out to understand theoretical aspect. In order to meet the minimum insulator requirement for the worst case on wafer the overlay and critical dimension uniformity (CDU) budget margins have slimmed. Besides the litho process and tool control using enhanced metrology feedback, the variation control has other dependencies too. Color balancing between the two masks in LELE is helpful in countering effects such as iso-dense bias, and pattern shifting. Dummy insertion and the improved decomposition techniques [2] using multiple lower priority constraints can help to a great extent. Innovative color aware routing techniques [3] can also help with achieving more uniform density and color balanced layouts.
Barnett, L A; Lewis, M; Mallen, C D; Peat, G
2017-12-04
Selection bias is a concern when designing cluster randomised controlled trials (c-RCT). Despite addressing potential issues at the design stage, bias cannot always be eradicated from a trial design. The application of bias analysis presents an important step forward in evaluating whether trial findings are credible. The aim of this paper is to give an example of the technique to quantify potential selection bias in c-RCTs. This analysis uses data from the Primary care Osteoarthritis Screening Trial (POST). The primary aim of this trial was to test whether screening for anxiety and depression, and providing appropriate care for patients consulting their GP with osteoarthritis would improve clinical outcomes. Quantitative bias analysis is a seldom-used technique that can quantify types of bias present in studies. Due to lack of information on the selection probability, probabilistic bias analysis with a range of triangular distributions was also used, applied at all three follow-up time points; 3, 6, and 12 months post consultation. A simple bias analysis was also applied to the study. Worse pain outcomes were observed among intervention participants than control participants (crude odds ratio at 3, 6, and 12 months: 1.30 (95% CI 1.01, 1.67), 1.39 (1.07, 1.80), and 1.17 (95% CI 0.90, 1.53), respectively). Probabilistic bias analysis suggested that the observed effect became statistically non-significant if the selection probability ratio was between 1.2 and 1.4. Selection probability ratios of > 1.8 were needed to mask a statistically significant benefit of the intervention. The use of probabilistic bias analysis in this c-RCT suggested that worse outcomes observed in the intervention arm could plausibly be attributed to selection bias. A very large degree of selection of bias was needed to mask a beneficial effect of intervention making this interpretation less plausible.
Na, J U; Han, S K; Choi, P C; Cho, J H; Shin, D H
2013-10-01
Different face mask designs can influence bag-valve-mask (BVM) ventilation performance during resuscitation. We compared a single-use, air-cushioned face mask (AM) with a reusable silicone face mask (SM) for quality of BVM ventilation on a manikin simulating cardiac arrest. Thirty-two physicians were recruited, and a prospective, randomized, crossover observational study was conducted after an American Heart Association-accredited basic life support provider course and standardized practice time were completed. Participants performed 12 cycles of BVM ventilation with both the AM and SM on a SmartMan lung simulator. Mean tidal volume was significantly higher in ventilations performed using the AM vs. the SM (548 ± 159 ml vs. 439 ± 163 ml, P < 0.01). In addition, the proportion of low-volume ventilation was significantly lower with the AM than the SM [6/12 (2-11) vs. 9/12 (5-12), P = 0.03]. Bag-valve-AM ventilation volume was not affected by the physical characteristics of the rescuers, except for sex. In contrast, bag-valve-SM ventilation volume was affected by most of the characteristics tested, including sex, height, weight, hand width, hand length, and grip power. The AM seems to be a more efficient face mask than the SM at delivering sufficient ventilation volumes. The performance of the AM did not seem to be associated with the physical characteristics of the rescuers, whereas that of the SM was affected by these factors. The SM may not be an appropriate face mask for performing one-person BVM ventilation during resuscitation for rescuers who are smaller in stature, have a smaller hand size, or have weaker grip power. © 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Yi, Eun-Jin; Kim, Ju-Young; Rhee, Yun-Seok; Kim, Su-Hyeon; Lee, Hyo-Joong; Park, Chun-Woong; Park, Eun-Seok
2014-05-15
The aim of the present study was to prepare the particulate taste-masking system to mask the bitter taste of sildenafil citrate (SC), a well-known phosphodiesterase-5 inhibitor used for erectile dysfunction (ED) and pulmonary artery hypertension (PAH). It was evaluated for the taste masking efficiency by the in vitro measurement using electronic tongue (e-tongue) system and the in vivo human panel sensory test. Microcapsules were prepared by microencapsulation with a gastro-soluble polymer, Eudragit(®) E100 (E100), using a spray drying technique at four different weight ratios (2:1, 1:1, 1:2, and 1:3). Characters of prepared microcapsules and the effect of polymer ratio on the taste masking were investigated. The particle morphology and the distribution of SC in microcapsules were observed by SEM-EDS and physical properties were evaluated by PXRD, Raman spectroscopy, and DSC. By drug dissolution studies at pH 1.2 buffer and DW, it was found that E100 was not able to alter the drug release in stomach. As the result of taste evaluation studies, there were a good correlation (R(2)=0.9867) between the weight ratio of polymer and the taste masking efficiency expressed in the distances on the PCA map of the e-tongue data, and a relevance of the e-tongue measurement with the result of sensory test. Copyright © 2014. Published by Elsevier B.V.
Extension of optical lithography by mask-litho integration with computational lithography
NASA Astrophysics Data System (ADS)
Takigawa, T.; Gronlund, K.; Wiley, J.
2010-05-01
Wafer lithography process windows can be enlarged by using source mask co-optimization (SMO). Recently, SMO including freeform wafer scanner illumination sources has been developed. Freeform sources are generated by a programmable illumination system using a micro-mirror array or by custom Diffractive Optical Elements (DOE). The combination of freeform sources and complex masks generated by SMO show increased wafer lithography process window and reduced MEEF. Full-chip mask optimization using source optimized by SMO can generate complex masks with small variable feature size sub-resolution assist features (SRAF). These complex masks create challenges for accurate mask pattern writing and low false-defect inspection. The accuracy of the small variable-sized mask SRAF patterns is degraded by short range mask process proximity effects. To address the accuracy needed for these complex masks, we developed a highly accurate mask process correction (MPC) capability. It is also difficult to achieve low false-defect inspections of complex masks with conventional mask defect inspection systems. A printability check system, Mask Lithography Manufacturability Check (M-LMC), is developed and integrated with 199-nm high NA inspection system, NPI. M-LMC successfully identifies printable defects from all of the masses of raw defect images collected during the inspection of a complex mask. Long range mask CD uniformity errors are compensated by scanner dose control. A mask CD uniformity error map obtained by mask metrology system is used as input data to the scanner. Using this method, wafer CD uniformity is improved. As reviewed above, mask-litho integration technology with computational lithography is becoming increasingly important.
NASA Astrophysics Data System (ADS)
Mita, Akifumi; Okamoto, Atsushi; Funakoshi, Hisatoshi
2004-06-01
We have proposed an all-optical authentic memory with the two-wave encryption method. In the recording process, the image data are encrypted to a white noise by the random phase masks added on the input beam with the image data and the reference beam. Only reading beam with the phase-conjugated distribution of the reference beam can decrypt the encrypted data. If the encrypted data are read out with an incorrect phase distribution, the output data are transformed into a white noise. Moreover, during read out, reconstructions of the encrypted data interfere destructively resulting in zero intensity. Therefore our memory has a merit that we can detect unlawful accesses easily by measuring the output beam intensity. In our encryption method, the random phase mask on the input plane plays important roles in transforming the input image into a white noise and prohibiting to decrypt a white noise to the input image by the blind deconvolution method. Without this mask, when unauthorized users observe the output beam by using CCD in the readout with the plane wave, the completely same intensity distribution as that of Fourier transform of the input image is obtained. Therefore the encrypted image will be decrypted easily by using the blind deconvolution method. However in using this mask, even if unauthorized users observe the output beam using the same method, the encrypted image cannot be decrypted because the observed intensity distribution is dispersed at random by this mask. Thus it can be said the robustness is increased by this mask. In this report, we compare two correlation coefficients, which represents the degree of a white noise of the output image, between the output image and the input image in using this mask or not. We show that the robustness of this encryption method is increased as the correlation coefficient is improved from 0.3 to 0.1 by using this mask.
Gijón-Conde, Teresa; Graciani, Auxiliadora; López-García, Esther; Guallar-Castillón, Pilar; García-Esquinas, Esther; Rodríguez-Artalejo, Fernando; Banegas, José R
2017-06-01
Blood pressure (BP) variability and nocturnal decline in blood pressure are associated with cardiovascular outcomes. However, little is known about whether these indexes are associated with white-coat and masked hypertension. We performed a cross-sectional analysis of 1047 community-dwelling individuals aged ⩾60 years in Spain in 2012. Three observer-measured home BPs and 24-h ambulatory blood pressure monitoring (ABPM) were performed under standardized conditions. BP variability was defined as BP s.d. and coefficient of variation. Differences in BP variability and nocturnal BP decrease between groups were adjusted for sociodemographic and clinical covariates using generalized linear models. Of the cohort, 21.7% had white-coat hypertension, 7.0% had masked hypertension, 21.4% had sustained hypertension, and 49.9% were normotensive. Twenty-four hour, daytime and night-time systolic BP s.d. and coefficients of variation were significantly higher in subjects with white-coat hypertension than those with normotension (P<0.05) and were similar to subjects with sustained hypertension. In untreated subjects, 24-h but not daytime or night-time BP variability indexes were significantly higher in subjects with white-coat hypertension than in those with normotension (P<0.05). Percentage decrease in nocturnal systolic and diastolic BP was greatest in the white-coat hypertension group and lowest in the masked hypertension group in all patients and untreated patients (P<0.05). Lack of nocturnal decline in systolic blood pressure was observed in 70.2% of subjects with normotension, 57.8% of subjects with white-coat hypertension, 78.1% of subjects with masked hypertension, and 72.2% of subjects with sustained hypertension (P<0.001). In conclusion, 24-h BP variability was higher in subjects with white-coat hypertension and blunted nocturnal BP decrease was observed more frequently in subjects with masked hypertension. These findings may help to explain the reports of increased cardiovascular risk in patients with white-coat hypertension and poor prognosis in those with masked hypertension, highlighting the importance of ABPM.
VizieR Online Data Catalog: Radial velocities of galaxies in A523 field (Girardi+, 2016)
NASA Astrophysics Data System (ADS)
Girardi, M.; Boschin, W.; Gastaldello, F.; Giovannini, G.; Govoni, F.; Murgia, M.; Barrena, R.; Ettori, S.; Trasatti, M.; Vacca, V.
2016-09-01
Multi-object spectroscopic observations of A523 were carried out at the TNG in 2012 December and 2014 January. We used the instrument DOLORES in MOS mode with the LR-B Grism. In summary, we observed six MOS masks for a total of 210 slits. The total exposure time was 3600s for three masks, 5400s for two masks and 7200s for the last one. Our photometric observations were carried out with the Wide Field Camera (WFC), mounted at the prime focus of the 2.5-m INT telescope. We observed A523 in g, r and i Sloan-Gunn filters in photometric conditions and a seeing of ~1.4arcsec. (1 data file).
Effects of subliminally presented auditory suggestions of itching on scratching behavior.
Mitchell, C W
1995-02-01
This study investigated effects of masked verbal suggestions of itching, utilizing a design closely analogous to commercially available subliminal audiotapes. Students participated in 1 of 3 groups (n = 21): an experimental group listened to an audiotape with music masking suggestions of itching, Control Group 1 listened to an audiotape with music only, and Control Group 2 listened to suggestions of itching presented supraliminally. Dependent variables included both behavioral and self-report measures of itching. There was no evidence of influence from subliminal suggestion; however, results assessing the influence of supraliminally presented suggestions were mixed for self-report and behavioral measures.
Masking in three pinnipeds: underwater, low-frequency critical ratios.
Southall, B L; Schusterman, R J; Kastak, D
2000-09-01
Behavioral techniques were used to determine underwater masked hearing thresholds for a northern elephant seal (Mirounga angustirostris), a harbor seal (Phoca vitulina), and a California sea lion (Zalophus californianus). Octave-band white noise maskers were centered at five test frequencies ranging from 200 to 2500 Hz; a slightly wider noise band was used for testing at 100 Hz. Critical ratios were calculated at one masking noise level for each test frequency. Above 200 Hz, critical ratios increased with frequency. This pattern is similar to that observed in most animals tested, and indicates that these pinnipeds lack specializations for detecting low-frequency tonal sounds in noise. However, the individual pinnipeds in this study, particularly the northern elephant seal, detected signals at relatively low signal-to-noise ratios. These results provide a means of estimating zones of auditory masking for pinnipeds exposed to anthropogenic noise sources.
Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey
2017-08-01
The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Upadhyaya, Mihir; Jindal, Vibhu; Basavalingappa, Adarsh
The availability of defect-free masks is considered to be a critical issue for enabling extreme ultraviolet lithography (EUVL) as the next generation technology. Since completely defect-free masks will be hard to achieve, it is essential to have a good understanding of the printability of the native EUV mask defects. In this work, we performed a systematic study of native mask defects to understand the defect printability caused by them. The multilayer growth over native substrate mask blank defects was correlated to the multilayer growth over regular-shaped defects having similar profiles in terms of their width and height. To model themore » multilayer growth over the defects, a novel level-set multilayer growth model was used that took into account the tool deposition conditions of the Veeco Nexus ion beam deposition tool. The same tool was used for performing the actual deposition of the multilayer stack over the characterized native defects, thus ensuring a fair comparison between the actual multilayer growth over native defects, and modeled multilayer growth over regular-shaped defects. Further, the printability of the characterized native defects was studied with the SEMATECH-Berkeley Actinic Inspection Tool (AIT), an EUV mask-imaging microscope at Lawrence Berkeley National Laboratory (LBNL). Printability of the modeled regular-shaped defects, which were propagated up the multilayer stack using level-set growth model was studied using defect printability simulations implementing the waveguide algorithm. Good comparison was observed between AIT and the simulation results, thus demonstrating that multilayer growth over a defect is primarily a function of a defect’s width and height, irrespective of its shape. This would allow us to predict printability of the arbitrarily-shaped native EUV mask defects in a systematic and robust manner.« less
Large-area soft x-ray projection lithography using multilayer mirrors structured by RIE
NASA Astrophysics Data System (ADS)
Rahn, Steffen; Kloidt, Andreas; Kleineberg, Ulf; Schmiedeskamp, Bernt; Kadel, Klaus; Schomburg, Werner K.; Hormes, F. J.; Heinzmann, Ulrich
1993-01-01
SXPL (soft X-ray projection lithography) is one of the most promising applications of X-ray reflecting optics using multilayer mirrors. Within our collaboration, such multilayer mirrors were fabricated, characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors were produced by electron beam evaporation in UHV under thermal treatment with an in-situ X-ray controlled thickness in the region of 2d equals 14 nm. The reflectivities measured at normal incidence reached up to 54%. Various surface analysis techniques have been applied in order to characterize and optimize the X-ray mirrors. The multilayers were patterned by reactive ion etching (RIE) with CF(subscript 4), using a photoresist as the etch mask, thus producing X-ray reflection masks. The masks were tested in the synchrotron radiation laboratory of the electron accelerator ELSA at the Physikalisches Institut of Bonn University. A double crystal X-ray monochromator was modified so as to allow about 0.5 cm(superscript 2) of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto the resist (Hoechst AZ PF 514), which was mounted at an average distance of about 7 mm. In the first test-experiments, structure sizes down to 8 micrometers were nicely reproduced over the whole of the exposed area. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.
Noh, Heil; Lee, Dong-Hee
2012-09-01
To investigate the electric-acoustic interactions within the inferior colliculus of guinea pigs and to observe how central masking appears in invasive neural recordings of the inferior colliculus (IC). A platinum-iridium wire was inserted to scala tympani through cochleostomy with a depth no greater than 1 mm for intracochlear stimulation of electric pulse train. A 5 mm 100 µm, single-shank, thin-film, penetrating recording probe was inserted perpendicularly to the surface of the IC in the coronal plane at an angle of 30-40° off the parasagittal plane with a depth of 2.0-2.5 mm. The peripheral and central masking effects were compared using electric pulse trains to the left ear and acoustic noise to the left ear (ipsilateral) and to the right ear (contralateral). Binaural acoustic stimuli were presented with different time delays and compared with combined electric and acoustic stimuli. The averaged evoked potentials and total spike numbers were measured using thin-film electrodes inserted into the central nucleus of the IC. Ipsilateral noise had more obvious effects on the electric response than did contralateral noise. Contralateral noise decreased slightly the response amplitude to the electric pulse train stimuli. Immediately after the onset of acoustic noise, the response pattern changed transiently with shorter response intervals. The effects of contralateral noise were evident at the beginning of the continuous noise. The total spike number decreased when the binaural stimuli reached the IC most simultaneously. These results suggest that central masking is quite different from peripheral masking and occurs within the binaural auditory system, and this study showed that the effect of masking could be observed in the IC recording. These effects are more evident and consistent with the psychophysical data from spike number analyses than with the previously reported gross potential data.
A masking level difference due to harmonicity.
Treurniet, W C; Boucher, D R
2001-01-01
The role of harmonicity in masking was studied by comparing the effect of harmonic and inharmonic maskers on the masked thresholds of noise probes using a three-alternative, forced-choice method. Harmonic maskers were created by selecting sets of partials from a harmonic series with an 88-Hz fundamental and 45 consecutive partials. Inharmonic maskers differed in that the partial frequencies were perturbed to nearby values that were not integer multiples of the fundamental frequency. Average simultaneous-masked thresholds were as much as 10 dB lower with the harmonic masker than with the inharmonic masker, and this difference was unaffected by masker level. It was reduced or eliminated when the harmonic partials were separated by more than 176 Hz, suggesting that the effect is related to the extent to which the harmonics are resolved by auditory filters. The threshold difference was not observed in a forward-masking experiment. Finally, an across-channel mechanism was implicated when the threshold difference was found between a harmonic masker flanked by harmonic bands and a harmonic masker flanked by inharmonic bands. A model developed to explain the observed difference recognizes that an auditory filter output envelope is modulated when the filter passes two or more sinusoids, and that the modulation rate depends on the differences among the input frequencies. For a harmonic masker, the frequency differences of adjacent partials are identical, and all auditory filters have the same dominant modulation rate. For an inharmonic masker, however, the frequency differences are not constant and the envelope modulation rate varies across filters. The model proposes that a lower variability facilitates detection of a probe-induced change in the variability, thus accounting for the masked threshold difference. The model was supported by significantly improved predictions of observed thresholds when the predictor variables included envelope modulation rate variance measured using simulated auditory filters.
NASA Astrophysics Data System (ADS)
Lee, Hyemi; Jeong, Goomin; Seo, Kangjun; Kim, Sangchul; kim, changreol
2008-05-01
Since mask design rule is smaller and smaller, Defects become one of the issues dropping the mask yield. Furthermore controlled defect size become smaller while masks are manufactured. According to ITRS roadmap on 2007, controlled defect size is 46nm in 57nm node and 36nm in 45nm node on a mask. However the machine development is delayed in contrast with the speed of the photolithography development. Generally mask manufacturing process is divided into 3 parts. First part is patterning on a mask and second part is inspecting the pattern and repairing the defect on the mask. At that time, inspection tools of transmitted light type are normally used and are the most trustful as progressive type in the developed inspection tools until now. Final part is shipping the mask after the qualifying the issue points and weak points. Issue points on a mask are qualified by using the AIMS (Aerial image measurement system). But this system is including the inherent error possibility, which is AIMS measures the issue points based on the inspection results. It means defects printed on a wafer are over the specific size detected by inspection tools and the inspection tool detects the almost defects. Even though there are no tools to detect the 46nm and 36nm defects suggested by ITRS roadmap, this assumption is applied to manufacturing the 57nm and 45nm device. So we make the programmed defect mask consisted with various defect type such as spot, clear extension, dark extension and CD variation on L/S(line and space), C/H(contact hole) and Active pattern in 55nm and 45nm node. And the programmed defect mask was inspected by using the inspection tool of transmitted light type and was measured by using AIMS 45-193i. Then the marginal defects were compared between the inspection tool and AIMS. Accordingly we could verify whether defect size is proper or not, which was suggested to be controlled on a mask by ITRS roadmap. Also this result could suggest appropriate inspection tools for next generation device among the inspection tools of transmitted light type, reflected light type and aerial image type.
Li, Jia; Lam, Edmund Y
2014-04-21
Mask topography effects need to be taken into consideration for a more accurate solution of source mask optimization (SMO) in advanced optical lithography. However, rigorous 3D mask models generally involve intensive computation and conventional SMO fails to manipulate the mask-induced undesired phase errors that degrade the usable depth of focus (uDOF) and process yield. In this work, an optimization approach incorporating pupil wavefront aberrations into SMO procedure is developed as an alternative to maximize the uDOF. We first design the pupil wavefront function by adding primary and secondary spherical aberrations through the coefficients of the Zernike polynomials, and then apply the conjugate gradient method to achieve an optimal source-mask pair under the condition of aberrated pupil. We also use a statistical model to determine the Zernike coefficients for the phase control and adjustment. Rigorous simulations of thick masks show that this approach provides compensation for mask topography effects by improving the pattern fidelity and increasing uDOF.
2013-01-01
Background Tuberculosis infection control (TBIC) is rarely implemented in the health facilities in resource limited settings. Understanding the reasons for low level of implementation is critical. The study aim was to assess TBIC practices and barriers to implementation in two districts in Uganda. Methods We conducted a cross-sectional study in 51 health facilities in districts of Mukono and Wakiso. The study included: a facility survey, observations of practices and eight focus group discussions with health workers. Results Quantitative: Only 16 facilities (31%) had a TBIC plan. Five facilities (10%) were screening patients for cough. Two facilities (4%) reported providing masks to patients with cough. Ventilation in the waiting areas was inadequate for TBIC in 43% (22/51) of the facilities. No facility possessed N95 particulate respirators. Qualitative: Barriers that hamper implementation of TBIC elicited included: under-staffing, lack of space for patient separation, lack of funds to purchase masks, and health workers not appreciating the importance of TBIC. Conclusion TBIC measures were not implemented in health facilities in the two Ugandan districts where the survey was done. Health system factors like lack of staff, space and funds are barriers to implement TBIC. Effective implementation of TBIC measures occurs when the fundamental health system building blocks -governance and stewardship, financing, infrastructure, procurement and supply chain management are in place and functioning appropriately. PMID:23915376
Buregyeya, Esther; Nuwaha, Fred; Verver, Suzanne; Criel, Bart; Colebunders, Robert; Wanyenze, Rhoda; Kalyango, Joan N; Katamba, Achilles; Mitchell, Ellen Mh
2013-08-01
Tuberculosis infection control (TBIC) is rarely implemented in the health facilities in resource limited settings. Understanding the reasons for low level of implementation is critical. The study aim was to assess TBIC practices and barriers to implementation in two districts in Uganda. We conducted a cross-sectional study in 51 health facilities in districts of Mukono and Wakiso. The study included: a facility survey, observations of practices and eight focus group discussions with health workers. Quantitative: Only 16 facilities (31%) had a TBIC plan. Five facilities (10%) were screening patients for cough. Two facilities (4%) reported providing masks to patients with cough. Ventilation in the waiting areas was inadequate for TBIC in 43% (22/51) of the facilities. No facility possessed N95 particulate respirators. Qualitative: Barriers that hamper implementation of TBIC elicited included: under-staffing, lack of space for patient separation, lack of funds to purchase masks, and health workers not appreciating the importance of TBIC. TBIC measures were not implemented in health facilities in the two Ugandan districts where the survey was done. Health system factors like lack of staff, space and funds are barriers to implement TBIC. Effective implementation of TBIC measures occurs when the fundamental health system building blocks--governance and stewardship, financing, infrastructure, procurement and supply chain management are in place and functioning appropriately.
Gorostidi, Manuel; Sarafidis, Pantelis A; de la Sierra, Alejandro; Segura, Julian; de la Cruz, Juan J; Banegas, Jose R; Ruilope, Luis M
2013-08-01
Previous studies have examined control rates of office blood pressure (BP) in chronic kidney disease (CKD). However, recent evidence suggests major discrepancies between office and 24-hour BP values in hypertensive populations. This study examined concordance/discordance between office- and ambulatory-based BP control in a large cohort of patients with CKD. Cross-sectional. 5,693 hypertensive individuals with CKD stages 1-5 from the Spanish ABPM (ambulatory BP monitoring) Registry. Thresholds of 140/90 and 130/80 mm Hg for office BP and 24-hour ambulatory BP, respectively. Age, sex, body mass index, waist circumference, hypertension duration, kidney measures, diabetes, dyslipidemia, target-organ damage, and cardiovascular comorbid conditions. Misclassification of BP control as "white-coat" hypertension (office BP ≥140/90 mm Hg, 24-hour BP <130/80 mm Hg) or masked hypertension (office BP <140/90 mm Hg, 24-hour BP ≥130/80 mm Hg). Standardized office-based BP and 24-hour ABPM. Mean age was 61.0 ± 13.9 (SD) years and 52.6% were men. The proportion with white-coat hypertension was 28.8% (36.8% of patients with office BP ≥140/90 mm Hg) and that of masked hypertension was 7.0% (but 32.1% of patients with office BP <140/90 mm Hg). Female sex, aging, obesity, and target-organ damage were associated with white-coat hypertension; aging and obesity were associated with masked hypertension. Only 21.7% and 8.1% of the CKD population had office BP <140/90 and <130/80 mm Hg, respectively. In contrast, 43.5% of individuals had average 24-hour BP <130/80 mm Hg. Cross-sectional design, longitudinal associations cannot be established. Misclassification of BP control at the office was observed in 1 of 3 hypertensive patients with CKD. Ambulatory-based control rates were far better than office-based rates. Nevertheless, the burden of uncontrolled ambulatory BP and misclassification of BP control at the office constitutes a call for wider use of ABPM to evaluate the success of hypertension treatment in patients with CKD. Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
ArF halftone PSM cleaning process optimization for next-generation lithography
NASA Astrophysics Data System (ADS)
Son, Yong-Seok; Jeong, Seong-Ho; Kim, Jeong-Bae; Kim, Hong-Seok
2000-07-01
ArF lithography which is expected for the next generation optical lithography is adapted for 0.13 micrometers design-rule and beyond. ArF half-tone phase shift mask (HT PSM) will be applied as 1st generation of ArF lithography. Also ArF PSM cleaning demands by means of tighter controls related to phase angle, transmittance and contamination on the masks. Phase angle on ArF HT PSM should be controlled within at least +/- 3 degree and transmittance controlled within at least +/- 3 percent after cleaning process and pelliclization. In the cleaning process of HT PSM, requires not only the remove the particle on mask, but also control to half-tone material for metamorphosis. Contamination defects on the Qz of half tone type PSM is not easy to remove on the photomask surface. New technology and methods of cleaning will be developed in near future, but we try to get out for limit contamination on the mask, without variation of phase angle and transmittance after cleaning process.
Feasibility of aerosol drug delivery to sleeping infants: a prospective observational study.
Amirav, Israel; Newhouse, Michael T; Luder, Anthony; Halamish, Asaf; Omar, Hamza; Gorenberg, Miguel
2014-03-26
Delivery of inhaled medications to infants is usually very demanding and is often associated with crying and mask rejection. It has been suggested that aerosol administration during sleep may be an attractive alternative. Previous studies in sleeping children were disappointing as most of the children awoke and rejected the treatment. The SootherMask (SM) is a new, gentle and innovative approach for delivering inhaled medication to infants and toddlers. The present pilot study describes the feasibility of administering inhaled medications during sleep using the SM. Prospective observational study. Out patients. 13 sleeping infants with recurrent wheezing who regularly used pacifiers and were <12 months old. Participants inhaled technetium99mDTPA-labelled normal saline aerosol delivered via a Respimat Soft Mist Inhaler (SMI) (Boehringer-Ingelheim, Germany) and SM + InspiraChamber (IC; InspiRx Inc, New Jersey, USA). The two major outcomes were the acceptability of the treatment and the lung deposition (per cent of emitted dose). All infants who fulfilled the inclusion criteria successfully received the SM treatment during sleep without difficulty. Mean lung deposition (±SD) averaged 1.6±0.5% in the right lung. This study demonstrated that the combination of Respimat, IC and SM was able to administer aerosol therapy to all the sleeping infants who were regular pacifier users with good lung deposition. Administration of aerosols during sleep is advantageous since all the sleeping children accepted the mask and ensuing aerosol therapy under these conditions, in contrast to previous studies in which there was frequent mask rejection using currently available devices. NCT01120938.
My Other Half Manifested in Mask-Making
ERIC Educational Resources Information Center
Abel, Xanthippi
2010-01-01
Every fall season, each grade level of Rowland Hall St. Mark's Lower School in Salt Lake City, Utah, completes a mask-making project to be featured in a schoolwide parade. This sparked an opportunity to incorporate the fourth-grade unit of realistic and observational drawing with mask making. In this article, the author describes how her students…
Tang, Julian W.; Liebner, Thomas J.; Craven, Brent A.; Settles, Gary S.
2009-01-01
Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask). PMID:19815575
Tang, Julian W; Liebner, Thomas J; Craven, Brent A; Settles, Gary S
2009-12-06
Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask).
Getting the cocktail party started: masking effects in speech perception
Evans, S; McGettigan, C; Agnew, ZK; Rosen, S; Scott, SK
2016-01-01
Spoken conversations typically take place in noisy environments and different kinds of masking sounds place differing demands on cognitive resources. Previous studies, examining the modulation of neural activity associated with the properties of competing sounds, have shown that additional speech streams engage the superior temporal gyrus. However, the absence of a condition in which target speech was heard without additional masking made it difficult to identify brain networks specific to masking and to ascertain the extent to which competing speech was processed equivalently to target speech. In this study, we scanned young healthy adults with continuous functional Magnetic Resonance Imaging (fMRI), whilst they listened to stories masked by sounds that differed in their similarity to speech. We show that auditory attention and control networks are activated during attentive listening to masked speech in the absence of an overt behavioural task. We demonstrate that competing speech is processed predominantly in the left hemisphere within the same pathway as target speech but is not treated equivalently within that stream, and that individuals who perform better in speech in noise tasks activate the left mid-posterior superior temporal gyrus more. Finally, we identify neural responses associated with the onset of sounds in the auditory environment, activity was found within right lateralised frontal regions consistent with a phasic alerting response. Taken together, these results provide a comprehensive account of the neural processes involved in listening in noise. PMID:26696297
Gender Differences in Neural Responses to Perceptually Invisible Fearful Face—An ERP Study
Lee, Seung A.; Kim, Chai-Youn; Shim, Miseon; Lee, Seung-Hwan
2017-01-01
Women tend to respond to emotional stimuli differently from men. This study aimed at investigating whether neural responses to perceptually “invisible” emotional stimuli differ between men and women by exploiting event-related potential (ERP). Forty healthy participants (21 women) were recruited for the main experiment. A control experiment was conducted by excluding nine (7 women) participants from the main experiment and replacing them with additional ten (6 women) participants (total 41 participants) where Beck's Anxiety Inventory (BAI) and Beck's Depression Inventory (BDI) scores were controlled. Using the visual backward masking paradigm, either a fearful or a neutral face stimulus was presented in varied durations (subthreshold, near-threshold, or suprathreshold) followed by a mask. Participants performed a two-alternative forced choice (2-AFC) emotion discrimination task on each face. Behavioral analysis showed that participants were unaware of masked stimuli of which duration was the shortest and, therefore, processed at subthreshold. Nevertheless, women showed significantly larger response in P100 amplitude to subthreshold fearful faces than men. This result remained consistent in the control experiment. Our findings indicate gender-differences in neural response to subthreshold emotional face, which is reflected in the early processing stage. PMID:28184189
Across-channel interference in intensity discrimination: The role of practice and listening strategy
Buss, Emily
2008-01-01
Pure tone intensity discrimination thresholds can be elevated by the introduction of remote maskers with roved level. This effect is on the order of 10 dB [10log(ΔI/I)] in some conditions and can be demonstrated under conditions of little or no energetic masking. The current study examined the effect of practice and observer strategy on this phenomenon. Experiment 1 included observers who had no formal experience with intensity discrimination and provided training over six hours on a single masked intensity discrimination task to assess learning effects. Thresholds fell with practice for most observers, with significant improvements in 6 out of 8 cases. Despite these improvements significant masking remained in all cases. The second experiment assessed trial-by-trial effects of roved masker level. Conditional probability of a ‘signal-present’ response as a function of the rove value assigned to each of the two masker tones indicates fundamental differences among observers’ processing strategies, even after six hours of practice. The variability in error patterns across practiced listeners suggests that observers approach the task differently, though this variability does not appear to be related to sensitivity. PMID:18177156
Effect of Three Different Core Materials on Masking Ability of a Zirconia Ceramic.
Tabatabaian, Farhad; Masoomi, Faeze; Namdari, Mahshid; Mahshid, Minoo
2016-09-01
Masking ability of a restorative material plays a role in hiding colored substructures; however, the masking ability of zirconia ceramic (ZRC) has not yet been clearly understood in zirconia-based restorations. This study evaluated the effect of three different core materials on masking ability of a ZRC. Ten zirconia disc samples, 0.5mm in thickness and 10mm in diameter, were fabricated. A white (W) substrate (control) and three substrates of nickel-chromium alloy (NCA), non-precious gold alloy (NPGA), and ZRC were prepared. The zirconia discs were placed on the four types of substrates for spectrophotometry. The L*, a*, and b* values of the specimens were measured by a spectrophotometer and color change (ΔE) values were calculated to determine color differences between the test and control groups and were then compared with the perceptual threshold. Randomized block ANOVA and Bonferroni test analyzed the data. A significance level of 0.05 was considered. The mean and standard deviation values of ΔE for NCA, NPGA, and ZRC groups were 10.26±2.43, 9.45±1.74, and 6.70±1.91 units, respectively. Significant differences were found in the ΔE values between ZRC and the other two experimental groups (NCA and NPGA; P<0.0001 and P=0.001, respectively). The ΔE values for the groups were more than the predetermined perceptual threshold. Within the limitations of this study, it was concluded that the tested ZRC could not well mask the examined core materials.
Krüger, Benjamin; Büchner, Andreas; Nogueira, Waldo
2017-09-01
Ipsilateral electric-acoustic stimulation (EAS) is becoming increasingly important in cochlear implant (CI) treatment. Improvements in electrode designs and surgical techniques have contributed to improved hearing preservation during implantation. Consequently, CI implantation criteria have been expanded toward people with significant residual low-frequency hearing, who may benefit from the combined use of both the electric and acoustic stimulation in the same ear. However, only few studies have investigated the mutual interaction between electric and acoustic stimulation modalities. This work characterizes the interaction between both stimulation modalities using psychophysical masking experiments and cone beam computer tomography (CBCT). Two psychophysical experiments for electric and acoustic masking were performed to measure the hearing threshold elevation of a probe stimulus in the presence of a masker stimulus. For electric masking, the probe stimulus was an acoustic tone while the masker stimulus was an electric pulse train. For acoustic masking, the probe stimulus was an electric pulse train and the masker stimulus was an acoustic tone. Five EAS users, implanted with a CI and ipsilateral residual low-frequency hearing, participated in the study. Masking was determined at different electrodes and different acoustic frequencies. CBCT scans were used to determine the individual place-pitch frequencies of the intracochlear electrode contacts by using the Stakhovskaya place-to-frequency transformation. This allows the characterization of masking as a function of the difference between electric and acoustic stimulation sites, which we term the electric-acoustic frequency difference (EAFD). The results demonstrate a significant elevation of detection thresholds for both experiments. In electric masking, acoustic-tone thresholds increased exponentially with decreasing EAFD. In contrast, for the acoustic masking experiment, threshold elevations were present regardless of the tested EAFDs. Based on the present findings, we conclude that there is an asymmetry between the electric and the acoustic masker modalities. These observations have implications for the design and fitting of EAS sound-coding strategies. Copyright © 2017 Elsevier B.V. All rights reserved.
Associative and repetition priming with the repeated masked prime technique: no priming found.
Avons, S E; Russo, Riccardo; Cinel, Caterina; Verolini, Veronica; Glynn, Kevin; McDonald, Rebecca; Cameron, Marie
2009-01-01
Wentura and Frings (2005) reported evidence of subliminal categorical priming on a lexical decision task, using a new method of visual masking in which the prime string consisted of the prime word flanked by random consonants and random letter masks alternated with the prime string on successive refresh cycles. We investigated associative and repetition priming on lexical decision, using the same method of visual masking. Three experiments failed to show any evidence of associative priming, (1) when the prime string was fixed at 10 characters (three to six flanking letters) and (2) when the number of flanking letters were reduced or absent. In all cases, prime detection was at chance level. Strong associative priming was observed with visible unmasked primes, but the addition of flanking letters restricted priming even though prime detection was still high. With repetition priming, no priming effects were found with the repeated masked technique, and prime detection was poor but just above chance levels. We conclude that with repeated masked primes, there is effective visual masking but that associative priming and repetition priming do not occur with experiment-unique prime-target pairs. Explanations for this apparent discrepancy across priming paradigms are discussed. The priming stimuli and prime-target pairs used in this study may be downloaded as supplemental materials from mc.psychonomic-journals.org/content/supplemental.
