Sample records for obstruction tricuspid valve

  1. Successful management of multiple permanent pacemaker complications – infection, 13 year old silent lead perforation and exteriorisation following failed percutaneous extraction, superior vena cava obstruction, tricuspid valve endocarditis, pulmonary embolism and prosthetic tricuspid valve thrombosis

    PubMed Central

    Kaul, Pankaj; Adluri, Krishna; Javangula, Kalyana; Baig, Wasir

    2009-01-01

    A 59 year old man underwent mechanical tricuspid valve replacement and removal of pacemaker generator along with 4 pacemaker leads for pacemaker endocarditis and superior vena cava obstruction after an earlier percutaneous extraction had to be abandoned, 13 years ago, due to cardiac arrest, accompanied by silent, unsuspected right atrial perforation and exteriorisation of lead. Postoperative course was complicated by tricuspid valve thrombosis and secondary pulmonary embolism requiring TPA thrombolysis which was instantly successful. A review of literature of pacemaker endocarditis and tricuspid thrombosis along with the relevant management strategies is presented. We believe this case report is unusual on account of non operative management of right atrial lead perforation following an unsuccessful attempt at percutaneous removal of right sided infected pacemaker leads and the incidental discovery of the perforated lead 13 years later at sternotomy, presentation of pacemaker endocarditis with a massive load of vegetations along the entire pacemaker lead tract in superior vena cava, right atrial endocardium, tricuspid valve and right ventricular endocardium, leading to a functional and structural SVC obstruction, requirement of an unusually large dose of warfarin postoperatively occasioned, in all probability, by antibiotic drug interactions, presentation of tricuspid prosthetic valve thrombosis uniquely as vasovagal syncope and isolated hypoxia and near instantaneous resolution of tricuspid prosthetic valve thrombosis with Alteplase thrombolysis. PMID:19239701

  2. Tricuspid regurgitation and right ventricular function after mitral valve surgery with or without concomitant tricuspid valve procedure

    PubMed Central

    Desai, Ravi R.; Vargas Abello, Lina Maria; Klein, Allan L.; Marwick, Thomas H.; Krasuski, Richard A.; Ye, Ying; Nowicki, Edward R.; Rajeswaran, Jeevanantham; Blackstone, Eugene H.; Pettersson, Gösta B.

    2014-01-01

    Objectives To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. Methods From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+(100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. Results In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. Conclusions In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and

  3. Tricuspid regurgitation and right ventricular function after mitral valve surgery with or without concomitant tricuspid valve procedure.

    PubMed

    Desai, Ravi R; Vargas Abello, Lina Maria; Klein, Allan L; Marwick, Thomas H; Krasuski, Richard A; Ye, Ying; Nowicki, Edward R; Rajeswaran, Jeevanantham; Blackstone, Eugene H; Pettersson, Gösta B

    2013-11-01

    To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+ (100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+ or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant

  4. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    PubMed

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. [Tricuspid valve insufficiency: what should be done?].

    PubMed

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  6. Absence of posterior tricuspid valve leaflet and valve reconstruction

    PubMed Central

    Komoda, Takeshi; Stamm, Christof; Fleck, Eckart; Hetzer, Roland

    2012-01-01

    We report a rare case of the absence of a posterior tricuspid valve leaflet. A male patient, aged 46, suffering from severe tricuspid valve regurgitation (TR) of unknown aetiology and atrial septal aneurysm was referred to our hospital for surgery. On surgical inspection, the posterior tricuspid valve leaflet and its subvalvular apparatus were completely absent and only the valve annulus was seen in the corresponding position. The anterior and septal leaflets were normal. We successfully reconstructed the tricuspid valve as follows: the head of an anterior papillary muscle was approximated to the ventricular septum (Sebening stitch). After the approximation of the centre of the tricuspid annulus of the anterior leaflet to the tricuspid annulus on the opposite side, a sizer of 29 mm in diameter was easily passed through the anterior orifice. The posterior orifice was closed with running sutures (posterior annulorrhaphy after Hetzer). Before these procedures, we attempted to reconstruct the tricuspid valve with a posterior annulorrhaphy alone; however, valve competence was insufficient. A Sebening stitch was necessary to improve the valve competence. Echocardiography showed TR grade 1 at the patient's discharge from hospital and TR grade 1 to 2 at the follow-up, 10 months after the operation. PMID:22419794

  7. Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads.

    PubMed

    Uehara, Kyokun; Minakata, Kenji; Watanabe, Kentaro; Sakaguchi, Hisashi; Yamazaki, Kazuhiro; Ikeda, Tadashi; Sakata, Ryuzo

    2016-07-01

    Tricuspid valve regurgitation due to pacemaker leads is a well-known complication. Although some reports have suggested that pacemaker leads should be surgically explanted, strongly adhered leads cannot always be removed. The aim of this study was to describe our tricuspid valve repair techniques with pacemaker leads left in situ. Our retrospective study investigated 6 consecutive patients who required tricuspid valve surgery for severe regurgitation induced by pacemaker leads. From the operative findings, we identified 3 patterns of tricuspid valve and pacemaker lead involvement. In 3 patients, the leads were caught in the chordae, in 2 patients, tricuspid regurgitation was caused by lead impingement on the septal leaflet, and in 3 patients, tricuspid valve leaflets had been perforated by the pacemaker leads. During surgery, all leads were left in situ after being separated from the leaflet or valvular apparatus. In addition, suture annuloplasty was performed for annular dilatation in all cases. In one patient, the lead was reaffixed to the annulus after the posterior leaflet was cut back towards the annulus, and the leaflet was then closed. There was one hospital death due to sepsis. The degree of tricuspid regurgitation was trivial in all surviving patients at discharge. During a mean follow-up of 21 months, one patient died from pneumonia 20 months after tricuspid valve repair. In patients undergoing tricuspid valve surgery due to severe tricuspid regurgitation caused by pacemaker leads, the leads can be left in situ after proper repair with annuloplasty. © The Author(s) 2016.

  8. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    PubMed

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  9. Combined Tricuspid Valvuloplasty and Superior Cavopulmonary Anastomosis for Repair of Traumatic Tricuspid Valve Injury

    PubMed Central

    Dimas, V. Vivian; Grifka, Ronald G.; Fraser, Charles D.

    2004-01-01

    Chronic tricuspid valve insufficiency secondary to blunt chest trauma is rare in the pediatric population, with fewer than 10 cases reported. Surgical repair has focused on the tricuspid valve. We present 2 cases of traumatic tricuspid valve insufficiency in pediatric patients after blunt chest trauma in whom tricuspid valve repair was performed along with superior cavopulmonary anastomosis. To our knowledge, this is the 1st report of the use of this combination of surgical procedures for repair of traumatic tricuspid regurgitation in either adults or children. PMID:15745295

  10. Percutaneous Valvuloplasty for Bioprosthetic Tricuspid Valve Stenosis

    PubMed Central

    Malhotra, Rohit; Sharma, Anjali; Kakouros, Nikolaos

    2017-01-01

    Percutaneous transcatheter tricuspid balloon valvuloplasty (PTTBV) is an accepted treatment option for symptomatic severe native tricuspid valve stenosis, although surgical tricuspid valve replacement remains the treatment of choice. There have been few reports of successful PTTBV for bioprosthetic tricuspid valve stenosis. We present case reports of 3 patients from our hospital experience. Two of the 3 cases were successful, with lasting clinical improvement, whereas the 3rd patient failed to show a reduction in valve gradient. We describe the standard technique used for PTTBV. We present results from a literature review that identified 16 previously reported cases of PTTBV for bioprosthetic severe tricuspid stenosis, with overall favorable results. We conclude that PTTBV should perhaps be considered for a select patient population in which symptomatic improvement and hemodynamic stability are desired immediately, and particularly for patients who are inoperable or at high surgical risk. PMID:28265212

  11. Reoperations after tricuspid valve repair: re-repair versus replacement

    PubMed Central

    Hwang, Ho Young; Kim, Kyung-Hwan; Kim, Ki-Bong

    2016-01-01

    Background Data demonstrating results of reoperation after initial tricuspid valve repair are scarce. We evaluated outcomes of tricuspid reoperations after tricuspid valve repair and compared the results of tricuspid re-repair with those of tricuspid valve replacement (TVR). Methods From 1994 to 2012, 53 patients (56±15 years, male:female =14:39) underwent tricuspid reoperations due to recurrent tricuspid regurgitation (TR) after initial repair. Twenty-two patients underwent tricuspid re-repair (TAP group) and 31 patients underwent TVR (TVR group). Results Early mortality occurred in 6 patients (11%). Early mortality and incidence of postoperative complications were similar between the 2 groups. There were 14 cases of late mortality including 9 cardiac deaths. Five- and 10-year free from cardiac death rates were 82% and 67%, respectively, without any intergroup difference. Recurrent TR (> moderate) developed in 6 TAP group patients and structural valve deterioration occurred in 1 TVR group patient (P=0.002). Isolated tricuspid valve surgery (P=0.044) and presence of atrial fibrillation during the follow-up (P=0.051) were associated with recurrent TR after re-repair. However, the overall tricuspid valve-related event rates were similar between the 2 groups with 5- and 10-year rates of 61% and 41%, respectively. Conclusions Tricuspid valve reoperation after initial repair resulted in high rates of operative mortality and complications. Long-term event-free rate was similar regardless of the type of surgery. However, great care might be needed when performing re-repair in patients with atrial fibrillation and those who had isolated tricuspid valve disease due to high recurrence of TR after re-repair. PMID:26904221

  12. [Medicinal treatment of tricuspid valve regurgitation].

    PubMed

    Lankeit, M; Keller, K; Tschöpe, C; Pieske, B

    2017-11-01

    The vast majority of tricuspid valve regurgitations are of low degree without prognostic relevance in healthy individuals; however, morbidity and mortality increase with the degree of regurgitation, which can be secondary to either primary (structural) or secondary (functional) alterations of the valve. Due to the frequent lack of symptoms, echocardiographic examinations should be annually performed in patients with higher degree (at least moderate) tricuspid valve regurgitation, in particular in the presence of risk factors. Individual therapeutic management strategies should consider the etiology of the tricuspid valve regurgitation, the degree of regurgitation, the valve pathology and the risk-to-benefit ratio of the envisaged therapeutic procedure. Medicinal treatment options for tricuspid valve regurgitation are limited and generalized recommendations cannot be provided due to the lack of conclusive clinical trials. Symptomatic therapeutic measures encompass especially (loop) diuretics for the reduction of preload and afterload of the right ventricle. Pharmaceutical reduction of the heart rate should be avoided in patients with right heart insufficiency. While symptomatic therapeutic measures are often associated with only moderate effects, the most effective therapy of tricuspid valve regurgitation consists in the treatment of underlying illnesses, in most cases pulmonary hypertension due to pulmonary arterial hypertension (PAH), left heart disease or acute pulmonary embolism. Based on a number of published clinical studies and licensing of new drugs, treatment options for patients with PAH and heart failure with reduced ejection fraction (HFrEF) have substantially improved during the past years allowing for a differentiated, individualized management.

  13. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    PubMed

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p < 0.0001), tricuspid valve regurgitation (mean 2.33 vs 1.3, p < 0.0001), and in right ventricular dilation, volume, and area. There was no difference in the degree of tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve

  14. Morphometric analysis of tricuspid valve: An Indian perspective

    PubMed Central

    Kalyani, R.; Thej, M. J.; Prabhakar, K.; Venkatesh, T. K.; Thomas, A. K.; Kiran, J.

    2012-01-01

    Background: The morphometry of tricuspid valve complex is of clinical importance for cardiovascular surgeons and there is scarcity of such data in Indian literature. The study was conducted to record normal tricuspid valve measurements which would serve as baseline data for the Indian population. Material and Methods: The study was carried out on 100 formalin fixed hearts without any pathology from patients who had died of non-vascular causes and whose age ranged from 8 to 85 yrs. The hearts were grouped into three cohorts corresponding to age, 54 hearts aged between 8 to 40 yrs, 42 hearts aged between 41 to 64 yrs and 4 hearts aged 65 yrs and above. Dissection was performed according to standard autopsy techniques. The measurements were recorded using a flexible millimeter ruler and surgical suture material. The dimensions measured were the attachment lengths of anterior, posterior and septal leaflets. The circumference of the valve along with the frontal and sagittal dimensions was measured. Area of the valve expressed as a triangle and as an ellipse was calculated. Results: The measurements obtained were assessed using SPSS software. Statistically significant increase in tricuspid valve measurements were observed with advancing age both in men and women. In younger hearts the tricuspid valve resembled a triangle and with advancing age the tricuspid valve became more elliptical in shape. Conclusion: We hope this study will serve as baseline data for the tricuspid valve measurements in the Indian population and it will be of clinical use for patients with various tricuspid valve abnormalities. PMID:23225976

  15. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    PubMed Central

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  16. Cardioscopic tricuspid valve repair in a beating ovine heart.

    PubMed

    Umakanthan, Ramanan; Ghanta, Ravi K; Rangaraj, Aravind T; Lee, Lawrence S; Laurence, Rita G; Fox, John A; Mihaljevic, Tomislav; Bolman, Ralph M; Cohn, Lawrence H; Chen, Frederick Y

    2009-04-01

    Open heart surgery is commonly associated with cardiopulmonary bypass and cardioplegic arrest. The attendant risks of cardiopulmonary bypass may be prohibitive in high-risk patients. We present a novel endoscopic technique of performing tricuspid valve repair without cardiopulmonary bypass in a beating ovine heart. Six sheep underwent sternotomy and creation of a right heart shunt to eliminate right atrial and right ventricular blood for clear visualization. The superior vena cava, inferior vena cava, pulmonary artery, and coronary sinus were cannulated, and the blood flow from these vessels was shunted into the pulmonary artery via a roller pump. The posterior leaflet of the tricuspid valve was partially excised to create tricuspid regurgitation, which was confirmed by Doppler echocardiography. A 7.0-mm fiberoptic videoscope was inserted into the right atrium to visualize the tricuspid valve. Under cardioscopic vision, an endoscopic needle driver was inserted into the right atrium, and a concentric stitch was placed along the posterior annulus to bicuspidize the tricuspid valve. Doppler echocardiography confirmed reduction of tricuspid regurgitation. All animals successfully underwent and tolerated the surgical procedure. The right heart shunt generated a bloodless field, facilitating cardioscopic tricuspid valve visualization. The endoscopic stitch resulted in annular plication and functional tricuspid valve bicuspidization, significantly reducing the degree of tricuspid regurgitation. Cardioscopy enables less invasive, beating-heart tricuspid valve surgery in an ovine model. This technique may be useful in performing right heart surgery without cardiopulmonary bypass in high-risk patients.

  17. Valve repair for traumatic tricuspid regurgitation.

    PubMed

    Maisano, F; Lorusso, R; Sandrelli, L; Torracca, L; Coletti, G; La Canna, G; Alfieri, O

    1996-01-01

    The review of six cases of valve repair for traumatic tricuspid regurgitation in our institution and 74 in the literature in order to assess effective methods of treating this lesion. Tricuspid valve regurgitation is a rare complication of blunt chest trauma. Optimal treatment for this condition is still controversial ranging from long-term medical therapy to early surgical correction. We followed the cases of six consecutive patients with post-traumatic tricuspid incompetence who were successfully treated with reparative techniques. All patients were male and their ages ranged from 18 years to 42 years. Valve regurgitation was always secondary to blunt chest trauma due to motor vehicle accident. The mechanism of valve insufficiency was invariably anterior leaflet prolapse due to chordal or papillary muscle rupture associated with annular dilatation. Surgical procedures included Carpentier ring implant (5 patients), Bex posterior annuloplasty (1 patient), implant of artificial chordae (4 patients), papillary muscle reinsertion (2 patients), commissuroplasty (1 patient) and "artificial double orifice" technique (1 patient). Tricuspid insufficiency improved in all patients after the correction. No complications were recorded and all patients were asymptomatic at the follow-up. Since post-traumatic tricuspid regurgitation is effectively correctable with reparative techniques, early operation is recommended to relieve symptoms and to prevent right ventricular dysfunction.

  18. [Tricuspid valve regurgitation : Indications and operative techniques].

    PubMed

    Lange, R; Piazza, N; Günther, T

    2017-11-01

    Functional tricuspid valve (TV) regurgitation secondary to left heart disease (e.g. mitral insufficiency and stenosis) is observed in 75% of the patients with TV regurgitation and is thus the most common etiology; therefore, the majority of patients who require TV surgery, undergo concomitant mitral and/or aortic valve surgery. Uncorrected moderate and severe TV regurgitation may persist or even worsen after mitral valve surgery, leading to progressive heart failure and death. Patients with moderate to severe TV regurgitation show a 3-year survival rate of 40%. Surgery is indicated in patients with severe TV regurgitation undergoing left-sided valve surgery and in patients with severe isolated primary regurgitation without severe right ventricular (RV) dysfunction. For patients requiring mitral valve surgery, tricuspid valve annuloplasty should be considered even in the absence of significant regurgitation, when severe annular dilatation (≥40 mm or >21 mm/m 2 ) is present. Functional TV regurgitation is primarily treated with valve reconstruction which carries a lower perioperative risk than valve replacement. Valve replacement is rarely required. Tricuspid valve repair with ring annuloplasty is associated with better survival and a lower reoperation rate than suture annuloplasty. Long-term results are not available. The severity of the heart insufficiency and comorbidities (e.g. renal failure and liver dysfunction) are the essential determinants of operative mortality and long-term survival. Tricuspid valve reoperations are rarely necessary and associated with a considerable mortality.

  19. Identical tricuspid ring sizing in simultaneous functional tricuspid and mitral valve repair: A simple and effective strategy.

    PubMed

    Huffman, Lynn C; Nelson, Jennifer S; Lehman, April N; Krajacic, Marguerite C; Bolling, Steven F

    2014-02-01

    Mitral valve repair for functional mitral regurgitation is common. Concomitant tricuspid valve repair for associated functional tricuspid regurgitation has gained favor. Controversy exists regarding annuloplasty sizing for tricuspid valve repair. Patients with heart failure having functional mitral regurgitation at the University of Michigan and undergoing mitral valve repair and tricuspid valve repair using identical sized annuloplasty rings between April 2007 and January 2012 were identified. Demographic and clinical records were retrospectively reviewed. Institutional review board approval was obtained for this study. Fifty-three patients met inclusion criteria. Mean age was 65 ± 1.7 years. Preoperative New York Heart Association class was III or IV in 81% (43) and mean left ventricular ejection fraction was 33% ± 2.2%. All patients had moderate or greater mitral regurgitation preoperatively and moderate or severe tricuspid regurgitation or a preoperative tricuspid annulus diameter greater than 40 mm. There was no 30-day mortality. Mean immediate postoperative tricuspid valve gradient was 1.75 ± 0.12 mm Hg and was 2.3 ± 0.19 mm Hg at 4 weeks. Four weeks postoperatively 88% (42/48) of patients had tricuspid regurgitation considered to be mild or less. There was no significant decline in right ventricular function by echocardiography over this time period. Functional tricuspid regurgitation can be repaired using an undersized rigid annuloplasty ring. Our data suggest that an identical sizing strategy can be used for tricuspid valve repair, as was used for mitral valve repair, without development of tricuspid stenosis or negative effect on right ventricular function. This method seems to prevent recurrence of significant tricuspid regurgitation. The technique we describe provides effective and reproducible results. Copyright © 2014 The American Association for Thoracic Surgery. All rights reserved.

  20. Repair of Tricuspid Valve Leaflet With CardioCel Patch After Traumatic Tricuspid Regurgitation.

    PubMed

    Konstantinidou, Maria Kalliopi; Moat, Neil

    2017-09-01

    Posttraumatic tricuspid valve regurgitation (TR) is a rare entity and is almost always associated with blunt chest trauma. It is usually identified by transthoracic echocardiography after the manifestation of clinical symptoms of heart failure. Treatment varies from long-term medical therapy and observation to surgical correction with tricuspid valve replacement or repair. We describe the case of a 26-year-old man who was involved in a major road traffic accident and was referred for surgical repair a year later because of severe posttraumatic TR. The tricuspid valve was successfully reconstructed with a CardioCel patch, Gore-Tex neochordae, and a tricuspid ring. The patient recovered well. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Severe right ventricular and tricuspid valve dysfunction after pericardiocentesis.

    PubMed

    Kuroda, Maiko; Amano, Masashi; Enomoto, Soichiro; Miyake, Makoto; Kondo, Hirokazu; Tamura, Toshihiro; Kaitani, Kazuaki; Izumi, Chisato; Nakagawa, Yoshihisa

    2016-10-01

    Pericardiocentesis is performed to treat cardiac tamponade or diagnose the cause of pericardial effusion. Cardiogenic shock with right ventricular (RV) dysfunction is a rare complication after pericardiocentesis. We report a case of an 82-year-old man who suddenly suffered cardiopulmonary arrest 12 h after pericardiocentesis. A transthoracic echocardiogram showed remarkable RV dysfunction and tricuspid valve dysfunction. Tricuspid valve closure was severely impaired, and the tricuspid regurgitation signal showed laminar flow with an early peak. However, after treatment with high-dose inotropic drugs, hemodynamic parameters gradually recovered. A transthoracic echocardiogram performed 24 h later showed improved motion of the RV and the tricuspid valve, resulting in a reduction in tricuspid regurgitation. RV and tricuspid valve dysfunction after pericardiocentesis needs to be recognized as a critical complication. Physicians also need to pay attention to not only the amount of drainage but also underlying RV dysfunction.

  2. All you need to know about the tricuspid valve: Tricuspid valve imaging and tricuspid regurgitation analysis.

    PubMed

    Huttin, Olivier; Voilliot, Damien; Mandry, Damien; Venner, Clément; Juillière, Yves; Selton-Suty, Christine

    2016-01-01

    The acknowledgment of tricuspid regurgitation (TR) as a stand-alone and progressive entity, worsening the prognosis of patients whatever its aetiology, has led to renewed interest in the tricuspid-right ventricular complex. The tricuspid valve (TV) is a complex, dynamic and changing structure. As the TV is not easy to analyse, three-dimensional imaging, cardiac magnetic resonance imaging and computed tomography scans may add to two-dimensional transthoracic and transoesophageal echocardiographic data in the analysis of TR. Not only the severity of TR, but also its mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. TR is functional and is a satellite of left-sided heart disease and/or elevated pulmonary artery pressure most of the time; a particular form is characterized by TR worsening after left-sided valve surgery, which has been shown to impair patient prognosis. A better description of TV anatomy and function by multimodality imaging should help with the appropriate selection of patients who will benefit from either surgical TV repair/replacement or a percutaneous procedure for TR, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. [Long-term effects of permanent pacemaker implantation on tricuspid valve regurgitation].

    PubMed

    Ren, Chong-lei; Wang, Yao; Wang, Rong; Li, Bo-jun; Geng, Ren-yi; Gao, Chang-qing

    2012-08-14

    To explore the long-term effects of permanent pacemaker implantation (PPI) on tricuspid valve regurgitation (TR) in Chinese patients so as to determine the incidence and related factors, evaluate its effects on heart structure and function and ascertain the exact mechanism of TR after PPI. A total of 430 patients undergoing permanent pacemaker replacement at our hospital between January 2000 and June 2011 were recruited. The patients with isolated atrial lead implantation procedures, significant heart valve disease or chronic obstructive pulmonary disease were excluded. The data of 108 patients who had Doppler echocardiograms performed before the first pacemaker implantation procedure and this pacemaker replacement procedure were obtained and retrospectively analyzed. According to the post-implant grade of TR, the patients were divided into two groups: normal tricuspid (n = 79) and abnormal tricuspid (n = 29). Their clinical characteristics and echocardiographic data between two groups were analyzed and compared. The mean follow-up time (from the first pacemaker implantation) was (13 ± 6) years (range: 4 - 34). Among 108 patients with initially normal tricuspid post-implant, 29 patients (26.9%) developed significant TR during the follow-up. In comparison to those in normal tricuspid group, the patients in abnormal tricuspid group had a longer time from the first pacemaker implantation ((16 ± 7) vs (12 ± 5) years, P = 0.003), more transtricuspid leads (1.31 ± 0.66 vs 1.10 ± 0.30, P = 0.026), larger right atrial size ((38 ± 7) vs (35 ± 4) mm, P = 0.028) and higher prevalence of mild TR and mitral valve regurgitation (MR) pre-implantation (TR: 21% vs 4%, P = 0.015, MR: 28% vs 5%, P = 0.003). The size of right atrium, right ventricle and left atrium in abnormal tricuspid group were more than those in normal tricuspid group. The prevalence of significant MR post-implantation in abnormal tricuspid group was higher than that in normal tricuspid group. The ejection

  4. Percutaneous re-revalvulation of the tricuspid valve.

    PubMed

    Gewillig, Marc; Dubois, Christophe

    2011-04-01

    We report a successful percutaneous revalvulation of a dysfunctional tricuspid bioprothesis in an 8-year-old child. Five years after implanting a 25-mm Carpentier-Edwards valve in the tricuspid position, the prosthesis showed significant dysfunction with clinical right heart failure. A 26-mm Edwards-Sapien XT inverted aortic valve was successfully implanted through a 19F sheath using a jugular approach. Such procedure can significantly postpone the need for surgical replacement of a biological valve. Copyright © 2011 Wiley-Liss, Inc.

  5. Successful replacement of the systemic tricuspid valve with a mechanical valve in a 3-month-old boy with congenitally corrected transposition of the great arteries having a dysplastic tricuspid valve.

    PubMed

    Asada, Dai; Ikeda, Kazuyuki; Yamagishi, Masaaki

    2017-04-01

    There are a few reports of successful replacement of the left-sided systemic tricuspid valve with a mechanical valve in small infants with congenitally corrected transposition of the great arteries having Ebstein's anomaly. Tricuspid valve replacement is the preferred option when pulmonary artery banding, performed as a prelude to performing the double-switch operation, is not feasible because of severe heart failure caused by tricuspid regurgitation.

  6. Underlying Rheumatic Disease: An Important Determinant of Outcome in Tricuspid Valve Repair.

    PubMed

    Munasur, Mandhir; Naidoo, Datshana

    2016-03-01

    Tricuspid regurgitation (TR) accompanying severe left-sided valve disease occurs on a functional basis, secondary to pulmonary hypertension and tricuspid annular dilatation. In the context of endemic left-sided rheumatic heart disease, non-recognition of organic disease of the tricuspid valve may adversely influence surgical decision-making, resulting in suboptimal outcomes. A retrospective analysis of the perioperative and follow up data of 30 patients who underwent tricuspid valve surgery with concomitant left-sided valve replacement was undertaken. Preoperative evaluation by two-dimensional transthoracic echocardiography was routinely employed. Outcomes were analyzed by evaluation of the perioperative and two-year follow up clinical and echocardiographic data. All subjects had severe TR. Mixed tricuspid valve disease occurred in 11 subjects (36.7%). Tricuspid valve repair was performed in 28 patients. A significant improvement (p <0.05) in the following parameters occurred at six weeks postoperatively: NYHA functional class, tricuspid annular diameter, systolic pulmonary artery pressure, severity of TR and tricuspid transvalvular gradient. Severe residual postoperative TR occurred in 26.7% of patients, but there were no identifiable predictors for this phenomenon. Severe residual postoperative TR was not associated with major adverse cardiovascular events. Preoperative (p = 0.013) and postoperative (p<0.002) pulmonary hypertension were associated with the development of major adverse cardiovascular events. The technique of tricuspid valve repair was not associated with the occurrence of major adverse cardiovascular events, nor with the development of severe residual postoperative TR. A satisfactory outcome was observed in only 40% of the study population. The coexistence of mixed tricuspid valve disease in rheumatic heart disease patients undergoing left-sided valve surgery is an important determinant of outcome in tricuspid valve repair. The persistence of

  7. Non-functional tricuspid valve disease.

    PubMed

    Adler, Dale S

    2017-05-01

    Only 75% of severe tricuspid regurgitation is classified as functional, or related primarily to pulmonary hypertension, right ventricular dysfunction, or a combination of both. Non-functional tricuspid regurgitation occurs when there is damage to the tricuspid leaflets, chordae, papillary muscles, or annulus, independent of right ventricular dysfunction or pulmonary hypertension. The entities that cause non-functional tricuspid regurgitation include rheumatic and myxomatous disease, acquired and genetic connective tissue disorders, endocarditis, sarcoid, pacing, RV biopsy, blunt trauma, radiation, carcinoid, ergot alkaloids, dopamine agonists, fenfluramine, cardiac tumors, atrial fibrillation, and congenital malformations. Over time, severe tricuspid regurgitation that is initially non-functional, can blend into functional tricuspid regurgitation, related to progressive right ventricular dysfunction. Symptoms and signs, including a falling right ventricular ejection fraction, cardiac cirrhosis, ascites, esophageal varices, and anasarca, may occur insidiously and late, but are associated with substantial morbidity and mortality. Attempted valve repair or replacement at late stages carries a high mortality. Crucial to following patients with severe non-functional tricuspid regurgitation is attention to echo quantification of the tricuspid regurgitation and right ventricular function, patient symptoms, and the physical examination.

  8. Porcine Tricuspid Valve Anatomy and Human Compatibility: Relevance for Preclinical Validation of Novel Valve Interventions.

    PubMed

    Waziri, Farhad; Lyager Nielsen, Sten; Michael Hasenkam, John

    2016-09-01

    Tricuspid regurgitation may be a precursor for heart failure, reduced functional capacity, and poor survival. A human compatible experimental model is required to understand the pathophysiology of the tricuspid valve disease as a basis for validating novel tricuspid valve interventions before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin-fixed porcine hearts obtained from Danish Landrace pigs (body weight 80 kg). All valvular dimensions were compared with human data acquired from literature sources. No difference was seen in the tricuspid annulus circumference between porcine and human hearts (13.0 ± 1.2 cm versus 13.5 ± 1.5 cm; p = NS), or in valve area (5.7 ± 1.6 cm2 versus 5.6 ± 1.0 cm2; p = NS). The majority of chordae types exhibited a larger chordal length and thickness in human hearts compared to porcine hearts. In both species, the anterior papillary muscle (PM) was larger than other PMs in the right ventricle, but muscle length varied greatly (range: 5.2-40.3 mm) and was significantly different in pigs and in humans (12.2 ± 3.2 mm versus 19.2 mm; p <0.001). The porcine tricuspid valve was determined to be a valid model for preclinical animal studies, despite various anatomic differences being noted between porcine and human hearts.

  9. Non-functional tricuspid valve disease

    PubMed Central

    2017-01-01

    Only 75% of severe tricuspid regurgitation is classified as functional, or related primarily to pulmonary hypertension, right ventricular dysfunction, or a combination of both. Non-functional tricuspid regurgitation occurs when there is damage to the tricuspid leaflets, chordae, papillary muscles, or annulus, independent of right ventricular dysfunction or pulmonary hypertension. The entities that cause non-functional tricuspid regurgitation include rheumatic and myxomatous disease, acquired and genetic connective tissue disorders, endocarditis, sarcoid, pacing, RV biopsy, blunt trauma, radiation, carcinoid, ergot alkaloids, dopamine agonists, fenfluramine, cardiac tumors, atrial fibrillation, and congenital malformations. Over time, severe tricuspid regurgitation that is initially non-functional, can blend into functional tricuspid regurgitation, related to progressive right ventricular dysfunction. Symptoms and signs, including a falling right ventricular ejection fraction, cardiac cirrhosis, ascites, esophageal varices, and anasarca, may occur insidiously and late, but are associated with substantial morbidity and mortality. Attempted valve repair or replacement at late stages carries a high mortality. Crucial to following patients with severe non-functional tricuspid regurgitation is attention to echo quantification of the tricuspid regurgitation and right ventricular function, patient symptoms, and the physical examination. PMID:28706863

  10. The tricuspid valve and the right heart: anatomical, pathological and imaging specifications.

    PubMed

    van Rosendael, Philippe J; Delgado, Victoria; Bax, Jeroen J

    2015-09-01

    Transcatheter tricuspid valve repair/replacement is an emerging therapy for patients with symptomatic severe tricuspid regurgitation who are deemed inoperable. Accurate knowledge of the anatomy of the tricuspid valve and right ventricle is key to developing transcatheter techniques. In addition, it is important to understand the mechanistic concept of transcatheter tricuspid valve repair/replacement in order to select the patients who may benefit from it. The severity and mechanism of tricuspid regurgitation, right ventricular function, dimensions of the caval veins and the course of the right coronary artery in relation to the atrioventricular groove are important aspects to be evaluated before embarking on these procedures. The present article reviews current advances in transcatheter approaches for significant tricuspid regurgitation and the role of imaging modalities to characterise the anatomy of the tricuspid valve and right ventricle as well as the underlying pathophysiology of tricuspid regurgitation.

  11. Spontaneous Tricuspid Valve Chordal Rupture in Idiopathic Pulmonary Hypertension.

    PubMed

    Rodrigues, Ana Clara Tude; Afonso, José E; Cordovil, Adriana; Monaco, Claudia; Piveta, Rafael; Cordovil, Rodrigo; Fischer, Claudio H; Vieira, Marcelo; Lira-Filho, Edgar; Morhy, Samira S

    2016-03-01

    Rupture of tricuspid valve is unusual, occurring mainly in the setting of blunt trauma or endomyocardial biopsy. Spontaneous tricuspid valve chordal rupture is particularly rare. We report herein a case of a patient with severe pulmonary hypertension, on the lung transplantation waiting list, who presented with spontaneous chordal rupture, exacerbation of tricuspid insufficiency and worsening of clinical status. Diagnosis and treatment, along with possible mechanisms for this complication, are discussed. © 2015, Wiley Periodicals, Inc.

  12. Prosthetic tricuspid valve dysfunction assessed by three-dimensional transthoracic and transesophageal echocardiography.

    PubMed

    Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi

    2013-09-01

    A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.

  13. Long-Term Follow-Up Study of Temporary Tricuspid Valve Detachment as Approach to VSD Repair without Consequent Tricuspid Dysfunction.

    PubMed

    Lucchese, Gianluca; Rossetti, Lucia; Faggian, Giuseppe; Luciani, Giovanni B

    2016-10-01

    Temporary tricuspid valve detachment improves the operative view of certain congenital ventricular septal defects (VSDs), but its long-term effects on tricuspid valve function are still debated. From 2002 through 2012, we performed a prospective study of 68 children (mean age, 1.28 ± 1.01 yr) who underwent transatrial closure of VSDs following temporary tricuspid valve detachment. Sixty patients had conoventricular and 8 had mid-muscular VSDs. All were in sinus rhythm. Seventeen patients had systemic pulmonary artery pressures. Preoperative echocardiograms showed trivial-to-mild tricuspid regurgitation in 62 patients and tricuspid dysplasia with severe regurgitation in 6 patients. Patients were clinically and echocardiographically monitored at 30 postoperative days, 3 months, 6 months, every 6 months thereafter for the first 2 years, and then once a year. No in-hospital or late death was observed at the median follow-up evaluation of 5.9 years. Mean intensive care unit and hospital stays were 1.6 ± 1.1 and 7.3 ± 2.7 days, respectively. Residual small VSDs occurred in 3 patients, and temporary atrioventricular block in one. After VSD repair, 62 patients (91%) had trivial or mild tricuspid regurgitation, and 6 moderate. Five of these last had severe tricuspid regurgitation preoperatively and had undergone additional tricuspid valve repair during the procedure. The grade of residual tricuspid regurgitation remained stable postoperatively, and no tricuspid stenosis was documented. All patients were in New York Heart Association class I at follow-up. Temporary tricuspid valve detachment is a simple and useful method for a complete visualization of certain VSDs without incurring substantial tricuspid dysfunction.

  14. Long-Term Follow-Up Study of Temporary Tricuspid Valve Detachment as Approach to VSD Repair without Consequent Tricuspid Dysfunction

    PubMed Central

    Rossetti, Lucia; Faggian, Giuseppe; Luciani, Giovanni B.

    2016-01-01

    Temporary tricuspid valve detachment improves the operative view of certain congenital ventricular septal defects (VSDs), but its long-term effects on tricuspid valve function are still debated. From 2002 through 2012, we performed a prospective study of 68 children (mean age, 1.28 ± 1.01 yr) who underwent transatrial closure of VSDs following temporary tricuspid valve detachment. Sixty patients had conoventricular and 8 had mid-muscular VSDs. All were in sinus rhythm. Seventeen patients had systemic pulmonary artery pressures. Preoperative echocardiograms showed trivial-to-mild tricuspid regurgitation in 62 patients and tricuspid dysplasia with severe regurgitation in 6 patients. Patients were clinically and echocardiographically monitored at 30 postoperative days, 3 months, 6 months, every 6 months thereafter for the first 2 years, and then once a year. No in-hospital or late death was observed at the median follow-up evaluation of 5.9 years. Mean intensive care unit and hospital stays were 1.6 ± 1.1 and 7.3 ± 2.7 days, respectively. Residual small VSDs occurred in 3 patients, and temporary atrioventricular block in one. After VSD repair, 62 patients (91%) had trivial or mild tricuspid regurgitation, and 6 moderate. Five of these last had severe tricuspid regurgitation preoperatively and had undergone additional tricuspid valve repair during the procedure. The grade of residual tricuspid regurgitation remained stable postoperatively, and no tricuspid stenosis was documented. All patients were in New York Heart Association class I at follow-up. Temporary tricuspid valve detachment is a simple and useful method for a complete visualization of certain VSDs without incurring substantial tricuspid dysfunction. PMID:27777518

  15. Flail tricuspid valve secondary to blunt chest trauma

    PubMed Central

    Srinivas, Sunil Kumar; Patil, Shivanand; Ramalingam, Rangaraj; Bhairappa, Shivakumar

    2012-01-01

    A 78-year-old man admitted with complaints of breathlessness of 1 year and typical chest pain of 2 months duration. He had a blunt chest trauma 7 years back. Transthoracic echocardiography revealed severe tricuspid regurgitation due to a flail anterior leaflet of the tricuspid valve. It also revealed global left ventricular dysfunction. Flail tricuspid valve causing severe regurgitation is usually due to mechanical trauma. Since it is well tolerated for years, the diagnosis may be delayed or missed entirely. Echocardiography has allowed easier diagnosis of this condition resulting in earlier and, hence, more effective treatment. PMID:22922931

  16. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    PubMed

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  17. Evolving Indications for Tricuspid Valve Surgery

    PubMed Central

    Sales, Virna L.

    2010-01-01

    Opinion statement More attention has been paid to the mitral valve (MV) than the tricuspid valve (TV), and this relative paucity of data has led to confusion regarding the timing of TV surgery. We review the American College of Cardiology/American Heart Association and European Society of Cardiology guidelines to identify areas of concordance (severe tricuspid regurgitation [TR] in a patient undergoing mitral valve surgery); discordance (less than severe TR but with markers for late TR recurrence such as pulmonary hypertension, a dilated TV annulus, atrial fibrillation, permanent transtricuspid pacing wires and others); and disagreement (surgery for primary TR). We provide our perspective from Northwestern University on these issues and where the guidelines are silent (TR in patients undergoing non-mitral valve operations). Finally, we review recent publications on the results of TV repair and replacement. Although there have been scant publications in the past, there have been more useful publications in recent years to guide our decision making. PMID:21063935

  18. Evaluation of tricuspid valve regurgitation following laser lead extraction†.

    PubMed

    Pecha, Simon; Castro, Liesa; Gosau, Nils; Linder, Matthias; Vogler, Julia; Willems, Stephan; Reichenspurner, Hermann; Hakmi, Samer

    2017-06-01

    The objective of this study was to examine the effect of laser lead extraction (LLE) on the development of post-procedural tricuspid regurgitation (TR). Some reports have suggested an increase in TR associated with LLE. We present a series of patients who underwent both, LLE and complete echocardiographic evaluation for TR. A single centre analysis of consecutive patients referred for LLE between January 2012 and August 2015. One hundred and three patients had tricuspid valve function evaluated before the procedure with a transthoracic echocardiography (TTE), during the procedure using transoesophageal echocardiography and postoperatively using a TTE. TR was graded from 0 (none) to 4 (severe). We treated 235 leads in 103 patients, including 118 ventricular leads. Seventy-seven were male (74.8%) and 26 female (25.2%), with a mean age of 65.6 ± 15.4 years. Mean time from initial lead implantation was 98.0 ± 67.3 months. Twenty-one patients (20.4%) had ejection fraction below 30%. No intra-procedural worsening of tricuspid valve function was seen with TEE in any of the patients. Ten patients (9.7%) were found to have TR before LLE that returned to normal valve function after the procedure. Two patients (1.9%) experienced mild TR after the procedure (both with tricuspid valve endocarditis). Ninety-one patients (88.3%) did not experience any significant change of the tricuspid valve function after LLE. Transthoracic and transoesophageal echocardiography findings showed that laser lead extraction was not associated with a significant increase in the incidence of tricuspid valve regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    PubMed

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid

  20. Primary Cardiac Leiomyoma Causing Right Ventricular Obstruction and Tricuspid Regurgitation.

    PubMed

    Careddu, Lucio; Foà, Alberto; Leone, Ornella; Agostini, Valentina; Gargiulo, Gaetano Domenico; Rapezzi, Claudio; Di Bartolomeo, Roberto; Pacini, Davide

    2017-09-01

    We report the unique case of a primary cardiac leiomyoma originating from the right ventricle and involving the tricuspid valve in a 43-year-old woman. Echocardiography showed a giant mass causing severe pulmonary stenosis and tricuspid valve regurgitation. The patient underwent surgical excision and histologic examination revealed a primary cardiac leiomyoma. To the best of our knowledge only three cases of primary cardiac leiomyoma have so far been reported, and this is the first case of primary cardiac leiomyoma involving the tricuspid valve apparatus. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Clinical significance of incomplete tricuspid valve closure seen on two-dimensional echocardiography.

    PubMed

    Gibson, T C; Foale, R A; Guyer, D E; Weyman, A E

    1984-11-01

    Incomplete closure of the tricuspid valve without apparent cusp disease was noted on two-dimensional echocardiography in 31 patients. This abnormality was defined as a failure of the tricuspid valve leaflet tips to reach the plane of the tricuspid valve anulus by at least 1 cm in the standard apical four chamber view at the point of maximal systolic closure. This resulted in a final systolic leaflet position deeper within the right ventricular cavity than is normally seen. The finding was present in the following diagnostic subgroups: Group A, pulmonary hypertension (11 patients); Group B, rheumatic heart disease (4 patients); Group C, dilated cardiomyopathy (9 patients) and Group D, previous myocardial infarction (7 patients). Right atrial, right ventricular and tricuspid anulus measurements were made and compared with those from a group of 67 normal subjects. The results were as follows: right atrial endsystolic area = 27.2 +/- 8.6 cm2 (normal = 13.4 +/- 2.0); right ventricular end-systolic area = 25.6 +/- 8.7 cm2 (normal = 10.9 +/- 2.9); right ventricular end-diastolic area = 31.5 +/- 9.1 cm2 (normal = 20.1 +/- 4.9) and tricuspid valve anular end-systolic dimension = 4.0 +/- 0.6 cm (normal = 2.2 +/- 0.3). The differences from the normal data were all statistically significant (p less than 0.001). Incomplete closure of the tricuspid valve, although a nonspecific diagnostic finding, is primarily associated with right-sided chamber enlargement. Tricuspid regurgitation may be present. The mechanism could be related to geometric changes in valve apparatus dynamics secondary to right-sided cardiac enlargement and tricuspid valve anular dilation.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Tricuspid valve replacement with mechanical prostheses: Short and long-term outcomes.

    PubMed

    Rossello, Xavier; Muñoz-Guijosa, Christian; Mena, Elisabet; Camprecios, Marta; Mendez, Ana B; Borras, Xavier; Padro, Josep M

    2017-09-01

    Tricuspid valve replacement has been associated with high mortality and poor long-term outcomes. We report the preoperative risk factors associated with short and long-term outcomes following tricuspid valve replacement with mechanical prostheses. In 62 patients who underwent mechanical tricuspid valve replacement, clinical, laboratory, and echocardiographic findings were analyzed using both univariate and multivariate analyses to describe operative and long-term mortality. In our population (mean age 59 ± 9.7 years, 82.3% female), most common causes of tricuspid valve disease were rheumatic fever (69.4%) and functional regurgitation (19.4%). Operative and long-term mortality were 17.7 and 33.9%, respectively. Age, diabetes mellitus, and coronary artery disease were independently associated with increased long-term mortality. New York Heart Association (NYHA) class and right heart failure symptoms significantly improved during follow-up. In this series of mechanical tricuspid valve replacements in patients with predominately rheumatic heart disease, operative and long-term mortality were increased; however, survivors had significant improvement in their NYHA class and freedom from right heart failure symptoms. Three preoperative factors (age, diabetes mellitus, and coronary artery disease) were independently associated with long-term mortality. © 2017 Wiley Periodicals, Inc.

  3. Melanocyte pigmentation stiffens murine cardiac tricuspid valve leaflet

    PubMed Central

    Balani, Kantesh; Brito, Flavia C.; Kos, Lidia; Agarwal, Arvind

    2009-01-01

    Pigmentation of murine cardiac tricuspid valve leaflet is associated with melanocyte concentration, which affects its stiffness. Owing to its biological and viscoelastic nature, estimation of the in situ stiffness measurement becomes a challenging task. Therefore, quasi-static and nanodynamic mechanical analysis of the leaflets of the mouse tricuspid valve is performed in the current work. The mechanical properties along the leaflet vary with the degree of pigmentation. Pigmented regions of the valve leaflet that contain melanocytes displayed higher storage modulus (7–10 GPa) than non-pigmented areas (2.5–4 GPa). These results suggest that the presence of melanocytes affects the viscoelastic properties of the mouse atrioventricular valves and are important for their proper functioning in the organism. PMID:19586956

  4. Prosthetic Tricuspid Valve Thrombosis: Three Case Reports and Literature Review

    PubMed Central

    Yaminisharif, Ahmad; Alemzadeh-Ansari, Mohammad Javad; Ahmadi, Seyed Hossein

    2012-01-01

    A common complication of prosthetic heart valves is thrombosis. Although the incidence of prosthetic valve thrombosis (PVT) in the tricuspid position is high, there are not enough data on the management of it, in contrast to left-sided PVT. Here, we describe three cases of tricuspid PVT with three different management approaches: thrombolytic therapy; close observation with oral anticoagulants; and surgery. The first case was a woman who suffered from recurrent PVT, for which we successfully used Tenecteplase for second and third episodes. We employed Tenecteplase in this case for the first time in the therapy of tricuspid PVT. The second case had fixed leaflets in open position while being symptomless. At six months' follow-up, with the patient having taken oral anticoagulants, the motion of the leaflets was restricted and she was symptomfree. The last case was a woman who had a large thrombus in the right atrium immediately after mitral and tricuspid valvular replacement. The patient underwent re-replacement surgery and a new biological valve was implanted in the tricuspid position. Also, we review the literature on the pathology, signs and symptoms, diagnosis, and management of tricuspid PVT. PMID:23323074

  5. [Heart failure provoked by a pacemaker lead-induced tricuspid stenosis].

    PubMed

    Chaudesaygues, E; Ferrini, M; Ritz, B

    2017-04-01

    Tricuspid stenosis (TS) is an uncommon complication of ventricular pacemaker implantation. Mechanisms described by the literature are ventricular inflow obstruction by tricuspid vegetations (endocarditis) or multiple pacemaker leads and fibrosis secondary to mechanical trauma, accounting for perforation or laceration of the TV leaflets, or adherence between redundant loops and valve tissue. We present the case of iatrogenic tricuspid stenosis, observed in a 77-year-old man. Extrinsic tricuspid valve stenosis was detected by transthoracic echocardiography. Further investigations confirmed the intramyocardial lead position. Tricuspid valve stenosis due to transvenous leads are reported to be treated by surgical replacement, surgical valvuloplasty, or percutaneous balloon valvuloplasty. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Clinical outcomes of tricuspid valve repair accompanying left-sided heart disease

    PubMed Central

    Azarnoush, Kasra; Nadeemy, Ahmad S; Pereira, Bruno; Leesar, Massoud A; Lambert, Céline; Azhari, Alaa; Eljezi, Vedat; Dauphin, Nicolas; Geoffroy, Etienne; Camilleri, Lionel

    2017-01-01

    AIM To determine whether the need for additional tricuspid valve repair is an independent risk factor when surgery is required for a left-sided heart disease. METHODS One hundred and eighty patients (68 ± 12 years, 79 males) underwent tricuspid annuoplasty. Cox proportional-hazards regression model for multivariate analysis was performed for variables found significant in univariate analyses. RESULTS Tricuspid regurgitation etiology was functional in 154 cases (86%), organic in 16 cases (9%), and mixed in 10 cases (6%), respectively. Postoperative mortality at 30 days was 11.7%. Mean follow-up was 51.7 mo with survival at 5 years of 73.5%. Risk factors for mortality were acute endocarditis [hazard ratio (HR) = 9.22 (95%CI: 2.87-29.62), P < 0.001], ischemic heart disease requiring myocardial revascularization [HR = 2.79 (1.26-6.20), P = 0.012], and aortic valve stenosis [HR = 2.6 (1.15-5.85), P = 0.021]. Significant predictive factors from univariate analyses were double-valve replacement combined with tricuspid annuloplasty [HR = 2.21 (1.11-4.39), P = 0.003] and preoperatively impaired ejection fraction [HR = 1.98 (1.04-3.92), P = 0.044]. However, successful mitral valve repair showed a protective effect [HR = 0.32 (0.10-0.98), P = 0.046]. Additionally, in instances where tricuspid regurgitation required the need for concomitant tricuspid valve repair, mortality predictor scores such as Euroscore 2 could be shortened to a simple Euroscore-tricuspid comprised of only 7 inputs. The explanation may lie in the fact that significant tricuspid regurgitation following left-sided heart disease represents an independent risk factor encompassing several other factors such as pulmonary arterial hypertension and dyspnea. CONCLUSION Tricuspid annuloplasty should be used more often as a concomitant procedure in the presence of relevant tricuspid regurgitation, although it usually reveals an overly delayed correction of a left-sided heart disease. PMID:29104738

  7. [Foreign body in the tricuspid valve with valvular insufficiency and right-left shunt].

    PubMed

    Delebarre, P; Augustin-Normand, C; Capronier, C; Cramer, J; Godeau, P; Letac, B; Forman, J; Maurice, P; Ourbak, P

    1987-05-01

    We present the case of a 50-year old man who progressively developed tricuspid valve insufficiency with opening of a patent foramen ovale responsible for right-to-left shunt with polycythaemia. The tricuspid valve insufficiency was due to a foreign body, probably of surgical origin as suggested by its radiological image and by the patient's previous history. It would have been introduced, far away from the tricuspid valve (compound fracture of the wrist), several years previously. At surgery, we found the foreign body embedded in the valve system. As a possible mechanism for the mutilation, an undiagnosed endocarditis was suspected but could not be confirmed. Three cases tricuspid endocarditis (with foreign bodies in the right ventricle) and 3 cases of asymptomatic tricuspid valve foreign bodies have been published. Fifty-five cases of foreign bodies introduced peripherally and migrated into the heart, the pericardium and the pulmonary artery are reviewed.

  8. [Plastic repair of tricuspid valve: Carpentier's ring annuloplasty versus De VEGA technique].

    PubMed

    Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir

    2017-01-01

    Tricuspid valve disease has been neglected for a long time by cardiologists and surgeons, but for some years now leakage of tricuspid valve has been demonstrated as a prognostic factor in the evolution of patients with left heart valve disease undergoing surgery. Several techniques for plastic repair of tricuspid valve have been developed and the published studies differ on the results of these techniques; we conducted this study to assess the results of plastic repair of tricuspid valve in a population of patients with a high prevalence of rheumatic disease and to compare Carpentier's ring annuloplasty techniques with DEVEGA plasty. We conducted a retrospective study of patients undergoing plastic repair of tricuspid valve in the Department of Cardiology at the Medicine University of Sfax over a period of 25 years. We compared the results from the Group 1 (Carpentier's ring annuloplasty) with Group 2 (DeVEGA plasty). 91 patients were included in our study, 45 patients in the Group 1 and 46 patients in the Group 2. Most patients had mean or severe TI (83%) before surgery, ring dilation was observed in 90% of patients with no significant difference between the two groups. Immediate results were comparable between the two techniques but during monitoring recurrent, at least mean, insufficiency was significantly more frequent in the DeVEGA plasty Group. The predictive factors for significant recurring long term TI were DeVEGA technique (OR=3.26[1.12-9.28]) in multivariate study and preoperative pulmonary artery systolic pressure (OR=1.06 (1.01-1.12)). Plastic repair of tricuspid valve using Carpentier's ring seems to guarantee better results than DeVEGA plasty. On the other hand, preoperative high PASP is predictive of recurrent leakage of tricuspid valve even after plasty; hence the importance of surgery in the treatment of patients at an early stage of the disease.

  9. [MitraClip® for treatment of tricuspid valve insufficiency].

    PubMed

    Pfister, R; Baldus, S

    2017-11-01

    Tricuspid valve regurgitation is frequently found as a result of right ventricular remodeling due to advanced left heart diseases. Drug treatment is limited to diuretics and the cardiac or pulmonary comorbidities. Due to the high risk only a small percentage of patients are amenable to surgical treatment of tricuspid regurgitation in those who undergo left-sided surgery for other reasons. Catheter-based procedures are an attractive treatment alternative, particularly since the strong prognostic impact of tricuspid regurgitation suggests an unmet need of treatment, independent of the underlying heart disease. A vast amount of clinical experience exists for the MitraClip system for treatment of mitral regurgitation. A first case series shows that the application for treatment of tricuspid regurgitation is technically feasible, seems to be safe and the degree of valve regurgitation can be reduced. In this review the background of tricuspid regurgitation treatment is summarized and first experiences and perspectives with the MitraClip system are assessed.

  10. Surgical access via right thoracotomy facilitates tricuspid valve surgery in sheep

    PubMed Central

    Bothe, Wolfgang; Diab, Mahmoud; Ostermann, Romanus; Schwarzer, Michael; Woelfel, Luisa; Bischoff, Sabine; Schubert, Harald

    2017-01-01

    In quadrupeds, the three-dimensional orientation of the heart with respect to the thorax is fundamentally different from that in humans. In this study, we assessed the best surgical approach to the tricuspid valve in sheep. Firstly, different surgical access sites to the tricuspid valve were tested in sheep cadavers, the anatomy was analyzed, and the optimal surgical approach to the tricuspid valve was determined. Secondly - along with cardiopulmonary bypass and cardioplegic arrest -the chosen approach was tested in six adult sheep in vivo. Anatomical analyses revealed that a left thoracotomy provided optimal access to the aorta and left heart. However, visualization of the right heart was significantly impaired. In contrast, a right thoracotomy provided good access to the right heart, but the ascending aorta was difficult to approach. Therefore, in the in vivo studies, arterial cannulation was performed through a carotid (n = 4) or femoral (n = 2) artery. In conclusion, a right-sided thoracotomy allows good visualization of all components of the tricuspid valve complex in sheep, but not of the ascending aorta. Consequently, peripheral vessels are preferred for arterial cannulation. This work may stimulate the investigation of pathomechanisms and/or novel treatment options for tricuspid valve pathologies. PMID:27456775

  11. Tricuspid Valve Repair in Infancy Using Neochordae: Three-Dimensional Echocardiographic Imaging.

    PubMed

    Martin, Billie-Jean; Khoo, Nee S; Smallhorn, Jeffrey; Aklabi, Mohammed Al

    2017-11-01

    Tricuspid regurgitation (TR) in infancy poses a surgical challenge. Both two- and three-dimensional echocardiography (3DE) can provide detailed information about the mechanism(s) of valve failure and insights into valve adaptation during follow-up. We report two patients who underwent tricuspid valve repair using Gore-Tex neochordae, repairs which were facilitated by and assessed with 3DE. Both infants had less than mild residual TR and no valve tethering at hospital discharge. Furthermore, follow-up 3DEs have helped to confirm valve competence, lack of tethering, and growth of the valve and valve apparatus.

  12. Permanent pacemaker lead induced severe tricuspid regurgitation in patient undergoing multiple valve surgery.

    PubMed

    Lee, Jung Hee; Kim, Tae Ho; Kim, Wook Sung

    2015-04-01

    Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.

