Sample records for obstruction beacons

  1. Antarctic field tests of SARSAT personal locater beacons

    NASA Technical Reports Server (NTRS)

    Bindschadler, Robert

    1987-01-01

    Field tests of SARSAT personal locater beacons were conducted in the Antarctic to assess the viability of using these beacons to increase the safety of Antarctic field parties. Data were collected on the extent to which dry or wet snow, melting conditions, crevasse walls and snow bridges affected the ability of the SARSAT satellite to calculate an accurate position of the beacon. Average response time between beacon turn on and alert reception in McMurdo was between 4 and 5 hours for these tests. It is concluded that the SARSAT system is viable for Antarctic operations and it is recommended that it be implemented for future field operations. Because of obstruction of line-of-sight between beacon and satellite degrades the accuracy of the location calculation (particularly in wet snow), it is further recommended that field parties have sufficient numbers of beacons to insure that in an emergency, one will be able to operate from the surface.

  2. Evaluation of Pedestrian Hybrid Beacons and Rapid Flashing Beacons

    DOT National Transportation Integrated Search

    2016-07-01

    Two pedestrian treatments receiving national attention are the rectangular rapid-flashing beacon (RRFB) and the pedestrian hybrid beacon (PHB). These devices have unique characteristics that produce improved vehicle stopping and yielding to crossing ...

  3. Tester for Distress Beacons

    NASA Technical Reports Server (NTRS)

    Wade, W. R.

    1986-01-01

    Distress beacons on aircraft and boats checked for proper operation with aid of onboard monitor. Monitor mounted in aircraft cockpit or at wheel of boat. Connected to beacon electronics by cable. Monitor used with interface circuitry in beacon, which acts as buffer so that operation of beacon is not adversely affected if monitor is removed or if connecting cable is accidentally short circuited.

  4. Digital Controller For Emergency Beacon

    NASA Technical Reports Server (NTRS)

    Ivancic, William D.

    1990-01-01

    Prototype digital controller intended for use in 406-MHz emergency beacon. Undergoing development according to international specifications, 406-MHz emergency beacon system includes satellites providing worldwide monitoring of beacons, with Doppler tracking to locate each beacon within 5 km. Controller turns beacon on and off and generates binary codes identifying source (e.g., ship, aircraft, person, or vehicle on land). Codes transmitted by phase modulation. Knowing code, monitor attempts to communicate with user, monitor uses code information to dispatch rescue team appropriate to type and locations of carrier.

  5. A digital beacon receiver

    NASA Technical Reports Server (NTRS)

    Ransome, Peter D.

    1988-01-01

    A digital satellite beacon receiver is described which provides measurement information down to a carrier/noise density ratio approximately 15 dB below that required by a conventional (phase locked loop) design. When the beacon signal fades, accuracy degrades gracefully, and is restored immediately (without hysteresis) on signal recovery, even if the signal has faded into the noise. Benefits of the digital processing approach used include the minimization of operator adjustments, stability of the phase measuring circuits with time, repeatability between units, and compatibility with equipment not specifically designed for propagation measuring. The receiver has been developed for the European Olympus satellite which has continuous wave (CW) beacons at 12.5 and 29.7 GHz, and a switched polarization beacon at 19.8 GHz approximately, but the system can be reconfigured for CW and polarization-switched beacons at other frequencies.

  6. Molecular beacon sequence design algorithm.

    PubMed

    Monroe, W Todd; Haselton, Frederick R

    2003-01-01

    A method based on Web-based tools is presented to design optimally functioning molecular beacons. Molecular beacons, fluorogenic hybridization probes, are a powerful tool for the rapid and specific detection of a particular nucleic acid sequence. However, their synthesis costs can be considerable. Since molecular beacon performance is based on its sequence, it is imperative to rationally design an optimal sequence before synthesis. The algorithm presented here uses simple Microsoft Excel formulas and macros to rank candidate sequences. This analysis is carried out using mfold structural predictions along with other free Web-based tools. For smaller laboratories where molecular beacons are not the focus of research, the public domain algorithm described here may be usefully employed to aid in molecular beacon design.

  7. Privacy Risks from Genomic Data-Sharing Beacons

    PubMed Central

    Shringarpure, Suyash S.; Bustamante, Carlos D.

    2015-01-01

    The human genetics community needs robust protocols that enable secure sharing of genomic data from participants in genetic research. Beacons are web servers that answer allele-presence queries—such as “Do you have a genome that has a specific nucleotide (e.g., A) at a specific genomic position (e.g., position 11,272 on chromosome 1)?”—with either “yes” or “no.” Here, we show that individuals in a beacon are susceptible to re-identification even if the only data shared include presence or absence information about alleles in a beacon. Specifically, we propose a likelihood-ratio test of whether a given individual is present in a given genetic beacon. Our test is not dependent on allele frequencies and is the most powerful test for a specified false-positive rate. Through simulations, we showed that in a beacon with 1,000 individuals, re-identification is possible with just 5,000 queries. Relatives can also be identified in the beacon. Re-identification is possible even in the presence of sequencing errors and variant-calling differences. In a beacon constructed with 65 European individuals from the 1000 Genomes Project, we demonstrated that it is possible to detect membership in the beacon with just 250 SNPs. With just 1,000 SNP queries, we were able to detect the presence of an individual genome from the Personal Genome Project in an existing beacon. Our results show that beacons can disclose membership and implied phenotypic information about participants and do not protect privacy a priori. We discuss risk mitigation through policies and standards such as not allowing anonymous pings of genetic beacons and requiring minimum beacon sizes. PMID:26522470

  8. Underwater Acoustic Beacon Location System

    DTIC Science & Technology

    2016-12-23

    300087 1 of 31 UNDERWATER ACOUSTIC BEACON LOCATION SYSTEM [0001] The present application claims the benefit of United States Provisional...Application Serial Number 62/297,179 filed on February 19, 2016 by the inventor, Steven E. Crocker and entitled “ Underwater Acoustic Beacon...search for and can locate an underwater location beacon. Attorney Docket No. 300087 2 of 31 (2) Description of the Prior Art [0005

  9. Privacy Risks from Genomic Data-Sharing Beacons.

    PubMed

    Shringarpure, Suyash S; Bustamante, Carlos D

    2015-11-05

    The human genetics community needs robust protocols that enable secure sharing of genomic data from participants in genetic research. Beacons are web servers that answer allele-presence queries--such as "Do you have a genome that has a specific nucleotide (e.g., A) at a specific genomic position (e.g., position 11,272 on chromosome 1)?"--with either "yes" or "no." Here, we show that individuals in a beacon are susceptible to re-identification even if the only data shared include presence or absence information about alleles in a beacon. Specifically, we propose a likelihood-ratio test of whether a given individual is present in a given genetic beacon. Our test is not dependent on allele frequencies and is the most powerful test for a specified false-positive rate. Through simulations, we showed that in a beacon with 1,000 individuals, re-identification is possible with just 5,000 queries. Relatives can also be identified in the beacon. Re-identification is possible even in the presence of sequencing errors and variant-calling differences. In a beacon constructed with 65 European individuals from the 1000 Genomes Project, we demonstrated that it is possible to detect membership in the beacon with just 250 SNPs. With just 1,000 SNP queries, we were able to detect the presence of an individual genome from the Personal Genome Project in an existing beacon. Our results show that beacons can disclose membership and implied phenotypic information about participants and do not protect privacy a priori. We discuss risk mitigation through policies and standards such as not allowing anonymous pings of genetic beacons and requiring minimum beacon sizes. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Searching for Cost-Optimized Interstellar Beacons

    NASA Astrophysics Data System (ADS)

    Benford, Gregory; Benford, James; Benford, Dominic

    2010-06-01

    What would SETI beacon transmitters be like if built by civilizations that had a variety of motives but cared about cost? In a companion paper, we presented how, for fixed power density in the far field, a cost-optimum interstellar beacon system could be built. Here, we consider how we should search for a beacon if it were produced by a civilization similar to ours. High-power transmitters could be built for a wide variety of motives other than the need for two-way communication; this would include beacons built to be seen over thousands of light-years. Extraterrestrial beacon builders would likely have to contend with economic pressures just as their terrestrial counterparts do. Cost, spectral lines near 1 GHz, and interstellar scintillation favor radiating frequencies substantially above the classic "water hole." Therefore, the transmission strategy for a distant, cost-conscious beacon would be a rapid scan of the galactic plane with the intent to cover the angular space. Such pulses would be infrequent events for the receiver. Such beacons built by distant, advanced, wealthy societies would have very different characteristics from what SETI researchers seek. Future searches should pay special attention to areas along the galactic disk where SETI searches have seen coherent signals that have not recurred on the limited listening time intervals we have used. We will need to wait for recurring events that may arriarrive in intermittent bursts. Several new SETI search strategies have emerged from these ideas. We propose a new test for beacons that is based on the Life Plane hypotheses.

  11. Searching for Cost-Optimized Interstellar Beacons

    NASA Technical Reports Server (NTRS)

    Benford, Gregory; Benford, James; Benford, Dominic

    2010-01-01

    What would SETI beacon transmitters be like if built by civilizations that had a variety of motives but cared about cost? In a companion paper, we presented how, for fixed power density in the far field, a cost-optimum interstellar beacon system could be built. Here, we consider how we should search for a beacon if it were produced by a civilization similar to ours. High-power transmitters could be built for a wide variety of motives other than the need for two-way communication, this would include beacons built to be seen over thousands of light-years. Extraterrestrial beacon builders would likely have to contend with economic pressures just as their terrestrial counterparts do. Cost, spectral lines near 1GHz, and interstellar scintillation favor radiating frequencies substantially above the classic "water hole." Therefore, the transmission strategy for a distant, cost-conscious beacon would be a rapid scan of the galactic plane with the intent to cover the angular space. Such pulses would be infrequent events for the receiver. Such beacons built by distant, advanced, wealthy societies would have very different characteristics from what SETI researchers seek. Future searches should pay special attention to areas along the galactic disk where SETI searches have seen coherent signals that have not recurred on the limited listening time intervals we have used. We will need to wait for recurring events that may arrive in intermittent bursts. Several new SETI search strategies have emerged from these ideas. We propose a new test for beacons that is based on the Life Plane hypotheses.

  12. Searching for cost-optimized interstellar beacons.

    PubMed

    Benford, Gregory; Benford, James; Benford, Dominic

    2010-06-01

    What would SETI beacon transmitters be like if built by civilizations that had a variety of motives but cared about cost? In a companion paper, we presented how, for fixed power density in the far field, a cost-optimum interstellar beacon system could be built. Here, we consider how we should search for a beacon if it were produced by a civilization similar to ours. High-power transmitters could be built for a wide variety of motives other than the need for two-way communication; this would include beacons built to be seen over thousands of light-years. Extraterrestrial beacon builders would likely have to contend with economic pressures just as their terrestrial counterparts do. Cost, spectral lines near 1 GHz, and interstellar scintillation favor radiating frequencies substantially above the classic "water hole." Therefore, the transmission strategy for a distant, cost-conscious beacon would be a rapid scan of the galactic plane with the intent to cover the angular space. Such pulses would be infrequent events for the receiver. Such beacons built by distant, advanced, wealthy societies would have very different characteristics from what SETI researchers seek. Future searches should pay special attention to areas along the galactic disk where SETI searches have seen coherent signals that have not recurred on the limited listening time intervals we have used. We will need to wait for recurring events that may arrive in intermittent bursts. Several new SETI search strategies have emerged from these ideas. We propose a new test for beacons that is based on the Life Plane hypotheses.

  13. Olympus beacon receiver

    NASA Technical Reports Server (NTRS)

    Ostergaard, Jens

    1988-01-01

    A medium-size Beacon Receiving System for reception and processing of the B1 (20 GHz) and B2 (30 GHz) beacons from Olympus has been developed. Integration of B1 and B2 receiving equipment into one system using one antenna and a common computer for control and data processing provides the advantages of a compact configuration and synchronization of the two receiver chains. Range for co-polar signal attenuation meaurement is about 30 dB for both beacons, increasing to 40 dB for B2 if the receivers are synchronized to B1. The accuracy is better than 0.5 dB. Cross-polarization discriminations of the order of 10 to 30 dB may be determined with an accuracy of 1 to 2 dB. A number of radiometers for complementary measurements of atmospheric attenuation of 13 to 30 GHz has also been constructed. A small multi-frequency system for operation around 22 GHz and 31 GHz is presently under development.

  14. 33 CFR 62.23 - Beacons and buoys.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... navigation. The primary components of the U.S. Aids to Navigation System are beacons and buoys. (b) Beacons are aids to navigation structures which are permanently fixed to the earth's surface. They range from... UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.23 Beacons and buoys. (a...

  15. 33 CFR 62.23 - Beacons and buoys.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... navigation. The primary components of the U.S. Aids to Navigation System are beacons and buoys. (b) Beacons are aids to navigation structures which are permanently fixed to the earth's surface. They range from... UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.23 Beacons and buoys. (a...

  16. 33 CFR 62.23 - Beacons and buoys.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... navigation. The primary components of the U.S. Aids to Navigation System are beacons and buoys. (b) Beacons are aids to navigation structures which are permanently fixed to the earth's surface. They range from... UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.23 Beacons and buoys. (a...

  17. 33 CFR 62.23 - Beacons and buoys.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... navigation. The primary components of the U.S. Aids to Navigation System are beacons and buoys. (b) Beacons are aids to navigation structures which are permanently fixed to the earth's surface. They range from... UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.23 Beacons and buoys. (a...

  18. 33 CFR 62.23 - Beacons and buoys.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... navigation. The primary components of the U.S. Aids to Navigation System are beacons and buoys. (b) Beacons are aids to navigation structures which are permanently fixed to the earth's surface. They range from... UNITED STATES AIDS TO NAVIGATION SYSTEM The U.S. Aids to Navigation System § 62.23 Beacons and buoys. (a...

  19. Determining Locations by Use of Networks of Passive Beacons

    NASA Technical Reports Server (NTRS)

    Okino, Clayton; Gray, Andrew; Jennings, Esther

    2009-01-01

    Networks of passive radio beacons spanning moderate-sized terrain areas have been proposed to aid navigation of small robotic aircraft that would be used to explore Saturn s moon Titan. Such networks could also be used on Earth to aid navigation of robotic aircraft, land vehicles, or vessels engaged in exploration or reconnaissance in situations or locations (e.g., underwater locations) in which Global Positioning System (GPS) signals are unreliable or unavailable. Prior to use, it would be necessary to pre-position the beacons at known locations that would be determined by use of one or more precise independent global navigation system(s). Thereafter, while navigating over the area spanned by a given network of passive beacons, an exploratory robot would use the beacons to determine its position precisely relative to the known beacon positions (see figure). If it were necessary for the robot to explore multiple, separated terrain areas spanned by different networks of beacons, the robot could use a long-haul, relatively coarse global navigation system for the lower-precision position determination needed during transit between such areas. The proposed method of precise determination of position of an exploratory robot relative to the positions of passive radio beacons is based partly on the principles of radar and partly on the principles of radio-frequency identification (RFID) tags. The robot would transmit radar-like signals that would be modified and reflected by the passive beacons. The distance to each beacon would be determined from the roundtrip propagation time and/or round-trip phase shift of the signal returning from that beacon. Signals returned from different beacons could be distinguished by means of their RFID characteristics. Alternatively or in addition, the antenna of each beacon could be designed to radiate in a unique pattern that could be identified by the navigation system. Also, alternatively or in addition, sets of identical beacons could

  20. 14 CFR 171.269 - Marker beacon performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Marker beacon performance requirements. 171.269 Section 171.269 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Landing System (ISMLS) § 171.269 Marker beacon performance requirements. ISMLS marker beacon equipment...

  1. Messaging with Cost-Optimized Interstellar Beacons

    NASA Technical Reports Server (NTRS)

    Benford, James; Benford, Gregory; Benford, Dominic

    2010-01-01

    On Earth, how would we build galactic-scale beacons to attract the attention of extraterrestrials, as some have suggested we should do? From the point of view of expense to a builder on Earth, experience shows an optimum trade-off. This emerges by minimizing the cost of producing a desired power density at long range, which determines the maximum range of detectability of a transmitted signal. We derive general relations for cost-optimal aperture and power. For linear dependence of capital cost on transmitter power and antenna area, minimum capital cost occurs when the cost is equally divided between antenna gain and radiated power. For nonlinear power-law dependence, a similar simple division occurs. This is validated in cost data for many systems; industry uses this cost optimum as a rule of thumb. Costs of pulsed cost-efficient transmitters are estimated from these relations by using current cost parameters ($/W, $/sq m) as a basis. We show the scaling and give examples of such beacons. Galactic-scale beacons can be built for a few billion dollars with our present technology. Such beacons have narrow "searchlight" beams and short "dwell times" when the beacon would be seen by an alien observer in their sky. More-powerful beacons are more efficient and have economies of scale: cost scales only linearly with range R, not as R(exp 2), so number of stars radiated to increases as the square of cost. On a cost basis, they will likely transmit at higher microwave frequencies, -10 GHz. The natural corridor to broadcast is along the galactic radius or along the local spiral galactic arm we are in. A companion paper asks "If someone like us were to produce a beacon, how should we look for it?"

  2. Evaluation of Skylab earth laser beacon imagery. [spaceborne photography

    NASA Technical Reports Server (NTRS)

    Piech, K. R.; Schott, J. R.

    1975-01-01

    During the Skylab 3 and 4 missions the Skylab spacecraft was illuminated by a low power argon ion and dye laser. The earth laser beacon was studied visually by the astronauts. In addition, they collected 35 mm hand-held color photographs of the beacons. Photographs are shown that were obtained on Skylab 3 and Skylab 4. The imagery collected during the Skylab mission was analyzed to evaluate the utility of beacon lasers as terrestial 'artificial stars' for space navigation. The analyses of the imagery revealed two unusual features of the earth laser beacon: (1) The beacon, even though of a low power (approximately 1 watt), is considerably brighter than any other terrain feature and is readily visible on imagery at a distance in excess of 1500 km (900 miles). (2) Another feature of the beacon is its large size. The typical beacon extends over about 5 resolution areas with a characteristic dimension of about 200 m.

  3. Personal Beacon

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The MicroPLB (personal locator beacon) is a search and rescue satellite-aided tracking (SARSAT) transmitter. When activated it emits a distress signal to a constellation of internationally operated satellites. The endangered person's identity and location anywhere on Earth is automatically forwarded to central monitoring stations around the world. It is accurate to within just a few meters. The user uses the device to download navigation data from a global positioning satellite receiver. After the download is complete, the MicroPLB functions as a self-locating beacon. Also, it is the only PLB to use a safe battery. In the past, other PLB devices have used batteries that have enough volatility to explode with extreme force. It was developed by Microwave Monolithic, Inc. through SBIR funding from Glenn Research Center and Goddard Space Flight Center.

  4. Robot-Beacon Distributed Range-Only SLAM for Resource-Constrained Operation

    PubMed Central

    Torres-González, Arturo; Martínez-de Dios, Jose Ramiro; Ollero, Anibal

    2017-01-01

    This work deals with robot-sensor network cooperation where sensor nodes (beacons) are used as landmarks for Range-Only (RO) Simultaneous Localization and Mapping (SLAM). Most existing RO-SLAM techniques consider beacons as passive devices disregarding the sensing, computational and communication capabilities with which they are actually endowed. SLAM is a resource-demanding task. Besides the technological constraints of the robot and beacons, many applications impose further resource consumption limitations. This paper presents a scalable distributed RO-SLAM scheme for resource-constrained operation. It is capable of exploiting robot-beacon cooperation in order to improve SLAM accuracy while meeting a given resource consumption bound expressed as the maximum number of measurements that are integrated in SLAM per iteration. The proposed scheme combines a Sparse Extended Information Filter (SEIF) SLAM method, in which each beacon gathers and integrates robot-beacon and inter-beacon measurements, and a distributed information-driven measurement allocation tool that dynamically selects the measurements that are integrated in SLAM, balancing uncertainty improvement and resource consumption. The scheme adopts a robot-beacon distributed approach in which each beacon participates in the selection, gathering and integration in SLAM of robot-beacon and inter-beacon measurements, resulting in significant estimation accuracies, resource-consumption efficiency and scalability. It has been integrated in an octorotor Unmanned Aerial System (UAS) and evaluated in 3D SLAM outdoor experiments. The experimental results obtained show its performance and robustness and evidence its advantages over existing methods. PMID:28425946

  5. Robot-Beacon Distributed Range-Only SLAM for Resource-Constrained Operation.

    PubMed

    Torres-González, Arturo; Martínez-de Dios, Jose Ramiro; Ollero, Anibal

    2017-04-20

    This work deals with robot-sensor network cooperation where sensor nodes (beacons) are used as landmarks for Range-Only (RO) Simultaneous Localization and Mapping (SLAM). Most existing RO-SLAM techniques consider beacons as passive devices disregarding the sensing, computational and communication capabilities with which they are actually endowed. SLAM is a resource-demanding task. Besides the technological constraints of the robot and beacons, many applications impose further resource consumption limitations. This paper presents a scalable distributed RO-SLAM scheme for resource-constrained operation. It is capable of exploiting robot-beacon cooperation in order to improve SLAM accuracy while meeting a given resource consumption bound expressed as the maximum number of measurements that are integrated in SLAM per iteration. The proposed scheme combines a Sparse Extended Information Filter (SEIF) SLAM method, in which each beacon gathers and integrates robot-beacon and inter-beacon measurements, and a distributed information-driven measurement allocation tool that dynamically selects the measurements that are integrated in SLAM, balancing uncertainty improvement and resource consumption. The scheme adopts a robot-beacon distributed approach in which each beacon participates in the selection, gathering and integration in SLAM of robot-beacon and inter-beacon measurements, resulting in significant estimation accuracies, resource-consumption efficiency and scalability. It has been integrated in an octorotor Unmanned Aerial System (UAS) and evaluated in 3D SLAM outdoor experiments. The experimental results obtained show its performance and robustness and evidence its advantages over existing methods.

  6. Molecular Beacon-Based MicroRNA Imaging During Neurogenesis.

    PubMed

    Lee, Jonghwan; Kim, Soonhag

    2016-01-01

    The fluorescence monitoring system for examining endogenous microRNA (miRNA) activity in cellular level provides crucial information on not only understanding a critical role of miRNA involving a variety of biological processes, but also evaluating miRNA expression patterns in a noninvasive manner. In this protocol, we report the details of a new procedure for a molecular beacon-based miRNA monitoring system, which includes the illustration scheme for miRNA detection strategy, exogenous miRNA detection, and measurement of endogenous miRNA expression level during neurogenesis. The fluorescence signal of miR-124a beacon quenched by BHQ2 was gradually recovered as increasing concentration of the miR-124a in tube. The functional work of miR-124a beacon was examined in intracellular environment, allowing for the internalization of the miR-124a beacon by lipofectamine, which resulted in activated fluorescent signals of the miR-124a beacon in the HeLa cells after the addition of synthetic miR-124a. The endogenous miR-124a expression level was detected by miR-124a beacon system during neurogenesis, showing brighter fluorescence intensity in cytoplasmic area of P19 cells after induction of neuronal differentiation by retinoic acid. The molecular beacon based-miRNA detection technique could be applicable to the simultaneous visualization of a variety of miRNA expression patterns using different fluorescence dyes. For the study of examining endogenous miRNA expression level using miRNA-beacon system, if cellular differentiation step is already prepared, transfection step of miR-124a beacon into P19 cells, and acquisition of activated fluorescence signal measured by confocal microscope can be conducted approximately within 6 h.

  7. High-visibility infrared beacons for IFF and combat ID

    NASA Astrophysics Data System (ADS)

    Pralle, Martin; Puscasu, Irina; Johnson, Edward; Loges, Peter; Melnyk, James

    2005-05-01

    A new kind of Identification Friend or Foe (IFF) infrared beacon has been demonstrated. The omni-directional beacon consists of a pyramidal array of 1W pulsIR thermal light sources. Operating at a total power of 84W, the beacon can be used to track and identify surface vehicles and personnel with a recognition range of up to 6 miles on the battlefield and in urban environments or the marine boundary layer. Advanced photonic technology enables the beacon to be seen only while using a 3-5 μm or 8-12 μm thermal imaging system. There is no visible or near-IR emission to betray the location of the beacon. The beacon is rugged and will operate from -40 to 50°C ambient temperature, 0-100% relative humidity, 0 - 10,000 ft altitude, and meets MIL-STD 810F and MIL-STD 461E.

  8. A search for optical beacons: implications of null results.

    PubMed

    Blair, David G; Zadnik, Marjan G

    2002-01-01

    Over the past few years a series of searches for interstellar radio beacons have taken place using the Parkes radio telescope. Here we report hitherto unpublished results from a search for optical beacons from 60 solar-type stars using the Perth-Lowell telescope. We discuss the significance of the null results from these searches, all of which were based on the interstellar contact channel hypothesis. While the null results of all searches to date can be explained simply by the nonexistence of electromagnetically communicating life elsewhere in the Milky Way, four other possible explanations that do not preclude its existence are proposed: (1) Extraterrestrial civilizations desiring to make contact through the use of electromagnetic beacons have a very low density in the Milky Way. (2) The interstellar contact channel hypothesis is incorrect, and beacons exist at frequencies that have not yet been searched. (3) The search has been incomplete in terms of sensitivity and/or target directions: Beacons exist, but more sensitive equipment and/or more searching is needed to achieve success. (4) The search has occurred before beacon signals can be expected to have arrived at the Earth, and beacon signals may be expected in the future. Based on consideration of the technology required for extraterrestrial civilizations to identify target planets, we argue that the fourth possibility is likely to be valid and that powerful, easily detectable beacons could be received in coming centuries.

  9. Beacon Beams for Deep Turbulence High Energy Laser Beam Directors

    DTIC Science & Technology

    2012-11-02

    variance and nC is the atmospheric refractive index structure constant. The effect of turbulence on the focused beacon beam on target, TR...complete phase conjugation of the beacon beam is accomplished by employing Brillouin enhanced optical four wave mixing. A beacon beam formed by...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6790--12-9445 Beacon Beams for Deep Turbulence High Energy Laser Beam Directors P

  10. Localization with a mobile beacon in underwater acoustic sensor networks.

    PubMed

    Lee, Sangho; Kim, Kiseon

    2012-01-01

    Localization is one of the most important issues associated with underwater acoustic sensor networks, especially when sensor nodes are randomly deployed. Given that it is difficult to deploy beacon nodes at predetermined locations, localization schemes with a mobile beacon on the sea surface or along the planned path are inherently convenient, accurate, and energy-efficient. In this paper, we propose a new range-free Localization with a Mobile Beacon (LoMoB). The mobile beacon periodically broadcasts a beacon message containing its location. Sensor nodes are individually localized by passively receiving the beacon messages without inter-node communications. For location estimation, a set of potential locations are obtained as candidates for a node's location and then the node's location is determined through the weighted mean of all the potential locations with the weights computed based on residuals.

  11. Localization with a Mobile Beacon in Underwater Acoustic Sensor Networks

    PubMed Central

    Lee, Sangho; Kim, Kiseon

    2012-01-01

    Localization is one of the most important issues associated with underwater acoustic sensor networks, especially when sensor nodes are randomly deployed. Given that it is difficult to deploy beacon nodes at predetermined locations, localization schemes with a mobile beacon on the sea surface or along the planned path are inherently convenient, accurate, and energy-efficient. In this paper, we propose a new range-free Localization with a Mobile Beacon (LoMoB). The mobile beacon periodically broadcasts a beacon message containing its location. Sensor nodes are individually localized by passively receiving the beacon messages without inter-node communications. For location estimation, a set of potential locations are obtained as candidates for a node's location and then the node's location is determined through the weighted mean of all the potential locations with the weights computed based on residuals. PMID:22778597

  12. Multiple beacons for supporting lunar landing navigation

    NASA Astrophysics Data System (ADS)

    Theil, Stephan; Bora, Leonardo

    2018-02-01

    The exploration and potential future exploitation of solar system bodies requires technologies for precise and safe landings. Current navigation systems for landing probes are relying on a combination of inertial and optical sensor measurements to determine the current flight state with respect to the target body and the desired landing site. With a future transition from single exploration missions to more frequent first exploration and then exploitation missions, the implementation and operation of these missions changes, since it can be expected that a ground infrastructure on the target body is available in the vicinity of the landing site. In a previous paper, the impact of a single ground-based beacon on the navigation performance was investigated depending on the type of radiometric measurements and on the location of the beacon with respect to the landing site. This paper extends this investigation on options for ground-based multiple beacons supporting the on-board navigation system. It analyzes the impact on the achievable navigation accuracy. For that purpose, the paper introduces briefly the existing navigation architecture based on optical navigation and its extension with radiometric measurements. The same scenario of lunar landing as in the previous paper is simulated. The results are analyzed and discussed. They show a single beacon at a large distance along the landing trajectory and multiple beacons close to the landing site can improve the navigation performance. The results show how large the landing area can be increased where a sufficient navigation performance is achieved using the beacons.

  13. Overshadowing of geometric cues by a beacon in a spatial navigation task.

    PubMed

    Redhead, Edward S; Hamilton, Derek A; Parker, Matthew O; Chan, Wai; Allison, Craig

    2013-06-01

    In three experiments, we examined whether overshadowing of geometric cues by a discrete landmark (beacon) is due to the relative saliences of the cues. Using a virtual water maze task, human participants were required to locate a platform marked by a beacon in a distinctively shaped pool. In Experiment 1, the beacon overshadowed geometric cues in a trapezium, but not in an isosceles triangle. The longer escape latencies during acquisition in the trapezium control group with no beacon suggest that the geometric cues in the trapezium were less salient than those in the triangle. In Experiment 2, we evaluated whether generalization decrement, caused by the removal of the beacon at test, could account for overshadowing. An additional beacon was placed in an alternative corner. For the control groups, the beacons were identical; for the overshadow groups, they were visually unique. Overshadowing was again found in the trapezium. In Experiment 3, we tested whether the absence of overshadowing in the triangle was due to the geometric cues being more salient than the beacon. Following training, the beacon was relocated to a different corner. Participants approached the beacon rather than the trained platform corner, suggesting that the beacon was more salient. These results suggest that associative processes do not fully explain cue competition in the spatial domain.

  14. Weak beacon detection for air-to-ground optical wireless link establishment.

    PubMed

    Han, Yaoqiang; Dang, Anhong; Tang, Junxiong; Guo, Hong

    2010-02-01

    In an air-to-ground free-space optical communication system, strong background interference seriously affects the beacon detection, which makes it difficult to establish the optical link. In this paper, we propose a correlation beacon detection scheme under strong background interference conditions. As opposed to traditional beacon detection schemes, the beacon is modulated by an m-sequence at the transmitting terminal with a digital differential matched filter (DDMF) array introduced at the receiving end to detect the modulated beacon. This scheme is capable of suppressing both strong interference and noise by correlation reception of the received image sequence. In addition, the DDMF array enables each pixel of the image sensor to have its own DDMF of the same structure to process its received image sequence in parallel, thus it makes fast beacon detection possible. Theoretical analysis and an outdoor experiment have been demonstrated and show that the proposed scheme can realize fast and effective beacon detection under strong background interference conditions. Consequently, the required beacon transmission power can also be reduced dramatically.

  15. Audible Beaconing with Accessible Pedestrian Signals

    PubMed Central

    Barlow, Janet M.; Scott, Alan C.; Bentzen, Billie Louise

    2010-01-01

    Purpose Although Accessible Pedestrian Signals (APS) are often assumed to provide wayfinding information, the type of APS that has been typically installed in the U.S has not had positive effects on finding crosswalks, locating pushbuttons, or providing directional guidance. This paper reports the results of research on crossings by blind pedestrians at complex signalized intersections, before and after the installation of APS with innovative audible beaconing features, designed to improve wayfinding. Methods Objective data on measures of street crossing performance by 56 participants was obtained at four intersections, two each in Charlotte, NC, and Portland, OR. Results In the first round of testing, APS with beaconing features resulted in only slightly improved wayfinding. Revisions to the audible beaconing features resulted in improved performance on four measures of wayfinding as compared to the pre-installation condition: beginning crossings within the crosswalk, ending crossings within the crosswalk, independence in finding the starting location, and independence in aligning to cross. Implications for Practice Use of APS that provide beaconing from the far-end of the crosswalk show promise of improving wayfinding at street crossings. PMID:20622978

  16. Beacon data acquisition and display system

    DOEpatents

    Skogmo, David G.; Black, Billy D.

    1991-01-01

    A system for transmitting aircraft beacon information received by a secondary surveillance radar through telephone lines to a remote display includes a digitizer connected to the radar for preparing a serial file of data records containing position and identification information of the beacons detected by each sweep of the radar. This information is transmitted through the telephone lines to a remote computer where it is displayed.

  17. 14 CFR 171.321 - DME and marker beacon performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false DME and marker beacon performance... (MLS) § 171.321 DME and marker beacon performance requirements. (a) The DME equipment must meet the..._regulations/ibr_locations.html. (b) MLS marker beacon equipment must meet the performance requirements...

  18. Beacon data acquisition and display system

    DOEpatents

    Skogmo, D.G.; Black, B.D.

    1991-12-17

    A system for transmitting aircraft beacon information received by a secondary surveillance radar through telephone lines to a remote display includes a digitizer connected to the radar for preparing a serial file of data records containing position and identification information of the beacons detected by each sweep of the radar. This information is transmitted through the telephone lines to a remote computer where it is displayed. 6 figures.

  19. Addressing Beacon re-identification attacks: quantification and mitigation of privacy risks.

    PubMed

    Raisaro, Jean Louis; Tramèr, Florian; Ji, Zhanglong; Bu, Diyue; Zhao, Yongan; Carey, Knox; Lloyd, David; Sofia, Heidi; Baker, Dixie; Flicek, Paul; Shringarpure, Suyash; Bustamante, Carlos; Wang, Shuang; Jiang, Xiaoqian; Ohno-Machado, Lucila; Tang, Haixu; Wang, XiaoFeng; Hubaux, Jean-Pierre

    2017-07-01

    The Global Alliance for Genomics and Health (GA4GH) created the Beacon Project as a means of testing the willingness of data holders to share genetic data in the simplest technical context-a query for the presence of a specified nucleotide at a given position within a chromosome. Each participating site (or "beacon") is responsible for assuring that genomic data are exposed through the Beacon service only with the permission of the individual to whom the data pertains and in accordance with the GA4GH policy and standards.While recognizing the inference risks associated with large-scale data aggregation, and the fact that some beacons contain sensitive phenotypic associations that increase privacy risk, the GA4GH adjudged the risk of re-identification based on the binary yes/no allele-presence query responses as acceptable. However, recent work demonstrated that, given a beacon with specific characteristics (including relatively small sample size and an adversary who possesses an individual's whole genome sequence), the individual's membership in a beacon can be inferred through repeated queries for variants present in the individual's genome.In this paper, we propose three practical strategies for reducing re-identification risks in beacons. The first two strategies manipulate the beacon such that the presence of rare alleles is obscured; the third strategy budgets the number of accesses per user for each individual genome. Using a beacon containing data from the 1000 Genomes Project, we demonstrate that the proposed strategies can effectively reduce re-identification risk in beacon-like datasets. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  20. Addressing Beacon re-identification attacks: quantification and mitigation of privacy risks

    PubMed Central

    Zhao, Yongan; Carey, Knox; Lloyd, David; Sofia, Heidi; Baker, Dixie; Flicek, Paul; Shringarpure, Suyash; Bustamante, Carlos; Wang, Shuang; Jiang, Xiaoqian; Ohno-Machado, Lucila; Tang, Haixu; Wang, XiaoFeng; Hubaux, Jean-Pierre

    2018-01-01

    The Global Alliance for Genomics and Health (GA4GH) created the Beacon Project as a means of testing the willingness of data holders to share genetic data in the simplest technical context—a query for the presence of a specified nucleotide at a given position within a chromosome. Each participating site (or “beacon”) is responsible for assuring that genomic data are exposed through the Beacon service only with the permission of the individual to whom the data pertains and in accordance with the GA4GH policy and standards. While recognizing the inference risks associated with large-scale data aggregation, and the fact that some beacons contain sensitive phenotypic associations that increase privacy risk, the GA4GH adjudged the risk of re-identification based on the binary yes/no allele-presence query responses as acceptable. However, recent work demonstrated that, given a beacon with specific characteristics (including relatively small sample size and an adversary who possesses an individual’s whole genome sequence), the individual’s membership in a beacon can be inferred through repeated queries for variants present in the individual’s genome. In this paper, we propose three practical strategies for reducing re-identification risks in beacons. The first two strategies manipulate the beacon such that the presence of rare alleles is obscured; the third strategy budgets the number of accesses per user for each individual genome. Using a beacon containing data from the 1000 Genomes Project, we demonstrate that the proposed strategies can effectively reduce re-identification risk in beacon-like datasets. PMID:28339683

  1. Laser Transmitter Aims At Laser Beacon

    NASA Technical Reports Server (NTRS)

    Hemmati, Hamid; Lesh, James R.

    1993-01-01

    Transmitter part of developmental optical communication system. Compact, lightweight, partially-self-aiming laser transmitter built to verify some capabilities of developmental free-space optical communication system. Design capable of providing 0.5 Mbps data return over range equal to Moon-Earth distance. Breadboard of transmitting terminal constructed and tested in laboratory. Prototype transmitter includes receiving circuitry that keeps it aimed at beacon, once brought into initial alignment within about 1.7 degrees of line of sight to beacon.

  2. Synthesis and Characterization of a Magnetically Active 19F Molecular Beacon.

    PubMed

    Dempsey, Megan E; Marble, Hetal D; Shen, Tun-Li; Fawzi, Nicolas L; Darling, Eric M

    2018-02-21

    Gene expression is used extensively to describe cellular characteristics and behaviors; however, most methods of assessing gene expression are unsuitable for living samples, requiring destructive processes such as fixation or lysis. Recently, molecular beacons have become a viable tool for live-cell imaging of mRNA molecules in situ. Historically, beacon-mediated imaging has been limited to fluorescence-based approaches. We propose the design and synthesis of a novel molecular beacon for magnetic resonance detection of any desired target nucleotide sequence. The biologically compatible synthesis incorporates commonly used bioconjugation reactions in aqueous conditions and is accessible for laboratories without extensive synthesis capabilities. The resulting beacon uses fluorine ( 19 F) as a reporter, which is broadened, or turned "off", via paramagnetic relaxation enhancement from a stabilized nitroxide radical spin label when the beacon is not bound to its nucleic acid target. Therefore, the 19 F NMR signal of the beacon is quenched in its hairpin conformation when the spin label and the 19 F substituent are held in proximity, but the signal is recovered upon beacon hybridization to its specific complementary nucleotide sequence by physical separation of the radical from the 19 F reporter. This study establishes a path for magnetic resonance-based assessment of specific mRNA expression, providing new possibilities for applying molecular beacon technology in living systems.

  3. Development of a Universal RNA Beacon for Exogenous Gene Detection

    PubMed Central

    Guo, Yuanjian; Lu, Zhongju; Cohen, Ira Stephen

    2015-01-01

    Stem cell therapy requires a nontoxic and high-throughput method to achieve a pure cell population to prevent teratomas that can occur if even one cell in the implant has not been transformed. A promising method to detect and separate cells expressing a particular gene is RNA beacon technology. However, developing a successful, specific beacon to a particular transfected gene can take months to develop and in some cases is impossible. Here, we report on an off-the-shelf universal beacon that decreases the time and cost of applying beacon technology to select any living cell population transfected with an exogenous gene. PMID:25769653

  4. Development of a universal RNA beacon for exogenous gene detection.

    PubMed

    Guo, Yuanjian; Lu, Zhongju; Cohen, Ira Stephen; Scarlata, Suzanne

    2015-05-01

    Stem cell therapy requires a nontoxic and high-throughput method to achieve a pure cell population to prevent teratomas that can occur if even one cell in the implant has not been transformed. A promising method to detect and separate cells expressing a particular gene is RNA beacon technology. However, developing a successful, specific beacon to a particular transfected gene can take months to develop and in some cases is impossible. Here, we report on an off-the-shelf universal beacon that decreases the time and cost of applying beacon technology to select any living cell population transfected with an exogenous gene. ©AlphaMed Press.

  5. Quantum dot-based molecular beacon to monitor intracellular microRNAs.

    PubMed

    Lee, Jonghwan; Moon, Sung Ung; Lee, Yong Seung; Ali, Bahy A; Al-Khedhairy, Abdulaziz A; Ali, Daoud; Ahmed, Javed; Al Salem, Abdullah M; Kim, Soonhag

    2015-06-02

    Fluorescence monitoring of endogenous microRNA (miRNA or miR) activity related to neuronal development using nano-sized materials provides crucial information on miRNA expression patterns in a noninvasive manner. In this study, we report a new method to monitor intracellular miRNA124a using quantum dot-based molecular beacon (R9-QD-miR124a beacon). The R9-QD-miR124a beacon was constructed using QDs and two probes, miR124a-targeting oligomer and arginine rich cell-penetrating peptide (R9 peptide). The miR124a-targeting oligomer contains a miR124a binging sequence and a black hole quencher 1 (BHQ1). In the absence of target miR124a, the R9-QD-miR124a beacon forms a partial duplex beacon and remained in quenched state because the BHQ1 quenches the fluorescence signal of the R9-QD-miR124a beacon. The binding of miR124a to the miR124a binding sequence of the miR124a-targeting oligomer triggered the separation of the BHQ1 quencher and subsequent signal-on of a red fluorescence signal. Moreover, enhanced cellular uptake was achieved by conjugation with the R9 peptide, which resulted in increased fluorescent signal of the R9-QD-miR124a beacons in P19 cells during neurogenesis due to the endogenous expression of miR124a.

  6. Beach Advisory and Closing Online Notification (BEACON) system

    EPA Pesticide Factsheets

    Beach Advisory and Closing Online Notification system (BEACON) is a colletion of state and local data reported to EPA about beach closings and advisories. BEACON is the public-facing query of the Program tracking, Beach Advisories, Water quality standards, and Nutrients database (PRAWN) which tracks beach closing and advisory information.

  7. Rayleigh beacon for measuring the surface profile of a radio telescope.

    PubMed

    Padin, S

    2014-12-01

    Millimeter-wavelength Rayleigh scattering from water droplets in a cloud is proposed as a means of generating a bright beacon for measuring the surface profile of a radio telescope. A λ=3  mm transmitter, with an output power of a few watts, illuminating a stratiform cloud, can generate a beacon with the same flux as Mars in 10 GHz bandwidth, but the beacon has a narrow line width, so it is extremely bright. The key advantage of the beacon is that it can be used at any time, and positioned anywhere in the sky, as long as there are clouds.

  8. Monopulse azimuth measurement in the ATC Radar Beacon System

    DOT National Transportation Integrated Search

    1971-12-01

    A review is made of the application of sum-difference beam : techniques to the ATC Radar Beacon System. A detailed error analysis : is presented for the case of a monopulse azimuth measurement based : on the existing beacon antenna with a modified fe...

  9. In vitro quantification of specific microRNA using molecular beacons

    PubMed Central

    Baker, Meredith B.; Bao, Gang; Searles, Charles D.

    2012-01-01

    MicroRNAs (miRNAs), a class of non-coding RNAs, have become a major focus of molecular biology research because of their diverse genomic origin and ability to regulate an array of cellular processes. Although the biological functions of miRNA are yet to be fully understood, tissue levels of specific miRNAs have been shown to correlate with pathological development of disease. Here, we demonstrate that molecular beacons can readily distinguish mature- and pre-miRNAs, and reliably quantify miRNA expression. We found that molecular beacons with DNA, RNA and combined locked nucleic acid (LNA)–DNA backbones can all detect miRNAs of low (<1 nM) concentrations in vitro, with RNA beacons having the highest detection sensitivity. Furthermore, we found that molecular beacons have the potential to distinguish miRNAs that have slight variations in their nucleotide sequence. These results suggest that the molecular beacon-based approach to assess miRNA expression and distinguish mature and precursor miRNA species is quite robust, and has the promise for assessing miRNA levels in biological samples. PMID:22110035

  10. Accurate beacon positioning method for satellite-to-ground optical communication.

    PubMed

    Wang, Qiang; Tong, Ling; Yu, Siyuan; Tan, Liying; Ma, Jing

    2017-12-11

    In satellite laser communication systems, accurate positioning of the beacon is essential for establishing a steady laser communication link. For satellite-to-ground optical communication, the main influencing factors on the acquisition of the beacon are background noise and atmospheric turbulence. In this paper, we consider the influence of background noise and atmospheric turbulence on the beacon in satellite-to-ground optical communication, and propose a new locating algorithm for the beacon, which takes the correlation coefficient obtained by curve fitting for image data as weights. By performing a long distance laser communication experiment (11.16 km), we verified the feasibility of this method. Both simulation and experiment showed that the new algorithm can accurately obtain the position of the centroid of beacon. Furthermore, for the distortion of the light spot through atmospheric turbulence, the locating accuracy of the new algorithm was 50% higher than that of the conventional gray centroid algorithm. This new approach will be beneficial for the design of satellite-to ground optical communication systems.

  11. SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amro, H; Chetty, I; Gordon, J

    2014-06-01

    Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in themore » phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation.« less

  12. 33 CFR 149.580 - What are the requirements for a radar beacon?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... radar beacon? 149.580 Section 149.580 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Navigation Miscellaneous § 149.580 What are the requirements for a radar beacon? (a) A radar beacon (RACON... Morse code character, the length of which does not exceed 25 percent of the radar range expected to be...

  13. 33 CFR 149.580 - What are the requirements for a radar beacon?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... radar beacon? 149.580 Section 149.580 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Navigation Miscellaneous § 149.580 What are the requirements for a radar beacon? (a) A radar beacon (RACON... Morse code character, the length of which does not exceed 25 percent of the radar range expected to be...

  14. 33 CFR 149.580 - What are the requirements for a radar beacon?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... radar beacon? 149.580 Section 149.580 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Navigation Miscellaneous § 149.580 What are the requirements for a radar beacon? (a) A radar beacon (RACON... Morse code character, the length of which does not exceed 25 percent of the radar range expected to be...

  15. 33 CFR 149.580 - What are the requirements for a radar beacon?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... radar beacon? 149.580 Section 149.580 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Navigation Miscellaneous § 149.580 What are the requirements for a radar beacon? (a) A radar beacon (RACON... Morse code character, the length of which does not exceed 25 percent of the radar range expected to be...

  16. 33 CFR 149.580 - What are the requirements for a radar beacon?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... radar beacon? 149.580 Section 149.580 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Navigation Miscellaneous § 149.580 What are the requirements for a radar beacon? (a) A radar beacon (RACON... Morse code character, the length of which does not exceed 25 percent of the radar range expected to be...

  17. BEACON: automated tool for Bacterial GEnome Annotation ComparisON.

    PubMed

    Kalkatawi, Manal; Alam, Intikhab; Bajic, Vladimir B

    2015-08-18

    Genome annotation is one way of summarizing the existing knowledge about genomic characteristics of an organism. There has been an increased interest during the last several decades in computer-based structural and functional genome annotation. Many methods for this purpose have been developed for eukaryotes and prokaryotes. Our study focuses on comparison of functional annotations of prokaryotic genomes. To the best of our knowledge there is no fully automated system for detailed comparison of functional genome annotations generated by different annotation methods (AMs). The presence of many AMs and development of new ones introduce needs to: a/ compare different annotations for a single genome, and b/ generate annotation by combining individual ones. To address these issues we developed an Automated Tool for Bacterial GEnome Annotation ComparisON (BEACON) that benefits both AM developers and annotation analysers. BEACON provides detailed comparison of gene function annotations of prokaryotic genomes obtained by different AMs and generates extended annotations through combination of individual ones. For the illustration of BEACON's utility, we provide a comparison analysis of multiple different annotations generated for four genomes and show on these examples that the extended annotation can increase the number of genes annotated by putative functions up to 27%, while the number of genes without any function assignment is reduced. We developed BEACON, a fast tool for an automated and a systematic comparison of different annotations of single genomes. The extended annotation assigns putative functions to many genes with unknown functions. BEACON is available under GNU General Public License version 3.0 and is accessible at: http://www.cbrc.kaust.edu.sa/BEACON/ .

  18. Switchable cucurbituril-bipyridine beacons.

    PubMed

    Sinha, Mantosh K; Reany, Ofer; Parvari, Galit; Karmakar, Ananta; Keinan, Ehud

    2010-08-09

    4-Aminobipyridine derivatives form strong inclusion complexes with cucurbit[6]uril, exhibiting remarkably large enhancements in fluorescence intensity and quantum yields. The remarkable complexation-induced pK(a) shift (DeltapK(a)=3.3) highlights the strong charge-dipole interaction upon binding. The reversible binding phenomenon can be used for the design of switchable beacons that can be incorporated into cascades of binding networks. This concept is demonstrated herein by three different applications: 1) a switchable fluorescent beacon for chemical sensing of transition metals and other ligands; 2) direct measurement of binding constants between cucurbit[6]uril and various nonfluorescent guest molecules; and 3) quantitative monitoring of biocatalytic reactions and determination of their kinetic parameters. The latter application is illustrated by the hydrolysis of an amide catalyzed by penicillin G acylase and by the elimination reaction of a beta-cabamoyloxy ketone catalyzed by aldolase antibody 38C2.

  19. Nucleic acid detection using BRET-beacons based on bioluminescent protein-DNA hybrids.

    PubMed

    Engelen, Wouter; van de Wiel, Kayleigh M; Meijer, Lenny H H; Saha, Bedabrata; Merkx, Maarten

    2017-03-02

    Bioluminescent molecular beacons have been developed using a modular design approach that relies on BRET between the bright luciferase NanoLuc and a Cy3 acceptor. While classical molecular beacons are hampered by background fluorescence and scattering, these BRET-beacons allow detection of low pM concentrations of nucleic acids directly in complex media.

  20. Collaborating To Help High-Risk Students Succeed. Beacon Guide.

    ERIC Educational Resources Information Center

    Chemeketa Community Coll., Salem, OR.

    The goal of the American Association of Community and Junior Colleges' Beacon Colleges Initiative is to disseminate information about exemplary collaborative programs and services. In Oregon, Chemeketa Community College is the Beacon College which has been working in association with five other community colleges in the state to build community…

  1. High efficiency low cost monolithic module for SARSAT distress beacons

    NASA Technical Reports Server (NTRS)

    Petersen, Wendell C.; Siu, Daniel P.

    1992-01-01

    The program objectives were to develop a highly efficient, low cost RF module for SARSAT beacons; achieve significantly lower battery current drain, amount of heat generated, and size of battery required; utilize MMIC technology to improve efficiency, reliability, packaging, and cost; and provide a technology database for GaAs based UHF RF circuit architectures. Presented in viewgraph form are functional block diagrams of the SARSAT distress beacon and beacon RF module as well as performance goals, schematic diagrams, predicted performances, and measured performances for the phase modulator and power amplifier.

  2. Beacons In Brief. P/PV In Brief. Issue 2

    ERIC Educational Resources Information Center

    Blank, Susan; Farley, Chelsea

    2004-01-01

    This second issue in P/PV's "In Brief" series focuses on the San Francisco Beacon Initiative and P/PV's recently released evaluation results. The Beacon Initiative established after-school programs in eight public schools in low-income San Francisco neighborhoods. P/PV's 36-month evaluation examined key developmental and academic outcomes.…

  3. SPHERES ultrasound beacon tester floats in Node 1 during Expedition 8

    NASA Image and Video Library

    2004-03-24

    ISS008-E-19132 (24 March 2004) --- The Synchronized Position Hold, Engage, Reorient, Experimental Satellites (SPHERES) Beacon / Beacon Tester floats in the Unity node of the International Space Station.

  4. Beacon Communities’ Public Health Initiatives: A Case Study Analysis

    PubMed Central

    Massoudi, Barbara L.; Marcial, Laura H.; Haque, Saira; Bailey, Robert; Chester, Kelley; Cunningham, Shellery; Riley, Amanda; Soper, Paula

    2014-01-01

    Introduction: The Beacon Communities for Public Health (BCPH) project was launched in 2011 to gain a better understanding of the range of activities currently being conducted in population- and public health by the Beacon Communities. The project highlighted the successes and challenges of these efforts with the aim of sharing this information broadly among the public health community. Background: The Beacon Community Program, designed to showcase technology-enabled, community-based initiatives to improve outcomes, focused on: building and strengthening health information technology (IT) infrastructure and exchange capabilities; translating investments in health IT to measureable improvements in cost, quality, and population health; and, developing innovative approaches to performance measurement, technology, and care delivery. Methods: Four multimethod case studies were conducted based on a modified sociotechnical framework to learn more about public health initiative implementation and use in the Beacon Communities. Our methodological approach included using document review and semistructured key informant interviews. NACCHO Model Practice Program criteria were used to select the public health initiatives included in the case studies. Findings: Despite differences among the case studies, common barriers and facilitators were found to be present in all areas of the sociotechnical framework application including structure, people, technology, tasks, overarching considerations, and sustainability. Overall, there were many more facilitators (range = 7–14) present for each Beacon compared to barriers (range = 4–6). Discussion: Four influential promising practices were identified through the work: forging strong and sustainable partnerships; ensuring a good task-technology fit and a flexible and iterative design; fostering technology acceptance; and, providing education and demonstrating value. Conclusions: A common weakness was the lack of a framework or model for

  5. Beacon communities' public health initiatives: a case study analysis.

    PubMed

    Massoudi, Barbara L; Marcial, Laura H; Haque, Saira; Bailey, Robert; Chester, Kelley; Cunningham, Shellery; Riley, Amanda; Soper, Paula

    2014-01-01

    The Beacon Communities for Public Health (BCPH) project was launched in 2011 to gain a better understanding of the range of activities currently being conducted in population- and public health by the Beacon Communities. The project highlighted the successes and challenges of these efforts with the aim of sharing this information broadly among the public health community. The Beacon Community Program, designed to showcase technology-enabled, community-based initiatives to improve outcomes, focused on: building and strengthening health information technology (IT) infrastructure and exchange capabilities; translating investments in health IT to measureable improvements in cost, quality, and population health; and, developing innovative approaches to performance measurement, technology, and care delivery. Four multimethod case studies were conducted based on a modified sociotechnical framework to learn more about public health initiative implementation and use in the Beacon Communities. Our methodological approach included using document review and semistructured key informant interviews. NACCHO Model Practice Program criteria were used to select the public health initiatives included in the case studies. Despite differences among the case studies, common barriers and facilitators were found to be present in all areas of the sociotechnical framework application including structure, people, technology, tasks, overarching considerations, and sustainability. Overall, there were many more facilitators (range = 7-14) present for each Beacon compared to barriers (range = 4-6). Four influential promising practices were identified through the work: forging strong and sustainable partnerships; ensuring a good task-technology fit and a flexible and iterative design; fostering technology acceptance; and, providing education and demonstrating value. A common weakness was the lack of a framework or model for the Beacon Communities evaluation work. Sharing a framework or approach

  6. An Interactive Real-Time Locating System Based on Bluetooth Low-Energy Beacon Network †

    PubMed Central

    Lin, You-Wei

    2018-01-01

    The ubiquity of Bluetooth-enabled smartphones and peripherals has brought tremendous convenience to our daily life. In recent years, Bluetooth beacons have also been gaining popularity in implementing a variety of innovative location-based services such as self-guided systems in exhibition centers. However, the broadcast-based beacon technology can only provide unidirectional communication. In case smartphone users would like to respond to the beacon messages, they have to rely on their own mobile Internet connections to send the information back to the backend system. Nevertheless, mobile Internet services may not be always available or too costly. In this work, we develop a real-time locating system based only on the Bluetooth low energy (BLE) technology to support interactive communications by combining the broadcast and mesh topology options to extend the applicability of beacon solutions. Specifically, we turn the smartphone into a beacon device and augment the beacon devices with the capability of forming a mesh network. The implementation result shows that our beacon devices can detect the presence of specific users at specific locations, and then the presence state can be sent to the application server via the relay of beacon devices. Moreover, the application server can send personalized location-based messages to the users, again via the relay of beacon devices. With the capability of relaying messages between the beacon devices, it would be convenient for developers to implement a variety of interactive applications such as tracking VIP customers at the airport, or tracking an elder with Alzheimer’s disease in the neighborhood. PMID:29883386

  7. An Interactive Real-Time Locating System Based on Bluetooth Low-Energy Beacon Network †.

    PubMed

    Lin, You-Wei; Lin, Chi-Yi

    2018-05-21

    The ubiquity of Bluetooth-enabled smartphones and peripherals has brought tremendous convenience to our daily life. In recent years, Bluetooth beacons have also been gaining popularity in implementing a variety of innovative location-based services such as self-guided systems in exhibition centers. However, the broadcast-based beacon technology can only provide unidirectional communication. In case smartphone users would like to respond to the beacon messages, they have to rely on their own mobile Internet connections to send the information back to the backend system. Nevertheless, mobile Internet services may not be always available or too costly. In this work, we develop a real-time locating system based only on the Bluetooth low energy (BLE) technology to support interactive communications by combining the broadcast and mesh topology options to extend the applicability of beacon solutions. Specifically, we turn the smartphone into a beacon device and augment the beacon devices with the capability of forming a mesh network. The implementation result shows that our beacon devices can detect the presence of specific users at specific locations, and then the presence state can be sent to the application server via the relay of beacon devices. Moreover, the application server can send personalized location-based messages to the users, again via the relay of beacon devices. With the capability of relaying messages between the beacon devices, it would be convenient for developers to implement a variety of interactive applications such as tracking VIP customers at the airport, or tracking an elder with Alzheimer’s disease in the neighborhood.

  8. Smartphone-Based Indoor Localization with Bluetooth Low Energy Beacons

    PubMed Central

    Zhuang, Yuan; Yang, Jun; Li, You; Qi, Longning; El-Sheimy, Naser

    2016-01-01

    Indoor wireless localization using Bluetooth Low Energy (BLE) beacons has attracted considerable attention after the release of the BLE protocol. In this paper, we propose an algorithm that uses the combination of channel-separate polynomial regression model (PRM), channel-separate fingerprinting (FP), outlier detection and extended Kalman filtering (EKF) for smartphone-based indoor localization with BLE beacons. The proposed algorithm uses FP and PRM to estimate the target’s location and the distances between the target and BLE beacons respectively. We compare the performance of distance estimation that uses separate PRM for three advertisement channels (i.e., the separate strategy) with that use an aggregate PRM generated through the combination of information from all channels (i.e., the aggregate strategy). The performance of FP-based location estimation results of the separate strategy and the aggregate strategy are also compared. It was found that the separate strategy can provide higher accuracy; thus, it is preferred to adopt PRM and FP for each BLE advertisement channel separately. Furthermore, to enhance the robustness of the algorithm, a two-level outlier detection mechanism is designed. Distance and location estimates obtained from PRM and FP are passed to the first outlier detection to generate improved distance estimates for the EKF. After the EKF process, the second outlier detection algorithm based on statistical testing is further performed to remove the outliers. The proposed algorithm was evaluated by various field experiments. Results show that the proposed algorithm achieved the accuracy of <2.56 m at 90% of the time with dense deployment of BLE beacons (1 beacon per 9 m), which performs 35.82% better than <3.99 m from the Propagation Model (PM) + EKF algorithm and 15.77% more accurate than <3.04 m from the FP + EKF algorithm. With sparse deployment (1 beacon per 18 m), the proposed algorithm achieves the accuracies of <3.88 m at 90% of the

  9. Smartphone-Based Indoor Localization with Bluetooth Low Energy Beacons.

    PubMed

    Zhuang, Yuan; Yang, Jun; Li, You; Qi, Longning; El-Sheimy, Naser

    2016-04-26

    Indoor wireless localization using Bluetooth Low Energy (BLE) beacons has attracted considerable attention after the release of the BLE protocol. In this paper, we propose an algorithm that uses the combination of channel-separate polynomial regression model (PRM), channel-separate fingerprinting (FP), outlier detection and extended Kalman filtering (EKF) for smartphone-based indoor localization with BLE beacons. The proposed algorithm uses FP and PRM to estimate the target's location and the distances between the target and BLE beacons respectively. We compare the performance of distance estimation that uses separate PRM for three advertisement channels (i.e., the separate strategy) with that use an aggregate PRM generated through the combination of information from all channels (i.e., the aggregate strategy). The performance of FP-based location estimation results of the separate strategy and the aggregate strategy are also compared. It was found that the separate strategy can provide higher accuracy; thus, it is preferred to adopt PRM and FP for each BLE advertisement channel separately. Furthermore, to enhance the robustness of the algorithm, a two-level outlier detection mechanism is designed. Distance and location estimates obtained from PRM and FP are passed to the first outlier detection to generate improved distance estimates for the EKF. After the EKF process, the second outlier detection algorithm based on statistical testing is further performed to remove the outliers. The proposed algorithm was evaluated by various field experiments. Results show that the proposed algorithm achieved the accuracy of <2.56 m at 90% of the time with dense deployment of BLE beacons (1 beacon per 9 m), which performs 35.82% better than <3.99 m from the Propagation Model (PM) + EKF algorithm and 15.77% more accurate than <3.04 m from the FP + EKF algorithm. With sparse deployment (1 beacon per 18 m), the proposed algorithm achieves the accuracies of <3.88 m at 90% of the

  10. Digital detection and processing of laser beacon signals for aircraft collision hazard warning

    NASA Technical Reports Server (NTRS)

    Sweet, L. M.; Miles, R. B.; Russell, G. F.; Tomeh, M. G.; Webb, S. G.; Wong, E. Y.

    1981-01-01

    A low-cost collision hazard warning system suitable for implementation in both general and commercial aviation is presented. Laser beacon systems are used as sources of accurate relative position information that are not dependent on communication between aircraft or with the ground. The beacon system consists of a rotating low-power laser beacon, detector arrays with special optics for wide angle acceptance and filtering of solar background light, microprocessors for proximity and relative trajectory computation, and pilot displays of potential hazards. The laser beacon system provides direct measurements of relative aircraft positions; using optimal nonlinear estimation theory, the measurements resulting from the current beacon sweep are combined with previous data to provide the best estimate of aircraft proximity, heading, minimium passing distance, and time to closest approach.

  11. 46 CFR 169.744 - Emergency position indicating radio beacon (EPIRB).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.744 Section 169.744 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... position indicating radio beacon (EPIRB). Each EPIRB must be marked with the vessel's name. ...