Nasal vs Oronasal CPAP for OSA Treatment: A Meta-Analysis.
Andrade, Rafaela G S; Viana, Fernanda M; Nascimento, Juliana A; Drager, Luciano F; Moffa, Adriano; Brunoni, André R; Genta, Pedro R; Lorenzi-Filho, Geraldo
2018-03-01
Nasal CPAP is the "gold standard" treatment for OSA. However, oronasal masks are frequently used in clinical practice. The aim of this study was to perform a meta-analysis of all randomized and nonrandomized trials that compared nasal vs oronasal masks on CPAP level, residual apnea-hypopnea index (AHI), and CPAP adherence to treat OSA. The Cochrane Central Register of Controlled Trials, Medline, and Web of Science were searched for relevant studies in any language with the following terms: "sleep apnea" and "CPAP" or "sleep apnea" and "oronasal mask" or "OSA" and "oronasal CPAP" or "oronasal mask" and "adherence." Studies on CPAP treatment for OSA were included, based on the following criteria: (1) original article; (2) randomized or nonrandomized trials; and (3) comparison between nasal and oronasal CPAP including pressure level, and/or residual AHI, and/or CPAP adherence. We identified five randomized and eight nonrandomized trials (4,563 patients) that reported CPAP level and/or residual AHI and/or CPAP adherence. Overall, the random-effects meta-analysis revealed that as compared with nasal, oronasal masks were associated with a significantly higher CPAP level (Hedges' g, -0.59; 95% CI, -0.82 to -0.37; P < .001) (on average, +1.5 cm H 2 O), higher residual AHI (Hedges' g, -0.34; 95% CI, -0.52 to -0.17; P < .001) (+2.8 events/h), and a poorer adherence (Hedges' g, 0.50; 95% CI, 0.21-0.79; P = .001) (-48 min/night). Oronasal masks are associated with a higher CPAP level, higher residual AHI, and poorer adherence than nasal masks. PROSPERO database; No.: CRD42017064584; URL: https://www.crd.york.ac.uk/prospero/. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Lateralization of kin recognition signals in the human face
Dal Martello, Maria F.; Maloney, Laurence T.
2010-01-01
When human subjects view photographs of faces, their judgments of identity, gender, emotion, age, and attractiveness depend more on one side of the face than the other. We report an experiment testing whether allocentric kin recognition (the ability to judge the degree of kinship between individuals other than the observer) is also lateralized. One hundred and twenty-four observers judged whether or not pairs of children were biological siblings by looking at photographs of their faces. In three separate conditions, (1) the right hemi-face was masked, (2) the left hemi-face was masked, or (3) the face was fully visible. The d′ measures for the masked left hemi-face and masked right hemi-face were 1.024 and 1.004, respectively (no significant difference), and the d′ measure for the unmasked face was 1.079, not significantly greater than that for either of the masked conditions. We conclude, first, that there is no superiority of one or the other side of the observed face in kin recognition, second, that the information present in the left and right hemi-faces relevant to recognizing kin is completely redundant, and last that symmetry cues are not used for kin recognition. PMID:20884584
Modeling and Observations of Phase-Mask Trapezoidal Profiles with Grating-Fiber Image Reproduction
NASA Technical Reports Server (NTRS)
Lyons, Donald R.; Lindesay, James V.; Lee, Hyung R.; Ndlela, Zolili U.; Thompso, Erica J.
2000-01-01
We report on an investigation of the trapezoidal design and fabrication defects in phase masks used to produce Bragg reflection gratings in optical fibers. We used a direct visualization technique to examine the nonuniformity of the interference patterns generated by several phase masks. Fringe patterns from the phase masks are compared with the analogous patterns resulting from two-beam interference. Atomic force microscope imaging of the actual phase gratings that give rise to anomalous fringe patterns is used to determine input parameters for a general theoretical model. Phase masks with pitches of 0.566 and 1.059 microns are modeled and investigated.
Redesign of an Open-System Oxygen Face Mask With Mainstream Capnometer for Children.
Napolitano, Natalie; Nishisaki, Akira; Buffman, Hayley S; Leffelman, Jessica; Maltese, Matthew R; Nadkarni, Vinay M
2017-01-01
Partial pressure of end-tidal carbon dioxide (P ETCO 2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring P ETCO 2 in children without a tracheal tube is challenging. To improve P ETCO 2 measurement accuracy in a commercially available mask with a mainstream CO 2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup. Two sizes of redesigned face masks (small for 7-20 kg, medium for 10-40 kg) were evaluated. Initial bench testing used a simulator modeling a spontaneously breathing infant and child with a natural airway. An infant/child manikin head was connected to the breathing lung simulator. A mass flow controller provided expiratory CO 2 . Mask fit was then evaluated on healthy human subjects to identify anatomical features associated with good fit, defined as square shape capnography waveform during expiration. A 3-dimensional digital scan was used to quantify anatomical features. The gaps between face mask rims and facial surface were manually measured. Bench testing revealed a P ETCO 2 difference of 3.4 ± 1.5 mm Hg between a measured P ETCO 2 by the redesigned mask and CO 2 concentration at trachea, as compared with 6.7 ± 6.2 mm Hg between P ETCO 2 measured by nasal cannula and trachea (P < .001). In the human mask fit study, 35 children (13 ± 4 kg) with the small mask and 38 (24 ± 8 kg) with the medium mask were evaluated. Capnography tracing was successfully obtained in 86% of the small and 100% of the medium masks. In children with small-size masks, the gap between the face mask rim and the child's face was not statistically different among those with good mask fit and without (1.0 ± 1.5 mm vs 1.4 ± 1.9 mm, P = .73). P ETCO 2 measurement by a redesigned open-system face mask with a mainstream CO 2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit and accurate capnography tracings in the majority of infants and children. Copyright © 2017 by Daedalus Enterprises.
How color, regularity, and good Gestalt determine backward masking.
Sayim, Bilge; Manassi, Mauro; Herzog, Michael
2014-06-18
The strength of visual backward masking depends on the stimulus onset asynchrony (SOA) between target and mask. Recently, it was shown that the conjoint spatial layout of target and mask is as crucial as SOA. Particularly, masking strength depends on whether target and mask group with each other. The same is true in crowding where the global spatial layout of the flankers and target-flanker grouping determine crowding strength. Here, we presented a vernier target followed by different flanker configurations at varying SOAs. Similar to crowding, masking of a red vernier target was strongly reduced for arrays of 10 green compared with 10 red flanking lines. Unlike crowding, single green lines flanking the red vernier showed strong masking. Irregularly arranged flanking lines yielded stronger masking than did regularly arranged lines, again similar to crowding. While cuboid flankers reduced crowding compared with single lines, this was not the case in masking. We propose that, first, masking is reduced when the flankers are part of a larger spatial structure. Second, spatial factors counteract color differences between the target and the flankers. Third, complex Gestalts, such as cuboids, seem to need longer processing times to show ungrouping effects as observed in crowding. Strong parallels between masking and crowding suggest similar underlying mechanism; however, temporal factors in masking additionally modulate performance, acting as an additional grouping cue. © 2014 ARVO.
The subjective importance of noise spectral content
NASA Astrophysics Data System (ADS)
Baxter, Donald; Phillips, Jonathan; Denman, Hugh
2014-01-01
This paper presents secondary Standard Quality Scale (SQS2) rankings in overall quality JNDs for a subjective analysis of the 3 axes of noise, amplitude, spectral content, and noise type, based on the ISO 20462 softcopy ruler protocol. For the initial pilot study, a Python noise simulation model was created to generate the matrix of noise masks for the softcopy ruler base images with different levels of noise, different low pass filter noise bandwidths and different band pass filter center frequencies, and 3 different types of noise: luma only, chroma only, and luma and chroma combined. Based on the lessons learned, the full subjective experiment, involving 27 observers from Google, NVIDIA and STMicroelectronics was modified to incorporate a wider set of base image scenes, and the removal of band pass filtered noise masks to ease observer fatigue. Good correlation was observed with the Aptina subjective noise study. The absence of tone mapping in the noise simulation model visibly reduced the contrast at high levels of noise, due to the clipping of the high levels of noise near black and white. Under the 34-inch viewing distance, no significant difference was found between the luma only noise masks and the combined luma and chroma noise masks. This was not the intuitive expectation. Two of the base images with large uniform areas, `restaurant' and `no parking', were found to be consistently more sensitive to noise than the texture rich scenes. Two key conclusions are (1) there are fundamentally different sensitivities to noise on a flat patch versus noise in real images and (2) magnification of an image accentuates visual noise in a way that is non-representative of typical noise reduction algorithms generating the same output frequency. Analysis of our experimental noise masks applied to a synthetic Macbeth ColorChecker Chart confirmed the color-dependent nature of the visibility of luma and chroma noise.
Zovko, Monika; Kiefer, Markus
2013-02-01
According to classical theories, automatic processes operate independently of attention. Recent evidence, however, shows that masked visuomotor priming, an example of an automatic process, depends on attention to visual form versus semantics. In a continuation of this approach, we probed feature-specific attention within the perceptual domain and tested in two event-related potential (ERP) studies whether masked visuomotor priming in a shape decision task specifically depends on attentional sensitization of visual pathways for shape in contrast to color. Prior to the masked priming procedure, a shape or a color decision task served to induce corresponding task sets. ERP analyses revealed visuomotor priming effects over the occipitoparietal scalp only after the shape, but not after the color induction task. Thus, top-down control coordinates automatic processing streams in congruency with higher-level goals even at a fine-grained level. Copyright © 2012 Society for Psychophysiological Research.
Visual Masking in Schizophrenia: Overview and Theoretical Implications
Green, Michael F.; Lee, Junghee; Wynn, Jonathan K.; Mathis, Kristopher I.
2011-01-01
Visual masking provides several key advantages for exploring the earliest stages of visual processing in schizophrenia: it allows for control over timing at the millisecond level, there are several well-supported theories of the underlying neurobiology of visual masking, and it is amenable to examination by electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI). In this paper, we provide an overview of the visual masking impairment schizophrenia, including the relevant theoretical mechanisms for masking impairment. We will discuss its relationship to clinical symptoms, antipsychotic medications, diagnostic specificity, and presence in at-risk populations. As part of this overview, we will cover the neural correlates of visual masking based on recent findings from EEG and fMRI. Finally, we will suggest a possible mechanism that could explain the patterns of masking findings and other visual processing findings in schizophrenia. PMID:21606322
NASA Astrophysics Data System (ADS)
Lang, Jun; Zhang, Jing
2015-03-01
In our proposed optical image cryptosystem, two pairs of phase-amplitude masks are generated from the chaotic web map for image encryption in the 4f double random phase-amplitude encoding (DRPAE) system. Instead of transmitting the real keys and the enormous masks codes, only a few observed measurements intermittently chosen from the masks are delivered. Based on compressive sensing paradigm, we suitably refine the series expansions of web map equations to better reconstruct the underlying system. The parameters of the chaotic equations can be successfully calculated from observed measurements and then can be used to regenerate the correct random phase-amplitude masks for decrypting the encoded information. Numerical simulations have been performed to verify the proposed optical image cryptosystem. This cryptosystem can provide a new key management and distribution method. It has the advantages of sufficiently low occupation of the transmitted key codes and security improvement of information transmission without sending the real keys.
Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo; Kawai, Nobuyuki
2012-01-01
A Noh mask worn by expert actors when performing on a Japanese traditional Noh drama is suggested to convey countless different facial expressions according to different angles of head/body orientation. The present study addressed the question of how different facial parts of a Noh mask, including the eyebrows, the eyes, and the mouth, may contribute to different emotional expressions. Both experimental situations of active creation and passive recognition of emotional facial expressions were introduced. In Experiment 1, participants either created happy or sad facial expressions, or imitated a face that looked up or down, by actively changing each facial part of a Noh mask image presented on a computer screen. For an upward tilted mask, the eyebrows and the mouth shared common features with sad expressions, whereas the eyes with happy expressions. This contingency tended to be reversed for a downward tilted mask. Experiment 2 further examined which facial parts of a Noh mask are crucial in determining emotional expressions. Participants were exposed to the synthesized Noh mask images with different facial parts expressing different emotions. Results clearly revealed that participants primarily used the shape of the mouth in judging emotions. The facial images having the mouth of an upward/downward tilted Noh mask strongly tended to be evaluated as sad/happy, respectively. The results suggest that Noh masks express chimeric emotional patterns, with different facial parts conveying different emotions This appears consistent with the principles of Noh which highly appreciate subtle and composite emotional expressions, as well as with the mysterious facial expressions observed in Western art. It was further demonstrated that the mouth serves as a diagnostic feature in characterizing the emotional expressions. This indicates the superiority of biologically-driven factors over the traditionally formulated performing styles when evaluating the emotions of the Noh masks.
Miyata, Hiromitsu; Nishimura, Ritsuko; Okanoya, Kazuo; Kawai, Nobuyuki
2012-01-01
Background A Noh mask worn by expert actors when performing on a Japanese traditional Noh drama is suggested to convey countless different facial expressions according to different angles of head/body orientation. The present study addressed the question of how different facial parts of a Noh mask, including the eyebrows, the eyes, and the mouth, may contribute to different emotional expressions. Both experimental situations of active creation and passive recognition of emotional facial expressions were introduced. Methodology/Principal Findings In Experiment 1, participants either created happy or sad facial expressions, or imitated a face that looked up or down, by actively changing each facial part of a Noh mask image presented on a computer screen. For an upward tilted mask, the eyebrows and the mouth shared common features with sad expressions, whereas the eyes with happy expressions. This contingency tended to be reversed for a downward tilted mask. Experiment 2 further examined which facial parts of a Noh mask are crucial in determining emotional expressions. Participants were exposed to the synthesized Noh mask images with different facial parts expressing different emotions. Results clearly revealed that participants primarily used the shape of the mouth in judging emotions. The facial images having the mouth of an upward/downward tilted Noh mask strongly tended to be evaluated as sad/happy, respectively. Conclusions/Significance The results suggest that Noh masks express chimeric emotional patterns, with different facial parts conveying different emotions This appears consistent with the principles of Noh which highly appreciate subtle and composite emotional expressions, as well as with the mysterious facial expressions observed in Western art. It was further demonstrated that the mouth serves as a diagnostic feature in characterizing the emotional expressions. This indicates the superiority of biologically-driven factors over the traditionally formulated performing styles when evaluating the emotions of the Noh masks. PMID:23185595
NASA Astrophysics Data System (ADS)
Malloy, Matt; Litt, Lloyd C.
2012-11-01
A survey supported by SEMATECH and administered by David Powell Consulting was sent to semiconductor industry leaders to gather information about the mask industry as an objective assessment of its overall condition. The survey was designed with the input of semiconductor company mask technologists and merchant mask suppliers. 2012 marks the 11th consecutive year for the mask industry survey. This year's survey and reporting structure are similar to those of the previous years with minor modifications based on feedback from past years and the need to collect additional data on key topics. Categories include general mask information, mask processing, data and write time, yield and yield loss, delivery times, and maintenance and returns. Within each category are multiple questions that result in a detailed profile of both the business and technical status of the mask industry. Results, initial observations, and key comparisons between the 2011 and 2012 survey responses are shown here, including multiple indications of a shift towards the manufacturing of higher end photomasks.
Perea, Manuel; Marcet, Ana; Lozano, Mario; Gomez, Pablo
2018-05-29
One of the key assumptions of the masked priming lexical decision task (LDT) is that primes are processed without requiring attentional resources. Here, we tested this assumption by presenting a dual-task manipulation to increase memory load and measure the change in masked identity priming on the targets in the LDT. If masked priming does not require attentional resources, increased memory load should have no influence on the magnitude of the observed identity priming effects. We conducted two LDT experiments, using a within-subjects design, to investigate the effect of memory load (via a concurrent matching task Experiment 1 and a concurrent search task in Experiment 2) on masked identity priming. Results showed that the magnitude of masked identity priming on word targets was remarkably similar under high and low memory load. Thus, these experiments provide empirical evidence for the automaticity assumption of masked identity priming in the LDT.
Brand, Serge; Annen, Hubert; Holsboer-Trachsler, Edith; Blaser, Andreas
2011-10-01
Wearing a protective mask is compulsory for those in professions such as fire-fighters, rescue personnel and soldiers. The phobia to wear a protective mask is considered a specific claustrophobia and may become of major concern during military service. To date, no data are available with respect to the hypothalamus-pituitary-adrenocortical system activity (HPA SA) for both the so-called protective mask phobia (PMP) and its treatment. The aim of the present study was three-fold: 1) to assess HPA SA in soldiers suffering from PMP before and after intensive cognitive-behavioral treatment, 2) to compare these data with controls, and 3) to relate these data to subjective sleep. 46 Swiss Army recruits suffering from PMP were enrolled in a two-day intensive treatment course. During initial and final assessments, saliva was sampled to analyse HPA SA via salivary cortisol; saliva samples were also gathered in the morning. For comparison, saliva samples were gathered of 39 Emergency Rescue Service (ERS) recruits. All participants also completed a questionnaire related to sleep and to anxiety. Compared to controls from the ERS, among army recruits suffering from PMP, cortisol secretion was significantly higher during initial and final assessments, and in the morning. Cortisol secretion decreased from initial and final assessment. Subjectively assessed sleep was more impaired in recruits suffering from PMP compared to controls. After cognitive-behavioral treatment, all recruits suffering from PMP were able to wear the protective mask. Specific phobia about wearing a protective mask is treatable via a two-day intensive course. Treatment success is reflected in modified HPA SA. Methodology and results may be transferred to treat patients suffering from sleep apnea syndrome and presenting high anxiety about wearing continuous positive airway pressure devices. Copyright © 2011 Elsevier Ltd. All rights reserved.
Tinnitus retraining therapy: mixing point and total masking are equally effective.
Tyler, Richard S; Noble, William; Coelho, Claudia Barros; Ji, Haihong
2012-01-01
Habituation to tinnitus cannot occur with total masking, an argument made by proponents of "tinnitus retraining therapy." We also compared the effectiveness of retraining therapy with mixing-point masking, total masking, and with counseling alone. Forty-eight tinnitus patients were randomly assigned to one of three groups: counseling, counseling plus bilateral noise generators set to completely mask the tinnitus, or counseling plus bilateral noise generators with a focus on the mixing point (partial masking just below total masking). A picture-based counseling protocol was used to assist in providing similar counseling among all three groups. The Tinnitus Handicap Questionnaire was administered before and after about 12 months of treatment. After 12 months, in the counseling group, three of 18 patients benefited significantly, in the mixing-point group, six of 19 patients benefited, and in the total masking group, four of 11 patients benefited from the treatment. The average decrease in the questionnaire was 16.7% for the counseling group, 31.6% for the retraining group, and 36.4% for the total masking group. No significant average differences among groups were observed. One premise of retraining therapy is incorrect; a focus on mixing-point masking is not required for habituation.
Growth and certain chemical constituents of tobacco plants exposed to air ions
NASA Astrophysics Data System (ADS)
Barthakur, N. N.; Arnold, N. P.
1988-06-01
Controlled experiments were performed in Faraday cages on the effects of positive and negative air ions on flue-cured tobacco plants. Continuous exposures for 15 days to air ions showed no significant differences in any plant growth characteristic between the treated and control plants. Standard errors in the measurement of the growth parameters for ion exposed plants were, however, consistently higher than those of control plants. Spatial variation in concentration gradients of air ions produced by corona discharge might have contributed to masking of the relatively small effects of air ions on biological organisms observed in previous experiments in this laboratory. No significant difference was observed between the experimental and control plants in nicotine, total alkaloid, and reducing sugar contents. Total nitrogen content was slightly higher for treated than control plants.
Baldwin, Alex S; Baker, Daniel H; Hess, Robert F
2016-01-01
The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system's input has on its output one can estimate the variance of this internal noise. By applying this simple "linear amplifier" model to the human visual system, one can entirely explain an observer's detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system's internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity). Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF). We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies.
Propagation of resist heating mask error to wafer level
NASA Astrophysics Data System (ADS)
Babin, S. V.; Karklin, Linard
2006-10-01
As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the mask error budget - the resist heating CD error. In simulation of exposure using a stepper, variable MEEF was considered.
Automatic pattern localization across layout database and photolithography mask
NASA Astrophysics Data System (ADS)
Morey, Philippe; Brault, Frederic; Beisser, Eric; Ache, Oliver; Röth, Klaus-Dieter
2016-03-01
Advanced process photolithography masks require more and more controls for registration versus design and critical dimension uniformity (CDU). The distribution of the measurement points should be distributed all over the whole mask and may be denser in areas critical to wafer overlay requirements. This means that some, if not many, of theses controls should be made inside the customer die and may use non-dedicated patterns. It is then mandatory to access the original layout database to select patterns for the metrology process. Finding hundreds of relevant patterns in a database containing billions of polygons may be possible, but in addition, it is mandatory to create the complete metrology job fast and reliable. Combining, on one hand, a software expertise in mask databases processing and, on the other hand, advanced skills in control and registration equipment, we have developed a Mask Dataprep Station able to select an appropriate number of measurement targets and their positions in a huge database and automatically create measurement jobs on the corresponding area on the mask for the registration metrology system. In addition, the required design clips are generated from the database in order to perform the rendering procedure on the metrology system. This new methodology has been validated on real production line for the most advanced process. This paper presents the main challenges that we have faced, as well as some results on the global performances.
VizieR Online Data Catalog: Velocities in the A2345 cluster (Boschin+, 2010)
NASA Astrophysics Data System (ADS)
Boschin, W.; Barrena, R.; Girardi, M.
2011-08-01
Multi-object spectroscopic observations of A2345 were carried out at the TNG telescope in August 2008. We used DOLORES/MOS with the LR-B Grism 1, yielding a dispersion of 187Å/mm. We used the new E2V CCD, a matrix of 2048x2048 pixels with a pixel size of 13.5um. In total we observed four MOS masks for a total of 147 slits. Total exposure times were of 1h for three masks and 1.5h for the remaining mask. (1 data file).
Wutz, Andreas; Weisz, Nathan; Braun, Christoph; Melcher, David
2014-01-22
Dynamic vision requires both stability of the current perceptual representation and sensitivity to the accumulation of sensory evidence over time. Here we study the electrophysiological signatures of this intricate balance between temporal segregation and integration in vision. Within a forward masking paradigm with short and long stimulus onset asynchronies (SOA), we manipulated the temporal overlap of the visual persistence of two successive transients. Human observers enumerated the items presented in the second target display as a measure of the informational capacity read-out from this partly temporally integrated visual percept. We observed higher β-power immediately before mask display onset in incorrect trials, in which enumeration failed due to stronger integration of mask and target visual information. This effect was timescale specific, distinguishing between segregation and integration of visual transients that were distant in time (long SOA). Conversely, for short SOA trials, mask onset evoked a stronger visual response when mask and targets were correctly segregated in time. Examination of the target-related response profile revealed the importance of an evoked α-phase reset for the segregation of those rapid visual transients. Investigating this precise mapping of the temporal relationships of visual signals onto electrophysiological responses highlights how the stream of visual information is carved up into discrete temporal windows that mediate between segregated and integrated percepts. Fragmenting the stream of visual information provides a means to stabilize perceptual events within one instant in time.
Santos-Folgar, Myriam; Otero-Agra, Martín; Fernández-Méndez, Felipe; Hermo-Gonzalo, María Teresa; Barcala-Furelos, Roberto; Rodríguez-Núñez, Antonio
2018-02-08
It has been observed that health professionals have difficulty performing quality cardiopulmonary resuscitation (CPR). The aim of this study was to compare the quality of ventilations performed by Nursing students on an infant model using different methods (mouth-to-mouth-and-nose or bag-valve-mask). A quasi-experimental cross-sectional study was performed that included 46 second-year Nursing students. Two quantitative 4-minute tests of paediatric CPR were performed: a) mouth-to-mouth-and-nose ventilations, and b) ventilations with bag-valve-mask. A Resusci Baby QCPR Wireless SkillReporter® mannequin from Laerdal was used. The proportion of ventilations with adequate, excessive, and insufficient volume was recorded and analysed, as well as the overall quality of the CPR (ventilations and chest compressions). The students were able to give a higher number of ventilations with adequate volume using the mouth-to-mouth-and-nose method (55±22%) than with the bag-valve-mask (28±16%, P<.001). The overall quality of the CPR was also significantly higher when using the mouth-to-mouth-and-nose method (60±19 vs. 48±16%, P<.001). Mouth-to-mouth-and-nose ventilation method is more efficient than bag-valve-mask ventilations in CPR performed by nursing students with a simulated infant model. Copyright © 2018. Publicado por Elsevier España, S.L.U.
Lazarova, Valentina; Abed, Brahim; Markovska, Gabriela; Dezenclos, Thierry; Amara, Aït
2013-01-01
This paper presents and discusses the results of the project named 'Jasmin' implemented in Algiers to control the strong odours of the river named Oued El Harrach, one of the largest rivers in the centre of the city. Pending the achievement of curative solutions, a temporary option for mitigation of nuisance odour by masking agents was implemented in the vicinity of the main bridges. The efficiency of this technology has been followed by means of an odour panel with the participation of representatives of all stakeholders. A sociological study by means of 1,000 questionnaires and face-to-face interviews of the local population demonstrated the benefits and the positive outcomes of the attenuation of odour nuisance: 70% of the surveyed population is satisfied or very satisfied with the application of masking agents and 96% of respondents support the continuation of the project. In terms of size and public access, the project Jasmin is a world-first demonstration of odour control in urban areas in developing countries.
Masking of sounds by a background noise--cochlear mechanical correlates.
Recio-Spinoso, Alberto; Cooper, Nigel P
2013-05-15
In the search for cochlear correlates of auditory masking by noise stimuli, we recorded basilar membrane (BM) vibrations evoked by either tone or click signals in the presence of varying levels of background noise. The BM vibrations were recorded from basal regions in healthy cochleae of anaesthetized chinchilla and gerbil. Non-linear interactions that could underpin various aspects of psychophysical masking data, including both compression and suppression at the BM level, were observed. The suppression effects, whereby the amplitude of the responses to each stimulus component could be reduced, depended on the relative intensities of the noise and the tones or clicks. Only stimulus components whose frequencies fell inside the non-linear region of the recording site, i.e. around its characteristic frequency (CF), were affected by presentation of the 'suppressing' stimulus (which could be either the tone or the noise). Mutual suppression, the simultaneous reduction of the responses to both tones and noise components, was observed under some conditions, but overall reductions of BM vibration were rarely observed. Moderate- to high-intensity tones suppressed BM responses to low-intensity Gaussian stimuli, including both broadband and narrowband noise. Suppression effects were larger for spectral components of the noise response that were closer to the CF. In this regime, the tone and noise stimuli became the suppressor and probe signals, respectively. This study provides the first detailed observations of cochlear mechanical correlates of the masking effects of noise. Mechanical detection thresholds for tone signals, which were arbitrarily defined using three criteria, are shown to increase in almost direct proportion to the noise level for low and moderately high noise levels, in a manner that resembles the findings of numerous psychophysical observations.
Masking of sounds by a background noise – cochlear mechanical correlates
Recio-Spinoso, Alberto; Cooper, Nigel P
2013-01-01
In the search for cochlear correlates of auditory masking by noise stimuli, we recorded basilar membrane (BM) vibrations evoked by either tone or click signals in the presence of varying levels of background noise. The BM vibrations were recorded from basal regions in healthy cochleae of anaesthetized chinchilla and gerbil. Non-linear interactions that could underpin various aspects of psychophysical masking data, including both compression and suppression at the BM level, were observed. The suppression effects, whereby the amplitude of the responses to each stimulus component could be reduced, depended on the relative intensities of the noise and the tones or clicks. Only stimulus components whose frequencies fell inside the non-linear region of the recording site, i.e. around its characteristic frequency (CF), were affected by presentation of the ‘suppressing’ stimulus (which could be either the tone or the noise). Mutual suppression, the simultaneous reduction of the responses to both tones and noise components, was observed under some conditions, but overall reductions of BM vibration were rarely observed. Moderate- to high-intensity tones suppressed BM responses to low-intensity Gaussian stimuli, including both broadband and narrowband noise. Suppression effects were larger for spectral components of the noise response that were closer to the CF. In this regime, the tone and noise stimuli became the suppressor and probe signals, respectively. This study provides the first detailed observations of cochlear mechanical correlates of the masking effects of noise. Mechanical detection thresholds for tone signals, which were arbitrarily defined using three criteria, are shown to increase in almost direct proportion to the noise level for low and moderately high noise levels, in a manner that resembles the findings of numerous psychophysical observations. PMID:23478137
Kitagawa, Kory H; Nakamura, Nina M; Yamamoto, Loren
2006-03-01
To measure the ventilation efficacy with three single-sized mask types on infant and child manikin models. Medical students were recruited as study subjects inasmuch as they are inexperienced resuscitators. They were taught proper bag-mask ventilation (BMV) according to the American Heart Association guidelines on an infant and a child manikin. Subjects completed a BMV attempt successfully using the adult standard mask (to simulate the uncertainty of mask selection), pocket mask, and blob mask. Each attempt consisted of 5 ventilations assessed by chest rise of the manikin. Study subjects were asked which mask was easiest to use. Four to six weeks later, subjects repeated the procedure with no instructions (to simulate an emergency BMV encounter without immediate pre-encounter teaching). Forty-six volunteer subjects were studied. During the first attempt, subjects preferred the standard and blob masks over the pocket mask. For the second attempt, the blob mask was preferred over the standard mask, and few liked the pocket mask. Using the standard, blob, and pocket masks on the child manikin, 39, 42, and 20 subjects, respectively, were able to achieve adequate ventilation. Using the standard, blob, and pocket masks on the infant manikin, 45, 45, and 11 subjects, respectively, were able to achieve adequate ventilation. Both the standard and blob masks are more effective than the pocket mask at achieving adequate ventilation on infant and child manikins in this group of inexperienced medical student resuscitators, who most often preferred the blob mask.
NASA Astrophysics Data System (ADS)
Xu, Zhe; Peng, M. G.; Tu, Lin Hsin; Lee, Cedric; Lin, J. K.; Jan, Jian Feng; Yin, Alb; Wang, Pei
2006-10-01
Nowadays, most foundries have paid more and more attention in order to reduce the CD width. Although the lithography technologies have developed drastically, mask data accuracy is still a big challenge than before. Besides, mask (reticle) price also goes up drastically such that data accuracy needs more special treatments.We've developed a system called eFDMS to guarantee the mask data accuracy. EFDMS is developed to do the automatic back-check of mask tooling database and the data transmission of mask tooling. We integrate our own EFDMS systems to engage with the standard mask tooling system K2 so that the upriver and the downriver processes of the mask tooling main body K2 can perform smoothly and correctly with anticipation. The competition in IC marketplace is changing from high-tech process to lower-price gradually. How to control the reduction of the products' cost more plays a significant role in foundries. Before the violent competition's drawing nearer, we should prepare the cost task ahead of time.
Peters, Megan A K; Lau, Hakwan
2015-01-01
Many believe that humans can ‘perceive unconsciously’ – that for weak stimuli, briefly presented and masked, above-chance discrimination is possible without awareness. Interestingly, an online survey reveals that most experts in the field recognize the lack of convincing evidence for this phenomenon, and yet they persist in this belief. Using a recently developed bias-free experimental procedure for measuring subjective introspection (confidence), we found no evidence for unconscious perception; participants’ behavior matched that of a Bayesian ideal observer, even though the stimuli were visually masked. This surprising finding suggests that the thresholds for subjective awareness and objective discrimination are effectively the same: if objective task performance is above chance, there is likely conscious experience. These findings shed new light on decades-old methodological issues regarding what it takes to consider a neurobiological or behavioral effect to be 'unconscious,' and provide a platform for rigorously investigating unconscious perception in future studies. DOI: http://dx.doi.org/10.7554/eLife.09651.001 PMID:26433023
Factors responsible for remote-frequency masking in children and adultsa)
Leibold, Lori J.; Buss, Emily
2016-01-01
Susceptibility to remote-frequency masking in children and adults was evaluated with respect to three stimulus features: (1) masker bandwidth, (2) spectral separation of the signal and masker, and (3) gated versus continuous masker presentation. Listeners were 4- to 6-year-olds, 7- to 10-year-olds, and adults. Detection thresholds for a 500-ms, 2000-Hz signal were estimated in quiet or presented with a band of noise in one of four frequency regions: 425–500 Hz, 4000–4075 Hz, 8000–8075 Hz, or 4000–10 000 Hz. In experiment 1, maskers were gated on in each 500-ms interval of a three-interval, forced-choice adaptive procedure. Masking was observed for all ages in all maskers, but the greatest masking was observed for the 4000–4075 Hz masker. These findings suggest that signal/masker spectral proximity plays an important role in remote-frequency masking, even when peripheral excitation associated with the signal and masker does not overlap. Younger children tended to have more masking than older children or adults, consistent with a reduced ability to segregate simultaneous sounds and/or listen in a frequency-selective manner. In experiment 2, detection thresholds were estimated in the same noises, but maskers were presented continuously. Masking was reduced for all ages relative to gated conditions, suggesting improved segregation and/or frequency-selective listening. PMID:28040030
Masks for prevention of respiratory viruses on the BMT unit: results of a quality initiative.
Sokol, Kelsey A; De la Vega-Diaz, Imelda; Edmondson-Martin, Kathleen; Kim, Sara; Tindle, Sharon; Wallach, Fran; Steinberg, Amir
2016-12-01
Respiratory viral infections (RVI) cause significant morbidity and mortality in hospitalized oncology patients. These viruses are easily spread from asymptomatic and/or symptomatic healthcare workers and visitors to immunocompromised patients, and literature review of facemasks for prevention of infection revealed mixed results. The Bone Marrow Transplant (BMT) Quality Assurance (QA) Committee at Mount Sinai began a surgical mask initiative on the BMT unit. The purpose of our initiative was to assess the impact of surgical mask implementation for healthcare workers and visitors on nosocomial RVI in all patients hospitalized on the BMT unit. We hypothesized that implementing surgical masks would reduce the number of hospital-acquired RVI. We performed a retrospective study involving all patients with malignancy hospitalized on the BMT unit for 4 years. During the latter 2 years, all healthcare workers and visitors were required to wear a surgical mask in every patient room on the BMT unit. Primary endpoint was incidence of RVI after implementation of surgical masks. The 2-year incidence of RVI in the pre-mask period was 14 out of a total of 15 001 patient days on the unit vs 2 out of 15 608 patient days after mask implementation. The difference in incidence of RVI within the two time intervals was noted to be statistically significant (P<.05, 2-proportion z-test). Our quality initiative demonstrated that surgical masks are an infection control modality that may provide benefit to oncology/BMT units by decreasing the risk for hospital-acquired RVI. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Prevention of influenza at Hajj: applications for mass gatherings.
Haworth, Elizabeth; Barasheed, Osamah; Memish, Ziad A; Rashid, Harunor; Booy, Robert
2013-06-01
Outbreaks of infectious diseases that spread via respiratory route, e.g. influenza, are common amongst Hajj congregation in Mecca, Saudi Arabia. The Saudi Arabian authority successfully organized the Hajj 2009 amidst fear of pandemic influenza. While severe influenza A(H1N1)pdm09 was rare, the true burden of pandemic influenza at Hajj that year remains speculative. In this article we review the latest evidence on influenza control and discuss our experience of influenza and its prevention at Hajj and possible application to other mass gatherings. Depending on study design the attack rate of seasonal influenza at Hajj has ranged from 6% in polymerase chain reaction or culture confirmed studies to 38% in serological surveillance. No significant effect of influenza vaccine or the use of personal protective measures against influenza has been established from observational studies, although the uptake of the vaccine and adherence to face masks and hand hygiene has been low. In all, there is a relatively poor evidence base for control of influenza. Until better evidence is obtained, vaccination coupled with rapid antiviral treatment of symptomatic individuals remains the mainstay of prevention at Hajj and other mass gatherings. Hajj pilgrimage provides a unique opportunity to test the effectiveness of various preventive measures that require a large sample size, such as testing the efficacy of plain surgical masks against laboratory-confirmed influenza. After successful completion of a pilot trial conducted among Australian pilgrims at the 2011 Hajj, a large multinational cluster randomized controlled trial is being planned. This will require effective international collaboration.
Structural colour printing from a reusable generic nanosubstrate masked for the target image
NASA Astrophysics Data System (ADS)
Rezaei, M.; Jiang, H.; Kaminska, B.