  13. Tricuspid regurgitation after successful mitral valve surgery

    PubMed Central

    Katsi, Vasiliki; Raftopoulos, Leonidas; Aggeli, Constantina; Vlasseros, Ioannis; Felekos, Ioannis; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Kallikazaros, Ioannis

    2012-01-01

    The tricuspid valve (TV) is inseparably connected with the mitral valve (MV) in terms of function. Any pathophysiological condition concerning the MV is potentially a threat for the normal function of the TV as well. One of the most challenging cases is functional tricuspid regurgitation (TR) after surgical MV correction. In the past, TR was considered to progressively revert with time after left-sided valve restoration. Nevertheless, more recent studies showed that TR could develop and evolve postoperatively over time, as well as being closely associated with a poorer prognosis in terms of morbidity and mortality. Pressure and volume overload are usually the underlying pathophysiological mechanisms; structural alterations, like tricuspid annulus dilatation, increased leaflet tethering and right ventricular remodelling are almost always present when regurgitation develops. The most important risk factors associated with a higher probability of late TR development involve the elderly, female gender, larger left atrial size, atrial fibrillation, right chamber dilatation, higher pulmonary artery systolic pressures, longer times from the onset of MV disease to surgery, history of rheumatic heart disease, ischaemic heart disease and prosthetic valve malfunction. The time of TR manifestation can be up to 10 years or more after an MV surgery. Echocardiography, including the novel 3D Echo techniques, is crucial in the early diagnosis and prognosis of future TV disease development. Appropriate surgical technique and timing still need to be clarified. PMID:22457188

  14. Transapical tricuspid valve-in-ring implantation: An alternative approach to a challenging clinical scenario.

    PubMed

    Girdauskas, Evaldas; Lauer, Bernward; Kuntze, Thomas

    2018-04-01

    We report on a transapical tricuspid valve-in-ring implantation performed via right ventricular apex using the Sapien-XT-prosthesis. A 57-year-old woman with recurrent episodes of right heart failure and three previous sternotomies, including tricuspid valve repair with a 32 mm Carpentier-Edwards-Classic annuloplasty ring was admitted due to recurrent severe tricuspid regurgitation. Given the excessive surgical risk, a 29 mm Sapien-XT-prosthesis was selected for valve-in-ring implantation. Transapical valve-in-ring implantation procedure was uneventful. Predischarge echocardiography showed only trace paravalvular tricuspid regurgitation in the septal region. Transapical approach via right ventricular apex is a viable alternative for tricuspid valve-in-ring implantation in selected high-risk patients. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Tricuspid valve dysplasia with severe tricuspid regurgitation: fetal pulmonary artery size predicts lung viability in the presence of small lung volumes.

    PubMed

    Nathan, A T; Marino, B S; Dominguez, T; Tabbutt, S; Nicolson, S; Donaghue, D D; Spray, T L; Rychik, J

    2010-01-01

    Congenital tricuspid valve disease (Ebstein's anomaly, tricuspid valve dysplasia) with severe tricuspid regurgitation and cardiomegaly is associated with poor prognosis. Fetal echocardiography can accurately measure right atrial enlargement, which is associated with a poor prognosis in the fetus with tricuspid valve disease. Fetal lung volumetric assessments have been used in an attempt to predict viability of fetuses using ultrasonogram and prenatal MRI. We describe a fetus with tricuspid dysplasia, severe tricuspid regurgitation, right atrial enlargement and markedly reduced lung volumes. The early gestational onset of cardiomegaly with bilateral lung compression raised the possibility of severe lung hypoplasia with decreased broncho-alveolar development. Use of fetal echocardiography with measurement of pulmonary artery size combined with prenatal MRI scanning of lung volumes resulted in an improved understanding of this anomaly and directed the management strategy towards a successful Fontan circulation. 2010 S. Karger AG, Basel.

  16. Recurrent pulmonary embolism due to hydatid disease of heart. Study of 3 cases, one with intermittent tricuspid valve obstruction (atrial pseudomyxoma).

    PubMed Central

    Gilsanz, V; Campo, C; Cue, R; Estella, J; Estrada, R V; Perez-oteiza, C; Rabago, G; Rebollar, J L; Zarco, P

    1977-01-01

    Three cases of pulmonary hypertension caused by hydatid emboli from the right side of the heart are described; cardiac catheterisation was performed in 2. One case was confirmed at operation and 2 at necropsy. The pulmonary emboli were caused by hydatid vesicles in all 3 cases and in none was there pulmonary thrombosis; free scolices were found in the pulmonary alveoli in 2. In 1 patient with repeated syncopal attacks there was a pedunculated cyst in the right atrium which was though to have intermittently obstructed the tricuspid valve. Gamma radiography, angiocardiography, and necropsy suggested a mechanical cause for the pulmonary hypertenion with no vasoconstrictive element. The surgical patient was alive and well 18 months later. Images PMID:861098

  17. Dysfunction of an On-X Heart Valve by Pannus.

    PubMed

    Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria

    2016-09-01

    A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.

  18. [Dopplerography of the large hepatic veins in the diagnosis of tricuspid valve insufficiency].

    PubMed

    Korytnikov, K I; Martyniuk, A D; Pustovit, L K

    1991-01-01

    During pulse dopplerography of the large hepatic veins in patients with tricuspid valve failure, the differences in the shape of the spectrum of Doppler's frequencies were revealed as dependent on cardiac rhythm. In sinus rhythm, the curve of the systolic flow is recordable beneath the baseline, in atrial fibrillation, over the baseline. In scanning of the large hepatic veins in patients with tricuspid valve failure, the shape of the curves of the spectrum of Doppler's frequencies coincides with the shape of the curves of liver pulsation. Tricuspid valve failure in sinus rhythm leads to a decrease of the maximum velocity of the systolic flow in the hepatic veins. There is a close correlation between the maximum velocity of the systolic flow of tricuspid regurgitation and the maximum velocity of the systolic flow in the large hepatic veins. Pulse dopplerography of the large hepatic veins is a safe enough method of the diagnosis of tricuspid valve failure and can be used in difficult cases when analysing the tricuspid blood flow from standard projections.

  19. Transfemoral implantation of an Edwards SAPIEN valve in a tricuspid bioprosthesis without fluoroscopic landmarks.

    PubMed

    Calvert, Patrick A; Himbert, Dominique; Brochet, Eric; Radu, Costin; Iung, Bernard; Hvass, Ulrik; Darondel, Jean-Marc; Depoix, Jean-Pol; Nataf, Patrick; Vahanian, Alec

    2012-03-01

    We describe the first report of an Edwards SAPIEN valve implanted in a tricuspid bioprosthesis from the femoral vein. We highlight the feasibility of this previously avoided approach and the techniques involved. A 61-year-old woman with multiple valve replacements for rheumatic heart disease presented with NHYA IV dyspnoea secondary to a severely stenosed tricuspid bioprosthesis. After failed aggressive medical therapy and surgical turn down, an Edwards SAPIEN XT valve was deployed in the tricuspid bioprosthesis via the right femoral vein. Adaptations to the standard transfemoral transcatheter aortic valve implantation (TAVI) technique included: (1) crossing the tricuspid bioprosthesis with a balloon floatation catheter; (2) temporary pacing wire in the coronary sinus rather than the right ventricle; (3) mounting of the SAPIEN XT valve in the reverse orientation to transfemoral TAVI; and (4) fine positioning of the final valve position pre-deployment by 3D transoesophageal echocardiography (3D TOE) alone due to complete radiolucency of the tricuspid bioprosthesis. The procedure was completed without complication and resulted in significant symptomatic improvement. Deployment of an Edwards SAPIEN valve in a tricuspid bioprosthesis via the femoral vein is feasible and, with careful adaptations to established TAVI techniques, can be performed without complications and with good clinical response.

  20. Tricuspid regurgitation in mitral valve disease incidence, prognostic implications, mechanism, and management.

    PubMed

    Shiran, Avinoam; Sagie, Alex

    2009-02-03

    Tricuspid regurgitation (TR) in patients with mitral valve (MV) disease is associated with poor outcome and predicts poor survival, heart failure, and reduced functional capacity. It is common if left untreated after MV replacement mainly in rheumatic patients, but it is also common in patients with ischemic mitral regurgitation. It is less common, however, in those with degenerative mitral regurgitation. It might appear many years after surgery and might not resolve after correcting the MV lesion. Late TR might be caused by prosthetic valve dysfunction, left heart disease, right ventricular (RV) dysfunction and dilation, persistent pulmonary hypertension, chronic atrial fibrillation, or by organic (mainly rheumatic) tricuspid valve disease. Most commonly, late TR is functional and isolated, secondary to tricuspid annular dilation. Outcome of isolated tricuspid valve surgery is poor, because RV dysfunction has already occurred at that point in many patients. MV surgery or balloon valvotomy should be performed before RV dysfunction, severe TR, or advanced heart failure has occurred. Tricuspid annuloplasty with a ring should be performed at the initial MV surgery, and the tricuspid annulus diameter (>or=3.5 cm) is the best criterion for performing the annuloplasty. In this article we will review the current data available for understanding the prognostic implications, mechanism, and management of TR in patients with MV disease.

  1. Traumatic rupture of the tricuspid valve and multi-modality imaging

    PubMed Central

    Corneli, Mariana; Conde, Diego; Ronderos, Ricardo

    2014-01-01

    Introduction Motor vehicle accident (MVA) account for most cases of traumatic rupture of the tricuspid valve. Valve rupture during an MVA is generated by an abrupt deceleration coupled with an increase in right-side cardiac pressures (Valsalva maneuver and thorax compression). Case A 39-year-old asymptomatic man was referred for an echocardiogram due to the presence of a systolic murmur. He had no prior significant medical history, except for a remote MVA 3 years ago. Real-time 3D echocardiography (RT3DE) showed a tear in the body of the anterior leaflet and not at the cord, as was suggested by two-dimensional transthoracic echocardiography (2D-TTE). Based on these findings, the mechanism was considered anterior leaflet rupture of the tricuspid valve, secondary to chest blunt trauma. The anterior leaflet was repaired using two polytetrafluoroethylene sutures, and tricuspid annuloplasty with an Edwards ring was performed. Conclusions Multimodality imaging helps to determine timing of surgery in asymptomatic traumatic tricuspid rupture. The combination of echocardiography and magnetic resonance imaging provide information of volumetric data and contractility of the right ventricle (RV) during follow-up. RT3DE gives information relevant to the morphological and functional characterization of the valve, allowing the planning of appropriate surgical procedure. PMID:25414827

  2. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    PubMed

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. Traumatic Tricuspid Insufficiency Requiring Valve Repair in an Acute Setting.

    PubMed

    Enomoto, Yoshinori; Sudo, Yoshio; Sueta, Tomonori

    2015-01-01

    Tricuspid insufficiency due to penetrating cardiac trauma is rare. Patients with tricuspid insufficiency due to trauma can tolerate this abnormality for months or even years. We report a case of a 66-year-old female with penetrating cardiac trauma on the right side of her heart that required tricuspid valve repair in an acute setting. She sustained cut and stab wounds on her bilateral forearms and in the neck and epigastric region. She had cardiac tamponade and developed pulseless electrical activity, which required emergency surgery. The right ventricle and superior vena cava were dissected approximately 5 cm and 2 cm, respectively. After these wounds had been repaired, the patient's inability to wean from cardiopulmonary bypass suggested rightsided heart failure; transesophageal echocardiography revealed tricuspid insufficiency. Right atriotomy was performed, and a detailed examination revealed that the tricuspid valve septal leaflet was split in two. There was also an atrial septal injury that created a connection with the left atrium; these injuries were not detected from the right ventricular wound. After repair, weaning from cardiopulmonary bypass with mild tricuspid insufficiency was achieved, and she recovered uneventfully. This case emphasized the importance of thoroughly investigating intracardiac injury and transesophageal echocardiography.

  4. First percutaneous Micra leadless pacemaker implantation and tricuspid valve repair with MitraClip NT for lead-associated severe tricuspid regurgitation.

    PubMed

    Tang, Gilbert H L; Kaple, Ryan; Cohen, Martin; Dutta, Tanya; Undemir, Cenap; Ahmad, Hasan; Poniros, Angelica; Bennett, Joanne; Feng, Cheng; Lansman, Steven

    2017-02-03

    Pacemaker lead-associated severe tricuspid regurgitation (TR) can lead to right heart failure and poor prognosis. Surgery in these patients carries significant morbidities. We describe a successful treatment of symptomatic severe TR by leadless pacemaker implantation followed by tricuspid valve (TV) repair with the MitraClip NT. A 71-year-old frail female with poor functional status, chronic atrial fibrillation and permanent pacemaker implantation in 2012 presented with symptomatic moderate-severe mitral regurgitation (MR) and severe TR with the pacemaker lead as the culprit. She was deemed extreme risk for double valve surgery and, because of her pacemaker dependency, the decision was to stage her interventions first with transcatheter mitral repair, then laser lead extraction and leadless pacemaker implantation to free the TV from tethering, then TV repair. An obstructive LAD lesion was identified and treated during mitral repair with the MitraClip NT. The Micra leadless pacemaker implantation and subsequent TV repair with the MitraClip NT were successful and the patient's MR improved to mild and TR to moderate, respectively. We report here a first successful transcatheter strategy to treat lead-associated severe TR by leadless pacemaker and MitraClip. Removing the pacemaker lead relieved leaflet tethering and improved the reparability of the TV.

  5. Percutaneous pulmonary and tricuspid valve implantations: An update

    PubMed Central

    Wagner, Robert; Daehnert, Ingo; Lurz, Philipp

    2015-01-01

    The field of percutaneous valvular interventions is one of the most exciting and rapidly developing within interventional cardiology. Percutaneous procedures focusing on aortic and mitral valve replacement or interventional treatment as well as techniques of percutaneous pulmonary valve implantation have already reached worldwide clinical acceptance and routine interventional procedure status. Although techniques of percutaneous pulmonary valve implantation have been described just a decade ago, two stent-mounted complementary devices were successfully introduced and more than 3000 of these procedures have been performed worldwide. In contrast, percutaneous treatment of tricuspid valve dysfunction is still evolving on a much earlier level and has so far not reached routine interventional procedure status. Taking into account that an “interdisciplinary challenging”, heterogeneous population of patients previously treated by corrective, semi-corrective or palliative surgical procedures is growing inexorably, there is a rapidly increasing need of treatment options besides redo-surgery. Therefore, the review intends to reflect on clinical expansion of percutaneous pulmonary and tricuspid valve procedures, to update on current devices, to discuss indications and patient selection criteria, to report on clinical results and finally to consider future directions. PMID:25914786

  6. Surgical treatment of tricuspid regurgitation after mitral valve surgery: a retrospective study in China

    PubMed Central

    2012-01-01

    Background Functional tricuspid regurgitation (TR) occurs in patients with rheumatic mitral valve disease even after mitral valve surgery. The aim of this study was to analyze surgical results of TR after previous successful mitral valve surgery. Methods From September 1996 to September 2008, 45 patients with TR after previous mitral valve replacement underwent second operation for TR. In those, 43 patients (95.6%) had right heart failure symptoms (edema of lower extremities, ascites, hepatic congestion, etc.) and 40 patients (88.9%) had atrial fibrillation. Twenty-six patients (57.8%) were in New York Heart Association (NYHA) functional class III, and 19 (42.2%) in class IV. Previous operations included: 41 for mechanical mitral valve replacement (91.1%), 4 for bioprosthetic mitral valve replacement (8.9%), and 7 for tricuspid annuloplasty (15.6%). Results The tricuspid valves were repaired with Kay's (7 cases, 15.6%) or De Vega technique (4 cases, 8.9%). Tricuspid valve replacement was performed in 34 cases (75.6%). One patient (2.2%) died. Postoperative low cardiac output (LCO) occurred in 5 patients and treated successfully. Postoperative echocardiography showed obvious reduction of right atrium and ventricle. The anterioposterior diameter of the right ventricle decreased to 25.5 ± 7.1 mm from 33.7 ± 6.2 mm preoperatively (P < 0. 05). Conclusion TR after mitral valve replacement in rheumatic heart disease is a serious clinical problem. If it occurs or progresses late after mitral valve surgery, tricuspid valve annuloplasty or replacement may be performed with satisfactory results. Due to the serious consequence of untreated TR, aggressive treatment of existing TR during mitral valve surgery is recommended. PMID:22490269

  7. Flail anterior tricuspid valve leaflet in a neonate: association with maternal antiphospholipid syndrome.

    PubMed

    Tarca, Adrian J; Eckersley, Luke; Kothari, Darshan

    2017-10-01

    This brief report describes a case of flail anterior tricuspid valve leaflet in a neonate associated with maternal antiphospholipid syndrome. Fetal echocardiography at 27 weeks of gestation showed competent atrioventricular valves with biventricular echogenic chordae. Fetal distress was noted at delivery, and echocardiography showed a flail anterior leaflet of the tricuspid valve with severe regurgitation. Possible causation and implications of maternal antiphospholipid syndrome are discussed.

  8. Aortic valve replacement and tricuspid valve annuloplasty via a left thoracotomy in an adult with left pulmonary agenesis.

    PubMed

    Furutachi, Akira; Furukawa, Kojiro; Shimauchi, Kouta; Yunoki, Junji; Itoh, Manabu; Takamatsu, Masanori; Nogami, Eijiro; Mukae, Yosuke; Nishida, Takahiro

    2018-06-06

    We report a case of a 66-year-old man who was diagnosed with severe aortic regurgitation, moderate tricuspid regurgitation and chronic atrial fibrillation. Preoperative computed tomography showed left lung agenesis. We performed aortic valve replacement, tricuspid valve annuloplasty and right pulmonary vein isolation via a left thoracotomy. This approach provided an adequate field of view.

  9. [Functional tricuspid regurgitation and its relation to the morphology of the tricuspid valve and annulus: pulsed doppler echocardiography and two-dimensional echocardiography].

    PubMed

    Mikami, T; Kudo, T; Sakurai, N; Sakamoto, S; Tanabe, Y; Yasuda, H

    1983-06-01

    The mechanism for the development of functional tricuspid regurgitation (TR) was studied by an ultrasonic method. Thirty-five examinations were performed in 31 patients who were expected to have functional TR, and the severity was classified into 4 grades according to the extension of the regurgitant signals by pulsed Doppler echocardiography. The satisfactory horizontal section of the tricuspid valve was obtained by two-dimensional echocardiography (2DE) to measure the tricuspid annular diameter and to observe systolic configuration of the tricuspid valve in 22 examinations. The tricuspid annular diameter was well correlated with the severity of TR, and "lack of coaptation" of the valve was recognized on 2DE in some cases of severe TR with the markedly dilated annulus, indicating that this dilatation was an important trigger of functional TR. Additionally, in the majority of patients with severe TR, "anterior displacement" of the tips of tricuspid leaflet(s) (6 mm or more from the tricuspid annulus towards the right ventricle) was observed, which was thought to be due to the chordal traction secondary to the right ventricular dilatation, and contributed to the development of functional TR by disturbing sufficient coaptation. In one particular case, severe TR was associated with " malaligned coaptation" caused by the anterior displacement confined to the septal leaflet, indicating that asymmetrical dilatation of the right ventricle and/or disorientation of chordae-valve system may contribute to TR.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Isolated Tricuspid Valve Libman-Sacks Endocarditis in Systemic Lupus Erythematosus with Secondary Antiphospholipid Syndrome.

    PubMed

    Unic, Daniel; Planinc, Mislav; Baric, Davor; Rudez, Igor; Blazekovic, Robert; Senjug, Petar; Sutlic, Zeljko

    2017-04-01

    Libman-Sacks endocarditis, one of the most prevalent cardiac presentations of systemic lupus erythematosus, typically affects the aortic or mitral valve; tricuspid valve involvement is highly unusual. Secondary antiphospholipid syndrome increases the frequency and severity of cardiac valvular disease in systemic lupus erythematosus. We present the case of a 47-year-old woman with lupus and antiphospholipid syndrome whose massive tricuspid regurgitation was caused by Libman-Sacks endocarditis isolated to the tricuspid valve. In addition, we discuss this rare case in the context of the relevant medical literature.

  11. Latent Tricuspid Valve Rupture after Motor Vehicle Accident and Routine Echocardiography in All Chest-Wall Traumas

    PubMed Central

    Khurana, Suchi; Puri, Rishi; Wong, Dennis; Dundon, Benjamin K.; Brown, Michael A.; Worthley, Matthew I.; Worthley, Stephen G.

    2009-01-01

    Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis. Herein, we report the case of a 42-year-old woman who sustained substantial chest-wall trauma in a high-speed motor vehicle accident. She presented a week later with symptoms of right-heart failure, secondary to flail tricuspid valve leaflets and torrential tricuspid regurgitation. The case of this patient highlights the importance of early diagnosis and elicits discussion of the mechanisms that can underlie delayed tricuspid valve rupture. Because the clinical diagnosis of tricuspid valve rupture can be difficult, we believe that echocardiography should be used early and, if necessary, repeatedly in all patients who sustain blunt chest-wall trauma. PMID:20069094

  12. Direct imaging of the tricuspid valve annular motions by fiberoptic cardioscopy in dogs. I. Does De Vega's annuloplasty preserve the annular motions?

    PubMed

    Minato, N; Itoh, T

    1992-12-01

    Applying the technology of direct imaging by fiberoptic cardioscopy, physiologic and pathophysiologic motions of the tricuspid valve anulus were studied in 10 anesthetized normal dogs (control group) and in 9 dogs that had chronic tricuspid regurgitation (TR group). The heart was perfused with transparent modified Tyrode's solution by working heart method, and the anuli, outlined by sutured beads, were observed and recorded on a high-speed video system in real time. Tricuspid valve annular area was calculated at 14 points during the cardiac cycle. The control group was studied in the normal condition, and the tricuspid regurgitation group was studied during four interventions: nontricuspid annuloplasty group and three tricuspid annuloplasty groups with reducing tricuspid valve annular area to 80%, 65%, and 50% of that of the non-tricuspid annuloplasty group by De Vega's procedure. Tricuspid valve annular area in the control group increased by 7% during atrial systole and was reduced by 34% mainly during ventricular systole, in which the free wall annular area and the septal annular area narrowed by an equal 34%. Chronic tricuspid regurgitation lessened tricuspid valve annular area narrowing to 20% in percent reduction (p < 0.01). In the TR group the decrease in tricuspid valve annular area narrowing was attributed mainly to lessened narrowing of the free wall anulus (percent reduction of tricuspid valve annular area, 19%; p < 0.01). The amplitudes in tricuspid valve annular area narrowing were unchanged in the tricuspid annuloplasty groups even when tricuspid valve annular area, was reduced to 50% by De Vega's tricuspid annuloplasty (percent reduction of tricuspid valve annular area, 16%; not significant). These findings suggest that De Vega's tricuspid annuloplasty is a reasonable method that does preserve the physiologic annular motions in the opening and closing mechanism of the tricuspid valve.

  13. Tricuspid valve regurgitation after heart transplantation.

    PubMed

    Kwon, Murray H; Shemin, Richard J

    2017-05-01

    Tricuspid valve regurgitation (TVR) in the orthotopic heart transplant (OHT) recipient is quite common and has varied clinical sequelae. In its severest forms, it can lead to right-sided failure symptoms indistinguishable from that seen in native heart TVR disease. While certain implantation techniques are widely recognized to reduce the risk of TVR in the cardiac allograft, concomitant tricuspid annuloplasty, while having advocates, is not currently accepted as a routinely established adjunct. Decisions to surgically correct TVR in the OHT recipient must be made carefully, as certain clinical scenarios have high risk of failure. Like in the native heart, anatomic etiologies typically have the greatest chances for success compared to functional etiologies. While repair options have been utilized, there is emerging data to support replacement as the more durable option. While mechanical prostheses are impractical in the heart transplant recipient, biologic valves offer the advantage of continued access to the right ventricle for biopsies in addition to acceptable durability in the low pressure system of the right side.

  14. Percutaneous Tricuspid Valve Regurgitation Repair With the MitraClip Device Using an Edge-to-Edge Bicuspidization Technique.

    PubMed

    Gafoor, Sameer; Petrescu, O Madalina; Lehr, Eric J; Puls, Charles; Zhang, Ming; Petersen, John L; Olsen, John V; Penev, Irina; Agrawal, Mayank; Sharma, Rahul; Barnhart, Glenn

    2017-03-01

    Patients who present with both severe mitral and tricuspid regurgitation who are symptomatic despite optimal medical therapy and at prohibitive risk for surgery pose a significant therapeutic challenge. The MitraClip device (Abbott Vascular) is approved for percutaneous mitral valve repair in high-risk and non-operative patients, and has also been used for tricuspid valve repair. Imaging support for percutaneous edge-to-edge tricuspid valve repair has not been reported and is a vital part of the procedure. Here, we present a periprocedural imaging strategy for percutaneous tricuspid valve repair with the MitraClip device using a bicuspidization technique.

  15. Should Tricuspid Annuloplasty be Performed With Pulmonary Valve Replacement for Pulmonary Regurgitation in Repaired Tetralogy of Fallot?

    PubMed

    Kurkluoglu, Mustafa; John, Anitha S; Cross, Russell; Chung, David; Yerebakan, Can; Zurakowski, David; Jonas, Richard A; Sinha, Pranava

    2015-01-01

    Indications for prophylactic tricuspid annuloplasty in patients with pulmonary regurgitation (PR) after tetralogy of Fallot (TOF) repair are unclear and often extrapolated from acquired functional tricuspid regurgitation (TR) data in adults, where despite correction of primary left heart pathology, progressive tricuspid annular dilation is noted beyond a threshold diameter >4 cm (21 mm/m(2)). We hypothesized that unlike in adult functional TR, in pure volume-overload conditions such as patients with PR after TOF, the tricuspid valve size is likely to regress after pulmonary valve replacement (PVR). A total of 43 consecutive patients who underwent PVR from 2005 until 2012 at a single institution were retrospectively reviewed. Absolute and indexed tricuspid annulus diameters (TADs), tricuspid annulus Z-scores, grade of TR along with right ventricular size, and function indices were recorded before and after PVR. Preoperative and postoperative echocardiographic data were available in all patients. A higher tricuspid valve Z-score correlated with greater TR both preoperatively (P = 0.005) and postoperatively (P = 0.02). Overall reductions in the absolute and indexed TAD and tricuspid valve Z-scores were seen postoperatively, with greater absolute as well as percentage reduction seen with larger preoperative TAD index (P = 0.007) and higher tricuspid annulus Z-scores (P = 0.06). In pure volume-overload conditions such as patients with PR after TOF, reduction in the tricuspid valve size is seen after PVR. Concomitant tricuspid annuloplasty should not be considered based on tricuspid annular dilation alone. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Mechanism of tricuspid regurgitation in paramembranous ventricular septal defect.

    PubMed

    Hagler, Donald J; Squarcia, Umberto; Cabalka, Allison K; Connolly, Heidi M; O'Leary, Patrick W

    2002-04-01

    Literature has been limited in regard to the mechanisms of tricuspid regurgitation (TR) in patients with paramembranous (perimembranous) ventricular septal defect (VSD). Most observations have noted tricuspid valve clefts or dysplasia. We describe another mechanism for production of TR in association with paramembranous VSD. In 8 patients, we found significant TR produced by the VSD jet pushing the tricuspid anterior leaflet forward to open the tricuspid valve orifice. In these patients, a moderate paramembranous VSD extended slightly below the septal tricuspid leaflet with only partial obstruction of the VSD jet. All patients had restrictive VSD with low right ventricular pressure. This mechanism to produce TR was best defined by intraoperative transesophageal echocardiography, but current higher resolution imaging should allow correct diagnosis. We believe that when this mechanism for TR is found in association with a moderate VSD, surgical VSD closure is warranted.

  17. Advances in percutaneous interventional therapies: the tricuspid valve.

    PubMed

    Jabbour, Richard J; Giannini, Francesco; Tanaka, Akihito; Mangieri, Antonio; Mikhail, Ghada W; Latib, Azeem; Colombo, Antonio

    2017-05-01

    Tricuspid regurgitation (TR) is a prevalent valve condition, with an estimated 1.6 million people in the USA living with moderate or greater severity. Functional TR, which predominantly develops due to left-sided heart disease, is the predominant condition affecting the tricuspid valve in the Western world and severe TR is associated with substantial morbidity and mortality. In part, due to a prolonged latency period with insidious symptoms, patients are often referred for surgery at advanced stages, with associated increased or prohibitive surgical risk. In addition, surgical treatment can result in high rates of recurrence. Therefore, there is an unmet need for percutaneous therapies that may provide a relatively low-risk treatment option. There are several devices with early human feasibility data available that will be reviewed in this article.

  18. Flail Tricuspid Valve in an Adult Patient with Congenitally Corrected Transposition of the Great Arteries.

    PubMed

    Meloni, Luigi; Abbruzzese, Piero A.; Pirisi, Raimondo; Cherchi, Angelo

    1997-01-01

    We describe a case of a 50-year-old woman with congenitally corrected transposition of the great vessels, in whom severe left-sided tricuspid (systemic atrioventricular) valve insufficiency was the only associated anomaly. The tricuspid valve was dysplastic and abnormally oriented toward the interventricular septum, without the downward displacement of Ebstein's anomaly. The mechanism of atrioventricular regurgitation was unusual in that it consisted of the rupture of chordae tendineae of both the anterior and septal leaflets. The left-sided tricuspid valve was replaced with a St. Jude prosthesis and the postoperative course was uneventful.

  19. Recurrent protein-losing enteropathy and tricuspid valve insufficiency in a transplanted heart: a causal relationship?

    PubMed

    Aggarwal, Sanjeev; Delius, Ralph E; Walters, Henry L; L'Ecuyer, Thomas J

    2012-01-01

    This case report describes a toddler who developed a protein-losing enteropathy (PLE) 4 years after orthotopic heart transplantation (OHT). He was born with a hypoplastic left heart syndrome for which he underwent a successful Norwood procedure, a Hemi-Fontan palliation, and a Fontan palliation at 18 months of age. Fifteen months following the Fontan operation, he developed a PLE and Fontan failure requiring OHT. Four years after OHT, he developed a severe tricuspid regurgitation and a PLE. His PLE improved after tricuspid valve replacement. It is now 2 years since his tricuspid valve replacement and he remains clinically free of ascites and peripheral edema with a normal serum albumin level. His prosthetic tricuspid valve is functioning normally. © 2011 Wiley Periodicals, Inc.

  20. On the bending properties of porcine mitral, tricuspid, aortic, and pulmonary valve leaflets.

    PubMed

    Brazile, Bryn; Wang, Bo; Wang, Guangjun; Bertucci, Robbin; Prabhu, Raj; Patnaik, Sourav S; Butler, J Ryan; Claude, Andrew; Brinkman-Ferguson, Erin; Williams, Lakiesha N; Liao, Jun

    2015-01-01

    The atrioventricular valve leaflets (mitral and tricuspid) are different from the semilunar valve leaflets (aortic and pulmonary) in layered structure, ultrastructural constitution and organization, and leaflet thickness. These differences warrant a comparative look at the bending properties of the four types of leaflets. We found that the moment-curvature relationships in atrioventricular valves were stiffer than in semilunar valves, and the moment-curvature relationships of the left-side valve leaflets were stiffer than their morphological analog of the right side. These trends were supported by the moment-curvature curves and the flexural rigidity analysis (EI value decreased from mitral, tricuspid, aortic, to pulmonary leaflets). However, after taking away the geometric effect (moment of inertia I), the instantaneous effective bending modulus E showed a reversed trend. The overall trend of flexural rigidity (EI: mitral > tricuspid > aortic > pulmonary) might be correlated with the thickness variations among the four types of leaflets (thickness: mitral > tricuspid > aortic > pulmonary). The overall trend of the instantaneous effective bending modulus (E: mitral < tricuspid < aortic < pulmonary) might be correlated to the layered fibrous ultrastructures of the four types of leaflets, of which the fibers in mitral and tricuspid leaflets were less aligned, and the fibers in aortic and pulmonary leaflets were highly aligned. We also found that, for all types of leaflets, moment-curvature relationships are stiffer in against-curvature (AC) bending than in with-curvature bending (WC), which implies that leaflets tend to flex toward their natural curvature and comply with blood flow. Lastly, we observed that the leaflets were stiffer in circumferential bending compared with radial bending, likely reflecting the physiological motion of the leaflets, i.e., more bending moment and movement were experienced in radial direction than circumferential direction.

  1. Right heart chamber geometry and tricuspid annulus morphology in patients undergoing mitral valve repair with and without tricuspid valve annuloplasty.

    PubMed

    Tamborini, Gloria; Fusini, Laura; Muratori, Manuela; Gripari, Paola; Ghulam Ali, Sarah; Fiorentini, Cesare; Pepi, Mauro

    2016-06-01

    According to current recommendations, patients could benefit from tricuspid valve (TV) annuloplasty at the time mitral valve (MV) surgery if tricuspid regurgitation is severe or if tricuspid annulus (TA) dilatation is present. Therefore, an accurate pre-operative echocardiographic study is mandatory for left but also for right cardiac structures. Aims of this study are to assess right atrial (RA), right ventricular (RV) and TA geometry and function in patients undergoing MV repair without or with TV annuloplasty. We studied 103 patients undergoing MV surgery without (G1: 54 cases) or with (G2: 49 cases) concomitant TV annuloplasty and 40 healthy subjects (NL) as controls. RA, RV and TA were evaluated by three-dimensional (3D) transthoracic echocardiography. Comparing the pathological to the NL group, TA parameters and 3D right chamber volumes were significantly larger. RA and RV ejection fraction and TA% reduction were lower in pathological versus NL, and in G2 versus G1. In pathological patients, TA area positively correlated to systolic pulmonary pressure and negatively with RV and RA ejection fraction. Patients undergoing MV surgery and TV annuloplasty had an increased TA dimensions and a more advanced remodeling of right heart chambers probably reflecting an advanced stage of the disease.

  2. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    PubMed

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation.

    PubMed

    Chang, James D; Manning, Warren J; Ebrille, Elisa; Zimetbaum, Peter J

    2017-05-09

    The potential for cardiac implantable electronic device leads to interfere with tricuspid valve (TV) function has gained increasing recognition as having hemodynamic and clinical consequences associated with incremental morbidity and death. The diagnosis and treatment of lead-related (as distinct from functional) tricuspid regurgitation pose unique challenges. Because of pitfalls in routine diagnostic imaging, a high level of clinical suspicion must be maintained to avoid overlooking the possibility that worsening heart failure is a consequence of mechanical interference with TV leaflet mobility or coaptation and is amenable to lead extraction or valve repair or replacement. The future of cardiac implantable electronic devices includes pacing and perhaps defibrillation without a lead traversing the TV. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Traumatic Tricuspid Regurgitation.

    PubMed

    Cheng, Yan; Yao, Lei; Wu, Shengjun

    2017-05-31

    Traumatic tricuspid regurgitation is a rare and progressive disease. Early diagnosis and surgical valve repair are very important. A 57-year-old male was referred to our hospital with a history of blunt chest trauma. Three-dimensional echocardiography showed severe tricuspid regurgitation and demonstrated two main anterior leaflet chordaes of the tricuspid valve rupture and the whole anterior leaflet prolapsed. The diagnosis was severe tricuspid regurgitation due to leaflet chordae rupture secondary to blunt chest trauma. Surgical repair of the tricuspid valve was performed in this patient. At 3-month follow-up, the right ventricle was decreased in size with significantly improved right ventricular function. The signs and symptoms of right heart failure were relieved. In this case, 3-dimensional transthoracic echocardiography enabled fast and non-invasive evaluation of the spatial destruction of the tricuspid valve and subvalvular apparatus to assist in the planning of valve repair.

  5. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    PubMed

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P < .001), worse right ventricular dysfunction (right ventricular end-diastolic area, 33.6 ± 6.2 mm vs 31.6 ± 8.5 mm; P = .05), higher mean right atrial pressure (17.4 ± 7.1 mm Hg vs 14.9 ± 5.1 mm Hg; P = .03), and a higher Kormos score (2.6 ± 2.1 vs 1.2 ± 1.4; P = .0008) preoperatively. One month after surgery, tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device

  6. Presystolic tricuspid valve closure: an alternative mechanism of diastolic sound genesis.

    PubMed

    Lee, C H; Xiao, H B; Gibson, D G

    1990-01-01

    We describe a previously unrecognised cause of an added diastolic heart sound. The patient had first-degree heart block and diastolic tricuspid regurgitation, leading to presystolic closure of the tricuspid valve and the production of a loud diastolic sound. Unlike previously described mechanisms for diastolic sounds, this sound was generated by the sudden acceleration of retrograde AV flow in late diastole.

  7. Tricuspid valve dysplasia: A retrospective study of clinical features and outcome in dogs in the UK

    PubMed Central

    Navarro-Cubas, Xavier; Palermo, Valentina; French, Anne; Sanchis-Mora, Sandra; Culshaw, Geoff

    2017-01-01

    The objective of this study was to determine the demographic, clinical and survival characteristics and to identify risk factors for mortality due to tricuspid valve dysplasia in UK dogs. Records of client-owned dogs diagnosed with tricuspid valve dysplasia at a referral centre were retrospectively reviewed. Only dogs diagnosed with tricuspid valve dysplasia based on the presence of a right-sided heart murmur identified prior to one year of age, and confirmed with Doppler echocardiography, were included. Dogs with concomitant cardiac diseases, pulmonary hypertension and/or trivial tricuspid regurgitation were excluded. Analysed data included signalment, reason for presentation, clinical signs, electrocardiographic and echocardiographic features, survival status and cause of death. Survival times and risk factors for mortality were evaluated using Kaplan-Meier curves and Cox regression. Eighteen dogs met inclusion criteria. Border collies were over-represented (p= 0.014). Dogs were most frequently referred for investigation of heart murmur. The most common arrhythmia was atrial fibrillation (n=3). Median survival time from diagnosis of tricuspid valve dysplasia was 2775 days (range 1-3696 days; 95% CI 1542.41-4007.59) and from onset of right-sided congestive heart failure was 181 days (range 1-2130 days; 95% CI 0-455.59). Syncope was the sole risk factor for cardiac death. In this population of UK dogs, tricuspid valve dysplasia was uncommon but, when severe, frequently led to right-sided congestive heart failure. Prognosis was favourable for mild and moderate tricuspid dysplasia. Survival time was reduced with right-sided congestive heart failure but varied widely. Risk of cardiac death was significantly increased if syncope had occurred. PMID:29296595

  8. Role of tricuspid valve repair for moderate tricuspid regurgitation during minimally invasive mitral valve surgery.

    PubMed

    Pfannmueller, Bettina; Verevkin, Alexander; Borger, Michael Andrew; Mende, Meinhard; Davierwala, Piroze; Garbade, Jens; Mohr, Friedrich Wilhelm; Misfeld, Martin

    2013-08-01

    The aim of this study was to investigate the impact of short- and mid-term survival of tricuspid valve (TV) repair versus conservative therapy in patients with preoperative moderate functional tricuspid regurgitation (TR) undergoing minimally invasive mitral valve (MV) surgery. Between January 2002 and December 2009, a total of 430 patients with pure mitral regurgitation and concomitant moderate TR underwent minimally invasive MV surgery for mitral regurgitation at the Leipzig Heart Center without (n = 336; group A) and with (n = 94; group B) TV surgery. Mean age was 66.7 ± 10.3 years, mean LVEF was 58.0 ± 13.8%, and 206 patients (47.9%) were male. Average logEuroSCORE was 12.4 ± 11.4%. Follow-up was on average 4.6 ± 2.4 years and 97% completed. Predischarge echocardiography showed no or mild TR in 51.1% of patients in group A versus 84.2% of patients in group B (p < 0.01). Overall 30-day mortality was 2.8% with no differences between both groups. Five-year survival was 82.9 ± 4.1% for patients with TV repair versus 85.0 ± 2.2% for patients without TV repair (p = 0.1) and it was 85.7 ± 3.3% in patients with moderate and more postoperative TR versus 90.1 ± 2.5% in patients with less than moderate postoperative TR (p = 0.08). Five-year freedom from TV-related reoperation was 98.8 ± 0.7% for patients in group A versus 98.9 ± 0.1% for patients in group B (p = 0.8). Patients undergoing MV surgery with moderate functional TR do not experience increased perioperative complication rates when a concomitant TV repair is performed. Our observations, combined with those of other groups, support current recommendations to perform concomitant TV repair in such patients, particularly if tricuspid annular dilation is present. Georg Thieme Verlag KG Stuttgart · New York.

  9. Outcomes of ring versus suture annuloplasty for tricuspid valve repair in patients undergoing mitral valve surgery.

    PubMed

    Shinn, Sung Ho; Dayan, Victor; Schaff, Hartzell V; Dearani, Joseph A; Joyce, Lyle D; Lahr, Brian; Greason, Kevin L; Stulak, John M; Daly, Richard C

    2016-08-01

    There is controversy regarding the comparative effectiveness of methods of tricuspid valve (TV) repair-prosthetic ring versus suture annuloplasty-in patients undergoing operation for primary mitral valve (MV) disease. In this study, we analyzed factors associated with patient survival and recurrent tricuspid regurgitation (TR) following TV repair and focused on results stratified by method of tricuspid valve repair. We reviewed patients who underwent TV repair with suture (De Vega) or flexible ring annuloplasties at the time of MV surgery from 1995 to 2010. Patients with prior cardiac or concomitant aortic valve operations were excluded. Propensity matching was performed to account for potential differences in baseline characteristics between the groups. Primary outcomes were long-term mortality and postoperative TR grade. In the overall study, there were 415 patients with median age 72 years (range, 63-78 years), from which 148 matched pairs were identified by propensity score analysis. In the overall cohort, patients in the ring annuloplasty group more often had preoperative transvenous pacemakers (P = .05), lower ejection fractions (P = .028), and more recent years of operation (P < .001). For patients who had De Vega suture annuloplasty, long-term mortality was not different from that of patients who had ring annuloplasty (hazard ratio, 0.93; 95% confidence interval, 0.67-1.30). Older age, preoperative diabetes, and preoperative right ventricular dysfunction were predictors for long-term mortality. Durability of the annuloplasty methods was similar with no significant difference in trend of recurrent TR grades over follow-up (P = .807). Etiology of mitral regurgitation was not associated with recurrent TR during follow-up (P = .857). Late survival and TV durability following concomitant TV repair during MV surgery did not differ with respect to TV repair technique. In this series of patients with repaired tricuspid valves, etiology of MV disease did

  10. Surgical experience with diseases of the tricuspid valve. Cross-sectional and Doppler echocardiographic evaluation following DeVega's repair.

    PubMed

    Kulshrestha, P; Das, B; Iyer, K S; Sampathkumar, A; Sharma, M L; Rao, I M; Kaul, U; Srivastava, S; Bhatia, M L; Venugopal, P

    1989-04-01

    Seventy-eight patients undergoing mitral valve surgery with or without replacement of the aortic valve also underwent procedures on the tricuspid valve over a period of 10 years. All patients were in functional class III or IV preoperatively. The procedures were performed in all patients with organic disease of the tricuspid valve (N = 44) and in those with moderate or severe functional tricuspid valvar regurgitation (N = 34). Seventy-one patients underwent DeVega's annuloplasty with or without commissurotomy. The overall mortality was 11.5%. 65 long-term survivors were followed up for a period of 6 months to 10 years (mean 5.3 years). Sixty-three patients were in functional class I or II at the last follow-up. Six patients had clinical evidence of mild to moderate tricuspid regurgitation. Regression of cardiomegaly (as judged by the chest radiograph and right ventricular hypertrophy seen in the electrocardiogram) was evident in most cases. Fifty-one of 54 patients evaluated by cross-sectional echocardiography were reported to have a functionally normal tricuspid valve. Doppler echocardiography in 28 patients showed no significant tricuspid regurgitation or stenosis in 26 patients. Eleven consecutive patients undergoing DeVega's annuloplasty were studied prospectively with pre- and postoperative Doppler echocardiography. Good correlation existed between right ventricular systolic pressures predicted by Doppler with those obtained preoperatively at cardiac catheterization. Postoperative Doppler echocardiography in these 11 patients showed complete restoration of competence of the tricuspid valve as well as normalisation of the right ventricular systolic pressure in 10 patients.

  11. Repair or Replacement for Isolated Tricuspid Valve Pathology? Insights from a Surgical Analysis on Long-Term Survival

    PubMed Central

    Farag, Mina; Arif, Rawa; Sabashnikov, Anton; Zeriouh, Mohamed; Popov, Aron-Frederik; Ruhparwar, Arjang; Schmack, Bastian; Dohmen, Pascal M.; Szabó, Gábor; Karck, Matthias; Weymann, Alexander

    2017-01-01

    Background Long-term follow-up data concerning isolated tricuspid valve pathology after replacement or reconstruction is limited. Current American Heart Association guidelines equally recommend repair and replacement when surgical intervention is indicated. Our aim was to investigate and compare operative mortality and long-term survival in patients undergoing isolated tricuspid valve repair surgery versus replacement. Material/Methods Between 1995 and 2011, 109 consecutive patients underwent surgical correction of tricuspid valve pathology at our institution for varying structural pathologies. A total of 41 (37.6%) patients underwent tricuspid annuloplasty/repair (TAP) with or without ring implantation, while 68 (62.3%) patients received tricuspid valve replacement (TVR) of whom 36 (53%) were mechanical and 32 (47%) were biological prostheses. Results Early survival at 30 days after surgery was 97.6% in the TAP group and 91.1% in the TVR group. After 6 months, 89.1% in the TAP group and 87.8% in the TVR group were alive. In terms of long-term survival, there was no further mortality observed after one year post surgery in both groups (Log Rank p=0.919, Breslow p=0.834, Tarone-Ware p=0.880) in the Kaplan-Meier Survival analysis. The 1-, 5-, and 8-year survival rates were 85.8% for TAP and 87.8% for TVR group. Conclusions Surgical repair of the tricuspid valve does not show survival benefit when compared to replacement. Hence valve replacement should be considered generously in patients with reasonable suspicion that regurgitation after repair will reoccur. PMID:28236633

  12. The role of annular dimension and annuloplasty in tricuspid aortic valve repair.

    PubMed

    de Kerchove, Laurent; Mastrobuoni, Stefano; Boodhwani, Munir; Astarci, Parla; Rubay, Jean; Poncelet, Alain; Vanoverschelde, Jean-Louis; Noirhomme, Philippe; El Khoury, Gebrine

    2016-02-01

    Valve sparing reimplantation can improve the durability of bicuspid aortic valve repair compared with subcommissural annuloplasty, especially in patients with a large basal ring. This study analyses the effect of basal ring size and annuloplasty on valve repair in the setting of a tricuspid aortic valve. From 1995 to 2013, 382 patients underwent elective tricuspid aortic valve repair. We included only those undergoing subcommissural annuloplasty, valve sparing reimplantation or no annuloplasty and in whom intraoperative transoesophageal echocardiography images were available for retrospective pre- and post-repair basal ring measurements (n = 323, subcommissural annuloplasty: 146, valve sparing reimplantation: 154, no annuloplasty: 23). In a subgroup of patients with available echocardiographic images, basal ring was retrospectively measured at the latest follow-up or prior to reoperation. subcommissural annuloplasty and valve sparing reimplantation were compared after matching for degree of aortic regurgitation and root size. All three groups differed significantly for most of preoperative characteristics. Hospital mortality was 0.9%. The median follow-up was 4.7 years. At 8 years, overall survival was 80 ± 5%. Freedom from reoperation and freedom from aortic regurgitation >1+ were 92 ± 5% and 71 ± 8%, respectively. In multivariate analysis, predictors of aortic regurgitation >1+ were left ventricular end-diastolic diameter (P = 0.003), cusp repair (P = 0.006), body surface area (P = 0.01) and subcommissural annuloplasty (P = 0.05). In subcommissural annuloplasty, freedom from aortic regurgitation >1+ was lower for patients with basal ring ≥28 mm compared with patients with basal ring <28 mm (P = 0.0001). In valve sparing reimplantation, freedom from aortic regurgitation >1+ was independent of basal ring size (P = 0.38). In matched comparison between subcommissural annuloplasty and valve sparing reimplantation, freedom from aortic regurgitation >1+ was not

  13. Tricuspid atresia

    MedlinePlus

    Tri atresia; Valve disorder - tricuspid atresia; Congenital heart - tricuspid atresia; Cyanotic heart disease - tricuspid atresia ... Tricuspid atresia is an uncommon form of congenital heart disease. It affects about 5 in every 100, ...

  14. Tricuspid valve endocarditis

    PubMed Central

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  15. Partial rupture of the tricuspid valve after extraction of permanent pacemaker leads: detection by transesophageal echocardiography.

    PubMed

    Assayag, P; Thuaire, C; Benamer, H; Sebbah, J; Leport, C; Brochet, E

    1999-06-01

    Traumatic lesions of the tricuspid valve complicating pacemaker lead extractions appear to be rare. We report two cases of partial rupture of the tricuspid valve, following apparently uneventful extraction of permanent ventricular leads, resulting in severe regurgitation and, in one case, chronic heart failure. TEE was useful to identify the traumatic mechanism of tricuspid regurgitation (TR) and the extent of valvular lesions in these patients. Such etiology should be suspected, and TEE performed, in patients developing TR or heart failure late after lead extraction.

  16. Minimally Invasive Implantation of HeartWare Assist Device and Simultaneous Tricuspid Valve Reconstruction Through Partial Upper Sternotomy.

    PubMed

    Hillebrand, Julia; Hoffmeier, Andreas; Djie Tiong Tjan, Tonny; Sindermann, Juergen R; Schmidt, Christoph; Martens, Sven; Scherer, Mirela

    2017-05-01

    Left ventricular assist device (LVAD) implantation is a well-established therapy to support patients with end-stage heart failure. However, the operative procedure is associated with severe trauma. Third generation LVADs like the HeartWare assist device (HeartWare, Inc., Framingham, MA, USA) are characterized by enhanced technology despite smaller size. These devices offer new minimally invasive surgical options. Tricuspid regurgitation requiring valve repair is frequent in patients with the need for mechanical circulatory support as it is strongly associated with ischemic and nonischemic cardiomyopathy. We report on HeartWare LVAD implantation and simultaneous tricuspid valve reconstruction through minimally invasive access by partial upper sternotomy to the fifth left intercostal space. Four male patients (mean age 51.72 ± 11.95 years) suffering from chronic heart failure due to dilative (three patients) and ischemic (one patient) cardiomyopathy and also exhibiting concomitant tricuspid valve insufficiency due to annular dilation underwent VAD implantation and tricuspid valve annuloplasty. Extracorporeal circulation was established via the ascending aorta, superior vena cava, and right atrium. In all four cases the LVAD implantation and tricuspid valve repair via partial median sternotomy was successful. During the operative procedure, no conversion to full sternotomy was necessary. One patient needed postoperative re-exploration because of pericardial effusion. No postoperative focal neurologic injury was observed. New generation VADs are advantageous because of the possibility of minimally invasive implantation procedure which can therefore minimize surgical trauma. Concomitant tricuspid valve reconstruction can also be performed simultaneously through partial upper sternotomy. Nevertheless, minimally invasive LVAD implantation is a challenging operative technique. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals

  17. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    PubMed

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of <1. 0m2, and 1.5 mm for a BSA of >1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no

  18. Mid-term function and remodeling potential of tissue engineered tricuspid valve: Histology and biomechanics.

    PubMed

    Ropcke, Diana M; Rasmussen, Jonas; Ilkjær, Christine; Skov, Søren N; Tjørnild, Marcell J; Baandrup, Ulrik T; Christian Danielsen, Carl; Hjortdal, Vibeke E; Nielsen, Sten L

    2018-04-11

    Tricuspid valve reconstruction using a small intestinal submucosal porcine extracellular matrix (ECM) tube graft is hypothesized to be durable for six months and show signs of recellularization and growth potential. The purpose was to histologically and biomechanically test ECM valves before and after six months of implantation in pigs for comparison with native valves. Ten 60 kg pigs were included, which survived tricuspid valve tube graft insertion. Anterior and septal tricuspid leaflets were explanted from all animals surviving more than one month and examined histologically (n = 9). Endothelialization, collagen content, mineralization, neovascularization, burst strength and tensile strength were determined for native valves (n = 5), ECM before implantation (n = 5), and ECM after six months (n = 5). Collagen density was significantly larger in ECM at implantation (baseline) compared to native leaflet tissue (0.3 ± 0.02 mg/mm 3 vs. 0.1 ± 0.03 mg/mm 3 , p < .0001), but collagen density decreased and reached native leaflet collagen content, six months after ECM implantation (native vs. ECM valve at six months: 0.1 ± 0.03 mg/mm 3 vs. 0.2 ± 0.05 mg/mm 3 , p = .8). Histologically, ECM valves showed endothelialization, host cell infiltration and structural collagen organization together with elastin generation after six months, indicating tissue remodeling and -engineering together with gradual development of a close-to-native leaflet structure without foreign body response. ECM tricuspid tube grafts were stronger than native leaflet tissue. Histologically, the acellular ECM tube grafts showed evidence of constructive tissue remodeling with endothelialization and connective tissue organization. These findings support the concept of tissue engineering and recellularization, which are prerequisites for growth. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. De Vega Annuloplasty for Functional Tricupsid Regurgitation: Concept of Tricuspid Valve Orifice Index to Optimize Tricuspid Valve Annular Reduction

    PubMed Central

    Hwang, Ho Young; Chang, Hyoung Woo; Jeong, Dong Seop

    2013-01-01

    We evaluated long-term results of De Vega annuloplasty measured by cylindrical sizers for functional tricuspid regurgitation (FTR) and analyzed the impact of measured annular size on the late recurrence of tricuspid valve regurgitation. Between 2001 and 2011, 177 patients (57.9±10.5 yr) underwent De Vega annuloplasty for FTR. Three cylindrical sizers (actual diameters of 29.5, 31.5, and 33.5 mm) were used to reproducibly reduce the tricuspid annulus. Long-term outcomes were evaluated and risk factor analyses for the recurrence of FTR ≥3+ were performed. Measured annular diameter indexed by patient's body surface area was included in the analyses as a possible risk factor. Operative mortality occurred in 8 patients (4.5%). Ten-year overall and cardiac death-free survivals were 80.5% and 90.8%, respectively. Five and 10-yr freedom rates from recurrent FTR were 96.5% and 93.1%, respectively. Cox proportional hazard model revealed that higher indexed annular size was the only risk factor for the recurrence of FTR (P=0.006). A minimal P value approach demonstrated that indexed annular diameter of 22.5 mm/m2 was a cut-off value predicting the recurrence of FTR. De Vega annuloplasty for FTR results in low rates of recurrent FTR in the long-term. Tricuspid annulus should be reduced appropriately considering patients' body size to prevent recurrent FTR. PMID:24339705

  20. Tricuspid and Mitral Valve Regurgitation with Bi-fascicular Block Following a Horse Kick.

    PubMed

    Kokubun, Tomoki; Oikawa, Masayoshi; Ichijo, Yasuhiro; Matsumoto, Yoshiyuki; Yokokawa, Tetsuro; Nakazato, Kazuhiko; Sato, Yoshiyuki; Takase, Shinya; Shinjo, Hiroharu; Yokoyama, Hitoshi; Suzuki, Hitoshi; Saitoh, Shu-Ichi; Takeishi, Yasuchika

    2018-06-01

    A 40-year-old man was transferred to our hospital following an isolated horse kick injury to the anterior chest wall. The case showed bi-fascicular block, severe tricuspid valve regurgitation due to ruptured chordae tendineae of the anterior leaflet, moderate mitral valve regurgitation due to prolapse of mitral anterior leaflet, and hypokinetic motion of the inferior septal wall. Both tricuspid and mitral insufficiency were completely repaired by a surgical operation. Fortunately, these injuries were not fatal in this case, but the comprehensive assessment of cardiac damage and careful observation are important for managing patients with cardiac injury.

  1. The valve choice in tricuspid valve replacement: 25 years of experience.

    PubMed

    Van Nooten, G J; Caes, F L; François, K J; Taeymans, Y; Primo, G; Wellens, F; Leclerq, J L; Deuvaert, F E

    1995-01-01

    This study reviews 146 consecutive patients who underwent tricuspid valve replacement (TVR) with 69 bioprostheses (porcine and bovine pericardial) and 77 mechanical ball, disc or bileaflet valves between 1967 and 1987. The mean age was 51.4 +/- 12.1 years. Preoperatively, 97% were in New York Heart Association (NYHA) functional class III or more and over 40% had undergone previous cardiac surgery. Hospital mortality was high (16.1%). Incremental risk factors for hospital death were preoperative icterus (P < 0.01), hepatomegaly (P = 0.02), NYHA functional class IV (P = 0.02) and male sex (P = 0.04) (univariate analysis). Ninety-eight percent of the hospital survivors were followed up for a mean of 92 months. Cumulative follow-up added up to 955 patient-years. There were 70 late deaths. The actuarial survival rate was 74% at 60 months and less than 25% at 14 years. Incremental risk factors for late death indicated by univariate analysis were the type of tricuspid prosthesis (Smel-off-Cutter and Kay-Shiley prostheses) (P = 0.04), the type of operative myocardial protection (normothermia and coronary perfusion) (P = 0.05) and preoperative NYHA functional class IV (P = 0.05). We conclude that TVR carries a high operative risk and poor long-term survival, both influenced by preoperative and perioperative variables. Bearing in mind the poor prognosis for TVR, we prefer a large-sized bioprosthesis, in view of its initial good durability and low risk of valve-related events. However, in patients with good life expectancy, a bileaflet mechanical prosthesis may be an acceptable alternative.