  12. 46 CFR 169.555 - Emergency position indicating radio beacon (EPIRB).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.555 Section 169.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... Emergency position indicating radio beacon (EPIRB). (a) Each vessel certificated for exposed waters must...

  13. Validation of the Calypso Surface Beacon Transponder.

    PubMed

    Belanger, Maxwell; Saleh, Ziad; Volpe, Tom; Margiasso, Rich; Li, Xiang; Chan, Maria; Zhu, Xiaofeng; Tang, Xiaoli

    2016-07-08

    Calypso L-shaped Surface Beacon transponder has recently become available for clinical applications. We herein conduct studies to validate the Surface Beacon transponder in terms of stability, reproducibility, orientation sensitivity, cycle rate dependence, and respiratory waveform tracking accuracy. The Surface Beacon was placed on a Quasar respiratory phantom and positioned at the isocenter with its two arms aligned with the lasers. Breathing waveforms were simulated, and the motion of the transponder was tracked. Stability and drift analysis: sinusoidal waveforms (200 cycles) were produced, and the amplitudes of phases 0% (inhale) and 50% (exhale) were recorded at each breathing cycle. The mean and standard deviation (SD) of the amplitudes were calculated. Linear least-squares fitting was performed to access the possible amplitude drift over the breathing cycles. Reproducibility: similar setting to stability and drift analysis, and the phantom generated 100 cycles of the sinusoidal waveform per run. The Calypso system's was re-setup for each run. Recorded amplitude and SD of 0% and 50% phase were compared between runs to assess contribution of Calypso electromagnetic array setup variation. Beacon orientation sensitivity: the Calypso tracks sinusoidal phantom motion with a defined angular offset of the beacon to assess its effect on SD and peak-to-peak amplitude. Rate dependence: sinusoidal motion was generated at cycle rates of 1 Hz, .33 Hz, and .2 Hz. Peak-to-peak displacement and SDs were assessed. Respiratory waveform tracking accuracy: the phantom reproduced recorded breathing cycles (by volunteers and patients) were tracked by the Calypso system. Deviation in tracking position from produced waveform was used to calculate SD throughout entire breathing cycle. Stability and drift analysis: Mean amplitude ± SD of phase 0% or 50% were 20.01 ± 0.04 mm and -19.65 ± 0.08 mm, respectively. No clinically significant drift was detected with drift measured as 5.1

  14. Validation of the Calypso Surface Beacon Transponder

    PubMed Central

    Saleh, Ziad; Volpe, Tom; Margiasso, Rich; Li, Xiang; Chan, Maria; Zhu, Xiaofeng; Tang, Xiaoli

    2016-01-01

    Calypso L‐shaped Surface Beacon transponder has recently become available for clinical applications. We herein conduct studies to validate the Surface Beacon transponder in terms of stability, reproducibility, orientation sensitivity, cycle rate dependence, and respiratory waveform tracking accuracy. The Surface Beacon was placed on a Quasar respiratory phantom and positioned at the isocenter with its two arms aligned with the lasers. Breathing waveforms were simulated, and the motion of the transponder was tracked. Stability and drift analysis: sinusoidal waveforms (200 cycles) were produced, and the amplitudes of phases 0% (inhale) and 50% (exhale) were recorded at each breathing cycle. The mean and standard deviation (SD) of the amplitudes were calculated. Linear least‐squares fitting was performed to access the possible amplitude drift over the breathing cycles. Reproducibility: similar setting to stability and drift analysis, and the phantom generated 100 cycles of the sinusoidal waveform per run. The Calypso system's was re‐setup for each run. Recorded amplitude and SD of 0% and 50% phase were compared between runs to assess contribution of Calypso electromagnetic array setup variation. Beacon orientation sensitivity: the Calypso tracks sinusoidal phantom motion with a defined angular offset of the beacon to assess its effect on SD and peak‐to‐peak amplitude. Rate dependence: sinusoidal motion was generated at cycle rates of 1 Hz, .33 Hz, and .2 Hz. Peak‐to‐peak displacement and SDs were assessed. Respiratory waveform tracking accuracy: the phantom reproduced recorded breathing cycles (by volunteers and patients) were tracked by the Calypso system. Deviation in tracking position from produced waveform was used to calculate SD throughout entire breathing cycle. Stability and drift analysis: Mean amplitude ± SD of phase 0% or 50% were 20.01±0.04 mm and ‐19.65±0.08 mm, respectively. No clinically significant drift was detected with drift

  15. Detection of MDR1 mRNA expression with optimized gold nanoparticle beacon

    NASA Astrophysics Data System (ADS)

    Zhou, Qiumei; Qian, Zhiyu; Gu, Yueqing

    2016-03-01

    MDR1 (multidrug resistance gene) mRNA expression is a promising biomarker for the prediction of doxorubicin resistance in clinic. However, the traditional technical process in clinic is complicated and cannot perform the real-time detection mRNA in living single cells. In this study, the expression of MDR1 mRNA was analyzed based on optimized gold nanoparticle beacon in tumor cells. Firstly, gold nanoparticle (AuNP) was modified by thiol-PEG, and the MDR1 beacon sequence was screened and optimized using a BLAST bioinformatics strategy. Then, optimized MDR1 molecular beacons were characterized by transmission electron microscope, UV-vis and fluorescence spectroscopies. The cytotoxicity of MDR1 molecular beacon on L-02, K562 and K562/Adr cells were investigated by MTT assay, suggesting that MDR1 molecular beacon was low inherent cytotoxicity. Dark field microscope was used to investigate the cellular uptake of hDAuNP beacon assisted with ultrasound. Finally, laser scanning confocal microscope images showed that there was a significant difference in MDR1 mRNA expression in K562 and K562/Adr cells, which was consistent with the results of q-PCR measurement. In summary, optimized MDR1 molecular beacon designed in this study is a reliable strategy for detection MDR1 mRNA expression in living tumor cells, and will be a promising strategy for in guiding patient treatment and management in individualized medication.

  16. 54. DETAIL OF GENERAL ELECTRIC AIRBORNE BEACON EQUIPMENT TEST SET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. DETAIL OF GENERAL ELECTRIC AIRBORNE BEACON EQUIPMENT TEST SET (LEFT) AND ASSOCIATED GOULD BRUSH CHART RECORDERS (RIGHT). ELAPSED TIME COUNTER SITS ATOP AIRBORNE BEACON EQUIPMENT TEST SET. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  17. A Place to Grow: Evaluation of the New York City Beacons. Final Report

    ERIC Educational Resources Information Center

    Warren, Constancia; Feist, Michelle; Nevarez, Nancy

    2002-01-01

    This study examined six Beacon centers, which are community centers located in public school buildings that offer a range of activities and services to participants of all ages, before and after school, in the evenings, and on weekends. Individual Beacons are managed by community-based organizations. The study examined how the Beacons provided…

  18. A Place To Grow: Evaluation of the New York City Beacons. Summary Report.

    ERIC Educational Resources Information Center

    Warren, Constancia; Feist, Michelle; Nevarez, Nancy

    This study examined six Beacon centers, which are community centers located in public school buildings that offer a range of activities and services to participants of all ages, before and after school, in the evenings, and on weekends. Individual Beacons are managed by community-based organizations. The study examined how the Beacons provided…

  19. Q-Band (37-41 GHz) Satellite Beacon Architecture for RF Propagation Experiments

    NASA Technical Reports Server (NTRS)

    Simmons, Rainee N.; Wintucky, Edwin G.

    2012-01-01

    In this paper, the design of a beacon transmitter that will be flown as a hosted payload on a geostationary satellite to enable propagation experiments at Q-band (37-41 GHz) frequencies is presented. The beacon uses a phased locked loop stabilized dielectric resonator oscillator and a solid-state power amplifier to achieve the desired output power. The satellite beacon antenna is configured as an offset-fed cut-paraboloidal reflector.

  20. 46 CFR 169.831 - Emergency position indicating radio beacon (EPIRB).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.831 Section 169.831 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... radio beacon (EPIRB). The master shall ensure that— (a) The EPIRB required in § 169.555 of this...

  1. Quick acquisition and recognition method for the beacon in deep space optical communications.

    PubMed

    Wang, Qiang; Liu, Yuefei; Ma, Jing; Tan, Liying; Yu, Siyuan; Li, Changjiang

    2016-12-01

    In deep space optical communications, it is very difficult to acquire the beacon given the long communication distance. Acquisition efficiency is essential for establishing and holding the optical communication link. Here we proposed a quick acquisition and recognition method for the beacon in deep optical communications based on the characteristics of the deep optical link. To identify the beacon from the background light efficiently, we utilized the maximum similarity between the collecting image and the reference image for accurate recognition and acquisition of the beacon in the area of uncertainty. First, the collecting image and the reference image were processed by Fourier-Mellin. Second, image sampling and image matching were applied for the accurate positioning of the beacon. Finally, the field programmable gate array (FPGA)-based system was used to verify and realize this method. The experimental results showed that the acquisition time for the beacon was as fast as 8.1s. Future application of this method in the system design of deep optical communication will be beneficial.

  2. Digital beacon receiver for ionospheric TEC measurement developed with GNU Radio

    NASA Astrophysics Data System (ADS)

    Yamamoto, M.

    2008-11-01

    A simple digital receiver named GNU Radio Beacon Receiver (GRBR) was developed for the satellite-ground beacon experiment to measure the ionospheric total electron content (TEC). The open-source software toolkit for the software defined radio, GNU Radio, is utilized to realize the basic function of the receiver and perform fast signal processing. The software is written in Python for a LINUX PC. The open-source hardware called Universal Software Radio Peripheral (USRP), which best matches the GNU Radio, is used as a front-end to acquire the satellite beacon signals of 150 and 400 MHz. The first experiment was successful as results from GRBR showed very good agreement to those from the co-located analog beacon receiver. Detailed design information and software codes are open at the URL http://www.rish.kyoto-u.ac.jp/digitalbeacon/.

  3. Power-Efficient Beacon Recognition Method Based on Periodic Wake-Up for Industrial Wireless Devices

    PubMed Central

    Lee, Donghun; Jang, Ingook; Choi, Jinchul; Son, Youngsung

    2018-01-01

    Energy harvester-integrated wireless devices are attractive for generating semi-permanent power from wasted energy in industrial environments. The energy-harvesting wireless devices may have difficulty in their communication with access points due to insufficient power supply for beacon recognition during network initialization. In this manuscript, we propose a novel method of beacon recognition based on wake-up control to reduce instantaneous power consumption in the initialization procedure. The proposed method applies a moving window for the periodic wake-up of the wireless devices. For unsynchronized wireless devices, beacons are always located in the same positions within each beacon interval even though the starting offsets are unknown. Using these characteristics, the moving window checks the existence of the beacon associated withspecified resources in a beacon interval, checks again for neighboring resources at the next beacon interval, and so on. This method can reduce instantaneous power and generates a surplus of charging time. Thus, the proposed method alleviates the problems of power insufficiency in the network initialization. The feasibility of the proposed method is evaluated using computer simulations of power shortage in various energy-harvesting conditions. PMID:29673206

  4. Power-Efficient Beacon Recognition Method Based on Periodic Wake-Up for Industrial Wireless Devices.

    PubMed

    Song, Soonyong; Lee, Donghun; Jang, Ingook; Choi, Jinchul; Son, Youngsung

    2018-04-17

    Energy harvester-integrated wireless devices are attractive for generating semi-permanent power from wasted energy in industrial environments. The energy-harvesting wireless devices may have difficulty in their communication with access points due to insufficient power supply for beacon recognition during network initialization. In this manuscript, we propose a novel method of beacon recognition based on wake-up control to reduce instantaneous power consumption in the initialization procedure. The proposed method applies a moving window for the periodic wake-up of the wireless devices. For unsynchronized wireless devices, beacons are always located in the same positions within each beacon interval even though the starting offsets are unknown. Using these characteristics, the moving window checks the existence of the beacon associated withspecified resources in a beacon interval, checks again for neighboring resources at the next beacon interval, and so on. This method can reduce instantaneous power and generates a surplus of charging time. Thus, the proposed method alleviates the problems of power insufficiency in the network initialization. The feasibility of the proposed method is evaluated using computer simulations of power shortage in various energy-harvesting conditions.

  5. Development of an aptamer beacon for detection of interferon-gamma.

    PubMed

    Tuleuova, Nazgul; Jones, Caroline N; Yan, Jun; Ramanculov, Erlan; Yokobayashi, Yohei; Revzin, Alexander

    2010-03-01

    Traditional antibody-based affinity sensing strategies employ multiple reagents and washing steps and are unsuitable for real-time detection of analyte binding. Aptamers, on the other hand, may be designed to monitor binding events directly, in real-time, without the need for secondary labels. The goal of the present study was to design an aptamer beacon for fluorescence resonance energy transfer (FRET)-based detection of interferon-gamma (IFN-gamma)--an important inflammatory cytokine. Variants of DNA aptamer modified with biotin moieties and spacers were immobilized on avidin-coated surfaces and characterized by surface plasmon resonance (SPR). The SPR studies showed that immobilization of aptamer via the 3' end resulted in the best binding IFN-gamma (K(d) = 3.44 nM). This optimal aptamer variant was then used to construct a beacon by hybridizing fluorophore-labeled aptamer with an antisense oligonucleotide strand carrying a quencher. SPR studies revealed that IFN-gamma binding with an aptamer beacon occurred within 15 min of analyte introduction--suggesting dynamic replacement of the quencher-complementary strand by IFN-gamma molecules. To further highlight biosensing applications, aptamer beacon molecules were immobilized inside microfluidic channels and challenged with varying concentration of analyte. Fluorescence microscopy revealed low fluorescence in the absence of analyte and high fluorescence after introduction of IFN-gamma. Importantly, unlike traditional antibody-based immunoassays, the signal was observed directly upon binding of analyte without the need for multiple washing steps. The surface immobilized aptamer beacon had a linear range from 5 to 100 nM and a lower limit of detection of 5 nM IFN-gamma. In conclusion, we designed a FRET-based aptamer beacon for monitoring of an inflammatory cytokine-IFN-gamma. In the future, this biosensing strategy will be employed to monitor dynamics of cytokine production by the immune cells.

  6. Autonomous navigation using lunar beacons

    NASA Technical Reports Server (NTRS)

    Khatib, A. R.; Ellis, J.; French, J.; Null, G.; Yunck, T.; Wu, S.

    1983-01-01

    The concept of using lunar beacon signal transmission for on-board navigation for earth satellites and near-earth spacecraft is described. The system would require powerful transmitters on the earth-side of the moon's surface and black box receivers with antennae and microprocessors placed on board spacecraft for autonomous navigation. Spacecraft navigation requires three position and three velocity elements to establish location coordinates. Two beacons could be soft-landed on the lunar surface at the limits of allowable separation and each would transmit a wide-beam signal with cones reaching GEO heights and be strong enough to be received by small antennae in near-earth orbit. The black box processor would perform on-board computation with one-way Doppler/range data and dynamical models. Alternatively, GEO satellites such as the GPS or TDRSS spacecraft can be used with interferometric techniques to provide decimeter-level accuracy for aircraft navigation.

  7. Accelerated Adoption of Advanced Health Information Technology in Beacon Community Health Centers.

    PubMed

    Jones, Emily; Wittie, Michael

    2015-01-01

    To complement national and state-level HITECH Act programs, 17 Beacon communities were funded to fuel community-wide use of health information technology to improve quality. Health centers in Beacon communities received supplemental funding. This article explores the association between participation in the Beacon program and the adoption of electronic health records. Using the 2010-2012 Uniform Data System, trends in health information technology adoption among health centers located within and outside of Beacon communities were explored using differences in mean t tests and multivariate logistic regression. Electronic health record adoption was widespread and rapidly growing in all health centers, especially quality improvement functionalities: structured data capture, order and results management, and clinical decision support. Adoption lagged for functionalities supporting patient engagement, performance measurement, care coordination, and public health. The use of advanced functionalities such as care coordination grew faster in Beacon health centers, and Beacon health centers had 1.7 times higher odds of adopting health records with basic safety and quality functionalities in 2010-2012. Three factors likely underlie these findings: technical assistance, community-wide activation supporting health information exchange, and the layering of financial incentives. Additional technical assistance and community-wide activation is needed to support the use of functionalities that are currently lagging. © Copyright 2015 by the American Board of Family Medicine.

  8. Crescent Evaluation : appendix F : state-line beacon project : user case studies

    DOT National Transportation Integrated Search

    1994-02-01

    The essence of the AVI "Beacon" concept as it applies to the HELP organization would be to provide location, date, and tune information from the roadside to the on-board computer (OBC). A roadside transmit beacon would be located on the state lines a...

  9. Pedestrian and motorists' actions at pedestrian hybrid beacon sites: findings from a pilot study.

    PubMed

    Pulugurtha, Srinivas S; Self, Debbie R

    2015-01-01

    This paper focuses on an analysis of pedestrian and motorists' actions at sites with pedestrian hybrid beacons and assesses their effectiveness in improving the safety of pedestrians. Descriptive and statistical analyses (one-tail two-sample T-test and two-proportion Z-test) were conducted using field data collected during morning and evening peak hours at three study sites in the city of Charlotte, NC, before and after the installation of pedestrian hybrid beacons. Further, an analysis was conducted to assess the change in pedestrian and motorists' actions over time (before the installation; 1 month, 3 months, 6 months, and 12 months after the installation). Results showed an increase in average traffic speed at one of the pedestrian hybrid beacon sites while no specific trends were observed at the other two pedestrian hybrid beacon sites. A decrease in the number of motorists not yielding to pedestrians, pedestrians trapped in the middle of the street, and pedestrian-vehicle conflicts were observed at all the three pedestrian hybrid beacon sites. The installation of pedestrian hybrid beacons did not have a negative effect on pedestrian actions at two out of the three sites. Improvements seem to be relatively more consistent 3 months after the installation of the pedestrian hybrid beacon.

  10. Energy-Efficient BOP-Based Beacon Transmission Scheduling in Wireless Sensor Networks

    NASA Astrophysics Data System (ADS)

    Kim, Eui-Jik; Youm, Sungkwan; Choi, Hyo-Hyun

    Many applications in wireless sensor networks (WSNs) require the energy efficiency and scalability. Although IEEE 802.15.4/Zigbee which is being considered as general technology for WSNs enables the low duty-cycling with time synchronization of all the nodes in network, it still suffer from its low scalability due to the beacon frame collision. Recently, various algorithms to resolve this problem are proposed. However, their manners to implement are somewhat ambiguous and the degradation of energy/communication efficiency is serious by the additional overhead. This paper describes an Energy-efficient BOP-based Beacon transmission Scheduling (EBBS) algorithm. EBBS is the centralized approach, in which a resource-sufficient node called as Topology Management Center (TMC) allocates the time slots to transmit a beacon frame to the nodes and manages the active/sleep schedules of them. We also propose EBBS with Adaptive BOPL (EBBS-AB), to adjust the duration to transmit beacon frames in every beacon interval, adaptively. Simulation results show that by using the proposed algorithm, the energy efficiency and the throughput of whole network can be significantly improved. EBBS-AB is also more effective for the network performance when the nodes are uniformly deployed on the sensor field rather than the case of random topologies.

  11. Detection of DNA damage by using hairpin molecular beacon probes and graphene oxide.

    PubMed

    Zhou, Jie; Lu, Qian; Tong, Ying; Wei, Wei; Liu, Songqin

    2012-09-15

    A hairpin molecular beacon tagged with carboxyfluorescein in combination with graphene oxide as a quencher reagent was used to detect the DNA damage by chemical reagents. The fluorescence of molecular beacon was quenched sharply by graphene oxide; while in the presence of its complementary DNA the quenching efficiency decreased because their hybridization prevented the strong adsorbability of molecular beacon on graphene oxide. If the complementary DNA was damaged by a chemical reagent and could not form intact duplex structure with molecular beacon, more molecular beacon would adsorb on graphene oxide increasing the quenching efficiency. Thus, damaged DNA could be detected based on different quenching efficiencies afforded by damaged and intact complementary DNA. The damage effects of chlorpyrifos-methyl and three metabolites of styrene such as mandelieaeids, phenylglyoxylieaeids and epoxystyrene on DNA were studied as models. The method for detection of DNA damage was reliable, rapid and simple compared to the biological methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Q-Band (37 to 41 GHz) Satellite Beacon Architecture for RF Propagation Experiments

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    In this paper, the design of a beacon transmitter that will be flown as a hosted payload on a geostationary satellite to enable propagation experiments at Q-band (37 to 41 GHz) frequencies is presented. The beacon uses a phased locked loop stabilized dielectric resonator oscillator and a solid-state power amplifier to achieve the desired output power. The satellite beacon antenna is configured as an offset-fed cutparaboloidal reflector.

  13. Marking emergency exits and evacuation routes with sound beacons utilizing the precedence effect

    NASA Astrophysics Data System (ADS)

    van Wijngaarden, Sander J.; Bronkhorst, Adelbert W.; Boer, Louis C.

    2004-05-01

    Sound beacons can be extremely useful during emergency evacuations, especially when vision is obscured by smoke. When exits are marked with suitable sound sources, people can find these using only their capacity for directional hearing. Unfortunately, unless very explicit instructions were given, sound beacons currently commercially available (based on modulated noise) led to disappointing results during an evacuation experiment in a traffic tunnel. Only 19% out of 65 subjects were able to find an exit by ear. A signal designed to be more self-explanatory and less hostile-sounding (alternating chime signal and spoken message ``exit here'') increased the success rate to 86%. In a more complex environment-a mock-up of a ship's interior-routes to the exit were marked using multiple beacons. By applying carefully designed time delays between successive beacons, the direction of the route was marked, utilizing the precedence effect. Out of 34 subjects, 71% correctly followed the evacuation route by ear (compared to 24% for a noise signal as used in commercially available beacons). Even when subjects were forced to make a worst-case left-right decision at a T-junction, between two beacons differing only in arrival of the first wave front, 77% made the right decision.

  14. DNA Duplex-Based Photodynamic Molecular Beacon for Targeted Killing of Retinoblastoma Cell.

    PubMed

    Wei, Yanchun; Lu, Cuixia; Chen, Qun; Xing, Da

    2016-11-01

    Retinoblastoma (RB) is the most common primary intraocular malignancy of infancy. An alternative RB treatment protocol is proposed and tested. It is based on a photodynamic therapy (PDT) with a designed molecular beacon that specifically targets the murine double minute x (MDMX) high-expressed RB cells. A MDMX mRNA triggered photodynamic molecular beacon is designed by binding a photosensitizer molecule (pyropheophorbide-a, or PPa) and a black hole quencher-3 (BHQ3) through a complementary oligonucleotide sequence. Cells with and without MDMX high-expression are incubated with the beacon and then irradiated with a laser. The fluorescence and reactive oxygen species are detected in solution to verify the specific activation of PPa by the perfectly matched DNA targets. The cell viabilities are evaluated with CCK-8 and flow cytometry assay. The fluorescence and photo-cytoxicity of PPa is recovered and significantly higher in the MDMX high-expressed Y79 and WERI-Rb1 cells, compared to that with the MDMX low-expressed cells. The synthesized beacon exhibits high PDT efficiency toward MDMX high-expressed RB cells. The data suggest that the designed beacon may provide a potential alternative for RB therapy and secures the ground for future investigation.

  15. DNA aptamer beacon assay for C-telopeptide and handheld fluorometer to monitor bone resorption.

    PubMed

    Bruno, John Gordon; Carrillo, Maria P; Phillips, Taylor; Hanson, Douglas; Bohmann, Jonathan A

    2011-09-01

    A novel DNA aptamer beacon is described for quantification of a 26-amino acid C-telopeptide (CTx) of human type I bone collagen. One aptamer sequence and its reverse complement dominated the aptamer pool (31.6% of sequenced clones). Secondary structures of these aptamers were examined for potential binding pockets. Three-dimensional computer models which analyzed docking topologies and binding energies were in agreement with empirical fluorescence experiments used to select one candidate loop for beacon assay development. All loop structures from the aptamer finalists were end-labeled with TYE 665 and Iowa Black quencher for comparison of beacon fluorescence levels as a function of CTx concentration. The optimal beacon, designated CTx 2R-2h yielded a low ng/ml limit of detection using a commercially available handheld fluorometer. The CTx aptamer beacon bound full-length 26-amino acid CTx peptide, but not a shorter 8-amino acid segment of CTx peptide which is a common target for commercial CTx ELISA kits. The prototype assay was shown to detect CTx peptide from human urine after creatinine and urea were removed by size-exclusion chromatography to prevent nonspecific denaturing of the aptamer beacon. This work demonstrates the potential of aptamer beacons to be utilized for rapid and sensitive bone health monitoring in a handheld or point-of-care format.

  16. What Happened to the Beacon Schools? Policy Reform and Educational Equity

    ERIC Educational Resources Information Center

    Smith, Emma

    2015-01-01

    This paper considers the impact of the Beacon schools initiative on the social and academic characteristics of secondary schools in England. The Beacon schools programme ran from 1998 to 2004 and epitomised the (then) Labour government's focus on school improvement through diversity, collaboration and partnership. This paper looks at variation in…

  17. Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies

    PubMed Central

    Uhlemann, Elisabeth

    2018-01-01

    Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC) method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications. PMID:29570676

  18. Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies.

    PubMed

    Balador, Ali; Uhlemann, Elisabeth; Calafate, Carlos T; Cano, Juan-Carlos

    2018-03-23

    Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC) method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications.

  19. Beaconing Signalization Substantially Reduces Blind Pedestrians’ Veer on Snow-Covered Pavement

    PubMed Central

    Guth, David A.; Long, Richard G.; Kim, Dae Shik; Robertson, Elizabeth A.; Reesor, Abbie L.; Bacik, Catherine J.; Eckert, Jaclyn M.

    2017-01-01

    Veering outside of crosswalks is a common problem experienced by individuals who are blind. One technology found to be effective for reducing this veer when other guidance cues are absent is audible beaconing. However, veering in general and veering from crosswalks in particular have been studied primarily on smooth, flat walking surfaces such as clear pavement. This experiment compared veering on clear pavement with veering on snow-covered pavement, with and without audible beaconing. Eleven blind participants traveling with long canes attempted to walk a straight path for 72 ft (21.9 m), a typical length of a six-lane crosswalk. Beaconing substantially reduced veering at 36 ft (11.0 m) and 72 ft from the starting point and enabled participants to remain within a simulated crosswalk. Walking on snow was not found to affect veering but did increase the number of steps taken. The findings suggest that in snowy and clear conditions alike, audible beaconing is an effective wayfinding tool for intersections equipped with accessible pedestrian signals. PMID:29307955

  20. Beaconing Signalization Substantially Reduces Blind Pedestrians' Veer on Snow-Covered Pavement.

    PubMed

    Guth, David A; Long, Richard G; Kim, Dae Shik; Robertson, Elizabeth A; Reesor, Abbie L; Bacik, Catherine J; Eckert, Jaclyn M

    2017-01-01

    Veering outside of crosswalks is a common problem experienced by individuals who are blind. One technology found to be effective for reducing this veer when other guidance cues are absent is audible beaconing. However, veering in general and veering from crosswalks in particular have been studied primarily on smooth, flat walking surfaces such as clear pavement. This experiment compared veering on clear pavement with veering on snow-covered pavement, with and without audible beaconing. Eleven blind participants traveling with long canes attempted to walk a straight path for 72 ft (21.9 m), a typical length of a six-lane crosswalk. Beaconing substantially reduced veering at 36 ft (11.0 m) and 72 ft from the starting point and enabled participants to remain within a simulated crosswalk. Walking on snow was not found to affect veering but did increase the number of steps taken. The findings suggest that in snowy and clear conditions alike, audible beaconing is an effective wayfinding tool for intersections equipped with accessible pedestrian signals.

  1. An Adaptive Scheme for Robot Localization and Mapping with Dynamically Configurable Inter-Beacon Range Measurements

    PubMed Central

    Torres-González, Arturo; Martinez-de Dios, Jose Ramiro; Ollero, Anibal

    2014-01-01

    This work is motivated by robot-sensor network cooperation techniques where sensor nodes (beacons) are used as landmarks for range-only (RO) simultaneous localization and mapping (SLAM). This paper presents a RO-SLAM scheme that actuates over the measurement gathering process using mechanisms that dynamically modify the rate and variety of measurements that are integrated in the SLAM filter. It includes a measurement gathering module that can be configured to collect direct robot-beacon and inter-beacon measurements with different inter-beacon depth levels and at different rates. It also includes a supervision module that monitors the SLAM performance and dynamically selects the measurement gathering configuration balancing SLAM accuracy and resource consumption. The proposed scheme has been applied to an extended Kalman filter SLAM with auxiliary particle filters for beacon initialization (PF-EKF SLAM) and validated with experiments performed in the CONET Integrated Testbed. It achieved lower map and robot errors (34% and 14%, respectively) than traditional methods with a lower computational burden (16%) and similar beacon energy consumption. PMID:24776938

  2. An adaptive scheme for robot localization and mapping with dynamically configurable inter-beacon range measurements.

    PubMed

    Torres-González, Arturo; Martinez-de Dios, Jose Ramiro; Ollero, Anibal

    2014-04-25

    This work is motivated by robot-sensor network cooperation techniques where sensor nodes (beacons) are used as landmarks for range-only (RO) simultaneous localization and mapping (SLAM). This paper presents a RO-SLAM scheme that actuates over the measurement gathering process using mechanisms that dynamically modify the rate and variety of measurements that are integrated in the SLAM filter. It includes a measurement gathering module that can be configured to collect direct robot-beacon and inter-beacon measurements with different inter-beacon depth levels and at different rates. It also includes a supervision module that monitors the SLAM performance and dynamically selects the measurement gathering configuration balancing SLAM accuracy and resource consumption. The proposed scheme has been applied to an extended Kalman filter SLAM with auxiliary particle filters for beacon initialization (PF-EKF SLAM) and validated with experiments performed in the CONET Integrated Testbed. It achieved lower map and robot errors (34% and 14%, respectively) than traditional methods with a lower computational burden (16%) and similar beacon energy consumption.

  3. Preliminary performance analysis of an interplanetary navigation system using asteroid based beacons

    NASA Technical Reports Server (NTRS)

    Jee, J. Rodney; Khatib, Ahmad R.; Muellerschoen, Ronald J.; Williams, Bobby G.; Vincent, Mark A.

    1988-01-01

    A futuristic interplanetary navigation system using transmitters placed on selected asteroids is introduced. This network of space beacons is seen as a needed alternative to the overly burdened Deep Space Network. Covariance analyses on the potential performance of these space beacons located on a candidate constellation of eight real asteroids are initiated. Simplified analytic calculations are performed to determine limiting accuracies attainable with the network for geometric positioning. More sophisticated computer simulations are also performed to determine potential accuracies using long arcs of range and Doppler data from the beacons. The results from these computations show promise for this navigation system.

  4. Quencher-free molecular beacon tethering 7-hydroxycoumarin detects targets through protonation/deprotonation.

    PubMed

    Kashida, Hiromu; Yamaguchi, Kyohei; Hara, Yuichi; Asanuma, Hiroyuki

    2012-07-15

    In this study, we synthesized a simple but efficient quencher-free molecular beacon tethering 7-hydroxycoumarin on D-threoninol based on its pK(a) change. The pK(a) of 7-hydroxycoumarin in a single strand was determined as 8.8, whereas that intercalated in the duplex was over 10. This large pK(a) shift (more than 1.2) upon hybridization could be attributed to the anionic and hydrophobic microenvironment inside the DNA duplex. Because 7-hydroxycoumarin quenches its fluorescence upon protonation, the emission intensity of the duplex at pH 8.5 was 1/15 that of the single strand. We applied this quenching mechanism to the preparation of a quencher-free molecular beacon by introducing the dye into the middle of the stem part. In the absence of the target, the stem region formed a duplex and fluorescence was quenched. However, when the target was added, the molecular beacon opened and the dye was deprotonated. As a result, the emission intensity of the molecular beacon with the target was 10 times higher than that without the target. Accordingly, a quencher-free molecular beacon utilizing the pK(a) change was successfully developed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Highly sensitive and rapid bacteria detection using molecular beacon-Au nanoparticles hybrid nanoprobes.

    PubMed

    Cao, Jing; Feng, Chao; Liu, Yan; Wang, Shouyu; Liu, Fei

    2014-07-15

    Since many diseases are caused by pathogenic bacterial infections, accurate and rapid detection of pathogenic bacteria is in urgent need to timely apply appropriate treatments and to reduce economic costs. To end this, we designed molecular beacon-Au nanoparticle hybrid nanoprobes to improve the bacterial detection efficiency and sensitivity. Here, we show that the designed molecular beacon modified Au nanoparticles could specifically recognize synthetic DNAs targets and can readily detect targets in clinical samples. Moreover, the hybrid nanoprobes can recognize Escherichia coli within an hour at a concentration of 10(2) cfu/ml, which is 1000-folds sensitive than using molecular beacon directly. Our results show that the molecular beacon-Au nanoparticle hybrid nanoprobes have great potential in medical and biological applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Beacon- and Schema-Based Method for Recognizing Algorithms from Students' Source Code

    ERIC Educational Resources Information Center

    Taherkhani, Ahmad; Malmi, Lauri

    2013-01-01

    In this paper, we present a method for recognizing algorithms from students programming submissions coded in Java. The method is based on the concept of "programming schemas" and "beacons". Schemas are high-level programming knowledge with detailed knowledge abstracted out, and beacons are statements that imply specific…

  7. The First Year of Beacon School Status: Maintaining Excellence and Sharing Success.

    ERIC Educational Resources Information Center

    Burton, Neil; Brundrett, Mark

    2000-01-01

    During summer 1998, the British government's Department for Education and Employment recognized 74 schools as model "beacons of excellence." A recent survey reveals that effective communication, coupled with a clear sense of purpose and vision, has enabled Beacon schools to maintain educational excellence while facilitating other…

  8. Visual detection of multidrug resistance gene in living cell using the molecular beacon imaging

    NASA Astrophysics Data System (ADS)

    Zhou, Qiumei; Ma, Yi; Gu, Yueqing

    2014-09-01

    A major problem in cancer treatment is the development of resistance to chemotherapeutic agents in tumor cells. Detection of effective prognostic biomarkers and targets are of crucial importance to the management of individualized therapies. However, quantitative analysis of the drug resistance gene had been difficult because of technical limitations. In this study, we designed and used a special hairpin deoxyribonucleic acid (DNA), which served as a beacon for detecting human drug resistance indicater. Upon hybridizing with the target mRNA, the hairpin DNA modified gold nanoparticle beacons (hDAuNP beacons) release the fluorophores attached at 5'end of the oligonucleotide sequence. The fluorescence properties of the beacon before and after the hybridization with the complementary DNA were confirmed in vitro. The hDAuNP beacons could be taken up by living cells with low inherent cytotoxicity and higher stability. hDAuNP beacon imaged by confocal laser scanning microscopy to detect the resistance gene expression. The detected fluorescence in MCF7and MCF7/ADR cells correlates with the specific drug resistance gene expression, which is consistent with the result from Q-PCR. Thus, this approach overcame many of the challenges of previous techniques by creating highly sensitive and effective intracellular probes for monitoring gene expression.

  9. Impact of beacon wavelength on phase-compensation performance

    NASA Astrophysics Data System (ADS)

    Enterline, Allison A.; Spencer, Mark F.; Burrell, Derek J.; Brennan, Terry J.

    2017-09-01

    This study evaluates the effects of beacon-wavelength mismatch on phase-compensation performance. In general, beacon-wavelength mismatch occurs at the system level because the beacon-illuminator laser (BIL) and high-energy laser (HEL) are often at different wavelengths. Such is the case, for example, when using an aperture sharing element to isolate the beam-control sensor suite from the blinding nature of the HEL. With that said, this study uses the WavePlex Toolbox in MATLAB® to model ideal spherical wave propagation through various atmospheric-turbulence conditions. To quantify phase-compensation performance, we also model a nominal adaptive-optics (AO) system. We achieve correction from a Shack-Hartmann wavefront sensor and continuous-face-sheet deformable mirror using a least-squares phase reconstruction algorithm in the Fried geometry and a leaky integrator control law. To this end, we plot the power in the bucket metric as a function of BIL-HEL wavelength difference. Our initial results show that positive BIL-HEL wavelength differences achieve better phase compensation performance compared to negative BIL-HEL wavelength differences (i.e., red BILs outperform blue BILs). This outcome is consistent with past results.

  10. BBIS: Beacon Bus Information System

    NASA Astrophysics Data System (ADS)

    Kasim, Shahreen; Hafit, Hanayanti; Pei Juin, Kong; Afizah Afif, Zehan; Hashim, Rathiah; Ruslai, Husni; Jahidin, Kamaruzzaman; Syafwan Arshad, Mohammad

    2016-11-01

    Lack of bus information for example bus timetable, status of the bus and messy advertisement on bulletin board at the bus stop will give negative impact to tourist. Therefore, a real-time update bus information bulletin board provides all information needed so that passengers can save their bus information searching time. Supported with Android or iOS, Beacon Bus Information System (BBIS) provides bus information between Batu Pahat and Kluang area. BBIS is a system that implements physical web technology and interaction on demand. It built on Backend-as-a-Service, a cloud solution and Firebase non relational database as data persistence backend and syncs between user client in the real-time. People walk through bus stop with smart device and do not require any application. Bluetooth Beacon is used to achieve smart device's best performance of data sharing. Intellij IDEA 15 is one of the tools that that used to develop the BBIS system. Multi-language included front end and backend supported Integration development environment (IDE) helped to speed up integration process.

  11. Beacons of X-ray Light Animation

    NASA Image and Video Library

    2014-10-08

    This image shows a neutron star -- the core of a star that exploded in a massive supernova. This particular neutron star is known as a pulsar because it sends out rotating beams of X-rays that sweep past Earth like lighthouse beacons.

  12. Frequency Estimator Performance for a Software-Based Beacon Receiver

    NASA Technical Reports Server (NTRS)

    Zemba, Michael J.; Morse, Jacquelynne Rose; Nessel, James A.; Miranda, Felix

    2014-01-01

    As propagation terminals have evolved, their design has trended more toward a software-based approach that facilitates convenient adjustment and customization of the receiver algorithms. One potential improvement is the implementation of a frequency estimation algorithm, through which the primary frequency component of the received signal can be estimated with a much greater resolution than with a simple peak search of the FFT spectrum. To select an estimator for usage in a QV-band beacon receiver, analysis of six frequency estimators was conducted to characterize their effectiveness as they relate to beacon receiver design.

  13. Frequency Estimator Performance for a Software-Based Beacon Receiver

    NASA Technical Reports Server (NTRS)

    Zemba, Michael J.; Morse, Jacquelynne R.; Nessel, James A.

    2014-01-01

    As propagation terminals have evolved, their design has trended more toward a software-based approach that facilitates convenient adjustment and customization of the receiver algorithms. One potential improvement is the implementation of a frequency estimation algorithm, through which the primary frequency component of the received signal can be estimated with a much greater resolution than with a simple peak search of the FFT spectrum. To select an estimator for usage in a Q/V-band beacon receiver, analysis of six frequency estimators was conducted to characterize their effectiveness as they relate to beacon receiver design.

  14. Real-time monitoring of rolling-circle amplification using a modified molecular beacon design

    PubMed Central

    Nilsson, Mats; Gullberg, Mats; Dahl, Fredrik; Szuhai, Karoly; Raap, Anton K.

    2002-01-01

    We describe a method to monitor rolling-circle replication of circular oligonucleotides in dual-color and in real-time using molecular beacons. The method can be used to study the kinetics of the polymerization reaction and to amplify and quantify circularized oligonucleotide probes in a rolling-circle amplification (RCA) reaction. Modified molecular beacons were made of 2′-O-Me-RNA to prevent 3′ exonucleolytic degradation by the polymerase used. Moreover, the complement of one of the stem sequences of the molecular beacon was included in the RCA products to avoid fluorescence quenching due to inter-molecular hybridization of neighboring molecular beacons hybridizing to the concatemeric polymerization product. The method allows highly accurate quantification of circularized DNA over a broad concentration range by relating the signal from the test DNA circle to an internal reference DNA circle reporting in a distinct fluorescence color. PMID:12136114

  15. Aftermath of bustamante attack on genomic beacon service.

    PubMed

    Aziz, Md Momin Al; Ghasemi, Reza; Waliullah, Md; Mohammed, Noman

    2017-07-26

    With the enormous need for federated eco-system for holding global genomic and clinical data, Global Alliance for Genomic and Health (GA4GH) has created an international website called beacon service which allows a researcher to find out whether a specific dataset can be utilized to his or her research beforehand. This simple webservice is quite useful as it allows queries like whether a certain position of a target chromosome has a specific nucleotide. However, the increased integration of individuals genomic data into clinical practice and research raised serious privacy concern. Though the answer of such queries are yes or no in Bacon network, it results in serious privacy implication as demonstrated in a recent work from Shringarpure and Bustamante. In their attack model, the authors demonstrated that with a limited number of queries, presence of an individual in any dataset can be determined. We propose two lightweight algorithms (based on randomized response) which captures the efficacy while preserving the privacy of the participants in a genomic beacon service. We also elaborate the strength and weakness of the attack by explaining some of their statistical and mathematical models using real world genomic database. We extend their experimental simulations for different adversarial assumptions and parameters. We experimentally evaluated the solutions on the original attack model with different parameters for better understanding of the privacy and utility tradeoffs provided by these two methods. Also, the statistical analysis further elaborates the different aspects of the prior attack which leads to a better risk management for the participants in a beacon service. The differentially private and lightweight solutions discussed here will make the attack much difficult to succeed while maintaining the fundamental motivation of beacon database network.

  16. Road User Behaviors At Pedestrian Hybrid Beacons

    DOT National Transportation Integrated Search

    2016-06-01

    The pedestrian hybrid beacon (PHB) has shown great potential for improving pedestrian safety and driver yielding. However, questions remain regarding under what roadway conditions such as crossing distance (i.e., number of lanes) and posted speed ...

  17. Evaluation of the New York City Beacons. Summary of Phase I Findings.

    ERIC Educational Resources Information Center

    Warren, Constancia

    This report presents findings from Phase 1 of an evaluation of the New York City Beacons initiative, a model of school-community-family partnerships initiated in 1991. Beacons are community centers located in public schools, offering a range of activities and services to participants of all ages, before and after school, in the evenings, and on…

  18. The ANTARES optical beacon system

    NASA Astrophysics Data System (ADS)

    Ageron, M.; Aguilar, J. A.; Albert, A.; Ameli, F.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardellier-Desages, F.; Aslanides, E.; Aubert, J.-J.; Auer, R.; Barbarito, E.; Basa, S.; Battaglieri, M.; Becherini, Y.; Beltramelli, J.; Bertin, V.; Bigi, A.; Billault, M.; Blaes, R.; de Botton, N.; Bouwhuis, M. C.; Bradbury, S. M.; Bruijn, R.; Brunner, J.; Burgio, G. F.; Busto, J.; Cafagna, F.; Caillat, L.; Calzas, A.; Capone, A.; Caponetto, L.; Carmona, E.; Carr, J.; Cartwright, S. L.; Castel, D.; Castorina, E.; Cavasinni, V.; Cecchini, S.; Ceres, A.; Charvis, P.; Chauchot, P.; Chiarusi, T.; Circella, M.; Colnard, C.; Compère, C.; Coniglione, R.; Cottini, N.; Coyle, P.; Cuneo, S.; Cussatlegras, A.-S.; Damy, G.; van Dantzig, R.; de Bonis, G.; de Marzo, C.; de Vita, R.; Dekeyser, I.; Delagnes, E.; Denans, D.; Deschamps, A.; Destelle, J.-J.; Dinkespieler, B.; Distefano, C.; Donzaud, C.; Drogou, J.-F.; Druillole, F.; Durand, D.; Ernenwein, J.-P.; Escoffier, S.; Falchini, E.; Favard, S.; Fehr, F.; Feinstein, F.; Ferry, S.; Fiorello, C.; Flaminio, V.; Fratini, K.; Fuda, J.-L.; Galeotti, S.; Gallone, J.-M.; Giacomelli, G.; Girard, N.; Gojak, C.; Goret, Ph.; Graf, K.; Hallewell, G.; Harakeh, M. N.; Hartmann, B.; Heijboer, A.; Heine, E.; Hello, Y.; Hernández-Rey, J. J.; Hößl, J.; Hoffman, C.; Hogenbirk, J.; Hubbard, J. R.; Jaquet, M.; Jaspers, M.; de Jong, M.; Jouvenot, F.; Kalantar-Nayestanaki, N.; Kappes, A.; Karg, T.; Katz, U.; Keller, P.; Kok, E.; Kok, H.; Kooijman, P.; Kopper, C.; Korolkova, E. V.; Kouchner, A.; Kretschmer, W.; Kruijer, A.; Kuch, S.; Kudryavstev, V. A.; Lagier, P.; Lahmann, R.; Lamanna, G.; Lamare, P.; Lambard, G.; Languillat, J.-C.; Laschinsky, H.; Lavalle, J.; Le Guen, Y.; Le Provost, H.; Le van Suu, A.; Lefèvre, D.; Legou, T.; Lelaizant, G.; Lim, G.; Lo Presti, D.; Loehner, H.; Loucatos, S.; Louis, F.; Lucarelli, F.; Lyashuk, V.; Marcelin, M.; Margiotta, A.; Masullo, R.; Mazéas, F.; Mazure, A.; McMillan, J. E.; Megna, R.; Melissas, M.; Migneco, E.; Milovanovic, A.; Mongelli, M.; Montaruli, T.; Morganti, M.; Moscoso, L.; Musumeci, M.; Naumann-Godo, M.; Naumann, C.; Niess, V.; Noble, T.; Olivetto, C.; Ostasch, R.; Palanque-Delabrouille, N.; Payre, P.; Peek, H.; Perez, A.; Petta, C.; Piattelli, P.; Pillet, R.; Pineau, J.-P.; Poinsignon, J.; Popa, V.; Pradier, T.; Racca, C.; Randazzo, N.; van Randwijk, J.; Real, D.; van Rens, B.; Réthoré, F.; Rewiersma, P.; Riccobene, G.; Rigaud, V.; Ripani, M.; Roca, V.; Roda, C.; Rolin, J. F.; Rose, H. J.; Rostovtsev, A.; Roux, J.; Ruppi, M.; Russo, G. V.; Rusydi, G.; Salesa, F.; Salomon, K.; Sapienza, P.; Schmitt, F.; Schuller, J.-P.; Shanidze, R.; Sokalski, I.; Spona, T.; Spurio, M.; van der Steenhoven, G.; Stolarczyk, T.; Streeb, K.; Sulak, L.; Taiuti, M.; Tamburini, C.; Tao, C.; Terreni, G.; Thompson, L. F.; Urbano, F.; Valdy, P.; Valente, V.; Vallage, B.; Vaudaine, G.; Venekamp, G.; Verlaat, B.; Vernin, P.; de Vries-Uiterweerd, G.; van Wijk, R.; Wijnker, G.; de Witt Huberts, P.; Wobbe, G.; de Wolf, E.; Yao, A.-F.; Zaborov, D.; Zaccone, H.; Zornoza, J. D.; Zúñiga, J.

    2007-08-01

    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented.

  19. VHF-FM Emergency Position Indicating Radio Beacon

    DOT National Transportation Integrated Search

    1978-10-01

    This report describes the development and testing of an Emergency Position Indicating Radio Beacon (EPIRB) which operates on Channels 15 and 16 of the Maritime Mobile VHF Band. It provides functions necessary to ensure that distress alerting and loca...

  20. Beacon Spacecraft Operations: Lessons in Automation

    NASA Technical Reports Server (NTRS)

    Sherwood, R.; Schlutsmeyer, A.; Sue, M.; Szijjarto, J.; Wyatt, E. J.

    2000-01-01

    A new approach to mission operations has been flight validated on NASA's Deep Space One (DS1) mission that launched in October 1998. The beacon monitor operations technology is aimed at decreasing the total volume of downlinked engineering telemetry by reducing the frequency of downlink and the volume of data received per pass.

  1. 77 FR 41271 - Safety Zone; Newburgh to Beacon Swim, Newburgh, Hudson River, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... 1625-AA00 Safety Zone; Newburgh to Beacon Swim, Newburgh, Hudson River, NY AGENCY: Coast Guard, DHS... navigable waters of the Hudson River, NY in the vicinity of Newburgh, NY for the annual Newburgh Beacon Swim... hazards associated with swimmers competing in a swim across the Hudson River. Persons and vessels are...

  2. An Oasis in This Desert: Parents Talk about the New York City Beacons.

    ERIC Educational Resources Information Center

    Nevarez, Nancy

    This report presents the findings of focus groups convened to determine what the parents of youth participants in the New York City Beacons think about the program. The Beacons initiative is a comprehensive model of school-community-family partnerships undertaken by New York City in 1991. The initiative originally enabled 10 community-based…

  3. Chemically directing d-block heterometallics to nanocrystal surfaces as molecular beacons of surface structure

    DOE PAGES

    Rosen, Evelyn L.; Gilmore, Keith; Sawvel, April M.; ...

    2015-07-28

    Our understanding of structure and bonding in nanoscale materials is incomplete without knowledge of their surface structure. Needed are better surveying capabilities responsive not only to different atoms at the surface, but also their respective coordination environments. We report here that d-block organometallics, when placed at nanocrystal surfaces through heterometallic bonds, serve as molecular beacons broadcasting local surface structure in atomic detail. This unique ability stems from their elemental specificity and the sensitivity of their d-orbital level alignment to local coordination environment, which can be assessed spectroscopically. Re-surfacing cadmium and lead chalcogenide nanocrystals with iron- or ruthenium-based molecular beacons ismore » readily accomplished with trimethylsilylated cyclopentadienyl metal carbonyls. For PbSe nanocrystals with iron-based beacons, we show how core-level X-ray spectroscopies and DFT calculations enrich our understanding of both charge and atomic reorganization at the surface when beacons are bound.« less

  4. Building and strengthening infrastructure for data exchange: lessons from the beacon communities.

    PubMed

    Torres, Gretchen W; Swietek, Karen; Ubri, Petry S; Singer, Rachel F; Lowell, Kristina H; Miller, Wilhelmine

    2014-01-01

    The Beacon Community Cooperative Agreement Program supports interventions, including care-delivery innovations, provider performance measurement and feedback initiatives, and tools for providers and consumers to enhance care. Using a learning health system framework, we examine the Beacon Communities' processes in building and strengthening health IT (HIT) infrastructures, specifically successes and challenges in sharing patient information to improve clinical care. In 2010, the Office of the National Coordinator for Health Information Technology (ONC) launched the three-year program, which provided $250 million to 17 Beacon Communities to invest in HIT and health information exchange (HIE) infrastructure. Beacon Communities used this funding to develop and disseminate HIT-enabled quality improvement practices found effective in particular community and practice environments. NORC conducted 7 site visits, November 2012-March 2013, selecting Communities to represent diverse program features. From August-October 2013, NORC held discussions with the remaining 10 Communities. Following each visit or discussion, NORC summarized the information gathered, including transcripts, team observations, and other documents the Community provided, to facilitate a within-Community analysis of context and stakeholders, intervention strategies, enabling factors, and challenges. Although each Community designed and implemented data-sharing strategies in a unique environment, similar challenges and enabling factors emerged across the Beacons. From a learning health system perspective, their strategies to build and strengthen data-sharing infrastructures address the following crosscutting priorities: promoting technical advances and innovations by helping providers adapt EHRs for data exchange and performance measurement with customizable IT and offering technical support to smaller, independent providers; engaging key stakeholders; and fostering transparent governance and stewardship

  5. Building and Strengthening Infrastructure for Data Exchange: Lessons from the Beacon Communities

    PubMed Central

    Torres, Gretchen W.; Swietek, Karen; Ubri, Petry S.; Singer, Rachel F.; Lowell, Kristina H.; Miller, Wilhelmine

    2014-01-01

    Introduction: The Beacon Community Cooperative Agreement Program supports interventions, including care-delivery innovations, provider performance measurement and feedback initiatives, and tools for providers and consumers to enhance care. Using a learning health system framework, we examine the Beacon Communities’ processes in building and strengthening health IT (HIT) infrastructures, specifically successes and challenges in sharing patient information to improve clinical care. Background: In 2010, the Office of the National Coordinator for Health Information Technology (ONC) launched the three-year program, which provided $250 million to 17 Beacon Communities to invest in HIT and health information exchange (HIE) infrastructure. Beacon Communities used this funding to develop and disseminate HIT-enabled quality improvement practices found effective in particular community and practice environments. Methods: NORC conducted 7 site visits, November 2012–March 2013, selecting Communities to represent diverse program features. From August–October 2013, NORC held discussions with the remaining 10 Communities. Following each visit or discussion, NORC summarized the information gathered, including transcripts, team observations, and other documents the Community provided, to facilitate a within-Community analysis of context and stakeholders, intervention strategies, enabling factors, and challenges. Results: Although each Community designed and implemented data-sharing strategies in a unique environment, similar challenges and enabling factors emerged across the Beacons. From a learning health system perspective, their strategies to build and strengthen data-sharing infrastructures address the following crosscutting priorities: promoting technical advances and innovations by helping providers adapt EHRs for data exchange and performance measurement with customizable IT and offering technical support to smaller, independent providers; engaging key stakeholders; and

  6. The dependence of the anisoplanatic Strehl of a compensated beam on the beacon distribution

    NASA Astrophysics Data System (ADS)

    Stroud, P.

    1992-02-01

    There are several applications for lasers where the effect of atmospheric turbulence is strong enough to require wavefront compensation, and the compensation can be made by an adaptive optics (AO) system which processes light returned from the target itself. The distribution of the target return light produces limitations to the performance of the AO system. The primary intent of this documentation is to present the new results of an analysis of the anisoplanatic effects arising from target return beacon geometries. It will also lay out the assumptions and steps in the analysis, so that the results can be validated or extended. The intent is to provide a self-consistent notation, simple physical interpretations of the mathematical formulations, and enough detail to reduce the investment of time required to become acquainted or reacquainted with the physics of laser propagation through turbulence, at a level needed to analyze anisoplanatic effects. A general formulation has been developed to calculate the anisoplanatic Strehl of a compensated beam for any beacon distribution and turbulence profile. Numerical calculations are also shown for several beacon geometries and turbulence profiles. The key result is that the spread of the beacon distribution has a much less deleterious effect than does the offset of the beacon centroid from the aimpoint.

  7. Precise locating approach of the beacon based on gray gradient segmentation interpolation in satellite optical communications.

    PubMed

    Wang, Qiang; Liu, Yuefei; Chen, Yiqiang; Ma, Jing; Tan, Liying; Yu, Siyuan

    2017-03-01

    Accurate location computation for a beacon is an important factor of the reliability of satellite optical communications. However, location precision is generally limited by the resolution of CCD. How to improve the location precision of a beacon is an important and urgent issue. In this paper, we present two precise centroid computation methods for locating a beacon in satellite optical communications. First, in terms of its characteristics, the beacon is divided into several parts according to the gray gradients. Afterward, different numbers of interpolation points and different interpolation methods are applied in the interpolation area; we calculate the centroid position after interpolation and choose the best strategy according to the algorithm. The method is called a "gradient segmentation interpolation approach," or simply, a GSI (gradient segmentation interpolation) algorithm. To take full advantage of the pixels of the beacon's central portion, we also present an improved segmentation square weighting (SSW) algorithm, whose effectiveness is verified by the simulation experiment. Finally, an experiment is established to verify GSI and SSW algorithms. The results indicate that GSI and SSW algorithms can improve locating accuracy over that calculated by a traditional gray centroid method. These approaches help to greatly improve the location precision for a beacon in satellite optical communications.

  8. Magnetic resonance beacon to detect intracellular microRNA during neurogenesis.

    PubMed

    Lee, Jonghwan; Jin, Yeon A; Ko, Hae Young; Lee, Yong Seung; Heo, Hyejung; Cho, Sujeong; Kim, Soonhag

    2015-02-01

    Magnetic resonance imaging (MRI) offers great spatial resolution for viewing deep tissues and anatomy. We developed a self-assembling signal-on magnetic fluorescence nanoparticle to visualize intracellular microRNAs (miRNAs or miRs) during neurogenesis using MRI. The self-assembling nanoparticle (miR124a MR beacon) was aggregated by the incubation of three different oligonucleotides: a 3' adaptor, a 5' adaptor, and a linker containing miR124a-binding sequences. The T2-weighted magnetic resonance (MR) signal of the self-assembled nanoparticle was quenched when miR124a was absent from test tubes or was minimally expressed in cells and tissues. When miR124a was present in test tubes or highly expressed in vitro and in vivo during P19 cell neurogenesis, it hybridized with the miR124a MR beacon, causing the linker to detach, resulting in increased signal-on MRI intensity. This MR beacon can be used as a new imaging probe to monitor the miRNA-mediated regulation of cellular processes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  10. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  11. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  12. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  13. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  14. Dual Functional Roles of Molecular Beacon as a MicroRNA Detector and Inhibitor*

    PubMed Central

    Li, Wai Ming; Chan, Ching-Man; Miller, Andrew L.; Lee, Chow H.

    2017-01-01

    MicroRNAs are essential in many cellular processes. The ability to detect microRNAs is important for understanding its function and biogenesis. This study is aimed at using a molecular beacon to detect miR-430 in developing zebrafish embryos as a proof of principle. miR-430 is crucial for the clearance of maternal mRNA during maternal zygotic transition in embryonic development. Despite its known function, the temporal and spatial expression of miR-430 remains unclear. We used various imaging techniques, including laser scanning confocal microscopy, spinning disk, and lightsheet microscopy, to study the localization of miR-430 and any developmental defects possibly caused by the molecular beacon. Our results show that miR-430 is expressed early in development and is localized in distinct cytoplasmic granules where its target mRNA can be detected. We also show that the designed molecular beacon can inhibit the function of miR-430 and cause developmental defect in the brain, notochord, heart, and kidney, depending on the delivery site within the embryo, suggesting that miR-430 plays a diverse role in embryonic morphogenesis. When compared with morpholino, molecular beacon is 2 orders of magnitude more potent in inhibiting miR-430. Thus, our results reveal that in addition to being used as a valuable tool for the detection of microRNAs in vivo, molecular beacons can also be employed to inhibit microRNAs in a specific manner. PMID:28100783

  15. Theoretical analysis and experimental study of constraint boundary conditions for acquiring the beacon in satellite-ground laser communications

    NASA Astrophysics Data System (ADS)

    Yu, Siyuan; Wu, Feng; Wang, Qiang; Tan, Liying; Ma, Jing

    2017-11-01

    Acquisition and recognition for the beacon is the core technology of establishing the satellite optical link. In order to acquire the beacon correctly, the beacon image should be recognized firstly, excluding the influence of the background light. In this processing, many factors will influence the recognition precision of the beacon. This paper studies the constraint boundary conditions for acquiring the beacon from the perspective of theory and experiment, and as satellite-ground laser communications, an approach for obtaining the adaptive segmentation method is also proposed. Finally, the long distance laser communication experiment (11.16 km) verifies the validity of this method and the tracking error with the method is the least compared with the traditional approaches. The method helps to greatly improve the tracking precision in the satellite-ground laser communications.

  16. 76 FR 65216 - Beacon Medical Services, LLC, Aurora, CO; Notice of Negative Determination Regarding Application...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-20

    ... application received July 25, 2011, a worker requested administrative reconsideration of the negative determination regarding workers' eligibility to apply for Trade Adjustment Assistance (TAA) applicable to workers and former workers of Beacon Medical Services, LLC, Aurora, Colorado (Beacon Medical Services...

  17. Fusing Range Measurements from Ultrasonic Beacons and a Laser Range Finder for Localization of a Mobile Robot

    PubMed Central

    Ko, Nak Yong; Kuc, Tae-Yong

    2015-01-01

    This paper proposes a method for mobile robot localization in a partially unknown indoor environment. The method fuses two types of range measurements: the range from the robot to the beacons measured by ultrasonic sensors and the range from the robot to the walls surrounding the robot measured by a laser range finder (LRF). For the fusion, the unscented Kalman filter (UKF) is utilized. Because finding the Jacobian matrix is not feasible for range measurement using an LRF, UKF has an advantage in this situation over the extended KF. The locations of the beacons and range data from the beacons are available, whereas the correspondence of the range data to the beacon is not given. Therefore, the proposed method also deals with the problem of data association to determine which beacon corresponds to the given range data. The proposed approach is evaluated using different sets of design parameter values and is compared with the method that uses only an LRF or ultrasonic beacons. Comparative analysis shows that even though ultrasonic beacons are sparsely populated, have a large error and have a slow update rate, they improve the localization performance when fused with the LRF measurement. In addition, proper adjustment of the UKF design parameters is crucial for full utilization of the UKF approach for sensor fusion. This study contributes to the derivation of a UKF-based design methodology to fuse two exteroceptive measurements that are complementary to each other in localization. PMID:25970259

  18. Development of satellite position location system for aircraft and boat distress beacons

    NASA Technical Reports Server (NTRS)

    Kahle, D. R.

    1982-01-01

    An international satellite system for the detection and location of distress beacons carried on aircraft and vessels is in its technical checkout phase. User demonstration and evaluation (D&E) will start in early 1983 and continue for two years. The D&E phase and a subsequent transition period will form the basis for improved search and rescue operations for the 1980's and beyond. The system, called COSPAS/SARSAT, has international participation involving the U.S., Canada, and France as SARSAT members and joint participation with the Soviet Union's COSPAS Project. Norway and the U.K. have recently joined as investigators. Average position location error of the satellite aided processing is expected to be from 10-20KM for the existing 121.5/243 MHz distress beacons and from 2-5KM for experimental beacons transmitting in the 406 MHz band.

  19. Evaluation of light-emitting diode beacon light fixtures.

    DOT National Transportation Integrated Search

    2009-12-01

    Rotating beacons containing filament light sources have long been used on highway maintenance trucks : to indicate the presence of the truck to other drivers. Because of advances in light-emitting diode (LED) : technologies, flashing lights containin...