2016-02-01
Structural colour printing has advantages over traditional pigment-based colour printing. However, the high fabrication cost has hindered its applications in printing large-area images because each image requires patterning structural pixels in nanoscale resolution. In this work, we present a novel strategy to print structural colour images from a pixelated substrate which is called a nanosubstrate. The nanosubstrate is fabricated only once using nanofabrication tools and can be reused for printing a large quantity of structural colour images. It contains closely packed arrays of nanostructures from which red, green, blue and infrared structural pixels can be imprinted. To print a target colour image, the nanosubstrate is first covered with a mask layer to block all the structural pixels. The mask layer is subsequently patterned according to the target colour image to make apertures of controllable sizes on top of the wanted primary colour pixels. The masked nanosubstrate is then used as a stamp to imprint the colour image onto a separate substrate surface using nanoimprint lithography. Different visual colours are achieved by properly mixing the red, green and blue primary colours into appropriate ratios controlled by the aperture sizes on the patterned mask layer. Such a strategy significantly reduces the cost and complexity of printing a structural colour image from lengthy nanoscale patterning into high throughput micro-patterning and makes it possible to apply structural colour printing in personalized security features and data storage. In this paper, nanocone array grating pixels were used as the structural pixels and the nanosubstrate contains structures to imprint the nanocone arrays. Laser lithography was implemented to pattern the mask layer with submicron resolution. The optical properties of the nanocone array gratings are studied in detail. Multiple printed structural colour images with embedded covert information are demonstrated.
NASA Astrophysics Data System (ADS)
Kim, H. W.; Yeom, J. M.; Woo, S. H.
2017-12-01
Over the thin cloud region, satellite can simultaneously detect the reflectance from thin clouds and land surface. Since the mixed reflectance is not the exact cloud information, the background surface reflectance should be eliminated to accurately distinguish thin cloud such as cirrus. In the previous research, Kim et al (2017) was developed the cloud masking algorithm using the Geostationary Ocean Color Imager (GOCI), which is one of significant instruments for Communication, Ocean, and Meteorology Satellite (COMS). Although GOCI has 8 spectral channels including visible and near infra-red spectral ranges, the cloud masking has quantitatively reasonable result when comparing with MODIS cloud mask (Collection 6 MYD35). Especially, we noticed that this cloud masking algorithm is more specialized in thin cloud detections through the validation with Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) data. Because this cloud masking method was concentrated on eliminating background surface effects from the top-of-atmosphere (TOA) reflectance. Applying the difference between TOA reflectance and the bi-directional reflectance distribution function (BRDF) model-based background surface reflectance, cloud areas both thick cloud and thin cloud can be discriminated without infra-red channels which were mostly used for detecting clouds. Moreover, when the cloud mask result was utilized as the input data when simulating BRDF model and the optimized BRDF model-based surface reflectance was used for the optimized cloud masking, the probability of detection (POD) has higher value than POD of the original cloud mask. In this study, we examine the correlation between cloud optical depth (COD) and its cloud mask result. Cloud optical depths mostly depend on the cloud thickness, the characteristic of contents, and the size of cloud contents. COD ranges from less than 0.1 for thin clouds to over 1000 for the huge cumulus due to scattering by droplets. With the cloud optical depth of CALIPSO, the cloud masking result can be more improved since we can figure out how deep cloud is. To validate the cloud mask and the correlation result, the atmospheric retrieval will be computed to compare the difference between TOA reflectance and the simulated surface reflectance.
Koelkebeck, Katja; Kohl, Waldemar; Luettgenau, Julia; Triantafillou, Susanna; Ohrmann, Patricia; Satoh, Shinji; Minoshita, Seiko
2015-07-30
A novel emotion recognition task that employs photos of a Japanese mask representing a highly ambiguous stimulus was evaluated. As non-Asians perceive and/or label emotions differently from Asians, we aimed to identify patterns of task-performance in non-Asian healthy volunteers with a view to future patient studies. The Noh mask test was presented to 42 adult German participants. Reaction times and emotion attribution patterns were recorded. To control for emotion identification abilities, a standard emotion recognition task was used among others. Questionnaires assessed personality traits. Finally, results were compared to age- and gender-matched Japanese volunteers. Compared to other tasks, German participants displayed slowest reaction times on the Noh mask test, indicating higher demands of ambiguous emotion recognition. They assigned more positive emotions to the mask than Japanese volunteers, demonstrating culture-dependent emotion identification patterns. As alexithymic and anxious traits were associated with slower reaction times, personality dimensions impacted on performance, as well. We showed an advantage of ambiguous over conventional emotion recognition tasks. Moreover, we determined emotion identification patterns in Western individuals impacted by personality dimensions, suggesting performance differences in clinical samples. Due to its properties, the Noh mask test represents a promising tool in the differential diagnosis of psychiatric disorders, e.g. schizophrenia. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Surgical Mask to Prevent Influenza Transmission in Households: A Cluster Randomized Trial
Canini, Laetitia; Andréoletti, Laurent; Ferrari, Pascal; D'Angelo, Romina; Blanchon, Thierry; Lemaitre, Magali; Filleul, Laurent; Ferry, Jean-Pierre; Desmaizieres, Michel; Smadja, Serge; Valleron, Alain-Jacques; Carrat, Fabrice
2010-01-01
Background Facemasks and respirators have been stockpiled during pandemic preparedness. However, data on their effectiveness for limiting transmission are scarce. We evaluated the effectiveness of facemask use by index cases for limiting influenza transmission by large droplets produced during coughing in households. Methodology and Principal Findings A cluster randomized intervention trial was conducted in France during the 2008–2009 influenza season. Households were recruited during a medical visit of a household member with a positive rapid influenza A test and symptoms lasting less than 48 hours. Households were randomized either to the mask or control group for 7 days. In the intervention arm, the index case had to wear a surgical mask from the medical visit and for a period of 5 days. The trial was initially intended to include 372 households but was prematurely interrupted after the inclusion of 105 households (306 contacts) following the advice of an independent steering committee. We used generalized estimating equations to test the association between the intervention and the proportion of household contacts who developed an influenza-like illness during the 7 days following the inclusion. Influenza-like illness was reported in 24/148 (16.2%) of the contacts in the intervention arm and in 25/158 (15.8%) of the contacts in the control arm and the difference between arms was 0.40% (95%CI: −10% to 11%, P = 1.00). We observed a good adherence to the intervention. In various sensitivity analyses, we did not identify any trend in the results suggesting effectiveness of facemasks. Conclusion This study should be interpreted with caution since the lack of statistical power prevents us to draw formal conclusion regarding effectiveness of facemasks in the context of a seasonal epidemic. Trial Registration clinicaltrials.gov NCT00774774 PMID:21103330
Maignen, Francois; Hauben, Manfred; Hung, Eric; Van Holle, Lionel; Dogne, Jean-Michel
2014-02-01
Masking is a statistical issue by which signals are hidden by the presence of other medicines in the database. In the absence algorithm, the impact of the masking effect has not been fully investigated. Our study is aimed at assessing the extent and the impact of the masking effect on two large spontaneous reporting databases. Cross sectional study using a set of terms of importance for public health in two spontaneous reporting databases. The analyses were performed on EudraVigilance (EV) and the Pfizer spontaneous reporting database (PfDB). Using the masking ratio, we have identified and removed the products inducing the highest masking effect. Studying a total of almost 50 000 drug-event combinations masking had an impact on approximately 60% of drug-event combinations were masked by another product with a masking ratio >1 in EV and 84% in PfDB. The prevalence of important masking was quite rare (0.003% of the DECs) and mainly affected events rarely reported in EV. The products involved in the highest masking effects are products known to induce the reaction. The removal of the masking effect of the highest masking product has revealed 974 signals of disproportionate reporting in EV including true signals. The study shows that the original ranking provided by the quantitative methods included in our study is marginally affected by the removal of the masking product. Our study suggests that significant masking is rare in large spontaneous databases and mostly affects events rarely reported in EV. Copyright © 2013 John Wiley & Sons, Ltd.
Li, Juanhua; Wu, Chao; Zheng, Yingjun; Li, Ruikeng; Li, Xuanzi; She, Shenglin; Wu, Haibo; Peng, Hongjun; Ning, Yuping; Li, Liang
2017-09-17
The superior temporal gyrus (STG) is involved in speech recognition against informational masking under cocktail-party-listening conditions. Compared to healthy listeners, people with schizophrenia perform worse in speech recognition under informational speech-on-speech masking conditions. It is not clear whether the schizophrenia-related vulnerability to informational masking is associated with certain changes in FC of the STG with some critical brain regions. Using sparse-sampling fMRI design, this study investigated the differences between people with schizophrenia and healthy controls in FC of the STG for target-speech listening against informational speech-on-speech masking, when a listening condition with either perceived spatial separation (PSS, with a spatial release of informational masking) or perceived spatial co-location (PSC, without the spatial release) between target speech and masking speech was introduced. The results showed that in healthy participants, but not participants with schizophrenia, the contrast of either the PSS or PSC condition against the masker-only condition induced an enhancement of functional connectivity (FC) of the STG with the left superior parietal lobule and the right precuneus. Compared to healthy participants, participants with schizophrenia showed declined FC of the STG with the bilateral precuneus, right SPL, and right supplementary motor area. Thus, FC of the STG with the parietal areas is normally involved in speech listening against informational masking under either the PSS or PSC conditions, and declined FC of the STG in people with schizophrenia with the parietal areas may be associated with the increased vulnerability to informational masking. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.
Kim, Nam-Gyoon
2015-01-01
The present study explored whether the optic flow deficit in Alzheimer's disease (AD) reported in the literature transfers to different types of optic flow, in particular, one that specifies collision impacts with upcoming surfaces, with a special focus on the effect of retinal eccentricity. Displays simulated observer movement over a ground plane toward obstacles lying in the observer's path. Optical expansion was modulated by varying [Formula: see text]. The visual field was masked either centrally (peripheral vision) or peripherally (central vision) using masks ranging from 10° to 30° in diameter in steps of 10°. Participants were asked to indicate whether their approach would result in "collision" or "no collision" with the obstacles. Results showed that AD patients' sensitivity to [Formula: see text] was severely compromised, not only for central vision but also for peripheral vision, compared to age- and education-matched elderly controls. The results demonstrated that AD patients' optic flow deficit is not limited to radial optic flow but includes also the optical pattern engendered by [Formula: see text]. Further deterioration in the capacity to extract [Formula: see text] to determine potential collisions in conjunction with the inability to extract heading information from radial optic flow would exacerbate AD patients' difficulties in navigation and visuospatial orientation.
NASA Astrophysics Data System (ADS)
Choi, Jaehyuck; Kim, Jinsu; Lowe, Jeff; Dattilo, Davide; Koh, Soowan; Choi, Jun Yeol; Dietze, Uwe; Shoki, Tsutomu; Kim, Byung Gook; Jeon, Chan-Uk
2015-10-01
EUV masks include many different layers of various materials rarely used in optical masks, and each layer of material has a particular role in enhancing the performance of EUV lithography. Therefore, it is crucial to understand how the mask quality and patterning performance can change during mask fabrication, EUV exposure, maintenance cleaning, shipping, or storage. SPM (Sulfuric acid peroxide mixture) which has been extensively used for acid cleaning of photomask and wafer has serious drawback for EUV mask cleaning. It shows severe film loss of tantalum-based absorber layers and limited removal efficiency of EUV-generated carbon contaminants on EUV mask surface. Here, we introduce such novel cleaning chemicals developed for EUV mask as almost film loss free for various layers of the mask and superior carbon removal performance. Combinatorial chemical screening methods allowed us to screen several hundred combinations of various chemistries and additives under several different process conditions of temperature and time, eventually leading to development of the best chemistry selections for EUV mask cleaning. Recently, there have been many activities for the development of EUV pellicle, driven by ASML and core EUV scanner customer companies. It is still important to obtain film-loss free cleaning chemicals because cleaning cycle of EUV mask should be much faster than that of optic mask mainly due to EUV pellicle lifetime. More frequent cleaning, combined with the adoption of new materials for EUV masks, necessitates that mask manufacturers closely examine the performance change of EUV masks during cleaning process. We have investigated EUV mask quality changes and film losses during 50 cleaning cycles using new chemicals as well as particle and carbon contaminant removal characteristics. We have observed that the performance of new chemicals developed is superior to current SPM or relevant cleaning chemicals for EUV mask cleaning and EUV mask lifetime elongation.
An experimental investigation of masking in the US FDA adverse event reporting system database.
Wang, Hsin-wei; Hochberg, Alan M; Pearson, Ronald K; Hauben, Manfred
2010-12-01
A phenomenon of 'masking' or 'cloaking' in pharmacovigilance data mining has been described, which can potentially cause signals of disproportionate reporting (SDRs) to be missed, particularly in pharmaceutical company databases. Masking has been predicted theoretically, observed anecdotally or studied to a limited extent in both pharmaceutical company and health authority databases, but no previous publication systematically assesses its occurrence in a large health authority database. To explore the nature, extent and possible consequences of masking in the US FDA Adverse Event Reporting System (AERS) database by applying various experimental unmasking protocols to a set of drugs and events representing realistic pharmacovigilance analysis conditions. This study employed AERS data from 2001 through 2005. For a set of 63 Medical Dictionary for Regulatory Activities (MedDRA®) Preferred Terms (PTs), disproportionality analysis was carried out with respect to all drugs included in the AERS database, using a previously described urn-model-based algorithm. We specifically sought masking in which drug removal induced an increase in the statistical representation of a drug-event combination (DEC) that resulted in the emergence of a new SDR. We performed a series of unmasking experiments selecting drugs for removal using rational statistical decision rules based on the requirement of a reporting ratio (RR) >1, top-ranked statistical unexpectedness (SU) and relatedness as reflected in the WHO Anatomical Therapeutic Chemical level 4 (ATC4) grouping. In order to assess the possible extent of residual masking we performed two supplemental purely empirical analyses on a limited subset of data. This entailed testing every drug and drug group to determine which was most influential in uncovering masked SDRs. We assessed the strength of external evidence for a causal association for a small number of masked SDRs involving a subset of 29 drugs for which level of evidence adjudication was available from a previous study. The original disproportionality analysis identified 8719 SDRs for the 63 PTs. The SU-based unmasking protocols generated variable numbers of masked SDRs ranging from 38 to 156, representing a 0.43-1.8% increase over the number of baseline SDRs. A significant number of baseline SDRs were also lost in the course of our experiments. The trend in the number of gained SDRs per report removed was inversely related to the number of lost SDRs per protocol. Both the number and nature of the reports removed influenced the number of gained SDRs observed. The purely empirical protocols unmasked up to ten times as many SDRs. None of the masked SDRs had strong external evidence supporting a causal association. Most involved associations for which there was no external supporting evidence or were in the original product label. For two masked SDRs, there was external evidence of a possible causal association. We documented masking in the FDA AERS database. Attempts at unmasking SDRs using practically implementable protocols produced only small changes in the output of SDRs in our analysis. This is undoubtedly related to the large size and diversity of the database, but the complex interdependencies between drugs and events in authentic spontaneous reporting system (SRS) databases, and the impact of measures of statistical variability that are typically used in real-world disproportionality analysis, may be additional factors that constrain the discovery of masked SDRs and which may also operate in pharmaceutical company databases. Empirical determination of the most influential drugs may uncover significantly more SDRs than protocols based on predetermined statistical selection rules but are impractical except possibly for evaluating specific events. Routine global exercises to elicit masking, especially in large health authority databases are not justified based on results available to date. Exercises to elicit unmasking should be driven by prior knowledge or obvious data imbalances.
Masking ability of a zirconia ceramic on composite resin substrate shades.
Tabatabaian, Farhad; Shabani, Sima; Namdari, Mahshid; Sadeghpour, Koroush
2017-01-01
Masking ability of a restorative material plays an important role to cover discolored tooth structure; however, this ability has not yet been well understood in zirconia-based restorations. This study assessed the masking ability of a zirconia ceramic on composite resin substrates with different shades. Ten zirconia disc specimens, with 0.5 mm thickness and 10 mm diameter, were fabricated by a computer-aided design/computer-aided manufacturing system. A white substrate (control) and six composite resin substrates with different shades including A1, A2, A3, B2, C2, and D3 were prepared. The substrates had a cylindrical shape with 10 mm diameter and height. The specimens were placed onto the substrates for spectrophotometric evaluation. A spectrophotometer measured the L*, a*, and b* values for the specimens. ΔE values were calculated to determine the color differences between the groups and the control and then were compared with a perceptional threshold (ΔE = 2.6). Repeated measures ANOVA and Bonferroni tests were used for data analysis ( P < 0.05). The mean and standard deviation of ΔE values for A1, A2, A3, B2, C2, and D3 groups were 6.78 ± 1.59, 8.13 ± 1.66, 9.81 ± 2.64, 9.61 ± 1.38, 9.59 ± 2.63, and 8.13 ± 1.89, respectively. A significant difference was found among the groups in the ΔE values ( P = 0.006). The ΔE values were more than the perceptional threshold in all the groups ( P < 0.0001). Within the limitations of this study, it can be concluded that the tested zirconia ceramic could not thoroughly mask different shades of the composite resin substrates. Moreover, color masking of zirconia depends on the shade of substrate.
Riquelme M, Hugo; Wood V, David; Martínez F, Santiago; Carmona M, Fernando; Peña V, Axel; Wegner A, Adriana
2017-06-01
Noninvasive ventilation (NIV) frequently involves the development of facial pressure ulcers (FPU). Its prevention considers the empirical use of protective patches between skin and mask, in order to reduce the pressure exerted by it. To evaluate the effect of protective patches on the pressure exerted by the facial mask, and its impact on the programmed ventilatory parameters. Bilevel NIV simulated model using full face mask in phantom with a physiological airway (ALS PRO +) in supine position. Forehead, chin and cheekbones pressure were measured using 3 types of standard protective patches versus a control group using pressure sensors (Interlinks Electronics®). The values obtained with the protective patches-mask model were evaluated in the programmed variables maximum inspiratory flow (MIF)), expired tidal volume (Vte) and positive inspiratory pressure (IPAP), with Trilogy 100 ventilator, Respironics®. The programming and recording of the variables was carried out in 8 opportunities in each group by independent operators. There was no decrease in facial pressure with any of the protective patches compared to the control group. Moltopren increased facial pressure at all support points (p < 0.001), increased leakage, it decreased MIF, Vte and IPAP (p < 0.001). Hydrocolloid patches increased facial pressure only in the left cheekbone, increased leakage and decreased MIF. Polyurethane patches did not produce changes in facial pressure or ventilatory variables. The use of protective patches of moltopren, hydrocolloid and polyurethane transparent did not contribute to the decrease of the facial pressure. A deleterious effect of the moltopren and hydrocolloid patches was observed on the administration of ventilatory variables, concluding that the non-use of the protective patches allowed a better administration of the programmed parameters.
Prospects of DUV OoB suppression techniques in EUV lithography
NASA Astrophysics Data System (ADS)
Park, Chang-Min; Kim, Insung; Kim, Sang-Hyun; Kim, Dong-Wan; Hwang, Myung-Soo; Kang, Soon-Nam; Park, Cheolhong; Kim, Hyun-Woo; Yeo, Jeong-Ho; Kim, Seong-Sue
2014-04-01
Though scaling of source power is still the biggest challenge in EUV lithography (EUVL) technology era, CD and overlay controls for transistor's requirement are also precondition of adopting EUVL in mass production. Two kinds of contributors are identified as risks for CDU and Overlay: Infrared (IR) and deep ultraviolet (DUV) out of band (OOB) radiations from laser produced plasma (LPP) EUV source. IR from plasma generating CO2 laser that causes optics heating and wafer overlay error is well suppressed by introducing grating on collector to diffract IR off the optical axis and is the effect has been confirmed by operation of pre-production tool (NXE3100). EUV and DUV OOB which are reflected from mask black boarder (BB) are root causes of EUV-specific CD error at the boundaries of exposed shots which would result in the problem of CDU out of spec unless sufficiently suppressed. Therefore, control of DUV OOB reflection from the mask BB is one of the key technologies that must be developed prior to EUV mass production. In this paper, quantitative assessment on the advantage and the disadvantage of potential OOB solutions will be discussed. EUV and DUV OOB impacts on wafer CDs are measured from NXE3100 & NXE3300 experiments. Significant increase of DUV OOB impact on CD from NXE3300 compared with NXE3100 is observed. There are three ways of technology being developed to suppress DUV OOB: spectral purity filter (SPF) as a scanner solution, multi-layer etching as a solution on mask, and resist top-coating as a process solution. PROs and CONs of on-scanner, on-mask, and on-resist solution for the mass production of EUV lithography will be discussed.
Integration of mask and silicon metrology in DFM
NASA Astrophysics Data System (ADS)
Matsuoka, Ryoichi; Mito, Hiroaki; Sugiyama, Akiyuki; Toyoda, Yasutaka
2009-03-01
We have developed a highly integrated method of mask and silicon metrology. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. We have inspected the high accuracy, stability and reproducibility in the experiments of integration. The accuracy is comparable with that of the mask and silicon CD-SEM metrology. In this report, we introduce the experimental results and the application. As shrinkage of design rule for semiconductor device advances, OPC (Optical Proximity Correction) goes aggressively dense in RET (Resolution Enhancement Technology). However, from the view point of DFM (Design for Manufacturability), the cost of data process for advanced MDP (Mask Data Preparation) and mask producing is a problem. Such trade-off between RET and mask producing is a big issue in semiconductor market especially in mask business. Seeing silicon device production process, information sharing is not completely organized between design section and production section. Design data created with OPC and MDP should be linked to process control on production. But design data and process control data are optimized independently. Thus, we provided a solution of DFM: advanced integration of mask metrology and silicon metrology. The system we propose here is composed of followings. 1) Design based recipe creation: Specify patterns on the design data for metrology. This step is fully automated since they are interfaced with hot spot coordinate information detected by various verification methods. 2) Design based image acquisition: Acquire the images of mask and silicon automatically by a recipe based on the pattern design of CD-SEM.It is a robust automated step because a wide range of design data is used for the image acquisition. 3) Contour profiling and GDS data generation: An image profiling process is applied to the acquired image based on the profiling method of the field proven CD metrology algorithm. The detected edges are then converted to GDSII format, which is a standard format for a design data, and utilized for various DFM systems such as simulation. Namely, by integrating pattern shapes of mask and silicon formed during a manufacturing process into GDSII format, it makes it possible to bridge highly accurate pattern profile information over to the design field of various EDA systems. These are fully integrated into design data and automated. Bi-directional cross probing between mask data and process control data is allowed by linking them. This method is a solution for total optimization that covers Design, MDP, mask production and silicon device producing. This method therefore is regarded as a strategic DFM approach in the semiconductor metrology.
Photomask etch system and process for 10nm technology node and beyond
NASA Astrophysics Data System (ADS)
Chandrachood, Madhavi; Grimbergen, Michael; Yu, Keven; Leung, Toi; Tran, Jeffrey; Chen, Jeff; Bivens, Darin; Yalamanchili, Rao; Wistrom, Richard; Faure, Tom; Bartlau, Peter; Crawford, Shaun; Sakamoto, Yoshifumi
2015-10-01
While the industry is making progress to offer EUV lithography schemes to attain ultimate critical dimensions down to 20 nm half pitch, an interim optical lithography solution to address an immediate need for resolution is offered by various integration schemes using advanced PSM (Phase Shift Mask) materials including thin e-beam resist and hard mask. Using the 193nm wavelength to produce 10nm or 7nm patterns requires a range of optimization techniques, including immersion and multiple patterning, which place a heavy demand on photomask technologies. Mask schemes with hard mask certainly help attain better selectivity and hence better resolution but pose integration challenges and defectivity issues. This paper presents a new photomask etch solution for attenuated phase shift masks that offers high selectivity (Cr:Resist > 1.5:1), tighter control on the CD uniformity with a 3sigma value approaching 1 nm and controllable CD bias (5-20 nm) with excellent CD linearity performance (<5 nm) down to the finer resolution. The new system has successfully demonstrated capability to meet the 10 nm node photomask CD requirements without the use of more complicated hard mask phase shift blanks. Significant improvement in post wet clean recovery performance was demonstrated by the use of advanced chamber materials. Examples of CD uniformity, linearity, and minimum feature size, and etch bias performance on 10 nm test site and production mask designs will be shown.
Masdeu, Maria J.; Patel, Amit V.; Seelall, Vijay; Rapoport, David M.; Ayappa, Indu
2012-01-01
Study Objectives: Patients with obstructive sleep apnea may have difficulty exhaling against positive pressure, hence limiting their acceptance of continuous positive airway pressure (CPAP). C-Flex is designed to improve comfort by reducing pressure in the mask during expiration proportionally to expiratory airflow (3 settings correspond to increasing pressure changes). When patients use CPAP, nasal resistance determines how much higher supraglottic pressure is than mask pressure. We hypothesized that increased nasal resistance results in increased expiratory supraglottic pressure swings that could be mitigated by the effects of C-Flex on mask pressure. Design: Cohort study. Setting: Sleep center. Participants: Seventeen patients with obstructive sleep apnea/hypopnea syndrome and a mechanical model of the upper airway. Interventions: In patients on fixed CPAP, CPAP with different C-Flex levels was applied multiple times during the night. In the model, 2 different respiratory patterns and resistances were tested. Measurements and Results: Airflow, expiratory mask, and supraglottic pressures were measured on CPAP and on C-Flex. Swings in pressure during expiration were determined. On CPAP, higher nasal resistance produced greater expiratory pressure swings in the supraglottis in the patients and in the model, as expected. C-Flex 3 produced expiratory drops in mask pressure (range −0.03 to −2.49 cm H2O) but mitigated the expira-tory pressure rise in the supraglottis only during a sinusoidal respiratory pattern in the model. Conclusions: Expiratory changes in mask pressure induced by C-Flex did not uniformly transmit to the supraglottis in either patients with obstructive sleep apnea on CPAP or in a mechanical model of the upper airway with fixed resistance. Data suggest that the observed lack of expiratory drop in supraglottic pressure swings is related to dynamics of the C-Flex algorithm. Citation: Masdeu MJ; Patel AV; Seelall V; Rapoport DM; Ayappa I. The supraglottic effect of a reduction in expiratory mask pressure during continuous positive airway pressure. SLEEP 2012;35(2):263-272. PMID:22294817
Tachistoscopic illumination and masking of real scenes.
Chichka, David; Philbeck, John W; Gajewski, Daniel A
2015-03-01
Tachistoscopic presentation of scenes has been valuable for studying the emerging properties of visual scene representations. The spatial aspects of this work have generally been focused on the conceptual locations (e.g., next to the refrigerator) and directional locations of objects in 2-D arrays and/or images. Less is known about how the perceived egocentric distance of objects develops. Here we describe a novel system for presenting brief glimpses of a real-world environment, followed by a mask. The system includes projectors with mechanical shutters for projecting the fixation and masking images, a set of LED floodlights for illuminating the environment, and computer-controlled electronics to set the timing and initiate the process. Because a real environment is used, most visual distance and depth cues can be manipulated using traditional methods. The system is inexpensive, robust, and its components are readily available in the marketplace. This article describes the system and the timing characteristics of each component. We verified the system's ability to control exposure to time scales as low as a few milliseconds.
Masking reduces orientation selectivity in rat visual cortex
Alwis, Dasuni S.; Richards, Katrina L.
2016-01-01
In visual masking the perception of a target stimulus is impaired by a preceding (forward) or succeeding (backward) mask stimulus. The illusion is of interest because it allows uncoupling of the physical stimulus, its neuronal representation, and its perception. To understand the neuronal correlates of masking, we examined how masks affected the neuronal responses to oriented target stimuli in the primary visual cortex (V1) of anesthetized rats (n = 37). Target stimuli were circular gratings with 12 orientations; mask stimuli were plaids created as a binarized sum of all possible target orientations. Spatially, masks were presented either overlapping or surrounding the target. Temporally, targets and masks were presented for 33 ms, but the stimulus onset asynchrony (SOA) of their relative appearance was varied. For the first time, we examine how spatially overlapping and center-surround masking affect orientation discriminability (rather than visibility) in V1. Regardless of the spatial or temporal arrangement of stimuli, the greatest reductions in firing rate and orientation selectivity occurred for the shortest SOAs. Interestingly, analyses conducted separately for transient and sustained target response components showed that changes in orientation selectivity do not always coincide with changes in firing rate. Given the near-instantaneous reductions observed in orientation selectivity even when target and mask do not spatially overlap, we suggest that monotonic visual masking is explained by a combination of neural integration and lateral inhibition. PMID:27535373
Psychophysiological responses to masked auditory stimuli.
Borgeat, F; Elie, R; Chaloult, L; Chabot, R
1985-02-01
Psychophysiological responses to masked auditory verbal stimuli of increasing intensities were studied in twenty healthy women. Two experimental sessions corresponding to two stimulation contents (neutral or emotional) were conducted. At each session, two different sets of instructions (attending or not attending to stimuli) were used successively. Verbal stimuli, masked by a 40-dB white noise, were presented to the subject at increasing intensities by increments of 5 dB starting at 0 dB. At each increment, frontal EMG, skin conductance and heart rate were recorded. The data were submitted to analyses of variance and covariance. Psychophysiological responses to stimuli below the thresholds of identification and detection were observed. The instruction not to attend the stimuli modified the patterns of physiological responses. The effect of the affective content of the stimuli on responses was stronger when not attending. The results show the possibility of psychophysiological responses to masked auditory stimuli and suggests that psychophysiological parameters can constitute objective and useful measures for research in auditory subliminal perception.
Relationship of extinction to perceptual thresholds for single stimuli.
Meador, K J; Ray, P G; Day, L J; Loring, D W
2001-04-24
To demonstrate the effects of target stimulus intensity on extinction to double simultaneous stimuli. Attentional deficits contribute to extinction in patients with brain lesions, but extinction (i.e., masking) can also be produced in healthy subjects. The relationship of extinction to perceptual thresholds for single stimuli remains uncertain. Brief electrical pulses were applied simultaneously to the left and right index fingers of 16 healthy volunteers (8 young and 8 elderly adults) and 4 patients with right brain stroke (RBS). The stimulus to be perceived (i.e., target stimulus) was given at the lowest perceptual threshold to perceive any single stimulus (i.e., Minimal) and at the threshold to perceive 100% of single stimuli. The mask stimulus (i.e., stimulus given to block the target) was applied to the contralateral hand at intensities just below discomfort. Extinction was less for target stimuli at 100% than Minimal threshold for healthy subjects. Extinction of left targets was greater in patients with RBS than elderly control subjects. Left targets were extinguished less than right in healthy subjects. In contrast, the majority of left targets were extinguished in patients with RBS even when right mask intensity was reduced below right 100% threshold for single stimuli. RBS patients had less extinction for right targets despite having greater left mask - threshold difference than control subjects. In patients with RBS, right "targets" at 100% threshold extinguished left "masks" (20%) almost as frequently as left masks extinguished right targets (32%). Subtle changes in target intensity affect extinction in healthy adults. Asymmetries in mask and target intensities (relative to single-stimulus perceptual thresholds) affect extinction in RBS patients less for left targets but more for right targets as compared with control subjects.
Optimal mask characterization by Surrogate Wafer Print (SWaP) method
NASA Astrophysics Data System (ADS)
Kimmel, Kurt R.; Hoellein, Ingo; Peters, Jan Hendrick; Ackmann, Paul; Connolly, Brid; West, Craig
2008-10-01
Traditionally, definition of mask specifications is done completely by the mask user, while characterization of the mask relative to the specifications is done completely by the mask maker. As the challenges of low-k1 imaging continue to grow in scope of designs and in absolute complexity, the inevitable partnership between wafer lithographers and mask makers has strengthened as well. This is reflected in the jointly owned mask facilities and device manufacturers' continued maintenance of fully captive mask shops which foster the closer mask-litho relationships. However, while some device manufacturers have leveraged this to optimize mask specifications before the mask is built and, therefore, improve mask yield and cost, the opportunity for post-fabrication partnering on mask characterization is more apparent and compelling. The Advanced Mask Technology Center (AMTC) has been investigating the concept of assessing how a mask images, rather than the mask's physical attributes, as a technically superior and lower-cost method to characterize a mask. The idea of printing a mask under its intended imaging conditions, then characterizing the imaged wafer as a surrogate for traditional mask inspections and measurements represents the ultimate method to characterize a mask's performance, which is most meaningful to the user. Surrogate wafer print (SWaP) is already done as part of leading-edge wafer fab mask qualification to validate defect and dimensional performance. In the past, the prospect of executing this concept has generally been summarily discarded as technically untenable and logistically intractable. The AMTC published a paper at BACUS 2007 successfully demonstrating the performance of SWaP for the characterization of defects as an alternative to traditional mask inspection [1]. It showed that this concept is not only feasible, but, in some cases, desirable. This paper expands on last year's work at AMTC to assess the full implementation of SWaP as an enhancement to mask characterization quality including defectivity, dimensional control, pattern fidelity, and in-plane distortion. We present a thorough analysis of both the technical and logistical challenges coupled with an objective view of the advantages and disadvantages from both the technical and financial perspectives. The analysis and model used by the AMTC will serve to provoke other mask shops to prepare their own analyses then consider this new paradigm for mask characterization and qualification.
Cepeda, Nicholas J.; Blackwell, Katharine A.; Munakata, Yuko
2012-01-01
The rate at which people process information appears to influence many aspects of cognition across the lifespan. However, many commonly accepted measures of “processing speed” may require goal maintenance, manipulation of information in working memory, and decision-making, blurring the distinction between processing speed and executive control and resulting in overestimation of processing-speed contributions to cognition. This concern may apply particularly to studies of developmental change, as even seemingly simple processing speed measures may require executive processes to keep children and older adults on task. We report two new studies and a re-analysis of a published study, testing predictions about how different processing speed measures influence conclusions about executive control across the life span. We find that the choice of processing speed measure affects the relationship observed between processing speed and executive control, in a manner that changes with age, and that choice of processing speed measure affects conclusions about development and the relationship among executive control measures. Implications for understanding processing speed, executive control, and their development are discussed. PMID:23432836
The influence of viewing conditions on radiological diagnosis of periapical inflammation.
Patel, N; Rushton, V E; Macfarlane, T V; Horner, K
2000-07-08
To determine the effect of viewing conditions upon diagnosis of early periapical inflammatory pathosis on intra-oral radiographs, and to examine the effect of observer experience upon diagnostic performance in this task. 50 observers examined 18 periapical radiographs using three different viewing conditions (room lighting; viewing box; viewing box with x2 magnification and masking). Their diagnoses were compared with an 'expert' diagnosis provided by repeated viewings of the films by two dental radiologists. Sensitivities and specificities were determined. When 'ideal' viewing conditions were used, optimal sensitivity (78%) and specificity (78%) were obtained. Use of a viewing box was associated with significantly higher specificity than the use of room lighting (P = 0.0016). Use of masking and x2 magnification was associated with significantly higher sensitivity than a viewing box alone (P = 0.004). There were few significant differences in diagnostic performance between observers, but qualified dental staff had significantly higher specificities than 4th year (P = 0.01) and 5th year (P = 0.01) students when a viewing box was used alone. This study on early periapical inflammatory pathosis gives support to guidelines which recommend the use of a viewing box, x2 magnification and masking for interpreting intra-oral radiographs. It also suggests that observer experience may influence interpretation of early periapical pathosis.
Automated aerial image based CD metrology initiated by pattern marking with photomask layout data
NASA Astrophysics Data System (ADS)
Davis, Grant; Choi, Sun Young; Jung, Eui Hee; Seyfarth, Arne; van Doornmalen, Hans; Poortinga, Eric
2007-05-01
The photomask is a critical element in the lithographic image transfer process from the drawn layout to the final structures on the wafer. The non-linearity of the imaging process and the related MEEF impose a tight control requirement on the photomask critical dimensions. Critical dimensions can be measured in aerial images with hardware emulation. This is a more recent complement to the standard scanning electron microscope measurement of wafers and photomasks. Aerial image measurement includes non-linear, 3-dimensional, and materials effects on imaging that cannot be observed directly by SEM measurement of the mask. Aerial image measurement excludes the processing effects of printing and etching on the wafer. This presents a unique contribution to the difficult process control and modeling tasks in mask making. In the past, aerial image measurements have been used mainly to characterize the printability of mask repair sites. Development of photomask CD characterization with the AIMS TM tool was motivated by the benefit of MEEF sensitivity and the shorter feedback loop compared to wafer exposures. This paper describes a new application that includes: an improved interface for the selection of meaningful locations using the photomask and design layout data with the Calibre TM Metrology Interface, an automated recipe generation process, an automated measurement process, and automated analysis and result reporting on a Carl Zeiss AIMS TM system.
Peirovifar, Ali; Eydi, Mahmood; Mirinejhad, Mir Mousa; Mahmoodpoor, Ata; Mohammadi, Afsaneh; EJ Golzari, Samad
2013-01-01
Objective: To compare the postoperative complications between Laryngeal Mask Airway (LMA) and endotracheal tube (ETT) during low-flow anesthesia with controlled ventilation. Methodology: Eighty adult Patients with ASA class I or II were randomly allocated into two forty-patient groups (ETT or LMA). Cuff pressure was monitored during anesthesia. After high uptake period, fresh gas flow (FGF) was decreased to 1 lit/min and isoflurane set to 1%. Monitoring during anesthesia included non-invasive blood pressure, ECG, ETCO2 and pulse oximetry. System leakage (>100 ml/min), rebreathing and any attempt to increase FGF to overcome the leak were monitored during anesthesia. Later, patients were extubated and transferred to Post Anesthesia Care Unit (PACU). In PACU, the incidence of sore throat, cough, difficulty in swallowing and shivering was monitored for all patients. Results: Leakage was observed in two and three cases in ETT and LMA groups respectively (P>0.05). Postoperative cough, sore throat and difficulty in swallowing were significantly less in LMA than ETT group. No significant difference was observed regarding ETCo2 values between 2 groups. Conclusion: If careful measures regarding insertion techniques, correct LMA position and routine monitoring of LMA cuff pressure are taken, LMA can be used as a safe alternative with lower incidence of post operation complication compared with ETT during low-flow controlled anesthesia with modern anesthetic machines. PMID:24353586
Mask_explorer: A tool for exploring brain masks in fMRI group analysis.