  2. Tricuspid valve chordal rupture due to airbag injury and review of pathophysiological mechanisms.

    PubMed

    Thekkudan, Joyce; Luckraz, Heyman; Ng, Alex; Norell, Mike

    2012-09-01

    Blunt trauma to the chest is associated with significant morbidity and mortality. The latter is usually due to an aortic transection, whereas the former is related to myocardial contusion, cardiac valve injury, coronary artery disruption and intracardiac shunts due to the formation of septal defects. The main mechanisms causing these injuries are due to the sudden deceleration force and compression within the chest cavity. Moreover, there is also the sudden increase in intravascular pressure due to a mechanical compression effect and a hormonal adrenergic surge during the event. We report a case of a tricuspid valve injury caused by the deployment of the airbag during a high-speed impact car accident and the subsequent damage to the tricuspid valve chordal mechanism. The patient's management and the pathophysiological mechanisms involved in the injury are reviewed.

  3. [Deformation of the tricuspid annulus by pericardial adhesions: a rare cause of early tricuspid regurgitation after mitral valve replacement].

    PubMed

    Tapia, M; Latrémouille, C; Chabert, J P; Fabiani, J N

    1995-12-01

    The authors report the case of major tricuspid regurgitation occurring early after mitral valve replacement. The mechanism was demonstrated at reoperation: the heart was deformed by a posterior pericardial effusion and cardiodiaphragmatic pericardial adhesions.

  4. [Traumatic tricuspid valve insufficiency with right-to-left shunt: bridging using extracorporeal venovenous membrane oxygenation].

    PubMed

    Weber, S U; Hammerstingl, C; Mellert, F; Baumgarten, G; Putensen, C; Knuefermann, P

    2012-01-01

    The case of a young male motor vehicle driver is reported who suffered multiple trauma in a car accident with pulmonary and cardiac contusions. In the course of severe pneumonia and traumatic tricuspid valve insufficiency a right-to-left shunt with refractory hypoxemia developed across a pre-existing atrial septal defect (ASD). The patient could be successfully treated by the combination of extracorporeal membrane oxygenation for bridging, interventional ASD occlusion and in the long-term by operative reconstruction of the tricuspid valve.

  5. Virtual reality 3D echocardiography in the assessment of tricuspid valve function after surgical closure of ventricular septal defect.

    PubMed

    Bol Raap, Goris; Koning, Anton H J; Scohy, Thierry V; ten Harkel, A Derk-Jan; Meijboom, Folkert J; Kappetein, A Pieter; van der Spek, Peter J; Bogers, Ad J J C

    2007-02-16

    This study was done to investigate the potential additional role of virtual reality, using three-dimensional (3D) echocardiographic holograms, in the postoperative assessment of tricuspid valve function after surgical closure of ventricular septal defect (VSD). 12 data sets from intraoperative epicardial echocardiographic studies in 5 operations (patient age at operation 3 weeks to 4 years and bodyweight at operation 3.8 to 17.2 kg) after surgical closure of VSD were included in the study. The data sets were analysed as two-dimensional (2D) images on the screen of the ultrasound system as well as holograms in an I-space virtual reality (VR) system. The 2D images were assessed for tricuspid valve function. In the I-Space, a 6 degrees-of-freedom controller was used to create the necessary projectory positions and cutting planes in the hologram. The holograms were used for additional assessment of tricuspid valve leaflet mobility. All data sets could be used for 2D as well as holographic analysis. In all data sets the area of interest could be identified. The 2D analysis showed no tricuspid valve stenosis or regurgitation. Leaflet mobility was considered normal. In the virtual reality of the I-Space, all data sets allowed to assess the tricuspid leaflet level in a single holographic representation. In 3 holograms the septal leaflet showed restricted mobility that was not appreciated in the 2D echocardiogram. In 4 data sets the posterior leaflet and the tricuspid papillary apparatus were not completely included. This report shows that dynamic holographic imaging of intraoperative postoperative echocardiographic data regarding tricuspid valve function after VSD closure is feasible. Holographic analysis allows for additional tricuspid valve leaflet mobility analysis. The large size of the probe, in relation to small size of the patient, may preclude a complete data set. At the moment the requirement of an I-Space VR system limits the applicability in virtual reality 3D

  6. Aberrant tendinous chords with tethering of the tricuspid leaflets: a congenital anomaly causing severe tricuspid regurgitation.

    PubMed

    Kobza, R; Kurz, D J; Oechslin, E N; Prêtre, R; Zuber, M; Vogt, P; Jenni, R

    2004-03-01

    To define the entity of tricuspid regurgitation caused by tethering of the tricuspid valve leaflets by aberrant tendinous chords. Retrospective study. Tertiary care centre (university teaching hospital). 10 patients with unexplained severe tricuspid regurgitation. The last 13 500 echocardiographic studies from our facility were reviewed to identify patients with severe unexplained tricuspid regurgitation. Tethering was defined by the presence of aberrant tendinous chords to the tricuspid valve leaflets limiting the mobility of the tricuspid leaflet and resulting in incomplete coaptation and apical displacement of the regurgitant jet origin. Aberrant tendinous chords were defined as those inserting at the clear zone of the tricuspid leaflet and not originating from the papillary muscle. Patients fulfilling the diagnostic criteria for Ebstein's anomaly were excluded. 10 patients with aberrant tendinous chords tethering one or more tricuspid valve leaflets were identified. There were short non-aberrant tendinous chords in seven patients, five of whom also had right ventricular or tricuspid annulus dilatation. Tethering of the tricuspid valve leaflets by aberrant tendinous chords can be the sole mechanism of congenital tricuspid regurgitation. It is often associated with short non-aberrant tendinous chords, which may develop secondary to right ventricular or tricuspid annulus dilatation. Awareness of tethering as a cause of tricuspid regurgitation may be important in planning reconstructive surgery.

  7. Tricuspid valve excision using off-pump inflow occlusion technique: role of intra-operative trans-esophageal echocardiography.

    PubMed

    Gadhinglajkar, Shrinivas; Sreedhar, Rupa; Karunakaran, Jayakumar; Misra, Manoranjan; Somasundaram, Ganesh; Mathew, Thomas

    2010-01-01

    A pacing system infection may lead to infective endocarditis and systemic sepsis. Tricuspid valve surgery may be required if the valve is severely damaged in the process of endocarditis. Although, cardiopulmonary bypass is the safe choice for performing right-heart procedures, it may carry risk of inducing systemic inflammatory response and multi-organ dysfunction. Some studies have advocated TV surgery without institution of CPB. We report tricuspid valve excision using the off-pump inflow occlusion technique in a 68-year-old man. We also describe role of intra-operative TEE as a monitoring tool at different stages of the surgical procedure.

  8. Restoration of Tricuspid Valve Mechanism at the Level of Displaced Septal and Posterior Leaflets in Ebstein's Anomaly.

    PubMed

    Im, Yu-Mi; Park, Chun Soo; Park, Jeong-Jun; Yun, Tae-Jin

    2016-03-01

    Surgical techniques currently used for the repair of Ebstein's anomaly comprise reconstruction of the tricuspid valve mechanism at the level of the true annulus with or without plication of the atrialized right ventricle. However, performing this procedure for patients with a dysmorphic anterior leaflet (i.e., insufficient leaflet tissue and decreased mobility due to tethering) may necessitate technical modifications. A retrospective review was performed of 31 patients (seven males and 24 females, median age at operation 31 years) with Ebstein's anomaly, who underwent tricuspid valve repair between March 2002 and December 2014. The original Hetzer technique (annulus to annulus approximation) was employed for six patients with a well-formed anterior leaflet. In 25 patients, the tricuspid valve mechanism was restored at the displaced septal leaflet by approximating the anterior leaflet attachment in the true annulus to the displaced septal leaflet attachment in the mid-septum. A bidirectional superior cavopulmonary anastomosis was added in 27 of 31 (87%) patients. No early or late death occurred during the median follow-up of 66 months (1-138 months). Immediate postoperative tricuspid regurgitation was trivial to mild in 22 patients, and the median preoperative, immediate postoperative, and last follow-up tricuspid regurgitation jet areas in 21 adult patients were 23.3 cm2, 10.4 cm2, and 7.0 cm2, respectively. Two patients underwent reoperation at 81 and 119 months postoperatively. Five-year freedom from severe tricuspid regurgitation or reoperation was 93.2%. Restoration of the tricuspid valve mechanism at the level of displaced septal leaflet leads to excellent long-term outcomes. The addition of the bidirectional superior cavopulmonary anastomosis has contributed to the success of this technique. © 2016 Wiley Periodicals, Inc.

  9. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    PubMed

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  10. Does concomitant tricuspid annuloplasty increase perioperative mortality and morbidity when correcting left-sided valve disease?

    PubMed

    Zhu, Tie-Yuan; Wang, Jian-Gang; Meng, Xu

    2015-01-01

    A best evidence topic in adult valvular surgery was written according to a structured protocol. The question addressed was 'Does concomitant tricuspid annuloplasty increase the perioperative mortality and morbidity when correcting left-sided valve disease?' A total of 561 papers were found using the reported search, of which 12 presented the best evidence to answer the clinical question. The authors, country, journal, date of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Among these 12 papers, there were nine retrospective studies, two cohort studies and one randomized controlled trial (RCT). Overall, additional tricuspid valve (TV) repair takes more time during operations, particularly with a ring annuloplasty method. The mean aortic cross-clamping times were 57-83 min without associated tricuspid repair and 62-100 min with, and cardiopulmonary bypass times without and with repair were 82-124 and 90-174 min, respectively. A study of 624 patients who had undergone isolated mitral valve (MV) surgery and MV surgery plus TV repair showed more female and atrial fibrillation patients in the tricuspid valve plasty (TVP) group, but no increase in the 30-day mortality was found. One RCT, presenting similar patient baseline characteristics, also found no difference in the hospital mortality rates between the TVP group and the non-TVP group. Another 10 studies also demonstrated no statistically significant differences in perioperative mortality. In a cohort study of 311 patients undergoing MV repair with or without tricuspid annuloplasty, postoperative complications, such as bleeding, stroke, pacemaker, haemofiltration and myocardial infarction, all showed no statistically significant differences in the two groups. One study retrospectively analysed a large number of patients undergoing either isolated left-sided valve surgery or a concomitant TV repair, and there were no statistically significant differences

  11. Transcatheter pledget-assisted suture tricuspid annuloplasty (PASTA) to create a double-orifice valve.

    PubMed

    Khan, Jaffar M; Rogers, Toby; Schenke, William H; Greenbaum, Adam B; Babaliaros, Vasilis C; Paone, Gaetano; Ramasawmy, Rajiv; Chen, Marcus Y; Herzka, Daniel A; Lederman, Robert J

    2018-02-06

    Pledget-assisted suture tricuspid valve annuloplasty (PASTA) is a novel technique using marketed equipment to deliver percutaneous trans-annular sutures to create a double-orifice tricuspid valve. Tricuspid regurgitation is a malignant disease with high surgical mortality and no commercially available transcatheter solution in the US. Two iterations of PASTA were tested using trans-apical or trans-jugular access in swine. Catheters directed paired coronary guidewires to septal and lateral targets on the tricuspid annulus under fluoroscopic and echocardiographic guidance. Guidewires were electrified to traverse the annular targets and exchanged for pledgeted sutures. The sutures were drawn together and knotted, apposing septal and lateral targets, creating a double orifice tricuspid valve. Twenty-two pigs underwent PASTA. Annular and chamber dimensions were reduced (annular area, 10.1 ± 0.8 cm 2 to 3.8 ± 1.5 cm 2 (naïve) and 13.1 ± 1.5 cm 2 to 6.2 ± 1.0 cm 2 (diseased); septal-lateral diameter, 3.9 ± 0.3 mm to 1.4 ± 0.6 mm (naïve) and 4.4 ± 0.4 mm to 1.7 ± 1.0 mm (diseased); and right ventricular end-diastolic volume, 94 ± 13 ml to 85 ± 14 ml (naïve) and 157 ± 25 ml to 143 ± 20 ml (diseased)). MRI derived tricuspid regurgitation fraction fell from 32 ± 12% to 4 ± 5%. Results were sustained at 30 days. Pledget pull-through force was five-fold higher (40.6 ± 11.7N vs 8.0 ± 2.6N, P < .01) using this strategy compared to single puncture techniques used to anchor current investigational devices. Serious complications were related to apical access. PASTA reduces annular dimensions and tricuspid regurgitation in pigs. It may be cautiously applied to selected patients with severe tricuspid regurgitation and no options. This is the first transcatheter procedure, to our knowledge, to deliver standard pledgeted sutures to repair cardiac pathology. Published 2018. This article is a U

  12. Aberrant tendinous chords with tethering of the tricuspid leaflets: a congenital anomaly causing severe tricuspid regurgitation

    PubMed Central

    Kobza, R; Kurz, D J; Oechslin, E N; Prêtre, R; Zuber, M; Vogt, P; Jenni, R

    2004-01-01

    Objective: To define the entity of tricuspid regurgitation caused by tethering of the tricuspid valve leaflets by aberrant tendinous chords. Design: Retrospective study. Setting: Tertiary care centre (university teaching hospital). Patients: 10 patients with unexplained severe tricuspid regurgitation. Methods: The last 13 500 echocardiographic studies from our facility were reviewed to identify patients with severe unexplained tricuspid regurgitation. Tethering was defined by the presence of aberrant tendinous chords to the tricuspid valve leaflets limiting the mobility of the tricuspid leaflet and resulting in incomplete coaptation and apical displacement of the regurgitant jet origin. Aberrant tendinous chords were defined as those inserting at the clear zone of the tricuspid leaflet and not originating from the papillary muscle. Patients fulfilling the diagnostic criteria for Ebstein’s anomaly were excluded. Results: 10 patients with aberrant tendinous chords tethering one or more tricuspid valve leaflets were identified. There were short non-aberrant tendinous chords in seven patients, five of whom also had right ventricular or tricuspid annulus dilatation. Conclusions: Tethering of the tricuspid valve leaflets by aberrant tendinous chords can be the sole mechanism of congenital tricuspid regurgitation. It is often associated with short non-aberrant tendinous chords, which may develop secondary to right ventricular or tricuspid annulus dilatation. Awareness of tethering as a cause of tricuspid regurgitation may be important in planning reconstructive surgery. PMID:14966058

  13. Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: role of real time three-dimensional echocardiography.

    PubMed

    Nucifora, Gaetano; Badano, Luigi P; Allocca, Giuseppe; Gianfagna, Pasquale; Proclemer, Alessandro; Cinello, Margherita; Fioretti, Paolo M

    2007-07-01

    Pacemaker leads may impair tricuspid valve coaptation and they are a well-known cause of mild tricuspid regurgitation. Occasionally, right ventricular leads worsen tricuspid regurgitation over time and patients develop late-onset symptoms of right-sided heart failure. The exact mechanism of this clinical entity is rarely identifiable by 2D-echocardiography only. This case report details a patient with severe tricuspid regurgitation secondary to immobilization of the anterior leaflet of the tricuspid valve by a permanent ventricular pacing lead. The mechanism of regurgitation was clarified by real time three-dimensional echocardiography that showed the location of the ventricular lead and its interference with the tricuspid valve.

  14. "Guidelines Recommendations on the Treatment of Tricuspid Regurgitation. Where Are We and Where Do We Go With Transcatheter Valve Intervention".

    PubMed

    Vahanian, Alec; Brochet, Eric; Juliard, Jean-Michel

    2018-01-01

    Tricuspid regurgitation (TR) is an important clinical problem because it is frequent and carries a poor prognosis when it is left uncorrected. However, there is still a lack of awareness of tricuspid disease in the medical community. The indications for evaluation and surgical interventions in patients with TR were recently updated in the ESC/EACTS guidelines. Transcatheter tricuspid valve intervention (TTVI), almost exclusively valve repair, is at an early stage of development as only a few hundreds of patients have been treated. The first-in-man valve implantation was very recently performed. The recent ESC/EACTS Guidelines state that "The potential role of transcatheter tricuspid valve treatment in high-risk patients needs to be determined". We shall review here which lessons of interest for TTVI can be learned from the Guidelines as regards evaluation and indications for surgery and try to imagine what could be the place of TTVI in the Guidelines in the future.

  15. Transcatheter aortic valve replacement in patients with severe mitral or tricuspid regurgitation at extreme risk for surgery.

    PubMed

    Little, Stephen H; Popma, Jeffrey J; Kleiman, Neal S; Deeb, G Michael; Gleason, Thomas G; Yakubov, Steven J; Checuti, Stan; O'Hair, Daniel; Bajwa, Tanvir; Mumtaz, Mubashir; Maini, Brijeshwar; Hartman, Alan; Katz, Stanley; Robinson, Newell; Petrossian, George; Heiser, John; Merhi, William; Moore, B Jane; Li, Shuzhen; Adams, David H; Reardon, Michael J

    2018-05-01

    Patients with symptomatic severe aortic stenosis and severe mitral regurgitation or severe tricuspid regurgitation were excluded from the major transcatheter aortic valve replacement trials. We studied these 2 subgroups in patients at extreme risk for surgery in the prospective, nonrandomized, single-arm CoreValve US Expanded Use Study. The primary end point was all-cause mortality or major stroke at 1 year. A favorable medical benefit was defined as a Kansas City Cardiomyopathy Questionnaire overall summary score greater than 45 at 6 months and greater than 60 at 1 year and with a less than 10-point decrease from baseline. There were 53 patients in each group. Baseline characteristics for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were age 84.2 ± 6.4 years and 84.9 ± 6.5 years; male, 29 (54.7%) and 22 (41.5%), and mean Society of Thoracic Surgeons score 9.9% ± 5.0% and 9.2% ± 4.0%, respectively. Improvement in valve regurgitation from baseline to 1 year occurred in 72.7% of the patients with severe mitral regurgitation and in 61.8% of patients with severe tricuspid regurgitation. A favorable medical benefit occurred in 31 of 47 patients (66.0%) with severe mitral regurgitation and 33 of 47 patients (70.2%) with severe tricuspid regurgitation at 6 months, and in 25 of 44 patients (56.8%) with severe mitral regurgitation and 24 of 45 patients (53.3%) with severe tricuspid regurgitation at 1 year. All-cause mortality or major stroke for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were 11.3% and 3.8% at 30 days and 21.0% and 19.2% at 1 year, respectively. There were no major strokes in either group at 1 year. Transcatheter aortic valve replacement in patients with severe mitral regurgitation or severe tricuspid regurgitation is reasonable and safe and leads to improvement in atrioventricular valve regurgitation. Copyright © 2018 The American Association for Thoracic Surgery

  16. Tricuspid Regurgitation Associated With Ischemic Mitral Regurgitation: Characterization, Evolution After Mitral Surgery, and Value of Tricuspid Repair.

    PubMed

    Navia, José L; Elgharably, Haytham; Javadikasgari, Hoda; Ibrahim, Ahmed; Koprivanac, Marijan; Lowry, Ashley M; Blackstone, Eugene H; Klein, Allan L; Gillinov, A Marc; Roselli, Eric E; Svensson, Lars G

    2017-08-01

    Tricuspid regurgitation (TR) often accompanies ischemic mitral regurgitation and is generally assumed to be a secondary consequence of altered hemodynamics of the left-sided regurgitation. We hypothesized that it may also be a direct consequence of right-sided ischemic disease. Therefore, our objectives were to (1) characterize the nature of this TR and (2) describe its time course after mitral valve surgery for ischemic mitral regurgitation, with or without concomitant tricuspid valve repair. From 2001 to 2011, 568 patients with ischemic mitral regurgitation underwent mitral valve surgery. They had varying degrees of TR and altered right-side heart morphology and function; 131 had concomitant tricuspid valve repair. Postoperatively, 1,395 echocardiograms were available to assess residual and recurrent TR. Greater severity of preoperative TR was accompanied by larger tricuspid valve diameter, greater leaflet tethering, worse right ventricular function, and higher right ventricular pressure (all p [trend] ≤ 0.002). Without tricuspid valve repair, 31% of patients with no preoperative TR had moderate or greater TR by 5 years, as did 62% with moderate TR. With tricuspid valve repair, 25% with moderate preoperative TR remained in that grade at 5 years, but 11% had severe TR. Tricuspid regurgitation accompanying ischemic mitral regurgitation is associated with right-side heart remodeling and dysfunction often mirroring that occurring in the left side of the heart-ischemic TR. Tricuspid valve repair is effective initially, but as with mitral valve repair, TR progressively returns. Therefore, when the severity of TR and right-sided remodeling reaches the point of irreversibility, it may be an indication to eliminate the TR by replacing the tricuspid valve. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Management of tricuspid regurgitation

    PubMed Central

    Taramasso, Maurizio; Lapenna, Elisabetta; Alfieri, Ottavio

    2014-01-01

    Secondary tricuspid regurgitation is the most frequent type of tricuspid insufficiency in western countries. Its surgical treatment is still an object of debate both in terms of timing and surgical techniques. Until recently, the avoidance of surgery for tricuspid repair was commonly accepted in patients with less than severe secondary tricuspid regurgitation undergoing left-sided valve surgery. More recently, compelling evidence in favour of a more aggressive surgical approach in this setting has emerged. The surgical technique should be tailored to the stage of disease. Ring annuloplasty is more durable than suture annuloplasty and represents the method of choice in the presence of isolated annular dilatation. In patients in whom the dilatation of the tricuspid annulus is combined with significant leaflet tethering, annuloplasty alone is unlikely to be durable and additional procedures have been proposed in order to achieve a more durable repair. In this review, pathophysiology, surgical indications, techniques of repair and outcomes of secondary tricuspid regurgitation will be discussed. We will also focus on the challenging issue of significant tricuspid regurgitation occurring late after left-sided valve surgery. Finally, the current and future role of percutaneous tricuspid valve technologies will be briefly described. PMID:25184048

  18. Progression of Tricuspid Regurgitation after Mitral Valve Replacement for Rheumatic Heart Disease.

    PubMed

    Q Tri, Ho H; Vinh, Pham N

    2017-05-01

    Progression of tricuspid regurgitation (TR) may occur after mitral valve replacement (MVR). The study aim was to define the independent predictors for new severe TR after MVR to treat rheumatic heart disease. A total of 413 patients (177 men, 236 women; mean age 40.9 ± 9.2 years) with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair at the authors' institute between 1995 and 2005, who did not have preoperative severe TR, were followed for at least one year postoperatively. Survival without severe TR was estimated using the Kaplan-Meier method. Independent predictors for new severe TR were identified using multiple Cox regression analysis. During a median follow up of 13 years there were two late deaths, and 46 patients (11.1%) had new severe TR. Survival without severe TR was 88.0 ± 1.7% at 10 years. Independent predictors for new severe TR were preoperative moderate TR (HR 2.401; p = 0.008) and atrial fibrillation (AF) (HR 2.119; p = 0.018). At the most recent follow up, furosemide was used in 23.9% patients with and 7.3% patients without new severe TR (p = 0.001). Patients with new severe TR had larger right ventricles and higher pulmonary artery pressures on echocardiography. Among patients with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair, independent predictors for new severe TR were preoperative moderate TR and AF. New severe TR was associated with increased furosemide use.

  19. Long-term echocardiographic follow-up of untreated 2+ functional tricuspid regurgitation in patients undergoing mitral valve surgery†

    PubMed Central

    Kusajima, Kunio; Fujita, Tomoyuki; Hata, Hiroki; Shimahara, Yusuke; Miura, Sayaka; Kobayashi, Junjiro

    2016-01-01

    OBJECTIVES Concomitant tricuspid valve surgery with mitral valve surgery is recommended for patients with severe functional tricuspid regurgitation (TR). However, the treatment for 2+ TR (mild TR) remains controversial. Here, we evaluated the long-term results of untreated 2+ TR in patients undergoing mitral valve surgery. METHODS We retrospectively reviewed the records of 96 patients with untreated 2+ TR among 885 patients who underwent mitral valve surgery from 2003 to 2010. Exclusion criteria were tricuspid valve surgery (TVS), emergency surgery, primary TR and pacemaker lead through the tricuspid valve. We assessed survival and freedom from heart failure. The freedom from 3+ (moderate) or 4+ (severe) TR was investigated by echocardiographic data at pre- and postoperative week 1, then at 1, 3, 5, 7 and 10 postoperative years, which were compared with those in patients who had 2+ TR preoperatively and underwent concomitant TVS in the same period (n = 47). RESULTS The mean follow-up was 7.1 ± 2.7 years. There was no 30-day mortality. The survival rate was 97.5% at 5 years and 87.5% at 10 years. The independent risk factors for mortality were age (OR 1.2, P = 0.03) and left ventricular ejection fraction (OR 0.9, P = 0.03). Untreated 2+ TR improved transiently within the first postoperative year (P < 0.001), but progressed again in the mid- to long term. Freedom from ≥3+ TR was 64.2% at 5 years and 46.7% at 10 years, which was significantly lower than that from ≥3+ TR in patients who underwent concomitant TVS (P = 0.006). The independent risk factors for TR progression (≥3 + TR) were age (OR 1.1, P = 0.005), atrial fibrillation (OR 2.2, P = 0.04) and tricuspid annular diameter (TAD) index (mm/m2; OR 1.1, P = 0.02). Receiver operating characteristic curves showed that the optimal TAD index cut-off value was 21.0 for long-term survival [area under the curve (AUC) = 0.72] and 21.2 for TR progression (AUC = 0.64). CONCLUSIONS Although untreated, 2+ TR

  20. Long-term echocardiographic follow-up of untreated 2+ functional tricuspid regurgitation in patients undergoing mitral valve surgery.

    PubMed

    Kusajima, Kunio; Fujita, Tomoyuki; Hata, Hiroki; Shimahara, Yusuke; Miura, Sayaka; Kobayashi, Junjiro

    2016-07-01

    Concomitant tricuspid valve surgery with mitral valve surgery is recommended for patients with severe functional tricuspid regurgitation (TR). However, the treatment for 2+ TR (mild TR) remains controversial. Here, we evaluated the long-term results of untreated 2+ TR in patients undergoing mitral valve surgery. We retrospectively reviewed the records of 96 patients with untreated 2+ TR among 885 patients who underwent mitral valve surgery from 2003 to 2010. Exclusion criteria were tricuspid valve surgery (TVS), emergency surgery, primary TR and pacemaker lead through the tricuspid valve. We assessed survival and freedom from heart failure. The freedom from 3+ (moderate) or 4+ (severe) TR was investigated by echocardiographic data at pre- and postoperative week 1, then at 1, 3, 5, 7 and 10 postoperative years, which were compared with those in patients who had 2+ TR preoperatively and underwent concomitant TVS in the same period (n = 47). The mean follow-up was 7.1 ± 2.7 years. There was no 30-day mortality. The survival rate was 97.5% at 5 years and 87.5% at 10 years. The independent risk factors for mortality were age (OR 1.2, P = 0.03) and left ventricular ejection fraction (OR 0.9, P = 0.03). Untreated 2+ TR improved transiently within the first postoperative year (P < 0.001), but progressed again in the mid- to long term. Freedom from ≥3+ TR was 64.2% at 5 years and 46.7% at 10 years, which was significantly lower than that from ≥3+ TR in patients who underwent concomitant TVS (P = 0.006). The independent risk factors for TR progression (≥3 + TR) were age (OR 1.1, P = 0.005), atrial fibrillation (OR 2.2, P = 0.04) and tricuspid annular diameter (TAD) index (mm/m(2); OR 1.1, P = 0.02). Receiver operating characteristic curves showed that the optimal TAD index cut-off value was 21.0 for long-term survival [area under the curve (AUC) = 0.72] and 21.2 for TR progression (AUC = 0.64). Although untreated, 2+ TR significantly improved after mitral valve

  1. Tricuspid annuloplasty versus a conservative approach in patients with functional tricuspid regurgitation undergoing left-sided heart valve surgery: A study-level meta-analysis.

    PubMed

    Pagnesi, Matteo; Montalto, Claudio; Mangieri, Antonio; Agricola, Eustachio; Puri, Rishi; Chiarito, Mauro; Ancona, Marco B; Regazzoli, Damiano; Testa, Luca; De Bonis, Michele; Moat, Neil E; Rodés-Cabau, Josep; Colombo, Antonio; Latib, Azeem

    2017-08-01

    Tricuspid valve (TV) repair at the time of left-sided valve surgery is indicated in patients with either severe functional tricuspid regurgitation (TR) or mild-to-moderate TR with coexistent tricuspid annular dilation or right heart failure. We assessed the benefits of a concomitant TV repair strategy during left-sided surgical valve interventions, focusing on mortality and echocardiographic TR-related outcomes. A meta-analysis was performed of studies reporting outcomes of patients who underwent left-sided (mitral and/or aortic) valve surgery with or without concomitant TV repair. Primary endpoints were all-cause and cardiac-related mortality; secondary endpoints were the presence of more-than-moderate TR, TR progression, and TR severity grade. All endpoints were evaluated at the longest available follow-up. Fifteen studies were included for a total of 2840 patients. TV repair at the time of left-sided valve surgery was associated with a significantly lower risk of cardiac-related mortality (odds ratio [OR] 0.38; 95% confidence interval [CI]: 0.25-0.58; p<0.001), with a trend towards a lower risk of all-cause mortality (OR 0.57; 95% CI: 0.32-1.05; p=0.07) at a mean weighted follow-up of 6years. The presence of more-than-moderate TR (OR 0.19; 95% CI: 0.12-0.30; p<0.001), TR progression (OR 0.03; 95% CI: 0.01-0.05; p<0.001), and TR grade (standardized mean difference -1.11; 95% CI: -1.57 to -0.65; p<0.001) were significantly lower in the TV repair group at a mean weighted follow-up of 4.7years. A concomitant TV repair strategy during left-sided valve surgery is associated with a reduction in cardiac-related mortality and improved echocardiographic TR outcomes at follow-up. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. Prosthetic valve implantation with preservation of the entire valvular and subvalvular apparatus of the tricuspid valve in congenitally corrected transposition of the great arteries.

    PubMed

    Ergenoglu, Mehmet U; Yerebakan, Halit; Ozveren, Olcay; Koner, Ozge; Kalangos, Afksendiyos; Demirsoy, Ergun

    2011-10-01

    Congenitally corrected transposition of the great arteries, which is characterized by atrioventricular and ventriculoarterial discordance, is a rare congenital heart disease. Most of the cases are diagnosed in childhood, owing to associated cardiac anomalies, such as ventricular septal defect, pulmonary stenosis or pulmonary atresia, and Ebstein-like malformation of the tricuspid valve. We present a patient with congenitally corrected transposition of the great arteries who underwent surgical replacement of the tricuspid valve with a bioprosthesis and reconstruction of the left ventricular outflow tract with bovine conduit.

  3. Twin Valve Caval Stent for Functional Replacement of Incompetent Tricuspid Valve: A Feasibility Animal Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu

    Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less

  4. Right Atrial Dysfunction in the Fetus with Severely Regurgitant Tricuspid Valve Disease: A Potential Source of Cardiovascular Compromise.

    PubMed

    Howley, Lisa W; Khoo, Nee Scze; Moon-Grady, Anita J; Patel, Sonali S; Alrais, Fayeza; Tworetzky, Wayne; Colen, Timothy; Brooks, Paul; Trines, Jean; Ojala, Tiina; Hornberger, Lisa K

    2017-06-01

    In severe right heart obstruction (RHO), redistribution of cardiac output to the left ventricle (LV) is well tolerated by the fetal circulation. Although the same should be true of severely regurgitant tricuspid valve disease (rTVD) with reduced or no output from the right ventricle, affected fetuses more frequently develop hydrops or suffer intrauterine demise. We hypothesized that right atrium (RA) function is altered in rTVD but not in RHO, which could contribute to differences in outcomes. Multi-institutional retrospective review of fetal echocardiograms performed over a 10-year period on fetuses with rTVD (Ebstein's anomaly, tricuspid valve dysplasia) or RHO (pulmonary atresia/intact ventricular septum, tricuspid atresia) and a healthy fetal control group. Offline velocity vector imaging and Doppler measurements of RA size and function and LV function were made. Thirty-four fetuses with rTVD, 40 with RHO, and 79 controls were compared. The rTVD fetuses had the largest RA size and lowest RA expansion index, fractional area of change, and RA indexed filling and emptying rates compared with fetuses with RHO and controls. The rTVD fetuses had the shortest LV ejection time and increased Tei index with a normal LV ejection fraction. RA dilation (odds ratio, 1.27; 95% CI, 1.05-1.54) and reduced indexed emptying rate (odds ratio, 2.49; 95% CI, 1.07-5.81) were associated with fetal or neonatal demise. Fetal rTVD is characterized by more severe RA dilation and dysfunction compared with fetal RHO and control groups. RA dysfunction may be an important contributor to reduced ventricular filling and output, potentially playing a critical role in the worsened outcomes observed in fetal rTVD. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  5. Tricuspid Valve Repair for the Poor Right Ventricle: Tricuspid Valve Repair in Patients with Mild-to-Moderate Tricuspid Regurgitation Undergoing Mitral Valve Repair Improves In-Hospital Outcome.

    PubMed

    Zientara, Alicja; Genoni, Michele; Graves, Kirk; Odavic, Dragan; Löblein, Helen; Häussler, Achim; Dzemali, Omer

    2017-12-01

    Background  Tricuspid regurgitation (TR) in patients undergoing surgery for mitral valve (MV) increases morbidity and mortality, especially in case of a poor right ventricle. Does repair of mild-to-moderate insufficiency of the tricuspid valve (TV) in patients undergoing MV surgery lead to a benefit in early postoperative outcome? Methods  A total of 22 patients with mild-to-moderate TR underwent MV repair and concomitant TV repair with Tri-Ad (Medtronic ATS Medical Inc., Minneapolis, Minnesota, United States) and Edwards Cosgrove (Edwards Lifesciences Irvine, California, United States) rings. The severity of TR was assessed echocardiographically by using color-Doppler flow images. The tricuspid annular plane systolic excursion (TAPSE) was under 1.7 cm. Additional procedures included coronary artery bypass ( n  = 9) and maze procedure ( n  = 15). The following parameters were compared: postoperative and peak dose of noradrenaline (NA), pre/postoperative systolic pulmonary pressure (sPAP), extubation time, operation time, cross-clamp time, cardiopulmonary bypass (CPB) time, pre/postoperative ejection fraction (EF), intensive care unit (ICU)-stay, hospital stay, cell saver blood transfusion, intra/postoperative blood transfusion, and postoperative TR. Results  The mean age was 67 ± 14.8 years, 45% were male. Mean EF was 47 ± 16.2%, postoperative 52 ± 12.4%. sPAP was 46 ± 20.1 mm Hg preoperatively, sPAP was 40.6 ± 9.4 mm Hg postoperatively, NA postoperatively was 12 ± 10 μg/min, NA peak was 18 ± 11 μg/min, operation time was 275 ± 92 minutes, CPB was 145 ± 49 minutes, ICU stay was 2.4 ± 2.4 days, hospital stay was 10.8 ± 3.5 days, cell saver blood transfusion was 736 ± 346 mL, intraoperative transfusions were 2.5 ± 1.6. Two patients needed postoperative transfusions. A total of 19 patients were extubated at the 1st postoperative day, 2 patients at the 2nd day, and 1 at the 4th

  6. Percutaneous tricuspid valvotomy for pacemaker lead-induced tricuspid stenosis

    PubMed Central

    Patil, Devendra V.; Nabar, Ashish A.; Sabnis, Girish R.; Phadke, Milind S.; Lanjewar, Charan P.; Kerkar, Prafulla G.

    2015-01-01

    Permanent pacemaker lead-induced tricuspid regurgitation is extremely uncommon. We report a patient with severe tricuspid stenosis detected 10 years after permanent single chamber pacemaker implantation in surgically corrected congenital heart disease. The loop at the level of the tricuspid valve may have caused endothelial injury and eventually led to stenosis. Percutaneous balloon valvotomy for such stenosis has not been reported from India. PMID:26995417

  7. Comparison of outcomes of tricuspid annuloplasty with 3D-rigid versus flexible prosthetic ring for functional tricuspid regurgitation secondary to rheumatic mitral valve disease.

    PubMed

    Wang, Haiping; Liu, Xiancheng; Wang, Xin; Lv, Zhenqian; Liu, Xiaojun; Xu, Ping

    2016-11-01

    Annuloplasty bands and rings are widely used for repairing functional tricuspid regurgitation (FTR). However, the question regarding which is the ideal annuloplasty device remains unclear. The aim of this study was to compare the efficacy and mid-term durability of tricuspid ring annuloplasty for FTR secondary to rheumatic mitral valve disease using flexible Cosgrove-Edwards band and the rigid Edwards MC3 ring (Edwards Lifesciences, LLC, Irvine, CA, USA). We retrospectively collected the clinical data of those who underwent mitral valve replacement (MVR) in concomitant with tricuspid ring annuloplasty from 2009 to 2013. The flexible band was used in 46 patients (flexible group), and the 3D rigid ring was used in 60 patients (rigid group). Echocardiographic evaluation of tricuspid function was performed preoperatively and postoperatively. The grade of TR was significantly improved compared to preoperative values in two groups. There was no significant difference regarding postoperative TR grade between the two groups at 1 week and 2-3 months but there was statistical significant difference at postoperative 6-12 months, and 2-3 years. During the follow up period, 25 of 46 patients (54.3%) in flexible group and 22 of 60 patients (30.3%) in rigid group developed recurrent TR. Freedom from recurrent TR in flexible group is significant lower than rigid group in each postoperative follow up period. These findings suggest that 3D rigid ring annuloplasty might be more effective for tricuspid ring annuloplasty in FTR in mid-term postoperative periods when compared to flexible band.

  8. Comparison of outcomes of tricuspid annuloplasty with 3D-rigid versus flexible prosthetic ring for functional tricuspid regurgitation secondary to rheumatic mitral valve disease

    PubMed Central

    Wang, Haiping; Wang, Xin; Lv, Zhenqian; Liu, Xiaojun

    2016-01-01

    Background Annuloplasty bands and rings are widely used for repairing functional tricuspid regurgitation (FTR). However, the question regarding which is the ideal annuloplasty device remains unclear. The aim of this study was to compare the efficacy and mid-term durability of tricuspid ring annuloplasty for FTR secondary to rheumatic mitral valve disease using flexible Cosgrove-Edwards band and the rigid Edwards MC3 ring (Edwards Lifesciences, LLC, Irvine, CA, USA). Methods We retrospectively collected the clinical data of those who underwent mitral valve replacement (MVR) in concomitant with tricuspid ring annuloplasty from 2009 to 2013. The flexible band was used in 46 patients (flexible group), and the 3D rigid ring was used in 60 patients (rigid group). Echocardiographic evaluation of tricuspid function was performed preoperatively and postoperatively. Results The grade of TR was significantly improved compared to preoperative values in two groups. There was no significant difference regarding postoperative TR grade between the two groups at 1 week and 2–3 months but there was statistical significant difference at postoperative 6–12 months, and 2–3 years. During the follow up period, 25 of 46 patients (54.3%) in flexible group and 22 of 60 patients (30.3%) in rigid group developed recurrent TR. Freedom from recurrent TR in flexible group is significant lower than rigid group in each postoperative follow up period. Conclusions These findings suggest that 3D rigid ring annuloplasty might be more effective for tricuspid ring annuloplasty in FTR in mid-term postoperative periods when compared to flexible band. PMID:28066587

  9. Should Moderate-to-Severe Tricuspid Regurgitation be Repaired During Reoperative Left-Sided Valve Procedures?

    PubMed

    Gosev, Igor; Yammine, Maroun; McGurk, Siobhan; Ejiofor, Julius I; Norman, Anthony; Ivkovic, Vladimir; Cohn, Lawrence H

    The risks vs benefits of tricuspid valve (TV) surgery in reoperative patients requiring left-sided valve surgery and moderate-to-severe tricuspid regurgitation is unclear. We compared patients with and without concomitant TV surgery. A total of 200 patients with moderate-to-severe TV regurgitation had reoperative left-sided valve procedures from January 2002 to April 2014; 75 with TV intervention (TVI) and 125 with no tricuspid intervention (TVN). Propensity-matched cohorts of 60 TVI and 60 TVN patients were compared. Outcomes included New York Heart Association class, TV regurgitation and survival. TVI patients were younger (66 ± 15 vs 72 ± 13 years, P < 0.001), had more cardiogenic shock (6 of 75, vs 0 of 125, P < 0.001) and mitral valve surgery (60 of 75 vs 69 of 125, P < 0.001). Propensity matching yielded 60 pairs of TVI cases and TVN controls. Matched groups were comparable in age (TVI = 67 ± 13 vs TVN 68 ± 14 years, P = 0.67), cardiogenic shock (2 vs 0, P = 0.50), and mitral valve surgery (15 each, P = 1.0). Operative mortality was 2 of 60 in TVI vs 10 of 60 TVN (P = 0.27). Median follow-up was 4.4 years. Follow-up rates of New York Heart Association class III-IV were similar (12 of 60 for TVI vs 16 of 60 TVN, P = 0.52). Kaplan-Meier analysis indicated improved event-free survival for TVI patients (6 years, 95% CI: 4.8-7.2 years vs 8 years, 95% CI: 6.7-9.3 years for TVN, P = 0.030). There was a trend towards increased TR at follow-up in patients with valve repair alone vs annuloplasty (P = 0.15). TV surgery was performed more often in higher-risk patients. Matched case-control analyses showed TVI was associated with improved midterm outcomes. Our data suggest that annuloplasty was preferable to TV repair alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Emerging Transcatheter Options for Tricuspid Regurgitation

    PubMed Central

    Kalra, Ankur; Uberoi, Angad S.; Latib, Azeem; Khera, Sahil; Little, Stephen H.; Bhatt, Deepak L.; Reardon, Michael J.; Kleiman, Neal S.; Barker, Colin M.

    2017-01-01

    Tricuspid regurgitation (TR) presents as either primary valve pathology or secondary to pulmonary or left-sided heart disease. Severe TR portends a worse prognosis independent of age, right ventricular size and function, severe left ventricular dysfunction, and increased pulmonary arterial pressures. Surgical treatment for TR has mostly been limited to patients undergoing mitral valve repair since those at high surgical risk are not candidates for traditional TR surgery. For these patients, minimally invasive techniques could be of great benefit, yet these techniques have been slow to develop because of the various anatomic and physiological aspects of the tricuspid valve apparatus. Several promising new techniques are currently undergoing clinical investigation, including caval valve implantation, percutaneous tricuspid annuloplasty techniques (Trialign, TriCinch, Cardioband), edge-to-edge repair with the MitraClip system, the FORMA device, and the GATE tricuspid Atrioventricular Valved Stent. Further evaluation of their safety and long-term efficacy is warranted prior to commercial approval and widespread adoption. PMID:29743996

  11. Tricuspid valve replacement: postoperative and long-term results.

    PubMed

    Van Nooten, G J; Caes, F; Taeymans, Y; Van Belleghem, Y; François, K; De Bacquer, D; Deuvaert, F E; Wellens, F; Primo, G

    1995-09-01

    A series of 146 consecutive patients who underwent tricuspid valve replacement at the University Brugmann Hospital between 1967 and 1987 was reviewed. Mean age at operation was 51.4 years (+/- 12.1 years). Different types of prostheses were implanted including porcine and bovine pericardial bioprostheses and older and bileaflet mechanical valves. Most patients were severely disabled by their cardiac disease before operation, with 30.1% in New York Heart Association functional class III and 69.9% in class IV. Operative mortality and hospital mortality rates (30 days) were high (16.4%). Incremental risk factors for hospital death included icterus (p < 0.005), preoperative hepatomegaly (p = 0.012), and New York Heart Association functional class IV (p = 0.013). Multivariate analysis only selected preoperative icterus (p < 0.01) as being independently significantly related to hospital mortality. The hospital survivors were followed up for a median of 94 months. A complete follow-up was available for all patients except two for 30 months or more. At 30 months the only two significant parameters were the type of myocardial protection (p = 0.024) and the year of operation (before 1977 or after [precardioplegia era or after], p = 0.011). There were 70 late deaths during the entire follow-up period. The univariate (log-rank statistics) incremental risk factor for late death was the type of tricuspid prosthesis (Smeloff-Cutter and Kay-Shiley versus St. Jude Medical versus bioprosthesis) (p = 0.04). A trend was observed for the type of operative myocardial protection (normothermia and coronary perfusion) (p = 0.06) and preoperative New York Heart Association functional class IV (p = 0.055). Actuarial survival was 74% at 60 months and 23.4% at 180 months. Cumulative follow-up added up to 1015 patient-years. In a more detailed analysis of the effect on survival of the type of tricuspid prosthesis, a significant difference was observed between the bioprostheses and some older

  12. Simultaneous aortic and tricuspid valve rupture after fall injury

    PubMed Central

    Sabzi, Feridoun; Niazi, Mojtaba; Ahmadi, Alireza

    2013-01-01

    Abstract: This case study concerns a patient with disruption of both tricuspid and aortic valves: a previously healthy, adult man, who sustained a 5-meter fall from a building under construction. The mechanism of the injury was acceleration and deceleration, acting in two different phases of the cardiac cycle, i.e. systole and diastole. Simultaneous occurrence of these injuries is exceedingly rare and in a careful literature review, we did not find any such combination of injury. The possible mechanisms of this injury, as well as surgical techniques are discussed. PMID:23511124

  13. Simultaneous aortic and tricuspid valve rupture after fall injury.

    PubMed

    Sabzi, Feridoun; Niazi, Mojtaba; Ahmadi, Alireza

    2013-07-01

    This case study concerns a patient with disruption of both tricuspid and aortic valves: a previously healthy, adult man, who sustained a 5-meter fall from a building under construction. The mechanism of the injury was acceleration and deceleration, acting in two different phases of the cardiac cycle, i.e. systole and diastole. Simultaneous occurrence of these injuries is exceedingly rare and in a careful literature review, we did not find any such combination of injury. The possible mechanisms of this injury, as well as surgical techniques are discussed.

  14. A modified repair technique for tricuspid incompetence in Ebstein's anomaly.

    PubMed

    Hetzer, R; Nagdyman, N; Ewert, P; Weng, Y G; Alexi-Meskhisvili, V; Berger, F; Pasic, M; Lange, P E

    1998-04-01

    A modified technique for tricuspid valve repair in Ebstein's anomaly restructures the valve mechanism at the level of the true tricuspid anulus by using the most mobile leaflet for valve closure without plication of the atrialized chamber. Midterm results of this therapeutic approach for patients with Ebstein's anomaly and tricuspid valve incompetence are reported. Between October 1988 and April 1997, the incompetent tricuspid valve was repaired with our technique in 19 patients (12 female, 7 male; 2 to 54 years, mean 21 years). The indication for operation was congestive heart failure of various degrees in all patients. Tricuspid incompetence was grade II in two patients, grade III in 14, and grade IV in three. Associated congenital malformations were simultaneously repaired (interatrial communication in 18, ventricular septal defect in two, pulmonary stenosis in two, mitral valve prolapse in one). Follow-up ranged between 10 and 103 months (median 28 months) and was complete for all patients. There were no operative deaths. One patient with active endocarditis and pulmonary abscess died 2 months after the operation of recurrent sepsis; there were no late deaths. During follow-up, New York Heart Association functional class improved from 2.8 before the operation to 1.9 without recurrent cyanosis, and tricuspid incompetence decreased from a mean grade of 3.1 to one of 0.9, without any echocardiographic deterioration of the tricuspid valve function or right ventricular dilation. Our technique allows tricuspid valve repair in patients with Ebstein's anomaly, even in cases usually reserved for primary valve replacement, without late functional deterioration.

  15. Diastolic mitral and tricuspid regurgitation by Doppler echocardiography in patients with atrioventricular block: new insight into the mechanism of atrioventricular valve closure.

    PubMed

    Schnittger, I; Appleton, C P; Hatle, L K; Popp, R L

    1988-01-01

    The purpose of this study was to prospectively determine the incidence of diastolic mitral and tricuspid regurgitation in atrioventricular (AV) block using Doppler echocardiography. The temporal relation between mitral and tricuspid diastolic insufficiency and the diastolic murmur recorded in patients with complete heart block was also investigated. Twenty-two consecutive patients with AV block (referred to the Echo-Doppler laboratory for routine clinical studies), aged 18 to 87 years, were enrolled in the study. Eleven patients had third degree AV block and a ventricular-inhibited (VVI) pacemaker, two patients had second degree AV block, seven patients had first degree AV block, one patient had blocked premature atrial complexes and one patient had atrial flutter with 4:1 AV block. Diastolic mitral regurgitation was detected in 20 patients, and diastolic tricuspid regurgitation in 21. A mid-diastolic murmur was detected in all patients except in the three youngest. The murmur occurred before diastolic regurgitation and coincided with peak forward flow through the AV valve after atrial contraction. M-mode mitral valve echocardiograms obtained in nine patients demonstrated near closure of some portions of the mitral valve after atrial contraction. Effective closure of the valve, however, did not occur unless ventricular systole supervened. In conclusion, diastolic mitral and tricuspid regurgitation are almost universally present in patients with AV block and are associated with a diastolic murmur. The murmur coincides with forward AV valve flow. Diastolic regurgitation is silent. Effective AV valve closure is not established until ventricular systole occurs, as demonstrated by M-mode echocardiographic recording of the mitral valve.

  16. Mild-to-moderate functional tricuspid regurgitation in patients undergoing mitral valve surgery.

    PubMed

    Ro, Sun Kyun; Kim, Joon Bum; Jung, Sung Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2013-11-01

    The decision to repair mild-to-moderate functional tricuspid regurgitation (TR) during mitral valve surgery remains controversial. We evaluated the effects of tricuspid valve (TV) repair for functional mild-to-moderate TR during mitral valve surgery. We enrolled 959 patients with mild-to-moderate functional TR who underwent mitral valve surgery with (repair group n = 431) or without (control group n = 528) concomitant TV repair from January 1994 to September 2010. There were no significant differences in early mortality or major morbidity rates. Median follow-up was 64.8 months (range, 0.03-203.6 months). After adjustment for baseline characteristics using a propensity score adjustment model, the repair group had similar risks for TV reoperation (hazard ratio [HR], 0.46; 95% confidence interval [CI], 0.10-2.07; P = .31); congestive heart failure (HR, 1.12; 95% CI, 0.37-3.36; P = .84); death (HR, 1.41; 95% CI, 0.82-2.42; P = .22); and the composite of death, TV reoperation, and congestive heart failure (HR, 1.24; 95% CI, 0.76-2.03; P = .39) compared with the control group. On multivariate Cox-regression analysis, old age, atrial fibrillation without a Maze procedure, diabetes mellitus, chronic renal failure, poor left ventricular ejection fraction, and redo surgery emerged as significant independent risk factors for the composite outcome of death, TV reoperation, and congestive heart failure. Early or late clinical benefits of concomitant TV repair for mild-to-moderate TR during mitral valve surgery were uncertain through a long-term follow-up of 959 patients. Several preoperative factors and the performance of Maze procedure for AF seem to be more important than TV repair in overall clinical outcomes. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  17. Transatrial Intrapericardial Tricuspid Annuloplasty

    PubMed Central

    Rogers, Toby; Ratnayaka, Kanishka; Sonmez, Merdim; Franson, Dominique N.; Schenke, William H.; Mazal, Jonathan R.; Kocaturk, Ozgur; Chen, Marcus Y.; Faranesh, Anthony Z.; Lederman, Robert J.

    2015-01-01

    OBJECTIVES This study sought to demonstrate transcatheter deployment of a circumferential device within the pericardial space to modify tricuspid annular dimensions interactively and to reduce functional tricuspid regurgitation (TR) in swine. BACKGROUND Functional TR is common and is associated with increased morbidity and mortality. There are no reported transcatheter tricuspid valve repairs. We describe a transcatheter extracardiac tricuspid annuloplasty device positioned in the pericardial space and delivered by puncture through the right atrial appendage. We demonstrate acute and chronic feasibility in swine. METHODS Transatrial intrapericardial tricuspid annuloplasty (TRAIPTA) was performed in 16 Yorkshire swine, including 4 with functional TR. Invasive hemodynamics and cardiac magnetic resonance imaging (MRI) were performed at baseline, immediately after annuloplasty and at follow-up. RESULTS Pericardial access via a right atrial appendage puncture was uncomplicated. In 9 naïve animals, tricuspid septal-lateral and anteroposterior dimensions, the annular area and perimeter, were reduced by 49%, 31%, 59%, and 24% (p < 0.001), respectively. Tricuspid leaflet coaptation length was increased by 53% (p < 0.001). Tricuspid geometric changes were maintained after 9.7 days (range, 7 to 14 days). Small effusions (mean, 46 ml) were observed immediately post-procedure but resolved completely at follow-up. In 4 animals with functional TR, severity of regurgitation by intracardiac echocardiography was reduced. CONCLUSIONS Transatrial intrapericardial tricuspid annuloplasty is a transcatheter extracardiac tricuspid valve repair performed by exiting the heart from within via a transatrial puncture. The geometry of the tricuspid annulus can interactively be modified to reduce severity of functional TR in an animal model. PMID:25703872

  18. Tricuspid valve repair with Dacron band versus DeVega or segmental annuloplasty. Hospital outcome and short term results.

    PubMed

    Abdelgawad, Ahmed; Ramadan, Mona; Arafat, Heba; Abdel Aziz, Ahmed

    2017-12-01

    The purpose of this study was to compare the hospital outcome and short term results of tricuspid valve (TV) repair with three repair techniques for functional tricuspid regurgitation (TR), namely, flexible Dacron band, DeVega and segmental annuloplasty. A total of 60 patients underwent TV repair at National Heart Institute from January 2013 to November 2014, of which 20 had DeVega procedure (DV), 20 had a segmental annuloplasty (SA) procedure and 20 had a Dacron band (DB) procedure. Concomitant procedures done for rheumatic left sided valve pathology consisted of mitral valve replacement in 70% of patients, and double valve replacement in 30% of patients. Clinical and echocardiographic follow-up data were obtained. Follow-up was 100% complete and was concluded after one year. All demographic criteria and preoperative characteristics of the three studied groups were comparable except for preoperative right ventricular (RVEDD) size that was significantly bigger in Dacron band group as compared to the other two groups (3.18 ± 0.43 cm compared to 3.00 ± 0.33 cm (DV) and to 2.88 ± 0.35 cm (SA), p value of (0.045)). Similarly, all operative and postoperative criteria were comparable among the study groups. Noticeably, (RVEDD) size remodeled better postoperatively in (DB) group as compared to the other two groups, (2.54 ± 0.26 cm compared to 2.83 ± 0.311 cm (DV) and to 2.72 ± 0.29 cm (SA), mean difference values were group (0.64 ± 0.47 cm) for (DB) compared to (0.18 ± 0.29 cm) for (DV) or to (0.16 ± 0.45 cm) for (SA) with p value of 0.000. The majority of patients in each group did not have tricuspid regurgitation (TR) or mild degree (+1) of (TR) on discharge. After one year of follow-up, most of the patient had either no regurgitation or grade (+1 TR). Two patients (10%) in DV group and one patient (5%) in SA group had (+3 TR). There was no statistical significance in the incidence of hospital mortality, only one patient died in DB

  19. Long-term outcomes of tricuspid annuloplasty for functional tricuspid regurgitation associated with degenerative mitral regurgitation: suture annuloplasty versus ring annuloplasty using a flexible band.

    PubMed

    Murashita, Takashi; Okada, Yukikatsu; Kanemitsu, Hideo; Fukunaga, Naoto; Konishi, Yasunobu; Nakamura, Ken; Koyama, Tadaaki

    2014-01-01

    We investigated the long-term outcomes of suture/ring tricuspid valve annuloplasty for functional tricuspid regurgitation associated with degenerative mitral regurgitation. We retrospectively reviewed patients who underwent flexible ring tricuspid valve annuloplasty (n = 120) or suture tricuspid valve annuloplasty (n = 42) for functional tricuspid regurgitation concomitant with surgery for degenerative mitral regurgitation (mean follow-up duration, 5.3 ± 5.1 years). The mean age of patients was 62.5 ± 13.1 years. Thirty-day mortality was zero in the suture group, and 0.8% in the ring group. Tricuspid regurgitation grade at discharge was lower in the ring group ( p = 0.002). No difference was observed between survival and freedom from major cardiac/cerebrovascular adverse events between the groups. However, freedom from ≥moderate tricuspid regurgitation was higher in the ring group (Log-rank p = 0.003). From univariate analysis, the risk factors for ≥moderate TR were suture annuloplasty and preoperative tricuspid regurgitation grade. No reoperation for recurrent tricuspid regurgitation occurred in either group because symptoms experienced by patients with recurrent tricuspid regurgitation were relatively insignificant. Concomitant tricuspid annuloplasty using flexible bands offered improved durability than suture annuloplasty for preventing postoperative tricuspid regurgitation progression.