  20. a Search for New Physics with the Beacon Mission

    NASA Astrophysics Data System (ADS)

    Turyshev, Slava G.; Shao, Michael; Girerd, André; Lane, Benjamin

    The primary objective of the Beyond Einstein Advanced Coherent Optical Network (BEACON) mission is a search for new physics beyond general relativity by measuring the curvature of relativistic space-time around the Earth. This curvature is characterized by the Eddington parameter γ — the most fundamental relativistic gravity parameter and a direct measure for the presence of new physical interactions. BEACON will achieve an accuracy of 1 × 10-9 in measuring the parameter γ, thereby going a factor of 30,000 beyond the present best result involving the Cassini spacecraft. Secondary mission objectives include: (i) a direct measurement of the "frame-dragging" and geodetic precessions in the Earth's rotational gravitomagnetic field, to 0.05% and 0.03% accuracy respectively, (ii) the first measurement of gravity's nonlinear effects on light and the corresponding second order spatial metric's effects to 0.01% accuracy. BEACON will lead to robust advances in tests of fundamental physics — this mission could discover a violation or extension of general relativity and/or reveal the presence of an additional long range interaction in physics. It will provide crucial information to separate modern scalar-tensor theories of gravity from general relativity, probe possible ways for gravity quantization, and test modern theories of cosmological evolution.

  1. Serum inverts and improves the fluorescence response of an aptamer beacon to various vitamin D analytes.

    PubMed

    Bruno, John G; Carrillo, Maria P; Phillips, Taylor; Edge, Allison

    2012-01-01

    A dominant aptamer loop structure from a library of nearly 100 candidate aptamer sequences developed against immobilized 25-hydroxyvitamin D(3) (calcidiol) was converted into a 5'-TYE 665 and 3'-Iowa black-labelled aptamer beacon. The aptamer beacon exhibited a mild 'lights on' reaction in buffer as a function of increasing concentrations of several vitamin D analogues and metabolites, with a limit of detection of approximately 200 ng/mL, and was not specific for any particular congener. In 10% or 50% human serum, the same aptamer beacon inverted its fluorescence behaviour to become a more intense 'lights off' reaction with an improved limit of detection in the range 4-16 ng/mL. We hypothesized that this drastic change in fluorescence behaviour was due to the presence of creatinine and urea in serum, which might destabilize the quenched beacon, causing an increase in fluorescence followed by decreasing fluorescence as a function of vitamin D concentrations that may bind and quench increasingly greater fractions of the denatured beacons. However, the results of several control experiments in the presence of physiological or greater concentrations of creatinine and urea, alone or combined in buffer, failed to produce the beacon fluorescence inversion. Other possible mechanistic hypotheses are also discussed. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Cleavable DNA-protein hybrid molecular beacon: A novel efficient signal translator for sensitive fluorescence anisotropy bioassay.

    PubMed

    Hu, Pan; Yang, Bin

    2016-01-15

    Due to its unique features such as high sensitivity, homogeneous format, and independence on fluorescent intensity, fluorescence anisotropy (FA) assay has become a hotspot of study in oligonucleotide-based bioassays. However, until now most FA probes require carefully customized structure designs, and thus are neither generalizable for different sensing systems nor effective to obtain sufficient signal response. To address this issue, a cleavable DNA-protein hybrid molecular beacon was successfully engineered for signal amplified FA bioassay, via combining the unique stable structure of molecular beacon and the large molecular mass of streptavidin. Compared with single DNA strand probe or conventional molecular beacon, the DNA-protein hybrid molecular beacon exhibited a much higher FA value, which was potential to obtain high signal-background ratio in sensing process. As proof-of-principle, this novel DNA-protein hybrid molecular beacon was further applied for FA bioassay using DNAzyme-Pb(2+) as a model sensing system. This FA assay approach could selectively detect as low as 0.5nM Pb(2+) in buffer solution, and also be successful for real samples analysis with good recovery values. Compatible with most of oligonucleotide probes' designs and enzyme-based signal amplification strategies, the molecular beacon can serve as a novel signal translator to expand the application prospect of FA technology in various bioassays. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Improved fixation quality provided by a Bessel beacon in an adaptive optics system.

    PubMed

    Lambert, Andrew J; Daly, Elizabeth M; Dainty, Christopher J

    2013-07-01

    We investigate whether a structured probe beam that creates the beacon for use in a retinal imaging adaptive optics system can provide useful side effects. In particular we investigate whether a Bessel beam that is seen by the subject as a set of concentric rings has a dampening effect on fixation variations of the subject under observation. This calming effect would allow longer periods of observation, particularly for patients with abnormal fixation. An experimental adaptive optics system developed for retinal imaging is used to monitor the fluctuations in aberrations for artificial and human subjects. The probe beam is alternated between a traditional beacon and one provided by a Bessel beam created by SLM. Time-frequency analysis is used to indicate the differences in power and time variation during fixation depending on whether the Bessel beam or the traditional beacon is employed. Comparison is made with the response for an artificial eye to discount systemic variations. Significant evidence is accrued to indicate the reduced fluctuations in fixation when the Bessel beam is employed to create the beacon. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  4. Pedestrian hybrid beacon guide : recommendations and case study.

    DOT National Transportation Integrated Search

    2014-01-01

    A pedestrian hybrid beacon (PHB) is a traffic control : device similar to a European pedestrian signal : (PELICAN) that was imported to the US and adapted by : engineers in Arizona to increase motorists awareness of : pedestrian crossings at uncon...

  5. Simulation of the air traffic control radar beacon system (soar) with application to a discrete address beacon system volume II: appendixes

    DOT National Transportation Integrated Search

    1975-04-01

    The report describes a computer simulation of the Air Traffic Control Radar Beacon System (ATCRBS). Operating on real air traffic data and actual characteristics of the relevant ground interrogators, the FORTRAN program re-enacts system operation in ...

  6. Simulation of the Air Traffic Control Radar Beacon System (SOAR) with application to a Discrete Address Beacon System. Volume 1 : text

    DOT National Transportation Integrated Search

    1975-04-01

    The report describes a computer simulation of the Air Traffic Control Radar Beacon System (ATCRBS). Operating on real air traffic data and actual characteristics of the relevant ground interrogators, the FORTRAN program re-enacts system operation in ...

  7. Double-hairpin molecular-beacon-based amplification detection for gene diagnosis linked to cancer.

    PubMed

    Xu, Huo; Zhang, Rongbo; Li, Feng; Zhou, Yingying; Peng, Ting; Wang, Xuedong; Shen, Zhifa

    2016-09-01

    A powerful double-hairpin molecular beacon (DHMB) was developed for cancer-related KRAS gene detection based on the one-to-two stoichiometry. During target DNA detection, DHMB can execute signal transduction even if no any exogenous element is involved. Unlike the conventional molecular beacon based on the one-to-one interaction, one target DNA not only hybridizes with one DHMB and opens its hairpin but also promotes the interaction between two DHMBs, causing the separation of two fluorophores from quenchers. This leads to an enhanced fluorescence signal. As a result, the target KRAS gene is able to be detected within a wide dynamic range from 0.05 to 200 nM with the detection limit of 50 pM, indicating a dramatic improvement compared with traditional molecular beacons. Moreover, the point mutations existing in target DNAs can be easily screened. The potential application for target species in real samples was indicated by the analysis of PCR amplicons of DNAs from the DNA extracted from SW620 cell. Besides becoming a promising candidate probe for molecular biology research and clinical diagnosis of genetic diseases, the DHMB is expected to provide a significant insight into the design of DNA probe-based homogenous sensing systems. Graphical Abstract A powerful double-hairpin molecular beacon (DHMB) was developed for cancer-related gene KRAS detection based on the one-to-two stoichiometry. Without the help of any exogenous probe, the point mutation is easily screened, and the target DNA can be quantified down to 50 pM, indicating a dramatic improvement compared with traditional molecular beacons.

  8. Dual Functional Roles of Molecular Beacon as a MicroRNA Detector and Inhibitor.

    PubMed

    Li, Wai Ming; Chan, Ching-Man; Miller, Andrew L; Lee, Chow H

    2017-03-03

    MicroRNAs are essential in many cellular processes. The ability to detect microRNAs is important for understanding its function and biogenesis. This study is aimed at using a molecular beacon to detect miR-430 in developing zebrafish embryos as a proof of principle. miR-430 is crucial for the clearance of maternal mRNA during maternal zygotic transition in embryonic development. Despite its known function, the temporal and spatial expression of miR-430 remains unclear. We used various imaging techniques, including laser scanning confocal microscopy, spinning disk, and lightsheet microscopy, to study the localization of miR-430 and any developmental defects possibly caused by the molecular beacon. Our results show that miR-430 is expressed early in development and is localized in distinct cytoplasmic granules where its target mRNA can be detected. We also show that the designed molecular beacon can inhibit the function of miR-430 and cause developmental defect in the brain, notochord, heart, and kidney, depending on the delivery site within the embryo, suggesting that miR-430 plays a diverse role in embryonic morphogenesis. When compared with morpholino, molecular beacon is 2 orders of magnitude more potent in inhibiting miR-430. Thus, our results reveal that in addition to being used as a valuable tool for the detection of microRNAs in vivo , molecular beacons can also be employed to inhibit microRNAs in a specific manner. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  9. Time-Resolved Nucleic Acid Hybridization Beacons Utilizing Unimolecular and Toehold-Mediated Strand Displacement Designs.

    PubMed

    Massey, Melissa; Ancona, Mario G; Medintz, Igor L; Algar, W Russ

    2015-12-01

    Nucleic acid hybridization probes are sought after for numerous assay and imaging applications. These probes are often limited by the properties of fluorescent dyes, prompting the development of new probes where dyes are paired with novel or nontraditional luminescent materials. Luminescent terbium complexes are an example of such a material, and these complexes offer several unique spectroscopic advantages. Here, we demonstrate two nonstem-loop designs for light-up nucleic acid hybridization beacons that utilize time-resolved Förster resonance energy transfer (TR-FRET) between a luminescent Lumi4-Tb cryptate (Tb) donor and a fluorescent reporter dye, where time-resolved emission from the dye provides an analytical signal. Both designs are based on probe oligonucleotides that are labeled at their opposite termini with Tb and a fluorescent reporter dye. In one design, a probe is partially blocked with a quencher dye-labeled oligonucleotide, and target hybridization is signaled through toehold-mediated strand displacement and loss of a competitive FRET pathway. In the other design, the intrinsic folding properties of an unblocked probe are utilized in combination with a temporal mechanism for signaling target hybridization. This temporal mechanism is based on a recently elucidated "sweet spot" for TR-FRET measurements and exploits distance control over FRET efficiencies to shift the Tb lifetime within or outside the time-gated detection window for measurements. Both the blocked and unblocked beacons offer nanomolar (femtomole) detection limits, response times on the order of minutes, multiplexing through the use of different reporter dyes, and detection in complex matrices such as serum and blood. The blocked beacons offer better mismatch selectivity, whereas the unblocked beacons are simpler in design. The temporal mechanism of signaling utilized with the unblocked beacons also plays a significant role with the blocked beacons and represents a new and effective

  10. MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardcastle, N; Booth, J; Caillet, V

    Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has beenmore » used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research

  11. A beacon interval shifting scheme for interference mitigation in body area networks.

    PubMed

    Kim, Seungku; Kim, Seokhwan; Kim, Jin-Woo; Eom, Doo-Seop

    2012-01-01

    This paper investigates the issue of interference avoidance in body area networks (BANs). IEEE 802.15 Task Group 6 presented several schemes to reduce such interference, but these schemes are still not proper solutions for BANs. We present a novel distributed TDMA-based beacon interval shifting scheme that reduces interference in the BANs. A design goal of the scheme is to avoid the wakeup period of each BAN coinciding with other networks by employing carrier sensing before a beacon transmission. We analyze the beacon interval shifting scheme and investigate the proper back-off length when the channel is busy. We compare the performance of the proposed scheme with the schemes presented in IEEE 802.15 Task Group 6 using an OMNeT++ simulation. The simulation results show that the proposed scheme has a lower packet loss, energy consumption, and delivery-latency than the schemes of IEEE 802.15 Task Group 6.

  12. Beacon Editor: Capturing Signal Transduction Pathways Using the Systems Biology Graphical Notation Activity Flow Language.

    PubMed

    Elmarakeby, Haitham; Arefiyan, Mostafa; Myers, Elijah; Li, Song; Grene, Ruth; Heath, Lenwood S

    2017-12-01

    The Beacon Editor is a cross-platform desktop application for the creation and modification of signal transduction pathways using the Systems Biology Graphical Notation Activity Flow (SBGN-AF) language. Prompted by biologists' requests for enhancements, the Beacon Editor includes numerous powerful features for the benefit of creation and presentation.

  13. A Beacon Interval Shifting Scheme for Interference Mitigation in Body Area Networks

    PubMed Central

    Kim, Seungku; Kim, Seokhwan; Kim, Jin-Woo; Eom, Doo-Seop

    2012-01-01

    This paper investigates the issue of interference avoidance in body area networks (BANs). IEEE 802.15 Task Group 6 presented several schemes to reduce such interference, but these schemes are still not proper solutions for BANs. We present a novel distributed TDMA-based beacon interval shifting scheme that reduces interference in the BANs. A design goal of the scheme is to avoid the wakeup period of each BAN coinciding with other networks by employing carrier sensing before a beacon transmission. We analyze the beacon interval shifting scheme and investigate the proper back-off length when the channel is busy. We compare the performance of the proposed scheme with the schemes presented in IEEE 802.15 Task Group 6 using an OMNeT++ simulation. The simulation results show that the proposed scheme has a lower packet loss, energy consumption, and delivery-latency than the schemes of IEEE 802.15 Task Group 6. PMID:23112639

  14. Low cost high efficiency GaAs monolithic RF module for SARSAT distress beacons

    NASA Technical Reports Server (NTRS)

    Petersen, W. C.; Siu, D. P.; Cook, H. F.

    1991-01-01

    Low cost high performance (5 Watts output) 406 MHz beacons are urgently needed to realize the maximum utilization of the Search and Rescue Satellite-Aided Tracking (SARSAT) system spearheaded in the U.S. by NASA. Although current technology can produce beacons meeting the output power requirement, power consumption is high due to the low efficiency of available transmitters. Field performance is currently unsatisfactory due to the lack of safe and reliable high density batteries capable of operation at -40 C. Low cost production is also a crucial but elusive requirement for the ultimate wide scale utilization of this system. Microwave Monolithics Incorporated (MMInc.) has proposed to make both the technical and cost goals for the SARSAT beacon attainable by developing a monolithic GaAs chip set for the RF module. This chip set consists of a high efficiency power amplifier and a bi-phase modulator. In addition to implementing the RF module in Monolithic Microwave Integrated Circuit (MMIC) form to minimize ultimate production costs, the power amplifier has a power-added efficiency nearly twice that attained with current commercial technology. A distress beacon built using this RF module chip set will be significantly smaller in size and lighter in weight due to a smaller battery requirement, since the 406 MHz signal source and the digital controller have far lower power consumption compared to the 5 watt power amplifier. All the program tasks have been successfully completed. The GaAs MMIC RF module chip set has been designed to be compatible with the present 406 MHz signal source and digital controller. A complete high performance low cost SARSAT beacon can be realized with only additional minor iteration and systems integration.

  15. Sequential strand displacement beacon for detection of DNA coverage on functionalized gold nanoparticles.

    PubMed

    Paliwoda, Rebecca E; Li, Feng; Reid, Michael S; Lin, Yanwen; Le, X Chris

    2014-06-17

    Functionalizing nanomaterials for diverse analytical, biomedical, and therapeutic applications requires determination of surface coverage (or density) of DNA on nanomaterials. We describe a sequential strand displacement beacon assay that is able to quantify specific DNA sequences conjugated or coconjugated onto gold nanoparticles (AuNPs). Unlike the conventional fluorescence assay that requires the target DNA to be fluorescently labeled, the sequential strand displacement beacon method is able to quantify multiple unlabeled DNA oligonucleotides using a single (universal) strand displacement beacon. This unique feature is achieved by introducing two short unlabeled DNA probes for each specific DNA sequence and by performing sequential DNA strand displacement reactions. Varying the relative amounts of the specific DNA sequences and spacing DNA sequences during their coconjugation onto AuNPs results in different densities of the specific DNA on AuNP, ranging from 90 to 230 DNA molecules per AuNP. Results obtained from our sequential strand displacement beacon assay are consistent with those obtained from the conventional fluorescence assays. However, labeling of DNA with some fluorescent dyes, e.g., tetramethylrhodamine, alters DNA density on AuNP. The strand displacement strategy overcomes this problem by obviating direct labeling of the target DNA. This method has broad potential to facilitate more efficient design and characterization of novel multifunctional materials for diverse applications.

  16. Portable-Beacon Landing System for Helicopters

    NASA Technical Reports Server (NTRS)

    Davis, Thomas J.; Clary, George R.; Chisholm, John P.; Macdonald, Stanley L.

    1987-01-01

    Prototype beacon landing system (BLS) allows helicopters to make precise landings in all weather. BLS easily added to existing helicopter avionic equipment and readily deployed at remote sites. Small and light, system employs X-band radar and digital processing. Variety of beams pulsed sequentially by ground station after initial interrogation by weather radar of approaching helicopter. Airborne microprocessor processes pulses to determine glide slope, course deviation, and range.

  17. Impacts of Fog Characteristics, Forward Illumination, and Warning Beacon Intensity Distribution on Roadway Hazard Visibility

    PubMed Central

    2016-01-01

    Warning beacons are critical for the safety of transportation, construction, and utility workers. These devices need to produce sufficient luminous intensity to be visible without creating glare to drivers. Published standards for the photometric performance of warning beacons do not address their performance in conditions of reduced visibility such as fog. Under such conditions light emitted in directions other than toward approaching drivers can create scattered light that makes workers and other hazards less visible. Simulations of visibility of hazards under varying conditions of fog density, forward vehicle lighting, warning beacon luminous intensity, and intensity distribution were performed to assess their impacts on visual performance by drivers. Each of these factors can influence the ability of drivers to detect and identify workers and hazards along the roadway in work zones. Based on the results, it would be reasonable to specify maximum limits on the luminous intensity of warning beacons in directions that are unlikely to be seen by drivers along the roadway, limits which are not included in published performance specifications. PMID:27314058

  18. Visual detection of STAT5B gene expression in living cell using the hairpin DNA modified gold nanoparticle beacon.

    PubMed

    Xue, Jianpeng; Shan, Lingling; Chen, Haiyan; Li, Yang; Zhu, Hongyan; Deng, Dawei; Qian, Zhiyu; Achilefu, Samuel; Gu, Yueqing

    2013-03-15

    Signal transducer and activator of transcription 5B (STAT5B) is an important protein in JAK-STAT signaling pathway that is responsible for the metastasis and proliferation of tumor cells. Determination of the STAT5B messenger Ribonucleic Acid (mRNA) relating to the STAT5B expression provides insight into the mechanism of tumor progression. In this study, we designed and used a special hairpin deoxyribonucleic acid (DNA) for human STAT5B mRNA to functionalize gold nanoparticles, which served as a beacon for detecting human STAT5B expression. Up to 90% quenching efficiency was achieved. Upon hybridizing with the target mRNA, the hairpin DNA modified gold nanoparticle beacons (hDAuNP beacons) release the fluorophores attached at 5' end of the oligonucleotide sequence. The fluorescence properties of the beacon before and after the hybridization with the complementary DNA were confirmed in vitro. The stability of hDAuNP beacons against degradation by DNase I and GSH indicated that the prepared beacon is stable inside cells. The detected fluorescence in MCF-7 cancer cells correlates with the specific STAT5B mRNA expression, which is consistent with the result from PCR measurement. Fluorescence microscopy showed that the hDAuNP beacons internalized in cells without using transfection agents, with intracellular distribution in the cytoplasm rather than the nucleus. The results demonstrated that this beacon could directly provide quantitative measurement of the intracellular STAT5B mRNA in living cells. Compared to the previous approaches, this beacon has advantages of higher target to background ratio of detection and an increased resistance to nuclease degradation. The strategy reported in this study is a promising approach for the intracellular measurement of RNA or protein expression in living cells, and has great potential in the study of drug screening and discovery. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. GaAs monolithic RF modules for SARSAT distress beacons

    NASA Technical Reports Server (NTRS)

    Cauley, Michael A.

    1991-01-01

    Monolithic GaAs UHF components for use in SARSAT Emergency Distress beacons are under development by Microwave Monolithics, Inc., Simi Valley, CA. The components include a bi-phase modulator, driver amplifier, and a 5 watt power amplifier.

  20. Analyte-Triggered DNA-Probe Release from a Triplex Molecular Beacon for Nanopore Sensing.

    PubMed

    Guo, Bingyuan; Sheng, Yingying; Zhou, Ke; Liu, Quansheng; Liu, Lei; Wu, Hai-Chen

    2018-03-26

    A new nanopore sensing strategy based on triplex molecular beacon was developed for the detection of specific DNA or multivalent proteins. The sensor is composed of a triplex-forming molecular beacon and a stem-forming DNA component that is modified with a host-guest complex. Upon target DNA hybridizing with the molecular beacon loop or multivalent proteins binding to the recognition elements on the stem, the DNA probe is released and produces highly characteristic current signals when translocated through α-hemolysin. The frequency of current signatures can be used to quantify the concentrations of the target molecules. This sensing approach provides a simple, quick, and modular tool for the detection of specific macromolecules with high sensitivity and excellent selectivity. It may find useful applications in point-of-care diagnostics with a portable nanopore kit in the future. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Increased dose near the skin due to electromagnetic surface beacon transponder.

    PubMed

    Ahn, Kang-Hyun; Manger, Ryan; Halpern, Howard J; Aydogan, Bulent

    2015-05-08

    The purpose of this study was to evaluate the increased dose near the skin from an electromagnetic surface beacon transponder, which is used for localization and tracking organ motion. The bolus effect due to the copper coil surface beacon was evaluated with radiographic film measurements and Monte Carlo simulations. Various beam incidence angles were evaluated for both 6 MV and 18 MV experimentally. We performed simulations using a general-purpose Monte Carlo code MCNPX (Monte Carlo N-Particle) to supplement the experimental data. We modeled the surface beacon geometry using the actual mass of the glass vial and copper coil placed in its L-shaped polyethylene terephthalate tubing casing. Film dosimetry measured factors of 2.2 and 3.0 enhancement in the surface dose for normally incident 6 MV and 18 MV beams, respectively. Although surface dose further increased with incidence angle, the relative contribution from the bolus effect was reduced at the oblique incidence. The enhancement factors were 1.5 and 1.8 for 6 MV and 18 MV, respectively, at an incidence angle of 60°. Monte Carlo simulation confirmed the experimental results and indicated that the epidermal skin dose can reach approximately 50% of the dose at dmax at normal incidence. The overall effect could be acceptable considering the skin dose enhancement is confined to a small area (~ 1 cm2), and can be further reduced by using an opposite beam technique. Further clinical studies are justified in order to study the dosimetric benefit versus possible cosmetic effects of the surface beacon. One such clinical situation would be intact breast radiation therapy, especially large-breasted women.

  2. Promoting Health in Hospitals: The Role of Beacon

    ERIC Educational Resources Information Center

    Whitelaw, Sandy; Watson, Jonathan; Hennessy, Sue

    2004-01-01

    "Best practice" is currently being used to enable modernisation within the National Health Service (NHS) in the United Kingdom. One element of this is the Beacon programme where examples of hospitals that exemplify local "best practice" are supported to develop and disseminate learning across the wider NHS. The aims of this…

  3. MicroRNA Detection Using a Double Molecular Beacon Approach: Distinguishing Between miRNA and Pre-miRNA.

    PubMed

    James, Amanda Marie; Baker, Meredith B; Bao, Gang; Searles, Charles D

    2017-01-01

    MicroRNAs (miRNAs) are small, noncoding RNAs that post-transcriptionally regulate gene expression and are recognized for their roles both as modulators of disease progression and as biomarkers of disease activity, including neurological diseases, cancer, and cardiovascular disease (CVD). Commonly, miRNA abundance is assessed using quantitative real-time PCR (qRT-PCR), however, qRT-PCR for miRNA can be labor intensive, time consuming, and may lack specificity for detection of mature versus precursor forms of miRNA. Here, we describe a novel double molecular beacon approach to miRNA assessment that can distinguish and quantify mature versus precursor forms of miRNA in a single assay, an essential feature for use of miRNAs as biomarkers for disease. Using this approach, we found that molecular beacons with DNA or combined locked nucleic acid (LNA)-DNA backbones can detect mature and precursor miRNAs (pre-miRNAs) of low (< 1 nM) abundance in vitro . The double molecular beacon assay was accurate in assessing miRNA abundance in a sample containing a mixed population of mature and precursor miRNAs. In contrast, qRT-PCR and the single molecular beacon assay overestimated miRNA abundance. Additionally, the double molecular beacon assay was less labor intensive than traditional qRT-PCR and had 10-25% increased specificity. Our data suggest that the double molecular beacon-based approach is more precise and specific than previous methods, and has the promise of being the standard for assessing miRNA levels in biological samples.

  4. MicroRNA Detection Using a Double Molecular Beacon Approach: Distinguishing Between miRNA and Pre-miRNA

    PubMed Central

    James, Amanda Marie; Baker, Meredith B.; Bao, Gang; Searles, Charles D.

    2017-01-01

    MicroRNAs (miRNAs) are small, noncoding RNAs that post-transcriptionally regulate gene expression and are recognized for their roles both as modulators of disease progression and as biomarkers of disease activity, including neurological diseases, cancer, and cardiovascular disease (CVD). Commonly, miRNA abundance is assessed using quantitative real-time PCR (qRT-PCR), however, qRT-PCR for miRNA can be labor intensive, time consuming, and may lack specificity for detection of mature versus precursor forms of miRNA. Here, we describe a novel double molecular beacon approach to miRNA assessment that can distinguish and quantify mature versus precursor forms of miRNA in a single assay, an essential feature for use of miRNAs as biomarkers for disease. Using this approach, we found that molecular beacons with DNA or combined locked nucleic acid (LNA)-DNA backbones can detect mature and precursor miRNAs (pre-miRNAs) of low (< 1 nM) abundance in vitro. The double molecular beacon assay was accurate in assessing miRNA abundance in a sample containing a mixed population of mature and precursor miRNAs. In contrast, qRT-PCR and the single molecular beacon assay overestimated miRNA abundance. Additionally, the double molecular beacon assay was less labor intensive than traditional qRT-PCR and had 10-25% increased specificity. Our data suggest that the double molecular beacon-based approach is more precise and specific than previous methods, and has the promise of being the standard for assessing miRNA levels in biological samples. PMID:28255356

  5. Design and Practical Evaluation of a Family of Lightweight Protocols for Heterogeneous Sensing through BLE Beacons in IoT Telemetry Applications.

    PubMed

    Hernández-Rojas, Dixys L; Fernández-Caramés, Tiago M; Fraga-Lamas, Paula; Escudero, Carlos J

    2017-12-27

    The Internet of Things (IoT) involves a wide variety of heterogeneous technologies and resource-constrained devices that interact with each other. Due to such constraints, IoT devices usually require lightweight protocols that optimize the use of resources and energy consumption. Among the different commercial IoT devices, Bluetooth and Bluetooth Low Energy (BLE)-based beacons, which broadcast periodically certain data packets to notify their presence, have experienced a remarkable growth, specially due to their application in indoor positioning systems. This article proposes a family of protocols named Lightweight Protocol for Sensors (LP4S) that provides fast responses and enables plug-and-play mechanisms that allow IoT telemetry systems to discover new nodes and to describe and auto-register the sensors and actuators connected to a beacon. Thus, three protocols are defined depending on the beacon hardware characteristics: LP4S-6 (for resource-constraint beacons), LP4S-X (for more powerful beacons) and LP4S-J (for beacons able to run complex firmware). In order to demonstrate the capabilities of the designed protocols, the most restrictive (LP4S-6) is tested after implementing it for a telemetry application in a beacon based on Eddystone (Google's open beacon format). Thus, the beacon specification is extended in order to increase its ability to manage unlimited sensors in a telemetry system without interfering in its normal operation with Eddystone frames. The performed experiments show the feasibility of the proposed solution and its superiority, in terms of latency and energy consumption, with respect to approaches based on Generic Attribute Profile (GATT) when multiple users connect to a mote or in scenarios where latency is not a restriction, but where low-energy consumption is essential.

  6. Design and Practical Evaluation of a Family of Lightweight Protocols for Heterogeneous Sensing through BLE Beacons in IoT Telemetry Applications

    PubMed Central

    2017-01-01

    The Internet of Things (IoT) involves a wide variety of heterogeneous technologies and resource-constrained devices that interact with each other. Due to such constraints, IoT devices usually require lightweight protocols that optimize the use of resources and energy consumption. Among the different commercial IoT devices, Bluetooth and Bluetooth Low Energy (BLE)-based beacons, which broadcast periodically certain data packets to notify their presence, have experienced a remarkable growth, specially due to their application in indoor positioning systems. This article proposes a family of protocols named Lightweight Protocol for Sensors (LP4S) that provides fast responses and enables plug-and-play mechanisms that allow IoT telemetry systems to discover new nodes and to describe and auto-register the sensors and actuators connected to a beacon. Thus, three protocols are defined depending on the beacon hardware characteristics: LP4S-6 (for resource-constraint beacons), LP4S-X (for more powerful beacons) and LP4S-J (for beacons able to run complex firmware). In order to demonstrate the capabilities of the designed protocols, the most restrictive (LP4S-6) is tested after implementing it for a telemetry application in a beacon based on Eddystone (Google’s open beacon format). Thus, the beacon specification is extended in order to increase its ability to manage unlimited sensors in a telemetry system without interfering in its normal operation with Eddystone frames. The performed experiments show the feasibility of the proposed solution and its superiority, in terms of latency and energy consumption, with respect to approaches based on Generic Attribute Profile (GATT) when multiple users connect to a mote or in scenarios where latency is not a restriction, but where low-energy consumption is essential. PMID:29280975

  7. Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    This paper presents the design and test results of a CW millimeter-wave satellite beacon source, based on the second harmonic from a traveling-wave tube amplifier and utilizes a novel waveguide multimode directional coupler. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37 to 42 GHz) and V/W-band (71 to 76 GHz) satellite-to-ground signals.

  8. Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    This paper presents the design and test results of a CW millimeter-wave satellite beacon source, based on the second harmonic from a traveling-wave tube amplifier and utilizes a novel waveguide multimode directional coupler. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37-42 GHz) and V/W-band (71- 76 GHz) satellite-to-ground signals.

  9. The 406 MHz ELT/EPIRBs. [Emergency Locator Transmitters/Emergency Position Indicating Radio Beacons (ELT/EPIRB)

    NASA Technical Reports Server (NTRS)

    Flatow, F. S.; Gal, C.; Hayes, E. J.

    1984-01-01

    Specifications for the COSPAS/SARSAT beacons are presented and related design considerations are discussed. Critical design aspects having significant impact on cost and performance are highlighted. Among these is the oscillator, whose frequency drift specifications require stabilization by ovens or digital control. Design options are presented and their impact on cost and performance assessed. Beacon designs developed to meet COSPAS/SARSAT specifications are shown.

  10. COSPAS/SARSAT 406-MHz emergency beacon digital controller

    NASA Technical Reports Server (NTRS)

    Ivancic, William D.

    1988-01-01

    The digital control portion of a low-cost 406-MHz COSPAS/SARSAT emergency beacon has been designed and breadboarded at the NASA Lewis Research Center. This report discusses the requirements and design tradeoffs of the digital controller and describes the hardware and software design, which is available only to United States citizens and companies.

  11. Bilingual Education and Academic/Career Outreach for Newcomers: Project BEACON, 1988-89. Evaluation Section Report. OREA Report.

    ERIC Educational Resources Information Center

    Berney, Tomi D.; Gritzer, Glenn

    The Bilingual Education Academic/Career Outreach for Newcomers Program (Project BEACON) completed its fourth year. The goals of Project BEACON are to facilitate acquisition of English proficiency, develop native language literacy skills, and provide instruction in bilingual and English content area/vocational classes. The project served 753…

  12. Radiometer calibration procedure and beacon attenuation estimation reference level

    NASA Technical Reports Server (NTRS)

    Crane, Robert K.

    1994-01-01

    The primary objectives are to compare radiometer attenuation with beacon attenuation and to compare sky temperature estimates with calculations using simultaneous meteorological data. Secondary objectives are: (1) noise diode and reference load measurements and (2) to adjust for outside temperature and component temperature changes.

  13. Visual format for detection of Mycobacterium tuberculosis and M. bovis in clinical samples using molecular beacons.

    PubMed

    Kumar, Parameet; Nath, Kapili; Rath, Bimba; Sen, Manas K; Vishalakshi, Potharuju; Chauhan, Devender S; Katoch, Vishwa M; Singh, Sarman; Tyagi, Sanjay; Sreenivas, Vishnubhatla; Prasad, Hanumanthappa K

    2009-09-01

    A real-time polymerase chain reaction (PCR) assay for the direct identification of Mycobacterium tuberculosis and M. bovis using molecular beacons was developed. The assay was modified for use in regular thermal cyclers. Molecular beacons that were specific for M. tuberculosis (Tb-B) and M. bovis (Bo-B) were designed. The fluorescence of the target PCR product-molecular beacon probe complex was detected visually using a transilluminator. The results were then compared with those of conventional multiplex PCR (CM-PCR) assays and biochemical identification. The detection limit of Tb-B and Bo-B beacons was 500 fg and 50 fg by the visual format and real-time PCR assay, respectively, compared with 5 pg by CM-PCR assay. Pulmonary and extrapulmonary samples were examined. The agreement between culture and the two assays was very good in sputum samples and fair in extrapulmonary samples. The agreement between clinical diagnoses with the two assays was moderate in extrapulmonary samples. There was very good agreement between CM-PCR and visual format assays for all samples used in the study. Concordance in the identification of isolates by the visual, CM-PCR assay, and biochemical identification was seen. Hence, the use of molecular beacon detection of M. tuberculosis and M. bovis in clinical samples is feasible by setting up two asymmetric PCRs concurrently. The assay is sensitive, specific, simple to interpret, and takes less than 3 hours to complete.

  14. Visual Format for Detection of Mycobacterium tuberculosis and M. bovis in Clinical Samples Using Molecular Beacons

    PubMed Central

    Kumar, Parameet; Nath, Kapili; Rath, Bimba; Sen, Manas K.; Vishalakshi, Potharuju; Chauhan, Devender S.; Katoch, Vishwa M.; Singh, Sarman; Tyagi, Sanjay; Sreenivas, Vishnubhatla; Prasad, Hanumanthappa K.

    2009-01-01

    A real-time polymerase chain reaction (PCR) assay for the direct identification of Mycobacterium tuberculosis and M. bovis using molecular beacons was developed. The assay was modified for use in regular thermal cyclers. Molecular beacons that were specific for M. tuberculosis (Tb-B) and M. bovis (Bo-B) were designed. The fluorescence of the target PCR product-molecular beacon probe complex was detected visually using a transilluminator. The results were then compared with those of conventional multiplex PCR (CM-PCR) assays and biochemical identification. The detection limit of Tb-B and Bo-B beacons was 500 fg and 50 fg by the visual format and real-time PCR assay, respectively, compared with 5 pg by CM-PCR assay. Pulmonary and extrapulmonary samples were examined. The agreement between culture and the two assays was very good in sputum samples and fair in extrapulmonary samples. The agreement between clinical diagnoses with the two assays was moderate in extrapulmonary samples. There was very good agreement between CM-PCR and visual format assays for all samples used in the study. Concordance in the identification of isolates by the visual, CM-PCR assay, and biochemical identification was seen. Hence, the use of molecular beacon detection of M. tuberculosis and M. bovis in clinical samples is feasible by setting up two asymmetric PCRs concurrently. The assay is sensitive, specific, simple to interpret, and takes less than 3 hours to complete. PMID:19661384

  15. Evaluation of light-emitting diode beacon light fixtures : final report.

    DOT National Transportation Integrated Search

    2009-12-01

    Rotating beacons containing filament light sources have long been used on highway maintenance trucks : to indicate the presence of the truck to other drivers. Because of advances in light-emitting diode (LED) : technologies, flashing lights containin...

  16. Building Partnerships with Agencies & Employers To Help High Risk Students Succeed. The AACJC/Kellogg Beacon Colleges Initiative.

    ERIC Educational Resources Information Center

    American Association of Community and Junior Colleges, Washington, DC.

    The American Association of Community and Junior Colleges' (AACJC's) Beacon College Project requires a Beacon College to form a consortium with five to ten associate community colleges (CCs) for the purpose of furthering the recommendations of the AACJC Futures Commission report regarding the building of communities. In Oregon, Chemeketa Community…

  17. Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    The design and test results of a novel waveguide multimode directional coupler for a CW millimeter-wave satellite beacon source are presented. The coupler separates the second harmonic power from the fundamental output power of a traveling-wave tube amplifier. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37 to 42 GHz) and VW-band (71 to 76 GHz) satellite-to-ground signals.

  18. A quantum dot-aptamer beacon using a DNA intercalating dye as the FRET reporter: application to label-free thrombin detection.

    PubMed

    Chi, Chun-Wei; Lao, Yeh-Hsing; Li, Yi-Shan; Chen, Lin-Chi

    2011-03-15

    A new quantum dot (QD)-aptamer (apt) beacon that acts by folding-induced dissociation of a DNA intercalating dye, BOBO-3(B), is demonstrated with label-free thrombin detection. The beacon, denoted as QD-apt:B, is constructed by (1) coupling of a single-stranded thrombin aptamer to Qdot 565 via EDC/Sulfo-NHS chemistry and (2) staining the duplex regions of the aptamer on QD with excess BOBO-3 before thrombin binding. When mixing a thrombin sample with QD-apt:B, BOBO-3 is competed away from the beacon due to target-induced aptamer folding, which then causes a decrease in QD fluorescence resonance energy transfer (FRET)-mediated BOBO-3 emission and achieves thrombin quantitation. In this work, the effects of Mg(2+), coupling time, and aptamer type on the beacon's performances are investigated and discussed thoroughly with various methods, including transmission electron microscopy (TEM), dynamic light scattering (DLS), and two-color differential gel electrophoresis. Using the best aptamer beacon (HTQ37), we attain highly specific and wide-range detection (from nM to μM) of thrombin in buffer, and the beacon can sense nM-range thrombin in 15% diluted serum. Compared to the reported QD aptamer assays, our method is advantageous from the aspect of using a simple sensory unit design without losing the detection sensitivity. Therefore, we consider the QD-apt:B beacon a potential alternative to immuno-reagents and an effective tool to study nucleic acid folding on QD as well. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. GaAs monolithic R.F. modules for SARSAT distress beacons

    NASA Technical Reports Server (NTRS)

    Cauley, Michael A.

    1991-01-01

    Monolithic GaAs UHF components for use in SARSAT Emergency Distress beacons are under development by Microwave Monolithics, Inc., Simi Valley, CA. The components include a bi-phase modulator, driver amplifier, and a 5 watt power amplifier.

  20. The Development of Landmark and Beacon Use in Young Children: Evidence from a Touchscreen Search Task

    ERIC Educational Resources Information Center

    Sutton, Jennifer E.

    2006-01-01

    Children ages 2, 3 and 4 years participated in a novel hide-and-seek search task presented on a touchscreen monitor. On beacon trials, the target hiding place could be located using a beacon cue, but on landmark trials, searching required the use of a nearby landmark cue. In Experiment 1, 2-year-olds performed less accurately than older children…

  1. HRO: A New Forward-Scatter Observation Method Using a Ham-Band Beacon

    NASA Astrophysics Data System (ADS)

    Maegawa, K.

    1999-02-01

    A new forward-scatter meteor observation method has been used since 1996 in Japan. It uses its own 50 W continuous wave beacon with a broad directivity antenna on 53.750 MHz. To compensate for the weak echo power from the beacon, observers use SSB mode receivers and narrow band echo detection methods with Fast Fourier Transform software on personal computers. More than 250000 echoes have been counted per year so far. >From these results, diurnal and seasonal variations have been derived and are presented and discussed here. This method (HRO) will continue to play a leading radio observation role in Japan for the future.

  2. Modulation and coding for a compatible Discrete Address Beacon System.

    DOT National Transportation Integrated Search

    1972-02-01

    One of several possible candidate configurations for the Discrete Address System is described. The configuration presented is compatible with the Air Traffic Control Radar Beacon System, and it provides for gradual transition from one system to the o...

  3. Diagnosis of Neisseria gonorrhoeae Using Molecular Beacon

    PubMed Central

    Patel, Achchhe Lal; Sonkar, Subash Chandra; Kumari, Indu; Saluja, Daman

    2015-01-01

    Neisseria gonorrhoeae is an important sexually transmitted diseases (STD) causing pathogen worldwide. Due to absence of an affordable diagnostic assay, routine screening of gonococcal infection becomes impossible in developing countries where infection rates are maximum. Treatment is given on the basis of symptoms alone which leads to spread of infection. Thus, development of a rapid, sensitive, specific, and PCR based visual diagnostic assay suitable for developing countries, required for better disease management, is aimed at in present study. Endocervical swabs were collected from patients visiting gynecology department of various hospitals in Delhi. In-house PCR based assay was developed and modified to visual assay using molecular beacon for end-point detection. It was evaluated against Roche AMPLICOR NG kit and rmp gene. Specificity of beacon was confirmed by competition experiments. Diagnostic test was 98.21% specific and 99.59% sensitive whereas negative and positive predicted value were 99.40% and 98.78%, respectively. We also observed that twice the concentration (2X) of premix was stable at 4°C for 4 months and dry swab samples gave concordant results with that of wet swabs. These features make the test best suitable for routine diagnosis of genital infections in developing countries. PMID:25802857

  4. Hybrid diagnostic system: beacon-based exception analysis for multimissions - Livingstone integration

    NASA Technical Reports Server (NTRS)

    Park, Han G.; Cannon, Howard; Bajwa, Anupa; Mackey, Ryan; James, Mark; Maul, William

    2004-01-01

    This paper describes the initial integration of a hybrid reasoning system utilizing a continuous domain feature-based detector, Beacon-based Exceptions Analysis for Multimissions (BEAM), and a discrete domain model-based reasoner, Livingstone.

  5. A Beacon Transmission Power Control Algorithm Based on Wireless Channel Load Forecasting in VANETs.

    PubMed

    Mo, Yuanfu; Yu, Dexin; Song, Jun; Zheng, Kun; Guo, Yajuan

    2015-01-01

    In a vehicular ad hoc network (VANET), the periodic exchange of single-hop status information broadcasts (beacon frames) produces channel loading, which causes channel congestion and induces information conflict problems. To guarantee fairness in beacon transmissions from each node and maximum network connectivity, adjustment of the beacon transmission power is an effective method for reducing and preventing channel congestion. In this study, the primary factors that influence wireless channel loading are selected to construct the KF-BCLF, which is a channel load forecasting algorithm based on a recursive Kalman filter and employs multiple regression equation. By pre-adjusting the transmission power based on the forecasted channel load, the channel load was kept within a predefined range; therefore, channel congestion was prevented. Based on this method, the CLF-BTPC, which is a transmission power control algorithm, is proposed. To verify KF-BCLF algorithm, a traffic survey method that involved the collection of floating car data along a major traffic road in Changchun City is employed. By comparing this forecast with the measured channel loads, the proposed KF-BCLF algorithm was proven to be effective. In addition, the CLF-BTPC algorithm is verified by simulating a section of eight-lane highway and a signal-controlled urban intersection. The results of the two verification process indicate that this distributed CLF-BTPC algorithm can effectively control channel load, prevent channel congestion, and enhance the stability and robustness of wireless beacon transmission in a vehicular network.

  6. A Beacon Transmission Power Control Algorithm Based on Wireless Channel Load Forecasting in VANETs

    PubMed Central

    Mo, Yuanfu; Yu, Dexin; Song, Jun; Zheng, Kun; Guo, Yajuan

    2015-01-01

    In a vehicular ad hoc network (VANET), the periodic exchange of single-hop status information broadcasts (beacon frames) produces channel loading, which causes channel congestion and induces information conflict problems. To guarantee fairness in beacon transmissions from each node and maximum network connectivity, adjustment of the beacon transmission power is an effective method for reducing and preventing channel congestion. In this study, the primary factors that influence wireless channel loading are selected to construct the KF-BCLF, which is a channel load forecasting algorithm based on a recursive Kalman filter and employs multiple regression equation. By pre-adjusting the transmission power based on the forecasted channel load, the channel load was kept within a predefined range; therefore, channel congestion was prevented. Based on this method, the CLF-BTPC, which is a transmission power control algorithm, is proposed. To verify KF-BCLF algorithm, a traffic survey method that involved the collection of floating car data along a major traffic road in Changchun City is employed. By comparing this forecast with the measured channel loads, the proposed KF-BCLF algorithm was proven to be effective. In addition, the CLF-BTPC algorithm is verified by simulating a section of eight-lane highway and a signal-controlled urban intersection. The results of the two verification process indicate that this distributed CLF-BTPC algorithm can effectively control channel load, prevent channel congestion, and enhance the stability and robustness of wireless beacon transmission in a vehicular network. PMID:26571042

  7. Indoor Pedestrian Localization Using iBeacon and Improved Kalman Filter.

    PubMed

    Sung, Kwangjae; Lee, Dong Kyu 'Roy'; Kim, Hwangnam

    2018-05-26

    The reliable and accurate indoor pedestrian positioning is one of the biggest challenges for location-based systems and applications. Most pedestrian positioning systems have drift error and large bias due to low-cost inertial sensors and random motions of human being, as well as unpredictable and time-varying radio-frequency (RF) signals used for position determination. To solve this problem, many indoor positioning approaches that integrate the user's motion estimated by dead reckoning (DR) method and the location data obtained by RSS fingerprinting through Bayesian filter, such as the Kalman filter (KF), unscented Kalman filter (UKF), and particle filter (PF), have recently been proposed to achieve higher positioning accuracy in indoor environments. Among Bayesian filtering methods, PF is the most popular integrating approach and can provide the best localization performance. However, since PF uses a large number of particles for the high performance, it can lead to considerable computational cost. This paper presents an indoor positioning system implemented on a smartphone, which uses simple dead reckoning (DR), RSS fingerprinting using iBeacon and machine learning scheme, and improved KF. The core of the system is the enhanced KF called a sigma-point Kalman particle filter (SKPF), which localize the user leveraging both the unscented transform of UKF and the weighting method of PF. The SKPF algorithm proposed in this study is used to provide the enhanced positioning accuracy by fusing positional data obtained from both DR and fingerprinting with uncertainty. The SKPF algorithm can achieve better positioning accuracy than KF and UKF and comparable performance compared to PF, and it can provide higher computational efficiency compared with PF. iBeacon in our positioning system is used for energy-efficient localization and RSS fingerprinting. We aim to design the localization scheme that can realize the high positioning accuracy, computational efficiency, and

  8. Dual-band beacon experiment over Southeast Asia for ionospheric irregularity analysis

    NASA Astrophysics Data System (ADS)

    Watthanasangmechai, K.; Yamamoto, M.; Saito, A.; Saito, S.; Maruyama, T.; Tsugawa, T.; Nishioka, M.

    2013-12-01

    An experiment of dual-band beacon over Southeast Asia was started in March 2012 in order to capture and analyze ionospheric irregularities in equatorial region. Five GNU Radio Beacon Receivers (GRBRs) were aligned along 100 degree geographic longitude. The distances between the stations reach more than 500 km. The field of view of this observational network covers +/- 20 degree geomagnetic latitude including the geomagnetic equator. To capture ionospheric irregularities, the absolute TEC estimation technique was developed. The two-station method (Leitinger et al., 1975) is generally accepted as a suitable method to estimate TEC offsets of dual-band beacon experiment. However, the distances between the stations directly affect on the robustness of the technique. In Southeast Asia, the observational network is too sparse to attain a benefit of the classic two-station method. Moreover, the least-squares approch used in the two-station method tries too much to adjust the small scales of the TEC distribution which are the local minima. We thus propose a new technique to estimate the TEC offsets with the supporting data from absolute GPS-TEC from local GPS receivers and the ionospheric height from local ionosondes. The key of the proposed technique is to utilize the brute-force technique with weighting function to find the TEC offset set that yields a global minimum of RMSE in whole parameter space. The weight is not necessary when the TEC distribution is smooth, while it significantly improves the TEC estimation during the ESF events. As a result, the latitudinal TEC shows double-hump distribution because of the Equatorial Ionization Anomaly (EIA). In additions, the 100km-scale fluctuations from an Equatorial Spread F (ESF) are captured at night time in equinox seasons. The plausible linkage of the meridional wind with triggering of ESF is under invatigating and will be presented. The proposed method is successful to estimate the latitudinal TEC distribution from dual

  9. Automated Internet-Based Control of Spacecraft Groundstations: Beacon-Based Health Monitoring Concept

    NASA Technical Reports Server (NTRS)

    Cantwell, Brian; Twiggs, Robert; Swartwout, Michael

    1997-01-01

    This report serves as an update about the activities of Stanford University's Space Systems Development Laboratory (SSDL) in their beacon-based health monitoring experiment. Section 1 describes the goals of the project and the organization of the team. Section 2 provides an overview of the major components of the system, describing the general approach of automated health monitoring and the beacon signal relay. It also provides background about the SAPPHIRE spacecraft and ASSET operations system, which will be used for the experiment. Specific details about implementation and status of each element of the experiment are found in Section 3. Section 4 describes the experiment and future work, and references are contained in Section 5.

  10. Novel approach for beacon formation through simulated turbulence: initial lab-test results

    NASA Astrophysics Data System (ADS)

    Khizhnyak, A.; Markov, V.; Tomov, I.; Wu, F.

    2010-02-01

    In this paper we report the results of the analysis and experimental modeling of the target-in-the-loop (TIL) approach that is used to form a localized beacon for a laser beam propagating through turbulent atmosphere. The analogy between the TIL system and the laser cavity has been used here to simulate the process shaping the laser beacon on a remote image-resolved target with rough surface. The TIL breadboard was integrated and used for laboratory modeling of the proposed approach. This breadboard allowed to simulate the TIL arrangement with a rough-surface target and laser beam propagation through the turbulent atmospheric layer. Here we present the initial results of the performed studies.

  11. Beacon communities aim to use health information technology to transform the delivery of care.

    PubMed

    Maxson, Emily R; Jain, Sachin H; McKethan, Aaron N; Brammer, Craig; Buntin, Melinda Beeuwkes; Cronin, Kelly; Mostashari, Farzad; Blumenthal, David

    2010-09-01

    The Beacon Community Program, authorized under the 2009 American Recovery and Reinvestment Act (ARRA), aims to demonstrate the potential for health information technology to enable local improvements in health care quality, cost efficiency, and population health. If successful, these communitywide efforts will yield important lessons that will assist other communities seeking to harness technology to achieve and sustain health care improvements. This paper highlights key programmatic details that reflect the meaningful use of technology in the fifteen Beacon communities. It describes the innovations they propose and provides insight into current and future challenges.

  12. A Novel Strategy for Human Papillomavirus Detection and Genotyping with SybrGreen and Molecular Beacon Polymerase Chain Reaction

    PubMed Central

    Szuhai, Károly; Sandhaus, Emily; Kolkman-Uljee, Sandra M.; Lemaître, Marc; Truffert, Jean-Christophe; Dirks, Roeland W.; Tanke, Hans J.; Fleuren, Gert Jan; Schuuring, Ed; Raap, Anton K.

    2001-01-01

    Human papillomaviruses (HPVs) play an important role in the pathogenesis of cervical cancer. For identification of the large number of different HPV types found in (pre)malignant lesions, a robust methodology is needed that combines general HPV detection with HPV genotyping. We have developed for formaldehyde-fixed samples a strategy that, in a homogenous, real-time fluorescence polymerase chain reaction (PCR)-based assay, accomplishes general HPV detection by SybrGreen reporting of HPV-DNA amplicons, and genotyping of seven prevalent HPV types (HPV-6, -11, -16, -18, -31, -33, -45) by real-time molecular beacon PCR. The false-positive rate of the HPV SybrGreen-PCR was 4%, making it well suited as a prescreening, general HPV detection technology. The type specificity of the seven selected HPV molecular beacons was 100% and double infections were readily identified. The multiplexing capacity of the HPV molecular beacon PCR was analyzed and up to three differently labeled molecular beacons could be used in one PCR reaction without observing cross talk. The inherent quantitation capacities of real-time fluorescence PCR allowed the determination of average HPV copy number per cell. We conclude that the HPV SybrGreen-PCR in combination with the HPV molecular beacon PCR provides a robust, sensitive, and quantitative general HPV detection and genotyping methodology. PMID:11696426

  13. Beacon Collision Avoidance System (BCAS) Alternative Concepts for Determining Target Positions

    DOT National Transportation Integrated Search

    1978-09-01

    The (Litchford) Beacon-based Collision Avoidance System concept requires the computation of target range and bearing relative to the BCAS aircraft. Techniques for determining target range and bearing under four different assumptions about the ground ...

  14. Aircraft Position Measurement Using Laser Beacon Optics.

    DTIC Science & Technology

    1981-01-01

    8217Comparison of Solar Concentrators .’ Solar Energy, Vol. 10, p. 93, 1976. 7. Winston , R., ’Light Collection Within the Framework of Goemetrical Optics ...8217 J. Optical Society of Am., Vol. 60, p. 245, 1970. 8. Welford, W. T., tics of Nonimaging Concentrators . New York, Academic Press, T978. 9. Bracewell...helicopter pilot and the flight engineer on board the YO-3A. This thesis will concentrate on the development of the laser beacon, the detector optics

  15. Early Detection of Breast Cancer Using Molecular Beacons

    DTIC Science & Technology

    2008-01-01

    a molecular beacon (MB)-based approach for direct examination of gene expression in viable and fixed cells (2, 3). This objective of proposed study ...can be distinguished from normal cells (dark) (Figure 1) (2, 3, 8). Recently, a class of new fluorescent emitting nanoparticles, semiconductor ...morphological classification. This method may offer a simple and fast procedure to detect biomarker gene expression in clinical samples. Our study results

  16. [Molecular beacon based PNA-FISH method combined with fluorescence scanning for rapid detection of Listeria monocytogenes].

    PubMed

    Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen

    2016-07-04

    To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.

  17. Rapid detection of rifampin resistance in Mycobacterium tuberculosis isolates from India and Mexico by a molecular beacon assay.

    PubMed

    Varma-Basil, Mandira; El-Hajj, Hiyam; Colangeli, Roberto; Hazbón, Manzour Hernando; Kumar, Sujeet; Bose, Mridula; Bobadilla-del-Valle, Miriam; García, Lourdes García; Hernández, Araceli; Kramer, Fred Russell; Osornio, Jose Sifuentes; Ponce-de-León, Alfredo; Alland, David

    2004-12-01

    We assessed the performance of a rapid, single-well, real-time PCR assay for the detection of rifampin-resistant Mycobacterium tuberculosis by using clinical isolates from north India and Mexico, regions with a high incidence of tuberculosis. The assay uses five differently colored molecular beacons to determine if a short region of the M. tuberculosis rpoB gene contains mutations that predict rifampin resistance in most isolates. Until now, the assay had not been sufficiently tested on samples from countries with a high incidence of tuberculosis. In the present study, the assay detected mutations in 16 out of 16 rifampin-resistant isolates from north India (100%) and in 55 of 64 rifampin-resistant isolates from Mexico (86%) compared to results with standard susceptibility testing. The assay did not detect mutations (a finding predictive of rifampin susceptibility) in 37 out of 37 rifampin-susceptible isolates from India (100%) and 125 out of 126 rifampin-susceptible isolates from Mexico (99%). DNA sequencing revealed that none of the nine rifampin-resistant isolates from Mexico, which were misidentified as rifampin susceptible by the molecular beacon assay, contained a mutation in the region targeted by the molecular beacons. The one rifampin-susceptible isolate from Mexico that appeared to be rifampin resistant by the molecular beacon assay contained an S531W mutation, which is usually associated with rifampin resistance. Of the rifampin-resistant isolates that were correctly identified in the molecular beacon assay, one contained a novel L530A mutation and another contained a novel deletion between codons 511 and 514. Overall, the molecular beacon assay appears to have sufficient sensitivity (89%) and specificity (99%) for use in countries with a high prevalence of tuberculosis.

  18. Improving the detectability of oxygen saturation level targets for preterm neonates: A laboratory test of tremolo and beacon sonifications.

    PubMed

    Deschamps, Marie-Lys; Sanderson, Penelope; Hinckfuss, Kelly; Browning, Caitlin; Loeb, Robert G; Liley, Helen; Liu, David

    2016-09-01

    Recent guidelines recommend oxygen saturation (SpO2) levels of 90%-95% for preterm neonates on supplemental oxygen but it is difficult to discern such levels with current pulse oximetry sonifications. We tested (1) whether adding levels of tremolo to a conventional log-linear pulse oximetry sonification would improve identification of SpO2 ranges, and (2) whether adding a beacon reference tone to conventional pulse oximetry confuses listeners about the direction of change. Participants using the Tremolo (94%) or Beacon (81%) sonifications identified SpO2 range significantly more accurately than participants using the LogLinear sonification (52%). The Beacon sonification did not confuse participants about direction of change. The Tremolo sonification may have advantages over the Beacon sonification for monitoring SpO2 of preterm neonates, but both must be further tested with clinicians in clinically representative scenarios, and with different levels of ambient noise and distractions. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  19. Topical MMP beacon enabled fluorescence-guided resection of oral carcinoma

    PubMed Central

    Burgess, Laura; Chen, Juan; Wolter, Nikolaus E.; Wilson, Brian; Zheng, Gang

    2016-01-01

    Each year almost 300,000 individuals worldwide are diagnosed with oral cancer, more than 90% of these being oral carcinoma [N. Engl. J. Med. 328, 184 19938417385]. Surgical resection is the standard of care, but accurate delineation of the tumor boundaries is challenging, resulting in either under-resection with risk of local recurrence or over-resection with increased functional loss and negative impact on quality of life. This study evaluates, in two pre-clinical in vivo tumor models, the potential of fluorescence-guided resection using molecular beacons activated by metalloproteinases, which are frequently upregulated in human oral cancer. In both models there was rapid (<15 min) beacon activation upon local application, allowing clear fluoresecence imaging in vivo and confirmed by ex vivo fluorescence microscopy and HPLC, with minimal activation in normal oral tissues. Although the tissue penetration was limited using topical application, these findings support further development of this approach towards translation to first-in-human trials. PMID:27231609

  20. The Methodist Hospital CCU: a Beacon unit of excellence.

    PubMed

    Lewis, Tricia; Abanobi, Beatrice; Alleman, Paula; Ballinas, Eva; Botbyl, Brenda; Bries, Girlie; Clark, Liz; Clarkson, Terri; Cooper, Bridgette; Cooper, Jason; Cox, Shelly; Cude, Rebecca; Davis, Juanita; Delosreyes, Arlene; Durst, Kimberly; East, Ana; Edwards, Erving; Ellison, Rose; Eparwa, Perlita; Forjuoh, Harriet; Foster, Donald; Foytik, Lisa; Gordon, Maria; Grace, Jean; Green, Lisa; Harrison, Cassandra; Herrera, Rubin; Horn, Mary; Hunsinger, Cheryce; Issac, Annamma; Jackson, Valerie; Johnson, Athie; Kitayama, Susanna; Karaan, Juliet; Kezmarski, Mary; Kleinrock, Richard; Latson, Maria; Lee, Valerie; Long, Robin; Macapagal, Fred; Magsino, Diana; Manojkumar, Saleena; Martin, Denise; Matura, Lea Ann; McCarthy, Cynthia; McClellan, Emma; McDaniel, Christy; Mengo, Pam; Meurer, Judy; Muttathottil, Liz; Osayande, Esther; Osei-Frimpong, Diana; Phillips, Betty; Pittman, James; Pratt, Craig; Putney, David; Refuerzo, Laarni; Rendon, Lavinia; Richter, Russ; Simms, Sylvia; Sitoy, Diana; Small-Nelson, Judith; Sosa, Tomas; Stuckey, Denise; Tacquard, Natalie; Talbott, Sarah; Talladen, Aleine; Taylor, Shani; Thomas, Lini; Thompson, Pam; Walters, Gordon; West, Rachel

    2005-06-01

    This article features the Coronary Care Unit of The Methodist Hospital of Houston, Texas. This unit was one of the first Beacon Critical Care Units recognized by the American Association of Critical Care Nurses. This article focuses on how to achieve this award. The Coronary Care Unit nursing infrastructure is described, and specific unit examples are included.

  1. From Beacon Valley, Antarctica to Mars: Bringing the PolarTREC Teacher Research Experience to the Classroom

    NASA Astrophysics Data System (ADS)

    Hams, J. E.; Marchant, D. R.

    2009-12-01

    PolarTREC is an educational research experience in which K-14 teachers participate in polar research with scientists as a pathway to improving science education. The program is funded by the National Science Foundation and managed by the Arctic Research Consortium of the United States. Teachers share their experiences with scientists, educators, communities, and students around the world during the expeditions through online journals, and translate the experience to the classroom by developing curricula based on the research expedition. A 2008 PolarTREC teacher research experience involved drilling through buried ice beneath glaciers in one of the Dry Valleys located in the cold-polar desert region of Antarctica. PolarTREC teacher Jacquelyn Hams accompanied Boston University researchers Dr. David Marchant and Sean Mackay to Beacon Valley, Antarctica. Beacon Valley is significant because the ice beneath it is estimated to be over several million years in age, making it the oldest ice known on this planet and it is one of the most Mars-like climatic environments and landscapes on Earth. In order to translate this unique environment to the classroom, lesson plans were created for students to study the topography, glacial landforms, and wind patterns of Beacon Valley. Students also examine the same imagery that scientists use to study the processes that operate in the extreme environments of Antarctica and Mars. The topographic maps and aerial images of Beacon Valley were obtained from the NASA LIMA (Landsat Image Mosaic of Antarctica) website and Mars imagery was obtained from the University of Arizona HiRISE (Hi Resolution Imaging Science Experiment) website. Wind data was downloaded from an anemometer in Beacon Valley and provided courtesy of Sean Mackay of Boston University. The lesson plans are available through the PolarTREC website or by contacting Jacquelyn Hams at hamsje@lavc.edu.