Gajdoš, Martin; Mikl, Michal; Mareček, Radek
2016-10-01
Functional magnetic resonance imaging (fMRI) studies of the human brain are appearing in increasing numbers, providing interesting information about this complex system. Unique information about healthy and diseased brains is inferred using many types of experiments and analyses. In order to obtain reliable information, it is necessary to conduct consistent experiments with large samples of subjects and to involve statistical methods to confirm or reject any tested hypotheses. Group analysis is performed for all voxels within a group mask, i.e. a common space where all of the involved subjects contribute information. To our knowledge, a user-friendly interface with the ability to visualize subject-specific details in a common analysis space did not yet exist. The purpose of our work is to develop and present such interface. Several pitfalls have to be avoided while preparing fMRI data for group analysis. One such pitfall is spurious non-detection, caused by inferring conclusions in the volume of a group mask that has been corrupted due to a preprocessing failure. We describe a MATLAB toolbox, called the mask_explorer, designed for prevention of this pitfall. The mask_explorer uses a graphical user interface, enables a user-friendly exploration of subject masks and is freely available. It is able to compute subject masks from raw data and create lists of subjects with potentially problematic data. It runs under MATLAB with the widely used SPM toolbox. Moreover, we present several practical examples where the mask_explorer is usefully applied. The mask_explorer is designed to quickly control the quality of the group fMRI analysis volume and to identify specific failures related to preprocessing steps and acquisition. It helps researchers detect subjects with potentially problematic data and consequently enables inspection of the data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D
2017-01-01
We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; P<.001). The intraoral mask resulted in greater received minute volume received compared with conventional cuffed face mask during ventilation with a 1-handed mask seal in a cadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Continuous positive airway pressure with helmet versus mask in infants with bronchiolitis: an RCT.
Chidini, Giovanna; Piastra, Marco; Marchesi, Tiziana; De Luca, Daniele; Napolitano, Luisa; Salvo, Ida; Wolfler, Andrea; Pelosi, Paolo; Damasco, Mirco; Conti, Giorgio; Calderini, Edoardo
2015-04-01
Noninvasive continuous positive airway pressure (CPAP) is usually applied with a nasal or facial mask to treat mild acute respiratory failure (ARF) in infants. A pediatric helmet has now been introduced in clinical practice to deliver CPAP. This study compared treatment failure rates during CPAP delivered by helmet or facial mask in infants with respiratory syncytial virus-induced ARF. In this multicenter randomized controlled trial, 30 infants with respiratory syncytial virus-induced ARF were randomized to receive CPAP by helmet (n = 17) or facial mask (n = 13). The primary endpoint was treatment failure rate (defined as due to intolerance or need for intubation). Secondary outcomes were CPAP application time, number of patients requiring sedation, and complications with each interface. Compared with the facial mask, CPAP by helmet had a lower treatment failure rate due to intolerance (3/17 [17%] vs 7/13 [54%], P = .009), and fewer infants required sedation (6/17 [35%] vs 13/13 [100%], P = .023); the intubation rates were similar. In successfully treated patients, CPAP resulted in better gas exchange and breathing pattern with both interfaces. No major complications due to the interfaces occurred, but CPAP by mask had higher rates of cutaneous sores and leaks. These findings confirm that CPAP delivered by helmet is better tolerated than CPAP delivered by facial mask and requires less sedation. In addition, it is safe to use and free from adverse events, even in a prolonged clinical setting. Copyright © 2015 by the American Academy of Pediatrics.
High-emulation mask recognition with high-resolution hyperspectral video capture system
NASA Astrophysics Data System (ADS)
Feng, Jiao; Fang, Xiaojing; Li, Shoufeng; Wang, Yongjin
2014-11-01
We present a method for distinguishing human face from high-emulation mask, which is increasingly used by criminals for activities such as stealing card numbers and passwords on ATM. Traditional facial recognition technique is difficult to detect such camouflaged criminals. In this paper, we use the high-resolution hyperspectral video capture system to detect high-emulation mask. A RGB camera is used for traditional facial recognition. A prism and a gray scale camera are used to capture spectral information of the observed face. Experiments show that mask made of silica gel has different spectral reflectance compared with the human skin. As multispectral image offers additional spectral information about physical characteristics, high-emulation mask can be easily recognized.
ERIC Educational Resources Information Center
van Gaal, Simon; Ridderinkhof, K. Richard; van den Wildenberg, Wery P. M.; Lamme, Victor A. F.
2009-01-01
Theories about the functional relevance of consciousness commonly posit that higher order cognitive control functions, such as response inhibition, require consciousness. To test this assertion, the authors designed a masked stop-signal paradigm to examine whether response inhibition could be triggered and initiated by masked stop signals, which…
NASA Astrophysics Data System (ADS)
Connors Chen, Betsy
2013-02-01
LightLeaves is an installation combining leaf shaped, white light reflection holograms of landscape images with a special kinetic lighting device that houses a lamp and moving leaf shaped masks. The masks are controlled by an Arduino microcontroller and servomotors that position the masks in front of the illumination source of the holograms. The work is the most recent in a long series of landscapes that combine multi-hologram installations with computer controlled devices that play with the motion of the holograms, the light, sound or other elements in the work. LightLeaves was first exhibited at the Peabody Essex Museum in Salem, Massachusetts in a show titled "Eye Spy: Playing with Perception".
Less is more: Neural activity during very brief and clearly visible exposure to phobic stimuli.
Siegel, Paul; Warren, Richard; Wang, Zhishun; Yang, Jie; Cohen, Don; Anderson, Jason F; Murray, Lilly; Peterson, Bradley S
2017-05-01
Research on automatic processes in fear has emphasized the provocation of fear responses rather than their attenuation. We have previously shown that the repeated presentation of feared images without conscious awareness via backward masking reduces avoidance of a live tarantula in spider-phobic participants. Herein we investigated the neural basis for these adaptive effects of masked exposure. 21 spider-phobic and 21 control participants, identified by a psychiatric interview, fear questionnaire, and approaching a live tarantula, viewed stimuli in each of three conditions: (1) very brief exposure (VBE) to masked images of spiders, severely limited awareness; (2) clearly visible exposure (CVE) to spiders, full awareness; and (3) masked images of flowers (control), severely limited awareness. Only VBE to masked spiders generated neural activity more strongly in phobic than in control participants, within subcortical fear, attention, higher-order language, and vision systems. Moreover, VBE activated regions that support fear processing in phobic participants without causing them to experience fear consciously. Counter-intuitively, CVE to the same spiders generated stronger neural activity in control rather than phobic participants within these and other systems. CVE deactivated regions supporting fear regulation and caused phobic participants to experience fear. CVE-induced activations also correlated with measures of explicit fear ratings, whereas VBE-induced activations correlated with measures of implicit fear (color-naming interference of spider words). These multiple dissociations between the effects of VBE and CVE to spiders suggest that limiting awareness of exposure to phobic stimuli through visual masking paradoxically facilitates their processing, while simultaneously minimizing the experience of fear. Hum Brain Mapp 38:2466-2481, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Liska, Grant M; Lee, Jea-Young; Xu, Kaya; Sanberg, Paul R; Borlongan, Cesario V
2018-05-21
An exaggerated acoustic startle reflex (ASR) is a clinical indicator of anxiety disorders, such as post-traumatic stress disorder (PTSD). Given the prevalence of PTSD following traumatic brain injury (TBI), we studied the effects of TBI on ASR. Adult Sprague Dawley rats exposed to moderate controlled cortical impact injury model of TBI displayed suppression of ASR intensity and sensitivity. As patients with PTSD have been shown to display hyperactive startle responses, the present discrepant observation of TBI-induced suppression of ASR has clinical implications, in that the reduced, instead of elevated, startle response in patients with comorbid TBI/PTSD could be owing to a masking effect of TBI.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.
Pressure effects on the nose by an in-flight oxygen mask during simulated flight conditions.
Schreinemakers, J Rieneke C; Boer, C; van Amerongen, P C G M; Kon, M
2016-12-01
Dutch F-16 fighter pilots experience oxygen mask inflicted nasal trauma, including discomfort, pain, skin abrasions, bruises and bone remodelling. Pressure and shear forces on the nose might contribute to causing these adverse effects. In this study, it was evaluated how flight conditions affected the exerted pressure, and whether shear forces were present. The pressure exerted by the oxygen mask was measured in 20 volunteers by placing pressure sensors on the nose and chin underneath the mask. In the human centrifuge, the effects on the exerted pressure during different flight conditions were evaluated (+3G z , +6G z , +9G z , protocolised head movements, mounted visor or night vision goggles, NVG). The runs were recorded to evaluate if the mask's position changed during the run, which would confirm the presence of shear forces. Head movements increased the median pressure on the nose by 50 mm Hg and on the chin by 37 mm Hg. NVG, a visor and accelerative forces also increased the median pressure on the nose. Pressure drops on the nose were also observed, during mounted NVG (-63 mm Hg). The recordings showed the mask slid downwards, especially during the acceleration phase of the centrifuge run, signifying the presence of shear forces. The exerted pressure by the oxygen mask changes during different flight conditions. Exposure to changing pressures and to shear forces probably contributes to mask-inflicted nasal trauma. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Dynamic mask for producing uniform or graded-thickness thin films
Folta, James A [Livermore, CA
2006-06-13
A method for producing single layer or multilayer films with high thickness uniformity or thickness gradients. The method utilizes a moving mask which blocks some of the flux from a sputter target or evaporation source before it deposits on a substrate. The velocity and position of the mask is computer controlled to precisely tailor the film thickness distribution. The method is applicable to any type of vapor deposition system, but is particularly useful for ion beam sputter deposition and evaporation deposition; and enables a high degree of uniformity for ion beam deposition, even for near-normal incidence of deposition species, which may be critical for producing low-defect multilayer coatings, such as required for masks for extreme ultraviolet lithography (EUVL). The mask can have a variety of shapes, from a simple solid paddle shape to a larger mask with a shaped hole through which the flux passes. The motion of the mask can be linear or rotational, and the mask can be moved to make single or multiple passes in front of the substrate per layer, and can pass completely or partially across the substrate.
Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2.
Wood, Fiona E; Morley, Colin J; Dawson, Jennifer A; Kamlin, C Omar F; Owen, Louise S; Donath, Susan; Davis, Peter G
2008-05-01
Techniques of positioning and holding neonatal face masks vary. Studies have shown that leak at the face mask is common and often substantial irrespective of operator experience. (1) To identify a technique for face mask placement and hold which will minimise mask leak. (2) To investigate the effect of written instruction and demonstration of the identified technique on mask leak for two round face masks. Three experienced neonatologists compared methods of placing and holding face masks to minimise the leak for Fisher & Paykel 60 mm and Laerdal size 0/1 masks. 50 clinical staff gave positive pressure ventilation to a modified manikin designed to measure leak at the face mask. They were provided with written instructions on how to position and hold each mask and then received a demonstration. Face mask leak was measured after each teaching intervention. A technique of positioning and holding the face masks was identified which minimised leak. The mean (SD) mask leaks before instruction, after instruction and after demonstration were 55% (31), 49% (30), 33% (26) for the Laerdal mask and 57% (25), 47% (28), 32% (30) for the Fisher & Paykel mask. There was no significant difference in mask leak between the two masks. Written instruction alone reduced leak by 8.8% (CI 1.4% to 16.2%) for either mask; when combined with a demonstration mask leak was reduced by 24.1% (CI 16.4% to 31.8%). Written instruction and demonstration of the identified optimal technique resulted in significantly reduced face mask leak.
Comparison of face masks in the bag-mask ventilation of a manikin.
Redfern, D; Rassam, S; Stacey, M R; Mecklenburgh, J S
2006-02-01
We conducted a study investigating the effectiveness of four face mask designs in the bag-mask ventilation of a special manikin adapted to simulate a difficult airway. Forty-eight anaesthetists volunteered to bag-mask ventilate the manikin for 3 min with four different face masks. The primary outcome of the study was to calculate mean percentage leak from the face masks over 3 min. Anaesthetists were also asked to rate the face masks using a visual analogue score. The single-use scented intersurgical face mask had the lowest mean leak (20%). This was significantly lower than the mean leak from the single-use, cushioned 7,000 series Air Safety Ltd. face mask (24%) and the reusable silicone Laerdal face mask (27%) but not significantly lower than the mean leak from the reusable anatomical intersurgical face mask (23%). There was a large variation in both performance and satisfaction between anaesthetists with each design. This highlights the importance of having a variety of face masks available for emergency use.
Inhibition of return is not impaired but masked by increased facilitation in schizophrenia patients.
Kalogeropoulou, Fenia; Woodruff, Peter W R; Vivas, Ana B
2015-01-01
When attention is attracted to an irrelevant location, performance on a subsequent target is hindered at that location in relation to novel, not previously attended, locations. This phenomenon is known as inhibition of return (IOR). Previous research has shown that IOR is not observed, or its onset is delayed, in schizophrenia patients. In the present study, the authors tested the hypothesis that IOR may be intact but masked by increased facilitation in schizophrenia patients. To test this hypothesis, they used a procedure that usually reduces or eliminates the early facilitation. In the first experiment, the authors used the typical single-cue IOR task in the group of healthy adults (N = 28) and in a group of schizophrenia patients (N = 32). In the second experiment, they manipulated cue-target discriminability by presenting spatially overlapping cues and targets where the cues were more intense than the targets. In Experiment 1, they did not find significant IOR effects in the group of schizophrenia patients, even with cue-target intervals as long as 3,200 ms. However, in Experiment 2, IOR effects were significant at the 350- and 450-ms cue-target intervals for healthy and patients, respectively. This is the first study that shows that schizophrenia patients can actually show inhibitory effects very similar to healthy controls, even when no help is provided to shift their attention away from the irrelevant location. The authors suggest that inhibition is intact in schizophrenia patients, but it is usually masked by increased facilitation. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Twisted multifilament superconductor
NASA Technical Reports Server (NTRS)
Coles, W. D. (Inventor)
1973-01-01
Masking selected portions of a ribbon and forming an intermetallic compound on the unmasked portions by a controlled diffusion reaction produces a twisted filamentary structure. The masking material prohibits the formation of superconductive material on predetermined areas of the substrate.
Anticipating and controlling mask costs within EDA physical design
NASA Astrophysics Data System (ADS)
Rieger, Michael L.; Mayhew, Jeffrey P.; Melvin, Lawrence S.; Lugg, Robert M.; Beale, Daniel F.
2003-08-01
For low k1 lithography, more aggressive OPC is being applied to critical layers, and the number of mask layers with OPC treatments is growing rapidly. The 130 nm, process node required, on average, 8 layers containing rules- or model-based OPC. The 90 nm node will have 16 OPC layers, of which 14 layers contain aggressive model-based OPC. This escalation of mask pattern complexity, coupled with the predominant use of vector-scan e-beam (VSB) mask writers contributes to the rising costs of advanced mask sets. Writing times for OPC layouts are several times longer than for traditional layouts, making mask exposure the single largest cost component for OPC masks. Lower mask yields, another key factor in higher mask costs, is also aggravated by OPC. Historical mask set costs are plotted below. The initial cost of a 90 nm-node mask set will exceed one million dollars. The relative impact of mask cost on chip depends on how many total wafers are printed with each mask set. For many foundry chips, where unit production is often well below 1000 wafers, mask costs are larger than wafer processing costs. Further increases in NRE may begin to discourage these suppliers' adoption to 90 nm and smaller nodes. In this paper we will outline several alternatives for reducing mask costs by strategically leveraging dimensional margins. Dimensional specifications for a particular masking layer usually are applied uniformly to all features on that layer. As a practical matter, accuracy requirements on different features in the design may vary widely. Take a polysilicon layer, for example: global tolerance specifications for that layer are driven by the transistor-gate requirements; but these parameters over-specify interconnect feature requirements. By identifying features where dimensional accuracy requirements can be reduced, additional margin can be leveraged to reduce OPC complexity. Mask writing time on VSB tools will drop in nearly direct proportion to reduce shot count. By inspecting masks with reference to feature-dependent margins, instead of uniform specifications, mask yield can be effectively increased further reducing delivered mask expense.
NASA Technical Reports Server (NTRS)
Shiffman, Smadar
2004-01-01
Automated cloud detection and tracking is an important step in assessing global climate change via remote sensing. Cloud masks, which indicate whether individual pixels depict clouds, are included in many of the data products that are based on data acquired on- board earth satellites. Many cloud-mask algorithms have the form of decision trees, which employ sequential tests that scientists designed based on empirical astrophysics studies and astrophysics simulations. Limitations of existing cloud masks restrict our ability to accurately track changes in cloud patterns over time. In this study we explored the potential benefits of automatically-learned decision trees for detecting clouds from images acquired using the Advanced Very High Resolution Radiometer (AVHRR) instrument on board the NOAA-14 weather satellite of the National Oceanic and Atmospheric Administration. We constructed three decision trees for a sample of 8km-daily AVHRR data from 2000 using a decision-tree learning procedure provided within MATLAB(R), and compared the accuracy of the decision trees to the accuracy of the cloud mask. We used ground observations collected by the National Aeronautics and Space Administration Clouds and the Earth s Radiant Energy Systems S COOL project as the gold standard. For the sample data, the accuracy of automatically learned decision trees was greater than the accuracy of the cloud masks included in the AVHRR data product.
NASA Astrophysics Data System (ADS)
Hosono, Kunihiro; Kato, Kokoro
2008-10-01
This is a report on a panel discussion organized in Photomask Japan 2008, where the challenges about "Mask Complexities, Cost, and Cycle Time in 32-nm System LSI Generation" were addressed to have a look over the possible solutions from the standpoints of chipmaker, commercial mask shop, DA tool vendor and equipments makers. The wrap-up is as follows: Mask complexities justify the mask cost, while the acceptable increase rate of 32nm-mask cost significantly differs between mask suppliers or users side. The efficiency progress by new tools or DFM has driven their cycle-time reductions. Mask complexities and cost will be crucial issues prior to cycle time, and there seems to be linear correlation between them. Controlling complexity and cycle time requires developing a mix of advanced technologies, and especially for cost reduction, shot prices in writers and processing rates in inspection tools have been improved remarkably by tool makers. In addition, activities of consortium in Japan (Mask D2I) are expected to enhance the total optimization of mask design, writing and inspection. The cycle-time reduction potentially drives the lowering of mask cost, and, on the other, the pattern complexities and tighter mask specifications get in the way to 32nm generation as well as the nano-economics and market challenges. There are still many difficult problems in mask manufacturing now, and we are sure to go ahead to overcome a 32nm hurdle with the advances of technologies and collaborations by not only technologies but also finance.
Object Substitution Masking: When Does Mask Preview Work?
ERIC Educational Resources Information Center
Lim, Stephen Wee Hun; Chua, Fook K.
2008-01-01
When a target is enclosed by a 4-dot mask that persists after the target disappears, target identification is worse than it is when the mask terminates with the target. This masking effect is attributed to object substitution masking (OSM). Previewing the mask, however, attenuates OSM. This study investigated specific conditions under which mask…
SU-8 negative photoresist for optical mask manufacturing
NASA Astrophysics Data System (ADS)
Bogdanov, Alexei L.
2000-06-01
The requirements for better control, linearity, and uniformity of critical dimension (CD) on photomasks in fabrication of 180 and 150 nm generation devices result in increasing demand for thinner, more etching durable, and more sensitive e-beam resists. Novolac based resists with chemical amplification have been a choice for their sensitivity and stability during etching. However, difficult CD control due to the acid catalyzer diffusion and quite narrow post exposure bake (PEB) process window are some of the major drawbacks of these resists. SU-8 is recently introduced to the market negative photoresist. High sensitivity, fairly good adhesion properties, and relatively simple processing of SU-8 make it a good substitution for novolac based chemically amplified negative e-beam resists in optical mask manufacturing. The replacement of traditional chemically amplified resists by SU- 8 can increase the process latitude and reduce resist costs. Among the obvious drawbacks of SU-8 are the use of solvent- based developer and demand of oxygen plasma for resist removal. In this paper the use of SU-8 for optical mask manufacturing is reported. All steps of resist film preparation, exposure and development are paid a share of attention. Possibilities to use reactive ion etching (RIE) with oxygen in order to increase resist mask contrast are discussed. Special exposure strategy (pattern outlining) was employed to further improve the edge definition. The resist PEB temperature and time were studied to estimate their weight in overall CD control performance. Specially designed test patterns with 0.25 micrometer design rule could be firmly transferred into a chromium layer both by wet etching and ion milling. Influence of exposure dose variation on the pattern CD change was studied.
Nanoimprint wafer and mask tool progress and status for high volume semiconductor manufacturing
NASA Astrophysics Data System (ADS)
Matsuoka, Yoichi; Seki, Junichi; Nakayama, Takahiro; Nakagawa, Kazuki; Azuma, Hisanobu; Yamamoto, Kiyohito; Sato, Chiaki; Sakai, Fumio; Takabayashi, Yukio; Aghili, Ali; Mizuno, Makoto; Choi, Jin; Jones, Chris E.
2016-10-01
Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Jet and Flash* Imprint Lithography (J-FIL*) involves the field-by-field deposition and exposure of a low viscosity resist deposited by jetting technology onto the substrate. The patterned mask is lowered into the fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed, leaving a patterned resist on the substrate. There are many criteria that determine whether a particular technology is ready for wafer manufacturing. Defectivity and mask life play a significant role relative to meeting the cost of ownership (CoO) requirements in the production of semiconductor devices. Hard particles on a wafer or mask create the possibility of inducing a permanent defect on the mask that can impact device yield and mask life. By using material methods to reduce particle shedding and by introducing an air curtain system, the lifetime of both the master mask and the replica mask can be extended. In this work, we report results that demonstrate a path towards achieving mask lifetimes of better than 1000 wafers. On the mask side, a new replication tool, the FPA-1100 NR2 is introduced. Mask replication is required for nanoimprint lithography (NIL), and criteria that are crucial to the success of a replication platform include both particle control, resolution and image placement accuracy. In this paper we discuss the progress made in both feature resolution and in meeting the image placement specification for replica masks.
On Optimizing H. 264/AVC Rate Control by Improving R-D Model and Incorporating HVS Characteristics
NASA Astrophysics Data System (ADS)
Zhu, Zhongjie; Wang, Yuer; Bai, Yongqiang; Jiang, Gangyi
2010-12-01
The state-of-the-art JVT-G012 rate control algorithm of H.264 is improved from two aspects. First, the quadratic rate-distortion (R-D) model is modified based on both empirical observations and theoretical analysis. Second, based on the existing physiological and psychological research findings of human vision, the rate control algorithm is optimized by incorporating the main characteristics of the human visual system (HVS) such as contrast sensitivity, multichannel theory, and masking effect. Experiments are conducted, and experimental results show that the improved algorithm can simultaneously enhance the overall subjective visual quality and improve the rate control precision effectively.
Van-Buendia, Lan B; Allely, Rebekah R; Lassiter, Ronald; Weinand, Christian; Jordan, Marion H; Jeng, James C
2010-01-01
Clinically, the initial blanching in burn scar seen on transparent plastic face mask application seems to diminish with time and movement requiring mask alteration. To date, studies quantifying perfusion with prolonged mask use do not exist. This study used laser Doppler imaging (LDI) to assess perfusion through the transparent face mask and movement in subjects with and without burn over time. Five subjects fitted with transparent face masks were scanned with the LDI on four occasions. The four subjects without burn were scanned in the following manner: 1) no mask, 2) mask on while at rest, 3) mask on with alternating intervals of sustained facial expression and rest, and 4) after mask removal. Images were acquired every 3 minutes throughout the 85-minute study period. The subject with burn underwent a shortened scanning protocol to increase comfort. Each face was divided into five regions of interest for analysis. Compared with baseline, mask application decreased perfusion significantly in all subjects (P < .0001). Perfusion did not change during the rest period. There were no significant differences with changing facial expression in any of the regions of interest. On mask removal, all regions of the face demonstrated a hyperemic effect with the chin (P = .05) and each cheek (P < .0001) reaching statistical significance. Perfusion levels did not return to baseline in the chin and cheeks after 30 minutes of mask removal. Perfusions remain constantly low while wearing the face mask, despite changing facial expressions. Changing facial expressions with the mask on did not alter perfusion. Hyperemic response occurs on removal of the mask. This study exposed methodology and statistical issues worth considering when conducting future research with the face, pressure therapy, and with LDI technology.
Ushigome, Emi; Oyabu, Chikako; Tanaka, Toru; Hasegawa, Goji; Ohnishi, Masayoshi; Tsunoda, Sei; Ushigome, Hidetaka; Yokota, Isao; Nakamura, Naoto; Oda, Yohei; Asano, Mai; Tanaka, Muhei; Yamazaki, Masahiro; Fukui, Michiaki
2018-05-01
The prognostic significance of masked hypertension (MH) on the progression of diabetic nephropathy among patients with type II diabetes is not well documented. We examined the relationship between clinic systolic blood pressure (SBP) and morning home SBP measurements and progression to macroalbuminuria in patients with type II diabetes. We analyzed prospective cohort study data from 712 patients with type II diabetes. We classified the patients into the following four groups according to their clinic (130 mm Hg) and home (125 mm Hg) SBP measurements: controlled blood pressure group, white-coat hypertension group, MH group, and sustained hypertension (SH) group. The patients were instructed to perform triplicate morning and evening blood pressure measurements for 14 consecutive days. During the 2-year follow-up period, 23 patients progressed to macroalbuminuria. The unadjusted odds ratio (95% confidence interval) for progression to macroalbuminuria among the patients with MH was significantly higher than that among the patients with controlled blood pressure (8.89 [1.06-74.88]). No significant relationship was observed between white-coat hypertension or SH and progression to macroalbuminuria. In analyses adjusted for various potential confounders, the adjusted odds ratio for progression to macroalbuminuria in the MH group was more than 8-fold higher than that in the controlled blood pressure group. MH might be a predictor of progression to macroalbuminuria among patients with type II diabetes. This rate of progression is comparable with or greater than the results reported for patients with SH. Copyright © 2018 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Rates of initial acceptance of PAP masks and outcomes of mask switching.
Bachour, Adel; Vitikainen, Pirjo; Maasilta, Paula
2016-05-01
Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms. We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching. Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks. The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.
Novel EUV mask black border suppressing EUV and DUV OoB light reflection
NASA Astrophysics Data System (ADS)
Ito, Shin; Kodera, Yutaka; Fukugami, Norihito; Komizo, Toru; Maruyama, Shingo; Watanabe, Genta; Yoshida, Itaru; Kotani, Jun; Konishi, Toshio; Haraguchi, Takashi
2016-05-01
EUV lithography is the most promising technology for semiconductor device manufacturing of the 10nm node and beyond. The image border is a pattern free dark area around the die on the photomask serving as transition area between the parts of the mask that is shielded from the exposure light by the Reticle Masking (REMA) blades and the die. When printing a die at dense spacing on an EUV scanner, the reflection from the image border overlaps edges of neighboring dies, affecting CD and contrast in this area. This is related to the fact that EUV absorber stack reflects 1-3% of actinic EUV light. To reduce this effect several types of image border with reduced EUV reflectance (<0.05%) have been proposed; such an image border is referred to as a black border. In particular, an etched multilayer type black border was developed; it was demonstrated that CD impact at the edge of a die is strongly reduced with this type of the black border (BB). However, wafer printing result still showed some CD change in the die influenced by the black border reflection. It was proven that the CD shift was caused by DUV Out of Band (OOB) light from the EUV light source. New types of a multilayer etched BB were evaluated and showed a good potential for DUV light suppression. In this study, a novel BB called `Hybrid Black Border' (HBB) has been developed to eliminate EUV and DUV OOB light reflection by applying optical design technique and special micro-fabrication technique. A new test mask with HBB is fabricated without any degradation of mask quality according to the result of CD performance in the main pattern, defectivity and cleaning durability. The imaging performance for N10 imaging structures is demonstrated on NXE:3300B in collaboration with ASML. This result is compared to the imaging results obtained for a mask with the earlier developed BB, and HBB has achieved ~3x improvement; less than 0.2 nm CD changes are observed in the corners of the die. A CD uniformity budget including impact of OOB light in the die edge area is evaluated which shows that the OOB impact from HBB becomes comparable with other CDU contributors in this area. Finally, we state that HBB is a promising technology allowing for CD control at die edges.
Yan, F; Li, J; Wang, H J; Yang, X; Yang, J B; Tu, X J
2018-05-15
Objective: By observing the clinical effect of ultrasound, fiberoptic bronchoscopy and traditional standard in positioning the general anesthesia of laryngeal mask ventilation in elderly patients, the superiority of laryngeal mask positioning with visualization technique of ultrasound and fiberoptic bronchoscope on airway management in elderly patients with general anesthesia was analyzed. Methods: One hundred and twenty cases of elderly patients with general anesthesia of laryngeal mask ventilation from the People's Hospital of Yuyao city from October 2016 to October 2017 were selected and randomly divided into 3 groups( n =40)according to American Society of Anesthesiologists (ASA) grading criteria Ⅰ-Ⅲ. Group A: traditional standard positioning laryngeal mask group. Group B: fiberoptic bronchoscope positioning laryngeal mask group. Group C: ultrasound positioning laryngeal mask group. The general information of sex ratio of male and female, mass, and height, and operation type, operation duration, anaesthesia duration, and modified Mallampati grade were observed and compared among the three groups. The number of successful laryngeal mask ventilation after laryngeal mask placement in 3 groups was observed, the laryngeal mask placement time (T(0)) and the normal ventilation time after adjustment (T(1)) in each group were recorded, and the first success rate of laryngeal mask placement, the success rate after adjusting the positioning, and the success rate of re-placement were calculated. Moreover, the mean peak airway pressure at 5 min after operation, the minimum intrathecal injection gas for minimum ventilation (V(min)), the minimum laryngeal mask intravesical pressure (ICP(min)), and the lowest air pressure for oral and pharyngeal leakage (OLP(min)) were recorded. The airway seal pressure (OLP(60)) and the volume of gas injection (V(60)) when the intravesical pressure was 60 cmH(2)O (1 cmH(2)O=0.098 kPa) were used to record the incidence of postoperative laryngeal mask bleeding, cough, nausea and vomiting, and the incidence of pharyngalgia, odynophagia, hoarseness and other related complications after 24 hours of the operation. Results: There was no significant difference in general information, airway evaluation and anesthesia operation among the three groups (all P >0.05). The incidence of intraoperative laryngeal mask bleeding in group B and C was 7.9% and 2.6% respectively, the incidence of odynophagia at 24 hours after operation was 5.3% and 0 respectively, and the incidence of pharyngalgia and hoarseness was 18.4% and 7.9% respectively, less than that in group A (24.2%, 12.1% and 36.3%). The difference was statistically significant (χ(2)=8.900, 6.880, 9.000, P <0.05). The success rate of adjustment and positioning after the placement of laryngeal mask was 84.2% and 94.7% respectively in group B and C, higher than that in group A of 72.7%, and the difference was statistically significant (χ(2)=6.500, P <0.05). The lowest laryngeal mask intralaryngeal pressure for ventilation in group B and C was (35.39±4.67) cmH(2)O and (32.61±3.22) cmH(2)O, lower than that in group A of (39.30 ± 5.93) cmH(2)O, the intralaryngeal pressure was 60 cmH(2)O, and the airway seal pressure was (25.82±4.48) cmH(2)O and (28.34±6.99) cmH(2)O, higher than that in group A of (22.45±4.98) cmH(2)O, which was significantly different ( F =18.200, 9.720, P <0.05). Conclusions: In elderly patients with general anesthesia, it is feasible to manage the airway by ultrasound or fiberoptic bronchoscopy with laryngeal mask. Ultrasound positioning laryngeal mask improves the accuracy of the intraoperative ventilation, and reduces the incidence of postoperative airway related complications.
Wheeler, Katherine; McKelvey, Wendy; Thorpe, Lorna; Perrin, Megan; Cone, James; Kass, Daniel; Farfel, Mark; Thomas, Pauline; Brackbill, Robert
2007-01-01
Background Studies have consistently documented declines in respiratory health after 11 September 2001 (9/11) among surviving first responders and other World Trade Center (WTC) rescue, recovery, and clean-up workers. Objectives The goal of this study was to describe the risk of newly diagnosed asthma among WTC site workers and volunteers and to characterize its association with WTC site exposures. Methods We analyzed 2003–2004 interview data from the World Trade Center Health Registry for workers who did not have asthma before 9/11 (n = 25,748), estimating the risk of newly diagnosed asthma and its associations with WTC work history, including mask or respirator use. Results Newly diagnosed asthma was reported by 926 workers (3.6%). Earlier arrival and longer duration of work were significant risk factors, with independent dose responses (p < 0.001), as were exposure to the dust cloud and pile work. Among workers who arrived on 11 September, longer delays in the initial use of masks or respirators were associated with increased risk of asthma; adjusted odds ratios ranged from 1.63 [95% confidence interval (CI), 1.03–2.56) for 1 day of delay to 3.44 (95% CI, 1.43–8.25) for 16–40 weeks delay. Conclusions The rate of self-reported newly diagnosed asthma was high in the study population and significantly associated with increased exposure to the WTC disaster site. Although we could not distinguish appropriate respiratory protection from inappropriate, we observed a moderate protective effect of mask or respirator use. The findings underscore the need for adequate and timely distribution of appropriate protective equipment and the enforcement of its use when other methods of controlling respiratory exposures are not feasible. PMID:18007989
Wheeler, Katherine; McKelvey, Wendy; Thorpe, Lorna; Perrin, Megan; Cone, James; Kass, Daniel; Farfel, Mark; Thomas, Pauline; Brackbill, Robert
2007-11-01
Studies have consistently documented declines in respiratory health after 11 September 2001 (9/11) among surviving first responders and other World Trade Center (WTC) rescue, recovery, and clean-up workers. The goal of this study was to describe the risk of newly diagnosed asthma among WTC site workers and volunteers and to characterize its association with WTC site exposures. We analyzed 2003-2004 interview data from the World Trade Center Health Registry for workers who did not have asthma before 9/11 (n = 25,748), estimating the risk of newly diagnosed asthma and its associations with WTC work history, including mask or respirator use. Newly diagnosed asthma was reported by 926 workers (3.6%). Earlier arrival and longer duration of work were significant risk factors, with independent dose responses (p < 0.001), as were exposure to the dust cloud and pile work. Among workers who arrived on 11 September, longer delays in the initial use of masks or respirators were associated with increased risk of asthma; adjusted odds ratios ranged from 1.63 [95% confidence interval (CI), 1.03-2.56) for 1 day of delay to 3.44 (95% CI, 1.43-8.25) for 16-40 weeks delay. The rate of self-reported newly diagnosed asthma was high in the study population and significantly associated with increased exposure to the WTC disaster site. Although we could not distinguish appropriate respiratory protection from inappropriate, we observed a moderate protective effect of mask or respirator use. The findings underscore the need for adequate and timely distribution of appropriate protective equipment and the enforcement of its use when other methods of controlling respiratory exposures are not feasible.
Discrimination of face gender and expression under dual-task conditions.
García-Gutiérrez, Ana; Aguado, Luis; Romero-Ferreiro, Verónica; Pérez-Moreno, Elisa
2017-02-01
In order to test whether expression and gender can be attended to simultaneously without a cost in accuracy four experiments were carried out using a dual gender-expression task with male and female faces showing different emotional expressions that were backward masked by emotionally neutral faces. In the dual-facial condition the participants had to report both the gender and the expression of the targets. In two control conditions the participant reported either the gender or the expression of the face and indicated whether a surrounding frame was continuous or discontinuous. In Experiments 1-3, with angry and happy targets, asymmetric interference was observed. Gender discrimination, but no expression discrimination, was impaired in the dual-facial condition compared to the corresponding control. This effect was obtained with a between-subjects design in Experiment 1, with a within-subjects design in Experiment 2, and with androgynous face masks in Experiment 3. In Experiments 4a and 4b different target combinations were tested. No decrement of performance in the dual-facial task was observed for either gender or expression discrimination with fearful-disgusted (Experiment 4a) or fearful-happy faces (Experiment 4b). We conclude that the ability to attend simultaneously to gender and expression cues without a decrement in performance depends on the specific combination of expressions to be differentiated between. Happy and angry expressions are usually directed at the perceiver and command preferential attention. Under conditions of restricted viewing such as those of the present study, discrimination of these expressions is prioritized leading to impaired discrimination of other facial properties such as gender.