  20. Natural history of coexistent tricuspid regurgitation in patients with degenerative mitral valve disease: implications for future guidelines.

    PubMed

    Goldstone, Andrew B; Howard, Jessica L; Cohen, Jeffrey E; MacArthur, John W; Atluri, Pavan; Kirkpatrick, James N; Woo, Y Joseph

    2014-12-01

    The management of coexistent tricuspid regurgitation in patients with mitral regurgitation remains controversial. We sought to define the incidence and natural history of coexistent tricuspid regurgitation in patients undergoing isolated mitral surgery for degenerative mitral regurgitation, as well as the effect of late secondary tricuspid regurgitation on cardiovascular symptom burden and survival. To minimize confounding, analysis was limited to 495 consecutive patients who underwent isolated mitral surgery for degenerative mitral valve disease between 2002 and 2011. Patients with coexistent severe tricuspid regurgitation were excluded because such patients typically undergo concomitant tricuspid intervention. Grade 1 to 3 coexistent tricuspid regurgitation was present in 215 patients (43%) preoperatively. Actuarial freedom from grade 3 to 4 tricuspid regurgitation 1, 5, and 9 years after surgery was 100% ± 0%, 90% ± 2%, and 64% ± 7%, respectively. Older age (P < .001) and grade of preoperative tricuspid regurgitation (P = .006) independently predicted postoperative progression of tricuspid regurgitation on multivariable analysis. However, when limited to patients with mild or absent tricuspid regurgitation, indexed tricuspid annular diameter was the only significant risk factor for late tricuspid regurgitation (P = .04). New York Heart Association functional class and long-term survival did not worsen with development of late secondary tricuspid regurgitation (P = .4 and P = .6, respectively). However, right ventricular dysfunction was significantly more common in patients with more severe late tricuspid regurgitation (P = .007). Despite durable correction of degenerative mitral regurgitation, less than severe tricuspid regurgitation is likely to progress after surgery if uncorrected. Given the low incremental risk of tricuspid annuloplasty, a more aggressive strategy of concomitant tricuspid repair may be warranted. Copyright © 2014 The American Association

  1. Catheter-based tricuspid valve replacement: first experimental data of a newly designed bileaflet stent graft prosthesis.

    PubMed

    Lausberg, Henning F; Gryszkiewicz, Rafal; Kuetting, Maximilian; Baumgaertner, Moritz; Centola, Marcos; Wendel, Hans-Peter; Nowak-Machen, Martina; Schibilsky, David; Kruger, Tobias; Schlensak, Christian

    2017-07-01

    Moderate or severe degree tricuspid valve regurgitation (TVR) is associated with high rates of morbidity and mortality. Surgical correction as the only therapeutic option offers unsatisfactory results. Recently, several interventional procedures have been introduced clinically in a limited cohort. We present our initial experiments with an innovative interventional valved stent graft for treatment of TVR. A newly designed porcine pericardium-covered nitinol stent graft with a lateral bicuspid valve was adapted to size in a cadaver study. After haemodynamic testing in an ex vivo perfusion setup, vascular access, valve delivery and function were investigated in an ovine animal model ( n  = 7). The device was implanted successfully in all animals. Vascular access was established surgically via the femoral vein without any vascular complications. Angiography demonstrated the correct position of the device with proper sealing of both venae cavae in 6 animals. In 1 extremely large animal, the position of the device was considered too cranial but still acceptable. Correct valve function was verified in all animals by both angiography and echocardiography. There were no persistent arrhythmias other than during valve implant. All animals survived the implant procedure and were sacrificed electively. This study demonstrated that this new valved stent graft could be delivered safely with correct positioning and valve function in this ovine model. Further long-term studies in animals implanted with the device after creation of tricuspid regurgitation are necessary to prove the haemodynamic benefit of this procedure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Recent advances in managing tricuspid regurgitation

    PubMed Central

    Del Forno, Benedetto; Lapenna, Elisabetta; Dalrymple-Hay, Malcom; Taramasso, Maurizio; Castiglioni, Alessandro; Alfieri, Ottavio; De Bonis, Michele

    2018-01-01

    Isolated tricuspid valve surgery is usually carried out with very high morbidity and mortality given the complexity of the affected patients. In light of this, trans-catheter tricuspid valve interventions have been emerging as an attractive alternative to surgery over the last few years. Although feasibility has been shown with a number of devices, clinical experience remains preliminary and associated with significant clinical and technical challenges. Here we describe currently available trans-catheter treatment options for severe tricuspid regurgitation implanted in different locations. PMID:29636903

  3. Transcatheter Therapies for Treating Tricuspid Regurgitation.

    PubMed

    Rodés-Cabau, Josep; Hahn, Rebecca T; Latib, Azeem; Laule, Michael; Lauten, Alexander; Maisano, Francesco; Schofer, Joachim; Campelo-Parada, Francisco; Puri, Rishi; Vahanian, Alec

    2016-04-19

    Tricuspid valve (TV) disease has been relatively neglected, despite the known association between severe tricuspid regurgitation (TR) and mortality. Few patients undergo isolated tricuspid surgery, which remains associated with high in-hospital mortality rates, particularly in patients with prior left-sided valve surgery. Patients with severe TR are often managed medically for years before TV repair or replacement. Current guidelines recommend TV repair in the presence of a dilated tricuspid annulus at the time of a left-sided valve surgical intervention, even if regurgitation is mild. This proposed algorithm aims to prevent the inevitable progression to severe TR and the need for a second surgical intervention. Recently, novel transcatheter treatment options were developed for treating patients with severe TR and right heart failure with prohibitive surgical risk. Here we describe currently available transcatheter treatment options for severe TR implanted at different levels: the junction between vena cavae and right atrium; the tricuspid annulus; or between TV leaflets, improving coaptation. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Cardiac Computed Tomography and Magnetic Resonance Imaging in the Evaluation of Mitral and Tricuspid Valve Disease: Implications for Transcatheter Interventions.

    PubMed

    Naoum, Christopher; Blanke, Philipp; Cavalcante, João L; Leipsic, Jonathon

    2017-03-01

    Transcatheter interventions to treat mitral and tricuspid valve disease are becoming increasingly available because of the growing number of elderly patients with significant comorbidities or high operative risk. Thorough clinical and imaging evaluation in these patients is essential. The latter involves both characterization of the mechanism and severity of valvular disease as well as determining the hemodynamic consequences and extent of ventricular remodeling, which is an important predictor of future outcomes. Moreover, an assessment of the suitability and risk of complications associated with device-specific therapies is also an important component of the preprocedural evaluation in this cohort. Although echocardiography including 2-dimensional and 3-dimensional methods has an important role in the initial assessment and procedural guidance, cross-sectional imaging, including both computed tomographic imagning and cardiac magnetic resonance imaging, is increasingly being integrated into the evaluation of mitral and tricuspid valve disease. In this review, we discuss the role of cross-sectional imaging in mitral and tricuspid valve disease, primarily valvular regurgitation assessment, with an emphasis on the preprocedural evaluation and implications for transcatheter interventions. © 2017 American Heart Association, Inc.

  5. Visualization of traumatic tricuspid insufficiency by three-dimensional echocardiography.

    PubMed

    Nishimura, Kazuhisa; Okayama, Hideki; Inoue, Katsuji; Saito, Makoto; Nagai, Takayuki; Suzuki, Jun; Ogimoto, Akiyoshi; Ohtsuka, Tomoaki; Higaki, Jitsuo

    2010-01-01

    A 19-year-old male was admitted to the emergency room of our hospital after a motor vehicle accident. During his first physical examination, a holosystolic murmur was heard at the fourth left parasternal border. Transthoracic echocardiography showed severe tricuspid insufficiency, but the cause of tricuspid insufficiency was unclear. Therefore, three-dimensional echocardiography was performed and demonstrated flail anterior, posterior and septal leaflets of the tricuspid valve. The diagnosis was tricuspid insufficiency due to papillary muscle rupture secondary to chest blunt trauma. Surgical repair of the tricuspid valve was performed in this patient. After surgery, the signs and symptoms of right ventricular heart failure were relieved. In this case, three-dimensional echocardiography was very useful for the evaluation of spatial destruction of the tricuspid valve and papillary muscle. 2009 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  6. [Reconstructive surgery of the mitral and tricuspid valves with a Cosgrove-Edwards flexible ring].

    PubMed

    Pugliese, P; Pantani, P; Lusa, A M; Nuti, R; Bongiovanni, M; Conti, F; Biasi, C; Pigini, F; Palmisano, D

    2000-04-01

    Mitral and tricuspid valve asymmetric annular dilation represents the most important mechanism which produces insufficiency. Recent computerized in vitro and in vivo three-dimensional models have been developed in order to better understand the competing factors (annular dilation, displacement of papillary muscles, left and right ventricular geometry). The leading cause of mitral and tricuspid competence is a sphincteric action of both annuli, during systole and diastole, the loss of which produces asymmetric dilation and therefore the absence of cusp coaptation. The Cosgrove-Edwards dynamic ring corrects, alone or in combination with other procedures on the valves, this patho-anatomic feature in a physiological way by restoring the normal annular dimensions and the sphincteric movements during the cardiac cycle. Between June 1998 and May 1999, 30 adult patients underwent mitral (n = 20, Group I) or tricuspid valve repair (n = 10, Group II). Regurgitation was due to a degenerative disease in 13 Group I patients and to ischemic (n = 3), congenital (n = 2) or dilated cardiomyopathy (n = 2) in the others. In Group II the leading cause of insufficiency was functional regurgitation in 7 patients and organic in 3. Associated procedures were carried out in 4 Group I patients and in all Group II patients. Regurgitation was evaluated by transesophageal echocardiography before, during and 3 months after operation. The maximal regurgitant area (MRA) and the grade of insufficiency were evaluated using the equation: MRA < 2 cm2 = grade 0, MRA > 2 < 4 cm2 = 1+, MRA > 4 < 7 cm2 = grade 2+, MRA > 7 < 10 cm2 = 3+, MRA > 10 cm2 = 4+. The operative mortality was 0%. One Group I patient died 3 months after operation due to bronchopneumonia. No patient was reoperated on for plasty failure in both groups during the follow-up. Mitral insufficiency was absent (grade 0) in 17 Group I patients and mild (grade 1+) in 3 at the end of operation. At 3-month postoperative transesophageal

  7. Therapeutic strategy for functional tricuspid regurgitation in patients undergoing mitral valve repair for severe mitral regurgitation.

    PubMed

    Kitai, Takeshi; Furukawa, Yutaka; Murotani, Kenta; Krittanawong, Chayakrit; Kaji, Shuichiro; Koyama, Tadaaki; Okada, Yukikatsu

    2017-01-15

    The aim of this study was to determine optimal patient selection and selection of a prosthetic ring size for tricuspid valve (TV) repair at the time of mitral valve (MV) repair. We prospectively enrolled 167 consecutive patients undergoing MV repair. TV repair was indicated if patients had at least one of the following conditions representing tricuspid annular dilatation: (1) tricuspid regurgitation (TR)≥moderate, (2) history of right heart failure, (3) atrial fibrillation, and (4) pulmonary hypertension. The size of the ring was targeted to a normal-sized systolic tricuspid annuls in relation to the patient's body surface area (BSA). Serial echocardiographic studies were performed preoperatively, at discharge, and at 1, 3, and 5years postoperatively. Overall, 100 (60%) patients required TV repair, while it was not indicated for 67 (40%) patients. During follow-up, 26 patients showed progression or recurrent TR≥moderate. The TR grade at 5years after MV surgery was 0.8±0.9 in patients with TV repair and 0.9±0.7 in those without TV repair (P=0.69). There were no significant differences between patients with and without TV repair in a composite endpoint of death from any cause, re-do MV or TV surgery, and recurrence or progression of TR≥moderate (P=0.46). Patient selection for TV repair considering not only the grade of TR but clinical signs representing tricuspid annular dilatation is feasible at the time of MV repair. TV repair targeting a normal systolic size in relation to the BSA is a simple and reproducible procedure. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Repair of traumatic tricuspid insufficiency via minimally invasive port access.

    PubMed

    Kasahara, Hirofumi; Kudo, Mikihiko; Kawajiri, Hiroyuki; Yozu, Ryohei

    2010-04-01

    We report on a successful tricuspid valve plasty using port-access minimally invasive cardiac surgery (MICS) for severe traumatic tricuspid insufficiency caused by blunt chest trauma suffered 15 years previously. A combination repair procedure, consisting of cleft closures, plication of the anteroseptal commissure, and ring annuloplasty, was necessary to achieve valve competence and proved possible via port access without difficulty. Port-access MICS is an alternative approach for tricuspid valve surgery.

  9. Postoperative tricuspid regurgitation after adult congenital heart surgery is associated with adverse clinical outcomes.

    PubMed

    Lewis, Matthew J; Ginns, Jonathan N; Ye, Siqin; Chai, Paul; Quaegebeur, Jan M; Bacha, Emile; Rosenbaum, Marlon S

    2016-02-01

    Many patients with adult congenital heart disease will require cardiac surgery during their lifetime, and some will have concomitant tricuspid regurgitation. However, the optimal management of significant tricuspid regurgitation at the time of cardiac surgery remains unclear. We assessed the determinants of adverse outcomes in patients with adult congenital heart disease and moderate or greater tricuspid regurgitation undergoing cardiac surgery for non-tricuspid regurgitation-related indications. All adult patients with congenital heart disease and greater than moderate tricuspid regurgitation who underwent cardiac surgery for non-tricuspid regurgitation-related indications were included in a retrospective study at the Schneeweiss Adult Congenital Heart Center. Cohorts were defined by the type of tricuspid valve intervention at the time of surgery. The primary end point of interest was a composite of death, heart transplantation, and reoperation on the tricuspid valve. A total of 107 patients met inclusion criteria, and 17 patients (17%) reached the primary end point. A total of 68 patients (64%) underwent tricuspid valve repair, 8 patients (7%) underwent tricuspid valve replacement, and 31 patients (29%) did not have a tricuspid valve intervention. By multivariate analysis, moderate or greater postoperative tricuspid regurgitation was associated with a hazard ratio of 6.12 (1.84-20.3) for the primary end point (P = .003). In addition, failure to perform a tricuspid valve intervention at the time of surgery was associated with an odds ratio of 4.17 (1.26-14.3) for moderate or greater postoperative tricuspid regurgitation (P = .02). Moderate or greater postoperative tricuspid regurgitation was associated with an increased risk of death, transplant, or reoperation in adult patients with congenital heart disease undergoing cardiac surgery for non-tricuspid regurgitation-related indications. Concomitant tricuspid valve intervention at the time of cardiac surgery should

  10. Tricuspid insufficiency after laser lead extraction.

    PubMed

    Rodriguez, Yasser; Mesa, Julian; Arguelles, Eric; Carrillo, Roger G

    2013-08-01

    The use of laser lead extraction (LLE) to remove pacemaker and implantable cardiac defibrillator leads has become more prevalent in the past decade. Though the procedure is associated with a low rate of complications, LLE still poses some risks to patients. Some reports have suggested an increase in tricuspid insufficiency (TI) associated with LLE. We present a series of patients who underwent both LLE and complete evaluation for TI with echocardiographic techniques. From August 2008 to January 2010, 173 prospective, consecutive patients underwent LLE in a single center. All patients had transesophageal echocardiograms (TEE) during the extraction. Fifty-three patients had tricuspid valve function evaluated a day before the procedure with a transthoracic echocardiogram (TTE), during the procedure with a TEE and 2 days postoperatively with a TTE. All 173 patients experienced no change in tricuspid valve function during the procedure with TEE. Of the 53 patients who underwent a complete TI evaluation, 38 were males (72%) and 15 females (38%), with a mean age of 69.45 ± 14.08. Mean ejection fraction was 35.82 ± 14.72. Three (6%) patients experienced TI after the procedure (two mild and one severe, all with tricuspid valve endocarditis); 16 (30%) patients were found to have TI before LLE that returned to normal valve function during or after the procedure. Thirty-four (64%) patients did not experience any significant change of the tricuspid valve performance after LLE. LLE was not associated with increased TI. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  11. Problem: Heart Valve Stenosis

    MedlinePlus

    ... valve . Learn about the different types of stenosis: Aortic stenosis Tricuspid stenosis Pulmonary stenosis Mitral stenosis Outlook for ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...

  12. Provision of tricuspid valve leaflets by septal papillary muscles in the right ventricle of human and other mammal hearts.

    PubMed

    Jezyk, Damian; Jerzemowski, Janusz; Grzybiak, Marek

    2003-01-01

    Leaflets of the tricuspid valve are provided by tendinous cords extending from the papillary muscles. The situation is complicated with the septal muscles, which generally occur in two groups, one as constant musculus coni arteriosi and the second as other variable septal muscles. We tested whether there is a variability in the provision of the tricuspid valve in different taxonomical groups of mammals. The material examined consisted of 299 hearts of mammals (Primates, Ungulata, Carnivora, Lagomorpha, Rodentia, Marsupialia). The musculus coni arteriosi in the majority of mammals provided only the front leaflet, but among Ungulata and Rodentia it provided simultaneously the front and septal leaflet. The other septal muscles provided the front, septal and even back leaflets. The following regularity was observed: in the hearts of Primates provision of the front leaflet and the front part of the septal leaflet predominated, among Ungulata the muscles provided the middle part of the septal leaflet, but among the other mammals the rest of the septal muscles provided, significantly, the back part of the septal leaflet. Such a provision was characteristic for predators, hares, rodents and marsupials. These circumstances may allow the conclusion to be drawn that there is a taxonomical dependence in the provision of the tricuspid valve in the hearts of the mammals under examination.

  13. Does moderate tricuspid regurgitation require attention during mitral valve surgery?

    PubMed

    Yeates, Alexander; Marwick, Thomas; Deva, Rajeev; Mundy, Julie; Wood, Annabelle; Griffin, Rayleene; Peters, Paul; Shah, Pallav

    2014-01-01

    This study aims to determine whether tricuspid regurgitation (TR) ≥ 2+ requires attention during mitral valve surgery. From April 1999 to 2009, 161 patients undergoing primary, isolated mitral valve procedures were assessed. Preoperative moderate TR (≥2+) was present in 56 of 161 patients and tricuspid valve repair (TVR: ring annuloplasty) was carried out on 22 of 56 patients with TR ≥ 2+. Baseline echocardiogram included TR severity (ASE criteria), TR velocity, estimated right atrial pressure, visual assessment of right ventricular failure and strain. Follow-up was 47 ± 33 months (96% complete); 91 of 161 patients overall (57%) and 44 of 45 patients with TR ≥ 2+ had follow-up echocardiogram. Patients with moderate TR had worse baseline functional class and operative risks, both worst in the non-TVR group. Overall mortality was 15% (n = 23), comprising 2.5% (4/161) 30-day mortality and 12% (9/157) late death. Poorer preoperative TR was associated with worse survival by univariate analysis (P = 0.046), after correction for right ventricular function and pulmonary artery pressure (P = 0.049), age and diabetes (P = 0.041). Despite lower risk of TR ≥ 2+ with TVR, 5-year survival was 42%, which was less than TR < 2+ and that of non-TVR group (90%, P = 0.003). Improvement in overall functional class (NYHA) was better in the non-TVR group (TVR: preoperative 2.1 ± 1.5; post-operative 1.2 ± 1.1 (P = 0.02) versus non-TVR: preoperative 1.8 ± 1.4, post-operative 1.2 ± 0.9 (P < 0.0001)). There was no difference in quality of life (QOL) indices (SF-36 questionnaire) at follow-up between patients with TR < 2+ and TR ≥ 2+ preoperatively, or across all levels of TR before or after surgical repair. Preoperative TR ≥ 2+, non-TVR group had more favourable functional class and mid-term survival with comparable QOL and echocardiographic parameters to the TVR group. © 2013 The Authors. ANZ Journal of Surgery © 2013 Royal Australasian College of Surgeons.

  14. Effects of a 3D segmental prosthetic system for tricuspid valve annulus remodelling on the right coronary artery: a human cadaveric coronary angiography study.

    PubMed

    Riki-Marishani, Mohsen; Gholoobi, Arash; Sazegar, Ghasem; Aazami, Mathias H; Hedjazi, Aria; Sajjadian, Maryam; Ebrahimi, Mahmoud; Aghaii-Zade Torabi, Ahmad

    2017-09-01

    A prosthetic system to repair secondary tricuspid valve regurgitation was developed. The conceptual engineering of the current device is based on 3D segmental remodelling of the tricuspid valve annulus in lieu of reductive annuloplasty. This study was designed to investigate the operational safety of the current prosthetic system with regard to the anatomical integrity of the right coronary artery (RCA) in fresh cadaveric human hearts. During the study period, from January to April 2016, the current prosthetic system was implanted on the tricuspid valve annulus in fresh cadaveric human hearts that met the study's inclusion criteria. The prepared specimens were investigated via selective coronary angiography of the RCA in the catheterization laboratory. The RCA angiographic anatomies were categorized as normal, distorted, kinked or occluded. Sixteen specimens underwent implantation of the current prosthetic system. The mean age of the cadaveric human hearts was 43.24 ± 15.79 years, with vehicle accident being the primary cause of death (59%). A dominant RCA was noticed in 62.5% of the specimens. None of the specimens displayed any injury, distortion, kinking or occlusion in the RCA due to the implantation of the prostheses. In light of the results of the present study, undertaken on fresh cadaveric human heart specimens, the current segmental prosthetic system for 3D remodelling of the tricuspid valve annulus seems to be safe vis-à-vis the anatomical integrity of the RCA. Further in vivo studies are needed to investigate the functional features of the current prosthetic system with a view to addressing the complex pathophysiology of secondary tricuspid valve regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Vortex dynamics in Patient-Specific Stenotic Tricuspid and Bicuspid Aortic Valves pre- and post- Trans-catheter Aortic Valve Replacement

    NASA Astrophysics Data System (ADS)

    Hatoum, Hoda; Dasi, Lakshmi Prasad

    2017-11-01

    Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.

  16. Surgical management of traumatic tricuspid insufficiency.

    PubMed

    Zhang, Zhiqi; Yin, Kanhua; Dong, Lili; Sun, Yongxin; Guo, Changfa; Lin, Yi; Wang, Chunsheng

    2017-06-01

    This study reviews our experience with traumatic tricuspid insufficiency (TTI) following blunt chest trauma. From January 2010 to June 2016, 10 patients (nine males, mean age 49.0 ± 12.4 years) underwent surgical treatment of TTI following blunt chest trauma. The mean intervals between trauma and diagnosis and between trauma and surgery were 74.1 and 81.8 months, respectively. Preoperatively, all patients exhibited severe tricuspid regurgitation. Five patients underwent tricuspid valve repair, and the remaining patients underwent valve replacement. The mean follow-up duration (with echocardiography) was 29.7 months. There was no early or late death. Seven patients had anterior chordal rupture, two patients had anterior papillary muscle rupture, and one patient had both anterior chordal and anterior leaflet rupture. The median postoperative intensive care unit and hospital stays were 1 and 6 days, respectively. There were no severe postoperative complications. During follow-up, four patients exhibited trivial to mild tricuspid regurgitation, and the remaining six patients exhibited no regurgitation. Surgical treatment of TTI via either valve repair or replacement can be performed with low perioperative morbidity and mortality. Early surgery is recommended for achieving a successful valve repair and preserving right ventricular function. © 2017 Wiley Periodicals, Inc.

  17. Early Feasibility Study of a Transcatheter Tricuspid Valve Annuloplasty: SCOUT Trial 30-Day Results.

    PubMed

    Hahn, Rebecca T; Meduri, Christopher U; Davidson, Charles J; Lim, Scott; Nazif, Tamim M; Ricciardi, Mark J; Rajagopal, Vivek; Ailawadi, Gorav; Vannan, Mani A; Thomas, James D; Fowler, Dale; Rich, Stuart; Martin, Randy; Ong, Geraldine; Groothuis, Adam; Kodali, Susheel

    2017-04-11

    The SCOUT (Percutaneous Tricuspid Valve Annuloplasty System for Symptomatic Chronic Functional Tricuspid Regurgitation) trial is a prospective, single-arm, multicenter, early feasibility study of a novel transcatheter device to plicate the tricuspid annulus (TA) and reduce tricuspid regurgitation (TR). This study tested the feasibility and safety of a novel transcatheter device and assessed its early performance and functional outcomes. Between November 2015 and June 2016, 15 patients with New York Heart Association (NYHA) functional class ≥II and moderate or greater functional TR were enrolled. Primary performance and safety endpoint outcomes were technically successful at 30 days with no reintervention. Echocardiographic measurements (TA diameter, effective regurgitant orifice area [EROA], left ventricular stroke volume [LVSV]) and quality-of-life (QoL) measurements (NYHA functional class, Minnesota Living with Heart Failure Questionnaire [MLHFQ], and 6-min walk test [6MWT]) were performed at baseline and 30 days. All patients (mean 73.2 ± 6.9 years of age, 87% female) underwent successful device implantation with no deaths, strokes, bleeding, tamponade, or valve reintervention. Technical success rate at 30 days was 80%, with 3 single-pledget annular detachments without reintervention. In the remaining 12 patients, there were significant reductions in TA (12.3 ± 3.1 cm 2 to 11.3 ± 2.7 cm 2 , respectively; p = 0.019) and EROA (0.51 ± 0.18 cm 2 vs. 0.32 ± 0.18 cm 2 , respectively; p = 0.020), with significant increase in LVSV (63.6 ± 17.9 ml vs. 71.5 ± 25.7 ml, respectively; p = 0.021). In the intention-to-treat cohort, there were significant improvements in NYHA functional class (≥1 class, p = 0.001), MLHFQ (47.4 ± 17.6 to 20.9 ± 14.8; p < 0.001), and 6MWT (245.2 ± 110.1 to 298.0 m ± 107.6 m; p = 0.008). The 30-day results of the SCOUT trial confirmed the safety of the novel transcatheter device, which reduced TA and EROA, increased LVSV

  18. Acquired tricuspid valve stenosis due to intentionally redundant transvenous lead placement for VDD pacing in two small dogs.

    PubMed

    Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A

    2015-12-01

    Placement of an endocardial VDD pacing lead in small dogs (<12 kg) may necessitate a redundant lead remaining looped in the right atrium for appropriate sensing and pacing. This report documented acquired tricuspid valve stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Advanced mitral-tricuspid disease with severe right ventricular dysfunction: the double-staged approach.

    PubMed

    Jouan, Jérôme; Achouh, Paul; Besson, Laila; Carpentier, Alain; Fabiani, Jean-Noël

    2012-09-01

    Tricuspid valve surgery in the presence of severe right ventricular dysfunction and pulmonary hypertension secondary to mitral valve stenosis is associated with poor early outcomes. We report the case of a young patient, presenting with severe chronic mitral-tricuspid disease responsible for long-lasting pulmonary hypertension and altered right ventricular function, who initially underwent mitral valve replacement and 7 days later the correction of her tricuspid insufficiency. This 2-staged approach permitted progressive reduction of pulmonary pressure and partial right ventricular remodeling before closing the systolic release valve of the right ventricle represented by tricuspid regurgitation. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Current Treatment Strategies for Tricuspid Regurgitation.

    PubMed

    Al-Hijji, Mohammed; Fender, Erin A; El Sabbagh, Abdallah; Holmes, David R

    2017-09-14

    Tricuspid regurgitation is common; however, recognition and diagnosis, clinical outcomes, and management strategies are poorly defined. Here, we will describe the etiology and natural history of tricuspid regurgitation (TR), evaluate existing surgical outcomes data, and review the evolving field of percutaneous interventions to treat TR. Previously, the only definitive corrective therapy for TR was surgical valve repair or replacement which is associated with significant operative mortality. Advances in percutaneous valve repair techniques are now being translated to the tricuspid valve. These novel interventions may offer a lower-risk alternative treatment in patients at increased surgical risk. Significant TR adversely impacts survival. Surgery remains the only proven therapy for treatment of TR and may be underutilized due to mixed outcomes data. Early experience with percutaneous interventions is promising, but large clinical experience is lacking. Further study will be required before these therapies are introduced into broader clinical practice.

  1. [Remote results of plastic operations on the tricuspid valve in patients with cardiac insufficiency at terminal stage].

    PubMed

    Habriielian, A V; Smorzhevs'kyĭ, V I; Onishchenko, V F; Beleĭovych, V V; Topchu, Ie I; Domans'kyĭ, T M; Myroniuk, O I

    2011-07-01

    Comparative analysis of the results of plastic operations performance on a tricuspid valve (TV) in patients, suffering cardiac insufficiency in terminal stage, was conducted. In late postoperative period the indices of intracardial hemodynamics (cardiac output fraction, regurgitation on TV) and clinical features (severity of symptoms, quality of life) after plastic operations, using a support ring, have differed significantly from those after performance of a sutured plasty. The valve function during five years was secured in 91.1% of patients.

  2. Comparison of tricuspid and bicuspid aortic valve hemodynamics under steady flow conditions

    NASA Astrophysics Data System (ADS)

    Seaman, Clara; Ward, James; Sucosky, Philippe

    2011-11-01

    The bicuspid aortic valve (BAV), a congenital valvular defect consisting of two leaflets instead of three, is associated with a high prevalence of calcific aortic valve disease (CAVD). CAVD also develops in the normal tricuspid aortic valve (TAV) but its progression in the BAV is more severe and rapid. Although hemodynamic abnormalities are increasingly considered potential pathogenic contributor, the native BAV hemodynamics remain largely unknown. Therefore, this study aims at comparing experimentally the hemodynamic environments in TAV and BAV anatomies. Particle-image velocimetry was used to characterize the flow downstream of a native TAV and a model BAV mounted in a left-heart simulator and subjected to three steady flow rates characterizing different phases of the cardiac cycle. While the TAV developed a jet aligned along the valve axis, the BAV was shown to develop a skewed systolic jet with skewness decreasing with increasing flow rate. Measurement of the transvalvular pressure revealed a valvular resistance up to 50% larger in the BAV than in the TAV. The increase in velocity between the TAV and BAV leads to an increase in shear stress downstream of the valve. This study reveals strong hemodynamic abnormalities in the BAV, which may contribute to CAVD pathogenesis.

  3. Combining Tricuspid Valve Repair With Double Lung Transplantation in Patients With Severe Pulmonary Hypertension, Tricuspid Regurgitation, and Right Ventricular Dysfunction

    PubMed Central

    Sareyyupoglu, Basar; Bhama, Jay; Bonde, Pramod; Thacker, Jnanesh; Bermudez, Christian; Gries, Cynthia; Crespo, Maria; Johnson, Bruce; Pilewski, Joseph; Toyoda, Yoshiya

    2011-01-01

    Background: Concomitant tricuspid valve repair (TVR) and double lung transplantation (DLTx) has been a surgical option at our institution since 2004 in an attempt to improve the outcome of DLTx for end-stage pulmonary hypertension, severe tricuspid regurgitation, and right ventricle (RV) dysfunction. This study is a review of that single institutional experience. Methods: Consecutive cases of concomitant TVR and DLTx performed between 2004 and 2009 (TVR group, n = 20) were retrospectively compared with cases of DLTx alone for severe pulmonary hypertension without TVR (non-TVR group, n = 58). Results: There was one in-hospital death in the TVR group. The 90-day and 1- and 3-year survival rates for the TVR group were 90%, 75%, and 65%, respectively, which were not significantly different from those for the non-TVR group. The TVR group required less inotropic support and less prolonged mechanical ventilation in the ICU. Follow-up echocardiography demonstrated immediate elimination of both volume and pressure overload in the RV and tricuspid regurgitation in the TVR group. Notably, there was a significantly lower incidence of primary graft dysfunction following transplantation in the TVR group (P < .05). Pulmonary functional improvement shown by an FEV1 increase after 6 months was also significantly better in the TVR group (40% vs 20%, P < .05). Conclusions: Combined TVR and DLTx procedures were successfully performed without an increase in morbidity or mortality and contributed to decreased primary graft dysfunction. In our experience, this combined operative approach achieves clinical outcomes equal or superior to the outcomes seen in DLTx patients without RV dysfunction and severe tricuspid regurgitation. PMID:21700686

  4. Transhepatic implant of a trimmed Melody™ valved stent in tricuspid position in a 1-year-old infant.

    PubMed

    Cools, Bjorn; Rega, Filip; Gewillig, Marc

    2017-02-15

    Percutaneous valved stent implantation is precluded in small infants because large delivery sheaths and large devices. We describe a procedure in a 1-year-old boy in whom a 19 mm Epic™ valve in tricuspid position had become dysfunctional. As the internal diameter of the prosthetic valve was about 16 mm, the only available valve was the Melody™ valved stent. Technical modifications were required to address issues like venous access, the bulky delivery system, and the length of the valved stent. The Melody™ valved stent was surgically trimmed and mounted on a 16 mm Tyshak balloon, access was provided transhepatically through a short 18 Fr sheath. After deployment, the intrahepatic route was sealed with two vascular plugs (8 and 10 mm) in tandem. The procedure was uncomplicated with perfect valve function 18 months after implant. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. A comparison of the clinical, haemodynamic and angiographic features in right ventricular endomyocardial fibrosis and Ebstein's anomaly of the tricuspid valve.

    PubMed

    Balakrishnan, K G; Sapru, R P; Sasidharan, K; Venkitachalam, C G

    1982-01-01

    The clinical, haemodynamic and angiographic features of 18 patients with right ventricular endomyocardial fibrosis (RVEMF) and 8 patients with Ebstein's anomaly of the tricuspid valve (EATV) have been compared. Diagnosis was confirmed by selective angiography. The position of the tricuspid annulus was identified from selective right ventricular angiograms and confirmed by selective right coronary angiography. In 83% of RVEMF patients the tricuspid annulus was displaced to the left of the spine. A false impression of displacement of the tricuspid leaflet can thus be created. However, a tricuspid leaflet displaced away from the tricuspid annulus was found only in patients with EATV. A considerable overlap exists between the wide spectrum of clinical presentations of the two conditions. Helpful distinguishing features that favour EATV were, the presence of a scratchy diastolic murmur and polyphasic QRS complexes in the ECG. Atrial fibrillation in the ECG, and myocardial calcification or pericardial effusion, whenever present, favour RVEMF.

  6. Deformation Differences between Tricuspid and Bicuspid Aortic Valves in Vitro

    NASA Astrophysics Data System (ADS)

    Szeto, Kai; Rodriguez-Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan C.

    2011-11-01

    It has been shown in clinical studies that patients with congenital bicuspid aortic valves (CBAVs) develop degenerative calcification of the leaflets at young ages compared to patients with the normal tricuspid aortic valves (TAVs). It has been hypothesized that the asymmetrical geometry of the leaflets in CBAVs, flow shear stresses (SS), disturbed flow, and excessive strain rate levels are possible causes for the early calcification and stenosis. Central to the validation of this hypothesis is the need to quantify the differences in strain rate levels between the BAVs and TAVs. We simulate the CBAVs by surgically stitching two of the leaflets of a porcine aortic valve together. To quantify strain differences, we performed in-vitro experiments in both trileaflet and bileaflet valves by tracking the motion of small ink dots marked on each leaflet surface. We then used phase-locked stereo photogrammetry to reconstruct at each instant of time the 3D surface of the leaflets and measure the strain rates in both radial and circumferential directions during the whole cardiac cycle. Our results indicate that the total strain rate of the simulated BAVs is about 15 to 20% higher than the normal leaflets of TAVs at systole. In the BAVs' case, the fused leaflet stretches radially up to 25% higher than the reference length. The excessive stretching in both directions in the fused leaflet results in large changes in the flow patterns and associated wall SS.

  7. Mechanical valve obstruction: Review of diagnostic and treatment strategies

    PubMed Central

    Salamon, Jason; Munoz-Mendoza, Jerson; Liebelt, Jared J; Taub, Cynthia C

    2015-01-01

    Prosthetic valve obstruction (PVO) is a rare but feared complication of mechanical valve replacement. Diagnostic evaluation should focus on differentiating prosthetic valve thrombosis (PVT) from pannus formation, as their treatment options differ. History of sub-optimal anti-coagulation and post-op time course to development of PVO are useful clinical characteristics in differentiating thrombus from pannus formation. Treatment of PVT is influenced by the patient’s symptoms, valve location, degree of obstruction and thrombus size and may include thrombolysis or surgical intervention. Alternatively, pannus formation requires surgical intervention. The purpose of this article is to review the pathophysiology, epidemiology, diagnostic approach and treatment options for aortic and mitral valve PVO. PMID:26730292

  8. Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique.

    PubMed

    Hausleiter, Jörg; Braun, Daniel; Orban, Mathias; Latib, Azeem; Lurz, Philipp; Boekstegers, Peter; von Bardeleben, Ralph Stephan; Kowalski, Marek; Hahn, Rebecca T; Maisano, Francesco; Hagl, Christian; Massberg, Steffen; Nabauer, Michael

    2018-04-24

    Severe tricuspid regurgitation (TR) has long been neglected despite its well known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though the device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and variability of tricuspid valve anatomy, echocardiographic visibility of the valve leaflets, and device steering to the tricuspid valve. Furthermore, it remains to be clarified which patients are suitable for a percutaneous tricuspid repair and which features predict a successful procedure. On the basis of the available experience, we describe criteria for patient selection including morphological valve features, a standardized process for echocardiographic screening, and a strategy for clip placement. These criteria will help to achieve standardization of valve assessment and the procedural approach, and to further develop interventional tricuspid valve repair using either currently available devices or dedicated tricuspid edge-to-edge repair devices in the future. In summary, this manuscript will provide guidance for patient selection and echocardiographic screening when considering edge-to-edge repair for severe TR.

  9. Left main coronary artery obstruction by dislodged native-valve calculus after transcatheter aortic valve replacement.

    PubMed

    Durmaz, Tahir; Ayhan, Huseyin; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-08-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement.

  10. Left Main Coronary Artery Obstruction by Dislodged Native-Valve Calculus after Transcatheter Aortic Valve Replacement

    PubMed Central

    Durmaz, Tahir; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-01-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement. PMID:25120396

  11. The Fate of the Tricuspid Valve Following the Transatrial Closure of the Ventricular Septal Defect.

    PubMed

    Giordano, Raffaele; Cantinotti, Massimiliano; Di Tommaso, Luigi; Comentale, Giuseppe; Tozzi, Andrea; Pilato, Emanuele; Iannelli, Gabriele; Palma, Gaetano

    2018-05-17

    The transatrial repair of the ventricular septal defect (VSD) requires an adequate exposure of its rim. We retrospectively evaluated the impact of adopting the tricuspid valve incision (TVI) technique, either with detachment or radial incision, on the postoperative outcome of children undergoing surgical VSD repair. From January 2008 to September 2017 we retrospectively enrolled 141 patients, divided into two groups: 97 patients were subjected to TVI (68.8%) and 44 patients (31.2%) were not subjected to TVI. All patients received an echocardiogram upon discharge from the hospital and after 1 month, 3 months, 6 months and a year from the treatment. No perioperative or late deaths resulted in our dataset. TVI was associated with a slightly longer cardio-pulmonary bypass and cross-clamp time but there were no differences in the surgical outcome between the two groups. Moreover, no differences occurred concerning residual VSD, atrioventricular block or tricuspid regurgitation at discharge. Echocardiograms at follow-up were available for 134 patients (95%) with a median of 5.3 years (range 0.5-9.3) and the degree of tricuspid regurgitation did not differ between groups. No patient required reoperation for tricuspid regurgitation or residual interventricular shunt. Finally, no difference was found even when comparing the two TVI subgroups. TVI should be used whenever intraoperative exposure of VSD is compromised in order to avoid a residual shunt and atrioventricular block. Here we show that this procedure does not significantly compromise the tricuspid function although a large, multicenter, randomized controlled trial is advised to validate this hypothesis. Copyright © 2018. Published by Elsevier Inc.

  12. Tricuspid regurgitation due to chest trauma: an unusual laceration around the annulus of the anterior leaflet.

    PubMed

    Ishii, K; Koga, Y; Maeda, M; Nakamura, K; Sekiya, R; Yonezawa, T; Onitsuka, T; Shibata, K

    1988-01-01

    A 70-year-old male with tricuspid regurgitation due to a blunt chest trauma inflicted 16 years previously underwent prosthetic valve replacement. At surgery, a tear, which produced tricuspid regurgitation, was found around the annulus of the anterior leaflet of the tricuspid valve. Since this area has not been reported as a location for heart trauma-producing tricuspid regurgitation, a possible mechanism of tricuspid regurgitation is discussed in this patient.

  13. Haemodynamic outcome at four-dimensional flow magnetic resonance imaging following valve-sparing aortic root replacement with tricuspid and bicuspid valve morphology

    PubMed Central

    Semaan, Edouard; Markl, Michael; Chris Malaisrie, S.; Barker, Alex; Allen, Bradley; McCarthy, Patrick; Carr, James C.; Collins, Jeremy D.

    2014-01-01

    OBJECTIVE To provide a more complete characterization of aortic blood flow in patients following valve-sparing aortic root replacement (VSARR) compared with presurgical cohorts matched by tricuspid and bicuspid valve morphology, age and presurgical aorta size. METHODS Four-dimensional (4D) flow magnetic resonance imaging (MRI) was performed to analyse three-dimensional (3D) blood flow in the thoracic aorta of n = 13 patients after VSARR with reimplantation of native tricuspid aortic valve (TAV, n = 6) and bicuspid aortic valve (BAV, n = 7). Results were compared with presurgical age and aortic size-matched control cohorts with TAV (n = 10) and BAV (n = 10). Pre- and post-surgical aortic flow was evaluated using time-resolved 3D pathlines using a blinded grading system (0–2, 0 = small, 1 = moderate and 2 = prominent) analysing ascending aortic (AAo) helical flow. Systolic flow profile uniformity in the aortic root, proximal and mid-AAo was evaluated using a four-quadrant model. Further analysis in nine analysis planes distributed along the thoracic aorta quantified peak systolic velocity, retrograde fraction and peak systolic flow acceleration. RESULTS Pronounced AAo helical flow in presurgical control subjects (both BAV and TAV: helix grading = 1.8 ± 0.4) was significantly reduced (0.2 ± 0.4, P < 0.001) in cohorts after VSARR independent of aortic valve morphology. Presurgical AAo flow was highly eccentric for BAV patients but more uniform for TAV. VSARR resulted in less eccentric flow profiles. Systolic peak velocities were significantly (P < 0.05) increased in post-root repair BAV patients throughout the aorta (six of nine analysis planes) and to a lesser extent in TAV patients (three of nine analysis planes). BAV reimplantation resulted in significantly increased peak velocities in the proximal AAo compared with root repair with TAV (2.3 ± 0.6 vs 1.6 ± 0.4 m/s, P = 0.017). Post-surgical patients showed a non-significant trend towards higher systolic flow

  14. Predictive factor of secondary tricuspid regurgitation after aortic valve replacement for aortic stenosis: the importance of myocardial hypertrophy and diastolic dysfunction.

    PubMed

    Igarashi, Takashi; Tanji, Masahiro; Takahashi, Koki; Ishida, Keiichi; Sasaki, Satomi; Yokoyama, Hitoshi

    2017-05-01

    The aim of this study is to determine the predictors of secondary tricuspid regurgitation after aortic valve replacement for aortic stenosis. Seventy-one patients, who underwent aortic valve replacement for aortic stenosis at our institute from January 2006 to July 2011, were divided into two groups: an STR group, which included 15 patients with moderate or greater than moderate secondary tricuspid regurgitation at a follow-up visit and a control group. Echocardiography was performed before surgery, at discharge, and at a late follow-up visit (mean follow-up 36 ± 19 months, range 0-77). Preoperatively, the number of women (p < .01), body surface area (p < .001), and relative wall thickness (0.60 ± 0.15 vs 0.71 ± 0.13, p = .022) showed significant differences between the two groups. At a follow-up visit, moderate or severe mitral regurgitation (p = .0001) and severe diastolic dysfunction (p = .003) showed significant differences between the two groups. In the Cox regression analysis, moderate or severe mitral regurgitation at follow-up (p = .038, hazard ratio 4.394, 95% CI 1.085-17.791) was the only independent predictor of secondary tricuspid regurgitation. This study suggested that preoperative concentric myocardial hypertrophy and diastolic dysfunction were associated with development of the secondary tricuspid regurgitation at late follow-up.

  15. Transcatheter treatment of tricuspid regurgitation by caval valve implantation--experimental evaluation of decellularized tissue valves in central venous position.

    PubMed

    Lauten, Alexander; Laube, Adrian; Schubert, Harald; Bischoff, Sabine; Nietzsche, Sandor; Horstkötter, Kim; Poudel-Bochmann, Bhawana; Franz, Marcus; Lichtenberg, Artur; Figulla, Hans R; Akhyari, Payam

    2015-01-01

    Caval valve implantation has been suggested for transcatheter treatment of severe tricuspid regurgitation (TR). Combining the interventional technique with the promising surgical experience with decellularized valves, we sought to evaluate the functional and structural outcome of decellularized pericardial tissue valves (dTVs) in the low-pressure venous circulation in a chronic model of TR. Sixteen pericardial tissue valves were heterotopically implanted in the inferior and superior vena cava in a sheep model (54-98 kg; median 74.5 kg, n = 8) of severe TR. The devices were assembled using self-expanding nitinol stents and bovine pericardia decellularized by a detergent-based protocol (group dTV; n = 8). Glutaraldehyde-fixed pericardial tissue valves served as control (GaTV, n = 8). After 6 months, device function and structural maturation were analyzed using echocardiographic, histologic, immunohistologic, and electron microscopic approaches. After implantation, cardiac output increased significantly from 3.7 ± 1.1 l/min to 4.8 ± 1.1 l/min (P < 0.05) and competent valve function was verified by angiography. At 6 months, angiographic and echocardiographic evaluation revealed moderate to severe regurgitation in all GaTV. In contrast, five of the eight dTVs functioned well with only minor regurgitation. In these animals, autopsy revealed preserved valve structure with tender leaflets without signs of thrombosis or calcification. Conversely, GaTV showed severe degeneration with large calcification areas. Microscopic and histologic analysis confirmed endothelial repopulation in both valve types. However, additional interstitial reseeding was observed in decellularized valves. In the venous circulation in severe TR, decellularized valves show superior functional performance compared to Ga-fixed tissue valves. Macroscopic and microscopic analyses suggest preserved structural integrity and advanced endothelial and interstitial repopulation with

  16. Concomitant tricuspid valve repair or replacement during left ventricular assist device implant demonstrates comparable outcomes in the long term.

    PubMed

    Deo, Salil V; Hasin, Tal; Altarabsheh, Salah E; McKellar, Stephen H; Shah, Ishan K; Durham, Lucian; Stulak, John M; Daly, Richard C; Park, Soon J; Joyce, Lyle D

    2012-11-01

    Severe tricuspid regurgitation (TR) is present in nearly half the patients undergoing implant of a left ventricular assist device (LVAD) and its correction confers better long-term outcome. To compare the early and late results of tricuspid valve repair (TVrpr) or replacement (TVR) with LVAD implant. Sixty-four from a cohort of 126 patients had a concomitant tricuspid valve procedure; 48 (75%) underwent a TVrpr whereas 16 (25%) had TVR. All preoperative hemodynamic parameters including the mean TR grade (TVrpr; 3.6 vs. TVR; 3.7) were comparable (p = 0.7). The mean TR grade was 1.6 ± 1.5 for the remaining 62 patients who did not have a concomitant tricuspid valve procedure, with 4/62 (6%) having severe TR (p < 0.0001). Cardiopulmonary bypass time was longer for patients undergoing TVR (p = 0.01). There was a significant reduction in right atrial pressure for the entire cohort (p < 0.01) and the postoperative right atrial pressure was not statistically different between TVrpr (13.6 ± 4.6) and TVR (11.6 ± 4.3; p = 0.6. Postoperative intensive care unit stay was comparable as was the duration of inotropic support (p = 0.5) or need for temporary right ventricular mechanical support. In-hospital mortality (12%) was not different between groups. The mean time for LVAD support was 12.3 ± 9.71 months and the last transthoracic echocardiographic examination was performed at mean intervals of 13.8 ± 10.8 months (TVrpr) and 11.8 ± 7.6 months (TVR; p = 0.47). Reduction in TR grade was similar between groups (p = 0.27). Late mortality (p = 1.00) was comparable in both groups. Using log-rank analysis, there was no significant difference in the estimated survival between TVrpr and TVR (p = 0.88). TVrpr repair at the time of LVAD implant is effective in correcting TR even at the end of one year of follow-up. The choice to repair or replace does not affect the clinical outcome. © 2012 Wiley Periodicals, Inc.

  17. Post-traumatic tricuspid insufficiency: a case report.

    PubMed

    Tütün, Ufuk; Aksöyek, Ayşen; Parlar, Ali Ihsan; Cobanoğlu, Adnan

    2011-11-01

    Post-traumatic tricuspid insufficiency is a rare complication of chest trauma. An 18-year-old male patient was injured in a bicycle accident from his abdominal and anterior chest wall. The tear on the inferior diaphragmatic surface of the heart was repaired with primary sutures by the attending surgeon. Eighteen years later, he was admitted to the hospital with severe tricuspid regurgitation (3+/4+). During the operation, the valve was determined unsuitable for repair and was replaced with a bioprosthesis. The hemodynamic aberrations relevant to an isolated tricuspid valve injury are very often well-tolerated. Reconstructive surgery may be possible in the early period. In the late cases, repair is sometimes not feasible due to degeneration of the valvular apparatus. Replacement with a biological prosthesis may give the best long-term results in longstanding cases.

  18. Recurrent Tricuspid Insufficiency

    PubMed Central

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair. In our clinic, 93 patients with functional tricuspid insufficiency underwent surgical tricuspid repair from May 2007 through October 2010. The study was retrospective, and all the data pertaining to the patients were retrieved from hospital records. Functional capacity, recurrent tricuspid insufficiency, and risk factors aggravating the insufficiency were analyzed for each patient. In the medium term (25.4 ± 10.3 mo), the rates of grades 3 and 4 tricuspid insufficiency in the De Vega, modified De Vega, and ring annuloplasty groups were 31%, 23.1%, and 6.1%, respectively. Logistic regression analysis revealed that chronic obstructive pulmonary disease, left ventricular dysfunction (ejection fraction, < 0.50), pulmonary artery pressure ≥60 mmHg, and the De Vega annuloplasty technique were risk factors for medium-term recurrent grades 3 and 4 tricuspid insufficiency. Medium-term survival was 90.6% for the De Vega group, 96.3% for the modified De Vega group, and 97.1% for the ring annuloplasty group. Ring annuloplasty provided the best relief from recurrent tricuspid insufficiency when compared with DeVega annuloplasty. Modified De Vega annuloplasty might be a suitable alternative to ring annuloplasty when rings are not available. PMID:23466680

  19. Pregnancy-induced remodeling of heart valves.

    PubMed

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves. Copyright © 2015 the American Physiological Society.

  20. Obstructive Thebesian valve: anatomical study and implications for invasive cardiologic procedures.

    PubMed

    Ghosh, Sanjib Kumar; Raheja, Shashi; Tuli, Anita

    2014-03-01

    Thebesian valve is the embryological remnant of the right sinoatrial valve, guarding the coronary sinus (CS) ostium. Advanced invasive and interventional cardiac diagnostic and management tools involve cannulation of the CS ostium. The presence of obstructive Thebesian valves has been reported to lead to unsuccessful cannulation of the CS. We studied the morphology of the Thebesian valve and CS ostium to assess the possible impact of these structures on invasive cardiological procedures. One hundred fifty randomly selected human cadaveric heart specimens fixed in 10% formalin were dissected in the customary routine manner. The Thebesian valves were classified according to their shape as semilunar/fenestrated/biconcave band like and according to their composition as membranous/fibromuscular/fibrous/muscular, and the extent to which the valve covered the CS ostium was also noted. An obstructive Thebesian valve that could interfere with the cannulation of the CS was defined as non-fenestrated (semilunar/biconcave band like) and non-membranous (fibromuscular/fibrous/muscular) valves covering >75% of the CS ostium. Thebesian valves were present in 118 (79%) heart specimens, of which 27 (18%) met the criteria of being obstructive. Semilunar was the most common type of Thebesian valve in terms of shape and was observed in 65 (65/118; 55%) hearts. This type was associated with the least mean craniocaudal (7.9±0.6 mm) and mean transverse (6.25±0.6 mm) diameters of the CS ostium. The mean craniocaudal diameter of the CS ostium (9.4±2.1 mm) was significantly larger (p=0.004) than the mean transverse diameter (7.15±1.5 mm) in specimens with Thebesian valves, and the cranial margin of the CS ostium was free from any attachment of the Thebesian valve in all the types observed (in terms of shape). Hence, attempts to direct the tip of the catheter toward the cranial margin of the CS ostium under direct vision may lead to successful cannulation of the same when conventional

  1. Transvenous right ventricular pacing in a patient with tricuspid mechanical prosthesis.

    PubMed

    Sierra, Juan; Rubio, José

    2008-07-09

    We report a patient in whom permanent endocardial pacing was accomplished by passage of the electrode through a mechanical tricuspid valve. Echocardiography study showed a minimal tricuspid regurgitation.

  2. Aortic regurgitation due to fibrous strand rupture in the fenestrated left coronary cusp of the tricuspid aortic valve.

    PubMed

    Irisawa, Yusuke; Itatani, Keiichi; Kitamura, Tadashi; Hanayama, Naoji; Oka, Norihiko; Tomoyasu, Takahiro; Inoue, Nobuyuki; Hayashi, Hidenori; Inoue, Takamichi; Miyaji, Kagami

    2014-01-01

    Fenestration-related massive aortic regurgitation is rare. The underlying mechanism is reported to be rupture of the fenestrated fibrous strand, and most ruptured cords have been reported in the bicuspid valve or in the right coronary cusp of the tricuspid aortic valve. We encountered a rare case of acute aortic regurgitation due to fibrous strand rupture in the fenestrated left coronary cusp. Preoperative echocardiography detected left coronary cusp prolapse, and operative findings revealed rupture of a fibrous strand in the left coronary cusp. For cases such as this, preoperative echocardiography would be useful for appropriate diagnosis.

  3. The "clover technique" as a novel approach for correction of post-traumatic tricuspid regurgitation.

    PubMed

    Alfieri, O; De Bonis, M; Lapenna, E; Agricola, E; Quarti, A; Maisano, F

    2003-07-01

    To describe a novel technique, named "clover," to correct complex post-traumatic tricuspid valve lesions. Five patients with severe post-traumatic tricuspid insufficiency underwent valve reconstruction with the clover technique, a new surgical approach that consists of stitching together the middle point of the free edges of the tricuspid leaflets, producing a clover-shaped valve. The mechanism of tricuspid regurgitation was complex in all patients, and right ventricular function was always moderately to severely depressed. An echocardiographic study was performed after cardiopulmonary bypass, at discharge, and at follow-up. Cardiopulmonary bypass time was 32 +/- 6.3 minutes and crossclamp time was 23 +/- 7.4. There was no hospital mortality or morbidity. Intraoperative transesophageal and predischarge transthoracic echocardiography showed perfect results in all patients. No late deaths occurred. At the latest follow-up, extending to 14.2 months (mean 11.3; median 12.4), all patients were asymptomatic (New York Heart Association class I) with trivial (2 patients) or no residual regurgitation (3 patients) on 2-dimensional echocardiogram. No transvalvular gradient was revealed in any patient. A significant reduction of the right ventricular end-diastolic dimensions was noted as well (from 54 +/- 7.1 mm to 40 +/- 7.5 mm, P <.001). In this preliminary experience, the clover technique increased the feasibility of tricuspid valve repair in case of severe traumatic tricuspid valve insufficiency, leading to very satisfactory mid-term results even in the presence of complex lesions or dilatation and deterioration of the right ventricle.

  4. Outcomes of De Vega versus biodegradable ring annuloplasty in the surgical treatment of tricuspid regurgitation (mid-term results).