  2. Developing children’s palliative care in Africa through beacon centres: lessons learnt

    PubMed Central

    2013-01-01

    Much progress has been made in the provision of palliative care across sub-Saharan Africa, however much still remains to be done, particularly in the area of children’s palliative care (CPC). The Beacon Centres programme was set up in 2009, aimed at improving access to CPC in South Africa, Uganda and Tanzania through more and better-trained health professionals and CPC clinical services of a high standard. Having identified sites in each country to develop into CPC Beacon Centres, Navigators were identified who would be the ‘champions’ for CPC in those sites and lead a programme of training, mentorship and support. Five navigators (2 in Uganda and Tanzania and 1 in South Africa) were trained between September and December 2009. Following this they undertook CPC needs assessments at the 3 centres and set up and delivered a six-month CPC training programme, providing mentorship and support to students to enable them to integrate CPC into their workplaces. To date, 188 participants have commenced the six-month course, with 80 having completed it. CPC has been integrated into the activities of the centres and a CPC virtual resource centre set up in South Africa. The achievements from the Beacon project have been great and the work of the navigators immense, but as in all projects it has not been without its challenges. Lessons learnt include issues around: the focus of the project; the length and nature of the training; assessment; accreditation; the choice of navigators; mentoring; administrative support; co-ordination; the choice of project sites; and the integration of CPC into services. The need for CPC is not going to go away and it is therefore important that models of scaling-up are found that are not only practical, feasible, affordable and sustainable, but that focus on the outcome of improved CPC for all those who need it. It is hoped that the lessons shared from the Beacon Project will help in developing and implementing such models. PMID:23419095

  3. Long Shelf Life of a Lyophilized DNA Aptamer Beacon Assay.

    PubMed

    Bruno, John G

    2017-03-01

    An aptamer beacon previously developed to detect C-telopeptide (CTx) from human bone collagen breakdown was lyophilized and shown to give a "lights on" concentration-dependent spectral fluorescence response essentially identical to that of the fresh reagent despite storage in a dark dry environment for the past 5.5 years.

  4. Design of a hybrid receiver for the OLYMPUS spacecraft beacons

    NASA Technical Reports Server (NTRS)

    Sweeney, D. G.; Mckeeman, J. C.

    1990-01-01

    The theory and design of a hybrid analogue/digital receiver which acquires and monitors the OLYMPUS satellite beacons is presented. The analogue portion of this receiver uses a frequency locked loop for signal tracking. A digital sampling detector operating at IF is used to obtain the I and Q outputs.

  5. Method and apparatus for a multibeam beacon laser assembly for optical communications

    NASA Technical Reports Server (NTRS)

    Biswas, Abhijit (Inventor); Sanji, Babak (Inventor); Wright, Malcolm W. (Inventor); Page, Norman Alan (Inventor)

    2005-01-01

    An optical beacon is comprised of a telescope having a primary focal plane or Coud? focal plane, a plurality of fiber coupled laser sources for generating a plurality of beams, a collimator for collimating the plurality of beams, and optics for combining and focusing the plurality of collimated beams onto the primary or Coud? focal plane of the telescope. The telescope propagates the optical beacon, which is arranged into a ring of incoherent plurality of collimated beams. The apparatus further comprises fiber splitters coupled to each laser source to provide at least eight beams from at least four laser sources. The optics comprises a prism assembly, a combiner lens, a focusing lens and a field lens for focusing the plurality of collimated beams onto the primary focal plane or Coud? focal plane of the telescope.

  6. Lessons Learned During Implementation and Early Operations of the DS1 Beacon Monitor Experiment

    NASA Technical Reports Server (NTRS)

    Sherwood, Rob; Wyatt, Jay; Hotz, Henry; Schlutsmeyer, Alan; Sue, Miles

    1998-01-01

    A new approach to mission operations will be flight validated on NASA's New Millennium Program Deep Space One (DS1) mission which launched in October 1998. The Beacon Monitor Operations Technology is aimed at decreasing the total volume of downlinked engineering telemetry by reducing the frequency of downlink and the volume of data received per pass. Cost savings are achieved by reducing the amount of routine telemetry processing and analysis performed by ground staff. The technology is required for upcoming NASA missions to Pluto, Europa, and possibly some other missions. With beacon monitoring, the spacecraft will assess its own health and will transmit one of four beacon messages each representing a unique frequency tone to inform the ground how urgent it is to track the spacecraft for telemetry. If all conditions are nominal, the tone provides periodic assurance to ground personnel that the mission is proceeding as planned without having to receive and analyze downlinked telemetry. If there is a problem, the tone will indicate that tracking is required and the resulting telemetry will contain a concise summary of what has occurred since the last telemetry pass. The primary components of the technology are a tone monitoring technology, AI-based software for onboard engineering data summarization, and a ground response system. In addition, there is a ground visualization system for telemetry summaries. This paper includes a description of the Beacon monitor concept, the trade-offs with adapting that concept as a technology experiment, the current state of the resulting implementation on DS1, and our lessons learned during the initial checkout phase of the mission. Applicability to future missions is also included.

  7. Aspect Determination Using a Beacon with a Spiral Wave Front: Modeling and Performance Analysis in Operational Environments

    DTIC Science & Technology

    2014-12-19

    used to evaluate the beacon performance at the Navy’s Seneca Lake Sonar Test Facility operated by NUWC-Newport. These tests occurred in the summer...prototype has been designed. Efforts have been underway to implement the spiral beacon into the Navy’s Sonar Simulation Toolset developed by Dr. Robert...mil). Digital Object Identifier 10.1109/JOE.2013.2293962 acoustic depth finding or sonar imaging may be compared with maps to coordinate position and

  8. Beacon of Hope? Lessons Learned from Efforts to Reduce Civilian Deaths from Police Shootings in an Australian State.

    PubMed

    Saligari, Jessica; Evans, Richard

    2016-04-01

    In the 1990s, the police service in Victoria, Australia, faced a crisis of community confidence due to a spate of civilian deaths from police shootings. In that decade, twice as many civilians died at the hands of the police in Victoria than in every other Australian state combined. Most of those killed were mentally ill and affected by drugs and alcohol, and were rarely a serious threat except to themselves. The problem was also almost entirely an urban phenomenon. Shootings in rural communities, where mentally ill people were more likely to be personally known to local police, were (and remain) almost unknown. The large number of fatalities was recognised as a serious threat to public confidence, and Victoria Police introduced a ground-breaking training programme, Operation Beacon. Operating procedures and weapons training were fundamentally changed, to focus on de-escalation of conflict and avoiding or minimising police use of force. In the short term, Operation Beacon was successful. Shooting incidents were dramatically reduced. However, during the first decade of the new century, the number of civilians being killed again increased. This article examines Operation Beacon, both as a successful model for reducing civilian deaths at the hand of police and as a cautionary tale for police reform. We argue that the lessons of Operation Beacon have been gradually forgotten and that old habits and attitudes resurfaced. Fatal shootings of mentally ill civilians can be prevented, but if success is to be other than temporary, the Beacon philosophy must be continually reemphasised by police management.

  9. Simultaneous and multiplexed detection of exosome microRNAs using molecular beacons.

    PubMed

    Lee, Ji Hye; Kim, Jeong Ah; Jeong, Seunga; Rhee, Won Jong

    2016-12-15

    Simultaneous and multiplexed detection of microRNAs (miRNAs) in a whole exosome is developed, which can be utilized as a PCR-free efficient diagnosis method for various diseases. Exosomes are small extracellular vesicles that contain biomarker miRNAs from parental cells. Because they circulate throughout bodily fluids, exosomal biomarkers offer great advantages for diagnosis in many aspects. In general, PCR-based methods can be used for exosomal miRNA detection but they are laborious, expensive, and time-consuming, which make them unsuitable for high-throughput diagnosis of diseases. Previously, we reported that single miRNA in the exosomes can be detected specifically using an oligonucleotide probe or molecular beacon. Herein, we demonstrate for the first time that multiple miRNAs can be detected simultaneously in exosomes using miRNA-targeting molecular beacons. Exosomes from a breast cancer cell line, MCF-7, were used for the production of exosomes because MCF-7 has a high level of miR-21, miR-375, and miR-27a as target miRNAs. Molecular beacons successfully hybridized with multiple miRNAs in the cancer cell-derived exosomes even in the presence of high human serum concentration. In addition, it is noteworthy that the choice of fluorophores for multiplexing biomarkers in an exosome is crucial because of its small size. The proposed method described in this article is beneficial to high-throughput analysis for disease diagnosis, prognosis, and response to treatment because it is a time-, labor-, and cost-saving technique. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. 76 FR 17625 - Proposed Information Collection; Comment Request; Emergency Beacon Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ... Collection; Comment Request; Emergency Beacon Registrations AGENCY: National Oceanic and Atmospheric... satellites to detect and locate ships, aircraft, or individuals in distress if they are equipped with an... provided by registration can assist in identifying who is in trouble and in suppressing false alarms. II...

  11. Indoor Navigation using Direction Sensor and Beacons

    NASA Technical Reports Server (NTRS)

    Shields, Joel; Jeganathan, Muthu

    2004-01-01

    A system for indoor navigation of a mobile robot includes (1) modulated infrared beacons at known positions on the walls and ceiling of a room and (2) a cameralike sensor, comprising a wide-angle lens with a position-sensitive photodetector at the focal plane, mounted in a known position and orientation on the robot. The system also includes a computer running special-purpose software that processes the sensor readings to obtain the position and orientation of the robot in all six degrees of freedom in a coordinate system embedded in the room.

  12. Caged molecular beacons: controlling nucleic acid hybridization with light.

    PubMed

    Wang, Chunming; Zhu, Zhi; Song, Yanling; Lin, Hui; Yang, Chaoyong James; Tan, Weihong

    2011-05-28

    We have constructed a novel class of light-activatable caged molecular beacons (cMBs) that are caged by locking two stems with a photo-labile biomolecular interaction or covalent bond. With the cMBs, the nucleic acid hybridization process can be easily controlled with light, which offers the possibility for a high spatiotemporal resolution study of intracellular mRNAs. © The Royal Society of Chemistry 2011

  13. Multi-Band Multi-Tone Tunable Millimeter-Wave Frequency Synthesizer For Satellite Beacon Transmitter

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Wintucky, Edwin G.

    2016-01-01

    This paper presents the design and test results of a multi-band multi-tone tunable millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a satellite beacon transmitter for radio wave propagation studies at K-band (18 to 26.5 GHz), Q-band (37 to 42 GHz), and E-band (71 to 76 GHz). In addition, the architecture for a compact beacon transmitter, which includes the multi-tone synthesizer, polarizer, horn antenna, and power/control electronics, has been investigated for a notional space-to-ground radio wave propagation experiment payload on a small satellite. The above studies would enable the design of robust high throughput multi-Gbps data rate future space-to-ground satellite communication links.

  14. Design and implementation of Bluetooth beacon in mobile payment system

    NASA Astrophysics Data System (ADS)

    Han, Tiantian; Ding, Lei

    2017-08-01

    The current line of payment means, mainly in the following ways, cash payment, credit card payment, WeChat Alipay sweep payment. There are many inconvenience in Cash payment, large amounts of cash inconvenience to carry, count the money to spend time and effort, true and false banknotes difficult to distinguish, ticket settlement easy to go wrong. Credit card payment is relatively time-consuming, and WeChat Alipay sweep payment need to sweep. Therefore, the design of a convenient, fast payment to meet the line to pay the demand is particularly important. Based on the characteristics of BLE Bluetooth wireless communication technology, this paper designs a kind of payment method based on Bluetooth beacon. Through the Bluetooth beacon broadcast consumption, consumers only need to open the relevant APP in the Android client, and you can get Bluetooth via mobile phone Bluetooth the amount of consumption of the standard broadcast, in accordance with the corresponding payment platform to complete the payment process, which pay less time to improve the efficiency of payment.

  15. Numerical analysis of hybrid adaptive optics system for correcting beacon anisoplanatism and thermal blooming

    NASA Astrophysics Data System (ADS)

    Belen'kii, Mikhail S.; Rye, Vincent; Runyeon, Hope

    2007-09-01

    A concept of a Hybrid Wavefront-based Stochastic Parallel Gradient Decent (WSPGD) Adaptive Optics (AO) system for correcting the combined effects of Beacon Anisoplanatism and Thermal Blooming is introduced. This system integrates a conventional phase conjugate (PC) AO system with a WSPGD AO system. It uses on-axis wavefront measurements of a laser return from an extended beacon to generate initial deformable mirror (DM) commands. Since high frequency phase components are removed from the wavefront of a laser return by a low-pass filter effect of an extended beacon, the system also uses off-axis wavefront measurements to provide feedback for a multi-dithering beam control algorithm in order to generate additional DM commands that account for those missing high frequency phase components. Performance of the Hybrid WSPGD AO system was evaluated in simulation using a wave optics code. Numerical analysis was performed for two tactical scenarios that included ranges of L = 2 km and L = 20 km, ratio of aperture diameter to Fried parameter, D/r 0, of up to 15, ratio of beam spot size at the target to isoplanatic angle, θ B/θ 0, of up to 40, and general distortion number characterizing the strength of Thermal Blooming, N d = 50, 75, and 100. A line-of-sight in the corrected beam was stabilized using a target-plane tracker. The simulation results reveal that the Hybrid WSPGD AO system can efficiently correct the effects of Beacon Anisoplanatism and Thermal Blooming, providing improved compensation of Thermal Blooming in the presence of strong turbulence. Simulation results also indicate that the Hybrid WSPGD AO system outperforms a conventional PC AO system, increasing the Strehl ratio by up to 300% in less than 50 iterations. A follow-on laboratory demonstration performed under a separate program confirmed our theoretical predictions.

  16. Pedestrian hybrid beacon crosswalk system (PHB) or high-intensity activated crosswalk (HAWK).

    DOT National Transportation Integrated Search

    2014-11-01

    The Pedestrian Hybrid Beacon Crosswalk (PHB) is a type of traffic control system, used to aid : pedestrians safely crossing the street and to regulate traffic flow. This study examines the : success of the first PHB installed in the state of Vermont....

  17. Molecular beacon-based photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Chen, Juan; Stefflova, Klara; Kim, Soungkyoo; Li, Hui; Marotta, Diane; Chance, Britton; Glickson, Jerry D.; Zheng, Gang

    2005-01-01

    A new concept for photodynamic therapy (PDT) has been developed based on incorporating a photosensitizer (PS) and a singlet oxygen (1O2) quenching/scavenging molecule (Q) onto a disease-targeting carrier, such that the PS becomes activatable by light only when targeting has occurred. This has the potential to give very high disease specificity in PDT treatment. The first model compound designed using this concept was synthesized containing a pyropheophorbide as the PS and a carotenoid as the 1O2 quencher. These were kept in close proximity by the self-folding of a caspase-3 specific peptide sequence. Upon caspase-3-induced cleavage, the 1O2 production increase has been validated by direct 1O2 luminescence and lifetime measurements, providing proof-of-concept of this 'PDT beacon.'

  18. Integrated Formulation of Beacon-Based Exception Analysis for Multimissions

    NASA Technical Reports Server (NTRS)

    Mackey, Ryan; James, Mark; Park, Han; Zak, Mickail

    2003-01-01

    Further work on beacon-based exception analysis for multimissions (BEAM), a method of real-time, automated diagnosis of a complex electromechanical systems, has greatly expanded its capability and suitability of application. This expanded formulation, which fully integrates physical models and symbolic analysis, is described. The new formulation of BEAM expands upon previous advanced techniques for analysis of signal data, utilizing mathematical modeling of the system physics, and expert-system reasoning,

  19. A Microfluidic Love-Wave Biosensing Device for PSA Detection Based on an Aptamer Beacon Probe.

    PubMed

    Zhang, Feng; Li, Shuangming; Cao, Kang; Wang, Pengjuan; Su, Yan; Zhu, Xinhua; Wan, Ying

    2015-06-11

    A label-free and selective aptamer beacon-based Love-wave biosensing device was developed for prostate specific antigen (PSA) detection. The device consists of the following parts: LiTaO3 substrate with SiO2 film as wave guide layer, two set of inter-digital transducers (IDT), gold film for immobilization of the biorecongniton layer and a polydimethylsiloxane (PDMS) microfluidic channels. DNA aptamer, or "artificial antibody", was used as the specific biorecognition probe for PSA capture. Some nucleotides were added to the 3'-end of the aptamer to form a duplex with the 3'-end, turning the aptamer into an aptamer-beacon. Taking advantage of the selective target-induced assembly changes arising from the "aptamer beacon", highly selective and specific detection of PSA was achieved. Furthermore, PDMS microfluidic channels were designed and fabricated to realize automated quantitative sample injection. After optimization of the experimental conditions, the established device showed good performance for PSA detection between 10 ng/mL to 1 μg/mL, with a detection limit of 10 ng/mL. The proposed sensor might be a promising alternative for point of care diagnostics.

  20. The Effects of a Rectangular Rapid-Flashing Beacon on Vehicle Speed

    ERIC Educational Resources Information Center

    VanWagner, Michelle; Van Houten, Ron; Betts, Brian

    2011-01-01

    In 2008, nearly 31% of vehicle fatalities were related to failure to adhere to safe vehicle speeds (National Highway Traffic Safety Administration [NHTSA], 2009). The current study evaluated the effect of a rectangular rapid-flashing beacon (RRFB) triggered by excessive speed on vehicle speed using a combined alternating treatments and reversal…

  1. Epilithic lichens in the Beacon sandstone formation, Victoria Land, Antarctica

    NASA Technical Reports Server (NTRS)

    Hale, M. E.; Friedmann, E. I. (Principal Investigator)

    1987-01-01

    The epilithic lichen flora on the Beacon sandstone formation in Victoria Land consists of seven species: Acarospora gwynnii Dodge & Rudolph, Buellia grisea Dodge & Baker, B. pallida Dodge & Baker, Carbonea capsulata (Dodge & Baker) Hale comb. nov., Lecanora fuscobrunnea Dodge & Baker, Lecidea cancriformis Dodge & Baker, and L. siplei Dodge & Baker. The typification of the species is given along with descriptions and distribution in Antarctica.

  2. A molecular-beacon-based asymmetric PCR assay for easy visualization of amplicons in the diagnosis of trichomoniasis.

    PubMed

    Sonkar, Subash C; Sachdev, Divya; Mishra, Prashant K; Kumar, Anita; Mittal, Pratima; Saluja, Daman

    2016-12-15

    The currently available nucleic acid amplification tests (NAATs) for trichomoniasis are accurate, quick and confirmative with superior sensitivity than traditional culture-based microbiology assays. However, these assays are associated with problems of carry over contamination, false positive results, requirement of technical expertise for performance and detection of end product. Hence, a diagnostic assay with easy visualization of the amplified product will be profitable. An in-house, rapid, sensitive, specific molecular-beacon-based PCR assay, using primers against pfoB gene of Trichomonas vaginalis, was developed and evaluated using dry ectocervical swabs (n=392) from symptomatic females with vaginal discharge. Total DNA was isolated and used as template for the PCR assays. The performance and reproducibility of PCR assay was evaluated by composite reference standard (CRS). For easy visualization of the amplified product, molecular-beacon was designed and amplicons were visualized directly using fluorescent handheld dark reader or by Micro-Plate Reader. Molecular-beacons are single-stranded hairpin shaped nucleic acid probes composed of a stem, with fluorophore/quencher pair and a loop region complementary to the desired DNA. The beacon-based PCR assay designed in the present study is highly specific as confirmed by competition experiments and extremely sensitive with detection limit of 20fg of genomic DNA (3-4 pathogens). The minimum infrastructure requirement and ease to perform the assay makes this method highly useful for resource poor countries for better disease management. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Data Governance and Data Sharing Agreements for Community-Wide Health Information Exchange: Lessons from the Beacon Communities

    PubMed Central

    Allen, Claudia; Des Jardins, Terrisca R.; Heider, Arvela; Lyman, Kristin A.; McWilliams, Lee; Rein, Alison L.; Schachter, Abigail A.; Singh, Ranjit; Sorondo, Barbara; Topper, Joan; Turske, Scott A.

    2014-01-01

    Purpose: Unprecedented efforts are underway across the United States to electronically capture and exchange health information to improve health care and population health, and reduce costs. This increased collection and sharing of electronic patient data raises several governance issues, including privacy, security, liability, and market competition. Those engaged in such efforts have had to develop data sharing agreements (DSAs) among entities involved in information exchange, many of whom are “nontraditional” health care entities and/or new partners. This paper shares lessons learned based on the experiences of six federally funded communities participating in the Beacon Community Cooperative Agreement Program, and offers guidance for navigating data governance issues and developing DSAs to facilitate community-wide health information exchange. Innovation: While all entities involved in electronic data sharing must address governance issues and create DSAs accordingly, until recently little formal guidance existed for doing so – particularly for community-based initiatives. Despite this lack of guidance, together the Beacon Communities’ experiences highlight promising strategies for navigating complex governance issues, which may be useful to other entities or communities initiating information exchange efforts to support delivery system transformation. Credibility: For the past three years, AcademyHealth has provided technical assistance to most of the 17 Beacon Communities, 6 of whom contributed to this collaborative writing effort. Though these communities varied widely in terms of their demographics, resources, and Beacon-driven priorities, common themes emerged as they described their approaches to data governance and DSA development. Conclusions: The 6 Beacon Communities confirmed that DSAs are necessary to satisfy legal and market-based concerns, and they identified several specific issues, many of which have been noted by others involved in

  4. Data governance and data sharing agreements for community-wide health information exchange: lessons from the beacon communities.

    PubMed

    Allen, Claudia; Des Jardins, Terrisca R; Heider, Arvela; Lyman, Kristin A; McWilliams, Lee; Rein, Alison L; Schachter, Abigail A; Singh, Ranjit; Sorondo, Barbara; Topper, Joan; Turske, Scott A

    2014-01-01

    Unprecedented efforts are underway across the United States to electronically capture and exchange health information to improve health care and population health, and reduce costs. This increased collection and sharing of electronic patient data raises several governance issues, including privacy, security, liability, and market competition. Those engaged in such efforts have had to develop data sharing agreements (DSAs) among entities involved in information exchange, many of whom are "nontraditional" health care entities and/or new partners. This paper shares lessons learned based on the experiences of six federally funded communities participating in the Beacon Community Cooperative Agreement Program, and offers guidance for navigating data governance issues and developing DSAs to facilitate community-wide health information exchange. While all entities involved in electronic data sharing must address governance issues and create DSAs accordingly, until recently little formal guidance existed for doing so - particularly for community-based initiatives. Despite this lack of guidance, together the Beacon Communities' experiences highlight promising strategies for navigating complex governance issues, which may be useful to other entities or communities initiating information exchange efforts to support delivery system transformation. For the past three years, AcademyHealth has provided technical assistance to most of the 17 Beacon Communities, 6 of whom contributed to this collaborative writing effort. Though these communities varied widely in terms of their demographics, resources, and Beacon-driven priorities, common themes emerged as they described their approaches to data governance and DSA development. The 6 Beacon Communities confirmed that DSAs are necessary to satisfy legal and market-based concerns, and they identified several specific issues, many of which have been noted by others involved in network data sharing initiatives. More importantly, these

  5. Gold nanoparticle-based beacon to detect STAT5b mRNA expression in living cells: a case optimized by bioinformatics screen.

    PubMed

    Deng, Dawei; Li, Yang; Xue, Jianpeng; Wang, Jie; Ai, Guanhua; Li, Xin; Gu, Yueqing

    2015-01-01

    Messenger RNA (mRNA), a single-strand ribonucleic acid with functional gene information is usually abnormally expressed in cancer cells and has become a promising biomarker for the study of tumor progress. Hairpin DNA-coated gold nanoparticle (hDAuNP) beacon containing a bare gold nanoparticle (AuNP) as fluorescence quencher and thiol-terminated fluorescently labeled stem-loop-stem oligonucleotide sequences attached by Au-S bond is currently a new nanoscale biodiagnostic platform capable of mRNA detection, in which the design of the loop region sequence is crucial for hybridizing with the target mRNA. Hence, in this study, to improve the sensitivity and selectivity of hDAuNP beacon simultaneously, the loop region of hairpin DNA was screened by bioinformatics strategy. Here, signal transducer and activator of transcription 5b (STAT5b) mRNA was selected and used as a practical example. The results from the combined characterizations using optical techniques, flow cytometry assay, and cell microscopic imaging showed that after optimization, the as-prepared hDAuNP beacon had higher selectivity and sensitivity for the detection of STAT5b mRNA in living cells, as compared with our previous beacon. Thus, the bioinformatics method may be a promising new strategy for assisting in the designing of the hDAuNP beacon, extending its application in the detection of mRNA expression and the resultant mRNA-based biological processes and disease pathogenesis.

  6. Gold nanoparticle-based beacon to detect STAT5b mRNA expression in living cells: a case optimized by bioinformatics screen

    PubMed Central

    Deng, Dawei; Li, Yang; Xue, Jianpeng; Wang, Jie; Ai, Guanhua; Li, Xin; Gu, Yueqing

    2015-01-01

    Messenger RNA (mRNA), a single-strand ribonucleic acid with functional gene information is usually abnormally expressed in cancer cells and has become a promising biomarker for the study of tumor progress. Hairpin DNA-coated gold nanoparticle (hDAuNP) beacon containing a bare gold nanoparticle (AuNP) as fluorescence quencher and thiol-terminated fluorescently labeled stem–loop–stem oligonucleotide sequences attached by Au–S bond is currently a new nanoscale biodiagnostic platform capable of mRNA detection, in which the design of the loop region sequence is crucial for hybridizing with the target mRNA. Hence, in this study, to improve the sensitivity and selectivity of hDAuNP beacon simultaneously, the loop region of hairpin DNA was screened by bioinformatics strategy. Here, signal transducer and activator of transcription 5b (STAT5b) mRNA was selected and used as a practical example. The results from the combined characterizations using optical techniques, flow cytometry assay, and cell microscopic imaging showed that after optimization, the as-prepared hDAuNP beacon had higher selectivity and sensitivity for the detection of STAT5b mRNA in living cells, as compared with our previous beacon. Thus, the bioinformatics method may be a promising new strategy for assisting in the designing of the hDAuNP beacon, extending its application in the detection of mRNA expression and the resultant mRNA-based biological processes and disease pathogenesis. PMID:25987838

  7. Preliminary Statistics from the NASA Alphasat Beacon Receiver in Milan, Italy

    NASA Technical Reports Server (NTRS)

    Zemba, Michael J.; Nessel, James A.; Morse, Jacquelynne R.

    2015-01-01

    NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 GHz band. NASA GRC has developed and installed a KQ-band (20-40 GHz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20-40 GHz signals broadcast from the Alphasat Aldo Paraboni TDP5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we provide an overview of the design and data calibration procedure, and present 6 months of preliminary statistics of the NASA propagation terminal, which has been installed and operating in Milan since May 2014. The Q-band receiver has demonstrated a dynamic range of 40 dB at an 8-Hz sampling rate. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models

  8. Preliminary Statistics from the NASA Alphasat Beacon Receiver in Milan, Italy

    NASA Technical Reports Server (NTRS)

    Nessel, James; Zemba, Michael; Morse, Jacquelynne; Luini, Lorenzo; Riva, Carlo

    2015-01-01

    NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 gigahertz band. NASA GRC has developed and installed a K/Q-band (20/40 gigahertz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 gigahertz signals broadcast from the Alphasat Aldo Paraboni TDP no. 5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we provide an overview of the design and data calibration procedure, and present 6 months of preliminary statistics of the NASA propagation terminal, which has been installed and operating in Milan since May 2014. The Q-band receiver has demonstrated a dynamic range of 40 decibels at an 8-hertz sampling rate. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

  9. Modeling Self-Referencing Interferometers with Extended Beacons and Strong Turbulence

    DTIC Science & Technology

    2011-09-01

    identified then typically compensated. These results not only serve to address problems when using adaptive optics to correct for strong turbulence ...compensat- ing for distortions due to atmospheric turbulence with adaptive optics (AO) [70, 84]. AO typically compensates for atmospheric distortions... used in Chapter VII to discuss how strong atmospheric turbulence and extended beacons affect the performance of an SRI. Additionally, it enumerates the

  10. The Roles of Beaconing and Dead Reckoning in Human Virtual Navigation

    ERIC Educational Resources Information Center

    Bodily, Kent D.; Daniel, Thomas A.; Sturz, Bradley R.

    2012-01-01

    Beaconing is a process in which the distance between a visual landmark and current position is reduced in order to return to a location. In contrast, dead reckoning is a process in which vestibular, kinesthetic and/or optic flow cues are utilized to update speed of movement, elapsed time of movement, and direction of movement to return to a…

  11. Molecular beacon probes-base multiplex NASBA Real-time for detection of HIV-1 and HCV.

    PubMed

    Mohammadi-Yeganeh, S; Paryan, M; Mirab Samiee, S; Kia, V; Rezvan, H

    2012-06-01

    Developed in 1991, nucleic acid sequence-based amplification (NASBA) has been introduced as a rapid molecular diagnostic technique, where it has been shown to give quicker results than PCR, and it can also be more sensitive. This paper describes the development of a molecular beacon-based multiplex NASBA assay for simultaneous detection of HIV-1 and HCV in plasma samples. A well-conserved region in the HIV-1 pol gene and 5'-NCR of HCV genome were used for primers and molecular beacon design. The performance features of HCV/HIV-1 multiplex NASBA assay including analytical sensitivity and specificity, clinical sensitivity and clinical specificity were evaluated. The analysis of scalar concentrations of the samples indicated that the limit of quantification of the assay was <1000 copies/ml for HIV-1 and <500 copies/ml for HCV with 95% confidence interval. Multiplex NASBA assay showed a 98% sensitivity and 100% specificity. The analytical specificity study with BLAST software demonstrated that the primers do not attach to any other sequences except for that of HIV-1 or HCV. The primers and molecular beacon probes detected all HCV genotypes and all major variants of HIV-1. This method may represent a relatively inexpensive isothermal method for detection of HIV-1/HCV co-infection in monitoring of patients.

  12. A distance-dependent metal-enhanced fluorescence sensing platform based on molecular beacon design.

    PubMed

    Zhou, Zhenpeng; Huang, Hongduan; Chen, Yang; Liu, Feng; Huang, Cheng Zhi; Li, Na

    2014-02-15

    A new metal-enhanced fluorescence (MEF) based platform was developed on the basis of distance-dependent fluorescence quenching-enhancement effect, which combined the easiness of Ag-thiol chemistry with the MEF property of noble-metal structures as well as the molecular beacon design. For the given sized AgNPs, the fluorescence enhancement factor was found to increase with a d(6) dependency in agreement with fluorescence resonance energy transfer mechanism at shorter distance and decrease with a d(-3) dependency in agreement with plasmonic enhancement mechanism at longer distance between the fluorophore and the AgNP surface. As a proof of concept, the platform was demonstrated by a sensitive detection of mercuric ions, using thymine-containing molecular beacon to tune silver nanoparticle (AgNP)-enhanced fluorescence. Mercuric ions were detected via formation of a thymine-mercuric-thymine structure to open the hairpin, facilitating fluorescence recovery and AgNP enhancement to yield a limit of detection of 1 nM, which is well below the U.S. Environmental Protection Agency regulation of the Maximum Contaminant Level Goal (10nM) in drinking water. Since the AgNP functioned as not only a quencher to reduce the reagent blank signal but also an enhancement substrate to increase fluorescence of the open hairpin when target mercuric ions were present, the quenching-enhancement strategy can greatly improve the detection sensitivity and can in principle be a universal approach for various targets when combined with molecular beacon design. © 2013 Elsevier B.V. All rights reserved.

  13. Making it local: Beacon Communities use health information technology to optimize care management.

    PubMed

    Allen, Amy; Des Jardins, Terrisca R; Heider, Arvela; Kanger, Chatrian R; Lobach, David F; McWilliams, Lee; Polello, Jennifer M; Rein, Alison L; Schachter, Abigail A; Singh, Ranjit; Sorondo, Barbara; Tulikangas, Megan C; Turske, Scott A

    2014-06-01

    Care management aims to provide cost-effective, coordinated, non-duplicative care to improve care quality, population health, and reduce costs. The 17 communities receiving funding from the Office of the National Coordinator for Health Information Technology through the Beacon Community Cooperative Agreement Program are leaders in building and strengthening their health information technology (health IT) infrastructure to provide more effective and efficient care management. This article profiles 6 Beacon Communities' health IT-enabled care management programs, highlighting the influence of local context on program strategy and design, and describing challenges, lessons learned, and policy implications for care delivery and payment reform. The unique needs (eg, disease burden, demographics), community partnerships, and existing resources and infrastructure all exerted significant influence on the overall priorities and design of each community's care management program. Though each Beacon Community needed to engage in a similar set of care management tasks--including patient identification, stratification, and prioritization; intervention; patient engagement; and evaluation--the contextual factors helped shape the specific strategies and tools used to carry out these tasks and achieve their objectives. Although providers across the country are striving to deliver standardized, high-quality care, the diverse contexts in which this care is delivered significantly influence the priorities, strategies, and design of community-based care management interventions. Gaps and challenges in implementing effective community-based care management programs include: optimizing allocation of care management services; lack of available technology tailored to care management needs; lack of standards and interoperability; integrating care management into care settings; evaluating impact; and funding and sustainability.

  14. Multi-level obstruction in obstructive sleep apnoea: prevalence, severity and predictive factors.

    PubMed

    Phua, C Q; Yeo, W X; Su, C; Mok, P K H

    2017-11-01

    To characterise multi-level obstruction in terms of prevalence, obstructive sleep apnoea severity and predictive factors, and to collect epidemiological data on upper airway morphology in obstructive sleep apnoea patients. Retrospective review of 250 obstructive sleep apnoea patients. On clinical examination, 171 patients (68.4 per cent) had multi-level obstruction, 49 (19.6 per cent) had single-level obstruction and 30 (12 per cent) showed no obstruction. Within each category of obstructive sleep apnoea severity, multi-level obstruction was more prevalent. Multi-level obstruction was associated with severe obstructive sleep apnoea (more than 30 events per hour) (p = 0.001). Obstructive sleep apnoea severity increased with the number of obstruction sites (correlation coefficient = 0.303, p < 0.001). Multi-level obstruction was more likely in younger (p = 0.042), male (p = 0.045) patients, with high body mass index (more than 30 kg/m2) (p < 0.001). Palatal (p = 0.004), tongue (p = 0.026) and lateral pharyngeal wall obstructions (p = 0.006) were associated with severe obstructive sleep apnoea. Multi-level obstruction is more prevalent in obstructive sleep apnoea and is associated with increased severity. Obstruction at certain anatomical levels contributes more towards obstructive sleep apnoea severity.

  15. Improving adherence to the Epic Beacon ambulatory workflow.

    PubMed

    Chackunkal, Ellen; Dhanapal Vogel, Vishnuprabha; Grycki, Meredith; Kostoff, Diana

    2017-06-01

    Computerized physician order entry has been shown to significantly improve chemotherapy safety by reducing the number of prescribing errors. Epic's Beacon Oncology Information System of computerized physician order entry and electronic medication administration was implemented in Henry Ford Health System's ambulatory oncology infusion centers on 9 November 2013. Since that time, compliance to the infusion workflow had not been assessed. The objective of this study was to optimize the current workflow and improve the compliance to this workflow in the ambulatory oncology setting. This study was a retrospective, quasi-experimental study which analyzed the composite workflow compliance rate of patient encounters from 9 to 23 November 2014. Based on this analysis, an intervention was identified and implemented in February 2015 to improve workflow compliance. The primary endpoint was to compare the composite compliance rate to the Beacon workflow before and after a pharmacy-initiated intervention. The intervention, which was education of infusion center staff, was initiated by ambulatory-based, oncology pharmacists and implemented by a multi-disciplinary team of pharmacists and nurses. The composite compliance rate was then reassessed for patient encounters from 2 to 13 March 2015 in order to analyze the effects of the determined intervention on compliance. The initial analysis in November 2014 revealed a composite compliance rate of 38%, and data analysis after the intervention revealed a statistically significant increase in the composite compliance rate to 83% ( p < 0.001). This study supports a pharmacist-initiated educational intervention can improve compliance to an ambulatory, oncology infusion workflow.

  16. Design of a K/Q-Band Beacon Receiver for the Alphasat TDP#5 Experiment

    NASA Technical Reports Server (NTRS)

    Morse, Jacquelynne R.

    2014-01-01

    This paper describes the design and performance of a coherent KQ-band (2040 GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload 5 (TDP5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40 GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58 dB at 1 Hz and better than 48 dB at 10 Hz rates.

  17. Design of a K/Q-band Beacon Receiver for the Alphasat TDP#5 Experiment

    NASA Technical Reports Server (NTRS)

    Nessel, James A.; Zemba, Michael J.; Morse, Jacquelynne R.

    2014-01-01

    This paper describes the design and performance of a coherent K/Q-band (20/40GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload #5 (TDP#5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58dB at 1Hz and better than 48dB at 10Hz rates.

  18. Visually Detecting the Variation of miR-301a Expression Using Gold Nanoparticle Beacon.

    PubMed

    Zhang, Ying; Li, Kai; Li, Dandan; Li, Changfeng; Zhang, Bin

    2018-02-01

    It is well known that microRNA-301a plays an important role in many diseases, as well as is overexpressed in human colon cancer and affects the process of tumorigenesis. Determination of the miR-301a expression provides insight into the mechanism of tumor progression. In this study, we designed a special hairpin deoxyribonucleic acid (DNA) for miR-301a to functionalize gold nanoparticles, which served as a beacon for detecting miR-301a expression. A-quenching efficiency up to 90% was achieved. The beacon we designed in this study can monitor the precise variation of miR-301a expression in vivo. The strategy reported in this study is a promising approach for the measurement of miRNA in living cells. Moreover, it has a great potential in the study of drug screening and discovery.

  19. Controller-reported performance defects in the air traffic control radar beacon system (1971 survey)

    DOT National Transportation Integrated Search

    1973-03-01

    This report analyzes the returns from a recent ATC performance survey initiated by the Beacon System Interference Problem Subgroup. The survey began on the 27 November 1971 and lasted for two weeks. Participatione was limited to 37 facilities with pr...

  20. X/X/Ka-band prime focus feed antenna for the Mars Observer beacon spacecraft

    NASA Technical Reports Server (NTRS)

    Stanton, P.; Reilly, H.; Esquivel, M.

    1988-01-01

    The results of an X/X/Ka-band feed design concept demonstration are presented. The purpose is to show the feasibility of adding a Ka-band beacon to the Mars Observer spacecraft. Scale model radiation patterns were made and analyzed.

  1. Application of a molecular beacon based real-time isothermal amplification (MBRTIA) technology for simultaneous detection of Bacillus cereus and Staphylococcus aureus.

    PubMed

    Mandappa, I M; Joglekar, Prasanna; Manonmani, H K

    2015-07-01

    A multiplex real-time isothermal amplification assay was developed using molecular beacons for the detection of Bacillus cereus and Staphylococcus aureus by targeting four important virulence genes. A correlation between targeting highly accessible DNA sequences and isothermal amplification based molecular beacon efficiency and sensitivity was demonstrated using phi(Φ)29 DNA polymerase at a constant isothermal temperature of 30 °C. It was very selective and consistently detected down to 10(1) copies of DNA. The specificity and sensitivity of this assay, when tested with pure culture were high, surpassing those of currently used PCR assays for the detection of these organisms. The molecular beacon based real-time isothermal amplification (MBRTIA) assay could be carried out entirely in 96 well plates or well strips, enabling a rapid and high-throughput detection of food borne pathogens.

  2. The New York City Beacons: Rebuilding Communities of Support in Urban Neighborhoods

    ERIC Educational Resources Information Center

    Kleinbard, Peter

    2005-01-01

    The first ten New York City Beacons began operation in 1991 as a result of the recommendation of a commission appointed by then-mayor David N. Dinkins. Richard Murphy, commissioner of youth services, led the development and implementation. Michele Cahill served as a consultant in the design and created the Youth Development Institute (YDI) as part…

  3. Making It Local: Beacon Communities Use Health Information Technology to Optimize Care Management

    PubMed Central

    Allen, Amy; Des Jardins, Terrisca R.; Heider, Arvela; Kanger, Chatrian R.; Lobach, David F.; McWilliams, Lee; Polello, Jennifer M.; Schachter, Abigail A.; Singh, Ranjit; Sorondo, Barbara; Tulikangas, Megan C.; Turske, Scott A.

    2014-01-01

    Abstract Care management aims to provide cost-effective, coordinated, non-duplicative care to improve care quality, population health, and reduce costs. The 17 communities receiving funding from the Office of the National Coordinator for Health Information Technology through the Beacon Community Cooperative Agreement Program are leaders in building and strengthening their health information technology (health IT) infrastructure to provide more effective and efficient care management. This article profiles 6 Beacon Communities' health IT-enabled care management programs, highlighting the influence of local context on program strategy and design, and describing challenges, lessons learned, and policy implications for care delivery and payment reform. The unique needs (eg, disease burden, demographics), community partnerships, and existing resources and infrastructure all exerted significant influence on the overall priorities and design of each community's care management program. Though each Beacon Community needed to engage in a similar set of care management tasks—including patient identification, stratification, and prioritization; intervention; patient engagement; and evaluation—the contextual factors helped shape the specific strategies and tools used to carry out these tasks and achieve their objectives. Although providers across the country are striving to deliver standardized, high-quality care, the diverse contexts in which this care is delivered significantly influence the priorities, strategies, and design of community-based care management interventions. Gaps and challenges in implementing effective community-based care management programs include: optimizing allocation of care management services; lack of available technology tailored to care management needs; lack of standards and interoperability; integrating care management into care settings; evaluating impact; and funding and sustainability. (Population Health Management 2014;17:149–158) PMID

  4. Creating a Connected Community: Lessons Learned from the Western New York Beacon Community

    PubMed Central

    Maloney, Nancy; Heider, Arvela R.; Rockwood, Amy; Singh, Ranjit

    2014-01-01

    Introduction: Secure exchange of clinical data among providers has the potential to improve quality, safety, efficiency, and reduce duplication. Many communities are experiencing challenges in building effective health information exchanges (HIEs). Previous studies have focused on financial and technical issues regarding HIE development. This paper describes the Western New York (WNY) HIE growth and lessons learned about accelerating progress to become a highly connected community. Methods: HEALTHeLINK, with funding from the Office of the National Coordinator for Health Information Technology (ONC) under the Beacon Community Program, expanded HIE usage in eight counties. The communitywide transformation process used three main drivers: (1) a communitywide Electronic Health Record (EHR) adoption program; (2) clinical transformation partners; and (3) HIE outreach and infrastructure development. Results: ONC Beacon Community funding allowed WNY to achieve a new level in the use of interoperable HIE. Electronic delivery of results into the EHR expanded from 23 practices in 2010 to 222 practices in 2013, a tenfold increase. There were more than 12.5 million results delivered electronically (HL7 messages) to 222 practices’ EHRs via the HIE in 2013. Use of a secure portal and Virtual Health Record (VHR) to access reports (those not delivered directly to the EHR) also increased significantly, from 13,344 report views in 2010 to over 600,000 in 2013. Discussion and Conclusion: The WNY Beacon successfully expanded the sharing of clinical information among different sources of data and providers, creating a highly connected community to improve the quality and continuity of care. Technical, organizational, and community lessons described in this paper should prove beneficial to others as they pursue efforts to create connected communities. PMID:25848618

  5. Achievements of ATS-6 beacon experiment over Indian sub-continent

    NASA Technical Reports Server (NTRS)

    Deshpande, M. R.; Rastogi, R. G.; Vats, H. O.; Sethia, G.; Chandra, H.; Davies, K.; Grubb, R. N.; Jones, J. E.

    1978-01-01

    The repositioning of the ATS-6 satellite at 34 deg E enabled the scientific community of India to use the satellite's radio beacon for ionospheric studies. Two scientific projects were undertaken. The objective of the first project was to map ionospheric electron content, range rate errors, traveling ionospheric phenomena, solar flare effect, and magnetic phenomena. The second project was aimed at studying geophysical phenomena associated with the equatorial electrojet. The principal results of these studies are described.

  6. Electroactive crown ester-Cu2+ complex with in-situ modification at molecular beacon probe serving as a facile electrochemical DNA biosensor for the detection of CaMV 35s.

    PubMed

    Zhan, Fengping; Liao, Xiaolei; Gao, Feng; Qiu, Weiwei; Wang, Qingxiang

    2017-06-15

    A novel electrochemical DNA biosensor has been facilely constructed by in-situ assembly of electroactive 4'-aminobenzo-18-crown-6-copper(II) complex (AbC-Cu 2+ ) on the free terminal of the hairpin-structured molecule beacon. The 3'-SH modified molecule beacon probe was first immobilized on the gold electrode (AuE) surface through self-assembly chemistry of Au-S bond. Then the crow ester of AbC was covalently coupled with 5'-COOH on the molecule beacon, and served as a platform to attach the Cu 2+ by coordination with ether bond (-O-) of the crown cycle. Thus, an electroactive molecule beacon-based biosensing interface was constructed. In comparison with conventional methods for preparation of electroactive molecule beacon, the approach presented in this work is much simpler, reagent- and labor-saving. Selectivity study shows that the in-situ fabricated electroactive molecule beacon remains excellent recognition ability of pristine molecule beacon probe to well differentiate various DNA fragments. The target DNA can be quantatively determined over the range from 0.10pM to 0.50nM. The detection limit of 0.060pM was estimated based on signal-to-noise ratio of 3. When the biosensor was applied for the detection cauliflower mosaic virus 35s (CaMV 35s) in soybean extraction samples, satisfactory results are achieved. This work opens a new strategy for facilely fabricating electrochemical sensing interface, which also shows great potential in aptasensor and immurosensor fabrication. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Mars approach navigation using Doppler and range measurements to surface beacons and orbiting spacecraft

    NASA Technical Reports Server (NTRS)

    Thurman, Sam W.; Estefan, Jeffrey A.

    1991-01-01

    Approximate analytical models are developed and used to construct an error covariance analysis for investigating the range of orbit determination accuracies which might be achieved for typical Mars approach trajectories. The sensitivity or orbit determination accuracy to beacon/orbiter position errors and to small spacecraft force modeling errors is also investigated. The results indicate that the orbit determination performance obtained from both Doppler and range data is a strong function of the inclination of the approach trajectory to the Martian equator, for surface beacons, and for orbiters, the inclination relative to the orbital plane. Large variations in performance were also observed for different approach velocity magnitudes; Doppler data in particular were found to perform poorly in determining the downtrack (along the direction of flight) component of spacecraft position. In addition, it was found that small spacecraft acceleration modeling errors can induce large errors in the Doppler-derived downtrack position estimate.

  8. Controlling the signal: Practical privacy protection of genomic data sharing through Beacon services.

    PubMed

    Wan, Zhiyu; Vorobeychik, Yevgeniy; Kantarcioglu, Murat; Malin, Bradley

    2017-07-26

    Genomic data is increasingly collected by a wide array of organizations. As such, there is a growing demand to make summary information about such collections available more widely. However, over the past decade, a series of investigations have shown that attacks, rooted in statistical inference methods, can be applied to discern the presence of a known individual's DNA sequence in the pool of subjects. Recently, it was shown that the Beacon Project of the Global Alliance for Genomics and Health, a web service for querying about the presence (or absence) of a specific allele, was vulnerable. The Integrating Data for Analysis, Anonymization, and Sharing (iDASH) Center modeled a track in their third Privacy Protection Challenge on how to mitigate the Beacon vulnerability. We developed the winning solution for this track. This paper describes our computational method to optimize the tradeoff between the utility and the privacy of the Beacon service. We generalize the genomic data sharing problem beyond that which was introduced in the iDASH Challenge to be more representative of real world scenarios to allow for a more comprehensive evaluation. We then conduct a sensitivity analysis of our method with respect to several state-of-the-art methods using a dataset of 400,000 positions in Chromosome 10 for 500 individuals from Phase 3 of the 1000 Genomes Project. All methods are evaluated for utility, privacy and efficiency. Our method achieves better performance than all state-of-the-art methods, irrespective of how key factors (e.g., the allele frequency in the population, the size of the pool and utility weights) change from the original parameters of the problem. We further illustrate that it is possible for our method to exhibit subpar performance under special cases of allele query sequences. However, we show our method can be extended to address this issue when the query sequence is fixed and known a priori to the data custodian, so that they may plan stage their

  9. Comparison of OLYMPUS beacon and radiometric attenuation measurements at Blacksburg, Virginia

    NASA Technical Reports Server (NTRS)

    Snider, J. B.; Jacobson, M. D.; Beeler, R. H.; Hazen, D. A.

    1991-01-01

    Measurements of attenuation of the 20 and 30 GHz beacons onboard the OLYMPUS satellite are compared to simultaneous observations of atmospheric attenuation by a multichannel microwave radiometer along the same path. Departures from high correlation between the two measurements are believed to be related to differences in antenna beamwidths. Mean equivalent zenith attenuations derived from the slant path data are compared to zenith observations made at previous locations.

  10. Direct detection of microRNAs using isothermal amplification and molecular beacon with excellent sensitivity and specificity

    NASA Astrophysics Data System (ADS)

    Zhang, Wancun; Zhang, Qi; Qian, Zhiyu; Gu, Yueqing

    2017-02-01

    MicroRNAs (miRNAs) play important roles in a wide range of biological processes, including proliferation, development, metabolism, immunological response, tumorigenesis, and viral infection. The detection of miRNAs is imperative for gaining a better understanding of the functions of these biomolecules and has great potential for the early diagnosis of human disease as well as the discovery of new drugs through the use of miRNAs as targets. In this article, we develop a highly sensitive, and specific miRNA assay based on the two-stage isothermal amplification reactions and molecular beacon. The two-stage isothermal amplification reactions involves two templates and two-stage amplification reactions under isothermal conditions. The first template enables the amplification of miRNA, and the second template enables the conversion of miRNA to the reporter oligonucleotide(Y). Importantly, different miRNAs can be converted to the same Y seperately, which can hybridize with the same set of molecular beacon to generate fluorescent signals. This assay is highly sensitive and specific with a detection limit of 1 fM and can even discriminate single-nucleotide differences. Moreover, in combination with the specific templates, this method can be applied for multiplex miRNA assay by simply using the same molecular beacon. This method has potential to become a promising miRNA quantification method in biomedical research and clinical diagnosis.

  11. Analysis of rocket beacon transmissions for computerized reconstruction of ionospheric densities

    NASA Technical Reports Server (NTRS)

    Bernhardt, P. A.; Huba, J. D.; Chaturvedi, P. K.; Fulford, J. A.; Forsyth, P. A.; Anderson, D. N.; Zalesak, S. T.

    1993-01-01

    Three methods are described to obtain ionospheric electron densities from transionospheric, rocket-beacon TEC data. First, when the line-of-sight from a ground receiver to the rocket beacon is tangent to the flight trajectory, the electron concentration can be obtained by differentiating the TEC with respect to the distance to the rocket. A similar method may be used to obtain the electron-density profile if the layer is horizontally stratified. Second, TEC data obtained during chemical release experiments may be interpreted with the aid of physical models of the disturbed ionosphere to yield spatial maps of the modified regions. Third, computerized tomography (CT) can be used to analyze TEC data obtained along a chain of ground-based receivers aligned along the plane of the rocket trajectory. CT analysis of TEC data is used to reconstruct a 2D image of a simulated equatorial plume. TEC data is computed for a linear chain of nine receivers with adjacent spacings of either 100 or 200 km. The simulation data are analyzed to provide an F region reconstruction on a grid with 15 x 15 km pixels. Ionospheric rocket tomography may also be applied to rocket-assisted measurements of amplitude and phase scintillations and airglow intensities.

  12. Analysis of space shuttle main engine data using Beacon-based exception analysis for multi-missions

    NASA Technical Reports Server (NTRS)

    Park, H.; Mackey, R.; James, M.; Zak, M.; Kynard, M.; Sebghati, J.; Greene, W.

    2002-01-01

    This paper describes analysis of the Space Shuttle Main Engine (SSME) sensor data using Beacon-based exception analysis for multimissions (BEAM), a new technology developed for sensor analysis and diagnostics in autonomous space systems by the Jet Propulsion Laboratory (JPL).

  13. Power sources for search and rescue 406 MHz beacons

    NASA Technical Reports Server (NTRS)

    Attia, Alan I.; Perrone, David E.

    1987-01-01

    The results of a study directed at the selection of a commercially available, safe, low cost, light weight and long storage life battery for search and rescue (Sarsat) 406 MHz emergency beacons are presented. In the course of this work, five electrochemical systems (lithium-manganese dioxide, lithium-carbon monofluoride, lithium-silver vanadium oxide, alkaline cells, and cadmium-mercuric oxide) were selected for limited experimental studies to determine their suitability for this application. Two safe, commercially available batteries (lithium-manganese dioxide and lithium-carbon monofluoride) which meet the near term requirements and several alternatives for the long term were identified.

  14. Beacon of Hope: The Promise of Early Head Start for America's Youngest Children

    ERIC Educational Resources Information Center

    Lombardi, Joan, Ed.; Bogle, Mary M., Ed.

    2005-01-01

    Between 1995 and 2004, Early Head Start (EHS) grew from 68 to more than 700 programs nationwide, serving more than 62,000 children and securing the program's reputation as a beacon of hope for the nation's low-income families with infants and toddlers. According to a comprehensive 5-year national evaluation of EHS, children who participated in…

  15. Enhanced Terminal Information Services (ETIS) Utilizing the Discrete Address Beacon System (DABS) Data Link - Concept Description

    DOT National Transportation Integrated Search

    1979-07-01

    This report describes a concept for providing enhanced terminal information services (ETIS) to aircraft utilizing the ground-air-ground data link capability of the Discrete Address Beacon System (DABS). ETIS is envisioned as an eventual replacement f...

  16. Performance of the NASA Beacon Receiver for the Alphasat Aldo Paraboni TDP5 Propagation Experiment

    NASA Technical Reports Server (NTRS)

    Nessel, James; Morse, Jacquelynne; Zemba, Michael; Riva, Carlo; Luini, Lorenzo

    2015-01-01

    NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 gigahertz band. NASA GRC has developed and installed a K/Q-band (20/40 gigahertz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 gigahertz signals broadcast from the Alphasat Aldo Paraboni Technology Demonstration Payload (TDP) no. 5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we describe the design and preliminary performance of the NASA propagation terminal, which has been installed and operating in Milan since June 2014. The receiver is based upon a validated Fast Fourier Transform (FFT) I/Q digital design approach utilized in other operational NASA propagation terminals, but has been modified to employ power measurement via a frequency estimation technique and to coherently track and measure the amplitude of the 20/40 gigahertz beacon signals. The system consists of a 1.2-meter K-band and a 0.6-meter Q-band Cassegrain reflector employing synchronous open-loop tracking to track the inclined orbit of the Alphasat satellite. An 8 hertz sampling rate is implemented to characterize scintillation effects, with a 1-hertz measurement bandwidth dynamic range of 45 decibels. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

  17. Preliminary Results of the NASA Beacon Receiver for Alphasat Aldo Paraboni TDP5 Propagation Experiment

    NASA Technical Reports Server (NTRS)

    Nessel, James; Morse, Jacquelynne; Zemba, Michael; Riva, Carlo; Luini, Lorenzo

    2014-01-01

    NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 GHz band. NASA GRC has developed and installed a K/Q-band (20/40 GHz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 GHz signals broadcast from the Alphasat Aldo Paraboni TDP#5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we describe the design and preliminary performance of the NASA propagation terminal, which has been installed and operating in Milan since May 2014. The receiver is based upon a validated Fast Fourier Transform (FFT) I/Q digital design approach utilized in other operational NASA propagation terminals, but has been modified to employ power measurement via a frequency estimation technique and to coherently track and measure the amplitude of the 20/40 GHz beacon signals. The system consists of a 1.2-m K-band and a 0.6-m Qband Cassegrain reflector employing synchronous open-loop tracking to track the inclined orbit of the Alphasat satellite. An 8 Hz sampling rate is implemented to characterize scintillation effects, with a 1-Hz measurement bandwidth dynamic range of 45 dB. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

  18. The CERTO Beacon on CASSIOPE/e-POP and Experiments Using High-Power HF Ionospheric Heaters

    NASA Astrophysics Data System (ADS)

    Siefring, Carl L.; Bernhardt, Paul A.; James, H. Gordon; Parris, Richard Todd

    2015-06-01

    A new Coherent Electromagnetic Radio Tomography (CERTO) beacon is on the CASSIOPE satellite and part of the enhanced-Polar Outflow Probe (e-POP) suite of scientific instruments. CERTO signals can be used to measure ionospheric Total Electron Content (TEC) and radio scintillations along propagation paths between CERTO and receivers. The combination of CERTO and the array of e-POP in-situ diagnostics form a powerful tool for studying ionospheric plasma processes that have not been previously possible. Of note, the combination CERTO and the Radio Receiver Instrument (RRI), a modern digital receiver, which measures between 10 Hz to 18 MHz in selectable bands allows for innovative High Frequency (HF) radio propagation experiments. The use of high-power HF ionospheric heating facilities for such experiments further allows for repeatable studies of a number of important plasma processes. The new CERTO beacon transmits un-modulated, phase-coherent waves at 150, 400, and 1067 MHz with either right-hand-circular or linear polarization and TEC is measured using either differential phase and/or Faraday rotation. With a linear array of CERTO receivers, TEC data can be used for tomographic imaging of the ionosphere yielding two-dimensional maps of the plasma below the satellite orbit. In addition, the three CERTO frequencies cover a wide range for determination of radio scintillation effects caused by diffraction from propagation through ionospheric irregularities. We will describe the CERTO beacon and several potential innovative experiments using HF heating facilities in conjunction with CERTO, the RRI and other e-POP instruments.

  19. BEACON: A Summary Framework to Overcome Potential Reimbursement Hurdles.

    PubMed

    Dunlop, William C N; Mullins, C Daniel; Pirk, Olaf; Goeree, Ron; Postma, Maarten J; Enstone, Ashley; Heron, Louise

    2016-10-01

    To provide a framework for addressing payers' criteria during the development of pharmaceuticals. A conceptual framework was presented to an international health economic expert panel for discussion. A structured literature search (from 2010 to May 2015), using the following databases in Ovid: Medline(®) and Medline(®) In-Process (PubMed), Embase (Ovid), EconLit (EBSCOhost) and the National Health Service Economic Evaluation Database (NHS EED), and a 'grey literature' search, were conducted to identify existing criteria from the payer perspective. The criteria assessed by existing frameworks and guidelines were collated; the most commonly reported criteria were considered for inclusion in the framework. A mnemonic was conceived as a memory aide to summarise these criteria. Overall, 41 publications were identified as potentially relevant to the objective. Following further screening, 26 were excluded upon full-text review on the basis of no framework presented (n = 13), redundancy (n = 11) or abstract only (n = 2). Frameworks that captured criteria developed for or utilised by the pharmaceutical industry (n = 5) and reimbursement guidance (n = 10) were reviewed. The most commonly identified criteria-unmet need/patient burden, safety, efficacy, quality-of-life outcomes, environment, evidence quality, budget impact and comparator-were incorporated into the summary framework. For ease of communication, the following mnemonic was developed: BEACON (Burden/target population, Environment, Affordability/value, Comparator, Outcomes, Number of studies/quality of evidence). The BEACON framework aims to capture the 'essence' of payer requirements by addressing the most commonly described criteria requested by payers regarding the introduction of a new pharmaceutical.

  20. Principles of quantitation of viral loads using nucleic acid sequence-based amplification in combination with homogeneous detection using molecular beacons.

    PubMed

    Weusten, Jos J A M; Carpay, Wim M; Oosterlaken, Tom A M; van Zuijlen, Martien C A; van de Wiel, Paul A

    2002-03-15

    For quantitative NASBA-based viral load assays using homogeneous detection with molecular beacons, such as the NucliSens EasyQ HIV-1 assay, a quantitation algorithm is required. During the amplification process there is a constant growth in the concentration of amplicons to which the beacon can bind while generating a fluorescence signal. The overall fluorescence curve contains kinetic information on both amplicon formation and beacon binding, but only the former is relevant for quantitation. In the current paper, mathematical modeling of the relevant processes is used to develop an equation describing the fluorescence curve as a function of the amplification time and the relevant kinetic parameters. This equation allows reconstruction of RNA formation, which is characterized by an exponential increase in concentrations as long as the primer concentrations are not rate limiting and by linear growth over time after the primer pool is depleted. During the linear growth phase, the actual quantitation is based on assessing the amplicon formation rate from the viral RNA relative to that from a fixed amount of calibrator RNA. The quantitation procedure has been successfully applied in the NucliSens EasyQ HIV-1 assay.

  1. Obstructed labour.

    PubMed

    Neilson, J P; Lavender, T; Quenby, S; Wray, S

    2003-01-01

    Obstructed labour is an important cause of maternal deaths in communities in which undernutrition in childhood is common resulting in small pelves in women, and in which there is no easy access to functioning health facilities with the capability of carrying out operative deliveries. Obstructed labour also causes significant maternal morbidity in the short term (notably infection) and long term (notably obstetric fistulas). Fetal death from asphyxia is also common. There are differences in the behaviour of the uterus during obstructed labour, depending on whether the woman has delivered previously. The pattern in primigravid women (typically diminishing contractility with risk of infection and fistula) may result from tissue acidosis, whereas in parous women, contractility may be maintained with the risk of uterine rupture. Ultimately, tackling the problem of obstructed labour will require universal adequate nutritional intake from childhood and the ability to access adequately equipped and staffed clinical facilities when problems arise in labour. These seem still rather distant aspirations. In the meantime, strategies should be implemented to encourage early recognition of prolonged labour and appropriate clinical responses. The sequelae of obstructed labour can be an enormous source of human misery and the prevention of obstetric fistulas, and skilled treatment if they do occur, are important priorities in regions where obstructed labour is still common.

  2. The Southeastern Minnesota Beacon Project for Community-driven Health Information Technology: Origins, Achievements, and Legacy

    PubMed Central

    Chute, Christopher G.; Hart, Lacey A.; Alexander, Alex K.; Jensen, Daniel W.

    2014-01-01

    Introduction: The Southeastern (SE) Minnesota Beacon organized all the health care providers, county public health organizations, and school districts in the deployment and integration of health information exchange (HIE) and targeted health communication around childhood asthma and diabetes. The community cooperated to establish a clinical data repository for all residents in the 11-county region. Through this community of practice approach that involved traditional and nontraditional providers, the SE Minnesota Beacon was able to realize unique applications of this technology. This manuscript overviews the associated organization and infrastructure of this community collaboration. Background: The Office of the National Coordinator for Health Information Technology (ONC), as part of the American Recovery and Reinvestment Act of 2009 (ARRA) stimulus, established 17 projects throughout the United States targeting the introduction and meaningful use of health information technology (HIT). These 17 communities were intended to serve as an example of what could be accomplished. The SE Minnesota Beacon is one of these communities. Methods: The community ultimately opted for peer-to-peer HIE, using Nationwide Health Information Network (NwHIN) Connect software. The clinical data repository was established using the infrastructure developed by the Regenstrief Institute, which operated as a trusted third party. As an extension to HIE, the consortium of county public health departments created a patient data portal for use by school nurses and parents. Childhood asthma was addressed by creating, exchanging, and maintaining an “asthma action plan” for each affected child, shared throughout the community, including through the patient portal. Diabetes management introduced patient treatment decision tools and patient quality of life measures, facilitating care. Influenza vaccination was enhanced by large-scale community reporting in partnership with the state vaccination

  3. The Southeastern Minnesota Beacon Project for Community-driven Health Information Technology: Origins, Achievements, and Legacy.