Fabless company mask technology approach: fabless but not fab-careless
NASA Astrophysics Data System (ADS)
Hisamura, Toshiyuki; Wu, Xin
2009-10-01
There are two different foundry-fabless working models in the aspect of mask. Some foundries have in-house mask facility while others contract with merchant mask vendors. Significant progress has been made in both kinds of situations. Xilinx as one of the pioneers of fabless semiconductor companies has been continually working very closely with both merchant mask vendors and mask facilities of foundries in past many years, contributed well in both technology development and benefited from corporations. Our involvement in manufacturing is driven by the following three elements: The first element is to understand the new fabrication and mask technologies and then find a suitable design / layout style to better utilize these new technologies and avoid potential risks. Because Xilinx has always been involved in early stage of advanced technology nodes, this early understanding and adoption is especially important. The second element is time to market. Reduction in mask and wafer manufacturing cycle-time can ensure faster time to market. The third element is quality. Commitment to quality is our highest priority for our customers. We have enough visibility on any manufacturing issues affecting the device functionality. Good correlation has consistently been observed between FPGA speed uniformity and the poly mask Critical Dimension (CD) uniformity performance. To achieve FPGA speed uniformity requirement, the manufacturing process as well as the mask and wafer CD uniformity has to be monitored. Xilinx works closely with the wafer foundries and mask suppliers to improve productivity and the yield from initial development stage of mask making operations. As an example, defect density reduction is one of the biggest challenges for mask supplier in development stage to meet the yield target satisfying the mask cost and mask turn-around-time (TAT) requirement. Historically, masks were considered to be defect free but at these advanced process nodes, that assumption no longer holds true. There is a need to be flexible enough on unrepairable defect at early stage but also a need for efficient risk management system on mask defect waivers. Mask defects are often waived in low design criticality area in favor of scrapping the mask and delaying the mask and wafer schedule. Xilinx's involvement in mask manufacturing has contributed significantly to our success in past many nodes and will continue.
NASA Technical Reports Server (NTRS)
Carroll, M. L.; DiMiceli, C. M.; Townshend, J. R. G.; Sohlberg, R. A.; Elders, A. I.; Devadiga, S.; Sayer, A. M.; Levy, R. C.
2016-01-01
Data from the Moderate Resolution Imaging Spectro-radiometer (MODIS)on-board the Earth Observing System Terra and Aqua satellites are processed using a land water mask to determine when an algorithm no longer needs to be run or when an algorithm needs to follow a different pathway. Entering the fourth reprocessing (Collection 6 (C6)) the MODIS team replaced the 1 km water mask with a 500 m water mask for improved representation of the continental surfaces. The new water mask represents more small water bodies for an overall increase in water surface from 1 to 2 of the continental surface. While this is still a small fraction of the overall global surface area the increase is more dramatic in certain areas such as the Arctic and Boreal regions where there are dramatic increases in water surface area in the new mask. MODIS products generated by the on-going C6 reprocessing using the new land water mask show significant impact in areas with high concentrations of change in the land water mask. Here differences between the Collection 5 (C5) and C6 water masks and the impact of these differences on the MOD04 aerosol product and the MOD11 land surface temperature product are shown.
NASA Astrophysics Data System (ADS)
Ohnuma, Hidetoshi; Kawahira, Hiroichi
1998-09-01
An automatic alternative phase shift mask (PSM) pattern layout tool has been newly developed. This tool is dedicated for embedded DRAM in logic device to shrink gate line width with improving line width controllability in lithography process with a design rule below 0.18 micrometers by the KrF excimer laser exposure. The tool can crete Levenson type PSM used being coupled with a binary mask adopting a double exposure method for positive photo resist. By using graphs, this tool automatically creates alternative PSM patterns. Moreover, it does not give any phase conflicts. By adopting it to actual embedded DRAM in logic cells, we have provided 0.16 micrometers gate resist patterns at both random logic and DRAM areas. The patterns were fabricated using two masks with the double exposure method. Gate line width has been well controlled under a practical exposure-focus window.
Collinear masking effect in visual search is independent of perceptual salience.
Jingling, Li; Lu, Yi-Hui; Cheng, Miao; Tseng, Chia-Huei
2017-07-01
Searching for a target in a salient region should be easier than looking for one in a nonsalient region. However, we previously discovered a contradictory phenomenon in which a local target in a salient structure was more difficult to find than one in the background. The salient structure was constructed of orientation singletons aligned to each other to form a collinear structure. In the present study, we undertake to determine whether such a masking effect was a result of salience competition between a global structure and the local target. In the first 3 experiments, we increased the salience value of the local target with the hope of adding to its competitive advantage and eventually eliminating the masking effect; nevertheless, the masking effect persisted. In an additional 2 experiments, we reduced salience of the global collinear structure by altering the orientation of the background bars and the masking effect still emerged. Our salience manipulations were validated by a controlled condition in which the global structure was grouped noncollinearly. In this case, local target salience increase (e.g., onset) or global distractor salience reduction (e.g., randomized flanking orientations) effectively removed the facilitation effect of the noncollinear structure. Our data suggest that salience competition is unlikely to explain the collinear masking effect, and other mechanisms such as contour integration, border formation, or the crowding effect may be prospective candidates for further investigation.
ERIC Educational Resources Information Center
Poon, Wai-Yin; Wong, Yuen-Kwan
2004-01-01
This study uses a Cook's distance type diagnostic statistic to identify unusual observations in a data set that unduly influence the estimation of a covariance matrix. Similar to many other deletion-type diagnostic statistics, this proposed measure is susceptible to masking or swamping effect in the presence of several unusual observations. In…
The retention and disruption of color information in human short-term visual memory.
Nemes, Vanda A; Parry, Neil R A; Whitaker, David; McKeefry, Declan J
2012-01-27
Previous studies have demonstrated that the retention of information in short-term visual perceptual memory can be disrupted by the presentation of masking stimuli during interstimulus intervals (ISIs) in delayed discrimination tasks (S. Magnussen & W. W. Greenlee, 1999). We have exploited this effect in order to determine to what extent short-term perceptual memory is selective for stimulus color. We employed a delayed hue discrimination paradigm to measure the fidelity with which color information was retained in short-term memory. The task required 5 color normal observers to discriminate between spatially non-overlapping colored reference and test stimuli that were temporally separated by an ISI of 5 s. The points of subjective equality (PSEs) on the resultant psychometric matching functions provided an index of performance. Measurements were made in the presence and absence of mask stimuli presented during the ISI, which varied in hue around the equiluminant plane in DKL color space. For all reference stimuli, we found a consistent mask-induced, hue-dependent shift in PSE compared to the "no mask" conditions. These shifts were found to be tuned in color space, only occurring for a range of mask hues that fell within bandwidths of 29-37 deg. Outside this range, masking stimuli had little or no effect on measured PSEs. The results demonstrate that memory masking for color exhibits selectivity similar to that which has already been demonstrated for other visual attributes. The relatively narrow tuning of these interference effects suggests that short-term perceptual memory for color is based on higher order, non-linear color coding. © ARVO
Cavaliere, F; Conti, G; Costa, R; Spinazzola, G; Proietti, R; Sciuto, A; Masieri, S
2008-01-01
We measured noise intensity and perceived noisiness during continuous positive airway pressure (CPAP) performed with two interfaces (face-mask, helmet) and four delivery systems. Eight healthy volunteers received CPAP in random order with: two systems provided with a flow generator using the Venturi effect and a mechanical expiratory valve (A: Venturi, Starmed; B: Whisperflow-2, Caradyne Ltd); one 'free-flow' system provided with high flow O(2) and air flowmeters, an inspiratory gas reservoir, and a water valve (C: CF800, Drägerwerk, AG); and a standard mechanical ventilator (Servoventilator 300, Siemens-Elema). Systems A, B, and C were tested with a face-mask and a helmet at a CPAP value of 10 cm H(2)O; the mechanical ventilator was only tested with the face mask. Noise intensity was measured with a sound-level meter. After each test, participants scored noisiness on a visual analog scale (VAS). The noise levels measured ranged from 57+/-11 dBA (mechanical ventilator plus mask) to 93+/-1 and 94+/-2 dBA (systems A and B plus helmet) and were significantly affected by CPAP systems (A and B noisier than C and D) and interfaces (helmet CPAP noisier than mask CPAP). Subjective evaluation showed that systems A and B plus helmet were perceived as noisier than system C plus mask or helmet. Maximum noise levels observed in this study may potentially cause patient discomfort. Less noisy CPAP systems (not using Venturi effect) and interfaces (facial mask better than helmet) should be preferred, particularly for long or nocturnal treatments.
Posthypnotic suggestion alters conscious color perception in an automatic manner.
Kallio, Sakari; Koivisto, Mika
2013-01-01
The authors studied whether a posthypnotic suggestion to see a brief, masked target as gray can change the color experience of a hypnotic virtuoso. The visibility of the target was manipulated by varying the delay between the target and the mask that followed it. The virtuoso's subjective reports indicated that her conscious color experience was altered already at short delays between the target and the subsequent mask. The virtuoso's objectively measured pattern of responding under posthypnotic suggestion could not be mimicked either by control participants nor the virtuoso herself. Due to posthypnotic amnesia, the virtuoso was unaware of suggestions given during hypnosis. Importantly, the virtuoso could not alter her color perception without a hypnotic suggestion. These results suggest that hypnosis can affect even a highly automatic process such as color perception.
Chughtai, Abrar Ahmad; Seale, Holly; Chi Dung, Tham; Maher, Lisa; Nga, Phan Thi; MacIntyre, C Raina
2015-01-01
This study aimed to examine the knowledge, attitudes, and practices towards the use of facemasks among hospital-based health care workers (HCWs) in Hanoi, Vietnam. A qualitative study incorporating 20 focus groups was conducted between August 2010 and May 2011. HCWs from 7 hospitals in Vietnam were invited to participate. Issues associated with the availability of facemasks (medical and cloth masks) and respirators was the strongest theme to emerge from the discussion. Participants reported that it is not unusual for some types of facemasks to be unavailable during nonemergency periods. It was highlighted that the use of facemasks and respirators is not continuous, but rather is limited to selected situations, locations, and patients. Reuse of facemasks and respirators is also common in some settings. Finally, some participants reported believing that the reuse of facemasks, particularly cloth masks, is safe, whereas others believed that the reuse of masks put staff at risk of infection. In low and middle-income countries, access to appropriate levels of personal protective equipment may be restricted owing to competing demands for funding in hospital settings. It is important that issues around reuse and extended use of medical masks/respirators and decontamination of cloth masks are addressed in policy documents to minimize the risk of infection. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Baldwin, Alex S.; Baker, Daniel H.; Hess, Robert F.
2016-01-01
The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system’s input has on its output one can estimate the variance of this internal noise. By applying this simple “linear amplifier” model to the human visual system, one can entirely explain an observer’s detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system’s internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity). Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF). We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies. PMID:26953796
Cheung, D; Mian, Q; Cheung, P-Y; O'Reilly, M; Aziz, K; van Os, S; Pichler, G; Schmölzer, G M
2015-07-01
If an infant fails to initiate spontaneous breathing after birth, international guidelines recommend a positive pressure ventilation (PPV). However, PPV by face mask is frequently inadequate because of leak between the face and mask. Despite a variety of available face masks, none have been prospectively compared in a randomized fashion. We aimed to evaluate and compare leak between two commercially available round face masks (Fisher & Paykel (F&P) and Laerdal) in preterm infants <33 weeks gestational age in the delivery room. Infants born at the Royal Alexandra Hospital from April to September 2013 at <33 weeks gestational age who received mask PPV in the delivery room routinely had a flow sensor placed between the mask and T-piece resuscitator. Infants were randomly assigned to receive PPV with either a F&P or Laerdal face mask. All resuscitators were trained in the use of both face masks. We compared mask leak, airway pressures, tidal volume and ventilation rate between the two groups. Fifty-six preterm infants (n=28 in each group) were enrolled; mean±s.d. gestational age 28±3 weeks; birth weight 1210±448 g; and 30 (52%) were male. Apgar scores at 1 and 5 min were 5±3 and 7±2, respectively. Infants randomized to the F&P face mask and Laerdal face mask had similar mask leak (30 (25-38) versus 35 (24-46)%, median (interquartile range), respectively, P=0.40) and tidal volume (7.1 (4.9-8.9) versus 6.6 (5.2-8.9) ml kg(-1), P=0.69) during PPV. There were no significant differences in ventilation rate, inflation time or airway pressures between groups. The use of either face mask during PPV in the delivery room yields similar mask leak in preterm infants <33 weeks gestational age.
Beecroft, Jaime M; Hanly, Patrick J
2006-01-01
BACKGROUND: The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small ‘diffuser’ to concentrate and direct oxygen toward the mouth and nose. The authors hypothesized that this unique design would enable the OxyMask to deliver oxygen more efficiently than a Venturi mask (Hudson RCI, USA) in patients with chronic hypoxemia. METHODS: Oxygen-dependent patients with chronic, stable respiratory disease were recruited to compare the OxyMask and Venturi mask in a randomized, single-blind, cross-over design. Baseline blood oxygen saturation (SaO2) was established breathing room air, followed in a random order by supplemental oxygen through the OxyMask or Venturi mask. Oxygen delivery was titrated to maintain SaO2 4% to 5% and 8% to 9% above baseline for two separate 30 min periods of stable breathing. Oxygen flow rate, partial pressure of inspired and expired oxygen (PO2) and carbon dioxide (PCO2), minute ventilation, heart rate, nasal and oral breathing, SaO2 and transcutaneous PCO2 were collected continuously. The study was repeated following alterations to the OxyMask design, which improved clearance of carbon dioxide. RESULTS: Thirteen patients, aged 28 to 79 years, were studied initially using the original OxyMask. Oxygen flow rate was lower, inspired PO2 was higher and expired PO2 was lower while using the OxyMask. Minute ventilation and inspired and expired PCO2 were significantly higher while using the OxyMask, whereas transcutaneous PCO2, heart rate and the ratio of nasal to oral breathing did not change significantly throughout the study. Following modification of the OxyMask, 13 additional patients, aged 18 to 79 years, were studied using the same protocol. The modified OxyMask provided a higher inspired PO2 at a lower flow rate, without evidence of carbon dioxide retention. CONCLUSIONS: Oxygen is delivered safely and more efficiently by the OxyMask than by the Venturi mask in stable oxygen-dependent patients. PMID:16896425
Efficient optical cloud removal technique for earth observation based on MOEMs device
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Lanzoni, Patrick; Liotard, Arnaud; Viard, Thierry; Noell, Wilfried
2017-11-01
In Earth Observation instruments, observation of scenes including bright sources leads to an important degradation of the recorded signal. We propose a new concept to remove dynamically the bright sources and then obtain a field of view with an optically enhanced Signal-to-Noise Ratio (SNR). Micro-Opto-Electro-Mechanical Systems (MOEMS) could be key components in future generation of space instruments. MOEMS-based programmable slit masks will permit the straylight control in future Earth Observation instruments. Experimental demonstration of this concept has been conducted on a dedicated bench. This successful first demonstration shows the high potential of this new concept in future spectro-imager for Earth Observation.
Abnormal spatial frequency channels in esotropic cats.
Holopigian, K; Blake, R
1984-01-01
A noise masking paradigm was used to measure spatial tuning for the deviating and nondeviating eyes of two esotropic cats and for one eye of a control cat. With increasing noise contrast, masking grew more slowly for both the deviating and the nondeviating eyes of the esotropic cats than for the control cat; apparently, contrast coding is impaired for both eyes of the esotropic cats. Masking with band-reject filtered noise indicated that detection channels for either eye of the esotropic cats were twice as broadly tuned as those for the control cat. In a subsequent experiment, the spatial tuning characteristics of two human esotropes were found to be normal, indicating a fundamental difference between human esotropia and esotropia induced in cats by the section of an eye muscle.
Cardoso-Leite, Pedro; Waszak, Florian
2014-07-01
A briefly flashed target stimulus can become "invisible" when immediately followed by a mask-a phenomenon known as backward masking, which constitutes a major tool in the cognitive sciences. One form of backward masking is termed metacontrast masking. It is generally assumed that in metacontrast masking, the mask suppresses activity on which the conscious perception of the target relies. This assumption biases conclusions when masking is used as a tool-for example, to study the independence between perceptual detection and motor reaction. This is because other models can account for reduced perceptual performance without requiring suppression mechanisms. In this study, we used signal detection theory to test the suppression model against an alternative view of metacontrast masking, referred to as the summation model. This model claims that target- and mask-related activations fuse and that the difficulty in detecting the target results from the difficulty to discriminate this fused response from the response produced by the mask alone. Our data support this alternative view. This study is not a thorough investigation of metacontrast masking. Instead, we wanted to point out that when a different model is used to account for the reduced perceptual performance in metacontrast masking, there is no need to postulate a dissociation between perceptual and motor responses to account for the data. Metacontrast masking, as implemented in the Fehrer-Raab situation, therefore is not a valid method to assess perceptual-motor dissociations.
A new suction mask to reduce leak during neonatal resuscitation: a manikin study.
Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G
2016-09-01
Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Jiménez-Ortega, Laura; García-Milla, Marcos; Fondevila, Sabela; Casado, Pilar; Hernández-Gutiérrez, David; Martín-Loeches, Manuel
2014-12-01
Models of language comprehension assume that syntactic processing is automatic, at least at early stages. However, the degree of automaticity of syntactic processing is still controversial. Evidence of automaticity is either indirect or has been observed for pairs of words, which might provide a poor syntactic context in comparison to sentences. The present study investigates the automaticity of syntactic processing using event-related brain potentials (ERPs) during sentence processing. To this end, masked adjectives that could either be syntactically correct or incorrect relative to a sentence being processed appeared just prior to the presentation of supraliminal adjectives. The latter could also be correct or incorrect. According to our data, subliminal gender agreement violations embedded in a sentence trigger an early anterior negativity-like modulation, whereas supraliminal gender agreement violations elicited a later anterior negativity. First-pass syntactic parsing thus appears to be unconsciously and automatically elicited. Interestingly, a P600-like modulation of short duration and early latency could also be observed for masked violations. In addition, masked violations also modulated the P600 component elicited by unmasked targets, probably reflecting that the mechanisms of revising a structural mismatch appear affected by subliminal information. According to our findings, both conscious and unconscious processes apparently contribute to syntactic processing. These results are discussed in line with most recent theories of automaticity and syntactic processing. Copyright © 2014 Elsevier B.V. All rights reserved.
Critical ratios of beluga whales (Delphinapterus leucas) and masked signal duration.
Erbe, Christine
2008-10-01
This article examines the masking of a complex beluga vocalization by natural and anthropogenic noise. The call consisted of six 150 ms pulses exhibiting spectral peaks between 800 Hz and 8 kHz. Comparing the spectra and spectrograms of the call and noises at detection threshold showed that the animal did not hear the entire call at threshold. It only heard parts of the call in frequency and time. From the masked hearing thresholds in broadband continuous noises, critical ratios were computed. Fletcher critical bands were narrower than either 15 or 111 of an octave at the low frequencies of the call (<2 kHz), depending on which frequency the animal cued on. From the masked hearing thresholds in intermittent noises, the audible signal duration at detection threshold was computed. The intermittent noises differed in gap length, gap number, and masking, but the total audible signal duration at threshold was the same: 660 ms. This observation supports a multiple-looks model. The two amplitude modulated noises exhibited weaker masking than the unmodulated noises hinting at a comodulation masking release.
Bang, Abhay T; Bang, Rani A; Baitule, Sanjay B; Reddy, Hanimi M; Deshmukh, Mahesh D
2005-03-01
To evaluate the effect of home-based neonatal care on birth asphyxia and to compare the effectiveness of two types of workers and three methods of resuscitation in home delivery. In a field trial of home-based neonatal care in rural Gadchiroli, India, birth asphyxia in home deliveries was managed differently during different phases. Trained traditional birth attendants (TBA) used mouth-to-mouth resuscitation in the baseline years (1993 to 1995). Additional village health workers (VHWs) only observed in 1995 to 1996. In the intervention years (1996 to 2003), they used tube-mask (1996 to 1999) and bag-mask (1999 to 2003). The incidence, case fatality (CF) and asphyxia-specific mortality rate (ASMR) during different phases were compared. During the intervention years, 5033 home deliveries occurred. VHWs were present during 84% home deliveries. The incidence of mild birth asphyxia decreased by 60%, from 14% in the observation year (1995 to 1996) to 6% in the intervention years (p<0.0001). The incidence of severe asphyxia did not change significantly, but the CF in neonates with severe asphyxia decreased by 47.5%, from 39 to 20% (p<0.07) and ASMR by 65%, from 11 to 4% (p<0.02). Mouth-to-mouth resuscitation reduced the ASMR by 12%, tube-mask further reduced the CF by 27% and the ASMR by 67%. The bag-mask showed an additional decrease in CF of 39% and in the fresh stillbirth rate of 33% in comparison to tube-mask (not significant). The cost of bag and mask was US dollars 13 per averted death. Oxytocic injection administered by unqualified doctors showed an odds ratio of three for the occurrence of severe asphyxia or fresh stillbirth. Home-based interventions delivered by a team of TBA and a semiskilled VHW reduced the asphyxia-related neonatal mortality by 65% compared to only TBA. The bag-mask appears to be superior to tube-mask or mouth-to-mouth resuscitation, with an estimated equipment cost of US dollars 13 per death averted.
Batman flies: a compact spectro-imager for space observation
NASA Astrophysics Data System (ADS)
Zamkotsian, Frederic; Ilbert, Olivier; Zoubian, Julien; Delsanti, Audrey; Boissier, Samuel; Lancon, Ariane
2017-11-01
Multi-object spectroscopy (MOS) is a key technique for large field of view surveys. MOEMS programmable slit masks could be next-generation devices for selecting objects in future infrared astronomical instrumentation for space telescopes. MOS is used extensively to investigate astronomical objects by optimizing the Signal-to-Noise Ratio (SNR): high precision spectra are obtained and the problem of spectral confusion and background level occurring in slitless spectroscopy is cancelled. Fainter limiting fluxes are reached and the scientific return is maximized both in cosmology and in legacy science. Major telescopes around the world are equipped with MOS in order to simultaneously record several hundred spectra in a single observation run. Next generation MOS for space like the Near Infrared Multi-Object Spectrograph (NIRSpec) for the James Webb Space Telescope (JWST) require a programmable multi-slit mask. Conventional masks or complex fiber-optics-based mechanisms are not attractive for space. The programmable multi-slit mask requires remote control of the multislit configuration in real time. During the early-phase studies of the European Space Agency (ESA) EUCLID mission, a MOS instrument based on a MOEMS device has been assessed. Due to complexity and cost reasons, slitless spectroscopy was chosen for EUCLID, despite a much higher efficiency with slit spectroscopy. A promising possible solution is the use of MOEMS devices such as micromirror arrays (MMA) [1,2,3] or micro-shutter arrays (MSA) [4]. MMAs are designed for generating reflecting slits, while MSAs generate transmissive slits. In Europe an effort is currently under way to develop single-crystalline silicon micromirror arrays for future generation infrared multi-object spectroscopy (collaboration LAM / EPFL-CSEM) [5,6]. By placing the programmable slit mask in the focal plane of the telescope, the light from selected objects is directed toward the spectrograph, while the light from other objects and from the sky background is blocked. To get more than 2 millions independent micromirrors, the only available component is a Digital Micromirror Device (DMD) chip from Texas Instruments (TI) that features 2048 x 1080 mirrors and a 13.68μm pixel pitch. DMDs have been tested in space environment (-40°C, vacuum, radiations) by LAM and no showstopper has been revealed [7]. We are presenting in this paper a DMD-based spectrograph called BATMAN, including two arms, one spectroscopic channel and one imaging channel. This instrument is designed for getting breakthrough results in several science cases, from high-z galaxies to nearby galaxies and Trans-Neptunian Objects of Kuiper Belt.
Singh, Narinder Pal; Walker, Robbie James Eades; Cowan, Fiona; Davidson, Arthur Craig; Roberts, David Newton
2014-05-01
Continuous positive airway pressure (CPAP) is the gold standard treatment for moderate to severe obstructive sleep apnoea (OSA). Eye-related side effects of CPAP are commonly attributed to a poorly sealed mask, allowing leaked air to blow over the eye. We present 3 cases where attended polysomnography (A-PSG) demonstrated CPAP-associated retrograde air escape via the nasolacrimal system (CRANS) in the absence of any mask leaks. Symptoms included dry eye, epiphora, air escape from the medial canthus, and eyelid flutter. Symptoms were controlled with a variety of surgical and nonsurgical techniques. CRANS represents a previously undescribed clinical entity. CRANS may be responsible for some CPAP-related eye side effects and possibly for rarer secondary eye complications, including conjunctivitis and corneal ulceration. CRANS should be suspected in any patient on CPAP complaining of eye symptoms. CRANS may be diagnosed through careful observation during A-PSG and confirmed by performing a "saline bubble test." Management options include nonsurgical (mask alternatives, humidification, nasopharyngeal airway) and surgical techniques (nasal airway surgery, inferior turbinate out-fracture and adhesion, injection of bulking agent around Hasner's valve).
Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W
2010-01-01
Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α = .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20) = 48.87, P = .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20) = 16.25, P = .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20) = 43.20, P = .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated.
Reticle haze: an industrial approach
NASA Astrophysics Data System (ADS)
Gough, Stuart; Gérard, Xavier; Bichebois, Pascal; Roche, Agnès; Sundermann, Frank; Guyader, Véronique; Bièron, Yann; Galvier, Jean; Nicoleau, Serge
2007-02-01
Crystal growth on advanced reticles is currently a world wide industrial problem in high end semiconductor production environment, crystals are mainly found on reticles that use high energy photons at 193nm wavelength. The most common crystals to be found on masks are ammonium sulphate, a combination of sulphate, from maskshop residues after clean, pellicle materials and storage conditions and amines from clean room, tool and storage environments. High energy photons act as a catalyst to form crystals on both the pattern side as well as the backglass surface. After a number of exposures crystals can grow in size and eventually become printable. In order to detect HAZE before critical dimensions have been reached suitable detection methods need to be implemented to ensure image integrity. These detection methods are different and complementary depending on the surface to be inspected. Once crystals have started growing, the only method to regain mask quality is to clean the mask at the manufacturers site. This brings with it several undesirable situations, not only is the mask unavailable for production but the cleaning of a mask leads to a potential risk of damaging the mask especially for sub resolution patterns such as scatter bars and phase and transmission changes for eaPSM (Embedded Attenuated Phase Shift Mask) masks. This paper will discuss the initial haze issues seen in a 300mm wafer fab and actions put in place to address the problem. An explanation of results gained from haze reduction actions implemented in a wafer fab will be given. Haze seen by reticle inspection and surface analysis tools can be characterised by typical contamination patterns. These signatures appear after a certain number of wafers exposed depending on several reticle variables such as transmission, Binary, eaPSM, Pellicle. Details will be given of how reticles are managed to ensure minimum impact to a production environment with an appropriate reticle control plan. AMC (Airborne Molecular Contamination) in wafer fab and equipment environment is a key factor for crystal growth. The type of filtration installed to reduce AMC and method of atmospheric monitoring for critical areas will be explained. Choice of reticle storage conditions and materials used for transport during the life of the reticle will be included. Improvements in maskshop cleaning processes, reticle materials and environmental control have lead to extended mask lifetime in the wafer fab of more than 20 times. The fundamental differences and relative monitoring will be described and gain from implemented actions will be presented Once crystals have started growing, the only method to regain mask quality is to clean the mask at the manufacturers site. This brings with it several undesirable situations, not only is the mask unavailable for production but the cleaning of a mask leads to a potential risk of damaging the mask especially for sub resolution patterns such as scatter bars and phase and transmission changes for eaPSM (Embedded Attenuated Phase Shift Mask) masks. This paper will discuss the initial haze issues seen in a 300mm wafer fab and actions put in place to address the problem. An explanation of results gained from haze reduction actions implemented in a wafer fab will be given. Haze seen by reticle inspection and surface analysis tools can be characterised by typical contamination patterns. These signatures appear after a certain number of wafers exposed depending on several reticle variables such as transmission, Binary, eaPSM, Pellicle. Details will be given of how reticles are managed to ensure minimum impact to a production environment with an appropriate reticle control plan. AMC (Airborne Molecular Contamination) in wafer fab and equipment environment is a key factor for crystal growth. The type of filtration installed to reduce AMC and method of atmospheric monitoring for critical areas will be explained. Choice of reticle storage conditions and materials used for transport during the life of the reticle will be included. Improvements in maskshop cleaning processes, reticle materials and environmental control have lead to extended mask lifetime in the wafer fab of more than 20 times. The fundamental differences and relative monitoring will be described and gain from implemented actions will be presented
A conceptual approach to the masking effect of measures of disproportionality.
Maignen, Francois; Hauben, Manfred; Hung, Eric; Holle, Lionel Van; Dogne, Jean-Michel
2014-02-01
Masking is a statistical issue by which true signals of disproportionate reporting are hidden by the presence of other products in the database. Masking is currently not perfectly understood. There is no algorithm to identify the potential masking drugs to remove them for subsequent analyses of disproportionality. The primary objective of our study is to develop a mathematical framework for assessing the extent and impact of the masking effect of measures of disproportionality. We have developed a masking ratio that quantifies the masking effect of a given product. We have conducted a simulation study to validate our algorithm. The masking ratio is a measure of the strength of the masking effect whether the analysis is performed at the report or event level, and the manner in which reports are allocated to cells in the contingency table significantly impact the masking mechanisms. The reports containing both the product of interest and the masking product need to be handled appropriately. The proposed algorithm can use simplified masking provided that underlying assumptions (in particular the size of the database) are verified. For any event, the strongest masking effect is associated with the drug with the highest number of records (reports excluding the product of interest). Our study provides significant insights with practical implications for real-world pharmacovigilance that are supported by both real and simulated data. The public health impact of masking is still unknown. Copyright © 2013 John Wiley & Sons, Ltd.
XBAER-derived aerosol optical thickness from OLCI/Sentinel-3 observation
NASA Astrophysics Data System (ADS)
Mei, Linlu; Rozanov, Vladimir; Vountas, Marco; Burrows, John P.; Richter, Andreas
2018-02-01
A cloud identification algorithm used for cloud masking, which is based on the spatial variability of reflectances at the top of the atmosphere in visible wavelengths, has been developed for the retrieval of aerosol properties by MODIS. It is shown that the spatial pattern of cloud reflectance, as observed from space, is very different from that of aerosols. Clouds show a high spatial variability in the scale of a hundred metres to a few kilometres, whereas aerosols in general are homogeneous. The concept of spatial variability of reflectances at the top of the atmosphere is mainly applicable over the ocean, where the surface background is sufficiently homogeneous for the separation between aerosols and clouds. Aerosol retrievals require a sufficiently accurate cloud identification to be able to mask these ground scenes. However, a conservative mask will exclude strong aerosol episodes and a less conservative mask could introduce cloud contamination that biases the retrieved aerosol optical properties (e.g. aerosol optical depth and effective radii). A detailed study on the effect of cloud contamination on aerosol retrievals has been performed and parameters are established determining the threshold value for the MODIS aerosol cloud mask (3×3-STD) over the ocean. The 3×3-STD algorithm discussed in this paper is the operational cloud mask used for MODIS aerosol retrievals over the ocean.A prolonged pollution haze event occurred in the northeast part of China during the period 16-21 December 2016. To assess the impact of such events, the amounts and distribution of aerosol particles, formed in such events, need to be quantified. The newly launched Ocean Land Colour Instrument (OLCI) onboard Sentinel-3 is the successor of the MEdium Resolution Imaging Spectrometer (MERIS). It provides measurements of the radiance and reflectance at the top of the atmosphere, which can be used to retrieve the aerosol optical thickness (AOT) from synoptic to global scales. In this study, the recently developed AOT retrieval algorithm eXtensible Bremen AErosol Retrieval (XBAER) has been applied to data from the OLCI instrument for the first time to illustrate the feasibility of applying XBAER to the data from this new instrument. The first global retrieval results show similar patterns of aerosol optical thickness, AOT, to those from MODIS and MISR aerosol products. The AOT retrieved from OLCI is validated by comparison with AERONET observations and a correlation coefficient of 0.819 and bias (root mean square) of 0.115 is obtained. The haze episode is well captured by the OLCI-derived AOT product. XBAER is shown to retrieve AOT well from the observations of MERIS and OLCI.
Wood, Michelle E; Stockwell, Rebecca E; Johnson, Graham R; Ramsay, Kay A; Sherrard, Laura J; Jabbour, Nassib; Ballard, Emma; O'Rourke, Peter; Kidd, Timothy J; Wainwright, Claire E; Knibbs, Luke D; Sly, Peter D; Morawska, Lidia; Bell, Scott C
2018-02-01
People with cystic fibrosis (CF) generate Pseudomonas aeruginosa in droplet nuclei during coughing. The use of surgical masks has been recommended in healthcare settings to minimize pathogen transmission between patients with CF. To determine if face masks and cough etiquette reduce viable P. aeruginosa aerosolized during coughing. Twenty-five adults with CF and chronic P. aeruginosa infection were recruited. Participants performed six talking and coughing maneuvers, with or without face masks (surgical and N95) and hand covering the mouth when coughing (cough etiquette) in an aerosol-sampling device. An Andersen Cascade Impactor was used to sample the aerosol at 2 meters from each participant. Quantitative sputum and aerosol bacterial cultures were performed, and participants rated the mask comfort levels during the cough maneuvers. During uncovered coughing (reference maneuver), 19 of 25 (76%) participants produced aerosols containing P. aeruginosa, with a positive correlation found between sputum P. aeruginosa concentration (measured as cfu/ml) and aerosol P. aeruginosa colony-forming units. There was a reduction in aerosol P. aeruginosa load during coughing with a surgical mask, coughing with an N95 mask, and cough etiquette compared with uncovered coughing (P < 0.001). A similar reduction in total colony-forming units was observed for both masks during coughing; yet, participants rated the surgical masks as more comfortable (P = 0.013). Cough etiquette provided approximately half the reduction of viable aerosols of the mask interventions during voluntary coughing. Talking was a low viable aerosol-producing activity. Face masks reduce cough-generated P. aeruginosa aerosols, with the surgical mask providing enhanced comfort. Cough etiquette was less effective at reducing viable aerosols.
Silverstein, David N.
2015-01-01
In human perception studies, visual backward masking has been used to understand the temporal dynamics of subliminal vs. conscious perception. When a brief target stimulus is followed by a masking stimulus after a short interval of <100 ms, performance on the target is impaired when the target and mask are in close spatial proximity. While the psychophysical properties of backward masking have been studied extensively, there is still debate on the underlying cortical dynamics. One prevailing theory suggests that the impairment of target performance due to the mask is the result of lateral inhibition between the target and mask in feedforward processing. Another prevailing theory suggests that this impairment is due to the interruption of feedback processing of the target by the mask. This computational study demonstrates that both aspects of these theories may be correct. Using a biophysical model of V1 and V2, visual processing was modeled as interacting neocortical attractors, which must propagate up the visual stream. If an activating target attractor in V1 is quiesced enough with lateral inhibition from a mask, or not reinforced by recurrent feedback, it is more likely to burn out before becoming fully active and progressing through V2 and beyond. Results are presented which simulate metacontrast backward masking with an increasing stimulus interval and with the presence and absence of feedback activity. This showed that recurrent feedback diminishes backward masking effects and can make conscious perception more likely. One model configuration presented a metacontrast noise mask in the same hypercolumns as the target, and produced type-A masking. A second model configuration presented a target line with two parallel adjacent masking lines, and produced type-B masking. Future work should examine how the model extends to more complex spatial mask configurations. PMID:25759672
Controls Astrophysics and Structures Experiment in Space (CASES) advanced studies and planning
NASA Technical Reports Server (NTRS)
Wu, S. T.
1989-01-01
The CASES (Controls, Astrophysics, and Structures Experiment in Space) program consists of a flight demonstration of CSI (Controls-Structures Interactions) technology on the Space Shuttle. The basis structure consists of a 32 m deployable boom with actuators and sensors distributed along its length. Upon deployment from the Orbiter bay, the CASES structure will be characterized dynamically and its deformations controlled by a series of experimental control laws; and cold gas thrusters at its tip will be used to orient the Orbiter to a fixed celestial reference. The scientific observations will consist of hard x-ray imaging, at high resolution, of the Sun and the Galactic center. The hard x-ray observations require stable (few arc min) pointing at these targets for one or more position-sensitive proportional counters in the Orbiter bay, which view the object to be imaged through an aperture-encoding mask at the boom tip. This report gives the concensus developed at the second CASES Science Working Group meeting, which took place at NASA Marshall Space Flight Center May 16-17, 1990. An earlier paper and scientific summaries are available and form the basis for the present discussion.