    PubMed

    Basel, Halil; Aydin, Unal; Kutlu, Hakan; Dostbil, Aysenur; Karadag, Melike; Odabasi, Dolunay; Aydin, Cemalettin

    2010-08-01

    The aim of this study was to compare De Vega semicircular annuloplasty and a new biodegradable ring annuloplasty technique in patients requiring surgical intervention for tricuspid valve disease with concomitant disease of the mitral valve. Between January 2004 and May 2008, 129 consecutive patients underwent annuloplasty procedures to correct tricuspid valve regurgitation during a concomitant mitral valve operation requiring replacement. Additionally, 24 patients underwent aortic valve replacement (AVR), 11 underwent coronary artery bypass grafting (CABG), 5 underwent AVR plus CABG, 3 underwent mitral valve replacement plus atrial septal defect (ASD) closure, and 2 underwent ASD closure. The patients in this study were assigned to 2 groups: Kalangos ring annuloplasty was performed in 67 patients (group 1), and De Vega semicircular annuloplasty was performed in the remaining 62 patients (group 2). Both tricuspid valve repair techniques produced a low rate of complications; however, the number of patients who developed residual tricuspid regurgitation was significantly lower in group 1. The biodegradable ring annuloplasty technique may be used easily and safely in moderate and severe cases of tricuspid regurgitation; however, larger clinical series are necessary to confirm our promising results.

  5. Tricuspid regurgitation: contemporary management of a neglected valvular lesion.

    PubMed

    Irwin, Richard Bruce; Luckie, Matthew; Khattar, Rajdeep S

    2010-11-01

    Right-sided cardiac valvular disease has traditionally been considered less clinically important than mitral or aortic valve pathology. However, detectable tricuspid regurgitation (TR) is common and recent data suggest that significant TR can lead to functional impairment and reduced survival, particularly in patients with concomitant left-sided valvular disease. The tricuspid valve is a complex anatomical structure and advances in three dimensional echocardiography and cardiac MRI have contributed to a greater understanding of tricuspid valve pathology. These imaging techniques are invaluable in determining the aetiology and severity of TR, and provide an assessment of right ventricular function and pulmonary artery pressure. TR is more prevalent in women and those with a history of myocardial infarction and heart failure. It also occurs in about 10% of patients with rheumatic heart disease. Chronic severe TR may have a prolonged clinical course culminating in the development of fatigue and poor exercise tolerance due to a reduced cardiac output. Approximately 90% of cases of TR are secondary to either pulmonary hypertension or intrinsic right ventricular pathology and about 10% are due to primary tricuspid valve disease. Primary causes such as Ebstein's anomaly, rheumatic disease, myxomatous changes, carcinoid syndrome, endomyocardial fibrosis, and degenerative disease have characteristic morphological features readily identifiable by echocardiography. Ascertaining an accurate right ventricular systolic pressure is important in separating primary from secondary causes as significant TR with a pressure <40 mm Hg implies intrinsic valve disease. Cardiac MRI may be indicated in those with inadequate echocardiographic images and is also the gold standard for the evaluation of right ventricular function and morphology. The assessment of leaflet morphology, annular dimensions, and pulmonary artery pressure are particularly important for determining subsequent

  6. The 'sail sound' and tricuspid regurgitation in Ebstein's anomaly: the value of echocardiography in evaluating their mechanisms.

    PubMed

    Oki, T; Fukuda, N; Tabata, T; Yamada, H; Manabe, K; Fukuda, K; Abe, M; Iuchi, A; Ito, S

    1997-03-01

    We describe a patient with Ebstein's anomaly in whom Doppler echocardiography was used to clarify the mechanism responsible for 'sail sound' and tricuspid regurgitation associated with this condition. Phonocardiography revealed an additional early systolic heart sound, consisting of a first low-amplitude component (T1) and a second high-amplitude component (T2, 'sail sound'). In simultaneous recordings of the tricuspid valve motion using M mode echocardiography and phonocardiography, the closing of the tricuspid valve occurred with T1 which originated at the tip of the tricuspid leaflets, while T2 originated from the body of the tricuspid leaflets. Using color Doppler imaging, the tricuspid regurgitant signal was detected during pansystole, indicating a blue signal during the phase corresponding to T1 and a mosaic signal during the phase corresponding to T2 at end-systole. Thus, 'sail sound' in patients with Ebstein's anomaly is not simply a closing sound of the tricuspid valve, but a complex closing sound which includes a sudden stopping sound after the anterior and/or other tricuspid leaflets balloon out at systole.

  7. [Traumatic tricuspid insufficiency].

    PubMed

    Vayre, F; Richard, P; Ollivier, J P

    1996-04-01

    Traumatic tricuspid insufficiency is a rare condition. The diagnosis is difficult because of the slow progression of this pathology and the presence of more clinically acute lesions. Non-penetrating chest trauma is responsible for 90% of cases. Echocardiography is the investigation of choice for assessing the mechanism of the tricuspid regurgitation and for diagnosing associated lesions. It should be performed systematically in patients with multiple trauma. The surgical indications are difficult to determine and depend on the patients' symptoms and the type of anatomical lesions. It should be undertaken before right ventricular myocardial dysfunction. Several techniques may be used from valvuloplasty to valve replacement mainly with bioprostheses in symptomatic patients.

  8. Direct right ventricular puncture for hemodynamic evaluation of a mechanical tricuspid valve prosthesis: a new indication for an old procedure.

    PubMed

    Gibson, M A; Carell, E S

    1997-11-01

    The advent of transvenous right heart catheterization has relegated direct transthoracic right ventricular puncture largely to the role of "interesting historical footnote." However, in the case of a right ventricle that is "protected" by a mechanical tricuspid valve prosthesis, direct right ventricular puncture represents a reasonable alternative for obtaining accurate hemodynamic information.

  9. Surgical indication for functional tricuspid regurgitation at initial operation: judging from long term outcomes.

    PubMed

    Pozzoli, Alberto; Lapenna, Elisabetta; Vicentini, Luca; Alfieri, Ottavio; De Bonis, Michele

    2016-09-01

    The assessment and management of tricuspid valve disease have evolved substantially during the past several years. Whereas tricuspid stenosis is uncommon, tricuspid regurgitation is frequently encountered and it is most often secondary due to annular dilatation and leaflet tethering from right ventricular remodelling. The indications for tricuspid valve surgery to treat tricuspid regurgitation are several and mainly related to the underlying disease, to the severity of insufficiency and to the right ventricular function. Surgical tricuspid repair has been avoided for years, because of the misleading concept that tricuspid regurgitation should disappear once the primary left-sided problem has been eliminated. Instead, during the last decade, many investigators have reported evidence in favor of a more aggressive surgical approach to functional tricuspid regurgitation, recognising the risk of progressive tricuspid insufficiency in patients with moderate or lesser degrees of tricuspid regurgitation and tricuspid annular dilatation. This concept, along with the long-term outcomes of principal surgical repair techniques are reported and discussed. Last, novel transcatheter therapies have begun to emerge for the treatment of severe tricuspid regurgitation in high-risk patients. Hence, very preliminary pre-clinical and clinical experiences are illustrated. The scope of this review is to explore the anatomic basis, the pathophysiology, the outcomes and the new insights in the management of functional tricuspid regurgitation.

  10. The challenge of preoperative quantification of functional tricuspid regurgitation and of right ventricle function: what information is clinically relevant?

    PubMed

    Hahn, Rebecca T

    2017-10-01

    Functional or secondary tricuspid regurgitation (TR) is the most common etiology of severe TR in the western world. The presence of functional TR, either isolated or in combination with left heart disease is associated with unfavorable natural history however surgical mortality for isolated tricuspid valve interventions remain higher than for any other single valve surgery. Determining the severity of TR remains a controversial area and will continue to evolve as new techniques for assessing this valve as well as the right ventricle, are investigated. The following review will describe tricuspid anatomy, define echocardiographic views for evaluating tricuspid valve and right heart morphology and function, that are relevant to the pre-procedural assessment of functional TR.

  11. Influence of mitral valve repair versus replacement on the development of late functional tricuspid regurgitation.

    PubMed

    Rajbanshi, Bijoy G; Suri, Rakesh M; Nkomo, Vuyisile T; Dearani, Joseph A; Daly, Richard C; Burkhart, Harold M; Stulak, John M; Joyce, Lyle D; Li, Zhuo; Schaff, Hartzell V

    2014-11-01

    To study the determinants of functional tricuspid regurgitation (TR) progression after surgical correction of mitral regurgitation, including the influence of mitral valve (MV) repair (MVr) versus replacement (MVR) for degenerative mitral regurgitation. From January 1995 to January 2006, 747 adults with MV prolapse underwent isolated MVr (n=683) or MVR (n=64; mechanical in 32). The mean age was 60.8 years, and 491 were men (66.0%). Moderate preoperative functional TR was present in 115 (15.4%). The MVR group had a greater likelihood of New York Heart Association class III or IV (75.0% vs 34.4%, P<.001), atrial fibrillation (20.3% vs 8.3%, P=.002), a lower left ventricular ejection fraction (61.0% vs 65.2%, P<.003), and a higher pulmonary artery pressure (50.1 vs 41.2 mm Hg, P=.001). The patients were monitored for a mean of 6.9 years (MVr) or 7.7 years (MVR; P=.075). During late follow-up, no difference was found between the groups in the development of moderately severe or severe TR: 1 to 5 years (3.0% vs 3.3%, P=.91) and >5 years (6.1% vs 6.5%; P=.93). The univariate predictors of severe TR after 5 years were older age (hazard ratio [HR], 1.1; P=.011), female gender (HR, 6.86; P=.005), higher pulmonary artery pressure (HR, 1.05; P=.022), and larger left atrial size (HR, 2.11; P=.035). Two patients (0.26%) who had undergone initial MVr required reoperation for late functional TR. Another 2 patients had had the tricuspid valve addressed concurrent with reoperation for MVr failure. No tricuspid reoperations were required in the MVR group. The risk of TR progression was low after MVr or MVR for MV prolapse. Timely MV surgery before the development of left atrial dilatation or pulmonary hypertension could further decrease the risk of TR progression during follow-up. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. Transcatheter Treatment of Functional Tricuspid Regurgitation Using the Trialign Device

    PubMed Central

    Besler, Christian; Meduri, Christopher U

    2018-01-01

    Functional tricuspid regurgitation (TR) represents an important unmet need in clinical cardiology given its prevalence, adverse prognostic impact and symptom burden associated with progressive right heart failure. Several transcatheter techniques are currently in early clinical testing to provide alternative treatment options for patients deemed unsuitable for tricuspid valve surgery. Amongst them, the TrialignTM device (Mitralign, Inc.) represents a novel percutaneous tricuspid valve annuloplasty technique, which aims to reduce tricuspid annular dilatation in functional TR by delivering and cinching two pledgeted sutures to the posterior portion of the tricuspid annulus via transjugular access. Early clinical data suggest the Trialign technique is safe and feasible, and associated with an improvement in quality-of-life measures. However, further studies are needed to confirm these data in larger cohorts of patients with longer follow up. In addition, future trials need to address the question whether TR reduction with the Trialign and other devices leads to an improvement in the patient`s functional status and prognosis, over and above medical treatment alone. PMID:29593830

  13. Triple valve surgery: a 25-year experience.

    PubMed

    Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen

    2004-09-01

    Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become

  14. Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?

    PubMed

    Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-11-01

    Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.

  15. State-of-the-Art Review of Echocardiographic Imaging in the Evaluation and Treatment of Functional Tricuspid Regurgitation.

    PubMed

    Hahn, Rebecca T

    2016-12-01

    Functional or secondary tricuspid regurgitation (TR) is the most common cause of severe TR in the Western world. The presence of functional TR, either isolated or in combination with left heart disease, is associated with unfavorable natural history. Surgical mortality for isolated tricuspid valve interventions remains higher than for any other single valve surgery, and surgical options for repair do not have consistent long-term durability. In addition, as more patients undergo transcatheter left valve interventions, developing transcatheter solutions for functional TR has gained greater momentum. Numerous transcatheter devices are currently in early clinical trials. All patients require an assessment of valve morphology and function, and transcatheter devices typically require intraprocedural guidance by echocardiography. The following review will describe tricuspid anatomy, define echocardiographic views for evaluating tricuspid valve morphology and function, and discuss imaging requirements for the current transcatheter devices under development for the treatment of functional TR. © 2016 American Heart Association, Inc.

  16. Pathological Investigation of Congenital Bicuspid Aortic Valve Stenosis, Compared with Atherosclerotic Tricuspid Aortic Valve Stenosis and Congenital Bicuspid Aortic Valve Regurgitation

    PubMed Central

    Hamatani, Yasuhiro; Ishibashi-Ueda, Hatsue; Nagai, Toshiyuki; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Fujita, Tomoyuki; Kobayashi, Junjiro; Anzai, Toshihisa

    2016-01-01

    Background Congenital bicuspid aortic valve (CBAV) is the main cause of aortic stenosis (AS) in young adults. However, the histopathological features of AS in patients with CBAV have not been fully investigated. Methods and Results We examined specimens of aortic valve leaflets obtained from patients who had undergone aortic valve re/placement at our institution for severe AS with CBAV (n = 24, CBAV-AS group), severe AS with tricuspid aortic valve (n = 24, TAV-AS group), and severe aortic regurgitation (AR) with CBAV (n = 24, CBAV-AR group). We compared the histopathological features among the three groups. Pathological features were classified using semi-quantitative methods (graded on a scale 0 to 3) by experienced pathologists without knowledge of the patients’ backgrounds. The severity of inflammation, neovascularization, and calcium and cholesterol deposition did not differ between the CBAV-AS and TAV-AS groups, and these four parameters were less marked in the CBAV-AR group than in the CBAV-AS (all p<0.01). Meanwhile, the grade of valvular fibrosis was greater in the CBAV-AS group, compared with the TAV-AS and CBAV-AR groups (both p<0.01). In AS patients, thickness of fibrotic lesions was greater on the aortic side than on the ventricular side (both p<0.01). Meanwhile, thickness of fibrotic lesions was comparable between the aortic and ventricular sides in CBAV-AR patients (p = 0.35). Conclusions Valvular fibrosis, especially on the aortic side, was greater in patients with CBAV-AS than in those without, suggesting a difference in the pathogenesis of AS between CBAV and TAV. PMID:27479126

  17. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    PubMed Central

    Kuwelker, Saatchi Mahesh; Shetty, Devi Prasad; Dalvi, Bharat

    2017-01-01

    Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR) 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR. PMID:28163430

  18. Dynamic cycling in atrial size and flow during obstructive apnoea.

    PubMed

    Pressman, Gregg S; Cepeda-Valery, Beatriz; Codolosa, Nicolas; Orban, Marek; Samuel, Solomon P; Somers, Virend K

    2016-01-01

    Obstructive sleep apnoea (OSA) is strongly associated with cardiovascular disease. However, acute cardiovascular effects of repetitive airway obstruction are poorly understood. While past research used a sustained Mueller manoeuver to simulate OSA we employed a series of gasping efforts to better simulate true obstructive apnoeas. This report describes acute changes in cardiac anatomy and flow related to sudden changes in intrathoracic pressure. 26 healthy, normal weight participants performed 5-6 gasping efforts (target intrathoracic pressure -40 mm Hg) while undergoing Doppler echocardiography. 14 participants had sufficient echocardiographic images to allow comparison of atrial areas during the manoeuver with baseline measurements. Mitral and tricuspid E-wave and A-wave velocities postmanoeuver were compared with baseline in all participants. Average atrial areas changed little during the manoeuver, but variance in both atrial areas was significantly greater than baseline. Further, an inverse relationship was noted with left atrial collapse and right atrial enlargement at onset of inspiratory effort. Significant inverse changes were noted in Doppler flow when comparing the first beat postmanoeuver (pMM1) with baseline. Mitral E-wave velocity increased 9.1 cm/s while tricuspid E-wave velocity decreased 7.0 cm/s; by the eighth beat postmanoeuver (pMM8) values were not different from baseline. Mitral and tricuspid A-wave velocities were not different from baseline at pMM1, but both were significantly higher by pMM8. Repetitive obstructive apnoeas produce dynamic, inverse changes in atrial size and Doppler flow across the atrioventricular valves. These observations have important implications for understanding the pathophysiology of OSA.

  19. Association Of Tricuspid Regurgitation And Severity Of Mitral Stenosis In Patients With Rheumatic Heart Disease.

    PubMed

    Ahmed, Rehan; Kazmi, Nasir; Naz, Farhat; Malik, Saqib; Gillani, Saima

    2016-01-01

    Rheumatic heart disease is a common ailment in Pakistan and Mitral stenosis is its flag bearer Severity of mitral stenosis is the key factor in deciding for mitral valve surgery. This case series study was conducted at Ayub Teaching Hospital .Cases of Rheumatic heart disease with mitral stenosis were diagnosed clinically. 2D echocardiography was used to find severity of mitral stenosis. Data was entered into SPSS-17.0 and results were recorded and analysed. Pearson's two tailed correlation was used to find the correlation between presence of tricuspid regurgitation in patients with severe mitral stenosis, p was <0.05. A total 35 patients with pure mitral stenosis were included in study, out of which 8 were male and 27 were females. Mean age in males was 34.5±15.85 years while in females it was 31±8 years. Twenty-two out of 35 (62.86%) patients had tricuspid regurgitation while 13 out 35 (37.14%) had no tricuspid regurgitation. Mean (MVA) mitral valve area in patients with tricuspid regurgitation was 0.84±0.3 cm2 while mean (MVA) mitral valve area in patients without tricuspid regurgitation was 1.83±0.7 cm2. Mean left atrial (L.A) size was 45.23±1.5 mm2 in patients with tricuspid regurgitation, while it was 44.13±6.14 mm2 in patients without tricuspid regurgitation. Mean RSVP was 57.5mmHg in patients with tricuspid regurgitation while RSVP could not be calculated in patients without tricuspid regurgitation. It was concluded that tricuspid regurgitation was strongly associated with severe mitral stenosis as almost all patients with severe mitral stenosis had tricuspid regurgitation and none of the patients with mild mitral stenosis had tricuspid regurgitation.

  20. The mechanism of endocardial lead-induced tricuspid regurgitation.

    PubMed

    Khoshbin, Espeed; Abdelbar, Abdelrahman; Allen, Stuart; Hasan, Ragheb

    2013-04-09

    Using this case report we attempt to define the mechanism of endocardial lead-induced tricuspid regurgitation (TR) in particular the direct effect of endocardial pacing leads on the competence of the tricuspid valve. We recommend a high index of suspicion and an early diagnostic strategy in order to reduce long-term morbidity which is associated with this condition and the need for a potentially avoidable surgery.

  1. What Is Heart Valve Surgery?

    MedlinePlus

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  2. Can tricuspid annuloplasty of the donor heart reduce valve insufficiency following cardiac transplantation with bicaval anastomosis?

    PubMed

    Fiorelli, Alfredo I; Oliveira, José L; Santos, Ronaldo H B; Coelho, Guilherme B; Oliveira, Adriana S; Lourenço-Filho, Domingos D; Lapenna, Gisele; Dias, Ricardo R; Bacal, Fernando; Bocchi, Edimar A; Stolf, Noedir A G

    2010-06-01

    The aim of this study was to evaluate the degree of tricuspid valve insufficiency after orthotopic cardiac transplantation with bicaval anastomosis and prophylactic donor heart annuloplasty. At present, our cardiac transplantation experience includes 478 cases. After January 2002, we included 30 consecutive patients in this study who had undergone orthotopic cardiac transplantation and survived >6 months. The patients were divided into 2 groups: group I, 15 patients who underwent transplantation with prophylactic tricuspid annuloplasty on the donor heart with the De Vega technique; and group II, 15 patients who underwent transplantation without this procedure. Their preoperative clinical characteristics were the same. During the late postoperative follow-up, the degree of tricuspid insufficiency was evaluated by transthoracic Doppler echocardiography and assessed according to the Simpson scale: 0, absent; 1, mild; 2, moderate; and 3, severe. Hemodynamic parameters were evaluated invasively by means of a Swan-Ganz catheter during routine endomyocardial biopsies. The mean follow-up time was 26.9 +/- 5.4 months (range, 12-36 months). In group I, 1 patient (6.6%) died from infection in the 18th month after the operation; the death was not related to the annuloplasty. In group II, 1 death (6.6%) occurred after 10 months because of rejection (P > .05). After the 24-month follow-up, the mean degree of tricuspid insufficiency was 0.4 +/- 0.5 in group I and 1.7 +/- 0.9 in group II (P < .05). Similarly, the 2 groups were significantly different with respect to the right atrium pressure, which was higher in group II. Prophylactic tricuspid annuloplasty on the donor heart was able to reduce significantly the degree of valvular insufficiency, even in cardiac transplantation with bicaval anastomosis; however, it did not modify significantly the hemodynamic performance of the allograft during the investigation period. It is very important to extend the observation period and

  3. [Tricuspid valve stenosis. A prospective study of 35 cases].

    PubMed

    Diaof, M; Ba, S A; Kane, A; Sarr, M; Diop, I B; Diouf, S M

    2004-01-01

    Authors report the results of prospective and longitudinal study. The aims of this study were to evaluate among 35 patients, prevalence, diagnosis and treatment aspects of tricuspid stenosis (TS), as well as evolution and pronostical factors. The prevalence of TS was about 4.2%. The main clinical signs were: dyspnoea (94.2%), jugular veinus pulses (42.8%), superior cave syndrom (68.8%), diastolic rumble (74.3%). ECG showed sinus rhythm (51.4%), a right atrial hypertrophy (48.5%). Echocardiography showed tricuspid leaflets thickened (82.8%), a right atrial hypertrophy (48.5%), a mean gradient between right atrial and right ventricle: 8.6 +/- 3.14 mmHg (65.7%) and mean tricuspid area about 1.41 +/- 0.83 cm2 (continuous equation); about 1.74 +/- 1.29 cm2 (Hatle formula) and 1.11 0.84 cm2 (simplified Hatle formula). Aetiology was only rheumatic fever. After a follow-up of 8.53 +/- 6.06 months, the mortality rate was 28.5%. Complications were irreducible heart failure (24 cases), liver failure (2 cases) and stroke (3 cases). Factors associated with mortality were: severity of tricuspid stenosis and pulmonary hypertension, importance of dyspnea and heart failure (p < 0.041).

  4. [Assessment of Tricuspid Insufficiency and the Function of Right Ventricle Using Cardiac Magnetic Resonance Imaging Combined with Echocardiography].

    PubMed

    Chen, Hui; Zhao, Yanling; Yu, Jianqun

    2015-08-01

    Right-sided cardiac valvular diseases have traditionally been considered less important than disease of mitral or aortic valve. However, severe tricuspid regurgitation could lead to right ventricle dysfunction and reduce patients' survival rate. In clinic setting, tricuspid valve disease should be paid more attention for patients with secondary tricuspid regurgitation caused by left-sided valvular surgery combined with irreversible annular dilatation increasing the risk of reoperation. In this review, we summarize the epidemiology, anatomy, pathology, diagnosis, ultrasound and cardiac magnetic resonance imaging findings in patients with tricuspid regurgitation.

  5. Criteria for determining the need for surgical treatment of tricuspid regurgitation during mitral valve replacement

    PubMed Central

    2012-01-01

    Background Tricuspid regurgitation (TR) is common in patients with mitral valve disease; however, there are no straightforward, rapidly determinably criteria available for deciding whether TR repair should be performed during mitral valve replacement. The aim of our retrospective study was to identify a simple and fast criterion for determining whether TR repair should be performed in patients undergoing mitral valve replacement. Methods We reviewed the records of patients who underwent mitral valve replacement with or without (control) TR repair (DeVega or Kay procedure) from January 2005 to December 2008. Preoperative and 2-year postoperative echocardiographic measurements included right ventricular and atrial diameter, interventricular septum size, TR severity, ejection fraction, and pulmonary artery pressure. Results A total of 89 patients were included (control, n = 50; DeVega, n = 27; Kay, n = 12). Demographic and clinical characteristics were similar between groups. Cardiac variables were similar between the DeVega and Kay groups. Right atrium and ventricular diameter and ejection fraction were significantly decreased postoperatively both in the control and operation (DeVega + Kay) group (P < 0.05). Pulmonary artery pressure was significantly decreased postoperatively in-operation groups (P < 0.05). Our findings indicate that surgical intervention for TR should be considered during mitral valve replacement if any of the following preoperative criteria are met: right atrial transverse diameter > 57 mm; right ventricular end-diastolic diameter > 55 mm; pulmonary artery pressure > 58 mmHg. Conclusions Our findings suggest echocardiography may be used as a rapid and simple means of determining which patients require TR repair during mitral valve replacement. PMID:22443513

  6. Optimal surgical management of severe tricuspid regurgitation in cardiac transplant patients.

    PubMed

    Filsoufi, Farzan; Salzberg, Sacha P; Anderson, Curtis A; Couper, Gregory S; Cohn, Lawrence H; Adams, David H

    2006-03-01

    Severe tricuspid regurgitation (TR) with signs of right-sided heart failure is rare after orthotopic heart transplantation (OHT). In some instances, this condition will require surgical correction using reconstructive surgery or prosthetic valve replacement. Repair techniques of atrioventricular valves are now well described. However, the results of the different surgical procedures in this setting have not been widely reported and may depend on the type of valvular dysfunction and lesions present. Herein we report our experience in a group of patients requiring surgical correction of symptomatic severe TR after OHT. We reviewed our transplant experience during the period from July 1992 to July 1999 (n = 138 cardiac transplants). Eight patients (5.8%) developed symptomatic severe TR requiring surgical correction after a mean duration of 21 months after OHT. Patients were divided into 2 groups based on the mechanism of regurgitation using Carpentier's functional classification. In Group 1 (n = 4), the mechanism of tricuspid regurgitation was Carpentier's Type I, secondary to annular dilation. In Group 2 (n = 4) the mechanism of TR was leaflet prolapse (Type II), due to chordal rupture after biopsy injury. Initially, tricuspid valve integrity was surgically restored in all 8 patients with either valve repair (n = 6) or replacement (n = 2). In Group 1, 2 patients underwent valve repair using a ring annuloplasty and 2 patients underwent valve replacement with a bioprosthetic valve (n = 1) or pulmonary allograft (n = 1). In Group 2, all patients underwent valve repair using a variety of techniques in combination with tricuspid annuloplasty. During the follow-up period, 3 of the 6 (50%) primary repairs (1 patient in Group 1 and 2 in Group 2) failed and required replacement with a bioprosthesis at 8 days, 14 days and 4 years, respectively. The pulmonary allograft failed secondary to valvular stenosis and was replaced with a bioprosthesis after 10 months. Overall, no

  7. 3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation.

    PubMed

    Mediratta, Anuj; Addetia, Karima; Yamat, Megan; Moss, Joshua D; Nayak, Hemal M; Burke, Martin C; Weinert, Lynn; Maffessanti, Francesco; Jeevanandam, Valluvan; Mor-Avi, Victor; Lang, Roberto M

    2014-04-01

    This study sought to: 1) determine the feasibility of using 3-dimensional transthoracic echocardiography (3D TTE) in patients with implantable cardiac resynchronization devices, pacemakers, and defibrillators to visualize the device leads in the right heart and their position relative to the tricuspid valve leaflets; 2) determine the prevalence of different lead positions; and 3) study the relationship between lead location and tricuspid regurgitation (TR) severity. Pacemaker, defibrillator, and cardiac resynchronization device implantation is currently guided by fluoroscopy, not allowing targeted lead positioning relative to the tricuspid valve leaflets. These leads have been reported to cause TR of variable degrees, but echocardiography is not routinely used to elucidate the mechanisms of lead interference with tricuspid valve leaflets in individual patients. 3D TTE full-volume images of the right ventricle and/or zoomed images of the tricuspid valve were obtained in 121 patients with implanted devices. Images were viewed offline to determine the position of the device-lead relative to the tricuspid valve leaflets. Severity of TR was estimated on the basis of vena contracta measurements. 3D TTE clearly depicted lead position in 90% of patients. The right ventricular lead was impinging on either the posterior (20%) or septal (23%) leaflet or was not interfering with leaflet motion (53%) when positioned near the posteroseptal commissure or in the central portion of the tricuspid valve orifice. In the remaining patients, leads were impinging on the anterior leaflet (4%) or positioned in either the anteroposterior or anteroseptal commissure (3%). Leads interfering with normal leaflet mobility were associated with more TR than nonimpinging leads (vena contracta: median 0.62 cm [1st and 3rd quartiles: 0.51, 0.84 cm] vs. 0.27 cm [1st and 3rd quartiles: 0.00, 0.48 cm]; p < 0.001). 3D TTE showed a clear association between device lead position and TR. To minimize TR

  8. Single-site ventricular pacing via the coronary sinus in patients with tricuspid valve disease.

    PubMed

    Noheria, Amit; van Zyl, Martin; Scott, Luis R; Srivathsan, Komandoor; Madhavan, Malini; Asirvatham, Samuel J; McLeod, Christopher J

    2018-04-01

    To evaluate coronary sinus single-site (CSSS) left ventricular pacing in adult patients with normal left ventricular ejection fraction (LVEF) when traditional right ventricular lead implantation is not feasible or is contraindicated. We performed a retrospective analysis of 23 patients with tricuspid valve surgery/disease who received a CSSS ventricular pacing lead to avoid crossing the tricuspid valve. Two matched control populations were obtained from patients receiving (i) conventional right ventricular single-site (RVSS) leads and (ii) coronary sinus leads for cardiac resynchronization therapy (CSCRT). Main outcomes of interest were lead stability, electrical lead parameters and change in LVEF during long-term follow-up. Successful CSSS pacing was accomplished in all 23 patients without any procedural complications. During the 5.3 ± 2.8-year follow-up 22/23 (95.7%) leads were functional with stable pacing and sensing parameters, and 1/23 (4.3%) was extracted for unrelated reasons. Compared to CSSS leads, the lead revision/abandonment was similar with RVSS leads (Hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.03, 22.0), but was higher with CSCRT leads (HR 7.41, 95% CI 1.30, 139.0). There was no difference in change in LVEF between CSSS and RVSS groups (-2.4 ± 11.0 vs. 1.5 ± 12.8, P = 0.76), but LVEF improved in CSCRT group (11.2 ± 16.5%, P = 0.002). Fluoroscopy times were longer during implantation of CSSS compared to RVSS leads (25.6 ± 24.6 min vs. 12.3 ± 18.6 min, P = 0.049). In patients with normal LVEF, single-site ventricular pacing via the coronary sinus is a feasible, safe and reliable alternative to right ventricular pacing.

  9. The mechanism of endocardial lead-induced tricuspid regurgitation

    PubMed Central

    Khoshbin, Espeed; Abdelbar, Abdelrahman; Allen, Stuart; Hasan, Ragheb

    2013-01-01

    Using this case report we attempt to define the mechanism of endocardial lead-induced tricuspid regurgitation (TR) in particular the direct effect of endocardial pacing leads on the competence of the tricuspid valve. We recommend a high index of suspicion and an early diagnostic strategy in order to reduce long-term morbidity which is associated with this condition and the need for a potentially avoidable surgery. PMID:23576646

  10. Monophasic Synovial Sarcoma Presenting as Mitral Valve Obstruction

    PubMed Central

    Chokesuwattanaskul, Warangkana; Terrell, Jason; Jenkins, Leigh Ann

    2010-01-01

    We report the case of a 26-year-old man who experienced progressive left-sided chest pain and 2 episodes of near-syncope. Studies revealed a 15-cm mass in the upper left lung, a 10-cm mass in the medial base of the left lung, and a 5-cm left atrial mass that involved the left lung, infiltrated the left pulmonary vein, and prolapsed into the mitral valve, causing intermittent obstruction. The patient underwent surgical excision of the left atrial tumor. Pathologic evaluation confirmed the diagnosis of monophasic synovial sarcoma. To our knowledge, this is only the 3rd report of left atrial invasion and resultant mitral valve obstruction from a synovial sarcoma that infiltrated the pulmonary vein. We believe that this is the 1st documented case of a metastatic left atrial synovial sarcoma in monophasic form. PMID:20844626

  11. Iatrogenic left ventricular-right atrial communication after tricuspid annuloplasty; a case report.

    PubMed

    Tayama, Eiki; Tomita, Yukihiro; Imasaka, Ken-ichi; Kono, Takanori

    2014-06-18

    A 75-year-old man (Asian, Japanese) was readmitted for examination of a heart murmur and haemolytic anemia 3 months after mitral valve and tricuspid annuloplasties and coronary artery bypass. A new systolic murmur was heard, and echocardiography showed a high-velocity jet originating from the left ventricular outflow tract and extending to the right atrium, a small defect between the left ventricle and the right atrium. No periprosthetic leaks were found in the mitral position. We judged that surgical repair of the defect was essential to treat mechanical haemolysis. At operation, we found a communication (3 mm in diameter) just beneath the detached prosthetic ring at the anteroseptal commissure of the tricuspid valve. After partially removing the tricuspid ring from the anteroseptal commissure area, the defect was closed using a single mattress suture with pledget. In this case, the tricuspid annuloplasty stitch in the atrioventricular region was probably placed on the membranous septum rather than on the tricuspid annulus. A tear then occurred in the atrioventricular membranous septum, leading to left ventricular-right atrial communication.

  12. Tricuspid annular plane systolic excursion in dogs with myxomatous mitral valve disease with and without pulmonary hypertension.

    PubMed

    Poser, H; Berlanda, M; Monacolli, M; Contiero, B; Coltro, A; Guglielmini, C

    2017-06-01

    To evaluate tricuspid annular plane systolic excursion (TAPSE) in dogs with myxomatous mitral valve disease (MMVD) with or without pulmonary hypertension (PH) and to study the correlations with clinical and echocardiographic parameters. The study population included 99 dogs with MMVD and tricuspid regurgitation. This is a prospective clinical study. All dogs received a transthoracic echocardiographic evaluation, including 2D, M-mode, echo-Doppler, and tissue Doppler measurements. The TAPSE was measured from the left apical four-chamber view and normalized for the effect of body weight (nTAPSE). The dogs were grouped according to the severity of MMVD (American College of Veterinary Internal Medicine guidelines) and presence/absence and severity of PH. Significant differences between TAPSE or nTAPSE and echocardiographic parameters were analyzed among the MMVD and PH severity groups. Correlations between TAPSE or nTAPSE and echocardiographic parameters were calculated. Tricuspid annular plane systolic excursion or nTAPSE were not significantly different among dogs of the MMVD or PH severity groups. Significant correlations were obtained between TAPSE and body weight, left ventricular and atrial dimensions, early diastolic septal and early diastolic and systolic tricuspid annulus velocity (p<0.001); nTAPSE was significantly correlated with normalized end-diastolic left ventricular dimension and fractional shortening (p<0.001). The results show that neither TAPSE nor nTAPSE are reduced in dogs with MMVD with or without PH. It remains unclear if the right ventricle function is not reduced or if a reduced right ventricle function is masked by the contraction of the left ventricle through ventricular interdependence. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Idiopathic annular dilation: a rare cause of isolated severe tricuspid regurgitation.

    PubMed

    Girard, S E; Nishimura, R A; Warnes, C A; Dearani, J A; Puga, F J

    2000-03-01

    The management of patients with severe tricuspid regurgitation (TR) requires the clinician to clarify the mechanism of regurgitation. Primary disorders of the tricuspid valve, either congenital or acquired, may be readily identified by echocardiography. Severe TR most often results from left-sided heart disease and secondary pulmonary hypertension. Cardiomyopathic processes may also cause right ventricular failure and functional TR. We report three patients with severe TR due to idiopathic annular dilation. The tricuspid valves were otherwise normal on surgical inspection, and the pulmonary pressures were not significantly elevated. Each patient was aged over 65 years and had chronic atrial fibrillation with preserved left ventricular systolic function. Surgical treatment was associated with marked clinical improvement. Clinicians should recognize this unusual but treatable cause of right-sided congestive heart failure.

  14. Initial clinical experience with a novel biodegradable ring in patients with functional tricuspid insufficiency: Kalangos Biodegradable Tricuspid Ring.

    PubMed

    Burma, O; Ustunsoy, H; Davutoglu, V; Celkan, M A; Kazaz, H; Pektok, E

    2007-08-01

    Tricuspid annuloplasty procedures have been widely performed in clinics for many years. The Kalangos Biodegradable Tricuspid Ring (Kalangos Biodegradable Tricuspid Ring, Bioring SA, Lonay, Switzerland) is a novel prosthesis for the treatment of tricuspid insufficiency. The aim of this study was to evaluate the clinical and echocardiographic results of this novel prosthesis for functional tricuspid insufficiency. Between October 2005 and May 2006, 15 patients with the diagnosis of moderate or severe functional tricuspid insufficiency were treated by implantation of a Kalangos Biodegradable Tricuspid Ring. All patients were evaluated clinically and by echocardiography preoperatively, and control tests were performed at the end of the 1st and 6th month following surgery. Moderate and severe insufficiency was documented in 11 and 4 patients, respectively, in the preoperative tests. 1 and 6 months after surgery, 4 patients had trace and 1 patient had mild tricuspid insufficiency, while 10 patients had none. At the 1st and 6th month follow-up, systolic pulmonary arterial pressure, right atrial dimension and right ventricular diastolic diameter were found to be significantly lower than the preoperative values ( P < 0.0001). The right atrial diameter and tricuspid valve area had decreased significantly at the end of the 1st month; however, no significant difference was found between the 1st and 6th month tests ( P > 0.05). Three-quarters of the annuloplasty ring had degraded at 6 months. No complications related to the prosthesis or the procedure occurred within this period. Kalangos Biodegradable Ring is a promising prosthesis in patients with functional tricuspid insufficiency, with encouraging initial results.

  15. Anterior urethral valves: an uncommon cause of obstructive uropathy in children.

    PubMed

    Kibar, Yusuf; Coban, Hidayet; Irkilata, H Cem; Erdemir, Fikret; Seckin, Bedrettin; Dayanc, Murat

    2007-10-01

    Anterior urethral valves (AUV) are rare entities generally described in case reports. They are an uncommon cause of lower urinary tract obstruction in children and can be difficult to diagnose. In the present study, we present our experience in four children with AUV along with a literature review. We retrospectively identified four children with AUV presented between 1998 and 2005 at age 4-9 years. Hematuria, urinary tract infection and weak voiding stream were the most common symptoms. Voiding cystourethrography (VCUG) confirmed the diagnosis of AUV. On cystourethroscopy, cusp-like valves in the anterior urethra were seen in all children. Transurethral endoscopic resection of the valves was carried out in three children using a pediatric resectoscope. In one child with a massive anterior urethral diverticulum, open resection of the valve, diverticulectomy and urethroplasty were performed. All patients were cured, none had complications as a result of surgery, and all reported a normal urinary stream at follow-up. Children with poor stream and recurrent infections should be evaluated carefully and anterior urethral valves should be considered in differential diagnosis of obstructive lesions.

  16. Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies.

    PubMed

    Philip, Femi; Faza, Nadine Nadar; Schoenhagen, Paul; Desai, Milind Y; Tuzcu, E Murat; Svensson, Lars G; Kapadia, Samir R

    2015-08-01

    Patients with severe aortic stenosis due to BAV are excluded from transcatheter aortic valve replacement (TAVR) due to concern for asymmetric expansion and valve dysfunction. We sought to characterize the aortic root and annulus in bicuspid aortic valve (BAV) and tricuspid aortic valves (TAV). We identified patients with severe AS who underwent multi-detector computed tomographic (MDCT) imaging prior to surgical aortic valve replacement (SAVR, n = 200) for BAV and TAVR (n = 200) for TAV from 2010 to 2013. The presence of a BAV was confirmed on surgical and pathological review. Annulus measurements of the basal ring (short- and long-axis, area-derived diameter), coronary ostia height, sinus area (SA), sino-tubular junction area (STJ), calcification and eccentricity index (EI, 1-short axis/long axis) were made. Patients with TAV were older (78.8 years vs. 57.8 years, P = 0.04) than those with BAV. The aortic annulus area (5.21 ± 2.1 cm(2) vs. 4.63 ± 2.0 cm(2) , P = 0.0001), sinus of Valsalva diameter (3.7 ± 0.9 cm vs. 3.1 ± 0.1 cm, P = 0.001) and ascending aorta diameter (3.5 ± 0.7 cm vs. 2.97 ± 0.6 cm, P = 0.001) were significantly larger with BAV. Bicuspid aortic annuli were significantly less elliptical (EI, 1.24 ± 0.1 vs. 1.29 ± 0.1, P = 0.006) and more circular (39% vs. 4%, P < 0.001) compared to the TAV annulus. There was more eccentric annular calcification in BAV vs. TAV (68% vs. 32%, P < 0.001). The mean distance from the aortic annulus to the left main coronary ostium was less than the right coronary ostium. Less than 10% of the BAV annuli would not fit a currently available valved stents. Bicuspid aortic valves have a larger annulus size, sinus of Valsalva and ascending aorta dimensions. In addition, the BAV aortic annuli appear circular and most will fit currently available commercial valved stents. © 2015 Wiley Periodicals, Inc.

  17. Tricuspid regurgitation progression and regression in pulmonary arterial hypertension: implications for right ventricular and tricuspid valve apparatus geometry and patients outcome.

    PubMed

    Medvedofsky, Diego; Aronson, Doron; Gomberg-Maitland, Mardi; Thomeas, Vasiliki; Rich, Stuart; Spencer, Kirk; Mor-Avi, Victor; Addetia, Karima; Lang, Roberto M; Shiran, Avinoam

    2017-01-01

    The aim of this study was to determine the mechanism of tricuspid regurgitation (TR) progression in pulmonary arterial hypertension (PAH) and its effect on survival. We studied 88 patients with PAH and functional TR (mean pulmonary artery pressure 49 ± 14 mmHg; 43% idiopathic PAH) who had serial echocardiograms. TR progression (n = 35) was defined as ≤mild TR on Echo 1 and ≥moderate TR on Echo 2. TR regression (n = 17) was defined as ≥moderate TR on Echo 1 and ≤mild TR on Echo 2. Stable TR (n = 36) was defined as ≤mild TR on both echoes. TR progression was associated with an increase in pulmonary artery systolic pressure (PASP, 62 ± 22-92 ± 23 mmHg, P < 0.0001), right ventricular (RV) enlargement, mainly at mid-ventricular level, increased RV sphericity (6.1 ± 1.7-6.9 ± 1.8, P = 0.004), tricuspid annular (TA) dilatation (4.0 ± 0.7-4.6 ± 0.7 cm, P < 0.0001), and increased tricuspid valve (TV) tenting area (2.0 ± 0.7-2.5 ± 1.0 cm 2 , P = 0.0003). TR regression was associated with a reduction in PASP (84 ± 15-55 ± 18 mmHg, P < 0.0001), reverse RV remodelling with a reduction in RV sphericity (6.3 ± 1.4-5.5 ± 1.0, P = 0.02), and a reduction in TA size (4.1 ± 0.7-3.6 ± 0.7 cm, P = 0.02) and TV tenting (2.1 ± 0.7-1.3 ± 0.5 cm 2 , P = 0.0002). TR progression was associated with all-cause mortality (log-rank P = 0.0007). In PAH, TR progression was associated with worsening pulmonary hypertension and adverse RV and TV apparatus remodelling. TR progression is associated with poor outcome in PAH. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  18. Force Required to Cinch the Tricuspid Annulus: An Ex-Vivo Study

    PubMed Central

    Adkins, Amy; Aleman, Jesus; Boies, Lori; Sako, Edward; Bhattacharya, Shamik

    2016-01-01

    Background and aim of the study Tricuspid annuloplasty is the most preferred technique for the treatment of functional tricuspid regurgitation (FTR). However, high incidences of recurrent regurgitation and risky reoperation demands a deeper insight into the technique. The cinching force required to bring a dilated annulus back to the original size is unknown. The study aim was to quantify the cinching force in the tricuspid annulus which can contribute to the long-term durability of tricuspid annuloplasty and percutaneous device design. Methods In ten ovine hearts, a suture was anchored around the free wall of the tricuspid annulus with the free end attached to a force transducer. The force transducer was mounted on a slider system which pulled the suture at regular intervals. Closure of the tricuspid valve was achieved by pressurizing the right ventricle at 30 mmHg through the pulmonary valve. The suture was pulled to cinch the tricuspid annulus. The tricuspid annulus area was measured from images taken at each increment, and the corresponding force was recorded. The hearts were tested for three conditions: (i) non-pressurized (NP); (ii) pressurized (P; normal), and (iii) dilated-pressurized (DP; diseased). Leakage data were also collected for pressurized and dilated pressurized conditions. Annulus dilation was created by injecting phenol into the annulus. Results The maximum annulus dilation obtained was 8.82%, and the maximum cinching force was 0.38 ± 0.09 N. Leakage was increased by 81.73% from the pressurized to dilated condition. Conclusion The minimal force required to cinch a tricuspid annulus with severe FTR (23.98% dilation) can be approximated to 0.25 N. The required cinching force can play a major role in the long-term durability of the tricuspid annuloplasty. PMID:26897846

  19. Prosthetic aortic valve endocarditis complicated with annular abscess, sub-aortic obstruction and valve dehiscence.

    PubMed

    Hassoulas, Joannis; Patrianakos, Alexandros P; Parthenakis, Fragiskos I; Vardas, Panos E

    2009-01-01

    We present a 76-year-old woman with infective endocarditis of a prosthetic aortic valve. The course of her illness started with an ischaemic stroke and she was admitted with prolonged fever and an episode of loss of consciousness. Echocardiography revealed acute aortic regurgitation and dehiscence of the prosthetic valve with excessive "rocking motion", aortic abscesses and left ventricular outflow obstruction caused by a semilunar shelf of tissue probably due to endocarditis vegetations. She underwent an urgent surgical procedure that confirmed the echocardiographic findings. Our case report reinforces the value of early diagnosis in the presence of a high clinical suspicion of prosthetic valve endocarditis. An extended workup, including transoesophageal echocardiography, in such a patient with a mechanical valve is mandatory.

  20. Dynamic cycling in atrial size and flow during obstructive apnoea

    PubMed Central

    Pressman, Gregg S; Cepeda-Valery, Beatriz; Codolosa, Nicolas; Orban, Marek; Samuel, Solomon P; Somers, Virend K

    2016-01-01

    Objective Obstructive sleep apnoea (OSA) is strongly associated with cardiovascular disease. However, acute cardiovascular effects of repetitive airway obstruction are poorly understood. While past research used a sustained Mueller manoeuver to simulate OSA we employed a series of gasping efforts to better simulate true obstructive apnoeas. This report describes acute changes in cardiac anatomy and flow related to sudden changes in intrathoracic pressure. Methods and results 26 healthy, normal weight participants performed 5–6 gasping efforts (target intrathoracic pressure −40 mm Hg) while undergoing Doppler echocardiography. 14 participants had sufficient echocardiographic images to allow comparison of atrial areas during the manoeuver with baseline measurements. Mitral and tricuspid E-wave and A-wave velocities postmanoeuver were compared with baseline in all participants. Average atrial areas changed little during the manoeuver, but variance in both atrial areas was significantly greater than baseline. Further, an inverse relationship was noted with left atrial collapse and right atrial enlargement at onset of inspiratory effort. Significant inverse changes were noted in Doppler flow when comparing the first beat postmanoeuver (pMM1) with baseline. Mitral E-wave velocity increased 9.1 cm/s while tricuspid E-wave velocity decreased 7.0 cm/s; by the eighth beat postmanoeuver (pMM8) values were not different from baseline. Mitral and tricuspid A-wave velocities were not different from baseline at pMM1, but both were significantly higher by pMM8. Conclusions Repetitive obstructive apnoeas produce dynamic, inverse changes in atrial size and Doppler flow across the atrioventricular valves. These observations have important implications for understanding the pathophysiology of OSA. PMID:27127636

  1. Surgical results of reoperative tricuspid surgery: analysis from the Japan Cardiovascular Surgery Database†.

    PubMed

    Umehara, Nobuhiro; Miyata, Hiroaki; Motomura, Noboru; Saito, Satoshi; Yamazaki, Kenji

    2014-07-01

    Tricuspid valve insufficiency (TI) following cardiovascular surgery causes right-side heart failure and hepatic failure, which affect patient prognosis. Moreover, the benefits of reoperation for severe tricuspid insufficiency remain unclear. We investigated the surgical outcomes of reoperation in TI. From the Japan Cardiovascular Surgery Database (JACVSD), we extracted cases who underwent surgery for TI following cardiac surgery between January 2006 and December 2011. We analysed the surgical outcomes, specifically comparing tricuspid valve replacement (TVR) and tricuspid valve plasty (TVP). Of the 167 722 surgical JACVSD registered cases, reoperative TI surgery occurred in 1771 cases, with 193 TVR cases and 1578 TVP cases. The age and sex distribution was 684 males and 1087 females, with an average age of 66.5 ± 10.8 years. The overall hospital mortality was 6.8% and was significantly higher in the TVR group than in the TVP group (14.5 vs 5.8%, respectively; P < 0.001). Incidences of dialysis, prolonged ventilation and heart block were also significantly higher in the TVR group than in the TVP group. Logistic regression analysis revealed that the risk factors of hospital mortality were older age, preoperative renal dysfunction, preoperative New York Heart Association Class 4, left ventricular dysfunction and TVR. Surgical outcomes following reoperative tricuspid surgery were unsatisfactory. Although TVR is a last resort for non-repairable tricuspid lesions, it carries a significant risk of surgical mortality. Improving the patient's preoperative status and opting for TVP over TVR is necessary to improve the results of reoperative tricuspid surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Aortic valve repair leads to a low incidence of valve-related complications.

    PubMed

    Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim

    2010-01-01

    Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  3. An uncommon cause of tricuspid regurgitation: three-dimensional echocardiographic incremental value, surgical and genetic insights.

    PubMed

    Theron, Alexis; Pinard, Amélie; Riberi, Alberto; Zaffran, Stéphane

    2016-07-01

    Congenital tricuspid valve disease is a rare defect that includes regurgitation, stenosis and Ebstein's anomaly. We report a case of severe tricuspid regurgitation associated with functional mitral regurgitation in a 47-year-old man with congestive heart failure. Transthoracic echocardiography (TTE) ruled out any Ebstein's anomaly. Three-dimensional TTE revealed a 'tricuspid hole' into the anterior leaflet that was only attached to the tricuspid annulus next to both anteroseptal and anteroposterior commissures. There was no sign of leaflet tear or perforation. The surgical repair of the tricuspid and mitral valves was performed with an optimal result. No sign of endocarditis or rheumatic disease was observed during the intervention. Sequence analysis of GATA4, HEY2 and ZFPM2 genes was performed, but no causative mutation was identified. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Does Undersizing of Transcatheter Aortic Valve Bioprostheses during Valve-in-Valve Implantation Avoid Coronary Obstruction? An In Vitro Study.

    PubMed

    Stock, Sina; Scharfschwerdt, Michael; Meyer-Saraei, Roza; Richardt, Doreen; Charitos, Efstratios I; Sievers, Hans-Hinrich; Hanke, Thorsten

    2017-04-01

    Background  The transcatheter aortic valve-in-valve implantation (TAViVI) is an evolving treatment strategy for degenerated surgical aortic valve bioprostheses (SAVBs) in patients with high operative risk. Although hemodynamics is excellent, there is some concern regarding coronary obstruction, especially in SAVB with externally mounted leaflet tissue, such as the Trifecta (St. Jude Medical Inc., St. Paul, Minnesota, United States). We investigated coronary flow and hydrodynamics before and after TAViVI in a SAVB with externally mounted leaflet tissue (St. Jude Medical, Trifecta) with an undersized transcatheter aortic valve bioprosthesis (Edwards Sapien XT; Edwards Lifesciences LLC, Irvine, California, United States) in an in vitro study. Materials and Methods  An aortic root model was constructed incorporating geometric dimensions known as risk factors for coronary obstruction. Investigating the validity of this model, we primarily performed recommended TAViVI with the Sapien XT (size 26 mm) in a Trifecta (size 25 mm) in a mock circulation. Thereafter, hydrodynamic performance and coronary flow (left/right coronary diastolic flow [lCF/rCF]) after TAViVI with an undersized Sapien XT (size 23 mm) in a Trifecta (size 25 mm) were investigated at two different coronary ostia heights (COHs, 8 and 10 mm). Results  Validation of the model led to significant coronary obstruction ( p  < 0.001). Undersized TAViVI showed no significant reduction with respect to coronary flow (lCF: COH 8 mm, 0.90-0.87 mL/stroke; COH 10 mm, 0.89-0.82 mL/stroke and rCF: COH 8 mm, 0.64-0.60 mL/stroke; COH 10 mm, 0.62-0.58 mL/stroke). Mean transvalvular gradients (4-5 mm Hg, p  < 0.001) increased significantly after TAViVI. Conclusions  In our in vitro model, undersized TAViVI with the balloon-expandable Sapien XT into a modern generation SAVB (Trifecta) successfully avoided coronary flow obstruction. Georg Thieme Verlag KG Stuttgart · New York.

  5. Acute obstruction by Pannus in patients with aortic medtronic-hall valves: 30 years of experience.

    PubMed

    Ellensen, Vegard Skalstad; Andersen, Knut Sverre; Vitale, Nicola; Davidsen, Einar Skulstad; Segadal, Leidulf; Haaverstad, Rune

    2013-12-01

    Acute dysfunction of mechanical aortic valve prostheses is a life-threatening adverse event. Pannus overgrowth, which is fibroelastic hyperplasia originating from the periannular area, is one cause of dysfunction. The aim of this study was to determine the annual incidence of readmittance resulting from acute obstruction caused by pannus during 30 years of observation in patients with Medtronic-Hall aortic valve prostheses and to analyze the risk factors associated with pannus development. From 1982 to 2004, 1,187 patients in our department underwent aortic valve replacement with Medtronic-Hall mechanical monoleaflet valve prostheses. As of December 31, 2012, 27 of these patients (2.3%) had presented with acute valve dysfunction caused by pannus obstruction. The annual incidence of pannus was 0.7 per 1,000. The median time from the primary operation to prosthetic dysfunction was 11.1 years (range, 1.2 to 26.8 years). Of the 20 patients who underwent reoperation, 2 died. Seven patients died before reoperation. Women had a higher risk for the development of obstructing pannus, and patients with pannus obstruction were younger. Valve size was not an independent risk factor. Women and younger patients are at higher risk for pannus development. When acute dysfunction by pannus is suspected in a mechanical aortic valve, an immediate echocardiogram and an emergency aortic valve replacement should be carried out because of the potential of a fatal outcome. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Structure and function of the tricuspid and bicuspid regurgitant aortic valve: an echocardiographic study.

    PubMed

    Rönnerfalk, Mattias; Tamás, Éva

    2015-07-01

    The emerging new treatment options for aortic valve disease call for more sophisticated diagnostics. We aimed to describe the echocardiographic pathophysiology and characteristics of the purely regurgitant aortic valve in detail. Twenty-nine men, with chronic aortic regurgitation without concomitant heart disease referred for aortic valve intervention, underwent 2D transoesophageal echocardiographic (TEE) examination prior to surgery according to a previously published matrix. Measurements of the aortic valve apparatus in long and short axis view were made in systole and diastole and analysed off-line. The aortic valves were grouped as tricuspid (TAV) or bicuspid (BAV), and classified by regurgitation mechanism. Twenty-four examinations were eligible for analysis of which 13 presented TAV and 11 BAV. The regurgitation mechanism was classified as dilatation of the aorta in 6 cases, as prolapse in 11 cases and as poor cusp tissue quality or quantity in 7 cases. The ventriculo-aortic junction (VAJ) and valve opening were closely related (TAV r = 0.5, BAV r = 0.73) but no correlation was found between the VAJ and the maximal sinus diameter (maxSiD) or the sinotubular junction (STJ). However, the STJ and maxSiD were significantly related (TAV vs BAV: systole r = 0.9, r = 0.8; diastole r = 0.9, r = 0.7), forming an entity. The conjoined BAV cusps were shorter than the anterior cusps when closed (P = 0.002); the inter-commissural distances of the cusps in the BAV group were significantly different (P = 0.001 resp. 0.03) in both systole and diastole. The VAJ was independent of other aortic dimensions and should thereby be considered as a separate entity with influence on valve opening. The detailed 2D TEE measurements of this study add further important information to our knowledge about the function and echocardiographic anatomy of the pathological aortic valve and root either as a stand-alone examination or as a benchmark and complement to 3D echocardiography. This may

  7. From tricuspid to double orifice Morphology: Percutaneous tricuspid regurgitation repair with the MitraClip device in congenitally corrected-transposition of great arteries.

    PubMed

    Picard, Fabien; Tadros, Victor-Xavier; Asgar, Anita W

    2017-09-01

    Edge to edge transcatheter mitral valve repair with MitraClip (Abbott Vascular, Menlo Park, CA) is increasing for high-risk surgical patients with significant mitral regurgitation. Patients with congenitally corrected transposition of the great arteries (CCTGA) presenting with tricuspid valve regurgitation of a systemic right ventricle may represent particularly challenging candidates for MitraClip given their anatomy. We report the case of a 67-year-old gentleman with CCTGA and severe tricuspid regurgitation who was referred for MitraClip implantation after heart team consensus. Successful implantation of one clip was performed, achieving a significant reduction of the regurgitation. Similarly, favorable findings were confirmed at 6 months, 1 and 2 years follow-up and the patient had no recurrent heart failure admissions after 2-year follow-up. We describe the technical considerations and the importance of 3D-transoesophageal echocardiography for performing the MitraClip of a trileaflet systemic atrioventricular valve. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. Asymptomatic Interrupted Aortic Arch, Severe Tricuspid Regurgitation, and Bicuspid Aortic Valve in a 76-Year-Old Woman.