    PubMed

    Chute, Christopher G; Hart, Lacey A; Alexander, Alex K; Jensen, Daniel W

    2014-01-01

    The Southeastern (SE) Minnesota Beacon organized all the health care providers, county public health organizations, and school districts in the deployment and integration of health information exchange (HIE) and targeted health communication around childhood asthma and diabetes. The community cooperated to establish a clinical data repository for all residents in the 11-county region. Through this community of practice approach that involved traditional and nontraditional providers, the SE Minnesota Beacon was able to realize unique applications of this technology. This manuscript overviews the associated organization and infrastructure of this community collaboration. The Office of the National Coordinator for Health Information Technology (ONC), as part of the American Recovery and Reinvestment Act of 2009 (ARRA) stimulus, established 17 projects throughout the United States targeting the introduction and meaningful use of health information technology (HIT). These 17 communities were intended to serve as an example of what could be accomplished. The SE Minnesota Beacon is one of these communities. The community ultimately opted for peer-to-peer HIE, using Nationwide Health Information Network (NwHIN) Connect software. The clinical data repository was established using the infrastructure developed by the Regenstrief Institute, which operated as a trusted third party. As an extension to HIE, the consortium of county public health departments created a patient data portal for use by school nurses and parents. Childhood asthma was addressed by creating, exchanging, and maintaining an "asthma action plan" for each affected child, shared throughout the community, including through the patient portal. Diabetes management introduced patient treatment decision tools and patient quality of life measures, facilitating care. Influenza vaccination was enhanced by large-scale community reporting in partnership with the state vaccination registry. The methodology and

  4. Analysis of obstruction site in obstructive sleep apnea syndrome patients by drug induced sleep endoscopy.

    PubMed

    Koo, Soo Kweon; Choi, Jang Won; Myung, Nam Suk; Lee, Hyoung Ju; Kim, Yang Jae; Kim, Young Joong

    2013-01-01

    We analyzed site, pattern and degree of obstruction in Korean male obstructive sleep apnea syndrome (OSAS) patients by drug-induced sleep endoscopy (DISE). We also investigated possible links between BMI, AHI and DISE findings. Sixty-nine male patients underwent DISE. DISE findings were reported using our classification system in which modified 'VOTE classification' - obstruction type, site of obstruction, degree of obstruction and anatomical site contributing obstruction - was reported. Associations were analyzed among the results of the polysomnography, patients' characteristics and DISE finding. Multilevel airway obstruction was found in 84.06% of patients and 15.94% had a unilevel obstruction. Among those with unilevel obstruction, 90.90% had retropalatal level obstruction and 9.10% had retrolingual level obstruction. Palate with lateral pharyngeal wall obstruction (49.28%) is the most common obstruction type of the retropalatal level and tongue with lateral pharyngeal wall (37.68%) is the most common obstruction type of the retrolingual level. Examining the relation between obstruction site according to body mass index (BMI) and severity of OSAS (apnea hypopnea index, AHI), the lateral pharyngeal wall had an increasing tendency associated with higher BMI and higher AHI. But the lateral pharyngeal wall of both levels was statistically significant associated with higher AHI. The majority of the Korean male OSAS patients have multilevel obstruction and according to BMI and AHI, the DISE findings indicate that the lateral pharyngeal wall is the most important anatomical site contributing to obstruction regardless of the level at which the obstruction lies. © 2013 Elsevier Inc. All rights reserved.

  5. Design of a K/Q-Band Beacon Receiver for the Alphasat Technology Demonstration Payload (TDP) #5 Experiment

    NASA Technical Reports Server (NTRS)

    Morse, Jacquelynne R.

    2014-01-01

    This paper describes the design and performance of a coherent KQ-band (2040 GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload 5 (TDP5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40 GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58 dB at 1 Hz and better than 48 dB at 10 Hz rates.

  6. Conceptual development of a ground-based radio-beacon navigation system for use on the surface of the moon

    NASA Technical Reports Server (NTRS)

    Beggins, Andrew J.; Canney, Lora M.; Dolezal, Anna Belle

    1988-01-01

    A spread-spectrum radio-beacon navigation system for use on the lunar surface is described. The subjects discussed are principle of operation and specifications to include power requirements, operating frequencies, weight, size, and range.

  7. RNA-templated single-base mutation detection based on T4 DNA ligase and reverse molecular beacon.

    PubMed

    Tang, Hongxing; Yang, Xiaohai; Wang, Kemin; Tan, Weihong; Li, Huimin; He, Lifang; Liu, Bin

    2008-06-15

    A novel RNA-templated single-base mutation detection method based on T4 DNA ligase and reverse molecular beacon (rMB) has been developed and successfully applied to identification of single-base mutation in codon 273 of the p53 gene. The discrimination was carried out using allele-specific primers, which flanked the variable position in the target RNA and was ligated using T4 DNA ligase only when the primers perfectly matched the RNA template. The allele-specific primers also carried complementary stem structures with end-labels (fluorophore TAMRA, quencher DABCYL), which formed a molecular beacon after RNase H digestion. One-base mismatch can be discriminated by analyzing the change of fluorescence intensity before and after RNase H digestion. This method has several advantages for practical applications, such as direct discrimination of single-base mismatch of the RNA extracted from cell; no requirement of PCR amplification; performance of homogeneous detection; and easily design of detection probes.

  8. Palindromic Molecule Beacon-Based Cascade Amplification for Colorimetric Detection of Cancer Genes.

    PubMed

    Shen, Zhi-Fa; Li, Feng; Jiang, Yi-Fan; Chen, Chang; Xu, Huo; Li, Cong-Cong; Yang, Zhe; Wu, Zai-Sheng

    2018-03-06

    A highly sensitive and selective colorimetric assay based on a multifunctional molecular beacon with palindromic tail (PMB) was proposed for the detection of target p53 gene. The PMB probe can serve as recognition element, primer, and polymerization template and contains a nicking site and a C-rich region complementary to a DNAzyme. In the presence of target DNA, the hairpin of PMB is opened, and the released palindromic tails intermolecularly hybridize with each other, triggering the autonomous polymerization/nicking/displacement cycles. Although only one type of probe is involved, the system can execute triple and continuous polymerization strand displacement amplifications, generating large amounts of G-quadruplex fragments. These G-rich fragments can bind to hemin and form the DNAzymes that possess the catalytic activity similar to horseradish peroxidase, catalyzing the oxidation of ABTS by H 2 O 2 and producing the colorimetric signal. Utilizing the newly proposed sensing system, target DNA can be detected down to 10 pM with a linear response range from 10 pM to 200 nM, and mutant target DNAs are able to be distinguished even by the naked eye. The desirable detection sensitivity, high specificity, and operation convenience without any separation step and chemical modification demonstrate that the palindromic molecular beacon holds the potential for detecting and monitoring a variety of nucleic acid-related biomarkers.

  9. A Two-Layer Method for Sedentary Behaviors Classification Using Smartphone and Bluetooth Beacons.

    PubMed

    Cerón, Jesús D; López, Diego M; Hofmann, Christian

    2017-01-01

    Among the factors that outline the health of populations, person's lifestyle is the more important one. This work focuses on the caracterization and prevention of sedentary lifestyles. A sedentary behavior is defined as "any waking behavior characterized by an energy expenditure of 1.5 METs (Metabolic Equivalent) or less while in a sitting or reclining posture". To propose a method for sedentary behaviors classification using a smartphone and Bluetooth beacons considering different types of classification models: personal, hybrid or impersonal. Following the CRISP-DM methodology, a method based on a two-layer approach for the classification of sedentary behaviors is proposed. Using data collected from a smartphones' accelerometer, gyroscope and barometer; the first layer classifies between performing a sedentary behavior and not. The second layer of the method classifies the specific sedentary activity performed using only the smartphone's accelerometer and barometer data, but adding indoor location data, using Bluetooth Low Energy (BLE) beacons. To improve the precision of the classification, both layers implemented the Random Forest algorithm and the personal model. This study presents the first available method for the automatic classification of specific sedentary behaviors. The layered classification approach has the potential to improve processing, memory and energy consumption of mobile devices and wearables used.

  10. Secure Utilization of Beacons and UAVs in Emergency Response Systems for Building Fire Hazard.

    PubMed

    Seo, Seung-Hyun; Choi, Jung-In; Song, Jinseok

    2017-09-25

    An intelligent emergency system for hazard monitoring and building evacuation is a very important application area in Internet of Things (IoT) technology. Through the use of smart sensors, such a system can provide more vital and reliable information to first-responders and also reduce the incidents of false alarms. Several smart monitoring and warning systems do already exist, though they exhibit key weaknesses such as a limited monitoring coverage and security, which have not yet been sufficiently addressed. In this paper, we propose a monitoring and emergency response method for buildings by utilizing beacons and Unmanned Aerial Vehicles (UAVs) on an IoT security platform. In order to demonstrate the practicability of our method, we also implement a proof of concept prototype, which we call the UAV-EMOR (UAV-assisted Emergency Monitoring and Response) system. Our UAV-EMOR system provides the following novel features: (1) secure communications between UAVs, smart sensors, the control server and a smartphone app for security managers; (2) enhanced coordination between smart sensors and indoor/outdoor UAVs to expand real-time monitoring coverage; and (3) beacon-aided rescue and building evacuation.

  11. Secure Utilization of Beacons and UAVs in Emergency Response Systems for Building Fire Hazard

    PubMed Central

    Seo, Seung-Hyun; Choi, Jung-In; Song, Jinseok

    2017-01-01

    An intelligent emergency system for hazard monitoring and building evacuation is a very important application area in Internet of Things (IoT) technology. Through the use of smart sensors, such a system can provide more vital and reliable information to first-responders and also reduce the incidents of false alarms. Several smart monitoring and warning systems do already exist, though they exhibit key weaknesses such as a limited monitoring coverage and security, which have not yet been sufficiently addressed. In this paper, we propose a monitoring and emergency response method for buildings by utilizing beacons and Unmanned Aerial Vehicles (UAVs) on an IoT security platform. In order to demonstrate the practicability of our method, we also implement a proof of concept prototype, which we call the UAV-EMOR (UAV-assisted Emergency Monitoring and Response) system. Our UAV-EMOR system provides the following novel features: (1) secure communications between UAVs, smart sensors, the control server and a smartphone app for security managers; (2) enhanced coordination between smart sensors and indoor/outdoor UAVs to expand real-time monitoring coverage; and (3) beacon-aided rescue and building evacuation. PMID:28946659

  12. Characterization of Atmospheric Turbulence Effects Over 149 km Propagation Path using Multi-Wavelength Laser Beacons

    DTIC Science & Technology

    2010-09-01

    received beams (Fig. 2). Narrow bandpass filters were used to dedicate each subaperture to a specific wave from a single beacon. In this paper we...r , (6) where 1 1 ( )Mn n mmI M I − = = ∑ r is the aperture-average intensity for the nth frame. The index S in Eq. (6) denotes averaging over

  13. A gold nanoparticles-modified aptamer beacon for urinary adenosine detection based on structure-switching/fluorescence-"turning on" mechanism.

    PubMed

    Zhang, Jin-Quan; Wang, Yong-Sheng; Xue, Jin-Hua; He, Yan; Yang, Hui-Xian; Liang, Jun; Shi, Lin-Fei; Xiao, Xi-Lin

    2012-11-01

    A novel small molecule probe, aptamer beacon (AB), was introduced for adenosine (Ade) recognition and quantitative analysis. The Ade aptamer was engineered into an aptamer beacon by adding a gold nanoparticle-modified nucleotide sequence which is complementary to aptamer sequence (FDNA) at the 3'-end of FDNA. The fluorescence signal "turning on" was observed when AB was bound to Ade, which is attributed to a significant conformational change in AB from a FDNA/QDNA duplex to a FDNA-Ade complex. The Ade measurement was carried out in 20 mmol L(-1) Tris-HCl buffer solution of pH 7.4, ΔF signal linearly correlated with the concentration of Ade over the range of 2.0×10(-8) to 1.8×10(-6) mol L(-1). The limit of detection (LOD) for Ade is 6.0×10(-9) mol L(-1) with relative standard deviations (R.S.D) of 3.64-5.36%, and the recoveries were 98.6%, 100%, 102% (n=6), respectively. The present method has been successfully applied to determine Ade in human urine samples, and the obtained results were in good agreement with those obtained by the HPLC method. Our investigation shows that the unique properties of the AB could provide a promising potential for small molecules detection, and be benefit to extend the application of aptamer beacon technique. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Beacon: a web portal to high-quality mental health websites for use by health professionals and the public.

    PubMed

    Christensen, Helen; Murray, Kristen; Calear, Alison L; Bennett, Kylie; Bennett, Anthony; Griffiths, Kathleen M

    2010-06-07

    To describe the Beacon web portal, which lists and rates quality health websites, collects user characteristics and publishes user feedback; and to report summary data on Beacon's highest-rated (best evidence-based) sites for mental health. A systematic search was undertaken in February 2009 for potentially relevant websites through a review of research papers and a recently published book, an internet search of Open Directory Project medical categories, a review of material on a high-profile mental health portal, and a survey of international researchers. All sites were ranked on a 7-point scale from -1 to 5, with negative scores indicating evidence of no effect and scores of 2 or more indicating evidence of efficacy based on reports in the scientific literature. By March 2010, 183 sites had been identified, of which 122 focused on physical health or wellbeing, 40 targeted anxiety, and 23 targeted depression. Of the eight generalised anxiety disorder sites identified, four achieved ratings of 2 or above. Two social anxiety disorder sites achieved scores higher than 2. Ten panic disorder sites were identified, with three achieving ratings of 2 or above; and five post-traumatic stress disorder sites were identified, with two achieving ratings of 2 or above. Of the 23 identified depression sites, four achieved a rating of 2 or above. There are a number of high-quality mental health websites on the internet, and Beacon provides a portal to enable the wide dissemination of these resources.

  15. Studying the influence of stem composition in pH-sensitive molecular beacons onto their sensing properties.

    PubMed

    Dembska, Anna; Kierzek, Elzbieta; Juskowiak, Bernard

    2017-10-16

    Intracellular sensing using fluorescent molecular beacons is a potentially useful strategy for real-time, in vivo monitoring of important cellular events. This work is focused on evaluation of pyrene excimer signaling molecular beacons (MBs) for the monitoring of pH changes in vitro as well as inside living cells. The recognition element in our MB called pHSO (pH-sensitive oligonucleotide) is the loop enclosing cytosine-rich fragment that is able to form i-motif structure in a specific pH range. However, alteration of a sequence of the 6 base pairs containing stem of MB allowed the design of pHSO probes that exhibited different dynamic pH range and possessed slightly different transition midpoint between i-motif and open loop configuration. Moreover, this conformational transition was accompanied by spectral changes showing developed probes different pyrene excimer-monomer emission ratio triggered by pH changes. The potential of these MBs for intracellular pH sensing is demonstrated on the example of HeLa cells line. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Statistical results from the Virginia Tech propagation experiment using the Olympus 12, 20, and 30 GHz satellite beacons

    NASA Technical Reports Server (NTRS)

    Stutzman, Warren L.; Safaai-Jazi, A.; Pratt, Timothy; Nelson, B.; Laster, J.; Ajaz, H.

    1993-01-01

    Virginia Tech has performed a comprehensive propagation experiment using the Olympus satellite beacons at 12.5, 19.77, and 29.66 GHz (which we refer to as 12, 20, and 30 GHz). Four receive terminals were designed and constructed, one terminal at each frequency plus a portable one with 20 and 30 GHz receivers for microscale and scintillation studies. Total power radiometers were included in each terminal in order to set the clear air reference level for each beacon and also to predict path attenuation. More details on the equipment and the experiment design are found elsewhere. Statistical results for one year of data collection were analyzed. In addition, the following studies were performed: a microdiversity experiment in which two closely spaced 20 GHz receivers were used; a comparison of total power and Dicke switched radiometer measurements, frequency scaling of scintillations, and adaptive power control algorithm development. Statistical results are reported.

  17. Acute GI obstruction.

    PubMed

    Hucl, Tomas

    2013-10-01

    Acute gastrointestinal obstruction occurs when the normal flow of intestinal contents is interrupted. The blockage can occur at any level throughout the gastrointestinal tract. The clinical symptoms depend on the level and extent of obstruction. Various benign and malignant processes can produce acute gastrointestinal obstruction, which often represents a medical emergency because of the potential for bowel ischemia leading to perforation and peritonitis. Early recognition and appropriate treatment are thus essential. The typical clinical symptoms associated with obstruction include nausea, vomiting, dysphagia, abdominal pain and failure to pass bowel movements. Abdominal distention, tympany due to an air-filled stomach and high-pitched bowel sounds suggest the diagnosis. The diagnostic process involves imaging including radiography, ultrasonography, contrast fluoroscopy and computer tomography in less certain cases. In patients with uncomplicated obstruction, management is conservative, including fluid resuscitation, electrolyte replacement, intestinal decompression and bowel rest. In many cases, endoscopy may aid in both the diagnostic process and in therapy. Endoscopy can be used for bowel decompression, dilation of strictures or placement of self-expandable metal stents to restore the luminal flow either as a final treatment or to allow for a delay until elective surgical therapy. When gastrointestinal obstruction results in ischemia, perforation or peritonitis, emergency surgery is required. Copyright © 2013. Published by Elsevier Ltd.

  18. May Small Digital PZT And Radio Beacons Improve The LPhL For Future Lunar Missions?

    NASA Astrophysics Data System (ADS)

    Ping, Jinsong; Su, Xiaoli; Hanada, Hideo; Gusev, Alexandra; Li, Jinling; Shi, Xian; Liu, Qinghui

    2012-08-01

    LLR is the current unique precise method to measure the LPhL since the Apollo missions. After 40years observations, the measu ring error of LPhL amplitudes have been reduced to about a couple of tens milli-arcseconds. To improve the measuring precision of LPhL, the new ideas of digital PZT (ILOM) and radio beacons are suggested by researchers from Japan, Russia and China for up - coming lunar missions. To promote above ideas in these mission s, we developed a prototype PZT, proposed radio beacons on CE - 3/4 lunar landing missions and on Lunar - Glob/Resource lunar landing missions. We are also developing the small VLBI antennas in Russia and China to prepare the possible LPhL joint in - beam radio observation from later 2013 or earlier 2014. The analyzing work of simulations have been carried out. Additionally, the newly developed digital PZT technique will also be used on measuring the local or regional plume line variation, which has been recently noticed closely related to the volcano and earthquake activities on the Earth (See Li et al. and Yang et al. in this meeting).

  19. ATS-6 - Radio Beacon Experiment: The first years. [ionospheric and satellite-to-ground electron content

    NASA Technical Reports Server (NTRS)

    Davies, K.; Fritz, R. B.; Grubb, R. N.; Jones, J. E.

    1975-01-01

    The Radio Beacon Experiment aboard Applications Technology Satellite-6 (ATS-6) is designed to measure the total electron content and the ionospheric electron content between the satellite and ground. The spaceborne beacon transmits signals on frequencies of 40, 140, and 360 MHz with amplitude modulations of 1 MHz and/or 0.1 MHz for the measurement of modulation phase, Faraday rotation, and amplitude. The modulation phase delays are calibrated in the satellite and in the ground equipment, and the polarization of the emitted signals are predetermined by standard antenna range techniques. The design of the ATS-6 receiver in Boulder, Colorado, is discussed. The antennae are of the short backfire type described by Ehrenspeck (1967), with nominal gains of 13, 19, and 22 dB at 40, 140, and 360 MHz, respectively. Data recording and overall supervision of the receiver is carried out by a 16-bit minicomputer with 8 k of memory. Overall performance of the system is satisfactory. Sample data on the monthly median hourly values of the total electron content, plasmospheric content, and shape factor show distinct seasonal and diurnal variations.

  20. Temporal change of EIA asymmetry revealed by a beacon receiver network in Southeast Asia

    NASA Astrophysics Data System (ADS)

    Watthanasangmechai, Kornyanat; Yamamoto, Mamoru; Saito, Akinori; Maruyama, Takashi; Yokoyama, Tatsuhiro; Nishioka, Michi; Ishii, Mamoru

    2015-05-01

    To reveal the temporal change of the equatorial ionization anomaly (EIA) asymmetry, a multipoint satellite-ground beacon experiment was conducted along the meridional plane of the Thailand-Indonesia sector. The observation includes one station near the magnetic equator and four stations at off-equator latitudes. This is the first EIA asymmetry study with high spatial resolution using GNU Radio Beacon Receiver (GRBR) observations in Southeast Asia. GRBR-total electron contents (TECs) from 97 polar-orbit satellite passes in March 2012 were analyzed in this study. Successive passes captured rapid evolution of EIA asymmetry, especially during geomagnetic disturbances. The penetrating electric fields that occur during geomagnetic disturbed days are not the cause of the asymmetry. Instead, high background TEC associated with an intense electric field empowers the neutral wind to produce severe asymmetry of the EIA. Such rapid evolution of EIA asymmetry was not seen during nighttime, when meridional wind mainly controlled the asymmetric structures. Additional data are necessary to identify the source of the variations, i.e., atmospheric waves. Precisely capturing the locations of the crests and the evolution of the asymmetry enhances understanding of the temporal change of EIA asymmetry at the local scale and leads to a future local modeling for TEC prediction in Southeast Asia.

  1. Guiding Math Students to Campus Services: An Impact Evaluation of the Beacon Program at South Texas College

    ERIC Educational Resources Information Center

    Visher, Mary; Butcher, Kristin F.; Cerna, Oscar S.

    2011-01-01

    This research rigorously evaluates whether a low-cost intervention can improve students' performance in developmental math. The "Beacon Mentoring Program" was developed at South Texas College by professors, administrators, and staff at the college. Surveys of students revealed that many did not have someone on campus whom they felt they…

  2. A molecular beacon based on DNA-templated silver nanoclusters for the highly sensitive and selective multiplexed detection of virulence genes.

    PubMed

    Han, Dan; Wei, Chunying

    2018-05-01

    In this work, we develop a fluorescent molecular beacon based on the DNA-templated silver nanoclusters (DNA-Ag NCs). The skillfully designed molecular beacon can be conveniently used for detection of diverse virulence genes as long as the corresponding recognition sequences are embedded. Importantly, the constructed detection system allows simultaneous detection of multiple nucleic acids, which is attributed to non-overlapping emission spectra of the as-synthesized silver nanoclusters. Based on the target-induced fluorescence enhancement, three infectious disease-related genes HIV, H1N1, and H5N1 are detected, and the corresponding detection limits are 3.53, 0.12 and 3.95nM, respectively. This design allows specific, versatile and simultaneous detection of diverse targets with easy operation and low cost. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Within-breath respiratory impedance and airway obstruction in patients with chronic obstructive pulmonary disease.

    PubMed

    Silva, Karla Kristine Dames da; Faria, Alvaro Camilo Dias; Lopes, Agnaldo José; Melo, Pedro Lopes de

    2015-07-01

    Recent work has suggested that within-breath respiratory impedance measurements performed using the forced oscillation technique may help to noninvasively evaluate respiratory mechanics. We investigated the influence of airway obstruction on the within-breath forced oscillation technique in smokers and chronic obstructive pulmonary disease patients and evaluated the contribution of this analysis to the diagnosis of chronic obstructive pulmonary disease. Twenty healthy individuals and 20 smokers were assessed. The study also included 74 patients with stable chronic obstructive pulmonary disease. We evaluated the mean respiratory impedance (Zm) as well as values for the inspiration (Zi) and expiration cycles (Ze) at the beginning of inspiration (Zbi) and expiration (Zbe), respectively. The peak-to-peak impedance (Zpp=Zbe-Zbi) and the respiratory cycle dependence (ΔZrs=Ze-Zi) were also analyzed. The diagnostic utility was evaluated by investigating the sensitivity, the specificity and the area under the receiver operating characteristic curve. ClinicalTrials.gov: NCT01888705. Airway obstruction increased the within-breath respiratory impedance parameters that were significantly correlated with the spirometric indices of airway obstruction (R=-0.65, p<0.0001). In contrast to the control subjects and the smokers, the chronic obstructive pulmonary disease patients presented significant expiratory-inspiratory differences (p<0.002). The adverse effects of moderate airway obstruction were detected based on the Zpp with an accuracy of 83%. Additionally, abnormal effects in severe and very severe patients were detected based on the Zm, Zi, Ze, Zbe, Zpp and ΔZrs with a high degree of accuracy (>90%). We conclude the following: (1) chronic obstructive pulmonary disease introduces higher respiratory cycle dependence, (2) this increase is proportional to airway obstruction, and (3) the within-breath forced oscillation technique may provide novel parameters that facilitate the

  4. Intestinal Pseudo-Obstruction

    MedlinePlus

    ... condition as adults. Intestinal pseudo-obstruction may be acute, occurring suddenly and lasting a short time, or it may be chronic, or long lasting. Acute colonic pseudo-obstruction, also called Ogilvie syndrome or ...

  5. 75 FR 20364 - Public Buildings Service; Key Largo Beacon Annex Site; Key Largo, FL; Transfer of Property

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-19

    ... GENERAL SERVICES ADMINISTRATION [Wildlife Order 187; 4-D-FL-1218] Public Buildings Service; Key Largo Beacon Annex Site; Key Largo, FL; Transfer of Property Pursuant to section 2 of Public Law 537, 80th Congress, approved May 19, 1948 (16 U.S.C. 667c), notice is hereby given that: 1. The General...

  6. Beacon Charter School Needs a School: A Case of Capital Outlay of Charters in a Public District

    ERIC Educational Resources Information Center

    Wronowski, Meredith L.

    2017-01-01

    The case study presented below is a representation of a real-world, ongoing situation involving a public school district's capital outlay for charter schools within its boundaries. One particular charter, Beacon Charter School, was promised a permanent building by the public school district that also acts as its authorizer. However, recent events…

  7. Non-linear molecular pattern classification using molecular beacons with multiple targets.

    PubMed

    Lee, In-Hee; Lee, Seung Hwan; Park, Tai Hyun; Zhang, Byoung-Tak

    2013-12-01

    In vitro pattern classification has been highlighted as an important future application of DNA computing. Previous work has demonstrated the feasibility of linear classifiers using DNA-based molecular computing. However, complex tasks require non-linear classification capability. Here we design a molecular beacon that can interact with multiple targets and experimentally shows that its fluorescent signals form a complex radial-basis function, enabling it to be used as a building block for non-linear molecular classification in vitro. The proposed method was successfully applied to solving artificial and real-world classification problems: XOR and microRNA expression patterns. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Proceedings of the Symposium of the COSPAR Satellite Beacon Group on the Geophysical Use of Satellite Beacon Observations Held at Boston University on 1- 4 June 1976

    DTIC Science & Technology

    1976-06-04

    CAL, , ,-"E - ’ :’’, EO..... : Ao GAAOEHO - - - 2 ’£ - - o- ,/ .""’ CO / 2: i i ; ’ o ,* , - /% t, ’ 2. 0 4 H 20 22 2 LOC AL’’E HL I Figure 7 Figure 8...24 0 4 S 2 LOC ~~lL TIMEASAI LOCAL T0k (bt) Figure 9 Figure 10 (233 1241 (252 1307 1334 1441 k L T 2526 2501 2449 23 76 2261 2159 AL 22 29 40 &o 105...981-1206, 1975 [2] Barrett, L. OTropospheric irregularity effects on the 360 Hartmann, G.K. MHz ATS-6 Radio Beacon". Submitted for publics- Leo , R.L

  9. Development of a Molecular-Beacon Assay To Detect the G1896A Precore Mutation in Hepatitis B Virus-Infected Individuals

    PubMed Central

    Waltz, Therese L.; Marras, Salvatore; Rochford, Gemma; Nolan, John; Lee, Eugenia; Melegari, Margherita; Pollack, Henry

    2005-01-01

    The 1896 precore (PC) mutation is the most frequent cause of hepatitis B virus e-antigen (HBeAg)-negative chronic hepatitis B virus (HBV) infection. Detection of the 1896 PC mutation has application in studies monitoring antiviral therapy and the natural history of the disease. Identification of this mutation is usually performed by direct sequencing, which is both costly and laborious. The aim of this study was to develop a rapid, high-throughput assay to detect the 1896 PC mutation using real-time PCR and molecular-beacon technology. The assay was initially standardized on oligonucleotide targets and plasmids containing the wild-type (WT) and PC mutation and then tested on plasma samples from children with HBV DNA of >106 copies/ml. Nine individuals were HBeAg negative and suspected to harbor HBeAg mutations, while 12 children were HBeAg positive and selected as controls. Ninety percent (19 of 21) of plasma samples tested with molecular beacons were in complete agreement with sequencing results. The remaining 10% (2 of 21) of samples were identified as heterogeneous mixtures of WT and mutant virus by molecular beacons, though sequencing found only a homogeneous mutant in both cases. Overall, the 1896 PC mutation was detected by this assay in 55.5% of the children with HBeAg-negative infection. In summary, this assay is a rapid, sensitive, and specific technique that effectively discriminates WT from 1896 PC mutant HBV and may be useful in clinical and epidemiological studies. PMID:15634980

  10. Low and Mid-Latitude Ionospheric Irregularities Studies Using TEC and Radio Scintillation Data from the CITRIS Radio Beacon Receiver in Low-Earth-Orbit

    NASA Astrophysics Data System (ADS)

    Siefring, C. L.; Bernhardt, P. A.; Huba, J.; Krall, J.; Roddy, P. A.

    2009-12-01

    Unique data on ionospheric plasma irregularities from the Naval Research Laboratory (NRL) CITRIS (Scintillation and TEC Receiver in Space) instrument will be presented. CITRIS is a multi-band receiver that recorded TEC (Total Electron Content) and radio scintillations from Low-Earth Orbit (LEO) on STPSat1. The 555+/5 km altitude 35° inclination orbit covers low and mid-latitudes. The measurements require propagation from a transmitter to a receiver through the F-region plasma. CITRIS used both 1) satellite beacons in LEO, such as the NRL CERTO (Coherent Electromagnetic Radio TOmography) beacons and 2) the global network of ground-based DORIS (Doppler Orbitography and Radiopositioning Integrated by Satellite) beacons. The TEC measurements allow for tracking of ionospheric disturbances and irregularities while the measurements of scintillations can simultaneously characterize their effects. CITRIS was operated in a complementary fashion with the C/NOFS (Communication/Navigations Outages Forecasting System) satellite during most of its first year of operations. C/NOFS carries a three-frequency 150/400/1067 MHz CERTO beacon and is dedicated to the study of Spread-F. In the case of Spread-F, ionospheric irregularities start with large scale size density gradients (100s of km) and cascade through complex processes to short scale sizes (10s of meters). It is typically the 100m-1km scale features that harm communication and navigation systems through scintillations. A multi-sensor approach is needed to completely understand this complex system, such as, the combination of CITRIS remote radio sensing and C/NOFS in-situ data. Several types of irregularities have been studied including Spread-F and the newly discovered dawn-side depletions. Comparisons with the physics based SAMI3 model are being performed to help our understanding of the morphology of the irregularities.

  11. Evaluation of a rectangular rapid flashing beacon system at the Belmont Ridge Road and W&OD Trail mid-block crosswalk.

    DOT National Transportation Integrated Search

    2015-05-01

    On April 8, 2013, the Virginia Department of Transportation (VDOT) installed a Rectangular Rapid Flashing Beacon : (RRFB) system at Belmont Ridge Road in Loudoun County that included two units at the Washington and Old Dominion : (W&OD) Trail crossin...

  12. A NEW LOOK AT SPECIAL PROBLEMS, PROJECT BEACON--A PROJECT ADDRESSED TO THE NEEDS OF THE SOCIALLY DISADVANTAGED.

    ERIC Educational Resources Information Center

    FISHMAN, JOSHUA

    A GREAT NUMBER OF AMERICAN CHILDREN ARE GROWING UP IN SOCIALLY DEPRIVED SURROUNDINGS. THESE DEPRIVATIONS ARE REFLECTED IN LOWER EDUCATIONAL ACHIEVEMENT. TEACHERS SHOULD HAVE SPECIAL PREPARATION IN ORDER TO LESSEN THIS WASTE OF EDUCATIONAL POTENTIAL. PROJECT BEACON IS AN EFFORT TO INTRODUCE WITHIN THE PUBLIC SCHOOL SYSTEM A PERMANENT CORPS OF…

  13. The Child Development Training Consortium. A Status Report on the San Juan College AACJC-Kellogg Beacon College Project.

    ERIC Educational Resources Information Center

    Beers, C. David; Ott, Richard W.

    The Child Development Training Consortium, a Beacon College Project directed by San Juan College (SJC) is a collaborative effort of colleges and universities in New Mexico and Arizona. The consortium's major objective is to create child development training materials for community college faculty who teach "at-risk" Native American and…

  14. Reduced upper obstructions in N3 and increased lower obstructions in REM sleep stage detected with manometry.

    PubMed

    Wirth, Markus; Schramm, Juliane; Bautz, Maximilian; Hofauer, Benedikt; Edenharter, Günther; Ott, Armin; Heiser, Clemens

    2018-01-01

    In obstructive sleep apnea (OSA), airway obstruction occurs at different anatomic levels. The frequency and location of obstructions play a crucial role in the planning of surgical treatment. The aim of this study was to evaluate the pharyngeal obstruction levels in different sleep stages with manometry in OSA patients. In addition, the manometry results were compared with drug-induced sleep endoscopy (DISE). Forty-one patients with OSA received manometry measurements during one night of sleep. All patients were simultaneously evaluated with polysomnography. The frequency of obstructions in different sleep stages was assessed. Twenty patients were additionally studied with DISE. Obstruction levels detected with manometry were compared with DISE. The frequency of upper and to a lesser extent lower obstructions decreased in sleep stage N3. In rapid eye movement (REM) sleep, lower obstructions increased. The overall proportion of upper and lower obstructions detected with manometry corresponded with DISE in 13 of 20 cases. A significant change in the obstruction levels was detected with manometry in N3 and REM sleep. The reduction of both upper and to a lesser extent lower obstructions in N3 suggests more stable airways in slow-wave sleep. Relevant lower obstructions were not detected in DISE compared to manometry in 5 out of 20 examinations. This could be a potential reason for treatment failure of site-specific surgical OSA treatment when only performing DISE preoperatively. Therefore, manometry could be a useful complementary tool in the preoperative evaluation for OSA.

  15. Severity of Airflow Obstruction in Chronic Obstructive Pulmonary Disease (COPD): Proposal for a New Classification.

    PubMed

    Coton, Sonia; Vollmer, William M; Bateman, Eric; Marks, Guy B; Tan, Wan; Mejza, Filip; Juvekar, Sanjay; Janson, Christer; Mortimer, Kevin; P A, Mahesh; Buist, A Sonia; Burney, Peter G J

    2017-10-01

    Current classifications of Chronic Obstructive Pulmonary Disease (COPD) severity are complex and do not grade levels of obstruction. Obstruction is a simpler construct and independent of ethnicity. We constructed an index of obstruction severity based on the FEV 1 /FVC ratio, with cut-points dividing the Burden of Obstructive Lung Disease (BOLD) study population into four similarly sized strata to those created by the GOLD criteria that uses FEV 1 . We measured the agreement between classifications and the validity of the FEV 1 -based classification in identifying the level of obstruction as defined by the new groupings. We compared the strengths of association of each classification with quality of life (QoL), MRC dyspnoea score and the self-reported exacerbation rate. Agreement between classifications was only fair. FEV 1 -based criteria for moderate COPD identified only 79% of those with moderate obstruction and misclassified half of the participants with mild obstruction as having more severe COPD. Both scales were equally strongly associated with QoL, exertional dyspnoea and respiratory exacerbations. Severity assessed using the FEV 1 /FVC ratio is only in moderate agreement with the severity assessed using FEV 1 but is equally strongly associated with other outcomes. Severity assessed using the FEV 1 /FVC ratio is likely to be independent of ethnicity.

  16. Dual-channel detection of metallothioneins and mercury based on a mercury-mediated aptamer beacon using thymidine-mercury-thymidine complex as a quencher.

    PubMed

    Chen, Si-Han; Wang, Yong-Sheng; Chen, Yun-Sheng; Tang, Xian; Cao, Jin-Xiu; Li, Ming-Hui; Wang, Xiao-Feng; Zhu, Yu-Feng; Huang, Yan-Qin

    2015-01-01

    A novel dual-channel strategy for the detection of metallothioneins (MTs) and Hg(2+) has been developed based on a mercury-mediated aptamer beacon (MAB) using thymidine-mercury-thymidine complex as a quencher for the first time. In the presence of Hg(2+), the T-rich oligonucleotide with a 6-carboxyfluorescein (TRO-FAM) can form an aptamer beacon via the formation of T-Hg(2+)-T base pairs, which results in a fluorescence quenching of the sensing system owing to the fluorescence resonance energy transfer (FRET) from the fluorophore of FAM to the terminated T-Hg(2+)-T base pair. The addition of MTs into this solution leads to the disruption of the T-Hg(2+)-T complex, resulting in an increase of the fluorescent signal of the system. In the optimizing condition, ΔF was directly proportional to the concentrations ranging from 5.63 nM to 0.275 μM for MTs, and 14.2 nM to 0.30 μM for Hg(2+) with the detection limits of 1.69 nM and 4.28 nM, respectively. The proposed dual-channel method avoids the label steps of a quencher in common molecular beacon strategies, without tedious procedure or the requirement of sophisticated equipment, and is rapid, inexpensive and sensitive. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Nasal obstruction and human communication.

    PubMed

    Malinoff, R; Moreno, C

    1989-04-01

    Nasal obstruction may cause a variety of communication disorders, particularly in children. The effects of nasal obstruction on hearing, speech, language, and voice are examined. Methods for assessing the effects of nasal obstruction are delineated, and recommendations for therapeutic interventions are described.

  18. Primary obstructive megaureter.

    PubMed

    Sripathi, V; King, P A; Thomson, M R; Bogle, M S

    1991-07-01

    Twenty-three children with primary obstructive megaureters presented between 1978 and 1988 to the Princess Margaret Hospital for Children in Perth. Twenty-eight ureters were treated. Urinary infections were the presenting feature in 14 children. The obstructive segment was transvesically excised. Histopathologic examination of the distal, intramural ureter showed fibromuscular disarray with a relative increase in fibrous tissue and reduction of musculature in all specimens. Twenty-two ureters were tapered by excision and all 28 were reimplanted using an antireflux technique. Seventeen children were followed for an average of 3 years. Seven children showed renal growth, reduction in ureteric size by greater than 2 cm, improvement in glomerular filtration rate by more than 10%, no obstruction on reflux, and no infections in postoperative period. Four children showed all the above but suffered one or more infections after the operation. Of the remaining 6 children, 3 had postoperative obstruction and 3 had vesicoureteric reflux.

  19. The utah beacon experience: integrating quality improvement, health information technology, and practice facilitation to improve diabetes outcomes in small health care facilities.

    PubMed

    Tennison, Janet; Rajeev, Deepthi; Woolsey, Sarah; Black, Jeff; Oostema, Steven J; North, Christie

    2014-01-01

    The Utah Improving Care through Connectivity and Collaboration (IC3) Beacon community (2010-2013) was spearheaded by HealthInsight, a nonprofit, community-based organization. One of the main objectives of IC(3) was to improve health care provided to patients with diabetes in three Utah counties, collaborating with 21 independent smaller clinics and two large health care enterprises. This paper will focus on the use of health information technology (HIT) and practice facilitation to develop and implement new care processes to improve clinic workflow and ultimately improve patients' diabetes outcomes at 21 participating smaller, independent clinics. Early in the project, we learned that most of the 21 clinics did not have the resources needed to successfully implement quality improvement (QI) initiatives. IC(3) helped clinics effectively use data generated from their electronic health records (EHRs) to design and implement interventions to improve patients' diabetes outcomes. This close coupling of HIT, expert practice facilitation, and Learning Collaboratives was found to be especially valuable in clinics with limited resources. Through this process we learned that (1) an extensive readiness assessment improved clinic retention, (2) clinic champions were important for a successful collaboration, and (3) current EHR systems have limited functionality to assist in QI initiatives. In general, smaller, independent clinics lack knowledge and experience with QI and have limited HIT experience to improve patient care using electronic clinical data. Additionally, future projects like IC(3) Beacon will be instrumental in changing clinic culture so that QI is integrated into routine workflow. Our efforts led to significant changes in how practice staff optimized their EHRs to manage and improve diabetes care, while establishing the framework for sustainability. Some of the IC(3) Beacon practices are currently smoothly transitioning to new models of care such as Patient

  20. Design of a Combined Beacon Receiver and Digital Radiometer for 40 GHz Propagation Measurements at the Madrid Deep Space Communications Complex

    NASA Technical Reports Server (NTRS)

    Zemba, Michael J.; Nessel, James A.; Morabito, David D.

    2017-01-01

    NASA Glenn Research Center (GRC) and the Jet Propulsion Laboratory (JPL) have jointly developed an atmospheric propagation terminal to measure and characterize propagation phenomena at 40 GHz at the Madrid Deep Space Communications Complex (MDSCC) in Robledo de Chavela, Spain. The hybrid Q-band system combines a 40 GHz beacon receiver and digital radiometer into the same RF front-end and observes the 39.402 GHz beacon of the European Space Agencys Alphasat Aldo Paraboni TDP5 experiment. The goals of these measurements are to assist MDSCC mission operations as well as to contribute to the development and improvement of International Telecommunications Union (ITU) models for prediction of communications systems performance within the Q-band. Herein, we provide an overview of the system design, characterization, and plan of operations to commence at the MDSCC beginning in March 2017.

  1. Model-Based Localization and Tracking Using Bluetooth Low-Energy Beacons

    PubMed Central

    Cemgil, Ali Taylan

    2017-01-01

    We introduce a high precision localization and tracking method that makes use of cheap Bluetooth low-energy (BLE) beacons only. We track the position of a moving sensor by integrating highly unreliable and noisy BLE observations streaming from multiple locations. A novel aspect of our approach is the development of an observation model, specifically tailored for received signal strength indicator (RSSI) fingerprints: a combination based on the optimal transport model of Wasserstein distance. The tracking results of the entire system are compared with alternative baseline estimation methods, such as nearest neighboring fingerprints and an artificial neural network. Our results show that highly accurate estimation from noisy Bluetooth data is practically feasible with an observation model based on Wasserstein distance interpolation combined with the sequential Monte Carlo (SMC) method for tracking. PMID:29109375

  2. Model-Based Localization and Tracking Using Bluetooth Low-Energy Beacons.

    PubMed

    Daniş, F Serhan; Cemgil, Ali Taylan

    2017-10-29

    We introduce a high precision localization and tracking method that makes use of cheap Bluetooth low-energy (BLE) beacons only. We track the position of a moving sensor by integrating highly unreliable and noisy BLE observations streaming from multiple locations. A novel aspect of our approach is the development of an observation model, specifically tailored for received signal strength indicator (RSSI) fingerprints: a combination based on the optimal transport model of Wasserstein distance. The tracking results of the entire system are compared with alternative baseline estimation methods, such as nearest neighboring fingerprints and an artificial neural network. Our results show that highly accurate estimation from noisy Bluetooth data is practically feasible with an observation model based on Wasserstein distance interpolation combined with the sequential Monte Carlo (SMC) method for tracking.

  3. Molecular beacons for DNA binding proteins: an emerging technology for detection of DNA binding proteins and their ligands.

    PubMed

    Dummitt, Benjamin; Chang, Yie-Hwa

    2006-06-01

    Quantitation of the level or activity of specific proteins is one of the most commonly performed experiments in biomedical research. Protein detection has historically been difficult to adapt to high throughput platforms because of heavy reliance upon antibodies for protein detection. Molecular beacons for DNA binding proteins is a recently developed technology that attempts to overcome such limitations. Protein detection is accomplished using inexpensive, easy-to-synthesize oligonucleotides, accompanied by a fluorescence readout. Importantly, detection of the protein and reporting of the signal occur simultaneously, allowing for one-step protocols and increased potential for use in high throughput analysis. While the initial iteration of the technology allowed only for the detection of sequence-specific DNA binding proteins, more recent adaptations allow for the possibility of development of beacons for any protein, independent of native DNA binding activity. Here, we discuss the development of the technology, the mechanism of the reaction, and recent improvements and modifications made to improve the assay in terms of sensitivity, potential for multiplexing, and broad applicability.

  4. Development of a high-precision selenodetic coordinate system for the physical surface of the Moon based on LED beacons on its surface

    NASA Astrophysics Data System (ADS)

    Shirenin, A. M.; Mazurova, E. M.; Bagrov, A. V.

    2016-11-01

    The paper presents a mathematical algorithm for processing an array of angular measurements of light beacons on images of the lunar surface onboard a polar artificial lunar satellite (PALS) during the Luna-Glob mission and coordinate-time referencing of the PALS for the development of reference selenocentric coordinate systems. The algorithm makes it possible to obtain angular positions of point light beacons located on the surface of the Moon in selenocentric celestial coordinates. The operation of measurement systems that determine the position and orientation of the PALS during its active existence have been numerically simulated. Recommendations have been made for the optimal use of different types of measurements, including ground radio trajectory measurements, navigational star sensors based on the onboard star catalog, gyroscopic orientation systems, and space videos of the lunar surface.

  5. Evaluation of two techniques of partial urethral obstruction in the male rat model of bladder outlet obstruction.

    PubMed

    Melman, Arnold; Tar, Moses; Boczko, Judd; Christ, George; Leung, Albert C; Zhao, Weixin; Russell, Robert G

    2005-11-01

    To perform a comparison to determine which of two methods of partial urethral ligation produces the most consistent outcome and fewest side effects. Such a study has not been previously reported. Partial urethral ligation is a means of causing reproducible bladder outlet obstruction. In the male rat model, partial urethral obstruction can be performed either by perineal incision and bulbous urethral ligation or retropubic incision and midprostatic obstruction. Fifteen male Sprague-Dawley rats were studied. Five were selected for bulbous urethral obstruction through a perineal incision, five for midprostatic obstruction using a retropubic approach, and five for a sham operation through a perineal incision. The operative time was shorter and morbidity lower with the perineal approach compared with the retropubic approach. Inflammation or infection, or both, were seen in the prostate, bladder, proximal urethra, ureters, and kidneys in the rats in which a midprostatic obstruction was performed. The proximal urethra and prostate were mildly inflamed in those rats that underwent bulbous obstruction. Sham-operated rats exhibited mild prostatitis only. The perineal approach to the bulbous urethra is the method of choice for creating a partial urethral obstruction model of bladder outlet obstruction in the male rat.

  6. Correlation of soft palate length with velum obstruction and severity of obstructive sleep apnea syndrome.

    PubMed

    Lim, Ju-Shin; Lee, Jae Woo; Han, Chun; Kwon, Jang-Woo

    2018-06-01

    Our aim in this study was to analyze whether soft palate length and velum obstruction during sleep are correlated and to determine the effects of related parameters on obstructive sleep apnea syndrome (OSAS) severity. We used computed tomography to measure soft palate length and drug-induced sleep endoscopy (DISE) to evaluate velum obstruction severity. Patients also underwent polysomnography (PSG) for evaluation of OSAS severity. A retrospective cohort of 67 patients with OSAS treated between May 1st, 2013 and July 31st, 2016 was analyzed. Each patient underwent DISE, PSG, and computed tomography. Using DISE, velum obstruction was categorized by the VOTE classification method. Using computed tomography, soft palate length was measured as the length of the posterior nasal spine to the uvula. Correlations of velum obstruction in DISE and PSG parameters (obstructive apnea, hypopnea, apnea hypopnea index (AHI), respiratory effort related arousal (RERA), respiratory disturbance index (RDI), baseline SaO 2 , and minimum SaO 2 ) with soft palate length were also analyzed. Among the 67 patients, the average PNS-U length was 39.90±4.19mm. Length was significantly different by age but not by other demographic characteristics such as sex, past history, or BMI. DISE revealed a statistically significant difference of velum obstruction degree; the cutoff value for PNS-U was 39.47mm. The PSG results, obstructive apnea, AHI, RDI, baseline SaO 2 , and minimum SaO 2 were correlated with PNS-U length, while other results such as hypopnea and RERA showed no correlation. Analysis of soft palate length showed that increased PNS-U length was associated with higher rates of obstructive apnea, AHI, and RDI as assessed by PSG. In contrast, lower baseline SaO 2 and minimum SaO 2 values were seen by PSG; more severe velum obstruction was seen by DISE. We propose that when a soft palate is suspected in OSAS, computed tomography measurement of soft palate length is a valid method for

  7. First observations of large-scale wave structure and equatorial spread F using CERTO radio beacon on the C/NOFS satellite

    NASA Astrophysics Data System (ADS)

    Thampi, Smitha V.; Yamamoto, Mamoru; Tsunoda, Roland T.; Otsuka, Yuichi; Tsugawa, Takuya; Uemoto, Jyunpei; Ishii, Mamoru

    2009-09-01

    First observations of large-scale wave structure (LSWS) and the subsequent development of equatorial spread F (ESF), using total electron content (TEC) derived from the ground based reception of beacon signals from the CERTO (Coherent Electromagnetic Radio Tomography) radio beacon on board C/NOFS (Communications/Navigation Outage Forecasting System) satellite, are presented. Selected examples of TEC variations, using measurements made during January 2009 from Bac Lieu, Vietnam (9.2°N, 105.6°E geographic, 1.7°N magnetic dip latitude) are presented to illustrate two key findings: (1) LSWS appears to play a more important role in the development of ESF than the post-sunset rise (PSSR) of the F-layer, and (2) LSWS can appear well before E region sunset. Other findings, that LSWS does not have significant zonal drift in the initial stages of growth, and can have zonal wavelengths of several hundred kilometers, corroborate earlier reports.

  8. STEREO Space Weather and the Space Weather Beacon

    NASA Technical Reports Server (NTRS)

    Biesecker, D. A.; Webb, D F.; SaintCyr, O. C.

    2007-01-01

    The Solar Terrestrial Relations Observatory (STEREO) is first and foremost a solar and interplanetary research mission, with one of the natural applications being in the area of space weather. The obvious potential for space weather applications is so great that NOAA has worked to incorporate the real-time data into their forecast center as much as possible. A subset of the STEREO data will be continuously downlinked in a real-time broadcast mode, called the Space Weather Beacon. Within the research community there has been considerable interest in conducting space weather related research with STEREO. Some of this research is geared towards making an immediate impact while other work is still very much in the research domain. There are many areas where STEREO might contribute and we cannot predict where all the successes will come. Here we discuss how STEREO will contribute to space weather and many of the specific research projects proposed to address STEREO space weather issues. We also discuss some specific uses of the STEREO data in the NOAA Space Environment Center.

  9. Creating accessible science museums with user-activated environmental audio beacons (ping!).

    PubMed

    Landau, Steven; Wiener, William; Naghshineh, Koorosh; Giusti, Ellen

    2005-01-01

    In 2003, Touch Graphics Company carried out research on a new invention that promises to improve accessibility to science museums for visitors who are visually impaired. The system, nicknamed Ping!, allows users to navigate an exhibit area, listen to audio descriptions, and interact with exhibits using a cell phone-based interface. The system relies on computer telephony, and it incorporates a network of wireless environmental audio beacons that can be triggered by users wishing to travel to destinations they choose. User testing indicates that the system is effective, both as a way-finding tool and as a means of providing accessible information on museum content. Follow-up development projects will determine if this approach can be successfully implemented in other settings and for other user populations.

  10. Flight Validation of On-Demand Operations: The Deep Space One Beacon Monitor Operations Experiment

    NASA Technical Reports Server (NTRS)

    Wyatt, Jay; Sherwood, Rob; Sue, Miles; Szijjarto, John

    2000-01-01

    After a brief overview of the operational concept, this paper will provide a detailed description of the _as-flown_ flight software components, the DS1 experiment plan, and experiment results to date. Special emphasis will be given to experiment results and lessons learned since the basic system design has been previously reported. Mission scenarios where beacon operations is highly applicable will be described. Detailed cost savings estimates for a sample science mission will be provided as will cumulative savings that are possible over the next fifteen years of NASA missions.

  11. Chronic intestinal pseudo-obstruction.

    PubMed

    Gabbard, Scott L; Lacy, Brian E

    2013-06-01

    Chronic intestinal pseudo-obstruction (CIP) is a rare and serious disorder of the gastrointestinal (GI) tract characterized as a motility disorder with the primary defect of impaired peristalsis; symptoms are consistent with a bowel obstruction, although mechanical obstruction cannot be identified. CIP is classified as a neuropathy, myopathy, or mesenchymopathy; it is a neuropathic process in the majority of patients. The natural history of CIP is generally that of a progressive disorder, although occasional patients with secondary CIP note significant symptomatic improvement when the underlying disorder is identified and treated. Symptoms vary from patient to patient depending on the location of the luminal GI tract involved and the degree of involvement; however, the small intestine is nearly always involved. Common symptoms include dysphagia, gastroesophageal reflux, abdominal pain, nausea, vomiting, bloating, abdominal distension, constipation or diarrhea, and involuntary weight loss. Unfortunately, these symptoms are nonspecific, which can contribute to misdiagnosis or a delay in diagnosis and treatment. Since many of the symptoms and signs suggest a mechanical bowel obstruction, diagnostic tests typically focus on uncovering a mechanical obstruction, although routine tests do not identify an obstructive process. Nutrition supplementation is required for many patients with CIP due to symptoms of dysphagia, nausea, vomiting, and weight loss. This review discusses the epidemiology, etiology, pathogenesis, diagnosis, and treatment of patients with CIP, with an emphasis on nutrition assessment and treatment options for patients with nutrition compromise.

  12. Gallbladder Polyp Mimicking an Obstructive Calculus

    PubMed Central

    Bass, James; Fegelman, Ronald H.

    1978-01-01

    The second documented case of obstructing polyp of the gallbladder—an extremely rare lesion—is presented. Symptoms were indistinguishable from those of acute obstructive cholecystitis. The mechanism of obstruction is hypothesized. ImagesFigure 1 PMID:702555

  13. Flight Software Implementation of the Beacon Monitor Expreiment On the NASA New Millennium Deep Space 1 (DS-1) Mission

    NASA Technical Reports Server (NTRS)

    Foster, R.; Schlutsmeyer, A.

    1997-01-01

    A new technology that can lower the cost of mission operations on future spacecraft will be tested on the NASA New Millennium Deep Space 1 (DS-1) Mission. This technology, the Beacon Monitor Experiment (BMOX), can be used to reduce the Deep Space Network (DSN) tracking time and its associated costs on future missions.

  14. Detection of Candida species in pregnant Chinese women with a molecular beacon method.

    PubMed

    Zhai, Yanhong; Liu, Jing; Zhou, Li; Ji, Tongzhen; Meng, Lingxin; Gao, Yang; Liu, Ran; Wang, Xiao; Li, Lin; Lu, Binghuai; Cao, Zheng

    2018-04-20

    Candida pathogens are commonly found in women and can cause vulvovaginal candidiasis (VVC), whose infection rate is further increased during pregnancy. We aimed to study the Candida prevalence and strain distribution in pregnant Chinese women with a molecular beacon assay. From March 2016 to February 2017, a total of 993 pregnant women attending routine antenatal visits at the Beijing Obstetrics and Gynecology Hospital were enrolled. For Candida detection and identification, a unique molecular beacon assay was presented and compared with a traditional phenotypic method. Antifungal susceptibility was tested with the following agents: 5-flucytosine, amphotericin B, fluconazole, itraconazole and voriconazole. The prevalence of Candida was found to be 21.8 % when using the molecular method and 15.0 % when using the phenotypic method. The distribution of the Candida spp. was listed in order of decreasing prevalence: Candida albicans (79.8 %), Candida glabrata (13.5 %), Candida parapsilosis (3.7 %), Candida krusei (2.2 %) and Candida tropicalis (1.1 %). We found that 90.7 % of the Candida detection results were consistent between the molecular and the phenotypic methods. In the cases where the sequencing analyses for the Candida isolates resulted in inconsistent identification, the molecular method showed higher sensitivity than the phenotypic method (96.0 vs 64.6 %). C. albicans, C. glabrata and C. parapsilosis were essentially susceptible to all five antifungal agents tested, whereas C. tropicalis and C. krusei were susceptible to voriconazole and amphotericin B. By exhibiting good sensitivity and specificity, the molecular assay may offer a fast and accurate Candida screening platform for pregnant women.

  15. Coupling Molecular Beacons to Barcoded Metal Nanowires for Multiplexed, Sealed Chamber DNA Bioassays

    PubMed Central

    Stoermer, Rebecca L.; Cederquist, Kristin B.; McFarland, Sean K.; Sha, Michael Y.; Penn, Sharron G.

    2010-01-01

    We have combined molecular beacon (MB) probes with barcoded metal nanowires to enable no-wash, sealed chamber, multiplexed detection of nucleic acids. Probe design and experimental parameters important in nanowire-based MB assays are discussed. Loop regions of 24 bases and 5 base pair stem regions in the beacon probes gave optimal performance. Our results suggest that thermodynamic predictions for secondary structure stability of solution-phase MB can guide probe design for nanowire-based assays. Dengue virus-specific probes with predicted solution-phase ΔG of folding in 500 mM buffered NaCl of approximately −4 kcal/mol performed better than those with ΔG > −2 or < −6 kcal/mol. Buffered 300–500 mM NaCl was selected after comparison of several buffers previously reported for similar types of assays, and 200–500 mM NaCl was found to be the optimal ionic strength for the hybridization temperatures (25 and 50 °C) and probe designs used here. Target binding to the surface as a function of solution concentration fit a Sips isotherm with Kd = 1.7 ± 0.3 nM. The detection limit was ∼100 pM, limited by incomplete quenching. Single base mismatches could be discriminated from fully complementary targets. Oligonucleotide target sequences specific for human immunodeficiency, hepatitis C, and severe acute respiratory viruses were assayed simultaneously in a no-wash, sealed chamber, multiplexed experiment in which each of three probe sequences was attached to a different pattern of encoded nanowires. Finally, we demonstrated that probe-coated nanowires retain their selectivity and sensitivity in a triplexed assay after storage for over 3 months. PMID:17177440

  16. Post-obstructive pulmonary edema from aspirated nuts.

    PubMed

    Bashir, Ahsan; Ahmad, Sabina Qureshi; Silverman, Joshua; Concepcion, Emily; Lee, Haesoon

    2017-01-01

    Post-obstructive pulmonary edema is thought to occur from hemodynamic changes secondary to forced inspiration against the closed airway due to acute or chronic airway obstruction. We report a case of a 13 month-old boy who developed pulmonary edema from aspirated foreign body, nuts. He underwent emergency bronchoscopy to confirm the clinical diagnosis of aspirated nuts in the trachea and nuts were removed endoscopically. His trachea was then intubated and he was mechanically ventilated with oxygen. He developed florid pulmonary edema early in the course with tracheal obstruction and during endoscopic removal of nuts. After removal of obstruction he was ventilated mechanically and pulmonary edema cleared rapidly. Aspirated nuts obstructing trachea can induce obstructive pulmonary edema. Early recognition of foreign body obstruction based on clinical history and its removal resolved pulmonary edema.

  17. The Fate of Nephrons in Congenital Obstructive Nephropathy: Adult Recovery is Limited by Nephron Number Despite Early Release of Obstruction.

    PubMed

    Sergio, Maria; Galarreta, Carolina I; Thornhill, Barbara A; Forbes, Michael S; Chevalier, Robert L

    2015-11-01

    Urinary tract obstruction and reduced nephron number often occur together as a result of maldevelopment of the kidneys and the urinary tract. We determined the role of nephron number on adaptation of the remaining nephrons of mice subjected to neonatal partial unilateral ureteral obstruction followed through adulthood. Wild-type and Os/+ mice (the latter with 50% fewer nephrons) underwent sham operation or partial unilateral ureteral obstruction in the first 2 days of life. Additional mice underwent release of unilateral ureteral obstruction at 7 days. All kidneys were harvested at 3 weeks (weaning) or 6 weeks (adulthood). Glomerular number and area, glomerulotubular junction integrity, proximal tubular volume fraction and interstitial fibrosis were measured by histomorphometry. In the obstructed kidney unilateral ureteral obstruction caused additional nephron loss in Os/+ but not in wild-type mice. Glomerular growth from 3 to 6 weeks was impaired by ipsilateral obstruction and not preserved by release in wild-type or Os/+ mice. Proximal tubular growth was impaired and interstitial collagen was increased by ipsilateral obstruction in all mice. These conditions were attenuated by release of unilateral ureteral obstruction in wild-type mice but were not restored in Os/+ mice. Unilateral ureteral obstruction increased interstitial collagen in the contralateral kidney while release of obstruction enhanced tubular growth and reduced interstitial collagen. Unilateral ureteral obstruction in early postnatal development impairs adaptation to reduced nephron number and induces additional nephron loss despite release of obstruction. Premature and low birth weight infants with congenital obstructive nephropathy are likely at increased risk for progression of chronic kidney disease. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. The Utah Beacon Experience: Integrating Quality Improvement, Health Information Technology, and Practice Facilitation to Improve Diabetes Outcomes in Small Health Care Facilities

    PubMed Central

    Tennison, Janet; Rajeev, Deepthi; Woolsey, Sarah; Black, Jeff; Oostema, Steven J.; North, Christie

    2014-01-01

    Purpose: The Utah Improving Care through Connectivity and Collaboration (IC3) Beacon community (2010–2013) was spearheaded by HealthInsight, a nonprofit, community-based organization. One of the main objectives of IC3 was to improve health care provided to patients with diabetes in three Utah counties, collaborating with 21 independent smaller clinics and two large health care enterprises. This paper will focus on the use of health information technology (HIT) and practice facilitation to develop and implement new care processes to improve clinic workflow and ultimately improve patients’ diabetes outcomes at 21 participating smaller, independent clinics. Innovation: Early in the project, we learned that most of the 21 clinics did not have the resources needed to successfully implement quality improvement (QI) initiatives. IC3 helped clinics effectively use data generated from their electronic health records (EHRs) to design and implement interventions to improve patients’ diabetes outcomes. This close coupling of HIT, expert practice facilitation, and Learning Collaboratives was found to be especially valuable in clinics with limited resources. Findings: Through this process we learned that (1) an extensive readiness assessment improved clinic retention, (2) clinic champions were important for a successful collaboration, and (3) current EHR systems have limited functionality to assist in QI initiatives. In general, smaller, independent clinics lack knowledge and experience with QI and have limited HIT experience to improve patient care using electronic clinical data. Additionally, future projects like IC3 Beacon will be instrumental in changing clinic culture so that QI is integrated into routine workflow. Conclusion and Discussion: Our efforts led to significant changes in how practice staff optimized their EHRs to manage and improve diabetes care, while establishing the framework for sustainability. Some of the IC3 Beacon practices are currently smoothly

  19. Postradiation ureteral obstruction: a reappraisal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muram, D.; Oxorn, H.; Curry, R.H.