Verhey, Jesko L; Epp, Bastian; Stasiak, Arkadiusz; Winter, Ian M
2013-01-01
A common characteristic of natural sounds is that the level fluctuations in different frequency regions are coherent. The ability of the auditory system to use this comodulation is shown when a sinusoidal signal is masked by a masker centred at the signal frequency (on-frequency masker, OFM) and one or more off-frequency components, commonly referred to as flanking bands (FBs). In general, the threshold of the signal masked by comodulated masker components is lower than when masked by masker components with uncorrelated envelopes or in the presence of the OFM only. This effect is commonly referred to as comodulation masking release (CMR). The present study investigates if CMR is also observed for a sinusoidal signal embedded in the OFM when the centre frequencies of the FBs are swept over time with a sweep rate of one octave per second. Both a common change of different frequencies and comodulation could serve as cues to indicate which of the stimulus components originate from one source. If the common fate of frequency components is the stronger binding cue, the sweeping FBs and the OFM with a fixed centre frequency should no longer form one auditory object and the CMR should be abolished. However, psychoacoustical results with normal-hearing listeners show that a CMR is also observed with sweeping components. The results are consistent with the hypothesis of wideband inhibition as the underlying physiological mechanism, as the CMR should only depend on the spectral position of the flanking bands relative to the inhibitory areas (as seen in physiological recordings using stationary flanking bands). Preliminary physiological results in the cochlear nucleus of the Guinea pig show that a correlate of CMR can also be found at this level of the auditory pathway with sweeping flanking bands.
X ray reflection masks: Manufacturing, characterization and first tests
NASA Astrophysics Data System (ADS)
Rahn, Stephen
1992-09-01
SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.
Analysis and modeling of photomask edge effects for 3D geometries and the effect on process window
NASA Astrophysics Data System (ADS)
Miller, Marshal A.; Neureuther, Andrew R.
2009-03-01
Simulation was used to explore boundary layer models for 1D and 2D patterns that would be appropriate for fast CAD modeling of physical effects during design. FDTD simulation was used to compare rigorous thick mask modeling to a thin mask approximation (TMA). When features are large, edges can be viewed as independent and modeled as separate from one another, but for small mask features, edges experience cross-talk. For attenuating phase-shift masks, interaction distances as large as 150nm were observed. Polarization effects are important for accurate EMF models. Due to polarization effects, the edge perturbations in line ends become different compared to a perpendicular edge. For a mask designed to be real, the 90o transmission created at edges produces an asymmetry through focus, which is also polarization dependent. Thick mask fields are calculated using TEMPEST and Panoramic Technologies software. Fields are then analyzed in the near field and on wafer CDs to examine deviations from TMA.
Clean induced feature CD shift of EUV mask
NASA Astrophysics Data System (ADS)
Nesládek, Pavel; Schedel, Thorsten; Bender, Markus
2016-05-01
EUV developed in the last decade to the most promising <7nm technology candidate. Defects are considered to be one of the most critical issues of the EUV mask. There are several contributors which make the EUV mask so different from the optical one. First one is the significantly more complicated mask stack consisting currently of 40 Mo/Si double layers, covered by Ru capping layer and TaN/TaO absorber/anti-reflective coating on top of the front face of the mask. Backside is in contrary to optical mask covered as well by conductive layer consisting of Cr or CrN. Second contributor is the fact that EUV mask is currently in contrary to optical mask not yet equipped with sealed pellicle, leading to much higher risk of mask contamination. Third reason is use of EUV mask in vacuum, possibly leading to deposition of vacuum contaminants on the EUV mask surface. Latter reason in combination with tight requirements on backside cleanliness lead to the request of frequent recleaning of the EUV mask, in order to sustain mask lifetime similar to that of optical mask. Mask cleaning process alters slightly the surface of any mask - binary COG mask, as well as phase shift mask of any type and naturally also of the EUV mask as well. In case of optical masks the changes are almost negligible, as the mask is exposed to max. 10-20 re-cleans within its life time. These modifications can be expressed in terms of different specified parameters, e.g. CD shift, phase/trans shift, change of the surface roughness etc. The CD shift, expressed as thinning (or exceptionally thickening) of the dark features on the mask is typically in order of magnitude 0.1nm per process run, which is completely acceptable for optical mask. Projected on the lifetime of EUV mask, assuming 100 clean process cycles, this will lead to CD change of about 10nm. For this reason the requirements for EUV mask cleaning are significantly tighter, << 0.1 nm per process run. This task will look even more challenging, when considering, that the tools for CD measurement at the EUV mask are identical as for optical mask. There is one aspect influencing the CD shift, which demands attention. The mask composition of the EUV mask is significantly different from the optical mask. More precisely there are 2 materials influencing the estimated CD in case of EUV mask, whereas there is one material only in case of optical masks, in first approximation. For optical masks, the CD changes can be attributed to modification of the absorber/ARC layer, as the quartz substrate can be hardly modified by the wet process. For EUV Masks chemical modification of the Ru capping layer - thinning, oxidization etc. are rather more probable and we need to take into account, how this effects can influence the CD measurement process. CD changes measured can be interpreted as either change in the feature size, or modification of the chemical nature of both absorber/ARC layer stack and the Ru capping layer. In our work we try to separate the effect of absorber and Ru/capping layer on the CD shift observed and propose independent way of estimation both parameters.
New mask technology challenges
NASA Astrophysics Data System (ADS)
Kimmel, Kurt R.
2001-09-01
Mask technology development has accelerated dramatically in recent years from the glacial pace of the last three decades to the rapid and sometimes simultaneous introductions of new wavelengths and mask-based resolution enhancement techniques. The nature of the semiconductor business has also become one driven by time-to-market as an overwhelming factor in capturing market share and profit. These are among the factors that have created enormous stress on the mask industry to produce masks with enhanced capabilities, such as phase-shifting attenuators, sub-resolution assist bars, and optical proximity correction (OPC) features, while maintaining or reducing cost and cycle time. The mask can no longer be considered a commodity item that is purchased form the lowest-cost supplier. Instead, it must now be promoted as an integral part of the technical and business case for a total lithographic solution. Improving partnership between designer, mask-maker, and wafer lithographer will be the harbinger of success in finding a profitable balance of capability, cost, and cycle time. Likewise for equipment infrastructure development, stronger partnership on the international level is necessary to control development cost and mitigate schedule and technical risks.
Young, Kymberly D; Misaki, Masaya; Harmer, Catherine J; Victor, Teresa; Zotev, Vadim; Phillips, Raquel; Siegle, Greg J; Drevets, Wayne C; Bodurka, Jerzy
2017-10-15
In participants with major depressive disorder who are trained to upregulate their amygdalar hemodynamic responses during positive autobiographical memory recall with real-time functional magnetic resonance imaging neurofeedback (rtfMRI-nf) training, depressive symptoms diminish. This study tested whether amygdalar rtfMRI-nf also changes emotional processing of positive and negative stimuli in a variety of behavioral and imaging tasks. Patients with major depressive disorder completed two rtfMRI-nf sessions (18 received amygdalar rtfMRI-nf, 16 received control parietal rtfMRI-nf). One week before and following rtfMRI-nf training, participants performed tasks measuring responses to emotionally valenced stimuli including a backward-masking task, which measures the amygdalar hemodynamic response to emotional faces presented for traditionally subliminal duration and followed by a mask, and the Emotional Test Battery in which reaction times and performance accuracy are measured during tasks involving emotional faces and words. During the backward-masking task, amygdalar responses increased while viewing masked happy faces but decreased to masked sad faces in the experimental versus control group following rtfMRI-nf. During the Emotional Test Battery, reaction times decreased to identification of positive faces and during self-identification with positive words and vigilance scores increased to positive faces and decreased to negative faces during the faces dot-probe task in the experimental versus control group following rtfMRI-nf. rtfMRI-nf training to increase the amygdalar hemodynamic response to positive memories was associated with changes in amygdalar responses to happy and sad faces and improved processing of positive stimuli during performance of the Emotional Test Battery. These results may suggest that amygdalar rtfMRI-nf training alters responses to emotional stimuli in a manner similar to antidepressant pharmacotherapy. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Manufacturability study of masks created by inverse lithography technology (ILT)
NASA Astrophysics Data System (ADS)
Martin, Patrick M.; Progler, C. J.; Xiao, G.; Gray, R.; Pang, L.; Liu, Y.
2005-11-01
As photolithography is pushed to fabricate deep-sub wavelength devices for 90nm, 65nm and smaller technology nodes using available exposure tools (i.e., 248nm, 193nm steppers), photomask capability is becoming extremely critical. For example, PSM masks require more complicated processing; aggressive OPC makes the writing time longer and sometimes unpredictable; and, high MEEF imposes much more stringent demands on mask quality. Therefore, in order for any new lithography technology to be adopted into production, mask manufacturability must be studied thoroughly and carefully. In this paper we will present the mask manufacturability study on mask patterns created using Inverse Lithography Technology (ILT). Unlike conventional OPC methodologies, ILT uses a unique outcome-based technology to mathematically determine the mask features that produce the desired on-wafer results. ILT solves the most critical litho challenges of the deep sub-wavelength era. Potential benefits include: higher yield; expanded litho process windows; superb pattern fidelity at 90, 65 & 45-nm nodes; and reduced time-to-silicon - all without changing the existing lithography infrastructure and design-to-silicon flow. In this study a number of cell structures were selected and used as test patterns. "Luminized patterns" were generated for binary mask and attenuated phase-shift mask. Both conventional OPC patterns and "luminized patterns" were put on a test reticle side by side, and they all have a number of variations in term of correction aggressivity level and mask complexity. Mask manufacturability, including data fracturing, writing time, mask inspection, and metrology were studied. The results demonstrate that, by optimizing the inspection recipe, masks created using ILT technology can be made and qualified using current processes with a reasonable turn-around time.
Testing the efficacy of homemade masks: would they protect in an influenza pandemic?
Davies, Anna; Thompson, Katy-Anne; Giri, Karthika; Kafatos, George; Walker, Jimmy; Bennett, Allan
2013-08-01
This study examined homemade masks as an alternative to commercial face masks. Several household materials were evaluated for the capacity to block bacterial and viral aerosols. Twenty-one healthy volunteers made their own face masks from cotton t-shirts; the masks were then tested for fit. The number of microorganisms isolated from coughs of healthy volunteers wearing their homemade mask, a surgical mask, or no mask was compared using several air-sampling techniques. The median-fit factor of the homemade masks was one-half that of the surgical masks. Both masks significantly reduced the number of microorganisms expelled by volunteers, although the surgical mask was 3 times more effective in blocking transmission than the homemade mask. Our findings suggest that a homemade mask should only be considered as a last resort to prevent droplet transmission from infected individuals, but it would be better than no protection.
VizieR Online Data Catalog: GMOS spectroscopic obs. of SNR candidates in M83 (Winkler+, 2017)
NASA Astrophysics Data System (ADS)
Winkler, P. F.; Blair, W. P.; Long, K. S.
2017-11-01
We used the GMOS on the 8.2m Gemini-South telescope to obtain all the spectra reported here. Most were obtained in a classically scheduled observing run on 2011 April 7-9 (UT); masks 1-7. We later obtained spectra for two additional masks (which we refer to as masks 8 and 9 for simplicity) in a queue-scheduled program (GS-2015A-Q-90) during the 2015A semester. (6 data files).
Lee, Junghee; Cohen, Mark S; Engel, Stephen A; Glahn, David; Nuechterlein, Keith H; Wynn, Jonathan K; Green, Michael F
2010-07-01
Visual masking paradigms assess the early part of visual information processing, which may reflect vulnerability measures for schizophrenia. We examined the neural substrates of visual backward performance in unaffected sibling of schizophrenia patients using functional magnetic resonance imaging (fMRI). Twenty-one unaffected siblings of schizophrenia patients and 19 healthy controls performed a backward masking task and three functional localizer tasks to identify three visual processing regions of interest (ROI): lateral occipital complex (LO), the motion-sensitive area, and retinotopic areas. In the masking task, we systematically manipulated stimulus onset asynchronies (SOAs). We analyzed fMRI data in two complementary ways: 1) an ROI approach for three visual areas, and 2) a whole-brain analysis. The groups did not differ in behavioral performance. For ROI analysis, both groups increased activation as SOAs increased in LO. Groups did not differ in activation levels of the three ROIs. For whole-brain analysis, controls increased activation as a function of SOAs, compared with siblings in several regions (i.e., anterior cingulate cortex, posterior cingulate cortex, inferior prefrontal cortex, inferior parietal lobule). The study found: 1) area LO showed sensitivity to the masking effect in both groups; 2) siblings did not differ from controls in activation of LO; and 3) groups differed significantly in several brain regions outside visual processing areas that have been related to attentional or re-entrant processes. These findings suggest that LO dysfunction may be a disease indicator rather than a risk indicator for schizophrenia. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Zhang, Lijie; Peng, Zhibin; Ou, Jianming; Zeng, Guang; Fontaine, Robert E; Liu, Mingbin; Cui, Fuqiang; Hong, Rongtao; Zhou, Hang; Huai, Yang; Chuang, Shuk-Kwan; Leung, Yiu-Hong; Feng, Yunxia; Luo, Yuan; Shen, Tao; Zhu, Bao-Ping; Widdowson, Marc-Alain; Yu, Hongjie
2013-01-01
In response to several influenza A(H1N1)pdm09 infections that developed in passengers after they traveled on the same 2 flights from New York, New York, USA, to Hong Kong, China, to Fuzhou, China, we assessed transmission of influenza A(H1N1)pdm09 virus on these flights. We defined a case of infection as onset of fever and respiratory symptoms and detection of virus by PCR in a passenger or crew member of either flight. Illness developed only in passengers who traveled on the New York to Hong Kong flight. We compared exposures of 9 case-passengers with those of 32 asymptomatic control-passengers. None of the 9 case-passengers, compared with 47% (15/32) of control-passengers, wore a face mask for the entire flight (odds ratio 0, 95% CI 0-0.71). The source case-passenger was not identified. Wearing a face mask was a protective factor against influenza infection. We recommend a more comprehensive intervention study to accurately estimate this effect.
Tachistoscopic illumination and masking of real scenes
Chichka, David; Philbeck, John W.; Gajewski, Daniel A.
2014-01-01
Tachistoscopic presentation of scenes has been valuable for studying the emerging properties of visual scene representations. The spatial aspects of this work have generally been focused on the conceptual locations (e.g., next to the refrigerator) and the directional locations of objects in 2D arrays and/or images. Less is known about how the perceived egocentric distance of objects develops. Here we describe a novel system for presenting brief glimpses of a real-world environment, followed by a mask. The system includes projectors with mechanical shutters for projecting the fixation and masking images, a set of LED floodlights for illuminating the environment, and computer-controlled electronics to set the timing and initiate the process. Because a real environment is used, most visual distance and depth cues may be manipulated using traditional methods. The system is inexpensive, robust, and its components are readily available in the marketplace. This paper describes the system and the timing characteristics of each component. Verification of the ability to control exposure to time scales as low as a few milliseconds is demonstrated. PMID:24519496
Zhang, Lijie; Peng, Zhibin; Ou, Jianming; Zeng, Guang; Fontaine, Robert E.; Liu, Mingbin; Cui, Fuqiang; Hong, Rongtao; Zhou, Hang; Huai, Yang; Chuang, Shuk-Kwan; Leung, Yiu-Hong; Feng, Yunxia; Luo, Yuan; Shen, Tao; Zhu, Bao-Ping; Widdowson, Marc-Alain
2013-01-01
In response to several influenza A(H1N1)pdm09 infections that developed in passengers after they traveled on the same 2 flights from New York, New York, USA, to Hong Kong, China, to Fuzhou, China, we assessed transmission of influenza A(H1N1)pdm09 virus on these flights. We defined a case of infection as onset of fever and respiratory symptoms and detection of virus by PCR in a passenger or crew member of either flight. Illness developed only in passengers who traveled on the New York to Hong Kong flight. We compared exposures of 9 case-passengers with those of 32 asymptomatic control-passengers. None of the 9 case-passengers, compared with 47% (15/32) of control-passengers, wore a face mask for the entire flight (odds ratio 0, 95% CI 0–0.71). The source case-passenger was not identified. Wearing a face mask was a protective factor against influenza infection. We recommend a more comprehensive intervention study to accurately estimate this effect. PMID:23968983
NASA Astrophysics Data System (ADS)
Trepte, Q. Z.; Minnis, P.; Palikonda, R.; Bedka, K. M.; Sun-Mack, S.
2011-12-01
Accurate detection of cloud amount and distribution using satellite observations is crucial in determining cloud radiative forcing and earth energy budget. The CERES-MODIS (CM) Edition 4 cloud mask is a global cloud detection algorithm for application to Terra and Aqua MODIS data with the aid of other ancillary data sets. It is used operationally for the NASA's Cloud and Earth's Radiant Energy System (CERES) project. The LaRC AVHRR cloud mask, which uses only five spectral channels, is based on a subset of the CM cloud mask which employs twelve MODIS channels. The LaRC mask is applied to AVHRR data for the NOAA Climate Data Record Program. Comparisons among the CM Ed4, and LaRC AVHRR cloud masks and the CALIPSO Vertical Feature Mask (VFM) constitute a powerful means for validating and improving cloud detection globally. They also help us understand the strengths and limitations of the various cloud retrievals which use either active and passive satellite sensors. In this paper, individual comparisons will be presented for different types of clouds over various surfaces, including daytime and nighttime, and polar and non-polar regions. Additionally, the statistics of the global, regional, and zonal cloud occurrence and amount from the CERES Ed4, AVHRR cloud masks and CALIPSO VFM will be discussed.
Molindone and haloperidol in tardive dyskinesia.
Glazer, W M; Hafez, H M; Benarroche, C L
1985-08-01
Preliminary results are described from a study of 11 outpatients manifesting exacerbated tardive dyskinesia after tapering and withdrawal of neuroleptic medications. Patients were randomly assigned to molindone or haloperidol under double-blind placebo-controlled conditions to compare the masking effects of the two drugs. Haloperidol treatment masked withdrawal-exacerbated tardive dyskinesia more than molindone did; this difference (measured by percent change in AIMS scores) was significant (p = .04) when the dose was 200% but not 100% of the prestudy neuroleptic dose. Despite several limitations to the study, the results suggest that molindone may have less dyskinetogenic potential than haloperidol. Further research in the area of site-specificity of molindone is indicated.
2013-01-01
Background Currently there is an ongoing debate and limited evidence on the use of masks and respirators for the prevention of respiratory infections in health care workers (HCWs). This study aimed to examine available policies and guidelines around the use of masks and respirators in HCWs and to describe areas of consistency between guidelines, as well as gaps in the recommendations, with reference to the WHO and the CDC guidelines. Methods Policies and guidelines related to mask and respirator use for the prevention of influenza, SARS and TB were examined. Guidelines from the World Health Organization (WHO), the Center for Disease Control and Prevention (CDC), three high-income countries and six low/middle-income countries were selected. Results Uniform recommendations are made by the WHO and the CDC in regards to protecting HCWs against seasonal influenza (a mask for low risk situations and a respirator for high risk situations) and TB (use of a respirator). However, for pandemic influenza and SARS, the WHO recommends mask use in low risk and respirators in high risk situations, whereas, the CDC recommends respirators in both low and high risk situations. Amongst the nine countries reviewed, there are variations in the recommendations for all three diseases. While, some countries align with the WHO recommendations, others align with those made by the CDC. The choice of respirator and the level of filtering ability vary amongst the guidelines and the different diseases. Lastly, none of the policies discuss reuse, extended use or the use of cloth masks. Conclusion Currently, there are significant variations in the policies and recommendations around mask and respirator use for protection against influenza, SARS and TB. These differences may reflect the scarcity of level-one evidence available to inform policy development. The lack of any guidelines on the use of cloth masks, despite widespread use in many low and middle-income countries, remains a policy gap. Health organizations and countries should jointly evaluate the available evidence, prioritize research to inform evidence gaps, and develop consistent policy on masks and respirator use in the health care setting. PMID:23725338
Chughtai, Abrar Ahmad; Seale, Holly; MacIntyre, Chandini Raina
2013-05-31
Currently there is an ongoing debate and limited evidence on the use of masks and respirators for the prevention of respiratory infections in health care workers (HCWs). This study aimed to examine available policies and guidelines around the use of masks and respirators in HCWs and to describe areas of consistency between guidelines, as well as gaps in the recommendations, with reference to the WHO and the CDC guidelines. Policies and guidelines related to mask and respirator use for the prevention of influenza, SARS and TB were examined. Guidelines from the World Health Organization (WHO), the Center for Disease Control and Prevention (CDC), three high-income countries and six low/middle-income countries were selected. Uniform recommendations are made by the WHO and the CDC in regards to protecting HCWs against seasonal influenza (a mask for low risk situations and a respirator for high risk situations) and TB (use of a respirator). However, for pandemic influenza and SARS, the WHO recommends mask use in low risk and respirators in high risk situations, whereas, the CDC recommends respirators in both low and high risk situations. Amongst the nine countries reviewed, there are variations in the recommendations for all three diseases. While, some countries align with the WHO recommendations, others align with those made by the CDC. The choice of respirator and the level of filtering ability vary amongst the guidelines and the different diseases. Lastly, none of the policies discuss reuse, extended use or the use of cloth masks. Currently, there are significant variations in the policies and recommendations around mask and respirator use for protection against influenza, SARS and TB. These differences may reflect the scarcity of level-one evidence available to inform policy development. The lack of any guidelines on the use of cloth masks, despite widespread use in many low and middle-income countries, remains a policy gap. Health organizations and countries should jointly evaluate the available evidence, prioritize research to inform evidence gaps, and develop consistent policy on masks and respirator use in the health care setting.
Etch bias inversion during EUV mask ARC etch
NASA Astrophysics Data System (ADS)
Lajn, Alexander; Rolff, Haiko; Wistrom, Richard
2017-07-01
The introduction of EUV lithography to high volume manufacturing is now within reach for 7nm technology node and beyond (1), at least for some steps. The scheduling is in transition from long to mid-term. Thus, all contributors need to focus their efforts on the production requirements. For the photo mask industry, these requirements include the control of defectivity, CD performance and lifetime of their masks. The mask CD performance including CD uniformity, CD targeting, and CD linearity/ resolution, is predominantly determined by the photo resist performance and by the litho and etch processes. State-of-the-art chemically amplified resists exhibit an asymmetric resolution for directly and indirectly written features, which usually results in a similarly asymmetric resolution performance on the mask. This resolution gap may reach as high as multiple tens of nanometers on the mask level in dependence of the chosen processes. Depending on the printing requirements of the wafer process, a reduction or even an increase of this gap may be required. A potential way of tuning via the etch process, is to control the lateral CD contribution during etch. Aside from process tuning knobs like pressure, RF powers and gases, which usually also affect CD linearity and CD uniformity, the simplest knob is the etch time itself. An increased over etch time results in an increased CD contribution in the normal case. , We found that the etch CD contribution of ARC layer etch on EUV photo masks is reduced by longer over etch times. Moreover, this effect can be demonstrated to be present for different etch chambers and photo resists.
NASA Astrophysics Data System (ADS)
Mamezaki, Daiki; Harada, Tetsuo; Nagata, Yutaka; Watanabe, Takeo
2017-06-01
In extreme-ultraviolet (EUV) lithography, the development of a review apparatus for the EUV mask pattern at an exposure wavelength of 13.5 nm is required. The EUV mask is composed of an absorber pattern and a Mo/Si multilayer on a glass substrate. This mask pattern has a three-dimensional (3D) structure. The 3D structure would modulate the EUV reflection phase, which would cause focus and pattern shifts. Thus, the review of the EUV phase image is also important. We have developed a coherent EUV scatterometry microscope (CSM), which is a simple microscope without objective optics. The EUV phase and intensity images were reconstructed with diffraction images by ptychography. For a standalone mask review, the high-harmonic-generation (HHG) EUV source was employed. In this study, we updated the sample stage, pump-laser reduction system, and gas-pressure control system to reconstruct the image. As a result, an 88 nm line-and-space pattern and a cross-line pattern were reconstructed. In addition, a particle defect of 2 µm diameter was well reconstructed. This demonstrated the high capability of the standalone CSM, which can hence be used in factories, such as mask shops and semiconductor fabrication plants.
Temporal masking functions for listeners with real and simulated hearing loss
Desloge, Joseph G.; Reed, Charlotte M.; Braida, Louis D.; Perez, Zachary D.; Delhorne, Lorraine A.
2011-01-01
A functional simulation of hearing loss was evaluated in its ability to reproduce the temporal masking functions for eight listeners with mild to severe sensorineural hearing loss. Each audiometric loss was simulated in a group of age-matched normal-hearing listeners through a combination of spectrally-shaped masking noise and multi-band expansion. Temporal-masking functions were obtained in both groups of listeners using a forward-masking paradigm in which the level of a 110-ms masker required to just mask a 10-ms fixed-level probe (5-10 dB SL) was measured as a function of the time delay between the masker offset and probe onset. At each of four probe frequencies (500, 1000, 2000, and 4000 Hz), temporal-masking functions were obtained using maskers that were 0.55, 1.0, and 1.15 times the probe frequency. The slopes and y-intercepts of the masking functions were not significantly different for listeners with real and simulated hearing loss. The y-intercepts were positively correlated with level of hearing loss while the slopes were negatively correlated. The ratio of the slopes obtained with the low-frequency maskers relative to the on-frequency maskers was similar for both groups of listeners and indicated a smaller compressive effect than that observed in normal-hearing listeners. PMID:21877806
The impact of perilaryngeal vibration on the self-perception of loudness and the Lombard effect.
Brajot, François-Xavier; Nguyen, Don; DiGiovanni, Jeffrey; Gracco, Vincent L
2018-04-05
The role of somatosensory feedback in speech and the perception of loudness was assessed in adults without speech or hearing disorders. Participants completed two tasks: loudness magnitude estimation of a short vowel and oral reading of a standard passage. Both tasks were carried out in each of three conditions: no-masking, auditory masking alone, and mixed auditory masking plus vibration of the perilaryngeal area. A Lombard effect was elicited in both masking conditions: speakers unconsciously increased vocal intensity. Perilaryngeal vibration further increased vocal intensity above what was observed for auditory masking alone. Both masking conditions affected fundamental frequency and the first formant frequency as well, but only vibration was associated with a significant change in the second formant frequency. An additional analysis of pure-tone thresholds found no difference in auditory thresholds between masking conditions. Taken together, these findings indicate that perilaryngeal vibration effectively masked somatosensory feedback, resulting in an enhanced Lombard effect (increased vocal intensity) that did not alter speakers' self-perception of loudness. This implies that the Lombard effect results from a general sensorimotor process, rather than from a specific audio-vocal mechanism, and that the conscious self-monitoring of speech intensity is not directly based on either auditory or somatosensory feedback.
Bitter taste masking of enzyme-treated soy protein in water and bread.
Bertelsen, Anne S; Laursen, Anne; Knudsen, Tine A; Møller, Stine; Kidmose, Ulla
2018-08-01
Bioactive protein hydrolysates are often very bitter. To overcome this challenge, xylitol, sucrose, α-cyclodextrin, maltodextrin and combinations of these were tested systematically as bitter-masking agents of an enzyme-treated soy protein in an aqueous model and in a bread model. Sensory descriptive analysis was used to reveal the bitter-masking effect of the taste-masking blends on the enzyme-treated soy protein. In water, xylitol, sucrose and maltodextrin reduced bitterness significantly, whereas α-cyclodextrin did not. No significant difference was observed in bitterness reduction between xylitol and sucrose. Both reduced bitterness significantly more than maltodextrin. No interactions between the taste-masking agents affecting bitterness reduction were found. Clearer bitter-masking effects were seen in the aqueous model compared with the bread model. The bitter-masking effects of α-cyclodextrin and maltodextrin were similar between water and bread. The effect of xylitol and sucrose on bitterness suppression varied between the systems. In water, bitterness was negatively correlated with sweetness. In bread, bitterness was negatively correlated with freshness, and maltodextrin significantly reduced bitterness of the enzyme-treated soy protein and increased freshness. Bitter-masking effects were generally more discernible in the aqueous model compared with the bread model. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
NASA Technical Reports Server (NTRS)
Hampton, R. David; Whorton, Mark S.
2000-01-01
Many microgravity space-science experiments require active vibration isolation, to attain suitably low levels of background acceleration for useful experimental results. The design of state-space controllers by optimal control methods requires judicious choices of frequency-weighting design filters. Kinematic coupling among states greatly clouds designer intuition in the choices of these filters, and the masking effects of the state observations cloud the process further. Recent research into the practical application of H2 synthesis methods to such problems, indicates that certain steps can lead to state frequency-weighting design-filter choices with substantially improved promise of usefulness, even in the face of these difficulties. In choosing these filters on the states, one considers their relationships to corresponding design filters on appropriate pseudo-sensitivity- and pseudo-complementary-sensitivity functions. This paper investigates the application of these considerations to a single-degree-of-freedom microgravity vibration-isolation test case. Significant observations that were noted during the design process are presented. along with explanations based on the existent theory for such problems.
Tidoni, Emmanuele; Gergondet, Pierre; Fusco, Gabriele; Kheddar, Abderrahmane; Aglioti, Salvatore M
2017-06-01
The efficient control of our body and successful interaction with the environment are possible through the integration of multisensory information. Brain-computer interface (BCI) may allow people with sensorimotor disorders to actively interact in the world. In this study, visual information was paired with auditory feedback to improve the BCI control of a humanoid surrogate. Healthy and spinal cord injured (SCI) people were asked to embody a humanoid robot and complete a pick-and-place task by means of a visual evoked potentials BCI system. Participants observed the remote environment from the robot's perspective through a head mounted display. Human-footsteps and computer-beep sounds were used as synchronous/asynchronous auditory feedback. Healthy participants achieved better placing accuracy when listening to human footstep sounds relative to a computer-generated sound. SCI people demonstrated more difficulty in steering the robot during asynchronous auditory feedback conditions. Importantly, subjective reports highlighted that the BCI mask overlaying the display did not limit the observation of the scenario and the feeling of being in control of the robot. Overall, the data seem to suggest that sensorimotor-related information may improve the control of external devices. Further studies are required to understand how the contribution of residual sensory channels could improve the reliability of BCI systems.
Taki, Moeko; Tagami, Tatsuaki; Ozeki, Tetsuya
2017-05-01
The development of taste-masking technologies for foods and drugs is essential because it would enable people to consume and receive healthy and therapeutic effect without distress. In the current study, in order to develop a novel method to prepare nanocomposite particles (microparticles containing bitter nanoparticles) in only one step, by using spray drying, a two-solution mixing nozzle-equipped spray dryer that we previously reported was used. The nanocomposite particles with or without poorly water-soluble polymers prepared using our spray-drying technique were characterized. (1) The organic solution containing quinine, a model of bitter compound and poorly water-soluble polymers and (2) sugar alcohol (mannitol) aqueous solution were separately flown in tubes and two solutions were spray dried through two-solution type spray nozzle to prepare polymer-blended quinine nanocomposite particles. Mean diameters of nanoparticles, taste-masking effect and dissolution rate of quinine were evaluated. The results of taste masking by taste sensor suggested that the polymer (Eudragit EPO, Eudragit S100 or Ethyl cellulose)-blended quinine nanocomposite particles exhibited marked masking of instrumental quinine bitterness compared with the quinine nanocomposite particles alone. Quinine nanocomposite formulations altered the quinine dissolution rate, indicating that they can control intestinal absorption of quinine. These results suggest that polymer-blended quinine composite particles prepared using our spray-drying technique are useful for masking bitter tastes in the field of food and pharmaceutical industry.
The characteristics of bacterial nanocellulose gel releasing silk sericin for facial treatment.
Aramwit, Pornanong; Bang, Nipaporn
2014-12-09
Recently, naturally derived facial masks with beneficial biological properties have received increasing interest. In this study, silk sericin-releasing bacterial nanocellulose gel was developed to be applied as a bioactive mask for facial treatment. The silk sericin-releasing bacterial nanocellulose gel produced at a pH of 4.5 had an ultrafine and extremely pure fiber network structure. The mechanical properties and moisture absorption ability of the gel were improved, compared to those of the commercially available paper mask. Silk sericin could be control-released from the gel. A peel test with porcine skin showed that the gel was less adhesive than the commercially available paper mask, which would be removed from the face more easily without pain. The in vitro cytotoxicity test showed that the gel was not toxic to L929 mouse fibroblast and HaCaT human keratinocyte cells. Furthermore, when implanted subcutaneously and evaluated according to ISO10993-6 standard, the gel was not irritant to tissue. The silk sericin-releasing bacterial nanocellulose gel had appropriate physical and biological properties and safety for the facial treatment application.
EUVL masks: paving the path for commercialization
NASA Astrophysics Data System (ADS)
Mangat, Pawitter J. S.; Hector, Scott D.
2001-09-01
Optical projection lithography has been the principal vehicle of semiconductor manufacturing for more than 20 years and is marching aggressively to satisfy the needs of semiconductor manufacturers for 100nm devices. However, the complexity of optical lithography continues to increase as wavelength reduction continues to 157nm. Extreme Ultraviolet Lithography (EUVL), with wavelength from 13-14 nm, is evolving as a leading next generation lithography option for semiconductor industry to stay on the path laid by Moore's Law. Masks are a critical part of the success of any technology and are considered to be high risk both for optical lithography and NGL technologies for sub-100nm lithography. Two key areas of EUV mask fabrication are reflective multilayer deposition and absorber patterning. In the case of reflective multilayers, delivering defect free multilayers for mask blanks is the biggest challenge. Defect mitigation is being explored as a possible option to smooth the multilayer defects in addition to optimization of the deposition process to reduce defect density. The mask patterning process needs focus on the defect-free absorber stack patterning process, mask cleaning, inspection and repair. In addition, there is considerable effort to understand by simulations, the defect printability, thermal and mechanical distortions, and non-telecentric illumination, to mention a few. To protect the finished mask from defects added during use, a removable pellicle strategy combined with thermophoretic protection during exposure is being developed. Recent migration to square form factor using low thermal expansion material (LTEM) is advantageous as historical developments in optical masks can be applied to EUV mask patterning. This paper addresses recent developments in the EUV mask patterning and highlights critical manufacturing process controls needed to fabricate defect-free full field masks with CD and image placement specifications for sub-70nm node lithography. No technology can be implemented without establishing the commercial infrastructure. The rising cost seems to be a major issue affecting the technology development. With respect to mask fabrication for commercial availability, a virtual mask shop analysis is presented that indicates that the process cost for EUVL masks are comparable to the high end optical mask with a reasonable yield. However, the cost for setting up a new mask facility is considerably high.
2013-01-01
An intuitionistic method is proposed to design shadow masks to achieve thickness profile control for evaporation coating processes. The proposed method is based on the concept of the shadow matrix, which is a matrix that contains coefficients that build quantitive relations between shape parameters of masks and shadow quantities of substrate directly. By using the shadow matrix, shape parameters of shadow masks could be derived simply by solving a matrix equation. Verification experiments were performed on a special case where coating materials have different condensation characteristics. By using the designed mask pair with complementary shapes, thickness uniformities of better than 98% are demonstrated for MgF2 (m = 1) and LaF3 (m = 0.5) simultaneously on a 280 mm diameter spherical substrate with the radius curvature of 200 mm. PMID:24227996
Masking Period Patterns and Forward Masking for Speech-Shaped Noise: Age-Related Effects.
Grose, John H; Menezes, Denise C; Porter, Heather L; Griz, Silvana
2016-01-01
The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to nonsimultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Participants included younger (n = 11), middle-age (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions and assessed how well the temporal window fits accounted for these data. The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. This study demonstrated an age-related increase in susceptibility to nonsimultaneous masking, supporting the hypothesis that exacerbated nonsimultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data, suggesting an association between susceptibility to forward masking and speech understanding in modulated noise.
Controlling bridging and pinching with pixel-based mask for inverse lithography
NASA Astrophysics Data System (ADS)
Kobelkov, Sergey; Tritchkov, Alexander; Han, JiWan
2016-03-01
Inverse Lithography Technology (ILT) has become a viable computational lithography candidate in recent years as it can produce mask output that results in process latitude and CD control in the fab that is hard to match with conventional OPC/SRAF insertion approaches. An approach to solving the inverse lithography problem as a nonlinear, constrained minimization problem over a domain mask pixels was suggested in the paper by Y. Granik "Fast pixel-based mask optimization for inverse lithography" in 2006. The present paper extends this method to satisfy bridging and pinching constraints imposed on print contours. Namely, there are suggested objective functions expressing penalty for constraints violations, and their minimization with gradient descent methods is considered. This approach has been tested with an ILT-based Local Printability Enhancement (LPTM) tool in an automated flow to eliminate hotspots that can be present on the full chip after conventional SRAF placement/OPC and has been applied in 14nm, 10nm node production, single and multiple-patterning flows.