    PubMed

    Tajdini, Masih; Sardari, Akram; Forouzannia, Seyed Khalil; Baradaran, Abdolvahab; Hosseini, Seyed Mohammad Reza; Kassaian, Seyed Ebrahim

    2016-10-01

    Interrupted aortic arch is a rare congenital abnormality with a high infancy mortality rate. The principal finding is loss of luminal continuity between the ascending and descending portions of the aorta. Because of the high mortality rate in infancy, interrupted aortic arch is very rare among adults. In this report, we describe the case of a 76-year-old woman with asymptomatic interrupted aortic arch, severe tricuspid regurgitation, and bicuspid aortic valve. To our knowledge, she is the oldest patient ever reported with this possibly unique combination of pathologic conditions. In addition to reporting her case, we review the relevant medical literature.

  9. Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis.

    PubMed

    Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh

    2015-09-21

    Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. 2015 BMJ Publishing Group Ltd.

  10. Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis

    PubMed Central

    Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh

    2015-01-01

    Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. PMID:26392458

  11. Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation.

    PubMed

    Nazmul, Mohammed N; Cha, Yong-Mei; Lin, Grace; Asirvatham, Samuel J; Powell, Brian D

    2013-03-01

    Pacemaker and implantable cardioverter-defibrillator (ICD) leads can cause tricuspid valve regurgitation (TR). Few data are available on the best management of significant TR that develops after pacemaker or ICD implantation and regarding any benefits of right ventricular (RV) lead extraction. We sought to determine the impact of RV lead removal on lead-induced TR. We reviewed all patients between 1 January 2000 and 31 December 2010 at the tertiary care hospital who had a preoperative indication of TR and underwent percutaneous extraction of an RV lead with the intent of trying to correct moderate or severe TR. Pre- and post-procedure echoes and clinical data were retrospectively reviewed. In the four patients identified, the RV lead was removed and placed in the coronary sinus to try to improve moderate or severe TR due to lead impingement. There was no significant improvement in the degree of TR except one patient where TR improved slightly from moderate to mild-moderate. All patients had a dilated tricuspid valve annulus by the time of lead extraction. Tricuspid annulus dilatation appeared to account for the persistent TR after RV lead removal. A greater degree of tricuspid valve annulus dilatation may be a marker and mechanism for irreversible lead-induced TR. Further studies are needed to determine whether surgical tricuspid valve repair or replacement combined with RV lead extraction would result in better outcomes than a percutaneous lead extraction approach.

  12. Prevalence and Prediction of Obstructive Coronary Artery Disease in Patients Undergoing Primary Heart Valve Surgery.

    PubMed

    Cazelli, José Guilherme; Camargo, Gabriel Cordeiro; Kruczan, Dany David; Weksler, Clara; Felipe, Alexandre Rouge; Gottlieb, Ilan

    2017-10-01

    The prevalence of coronary artery disease (CAD) in valvular patients is similar to that of the general population, with the usual association with traditional risk factors. Nevertheless, the search for obstructive CAD is more aggressive in the preoperative period of patients with valvular heart disease, resulting in the indication of invasive coronary angiography (ICA) to almost all adult patients, because it is believed that coronary artery bypass surgery should be associated with valve replacement. To evaluate the prevalence of obstructive CAD and factors associated with it in adult candidates for primary heart valve surgery between 2001 and 2014 at the National Institute of Cardiology (INC) and, thus, derive and validate a predictive obstructive CAD score. Cross-sectional study evaluating 2898 patients with indication for heart surgery of any etiology. Of those, 712 patients, who had valvular heart disease and underwent ICA in the 12 months prior to surgery, were included. The P value < 0.05 was adopted as statistical significance. The prevalence of obstructive CAD was 20%. A predictive model of obstructive CAD was created from multivariate logistic regression, using the variables age, chest pain, family history of CAD, systemic arterial hypertension, diabetes mellitus, dyslipidemia, smoking, and male gender. The model showed excellent correlation and calibration (R² = 0.98), as well as excellent accuracy (ROC of 0.848; 95%CI: 0.817-0.879) and validation (ROC of 0.877; 95%CI: 0.830 - 0.923) in different valve populations. Obstructive CAD can be estimated from clinical data of adult candidates for valve repair surgery, using a simple, accurate and validated score, easy to apply in clinical practice, which may contribute to changes in the preoperative strategy of acquired heart valve surgery in patients with a lower probability of obstructive disease.

  13. Prospective study of tricuspid valve regurgitation associated with permanent leads in patients undergoing cardiac rhythm device implantation: Background, rationale, and design

    PubMed Central

    Dokainish, Hisham; Elbarasi, Esam; Masiero, Simona; Van de Heyning, Caroline; Brambatti, Michela; Ghazal, Sami; AL-Maashani, Said; Capucci, Alessandro; Buikema, Lisanne; Leong, Darryl; Shivalkar, Bharati; Saenen, Johan; Miljoen, Hielko; Morillo, Carlos; Divarakarmenon, Syam; Amit, Guy; Ribas, Sebastian; Brautigam, Aaron; Baiocco, Erika; Maolo, Alessandro; Romandini, Andrea; Maffei, Simone; Connolly, Stuart; Healey, Jeff

    2015-01-01

    Given the increasing numbers of cardiac device implantations worldwide, it is important to determine whether permanent endocardial leads across the tricuspid valve can promote tricuspid regurgitation (TR). Virtually all current data is retrospective, and indicates a signal of TR being increased after permanent lead implantation. However, the precise incidence of moderate or greater TR post-procedure, the exact mechanisms (mechanical, traumatic, functional), and the hemodynamic burden and clinical effects of this putative increase in TR, remain uncertain. We have therefore designed a multicenter, international, prospective study of 300 consecutive patients (recruitment completed, baseline data presented) who will undergo echocardiography and clinical assessment prior to, and at 1-year post device insertion. This prospective study will help determine whether cardiac device-associated TR is real, what are its potential mechanisms, and whether it has an important clinical impact on cardiac device patients. PMID:26779517

  14. Coronary ostia obstruction after replacement of aortic valve prostesis

    PubMed Central

    2011-01-01

    Aortic valve replacement (AVR) is the gold standard for the treatment of severe symptomatic aortic stenosis. Complications directly related to surgical procedure are relatively infrequent. Coronary ostial stenosis is, generally, referred as late complication. Anecdotal reports concern coronary ostial stenosis as acute complication. A unique fatal case of intraoperative, bilateral coronary ostial obstruction by prosthetic valve leading to an extensive myocardial infarction is reported. Surgeons must have a high level of vigilance regarding the occurrence of acute myocardial ischemia and sudden death soon after AVR. PMID:21810231

  15. Bicuspid aortic valves: diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT.

    PubMed

    Murphy, David J; McEvoy, Sinead H; Iyengar, Sri; Feuchtner, Gudrun; Cury, Ricardo C; Roobottom, Carl; Baumueller, Stephan; Alkadhi, Hatem; Dodd, Jonathan D

    2014-08-01

    To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P=0.001). Kappa analysis=0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥ 3.8 cm(2), 3.2 cm and 1.6mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P<0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54-1.0), 100%, 100% and 70% respectively. The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT features. Copyright © 2014 Elsevier Ireland Ltd. All rights

  16. Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.

    PubMed

    Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek

    2003-05-01

    Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured

  17. Surgical management of tricuspid stenosis

    PubMed Central

    Cevasco, Marisa

    2017-01-01

    Tricuspid valve stenosis (TS) is rare, affecting less than 1% of patients in developed nations and approximately 3% of patients worldwide. Detection requires careful evaluation, as it is almost always associated with left-sided valve lesions that may obscure its significance. Primary TS is most frequently caused by rheumatic valvulitis. Other causes include carcinoid, radiation therapy, infective endocarditis, trauma from endomyocardial biopsy or pacemaker placement, or congenital abnormalities. Surgical management of TS is not commonly addressed in standard cardiac texts but is an important topic for the practicing surgeon. This paper will elucidate the anatomy, pathophysiology, and surgical management of TS. PMID:28706872

  18. Pulmonary arterial pressure and right ventricular dilatation independently determine tricuspid valve insufficiency severity in pre-capillary pulmonary hypertension.

    PubMed

    De Meester, Pieter; Van De Bruaene, Alexander; Delcroix, Marion; Belmans, Ann; Herijgers, Paul; Voigt, Jens-Uwe; Budts, Werner

    2012-11-01

    Elevated pulmonary artery systolic pressure (PASP) causes functional tricuspid valve insufficiency (TI). However, the differential contribution of pressure load and right ventricular (RV) dilatation is not well established. The study aim was to evaluate both variables in relation to TI. A cross-sectional study was performed of consecutive transthoracic echocardiographic studies of patients with pre-capillary pulmonary hypertension (PH). Both, demographic data and echocardiographic RV parameters were reviewed. TI was graded semi-quantitatively with color Doppler flow imaging. Trend analyses for TI severity (TI grade 0/4, 1/4, 2/4, 3/4, or 4/4) were performed. A proportional odds logistic regression analysis was carried out to identify independent predictors of TI severity. Eighty-one patients (56 females, 25 males; mean age 60 +/- 15 years) with pre-capillary PH were evaluated. Patients with more severe TI had a significantly lower body mass index, a lower mean systemic blood pressure, a shorter pulmonary acceleration time, a higher tricuspid regurgitant gradient, and a more dilated right ventricle. From the echocardiographic parameters, RV dilatation (p = 0.0143) and the tricuspid regurgitant gradient (p = 0.0026) were independently related to the degree of TI. In patients with pre-capillary PH, PASP and RV dilatation were both related to the increasing severity of TI. When focusing on TI to improve the prognosis of patients with pre-capillary PH, both PASP and RV dimensions should be taken into consideration.

  19. Percutaneous treatment of tricuspid regurgitation: A new therapeutic horizon.

    PubMed

    Vilela, Eduardo M; Ribeiro, José; Almeida, João; Fonseca, Marlene; Dias, Adelaide; Primo, João; Braga, Pedro; Gama, Vasco

    2018-03-01

    Functional tricuspid regurgitation is a prevalent disease, especially among patients with other valve disorders, and is associated with significant morbidity and mortality. Its management is challenging, and many patients deemed at high surgical risk are managed conservatively. Despite optimization of pharmacological treatment, many patients continue to be symptomatic, thus leading to interest in percutaneous interventional techniques. The Mitralign system has recently been used for the treatment of functional tricuspid regurgitation, with favorable clinical and imaging results. We report the first case in Portugal to our knowledge of percutaneous tricuspid regurgitation treatment with the Mitralign system. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Delayed recovery of right ventricular systolic function after repair of long-standing tricuspid regurgitation associated with severe right ventricular failure.

    PubMed

    Kim, Jong Hun; Kim, Kyung Hwa; Choi, Jong Bum; Kuh, Ja Hong

    2016-03-01

    After tricuspid valve surgery for long-standing tricuspid regurgitation associated with right ventricular failure, reverse remodelling of the enlarged right ventricle, including recovery of right ventricular systolic function, is unpredictable. We present the case of a 31-year old man with early reduction of dilated right ventricular dimensions and delayed recovery of impaired right ventricular systolic function after valve repair for traumatic tricuspid regurgitation lasting 16 years. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Improvement of tricuspid regurgitation after transcatheter ASD closure in older patients.

    PubMed

    Chen, L; Shen, J; Shan, X; Wang, F; Kan, T; Tang, X; Zhao, X; Qin, Y

    2017-07-19

    Adult patients with undiagnosed atrial septal defect (ASD) may have right heart cavity enlargement and functional tricuspid valve insufficiency. Moderate or more severe tricuspid regurgitation has been associated with a worse prognosis, and more serious complications are typically seen in older patients. This study aimed to evaluate the improvement in functional tricuspid regurgitation and heart geometry after transcatheter ASD closure in older patients. The data of 111 patients over 60 years of age with moderate or severe tricuspid regurgitation before ASD closure were analyzed. At the 1‑month and 6‑month follow-up after closure, both tricuspid regurgitation jet area and right atrial volume decreased significantly. Right ventricular volume decreased 1 month after closure, showing a further decrease at the end of the 6‑month follow-up. However, 24 patients (21.6%) still had persistent severe tricuspid regurgitation after the procedure. Multivariate analysis revealed that patient age at ASD closure and pulmonary artery systolic pressure determined by echocardiography before closure were predictors of persistent tricuspid regurgitation after closure. Transcatheter ASD closure in older patients could significantly decrease tricuspid regurgitation and improve right heart geometry.

  2. Flexible band versus rigid ring annuloplasty for functional tricuspid regurgitation

    PubMed Central

    Izutani, Hironori; Nakamura, Teruya; Kawachi, Kanji

    2010-01-01

    We review and compare our experience with tricuspid ring annuloplasty between usage of the Cosgrove-Edwards flexible band and the MC3 rigid ring for repair of functional tricuspid regurgitation to determine the efficacy and mid-term durability of tricuspid annuloplasty. 117 patients with functional tricuspid regurgitation undergoing open heart surgery and tricuspid valve repair from May 2005 to December 2007 were reviewed. The flexible bands were used in thirty five patients before October 2006. Since then, the rigid rings were used in the next consecutive eighty two cases. Echocardiographic evaluation of tricuspid regurgitation was performed preoperatively and postoperatively in follow-up schedule. The degree of tricuspid regurgitation was reduced from 2.80±0.67 to 0.71±1.0 (regurgitation severity grade: 0 to 4) in the patients with flexible bands at discharge. It was from 2.68±0.70 to 0.22±0.60 in the patients with rigid rings. At thirty six months postoperative period, tricuspid regurgitation grades in patients with flexible bands and rigid rings were 0.80±0.95 and 0.36±0.77, respectively. Freedom from recurrent tricuspid regurgitation (grade 2 or 3) in patients with flexible bands and rigid rings were 68.6% and 87.8%, respectively. Recurrent tricuspid regurgitation was significantly lower in the patients with rigid rings. Although both flexible band and rigid ring annuloplasty provide low rate of recurrent tricuspid regurgitation, rigid ring annuloplasty might be more effective than flexible band annuloplasty for decreasing functional tricuspid regurgitation in immediate and mid-term postoperative periods. PMID:21977298

  3. Effects of morphologic left ventricular pressure on right ventricular geometry and tricuspid valve regurgitation in patients with congenitally corrected transposition of the great arteries.

    PubMed

    Kral Kollars, Catharine A; Gelehrter, Sarah; Bove, Edward L; Ensing, Gregory

    2010-03-01

    Congenitally corrected transposition of the great arteries (CCTGA) is associated with tricuspid regurgitation (TR), which has been postulated to arise from the effect of ventricular septal position on the attachments of the tricuspid valve. This study was performed to determine the effect of left ventricular (LV) pressure on right ventricular (RV) and LV geometry and the degree of TR. Serial echocardiograms were reviewed from, 30 patients with CCTGA who underwent pulmonary artery banding to train the morphologic left ventricle (n = 14) or left ventricle-to-pulmonary artery conduit placement and ventricular septal defect closure in conjunction with physiologic repair (n = 16). The degree of TR, the LV/RV pressure ratio, RV and LV sphericity indexes, and tricuspid valve tethering distance and coaptation length were analyzed. After pulmonary artery banding, an increase in LV systolic pressure to > or =2/3 systemic resulted in a decrease in TR from severe to moderate (p = 0.02). The percentage of patients with severe TR decreased from 64% to 18% (p = 0.06). The RV sphericity index decreased (p = 0.05), and the LV sphericity index increased (p = 0.02). After left ventricle-to-pulmonary artery conduit placement, a decrease in LV pressure to < or =1/2 systemic resulted in an increase in TR from none to mild (p = 0.003). In conclusion, these data indicate that LV pressure in patients with CCTGA affects the degree of TR and that septal shift caused by changes in LV and RV pressure is an important mechanism. Copyright 2010. Published by Elsevier Inc.

  4. Association of Tricuspid Regurgitation With Transcatheter Aortic Valve Replacement Outcomes: A Report From The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.

    PubMed

    McCarthy, Fenton H; Vemulapalli, Sreekanth; Li, Zhuokai; Thourani, Vinod; Matsouaka, Roland A; Desai, Nimesh D; Kirtane, Ajay; Anwaruddin, Saif; Williams, Matthew L; Giri, Jay; Vallabhajosyula, Prashanth; Li, Robert H; Herrmann, Howard C; Bavaria, Joseph E; Szeto, Wilson Y

    2018-04-01

    The purpose of this study is to evaluate the association of tricuspid regurgitation (TR) severity with outcomes after transcatheter aortic valve replacement (TAVR). We analyzed data from 34,576 patients who underwent TAVR at 365 US hospitals from November 2011 through March 2015 submitted to The Society of Thoracic Surgeon/American College of Cardiology Transcatheter Valve Therapy Registry. We examined unadjusted mortality and heart failure readmission stratified by degree of preoperative TR and used multivariable models for 1-year mortality and heart failure readmission. Tricuspid regurgitation was present in 80% (n = 27,804) of TAVR patients, with mild TR in 56% (n = 19,393), moderate TR in 19% (n = 6687), and severe TR in 5% (n = 1,724). Increasing TR severity was associated with a number of comorbidities and The Society of Thoracic Surgeons predicted risk of mortality increased (p < 0.001): no TR (7.3 ± 5.4); mild TR (8.0 ± 5.7); moderate TR (9.6 ± 6.8); and severe TR (10.7 ± 7.4). In unadjusted analysis, moderate and severe TR were associated with increased use of cardiopulmonary bypass, longer intensive care unit and hospital stays, new dialysis, inhospital major adverse cardiac event, inhospital mortality, observed-to-expected inhospital mortality ratio, long-term heart failure readmission, and mortality (p < 0.001). Adjusted mortality at 1 year was significantly worse for patients with severe TR when left ventricular ejection fraction greater than 30% (hazard ratio 1.29, 95% confidence interval: 1.11 to 1.50) as was heart failure readmission (hazard ratio 1.27, 95% confidence interval: 1.04 to 1.54). Tricuspid regurgitation was common among patients undergoing TAVR. Increasing TR severity was associated with higher risk patients and increased mortality and readmission-particularly for patients with severe TR and left ventricular ejection fraction greater than 30%. The effectiveness of TAVR alone in patients with aortic stenosis and concomitant

  5. Transcatheter treatment of severe tricuspid regurgitation with the MitraClip system.

    PubMed

    Hammerstingl, Christoph; Schueler, Robert; Malasa, Margarita; Werner, Nikos; Nickenig, Georg

    2016-03-07

    The aim of this study was to show technical principles and feasibility of transcatheter tricuspid valve repair by use of the MitraClip system. Three consecutive patients were treated successfully for severe symptomatic Tricuspid regurgitation. Three-dimensional transoesophageal echocardiography confirmed reduction of measured effective regurgitant orifice in all patients [effective regurgitant orifice area-baseline/post-procedure (cm(2)): 0.7/0.3; 1.5/0.8; 0.4/0.1], which was accompanied by an increase in left ventricular stroke volumes [baseline/post-procedure (mL): 42.8/45.4; 38/45; 35.2/45], decrease of measured levels of N terminal pro brain natriuretic peptide (pg/mL: baseline/post-procedure: 548/440; 2526/1702; 1754/623), and significant relief of clinical symptoms for chronic right heart failure in all patients. Transcatheter tricuspid valve repair by use of interventional edge-to-edge repair with the MitraClip system was feasible, and safe in three consecutive patients. Reduction of tricuspid insufficiency associates with relief of clinical symptoms for right heart failure. This strategy seems a promising treatment option for patients at prohibitive surgical risk. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  6. The clover technique for the treatment of complex tricuspid valve insufficiency: midterm clinical and echocardiographic results in 66 patients.

    PubMed

    Lapenna, Elisabetta; De Bonis, Michele; Verzini, Alessandro; La Canna, Giovanni; Ferrara, David; Calabrese, Maria Chiara; Taramasso, Maurizio; Alfieri, Ottavio

    2010-06-01

    This study assesses the results of the 'clover technique' (suturing together the middle point of the free edges of the tricuspid leaflets) for the treatment of tricuspid regurgitation (TR) due to severe prolapse or tethering. From 2001, 66 patients with severe TR due to prolapsing or tethered leaflets underwent 'clover repair'. Annuloplasty was associated in 64 patients (97%). The aetiology of TR was degenerative in 52 cases (79%), post-traumatic in eight (12%) and secondary to dilated cardiomyopathy (DCM) in six (9%). The main mechanism of TR was prolapse/flail of one leaflet in 15 patients (23%), of two leaflets in 31 (47%) and of all three leaflets in 14 (21%). The remaining six patients (9%) presented with severe leaflets' tethering. Four deaths (6%) occurred during hospitalisation and one patient died 3.6 years after surgery. Survival was 91 + or - 4.1% at 5 years. Follow-up of the 62 hospital survivors was 100% complete (mean length 3.5 + or - 1.6 years, range 13 months-7.1 years). At the last echocardiogram, no or mild TR was detected in 55 (88.7%) patients, moderate (2+/4+) in six (9.6%) and severe (4+/4+) in one patient (1.6%). Mean tricuspid valve area and gradient were 4.3 + or - 0.6 cm(2) and 2.8 + or -1.4 mmHg. In six patients, stress echocardiography was performed and no signs of tricuspid stenosis were detected. At the multivariable analysis, the degree of TR at hospital discharge was identified as the only predictor of TR > or = 2+ at follow-up. Midterm clinical and echocardiographic results confirm the role of the 'clover technique' in the surgical treatment of TR due to lesions, which are unlikely to be effectively treatable by annuloplasty alone. Copyright 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  7. Severe tricuspid regurgitation and isolated right heart failure due to thyrotoxicosis

    PubMed Central

    Bonou, Maria; Lampropoulos, Konstantinos M.; Andriopoulou, Maria; Kotsas, Dimitrios; Lakoumentas, John; Barbetseas, John

    2012-01-01

    We describe the case of a patient presented with isolated right heart failure with atrial fibrillation and severe tricuspid regurgitation due to hyperthyroidism. Treatment of the thyroid disease resulted in the disappearance of signs of right heart failure and resolution of the valve incompetence and normalization of the heart rhythm. Although thyrotoxicosis may be associated with congestive heart failure, isolated right heart failure with marked tricuspid regurgitation is rarely seen. PMID:23253416

  8. A Case of Traumatic Tricuspid Regurgitation Caused by Multiple Papillary Muscle Rupture

    PubMed Central

    Jin, Han-Young; Seo, Jeong-Sook; Yang, Tae-Hyun; Kim, Dae-Kyeong; Kim, Dong-Kie; Kim, Ung; Seol, Sang-Hoon; Kim, Doo-Il; Kim, Dong-Soo

    2011-01-01

    Traumatic tricuspid regurgitation is a rare complication of blunt chest trauma. With the increase in the number of automobile accidents, traumatic tricuspid regurgitation has become an important problem after blunt chest trauma. It has been reported more frequently because of better diagnostic procedures and a better understanding of the pathology. The early diagnosis of traumatic tricuspid regurgitation is important because traumatic tricuspid injury could be effectively corrected with reparative techniques, early operation is considered to relieve symptoms and to prevent right ventricular dysfunction. Echocardiography can reveal the cause and severity of regurgitation. We experienced a case of tricuspid regurgitation after blunt chest trauma early diagnosis and valve repair were performed. This case reminds the physicians in the emergency department should be aware of this potential complication following non-penetrating chest trauma and echocardiography is useful and should play an early role. PMID:21519493

  9. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome.

    PubMed

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-09-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight into the mechanisms of TVI. It is the intent of this report to propose a systematic method on how to evaluate and display 3DE images of the TV in HLHS which has not been done previously. TV anatomy, function, and the known mechanisms of insufficiency are reviewed. We defined three regions of the TV (anterior, posterior, septal) that can help define valve "leaflets" that incorporates the many variations of TV anatomy. To determine how the surgeon views the TV, a picture of a pathologic specimen of the TV was placed on a computer screen and rotated until it was oriented as it appears during surgery, the "surgeons view." We have proposed a systematic method for evaluating and displaying the TV using 3DE which can provide significant insight into the mechanisms causing TVI in HLHS. This has the potential to improve both the surgical approach to repairing the valve and, ultimately, patient outcomes.

  10. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome

    PubMed Central

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-01-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight into the mechanisms of TVI. It is the intent of this report to propose a systematic method on how to evaluate and display 3DE images of the TV in HLHS which has not been done previously. TV anatomy, function, and the known mechanisms of insufficiency are reviewed. We defined three regions of the TV (anterior, posterior, septal) that can help define valve “leaflets” that incorporates the many variations of TV anatomy. To determine how the surgeon views the TV, a picture of a pathologic specimen of the TV was placed on a computer screen and rotated until it was oriented as it appears during surgery, the “surgeons view.” We have proposed a systematic method for evaluating and displaying the TV using 3DE which can provide significant insight into the mechanisms causing TVI in HLHS. This has the potential to improve both the surgical approach to repairing the valve and, ultimately, patient outcomes. PMID:25298694

  11. Impact of tricuspid valve surgery at the time of left ventricular assist device insertion on postoperative outcomes.

    PubMed

    Dunlay, Shannon M; Deo, Salil V; Park, Soon J

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial. We searched SCOPUS, Web of Science, Ovid EMBASE, and Ovid MEDLINE (through May 10, 2014) for randomized controlled trials and observational studies comparing postoperative outcomes in patients treated with LVAD with concomitant tricuspid valve surgery (TVS) compared with LVAD alone. Six observational studies including 3,249 patients compared outcomes following LVAD + TVS versus LVAD. Four studies were single-center and most did not adjust for potential confounders. Addition of TVS prolonged cardiopulmonary bypass times by an average of 31 minutes (three studies, 95% CI 20-42). There was no difference in need for right ventricular assist device (six studies, HR 1.42, 95% CI 0.54-3.76), acute renal failure (four studies, HR 1.07, 95% CI 0.55-2.10), or early mortality (six studies, HR 1.28, 95% CI 0.78-2.08) in patients treated with LVAD + TVS versus LVAD alone. TVS prolongs cardiopulmonary bypass times, but available data demonstrate no significant association with early postoperative outcomes. However, differences in baseline risk of patients treated with TVS versus not limit our ability to draw conclusions.

  12. Long-Term Results of Mitral Valve Repair

    PubMed Central

    da Costa, Francisco Diniz Affonso; Colatusso, Daniele de Fátima Fornazari; Martin, Gustavo Luis do Santos; Parra, Kallyne Carolina Silva; Botta, Mariana Cozer; Balbi Filho, Eduardo Mendel; Veloso, Myrian; Miotto, Gabriela; Ferreira, Andreia Dumsch de Aragon; Colatusso, Claudinei

    2018-01-01

    Introduction Current guidelines state that patients with severe mitral regurgitation should be treated in reference centers with a high reparability rate, low mortality rate, and durable results. Objective To analyze our global experience with the treatment of organic mitral regurgitation from various etiologies operated in a single center. Methods We evaluated all surgically treated patients with organic mitral regurgitation from 2004-2017. Patients were evaluated clinically and by echocardiography every year. We determined early and late survival rates, valve related events and freedom from recurrent mitral regurgitation and tricuspid regurgitation. Valve failure was defined as any mitral regurgitation ≥ moderate degree or the need for reoperation for any reason. Results Out of 133 patients with organic mitral regurgitation, 125 (93.9%) were submitted to valve repair. Mean age was 57±15 years and 52 patients were males. The most common etiologies were degenerative disease (73 patients) and rheumatic disease (34 patients). Early mortality was 2.4% and late survival was 84.3% at 10 years, which are similar to the age- and gender-matched general population. Only two patients developed severe mitral regurgitation, and both were reoperated (95.6% at 10 years). Freedom from mitral valve failure was 84.5% at 10 years, with no difference between degenerative and rheumatic valves. Overall, late ≥ moderate tricuspid regurgitation was present in 34% of the patients, being more common in the rheumatic ones. The use of tricuspid annuloplasty abolished this complication. Conclusion We have demonstrated that mitral regurgitation due to organic mitral valve disease from various etiologies can be surgically treated with a high repair rate, low early mortality and long-term survival that are comparable to the matched general population. Concomitant treatment of atrial fibrillation and tricuspid valve may be important adjuncts to optimize long-term results. PMID:29617498

  13. Incessant atrial tachycardias in a dog with tricuspid dysplasia. Clinical management and electrophysiology.

    PubMed

    de Madron, E; Kadish, A; Spear, J F; Knight, D H

    1987-01-01

    In a dog, tricuspid regurgitation due to congenital tricuspid dysplasia resulted in extreme right heart enlargement and right heart failure. Incessant supraventricular tachycardias were present, requiring the intravenous administration of verapamil to reduce the ventricular rate. Oral therapy using a combination of verapamil and quinidine was partially effective in controlling the ventricular rate during the following week. At that time, electrophysiologic studies were performed. They revealed that a succession of several atrial tachycardias with different cycle lengths, including one episode of atrial flutter, was present. Atrial activity was spanning the majority of the cycle length in all these arrhythmias. Epicardial mapping was performed during the atrial flutter. This enabled the detection of a depolarization wave-front traveling counterclockwise from the dorsolateral right atrium toward the right appendage, following the tricuspid valve annulus. No areas of abnormal conduction were detected. Because programmed electric stimulation maneuvers could not be performed, definitive conclusions about the mechanism of the arrhythmia could not be drawn. The two most likely possibilities were circus movement using part of the dilated tricuspid valve annulus as an anatomic barrier or a leading circle type of re-entry.

  14. Management of Tricuspid Regurgitation in Patients With Hypoplastic Left Heart Syndrome.

    PubMed

    Pigula, Frank A; Mettler, Bret

    2017-01-01

    Tricuspid valve (TV) performance is critical for palliation of hypoplastic left heart syndrome. We will review current TV repair techniques, outcomes, and novel approaches. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Tricuspid leaflet resection in an open beating heart for the creation of a canine tricuspid regurgitation model.

    PubMed

    Xie, Xu-jing; Liao, Sheng-jie; Wu, Yue-heng; Lu, Cong; Zhu, Ping; Fei, Hong-wen; Xiao, Xue-jun; Huang, Huan-lei

    2016-02-01

    Outcomes of tricuspid valve replacement are poor, partly due to right heart remodelling. The research on its underlying mechanisms is hampered by a lack of animal models of tricuspid regurgitation (TR). Our objective was to create a reproducible and clinically compatible TR animal model to study right heart remodelling caused by TR. Fourteen juvenile male Beagle dogs were divided randomly into an intervention group (n = 11) and a sham-operated control group (n = 3). The intervention group underwent thoracotomy and right atrial incision following superior and inferior vena caval occlusion. The anterior leaflet, together with the chordae, of the tricuspid valve was resected in eight dogs ('one leaflet' group), whereas both anterior and posterior leaflets, together with the chordae, were resected in three dogs ('two leaflets' group). The right atrium and chest were then closed. The control group underwent the same procedure, except leaflet resection. One dog from the 'two leaflets' group and one control dog were sacrificed and autopsy was performed at 12 months post-surgery. All dogs survived over the 1-year observation period postoperatively. TR grade IV occurred immediately postoperatively in the 'one leaflet' group, and TR grade IV plus in the 'two leaflets' group. The overall procedure lasted 30-40 min, and the mean time of vena caval occlusion was 87 ± 10 s. Central venous pressure increased from 6 ± 1.2 at baseline to 13 ± 1.7 mmHg (P < 0.01). By 12 months after TR creation, both in the 'one leaflet' group and in the 'two leaflets' group, the right atrial area, tricuspid annular diameter and right ventricular index of myocardial performance increased significantly, right ventricular fractional area change and tricuspid annular plane systolic excursion decreased significantly. Autopsy of the intervention dog revealed oedema, ascites and cirrhosis. Our surgical technique to create a TR animal model was reproducible with high success and survival rates. This

  16. Multimodality imaging to plan and guide transcatheter tricuspid valve interventions.

    PubMed

    Prihadi, Edgard A; Delgado, Victoria; Bax, Jeroen J

    2017-10-01

    Tricuspid regurgitation (TR) is a highly prevalent valvular heart disease. The natural history of untreated significant TR portends an unfavorable outcome, but only a minority of patients is currently referred for surgical treatment. Organic TR (caused by primary abnormality of the leaflets) is relatively infrequent whereas secondary or functional TR (caused by dilatation of the tricuspid annulus, right ventricle [RV] and right atrium) is the predominant mechanism. The success of transcatheter therapies for left valvular heart disease over the last decade, has fueled similar development of novel transcatheter devices for the treatment of TR. Currently being tested in several clinical trials, each of these devices requires specific needs to define the procedural suitability. In addition, an accurate evaluation of the complex tricuspid anatomy, RV geometry and their relationship with the surrounding structures is mandatory. Therefore, accurate pre-procedural assessment using multimodality imaging techniques will undoubtedly play a pivotal role in achieving procedural success and safety. This review article provides a comprehensive overview on the etiology and different mechanisms of TR, and highlights the role of multimodality imaging techniques in the assessment of TR severity, RV dysfunction and fulfilment of device-specific selection criteria.

  17. Severe isolated tricuspid insufficiency due to tricuspid papillary muscle rupture after a fall from a horse: treatment with port access minimally invasive cardiac surgery.

    PubMed

    Öz, Kürsad; Mayeran, Yousef; Van Praet, Frank; Codens, Jose; Vanerman, Hugo

    2014-04-01

    We report on the successful treatment of tricuspid valve insufficiency due to blunt chest injury using port-access minimally invasive cardiac surgery. The optimal surgical treatment of traumatic valvular insufficiency is discussed, including a brief review of the relevant literature.

  18. Left ventricle to aorta valved conduit for relief of diffuse left ventricular outflow tract obstruction.

    PubMed

    Reder, R F; Dimich, I; Steinfeld, L; Litwak, R S

    1977-06-01

    Operative relief of congenital tunnel subaortic stenosis by means of local incision or excision, or both, has generally been unsatisfactory. The use of a valve-bearing conduit between the left ventricular apex and thoracic aorta offers a predictable means of bypassing the left ventricular outflow obstruction. The procedure was used in a 17 year old girl with an excellent hemodynamic result. The history of operative management with diverting plantation of valved conduits in this position have not been defined, but use of these prostheses appears advisable in severe subvalvular, valvular and supravalvular obstructions that are not readily amenable to predictable and safe surgical palliation. The operation may prove useful in selected cases of idiopathic hypertrophic obstructive cardiomyopathy.

  19. Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve

    PubMed Central

    Pasta, Salvatore; Rinaudo, Antonino; Luca, Angelo; Pilato, Michele; Scardulla, Cesare; Gleason, Thomas G.; Vorp, David A.

    2014-01-01

    The aortic dissection (AoD) of an ascending thoracic aortic aneurysm (ATAA) initiates when the hemodynamic loads exerted on the aneurysmal wall overcome the adhesive forces holding the elastic layers together. Parallel coupled, two-way fluid–structure interaction (FSI) analyses were performed on patient-specific ATAAs obtained from patients with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) to evaluate hemodynamic predictors and wall stresses imparting aneurysm enlargement and AoD. Results showed a left-handed circumferential flow with slower-moving helical pattern in the aneurysm's center for BAV ATAAs whereas a slight deviation of the blood flow toward the anterolateral region of the ascending aorta was observed for TAV ATAAs. Blood pressure and wall shear stress were found key hemodynamic predictors of aneurysm dilatation, and their dissimilarities are likely associated to the morphological anatomy of the aortic valve. We also observed discontinues, wall stresses on aneurysmal aorta, which was modeled as a composite with two elastic layers (i.e., inhomogeneity of vessel structural organization). This stress distribution was caused by differences on elastic material properties of aortic layers. Wall stress distribution suggests AoD just above sinotubular junction. Moreover, abnormal flow and lower elastic material properties that are likely intrinsic in BAV individuals render the aneurysm susceptible to the initiation of AoD. PMID:23664314

  20. Successful continuous-flow left ventricular assist device implantation with adjuvant tricuspid valve repair for advanced heart failure.

    PubMed

    Lee, Chih-Hsien; Wei, Jeng

    The prevalence of end-stage heart failure (HF) is on the increase, however, the availability of donor hearts remains limited. Left ventricular assist devices (LVADs) are increasingly being used for treating patients with end-stage HF. LVADs are not only used as a bridge to transplantation but also as a destination therapy. HeartMate II, a new-generation, continuous-flow LVAD (cf-LVAD), is currently an established treatment option for patients with HF. Technological progress and increasing implantation of cf-LVADs have significantly improved survival in patients with end-stage HF. Here we report a case of a patient with end-stage HF who was successfully supported using cf-LVAD implantation with adjuvant tricuspid valve repair in a general district hospital.

  1. Aortic cusp extension valvuloplasty with or without tricuspidization in children and adolescents: long-term results and freedom from aortic valve replacement.

    PubMed

    Polimenakos, Anastasios C; Sathanandam, Shyam; Elzein, Chawki; Barth, Mary J; Higgins, Robert S D; Ilbawi, Michel N

    2010-04-01

    Aortic cusp extension valvuloplasty is increasingly used in the management of children and adolescents with aortic stenosis or regurgitation. The durability of this approach and the freedom from valve replacement are not well defined. A study was undertaken to investigate outcomes. From July 1987 to November 2008, 142 patients aged less than 19 years underwent aortic cusp extension valvuloplasty in the form of pericardial cusp extension and tricuspidization (when needed). Three patients with truncus arteriosus and severe truncal valve insufficiency were excluded. From the available follow-up data of 139 patients, 50 had bicuspid aortic valves, 40 had congenital aortic valve stenosis, 41 had combined congenital aortic valve stenosis/insufficiency, and 8 had other diagnoses. Median follow-up was 14.4 years (0.1-21.4). Long-term mortality and freedom from aortic valve replacement were studied. There were no early, intermediate, or late deaths. Z-values of left ventricular end-diastolic dimension, aortic annulus, aortic sinus diameter, and sinotubular junction diameter before aortic valve replacement were 4.2 +/- 3.11, 2.3 +/- 1.25, 4.4 +/- 1.23, and 1.84 +/- 1.28, respectively. During the follow-up period, 64 patients underwent aortic valve reinterventions. The Ross procedure was performed in 32 of 139 patients (23%) undergoing aortic cusp extension valvuloplasty. Other aortic valve replacements were undertaken after 16 aortic cusp extension valvuloplasties (11.5%). Freedom from a second aortic cusp extension valvuloplasty or aortic valve replacement at 18 years was 82.1% +/- 4.2% and 60.0% +/- 7.2%, respectively. Aortic cusp extension valvuloplasty is a safe and effective surgical option with excellent survival and good long-term outcomes in children and adolescents. The procedure provides acceptable durability and satisfactory freedom from aortic valve replacement. Copyright 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  2. All in the family: matrimonial mitral valve clicks.

    PubMed

    Desser, K B; Bokhari, S I; Benchimol, A; Romney, D

    1981-05-01

    Mitral valve clicks with or without late systolic murmurs were detected in genetically unrelated marital partners of 5 families. The first family represented 2 successive nonconsanguineous marital unions with 3 generations of mitral valve clicks. The second family included 1 natural and 2 adopted children with clinical and echographic evidence of mitral valve prolapse. The third family was comprised of asymptomatic parents, both with nonejection clicks and mitral valve prolapse, whose daughter presented 3 years previously with syncope, palpitations, and combined mitral and tricuspid valve prolapse. The fourth family had 3 members with auscultatory and ultrasonic manifestations of billowing mitral valve, whereas the fourth member had "silent mitral valve prolapse." The fifth family represented a mother with auscultatory and echographic evidence of mitral valve prolapse; her 14-year-old daughter had both mitral and tricuspid valve prolapse, whereas the son had a bicuspid aortic valve. Both children were products of a prior marriage, and her husband has symptomatic mitral valve prolapse. We conclude that matrimonial mitral valve prolapse probably reflects the purported (6--10%) prevalence of this disorder in the general population. The consequences of such marital union on progeny is currently unclear and warrants future investigation.

  3. Dilatation of the initially non-aneurysmal ascending aorta after replacement of a bicuspid versus tricuspid aortic valve.

    PubMed

    Zhang, Jing; Fan, Guangpu; Zhao, Hui; Wang, Xu; Wang, Zhiwei; Zhang, Peide; Wang, Wei

    2016-12-01

    Objective To compare the aortic diameter after isolated aortic valve replacement (AVR) in patients with a bicuspid (BAV) or tricuspid aortic valve (TAV) and an initially normal ascending aorta. Methods Patients with an ascending aortic diameter of < 45 mm who had undergone isolated AVR were studied. Ultrasonic cardiographic measurements of the ascending aortic diameter made pre- and postoperatively and follow-up data concerning adverse aortic events and death were analyzed. Results A total of 613 patients were included in this retrospective study; of these, 211 had a BAV and 402 had a TAV. In both groups, the ascending aorta significantly expanded but was non-aneurysmal during follow-up; however, the difference between the two groups was not significant. Cox regression analysis showed no significant effect associated with the presence of a BAV on adverse aortic events or death. Conclusion Dilatation of the ascending aorta was observed after AVR in both groups, but was not more pronounced in patients with a BAV. Long-term follow-up for ascending aortic aneurysm is necessary after AVR in both patients with a BAV and those with a TAV.

  4. Dilatation of the initially non-aneurysmal ascending aorta after replacement of a bicuspid versus tricuspid aortic valve

    PubMed Central

    Zhang, Jing; Fan, Guangpu; Zhao, Hui; Wang, Xu; Wang, Zhiwei; Zhang, Peide

    2016-01-01

    Objective To compare the aortic diameter after isolated aortic valve replacement (AVR) in patients with a bicuspid (BAV) or tricuspid aortic valve (TAV) and an initially normal ascending aorta. Methods Patients with an ascending aortic diameter of < 45 mm who had undergone isolated AVR were studied. Ultrasonic cardiographic measurements of the ascending aortic diameter made pre- and postoperatively and follow-up data concerning adverse aortic events and death were analyzed. Results A total of 613 patients were included in this retrospective study; of these, 211 had a BAV and 402 had a TAV. In both groups, the ascending aorta significantly expanded but was non-aneurysmal during follow-up; however, the difference between the two groups was not significant. Cox regression analysis showed no significant effect associated with the presence of a BAV on adverse aortic events or death. Conclusion Dilatation of the ascending aorta was observed after AVR in both groups, but was not more pronounced in patients with a BAV. Long-term follow-up for ascending aortic aneurysm is necessary after AVR in both patients with a BAV and those with a TAV. PMID:27484890

  5. Recurrent tricuspid insufficiency: is the surgical repair technique a risk factor?

    PubMed

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair. In our clinic, 93 patients with functional tricuspid insufficiency underwent surgical tricuspid repair from May 2007 through October 2010. The study was retrospective, and all the data pertaining to the patients were retrieved from hospital records. Functional capacity, recurrent tricuspid insufficiency, and risk factors aggravating the insufficiency were analyzed for each patient. In the medium term (25.4 ± 10.3 mo), the rates of grades 3 and 4 tricuspid insufficiency in the De Vega, modified De Vega, and ring annuloplasty groups were 31%, 23.1%, and 6.1%, respectively. Logistic regression analysis revealed that chronic obstructive pulmonary disease, left ventricular dysfunction (ejection fraction, < 0.50), pulmonary artery pressure ≥60 mmHg, and the De Vega annuloplasty technique were risk factors for medium-term recurrent grades 3 and 4 tricuspid insufficiency. Medium-term survival was 90.6% for the De Vega group, 96.3% for the modified De Vega group, and 97.1% for the ring annuloplasty group. Ring annuloplasty provided the best relief from recurrent tricuspid insufficiency when compared with DeVega annuloplasty. Modified De Vega annuloplasty might be a suitable alternative to ring annuloplasty when rings are not available.

  6. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    PubMed

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  7. Mechanical valve replacement in congenital heart disease.

    PubMed

    Fiane, A E; Lindberg, H L; Saatvedt, K; Svennevig, J L

    1996-05-01

    Mechanical valves are the prosthesis of choice in valve replacement in children. However, the problem of somatic growth leading to patient-valve mismatch remains present, and the appropriate anticoagulation regimen remains controversial. We present our experience of valve replacement in a young population over 20 years. Between 1972 and 1992, 48 patients (34 males and 14 females), mean age 11.2 years (range 0.4-27.4 years), underwent mechanical valve replacement at our institution. Aortic valve replacement was performed in 28 patients (58.3%), mitral valve replacement in 13 (27.1%), tricuspid valve replacement in six (12.5%) and pulmonary valve replacement in one patient (2.1%). The prostheses used were: St. Jude Medical (n = 2), Björk-Shiley (n = 14), Medtronic Hall (n = 16), Duromedics (n = 2) and CarboMedics (n = 14). Early mortality was 14.3%, 10.7% for aortic valve replacement and 30.8% for mitral valve replacement. Mean follow up for all patients was 8.3 years (range 0-22 years), with a total of 398 patient-years. Seven patients died during the follow up (17.1%). Survival after 10 years, including operative mortality, was 81% for aortic valve replacement, 33% for mitral valve replacement, 83% for tricuspid valve replacement and 100% for pulmonary valve replacement. All patients were anticoagulated with warfarin. In eight patients (16.7%) an antiplatelet drug (aspirin or dipyridamole) was added. Major events included paravalvular leak in six patients (1.5%/pty), valve thrombosis in five (mitral position in two, tricuspid in three) (1.3%/pty) and endocarditis in one patient (0.3%/pty). Minor thromboembolic events occurred in three patients (0.8%/pty) and minor hemorrhagic events in three (0.8%/pty). No patients developed hemolytic anemia and there was no case of structural failure. In our experience, mechanical prostheses in congenital heart disease were associated with significant morbidity and mortality, however long term survival after aortic valve

  8. Early and mid-term clinical outcome in younger and elderly patients undergoing mitral valve repair with or without tricuspid valve repair.

    PubMed

    Renner, André; Zittermann, Armin; Aboud, Anas; Hakim-Meibodi, Kavous; Börgermann, Jochen; Gummert, Jan F

    2015-01-01

    Data regarding durability and midterm benefits of mitral valve (MV) repair in elderly patients are scarce. To evaluate the feasibility and safety of MV repair in elderly patients, we performed a retrospective data analysis. We compared clinical outcomes in younger patients (<75 years: n = 462) and older patients (≥75 years: n = 100) undergoing MV repair with or without tricuspid valve (TV) repair. The primary end-point was 30-day mortality. The preoperative risk profile (EuroSCORE, NYHA class, percentage pulmonary hypertension, percentage diabetes) was higher in older patients compared with younger patients. Nevertheless, operative complications such as low cardiac output syndrome, stroke, infections, the need of haemofiltration and IABP use did not differ significantly between the two groups. The thirty-day mortality rate was 0% in older patients and 1% in younger patients (P = 0.30). In the subgroup of patients with double valve repair, the 30-day mortality rate in older patients (n = 28) and younger patients (n = 46) was 0 and 4%, respectively (P = 0.27). In older and younger patients, the 6-month mortality rate was 4 and 2%, respectively (P = 0.16), and the 1-year mortality rate was 10 and 3%, respectively (P = 0.001). The propensity score-adjusted odds ratio of 1-year mortality with the group of younger patients as a reference was 2.04 (95% confidence interval: 0.77-5.40; P = 0.15) for older patients. Freedom from 1-year reoperation did not differ significantly between age groups. Data demonstrate excellent postoperative mortality rates in older patients undergoing MV repair with or without TV repair. Consequently, even in older patients with numerous comorbidities, MV repair should be considered a suitable surgical method. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Acquired cyanotic heart disease secondary to traumatic tricuspid regurgitation. Case report with a review of the literature.

    PubMed

    Bardy, G H; Talano, J V; Meyers, S; Lesch, M

    1979-12-01

    A case of traumatic tricuspid insufficiency leading to right atrial enlargement and to a patent foramen ovale with right to left shunting is presented. Six similar cases previously reported are reviewed. The time course of clinical deterioration was related to the type of tricuspid valve damage incurred. Papillary muscle rupture led to surgery within a year, whereas less severe chordal damage allowed a more benign course that lasted from 10 to 25 years from the time of injury to the time of surgery. Surgical repair of the incompetent tricuspid valve and closure of the atrial septal defect led to significant improvement. The diagnostic usefulness of radionuclide imaging and echocardiography is demonstrated in this case. A mechanism of right to left interatrial shunting in the presence of normal pulmonary arterial pressures is proposed; this invokes phasic increases in right atrial pressure from tricuspid insufficiency and streaming of blood from the inferior vena cava into the left atrium across a patent foramen ovale in a manner that resembles conditions in the fetal circulation.

  10. Prevalence, Predictors and Clinical Outcome of Residual Pulmonary Hypertension Following Tricuspid Annuloplasty.

    PubMed

    Chen, Yan; Liu, Ju-Hua; Chan, Daniel; Sit, Ko-Yung; Wong, Chun-Ka; Ho, Kar-Lai; Ho, Lai-Ming; Zhen, Zhe; Lam, Yui-Ming; Lau, Chu-Pak; Au, Wing-Kok; Tse, Hung-Fat; Yiu, Kai-Hang

    2016-07-22

    Tricuspid annuloplasty is increasingly performed during left heart valve surgery, but the long-term clinical outcome postoperatively is not satisfactory. The aim of this study was to determine whether residual pulmonary hypertension (PHT) contributes to the adverse outcome. One-hundred thirty-seven patients (age 61±11 years; men, 30%) who underwent tricuspid annuloplasty during left-side valve surgery were enrolled. The mean pulmonary artery systolic pressure before surgery was 49±13 mm Hg and 32±15 mm Hg following surgery. Patients were divided into 3 groups according to postoperative pulmonary artery systolic pressure: no residual PHT (n=78, 57%), mild residual PHT (n=43, 31%), or significant residual PHT (n=16, 12%). A preoperative larger right ventricular (RV) geometry and tricuspid valve tethering area were associated with mild or significant residual PHT. A total of 24 adverse events (20 heart failures and 4 cardiovascular deaths) occurred during a median follow-up of 25 months. Kaplan-Meier survival curve demonstrated that patients with significant residual PHT had the highest percentage of adverse events followed by those with mild residual PHT. Patients with no residual PHT had a very low risk of adverse events. Multivariable Cox regression analysis revealed that both mild (hazard ratio=4.94; 95% CI =1.34-18.16; P=0.02) and significant residual PHT (hazard ratio=8.67; 95% CI =2.43-30.98; P<0.01) were independent factors associated with adverse events. The present study demonstrated that 43% of patients who underwent tricuspid annuloplasty had residual PHT. The presence of mild or significant residual PHT was associated with adverse events in these patients. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  11. [Method to make the tricuspid extracardiac conduit by heterogeneous pericardium].

    PubMed

    Yamagishi, M; Imai, Y; Koh, Y; Nagatsu, M; Matsuo, K; Kurosawa, H

    1992-07-01

    We described here, how to make tricuspid extracardiac conduit by heterogeneous pericardium for Rastelli procedure. We have developed some ingenious devices which allow to obtain good hemodynamics. One of the devices is large valvular leaflets as long as 130% of the circumference of the conduit. Another device is the commissural suture as figure of eight. We used 121 tricuspid extracardiac conduits between January 1985 and March 1991. There were two reoperations: One from stenosis at the suture with ventricle and the other from infective endocarditis. This hand-made conduit has the advantages of flexibility, fitness with the pulmonary artery, wide range of size and very little regurgitation. These advantages indicate that the tricuspid extracardiac conduit made by heterogeneous pericardium is a valved conduit substitute of choice for Rastelli procedure. The durability of the conduit is to be further evaluated.

  12. Do pulmonary artery catheters cause or increase tricuspid or pulmonic valvular regurgitation?

    PubMed

    Sherman, S V; Wall, M H; Kennedy, D J; Brooker, R F; Butterworth, J

    2001-05-01

    There are few quantitative data on the extent or mechanism of pulmonary artery catheter (PAC)-induced valvular dysfunction. We hypothesized that PACs cause or worsen tricuspid and pulmonic valvular regurgitation, and tested this hypothesis by using transesophageal echocardiography. In 54 anesthetized adult patients, we measured color Doppler jet areas of tricuspid regurgitation (TR) in two planes (midesophageal [ME] 4-chamber and right ventricular inflow-outflow views) and pulmonic insufficiency (PI) in one plane (ME aortic valve long-axis view), both before and after we advanced a PAC into the pulmonary artery. Regurgitant jet areas and hemodynamic measurements were compared by using paired t-test. There were no significant changes in blood pressure or heart rate after passage of the PAC. After PAC placement, the mean PI jet area was not significantly increased. The mean TR jet area increased significantly in the right ventricular inflow-outflow view (+0.37 +/- 0.11 cm(2)) (P = 0.0014), but did not increase at the ME 4-chamber view. Seventeen percent of patients had an increase in TR jet area > or =1 cm(2); 8% of patients had an increase in PI jet area >/=1 cm(2). In patients without pulmonic or tricuspid valvular pathology, placement of a pulmonary artery catheter (PAC) worsened tricuspid regurgitation, which is consistently visualized in the right ventricular inflow-outflow view, and often not seen in the midesophageal 4-chamber view. This is consistent with malcoaptation of the anterior and posterior leaflets. PAC-induced pulmonic insufficiency was rarely detected in the midesophageal aortic valve long-axis view. We conclude that a PAC is very unlikely to be the sole cause of severe tricuspid regurgitation or pulmonic insufficiency.

  13. Surgical treatment of traumatic tricuspid insufficiency: experience in 13 cases.

    PubMed

    Ma, Wei-Guo; Luo, Guo-Hua; Sun, Han-Song; Xu, Jian-Ping; Hu, Sheng-Shou; Zhu, Xiao-Dong

    2010-12-01

    Traumatic tricuspid insufficiency (TTI) is uncommon and surgical experience is limited. We report our surgical experience with TTI in 13 patients. From January 2000 through March 2008, we operated on 13 patients with TTI (10 men 3 women; mean age, 39.8 ± 10.5 years). The intervals from trauma to diagnosis and from trauma to surgery averaged 37.4 and 54.4 months, respectively. At operation, the mechanism of TTI was due to anterior chordal rupture in 8, anterior papillary muscle rupture in 3, rupture of anterior papillary muscle and chordae in 1, and anterior leaflet defect in 1. In 7 patients the annulus was dilated. Valve repair was successful in 13 patients. No early or late deaths occurred. Severe hemolysis occurred in 1 patient after tricuspid and mitral valve repairs. At follow-up extending to 9.5 years, 9 patients were in New York Heart Association functional class I, and 4 were in class II. Transthoracic echocardiography demonstrated no or trivial residual regurgitation in 7 patients, mild regurgitation in 4, and mild-to-moderate regurgitation in 2. A significant decrease of the right ventricular end-diastolic dimension (37.7 ± 9.7 vs 20.7 ± 4.6 mm; p < 0.001) was observed. The mean transvalvular gradient was 2.5 ± 0.8 mm Hg. Eleven patients were in sinus rhythm. Satisfactory early and midterm outcomes can be achieved for TTI by tricuspid valve repair. Early surgical intervention should be emphasized to achieve good functional results and preserve the right ventricular function. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Effect of tricuspid regurgitation and the right heart on survival after transcatheter aortic valve replacement: insights from the Placement of Aortic Transcatheter Valves II inoperable cohort.