    1981-02-01

    Thirty-four patients who received radiation therapy for carcinoma of the cervix developed hydronephrosis. Twelve of 34 (35%) had no evidence of pelvic malignancy, and the obstruction was caused by periureteral fibrosis. The incidence of obstructive uropathy due to periureteral fibrosis not associated with recurrent tumor increased when the obstructing lesion was unilateral, the clinical staging of the cervical carcinoma prior to therapy was Stage IB or Stage II rather than Stage III or Stage IV, and the obstructing lesion appeared 2 or more years after the completion of radiation therapy. The appearance of hydronephrosis in association with ipsilateral leg edema,more » and sciatic pain in these patients strongly suggest a recurrent tumor. The diagnosis of periureteral fibrosis should be considered in all patients who develop obstruction of the urinary tract after radiation therapy for carcinoma of the cervix. Laparotomy is indicated if all other methods of investigation fail to confirm the presence of a malignant lesion.« less

  20. Facile conversion of ATP-binding RNA aptamer to quencher-free molecular aptamer beacon.

    PubMed

    Park, Yoojin; Nim-Anussornkul, Duangrat; Vilaivan, Tirayut; Morii, Takashi; Kim, Byeang Hyean

    2018-01-15

    We have developed RNA-based quencher-free molecular aptamer beacons (RNA-based QF-MABs) for the detection of ATP, taking advantage of the conformational changes associated with ATP binding to the ATP-binding RNA aptamer. The RNA aptamer, with its well-defined structure, was readily converted to the fluorescence sensors by incorporating a fluorophore into the loop region of the hairpin structure. These RNA-based QF-MABs exhibited fluorescence signals in the presence of ATP relative to their low background signals in the absence of ATP. The fluorescence emission intensity increased upon formation of a RNA-based QF-MAB·ATP complex. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Surgical management of nasal obstruction.

    PubMed

    Moche, Jason A; Palmer, Orville

    2012-05-01

    The proper evaluation of the patient with nasal obstruction relies on a comprehensive history and physical examination. Once the site of obstruction is accurately identified, the patient may benefit from a trial of medical management. At times however, the definitive treatment of nasal obstruction relies on surgical management. Recognizing the nasal septum, nasal valve, and turbinates as possible sites of obstruction and addressing them accordingly can dramatically improve a patient's nasal breathing. Conservative resection of septal cartilage, submucous reduction of the inferior turbinate, and structural grafting of the nasal valve when appropriate will provide the optimal improvement in nasal airflow and allow for the most stable results. Copyright © 2012. Published by Elsevier Inc.

  2. Central Airway Obstruction: Benign Strictures, Tracheobronchomalacia, and Malignancy-related Obstruction.

    PubMed

    Murgu, Septimiu Dan; Egressy, Katarine; Laxmanan, Balaji; Doblare, Guillermo; Ortiz-Comino, Rosamaria; Hogarth, D Kyle

    2016-08-01

    The purpose of this article is to provide an update on methods for palliating symptoms in patients with histologically benign and malignant central airway obstruction. We review the published literature within the past decade on postintubation, posttracheostomy, and TB- and transplant-related airway strictures; tracheobronchomalacia; and malignant airway obstruction. We review terminology, classification systems, and parameters that impact treatment decisions. The focus is on how airway stent insertion fits into the best algorithm of care. Several case series and cohort studies demonstrate that airway stents improve dyspnea, lung function, and quality of life in patients with airway obstruction. Airway stenting, however, is associated with high rates of adverse events and should be used only when curative open surgical interventions are not feasible or are contraindicated. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  3. Screening mTOR siRNA based on bioinformatics and detecting the transcription by the gold nanoparticle beacon

    NASA Astrophysics Data System (ADS)

    Tian, Caiping; Ma, Yi; Li, Siwen; Gu, Yueqing

    2014-09-01

    Mammalian target of rapamycin (mTOR) as a key protein in PI3K-AKT-mTOR signaling pathway ,plays an important role in the tumor growth. The small interfering RNA (siRNA) of mTOR would decrease the expression of mTOR protein. In this study, we screened the mTOR siRNA sequence using MATLAB software and ascertained it based on BLAST. Then we imported it with the aid of Lipofectamine2000 into MCF-7 cancer cells where mTOR is over expression .And then we used a special hairpin deoxyribonucleic acid (DNA) for combining with the human mTOR mRNA to functionalize gold nanoparticles, which served as a molecule beacon for detecting human mTOR mRNA transcription. Laser scanning confocal microscope and Flow Cytometry data showed that the quenching efficiency was up to 90%,which are consistent with the RT-PCR measurement and Western. Compared to the previous approaches, this beacon has advantages of higher target to background ratio of detection. The strategy reported in this study is a promising approach for the intracellular measurement of the result of siRNA or protein expression in living cells, and has great potential in the study of drug screening and discovery.

  4. Rapid and amplification-free detection of fish pathogens by utilizing a molecular beacon-based microfluidic system.

    PubMed

    Su, Yi-Chih; Wang, Chih-Hung; Chang, Wen-Hsin; Chen, Tzong-Yueh; Lee, Gwo-Bin

    2015-01-15

    Nervous necrosis virus (NNV) and iridovirus are highly infectious pathogens that can cause lethal diseases in various species of fish. These infectious diseases have no effective treatments and the mortality rate is over 80%, which could cause dramatic economic losses in the aquaculture industry. Conventional diagnostic methods of NNV or iridovirus infected fishes, such as virus culture, enzyme-linked immunosorbent assays and nucleic acid assays usually require time-consuming and complex procedures performed by specialized technicians with delicate laboratory facilities. Rapid, simple, accurate and on-site detection of NNV and iridovirus infections would enable timely preventive measures such as immediate sacrifice of infected fishes, and is therefore critically needed for the aquaculture industry. In this study, a microfluidic-based assay that employ magnetic beads conjugated with viral deoxyribonucleic acid (DNA) capturing probes and fluorescent DNA molecular beacons were developed to rapidly detect NNV and iridovirus. Importantly, this new assay was realized in an integrated microfluidic system with a custom-made control system. With this approach, direct and automated NNV and iridovirus detection from infected fishes can be achieved in less than 30 min. Therefore, this molecular-beacon based microfluidic system presents a potentially promising tool for rapid diagnosis of fish pathogens in the field in the future. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Microscopic hematuria and calculus-related ureteral obstruction.

    PubMed

    Stewart, D P; Kowalski, R; Wong, P; Krome, R

    1990-01-01

    The evaluation of patients with ureteral calculi in the emergency department has historically included urinalysis (UA) and intravenous pyelograms (IVP). This retrospective study was done to determine if a statistically significant relationship existed between the degree of calculus-related ureteral obstruction, proven by IVP, and the presence or absence of microscopic hematuria. Urine red blood cells were recorded as less than 3 rbc/hpf (negative) or greater than or equal to 3 rbc/hpf (positive). IVPs were recorded as nonsevere or severe. IVP criteria were based on the presence or absence of extravasation, greater than 2-hour ureteral filling times, and a numerical scoring system of 1 to 4 for ureteral or calyceal dilatation and nephrogenic effect. Eighty-nine men (72%) had non-severe obstructions and 34 (28%) had severe obstructions. Twenty-five women (68%) had nonsevere obstructions and 12 (32%) had severe obstructions. Of the 28 patients with normal UAs, 11 had severe ureteral obstructions and 17 had nonsevere ureteral obstructions. There were no statistically significant differences between the presence or absence of significant microscopic hematuria and the presence or absence of severe ureteral obstruction. Microscopic hematuria is neither sensitive nor specific in determining the degree of calculus-related ureteral obstruction.

  6. Snoring Sounds Predict Obstruction Sites and Surgical Response in Patients with Obstructive Sleep Apnea Hypopnea Syndrome

    PubMed Central

    Lee, Li-Ang; Lo, Yu-Lun; Yu, Jen-Fang; Lee, Gui-She; Ni, Yung-Lun; Chen, Ning-Hung; Fang, Tuan-Jen; Huang, Chung-Guei; Cheng, Wen-Nuan; Li, Hsueh-Yu

    2016-01-01

    Snoring sounds generated by different vibrators of the upper airway may be useful indicators of obstruction sites in patients with obstructive sleep apnea hypopnea syndrome (OSAHS). This study aimed to investigate associations between snoring sounds, obstruction sites, and surgical responses (≥50% reduction in the apnea-hypopnea index [AHI] and <10 events/hour) in patients with OSAHS. This prospective cohort study recruited 36 OSAHS patients for 6-hour snoring sound recordings during in-lab full-night polysomnography, drug-induced sleep endoscopy (DISE), and relocation pharyngoplasty. All patients received follow-up polysomnography after 6 months. Fifteen (42%) patients with at least two complete obstruction sites defined by DISE were significantly, positively associated with maximal snoring sound intensity (40–300 Hz; odds ratio [OR], 1.25, 95% confidence interval [CI] 1.05–1.49) and body mass index (OR, 1.48, 95% CI 1.02–2.15) after logistic regression analysis. Tonsil obstruction was significantly, inversely correlated with mean snoring sound intensity (301–850 Hz; OR, 0.84, 95% CI 0.74–0.96). Moreover, baseline tonsil obstruction detected by either DISE or mean snoring sound intensity (301–850 Hz), and AHI could significantly predict the surgical response. Our findings suggest that snoring sound detection may be helpful in determining obstruction sites and predict surgical responses. PMID:27471038

  7. Baseline characteristics in the Bardoxolone methyl EvAluation in patients with Chronic kidney disease and type 2 diabetes mellitus: the Occurrence of renal eveNts (BEACON) trial.

    PubMed

    Lambers Heerspink, Hiddo J; Chertow, Glenn M; Akizawa, Tadao; Audhya, Paul; Bakris, George L; Goldsberry, Angie; Krauth, Melissa; Linde, Peter; McMurray, John J; Meyer, Colin J; Parving, Hans-Henrik; Remuzzi, Giuseppe; Christ-Schmidt, Heidi; Toto, Robert D; Vaziri, Nosratola D; Wanner, Christoph; Wittes, Janet; Wrolstad, Danielle; de Zeeuw, Dick

    2013-11-01

    Type 2 diabetes mellitus (T2DM) is the most important contributing cause of end-stage renal disease (ESRD) worldwide. Bardoxolone methyl, a nuclear factor-erythroid-2-related factor 2 activator, augments estimated glomerular filtration. The Bardoxolone methyl EvAluation in patients with Chronic kidney disease and type 2 diabetes mellitus: the Occurrence of renal eveNts (BEACON) trial was designed to establish whether bardoxolone methyl slows or prevents progression to ESRD. Herein, we describe baseline characteristics of the BEACON population. BEACON is a randomized double-blind placebo-controlled clinical trial in 2185 patients with T2DM and chronic kidney disease stage 4 (eGFR between 15 and 30 mL/min/1.73 m(2)) designed to test the hypothesis that bardoxolone methyl added to guideline-recommended treatment including inhibitors of the renin-angiotensin-aldosterone system slows or prevents progression to ESRD or cardiovascular death compared with placebo. Baseline characteristics (mean or percentage) of the population include age 68.5 years, female 43%, Caucasian 78%, eGFR 22.5 mL/min/1.73 m(2) and systolic/diastolic blood pressure 140/70 mmHg. The median urinary albumin:creatinine ratio was 320 mg/g and the frequency of micro- and macroalbuminuria was 30 and 51%, respectively. Anemia, abnormalities in markers of bone metabolism and elevations in cardiovascular biomarkers were frequently observed. A history of cardiovascular disease was present in 56%, neuropathy in 47% and retinopathy in 41% of patients. The BEACON trial enrolled a population heretofore unstudied in an international randomized controlled trial. Enrolled patients suffered with numerous co-morbid conditions and exhibited multiple laboratory abnormalities, highlighting the critical need for new therapies to optimize management of these conditions.

  8. [A case of gastric outlet obstruction and rectal obstruction due to metastases from breast cancer treated by gastroduodenal and colon stenting].

    PubMed

    Morimoto, Yoshihiro; Egawa, Chiyomi; Ishida, Tomo; Sato, Yasufumi; Kusama, Hiroki; Hashimoto, Tadayoshi; Matsushita, Katsunori; Kimura, Kei; Katsura, Yoshiteru; Nitta, Kanae; Kagawa, Yoshinori; Okishiro, Masatsugu; Takeno, Atsushi; Nakahira, Shin; Sakisaka, Hideki; Taniguchi, Hirokazu; Takeda, Yutaka; Kato, Takeshi; Tamura, Shigeyuki; Takatsuka, Yuichi

    2014-11-01

    Malignant bowel obstruction often causes oral intake difficulties and decreases quality of life. In Japan, gastroduodenal stenting for malignant gastric outlet obstruction has been covered by health insurance since 2010, while colon stenting has been covered since 2012. Both approaches are useful treatments for malignant bowel obstruction. Here we report the case of a woman with gastric outlet obstruction and rectal obstruction due to breast cancer metastases who was able to eat solid food after duodenal and colon stenting. When choosing whether to perform endoscopic stenting or surgical intervention such as gastrojejunostomy, ileostomy, and colostomy for treating malignant bowel obstruction, it is important to assess the patient's general condition and prognosis as well as the obstruction position.

  9. Isothermal amplification detection of nucleic acids by a double-nicked beacon.

    PubMed

    Shi, Chao; Zhou, Meiling; Pan, Mei; Zhong, Guilin; Ma, Cuiping

    2016-03-01

    Isothermal and rapid amplification detection of nucleic acids is an important technology in environmental monitoring, foodborne pathogen detection, and point-of-care clinical diagnostics. Here we have developed a novel method of isothermal signal amplification for single-stranded DNA (ssDNA) detection. The ssDNA target could be used as an initiator, coupled with a double-nicked molecular beacon, to originate amplification cycles, achieving cascade signal amplification. In addition, the method showed good specificity and strong anti-jamming capability. Overall, it is a one-pot and isothermal strand displacement amplification method without the requirement of a stepwise procedure, which greatly simplifies the experimental procedure and decreases the probability of contamination of samples. With its advantages, the method would be very useful to detect nucleic acids in point-of-care or field use. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Energy optimization for upstream data transfer in 802.15.4 beacon-enabled star formulation

    NASA Astrophysics Data System (ADS)

    Liu, Hua; Krishnamachari, Bhaskar

    2008-08-01

    Energy saving is one of the major concerns for low rate personal area networks. This paper models energy consumption for beacon-enabled time-slotted media accessing control cooperated with sleeping scheduling in a star network formulation for IEEE 802.15.4 standard. We investigate two different upstream (data transfer from devices to a network coordinator) strategies: a) tracking strategy: the devices wake up and check status (track the beacon) in each time slot; b) non-tracking strategy: nodes only wake-up upon data arriving and stay awake till data transmitted to the coordinator. We consider the tradeoff between energy cost and average data transmission delay for both strategies. Both scenarios are formulated as optimization problems and the optimal solutions are discussed. Our results show that different data arrival rate and system parameters (such as contention access period interval, upstream speed etc.) result in different strategies in terms of energy optimization with maximum delay constraints. Hence, according to different applications and system settings, different strategies might be chosen by each node to achieve energy optimization for both self-interested view and system view. We give the relation among the tunable parameters by formulas and plots to illustrate which strategy is better under corresponding parameters. There are two main points emphasized in our results with delay constraints: on one hand, when the system setting is fixed by coordinator, nodes in the network can intelligently change their strategies according to corresponding application data arrival rate; on the other hand, when the nodes' applications are known by the coordinator, the coordinator can tune the system parameters to achieve optimal system energy consumption.

  11. Multiplex detection of microRNAs by combining molecular beacon probes with T7 exonuclease-assisted cyclic amplification reaction.

    PubMed

    Liu, Yacui; Zhang, Jiangyan; Tian, Jingxiao; Fan, Xiaofei; Geng, Hao; Cheng, Yongqiang

    2017-01-01

    A simple, highly sensitive, and specific assay was developed for the homogeneous and multiplex detection of microRNAs (miRNAs) by combining molecular beacon (MB) probes and T7 exonuclease-assisted cyclic amplification. An MB probe with five base pairs in the stem region without special modification can effectively prevent the digestion by T7 exonuclease. Only in the presence of target miRNA is the MB probe hybridized with the target miRNA, and then digested by T7 exonuclease in the 5' to 3' direction. At the same time, the target miRNA is released and subsequently initiates the nuclease-assisted cyclic digestion process, generating enhanced fluorescence signal significantly. The results show that the combination of T7 exonuclease-assisted cyclic amplification reaction and MB probe possesses higher sensitivity for miRNA detection. Moreover, multiplex detection of miRNAs was successfully achieved by designing two MB probes labeled with FAM and Cy3, respectively. As a result, the method opens a new pathway for the sensitive and multiplex detection of miRNAs as well as clinical diagnosis. Graphical Abstract A simple, highly sensitive, and specific assay was developed for the detection of microRNAs by combining molecular beacon probes with T7 exonuclease-assisted cyclic amplification reaction.

  12. Design of a Combined Beacon Receiver and Digital Radiometer for 40 GHz Propagation Measurements at the Madrid Deep Space Communications Complex

    NASA Technical Reports Server (NTRS)

    Zemba, Michael; Nessel, James; Morabito, David

    2017-01-01

    NASA Glenn Research Center (GRC) and the Jet Propulsion Laboratory (JPL) have jointly developed an atmospheric propagation terminal to measure and characterize propagation phenomena at 40 GHz at the Madrid Deep Space Communications Complex (MDSCC) in Robledo de Chavela, Spain. The hybrid Q-band system utilizes a novel design which combines a 40 GHz beacon receiver and digital radiometer into the same RF front-end and observes the 39.402 GHz beacon of the European Space Agencys Alphasat Aldo Paraboni TDP5 experiment. Atmospheric measurements include gaseous absorption, rain fade, and scintillation. The radiometric measurement is calibrated by means of an included noise diode as well as tipping calibration. The goals of these measurements are to assist MDSCC mission operations as the facility increasingly supports Ka-band missions, as well as to contribute to the development and improvement of International Telecommunications Union (ITU) models for prediction of communications systems performance within the Q-band through the Aldo Paraboni Experiment. Herein, we provide an overview of the system design, characterization, and plan of operations which commenced at the MDSCC beginning in March 2017.

  13. 16S rRNA beacons for bacterial monitoring during human space missions.

    PubMed

    Larios-Sanz, Maia; Kourentzi, Katerina D; Warmflash, David; Jones, Jeffrey; Pierson, Duane L; Willson, Richard C; Fox, George E

    2007-04-01

    Microorganisms are unavoidable in space environments and their presence has, at times, been a source of problems. Concerns about disease during human space missions are particularly important considering the significant changes the immune system incurs during spaceflight and the history of microbial contamination aboard the Mir space station. Additionally, these contaminants may have adverse effects on instrumentation and life-support systems. A sensitive, highly specific system to detect, characterize, and monitor these microbial populations is essential. Herein we describe a monitoring approach that uses 16S rRNA targeted molecular beacons to successfully detect several specific bacterial groupings. This methodology will greatly simplify in-flight monitoring by minimizing sample handling and processing. We also address and provide solutions to target accessibility problems encountered in hybridizations that target 16S rRNA.

  14. Considerations for Community-Based mHealth Initiatives: Insights From Three Beacon Communities

    PubMed Central

    2013-01-01

    Mobile health (mHealth) is gaining widespread attention for its potential to engage patients in their health and health care in their daily lives. Emerging evidence suggests that mHealth interventions can be used effectively to support behavior change, but numerous challenges remain when implementing these programs at the community level. This paper provides an overview of considerations when implementing community-based mHealth initiatives, based on the experiences of three Beacon Communities across the United States that have launched text messaging (short message service, SMS) pilot programs aimed at diabetes risk reduction and disease management. The paper addresses lessons learned and suggests strategies to overcome challenges related to developing text message content, conducting marketing and outreach, enrolling participants, engaging providers, evaluating program effectiveness, and sustaining and scaling the programs. PMID:24128406

  15. Ground-water appraisal of the Fishkill-Beacon area, Dutchess County, New York

    USGS Publications Warehouse

    Snavely, Deborah S.

    1980-01-01

    The most productive aquifers in the Fishkill-Beacon area, Dutchess County, N.Y., are the sand and gravel beds in the northeast corner of the area and along the valleys of Fishkill and Clove Creeks. The average yield of these aquifers to wells is 190 gal/min (gallons per minute). The most productive bedrock aquifer is limestone, which yields an average of about 150 gal/min. Shale and granite each yield an average of less than 35 gal/min. About 4 billion gallons of available ground water is estimated to be in storage in the sand and gravel aquifers in the area. The area withdraws an average of 3.3 Mgal/d (million gallons per day) of water in June, July, and August and 2 Mgal/d during the remainder of the year. (USGS)

  16. Palliation double stenting for malignant biliary and duodenal obstruction

    PubMed Central

    ZHAO, LIANG; XU, HAITAO; ZHANG, YUBAO

    2016-01-01

    The surgical management of patients with malignant biliary and duodenal obstruction is complex. Tumor excision is no longer possible in the majority of patients with malignant obstructive jaundice and duodenal obstruction. The aim of the present study was to evaluate the effectiveness of intraluminal dual stent placement in malignant biliary and duodenal obstruction. In total, 20 patients with malignant obstructive jaundice and duodenal obstruction, including 6 with pancreatic carcinoma, 11 with cholangiocarcinoma, 1 with duodenal carcinoma and 2 with abdominal lymph node metastasis, were treated with intraluminal stent placement. Bile duct obstruction with late occurrence of duodenal obstruction was observed in 16 cases, and duodenal obstruction followed by a late occurrence of bile duct obstruction was observed in 3 cases, while, in 1 case, bile duct obstruction and duodenal obstruction occurred simultaneously. After X-ray fluoroscopy revealed obstruction in the bile duct and duodenum, stents were placed into the respective lumens. Percutaneous transhepatic placement was employed for the biliary stent, while the duodenal stent was placed perioraly. The clinical outcomes, including complications associated with the procedures and patency of the stents, were evaluated. The biliary and duodenal stents were successfully implanted in 18 patients and the technical success rate was 90% (18/20). A total of 39 stents were implanted in 20 patients. In 2 cases, duodenal stent placement failed following biliary stent placement. Duodenal obstruction remitted in 15 patients, and 1 patient succumbed to aspiration pneumonia 5 days after the procedure. No severe complications were observed in any other patient. The survival time of the 18 patients was 5–21 months (median, 9.6 months), and 6 of those patients survived for >12 months. The present study suggests that X-ray fluoroscopy-guided intraluminal stent implantation is an effective procedure for the treatment of malignant

  17. Is ursodeoxycholic acid detrimental in obstructive cholestasis? A propos of a case of malignant biliary obstruction.

    PubMed

    Bessone, Fernando; Roma, Marcelo Gabriel

    2016-01-01

    Ursodeoxycholic acid (UDCA) is the first choice medication for most cholestatic hepatopathies, due to its capability to counteract inflammation and bile-acid-induced liver damage, two common features in cholestasis. However, UDCA is usually contraindicated in obstructive cholestasis, due to the alleged risk of biliary integrity disruption due to its choleretic effect. We report on an 83-year-old man with an unsuspected malignant biliary obstruction who received moderate doses of UDCA (8-12 mg/kg/day) for 5 weeks, because the preliminary evidence suggested he had chemotherapy-induced cholestasis. Liver integrity was extensively protected by UDCA, as indicated by a marked decrease in serum liver enzymes, despite a steady increase in the levels of bilirubin and serum bile acids due to the obstructive process. In conclusion, this report shows, for the first time in humans, that moderate UDCA doses can reduce liver injury associated with complete biliary obstruction. This may contribute to a better understanding of the risk-benefit ratio of the use of UDCA in obstructive cholangiopathies.

  18. Obstructive uropathy

    MedlinePlus

    ... the kidney and causes it to become swollen ( hydronephrosis ). Obstructive uropathy can affect one or both kidneys. ... occurs during pregnancy. This condition is called idiopathic hydronephrosis of pregnancy.

  19. Trichophytobezoar duodenal obstruction in New World camelids.

    PubMed

    Sullivan, Eileen K; Callan, Robert J; Holt, Timothy N; Van Metre, David C

    2005-01-01

    To describe clinical findings, surgical treatment, and outcome associated with trichophytobezoar duodenal obstruction in New World camelids. Retrospective study. Alpacas (7) and 1 llama. Historical and clinical data were obtained from the medical records of New World camelids with a diagnosis of trichophytobezoar duodenal obstruction confirmed by surgical exploration or necropsy. Seven camelids were <1 year old. Abnormal clinical findings included anorexia, reduced fecal output, recumbency, colic, abdominal distension, regurgitation, decreased serum chloride concentration, increased serum bicarbonate concentration, and/or elevated first gastric compartment chloride concentration. Survey abdominal radiographs obtained (4 animals) revealed gastric distension (4) and/or visualization of the obstruction (2). Diagnosis was confirmed at necropsy (1) or surgery (7). Right paracostal celiotomy was performed on all animals and duodenotomy (3) or retropulsion of the trichophytobezoar combined with third compartment gastrotomy (4) was used to remove the obstruction. Six animals survived to discharge and 5 were healthy at follow-up, 8-20 months later. The remaining discharged alpaca was healthy at 12 months but subsequently died of unrelated causes. Diagnosis of trichophytobezoar duodenal obstruction should be considered in juvenile New World camelids with abdominal distension and hypochloremic metabolic alkalosis. Right paracostal celiotomy can be used for access to the descending duodenum and third gastric compartment for surgical relief of obstruction. Duodenal obstruction from bezoars should be considered in New World camelids <1year of age with abdominal distension and hypochloremic metabolic alkalosis. Surgical relief of the obstruction by right paracostal celiotomy has a good prognosis.

  20. 49 CFR 236.382 - Switch obstruction test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch obstruction test. 236.382 Section 236.382... and Tests § 236.382 Switch obstruction test. Switch obstruction test of lock rod of each power-operated switch and lock rod of each hand-operated switch equipped with switch-and-lock-movement shall be...

  1. 49 CFR 236.382 - Switch obstruction test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch obstruction test. 236.382 Section 236.382... and Tests § 236.382 Switch obstruction test. Switch obstruction test of lock rod of each power-operated switch and lock rod of each hand-operated switch equipped with switch-and-lock-movement shall be...

  2. 49 CFR 236.382 - Switch obstruction test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch obstruction test. 236.382 Section 236.382... and Tests § 236.382 Switch obstruction test. Switch obstruction test of lock rod of each power-operated switch and lock rod of each hand-operated switch equipped with switch-and-lock-movement shall be...

  3. 49 CFR 236.382 - Switch obstruction test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch obstruction test. 236.382 Section 236.382... and Tests § 236.382 Switch obstruction test. Switch obstruction test of lock rod of each power-operated switch and lock rod of each hand-operated switch equipped with switch-and-lock-movement shall be...

  4. 49 CFR 236.382 - Switch obstruction test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch obstruction test. 236.382 Section 236.382... and Tests § 236.382 Switch obstruction test. Switch obstruction test of lock rod of each power-operated switch and lock rod of each hand-operated switch equipped with switch-and-lock-movement shall be...

  5. Design and Analysis of A Beacon-Less Routing Protocol for Large Volume Content Dissemination in Vehicular Ad Hoc Networks.

    PubMed

    Hu, Miao; Zhong, Zhangdui; Ni, Minming; Baiocchi, Andrea

    2016-11-01

    Large volume content dissemination is pursued by the growing number of high quality applications for Vehicular Ad hoc NETworks(VANETs), e.g., the live road surveillance service and the video-based overtaking assistant service. For the highly dynamical vehicular network topology, beacon-less routing protocols have been proven to be efficient in achieving a balance between the system performance and the control overhead. However, to the authors' best knowledge, the routing design for large volume content has not been well considered in the previous work, which will introduce new challenges, e.g., the enhanced connectivity requirement for a radio link. In this paper, a link Lifetime-aware Beacon-less Routing Protocol (LBRP) is designed for large volume content delivery in VANETs. Each vehicle makes the forwarding decision based on the message header information and its current state, including the speed and position information. A semi-Markov process analytical model is proposed to evaluate the expected delay in constructing one routing path for LBRP. Simulations show that the proposed LBRP scheme outperforms the traditional dissemination protocols in providing a low end-to-end delay. The analytical model is shown to exhibit a good match on the delay estimation with Monte Carlo simulations, as well.

  6. Design and Analysis of A Beacon-Less Routing Protocol for Large Volume Content Dissemination in Vehicular Ad Hoc Networks

    PubMed Central

    Hu, Miao; Zhong, Zhangdui; Ni, Minming; Baiocchi, Andrea

    2016-01-01

    Large volume content dissemination is pursued by the growing number of high quality applications for Vehicular Ad hoc NETworks(VANETs), e.g., the live road surveillance service and the video-based overtaking assistant service. For the highly dynamical vehicular network topology, beacon-less routing protocols have been proven to be efficient in achieving a balance between the system performance and the control overhead. However, to the authors’ best knowledge, the routing design for large volume content has not been well considered in the previous work, which will introduce new challenges, e.g., the enhanced connectivity requirement for a radio link. In this paper, a link Lifetime-aware Beacon-less Routing Protocol (LBRP) is designed for large volume content delivery in VANETs. Each vehicle makes the forwarding decision based on the message header information and its current state, including the speed and position information. A semi-Markov process analytical model is proposed to evaluate the expected delay in constructing one routing path for LBRP. Simulations show that the proposed LBRP scheme outperforms the traditional dissemination protocols in providing a low end-to-end delay. The analytical model is shown to exhibit a good match on the delay estimation with Monte Carlo simulations, as well. PMID:27809285

  7. Hypertrophic obstructive cardiomyopathy: the Mayo Clinic experience.

    PubMed

    Kotkar, Kunal D; Said, Sameh M; Dearani, Joseph A; Schaff, Hartzell V

    2017-07-01

    Hypertrophic cardiomyopathy (HCM) is a primary myocardial disease characterized by left ventricular hypertrophy in the absence of other etiologies. Clinical presentation may vary from asymptomatic to sudden cardiac death. Medical treatment is the first-line therapy for symptomatic patients. Extended left ventricular septal myectomy is the procedure of choice if medical treatment is unsuccessful or intolerable. More than 3,000 patients have had septal myectomy for HCM at the Mayo Clinic (MN, USA) from 1993 to 2016. Risk of hospital death after isolated septal myectomy for obstructive HCM is <1% and is similar to the risk of operation for elective mitral valve repair. Complications, such as complete heart block requiring permanent pacemaker, are uncommon (2%), although partial or complete left bundle branch block is a frequent finding on the postoperative ECG. Relief of left ventricular outflow tract (LVOT) obstruction with septal myectomy dramatically improves symptoms and exercise capacity in symptomatic patients with obstructive HCM. More than 90% of severely symptomatic patients have improvement by at least two functional classes, and reduction of outflow gradients by myectomy decreases or eliminates symptoms of dyspnea, angina and/or syncope. Basal obstruction with systolic anterior motion (SAM) is treated by transaortic myectomy. The transapical approach was applied in 115 patients with obstructive midventricular and apical variants of HCM between 1993 and 2012. All patients with midventricular obstruction had gradient relief and none developed an apical aneurysm or ventricular septal defect. Recurrent obstruction after satisfactory myectomy was rare. Septal myectomy effectively and definitively relieves LVOT obstruction and cardiac symptoms in patients with obstructive HCM. In experienced centers, early mortality for isolated septal myectomy is less than 1%, and overall results are excellent and continue to improve in the current era.

  8. 33 CFR 67.20-5 - Obstruction lights.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Obstruction lights. 67.20-5... Obstruction lights. The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this part. The lights shall be of sufficient candlepower as to be visible at a distance of at least five nautical...

  9. 33 CFR 67.20-5 - Obstruction lights.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Obstruction lights. 67.20-5... Obstruction lights. The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this part. The lights shall be of sufficient candlepower as to be visible at a distance of at least five nautical...

  10. 33 CFR 67.20-5 - Obstruction lights.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Obstruction lights. 67.20-5... Obstruction lights. The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this part. The lights shall be of sufficient candlepower as to be visible at a distance of at least five nautical...

  11. 33 CFR 67.20-5 - Obstruction lights.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Obstruction lights. 67.20-5... Obstruction lights. The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this part. The lights shall be of sufficient candlepower as to be visible at a distance of at least five nautical...

  12. 33 CFR 67.20-5 - Obstruction lights.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Obstruction lights. 67.20-5... Obstruction lights. The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this part. The lights shall be of sufficient candlepower as to be visible at a distance of at least five nautical...

  13. Tuberculosis associated chronic obstructive pulmonary disease.

    PubMed

    Sarkar, Malay; Srinivasa; Madabhavi, Irappa; Kumar, Kushal

    2017-05-01

    Reviewed the epidemiology, clinical characteristics, mechanisms, and treatment of tuberculosis associated chronic obstructive pulmonary disease. We searched PubMed, EMBASE, and the CINAHL from inception to June 2016. We used the following search terms: Tuberculosis, COPD, Tuberculosis associated COPD, and so forth. All types of study were chosen. Chronic obstructive pulmonary disease (COPD) and tuberculosis are significant public health problems, particularly in developing countries. Although, smoking is the conventional risk factor for COPD, nonsmoking related risk factors such as biomass fuel exposure, childhood lower-respiratory tract infections, chronic asthma, outdoor air pollution, and prior history of pulmonary tuberculosis have become important risk factors of COPD, particularly in developing countries. Past history of tuberculosis as a risk factor of chronic airflow obstruction has been reported in several studies. It may develop during the course of tuberculosis or after completion of tuberculosis treatment. Developing countries with large burden of tuberculosis can contribute significantly to the burden of chronic airflow obstruction. Prompt diagnosis and treatment of tuberculosis should be emphasized to lessen the future burden of chronic airflow obstruction. © 2017 John Wiley & Sons Ltd.

  14. Stenting in Malignant Biliary Obstruction.

    PubMed

    Almadi, Majid A; Barkun, Jeffrey S; Barkun, Alan N

    2015-10-01

    Decompression of the biliary system in patients with malignant biliary obstruction has been widely accepted and implemented as part of the care. Despite a wealth of literature, there remains a significant amount of uncertainty as to which approach would be most appropriate in different clinical settings. This review covers stenting of the biliary system in cases of resectable or palliative malignant biliary obstruction, potential candidates for biliary drainage, technical aspects of the procedure, as well as management of biliary stent dysfunction. Furthermore, periprocedural considerations including proper mapping of the location of obstruction and the use of antibiotics are addressed. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. 33 CFR 67.30-5 - Obstruction lights.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Obstruction lights. 67.30-5... Obstruction lights. (a) The obstruction lights shall be white or red lights as prescribed in Subpart 67.05 of... nautical mile 90 percent of the nights of the year. The lights shall be displayed at such height, above...

  16. 33 CFR 67.25-5 - Obstruction lights.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Obstruction lights. 67.25-5... Obstruction lights. (a) The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this... miles 90 percent of the nights of the year. The lights shall be displayed not less than 20 feet above...

  17. 33 CFR 67.30-5 - Obstruction lights.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Obstruction lights. 67.30-5... Obstruction lights. (a) The obstruction lights shall be white or red lights as prescribed in Subpart 67.05 of... nautical mile 90 percent of the nights of the year. The lights shall be displayed at such height, above...

  18. 33 CFR 67.30-5 - Obstruction lights.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Obstruction lights. 67.30-5... Obstruction lights. (a) The obstruction lights shall be white or red lights as prescribed in Subpart 67.05 of... nautical mile 90 percent of the nights of the year. The lights shall be displayed at such height, above...

  19. 33 CFR 67.25-5 - Obstruction lights.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Obstruction lights. 67.25-5... Obstruction lights. (a) The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this... miles 90 percent of the nights of the year. The lights shall be displayed not less than 20 feet above...

  20. 33 CFR 67.30-5 - Obstruction lights.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Obstruction lights. 67.30-5... Obstruction lights. (a) The obstruction lights shall be white or red lights as prescribed in Subpart 67.05 of... nautical mile 90 percent of the nights of the year. The lights shall be displayed at such height, above...

  1. 33 CFR 67.30-5 - Obstruction lights.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Obstruction lights. 67.30-5... Obstruction lights. (a) The obstruction lights shall be white or red lights as prescribed in Subpart 67.05 of... nautical mile 90 percent of the nights of the year. The lights shall be displayed at such height, above...

  2. 33 CFR 67.25-5 - Obstruction lights.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Obstruction lights. 67.25-5... Obstruction lights. (a) The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this... miles 90 percent of the nights of the year. The lights shall be displayed not less than 20 feet above...

  3. Bowel obstruction complicated by ischemia: analysis of CT findings.

    PubMed

    Cox, Veronica L; Tahvildari, Ali M; Johnson, Benjamin; Wei, Wei; Jeffrey, R Brooke

    2018-06-01

    To analyze CT signs of bowel ischemia in patients with surgical bowel obstruction, and thereby improve CT diagnosis in this common clinical scenario. Surgical and histopathological findings were used as the reference standard. We retrospectively analyzed CT findings in patients brought to surgery for bowel obstruction over 13 years. Etiology of obstruction (adhesion, hernia, etc.) was recorded. Specific CT features of acute mesenteric ischemia (AMI) were analyzed, including bowel wall thickening, mucosal hypoenhancement, and others. 173 cases were eligible for analysis. 21% of cases were positive for bowel ischemia. Volvulus, internal hernia, and closed-loop obstructions showed ischemia rates of 60%, 43%, and 43%; ischemia rate in obstruction from simple adhesion was 21%. Patients with bowel obstruction related to malignancy were never ischemic. Sensitivities and specificities for CT features predicting ischemia were calculated, with wall thickening, hypoenhancement, and pneumatosis showing high specificity for ischemia (86%-100%). Wall thickening, hypoenhancement, and pneumatosis are highly specific CT signs of ischemia in the setting of obstruction. None of the evaluated CT signs were found to be highly sensitive. Overall frequency of ischemia in surgical bowel obstruction is 21%, and 2-3 times that for complex obstructions (volvulus, closed loop, etc.). Obstructions related to malignancy virtually never become ischemic.

  4. Localization of glossopharyngeal obstruction using nasopharyngeal tube versus Friedman tongue position classification in obstructive sleep apnea hypopnea syndrome.

    PubMed

    Li, Shuhua; Hei, Renyi; Wu, Dahai; Shi, Hongjin

    2014-08-01

    Assessing the severity of glossopharyngeal obstruction is important for the diagnosis and therapy of obstructive sleep apnea hypopnea syndrome (OSAHS). The polysomnography (PSG) with nasopharyngeal tube insertion (NPT-PSG) has shown good results in assessing glossopharyngeal obstruction. The objective of this study was to compare NPT-PSG with Friedman tongue position (FTP) classification which was also used to evaluate the glossopharyngeal obstruction. One hundred and five patients with OSAHS diagnosed by PSG were included in the study. All the patients were successfully examined by NPT-PSG. Based on the grade of FTP classification, 105 patients were divided into four groups. The differences of the general clinical data, PSG and NPT-PSG results were analyzed among the four groups. And the coincidence of diagnosing glossopharyngeal obstruction of two methods was calculated. There was no significant difference among the four groups in general clinical data and PSG results. However, NPT-PSG results were significantly different among the four groups. Following with the increasing FTP, apnea hypopnea index increased and lowest saturation of blood oxygen decreased. There were 38 patients with and other 38 patients without glossopharyngeal obstruction diagnosed by both methods. The coincidence of two methods was 72.4 %. NPT-PSG is an easy and effective method in assessing the severity of glossopharyngeal obstruction. The coincidence between the NPT-PSG and FTP classification is good. But in some special OSAHS patients such as glossoptosis, unsuccessful uvulopalatopharyngoplasty or suspicious pachyglossia, NPT-PSG is better than FTP classification.

  5. Intestinal obstruction

    MedlinePlus

    ... of the bowel may be due to: A mechanical cause, which means something is in the way ... lung disease Use of certain medicines, especially narcotics Mechanical causes of intestinal obstruction may include: Adhesions or ...

  6. Peptide Beacons: A New Design for Polypeptide-Based Optical Biosensors

    PubMed Central

    Oh, Kenneth J.; Cash, Kevin J.; Hugenberg, Verena; Plaxco, Kevin W.

    2008-01-01

    Phage display and other in vitro selection techniques produce short polypeptides that tightly and specifically bind to any of a wide range of macromolecular targets. Here we demonstrate a potentially general means of converting such polypeptides into optical biosensors. The sensing architecture we have developed, termed peptide beacons, is based on the observation that, whereas short peptides are almost invariably unfolded and highly dynamic, they become rigid when complexed to their target. Using this effect to segregate a long-lived fluorophore from an electron transfer-based contact quencher, both covalently attached to the peptide, we have produced a robust optical sensor for anti-HIV antibodies. The binding-induced segregation of the fluorophore-quencher pair produces a six-fold increase in sensor emission, thus allowing us to readily detect as low as ∼250 pM of the target antibody. Because the sensor is based on binding-induced folding and a visible-light fluorophore, it is sufficiently selective to work directly in complex, contaminant-ridden samples such as saliva and blood. PMID:17461545

  7. An Elegant Biosensor Molecular Beacon Probe: Challenges and Recent Solutions

    PubMed Central

    Kolpashchikov, Dmitry M.

    2012-01-01

    Molecular beacon (MB) probes are fluorophore- and quencher-labeled short synthetic DNAs folded in a stem-loop shape. Since the first report by Tyagi and Kramer, it has become a widely accepted tool for nucleic acid analysis and triggered a cascade of related developments in the field of molecular sensing. The unprecedented success of MB probes stems from their ability to detect specific DNA or RNA sequences immediately after hybridization with no need to wash out the unbound probe (instantaneous format). Importantly, the hairpin structure of the probe is responsible for both the low fluorescent background and improved selectivity. Furthermore, the signal is generated in a reversible manner; thus, if the analyte is removed, the signal is reduced to the background. This paper highlights the advantages of MB probes and discusses the approaches that address the challenges in MB probe design. Variations of MB-based assays tackle the problem of stem invasion, improve SNP genotyping and signal-to-noise ratio, as well as address the challenges of detecting folded RNA and DNA. PMID:24278758

  8. VLC-beacon detection with an under-sampled ambient light sensor

    NASA Astrophysics Data System (ADS)

    Green, Jacob; Pérez-Olivas, Huetzin; Martínez-Díaz, Saúl; García-Márquez, Jorge; Domínguez-González, Carlos; Santiago-Montero, Raúl; Guan, Hongyu; Rozenblat, Marc; Topsu, Suat

    2017-08-01

    LEDs will replace in a near future the current worldwide lighting mainly due to their low production-cost and energy-saving assets. Visible light communications (VLC) will turn gradually the existing lighting network into a communication network. Nowadays VLC transceivers can be found in some commercial centres in Europe; some of them broadcast continuously an identification tag that contains its coordinate position. In such a case, the transceiver acts as a geolocation beacon. Nevertheless, mobile transceivers represent a challenge in the VLC communication chain, as smartphones have not integrated yet a VLC customized detection stage. In order to make current smartphones capable to detect VLC broadcasted signals, their Ambient Light Sensor (ALS) is adapted as a VLC detector. For this to be achieved, lighting transceivers need to adapt their modulation scheme. For instance, frequencies representing start bit, 1, and 0 logic values can be set to avoid flicker from illumination and to permit detecting the under-sampled signal. Decoding the signal requires a multiple steps real-time signal processing as shown here.

  9. NanoCluster Beacons as reporter probes in rolling circle enhanced enzyme activity detection

    NASA Astrophysics Data System (ADS)

    Juul, Sissel; Obliosca, Judy M.; Liu, Cong; Liu, Yen-Liang; Chen, Yu-An; Imphean, Darren M.; Knudsen, Birgitta R.; Ho, Yi-Ping; Leong, Kam W.; Yeh, Hsin-Chih

    2015-04-01

    As a newly developed assay for the detection of endogenous enzyme activity at the single-catalytic-event level, Rolling Circle Enhanced Enzyme Activity Detection (REEAD) has been used to measure enzyme activity in both single human cells and malaria-causing parasites, Plasmodium sp. Current REEAD assays rely on organic dye-tagged linear DNA probes to report the rolling circle amplification products (RCPs), the cost of which may hinder the widespread use of REEAD. Here we show that a new class of activatable probes, NanoCluster Beacons (NCBs), can simplify the REEAD assays. Easily prepared without any need for purification and capable of large fluorescence enhancement upon hybridization, NCBs are cost-effective and sensitive. Compared to conventional fluorescent probes, NCBs are also more photostable. As demonstrated in reporting the human topoisomerases I (hTopI) cleavage-ligation reaction, the proposed NCBs suggest a read-out format attractive for future REEAD-based diagnostics.As a newly developed assay for the detection of endogenous enzyme activity at the single-catalytic-event level, Rolling Circle Enhanced Enzyme Activity Detection (REEAD) has been used to measure enzyme activity in both single human cells and malaria-causing parasites, Plasmodium sp. Current REEAD assays rely on organic dye-tagged linear DNA probes to report the rolling circle amplification products (RCPs), the cost of which may hinder the widespread use of REEAD. Here we show that a new class of activatable probes, NanoCluster Beacons (NCBs), can simplify the REEAD assays. Easily prepared without any need for purification and capable of large fluorescence enhancement upon hybridization, NCBs are cost-effective and sensitive. Compared to conventional fluorescent probes, NCBs are also more photostable. As demonstrated in reporting the human topoisomerases I (hTopI) cleavage-ligation reaction, the proposed NCBs suggest a read-out format attractive for future REEAD-based diagnostics. Electronic

  10. Congenital Urinary Tract Obstruction: The Long View

    PubMed Central

    Chevalier, Robert L.

    2015-01-01

    Maldevelopment of the collecting system resulting in urinary tract obstruction (UTO) is the leading identifiable cause of CKD in children. Specific etiologies are unknown; most cases are suspected by discovering hydronephrosis on prenatal ultrasonography. Congenital UTO can reduce nephron number and cause bladder dysfunction, which contribute to ongoing injury. Severe UTO can impair kidney growth in utero, and animal models of unilateral ureteral obstruction show that ischemia and oxidative stress cause proximal tubular cell death, with later development of interstitial fibrosis. Congenital obstructive nephropathy therefore results from combined developmental and obstructive renal injury. Due to inadequacy of available biomarkers, criteria for surgical correction of upper tract obstruction are poorly established. Lower tract obstruction requires fetal or immediate postnatal intervention, and the rate of progression of CKD is highly variable. New biomarkers based on proteomics and determination of glomerular number by MRI should improve future care. Angiotensin inhibitors have not been effective in slowing progression, although avoidance of nephrotoxins and timely treatment of hypertension are important. Because congenital UTO begins in fetal life, smooth transfer of care from perinatologist to pediatric and adult urology and nephrology teams should optimize quality of life and ultimate outcomes for these patients. PMID:26088076

  11. Bladder outlet obstruction in women: definition and characteristics.

    PubMed

    Groutz, A; Blaivas, J G; Chaikin, D C

    2000-01-01

    The prevalence of bladder outlet obstruction in women is unknown and most probably has been underestimated. Moreover, there are no standard definitions for the diagnosis of bladder outlet obstruction in women. Our study was conducted to define as well as to examine the clinical and urodynamic characteristics of bladder outlet obstruction among women referred for evaluation of voiding symptoms. Bladder outlet obstruction was defined as a persistent, low, maximum "free" flow rate of <12 mL/s in repeated non-invasive uroflow studies, combined with high detrusor pressure at a maximum flow (p(det.Q)(max) >20 cm H(2)O) during detrusor pressure-uroflow studies. A urodynamic database of 587 consecutive women identified 38 (6.5%) women with bladder outlet obstruction. The mean age of the patients was 63.9 +/- 17.5 years. The mean maximum "free" flow, voided volume, and residual urinary volume were 9.4 +/-3.9 mL/s, 144. 9 +/- 72.7 mL, and 86.1 +/- 98.8 mL, respectively. The mean p(det. Q)(max) was 37.2 +/- 19.2 cm H(2)O. Previous anti-incontinence surgery and severe genital prolapse were the most common etiologies, accounting for half of the cases. Other, less common, etiologies included urethral stricture (13%), primary bladder neck obstruction (8%), learned voiding dysfunction (5%), and detrusor external sphincter dyssynergia (5%). Symptomatology was defined as mixed obstructive and irritative in 63% of the patients, isolated irritative in 29%, and isolated obstructive in other 8%. In conclusion, bladder outlet obstruction in women appears to be more common than was previously recognized, occurring in 6.5% of our patients. Micturition symptoms relevant to bladder outlet obstruction are non-specific, and a full urodynamic evaluation is essential in making the correct diagnosis and formulating a treatment plan.

  12. Drug-induced sleep endoscopy in the identification of obstruction sites in patients with obstructive sleep apnea: a systematic review.

    PubMed

    Viana, Alonço da Cunha; Thuler, Luiz Claudio Santos; Araújo-Melo, Maria Helena de

    2015-01-01

    Obstructive sleep apnea syndrome has multifactorial causes. Although indications for surgery are evaluated by well-known diagnostic tests in the awake state, these do not always correlate with satisfactory surgical results. To undertake a systematic review on endoscopy during sleep, as one element of the diagnosis routine, aiming to identify upper airway obstruction sites in adult patients with OSAS. By means of electronic databases, a systematic review was performed of studies using drug-induced sleep endoscopy to identify obstruction sites in patients with OSAS. Ten articles were selected that demonstrated the importance of identifying multilevel obstruction, especially in relation to retrolingual and laryngeal collapse in OSAS. DISE is an additional method to reveal obstruction sites that have not been detected in awake patients. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  13. Avoiding Obstructions in Aiming a High-Gain Antenna

    NASA Technical Reports Server (NTRS)

    Edmonds, Karina

    2006-01-01

    The High Gain Antenna Pointing and Obstruction Avoidance software performs computations for pointing a Mars Rover high-gain antenna for communication with Earth while (1) avoiding line-of-sight obstructions (the Martian terrain and other parts of the Rover) that would block communication and (2) taking account of limits in ranges of motion of antenna gimbals and of kinematic singularities in gimbal mechanisms. The software uses simplified geometric models of obstructions and of the trajectory of the Earth in the Martian sky(see figure). It treats all obstructions according to a generalized approach, computing and continually updating the time remaining before interception of each obstruction. In cases in which the gimbal-mechanism design allows two aiming solutions, the algorithm chooses the solution that provides the longest obstruction-free Earth-tracking time. If the communication session continues until an obstruction is encountered in the current pointing solution and the other solution is now unobstructed, then the algorithm automatically switches to the other position. This software also notifies communication- managing software to cease transmission during the switch to the unobstructed position, resuming it when the switch is complete.

  14. 36 CFR 4.13 - Obstructing traffic.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... interfere with the normal flow of traffic. ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Obstructing traffic. 4.13... VEHICLES AND TRAFFIC SAFETY § 4.13 Obstructing traffic. The following are prohibited: (a) Stopping or...

  15. 36 CFR 4.13 - Obstructing traffic.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... interfere with the normal flow of traffic. ... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Obstructing traffic. 4.13... VEHICLES AND TRAFFIC SAFETY § 4.13 Obstructing traffic. The following are prohibited: (a) Stopping or...

  16. 36 CFR 4.13 - Obstructing traffic.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... interfere with the normal flow of traffic. ... 36 Parks, Forests, and Public Property 1 2013-07-01 2013-07-01 false Obstructing traffic. 4.13... VEHICLES AND TRAFFIC SAFETY § 4.13 Obstructing traffic. The following are prohibited: (a) Stopping or...

  17. Effect of bilastine upon nasal obstruction.

    PubMed

    Dávila, I; Sastre, J; Mullol, J; Montoro, J; Jáuregui, I; Ferrer, M; del Cuvillo, A; Bartra, J; Valero, A

    2011-01-01

    H1 antihistamines constitute one of the main references for the treatment of allergic rhinitis. Classically, these drugs have been considered effective in controlling sneezing, rhinorrhea and itching, though they have not been regarded as particularly effective in application to nasal obstruction. The most recent studies, involving second-generation H1 antihistamines (desloratadine, fexofenadine, levocetirizine, rupatadine), have shown these drugs to offer effects upon nasal obstruction significantly superior to those of placebo. The present review examines the effect of bilastine, a new, potent and highly specific H1 antihistamine without sedative effects or cardiac toxicity, upon nasal obstruction. The analysis of the data from the different clinical trials indicates that in patients with allergic rhinitis, the effect of bilastine upon nasal obstruction is superior to that of placebo and similar to that of other second-generation H1 antihistamines, manifesting within 24 hours after the start of treatment.

  18. Simple fluorescence-based detection of protein kinase A activity using a molecular beacon probe.

    PubMed

    Ma, Changbei; Lv, Xiaoyuan; Wang, Kemin; Jin, Shunxin; Liu, Haisheng; Wu, Kefeng; Zeng, Weimin

    2017-11-02

    Protein kinase A was detected by quantifying the amount of ATP used after a protein kinase reaction. The ATP assay was performed using the T4 DNA ligase and a molecular beacon (MB). In the presence of ATP, DNA ligase catalyzed the ligation of short DNA. The ligation product then hybridized to MB, resulting in a fluorescence enhancement of the MB. This assay was capable of determining protein kinase A in the range of 12.5∼150 nM, with a detection limit of 1.25 nM. Furthermore, this assay could also be used to investigate the effect of genistein on protein kinase A. It was a universal, non-radioisotopic, and homogeneous method for assaying protein kinase A.

  19. 33 CFR 67.05-5 - Multiple obstruction lights.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Multiple obstruction lights. 67... for Lights § 67.05-5 Multiple obstruction lights. When more than one obstruction light is required by this part to mark a structure, all such lights shall be operated to flash in unison. ...

  20. 33 CFR 67.05-5 - Multiple obstruction lights.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Multiple obstruction lights. 67... for Lights § 67.05-5 Multiple obstruction lights. When more than one obstruction light is required by this part to mark a structure, all such lights shall be operated to flash in unison. ...

  1. 33 CFR 67.05-5 - Multiple obstruction lights.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Multiple obstruction lights. 67... for Lights § 67.05-5 Multiple obstruction lights. When more than one obstruction light is required by this part to mark a structure, all such lights shall be operated to flash in unison. ...

  2. 33 CFR 67.05-5 - Multiple obstruction lights.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Multiple obstruction lights. 67... for Lights § 67.05-5 Multiple obstruction lights. When more than one obstruction light is required by this part to mark a structure, all such lights shall be operated to flash in unison. ...

  3. 33 CFR 67.05-5 - Multiple obstruction lights.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Multiple obstruction lights. 67... for Lights § 67.05-5 Multiple obstruction lights. When more than one obstruction light is required by this part to mark a structure, all such lights shall be operated to flash in unison. ...

  4. Influence of obstructive jaundice on pharmacodynamics of rocuronium.

    PubMed

    Wang, Zhen-Meng; Zhang, Peng; Lin, Mi-Jia; Tan, Bo; Qiu, Hai-Bo; Yu, Wei-Feng

    2013-01-01

    Anesthetics are variable in patients with obstructive jaundice. The minimum alveolar concentration awake of desflurane is reduced in patients with obstructive jaundice, while it has no effect on pharmacodynamics and pharmacokinetics of propofol. In this study, we investigated the influence of obstructive jaundice on the pharmacodynamics and blood concentration of rocuronium. Included in this study were 26 control patients and 27 patients with obstructive jaundice. Neuromuscular block of rocuronium was monitored by acceleromyography. Onset time, spontaneous recovery of the height of twitch first (T1) to 25% of the final T1 value (Duration 25%, Dur 25%), recovery index (RI), and spontaneous recovery of train-of-four (TOF) ratios to 70% were measured. The plasma rocuronium concentrations were determined by high performance liquid chromatography using berberine as an internal standard. There was no significant difference in onset time between the two groups. The Dur 25%, the recovery index and the time of recovery of the TOF ratios to 70% were all prolonged in the obstructive jaundice group compared with the control group. The plasma concentration of rocuronium at 60, 90 and 120 min after bolus administration was significantly higher in the obstructive jaundice group. The neuromuscular blockade by rocuronium is prolonged in obstructive jaundice patients, and therefore precautions should be taken in case of postoperative residual neuromuscular block. The possible reason is impedance of rocuronium excretion due to biliary obstruction and increased plasma unbound rocuronium because of free bilirubin competing with it for albumin binding.

  5. Accuracy of abdominal auscultation for bowel obstruction.

    PubMed

    Breum, Birger Michael; Rud, Bo; Kirkegaard, Thomas; Nordentoft, Tyge

    2015-09-14

    To investigate the accuracy and inter-observer variation of bowel sound assessment in patients with clinically suspected bowel obstruction. Bowel sounds were recorded in patients with suspected bowel obstruction using a Littmann(®) Electronic Stethoscope. The recordings were processed to yield 25-s sound sequences in random order on PCs. Observers, recruited from doctors within the department, classified the sound sequences as either normal or pathological. The reference tests for bowel obstruction were intraoperative and endoscopic findings and clinical follow up. Sensitivity and specificity were calculated for each observer and compared between junior and senior doctors. Interobserver variation was measured using the Kappa statistic. Bowel sound sequences from 98 patients were assessed by 53 (33 junior and 20 senior) doctors. Laparotomy was performed in 47 patients, 35 of whom had bowel obstruction. Two patients underwent colorectal stenting due to large bowel obstruction. The median sensitivity and specificity was 0.42 (range: 0.19-0.64) and 0.78 (range: 0.35-0.98), respectively. There was no significant difference in accuracy between junior and senior doctors. The median frequency with which doctors classified bowel sounds as abnormal did not differ significantly between patients with and without bowel obstruction (26% vs 23%, P = 0.08). The 53 doctors made up 1378 unique pairs and the median Kappa value was 0.29 (range: -0.15-0.66). Accuracy and inter-observer agreement was generally low. Clinical decisions in patients with possible bowel obstruction should not be based on auscultatory assessment of bowel sounds.

  6. Accuracy of abdominal auscultation for bowel obstruction

    PubMed Central

    Breum, Birger Michael; Rud, Bo; Kirkegaard, Thomas; Nordentoft, Tyge

    2015-01-01

    AIM: To investigate the accuracy and inter-observer variation of bowel sound assessment in patients with clinically suspected bowel obstruction. METHODS: Bowel sounds were recorded in patients with suspected bowel obstruction using a Littmann® Electronic Stethoscope. The recordings were processed to yield 25-s sound sequences in random order on PCs. Observers, recruited from doctors within the department, classified the sound sequences as either normal or pathological. The reference tests for bowel obstruction were intraoperative and endoscopic findings and clinical follow up. Sensitivity and specificity were calculated for each observer and compared between junior and senior doctors. Interobserver variation was measured using the Kappa statistic. RESULTS: Bowel sound sequences from 98 patients were assessed by 53 (33 junior and 20 senior) doctors. Laparotomy was performed in 47 patients, 35 of whom had bowel obstruction. Two patients underwent colorectal stenting due to large bowel obstruction. The median sensitivity and specificity was 0.42 (range: 0.19-0.64) and 0.78 (range: 0.35-0.98), respectively. There was no significant difference in accuracy between junior and senior doctors. The median frequency with which doctors classified bowel sounds as abnormal did not differ significantly between patients with and without bowel obstruction (26% vs 23%, P = 0.08). The 53 doctors made up 1378 unique pairs and the median Kappa value was 0.29 (range: -0.15-0.66). CONCLUSION: Accuracy and inter-observer agreement was generally low. Clinical decisions in patients with possible bowel obstruction should not be based on auscultatory assessment of bowel sounds. PMID:26379407

  7. A catalytic and dual recycling amplification ATP sensor based on target-driven allosteric structure switching of aptamer beacons.

    PubMed

    Peng, Ying; Li, Daxiu; Yuan, Ruo; Xiang, Yun

    2018-05-15

    Abnormal concentrations of ATP are associated with many diseases and cancers, and quantitative detection of ATP is thus of great importance for disease diagnosis and prognosis. In the present work, we report a new dual recycling amplification sensor integrated with catalytic hairpin assembly (CHA) to achieve high sensitivity for fluorescent detection of ATP. The association of the target ATP with the aptamer beacons causes the allosteric structure switching of the aptamer beacons to expose the toehold regions, which hybridize with and unfold the fluorescently quenched hairpin signal probes (HP1) to recycle the target ATP and to trigger CHA between HP1 and the secondary hairpin probes (HP2) to form HP1/HP2 duplexes. Due to the recycling amplification, the presence of ATP leads to the formation of many HP1/HP2 duplexes, generating dramatically amplified fluorescent signals for sensitive detection of ATP. Under optimal experimental conditions, our sensor linearly responds to ATP in the range from 25 to 600nM with a calculated detection limit of 8.2nM. Furthermore, the sensor shows a high selectivity and can also be used to detect ATP in human serums to realize its application for real samples. With the distinct advantage of significant signal amplification without the involvement of any nanomaterial and enzyme, the developed sensor thus holds great potential for simple and sensitive detection of different small molecules and proteins. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Influence of Obstructive Jaundice on Pharmacodynamics of Rocuronium

    PubMed Central

    Lin, Mi-Jia; Tan, Bo; Qiu, Hai-Bo; Yu, Wei-Feng

    2013-01-01

    Background Anesthetics are variable in patients with obstructive jaundice. The minimum alveolar concentration awake of desflurane is reduced in patients with obstructive jaundice, while it has no effect on pharmacodynamics and pharmacokinetics of propofol. In this study, we investigated the influence of obstructive jaundice on the pharmacodynamics and blood concentration of rocuronium. Methods Included in this study were 26 control patients and 27 patients with obstructive jaundice. Neuromuscular block of rocuronium was monitored by acceleromyography. Onset time, spontaneous recovery of the height of twitch first (T1) to 25% of the final T1 value (Duration 25%, Dur 25%), recovery index (RI), and spontaneous recovery of train-of-four (TOF) ratios to 70% were measured. The plasma rocuronium concentrations were determined by high performance liquid chromatography using berberine as an internal standard. Results There was no significant difference in onset time between the two groups. The Dur 25%, the recovery index and the time of recovery of the TOF ratios to 70% were all prolonged in the obstructive jaundice group compared with the control group. The plasma concentration of rocuronium at 60, 90 and 120 min after bolus administration was significantly higher in the obstructive jaundice group. Conclusions The neuromuscular blockade by rocuronium is prolonged in obstructive jaundice patients, and therefore precautions should be taken in case of postoperative residual neuromuscular block. The possible reason is impedance of rocuronium excretion due to biliary obstruction and increased plasma unbound rocuronium because of free bilirubin competing with it for albumin binding. PMID:24147111

  9. Pyrene functionalized molecular beacon with pH-sensitive i-motif in a loop.

    PubMed

    Dembska, Anna; Juskowiak, Bernard

    2015-01-01

    In this work, we present a spectral characterization of pH-sensitive system, which combines the i-motif properties with the spatially sensitive fluorescence signal of pyrene molecules attached to hairpin ends. The excimer production (fluorescence max. ∼480 nm) by pyrene labels at the ends of the molecular beacon is driven by pH-dependent i-motif formation in the loop. To illustrate the performance and reversible work of our systems, we performed the experiments with repeatedly pH cycling between pH values of 7.5±0.3 and 6.5±0.3. The sensor gives analytical response in excimer-monomer switching mode in narrow pH range (1.5 pH units) and exhibits high pH resolution (0.1 pH unit). Copyright © 2015 Elsevier B.V. All rights reserved.