Rowland, Sharn; Aiyappan, Vinod; Hennessy, Cathy; Catcheside, Peter; Chai-Coezter, Ching Li; McEvoy, R Doug; Antic, Nick A
2018-01-15
To determine if the type of continuous positive airway pressure (CPAP) mask interface influences CPAP treatment efficacy, adherence, side effects, comfort and sleep quality in patients with moderate-severe obstructive sleep apnea (OSA). This took place in a hospital-based tertiary sleep disorders unit. It is a prospective, randomized, crossover trial comparing three CPAP interfaces: nasal mask (NM), nasal mask plus chinstrap (NM-CS) and oronasal mask (ONM) each tried in random order, for 4 weeks. After each 4-week period, patient outcomes were assessed. Participants had a new diagnosis of obstructive sleep apneas. Forty-eight patients with moderate-severe OSA (32 males, mean ± standard deviation apnea-hypopnea index (AHI) 55.6 ± 21.1 events/h, age 54.9 ± 13.1 years, body mass index 35.8 ± 7.2 kg/m 2 ) were randomized. Thirty-five participants completed the full study, with complete data available for 34 patients. There was no statistically significant difference in CPAP adherence; however, residual AHI was higher with ONM than NM and NM-CS (residual AHI 7.1 ± 7.7, 4.0 ± 3.1, 4.2 ± 3.7 events/h respectively, main effect P = .001). Patient satisfaction and quality of sleep were higher with the NM and NM-CS than the ONM. Fewer leak and mask fit problems were reported with NM (all chi-square P < .05), which patients preferred over the NM-CS and ONM options (n = 22, 9 and 4 respectively, P = .001). The CPAP adherence did not differ between the three different mask interfaces but the residual AHI was lower with NM than ONM and patients reported greater mask comfort, better sleep, and overall preference for a NM. A nasal mask with or without chinstrap should be the first choice for patients with OSA referred for CPAP treatment. Registry: Australian and New Zealand Clinical Trials Registry, URL: https://www.anzctr.org.au, title: A comparison of continuous positive airway pressure (CPAP) interface in the control of leak, patient compliance and patient preference: nasal CPAP mask and chinstrap versus full face mask in patients with obstructive sleep apnoea (OSA), identifier: ACTRN12609000029291. © 2018 American Academy of Sleep Medicine
Nievas-Cazorla, Francisco; Soriano-Ferrer, Manuel; Sánchez-López, Pilar
2016-01-01
The aim of this study was to compare the reaction times and errors of Spanish children with developmental dyslexia to the reaction times and errors of readers without dyslexia on a masked lexical decision task with identity or repetition priming. A priming paradigm was used to study the role of the lexical deficit in dyslexic children, manipulating the frequency and length of the words, with a short Stimulus Onset Asynchrony (SOA = 150 ms) and degraded stimuli. The sample consisted of 80 participants from 9 to 14 years old, divided equally into a group with a developmental dyslexia diagnosis and a control group without dyslexia. Results show that identity priming is higher in control children (133 ms) than in dyslexic children (55 ms). Thus, the "frequency" and "word length" variables are not the source or origin of this reduction in identity priming reaction times in children with developmental dyslexia compared to control children.
The bright-star masks for the HSC-SSP survey
NASA Astrophysics Data System (ADS)
Coupon, Jean; Czakon, Nicole; Bosch, James; Komiyama, Yutaka; Medezinski, Elinor; Miyazaki, Satoshi; Oguri, Masamune
2018-01-01
We present the procedure to build and validate the bright-star masks for the Hyper-Suprime-Cam Strategic Subaru Proposal (HSC-SSP) survey. To identify and mask the saturated stars in the full HSC-SSP footprint, we rely on the Gaia and Tycho-2 star catalogues. We first assemble a pure star catalogue down to GGaia < 18 after removing ˜1.5% of sources that appear extended in the Sloan Digital Sky Survey (SDSS). We perform visual inspection on the early data from the S16A internal release of HSC-SSP, finding that our star catalogue is 99.2% pure down to GGaia < 18. Second, we build the mask regions in an automated way using stacked detected source measurements around bright stars binned per GGaia magnitude. Finally, we validate those masks by visual inspection and comparison with the literature of galaxy number counts and angular two-point correlation functions. This version (Arcturus) supersedes the previous version (Sirius) used in the S16A internal and DR1 public releases. We publicly release the full masks and tools to flag objects in the entire footprint of the planned HSC-SSP observations at "ftp://obsftp.unige.ch/pub/coupon/brightStarMasks/HSC-SSP/".
Designing to win in sub-90nm mask production
NASA Astrophysics Data System (ADS)
Zhang, Yuan
2005-11-01
An informal survey conducted with key customers by Photronics indicates that the time gap between technology nodes has accelerated in recent years. Previously the cycle was three years. However, between 130nm and 90nm there was less than a 2 year gap, and between 90nm and 65nm a 1.5 year gap exists. As a result, the technical challenges have increased substantially. In addition, mask costs are rising exponentially due to high capital equipment cost, a shrinking customer base, long write times and increased applications of 193nm EAPSM or AAPSM. Collaboration among EDA companies, mask houses and wafer manufacturers is now more important than ever. This paper will explore avenues for reducing mask costs, mainly in the areas of: write-time reduction through design for manufacturing (DFM), and yield improvement through specification relaxation. Our study conducted through layout vertex modeling suggests that a simple design shape such as a square versus a circle or an angled structure helps reduce shot count and write time. Shot count reduction through mask layout optimization, and advancement in new generation E-beam writers can reduce write time up to 65%. An advanced laser writer can produce those less critical E-beam layers in less than half the time of an e-beam writer. Additionally, the emerging imprint lithography brings new life and new challenges to the photomask industry with applications in many fields outside of the semiconductor industry. As immersion lithography is introduced for 45nm device production, polarization and MEEF effects due to the mask will become severe. Larger magnification not only provides benefits on CD control and MEEF, but also extends the life time of current 90nm/65nm tool sets where 45nm mask sets can be produced at a lower cost.
Conceptual Masking: How One Picture Captures Attention from Another Picture.
ERIC Educational Resources Information Center
Loftus, Geoffrey R.; And Others
1988-01-01
Five experiments studied operations of conceptual masking--the reduction of conceptual memory performance for an initial stimulus when it is followed by a masking picture process. The subjects were 337 undergraduates at the University of Washington (Seattle). Conceptual masking is distinguished from perceptual masking. (TJH)
Jung, Mi; Kim, Jae Hun; Lee, Seok; Jang, Byung Jin; Lee, Woo Young; Oh, Yoo-Mi; Park, Sun-Woo; Woo, Deokha
2012-07-01
A significant enhancement in the light output from nano-patterned InP substrate covered with a nanoporous alumina mask was observed. A uniform nanohole array on an InP semiconductor substrate was fabricated by inductively coupled plasma reactive ion etching (ICP-RIE), using the nanoporous alumina mask as a shadow mask. The light output property of the semiconductor substrate was investigated via photoluminescence (PL) intensity measurement. The InP substrate with a nanohole array showed a more enhanced PL intensity compared with the raw InP substrate without a nanohole structure. After ICP-RIE etching, the light output from the nanoporous InP substrate covered with a nanoporous alumina mask showed fourfold enhanced PL intensity compared with the raw InP substrate. These results can be used as a prospective method for increasing the light output efficiency of optoelectronic devices.
NASA Astrophysics Data System (ADS)
Glasser, Joshua; Pratt, Tim
2008-10-01
Programmed defect test masks serve the useful purpose of evaluating inspection system sensitivity and capability. It is widely recognized that when evaluating inspection system capability, it is important to understand the actual sensitivity of the inspection system in production; yet unfortunately we have observed that many test masks are a more accurate judge of theoretical sensitivity rather than real-world usable capability. Use of ineffective test masks leave the purchaser of inspection equipment open to the risks of over-estimating the capability of their inspection solution and overspecifying defect sensitivity to their customers. This can result in catastrophic yield loss for device makers. In this paper we examine some of the lithography-related technology advances which place an increasing burden on mask inspection complexity, such as MEEF, defect printability estimation, aggressive OPC, double patterning, and OPC jogs. We evaluate the key inspection system component contributors to successful mask inspection, including what can "go wrong" with these components. We designed and fabricated a test mask which both (a) more faithfully represents actual production use cases; and (b) stresses the key components of the inspection system. This mask's patterns represent 32nm, 36nm, and 45nm logic and memory technology including metal and poly like background patterns with programmed defects. This test mask takes into consideration requirements of advanced lithography, such as MEEF, defect printability, assist features, nearly-repetitive patterns, and data preparation. This mask uses patterns representative of 32nm, 36nm, and 45nm logic, flash, and DRAM technology. It is specifically designed to have metal and poly like background patterns with programmed defects. The mask is complex tritone and was designed for annular immersion lithography.
Design Architecture of field-effect transistor with back gate electrode for biosensor application
NASA Astrophysics Data System (ADS)
Fathil, M. F. M.; Arshad, M. K. Md.; Hashim, U.; Ruslinda, A. R.; Gopinath, Subash C. B.; M. Nuzaihan M., N.; Ayub, R. M.; Adzhri, R.; Zaki, M.; Azman, A. H.
2016-07-01
This paper presents the preparation method of photolithography chrome mask design used in fabrication process of field-effect transistor with back gate biasing based biosensor. Initially, the chrome masks are designed by studying the process flow of the biosensor fabrication, followed by drawing of the actual chrome mask using the AutoCAD software. The overall width and length of the device is optimized at 16 mm and 16 mm, respectively. Fabrication processes of the biosensor required five chrome masks, which included source and drain formation mask, the back gate area formation mask, electrode formation mask, front gate area formation mask, and passivation area formation mask. The complete chrome masks design will be sent for chrome mask fabrication and for future use in biosensor fabrication.
Van Belle, Goedele; Busigny, Thomas; Lefèvre, Philippe; Joubert, Sven; Felician, Olivier; Gentile, Francesco; Rossion, Bruno
2011-09-01
Gaze-contingency is a method traditionally used to investigate the perceptual span in reading by selectively revealing/masking a portion of the visual field in real time. Introducing this approach in face perception research showed that the performance pattern of a brain-damaged patient with acquired prosopagnosia (PS) in a face matching task was reversed, as compared to normal observers: the patient showed almost no further decrease of performance when only one facial part (eye, mouth, nose, etc.) was available at a time (foveal window condition, forcing part-based analysis), but a very large impairment when the fixated part was selectively masked (mask condition, promoting holistic perception) (Van Belle, De Graef, Verfaillie, Busigny, & Rossion, 2010a; Van Belle, De Graef, Verfaillie, Rossion, & Lefèvre, 2010b). Here we tested the same manipulation in a recently reported case of pure prosopagnosia (GG) with unilateral right hemisphere damage (Busigny, Joubert, Felician, Ceccaldi, & Rossion, 2010). Contrary to normal observers, GG was also significantly more impaired with a mask than with a window, demonstrating impairment with holistic face perception. Together with our previous study, these observations support a generalized account of acquired prosopagnosia as a critical impairment of holistic (individual) face perception, implying that this function is a key element of normal human face recognition. Furthermore, the similar behavioral pattern of the two patients despite different lesion localizations supports a distributed network view of the neural face processing structures, suggesting that the key function of human face processing, namely holistic perception of individual faces, requires the activity of several brain areas of the right hemisphere and their mutual connectivity. Copyright © 2011 Elsevier Ltd. All rights reserved.
Emotion colors time perception unconsciously.
Yamada, Yuki; Kawabe, Takahiro
2011-12-01
Emotion modulates our time perception. So far, the relationship between emotion and time perception has been examined with visible emotional stimuli. The present study investigated whether invisible emotional stimuli affected time perception. Using continuous flash suppression, which is a kind of dynamic interocular masking, supra-threshold emotional pictures were masked or unmasked depending on whether the retinal position of continuous flashes on one eye was consistent with that of the pictures on the other eye. Observers were asked to reproduce the perceived duration of a frame stimulus that was concurrently presented with a masked or unmasked emotional picture. As a result, negative emotional stimuli elongated the perceived duration of the frame stimulus in comparison with positive and neutral emotional stimuli, regardless of the visibility of emotional pictures. These results suggest that negative emotion unconsciously accelerates an internal clock, altering time perception. Copyright © 2011 Elsevier Inc. All rights reserved.
Young, Laura K; Smithson, Hannah E
2014-01-01
There is evidence that letter identification is mediated by only a narrow band of spatial frequencies and that the center frequency of the neural channel thought to underlie this selectivity is related to the size of the letters. When letters are spatially filtered (at a fixed size) the channel tuning characteristics change according to the properties of the spatial filter (Majaj et al., 2002). Optical aberrations in the eye act to spatially filter the image formed on the retina-their effect is generally to attenuate high frequencies more than low frequencies but often in a non-monotonic way. We might expect the change in the spatial frequency spectrum caused by the aberration to predict the shift in channel tuning observed for aberrated letters. We show that this is not the case. We used critical-band masking to estimate channel-tuning in the presence of three types of aberration-defocus, coma and secondary astigmatism. We found that the maximum masking was shifted to lower frequencies in the presence of an aberration and that this result was not simply predicted by the spatial-frequency-dependent degradation in image quality, assessed via metrics that have previously been shown to correlate well with performance loss in the presence of an aberration. We show that if image quality effects are taken into account (using visual Strehl metrics), the neural channel required to model the data is shifted to lower frequencies compared to the control (no-aberration) condition. Additionally, we show that when spurious resolution (caused by π phase shifts in the optical transfer function) in the image is masked, the channel tuning properties for aberrated letters are affected, suggesting that there may be interference between visual channels. Even in the presence of simulated aberrations, whose properties change from trial-to-trial, observers exhibit flexibility in selecting the spatial frequencies that support letter identification.
Feasibility of retinoids for the treatment of emphysema study.
Roth, Michael D; Connett, John E; D'Armiento, Jeanine M; Foronjy, Robert F; Friedman, Paul J; Goldin, Jonathan G; Louis, Thomas A; Mao, Jenny T; Muindi, Josephia R; O'Connor, George T; Ramsdell, Joe W; Ries, Andrew L; Scharf, Steven M; Schluger, Neil W; Sciurba, Frank C; Skeans, Melissa A; Walter, Robert E; Wendt, Christine H; Wise, Robert A
2006-11-01
Retinoids promote alveolar septation in the developing lung and stimulate alveolar repair in some animal models of emphysema. One hundred forty-eight subjects with moderate-to-severe COPD and a primary component of emphysema, defined by diffusing capacity of the lung for carbon monoxide (Dlco) [37.1 +/- 12.0% of predicted] and CT density mask (38.5 +/- 12.8% of voxels <- 910 Hounsfield units) [mean +/- SD] were enrolled into a randomized, double-blind, feasibility study at five university hospitals. Participants received all-trans retinoic acid (ATRA) at either a low dose (LD) [1 mg/kg/d] or high dose (HD) [2 mg/kg/d], 13-cis retinoic acid (13-cRA) [1 mg/kg/d], or placebo for 6 months followed by a 3-month crossover period. No treatment was associated with an overall improvement in pulmonary function, CT density mask score, or health-related quality of life (QOL) at the end of 6 months. However, time-dependent changes in Dlco (initial decrease with delayed recovery) and St. George Respiratory Questionnaire (delayed improvement) were observed in the HD-ATRA cohort and correlated with plasma drug levels. In addition, 5 of 25 participants in the HD-ATRA group had delayed improvements in their CT scores that also related to ATRA levels. Retinoid-related side effects were common but generally mild. No definitive clinical benefits related to the administration of retinoids were observed in this feasibility study. However, time- and dose-dependent changes in Dlco, CT density mask score, and health-related QOL were observed in subjects treated with ATRA, suggesting the possibility of exposure-related biological activity that warrants further investigation.
X-ray mask and method for making
Morales, Alfredo M.
2004-10-26
The present invention describes a method for fabricating an x-ray mask tool which is a contact lithographic mask which can provide an x-ray exposure dose which is adjustable from point-to-point. The tool is useful in the preparation of LIGA plating molds made from PMMA, or similar materials. In particular the tool is useful for providing an ability to apply a graded, or "stepped" x-ray exposure dose across a photosensitive substrate. By controlling the x-ray radiation dose from point-to-point, it is possible to control the development process for removing exposed portions of the substrate; adjusting it such that each of these portions develops at a more or less uniformly rate regardless of feature size or feature density distribution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, T; Cho, M; Kang, S
Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with amore » head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less
Boiano, James M; Steege, Andrea L; Sweeney, Marie H
2017-06-01
Engineering, administrative, and work practice controls have been recommended for many years to minimize exposure to nitrous oxide during dental procedures. To better understand the extent to which these exposure controls are used, the NIOSH Health and Safety Practices Survey of Healthcare Workers was conducted among members of professional practice organizations representing dentists, dental hygienists and dental assistants. The anonymous, modular, web-based survey was completed by 284 dental professionals in private practice who administered nitrous oxide to adult and/or pediatric patients in the seven days prior to the survey. Use of primary engineering controls (i.e., nasal scavenging mask and/or local exhaust ventilation (LEV) near the patient's mouth) was nearly universal, reported by 93% and 96% of respondents who administered to adult (A) and pediatric (P) patients, respectively. However, adherence to other recommended precautionary practices were lacking to varying degrees, and were essentially no different among those administering nitrous oxide to adult or pediatric patients. Examples of work practices which increase exposure risk, expressed as percent of respondents, included: not checking nitrous oxide equipment for leaks (41% A; 48% P); starting nitrous oxide gas flow before delivery mask or airway mask was applied to patient (13% A; 12% P); and not turning off nitrous oxide gas flow before turning off oxygen flow to the patient (8% A; 7% P). Absence of standard procedures to minimize worker exposure to nitrous oxide (13% of all respondents) and not being trained on safe handling and administration of nitrous oxide (3%) were examples of breaches of administrative controls which may also increase exposure risk. Successful management of nitrous oxide emissions should include properly fitted nasal scavenging masks, supplemental LEV (when nitrous oxide levels cannot be adequately controlled using nasal masks alone), adequate general ventilation, regular inspection of nitrous oxide delivery and scavenging equipment for leaks, availability of standard procedures to minimize exposure, periodic training, ambient air and exposure monitoring, and medical surveillance.
Bonds, A B
1989-01-01
Mechanisms supporting orientation selectivity of cat striate cortical cells were studied by stimulation with two superimposed sine-wave gratings of different orientations. One grating (base) generated a discharge of known amplitude which could be modified by the second grating (mask). Masks presented at nonoptimal orientations usually reduced the base-generated response, but the degree of reduction varied widely between cells. Cells with narrow orientation tuning tended to be more susceptible to mask presence than broadly tuned cells; similarly, simple cells generally showed more response reduction than did complex cells. The base and mask stimuli were drifted at different temporal frequencies which, in simple cells, permitted the identification of individual response components from each stimulus. This revealed that the reduction of the base response by the mask usually did not vary regularly with mask orientation, although response facilitation from the mask was orientation selective. In some sharply tuned simple cells, response reduction had clear local maxima near the limits of the cell's orientation-tuning function. Response reduction resulted from a nearly pure rightward shift of the response versus log contrast function. The lowest mask contrast yielding reduction was within 0.1-0.3 log unit of the lowest contrast effective for excitation. The temporal-frequency bandpass of the response-reduction mechanism resembled that of most cortical cells. The spatial-frequency bandpass was much broader than is typical for single cortical cells, spanning essentially the entire visual range of the cat. These findings are compatible with a model in which weak intrinsic orientation-selective excitation is enhanced in two stages: (1) control of threshold by nonorientation-selective inhibition that is continuously dependent on stimulus contrast; and (2) in the more narrowly tuned cells, orientation-selective inhibition that has local maxima serving to increase the slope of the orientation-tuning function.
Haley, Katarina L.
2015-01-01
Purpose To study the effects of masked auditory feedback (MAF) on speech fluency in adults with aphasia and/or apraxia of speech (APH/AOS). We hypothesized that adults with AOS would increase speech fluency when speaking with noise. Altered auditory feedback (AAF; i.e., delayed/frequency-shifted feedback) was included as a control condition not expected to improve speech fluency. Method Ten participants with APH/AOS and 10 neurologically healthy (NH) participants were studied under both feedback conditions. To allow examination of individual responses, we used an ABACA design. Effects were examined on syllable rate, disfluency duration, and vocal intensity. Results Seven of 10 APH/AOS participants increased fluency with masking by increasing rate, decreasing disfluency duration, or both. In contrast, none of the NH participants increased speaking rate with MAF. In the AAF condition, only 1 APH/AOS participant increased fluency. Four APH/AOS participants and 8 NH participants slowed their rate with AAF. Conclusions Speaking with MAF appears to increase fluency in a subset of individuals with APH/AOS, indicating that overreliance on auditory feedback monitoring may contribute to their disorder presentation. The distinction between responders and nonresponders was not linked to AOS diagnosis, so additional work is needed to develop hypotheses for candidacy and underlying control mechanisms. PMID:26363508
Evaluation of a New Pediatric Positive Airway Pressure Mask
Kushida, Clete A.; Halbower, Ann C.; Kryger, Meir H.; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J.; Mendoza, June
2014-01-01
Study Objectives: The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged < 7 years was not available. This study evaluated apnea-hypopnea index (AHI) equivalence and acceptability of a new pediatric CPAP mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Methods: Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. Results: AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. Conclusions: The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. Citation: Kushida CA, Halbower AC, Kryger MH, Pelayo R, Assalone V, Cardell CY, Huston S, Willes L, Wimms AJ, Mendoza J. Evaluation of a new pediatric positive airway pressure mask. J Clin Sleep Med 2014;10(9):979-984. PMID:25142768
Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.
2010-01-01
Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α = .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20 = 48.87, P = .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20 = 16.25, P = .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F4,20 = 43.20, P = .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. Conclusions: The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated. PMID:21062179
NASA Astrophysics Data System (ADS)
Hansen, Matthew E.; Cerrina, Franco
1994-05-01
A high-sensitivity holographic and interferometric metrology developed at the Center for X- ray Lithography (CXrL) has been employed to investigate in-plane distortions (IPD) produced in x-ray mask materials. This metrology has been applied to characterize damage to x-ray mask materials exposed to synchrotron radiation. X-ray mask damage and accelerated mask damage studies on silicon nitride and silicon carbide were conducted on the Aladdin ES-1 and ES-2 beamline exposure stations, respectively. Accumulated in-plane distortions due to x-ray irradiation were extracted from the incremental interferometric phase maps to yield IPD vs. dose curves for silicon nitride mask blanks. Silicon carbide mask blanks were subjected to accelerated mask damage in the high flux 2 mm X 2 mm beam of the ES-2 exposure station. An accelerated damage study of silicon carbide has shown no in-plane distortion for an accumulated dose of 800 kJ/cm2 with a measurement sensitivity of less than 5 nm.
Baroreceptors mask sympathetic responses to high intraocular pressure in dogs.
Yahagi, Toru; Koyama, Shozo; Osaka, Kazumasa; Koyama, Haruhide
2008-05-30
These experiments were designed to investigate whether increasing intraocular pressure (IOP) in anesthetized dogs produces differential control of sympathetic nerve activities to various organs (heart, kidney, liver, and spleen) and if these sympathetic responses are modified by baroreceptors. We performed simultaneous multi-recordings of cardiac, renal, hepatic and splenic sympathetic nerve activities (CNA, RNA, HNA and SpNA, respectively) during 2 min of increasing IOP to a mean pressure of 30 mmHg. After increasing IOP in dogs with the intact baroreceptors, all of measured nerve activities did not change significantly throughout the experiment. In dogs with denervation of baroreceptors (cervical vagotomy with denervation of the carotid sinus and aortic nerves), only RNA and CNA showed significant increases in response to the increased IOP. However, time course changes in HNA and SpNA did not show any significant differences as compared with the baseline or that of the control group. These results indicate that systemic sympathetic nerve responses to increasing IOP are masked by systemic baroreceptors. As animals were denervated of their systemic baroreceptors, the unidirectional sympathoexcitatory responses to increased IOP were observed on CNA and RNA, but not on HNA and SpNA. These sympathetic outflow, when systemic baroreceptors are impaired as observed in old age, may play an important role in management of glaucoma attack with the use of adrenolytic drugs.
1989-10-06
spent pumice cleaning. All parts can be pumice cleaned faster by using the method described in Quick Fix Plan paragraph 6.0. Soaking the scrubbed masked...times were run at an unusuall fast pace. For two other days workers were observed masking parts and by excluding the time spent talking and working on...stop-off Lacquer, MICCROSTOP REDUCER is recom. mended. Also, a shot soak in caustic cleaner, both at 212’ F., will break the adhesion and the coating is
MEG masked priming evidence for form-based decomposition of irregular verbs
Fruchter, Joseph; Stockall, Linnaea; Marantz, Alec
2013-01-01
To what extent does morphological structure play a role in early processing of visually presented English past tense verbs? Previous masked priming studies have demonstrated effects of obligatory form-based decomposition for genuinely affixed words (teacher-TEACH) and pseudo-affixed words (corner-CORN), but not for orthographic controls (brothel-BROTH). Additionally, MEG single word reading studies have demonstrated that the transition probability from stem to affix (in genuinely affixed words) modulates an early evoked response known as the M170; parallel findings have been shown for the transition probability from stem to pseudo-affix (in pseudo-affixed words). Here, utilizing the M170 as a neural index of visual form-based morphological decomposition, we ask whether the M170 demonstrates masked morphological priming effects for irregular past tense verbs (following a previous study which obtained behavioral masked priming effects for irregulars). Dual mechanism theories of the English past tense predict a rule-based decomposition for regulars but not for irregulars, while certain single mechanism theories predict rule-based decomposition even for irregulars. MEG data was recorded for 16 subjects performing a visual masked priming lexical decision task. Using a functional region of interest (fROI) defined on the basis of repetition priming and regular morphological priming effects within the left fusiform and inferior temporal regions, we found that activity in this fROI was modulated by the masked priming manipulation for irregular verbs, during the time window of the M170. We also found effects of the scores generated by the learning model of Albright and Hayes (2003) on the degree of priming for irregular verbs. The results favor a single mechanism account of the English past tense, in which even irregulars are decomposed into stems and affixes prior to lexical access, as opposed to a dual mechanism model, in which irregulars are recognized as whole forms. PMID:24319420
Focal Suppression of Distractor Sounds by Selective Attention in Auditory Cortex.
Schwartz, Zachary P; David, Stephen V
2018-01-01
Auditory selective attention is required for parsing crowded acoustic environments, but cortical systems mediating the influence of behavioral state on auditory perception are not well characterized. Previous neurophysiological studies suggest that attention produces a general enhancement of neural responses to important target sounds versus irrelevant distractors. However, behavioral studies suggest that in the presence of masking noise, attention provides a focal suppression of distractors that compete with targets. Here, we compared effects of attention on cortical responses to masking versus non-masking distractors, controlling for effects of listening effort and general task engagement. We recorded single-unit activity from primary auditory cortex (A1) of ferrets during behavior and found that selective attention decreased responses to distractors masking targets in the same spectral band, compared with spectrally distinct distractors. This suppression enhanced neural target detection thresholds, suggesting that limited attention resources serve to focally suppress responses to distractors that interfere with target detection. Changing effort by manipulating target salience consistently modulated spontaneous but not evoked activity. Task engagement and changing effort tended to affect the same neurons, while attention affected an independent population, suggesting that distinct feedback circuits mediate effects of attention and effort in A1. © The Author 2017. Published by Oxford University Press.
Masking Period Patterns & Forward Masking for Speech-Shaped Noise: Age-related effects
Grose, John H.; Menezes, Denise C.; Porter, Heather L.; Griz, Silvana
2015-01-01
Objective The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to non-simultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Design Participants included younger (n = 11), middle-aged (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions, and assessed how well the temporal window fits accounted for these data. Results The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. Conclusions This study demonstrated an age-related increase in susceptibility to non-simultaneous masking, supporting the hypothesis that exacerbated non-simultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data suggesting an association between susceptibility to forward masking and speech understanding in modulated noise. PMID:26230495
Masking of a circadian behavior in larval zebrafish involves the thalamo-habenula pathway.
Lin, Qian; Jesuthasan, Suresh
2017-06-22
Changes in illumination can rapidly influence behavior that is normally controlled by the circadian clock. This effect is termed masking. In mice, masking requires melanopsin-expressing retinal ganglion cells that detect blue light and project to the thalamus. It is not known whether masking is wavelength-dependent in other vertebrates, nor is it known whether the thalamus is also involved or how it influences masking. Here, we address these questions in zebrafish. We find that diel vertical migration, a circadian behavior in larval zebrafish, is effectively triggered by blue, but not by red light. Two-photon calcium imaging reveals that a thalamic nucleus and a downstream structure, the habenula, have a sustained response to blue but not to red light. Lesioning the habenula reduces light-evoked climbing. These data suggest that the thalamo-habenula pathway is involved in the ability of blue light to influence a circadian behavior.
Mask-Assisted Seeded Growth of Segmented Metallic Heteronanostructures
Crane, Cameron C.; Tao, Jing; Wang, Feng; ...
2014-12-04
Controlling the deposition of exotic metals in the seeded growth of multi-metal nanostructures is challenging. This work describes a seeded growth method assisted by a mask for synthesis of segmented binary or ternary metal nanostructures. Silica is used as a mask to partially block the surface of a seed and a second metal is subsequently deposited on the exposed area, forming a bimetallic heterodimer. The initial demonstration was carried out on a Au seed, followed by deposition of Pd or Pt on the seed. It was found that Pd tends to spread out laterally on the seed while Pt inclinesmore » to grow vertically into branched topology on Au. Without removal of the SiO₂ mask, Pt could be further deposited on the unblocked Pd of the Pd-Au dimer to form a Pt-Pd-Au trimer. The mask-assisted seeded growth provides a general strategy to construct segmented metallic nanoarchitectures.« less
Post-conflict slowing: cognitive adaptation after conflict processing.
Verguts, Tom; Notebaert, Wim; Kunde, Wilfried; Wühr, Peter
2011-02-01
The aftereffects of error and conflict (i.e., stimulus or response incongruency) have been extensively studied in the cognitive control literature. Each has been characterized by its own behavioral signature on the following trial. Conflict leads to a reduced congruency effect (Gratton effect), whereas an error leads to increased response time (post-error slowing). The reason for this dissociation has remained unclear. Here, we show that post-conflict slowing is not typically observed because it is masked by the processing of the irrelevant stimulus dimension. We demonstrate that post-conflict slowing does occur when tested in pure trials where helpful or detrimental impacts from irrelevant stimulus dimensions are removed (i.e., univalent stimuli).
Shi, Nian-Qiu; Qi, Xian-Rong
2017-03-29
Cell-penetrating peptide (CPP), also called "Trojan Horse" peptide, has become a successful approach to deliver various payloads into cells for achieving the intracellular access. However, the "Trojan Horse" peptide is too wild, not just to "Troy", but rather widely distributed in the body. Thus, there is an urgent need to tame the wildness of "Trojan Horse" peptide for targeted delivery of antineoplastic agents to the tumor site. To achieve this goal, we exploit a masked CPP-doxorubicin conjugate platform for targeted delivery of chemotherapeutic drugs using charge-guided masking and protease-triggered demasking strategies. In this platform, the cell-penetrating function of the positively CPP (d-form nonaarginine) is abrogated by a negatively shielding peptide (masked CPP), and between them is a cleavable substrate peptide by the protease (MMP-2/9). Protease-triggered demasking would occur when the masked CPP reached the MMP-2/9-riched tumor. The CPP-doxorubicin conjugate (CPP-Dox) and the masked CPP-Dox conjugate (mCPP-Dox) were used as models for the evaluation of masking and demasking processes. It was found that exogenous MMP-2/9 could effectively trigger the reversion of CPP-cargo in this conjugate, and this trigger adhered to the Michaelis-Menten kinetics profile. This conjugate was sensitive to the trigger of endogenous MMP-2/9 and could induce enhanced cytotoxicity toward MMP-2/9-rich tumor cells. In vivo antitumor efficacy revealed that this masked conjugate had considerable antitumor activity and could inhibit the tumor growth at a higher level relative to CPP-cargo. Low toxicity in vivo showed the noticeably decreased wildness of this conjugate toward normal tissues and more controllable entry of antitumor agents into "Troy". On the basis of analyses in vitro and in vivo, this mCPP-cargo conjugate delivery system held an improved selectivity toward MMP-2/9-rich tumors and would be a promising strategy for tumor-targeted treatment.
Effectiveness of three just-in-time training modalities for N-95 mask fit testing.
Jones, David; Stoler, Genevieve; Suyama, Joe
2013-01-01
To compare and contrast three different training modalities for fit testing N-95 respirator face masks. Block randomized interventional study. Urban university. Two hundred eighty-nine medical students. Students were randomly assigned to video, lecture, or slide show to evaluate the effectiveness of the methods for fit testing large groups of people. Ease of fit and success of fit for each instructional technique. Mask 1 was a Kimberly-Clark duckbill N-95 respirator mask, and mask 2 was a 3M™ carpenters N-95 respirator mask. "Ease of fit" was defined as the ability to successfully don a mask in less than 30 seconds. "Success of fit" was defined as the ability to correctly don a mask in one try. There were no statistical differences by training modality for either mask regarding ease of fit or success of fit. There were no differences among video presentation, small group demonstration, and self-directed slide show just-in-time training modalities for ease of fit or success of fit N-95 respirator mask fitting. Further study is needed to explore more effective fit training modalities.
EUVL mask patterning with blanks from commercial suppliers
NASA Astrophysics Data System (ADS)
Yan, Pei-Yang; Zhang, Guojing; Nagpal, Rajesh; Shu, Emily Y.; Li, Chaoyang; Qu, Ping; Chen, Frederick T.
2004-12-01
Extreme Ultraviolet Lithography (EUVL) reflective mask blank development includes low thermal expansion material fabrication, mask substrate finishing, reflective multi-layer (ML) and capping layer deposition, buffer (optional)/absorber stack deposition, EUV specific metrology, and ML defect inspection. In the past, we have obtained blanks deposited with various layer stacks from several vendors. Some of them are not commercial suppliers. As a result, the blank and patterned mask qualities are difficult to maintain and improve. In this paper we will present the evaluation results of the EUVL mask pattering processes with the complete EUVL mask blanks supplied by the commercial blank supplier. The EUVL mask blanks used in this study consist of either quartz or ULE substrates which is a type of low thermal expansion material (LTEM), 40 pairs of molybdenum/silicon (Mo/Si) ML layer, thin ruthenium (Ru) capping layer, tantalum boron nitride (TaBN) absorber, and chrome (Cr) backside coating. No buffer layer is used. Our study includes the EUVL mask blank characterization, patterned EUVL mask characterization, and the final patterned EUVL mask flatness evaluation.
Roverud, Elin; Strickland, Elizabeth A
2014-03-01
The mechanisms of forward masking are not clearly understood. The temporal window model (TWM) proposes that masking occurs via a neural mechanism that integrates within a temporal window. The medial olivocochlear reflex (MOCR), a sound-evoked reflex that reduces cochlear amplifier gain, may also contribute to forward masking if the preceding sound reduces gain for the signal. Psychophysical evidence of gain reduction can be observed using a growth of masking (GOM) paradigm with an off-frequency forward masker and a precursor. The basilar membrane input/output (I/O) function is estimated from the GOM function, and the I/O function gain is reduced by the precursor. In this study, the effect of precursor duration on this gain reduction effect was examined for on- and off-frequency precursors. With on-frequency precursors, thresholds increased with increasing precursor duration, then decreased (rolled over) for longer durations. Thresholds with off-frequency precursors continued to increase with increasing precursor duration. These results are not consistent with solely neural masking, but may reflect gain reduction that selectively affects on-frequency stimuli. The TWM was modified to include history-dependent gain reduction to simulate the MOCR, called the temporal window model-gain reduction (TWM-GR). The TWM-GR predicted rollover and the differences with on- and off-frequency precursors whereas the TWM did not.
Efficacy of a heat exchanger mask in cold exercise-induced asthma.
Beuther, David A; Martin, Richard J
2006-05-01
To determine the efficacy of a novel mask device in limiting cold air exercise-induced decline in lung function in subjects with a history of exercise-induced asthma (EIA). In spite of appropriate medical therapy, many asthma patients are limited in cold weather activities. In study 1, 13 asthmatic subjects performed two randomized, single-blind treadmill exercise tests while breathing cold air (- 25 to - 15 degrees C) through a placebo or active heat exchanger mask. In study 2, five subjects with EIA performed three treadmill exercise tests while breathing cold air: one test using the heat exchanger mask, one test without the mask but with albuterol pretreatment, and one test with neither the mask nor albuterol pretreatment (unprotected exercise). For all studies, spirometry was performed before and at 5, 15, and 30 min after exercise challenge. For both studies, a total of 15 subjects with a history of asthma symptoms during cold air exercise were recruited. In study 1, the mean decrease (+/- SE) in FEV1 was 19 +/- 4.9% with placebo, and 4.3 +/- 1.6% with the active device (p = 0.0002). The mean decrease in maximum mid-expiratory flow (FEF(25-75)) was 31 +/- 5.7% with placebo and 4.7 +/- 1.7% with the active device (p = 0.0002). In study 2, the mean decrease in FEV1 was 6.3 +/- 3.9%, 11 +/- 3.7%, and 28 +/- 10% for the heat exchanger mask, albuterol pretreatment, and unprotected exercises, respectively (p = 0.4375 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). The mean decrease in FEF(25-75) was 10 +/- 4.8%, 23 +/- 6.0%, and 36 +/- 11%, respectively (p = 0.0625 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). This heat exchanger mask blocks cold exercise-induced decline in lung function at least as effectively as albuterol pretreatment.