    PubMed

    Lindman, Brian R; Maniar, Hersh S; Jaber, Wael A; Lerakis, Stamatios; Mack, Michael J; Suri, Rakesh M; Thourani, Vinod H; Babaliaros, Vasilis; Kereiakes, Dean J; Whisenant, Brian; Miller, D Craig; Tuzcu, E Murat; Svensson, Lars G; Xu, Ke; Doshi, Darshan; Leon, Martin B; Zajarias, Alan

    2015-04-01

    Tricuspid regurgitation (TR) and right ventricular (RV) dysfunction adversely affect outcomes in patients with heart failure or mitral valve disease, but their impact on outcomes in patients with aortic stenosis treated with transcatheter aortic valve replacement has not been well characterized. Among 542 patients with symptomatic aortic stenosis treated in the Placement of Aortic Transcatheter Valves (PARTNER) II trial (inoperable cohort) with a Sapien or Sapien XT valve via a transfemoral approach, baseline TR severity, right atrial and RV size and RV function were evaluated by echocardiography according to established guidelines. One-year mortality was 16.9%, 17.2%, 32.6%, and 61.1% for patients with no/trace (n=167), mild (n=205), moderate (n=117), and severe (n=18) TR, respectively (P<0.001). Increasing severity of RV dysfunction as well as right atrial and RV enlargement were also associated with increased mortality (P<0.001). After multivariable adjustment, severe TR (hazard ratio, 3.20; 95% confidence interval, 1.50-6.82; P=0.003) and moderate TR (hazard ratio, 1.60; 95% confidence interval, 1.02-2.52; P=0.042) remained associated with increased mortality as did right atrial and RV enlargement, but not RV dysfunction. There was an interaction between TR and mitral regurgitation severity (P=0.04); the increased hazard of death associated with moderate/severe TR only occurred in those with no/trace/mild mitral regurgitation. In inoperable patients treated with transcatheter aortic valve replacement, moderate or severe TR and right heart enlargement are independently associated with increased 1-year mortality; however, the association between moderate or severe TR and an increased hazard of death was only found in those with minimal mitral regurgitation at baseline. These findings may improve our assessment of anticipated benefit from transcatheter aortic valve replacement and support the need for future studies on TR and the right heart, including whether

  15. Impact of Implantable Transvenous Device Lead Location on Severity of Tricuspid Regurgitation

    PubMed Central

    Addetia, Karima; Maffessanti, Francesco; Mediratta, Anuj; Yamat, Megan; Weinert, Lynn; Moss, Joshua D.; Nayak, Hemal M.; Burke, Martin C.; Patel, Amit R.; Kruse, Eric; Jeevanandam, Valluvan; Mor-Avi, Victor; Lang, Roberto M.

    2015-01-01

    Background Implantable device leads can cause tricuspid regurgitation (TR) when they interfere with leaflet motion. The aim of this study was to determine whether lead-leaflet interference is associated with TR severity, independent of other causative factors of functional TR. Methods A total of 100 patients who underwent transthoracic two-dimensional and three-dimensional (3D) echocardiography of the tricuspid valve before and after lead placement were studied. Lead position was classified on 3D echocardiography as leaflet-interfering or noninterfering. TR severity was estimated by vena contracta (VC) width. Logistic regression analysis was used to identify factors associated with postdevice TR, including predevice VC width, right ventricular end-diastolic and end-systolic areas, fractional area change, right atrial size, tricuspid annular diameter, TR gradient, device lead age, and presence or absence of lead interference. Odds ratios were used to describe the association with moderate (VC width ≥ 0.5 cm) or severe (VC width ≥ 0.7 cm) TR, separately, using bivariate and stepwise multivariate logistic regression analysis. Results Forty-five of 100 patients showed device lead tricuspid valve leaflet interference. The septal leaflet was the most commonly affected (23 patients). On bivariate analysis, preimplantation VC width, right atrial size, tricuspid annular diameter, and lead-leaflet interference were significantly associated with postdevice TR. On multivariate analysis, preimplantation VC width and the presence of an interfering lead were independently associated with postdevice TR. Furthermore, the presence of an interfering lead was the only factor associated with TR worsening, increasing the likelihood of developing moderate or severe TR by 15- and 11-fold, respectively. Conclusion Lead-leaflet interference as seen on 3D echocardiography is associated with TR after device lead placement, suggesting that 3D echocardiography should be used to assess for

  16. Severe Tricuspid Regurgitation Diagnosed 13 Years after a Car Accident: A Case Report

    PubMed Central

    Acar, Burak; Suleymanoglu, Muhammed; Burak, Cengiz; Demirkan, Burcu Mecit; Guray, Yesim; Tufekcioglu, Omac; Aydogdu, Sinan

    2015-01-01

    Abstract Blunt chest traumas mostly occur due to car accidents and can cause many cardiac complications such as septal rupture, free-wall rupture, coronary artery dissection or thrombosis, heart failure, arrhythmias, and chordae and papillary muscle rupture. One of the most serious complication is tricuspid regurgitation (TR), which can be simply diagnosed by physical examination and confirmed by echocardiography. We describe a 48-year-old female patient, diagnosed with severe TR 13 years after a blunt chest trauma due to a car accident. TR was diagnosed with transthoracic echocardiography and three dimensional transthoracic echocardiography had defined the exact pathology of the tricuspid valve. The patient underwent successful surgery with bioprosthetic valve implantation and was discharged at 6th postoperative day without any complication. The patient had no problem according to the follow-up one month and six months after operation. PMID:26157464

  17. Obstructed bi-leaflet prosthetic mitral valve imaging with real-time three-dimensional transesophageal echocardiography.

    PubMed

    Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi

    2015-01-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.

  18. Effect of obstructive sleep apnea on mitral valve tenting.

    PubMed

    Pressman, Gregg S; Figueredo, Vincent M; Romero-Corral, Abel; Murali, Ganesan; Kotler, Morris N

    2012-04-01

    Obstructive apneas produce high negative intrathoracic pressure that imposes an afterload burden on the left ventricle. Such episodes might produce structural changes in the left ventricle over time. Doppler echocardiograms were obtained within 2 months of attended polysomnography. Patients were grouped according to apnea-hypopnea index (AHI): mild/no obstructive sleep apnea (OSA; AHI <15) and moderate/severe OSA (AHI ≥15). Mitral valve tenting height and area, left ventricular (LV) long and short axes, and LV end-diastolic volume were measured in addition to tissue Doppler parameters. Comparisons of measurements at baseline and follow-up between and within groups were obtained; correlations between absolute changes (Δ) in echocardiographic parameters were also performed. After a mean follow-up of 240 days mitral valve tenting height increased significantly (1.17 ± 0.12 to 1.28 ± 0.17 cm, p = 0.001) in moderate/severe OSA as did tenting area (2.30 ± 0.41 to 2.66 ± 0.60 cm(2), p = 0.0002); Δtenting height correlated with ΔLV end-diastolic volume (rho 0.43, p = 0.01) and Δtenting area (rho 0.35, p = 0.04). In patients with mild/no OSA there was no significant change in tenting height; there was a borderline significant increase in tenting area (2.20 ± 0.44 to 2.31 ± 0.43 cm(2), p = 0.05). Septal tissue Doppler early diastolic wave decreased (8.04 ± 2.49 to 7.10 ± 1.83 cm/s, p = 0.005) in subjects with moderate/severe OSA but not in in those with mild/no OSA. In conclusion, in patients with moderate/severe OSA, mitral valve tenting height and tenting area increase significantly over time. This appears to be related, at least in part, to changes in LV geometry. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Revisit of Functional Tricuspid Regurgitation; Current Trends in the Diagnosis and Management

    PubMed Central

    Muraru, Denisa; Surkova, Elena

    2016-01-01

    Current knowledge of functional tricuspid regurgitation (FTR) as a progressive entity, worsening the prognosis of patients irrespective of its aetiology, has led to renewed interest in the pathophysiology and assessment of FTR. For the proper management of FTR, not only its severity, but also the mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and leaflet tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. A better assessment of the anatomy and function of tricuspid apparatus and tricuspid regurgitation severity should help with the appropriate selection of patients who will benefit from either surgical tricuspid valve repair/replacement or a percutaneous procedure, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. In this article, we review the anatomy, pathophysiology and the use of imaging techniques to assess patients with FTR, as well as the various treatment options for FTR, including emerging transcatheter procedures. The limitations affecting the current approach to FTR patients and the unmet clinical needs for their management have also been discussed. PMID:27482252

  20. Live/real time three-dimensional transthoracic echocardiographic assessment of tricuspid valve pathology: incremental value over the two-dimensional technique.

    PubMed

    Pothineni, Koteswara R; Duncan, Kurt; Yelamanchili, Pridhvi; Nanda, Navin C; Patel, Vinod; Fan, PoHoey; Burri, Manjula V; Singh, Anurag; Panwar, Sadik R

    2007-05-01

    Twenty-nine patients with different tricuspid valve (TV) pathologies were studied by both two-dimensional transthoracic (2DTTE) and live/real time three-dimensional transthoracic echocardiography (3DTTE). A major contribution of 3DTTE over 2DTTE was the en face visualization of all three leaflets of the TV in all patients. This allowed accurate assessment of TV orifice area in patients with TV stenosis and carcinoid disease. Loss of TV leaflet tissue, defects in TV leaflets and size of TV systolic non-coaptation could also be delineated and resulted in identifying the mechanism of tricuspid regurgitation (TR) in patients with Ebstein's anomaly and rheumatic heart disease. Prolapse of TV leaflets could also be well visualized and enabled us to develop a schema for systematic assessment of individual segment prolapse which could help in surgical planning. The exact sites of chordae rupture in patients with flail TV as well as right ventricular papillary muscle rupture could be well seen by 3DTTE. 3DTTE also permitted sectioning of various TV masses for more specific diagnosis of their nature. In addition, color Doppler 3DTTE provided an estimate of quantitative evaluation of TR severity, since the exact shape and size of the vena contracta could be accurately assessed. In conclusion, our preliminary experience with 3DTTE has demonstrated substantial incremental value over 2DTTE in the assessment of various TV pathologies.

  1. Anterior Urethral Valve: A Rare But an Important Cause of Infravesical Urinary Tract Obstruction.

    PubMed

    Parmar, Jitendra P; Mohan, Chander; Vora, Maulik P

    2016-01-01

    Urethral valves are infravesical congenital anomalies, with the posterior urethral valve (PUV) being the most prevalent one. Anterior urethral valve (AUV) is a rare but a well-known congenital anomaly. AUV and diverticula can cause severe obstruction, whose repercussions on the proximal urinary system can be important. Few cases have been described; both separately and in association with urethral diverticulum. The presentation of such a rare but important case led us to a report with highlighting its classic imaging features. We present a case report of AUV with lower urinary tract symptoms in a 6-year-old boy with complaints of a poor stream of urine and strain to void. Unique findings were seen on Retrograde Urethrography (RGU) and Voiding Cysto-Urethrography (VCUG), i.e. linear incomplete filling defect in the penile urethra and associated mild dilatation of the anterior urethra ending in a smooth bulge. On cysto-urethroscopy the anterior urethral valve was confirmed and fulguration was done. Congenital anterior urethral valve is an uncommon but important cause of infravesical lower urinary tract obstruction that is more common in male urethra. It can occur as an isolated AUV or in association with diverticulum and VATER anomalies. Early diagnosis and management of this rare condition is very important to prevent further damage, infection and vesicoureteral reflux. AUV may be associated with other congenital anomalies of the urinary system; therefore a full evaluation of the urinary system is essential.

  2. Validation of continuous-wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study.

    PubMed

    Wilkins, G T; Gillam, L D; Kritzer, G L; Levine, R A; Palacios, I F; Weyman, A E

    1986-10-01

    For patients with stenotic native valves, the modified Bernoulli equation (delta P = 4V2) may be applied to Doppler-measured transvalvular velocities to yield an accurate estimate of transvalvular gradients. Although it would be useful if the same approach could be used for those with stenotic prosthetic valves, no previous study has validated the Doppler technique in this setting. We therefore recorded simultaneous continuous-wave Doppler flow profiles and transvalvular manometric gradients in 12 catheterized patients in whom all atrial and ventricular pressures were directly measured (transseptal left atrial catheterization and transthoracic ventricular puncture were performed where necessary). A total of 13 prostheses were studied: 11 mitral (seven porcine, three Starr-Edwards, and one Björk-Shiley) and two tricuspid (one porcine and one Björk-Shiley). The Doppler-determined mean gradient was calculated as the mean of the instantaneous gradients (delta P = 4V2) at 10 msec intervals throughout diastole. The correlation of simultaneous Doppler (DMG) and manometric mean gradients (MG) for the whole group (n = 13) demonstrated a highly significant relationship (MG = 1.07 DMG + 0.28; r = .96, p = .0001). The correlation was equally good for porcine valves alone (n = 8) (MG = 1.06 DMG + 0.55; r = .96, p = .001) and for mechanical valves alone (n = 5) (MG = 1.06 DMG - 0.04; r = .93, p = .02). In a subset of patients without regurgitation (n = 8), prosthetic valve areas were estimated by two Doppler methods originally described by Holen and Hatle, as well as by the invasive Gorlin method. As expected from theoretical considerations, a close correlation was not demonstrated between results of the Gorlin method and those of either Hatle's Doppler method (r = .65, fp = NS) or Holen's method (r = .14, p = NS). Comparison of the results of the two Doppler methods yielded a somewhat closer correlation (r = .73, p less than or equal to .05). These results suggest that in

  3. Right ventricular reduction for repair of functional tricuspid valve regurgitation: one-year follow up.

    PubMed

    Ouda, Ahmed; Matschke, Klaus; Ghazy, Tamer; Speiser, Uwe; Alexiou, Konstantin; Tugtekin, Sems-Malte; Schoen, Steffen; Kappert, Utz

    2013-09-01

    The study aim was to assess the impact of reducing the right ventricular (RV) cavity in order to optimize the outcome of tricuspid valve (TV) repair in cases of functional tricuspid regurgitation (FTR) with dilated right ventricle. Between May 2007 and February 2010, a total of 17 patients (six males, 11 females; mean age 69.5 +/- 10.1 years; mean logistic EuroSCORE 24 +/- 13%) with severe FTR and severe RV dilation were included. Echocardiography and magnetic resonance imaging (MRI) were performed for geometric assessment of the right ventricle. Intraoperatively, the lateral RV free wall was plicated to reduce the RV cavum to approximate the papillary muscles and decrease tethering of the TV; a conventional ring annuloplasty was then performed. Follow up included echocardiography and MRI at one month and one year postoperatively. The mean operative time was 157 +/- 30 min, and the cross-clamp time 63 13 min. Postoperatively, the mean bleeding volume was 486 +/- 455 ml, the rethoracotomy rate 5.9%, intensive therapy unit (ITU) stay 6.0 +/- 4.4 days, and hospital stay 19.0 +/- 8.8 days. In-hospital mortality was 17.6%. The mean follow up was 14.4 +/- 2.4 months. The one-year follow up revealed a survival of 82.3%, a slight decrease in RV ejection fraction (from 33.5 +/- 4.2% to 31.7 +/- 5.7%; p = 0.13), a significant reduction in the RV end-diastolic volume index (from 160 +/- 15.6 to 128 +/- 10 ml/m2; p = 0.0001), a reduction in TV tenting area (from 3.3 +/- 0.9 to 0.9 +/- 0.3 cm2; p = 0.0001), and a significant reduction in the ratio of TR jet to right atrial surface area (from 54.8 +/- 8.2% to 14.1 +/- 3.5%; p = 0.0001). In cases of FTR, RV dilation may be considered as a correctable factor at subvalvular level to optimize the outcome of TV repair.

  4. Azygos vein aneurysm resection concomitant with heart valve repair via right thoracotomy.

    PubMed

    Suzuki, Yota; Kaji, Masahiro; Hirose, Shigemichi; Ohtsubo, Satoshi

    2016-12-01

    Azygos vein aneurysm is very rare and is usually found incidentally because of its clinical silence. We report a case of recurrent pleural effusion caused by an azygos vein aneurysm in a patient with moderate mitral valve regurgitation (MR) and tricuspid valve regurgitation (TR). Since valve disease is considered a significant precipitating factor for both dyspnoea and pleural effusion, we decided to study the aetiologies of these conditions concomitantly. Azygos vein aneurysm resection in combination with tricuspid and mitral valve repair using cardiopulmonary bypass was performed successfully through a right anterior thoracotomy. The postoperative course was uneventful, and the patient reported improved exercise capacity. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Prevalence and mechanism of tricuspid regurgitation following implantation of endocardial leads for pacemaker or cardioverter-defibrillator.

    PubMed

    Al-Mohaissen, Maha A; Chan, Kwan Leung

    2012-03-01

    Endocardial lead-induced tricuspid regurgitation has not been well recognized, either clinically or echocardiographically, and yet it is likely a preventable iatrogenic disease. In severe cases, it can lead to right ventricular failure and require tricuspid valve surgery. This complication will become increasingly important, because the numbers of permanent pacemakers and implantable cardioverter-defibrillators are expected to increase because of the aging population and the expanding capabilities of these devices. Published studies are largely retrospective, and serial studies to assess the time course of the development of tricuspid regurgitation are lacking. The mechanisms and severity of tricuspid regurgitation may not be well evaluated by two-dimensional echocardiography. Real-time three-dimensional echocardiography appears to be a promising technique to evaluate the mechanism of tricuspid regurgitation and may allow the early detection of patients who will develop severe lead-induced tricuspid regurgitation. A better understanding of the mechanism of lead-induced tricuspid regurgitation will be essential to the development of preventive strategies, which can then be tested in future clinical trials. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  6. Functional Aortic Root Parameters and Expression of Aortopathy in Bicuspid Versus Tricuspid Aortic Valve Stenosis.

    PubMed

    Girdauskas, Evaldas; Rouman, Mina; Disha, Kushtrim; Fey, Beatrix; Dubslaff, Georg; Theis, Bernhard; Petersen, Iver; Gutberlet, Matthias; Borger, Michael A; Kuntze, Thomas

    2016-04-19

    The correlation between bicuspid aortic valve (BAV) disease and aortopathy is not fully defined. This study aimed to prospectively analyze the correlation between functional parameters of the aortic root and expression of aortopathy in patients undergoing surgery for BAV versus tricuspid aortic valve (TAV) stenosis. From January 1, 2012 through December 31, 2014, 190 consecutive patients (63 ± 8 years, 67% male) underwent aortic valve replacement ± proximal aortic surgery for BAV stenosis (n = 137, BAV group) and TAV stenosis (n = 53, TAV group). All patients underwent pre-operative cardiac magnetic resonance imaging to evaluate morphological/functional parameters of the aortic root. Aortic tissue was sampled during surgery on the basis of the location of eccentric blood flow contact with the aortic wall, as determined by cardiac magnetic resonance (i.e., jet sample and control sample). Aortic wall lesions were graded using a histological sum score (0 to 21). The largest cross-sectional aortic diameters were at the mid-ascending level in both groups and were larger in BAV patients (40.2 ± 7.2 mm vs. 36.6 ± 3.3 mm, respectively, p < 0.001). The histological sum score was 2.9 ± 1.4 in the BAV group versus 3.4 ± 2.6 in the TAV group (p = 0.4). The correlation was linear and comparable between the maximum indexed aortic diameter and the angle between the left ventricular outflow axis and aortic root (left ventricle/aorta angle) in both groups (BAV group: r = 0.6, p < 0.001 vs. TAV group r = 0.45, p = 0.03, z = 1.26, p = 0.2). Logistic regression identified the left ventricle/aorta angle as an indicator of indexed aortic diameter >22 mm/m(2) (odds ratio: 1.2; p < 0.001). Comparable correlation patterns between functional aortic root parameters and expression of aortopathy are found in patients with BAV versus TAV stenosis. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Right ventriculography as a valid method for the diagnosis of tricuspid insufficiency.

    PubMed

    Ubago, J L; Figueroa, A; Colman, T; Ochoteco, A; Rodríguez, M; Durán, C M

    1981-01-01

    The value of right ventriculography in the diagnosis of tricuspid insufficiency (TI) is often questioned because of 1) the high incidence of premature ventricular contractions (PVCs) during injections and 2) interference of the catheter in the valve closure mechanism. In 168 patients a commercially available, not preshaped, balloon-tipped catheter was used for right ventriculography. To avoid the induction of PVCs, the catheter tip was placed in the middle third of the diafragmatic wall of the right ventricle, and the balloon was inflated, becoming trapped by the trabeculae. In this position the catheter's side holes should be located in the inflow chamber. To ensure this correct position, and therefore lack of ectopic beats during angiography, a saline test injection was performed previously in every case. With this technique the incidence of PVCs during ventriculography was only 7.7%. In all but one case, such beats were isolated. The 168 patients were divided into three groups according to their likelihood of experiencing tricuspid interference by the catheter: group 1 included 41 patients with a normal heart or with coronary artery disease. No one from this group had TI. Of group II, 28 patients with right ventricular pressure or volume overload or cardiomyopathy, only 2 had TI, both with a previous clinical diagnosis of regurgitation. Group III contained 99 patients with rheumatic heart disease. Thirty-five of them showed angiographic TI, and 24 of these had this diagnosis confirmed either clinically or at surgery. It is felt that this technique of right ventriculography, with its low incidence of PVCs and slight interference with tricuspid closure, is a valid method for the objective study of the tricuspid valve.

  8. A repositionable valved stent for endovascular treatment of deteriorated bioprostheses.

    PubMed

    Zegdi, Rachid; Khabbaz, Ziad; Borenstein, Nicolas; Fabiani, Jean-Noël

    2006-10-03

    We report our animal experience of endovascular valve replacement (VR) of failed bioprosthesis (BP) using an original delivery catheter allowing repositioning of the valved stent (VS). Among the different devices designed for percutaneous VR, none has the potential for repositioning of a fully deployed VS. Five sheep underwent, on beating heart, tricuspid VR with a stented BP. Prolapse of 1 leaflet was induced by tearing. For the endovascular tricuspid VR, we used a VS constructed with a nitinol self-expandable stent and a porcine stentless aortic valve. We also used an original delivery catheter, allowing repositioning of the VS through a compression or relaxation mechanism of the stent. Epicardial echocardiography and right ventriculography showed severe tricuspid regurgitation, with a regurgitant jet extending to the inferior vena cava. After surgical exposure to the infrarenal inferior vena cava, the VS was successfully implanted inside the failed BP in all cases. Repositioning of the fully deployed VS was always possible. Echocardiographic and macroscopic studies revealed adequate VS positioning, excellent leaflet opening, and absence of any intraprosthetic or periprosthetic leak. Endovascular VR was easily performed in sheep with failed BP in the tricuspid position. The novel delivery catheter allowed adequate repositioning of our fully deployed VS before its definitive release. One may anticipate that the safety improvement conferred by this new technology will certainly favor the development of percutaneous VR in clinical practice.

  9. Mechanism and Implications of the Tricuspid Regurgitation: From the Pathophysiology to the Current and Future Therapeutic Options.

    PubMed

    Mangieri, Antonio; Montalto, Claudio; Pagnesi, Matteo; Jabbour, Richard J; Rodés-Cabau, Josep; Moat, Neil; Colombo, Antonio; Latib, Azeem

    2017-07-01

    The tricuspid valve was virtually ignored for a long time in the past. However, significant tricuspid regurgitation (TR) often accompanies left-side heart valve pathology and does not always reverse with its correction. If left untreated, TR can progress and result in progressive right ventricular failure. Current guideline recommendations still hold minor differences. Nevertheless, there is a consensus to operate on patients with severe TR undergoing left-sided valve surgery (class I) or those with mild to moderate TR with a dilated annulus (≥40 or ≥21 mm 2 , Class IIa). However, in case of the primary TR, surgical options is limited by a relatively high risk of mortality and morbidity. For these patients, new percutaneous approaches are becoming available but no long-term data are still available. In this review, we provide a comprehensive overview of the epidemiological and pathophysiological aspects of TR, and the current and future directions of therapy. © 2017 American Heart Association, Inc.

  10. Mitral valve replacement complicated by iatrogenic left ventricular outflow obstruction and paravalvular leak: case report and review of literature.

    PubMed

    Lee, Justin Z; Tey, Kai R; Mizyed, Ahmad; Hennemeyer, Charles T; Janardhanan, Rajesh; Lotun, Kapildeo

    2015-10-09

    Left ventricular outflow tract (LVOT) obstruction and paravalvular leak (PVL) are relatively uncommon, but are serious complications of prosthetic valve replacement. We present a case that displays the unique therapeutic challenges of treating a patient who developed both LVOT obstruction and mitral PVL after undergoing surgical aortic and mitral valve replacement (MVR). We also describe the use of alcohol septal ablation and albumin-glutaraldehyde (BioGlue) for septal ablation to percutaneously treat the patient's LVOT obstruction, followed by use of an Amplatzer vascular plug for percutaneous closure of an antero-medial mitral PVL associated with severe regurgitation. Percutaneous interventional management of these entities may be considered as an initial therapeutic option, especially in high-risk patients with significant morbidity and mortality of repeat surgical operations.

  11. Tricuspid Regurgitation Does Not Impact Right Ventricular Remodeling After Percutaneous Pulmonary Valve Implantation.

    PubMed

    Tanase, Daniel; Ewert, Peter; Georgiev, Stanimir; Meierhofer, Christian; Pabst von Ohain, Jelena; McElhinney, Doff B; Hager, Alfred; Kühn, Andreas; Eicken, Andreas

    2017-04-10

    This study sought to investigate the impact of tricuspid regurgitation (TR) on right ventricular function after percutaneous pulmonary valve implantation (PPVI). PPVI provides a less invasive alternative to surgery in patients with right ventricular-to-pulmonary artery (RV-PA) conduit dysfunction. Recovery of the right ventricle has been described after PPVI for patients with pulmonary stenosis and for those with pulmonary regurgitation. Additional TR enforces RV dysfunction by supplemental volume overload. Limited data are available on the potential of the right ventricle to recover in such a specific hemodynamic situation. In a matched cohort study, we compared patients who underwent PPVI with additional TR with those without TR. The degree of TR improved in 83% of the patients. In our patients (n = 36) exercise capacity and right ventricular volume index improved similarly 6 months after PPVI in patients with and without important TR. None of them had significant TR in the long-term follow-up of median 78 months. PPVI improves not only RV-PA-conduit dysfunction, but also concomitant TR. In patients with a dysfunctional RV-PA conduit and TR, the decision whether to fix TR should be postponed after PPVI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Tricuspid Regurgitation – Medical Management and Evolving Interventional Concepts

    PubMed Central

    Beckhoff, Frederik; Alushi, Brunilda; Jung, Christian; Navarese, Eliano; Franz, Marcus; Kretzschmar, Daniel; Wernly, Bernhard; Lichtenauer, Michael; Lauten, Alexander

    2018-01-01

    Severe tricuspid regurgitation (TR) is a complex condition of the right ventricle (RV) and tricuspid valve apparatus and is frequently associated with symptomatic heart failure and a significant morbidity and mortality. In these patients, left heart pathologies lead to chronic pressure overload of the RV, eventually causing progressive RV dilatation and functional TR. Therefore, TR cannot be considered as isolated heart valve disease pathology but has to be understood and treated as one component of a complex structural RV pathology and is frequently also a marker of an advanced stage of cardiac disease. In these patients, medical therapy restricted to diuretics and heart failure medication is frequently ineffective. Also, severe TR in the setting of advanced heart failure constitutes a high risk for cardiac surgery. Neither one of these treatment options has demonstrated a beneficial effect on long-term prognosis. The recent innovations in transcatheter technology led to efforts to develop interventional approaches to severe TR. Multiple innovative treatment concepts are currently under preclinical and clinical investigation to replace or repair TV function. However, up to date none of these approaches is established and there is still a lack of clinical data to support the efficacy of transcatheter TR treatment. PMID:29892601

  13. A Sickle Cell Disease Patient with Severe Tricuspid Regurgitation and Early Developed Pulmonary Hypertension.

    PubMed

    Vaidya, Gaurang; Sarwar, Muhammad; Sun, Zongxia; Wei, Tiemin; Liu, Kan

    2015-01-01

    Pulmonary hypertension (PH) worsens the mortality of the patients with sickle cell disease (SCD). The exact mechanism of PH development/progression in SCD, including the role of tricuspid regurgitation (TR), remains unclear. We herein report an unusual SCD case, complicated by chronic thromboembolic disorder, who developed severe TR and an accelerated progression of PH. Tricuspid valve surgery significantly ameliorated the patient's symptoms and reduced hospital readmission. The early detection and management of the reversible disorder accelerating the PH development in SCD patients may alter the clinical course, improve the quality of life, and potentially affect the long-term outcome.

  14. Prevalence of mitral valve regurgitation in 79 asymptomatic Norfolk terriers.

    PubMed

    Bodegård-Westling, A; Tidholm, A; Häggström, J

    2017-04-01

    To determine the prevalence of mitral valve regurgitation (MR) in asymptomatic Swedish Norfolk terriers. Seventy-nine privately owned Norfolk terriers. A prospective observational study was conducted where dogs were recruited via the Swedish Norfolk terrier club. All dogs were examined using the same protocol including physical examination and Doppler echocardiography. Fifteen dogs (19%) had a murmur at the time of the examination. A total of 35 dogs (44%) had MR, including 23 dogs (29%) with both MR and tricuspid valve regurgitation and 12 dogs (15%) with MR only, identified on Doppler echocardiography. In addition, 7 dogs (9%) had tricuspid valve regurgitation only. The prevalence of MR increased with increasing age (p < 0.0001). Mitral valve regurgitation is common in asymptomatic Norfolk terriers with and without murmurs and the prevalence increases with age. The impact of MR in this breed on survival remains to be elucidated by a longitudinal study. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Steady flow hemodynamic and energy loss measurements in normal and simulated calcified tricuspid and bicuspid aortic valves.

    PubMed

    Seaman, Clara; Akingba, A George; Sucosky, Philippe

    2014-04-01

    The bicuspid aortic valve (BAV), which forms with two leaflets instead of three as in the normal tricuspid aortic valve (TAV), is associated with a spectrum of secondary valvulopathies and aortopathies potentially triggered by hemodynamic abnormalities. While studies have demonstrated an intrinsic degree of stenosis and the existence of a skewed orifice jet in the BAV, the impact of those abnormalities on BAV hemodynamic performance and energy loss has not been examined. This steady-flow study presents the comparative in vitro assessment of the flow field and energy loss in a TAV and type-I BAV under normal and simulated calcified states. Particle-image velocimetry (PIV) measurements were performed to quantify velocity, vorticity, viscous, and Reynolds shear stress fields in normal and simulated calcified porcine TAV and BAV models at six flow rates spanning the systolic phase. The BAV model was created by suturing the two coronary leaflets of a porcine TAV. Calcification was simulated via deposition of glue beads in the base of the leaflets. Valvular performance was characterized in terms of geometric orifice area (GOA), pressure drop, effective orifice area (EOA), energy loss (EL), and energy loss index (ELI). The BAV generated an elliptical orifice and a jet skewed toward the noncoronary leaflet. In contrast, the TAV featured a circular orifice and a jet aligned along the valve long axis. While the BAV exhibited an intrinsic degree of stenosis (18% increase in maximum jet velocity and 7% decrease in EOA relative to the TAV at the maximum flow rate), it generated only a 3% increase in EL and its average ELI (2.10 cm2/m2) remained above the clinical threshold characterizing severe aortic stenosis. The presence of simulated calcific lesions normalized the alignment of the BAV jet and resulted in the loss of jet axisymmetry in the TAV. It also amplified the degree of stenosis in the TAV and BAV, as indicated by the 342% and 404% increase in EL, 70% and 51% reduction

  16. Impact of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mechanical mitral valve replacement for rheumatic mitral valve disease.

    PubMed

    Wang, Bin; Xu, Zhi-yun; Han, Lin; Zhang, Guan-xin; Lu, Fang-lin; Song, Zhi-gang

    2013-03-01

    The prognostic significance of preoperative atrial fibrillation on mitral valve replacement remains unclear. The aim of this study was to explore the effects of the presence of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mitral valve replacement for rheumatic valve disease. A retrospective analysis was performed on a total of 793 patients who underwent mitral valve replacement with or without tricuspid valve repair in our hospital. The patients selected were divided into two groups according to preoperative rhythm status. Patients with preoperative atrial fibrillation were assigned to the AF group, while patients in preoperative sinus rhythm were assigned to the SR group. Postoperative follow-up was performed by outpatient visits, as well as by telephone and written correspondence. Data gathered included survivorship, postoperative complications, left ventricular function and tricuspid regurgitation. For patients with atrial fibrillation vs those in sinus rhythm, there was no difference in postoperative mortality and morbidity. Follow-up was a mean of 8.6 ± 2.4 years. For patients with preoperative atrial fibrillation, 10-year survival from a Kaplan-Meier curve was 88.7%, compared with 96.6% in patients with preoperative sinus rhythm (P = 0.002). Multivariate analysis identified low left ventricular ejection fraction, older age, large left atrium and preoperative atrial fibrillation as significant adverse predictors for overall survival. Freedom from thromboembolism complications at 13 years was lower for patients with preoperative atrial fibrillation without maze procedure and left atrial appendage ligation, compared with that for patients with preoperative sinus rhythm without maze procedure and left atrial appendage ligation, and patients with concomitant maze procedure and left atrial appendage ligation (76.3 vs 94.8 vs 94.0%, respectively; P = 0.001). On echocardiography, the proportion of patients with significant tricuspid

  17. [Doppler echocardiography of tricuspid insufficiency. Methods of quantification].

    PubMed

    Loubeyre, C; Tribouilloy, C; Adam, M C; Mirode, A; Trojette, F; Lesbre, J P

    1994-01-01

    Evaluation of tricuspid incompetence has benefitted considerably from the development of Doppler ultrasound. In addition to direct analysis of the valves, which provides information about the mechanism involved, this method is able to provide an accurate evaluation, mainly through use of the Doppler mode. In addition to new criteria being evaluated (mainly the convergence zone of the regurgitant jet), some indices are recognised as good quantitative parameters: extension of the regurgitant jet into the right atrium, anterograde tricuspid flow, laminar nature of the regurgitant flow, analysis of the flow in the supra-hepatic veins, this is only semi-quantitative, since the calculation of the regurgitation fraction from the pulsed Doppler does not seem to be reliable; This accurate semi-quantitative evaluation is made possible by careful and consistent use of all the criteria available. The authors set out to discuss the value of the various evaluation criteria mentioned in the literature and try to define a practical approach.

  18. The natural history of congenitally corrected transposition of the great arteries.

    PubMed

    Huhta, James

    2011-01-01

    The natural history of congenitally corrected transposition of the great arteries is of clinical/surgical importance once the fetus is born without heart block or signs of heart failure. Without significant tricuspid valve malformation, associated defects such as ventricular septal defect and left ventricular outflow obstruction can be repaired surgically. The mortality and long-term outcome appear to be linked strongly with the severity of tricuspid valve regurgitation. Some patients with an intact ventricular septum and no right ventricular dysfunction will live long lives without detection, and some women will successfully complete pregnancy.

  19. Contemporary management of tricuspid regurgitation: an updated clinical review.

    PubMed

    Taylor, Joshua T; Chidsey, Geoffrey; Disalvo, Thomas G; Byrne, John G; Maltais, Simon

    2013-01-01

    Tricuspid regurgitation (TR) is a complex and insidious valvular pathology that represents a complex decision and management algorithm for patients. TR is present in a significant proportion of the population and is especially prevalent in patients with advanced heart failure. Patients with TR have been demonstrated to have a decreased survival even with normal left heart function. TR can be a result of pathology that directly affects the valvular structure (i.e., Ebstein anomaly) or as a result of increased forward pressures (ie, pulmonary hypertension, left heart failure). Conservative management of patients with TR is primarily symptomatic relief. Definitive therapy involves surgical repair of the tricuspid valve. Furthermore, as more patients develop advanced heart failure, the management of TR in patients with left ventricular assist devices has become necessary because of the evidence of increased in-hospital morbidity and a trend toward decreased survival.

  20. Predictors of Severe Tricuspid Regurgitation in Patients with Permanent Pacemaker or Automatic Implantable Cardioverter-Defibrillator Leads

    PubMed Central

    Najib, Mohammad Q.; Vittala, Satya S.; Challa, Suresh; Raizada, Amol; Tondato, Fernando J.; Lee, Howard R.; Chaliki, Hari P.

    2013-01-01

    Patients with permanent pacemaker or automatic implantable cardioverter-defibrillator (AICD) leads have an increased prevalence of tricuspid regurgitation. However, the roles of cardiac rhythm and lead-placement duration in the development of severe tricuspid regurgitation are unclear. We reviewed echocardiographic data on 26 consecutive patients who had severe tricuspid regurgitation after permanent pacemaker or AICD placement; before treatment, they had no organic tricuspid valve disease, pulmonary hypertension, left ventricular dysfunction, or severe tricuspid regurgitation. We compared the results to those of 26 control subjects who had these same devices but no more than mild tricuspid regurgitation. The patients and control subjects were similar in age (mean, 81 ±6 vs 81 ±8 yr; P = 0.83), sex (male, 42% vs 46%; P = 0.78), and left ventricular ejection fraction (0.60 ±0.06 vs 0.58 ± 0.05; P = 0.4). The patients had a higher prevalence of atrial fibrillation (92% vs 65%; P=0.01) and longer median duration of pacemaker or AICD lead placement (49.5 vs 5 mo; P < 0.001). After adjusting for age, sex, and right ventricular systolic pressure by multivariate logistic regression analysis, we found that atrial fibrillation (odds ratio=6.4; P = 0.03) and duration of lead placement (odds ratio=1.5/yr; P = 0.001) were independently associated with severe tricuspid regurgitation. Out study shows that atrial fibrillation and longer durations of lead placement might increase the risk of severe tricuspid regurgitation in patients with permanent pacemakers or AICDs. PMID:24391312

  1. Tropheryma whipplei tricuspid endocarditis: a case report and review of the literature.

    PubMed

    Gabus, Vincent; Grenak-Degoumois, Zita; Jeanneret, Severin; Rakotoarimanana, Riana; Greub, Gilbert; Genné, Daniel

    2010-08-04

    The main clinical manifestations of Whipple's disease are weight loss, arthropathy, diarrhea and abdominal pain. Cardiac involvement is frequently described. However, endocarditis is rare and is not usually the initial presentation of the disease. To the best of our knowledge, this is the first reported case of a patient with Tropheryma whipplei tricuspid endocarditis without any other valve involved and not presenting signs of arthralgia and abdominal involvement. We report a case of a 50-year-old Caucasian man with tricuspid endocarditis caused by Tropheryma whipplei, showing signs of severe shock and an absence of other more classic clinical signs of Whipple's disease, such as arthralgia, abdominal pain and diarrhea. Tropheryma whipplei was documented by polymerase chain reaction of the blood and pleural fluid. The infection was treated with a combined treatment of doxycycline, hydroxychloroquine and sulfamethoxazole-trimethoprim for one year. Tropheryma whipplei infectious endocarditis should always be considered when facing a blood-culture negative endocarditis particularly in right-sided valves. Although not standardized yet, treatment of Tropheryma whipplei endocarditis should probably include a bactericidal antibiotic (such as doxycycline) and should be given over a prolonged period of time (a minimum of one year).

  2. Systolic Anterior Motion of the Mitral Valve after Mitral Valve Repair

    PubMed Central

    Sternik, Leonid; Zehr, Kenton J.

    2005-01-01

    Factors predisposing patients to systolic anterior motion of the mitral valve (SAM) with left ventricular outflow tract (LVOT) obstruction after mitral valve repair are the presence of a myxomatous mitral valve with redundant leaflets, a nondilated hyperdynamic left ventricle, and a short distance between the mitral valve coaptation point and the ventricular septum after repair. From December 1999 through March 2000, we used our surgical method in 6 patients with severely myxomatous regurgitant mitral valves who were at risk of developing SAM. Leaflets were markedly redundant in all 6. Left ventricular function was hyperdynamic in 4 patients and normal in 2. Triangular or quadrangular resection of the midportion of the posterior leaflet and posterior band annuloplasty were performed. To prevent SAM and LVOT obstruction, extra, posteriorly directed, mid-posterior-leaflet secondary chordae tendineae, which would otherwise have been resected, were transferred to the underside of the middle of the mid-anterior leaflet with a small piece of associated valve as an anchoring pledget. This kept the redundant anterior leaflet edge, which extended below the coaptation point, away from the LVOT. No post-repair SAM or LVOT obstruction was observed on intraoperative or discharge echocardiography. All patients had no or trivial residual mitral regurgitation. We conclude that extra chordae tendineae, when available, can be used in mitral valve repair to tether the redundant anterior leaflet and thus prevent it from flipping into the LVOT. This will theoretically prevent SAM and LVOT obstruction in patients with risk factors for SAM. PMID:15902821

  3. Direct injury to right coronary artery in patients undergoing tricuspid annuloplasty.

    PubMed

    Díez-Villanueva, Pablo; Gutiérrez-Ibañes, Enrique; Cuerpo-Caballero, Gregorio P; Sanz-Ruiz, Ricardo; Abeytua, Manuel; Soriano, Javier; Sarnago, Fernando; Elízaga, Jaime; González-Pinto, Angel; Fernández-Avilés, Francisco

    2014-04-01

    Direct injury to the right coronary artery as a result of reparative operation on the tricuspid valve is a rare, probably underdiagnosed, but serious complication, which often involves dramatic clinical consequences. So far, only five cases have been described in the literature. We describe our single-center experience of this complication, and review and analyze relevant clinical and anatomic considerations related to this entity. Cases previously reported in the literature were also reviewed. We describe four cases of direct injury to the right coronary artery in patients undergoing tricuspid annuloplasty (DeVega annuloplasty, 3; ring annuloplasty, 1) in our institution since 2005. All patients had right ventricular dilatation and severely dilated tricuspid annulus. Right coronary artery occlusion always occurred between the right marginal artery and the crux of the heart. Patients presented with hemodynamic or electrical instability. Coronary flow could be restored in 2 patients (percutaneously 1; surgically 1), both of whom finally survived, while it was not technically possible in the other 2 (1 died). Occlusion of the right coronary artery in patients undergoing tricuspid annuloplasty is a rare complication that may occur if great annulus dilatation is present, thus altering both normal annular geometry and the relationship between the right coronary artery and the tricuspid annulus, particularly when DeVega annuloplasty is performed. Such an entity should be considered in the immediate postoperative period in an unstable patient, especially when complementary tests support this diagnosis. Prompt recognition and treatment can positively affect the patient's outcome, most often by means of an emergency revascularization strategy. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Respiratory exacerbation in a young adult with cystic fibrosis and tricuspid atresia.

    PubMed

    Wood, Jamie; Sawyer, Abbey; Mulrennan, Siobhain; Bullock, Andrew

    2018-07-01

    Tricuspid atresia (TAt) is a complex congenital heart defect (CHD) characterized by the absence of the tricuspid valve and right ventricular hypoplasia requiring surgery in childhood, the Fontan procedure. We present a case of a 21-year-old male with TAt and cystic fibrosis (CF), who underwent a Fontan procedure in childhood, presenting to an adult CF clinic with severe deterioration in his respiratory status and multi-organ dysfunction associated with CF. This report describes problems associated with the management of a CF respiratory exacerbation and extrapulmonary manifestations of CF in the unique situation of a Fontan circulation, a circulation with absence of a subpulmonary ventricle and pulsatile pulmonary arterial blood flow where maintenance of systemic cardiac output is totally dependent on good respiratory function and low pulmonary artery pressures.

  5. Intravalvular Implantation of Mitral Valve Prostheses

    PubMed Central

    Cooley, Denton A.; Ingram, Michael T.

    1987-01-01

    We describe a technique of intravalvular implantation of a low-profile prosthesis that has been used in nine patients with mitral valve lesions. This technique preserves the anterior and posterior chordae and papillary mechanisms, which may decrease the incidence of postoperative left ventricular dysfunction that has been noted following standard mitral valve replacement. The technique may also be useful in some patients with aortic and tricuspid regurgitation when the annulus and leaflets are relatively normal pathologically. (Texas Heart Institute Journal 1987;14:188-193) PMID:15229740

  6. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    PubMed

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  7. Successful surgical treatment of intramural aortoatrial fistula, severe aortic regurgitation, mitral prolapse, and tricuspid insufficiency in a patient with Ehlers-Danlos syndrome type IV.

    PubMed

    Jiang, Shengli; Gao, Changqing; Ren, Chonglei; Zhang, Tao

    2012-06-01

    Patients with Ehlers-Danlos syndrome (EDS) type IV, an inherited connective tissue disorder, are predisposed to vascular and digestive ruptures, and arterial ruptures account for the majority of deaths. A 31-year-old man with EDS presented with an intramural aortoatrial fistula, severe aortic regurgitation, mitral valve prolapse, and severe tricuspid valve insufficiency combined with a severely dilated left ventricle. Determining the best surgical option for the patient was not easy, especially regarding the course of action for the aortic root with a tear in the sinus of Valsalva. The fistula tract was closed at the aorta with suture and with a patch in the right atrium, the mitral valve was repaired with edge-to-edge suture and then annuloplasty with a Cosgrove ring, the aortic valve was replaced with a mechanical prosthesis, and a modified De Vega technique was used for the tricuspid valvuloplasty. The postoperative course was uncomplicated, and the patient was discharged 2 weeks later. The considerations made to arrive at the chosen surgical course of action in this complex case are reviewed.

  8. Tropheryma whipplei tricuspid endocarditis: a case report and review of the literature

    PubMed Central

    2010-01-01

    Introduction The main clinical manifestations of Whipple's disease are weight loss, arthropathy, diarrhea and abdominal pain. Cardiac involvement is frequently described. However, endocarditis is rare and is not usually the initial presentation of the disease. To the best of our knowledge, this is the first reported case of a patient with Tropheryma whipplei tricuspid endocarditis without any other valve involved and not presenting signs of arthralgia and abdominal involvement. Case presentation We report a case of a 50-year-old Caucasian man with tricuspid endocarditis caused by Tropheryma whipplei, showing signs of severe shock and an absence of other more classic clinical signs of Whipple's disease, such as arthralgia, abdominal pain and diarrhea. Tropheryma whipplei was documented by polymerase chain reaction of the blood and pleural fluid. The infection was treated with a combined treatment of doxycycline, hydroxychloroquine and sulfamethoxazole-trimethoprim for one year. Conclusion Tropheryma whipplei infectious endocarditis should always be considered when facing a blood-culture negative endocarditis particularly in right-sided valves. Although not standardized yet, treatment of Tropheryma whipplei endocarditis should probably include a bactericidal antibiotic (such as doxycycline) and should be given over a prolonged period of time (a minimum of one year). PMID:20684779

  9. Ex vivo hydrodynamics after central and paracommissural edge-to-edge technique: A further step toward transcatheter tricuspid repair?

    PubMed

    Stock, Sina; Bohm, Heidemarie; Scharfschwerdt, Michael; Richardt, Doreen; Meyer-Saraei, Roza; Tsvelodub, Stanislav; Sievers, Hans-Hinrich

    2018-03-01

    Transcatheter approaches in heart valve disease became tremendously important and are currently established in the aortic position, but transcatheter tricuspid repair is still in its beginning and remains challenging. Replicating the surgical edge-to-edge technique, for example, with the MitraClip System (Abbott Vascular, Santa Clara, Calif), represents a promising option and has been reported successfully in small numbers of cases. However, up to now, few data considering the edge-to-edge technique as a transcatheter approach are available. This study aims to determine the ex vivo hydrodynamics after the central and paracommissural edge-to-edge technique in different pathologies. Because of basal or apical dislocation of papillary muscles, leaflet prolapse or tethering was simulated in porcine tricuspid valves mounted on a flexible holding device. Central and paracommissural edge-to-edge techniques were evaluated successively in these pathologies. Regurgitant volume and mean transvalvular gradient were determined in a pulse duplicator. In this ex vivo model, the isolated edge-to-edge technique reduced tricuspid regurgitation. In the prolapse model, regurgitant volume decreased significantly after central edge-to-edge technique (from 49.4 ± 13.6 mL/stroke to 39.3 ± 14.1 mL/stroke). In the tethering model, both the central and the paracommissural edge-to-edge techniques led to a significant decrease (from 48.7 ± 13.9 to 43.6 ± 15.6 and to 41.1 ± 13.8 mL/stroke). In all cases, the reduction of regurgitant volume was achieved at the cost of significantly increased mean transvalvular gradient. This study provides a reduction of tricuspid regurgitation after the edge-to-edge technique in the specific experimental setup. Whether this reduction is sufficient to treat tricuspid regurgitation successfully in clinical practice remains to be established. Transcatheter approaches need to be evaluated further, probably with regard to concomitant annuloplasty

  10. Vector flow mapping in obstructive hypertrophic cardiomyopathy to assess the relationship of early systolic left ventricular flow and the mitral valve.

    PubMed

    Ro, Richard; Halpern, Dan; Sahn, David J; Homel, Peter; Arabadjian, Milla; Lopresto, Charles; Sherrid, Mark V

    2014-11-11

    The hydrodynamic cause of systolic anterior motion of the mitral valve (SAM) is unresolved. This study hypothesized that echocardiographic vector flow mapping, a new echocardiographic technique, would provide insights into the cause of early SAM in obstructive hypertrophic cardiomyopathy (HCM). We analyzed the spatial relationship of left ventricular (LV) flow and the mitral valve leaflets (MVL) on 3-chamber vector flow mapping frames, and performed mitral valve measurements on 2-dimensional frames in patients with obstructive and nonobstructive HCM and in normal patients. We compared 82 patients (22 obstructive HCM, 23 nonobstructive HCM, and 37 normal) by measuring 164 LV pre- and post-SAM velocity vector flow maps, 82 maximum isovolumic vortices, and 328 2-dimensional frames. We observed color flow and velocity vector flow posterior to the MVL impacting them in the early systolic frames of 95% of obstructive HCM, 22% of nonobstructive HCM, and 11% of normal patients (p < 0.001). In both pre- and post-SAM frames, we measured a high angle of attack >60° of local vector flow onto the posterior surface of the leaflets whether the flow was ejection (59%) or the early systolic isovolumic vortex (41%). Ricochet of vector flow, rebounding off the leaflet into the cul-de-sac, was noted in 82% of the obstructed HCM, 9% of nonobstructive HCM, and none (0%) of the control patients (p < 0.001). Flow velocities in the LV outflow tract on the pre-SAM frame 1 and 2 mm from the tip of the anterior leaflet were low: 39 and 43 cm/s, respectively. Early systolic flow impacts the posterior surfaces of protruding MVL initiating SAM in obstructive HCM. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Aortic Valve Stenosis Alters Expression of Regional Aortic Wall Shear Stress: New Insights From a 4-Dimensional Flow Magnetic Resonance Imaging Study of 571 Subjects.

    PubMed

    van Ooij, Pim; Markl, Michael; Collins, Jeremy D; Carr, James C; Rigsby, Cynthia; Bonow, Robert O; Malaisrie, S Chris; McCarthy, Patrick M; Fedak, Paul W M; Barker, Alex J

    2017-09-13

    Wall shear stress (WSS) is a stimulus for vessel wall remodeling. Differences in ascending aorta (AAo) hemodynamics have been reported between bicuspid aortic valve (BAV) and tricuspid aortic valve patients with aortic dilatation, but the confounding impact of aortic valve stenosis (AS) is unknown. Five hundred seventy-one subjects underwent 4-dimensional flow magnetic resonance imaging in the thoracic aorta (210 right-left BAV cusp fusions, 60 right-noncoronary BAV cusp fusions, 245 tricuspid aortic valve patients with aortic dilatation, and 56 healthy controls). There were 166 of 515 (32%) patients with AS. WSS atlases were created to quantify group-specific WSS patterns in the AAo as a function of AS severity. In BAV patients without AS, the different cusp fusion phenotypes resulted in distinct differences in eccentric WSS elevation: right-left BAV patients exhibited increased WSS by 9% to 34% ( P <0.001) at the aortic root and along the entire outer curvature of the AAo whereas right-noncoronary BAV patients showed 30% WSS increase ( P <0.001) at the distal portion of the AAo. WSS in tricuspid aortic valve patients with aortic dilatation patients with no AS was significantly reduced by 21% to 33% ( P <0.01) in 4 of 6 AAo regions. In all patient groups, mild, moderate, and severe AS resulted in a marked increase in regional WSS ( P <0.001). Moderate-to-severe AS further increased WSS magnitude and variability in the AAo. Differences between valve phenotypes were no longer apparent. AS significantly alters aortic hemodynamics and WSS independent of aortic valve phenotype and over-rides previously described flow patterns associated with BAV and tricuspid aortic valve with aortic dilatation. Severity of AS must be considered when investigating valve-mediated aortopathy. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  12. Surgical treatment of left ventricular outflow tract obstruction with apicoaortic valved conduit.

    PubMed

    Cooley, D A; Norman, J C; Reul, G J; Kidd, J N; Nihill, M R

    1976-12-01

    From Aug. 13, 1975, through May, 1976, nine patients underwent creation of a left ventricular "vent" for relief of severe left ventricular outflow tract obstruction. A Dacron fabric graft containing a heterograft valve was used to establish a conduit from the left ventricle to the abdominal aorta. There were five male and four female patients in this group; their ages ranged from 4 to 72 years. All had valvular, subvalvular, or supravalvular aortic stenosis, and all but two had undergone previous surgical procedures for relief of the stenosis. All patients survived the operation and none are receiving anticoagulant therapy. All are asymptomatic at present and follow-up is approaching one year. Postoperative cardiac catheterization studies revealed gradients across the aortic valve to be reduced by approximately 90% and mean ventricular systolic pressures by 45%. Although this concept is not new, it has not been used widely and we believe its effectiveness warrants further application.

  13. Nitric Oxide Synthase-3 Promotes Embryonic Development of Atrioventricular Valves

    PubMed Central

    Liu, Yin; Lu, Xiangru; Xiang, Fu-Li; Lu, Man; Feng, Qingping

    2013-01-01

    Nitric oxide synthase-3 (NOS3) has recently been shown to promote endothelial-to-mesenchymal transition (EndMT) in the developing atrioventricular (AV) canal. The present study was aimed to investigate the role of NOS3 in embryonic development of AV valves. We hypothesized that NOS3 promotes embryonic development of AV valves via EndMT. To test this hypothesis, morphological and functional analysis of AV valves were performed in wild-type (WT) and NOS3−/− mice at postnatal day 0. Our data show that the overall size and length of mitral and tricuspid valves were decreased in NOS3−/− compared with WT mice. Echocardiographic assessment showed significant regurgitation of mitral and tricuspid valves during systole in NOS3−/− mice. These phenotypes were all rescued by cardiac specific NOS3 overexpression. To assess EndMT, immunostaining of Snail1 was performed in the embryonic heart. Both total mesenchymal and Snail1+ cells in the AV cushion were decreased in NOS3−/− compared with WT mice at E10.5 and E12.5, which was completely restored by cardiac specific NOS3 overexpression. In cultured embryonic hearts, NOS3 promoted transforming growth factor (TGFβ), bone morphogenetic protein (BMP2) and Snail1expression through cGMP. Furthermore, mesenchymal cell formation and migration from cultured AV cushion explants were decreased in the NOS3−/− compared with WT mice. We conclude that NOS3 promotes AV valve formation during embryonic heart development and deficiency in NOS3 results in AV valve insufficiency. PMID:24204893

  14. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis.

    PubMed

    Tanis, W; Budde, R P J; van der Bilt, I A C; Delemarre, B; Hoohenkerk, G; van Rooden, J-K; Scholtens, A M; Habets, J; Chamuleau, S

    2016-02-01

    Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have additional value. This paper reviews the role of these novel imaging tools in the field of PHV obstruction and endocarditis.For acquired PHV obstruction, MDCT is of additional value in mechanical PHVs to differentiate pannus from thrombus as well as to dynamically study leaflet motion and opening/closing angles. For biological PHV obstruction, additional imaging is not beneficial as it does not change patient management. When performed on top of 2D-TTE/TEE, MDCT has additional value for the detection of both vegetations and pseudoaneurysms/abscesses in PHV endocarditis. FDG-PET has no complementary value for the detection of vegetations; however, it appears more sensitive in the early detection of pseudoaneurysms/abscesses. Furthermore, FDG-PET enables the detection of metastatic and primary extra-cardiac infections. Evidence for the additional value of 3D-TEE is scarce.As clinical implications are major, clinicians should have a low threshold to perform additional MDCT in acquired mechanical PHV obstruction. For suspected PHV endocarditis, both FDG-PET and MDCT have complementary value.

  15. Prevalence of Late Functional Tricuspid Regurgitation in Degenerative Mitral Regurgitation Surgery.

    PubMed

    Vaturi, Mordehay; Kotler, Tali; Shapira, Yaron; Weisenberg, Daniel; Monakier, Daniel; Sagie, Alexander

    2016-03-01

    Although significant late tricuspid regurgitation (TR) may develop after surgery for degenerative mitral regurgitation (MR), the use of routine tricuspid annuloplasty is debatable. The study aim was to determine the prevalence and predictors of significant late TR after surgery for degenerative MR. A total of 112 patients who had undergone surgery for degenerative MR without concomitant tricuspid valve repair (average follow up 7.7 ± 4.0 years) was studied retrospectively. The prevalence of post-surgical TR and predictors of progression were determined. The majority of patients (97%) had non-significant TR (less than moderate) prior to surgery, although an overall trend of progression towards significant TR (grades 2 or 3) was noted in 17 patients (p = 0.0006). Of the 18 patients (16%) with late postoperative significant TR, only nine (8%) had severe TR with only a single referral to surgery. New-onset post-surgical atrial fibrillation was more common in patients who developed late significant TR (p = 0.002). Multivariate analysis of the pre-surgery variables, age >65 years and left ventricular dysfunction were shown to be independent predictors of late functional TR. Significant progression in TR after surgery for degenerative MR was rare in this patient cohort. The impact of older age and left ventricular dysfunction at the time of surgery showed a strong association with post-surgical atrial fibrillation.