  10. The 40 and 50 GHz propagation experiments at the Rutherford Appleton Laboratory, UK, using the ITALSAT beacons

    NASA Technical Reports Server (NTRS)

    Woodroffe, J. M.; Davies, P. G.; Ladd, D. N.; Norbury, John R.

    1994-01-01

    This paper describes the current experimental program and future plans for the reception of transmissions from the 18.7, 39.6, and 49.5 GHz beacons from the ITALSAT satellite by the Radio Communications Research Unit at Rutherford Appleton Laboratory, UK. The Radio Communications Research Unit, which has had considerable experience in developing experimental millimetric equipment for propagation studies, has initiated the development of a single-channel receiver and a triple-channel receiver to measure propagation effects at 49.5 GHz and 39.6 GHz respectively. The initial location of the receivers will be at Chilbolton, Hampshire, UK.

  11. Small-airway obstruction and emphysema in chronic obstructive pulmonary disease.

    PubMed

    McDonough, John E; Yuan, Ren; Suzuki, Masaru; Seyednejad, Nazgol; Elliott, W Mark; Sanchez, Pablo G; Wright, Alexander C; Gefter, Warren B; Litzky, Leslie; Coxson, Harvey O; Paré, Peter D; Sin, Don D; Pierce, Richard A; Woods, Jason C; McWilliams, Annette M; Mayo, John R; Lam, Stephen C; Cooper, Joel D; Hogg, James C

    2011-10-27

    The major sites of obstruction in chronic obstructive pulmonary disease (COPD) are small airways (<2 mm in diameter). We wanted to determine whether there was a relationship between small-airway obstruction and emphysematous destruction in COPD. We used multidetector computed tomography (CT) to compare the number of airways measuring 2.0 to 2.5 mm in 78 patients who had various stages of COPD, as judged by scoring on the Global Initiative for Chronic Obstructive Lung Disease (GOLD) scale, in isolated lungs removed from patients with COPD who underwent lung transplantation, and in donor (control) lungs. MicroCT was used to measure the extent of emphysema (mean linear intercept), the number of terminal bronchioles per milliliter of lung volume, and the minimum diameters and cross-sectional areas of terminal bronchioles. On multidetector CT, in samples from patients with COPD, as compared with control samples, the number of airways measuring 2.0 to 2.5 mm in diameter was reduced in patients with GOLD stage 1 disease (P=0.001), GOLD stage 2 disease (P=0.02), and GOLD stage 3 or 4 disease (P<0.001). MicroCT of isolated samples of lungs removed from patients with GOLD stage 4 disease showed a reduction of 81 to 99.7% in the total cross-sectional area of terminal bronchioles and a reduction of 72 to 89% in the number of terminal bronchioles (P<0.001). A comparison of the number of terminal bronchioles and dimensions at different levels of emphysematous destruction (i.e., an increasing value for the mean linear intercept) showed that the narrowing and loss of terminal bronchioles preceded emphysematous destruction in COPD (P<0.001). These results show that narrowing and disappearance of small conducting airways before the onset of emphysematous destruction can explain the increased peripheral airway resistance reported in COPD. (Funded by the National Heart, Lung, and Blood Institute and others.).

  12. Biomechanical remodeling of obstructed guinea pig jejunum

    PubMed Central

    Zhao, Jingbo; Liao, Donghua; Yang, Jian; Gregersen, Hans

    2010-01-01

    Data on morphological and biomechanical remodeling are needed to understand the mechanisms behind intestinal obstruction. The effect of partial obstruction on mechanical properties with reference to the zero-stress state and on the histomorphological properties of the guinea pig small intestine was determined in this study. Partial obstruction and sham operation were surgically created in mid-jejunum of guinea pigs. The animals survived 2, 4, 7, and 14 days respectively. The age-matched guinea pigs that were not operated served as normal controls. The segment proximal to the obstruction site was used for histological analysis, no-load state and zero-stress state data, and distension test. The segment for distension was immersed in an organ bath and inflated to 10 cmH20. The outer diameter change during the inflation was monitored using a microscope with CCD camera. Circumferential stresses and strains were computed from the diameter, pressure and the zero-stress state data. The opening angle and absolute value of residual strain decreased (P<0.01 and P<0.001) whereas the wall thickness, wall cross-sectional area, and the wall stiffness increased after 7 days obstruction (P<0.05, P<0.01). Histologically, the muscle and submucosa layers, especially the circumferential muscle layer increased in thickness after obstruction. The opening angle and residual strain mainly depended on the thickness of the muscle layer whereas the wall stiffness mainly depended on the thickness of the submucosa layer. In conclusion, the histomorphological and biomechanical properties of small intestine (referenced for the first time to the zero-stress state) remodel proximal to the obstruction site in a time-dependent manner. PMID:20189575

  13. Investment Criteria for Airport Surveillance Radar, Air Traffic Control Radar Beacon System, and Automated Radar Terminal System (ASR/ATCRBS/ARTS)

    DTIC Science & Technology

    1983-05-01

    15 FIQGX 4 Tine Saved By ASR: 3 Mile vs. 7.5 Mile Separation 40 3 4 S10" 6 ;9 q4, ItI I ILI 10! i~o 2 _ _P𔃻_ _ P_ _ IFR HUM 16 :,.4eS _OE_ AT_...8217 16 . Abstract ""This report develops revised investment criteria for Airport Survoiillance Radar, Air Traffic Control Radar Beacon System, and...12 A. Introduction. .................... 1. 32 B. IFR Delay Reduction Benefits ...... ............. 13 C. Safety Benefits

  14. Preoperative Obstructive Sleep Apnea Screening in Gynecologic Oncology Patients.

    PubMed

    Harrison, Ross F; Medlin, Erin E; Petersen, Chase B; Rose, Stephen L; Hartenbach, Ellen M; Kushner, David M; Spencer, Ryan J; Rice, Laurel W; Al-Niaimi, Ahmed N

    2018-05-21

    Women with a gynecologic cancer tend to be older, obese, and postmenopausal, characteristics that are associated with an increased risk for obstructive sleep apnea. However, there is limited investigation regarding the condition's prevalence in this population or its impact on postoperative outcomes. In other surgical populations, patients with obstructive sleep apnea have been observed to be at increased risk for adverse postoperative events. To estimate the prevalence of obstructive sleep apnea among gynecologic oncology patients undergoing elective surgery and to investigate for a relationship between obstructive sleep apnea and postoperative outcomes. Patients referred to an academic gynecologic oncology practice were approached for enrollment in this prospective, observational study. Patients were considered eligible for study enrollment if they were scheduled for a non-emergent inpatient surgery and could provide informed consent. Enrolled patients were evaluated for a preexisting diagnosis of obstructive sleep apnea. Those without a prior diagnosis were screened using the validated, 4-item STOP [i.e. Snore loudly, daytime Tiredness, Observed apnea, elevated blood Pressure] questionnaire. All patients who screened positive for obstructive sleep apnea were referred for polysomnography. The primary outcome was the prevalence of women with obstructive sleep apnea or those who screened at high risk for the condition. Secondary outcomes examined the correlation between body mass index (kg/m 2 ) with obstructive sleep apnea and assessed for a relationship between obstructive sleep apnea and postoperative outcomes. Over a 22-month accrual period, 383 eligible patients were consecutively approached to participate in the study. A cohort of 260 patients were enrolled. A total of 33/260 patients (13%) were identified as having a previous diagnosis of obstructive sleep apnea. An additional 66/260 (25%) screened at risk for the condition using the STOP questionnaire. Of

  15. Drug-eluting stent in malignant biliary obstruction

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Ki; Jang, Sung Ill

    2012-10-01

    Endoscopic stent insertion is the treatment of choice for patients with malignant biliary obstruction. However, conventional stents enable only mechanical palliation of the obstruction, without any anti-tumor effects. Drugeluting stent (DES), which was first introduced in coronary artery disease, are currently under investigation for sustaining stent patency and prolonging patient survival by inhibiting tumor ingrowth in malignant biliary obstruction. Many factors affecting efficient drug delivery have been studied to determine how drugs with antitumor effects suppress tumor ingrowth, including the specific drugs incorporated, means of incorporating the drugs, mode of drug release, and stent structure. Advances have resulted in the construction of more effective non-vascular DES and ongoing clinical research. Non-vascular DES is expected to play a vital role in prolonging the survival of patients with malignant biliary obstruction.

  16. Nanomechanical DNA origami 'single-molecule beacons' directly imaged by atomic force microscopy

    PubMed Central

    Kuzuya, Akinori; Sakai, Yusuke; Yamazaki, Takahiro; Xu, Yan; Komiyama, Makoto

    2011-01-01

    DNA origami involves the folding of long single-stranded DNA into designed structures with the aid of short staple strands; such structures may enable the development of useful nanomechanical DNA devices. Here we develop versatile sensing systems for a variety of chemical and biological targets at molecular resolution. We have designed functional nanomechanical DNA origami devices that can be used as 'single-molecule beacons', and function as pinching devices. Using 'DNA origami pliers' and 'DNA origami forceps', which consist of two levers ~170 nm long connected at a fulcrum, various single-molecule inorganic and organic targets ranging from metal ions to proteins can be visually detected using atomic force microscopy by a shape transition of the origami devices. Any detection mechanism suitable for the target of interest, pinching, zipping or unzipping, can be chosen and used orthogonally with differently shaped origami devices in the same mixture using a single platform. PMID:21863016

  17. Unsupervised Indoor Localization Based on Smartphone Sensors, iBeacon and Wi-Fi.

    PubMed

    Chen, Jing; Zhang, Yi; Xue, Wei

    2018-04-28

    In this paper, we propose UILoc, an unsupervised indoor localization scheme that uses a combination of smartphone sensors, iBeacons and Wi-Fi fingerprints for reliable and accurate indoor localization with zero labor cost. Firstly, compared with the fingerprint-based method, the UILoc system can build a fingerprint database automatically without any site survey and the database will be applied in the fingerprint localization algorithm. Secondly, since the initial position is vital to the system, UILoc will provide the basic location estimation through the pedestrian dead reckoning (PDR) method. To provide accurate initial localization, this paper proposes an initial localization module, a weighted fusion algorithm combined with a k-nearest neighbors (KNN) algorithm and a least squares algorithm. In UILoc, we have also designed a reliable model to reduce the landmark correction error. Experimental results show that the UILoc can provide accurate positioning, the average localization error is about 1.1 m in the steady state, and the maximum error is 2.77 m.

  18. 33 CFR 329.10 - Existence of obstructions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... DEFENSE DEFINITION OF NAVIGABLE WATERS OF THE UNITED STATES § 329.10 Existence of obstructions. A stream... obstruction by means of artificial chutes. However, the question is ultimately a matter of degree, and it must...

  19. [Treatment of a patient with obstructive sleep apnea syndrome superimposed on chronic obstructive pulmonary disease].

    PubMed

    Mańkowski, M; Tulibacki, M; Koziej, M; Adach, W; Zieliński, J

    1995-01-01

    History of a middle aged obese male, presenting with severe obstructive sleep apnea (OSA) and chronic obstructive pulmonary disease (COPD) is described. Provisionally patient was started on CPAP and long-term domiciliary oxygen therapy (LTOT). OSA was successfully treated by surgical repair of nasal patency and partial uvulectomy. There was also remarkable improvement in ventilatory indices after steroid therapy. There was no further need for CPAP and LTOT.

  20. A CRISPR/molecular beacon hybrid system for live-cell genomic imaging.

    PubMed

    Wu, Xiaotian; Mao, Shiqi; Yang, Yantao; Rushdi, Muaz N; Krueger, Christopher J; Chen, Antony K

    2018-04-30

    The clustered regularly interspersed short palindromic repeat (CRISPR) gene-editing system has been repurposed for live-cell genomic imaging, but existing approaches rely on fluorescent protein reporters, making sensitive and continuous imaging difficult. Here, we present a fluorophore-based live-cell genomic imaging system that consists of a nuclease-deactivated mutant of the Cas9 protein (dCas9), a molecular beacon (MB), and an engineered single-guide RNA (sgRNA) harboring a unique MB target sequence (sgRNA-MTS), termed CRISPR/MB. Specifically, dCas9 and sgRNA-MTS are first co-expressed to target a specific locus in cells, followed by delivery of MBs that can then hybridize to MTS to illuminate the target locus. We demonstrated the feasibility of this approach for quantifying genomic loci, for monitoring chromatin dynamics, and for dual-color imaging when using two orthogonal MB/MTS pairs. With flexibility in selecting different combinations of fluorophore/quencher pairs and MB/MTS sequences, our CRISPR/MB hybrid system could be a promising platform for investigating chromatin activities.

  1. The Inversion of Ionospheric/plasmaspheric Electron Density From GPS Beacon Observations

    NASA Astrophysics Data System (ADS)

    Zou, Y. H.; Xu, J. S.; Ma, S. Y.

    It is a space-time 4-D tomography to reconstruct ionospheric/ plasmaspheric elec- tron density, Ne, from ground-based GPS beacon measurements. The mathematical foundation of such inversion is studied in this paper and some simulation results of reconstruction for GPS network observation are presented. Assuming reasonably a power law dependence of NE on time with an index number of 1-3 during one ob- servational time of GPS (60-90min.), 4-D inversion in consideration is reduced to a 3-D cone-beam tomography with incomplete projections. To see clearly the effects of the incompleteness on the quality of reconstruction for 3-D condition, we deduced theoretically the formulae of 3-D parallel-beam tomography. After establishing the mathematical basis, we adopt linear temporal dependence of NE and voxel elemental functions to perform simulation of NE reconstruction with the help of IRI90 model. Reasonable time-dependent 3-D images of ionosphere/ plasmasphere electron density distributions are obtained when taking proper layout of the GPS network and allowing variable resolutions in vertical.

  2. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    PubMed

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p < 0.001) and stent use for palliation (78.6% vs 56.3%; p < 0.001). Multivariate analysis indicated obstruction attributed to extracolonic malignancy and covered stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes

  3. Biliary obstruction - slideshow

    MedlinePlus

    ... ency/presentations/100199.htm Biliary obstruction - series—Normal anatomy To use the sharing ... Overview Bile is a digestive fluid secreted by the liver and stored in the gallbladder which normally is ...

  4. Prolonged survival in patients with breast cancer and a history of brain metastases: results of a preplanned subgroup analysis from the randomized phase III BEACON trial.

    PubMed

    Cortés, Javier; Rugo, Hope S; Awada, Ahmad; Twelves, Chris; Perez, Edith A; Im, Seock-Ah; Gómez-Pardo, Patricia; Schwartzberg, Lee S; Diéras, Veronique; Yardley, Denise A; Potter, David A; Mailliez, Audrey; Moreno-Aspitia, Alvaro; Ahn, Jin-Seok; Zhao, Carol; Hoch, Ute; Tagliaferri, Mary; Hannah, Alison L; O'Shaughnessy, Joyce

    2017-09-01

    Conventional chemotherapy has limited activity in patients with breast cancer and brain metastases (BCBM). Etirinotecan pegol (EP), a novel long-acting topoisomerase-1 inhibitor, was designed using advanced polymer technology to preferentially accumulate in tumor tissue including brain metastases, providing sustained cytotoxic SN38 levels. The phase 3 BEACON trial enrolled 852 women with heavily pretreated locally recurrent or metastatic breast cancer between 2011 and 2013. BEACON compared EP with treatment of physician's choice (TPC; eribulin, vinorelbine, gemcitabine, nab-paclitaxel, paclitaxel, ixabepilone, or docetaxel) in patients previously treated with anthracycline, taxane, and capecitabine, including those with treated, stable brain metastases. The primary endpoint, overall survival (OS), was assessed in a pre-defined subgroup of BCBM patients; an exploratory post hoc analysis adjusting for the diagnosis-specific graded prognostic assessment (GPA) index was also conducted. In the trial, 67 BCBM patients were randomized (EP, n = 36; TPC, n = 31). Treatment subgroups were balanced for baseline characteristics and GPA indices. EP was associated with a significant reduction in the risk of death (HR 0.51; P < 0.01) versus TPC; median OS was 10.0 and 4.8 months, respectively. Improvement in OS was observed in both poorer and better GPA prognostic groups. Survival rates at 12 months were 44.4% for EP versus 19.4% for TPC. Consistent with the overall BEACON population, fewer patients on EP experienced grade ≥3 toxicity (50 vs. 70%). The significant improvement in survival in BCBM patients provides encouraging data for EP in this difficult-to-treat subgroup of patients. A phase three trial of EP in BCBM patients is underway (ClinicalTrials.gov NCT02915744).

  5. Congenital ureteropelvic junction obstruction: human disease and animal models

    PubMed Central

    Klein, Julie; Gonzalez, Julien; Miravete, Mathieu; Caubet, Cécile; Chaaya, Rana; Decramer, Stéphane; Bandin, Flavio; Bascands, Jean-Loup; Buffin-Meyer, Bénédicte; Schanstra, Joost P

    2011-01-01

    Ureteropelvic junction (UPJ) obstruction is the most frequently observed cause of obstructive nephropathy in children. Neonatal and foetal animal models have been developed that mimic closely what is observed in human disease. The purpose of this review is to discuss how obstructive nephropathy alters kidney histology and function and describe the molecular mechanisms involved in the progression of the lesions, including inflammation, proliferation/apoptosis, renin–angiotensin system activation and fibrosis, based on both human and animal data. Also we propose that during obstructive nephropathy, hydrodynamic modifications are early inducers of the tubular lesions, which are potentially at the origin of the pathology. Finally, an important observation in animal models is that relief of obstruction during kidney development has important effects on renal function later in adult life. A major short-coming is the absence of data on the impact of UPJ obstruction on long-term adult renal function to elucidate whether these animal data are also valid in humans. PMID:20681980

  6. Small Bowel Obstruction Caused by Aloe vera Bezoars: A Case Report.

    PubMed

    Hong, In Taik; Cha, Jae Myung; Ki, Hye Jin; Kwak, Min Seob; Yoon, Jin Young; Shin, Hyun Phil; Jeoun, Jung Won; Choi, Sung Il

    2017-05-25

    Small bowel obstruction is a clinical condition commonly caused by postoperative adhesion, volvulus, intussusceptions, and hernia. Small bowel obstruction due to bezoars is clinically uncommon, accounting for approximately 2-4% of all obstructions. Computed tomography (CT) is a useful method in diagnosing the cause of small bowel obstruction. However, small bowel obstruction caused by bezoars may not be detected by an abdominal CT examination. Herein, we report a rare case of small bowel obstruction by Aloe vera bezoars, which were undetected by an abdominal CT. Phytobezoars should be included in the differential diagnosis of small bowel obstruction in patients with predisposing factors, such as excessive consumption of high-fiber food and diabetes.

  7. Obstructive Sleep Apnea Due To Extrathoracic Tracheomalacia

    PubMed Central

    Muzumdar, Hiren; Nandalike, K.; Bent, J.; Arens, Raanan

    2013-01-01

    We report obstructive sleep apnea in a 3-year-old boy with tracheomalacia secondary to tracheotomy that resolved after placement of a metallic stent in the region of tracheomalacia. The tracheal location of obstruction during sleep in this case contrasts with the usual location in the pharynx or, less often, the larynx. This case also demonstrates the utility of polysomnography in managing decannulation of tracheostomies. Citation: Muzumdar H; Nandalike K; Bent J; Arens R. Obstructive sleep apnea due to extrathoracic tracheomalacia. J Clin Sleep Med 2013;9(2):163–164. PMID:23372471

  8. [Helium-Oxigen (Heliox) mixture in airway obstruction

    PubMed

    Ulhôa, C A; Larner, L

    2000-01-01

    OBJECTIVE: Demonstrate the effectiveness and the good outcome of the patients treated with helium-oxygen (Heliox) mixture. This mixture (Heliox) has been used in patients with airway obstruction, from different ethiologies, who did not respond to a conventional treatment with oxygen. METHODS: Case report of five patients that received Heliox as treatment for airway obstruction. All of them had good results without side effects during the treatment. CONCLUSION: Heliox is a promising treatment for severe airway obstruction with good results in a short period of time, until the final treatment is established.

  9. Ultra-Stable Beacon Source for Laboratory Testing of Optical Tracking

    NASA Technical Reports Server (NTRS)

    Aso, Yoichi; Marka, Szabolcs; Kovalik, Joseph

    2008-01-01

    The ultra-stable beacon source (USBS) provides a laser-beam output with a very low angular jitter and can be used as an absolute angular reference to simulate a beacon in the laboratory. The laser is mounted on the top of a very short (approximately equal to 1 m) inverted pendulum (IP) with its optical axis parallel to the carbon fiber pendulum leg. The 85-cm, carbon fiber rods making up the leg are very lightweight and rigid, and are supported by a flex-joint at the bottom (see figure). The gimbal-mounted laser is a weight-adjustable load of about 1.5 kg with its center of rotation co-located with the center of percussion of the inverted pendulum. This reduces the coupling of transverse motion at the base of the pendulum to angular motion of the laser at the top. The inverted pendulum is mounted on a gimbal with its center of rotation coinciding with the pivot position of the inverted pendulum flexure joint. This reduces coupling of ground tilt at the inverted pendulum base to motion of the laser mounted at the top. The mass of the top gimbal is adjusted to give the pendulum a very low resonant frequency (approximately equal to 10 mHz) that filters transverse seismic disturbances from the ground where the base is attached. The motion of the IP is monitored by an optical-lever sensor. The laser light is reflected by the mirror on the IP, and then is detected by a quadrant photo-detector (QPD). The position of the beam spot on the QPD corresponds to the tilt of the IP. Damping of this motion is provided by two coil and magnet pairs. The bottom gimbal mount consists of two plates. The IP is mounted on the second plate. The first plate is supported by two posts through needles and can be rotated about the axis connecting the tips of the needles. The second plate hangs from the first plate and can be rotated about the axis perpendicular to the first plate. As a result, the second plate acts as a two-axis rotation stage. Its center of rotation is located at the

  10. Performance Evaluation of Energy-Autonomous Sensors Using Power-Harvesting Beacons for Environmental Monitoring in Internet of Things (IoT).

    PubMed

    Moiş, George Dan; Sanislav, Teodora; Folea, Silviu Corneliu; Zeadally, Sherali

    2018-05-25

    Environmental conditions and air quality monitoring have become crucial today due to the undeniable changes of the climate and accelerated urbanization. To efficiently monitor environmental parameters such as temperature, humidity, and the levels of pollutants, such as fine particulate matter (PM2.5) and volatile organic compounds (VOCs) in the air, and to collect data covering vast geographical areas, the development of cheap energy-autonomous sensors for large scale deployment and fine-grained data acquisition is required. Rapid advances in electronics and communication technologies along with the emergence of paradigms such as Cyber-Physical Systems (CPSs) and the Internet of Things (IoT) have led to the development of low-cost sensor devices that can operate unattended for long periods of time and communicate using wired or wireless connections through the Internet. We investigate the energy efficiency of an environmental monitoring system based on Bluetooth Low Energy (BLE) beacons that operate in the IoT environment. The beacons developed measure the temperature, the relative humidity, the light intensity, and the CO₂ and VOC levels in the air. Based on our analysis we have developed efficient sleep scheduling algorithms that allow the sensor nodes developed to operate autonomously without requiring the replacement of the power supply. The experimental results show that low-power sensors communicating using BLE technology can operate autonomously (from the energy perspective) in applications that monitor the environment or the air quality in indoor or outdoor settings.

  11. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope.

    PubMed

    Ching, Siok Siong; Tan, Yih Kai

    2012-09-07

    To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann(®) Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen

  12. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope

    PubMed Central

    Ching, Siok Siong; Tan, Yih Kai

    2012-01-01

    AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann® Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. RESULTS: A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant

  13. Obstructive sleep apnea and sedation in the endoscopy suite.

    PubMed

    Moos, Daniel D

    2006-01-01

    Patients with obstructive sleep apnea are at risk of mortality and morbidity related to the administration of sedatives, anesthetics, and opioids. Commonly employed sedatives and analgesics promote pharyngeal collapse and alter normal respiratory responses to obstruction and apnea. Literature concerning patients with obstructive sleep apnea undergoing moderate and deep sedation in the endoscopy suite is lacking. The purpose of this article is to provide the reader with a review of normal airway patency, the effects of obstructive sleep apnea on airway patency, and the impact that analgesics and sedatives may impart on the airway of patients with obstructive sleep apnea. The goal of this article is to increase awareness, stimulate discussions within the gastroenterological community, and encourage research regarding sedation in this at-risk population.

  14. Chronic obstructive pulmonary disease: knowing what we mean, meaning what we say.

    PubMed

    Joshi, J M

    2008-01-01

    Chronic obstructive pulmonary disease (COPD) is defined in several different ways using different criteria based on symptoms, physiological impairment and pathological abnormalities. While some use COPD to mean smoking related chronic airway disease, others include all disorders causing chronic airway obstruction. When COPD is used as a broad descriptive term, specific disorders that cause chronic airway obstruction remain under-diagnosed and the prevalence estimates vary considerably. The lack of agreement over the precise terminology and classification of COPD has resulted in widespread confusion. Terminology includes definition, diagnostic criteria, and a system for staging severity. Recently, COPD is defined more clearly and diagnosed using precise criteria that include tobacco smoking greater than 10 pack years, symptoms and airway obstruction on spirometry. A multi-dimensional severity grading system, the BODE (body mass index, obstruction, dyspnoea, and exercise tolerance) index has been designed to assess the respiratory and systemic expressions of COPD. This review proposes that the broad group of chronic disorders of the airways (with or without airway obstruction) be called chronic airway disease (CAD). The term COPD should be used exclusively for tobacco smoking related chronic airway disease. Chronic airway obstruction or obstructive lung disease may be used to define those conditions with airways obstruction caused by factors other than tobacco smoking. The aetiology may be appended to the label, for example, chronic airway obstruction/obstructive lung disease associated with bronchiectasis, chronic airway obstruction/obstructive lung disease associated with obliterative bronchiolitis or chronic airway obstruction/obstructive lung disease due to biomass fuel/occupational exposure.

  15. Obstructive Sleep Apnea

    MedlinePlus Videos and Cool Tools

    ... Apnea (OSA) Download Download the ebook for further information Obstructive sleep apnea (OSA) is a serious and ... that can create the necessary air passageway. The information provided here is not intended as a substitute ...

  16. Obstructive Sleep Apnea

    MedlinePlus

    ... more each hour, all night long. These disruptions impair your ability to reach the desired deep, restful ... with obstructive sleep apnea may also complain of memory problems, morning headaches, mood swings or feelings of ...

  17. Mitral stenosis and hypertrophic obstructive cardiomyopathy: An unusual combination.

    PubMed

    Hong, Joonhwa; Schaff, Hartzell V; Ommen, Steve R; Abel, Martin D; Dearani, Joseph A; Nishimura, Rick A

    2016-04-01

    Systolic anterior motion of mitral valve (MV) leaflets is a main pathophysiologic feature of left ventricular outflow tract (LVOT) obstruction in hypertrophic obstructive cardiomyopathy. Thus, restricted leaflet motion that occurs with MV stenosis might be expected to minimize outflow tract obstruction related to systolic anterior motion. From January 1993 through February 2015, we performed MV replacement and septal myectomy in 12 patients with mitral stenosis and hypertrophic obstructive cardiomyopathy at Mayo Clinic Hospital in Rochester, Minn. Preoperative data, echocardiographic images, operative records, and postoperative outcomes were reviewed. Mean (standard deviation) age was 70 (7.6) years. Preoperative mean (standard deviation) maximal LVOT pressure gradient was 75.0 (35.0) mm Hg; MV gradient was 13.7 (2.8) mm Hg. From echocardiographic images, 4 mechanisms of outflow tract obstruction were identified: systolic anterior motion without severe limitation in MV leaflet excursion, severe limitation in MV leaflet mobility with systolic anterior motion at the tip of the MV anterior leaflet, septal encroachment toward the LVOT, and MV displacement toward the LVOT by calcification. Mitral valve replacement and extended septal myectomy relieved outflow gradients in all patients, with no death or serious morbidity. Patients with mitral stenosis and hypertrophic obstructive cardiomyopathy have multiple LVOT obstruction mechanisms, and MV replacement may not be adequate treatment. We favor septal myectomy and MV replacement in this complex subset of hypertrophic obstructive cardiomyopathy. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Infectious mononucleosis presenting as upper airway obstruction.

    PubMed

    Jain, Vivek; Singhi, Sunit; Desai, Ravi V

    2003-01-01

    Upper airway obstruction though a common complication of infectious mononucleosis is rarely considered in differential diagnosis of stridor. We report a three-year-old child who had upper airway obstruction due to infectious mononucleosis, managed conservatively with oxygen, intravenous fluids and steroids.

  19. Obstructive sleep apnea, seizures, and childhood apraxia of speech.

    PubMed

    Caspari, Susan S; Strand, Edythe A; Kotagal, Suresh; Bergqvist, Christina

    2008-06-01

    Associations between obstructive sleep apnea and motor speech disorders in adults have been suggested, though little has been written about possible effects of sleep apnea on speech acquisition in children with motor speech disorders. This report details the medical and speech history of a nonverbal child with seizures and severe apraxia of speech. For 6 years, he made no functional gains in speech production, despite intensive speech therapy. After tonsillectomy for obstructive sleep apnea at age 6 years, he experienced a reduction in seizures and rapid growth in speech production. The findings support a relationship between obstructive sleep apnea and childhood apraxia of speech. The rather late diagnosis and treatment of obstructive sleep apnea, especially in light of what was such a life-altering outcome (gaining functional speech), has significant implications. Most speech sounds develop during ages 2-5 years, which is also the peak time of occurrence of adenotonsillar hypertrophy and childhood obstructive sleep apnea. Hence it is important to establish definitive diagnoses, and to consider early and more aggressive treatments for obstructive sleep apnea, in children with motor speech disorders.

  20. Systematic review: the influence of nasal obstruction on sleep apnea.

    PubMed

    Migueis, Debora Petrungaro; Thuler, Luiz Claudio Santos; Lemes, Lucas Neves de Andrade; Moreira, Chirlene Santos Souza; Joffily, Lucia; Araujo-Melo, Maria Helena de

    2016-01-01

    Obstructive sleep apnea syndrome (OSAS) is a common disorder that can lead to cardiovascular morbidity and mortality, as well as to metabolic, neurological, and behavioral consequences. It is currently believed that nasal obstruction compromises the quality of sleep when it results in breathing disorders and fragmentation of sleep. However, recent studies have failed to objectively associate sleep quality and nasal obstruction. The aim of this systematic review is to evaluate the influence of nasal obstruction on OSAS and polysomnographic indices associated with respiratory events. Eleven original articles published from 2003 to 2013 were selected, which addressed surgical and non-surgical treatment for nasal obstruction, performing polysomnography type 1 before and after the intervention. In most trials, nasal obstruction was not related to the apnea-hypopnea index (AHI), indicating no improvement in OSAS with reduction in nasal resistance. However, few researchers evaluated other polysomnography indices, such as the arousal index and rapid eye movement (REM) sleep percentage. These could change with nasal obstruction, since it is possible that the nasal obstruction does not completely block the upper airways, but can increase negative intrathoracic pressure, leading to sleep fragmentation. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  1. Removal of obstructing T-tube and stabilization of the airway.

    PubMed

    Athavale, Sanjay M; Dang, Jennifer; Rangarajan, Sanjeet; Garrett, Gaelyn

    2011-05-01

    Although they are extremely effective in maintaining tracheal and subglottic patency, T-tubes themselves can result in airway obstruction from plugging. Many practitioners educate patients on placing a small (5.0) endotracheal tube (ETT) through the tracheal limb of the T-tube if they develop airway obstruction. Unfortunately, this can be a difficult task to complete during acute airway obstruction. In this article, we describe a simple set of steps for rapid relief of airway obstruction and stabilization of the airway in the event of T-tube obstruction. This method requires removal of the T-tube with a Kelly clamp and stabilization of the airway with a tracheostomy tube. Although it is simple, we hope that this technique will prevent morbidity and mortality from acute airway obstructions related to T-tubes. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  2. 14 CFR 151.91 - Removal of obstructions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Removal of obstructions. 151.91 Section 151.91 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRPORTS FEDERAL AID TO AIRPORTS Project Programming Standards § 151.91 Removal of obstructions. (a) The...

  3. 14 CFR 151.91 - Removal of obstructions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Removal of obstructions. 151.91 Section 151.91 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRPORTS FEDERAL AID TO AIRPORTS Project Programming Standards § 151.91 Removal of obstructions. (a) The...

  4. 14 CFR 151.91 - Removal of obstructions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Removal of obstructions. 151.91 Section 151.91 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRPORTS FEDERAL AID TO AIRPORTS Project Programming Standards § 151.91 Removal of obstructions. (a) The...

  5. 14 CFR 151.91 - Removal of obstructions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Removal of obstructions. 151.91 Section 151.91 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRPORTS FEDERAL AID TO AIRPORTS Project Programming Standards § 151.91 Removal of obstructions. (a) The...

  6. Pulmonary distribution of an inhaled radioaerosol in obstructive pulmonary disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, M.S.; Goodwin, D.A.

    1976-03-01

    Pulmonary distribution of an inhaled radioaerosol was analyzed in 20 cases of chronic obstructive pulmonary disease (COPD) and 8 of other OPD. Nonciliary/ciliary partition of the distribution correlated with the severity of airway obstruction and approximated 3 : 1 in mild and 1 : 3 in very severe obstruction. In nuclear images, the distribution featured contrast abnormalities of hyperdeposition and hypodeposition. Intense hyperdeposition most commonly occurred in hilar and perihilar large airways. In isolated instances, hyperdeposition almost certainly occurred focally at sites of partial bronchial obstruction and diffusely by expiratory trapping; hypodeposition occurred distally to bronchial obstruction and in areasmore » of parenchymal loss. (auth)« less

  7. Obstructive ureteropathy following radiation therapy for carcinoma of the cervix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parliament, M.; Genest, P.; Girard, A.

    1989-05-01

    Between January 1959 and December 1986, 10 of 328 patients (3%) treated with curative intent using primary radiation therapy for carcinoma of the cervix developed obstructive ureteropathy due to fibrosis. The mean age of the patients with obstructive ureteropathy was 45 years and the median time to obstruction was 26 months. The obstruction was unilateral in 8 cases and involved the parametrial portion of the ureter in at least 5 cases. No predisposing risk factor was found to be associated with the development of obstructive ureteropathy. After corrective surgery, renal function remained normal in 8 patients, and resolution of themore » hydronephrosis occurred in 4 patients.« less

  8. Long-stem shaped multifunctional molecular beacon for highly sensitive nucleic acids determination via intramolecular and intermolecular interactions based strand displacement amplification.

    PubMed

    Xu, Jianguo; Zheng, Tingting; Le, Jingqing; Jia, Lee

    2017-11-20

    Occurrence and application of oligonucleotide probes have promoted great progress in the biochemical analysis field due to their unique biological and chemical properties. In this work, a long-stem shaped multifunctional molecular beacon (LS-MMB) that is responsive to a cancer-related gene, p53, is well-prepared. By designing the probe with long-paired bases at its two ends and short-paired bases between the middle region and the 3' end, the LS-MMB is intelligently endowed with the ability to recognize the target analyte, serve as the polymerization primer/template, and signal the hybridization event synchronously, which is distinctly advantageous over the traditional molecular beacons (MBs). Moreover, it is excitingly found that the LS-MMB can be employed to exert intramolecular and intermolecular interactions for strand displacement amplification (SDA) without the involvement of any assistant probes; this therapy results in a really easy and rapid sensing system that provides an extremely low background noise and high target output signal. In this case, an excellent sensitivity and specificity to detect target gene down to picomolar level and resolution to even one nucleotide variation are achieved, respectively. In addition, the application potential for real genomic DNA analysis is realized. We envision that the probe of LS-MMB can act as a universal platform for biosensing and biomedical research.

  9. [Correlation between obstructive apnea syndrome and difficult airway in ENT surgery].

    PubMed

    Pera, Marcia Hiray; Tardelli, Maria Angela; Novo, Neil Ferreira; Juliano, Yara; Silva, Helga Cristina Almeida da

    2017-12-21

    ENT patients with obstructive sleep apnea syndrome have a tendency of collapsing the upper airways in addition to anatomical obstacles. Obstructive sleep apnea syndrome is related to the increased risk of difficult airway and also increased perioperative complications. In order to identify these patients in the preoperative period, the STOP Bang questionnaire has been highlighted because it is summarized and easy to apply. Evaluate through the STOP Bang questionnaire whether patients undergoing ENT surgery with a diagnosis of obstructive sleep apnea syndrome have a higher risk of complications, particularly the occurrence of difficult airway. Measurements of anatomical parameters for difficult airway and questionnaire application for clinical prediction of obstructive sleep apnea syndrome were performed in 48 patients with a previous polysomnographic study. The sample detected difficult airway in about 18.7% of patients, all of them with obstructive sleep apnea syndrome. This group had older age, cervical circumference > 40cm, ASA II and Cormack III/IV. Patients with obstructive sleep apnea syndrome had higher body mass index, cervical circumference, and frequent apnea. In subgroup analysis, the group with severe obstructive sleep apnea syndrome showed a significantly higher SB score compared to patients without this syndrome or with a mild/moderate obstructive sleep apnea syndrome. The STOP Bang questionnaire was not able to predict difficult airway and mild obstructive sleep apnea syndrome, but it identified marked obstructive sleep apnea syndrome. All patients with difficult airway had moderate and marked obstructive sleep apnea syndrome, although this syndrome did not involve difficult airway. The variables Cormack III/IV and BMI greater than 35 Kg.m -2 were able to predict difficult airway and obstructive sleep apnea syndrome, respectively. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  10. Greater effect of stroke thrombolysis in the presence of arterial obstruction.

    PubMed

    De Silva, Deidre A; Churilov, Leonid; Olivot, Jean-Marc; Christensen, Soren; Lansberg, Maarten G; Mlynash, Michael; Campbell, Bruce C V; Desmond, Patricia; Straka, Matus; Bammer, Roland; Albers, Gregory W; Davis, Stephen M; Donnan, Geoffrey A

    2011-10-01

    Recanalization of arterial obstruction is associated with improved clinical outcomes. There are no controlled data demonstrating whether arterial obstruction status predicts the treatment effect of intravenous (IV) tissue plasminogen activator (tPA). We aimed to determine if the presence of arterial obstruction improves the treatment effect of IV tPA over placebo in attenuating infarct growth. We analyzed 175 ischemic stroke patients treated in the 3-6 hour time window from the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET) trial (randomized to IV tPA or placebo) and Diffusion and perfusion imaging Evaluation For Understanding Stroke Evolution (DEFUSE) study (all treated with IV tPA). Infarct growth was calculated as the difference between baseline diffusion-weighted imaging (DWI) and final T2 lesion volumes. Baseline arterial obstruction of large intracranial arteries was graded on magnetic resonance angiography (MRA). Among the 116 patients with adequate baseline MRA and final lesion assessment, 72 had arterial obstruction (48 tPA, 24 placebo) and 44 no arterial obstruction (33 tPA, 11 placebo). Infarct growth was lower in the tPA than placebo group (median difference 26ml, 95% confidence interval [CI], 1-50) in patients with arterial obstruction, but was similar in patients with no arterial obstruction (median difference 5ml, 95%CI, -3 to 9). Infarct growth attenuation with tPA over placebo treatment was greater among patients with arterial obstruction than those without arterial obstruction by a median of 32ml (95%CI, 21-43, p < 0.001). The treatment effect of IV tPA over placebo was greater with baseline arterial obstruction, supporting arterial obstruction status as a consideration in selecting patients more likely to benefit from IV thrombolysis. Copyright © 2011 American Neurological Association.

  11. Timing Matters: Circadian Rhythm in Sepsis, Obstructive Lung Disease, Obstructive Sleep Apnea, and Cancer

    PubMed Central

    Truong, Kimberly K.; Lam, Michael T.; Grandner, Michael A.; Sassoon, Catherine S.

    2016-01-01

    Physiological and cellular functions operate in a 24-hour cyclical pattern orchestrated by an endogenous process known as the circadian rhythm. Circadian rhythms represent intrinsic oscillations of biological functions that allow for adaptation to cyclic environmental changes. Key clock genes that affect the persistence and periodicity of circadian rhythms include BMAL1/CLOCK, Period 1, Period 2, and Cryptochrome. Remarkable progress has been made in our understanding of circadian rhythms and their role in common medical conditions. A critical review of the literature supports the association between circadian misalignment and adverse health consequences in sepsis, obstructive lung disease, obstructive sleep apnea, and malignancy. Circadian misalignment plays an important role in these disease processes and can affect disease severity, treatment response, and survivorship. Normal inflammatory response to acute infections, airway resistance, upper airway collapsibility, and mitosis regulation follows a robust circadian pattern. Disruption of normal circadian rhythm at the molecular level affects severity of inflammation in sepsis, contributes to inflammatory responses in obstructive lung diseases, affects apnea length in obstructive sleep apnea, and increases risk for cancer. Chronotherapy is an underused practice of delivering therapy at optimal times to maximize efficacy and minimize toxicity. This approach has been shown to be advantageous in asthma and cancer management. In asthma, appropriate timing of medication administration improves treatment effectiveness. Properly timed chemotherapy may reduce treatment toxicities and maximize efficacy. Future research should focus on circadian rhythm disorders, role of circadian rhythm in other diseases, and modalities to restore and prevent circadian disruption. PMID:27104378

  12. Timing Matters: Circadian Rhythm in Sepsis, Obstructive Lung Disease, Obstructive Sleep Apnea, and Cancer.

    PubMed

    Truong, Kimberly K; Lam, Michael T; Grandner, Michael A; Sassoon, Catherine S; Malhotra, Atul

    2016-07-01

    Physiological and cellular functions operate in a 24-hour cyclical pattern orchestrated by an endogenous process known as the circadian rhythm. Circadian rhythms represent intrinsic oscillations of biological functions that allow for adaptation to cyclic environmental changes. Key clock genes that affect the persistence and periodicity of circadian rhythms include BMAL1/CLOCK, Period 1, Period 2, and Cryptochrome. Remarkable progress has been made in our understanding of circadian rhythms and their role in common medical conditions. A critical review of the literature supports the association between circadian misalignment and adverse health consequences in sepsis, obstructive lung disease, obstructive sleep apnea, and malignancy. Circadian misalignment plays an important role in these disease processes and can affect disease severity, treatment response, and survivorship. Normal inflammatory response to acute infections, airway resistance, upper airway collapsibility, and mitosis regulation follows a robust circadian pattern. Disruption of normal circadian rhythm at the molecular level affects severity of inflammation in sepsis, contributes to inflammatory responses in obstructive lung diseases, affects apnea length in obstructive sleep apnea, and increases risk for cancer. Chronotherapy is an underused practice of delivering therapy at optimal times to maximize efficacy and minimize toxicity. This approach has been shown to be advantageous in asthma and cancer management. In asthma, appropriate timing of medication administration improves treatment effectiveness. Properly timed chemotherapy may reduce treatment toxicities and maximize efficacy. Future research should focus on circadian rhythm disorders, role of circadian rhythm in other diseases, and modalities to restore and prevent circadian disruption.

  13. Usefulness of Ultrasonography and Cortical Transit Time to Differentiate Nonobstructive From Obstructive Dilatation in the Management of Prenatally Detected Pelvic Ureteric Junction Like Obstruction.

    PubMed

    Sharma, Gyanendra; Sharma, Anshu

    2017-12-01

    To differentiate a nonobstructive dilatation from an obstructive dilatation in prenatally detected presumed pelvi-ureteric junction obstruction so that intervention can be planned before irreversible damage can occur to the renal unit. From January 2012 to December 2016, all patients with prenatally detected or asymptomatic incidentally detected presumed pelvi-ureteric junction obstruction were evaluated by ultrasonography and renogram. The anteroposterior diameter of the renal pelvis was measured in supine and prone position. Presence of calyceal dilatation in prone position was noted. They were categorized into obstructed, nonobstructed, and equivocal groups based on sonography findings. The differential renal function and the cortical transit time (CTT) was calculated and compared with the sonography groups. Of the 98 patients, 72 were in the obstructed, 18 were in the nonobstructed, and 8 were in the equivocal category. All except 1 in the nonobstructed category had a function of >40% with CTT of <3 minutes. Seventy patients in the obstructed category had a CTT of >3 minutes, whereas 61 had function <40% on initial evaluation. Eleven patients in the obstructed category with an initial function of >40% had CTT of >3 minutes. All of them showed increasing hydronephrosis and deterioration of function during follow-up, necessitating pyeloplasty. All patients in the equivocal group had function >40% and CTT <3 minutes. Ultrasonography along with CTT can help to differentiate nonobstructive from obstructive dilatation. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Subtotal obstruction of the male reproductive tract.

    PubMed

    Dohle, G R; van Roijen, J H; Pierik, F H; Vreeburg, J T M; Weber, R F A

    2003-03-01

    Bilateral obstruction of the male reproductive tract is suspected in men with azoospermia, normal testicular volume and normal FSH. A testicular biopsy is required to differentiate between an obstruction and a testicular insufficiency. Unilateral or subtotal bilateral obstructions and epididymal dysfunction may cause severe oligozoospermia in men with a normal spermatogenesis. However, information on spermatogenesis in oligozoospermic men is lacking, since testicular biopsy is not routinely performed. Men with a sperm concentration of <1 x 10(6) spermatozoa/ml were investigated for possible partial obstruction by performing a testicular biopsy under local anaesthesia. Spermatogenesis was determined by the Johnsen scoring method. A testicular biopsy was performed in 78 men with severe oligozoospermia. The medical history showed male accessory gland infection in 12.8%, previous hernia repair in 14.1% and a history of cryptorchidism in 12.8%. A normal or slightly disturbed spermatogenesis (Johnsen score >8) was present in 39/78 (50%) of the men. Hernia repair occurred more often in men with normal spermatogenesis. A varicocele was predominantly seen in men with a disturbed spermatogenesis. FSH was significantly lower ( P<0.0001) in men with normal spermatogenesis. Subtotal obstruction of the male reproductive tract is a frequent cause of severe oligozoospermia in men with a normal testicular volume and a normal FSH. In other cases, an epididymal dysfunction might explain the oligozoospermia in men with a normal testicular biopsy score.

  15. Direct detection of circulating free DNA extracted from serum samples of breast cancer using locked nucleic acid molecular beacon.

    PubMed

    Gui, Zhen; Wang, Quanbo; Li, Jinchang; Zhu, Mingchen; Yu, Lili; Xun, Tang; Yan, Feng; Ju, Huangxian

    2016-07-01

    As an emerging noninvasive blood biomarker, circulating free DNA (cfDNA) can be utilized to assess diagnosis, progression and evaluate prognosis of cancer. However, cfDNAs are not "naked", they can be part of complexes, or are bound to the surface of the cells via proteins, which make the detection more challenging. Here, a simple method for the detection of Ubiquitin-like with PHD and ring finger domains 1 (UHRF1) DNA exacted from serum of breast cancer (BC) has been developed using a novel locked nucleic acid molecular beacon (LNA-MB). In order to enhance the stability and detection efficiency of the probe in biofluids, we design a shared-stem molecular beacon containing a 27-mer loop and a 4-mer stem with DNA/LNA alternating bases. The fluorescence is released in the presence of target. The detection procedure is simple and can be completed within 1h. This method shows a sensitive response to UHRF1 DNA with a dynamic range of 3 orders of magnitude. The limit of detection is 11nM (S/N=3) with excellent selectivity. It can discriminate UHRF1 DNA from three-base mismatched DNA with a high specificity. More importantly, this method can distinguish the expression of serum UHRF1 DNA among 5 breast cancer patients and 5 healthy controls. The mentioned superiority may suggest that this assay can be served as a promising noninvasive detection tool for early BC diagnosis and monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. In vitro RNA release from a human rhinovirus monitored by means of a molecular beacon and chip electrophoresis.

    PubMed

    Weiss, Victor U; Bliem, Christina; Gösler, Irene; Fedosyuk, Sofiya; Kratzmeier, Martin; Blaas, Dieter; Allmaier, Günter

    2016-06-01

    Liquid-phase electrophoresis either in the classical capillary format or miniaturized (chip CE) is a valuable tool for quality control of virus preparations and for targeting questions related to conformational changes of viruses during infection. We present an in vitro assay to follow the release of the RNA genome from a human rhinovirus (common cold virus) by using a molecular beacon (MB) and chip CE. The MB, a probe that becomes fluorescent upon hybridization to a complementary sequence, was designed to bind close to the 3' end of the viral genome. Addition of Trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid), a well-known additive for reduction of bleaching and blinking of fluorophores in fluorescence microscopy, to the background electrolyte increased the sensitivity of our chip CE set-up. Hence, a fast, sensitive and straightforward method for the detection of viral RNA is introduced. Additionally, challenges of our assay will be discussed. In particular, we found that (i) desalting of virus preparations prior to analysis increased the recorded signal and (ii) the MB-RNA complex signal decreased with the time of virus storage at -70 °C. This suggests that 3'-proximal sequences of the viral RNA, if not the whole genome, underwent degradation during storage and/or freezing and thawing. In summary, we demonstrate, for two independent virus batches, that chip electrophoresis can be used to monitor MB hybridization to RNA released upon incubation of the native virus at 56 °C. Graphical Abstract Schematic of the study strategy: RNA released from HRV-A2 is detected by chip electrophoresis through the increase in fluorescence after genom complexation to a cognate molecular beacon.

  17. Development of a high-throughput detection system for HIV-1 using real-time NASBA based on molecular beacons

    NASA Astrophysics Data System (ADS)

    van Beuningen, Rinie; Marras, Salvatore A.; Kramer, Fred R.; Oosterlaken, Tom; Weusten, Jos; Borst, G.; van de Wiel, Paul

    2001-04-01

    HIV-1 viral load assays require accuracy and sensitivity at low RNA levels with the capability to detect all subtypes. Furthermore, the assay should be easy to perform and fast to be useful for routine diagnostics. In order to meet these demands we have combined isothermal NASBA amplification with molecular beacon probes for real-time detection and quantitation of HIV-1 RNA. Quantitation is based on co-amplification of the HIV-1 RNA in the clinical sample and a synthetic calibrator RNA which is amplified by the same primer set but detected with a differently labeled molecular beacon. The entire procedure is simple and analysis of 48 samples requires less than 1» hours with minimal hands-on time. A fluorescent plate reader is used for real-time detection and isothermal amplification. The linearity and precision of the assay was determined with the VQC HIV-1 type B standard of the Central Laboratory of the Dutch Red Cross Blood Banks, The Netherlands. Sensitivity was shown to be 50 copies per ml (cps/ml). The average assay precision was 0,19 log10 over a range of 100-300,000 cps/ml tested at nine concentrations. The linearity of dilution series of 15 cultured HIV-1 gag clades A-H was shown. The specificity was 100% on non HIV-1 samples HIV-2, HTLV-1 and HTLV-2. The assay robustness in terms of valid results was 99%. In conclusion, the new real-time NASBA assay meets state-of-the-art HIV-1 viral load performance requirements combined with a high level of user convenience.

  18. A chaotic micromixer using obstruction-pairs

    NASA Astrophysics Data System (ADS)

    Park, Jang Min; Duck Seo, Kyoung; Kwon, Tai Hun

    2010-01-01

    A micromixer is one of the most important components for a chemical and/or diagnostic analysis in microfluidic devices such as a micro-total-analysis-system and a lab-on-a-chip. In this paper, a novel chaotic micromixer is developed in a simple design by introducing obstruction-pairs on the bottom of a microchannel. An obstruction-pair, which is composed of two hexahedron blocks arranged in an asymmetric manner, can induce a rotational flow along the down-channel direction due to the anisotropy of flow resistance. By utilizing this characteristic of the obstruction-pair, four mixing units are designed in such a way that three obstruction-pairs induce three rotational flows which result in a down-welling and a hyperbolic point in the channel cross-section. There can be a variety of micromixer geometries by arranging the mixing units in various sequences along the microchannel, and their mixing performances will differ from each other due to different flow characteristics. In this regard, numerical investigations are carried out to predict and characterize the mixing performances of various micromixers. Also experimental verifications are carried out by a flow visualization technique using phenolphthalein and sodium hydroxide solutions in a polydimethylsiloxane-based micromixer.

  19. Analysis of electrocardiogram in chronic obstructive pulmonary disease patients.

    PubMed

    Lazović, Biljana; Svenda, Mirjana Zlatković; Mazić, Sanja; Stajić, Zoran; Delić, Marina

    2013-01-01

    Chronic obstructive pulmonary disease is the fourth leading cause of mortality worldwide. It is defined as a persistent airflow limitation usually progressive and not fully reversible to treatment. The diagnosis of chronic obstructive pulmonary disease and severity of disease is confirmed by spirometry. Chronic obstructive pulmonary disease produces electrical changes in the heart which shows characteristic electrocardiogram pattern. The aim of this study was to observe and evaluate diagnostic values of electrocardiogram changes in chronic obstructive pulmonary disease patients with no other comorbidity. We analyzed 110 electrocardiogram findings in clinically stable chronic obstructive pulmonary disease patients and evaluated the forced expiratory volume in the first second, ratio of forces expiratory volume in the first second to the fixed vital capacity, chest radiographs and electrocardiogram changes such as p wave height, QRS axis and voltage, right bundle branch block, left bundle branch block, right ventricular hypertrophy, T wave inversion in leads V1-V3, S1S2S3 syndrome, transition zone in praecordial lead and QT interval. We found electrocardiogram changes in 64% patients, while 36% had normal electrocardiogram. The most frequent electrocardiogram changes observed were transition zone (76.36%) low QRS (50%) and p pulmonale (14.54%). Left axis deviation was observed in 27.27% patients. Diagnostic values of electrocardiogram in patients with chronic obstructive pulmonary disease suggest that chronic obstructive pulmonary disease patients should be screened electrocardiographically in addition to other clinical investigations.

  20. Video Altimeter and Obstruction Detector for an Aircraft

    NASA Technical Reports Server (NTRS)

    Delgado, Frank J.; Abernathy, Michael F.; White, Janis; Dolson, William R.

    2013-01-01

    Video-based altimetric and obstruction detection systems for aircraft have been partially developed. The hardware of a system of this type includes a downward-looking video camera, a video digitizer, a Global Positioning System receiver or other means of measuring the aircraft velocity relative to the ground, a gyroscope based or other attitude-determination subsystem, and a computer running altimetric and/or obstruction-detection software. From the digitized video data, the altimetric software computes the pixel velocity in an appropriate part of the video image and the corresponding angular relative motion of the ground within the field of view of the camera. Then by use of trigonometric relationships among the aircraft velocity, the attitude of the camera, the angular relative motion, and the altitude, the software computes the altitude. The obstruction-detection software performs somewhat similar calculations as part of a larger task in which it uses the pixel velocity data from the entire video image to compute a depth map, which can be correlated with a terrain map, showing locations of potential obstructions. The depth map can be used as real-time hazard display and/or to update an obstruction database.

  1. Migrating gallstone: from Bouveret's syndrome to distal small bowel obstruction.

    PubMed

    Yau, Kwok-Kay; Siu, Wing-Tai; Tsui, Ka-Kin

    2006-06-01

    Gallstone ileus is an uncommon cause of small bowel obstruction. When the gallstone lodges inside the duodenum and causes gastric outlet obstruction, it is termed Bouveret's syndrome. However, it is rather unusual to seen the evolution of a migrating gallstone (from duodenum to distal small bowel) in a patient during the same hospital admission. We report a case of gallstone ileus from the initial presentation of gastric outlet obstruction to the development of distal small bowel obstruction within the same hospital admission, and its total laparoscopic treatment.

  2. The Effect of Slipstream Obstructions on Air Propellers

    NASA Technical Reports Server (NTRS)

    Lesley, E P; Woods, B M

    1924-01-01

    The screw propeller on airplanes is usually placed near other objects, and hence its performance may be modified by them. Results of tests on propellers free from slip stream obstructions, both fore and aft, are therefore subject to correction, for the effect of such obstructions and the purpose of the investigation was to determine the effect upon the thrust and torque coefficients and efficiency, for previously tested air propellers, of obstructions placed in the slip stream, it being realized that such previous tests had been conducted under somewhat ideal conditions that are impracticable of realization in flight. Simple geometrical forms were used for the initial investigation. Such forms offered the advantage of easy, exact reproduction at another time or in other laboratories, and it was believed that the effects of obstructions usually encountered might be deduced or surmise from those chosen.

  3. 33 CFR 67.25-5 - Obstruction lights.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES Class âBâ Requirements § 67.25-5 Obstruction lights. (a) The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this part and shall be of sufficient candlepower as to be visible at a distance of at least three nautical...

  4. 33 CFR 67.25-5 - Obstruction lights.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES Class âBâ Requirements § 67.25-5 Obstruction lights. (a) The obstruction lights shall be white lights as prescribed in Subpart 67.05 of this part and shall be of sufficient candlepower as to be visible at a distance of at least three nautical...

  5. Real-time monitoring of disintegration activity of catalytic core domain of HIV-1 integrase using molecular beacon.

    PubMed

    Zhang, Da-wei; Zhao, Ming-ming; He, Hong-qiu; Guo, Shun-xing

    2013-09-15

    HIV-1 integrase, an essential enzyme for retroviral replication, is a validated target for anti-HIV therapy development. The catalytic core domain of integrase (IN-CCD) is capable of catalyzing disintegration reaction. In this work, a hairpin-shaped disintegration substrate was designed and validated by enzyme-linked immunosorbent assay; a molecular beacon-based assay was developed for disintegration reaction of IN-CCD. Results showed that the disintegration substrate could be recognized and catalyzed by IN-CCD, and the disintegration reaction can be monitored according to the increase of fluorescent signal. The assay can be applied to real-time detection of disintegration with advantages of simplicity, high sensitivity, and excellent specificity. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Obstructive sleep apnea - adults

    MedlinePlus

    ... SM. Obstructive sleep apnea: clinical features, evaluation, and principles of management. In: Kryger M, Roth T, Dement WC, eds. Principles and Practice of Sleep Medicine . 6th ed. Philadelphia, ...

  7. Sharp metric obstructions for quasi-Einstein metrics

    NASA Astrophysics Data System (ADS)

    Case, Jeffrey S.

    2013-02-01

    Using the tractor calculus to study smooth metric measure spaces, we adapt results of Gover and Nurowski to give sharp metric obstructions to the existence of quasi-Einstein metrics on suitably generic manifolds. We do this by introducing an analogue of the Weyl tractor W to the setting of smooth metric measure spaces. The obstructions we obtain can be realized as tensorial invariants which are polynomial in the Riemann curvature tensor and its divergence. By taking suitable limits of their tensorial forms, we then find obstructions to the existence of static potentials, generalizing to higher dimensions a result of Bartnik and Tod, and to the existence of potentials for gradient Ricci solitons.

  8. Obstructive sleep apnea syndrome and growth failure.

    PubMed

    Esteller, E; Villatoro, J C; Agüero, A; Lopez, R; Matiñó, E; Argemi, J; Girabent-Farrés, M

    2018-05-01

    Obstructive sleep apnea syndrome is a common problem among children and is recognized as a cause of significant medical morbidity. Since the 1980s, it has been suggested that obstructive sleep apnea syndrome is a risk factor for growth failure in children. In many cases, it has been shown that growth failure is reversible once the obstructive sleep apnea syndrome is resolved. The objectives of this study were to analyze and compare growth failure prevalence in a Mediterranean population of children with obstructive sleep apnea syndrome and healthy children matched in age and sex, and to assess the effectiveness of tonsillectomy and adenoidectomy in resolving growth retardation. We compared 172 children with obstructive sleep apnea syndrome (apnea-hypopnea index ≥ 3) who had undergone tonsillectomy and adenoidectomy with 172 healthy controls in terms of key anthropometric parameters. Most of the criteria used for growth failure were higher to a statistically significant degree in the study group vs the control group: height-for-age ≤ 3rd percentile (7.56% vs 2.91%; p = 0.044), weight-for-age ≤ 5th percentile (9.30% vs 2.33%; p = 0.005), weight-for-age ≤ 3rd percentile (8.14% vs 2.33%; p = 0.013) and height and/or weight for-age ≤ 5th percentile (13.95% vs 5.81%; p = 0.009). The height-for-age ≤ 5th percentile was almost at the limit of statistical significance (8.72% for the study group vs 4.65% for the control group; p = 0.097). At one-year post-surgery follow-up, 10 of 15 children with height-for-age ≤ 5th percentile had achieved catch-up growth (66.6%), and 14 of 24 children with height- and/or weight-for-age ≤ 5th percentile had normalized growth (58.33%). For children with failure to thrive or who have growth failure, physicians should consider the possibility of obstructive sleep apnea. A significant number of children with obstructive sleep apnea concurrent with growth failure could benefit from

  9. Positive predictive value of cholescintigraphy in common bile duct obstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lecklitner, M.L.; Austin, A.R.; Benedetto, A.R.