Defect reduction of high-density full-field patterns in jet and flash imprint lithography
NASA Astrophysics Data System (ADS)
Singh, Lovejeet; Luo, Kang; Ye, Zhengmao; Xu, Frank; Haase, Gaddi; Curran, David; LaBrake, Dwayne; Resnick, Douglas; Sreenivasan, S. V.
2011-04-01
Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Jet and Flash Imprint Lithography (J-FIL) involves the field-by-field deposition and exposure of a low viscosity resist deposited by jetting technology onto the substrate. The patterned mask is lowered into the fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed leaving a patterned resist on the substrate. Acceptance of imprint lithography for manufacturing will require demonstration that it can attain defect levels commensurate with the defect specifications of high end memory devices. Typical defectivity targets are on the order of 0.10/cm2. This work summarizes the results of defect inspections focusing on two key defect types; random non-fill defects occurring during the resist filling process and repeater defects caused by interactions with particles on the substrate. Non-fill defectivity must always be considered within the context of process throughput. The key limiting throughput step in an imprint process is resist filling time. As a result, it is critical to characterize the filling process by measuring non-fill defectivity as a function of fill time. Repeater defects typically have two main sources; mask defects and particle related defects. Previous studies have indicated that soft particles tend to cause non-repeating defects. Hard particles, on the other hand, can cause either resist plugging or mask damage. In this work, an Imprio 500 twenty wafer per hour (wph) development tool was used to study both defect types. By carefully controlling the volume of inkjetted resist, optimizing the drop pattern and controlling the resist fluid front during spreading, fill times of 1.5 seconds were achieved with non-fill defect levels of approximately 1.2/cm2. Longevity runs were used to study repeater defects and a nickel contamination was identified as the key source of particle induced repeater defects.
Wise, Robert A; Bartlett, Susan J; Brown, Ellen D; Castro, Mario; Cohen, Rubin; Holbrook, Janet T; Irvin, Charles G; Rand, Cynthia S; Sockrider, Marianna M; Sugar, Elizabeth A
2009-09-01
Information that enhances expectations about drug effectiveness improves the response to placebos for pain. Although asthma symptoms often improve with placebo, it is not known whether the response to placebo or active treatment can be augmented by increasing expectation of benefit. The study objective was to determine whether response to placebo or a leukotriene antagonist (montelukast) can be augmented by messages that increase expectation of benefit. A randomized 20-center controlled trial enrolled 601 asthmatic patients with poor symptom control who were assigned to one of 5 study groups. Participants were randomly assigned to one of 4 treatment groups in a factorial design (ie, placebo with enhanced messages, placebo with neutral messages, montelukast with enhanced messages, or montelukast with neutral messages) or to usual care. Assignment to study drug was double masked, assignment to message content was single masked, and usual care was not masked. The enhanced message aimed to increase expectation of benefit from the drug. The primary outcome was mean change in daily peak flow over 4 weeks. Secondary outcomes included lung function and asthma symptom control. Peak flow and other lung function measures were not improved in participants assigned to the enhanced message groups versus the neutral messages groups for either montelukast or placebo; no differences were noted between the neutral placebo and usual care groups. Placebo-treated participants had improved asthma control with the enhanced message but not montelukast-treated participants; the neutral placebo group did have improved asthma control compared with the usual care group after adjusting for baseline difference. Headaches were more common in participants provided messages that mentioned headache as a montelukast side effect. Optimistic drug presentation augments the placebo effect for patient-reported outcomes (asthma control) but not lung function. However, the effect of montelukast was not enhanced by optimistic messages regarding treatment effectiveness.
Rafferty, Anthony Richard; Johnson, Lucy; Davis, Peter G; Dawson, Jennifer Anne; Thio, Marta; Owen, Louise S
2017-11-30
Neonatal mask ventilation is a difficult skill to acquire and maintain. Mask leak is common and can lead to ineffective ventilation. The aim of this study was to determine whether newly available neonatal self-inflating bags and masks could reduce mask leak without additional load being applied to the face. Forty operators delivered 1 min episodes of mask ventilation to a mannequin using the Laerdal Upright Resuscitator, a standard Laerdal infant resuscitator (Laerdal Medical) and a T-Piece Resuscitator (Neopuff), using both the Laerdal snap-fit face mask and the standard Laerdal size 0/1 face mask (equivalent sizes). Participants were asked to use pressure sufficient to achieve 'appropriate' chest rise. Leak, applied load, airway pressure and tidal volume were measured continuously. Participants were unaware that load was being recorded. There was no difference in mask leak between resuscitation devices. Leak was significantly lower when the snap-fit mask was used with all resuscitation devices, compared with the standard mask (14% vs 37% leak, P<0.01). The snap-fit mask was preferred by 83% of participants. The device-mask combinations had no significant effect on applied load. The Laerdal Upright Resuscitator resulted in similar leak to the other resuscitation devices studied, and did not exert additional load to the face and head. The snap-fit mask significantly reduced overall leak with all resuscitation devices and was the mask preferred by participants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Adelborg, K; Bjørnshave, K; Mortensen, M B; Espeseth, E; Wolff, A; Løfgren, B
2014-07-01
Thirty surf lifeguards (mean (SD) age: 25.1 (4.8) years; 21 male, 9 female) were randomly assigned to perform 2 × 3 min of cardiopulmonary resuscitation on a manikin using mouth-to-face-shield ventilation (AMBU LifeKey) and mouth-to-pocket-mask ventilation (Laerdal Pocket Mask). Interruptions in chest compressions, effective ventilation (visible chest rise) ratio, tidal volume and inspiratory time were recorded. Interruptions in chest compressions per cycle were increased with mouth-to-face-shield ventilation (mean (SD) 8.6 (1.7) s) compared with mouth-to-pocket-mask ventilation (6.9 (1.2) s, p < 0.0001). The proportion of effective ventilations was less using mouth-to-face-shield ventilation (199/242 (82%)) compared with mouth-to-pocket-mask ventilation (239/240 (100%), p = 0.0002). Tidal volume was lower using mouth-to-face-shield ventilation (mean (SD) 0.36 (0.20) l) compared with mouth-to-pocket-mask ventilation (0.45 (0.20) l, p = 0.006). No differences in inspiratory times were observed between mouth-to-face-shield ventilation and mouth-to-pocket-mask ventilation. In conclusion, mouth-to-face-shield ventilation increases interruptions in chest compressions, reduces the proportion of effective ventilations and decreases delivered tidal volumes compared with mouth-to-pocket-mask ventilation. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Masking of low-frequency signals by high-frequency, high-level narrow bands of noisea
Patra, Harisadhan; Roup, Christina M.; Feth, Lawrence L.
2011-01-01
Low-frequency masking by intense high-frequency noise bands, referred to as remote masking (RM), was the first evidence to challenge energy-detection models of signal detection. Its underlying mechanisms remain unknown. RM was measured in five normal-hearing young-adults at 250, 350, 500, and 700 Hz using equal-power, spectrally matched random-phase noise (RPN) and low-noise noise (LNN) narrowband maskers. RM was also measured using equal-power, two-tone complex (TC2) and eight-tone complex (TC8). Maskers were centered at 3000 Hz with one or two equivalent rectangular bandwidths (ERBs). Masker levels varied from 80 to 95 dB sound pressure level in 5 dB steps. LNN produced negligible masking for all conditions. An increase in bandwidth in RPN yielded greater masking over a wider frequency region. Masking for TC2 was limited to 350 and 700 Hz for one ERB but shifted to only 700 Hz for two ERBs. A spread of masking to 500 and 700 Hz was observed for TC8 when the bandwidth was increased from one to two ERBs. Results suggest that high-frequency noise bands at high levels could generate significant low-frequency masking. It is possible that listeners experience significant RM due to the amplification of various competing noises that might have significant implications for speech perception in noise. PMID:21361445
Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy
NASA Technical Reports Server (NTRS)
Newman, Kevin Edward; Belikov, Ruslan; Guyon, Olivier; Balasubramanian, Kunjithapatham; Wilson, Dan
2013-01-01
Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.
Bousquet, J; Devillier, P; Arnavielhe, S; Bedbrook, A; Alexis-Alexandre, G; van Eerd, M; Murray, R; Canonica, G W; Illario, M; Menditto, E; Passalacqua, G; Stellato, C; Triggiani, M; Carreiro-Martins, P; Fonseca, J; Morais Almeida, M; Nogueira-Silva, L; Pereira, A M; Todo Bom, A; Bosse, I; Caimmi, D; Demoly, P; Fontaine, J F; Just, J; Onorato, G L; Kowalski, M L; Kuna, P; Samolinski, B; Anto, J M; Mullol, J; Valero, A; Tomazic, P V; Bergmann, K C; Keil, T; Klimek, L; Mösges, R; Shamai, S; Zuberbier, T; Murphy, E; McDowall, P; Price, D; Ryan, D; Sheikh, A; Chavannes, N H; Fokkens, W J; Kvedariene, V; Valiulis, A; Bachert, C; Hellings, P W; Kull, I; Melen, E; Wickman, M; Bindslev-Jensen, C; Eller, E; Haahtela, T; Papadopoulos, N G; Annesi-Maesano, I; Bewick, M; Bosnic-Anticevich, S; Cruz, A A; De Vries, G; Gemicioglu, B; Larenas-Linnemann, D; Laune, D; Mathieu-Dupas, E; O'Hehir, R E; Pfaar, O; Portejoie, F; Siroux, V; Spranger, O; Valovirta, E; VandenPlas, O; Yorgancioglu, A
2018-01-15
Large observational implementation studies are needed to triangulate the findings from randomized control trials as they reflect "real-world" everyday practice. In a pilot study, we attempted to provide additional and complementary insights on the real-life treatment of allergic rhinitis (AR) using mobile technology. A mobile phone app (Allergy Diary, freely available in Google Play and Apple App stores) collects the data of daily visual analog scales (VAS) for (i) overall allergic symptoms, (ii) nasal, ocular, and asthma symptoms, (iii) work, as well as (iv) medication use using a treatment scroll list including all medications (prescribed and over the counter (OTC)) for rhinitis customized for 15 countries. A total of 2871 users filled in 17 091 days of VAS in 2015 and 2016. Medications were reported for 9634 days. The assessment of days appeared to be more informative than the course of the treatment as, in real life, patients do not necessarily use treatment on a daily basis; rather, they appear to increase treatment use with the loss of symptom control. The Allergy Diary allowed differentiation between treatments within or between classes (intranasal corticosteroid use containing medications and oral H1-antihistamines). The control of days differed between no [best control], single, or multiple treatments (worst control). This study confirms the usefulness of the Allergy Diary in accessing and assessing everyday use and practice in AR. This pilot observational study uses a very simple assessment (VAS) on a mobile phone, shows novel findings, and generates new hypotheses. © 2018 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.
STS-26 Pilot Covey, wearing sleep mask, rests on aft flight deck
NASA Technical Reports Server (NTRS)
1988-01-01
STS-26 Pilot Richard O. Covey, wearing sleep mask (blindfold) and a headset, props his feet under the pilots seat and rests his head and back on the aft flight deck onorbit station panels while he sleeps. At Covey's right are the mission station control panels.
Suslow, Thomas; Kugel, Harald; Lindner, Christian; Dannlowski, Udo; Egloff, Boris
2017-01-06
Extraversion-introversion is a personality dimension referring to individual differences in social behavior. In the past, neurobiological research on extraversion was almost entirely based upon questionnaires which inform about the explicit self-concept. Today, indirect measures are available that tap into the implicit self-concept of extraversion which is assumed to result from automatic processing functions. In our study, brain activation while viewing facial expression of affiliation relevant (i.e., happiness, and disgust) and irrelevant (i.e., fear) emotions was examined as a function of the implicit and explicit self-concept of extraversion and processing mode (automatic vs. controlled). 40 healthy volunteers watched blocks of masked and unmasked emotional faces while undergoing functional magnetic resonance imaging. The Implicit Association Test and the NEO Five-Factor Inventory were applied as implicit and explicit measures of extraversion which were uncorrelated in our sample. Implicit extraversion was found to be positively associated with neural response to masked happy faces in the thalamus and temporo-parietal regions and to masked disgust faces in cerebellar areas. Moreover, it was positively correlated with brain response to unmasked disgust faces in the amygdala and cortical areas. Explicit extraversion was not related to brain response to facial emotions when controlling trait anxiety. The implicit compared to the explicit self-concept of extraversion seems to be more strongly associated with brain activation not only during automatic but also during controlled processing of affiliation relevant facial emotions. Enhanced neural response to facial disgust could reflect high sensitivity to signals of interpersonal rejection in extraverts (i.e., individuals with affiliative tendencies). Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.
VizieR Online Data Catalog: Velocities in ZwCl2341.1+0000 field (Boschin+, 2013)
NASA Astrophysics Data System (ADS)
Boschin, W.; Girardi, M.; Barrena, R.
2014-07-01
Multi-object spectroscopic observations of ZwCl 2341+00 were carried out at the TNG in 2009 October, 2011 August and 2011 December. We used the instrument Device Optimized for the Low Resolution (DOLORES) in multi-object spectroscopy (MOS) mode with the LR-B Grism. In summary, we observed four MOS masks for a total of 142 slits. The total exposure time was 3600s for three masks and 5400s for the last one. (1 data file).
VizieR Online Data Catalog: Velocity catalog of A545 galaxies (Barrena+, 2011)
NASA Astrophysics Data System (ADS)
Barrena, R.; Girardi, M.; Boschin, W.; de Grandi, S.; Eckert, D.; Rossetti, M.
2011-08-01
Multi-object spectroscopic observations of A545 were carried out at the TNG telescope in October 2009. We used DOLORES/MOS with the LR-B Grism 1, yielding a dispersion of 187Å/mm. We used the new 2048x2048pixels E2V CCD, with a pixel size of 13.5um. In total, we observed 4 MOS masks for a total of 142 slits. We acquired three exposures of 1200s for each mask. (1 data file).
Kuyinu, Y A; Mohammed, A S; Adeyeye, O O; Odugbemi, B A; Goodman, O O; Odusanya, O O
2016-03-15
Tuberculosis infection among health care workers is capable of worsening the existing health human resource problems of low--and middle-income countries. Tuberculosis infection control is often weakly implemented in these parts of the world therefore, understanding the reasons for poor implementation of tuberculosis infection control guidelines are important. This study was aimed at assessing tuberculosis infection control practices and barriers to its implementation in Ikeja, Nigeria. A cross-sectional study in 20 tuberculosis care facilities (16 public and 4 private) in Ikeja, Lagos was conducted. The study included a facility survey to assess the availability of tuberculosis infection control guidelines, the adequacy of facilities to prevent transmission of tuberculosis and observations of practices to assess the implementation of tuberculosis infection control guidelines. Four focus group discussions were carried out to highlight HCWs' perceptions on tuberculosis infection control guidelines and barriers to its implementation. The observational study showed that none of the clinics had a tuberculosis infection control plan. No clinic was consistently screening patients for cough. Twelve facilities (60%) consistently provided masks to patients who were coughing. Ventilation in the waiting areas was assessed to be adequate in 60% of the clinics while four clinics (20%) possessed N-95 respirators. Findings from the focus group discussions showed weak managerial support, poor funding, under-staffing, lack of space and not wanting to be seen as stigmatizing against tuberculosis patients as barriers that hindered the implementation of TB infection control measures. Tuberculosis infection control measures were not adequately implemented in health facilities in Ikeja, Nigeria. A multi-pronged approach is required to address the identified barriers to the implementation of tuberculosis infection control guidelines.
Effect of test exercises and mask donning on measured respirator fit.
Crutchfield, C D; Fairbank, E O; Greenstein, S L
1999-12-01
Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.
Electroconvulsive therapy can benefit from controlled hyperventilation using a laryngeal mask.
Haeck, Martina; Gillmann, Benjamin; Janouschek, Hildegard; Grözinger, Michael
2011-11-01
Hypocapnia through hyperventilation is a well-known procedure in electroconvulsive therapy (ECT) to enhance seizure activity. However, it has mostly been applied in an uncontrolled manner. Originally intended for a better management of the supraglottic airway, laryngeal masks are more suited to monitor levels of CO(2) during hyperventilation than face masks and thereby provide for the possibility of controlled hyperventilation (CHV). The impact of CHV was retrospectively studied in 114 consecutive patients; 65 of them had received ECT with CHV and 49 had received ECT with uncontrolled hyperventilation (UHV) directly prior to the time period when the laryneal mask was introduced to the ECT treatment procedure. The CO(2) level in the CHV group was aimed at 30 mmHg or below. CHV considerably enhanced the seizure activity leading to changes in clinically determined parameters of the treatment course: the necessity for increasing the electric charge, for re-stimulations (trend) and for bilateral stimulations was lower in the CHV group as compared to the UHV group. The improvement in the Global Assessment of Functioning Scores was not different in both groups. CHV was associated with a higher amount of prolonged seizures, with a reduced number of delirious symptoms after treatments and an attenuating effect on heart rate. Concluding, CHV can help to maintain the applied electric charge low without worsening the clinical outcome. Therefore, it is a helpful technical improvement. However, it should be used carefully with regard to prolonged seizures.
Yeung, Joyce; Chilwan, Mehboob; Field, Richard; Davies, Robin; Gao, Fang; Perkins, Gavin D
2014-07-01
Minimising interruptions in chest compressions is associated with improved survival from cardiac arrest. Current in-hospital guidelines recommend continuous chest compressions after the airway is secured on the premise that this will reduce no flow time. The aim of this study was to determine the effect of advanced airway use on the no flow ratio and other measures of CPR quality. Consecutive adult patients who sustained an in-hospital cardiac arrest were enrolled in this prospective observational study. The quality of CPR was measured using the Q-CPR device (Phillips, UK) before and after an advanced airway device (endotracheal tube [ET] or laryngeal mask airway [LMA]) was inserted. Patients receiving only bag-mask ventilation were used as the control cohort. The primary outcome was no flow ratio (NFR). Secondary outcomes were chest compression rate, depth, compressions too shallow, compressions with leaning, ventilation rate, inflation time, change in impedance and time required to successfully insert airway device. One hundred patients were enrolled in the study (2008-2011). Endotracheal tube and LMA placement took similar durations (median 15.8 s (IQR 6.8-19.4) vs. LMA median 8.0s (IQR 5.5-15.9), p=0.1). The use of an advanced airway was associated with improved no flow ratios (endotracheal tube placement (n=50) improved NFR from baseline median 0.24 IQR 0.17-0.40) to 0.15 to (IQR 0.09-0.28), p=0.012; LMA (n=25) from median 0.28 (IQR 0.23-0.40) to 0.13 (IQR 0.11- 0.19), p=0.0001). There was no change in NFR in patients managed solely with bag valve mask (BVM) (n=25) (median 0.29 (IQR 0.18-0.59) vs. median 0.26 (IQR 0.12-0.37), p=0.888). There was no significant difference in time taken to successfully insert the airway device between the two groups. The use of an advanced airway (ETT or LMA) during in-hospital cardiac arrest was associated with improved no flow ratio. Further studies are required to determine the effect of airway devices on overall patient outcomes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Nguyen, Hoang-Duy; Nguyen, Hieu Pham Trung; Lee, Jae-jin; Mho, Sun-Il
2012-12-01
We report on the achievement of the enhanced cathodoluminescence (CL) from InGaN/GaN light-emitting diodes (LEDs) by using roughening surface. Nanoporous anodic aluminum oxide (AAO) mask was utilized to form nano-hole arrays on the surface of InGaN/GaN LEDs. AAO membranes with ordered hexagonal structures were fabricated from aluminum foils by a two-step anodization method. The average pore densities of ˜1.0 × 1010 cm-2 and 3.0 × 1010 cm-2 were fabricated with the constant anodization voltages of 25 and 40 V, respectively. Anodic porous alumina film with a thickness of ˜600 nm has been used as a mask for the induced couple plasma etching process to fabricate nano-hole arrays on the LED surface. Diameter and depth of nano-holes can be controlled by varying the etching duration and/or the diameter of AAO membranes. Due to the reduction of total internal reflection obtained in the patterned samples, we have observed that the cathodoluminescence intensity of LEDs with nanoporous structures is increased up to eight times compared to that of samples without using nanoporous structure.
Shi, Mi; Larrondo, Luis F; Loros, Jennifer J; Dunlap, Jay C
2007-12-11
In Neurospora, metabolic oscillators coexist with the circadian transcriptional/translational feedback loop governed by the FRQ (Frequency) and WC (White Collar) proteins. One of these, a choline deficiency oscillator (CDO) observed in chol-1 mutants grown under choline starvation, drives an uncompensated long-period developmental cycle ( approximately 60-120 h). To assess possible contributions of this metabolic oscillator to the circadian system, molecular and physiological rhythms were followed in liquid culture under choline starvation, but these only confirmed that an oscillator with a normal circadian period length can run under choline starvation. This finding suggested that long-period developmental cycles elicited by nutritional stress could be masking output from the circadian system, although a caveat was that the CDO sometimes requires several days to become consolidated. To circumvent this and observe both oscillators simultaneously, we used an assay using a codon-optimized luciferase to follow the circadian oscillator. Under conditions where the long-period, uncompensated, CDO-driven developmental rhythm was expressed for weeks in growth tubes, the luciferase rhythm in the same cultures continued in a typical compensated manner with a circadian period length dependent on the allelic state of frq. Periodograms revealed no influence of the CDO on the circadian oscillator. Instead, the CDO appears as a cryptic metabolic oscillator that can, under appropriate conditions, assume control of growth and development, thereby masking output from the circadian system. frq-driven luciferase as a reporter of the circadian oscillator may in this way provide a means for assessing prospective role(s) of metabolic and/or ancillary oscillators within cellular circadian systems.
Chughtai, Abrar Ahmad; MacIntyre, C Raina; Ashraf, Muhammad Orooj; Zheng, Yang; Yang, Peng; Wang, Quanyi; Dung, Tham Chi; Hien, Nguyen Tran; Seale, Holly
2015-10-01
A cross-sectional survey was conducted in 89 secondary- and tertiary-level hospitals in 3 countries, and samples of masks and respirators were also collected and examined. Results showed varied practices around the use of masks and respirators, which are probably influenced by the available resources and local recommendations. Nonstandardized practices are common in low-resource settings, which may be placing health care workers at risk. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
The complete mitochondrial genome of the masked palm civet (Paguma larvata, Mammalia, Carnivora).
Zhang, Dan; Xu, Liwen; Bu, Hongliang; Wang, Di; Xu, Chongren; Wang, Rongjiang
2016-09-01
The complete mitochondrial genome of the masked palm civet (Paguma larvata, Mammalia, Carnivora) is a circular molecule of 16 710 bp in length, containing 22 transfer RNA genes, 13 protein-coding genes, two ribosomal RNA genes, and a control region. The features of the mitochondrial genome of the masked palm civet are similar to the other mammals. The phylogenetic analysis shows that all species from the family Viverridae cluster together, in which P. larvata exhibits the closest relationship with Genetta servalina.
Single closed contact for 0.18-micron photolithography process
NASA Astrophysics Data System (ADS)
Cheung, Cristina; Phan, Khoi A.; Chiu, Robert J.
2000-06-01
With the rapid advances of deep submicron semiconductor technology, identifying defects is converted into a challenge for different modules in the fabrication of chips. Yield engineers often do bitmap on a memory circuit array (SRAM) to identify the failure bits. This is followed by a wafer stripback to look for visual defects at each deprocessed layer for feedback to the Fab. However, to identify the root cause of a problem, Fab engineers must be able to detect similar defects either on the product wafers in process or some short loop test wafers. In the photolithography process, we recognize that the detection of defects is becoming as important as satisfying the critical dimension (CD) of the device. For a multi-level metallization chemically mechanical polish backend process, it is very difficult to detect missing contacts or via at the masking steps due to metal grain roughness, film color variation and/or previous layer defects. Often, photolithography engineer must depend on Photo Cell Monitor (PCM) and short loop experiments for controlling baseline defects and improvement. In this paper, we discuss the findings on the Poly mask PCM and the Contact mask PCM. We present the comparison between the Poly mask and the Contact mask of the I-line Phase Shifted Via mask and DUV mask process for a 0.18 micron process technology. The correlation and the different type of defects between the Contact PCM and the Poly Mask are discussed. The Contact PCM was found to be more sensitive and correlated to contact failure at sort yield better. We also dedicate to study the root cause of a single closed contact hole in the Contact mask short loop experiment for a 0.18 micron process technology. A single closed contact defect was often caused by the developer process, such as bubbles in the line, resist residue left behind, and the rinse mechanism. We also found surfactant solution helps to improve the surface tension of the wafer for the developer process and this prevents/eliminates a single closed contact hole defects. The applications and effects of using different substrates like SiON, different thicknesses of Oxides, and Poly in the Contact Photo Mask is shown. Finally, some defect troubleshooting techniques and the root cause analysis are also discussed.
The color masking ability of a zirconia ceramic on the substrates with different values.
Tabatabaian, Farhad; Javadi Sharif, Mahdiye; Massoumi, Farhood; Namdari, Mahshid
2017-01-01
Background. The color masking ability of a restoration plays a significant role in coveringa discolored substructure; however, this optical property of zirconia ceramics has not been clearly determined yet. The aim of this in vitro study was to evaluate the color masking ability of a zirconia ceramic on substrates with different values. Methods. Ten zirconia disk specimens,0.5 mm in thickness and 10 mm in diameter, were fabricated by a CAD/CAM system. Four substrates with different values were prepared, including: white (control), light grey, dark grey, and black. The disk specimens were placed over the substratesfor spectrophotometric measurements. A spectrophotometer measured the L * , a * , and b * color attributes of the specimens. Additionally, ΔE values were calculated to determine the color differences between each group and the control,and were then compared with the perceptional threshold of ΔE=2.6. Repeated-measures ANOVA, Bonferroni, and one-sample t-test were used to analyze data. All the tests were carried out at 0.05 level of significance. Results. The means and standard deviations of ΔE values for the three groups of light grey, dark grey and black were 9.94±2.11, 10.40±2.09, and 13.34±1.77 units, respectively.Significant differences were detected between the groups in the ΔE values (P<0.0001).The ΔE values in all the groups were more than the predetermined perceptional threshold(ΔE>2.6) (P<0.0001). Conclusion. Within the limitations of this study, it was concluded that the tested zirconia ceramic did not exhibit sufficient color masking ability to hide the grey and black substrates.
Masked Priming Effects in Aphasia: Evidence for Altered Automatic Spreading Activation
Silkes, JoAnn P.; Rogers, Margaret A.
2015-01-01
Purpose Previous research has suggested that impairments of automatic spreading activation may underlie some aphasic language deficits. This study further investigated the status of automatic spreading activation in individuals with aphasia as compared with typical adults. Method Participants were 21 individuals with aphasia (12 fluent, 9 non-fluent) and 31 typical adults. Reaction time data were collected on a lexical decision task with masked repetition primes, assessed at 11 different interstimulus intervals (ISIs). Masked primes were used to assess automatic spreading activation without the confound of conscious processing. The various ISIs were used to assess the time to onset, and duration, of priming effects. Results The control group showed maximal priming in the 200 ms ISI condition, with significant priming at a range of ISIs surrounding that peak. Participants with both fluent and non-fluent aphasia showed maximal priming effects in the 250 ms ISI condition, and primed across a smaller range of ISIs than the control group. Conclusions Results suggest that individuals with aphasia have slowed automatic spreading activation, and impaired maintenance of activation over time, regardless of fluency classification. These findings have implications for understanding aphasic language impairment and for development of aphasia treatments designed directly address automatic language processes. PMID:22411281
Masked priming effects in aphasia: evidence of altered automatic spreading activation.
Silkes, JoAnn P; Rogers, Margaret A
2012-12-01
Previous research has suggested that impairments of automatic spreading activation may underlie some aphasic language deficits. The current study further investigated the status of automatic spreading activation in individuals with aphasia as compared with typical adults. Participants were 21 individuals with aphasia (12 fluent, 9 nonfluent) and 31 typical adults. Reaction time data were collected on a lexical decision task with masked repetition primes, assessed at 11 different interstimulus intervals (ISIs). Masked primes were used to assess automatic spreading activation without the confound of conscious processing. The various ISIs were used to assess the time to onset and duration of priming effects. The control group showed maximal priming in the 200-ms ISI condition, with significant priming at a range of ISIs surrounding that peak. Participants with both fluent and nonfluent aphasia showed maximal priming effects in the 250-ms ISI condition and primed across a smaller range of ISIs than did the control group. Results suggest that individuals with aphasia have slowed automatic spreading activation and impaired maintenance of activation over time, regardless of fluency classification. These findings have implications for understanding aphasic language impairment and for development of aphasia treatments designed to directly address automatic language processes.
Peacock, James; Diaz, Keith M.; Viera, Anthony J.; Schwartz, Joseph E.; Shimbo, Daichi
2014-01-01
‘Masked hypertension’ is defined as having non-elevated clinic blood pressure (BP) with elevated out-of-clinic average BP, typically determined by ambulatory BP monitoring. Approximately 15–30% of adults with non-elevated clinic BP have masked hypertension. Masked hypertension is associated with increased risks of cardiovascular morbidity and mortality compared to sustained normotension (non-elevated clinic and ambulatory BP), which is similar to or approaching the risk associated with sustained hypertension (elevated clinic and ambulatory BP). The confluence of increased cardiovascular risk and a failure to be diagnosed by the conventional approach of clinic BP measurement makes masked hypertension a significant public health concern. However, many important questions remain. First, the definition of masked hypertension varies across studies. Further, the best approach in the clinical setting to exclude masked hypertension also remains unknown. It is unclear whether home BP monitoring is an adequate substitute for ambulatory BP monitoring in identifying masked hypertension. Few studies have examined the mechanistic pathways that may explain masked hypertension. Finally, scarce data are available on the best approach to treating individuals with masked hypertension. Herein, we review the current literature on masked hypertension including definition, prevalence, clinical implications, special patient populations, correlates, issues related to diagnosis, treatment, and areas for future research. PMID:24573133
Complex Pupil Masks for Aberrated Imaging of Closely Spaced Objects
NASA Astrophysics Data System (ADS)
Reddy, A. N. K.; Sagar, D. K.; Khonina, S. N.
2017-12-01
Current approach demonstrates the suppression of optical side-lobes and the contraction of the main lobe in the composite image of two object points of the optical system under the influence of defocusing effect when an asymmetric phase edges are imposed over the apodized circular aperture. The resolution of two point sources having different intensity ratio is discussed in terms of the modified Sparrow criterion, functions of the degree of coherence of the illumination, the intensity difference and the degree of asymmetric phase masking. Here we have introduced and explored the effects of focus aberration (defect-of-focus) on the two-point resolution of the optical systems. Results on the aberrated composite image of closely spaced objects with amplitude mask and asymmetric phase masks forms a significant contribution in astronomical and microscopic observations.
EUV phase-shifting masks and aberration monitors
NASA Astrophysics Data System (ADS)
Deng, Yunfei; Neureuther, Andrew R.
2002-07-01
Rigorous electromagnetic simulation with TEMPEST is used to examine the use of phase-shifting masks in EUV lithography. The effects of oblique incident illumination and mask patterning by ion-mixing of multilayers are analyzed. Oblique incident illumination causes streamers at absorber edges and causes position shifting in aerial images. The diffraction waves between ion-mixed and pristine multilayers are observed. The phase-shifting caused by stepped substrates is simulated and images show that it succeeds in creation of phase-shifting effects. The diffraction process at the phase boundary is also analyzed. As an example of EUV phase-shifting masks, a coma pattern and probe based aberration monitor is simulated and aerial images are formed under different levels of coma aberration. The probe signal rises quickly as coma increases as designed.
Micromachined microwave signal control device and method for making same
Forman, Michael A [San Francisco, CA
2008-09-02
A method for fabricating a signal controller, e.g., a filter or a switch, for a coplanar waveguide during the LIGA fabrication process of the waveguide. Both patterns for the waveguide and patterns for the signal controllers are created on a mask. Radiation travels through the mask and reaches a photoresist layer on a substrate. The irradiated portions are removed and channels are formed on the substrate. A metal is filled into the channels to form the conductors of the waveguide and the signal controllers. Micromachined quasi-lumped elements are used alone or together as filters. The switch includes a comb drive, a spring, a metal plunger, and anchors.
Method for making a micromachined microwave signal control device
Forman, Michael A [Mountain House, CA
2011-02-15
A method for fabricating a signal controller, e.g., a filter or a switch, for a coplanar waveguide during the LIGA fabrication process of the waveguide. Both patterns for the waveguide and patterns for the signal controllers are created on a mask. Radiation travels through the mask and reaches a photoresist layer on a substrate. The irradiated portions are removed and channels are formed on the substrate. A metal is filled into the channels to form the conductors of the waveguide and the signal controllers. Micromachined quasi-lumped elements are used alone or together as filters. The switch includes a comb drive, a spring, a metal plunger, and anchors.
Bettinzoli, Michela; Taranto-Montemurro, Luigi; Messineo, Ludovico; Corda, Luciano; Redolfi, Stefania; Ferliga, Mauro; Tantucci, Claudio
2014-12-01
The purpose of this study was to compare the therapeutic pressure determined by an automated CPAP device (AutoCPAP) during the titration period, between nasal and oronasal mask and the residual apnea-hypopnea index (AHI) on a subsequent poligraphy performed with the established therapeutic CPAP. As a retrospective study, 109 subjects with moderate and severe obstructive sleep apnea-hypopnea (apnea-hypopnea index≥15 events/h) were studied. CPAP titration was performed using an auto-titrating device. There was significant difference in the mean pressure delivered with autoCPAP between the group of patients using the nasal mask (mean 10.0 cmH2O±2.0 SD) and the group which used the oronasal mask (mean 11.2 cmH2O±2.1) (p<0.05). Residual apneas were lower when using a nasal mask: average AHI of 2.6±2.5 compared to 4.5±4.0 using an oronasal mask (p<0.05). On multivariate analysis, the only independent predictor of the level of therapeutic pressure of CPAP was the type of mask used (r=0.245, p 0.008). Therapeutic CPAP level for OSAH is higher when administered via oronasal mask, leaving more residual events. These findings suggest that nasal mask should be the first choice for OSAH treatment.
Temporal masking of multidimensional tactual stimuli
NASA Astrophysics Data System (ADS)
Tan, Hong Z.; Reed, Charlotte M.; Delhorne, Lorraine A.; Durlach, Nathaniel I.; Wan, Natasha
2003-12-01
Experiments were performed to examine the temporal masking properties of multidimensional tactual stimulation patterns delivered to the left index finger. The stimuli consisted of fixed-frequency sinusoidal motions in the kinesthetic (2 or 4 Hz), midfrequency (30 Hz), and cutaneous (300 Hz) frequency ranges. Seven stimuli composed of one, two, or three spectral components were constructed at each of two signal durations (125 or 250 ms). Subjects identified target signals under three different masking paradigms: forward masking, backward masking, and sandwiched masking (in which the target is presented between two maskers). Target identification was studied as a function of interstimulus interval (ISI) in the range 0 to 640 ms. For both signal durations, percent-correct scores increased with ISI for each of the three masking paradigms. Scores with forward and backward masking were similar and significantly higher than scores obtained with sandwiched masking. Analyses of error trials revealed that subjects showed a tendency to respond, more often than chance, with the masker, the composite of the masker and target, or the combination of the target and a component of the masker. The current results are compared to those obtained in previous studies of tactual recognition masking with brief cutaneous spatial patterns. The results are also discussed in terms of estimates of information transfer (IT) and IT rate, are compared to previous studies with multidimensional tactual signals, and are related to research on the development of tactual aids for the deaf.
Meese, Tim S; Holmes, David J
2010-10-01
Most contemporary models of spatial vision include a cross-oriented route to suppression (masking from a broadly tuned inhibitory pool), which is most potent at low spatial and high temporal frequencies (T. S. Meese & D. J. Holmes, 2007). The influence of this pathway can elevate orientation-masking functions without exciting the target mechanism, and because early psychophysical estimates of filter bandwidth did not accommodate this, it is likely that they have been overestimated for this corner of stimulus space. Here we show that a transient 40% contrast mask causes substantial binocular threshold elevation for a transient vertical target, and this declines from a mask orientation of 0° to about 40° (indicating tuning), and then more gently to 90°, where it remains at a factor of ∼4. We also confirm that cross-orientation masking is diminished or abolished at high spatial frequencies and for sustained temporal modulation. We fitted a simple model of pedestal masking and cross-orientation suppression (XOS) to our data and those of G. C. Phillips and H. R. Wilson (1984) and found the dependency of orientation bandwidth on spatial frequency to be much less than previously supposed. An extension of our linear spatial pooling model of contrast gain control and dilution masking (T. S. Meese & R. J. Summers, 2007) is also shown to be consistent with our results using filter bandwidths of ±20°. Both models include tightly and broadly tuned components of divisive suppression. More generally, because XOS and/or dilution masking can affect the shape of orientation-masking curves, we caution that variations in bandwidth estimates might reflect variations in processes that have nothing to do with filter bandwidth.