    1986-09-01

    Technetium-99m DISIDA imaging was employed in 400 patients to differentiate obstruction of the common bile duct from medical and other surgical causes of hyperbilirubinemia. Sequential anterior images demonstrated variable degrees of liver uptake, yet there was no evidence of intrabiliary or extrabiliary radioactivity for at least 4 hr after injection in 25 patients. Twenty-three patients were surgically documented to have complete obstruction of the common bile duct. One patient had hepatitis, and another had sickle cell crisis without bile duct obstruction. The remaining patients had either partial or no obstruction of the common bile duct. We conclude that the presencemore » of liver uptake without evident biliary excretion by 4 hr on cholescintigraphy is highly sensitive and predictive of total obstruction of the common bile duct.« less

  10. Radiological interventions in malignant biliary obstruction

    PubMed Central

    Madhusudhan, Kumble Seetharama; Gamanagatti, Shivanand; Srivastava, Deep Narayan; Gupta, Arun Kumar

    2016-01-01

    Malignant biliary obstruction is commonly caused by gall bladder carcinoma, cholangiocarcinoma and metastatic nodes. Percutaneous interventions play an important role in managing these patients. Biliary drainage, which forms the major bulk of radiological interventions, can be palliative in inoperable patients or pre-operative to improve liver function prior to surgery. Other interventions include cholecystostomy and radiofrequency ablation. We present here the indications, contraindications, technique and complications of the radiological interventions performed in patients with malignant biliary obstruction. PMID:27247718

  11. Forced oscillometry track sites of airway obstruction in bronchial asthma.

    PubMed

    Hafez, Manal Refaat; Abu-Bakr, Samiha Mohamed; Mohamed, Alyaa Abdelnaser

    2015-07-01

    Spirometry is the most commonly used method for assessment of airway function in bronchial asthma but has several limitations. Forced oscillometry was developed as a patient-friendly test that requires passive cooperation of the patient breathing normally through the mouth. To compare spirometry with forced oscillometry to assess the role of forced oscillometry in the detection of the site of airway obstruction. This case-and-control study included 50 patients with known stable asthma and 50 age- and sex-matched healthy subjects. All participants underwent spirometry (ratio of force expiration volume in 1 second to forced vital capacity, percentage predicted for forced expiration volume in 1 second, percentage predicted for forced vital capacity, percentage predicted for vital capacity, and forced expiratory flow at 25-75%) and forced oscillometry (resistance at 5, 20, and 5-20 Hz). By spirometry, all patients with asthma had airway obstruction, 8% had isolated small airway obstruction, 10% had isolated large airway obstruction, and 82% had large and small airway obstruction. By forced oscillometry, 12% had normal airway resistance, 50% had isolated small airway obstruction with frequency-dependent resistance, and 38% had large and small airway obstruction with frequency-independent resistance. There was significant difference between techniques for the detection of the site of airway obstruction (P = .012). Forced oscillometry indices were negatively correlated with spirometric indices (P < .01). Forced oscillometry as an effortless test, conducted during quiet tidal breathing, and does not alter airway caliber; thus, it can detect normal airway function better than spirometry in patients with asthma. Forced oscillometry detects isolated small airway obstruction better than spirometry in bronchial asthma. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  12. A Fluorescence Quenching Assay Based on Molecular Beacon Formation through a Ligase Detection Reaction for Facile and Rapid Detection of Point Mutations.

    PubMed

    Sawamura, Kensuke; Hashimoto, Masahiko

    2017-01-01

    A fluorescence quenching assay based on a ligase detection reaction was developed for facile and rapid detection of point mutations present in a mixed population of non-variant DNA. If the test DNA carried a targeted mutation, then the two allele-specific primers were ligated to form a molecular beacon resulting in the expected fluorescence quenching signatures. Using this method, we successfully detected as low as 5% mutant DNA in a mixture of wild-type DNA (t test at 99% confidence level).

  13. Molecular beacon anchored onto a graphene oxide substrate

    NASA Astrophysics Data System (ADS)

    Darbandi, Arash; Datta, Debopam; Patel, Krunal; Lin, Gary; Stroscio, Michael A.; Dutta, Mitra

    2017-09-01

    In this article, we report a graphene oxide-based nanosensor incorporating semiconductor quantum dots linked to DNA-aptamers that functions as a ‘turn-off’ fluorescent nanosensor for detection of low concentrations of analytes. A specific demonstration of this turn-off aptasensor is presented for the case of the detection of mercury (II) ions. In this system, ensembles of aptamer-based quantum-dot sensors are anchored onto graphene oxide (GO) flakes which provide a platform for analyte detection in the vicinity of GO. Herein, the operation of this ensemble-based nanosensor is demonstrated for mercury ions, which upon addition of mercury, quenching of the emission intensity from the quantum dots is observed due to resonance energy transfer between quantum dots and the gold nanoparticle connected via a mercury target aptamer. A key result is that the usually dominant effect of quenching of the quantum dot due to close proximity to the GO can be reduced to negligible levels by using a linker molecule in conjunctions with the aptamer-based nanosensor. The effect of ionic concentration of the background matrix on the emission intensity was also investigated. The sensor system is found to be highly selective towards mercury and exhibits a linear behavior (r 2 > 0.99) in the nanomolar concentration range. The detection limit of the sensor towards mercury with no GO present was found to be 16.5 nM. With GO attached to molecular beacon via 14 base, 35 base, and 51 base long linker DNA, the detection limit was found to be 38.4 nM, 9.45 nM, and 11.38 nM; respectively.

  14. Study of flight data recorder, underwater locator beacon, data logger and flarm collision avoidance system

    NASA Astrophysics Data System (ADS)

    Timi, Purnota Hannan; Shermin, Saima; Rahman, Asifur

    2017-06-01

    Flight data recorder is one of the most important sources of flight data in event of aviation disaster which records a wide range of flight parameters including altitude, airspeed, heading etc. and also helps monitoring and analyzing aircraft performance. Cockpit voice recorder records radio microphone transmissions and sounds in the cockpit. These devices help to find out and understand the root causes of aircraft crashes and help building better aircraft systems and technical solutions to prevent similar type of crashes in future, which lead to improvement in safety of aircrafts and passengers. There are other devices also which enhance the aircraft safety and assists in emergency or catastrophic situations. This paper discusses the concept of Flight Data Recorder (FDR), Cockpit Voice Recorder (CVR), Underwater Locator Beacon (ULB), Data logger and flarm-collision avoidance system for aircraft and their applications in aviation.

  15. Bowel obstruction: Differential diagnosis and clinical management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, J.P.

    1987-01-01

    This book presents a practical guide to the diagnosis and management of obstruction, both mechanical and organic, of the large and small bowel. Obstruction is a common problem for surgeons, and this text emphasizes differential diagnosis and the use of all radiologic modalities. It presents the surgical and medical considerations involved with gallstones, bezoars, parasites, tumors, inflammation, trauma, intussusception, more.

  16. Giant colonic volvulus due to colonic pseudo-obstruction

    PubMed Central

    Karaman, Kerem; Tanoglu, Alpaslan; Beyazit, Yavuz; Han, Ismet

    2015-01-01

    Acute colonic pseudo-obstruction (ACPO), also known as Ogilvie’s syndrome, is a clinical syndrome characterised by gross dilation of the caecum and right hemicolon, which sometimes extends to the sigmoid colon and rectum in the absence of an anatomic lesion in the intestinal lumen. It is characterised by impaired propulsion of contents of the gastrointestinal tract, which results in a clinical picture of intestinal obstruction. A careful examination of the markedly distended colon can exclude several colonic pathologies, including mechanical obstruction and other causes of toxic megacolon. ACPO can sometimes predispose or mimic colonic volvulus, especially in geriatric patients. PMID:25716038

  17. A Case of Polyarteritis Nodosa with Bilateral Ureteral Obstruction

    PubMed Central

    Yoo, Bin; Kim, Hong Kyu; Choi, Seung Won; Moon, Hee Bom

    1996-01-01

    We report a case of bilateral ureteral obstruction most likely caused by polyarteritis nodosa. The diagnosis was based upon muscle biopsy which showed typical necrotizing vasculitis in medium size artery in conjunction with microaneurysms in renal angiography. Ureteral obstruction is a rare manifestation of polyarteritis nodosa. This condition is thought to result from vasculitis of periureteral vessels. The patient was managed with prednisolone alone, which resulted in complete resolution of ureteral obstruction on both sides. PMID:8854655

  18. Airway Obstruction Among Latino Poultry Processing Workers in North Carolina

    PubMed Central

    MIRABELLI, MARIA C.; CHATTERJEE, ARJUN B.; MORA, DANA C.; ARCURY, THOMAS A.; BLOCKER, JILL N.; CHEN, HAIYING; GRZYWACZ, JOSEPH G.; MARÍN, ANTONIO J.; SCHULZ, MARK R.; QUANDT, SARA A.

    2015-01-01

    This analysis was conducted to evaluate the prevalence of airway obstruction among Latino poultry processing workers. Data were collected from 279 poultry processing workers and 222 other manual laborers via spirometry and interviewer-administered questionnaires. Participants employed in poultry processing reported the activities they perform at work. Participants with forced expiratory volume in 1 second (FEV1) or FEV1/forced expiratory volume (FVC) below the lower limits of normal were categorized as having airway obstruction. Airway obstruction was identified in 13% of poultry processing workers and 12% of the comparison population. Among poultry processing workers, the highest prevalence of airway obstruction (21%) occurred among workers deboning chickens (prevalence ratio: 1.75; 95% confidence interval: 0.97, 3.15). These findings identify variations in the prevalence of airway obstruction across categories of work activities. PMID:24965321

  19. Chronic Obstructive Pulmonary Disease: Diagnosis and Management.

    PubMed

    Gentry, Shari; Gentry, Barry

    2017-04-01

    The diagnosis of chronic obstructive pulmonary disease (COPD) should be suspected in patients with risk factors (primarily a history of smoking) who report dyspnea at rest or with exertion, chronic cough with or without sputum production, or a history of wheezing. COPD may be suspected based on findings from the history and physical examination, but must be confirmed by spirometry to detect airflow obstruction. Findings that are most helpful to rule in COPD include a smoking history of more than 40 pack-years, a self-reported history of COPD, maximal laryngeal height, and age older than 45 years. The combination of three clinical variables-peak flow rate less than 350 L per minute, diminished breath sounds, and a smoking history of 30 pack-years or more-is another good clinical predictor, whereas the absence of all three of these signs essentially rules out airflow obstruction. Pharmacotherapy and smoking cessation are the mainstays of treatment, and pulmonary rehabilitation, long-term oxygen therapy, and surgery may be considered in select patients. Current guidelines recommend starting monotherapy with an inhaled bronchodilator, stepping up to combination therapy as needed, and/or adding inhaled corticosteroids as symptom severity and airflow obstruction progress.

  20. Probing of congenital nasolacrimal duct obstruction with dacryoendoscope

    PubMed Central

    Kato, Kumiko; Matsunaga, Koichi; Takashima, Yuko; Kondo, Mineo

    2014-01-01

    Background A congenital nasolacrimal duct obstruction (CNLDO) is a relatively common disease in infants. We evaluated the results of probing three patients with CNLDO, under direct view, with a dacryoendoscope. Methods Three cases of CNLDO were examined and treated by probing with a dacryoendoscope, under intravenous anesthesia. The diameter of the dacryoendoscope probe was 0.7 mm, and we were able to observe the inner walls of the lacrimal duct and able to guide the probe through the duct. Results In all cases, the site of obstruction was detected, and the probe was used to remove the obstruction. At 2 weeks after the removal of the obstruction, there was no epiphora or mucopurulent discharge in any of the cases. No complications were detected intra- and postoperatively. Conclusion Although only three cases were studied, we believe that probing with a dacryoendoscope is a safe and effective method of treating a CNLDO. More cases need to be studied. PMID:24876765

  1. How a Beacon Community Program in New Orleans Helped Create a Better Health Care System by Building Relationships before Technology.

    PubMed

    Khurshid, Anjum; Brown, Lisanne

    2014-01-01

    In the aftermath of Hurricane Katrina, much of New Orleans' healthcare infrastructure was destroyed. Initial federal funding after the storm expanded primary care services and helped set up medical homes for New Orleans' large uninsured and underinsured population. Following that, the Beacon Community in New Orleans, charged with improving health care through the use of technology, decided the best way to accomplish those goals was to build community partnerships and introduce technology improvements based on their input and on their terms. The purpose of this paper is to describe how those partnerships were wrought, including the innovative use of a conceptual framework, and how they are being sustained; how different technologies were and are being introduced; and what the results have been so far. Past successful community experiences, as well as a proven conceptual framework, were used to help establish community partnerships and governance structures, as well as to demonstrate their linkages. This paper represents a compilation of reports and information from key Beacon leaders, staff and providers and their firsthand experiences in setting up those structures, as well as their conclusions. The community partnerships proved extremely successful in not only devising successful ways to introduce new technology into healthcare settings, but in sustaining those changes by creating a governance structure that has enough fluidity to adapt to changing circumstances. Building and developing community partnerships takes time and effort; however, these relationships are necessary and essential to introducing and sustaining new technologies in a healthcare setting and should be a first step for any organization looking to accomplish such goals.

  2. A Computational Study of the Respiratory Airflow Characteristics in Normal and Obstructed Human Airways

    DTIC Science & Technology

    2014-01-01

    normal and three different obstructed airway geometries, consisting of symmetric, asym- metric, and random obstructions. Fig. 2 shows the geometric ...normal and obstructed airways Airway resistance is a measure of the opposition to the airflow caused by geometric properties, such as airway obstruction...pressure drops. Resistance values were dependent on the degree and geometric distribution of the obstruction sites. In the symmetric obstruction model

  3. Caecal volvulus in a patient with chronic intestinal pseudo-obstruction

    PubMed Central

    El-Khatib, C

    2011-01-01

    Chronic intestinal pseudo-obstruction (CIPO) is a rare disorder characterised by recurrent symptoms and signs of intestinal obstruction without an underlying mechanical cause. Caecal volvulus remains a rare cause of intestinal obstruction that often requires operative intervention. We describe the previously unreported case of caecal volvulus occurring in an adult patient with CIPO, together with his subsequent management. PMID:22004621

  4. First results from the ionospheric tomography experiment using beacon TEC data obtained by means of a network along a longitude of 136°E over Japan

    NASA Astrophysics Data System (ADS)

    Thampi, Smitha V.; Yamamoto, Mamoru

    2010-03-01

    A chain of newly designed GNU (GNU is not UNIX) Radio Beacon Receivers (GRBR) has recently been established over Japan, primarily for tomographic imaging of the ionosphere over this region. Receivers installed at Shionomisaki (33.45°N, 135.8°E), Shigaraki (34.8°N, 136.1°E), and Fukui (36°N, 136°E) continuously track low earth orbiting satellites (LEOS), mainly OSCAR, Cosmos, and FORMOSAT-3/COSMIC, to obtain simultaneous total electron content (TEC) data from these three locations, which are then used for the tomographic reconstruction of ionospheric electron densities. This is the first GRBR network established for TEC observations, and the first beacon-based tomographic imaging in Japanese longitudes. The first tomographic images revealed the temporal evolution with all of the major features in the ionospheric electron density distribution over Japan. A comparison of the tomographically reconstructed electron densities with the ƒ o F 2 data from Kokubunji (35°N, 139°E) revealed that there was good agreement between the datasets. These first results show the potential of GRBR and its network for making continuous, unattended ionospheric TEC measurements and for tomographic imaging of the ionosphere.

  5. Murine model of long term obstructive jaundice

    PubMed Central

    Aoki, Hiroaki; Aoki, Masayo; Yang, Jing; Katsuta, Eriko; Mukhopadhyay, Partha; Ramanathan, Rajesh; Woelfel, Ingrid A.; Wang, Xuan; Spiegel, Sarah; Zhou, Huiping; Takabe, Kazuaki

    2016-01-01

    Background With the recent emergence of conjugated bile acids as signaling molecules in cancer, a murine model of obstructive jaundice by cholestasis with long-term survival is in need. Here, we investigated the characteristics of 3 murine models of obstructive jaundice. Methods C57BL/6J mice were used for total ligation of the common bile duct (tCL), partial common bile duct ligation (pCL), and ligation of left and median hepatic bile duct with gallbladder removal (LMHL) models. Survival was assessed by Kaplan-Meier method. Fibrotic change was determined by Masson-Trichrome staining and Collagen expression. Results 70% (7/10) of tCL mice died by Day 7, whereas majority 67% (10/15) of pCL mice survived with loss of jaundice. 19% (3/16) of LMHL mice died; however, jaundice continued beyond Day 14, with survival of more than a month. Compensatory enlargement of the right lobe was observed in both pCL and LMHL models. The pCL model demonstrated acute inflammation due to obstructive jaundice 3 days after ligation but jaundice rapidly decreased by Day 7. The LHML group developed portal hypertension as well as severe fibrosis by Day 14 in addition to prolonged jaundice. Conclusion The standard tCL model is too unstable with high mortality for long-term studies. pCL may be an appropriate model for acute inflammation with obstructive jaundice but long term survivors are no longer jaundiced. The LHML model was identified to be the most feasible model to study the effect of long-term obstructive jaundice. PMID:27916350

  6. Obstructive sleep apnea due to extrathoracic tracheomalacia.

    PubMed

    Muzumdar, Hiren; Nandalike, K; Bent, J; Arens, Raanan

    2013-02-01

    We report obstructive sleep apnea in a 3-year-old boy with tracheomalacia secondary to tracheotomy that resolved after placement of a metallic stent in the region of tracheomalacia. The tracheal location of obstruction during sleep in this case contrasts with the usual location in the pharynx or, less often, the larynx. This case also demonstrates the utility of polysomnography in managing decannulation of tracheostomies.

  7. Congenital ureteropelvic junction obstruction: physiopathology, decoupling of tout court pelvic dilatation-obstruction semantic connection, biomarkers to predict renal damage evolution.

    PubMed

    Alberti, C

    2012-02-01

    The widespread use of fetal ultrasonography results in a frequent antenatally observation of hydronephrosis, ureteropelvic junction obstruction (UPJO) accounting for the greatest fraction of congenital obstructive nephropathy. UPJO may be considered, in most cases, as a functional obstructive condition, depending on defective fetal smooth muscle/nerve development at this level, with lack of peristaltic wave propagation--aperistaltic segment--and, therefore, poor urine ejection from the renal pelvis into the ureter. The UPJO-related physiopathologic events are, at first, the compliant dilatation of renal pelvis that, acting as hydraulic buffer, protects the renal parenchyma from the rising intrapelvic pressure-related potential damages, and, subsequently, beyond such phase of dynamic balance, the tubular cell stretch-stress induced by increased intratubular pressure and following parenchymal inflammatory lesions: inflammatory infiltrates, fibroblast proliferation, activation of myofibroblasts, tubulo-interstitial fibrosis. Reactive oxygen species (ROS), nitric oxide (NO), several chemo- and cytokines, growth factors, prostaglandins and eicosanoids, angiotensin-II are the main pathogenetic mediators of the obstructive nephropathy. Apoptosis of tubular cells is the major cause of the tubular atrophy, together with epithelial-mesenchymal transdifferentiation. Some criticisms on tout court semantic renal pelvis dilatation-obstruction connection have been raised considering that the renal pelvis expansion isn't, in any case, linked to an ostructive condition, as it may be verified by diuretic (furosemide) renogram together with scintiscan-based evaluation of differential renal function. In this regard, rather than repetitive invasive nuclear procedures that expose the children to ionizing radiations, an intriguing noninvasive strategy, based on the evaluation of urinary biomarkers and urinary proteome, can define the UPJO-related possible progress of parenchymal lesions

  8. The Contribution of Small Airway Obstruction to the Pathogenesis of Chronic Obstructive Pulmonary Disease.

    PubMed

    Hogg, James C; Paré, Peter D; Hackett, Tillie-Louise

    2017-04-01

    The hypothesis that the small conducting airways were the major site of obstruction to airflow in normal lungs was introduced by Rohrer in 1915 and prevailed until Weibel introduced a quantitative method of studying lung anatomy in 1963. Green repeated Rohrer's calculations using Weibels new data in 1965 and found that the smaller conducting airways offered very little resistance to airflow. This conflict was resolved by seminal experiments conducted by Macklem and Mead in 1967, which confirmed that a small proportion of the total lower airways resistance is attributable to small airways <2 mm in diameter. Shortly thereafter, Hogg, Macklem, and Thurlbeck used this technique to show that small airways become the major site of obstruction in lungs affected by emphysema. These and other observations led Mead to write a seminal editorial in 1970 that postulated the small airways are a silent zone within normal lungs where disease can accumulate over many years without being noticed. This review provides a progress report since the 1970s on methods for detecting chronic obstructive pulmonary disease, the structural nature of small airways' disease, and the cellular and molecular mechanisms that are thought to underlie its pathogenesis. Copyright © 2017 the American Physiological Society.

  9. Exposure to PM10 as a risk factor for the development of nasal obstruction and chronic obstructive pulmonary disease

    PubMed Central

    Sichletidis, Lazaros; Spyratos, Dionisios; Tsiotsios, Anastasios; Haidich, Anna-Bettina; Chloros, Diamantis; Ganidis, Ioannis; Michailidis, Dimitrios; Triantafyllou, Georgios; Kottakis, George; Melas, Dimitrios

    2014-01-01

    Objectives: To investigate whether air pollution is a potential risk factor for airways obstruction. Methods: A prospective cohort study (11.3±2.9 years) that took place in two areas (Eordea where concentration of PM10 was high and Grevena, Greece). We used the MRC questionnaire, spirometry, and anterior rhinomanometry at both visits. Results: Initially we examined 3046 subjects. After excluding chronic obstructive pulmonary disease (COPD) patients, we re-examined 872 subjects and 168 of them had developed COPD (Grevena: 24.3%, Eordea: 18.5%). Multivariable logistic regression analysis showed that the area of residence and thus exposure to air pollution was not a risk factor for the development of COPD (OR: 0.51, 95% CI: 0.18–1.46, P = 0.21). On the other hand, residence in Eordea was strongly related to the development of severe nasal obstruction (OR: 11.47, 95% CI: 6.15–21.40, P<0.001). Similar results were found after excluding patients with COPD stage I as well as in the subgroup of never smokers. Conclusion: Air pollution was associated with severe nasal obstruction but not with COPD development. PMID:24804336

  10. Molecular beacon-enabled purification of living cells by targeting cell type-specific mRNAs.

    PubMed

    Wile, Brian M; Ban, Kiwon; Yoon, Young-Sup; Bao, Gang

    2014-10-01

    Molecular beacons (MBs) are dual-labeled oligonucleotides that fluoresce only in the presence of complementary mRNA. The use of MBs to target specific mRNAs allows sorting of specific cells from a mixed cell population. In contrast to existing approaches that are limited by available surface markers or selectable metabolic characteristics, the MB-based method enables the isolation of a wide variety of cells. For example, the ability to purify specific cell types derived from pluripotent stem cells (PSCs) is important for basic research and therapeutics. In addition to providing a general protocol for MB design, validation and nucleofection into cells, we describe how to isolate a specific cell population from differentiating PSCs. By using this protocol, we have successfully isolated cardiomyocytes differentiated from mouse or human PSCs (hPSCs) with ∼ 97% purity, as confirmed by electrophysiology and immunocytochemistry. After designing MBs, their ordering and validation requires 2 weeks, and the isolation process requires 3 h.

  11. Entropy Beacon: A Hairpin-Free DNA Amplification Strategy for Efficient Detection of Nucleic Acids

    PubMed Central

    2015-01-01

    Here, we propose an efficient strategy for enzyme- and hairpin-free nucleic acid detection called an entropy beacon (abbreviated as Ebeacon). Different from previously reported DNA hybridization/displacement-based strategies, Ebeacon is driven forward by increases in the entropy of the system, instead of free energy released from new base-pair formation. Ebeacon shows high sensitivity, with a detection limit of 5 pM target DNA in buffer and 50 pM in cellular homogenate. Ebeacon also benefits from the hairpin-free amplification strategy and zero-background, excellent thermostability from 20 °C to 50 °C, as well as good resistance to complex environments. In particular, based on the huge difference between the breathing rate of a single base pair and two adjacent base pairs, Ebeacon also shows high selectivity toward base mutations, such as substitution, insertion, and deletion and, therefore, is an efficient nucleic acid detection method, comparable to most reported enzyme-free strategies. PMID:26505212

  12. Detection of bacterial 16S rRNA using a molecular beacon-based X sensor

    PubMed Central

    Gerasimova, Yulia V.; Kolpashchikov, Dmitry M.

    2012-01-01

    We demonstrate how a long structurally constrained RNA can be analyzed in homogeneous solution at ambient temperatures with high specificity using a sophisticated biosensor. The sensor consists of a molecular beacon probe as a signal reporter and two DNA adaptor strands, which have fragments complementary to the reporter and to the analyzed RNA. One adaptor strand uses its long RNA-binding arm to unwind the RNA secondary structure. Second adaptor strand with a short RNA-binding arm hybridizes only to a fully complementary site, thus providing high recognition specificity. Overall the three-component sensor and the target RNA form a four-stranded DNA crossover (X) structure. Using this sensor, E.coli 16S rRNA was detected in real time with the detection limit of ~ 0.17 nM. The high specificity of the analysis was proven by differentiating B.subtilus from E.coli 16S rRNA sequences. The sensor responds to the presence of the analyte within seconds. PMID:23021850

  13. Using the Pathophysiology of Obstructive Sleep Apnea to Teach Cardiopulmonary Integration

    ERIC Educational Resources Information Center

    Levitzky, Michael G.

    2008-01-01

    Obstructive sleep apnea (OSA) is a common disorder of upper airway obstruction during sleep. The effects of intermittent upper airway obstruction include alveolar hypoventilation, altered arterial blood gases and acid-base status, and stimulation of the arterial chemoreceptors, which leads to frequent arousals. These arousals disturb sleep…

  14. Airway obstruction in children with infectious mononucleosis.

    PubMed

    Wohl, D L; Isaacson, J E

    1995-09-01

    Epstein-Barr Virus (EBV) infection generally has a benign clinical course. Upper airway obstruction is a known complication requiring the otolaryngologist's attention. EBV is usually associated with adolescence but has been increasingly documented in younger children. We review 36 pediatric admissions for infectious mononucleosis over a 12-year period at our institution, 11 of which required consultation for airway obstruction. Airway management was based on clinical severity and ranged from monitored observation, with or without nasopharyngeal stenting, to prolonged intubation or emergent tonsilloadenoidectomy. A rare case of a four-year-old with near total upper airway obstruction secondary to panpharyngeal and transglottic inflammatory edema prompted this review and is reported. The otolaryngologist must recognize the potential severity of EBV-related airway compromise and be prepared to manage it.

  15. Space Weather Operation at KASI With Van Allen Probes Beacon Signals

    NASA Astrophysics Data System (ADS)

    Lee, Jongkil; Kim, Kyung-Chan; Giuseppe, Romeo; Ukhorskiy, Sasha; Sibeck, David; Kessel, Ramona; Mauk, Barry; Giles, Barbara; Gu, Bon-Jun; Lee, Hyesook; Park, Young-Deuk; Lee, Jaejin

    2018-02-01

    The Van Allen Probes (VAPs) are the only modern National Aeronautics and Space Administration (NASA) spacecraft broadcasting real-time data on the Earth's radiation belts for space weather operations. Since 2012, the Korea Astronomy and Space Science Institute (KASI) has contributed to the receipt of these data via a 7 m satellite-tracking antenna and used these beacon data for space weather operations. An approximately 15 min period is required from measurement to acquisition of Level-1 data. In this paper, we demonstrate the use of VAP data for monitoring space weather conditions at geostationary orbit (GEO) by highlighting the Saint Patrick's Day storm of 2015. During that storm, Probe-A observed a significant increase in the relativistic electron flux at 3 RE. Those electrons diffused outward resulting in a large increase of the electron flux >2 MeV at GEO, which potentially threatened satellite operations. Based on this study, we conclude that the combination of VAP data and National Oceanic and Atmospheric Administration-Geostationary Operational Environmental Satellite (NOAA-GOES) data can provide improved space environment information to geostationary satellite operators. In addition, the findings obtained indicate that more data-receiving sites would be necessary and data connections improved if this or a similar system were to be used as an operational data service.

  16. Obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma.

    PubMed

    Balbay, Ege G; Balbay, Oner; Annakkaya, Ali N; Suner, Kezban O; Yuksel, Harun; Tunç, Murat; Arbak, Peri

    2014-10-01

    To investigate the prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma. Case series. School of Medicine, Düzce University, Turkey. Twenty-one consecutive primary open-angle glaucoma patients (12 females and 9 males) who attended the out-patient clinic of the Department of Ophthalmology between July 2007 and February 2008 were included in this study. All patients underwent polysomnographic examination. The prevalence of obstructive sleep apnoea syndrome was 33.3% in patients with primary open-angle glaucoma; the severity of the condition was mild in 14.3% and moderate in 19.0% of the subjects. The age (P=0.047) and neck circumference (P=0.024) in patients with obstructive sleep apnoea syndrome were significantly greater than those without the syndrome. Triceps skinfold thickness in glaucomatous obstructive sleep apnoea syndrome patients reached near significance versus those without the syndrome (P=0.078). Snoring was observed in all glaucoma cases with obstructive sleep apnoea syndrome. The intra-ocular pressure of patients with primary open-angle glaucoma with obstructive sleep apnoea syndrome was significantly lower than those without obstructive sleep apnoea syndrome (P=0.006 and P=0.035 for the right and left eyes, respectively). There was no significant difference in the cup/disc ratio and visual acuity, except visual field defect, between primary open-angle glaucoma patients with and without obstructive sleep apnoea syndrome. Although it does not provide evidence for a cause-effect relationship, high prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma in this study suggests the need to explore the long-term results of coincidence, relationship, and cross-interaction of these two common disorders.

  17. Hypertension, Snoring, and Obstructive Sleep Apnea During Pregnancy: A Cohort Study

    PubMed Central

    O’Brien, Louise M.; Bullough, Alexandra S.; Chames, Mark C.; Shelgikar, Anita V.; Armitage, Roseanne; Guilleminualt, Christian; Sullivan, Colin E.; Johnson, Timothy R. B.; Chervin, Ronald D.

    2014-01-01

    Objective To assess the frequency of obstructive sleep apnea among women with and without hypertensive disorders of pregnancy. Design Cohort study. Setting Obstetric clinics at an academic medical center. Population Pregnant women with hypertensive disorders (chronic hypertension, gestational hypertension, or pre-eclampsia) and normotensive women. Methods Women completed a questionnaire about habitual snoring and underwent overnight ambulatory polysomnography. Main Outcome Measures The presence and severity of obstructive sleep apnea. Results Obstructive sleep apnoea was found among 21 of 51 women with hypertensive disorders (41%), but in only three of 16 women who were normotensive (19%, chi-square test, P = 0.005). Non-snoring hypertensive women typically had mild obstructive sleep apnea but >25% of snoring hypertensive women had moderate-to-severe obstructive sleep apnea. Among the hypertensive women, the mean apnea/hypopnea index was substantially higher in snorers than non-snorers (19.9±34.1 vs. 3.4±3.1, p=0.013) and the oxyhemoglobin saturation nadir was significantly lower (86.4±6.6 vs. 90.2±3.5, p=0.021). Among hypertensive women, after stratification by obesity the pooled relative risk for obstructive sleep apnea in snoring women with hypertension compared to non-snoring hypertension was 2.0 [95%CI 1.4–2.8]. Conclusions Pregnant women with hypertension are at high risk for unrecognised obstructive sleep apnea. While longitudinal and intervention studies are urgently needed, it would seem pertinent given the known relationship between obstructive sleep apnea and hypertension in the general population, that hypertensive pregnant women who snore should be tested for obstructive sleep apnea, a condition believed to cause or promote hypertension. PMID:24888772

  18. Design of multi-modal obstruction to control tonal fan noise using modulation principles

    NASA Astrophysics Data System (ADS)

    Gérard, Anthony; Moreau, Stéphane; Berry, Alain; Masson, Patrice

    2015-11-01

    The approach presented in this paper uses a combination of obstructions in the upstream flow of subsonic axial fans with B blades to destructively interfere with the primary tonal noise at the blade passage frequency. The first step of the proposed experimental method consists in identifying the independent radiation of B - 1 and B lobed obstructions at the control microphones. During this identification step, rotating obstructions allow for the frequencies of primary and secondary tonal noise to be slightly shifted in the spectrum due to modulation principles. The magnitude of the secondary tonal noise generated by each obstruction can be adjusted by varying the size of the lobes of the obstruction, and the phase of the secondary tonal noise is related to the angular position of the obstruction. The control obstructions are then optimized by combining the B - 1 and B lobed obstructions to significantly reduce the acoustic power at blade passage frequency.

  19. Diversity reception of COMSTAR SHF beacons with the Tampa triad, 1978 - 1981

    NASA Technical Reports Server (NTRS)

    Davidson, D.; Tang, D. D.

    1982-01-01

    The results of 19 GHz downlink rain attenuation diversity measurements in Tampa over a 29 month period (1978-1980), and the results of a 20 GHz diversity study during the summer of 1981, using the remaining COMSTAR beacon are presented. At 19 GHz, site separations of 11, 16, and 20 km were used, with reception at high elevation angle (about 57 deg). At 29 GHz, only the 16 km baseline was employed, with elevation angle about 32 deg. Almost identical long term performance of the two longer baselines indicates that for separations above about 15 km diversity improvement was not sensitive to baseline length or direction. Diversity improvement at 29 GHz with the 16 km baseline was similar to that predicted by scaling the 19 GHz results of the previous seasons. Also discussed are the type of attenuation distributions and typical fade durations to be found under persistent convective conditions. For rain climates like Tampa's, site diversity in some form will be required for high reliability SHF satellite links. The diversity data may be helpful in designing schemes for resource sharing among numbers of links.

  20. Utility of CT in the diagnosis and management of small-bowel obstruction in children.

    PubMed

    Wang, Qiuyan; Chavhan, Govind B; Babyn, Paul S; Tomlinson, George; Langer, Jacob C

    2012-12-01

    CT is often used in the diagnosis and management of small-bowel obstruction in children. To determine sensitivity of CT in delineating presence, site and cause of small-bowel obstruction in children. We retrospectively reviewed the CT scans of 47 children with surgically proven small-bowel obstruction. We noted any findings of obstruction and the site and cause of obstruction. Presence, absence or equivocal findings of bowel obstruction on abdominal radiographs performed prior to CT were also noted. We reviewed patient charts for clinical details and surgical findings, including bowel resection. Statistical analysis was performed using Fisher exact test to determine which CT findings might predict bowel resection. CT correctly diagnosed small-bowel obstruction in 43/47 (91.5%) cases. CT correctly indicated site of obstruction in 37/47 (78.7%) cases and cause of obstruction in 32/47 (68.1%) cases. Small-bowel feces sign was significantly associated with bowel resection at surgery (P = 0.0091). No other CT finding was predictive of bowel resection. Out of 41 children who had abdominal radiographs before CT, 29 (70.7%) showed unequivocal obstruction, six (14.6%) showed equivocal findings and six (14.6%) were unremarkable. CT is highly sensitive in diagnosing small-bowel obstruction in children and is helpful in determining the presence of small-bowel obstruction in many clinically suspected cases with equivocal or normal plain radiographs. CT also helps to determine the site and cause of the obstruction with good sensitivity.

  1. Eucapnic voluntary hyperventilation in diagnosing exercise-induced laryngeal obstructions.

    PubMed

    Christensen, Pernille M; Rasmussen, Niels

    2013-11-01

    Exercise-induced laryngeal obstructions (EILOs) cause exercise-related respiratory symptoms (ERRS) and are important differential diagnoses to exercise-induced asthma. The diagnostic method for EILOs includes provocation to induce the obstruction followed by a verification of the obstruction and the degree thereof. The objective of the present study was to examine if a eucapnic voluntary hyperventilation (EVH) test could induce laryngeal obstructions laryngoscopically identical in subtypes and development as seen during an exercise test. EVH and exercise testing with continuous laryngoscopy were performed during a screening of two national athletic teams (n = 67). The laryngoscopic recordings were examined for usability, abnormalities and maximal supraglottic and glottic obstruction using two currently available methods (Eilomea and CLE-score). The participants were asked questions on ERRS, and whether the symptoms experienced during each provocation matched those experienced during regular training. A total of 39 completed both tests. There were no significant differences in subtypes and development thereof, the experience of symptoms, and specificity and sensitivity between the methods. Significantly more recordings obtained during the exercise test were usable for evaluation primarily due to resilient mucus on the tip of the fiber-laryngoscope in the EVH test. Only recordings of six athletes from both provocation methods were usable for evaluation using the Eilomea method (high-quality demand). Amongst these, a linear correlation was found for the glottic obstruction. EVH tests can induce EILOs. However, the present test protocol needs adjustments to secure better visualisation of the larynx during provocation.

  2. [Severe upper airway obstruction in infectious mononucleosis: a life emergency].

    PubMed

    Salazard, B; Paut, O; Nicollas, R; Zandotti, C; Chrestian, M A; Thuret, I; Camboulives, J

    2001-09-01

    Upper airway obstruction can represent a severe, life-threatening complication of infectious mononucleosis. We report a rare case of airway obstruction in a child with infectious mononucleosis associated with herpes virus infection, and we discuss management strategy that can be proposed in such cases. A 9-year-old girl was hospitalised in intensive care unit for obstructive dyspnea during infectious mononucleosis. Despite five days of corticosteroids and tracheal intubation, persistent pharyngo-tonsillar tumefaction led us to perform a surgical adenotonsillectomy. This latter treatment allowed immediate tracheal extubation and a rapid recovery. Histology showed a herpes virus infection associated with infectious mononucleosis. Maintaining airway opening in infectious mononucleosis needs sometimes to use instrumental interventions: nasal trumpet, endotracheal intubation, even tracheostomy. Early tonsilloadenoidectomy may relieve airway obstruction and allow a rapid recovery in the most severe cases. Airway obstruction in infectious mononucleosis may be aggravated by concomitant herpes virus infection that should be searched for in this situation, in order to adapt the treatment.

  3. Paediatric obstructive sleep apnoea: is our operative management evidence-based?

    PubMed

    Pabla, L; Duffin, J; Flood, L; Blackmore, K

    2018-04-01

    Despite the plethora of publications on the subject of paediatric obstructive sleep apnoea, there seems to be wide variability in the literature and in practice, regarding recourse to surgery, the operation chosen, the benefits gained and post-operative management. This may reflect a lack of high-level evidence. A systematic review of four significant controversies in paediatric ENT was conducted from the available literature: tonsillectomy versus tonsillotomy, focusing on the evidence base for each; anaesthetic considerations in paediatric obstructive sleep apnoea surgery; the objective evidence for the benefits of surgical treatment for obstructive sleep apnoea; and the medical treatment options for residual obstructive sleep apnoea after surgical treatment. There are many gaps in the evidence base for the surgical correction of obstructive sleep apnoea. There is emerging evidence favouring subtotal tonsillectomy. There is continuing uncertainty around the prediction of the level of post-operative care that any individual child might require. The long-term benefit of surgical correction is a particularly fertile ground for further research.

  4. Endoscopic Stent Placement in the Palliation of Malignant Biliary Obstruction

    PubMed Central

    2011-01-01

    Biliary drainage with biliary stent placement is the treatment of choice for palliation in patients with malignant biliary obstruction caused by unresectable neoplasms. In such patients, the endoscopic approach can be initially used with percutaneous radiological intervention. In patients with unresectable malignant distal bile duct obstructions, endoscopic biliary drainage with biliary stent placement has now become the main and least invasive palliative modality, which has been proven to be more effective in >80% of cases with lower morbidity than surgery, and perhaps may provide a survival benefit. In patients with unresectable malignant hilar obstruction, the endoscopic approach for biliary drainage with biliary stent placement has also been considered as the treatment of choice. There is still a lack of clear consensus on the use of covered versus uncovered metal stents in malignant distal bile duct obstructions and plastic versus metal stents and unilateral versus bilateral drainage in malignant hilar obstructions. PMID:22741117

  5. ''Sandwich'' treatment for diospyrobezoar intestinal obstruction: A case report

    PubMed Central

    Zheng, Yi-Xiong; Prasoon, Pankaj; Chen, Yan; Hu, Liang; Chen, Li

    2014-01-01

    Intestinal obstruction is a common clinical entity encountered in surgical practice. The objective of this report is to corroborate an atypical scenario of intestinal obstruction in a Chinese patient and to focus on the diagnosis and treatment. A 27-year-old male presented with a history of gastric pain combined with nausea and abdominal distension that had been present for 5 d. The presence of a foreign body was detected by computed tomography and observed as an abnormal density within the stomach. A diospyrobezoar was revealed during gastroscopy, the extraction of which was prevented due to its size and firmness. An endoscopic holmium laser joined with a snare was used to fragment the obstruction, which was followed by management with a conservative “sandwich” treatment strategy involving intestinal decompression with an ileus tube and Coca-Cola lavage between endoscopic lithotripsy fragmentation procedures. This strategy resulted in the successful removal of the diospyrobezoar along with multiple small bowel obstructions. The patient was discharged after abatement of symptoms. The case presented here demonstrates the implementation of a conservative, yet successful, treatment as an alternative to conventional surgical removal of intestinal obstructions. PMID:25561823

  6. Castleman disease presenting as obstructive jaundice.

    PubMed

    Al-Salamah, Saleh M; Khan, Iftikhar A; Khalid, Kamran; Al-Shakweer, Wafaa A

    2005-01-01

    A 48-year-old Saudi male was admitted with features of obstructive jaundice. Endoscopic retrograde cholangiopancreatography showed stricture in distal common bile duct CBD. Computed tomography scan revealed lymphadenopathy along CBD and in porta hepatis. Cholangiocarcinoma, lymphoma or metastatic deposits were suspected but no definite preoperative diagnosis could be established. Laparotomy disclosed lymph node enlargement in porta hepatis and along the CBD and lesser curvature of the stomach. Triple bypass procedure was performed to relieve the obstruction. Pathological examination of the lymph nodes showed Castleman disease of hyaline vascular type.

  7. The Patient Burden of Bladder Outlet Obstruction after Prostate Cancer Treatment.

    PubMed

    Liberman, Daniel; Jarosek, Stephanie; Virnig, Beth A; Chu, Haitao; Elliott, Sean P

    2016-05-01

    Bladder outlet obstruction after prostate cancer therapy imposes a significant burden on health and quality of life in men. Our objective was to describe the burden of bladder outlet obstruction after prostate cancer therapy by detailing the type of procedures performed and how often those procedures were repeated in men with recurrent bladder outlet obstruction. Using SEER (Surveillance, Epidemiology and End Results)-Medicare linked data from 1992 to 2007 with followup through 2009 we identified 12,676 men who underwent at least 1 bladder outlet obstruction procedure after prostate cancer therapy, including external beam radiotherapy in 3,994, brachytherapy in 1,485, brachytherapy plus external beam radiotherapy in 1,847, radical prostatectomy in 4,736, radical prostatectomy plus external beam radiotherapy in 369 and cryotherapy in 245. Histogram, incidence rates and Cox proportional hazards models with repeat events analysis were done to describe the burden of repeat bladder outlet obstruction treatments stratified by prostate cancer therapy type. We describe the type of bladder outlet obstruction surgery grouped by level of invasiveness. At a median followup of 8.8 years 44.6% of men underwent 2 or more bladder outlet obstruction procedures. Compared to men who underwent radical prostatectomy those treated with brachytherapy and brachytherapy plus external beam radiotherapy were at increased adjusted risk for repeat bladder outlet obstruction treatment (HR 1.2 and 1.32, respectively, each p <0.05). After stricture incision the men treated with radical prostatectomy or radical prostatectomy plus external beam radiotherapy were most likely to undergo dilation at a rate of 34.7% to 35.0%. Stricture resection/ablation was more common after brachytherapy, external beam radiotherapy or brachytherapy plus external beam radiotherapy at a rate of 28.9% to 41.2%. Almost half of the men with bladder outlet obstruction after prostate cancer therapy undergo more than 1

  8. Danazol in the management of ureteral obstruction secondary to endometriosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivlin, M.E.; Krueger, R.P.; Wiser, W.L.

    1985-08-01

    A case is reported in which a woman was diagnosed with ureteral obstruction secondary to endometriosis after cystourethrogram, retrograde pyelogram and a renal scan. After unsuccessful treatment with danazol, a retroperitoneal ureteroneocystotomy was performed. The ureter was found to be obstructed by dense fibrous tissue that contained endometrial glands. It was concluded that danazol is unlikely to relieve endometriotic ureteric obstruction once dense fibrosis has occurred. 8 references, 2 figures.

  9. Arterially Delivered Mesenchymal Stem Cells Prevent Obstruction-Induced Renal Fibrosis

    PubMed Central

    Asanuma, Hiroshi; Vanderbrink, Brian A.; Campbell, Matthew T.; Hile, Karen L.; Zhang, Hongji; Meldrum, Daniel R.; Meldrum, Kirstan K.

    2010-01-01

    Purpose Mesenchymal stem cells (MSCs) hold promise for the treatment of renal disease. While MSCs have been shown to accelerate recovery and prevent acute renal failure in multiple disease models, the effect of MSC therapy on chronic obstruction-induced renal fibrosis has not previously been evaluated. Materials and Methods Male Sprague-Dawley rats underwent renal artery injection of vehicle or fluorescent-labeled human bone marrow-derived MSCs immediately prior to sham operation or induction of left ureteral obstruction (UUO). One or 4 weeks later, the kidneys were harvested and the renal cortex analyzed for evidence of stem cell infiltration, epithelial-mesenchymal transition (EMT) as evidenced by E-cadherin/α-smooth muscle actin (α-SMA) expression and fibroblast specific protein (FSP+) staining, renal fibrosis (collagen content, Masson’s trichrome staining), and cytokine and growth factor activity (ELISA and real time RT-PCR). Results Fluorescent-labeled MSCs were detected in the interstitium of the kidney up to 4 weeks post-obstruction. Arterially delivered MSCs significantly reduced obstruction-induced α-SMA expression, FSP+ cell accumulation, total collagen content, and tubulointerstitial fibrosis, while simultaneously preserving E-cadherin expression, suggesting that MSCs prevent obstruction-induced EMT and renal fibrosis. Exogenous MSCs reduced obstruction-induced tumor necrosis factor-α (TNF-α) levels, but did not alter transforming growth factor-β1 (TGF-β1), vascular endothelial growth factor (VEGF), interleukin-10 (IL-10), fibroblast growth factor (FGF), or hepatocyte growth factor (HGF) expression. Conclusions Human bone marrow-derived MSCs remain viable several weeks after delivery into the kidney and provide protection against obstruction-induced EMT and chronic renal fibrosis. While the mechanism of MSCs-induced renal protection during obstruction remains unclear, our results demonstrate that alterations in TNF-α production may be involved

  10. Detection of DNA damage based on metal-mediated molecular beacon and DNA strands displacement reaction

    NASA Astrophysics Data System (ADS)

    Xiong, Yanxiang; Wei, Min; Wei, Wei; Yin, Lihong; Pu, Yuepu; Liu, Songqin

    2014-01-01

    DNA hairpin structure probes are usually designed by forming intra-molecular duplex based on Watson-Crick hydrogen bonds. In this paper, a molecular beacon based on silver ions-mediated cytosine-Ag+-cytosine base pairs was used to detect DNA. The inherent characteristic of the metal ligation facilitated the design of functional probe and the adjustment of its binding strength compared to traditional DNA hairpin structure probes, which make it be used to detect DNA in a simple, rapid and easy way with the help of DNA strands displacement reaction. The method was sensitive and also possesses the good specificity to differentiate the single base mismatched DNA from the complementary DNA. It was also successfully applied to study the damage effect of classic genotoxicity chemicals such as styrene oxide and sodium arsenite on DNA, which was significant in food science, environmental science and pharmaceutical science.

  11. Murine model of long-term obstructive jaundice.

    PubMed

    Aoki, Hiroaki; Aoki, Masayo; Yang, Jing; Katsuta, Eriko; Mukhopadhyay, Partha; Ramanathan, Rajesh; Woelfel, Ingrid A; Wang, Xuan; Spiegel, Sarah; Zhou, Huiping; Takabe, Kazuaki

    2016-11-01

    With the recent emergence of conjugated bile acids as signaling molecules in cancer, a murine model of obstructive jaundice by cholestasis with long-term survival is in need. Here, we investigated the characteristics of three murine models of obstructive jaundice. C57BL/6J mice were used for total ligation of the common bile duct (tCL), partial common bile duct ligation (pCL), and ligation of left and median hepatic bile duct with gallbladder removal (LMHL) models. Survival was assessed by Kaplan-Meier method. Fibrotic change was determined by Masson-Trichrome staining and Collagen expression. Overall, 70% (7 of 10) of tCL mice died by day 7, whereas majority 67% (10 of 15) of pCL mice survived with loss of jaundice. A total of 19% (3 of 16) of LMHL mice died; however, jaundice continued beyond day 14, with survival of more than a month. Compensatory enlargement of the right lobe was observed in both pCL and LMHL models. The pCL model demonstrated acute inflammation due to obstructive jaundice 3 d after ligation but jaundice rapidly decreased by day 7. The LHML group developed portal hypertension and severe fibrosis by day 14 in addition to prolonged jaundice. The standard tCL model is too unstable with high mortality for long-term studies. pCL may be an appropriate model for acute inflammation with obstructive jaundice, but long-term survivors are no longer jaundiced. The LHML model was identified to be the most feasible model to study the effect of long-term obstructive jaundice. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Double obstruction of ureter: A diagnostic challenge.

    PubMed

    Halder, Pankaj; Shukla, Ram Mohan; Mandal, Kartik Chandra; Mukhopadhyay, Biswanath; Barman, Shibsankar

    2014-07-01

    Isolated obstruction of the ureteropelvic junction and the vesico-ureteric junction are the two most common causes of hydronephrosis in a pediatric population.[1] They do not pose diagnostic difficulties when are present alone but when together can be difficult to diagnose. Here, we discuss the problems we faced when we encountered these two anomalies in the same ureter and the way in which we managed them. To assess the difficulties in diagnosis of pediatric patients who present with both ureteropelvic junction obstruction (UPJO) and vesico-ureteric junction obstruction (VUJO) in the ipsilateral ureter and their management protocol. This is a retrospective study. The study period is from 1 January 2004 to 31 December 2011. Out of 254 children who were diagnosed to have hydronephrosis due to UPJO in our institute, 5 patients (in the age range of 5 to 10 years) had both UPJO and VUJO in the ipsilateral ureter. The problems we faced in diagnosing the two conditions are mentioned with a literature review. Operative intervention was used in four out of five patients; none of the patients had an accurate diagnosis before surgery. All patients were suspected of having double obstruction during pyeloplasty when appropriate size double J stent could not be negotiated through the vesicoureteric junction into the bladder. Postoperative nephrostogram confirmed the diagnosis in all patients. Children with double obstruction of the ipsilateral ureter present as a diagnostic dilemma. Because of the rarity of this condition it can escape the eye of even an astute clinician. Early diagnosis can be made if this condition is kept in mind while treating any hydronephrosis due to UPJO or UVJO.

  13. Clinical presentation and outcome of cats with circumcaval ureters associated with a ureteral obstruction.

    PubMed

    Steinhaus, J; Berent, A C; Weisse, C; Eatroff, A; Donovan, T; Haddad, J; Bagley, D

    2015-01-01

    Circumcaval ureters (CU) are a rare embryological malformation resulting in ventral displacement of the caudal vena cava, which crosses the ureter, potentially causing a ureteral stricture. To evaluate cats with obstructed CU(s) and report the presenting signs, diagnostics, treatment(s), and outcomes. Cats with obstructed CU(s) were compared to ureterally obstructed cats without CU(s). 193 cats; 22 circumcaval obstructed (Group 1); 106 non-circumcaval obstructed (Group 2); 65 non-obstructed necropsy cases (Group 3). Retrospective study, review of medical records for cats treated for benign ureteral obstructions from AMC and University of Pennsylvania between 2009 and 2013. surgical treatment of benign ureteral obstruction, complete medical record including radiographic, ultrasonographic, biochemistry, and surgical findings. Seventeen percent (22/128) of obstructed cats had a CU (80% right-sided) compared to 14% (9/65) non-obstructed necropsy cats (89% right-sided). Clinical presentation, radiographic findings, and creatinine were not statistically different between Groups 1 and 2. Strictures were a statistically more common (40%) cause of ureteral obstruction in Group 1 compared to Group 2 (17%) (P = .01). The MST for Groups 1 and 2 after ureteral decompression was 923 and 762 days, respectively (P = .62), with the MST for death secondary to kidney disease in both groups being >1,442 days. Re-obstruction was the most common complication in Group 1 (24%) occurring more commonly in ureters of cats treated with a ureteral stent(s) (44%) compared to the subcutaneous ureteral bypass (SUB) device (8%) (P = .01). Ureteral obstructions in cats with a CU(s) have a similar outcome to those cats with a ureteral obstruction and normal ureteral anatomy. Long-term prognosis is good for benign ureteral obstructions treated with a double pigtail stent or a SUB device. The SUB device re-obstructed less commonly than the ureteral stent, especially when a ureteral stricture was

  14. Unexplained Obstruction of an Integrated Cardiotomy Filter During Cardiopulmonary Bypass.

    PubMed

    Alwardt, Cory M; Wilson, Donald S; Pajaro, Octavio E

    2017-03-01

    Cardiopulmonary bypass (CPB) is considered relatively safe in most cases, yet is not complication free. We present a case of an integrated cardiotomy filter obstruction during CPB, requiring circuit reconfiguration. Approximately an hour after uneventful initiation of CPB the integrated cardiotomy filter became obstructed over several minutes, requiring circuit reconfiguration using an external cardiotomy filter to maintain functionality. Following reconfiguration, CPB was maintained with a fully functional circuit allowing safe patient support throughout the remainder of CPB. Postoperatively, there was no sign of thrombus or mechanical obstruction of the filter, which was sent to the manufacturer for analysis. The cause of the obstruction was unclear even after chemical analysis, visual inspection, and a review of all techniques and products to which the patient was exposed. The patient had a generally routine hospital stay, with no signs or symptoms related to the incident. To our knowledge, this is the first report describing an obstructed integrated cardiotomy filter. An appropriate readiness plan for such an incident includes proper venting of the filter chamber, a method for detecting an obstruction, and a plan for circuit reconfiguration. This case illustrates the need for a formal reporting structure for incidents or "near miss" incidents during CPB.

  15. Tuberculosis associates with both airflow obstruction and low lung function: BOLD results.

    PubMed

    Amaral, André F S; Coton, Sonia; Kato, Bernet; Tan, Wan C; Studnicka, Michael; Janson, Christer; Gislason, Thorarinn; Mannino, David; Bateman, Eric D; Buist, Sonia; Burney, Peter G J

    2015-10-01

    In small studies and cases series, a history of tuberculosis has been associated with both airflow obstruction, which is characteristic of chronic obstructive pulmonary disease, and restrictive patterns on spirometry. The objective of the present study was to assess the association between a history of tuberculosis and airflow obstruction and spirometric abnormalities in adults.The study was performed in adults, aged 40 years and above, who took part in the multicentre, cross-sectional, general population-based Burden of Obstructive Lung Disease study, and had provided acceptable post-bronchodilator spirometry measurements and information on a history of tuberculosis. The associations between a history of tuberculosis and airflow obstruction and spirometric restriction were assessed within each participating centre, and estimates combined using meta-analysis. These estimates were stratified by high- and low/middle-income countries, according to gross national income.A self-reported history of tuberculosis was associated with airflow obstruction (adjusted odds ratio 2.51, 95% CI 1.83-3.42) and spirometric restriction (adjusted odds ratio 2.13, 95% CI 1.42-3.19).A history of tuberculosis was associated with both airflow obstruction and spirometric restriction, and should be considered as a potentially important cause of obstructive disease and low lung function, particularly where tuberculosis is common. Copyright ©ERS 2015.

  16. Tuberculosis associates with both airflow obstruction and low lung function: BOLD results

    PubMed Central

    Amaral, André F. S.; Coton, Sonia; Kato, Bernet; Tan, Wan C.; Studnicka, Michael; Janson, Christer; Gislason, Thorarinn; Mannino, David; Bateman, Eric D.; Buist, Sonia; Burney, Peter G. J.

    2015-01-01

    Background In small studies and cases series, a history of tuberculosis has been associated with both airflow obstruction, which is characteristic of chronic obstructive pulmonary disease, and restrictive patterns on spirometry. Objective To assess the association between a history of tuberculosis and airflow obstruction and spirometric abnormalities in adults. Methods The study was performed in adults, aged 40 and above, who took part in the multicentre cross-sectional, general population-based, Burden of Obstructive Lung Disease study, had provided acceptable post-bronchodilator spirometry measurements and information on a history of tuberculosis. The associations between a history of tuberculosis and airflow obstruction and spirometric restriction were assessed within each participating centre, and estimates combined using meta-analysis. These estimates were stratified by high and low/middle income countries, according to gross national income. Results A self-reported history of tuberculosis was associated with airflow obstruction (adjusted odds ratio = 2.51, 95% confidence interval 1.83-3.42) and spirometric restriction (adjusted odds ratio = 2.13, 95% confidence interval 1.42-3.19). Conclusion A history of tuberculosis was associated with both airflow obstruction and spirometric restriction, and should be considered as a potentially important cause of obstructive disease and low lung function, particularly where tuberculosis is common. PMID:26113680

  17. Laparoscopic gastropexy relieves symptoms of obstructed gastric volvulus in highoperative risk patients.

    PubMed

    Yates, Robert B; Hinojosa, Marcelo W; Wright, Andrew S; Pellegrini, Carlos A; Oelschlager, Brant K

    2015-05-01

    Operative repair of obstructive gastric volvulus is challenging. In high-operative risk patients with obstructive gastric volvulus, we perform laparoscopic reduction of gastric volvulus and anterior abdominal wall sutured gastropexy. This case series reports our experience with this operation. We reviewed the charts of all patients who presented with obstructive gastric volvulus and underwent laparoscopic gastropexy between 2007 and 2013. Eleven patients underwent laparoscopic gastropexy. Median age was 83 years (50 to 92). Six patients presented with chronic obstruction; 5 presented with acute obstruction. Median postoperative hospitalization was 2 days (1 to 39). Two patients required reoperation for displaced gastrostomy tubes. At median follow-up of 3 months (2 weeks to 57 months), all patients remained free of gastric obstructive symptoms and recurrent episodes of volvulus. Only 1 patient received nutrition via gastrostomy tube. Laparoscopic gastropexy can treat obstructed gastric volvulus in highoperative risk patients. Because of associated morbidity, gastrostomy tubes should be placed selectively. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Hypertension, snoring, and obstructive sleep apnoea during pregnancy: a cohort study.

    PubMed

    O'Brien, L M; Bullough, A S; Chames, M C; Shelgikar, A V; Armitage, R; Guilleminualt, C; Sullivan, C E; Johnson, T R B; Chervin, R D

    2014-12-01

    To assess the frequency of obstructive sleep apnoea among women with and without hypertensive disorders of pregnancy. Cohort study. Obstetric clinics at an academic medical centre. Pregnant women with hypertensive disorders (chronic hypertension, gestational hypertension, or pre-eclampsia) and women who were normotensive. Women completed a questionnaire about habitual snoring and underwent overnight ambulatory polysomnography. The presence and severity of obstructive sleep apnoea. Obstructive sleep apnoea was found among 21 of 51 women with hypertensive disorders (41%), but in only three of 16 women who were normotensive (19%, chi-square test, P=0.005). [Author correction added on 16 June 2014, after first online publication: Results mentioned in the abstract were amended.] Non-snoring women with hypertensive disorders typically had mild obstructive sleep apnoea, but >25% of snoring women with hypertensive disorders had moderate to severe obstructive sleep apnoea. Among women with hypertensive disorders, the mean apnoea/hypopnoea index was substantially higher in snorers than in non-snorers (19.9±34.1 versus 3.4±3.1, P=0.013), and the oxyhaemoglobin saturation nadir was significantly lower (86.4±6.6 versus 90.2±3.5, P=0.021). Among women with hypertensive disorders, after stratification by obesity, the pooled relative risk for obstructive sleep apnoea in snoring women with hypertension compared with non-snoring women with hypertension was 2.0 (95% CI 1.4-2.8). Pregnant women with hypertension are at high risk for unrecognised obstructive sleep apnoea. Although longitudinal and intervention studies are urgently needed, given the known relationship between obstructive sleep apnoea and hypertension in the general population, it would seem pertinent that hypertensive pregnant women who snore should be tested for obstructive sleep apnoea, a condition believed to cause or promote hypertension. © 2014 Royal College of Obstetricians and Gynaecologists.

  19. Fetal tracheolaryngeal airway obstruction: prenatal evaluation by sonography and MRI

    PubMed Central

    Courtier, Jesse; Poder, Liina; Wang, Zhen J.; Westphalen, Antonio C.; Yeh, Benjamin M.

    2010-01-01

    We reviewed the sonographic and MRI findings of tracheolaryngeal obstruction in the fetus. Conditions that can cause tracheolaryngeal obstruction include extrinsic causes such as lymphatic malformation, cervical teratoma and vascular rings and intrinsic causes such as congenital high airway obstruction syndrome (CHAOS). Accurate distinction of these conditions by sonography or MRI can help facilitate parental counseling and management, including the decision to utilize the ex utero intrapartum treatment (EXIT) procedure. PMID:20737145

  20. Intestinal obstruction caused by Taenia taeniaeformis infection in a cat.

    PubMed

    Wilcox, Rebbecca S; Bowman, Dwight D; Barr, Stephen C; Euclid, James M

    2009-01-01

    An adult domestic shorthair (DSH) cat was presented with acute vomiting, anorexia, lethargy, and dyspnea. The cat's clinical status worsened over 24 hours with conservative medical management. An exploratory celiotomy was performed. Acute intestinal obstruction resulting from infection with Taenia (T.) taeniaeformis was diagnosed. Surgical removal of the cestodes via multiple enterotomies resolved the obstruction. This paper reports, for the first time, small intestinal obstruction caused by T. taeniaeformis infection in a cat.