  16. Right ventricular remodeling and dysfunction with subsequent annular dilatation and tethering as a mechanism of isolated tricuspid regurgitation.

    PubMed

    Seo, Hye-Sun; Ha, Jong-Won; Moon, Jae Youn; Choi, Eui-Young; Rim, Se-Joong; Jang, Yangsoo; Chung, Namsik; Shim, Won-Heum; Cho, Seung-Yun; Kim, Sung Soon

    2008-10-01

    Secondary tricuspid regurgitation (TR) as a result of pulmonary hypertension and/or left-sided heart disease is caused by tricuspid valve (TV) annular dilatation and tethering of the tricuspid leaflet after right ventricular (RV) dilatation. However, the mechanism of isolated TR without significant pulmonary hypertension remains unknown. The present study investigated the RV function and TV deformations in patients with isolated TR to find out the mechanism and etiology of the disease. Twelve patients with isolated, severe TR were included. RV area, volume, ejection fraction (EF), tenting distance and tenting area were measured. These parameters were compared with 12 age-and gender-matched controls and 12 patients with secondary TR. The cause of isolated TR was incomplete coaptation associated with annular dilatation without other problems. Compared with the controls, RV end-diastolic volumes and annular diameters were significantly larger and RVEF was significantly lower in patients with isolated TR. Tenting area and tenting distance were also significantly higher. However, there were no significant differences in these parameters between patients with isolated and secondary TR. Isolated TR was associated with RV remodeling, systolic dysfunction and resultant annular dilatation and tethering of tricuspid leaflets.

  17. Recycling of the pulmonary valve: an elegant solution for secondary pulmonary regurgitation in patients with tetralogy of Fallot.

    PubMed

    Prêtre, René; Rosser, Barbara; Mueller, Christoph; Kretschmar, Oliver; Dave, Hitendu

    2012-09-01

    The purpose of this study was to review our experience with recycling of the pulmonary valve in cases of chronic pulmonary insufficiency after a transannular patch procedure as part of a repair of tetralogy of Fallot. Eight patients in whom the technique was used were reviewed. Technically, the valve was reapproximated at the anterior commissure if the valve leaflet was sufficiently developed and of good tissue quality. Additional corrections were performed in 5 patients (resection of an infundibular aneurysm [5 patients], repair of the tricuspid valve [1 patient]). The valve was competent with no or trivial regurgitation in 5 patients and a small regurgitation in 3 patients. There was no significant transvalvular gradient in 5 patients with tricuspid valves and a small gradient in 3 patients with a bicuspid valves (<23 mm Hg). The valve function remained stable over the follow-up period (median time, 32 months). Recycling of the pulmonary valve is an interesting concept that could avoid the necessary reoperations linked with valves or valved prostheses. The repair must be carefully followed in bicuspid valves because of a reduction in the opening area. Valve leaflets of good quality should be preserved during the primary repair of tetralogy of Fallot and the transannular incision should be made across the anterior commissure if possible. These steps should allow a few patients to profit from a recycling of their valves in the future. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Extracardiac conduit obstruction: initial experience in the use of Doppler echocardiography for noninvasive estimation of pressure gradient.

    PubMed

    Reeder, G S; Currie, P J; Fyfe, D A; Hagler, D J; Seward, J B; Tajik, A J

    1984-11-01

    Extracardiac valved conduits are often employed in the repair of certain complex congenital heart defects; late obstruction is a well recognized problem that usually requires catheterization for definitive diagnosis. A reliable noninvasive method for detecting conduit stenosis would be clinically useful in identifying the small proportion of patients who develop this problem. Continuous wave Doppler echocardiography has been used successfully to estimate cardiac valvular obstructive lesions noninvasively. Twenty-three patients with prior extracardiac conduit placement for complex congenital heart disease underwent echocardiographic and continuous wave Doppler echocardiographic examinations to determine the presence and severity of conduit stenosis. In 20 of the 23 patients, an adequate conduit flow velocity profile was obtained, and in 10 an abnormally increased conduit flow velocity was present. All but one patient had significant obstruction proven at surgery and in one patient, surgery was planned. In three patients, an adequate conduit flow velocity profile could not be obtained but obstruction was still suspected based on high velocity tricuspid regurgitant Doppler signals. In these three patients, subsequent surgery also proved that conduit stenosis was present. Doppler-predicted gradients and right ventricular pressures showed an overall good correlation (r = 0.90) with measurements at subsequent cardiac catheterization. Continuous wave Doppler echocardiography appears to be a useful noninvasive tool for the detection and semiquantitation of extracardiac conduit stenosis.

  19. Impact of the maze operation combined with left-sided valve surgery on the change in tricuspid regurgitation over time.

    PubMed

    Kim, Hyung-Kwan; Kim, Yong-Jin; Kim, Kwang-Il; Jo, Sang-Ho; Kim, Ki-Bong; Ahn, Hyuk; Sohn, Dae-Won; Oh, Byung-Hee; Lee, Myoung-Mook; Park, Young-Bae; Choi, Yun-Shik

    2005-08-30

    Atrial fibrillation (AF) has been reported to be a predisposing factor for the progression of TR in patients with previous mitral or combined mitral/aortic valve surgery. We hypothesized that the maze operation (MAZE) can prevent the progression of tricuspid regurgitation (TR) in these patients. We analyzed 170 patients (age, 45.5+/-10.9 years) who had undergone mitral or combined mitral/aortic valve surgery. On the basis of preoperative rhythm, patients were divided into 3 groups; GrI was composed of 44 patients with sinus rhythm, GrII of 48 who had undergone MAZE, and GrIII of 78 with AF who had not undergone MAZE. Echocardiographic examinations were performed before, immediately after, and 92.2+/-17.2 (range, 50 to 131) months after surgery. Preoperative and immediate postoperative clinical and echocardiographic parameters were similar among the groups. Insignificant TR at the immediate postoperative examination worsened with time in 7.3% of GrI (3 of 41), 12.8% of GrII (6 of 47), and 38.8% of GrIII (26 of 67) patients at the final examination (P=0.63 for GrI versus GrII, P=0.001 for GrI versus GrIII, P=0.005 for GrII versus GrIII). The incidence of significant TR at the final echocardiographic examination was higher in GrIII (39.7%) compared with GrI (9.1%) and GrII (14.6%) (P=0.001 for GrI versus GrIII, P=0.005 for GrII versus GrIII), whereas GrI and GrII did not show any difference (P=0.63). By multivariate analysis, the only factor identified to prevent TR progression was the group factor (GrI and GrII versus GrIII, P=0.002 and P=0.005, respectively). In a subgroup analysis of GrII according to the presence or absence of atrial mechanical activity, the absence of atrial mechanical activity was identified as an independent parameter for the progression of TR (P=0.001). AF predisposes patients undergoing mitral valve surgery to the progression of TR, which can be prevented by MAZE. This additional benefit of MAZE is largely dependent on the restoration and

  20. Surgical management of nasal obstruction.

    PubMed

    Moche, Jason A; Palmer, Orville

    2012-05-01

    The proper evaluation of the patient with nasal obstruction relies on a comprehensive history and physical examination. Once the site of obstruction is accurately identified, the patient may benefit from a trial of medical management. At times however, the definitive treatment of nasal obstruction relies on surgical management. Recognizing the nasal septum, nasal valve, and turbinates as possible sites of obstruction and addressing them accordingly can dramatically improve a patient's nasal breathing. Conservative resection of septal cartilage, submucous reduction of the inferior turbinate, and structural grafting of the nasal valve when appropriate will provide the optimal improvement in nasal airflow and allow for the most stable results. Copyright © 2012. Published by Elsevier Inc.

  1. Measurement of the ascending aorta diameter in patients with severe bicuspid and tricuspid aortic valve stenosis using dual-source computed tomography coronary angiography.

    PubMed

    Son, Jee Young; Ko, Sung Min; Choi, Jin Woo; Song, Meong Gun; Hwang, Hweung Kon; Lee, Sook Jin; Kang, Joon-Won

    2011-12-01

    We aimed to evaluate the diagnostic performance of dual-source computed tomography coronary angiography (DSCT-CA) in the measurement of the ascending aorta (AA) diameter and compare the AA diameter in patients with severe bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) stenosis. Eighty-eight consecutive patients (50 men, mean age 60.3 ± 13 year) with severe aortic stenosis (AS) underwent DSCT-CA before aortic valve surgery. Seventy-four of the 88 patients underwent cardiovascular magnetic resonance (CMR). The internal diameter of AA was measured from early-systole with DSCT-CA and CMR by 2 radiologists independently at 4 levels (aortic annulus, sinuses of Valsalva, sinotubular junction, and tubular portion at the right pulmonary artery). The patients were divided in to 2 groups (BAV [n = 53]; TAV [n = 35]) according to operative findings. Patients with BAV were significantly younger than those with TAV (P = 0.0035). Inter-observer agreement of AA diameters at 4 levels with DSCT-CA and CMR was excellent (intraclass correlation coefficient = 0.89-0.97). Also, the DSCT-CA and CMR measurements of the AA diameter strongly correlated (r = 0.871-0.976). Mean diameter of the AA by DSCT-CA was significantly larger in patients with BAV (34.4 ± 8.2 mm) as compared to those with TAV (30.6 ± 5.5 mm). The diameters at the sinuses of Valsalva, sinotubular junction, and tubular portion were significantly larger in BAV than in TAV. Twenty-two of 53 (41.5%) patients with BAV and 2 of 35 (5.7%) patients with TAV had AA dilatation > 45 mm. DSCT-CA allows accurate assessment of the AA diameters in patients with severe AS. Patients with severe BAV stenosis had larger AA diameters and higher prevalence of AA dilatation > 45 mm as compared to those with severe TAV stenosis.

  2. Left atrial isolation associated with mitral valve operations.

    PubMed

    Graffigna, A; Pagani, F; Minzioni, G; Salerno, J; Viganò, M

    1992-12-01

    Surgical isolation of the left atrium was performed for the treatment of chronic atrial fibrillation secondary to valvular disease in 100 patients who underwent mitral valve operations. From May 1989 to September 1991, 62 patients underwent mitral valve operations (group I); 19, mitral valve operations and DeVega tricuspid annuloplasty (group II); 15, mitral and aortic operations (group III); and 4, mitral and aortic operations and DeVega tricuspid annuloplasty (group IV). Left atrial isolation was performed, prolonging the usual left paraseptal atriotomy toward the left fibrous trigone anteriorly and the posteromedial commissure posteriorly. The incision was conducted a few millimeters apart from the mitral valve annulus, and cryolesions were placed at the edges to ensure complete electrophysiological isolation of the left atrium. Operative mortality accounted for 3 patients (3%). In 79 patients (81.4%) sinus rhythm recovered and persisted until discharge from the hospital. No differences were found between the groups (group I, 80.7%; group II, 68.5%; group III, 86.7%; group IV, 75%; p = not significant). Three late deaths (3.1%) were registered. Long-term results show persistence of sinus rhythm in 71% of group I, 61.2% of group II, 85.8% of group III, and 100% of group IV. The unique risk factor for late recurrence of atrial fibrillation was found to be preoperative atrial fibrillation longer than 6 months. Due to the satisfactory success rate in recovering sinus rhythm, we suggest performing left atrial isolation in patients with chronic atrial fibrillation undergoing valvular operations.

  3. Development of a Risk Prediction Model and Clinical Risk Score for Isolated Tricuspid Valve Surgery.

    PubMed

    LaPar, Damien J; Likosky, Donald S; Zhang, Min; Theurer, Patty; Fonner, C Edwin; Kern, John A; Bolling, Stephen F; Drake, Daniel H; Speir, Alan M; Rich, Jeffrey B; Kron, Irving L; Prager, Richard L; Ailawadi, Gorav

    2018-02-01

    While tricuspid valve (TV) operations remain associated with high mortality (∼8-10%), no robust prediction models exist to support clinical decision-making. We developed a preoperative clinical risk model with an easily calculable clinical risk score (CRS) to predict mortality and major morbidity after isolated TV surgery. Multi-state Society of Thoracic Surgeons database records were evaluated for 2,050 isolated TV repair and replacement operations for any etiology performed at 50 hospitals (2002-2014). Parsimonious preoperative risk prediction models were developed using multi-level mixed effects regression to estimate mortality and composite major morbidity risk. Model results were utilized to establish a novel CRS for patients undergoing TV operations. Models were evaluated for discrimination and calibration. Operative mortality and composite major morbidity rates were 9% and 42%, respectively. Final regression models performed well (both P<0.001, AUC = 0.74 and 0.76) and included preoperative factors: age, gender, stroke, hemodialysis, ejection fraction, lung disease, NYHA class, reoperation and urgent or emergency status (all P<0.05). A simple CRS from 0-10+ was highly associated (P<0.001) with incremental increases in predicted mortality and major morbidity. Predicted mortality risk ranged from 2%-34% across CRS categories, while predicted major morbidity risk ranged from 13%-71%. Mortality and major morbidity after isolated TV surgery can be predicted using preoperative patient data from the STS Adult Cardiac Database. A simple clinical risk score predicts mortality and major morbidity after isolated TV surgery. This score may facilitate perioperative counseling and identification of suitable patients for TV surgery. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Failing stentless Bioprostheses in patients with carcinoid heart valve disease.

    PubMed

    Schaefer, Andreas; Sill, Bjoern; Schoenebeck, Jeannette; Schneeberger, Yvonne; Reichenspurner, Hermann; Gulbins, Helmut

    2015-03-27

    Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate. The authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome. All patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves. We do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.

  5. Thromboembolism in patients with pericardial valves in the absence of chronic anticoagulation: 12 years' experience.

    PubMed

    García-Bengoechea, J B; González-Juanatey, J R; Rubio, J; Durán, D; Sierra, J

    1991-01-01

    Between January 1977 and January 1989, 465 pericardial bioprostheses were implanted in 424 patients. The mean age of patients was 59.1 years (range 16-81 y.) At the time of surgery, 68% of the patients suffered from chronic atrial fibrillation. Mitral valve replacement was performed in 167 patients, aortic valve replacement in 216, multiple replacement in 40 (36 mitral and aortic, 3 mitral and tricuspid, and 1 mitral, aortic and tricuspid), and 1 pulmonary valve replacement. The different types of pericardial valve used were: Ionescu-Shiley 408, Mitral Medical 23, Bioflo 30, and Hancock 4. Hospital mortality was 10.1% with an attrition rate of 1.8 episodes per 100 patients/year. The 12-year actuarial survival rate was 65.1%. No patient underwent long-term anticoagulant treatment. The first 144 patients undergoing mitral and multiple valve replacements received temporary anticoagulation for the first 8 weeks after surgery. There was no valve thrombosis observed. Altogether 19 thromboembolic events (6 early and 13 late) were clinically documented. One patient died after an embolic event. The linearized rates of thromboembolism were 1.64 episodes per 100 patients/year for mitral and multiple valve replacements and 0.33 episodes per 100 patients/year for aortic valve replacement, with an overall rate of 1.0 episodes per 100 patients/year. Excluding early thromboembolism, the linearized rate was 1.02 episodes per 100 patients/year overall. The actuarial freedom from embolism was 92.4% overall, 88.2% for the mitral and multiple valve replacement group, and 97.6% for the aortic valve replacement group at a maximum follow-up of 12 years.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Malformation of the canine mitral valve complex.

    PubMed

    Litu, S K; Tilley, L P

    1975-09-15

    Twenty-nine dogs, including 13 Great Danes and 5 German Shepherd Dogs and averaging 7.3 months age, were diagnosed clinically and radiographically as having mitral regurgitation. Alterations of the mitral valve complex included enlarged anulus; short thick leaflets, with an occasional cleft; short and stout or long and thin chordae tendineae; upward malposition of atrophic or hypertrophic papillary muscles; insertion of one papillary muscle directly into one or both leaflets; and diffuse endocardial fibrosis, occasionally with jet lesions in te left atrium. Other cardiac anomalies included dysplasia of the tricuspid valve (5 dogs), patent ductus afteriosus (2 dogs), aortic stenosis (2 dogs), and ventricular septal defect (1 dog).

  7. The Changing “Face” of Endocarditis in Kentucky: A Rise in Tricuspid Cases

    PubMed Central

    Seratnahaei, Arash; Leung, Steve W.; Charnigo, Richard J.; Cummings, Matthew S.; Sorrell, Vincent L.; Smith, Mikel D.

    2015-01-01

    Background Advancements in medical technology and increased life expectancy have been described as contributing to the evolution of endocarditis. We sought to determine whether there has been a change in the incidence, demographics, microbiology, complications, and outcomes of infective endocarditis over a ten-year time span. Methods We screened 28,420 transthoracic and transesophageal echocardiogram reports performed at our center for the following indications: fever, masses, emboli (including stroke), sepsis, bacteremia, and endocarditis in two time periods: 1999 through 2000 and 2009 through 2010. Data were collected from diagnosed endocarditis cases. Results Overall, 143 cases of infective endocarditis were analyzed (48 in 1999-2000 and 95 in 2009-2010). The endocarditis incidence per number of admissions remained nearly constant at 0.113% for 1999-2000 and 0.148% for 2009-2010 (p = 0.153). However, tricuspid valve involvement increased markedly from 6% to 36% (p < 0.001). Also, reported history of intravenous drug use increased from 15% to 40% (p = 0.002). Valvular complications doubled from 17% to 35% (p = 0.031). Septic pulmonary emboli increased from 10% to 25% (p = 0.047). Despite these noted differences, inpatient mortality remained unchanged at 25% and 28% (p = 0.696) for the two time periods, respectively. Conclusions The incidence of endocarditis at our center has not changed and mortality remains high, but the “face of endocarditis” in Kentucky has evolved with an increased incidence of tricuspid valve involvement, valvular complications, and embolic events. PMID:24769025

  8. [Simultaneous interventions on the ascending portion, arch of the aorta and cardiac valves in patients with Marfan's syndrome].

    PubMed

    Belov, Iu V; Stepanenko, A B; Gens, A P; Charchian, E R; Savichev, D D

    2007-01-01

    Simultaneous surgical interventions on the aorta and valvular system of the heart were performed in four patients presenting with aortic dissections and aneurysms conditioned by Marfan's syndrome. The following reconstructive operations were carried out: 1) prosthetic repair of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries into the side of the prosthesis according to the Benthall - De Bono technique, annuloplasty of the tricuspid valve according to the De Vega technique, valvuloplasty of the mitral valve by the Alferi technique; 2) grafting of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries according to the Kabrol's technique, plasty of the tricuspid valve by the De Vega technique; 3) prosthetic repair of the aortic arch with distal wedge-like excision of the membrane of the dissection and directing the blood flow along the both channels, plasty of the mitral valve, plasty of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side of the graft according to the Benthall - De Bono technique; (4) plasty of the mitral valve with a disk graft through the fibrous ring of the aortic valve, prosthetic repair of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side according to the Benthall-De Bono technique.

  9. Balloon Valvuloplasty of Tricuspid Stenosis: A Retrospective Study of 5 Labrador Retriever Dogs.

    PubMed

    Lake-Bakaar, G A; Griffiths, L G; Kittleson, M D

    2017-03-01

    There are limited reports of severe tricuspid valve stenosis in dogs and limited data regarding treatment and outcome. To evaluate clinical signs, echocardiographic features, and outcome of balloon valvuloplasty (BV) in dogs with severe tricuspid valve stenosis (TVS) in which BV was attempted. Five client-owned dogs with severe TVS. Records were retrospectively reviewed and data collected regarding signalment, clinical signs, diagnostic findings, procedures, and outcome. All dogs were Labrador Retrievers. Presenting complaints included episodic weakness/syncope (4/5), abdominal distension (4/5), lethargy (2/5), and exercise intolerance (2/5). The median and range of measurements before BV were as follows: TV mean velocity 1.5 m/s (range 1.4-1.7 m/s); velocity-time integral (VTI) 79.8 cm (42.4-99.1 cm); and TV maximum velocity 2.9 m/s (2.3-3.2 m/s). Measurements (available for 3 of 5 dogs) after BV were as follows: TV mean velocity 1.15 m/s (0.9-1.4 m/s); VTI 44.95 cm (41.4-54.8 cm); and TV maximum velocity 1.15 m/s (1.9-2.3 m/s). The procedure was attempted in all dogs and completed in 4/5 dogs. The largest balloon diameter ranged from 15 mm to 25 mm, and length ranged from 4 cm to 5 cm. Right atrial pressure decreased in 4/5 dogs. All but 1 dog had clinical improvement after BV, but recurrence of clinical signs occurred (2/5). Tricuspid regurgitation worsened in 1 dog culminating in right heart failure and euthanasia. BV can be an effective treatment; however, clinical signs can recur. Right heart failure due to worsened TR is a potential complication in dogs with pre-existing moderate-to-severe TR. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  10. Transcatheter valve-in-valve therapy using 6 different devices in 4 anatomic positions: Clinical outcomes and technical considerations.

    PubMed

    Conradi, Lenard; Silaschi, Miriam; Seiffert, Moritz; Lubos, Edith; Blankenberg, Stefan; Reichenspurner, Hermann; Schaefer, Ulrich; Treede, Hendrik

    2015-12-01

    Transcatheter valve-in-valve implantation (ViV) is emerging as a novel treatment option for patients with deteriorated bioprostheses. We report our cumulative experience using 6 types of transcatheter heart valves (THVs) in all anatomic positions. Seventy-five consecutive patients (74.1 ± 12.9 years, 50.7% male (38/75), logEuroSCORE I 26.2% ± 17.8%, STS-PROM 8.8% ± 7.4%) receiving ViV procedures from 2008 to 2014 were included for analysis. Data were prospectively gathered and retrospectively analyzed. ViV was performed in aortic (72.0%, 54/75), mitral (22.7%, 17/75), tricuspid (2.7%, 2/75), and pulmonary (2.7%, 2/75) positions. THVs used were Edwards SAPIEN (XT)/SAPIEN3 (52.0%, 39/75), Medtronic Core Valve/Core Valve Evolut(R) (34.7%, 26/75), St Jude Portico (4.0%, 3/75), Boston Scientific Lotus (4.0%, 3/75), Jena Valve (2.7%, 2/75), and Medtronic Engager (2.7%, 2/75). Interval from index procedure to ViV was 9.3 ± 4.9 years. Access was transapical in 53.3% (40/75), transfemoral (transarterial or transvenous) in 42.7% (32/75), transaortic in 2.7% (2/75), and transjugular in 1.3% (1/75). ViV was successful in 97.3% (73/75) with 2 patients requiring sequential THV implantation for initial malpositioning. Overall immediate procedural (≤72 hours) and all-cause 30-day mortality were 2.7% (2/75) and 8.0% (6/75). Corresponding values after aortic ViV were 1.9% (1/54) and 5.6% (3/54). No periprocedural strokes or cases of coronary obstruction occurred. Paravalvular leakage was less than or equal to mild in all cases. After aortic ViV, gradients were max/mean 34.1 ± 14.2/20.1 ± 7.1 mm Hg and effective orifice area (EOA) was 1.5 ± 1.4 cm(2). Corresponding values after mitral ViV were gradients max/mean 14.2 ± 8.2/4.7 ± 3.1 mm Hg and EOA 2.4 ± 0.9 cm(2). ViV can be performed in all anatomic positions with acceptable hemodynamic and clinical outcome in high-risk patients. Increasing importance of ViV can be anticipated considering growing use of surgical

  11. Recovery of atrial function after atrial compartment operation for chronic atrial fibrillation in mitral valve disease.

    PubMed

    Shyu, K G; Cheng, J J; Chen, J J; Lin, J L; Lin, F Y; Tseng, Y Z; Kuan, P; Lien, W P

    1994-08-01

    We prospectively studied the recovery of atrial function after atrial compartment operation and mitral valve surgery in patients with chronic atrial fibrillation caused by mitral valve disease. Chronic atrial fibrillation is the most common arrhythmia in mitral valve disease. This arrhythmia is associated with excessive morbidity and mortality. Mitral valve surgery alone rarely eliminates it. Twenty-two patients underwent mitral valve surgery and a new surgical method, atrial compartment operation. Doppler echocardiography was performed in all patients before operation and at 1 week and 2 and 6 months after operation in the successful cardioversion group. Peak early diastolic (E) and atrial (A) filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves were measured. Sinus rhythm was restored immediately after operation in 91% of patients and was maintained for > 1 week in 15 (68%) of 22 patients and > 6 months in 14 (64%) of 22. Eleven of 15 patients had left atrial paralysis (A/E integral ratio 0) at 1 week and 6 of 14 patients at 2 months. Nine of 15 patients had right atrial paralysis (A/E integral ratio 0) at 1 week and 1 of 14 patients at 2 months. Both left and right atrial contractile function (presence of an A wave on Doppler findings) was detected at 6 months in 14 patients. Mean (+/- SD) peak atrial filling velocity of the mitral valve was 15 +/- 26 cm/s at 1 week, 38 +/- 39 cm/s at 2 months and 93 +/- 32 cm/s at 6 months (p < 0.001). Mean peak atrial filling velocity of the tricuspid valve was 14 +/- 19 cm/s at 1 week, 33 +/- 19 cm/s at 2 months and 50 +/- 19 cm/s at 6 months (p < 0.001). Peak early diastolic and atrial filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves increased significantly from 1 week to 6 months. Chronic atrial fibrillation in mitral valve disease can often be eliminated by atrial compartment operation. No surgical mortality or significant

  12. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    PubMed

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p < 0.01). Patient-specific, 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  13. Mitochondrial apoptotic pathway activation in the atria of heart failure patients due to mitral and tricuspid regurgitation.

    PubMed

    Chang, Jen-Ping; Chen, Mien-Cheng; Liu, Wen-Hao; Lin, Yu-Sheng; Huang, Yao-Kuang; Pan, Kuo-Li; Ho, Wan-Chun; Fang, Chih-Yuan; Chen, Chien-Jen; Chen, Huang-Chung

    2015-08-01

    Apoptosis occurs in atrial cardiomyocytes in mitral and tricuspid valve disease. The purpose of this study was to examine the respective roles of the mitochondrial and tumor necrosis factor-α receptor associated death domain (TRADD)-mediated death receptor pathways for apoptosis in the atrial cardiomyocytes of heart failure patients due to severe mitral and moderate-to-severe tricuspid regurgitation. This study comprised eighteen patients (7 patients with persistent atrial fibrillation and 11 in sinus rhythm). Atrial appendage tissues were obtained during surgery. Three purchased normal human left atrial tissues served as normal controls. Moderately-to-severely myolytic cardiomyocytes comprised 59.7±22.1% of the cardiomyocytes in the right atria and 52.4±12.9% of the cardiomyocytes in the left atria of mitral and tricuspid regurgitation patients with atrial fibrillation group and comprised 58.4±24.8% of the cardiomyocytes in the right atria of mitral and tricuspid regurgitation patients with sinus rhythm. In contrast, no myolysis was observed in the normal human adult left atrial tissue samples. Immunohistochemical analysis showed expression of cleaved caspase-9, an effector of the mitochondrial pathways, in the majority of right atrial cardiomyocytes (87.3±10.0%) of mitral and tricuspid regurgitation patients with sinus rhythm, and right atrial cardiomyocytes (90.6±31.4%) and left atrial cardiomyocytes (70.7±22.0%) of mitral and tricuspid regurgitation patients with atrial fibrillation. In contrast, only 5.7% of cardiomyocytes of the normal left atrial tissues showed strongly positive expression of cleaved caspase-9. Of note, none of the atrial cardiomyocytes in right atrial tissue in sinus rhythm and in the fibrillating right and left atria of mitral and tricuspid regurgitation patients, and in the normal human adult left atrial tissue samples showed cleaved caspase-8 expression, which is a downstream effector of TRADD of the death receptor pathway

  14. Valve-in-valve using an Edwards Sapien XT into a JenaValve in a patient with a low originating left coronary artery and a heavily calcified aorta.

    PubMed

    Fujita, Buntaro; Scholtz, Smita; Ensminger, Stephan

    2016-04-01

    Coronary obstruction during transcatheter aortic valve implantation is a potentially life-threatening complication. Most of the widely used transcatheter heart valves require a certain distance between the basal aortic annular plane and the origins of the coronary arteries. We report the case of a successful valve-in-valve procedure with an Edwards SAPIEN XT valve into a JenaValve as a bail-out procedure in a patient with a low originating left coronary artery and a heavily calcified aorta. © 2015 Wiley Periodicals, Inc.

  15. Leaflet Area as a Determinant of Tricuspid Regurgitation Severity in Patients with Pulmonary Hypertension

    PubMed Central

    Afilalo, Jonathan; Grapsa, Julia; Nihoyannopoulos, Petros; Beaudoin, Jonathan; Gibbs, J. Simon R.; Channick, Richard N.; Langleben, David; Rudski, Lawrence G.; Hua, Lanqi; Handschumacher, Mark D.; Picard, Michael H.; Levine, Robert A.

    2015-01-01

    Background Tricuspid regurgitation (TR) is a risk factor for mortality in pulmonary hypertension (PH). TR severity varies among patients with comparable degrees of PH and right ventricular (RV) remodeling. The contribution of leaflet adaptation to the pathophysiology of TR has yet to be examined. We hypothesized that tricuspid leaflet area (TLA) is increased in PH, and that its size relative to RV remodeling determines TR severity. Methods and Results A prospective cohort of 255 patients with PH from pre- and post-capillary etiologies was assembled from two centers. Patients underwent a 3-D echocardiogram focused on the tricuspid apparatus. TLA was measured with the Omni custom software package. Compared with normal controls, PH patients had a twofold increase in RV volumes, 62% increase in annulus area, and 49% increase in TLA. Those with severe TR demonstrated inadequate increase in TLA relative to the closure area, such that the ratio of TLA-to-closure area <1.78 was highly predictive of severe TR (odds ratio 68.7; 95% CI 16.2, 292.7). The median vena contracta width was 8.5 mm in the group with small TLA and large closure area as opposed to 4.8 mm in the group with large TLA and large closure area. Conclusions TLA plays a significant role in determining which patients with PH develop severe functional TR. The ratio of TLA-to-closure area, reflecting the balance between leaflet adaptation vs. annular dilation and tethering forces, is an indicator of TR severity that may identify which patients stand to benefit from leaflet augmentation during tricuspid valve repair. PMID:25977303

  16. Leaflet area as a determinant of tricuspid regurgitation severity in patients with pulmonary hypertension.

    PubMed

    Afilalo, Jonathan; Grapsa, Julia; Nihoyannopoulos, Petros; Beaudoin, Jonathan; Gibbs, J Simon R; Channick, Richard N; Langleben, David; Rudski, Lawrence G; Hua, Lanqi; Handschumacher, Mark D; Picard, Michael H; Levine, Robert A

    2015-05-01

    Tricuspid regurgitation (TR) is a risk factor for mortality in pulmonary hypertension (PH). TR severity varies among patients with comparable degrees of PH and right ventricular remodeling. The contribution of leaflet adaptation to the pathophysiology of TR has yet to be examined. We hypothesized that tricuspid leaflet area (TLA) is increased in PH, and that the adequacy of this increase relative to right ventricular remodeling determines TR severity. A prospective cohort of 255 patients with PH from pre and postcapillary pathogeneses was assembled from 2 centers. Patients underwent a 3-dimensional echocardiogram focused on the tricuspid apparatus. TLA was measured with the Omni 4D software package. Compared with normal controls, patients with PH had a 2-fold increase in right ventricular volumes, 62% increase in annular area, and 49% increase in TLA. Those with severe TR demonstrated inadequate increase in TLA relative to the closure area, such that the ratio of TLA:closure area <1.78 was highly predictive of severe TR (odds ratio, 68.7; 95% confidence interval, 16.2-292.7). The median vena contracta width was 8.5 mm in the group with small TLA and large closure area as opposed to 4.8 mm in the group with large TLA and large closure area. TLA plays a significant role in determining which patients with PH develop severe functional TR. The ratio of TLA:closure area, reflecting the balance between leaflet adaptation versus annular dilation and tethering forces, is an indicator of TR severity that may identify which patients stand to benefit from leaflet augmentation during tricuspid valve repair. © 2015 American Heart Association, Inc.

  17. Severe tricuspid regurgitation in the aged: atrial remodeling associated with long-standing atrial fibrillation.

    PubMed

    Yamasaki, Naohito; Kondo, Fumiaki; Kubo, Toru; Okawa, Makoto; Matsumura, Yoshihisa; Kitaoka, Hiroaki; Yabe, Toshikazu; Furuno, Takashi; Doi, Yoshinori

    2006-12-01

    Severe idiopathic tricuspid regurgitation (TR) occurs in the aged, but the mechanism of TR is unclear and there is little information on atrial abnormalities associated with this condition. This study retrospectively analyzed patients with severe functional TR presenting with common clinical features suggesting a distinct syndrome. Eleven patients with severe functional TR were identified by reviewing the records of 16,235 consecutive patients. All patients had undergone clinical evaluation including echocardiography, electrocardiography and laboratory data. The median age of patients with severe functional TR was 78 years. All had a long-standing history of atrial fibrillation (median duration, 23 years). Clinical features are characterized by severe functional TR due to annular dilation, markedly dilated right atrium, episodes of right-sided heart failure, absent or diminished fibrillation waves on electrocardiogram, bradycardia probably due to partial atrial standstill, and decreased atrial natriuretic peptide secretion. During long-term follow up, right atrial size progressively increased in association with worsening TR. Severe functional TR occurs with long-standing atrial fibrillation and causes right-sided heart failure. The TR is caused by tricuspid valve systolic coaptation loss due to tricuspid annular dilation associated with atrial dilation. This condition is associated with atrial abnormalities, such as atrial standstill and impaired atrial natriuretic peptide secretion. We propose that atrial remodeling associated with atrial fibrillation is central to the occurrence of the syndrome.

  18. Anterior urethral valve associated with posterior urethral valves: report of 2 cases and review of the literature.

    PubMed

    Tran, Christine N; Reichard, Chad A; McMahon, Daniel; Rhee, Audrey

    2014-08-01

    Anterior urethral valve (AUV) associated with posterior urethral valves (PUVs) is an extremely rare congenital urologic anomaly resulting in lower urinary tract obstruction. We present our experience with 2 children with concomitant AUV and PUV as well as a literature review. The clinical presentation of concomitant AUV and PUV is variable. Successful endoscopic management can result in improvement in renal function, reversal of obstructive changes, and improvement or resolution of voiding dysfunction. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement

    NASA Technical Reports Server (NTRS)

    Sitges, M.; Kapadia, S.; Rubin, D. N.; Thomas, J. D.; Tuzcu, M. E.; Lever, H. M.

    2001-01-01

    When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.

  20. A 3D velocimetry study of the flow through prosthetic heart valves

    NASA Astrophysics Data System (ADS)

    Ledesma, R.; Zenit, R.; Pulos, G.; Sanchez, E.; Juarez, A.

    2006-11-01

    Blood damage commonly appears in medical valve prothesis. It is a mayor concern for the designers and surgeons. It is well known that this damage and other complications result from the modified fluid dynamics through the replacement valve. To evaluate the performance of prosthetic heart valves, it is necessary to study the flow through them. To conduct this study , we have built a flow channel that emulates cardiac conditions and allows optical access such that a 3D-PIV velocimetry system could be used. The experiments are aimed to reconstruct the downstream structure of the flow through a mechanical and a bio-material tricuspid heart valve prothesis. Preliminary results show that the observed coherent structures can be related with haemolysis and trombosis, illnesses commonly found in valve prothesis recipients. The mean flow, the levels of strain rate and the turbulence intensity generated by the valves can also be directly related to blood damage. In general, bio-material made valves tend to reduce these complications.

  1. Tricuspid Clip: Step-by-Step and Clinical Data.

    PubMed

    Tang, Gilbert H L

    2018-01-01

    Symptomatic severe tricuspid regurgitation (TR), if untreated, carries a dismal prognosis. These patients are at very high risk for surgical repair or replacement and transcatheter options to treat TR are emerging. More than 300 transcatheter tricuspid repairs with the MitraClip system have been performed worldwide with promising results. The TriClip system, with the MitraClip NT delivered via a dedicated tricuspid steerable guide catheter, is currently under investigation. This article describes the step-by-step technique on using the MitraClip system to perform transcatheter tricuspid repair using echocardiographic and fluoroscopic guidance. The latest data on worldwide experience with tricuspid clipping are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. [Transcatheter aortic valve replacement].

    PubMed

    Sawa, Yoshiki

    2014-07-01

    While transcatheter aortic valve replacement( TAVR) has spread rapidly all over the world for highrisk patients with severe aortic stenosis (AS), SAPIEN XT was approved in Japan in October 2013. Since that, approximately 400 TAVR cases were performed in Japan. In our institute, we have performed 164 cases since first case in Japan in 2009 and have achieved satisfactory early results(30-day mortality:1.2%). At the same time, however, simultaneously various TAVR-related complications including a paravalvular leak, stroke, vascular complications, and coronary obstruction were observed. A reduction in the incidence and severity of these complications had led technical improvements in various new devices(2nd generation TAVR device such as the SAPIEN 3, ACURATE, and JenaValve) and in implantation techniques including repositioning/recapturing features, paravalvular sealing technologies, and prevention of coronary obstruction. Furthermore, there is also increasing experience with special indications for TAVR such as pure aortic valve insufficiency or valve-in-valve techniques. Currently, an increasing number of publications of midterm results demonstrate good prosthetic valve function and durability, with good quality of life and low morbidity after TAVR. There are also some randomized trials such as PARTNER 2 or SURTAVI to investigate potential benefits of TAVR for intermediate-risk patients. These improvements in the TAVR devices promises the expansion of TAVR towards the treatment of lower-risk patients in the near future.

  3. Congenital absence of pulmonary valve leaflets.

    PubMed Central

    Buendia, A; Attie, F; Ovseyevitz, J; Zghaib, A; Zamora, C; Zavaleta, D; Vargas-Barron, J; Richheimer, R

    1983-01-01

    Congenital absence of pulmonary valve leaflets is an uncommon condition usually associated with ventricular septal defect and an obstructive pulmonary valve ring. Twenty-one patients with these malformations are described. Twenty had an associated ventricular septal defect with ventriculoarterial concordance, and one also had transposition of the great arteries, ventricular septal defect, and obstructive pulmonary valve ring. The clinical features, cardiac catheterisation findings, and angiocardiographic results are presented. Twelve patients underwent cardiac surgery. Three patients died, one in the early, and the other two in the late postoperative period. The results, according to the surgical technique employed and postoperative cardiac catheterisation findings, showed that patients in whom the bioprostheses were implanted in the pulmonary position had a better late follow-up. Images PMID:6860509

  4. [Traumatic tricuspid insufficiency. Apropos of 2 cases].

    PubMed

    Ventre, F; Bertinchant, J P; Noblet, D; Frapier, J M; Carabasse, D; Nigond, J; Ledermann, B; Cohen, S; Joubert, P; Grolleau-Raoux, R

    1995-06-01

    The authors report two cases of tricuspid regurgitation by a ruptured anterior papillary muscle secondary to non-penetrating thoracic trauma. In the presence of suggestive clinical and electrocardiographic abnormalities (systolic murmur, right heart failure, right bundle branch block), echocardiography confirmed the tricuspid regurgitation, showed its mechanism and excluded any other intracardiac lesions. Tricuspid annuloplasty was performed in both cases because of the persistence of failure or degradation of the patient's clinical condition. Peroperative echocardiography was used to judge the quality of the surgical repair in both cases. Traumatic tricuspid regurgitation is a rare condition and the diagnosis is often delayed. Echocardiography is the investigation of choice and guides treatment which is essentially valvular repair in symptomatic patients.

  5. Non-obstructive prosthetic aortic valve thrombosis presenting with acute myocardial infarction and stroke in a patient with inadequate low-molecular-weight heparin treatment. The unlucky patient and the (pseudo)prudent physician.

    PubMed

    Paci, Anna Maria; Lattanzi, Fabio; Cabani, Enrico; Conti, Umberto; De Tommasi, Salvatore Mario

    2007-04-01

    Non-obstructive prosthetic valve thrombosis is a rare and underestimated complication in patients with left-sided mechanical heart valves. Systemic embolisation, mainly involving the cerebral circulation, often represents the first clinical manifestation. We report a case of multiple, successive embolizations in the coronary and cerebral circulation, presenting with an acute myocardial infarction and stroke in a patient with latent, non-obstructive thrombosis of a mechanical bileaflet aortic valve. Because of scheduled urological surgery, chronic vitamin K antagonist treatment had previously been discontinued and replaced with low-molecular-weight heparin, at inadequate dosage. Following coronary arteriography, brain computed tomography scan and transoesophageal echocardiography, thrombolysis was performed successfully. This case emphasises the utility of performing transoesophageal echocardiography routinely in the presence of ischaemic signs in patients with mechanical heart valves. In patients requiring discontinuation of oral anticoagulant therapy, accurate management and continuous monitoring of alternative medications are needed in order to avoid severe thromboembolic complications.

  6. Flexible band versus rigid ring annuloplasty for functional tricuspid regurgitation: two different patterns of right heart reverse remodelling

    PubMed Central

    Gatti, Giuseppe; Dell'Angela, Luca; Morosin, Marco; Maschietto, Luca; Pinamonti, Bruno; Benussi, Bernardo; Forti, Gabriella; Nicolosi, Gian Luigi; Sinagra, Gianfranco; Pappalardo, Aniello

    2016-01-01

    OBJECTIVES Annuloplasty bands and rings are widely used to treat functional tricuspid regurgitation (TR). However, the question as to which is the ideal annuloplasty device remains open. Early and late outcomes of tricuspid valve annuloplasty with flexible band (B-TVA) or rigid ring (R-TVA) are compared in the present study. METHODS Between 1999 and 2014, 462 consecutive patients (mean age, 69.2 ± 9.5 years) with grade ≥1+ functional TR (graded from 0 to 3+) underwent either B-TVA (n = 345; mean EuroSCORE II 9.2 ± 10.8%) or R-TVA (n = 117; mean EuroSCORE II 12 ± 13.4%) in addition to other cardiac procedures at the authors' institution. RESULTS One-to-one propensity score-matched analysis resulted in 98 pairs with similar baseline characteristics and operative risk. Hospital mortality was 7.5% after B-TVA and 12% after R-TVA (P = 0.14). R-TVA was associated with higher rates of low cardiac output (10.1 vs 17.9%, P = 0.025) and transient complete atrioventricular block (10.3 vs 17.2%, P = 0.046). Among the matched pairs, there were no significant differences in hospital mortality (5.1 vs 9.2%, P = 0.27) and perioperative complications. Both in overall series and matched pairs, between B-TVA and R-TVA patients, there were no significant differences in freedom from all-cause death (P = 0.29 and 0.91), cardiac and cerebrovascular deaths (P = 0.63 and 0.87) and grade ≥2+ TR (P = 0.68 and 0.77). Right atrial and tricuspid valve reverse remodelling combined with right ventricular reverse remodelling occurred after R-TVA but not after B-TVA. CONCLUSIONS B-TVA and R-TVA are equally effective in the treatment of functional TR. However, R-TVA causes over time a more complete right heart reverse remodelling. PMID:26993479

  7. Functional tricuspid regurgitation and the right ventricle: What we do not know is more than we know.

    PubMed

    Calafiore, Antonio Maria; Bartoloni, Giovanni; Al Amri, Hussein; Iacò, Angela Lorena; Abukhudair, Walid; Lanzaro, Bianca Iadanza; Di Mauro, Michele

    2012-11-01

    The tricuspid valve (TV) lies in between the right atrium and the right ventricle (RV), consisting of annulus, leaflets, chords and papillary muscles. The RV appears triangular-shaped in a lateral view and crescent-shaped in a cross-section one. In normal conditions, the septum is concave toward the left ventricle (LV) in both systole and diastole and the RV volume is larger than the LV volume, although its mass is a third of the LV. The strict relationship between the TV apparatus and the RV underlies the physiological mechanism of TV functioning, and so, the RV plays an important role in case of functional tricuspid regurgitation. Nevertheless, the systematic assessment of RV is still not performed mainly due to lack of standardization. Hence, new echocardiographic guidelines have recently been proposed to standardize the RV assessment using transthoracic 2D‑echocardiography. 3D-echocardiography and MRI are more useful to measure volumes and ejection fraction; in particular, MRI is able to provide a tissue evaluation. Today, surgical strategies are directed mainly to the annulus with fluctuating results because functional tricuspid regurgitation is not due only to the annulus but also to the RV, which is difficult to assess, due to its evolution being unpredictable and complicated by the interaction with LV.

  8. Sequenced drive for rotary valves

    DOEpatents

    Mittell, Larry C.

    1981-01-01

    A sequenced drive for rotary valves which provides the benefits of applying rotary and linear motions to the movable sealing element of the valve. The sequenced drive provides a close approximation of linear motion while engaging or disengaging the movable element with the seat minimizing wear and damage due to scrubbing action. The rotary motion of the drive swings the movable element out of the flowpath thus eliminating obstruction to flow through the valve.

  9. Three-dimensional echocardiographic evaluation of an incidental quadricuspid aortic valve.

    PubMed

    Armen, Todd A; Vandse, Rashmi; Bickle, Katherine; Nathan, Nadia

    2008-03-01

    Quadricuspid aortic valve is one of the rare forms of congenital cardiac valvular disease. Its diagnosis is often missed, even with the transthoracic echocardiogram. Many of these patients progress to aortic incompetence later in life requiring surgical intervention. In addition, quadricuspid aortic valve can be associated with other congenital cardiac deformities. Hence early recognition and follow-up is critical in these patients. We report a patient with quadricuspid aortic valve identified on intraoperative transesophageal 3-D echocardiography. This 66-year-old male presented with the features of congestive heart failure. The preoperative transthoracic echocardiogram (TTE) disclosed, moderately severe aortic valve insufficiency along with severe mitral and tricuspid regurgitation, but failed to reveal the quadricuspid anomaly of the aortic valve. Interestingly, this patient had undergone transthoracic echocardiography on two previous occasions during the past seven years for the evaluation of his valvular heart disease, which all failed to document this anomaly. Intraoperatively, transesophageal echocardiography (TEE) displayed an aortic valve composed of three medium and one small cusps. Our patient's case demonstrates the usefulness of transesophageal echocardiography in detection of this uncommon congenital malformation.

  10. A rare situation in acute rheumatic carditis: Involvement of all four valves.

    PubMed

    Güvenç, Osman; Çimen, Derya

    2017-01-01

    Güvenç O, Çimen D. A rare situation in acute rheumatic carditis: Involvement of all four valves. Turk J Pediatr 2017; 59: 497-500. Acute rheumatic fever continues to be an important health problem, especially in countries that are socioeconomically underdeveloped. Carditis, which develops in approximately half of the patients, is responsible for both early-stage mortality as well as late-stage surgical treatment due to heart valve insufficiency or stenosis. The most frequent and severe valve involvement is with the mitral valve, while the aortic valve has the second highest incidence of involvement. Pulmonary and tricuspid valves are rarely involved. The literature cites a few adult cases in which all four valves are affected by rheumatic carditis; however, to the best of our knowledge, there have been no acute-stage rheumatic carditis pediatric cases reported. This article presents a 13-year-old male patient of Syrian origin who escaped to Turkey from the war in his country, and who was in the acute stage of rheumatic carditis in which all four valves were involved.

  11. Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial

    PubMed Central

    McElhinney, Doff B.; Hellenbrand, William E.; Zahn, Evan M.; Jones, Thomas K.; Cheatham, John P.; Lock, James E.; Vincent, Julie A.

    2014-01-01

    Background Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (≥1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8±4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5±2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. Conclusions In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870. PMID

  12. Feasibility of Valve-in-Valve Procedure for Degenerated St. Jude Medical Trifecta Bioprosthesis.

    PubMed

    Verhoye, Jean-philippe; Harmouche, Majid; Soulami, Reda Belhaj; Thebault, Christophe; Boulmier, Dominique; Leguerrier, Alain; Anselmi, Amedeo

    2015-07-01

    The valve-in-valve (ViV) procedure is an option for patients with symptomatic structural degeneration of a bioprosthesis and excessive reoperative risk. The risk of coronary obstruction appears to be increased if ViV is performed for certain pericardial prostheses in which the leaflets are mounted outside the stent posts. Herein is described a successful ViV for a degenerated Trifecta aortic bioprosthesis, and the technical considerations for performing a ViV procedure within such types of prosthesis are considered. Emphasis is placed on the importance of preoperative investigations (computed tomography scan-based measurements of coronary ostial height and of sinus of Valsalva diameters), and on the precise deployment of the valve (transapical approach with transesophageal echocardiography control) to minimize the risk of major complications. The presence of a failing Trifecta bioprosthesis should not be considered an absolute contraindication to ViV on the basis of the risk of coronary obstruction.

  13. The Leipzig experience with robotic valve surgery.

    PubMed

    Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W

    2000-01-01

    The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

  14. Technical pitfalls and tips for the valve-in-valve procedure

    PubMed Central

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has emerged as a viable treatment modality for patients with severe aortic valve stenosis and multiple co-morbidities. More recent indications include the use of transcatheter heart valves (THV) to treat degenerated bioprosthetic surgical heart valves (SHV), which are failing due to stenosis or regurgitation. Valve-in-valve (VIV) procedures in the aortic position have been performed with a variety of THV devices, although the balloon-expandable SAPIEN valve platform (Edwards Lifesciences Ltd, Irvine, CA, USA) and self-expandable CoreValve platform (Medtronic Inc., MN, USA) have been used in majority of the patients. VIV treatment is appealing as it is less invasive than conventional surgery but optimal patient selection is vital to avoid complications such as malposition, residual high gradients and coronary obstruction. To minimize the risk of complications, thorough procedural planning is critical. The first step is identification of the degenerated SHV, including its model, size, fluoroscopic appearance. Although label size and stent internal diameter (ID) are provided by the manufacturer, it is important to note the true ID. The true ID is the ID of a SHV after the leaflets are mounted and helps determine the optimal size of THV. The second step is to determine the type and size of the THV. Although this is determined in the majority of the cases by user preference, in certain situations one THV may be more suitable than another. As the procedure is performed under fluoroscopy, the third step is to become familiarized with the fluoroscopic appearance of both the SHV and THV. This helps to determine the landmarks for optimal positioning, which in turn determines the gradients and fixation. The fourth step is to assess the risk of coronary obstruction. This is performed with either aortic root angiography or ECG-gated computerised tomography (CT). Finally, the route of approach must be carefully planned. Once these

  15. Contribution of mitral valve leaflet length and septal wall thickness to outflow tract obstruction in patients with hypertrophic cardiomyopathy.

    PubMed

    Morant, Kareem; Mikami, Yoko; Nevis, Immaculate; McCarty, David; Stirrat, John; Scholl, David; Rajchl, Martin; Giannoccaro, Peter; Kolman, Louis; Heydari, Bobby; Lydell, Carmen; Howarth, Andrew; Grant, Andrew; White, James A

    2017-08-01

    We sought to examine whether elongation of the mitral valve leaflets in patients with hypertrophic cardiomyopathy (HCM) is synergistic to septal wall thickness (SWT) in the development of left ventricular outflow tract obstruction (LVOTO). HCM is a common genetic cardiac disease characterized by asymmetric septal hypertrophy and predisposition towards LVOTO. It has been reported that elongation of the mitral valve leaflets may be a primary phenotypic feature and contribute to LVOTO. However, the relative contribution of this finding versus SWT has not been studied. 152 patients (76 with HCM and 76 non-diseased age, race and BSA-matched controls) and 18 young, healthy volunteers were studied. SWT and the anterior mitral valve leaflet length (AMVLL) were measured using cine MRI. The combined contribution of these variables (SWT × AMVLL) was described as the Septal Anterior Leaflet Product (SALP). Peak LVOT pressure gradient was determined by Doppler interrogation and defined as "obstructive" if ≥ 30 mmHg. Patients with HCM were confirmed to have increased AMVLL compared with controls and volunteers (p < 0.01). Among HCM patients, both SWT and SALP were significantly higher in patients with LVOTO (N = 17) versus without. SALP showed modest improvement in predictive accuracy for LVOTO (AUC = 0.81) among the HCM population versus SWT alone (AUC = 0.77). However, in isolated patients this variable identified patients with LVOTO despite modest SWT. Elongation of the AMVLL is a primary phenotypic feature of HCM. While incremental contributions to LVOTO appear modest at a population level, specific patients may have dominant contribution to LVOTO. The combined marker of SALP allows for maintained identification of such patients despite modest increases in SWT.

  16. Aortic valve replacement using continuous suture technique in patients with aortic valve disease.

    PubMed

    Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku

    2013-08-01

    The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

  17. Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

    PubMed

    Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki

    2013-01-01

    This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; P<0.0001). MDCT can be used to clearly visualize subprosthetic pannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.

  18. The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement

    PubMed Central

    McElhinney, Doff B; Hennesen, Jill T

    2013-01-01

    The Melody® transcatheter pulmonary valve (TPV) is a percutaneous valve system designed for the treatment of obstruction and/or regurgitation of prosthetic conduits placed between the right ventricle and pulmonary arteries in patients with congenital heart disease. In 2000, Melody TPV became the first transcatheter valve implanted in a human; in 2006 it became the first transcatheter valve commercially available anywhere in the world; and in 2010 it was launched as the first commercially available transcatheter valve in the United States. In this review, we present the clinical background against which the Melody valve was developed and implemented, introduce the rationale for and challenges of transcatheter valve technology for this population, outline the history and technical details of its development and use, and summarize currently available data concerning the performance of the device. PMID:23834411

  19. La plastie tricuspide: annuloplastie de Carpentier versus technique de De VEGA

    PubMed Central

    Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir

    2017-01-01

    L'atteinte de la valve tricuspide a été longtemps négligée aussi bien par cardiologue que par le chirurgien, mais depuis quelques années, la fuite tricuspidienne a été démontrée comme un facteur pronostic dans l'évolution des patients opérés d'une valvulopathie du c'ur gauche. Plusieurs techniques de plastie tricuspide ont été développées et les études publiées divergent sur les résultats de ces techniques; Nous avons mené ce travail afin d'évaluer les résultats de plastie tricuspide dans une population caractérisée par une forte prévalence de la maladie rhumatismale et de comparer les techniques d'annuloplastie de carpentier versus la plastie de DeVEGA. Etude rétrospective menée sur une période de 25 ans ayant inclus les patients traités par plastie tricuspide dans le service de cardiologie de SFAX. Nous avons comparé les résultats de groupe 1 (annuloplastie de Carpentier) vs groupe 2 (plastie de DeVEGA) 91 patients étaient inclus dans notre étude, avec 45 patients dans le groupe 1et 46 patients dans le groupe 2. La plupart des patients avaient une IT moyenne ou importante (83%) avant la chirurgie, une dilatation de l'anneau a été observée chez 90% des patients sans qu'il y ait une différence significatives entre le groupe 1 et 2. Les résultats immédiats étaient comparables entre les deux techniques mais au cours de suivi une insuffisance récurrente au moins moyenne a été plus significativement fréquente dans le groupe de plastie de DeVEGA. Les facteurs prédictifs d'IT récurrente significative au long cours étaient en étude multivariée la technique de DeVEGA (OR=3.26 (1.12-9.28)) et la pression artérielle pulmonaire systolique préoperatoire (OR=1.06 (1.01-1.12)). La plastie tricuspide avec anneau de Carpentier semble garantir de meilleurs résultats que la plastie de DeVEGA, par contre une PAPS préopératoire élevée est prédictive de récurrence de la fuite tricuspidienne même après plastie d'où l

  20. Mitral and tricuspid valve rupture after moderate blunt chest trauma.

    PubMed

    Bailey, P L; Peragallo, R; Karwande, S V; Lapunzina, P

    2000-02-01

    We present a patient with rupture of both atrioventricular valves in a previously healthy adult man who sustained a 5-foot fall. The mechanism of injury was such that it would not necessarily raise an adequate index of suspicion for valvular damage had valvular rupture not occurred. The usefulness of perioperative echocardiography is highlighted.

  1. Transient severe tricuspid regurgitation after transplantation of an extremely oversized donor heart in a child-Does size matter? A case report.

    PubMed

    Birnbaum, J; Ulrich, S M; Schramm, R; Hagl, C; Lehner, A; Fischer, M; Haas, N A; Heineking, B

    2017-02-01

    In pediatric heart transplantation, the size of the donor organ is an important criterion for organ allocation. Oversized donor hearts are often accepted with good results, but some complications in relation to a high donor-recipient ratio have been described. Our patient was transplanted for progressive heart failure in dilated cardiomyopathy. The donor-to-recipient weight ratio was 3 (donor weight 65 kg, recipient weight 22 kg). The intra-operative echocardiography before chest closure showed excellent cardiac function, no tricuspid valve regurgitation, and a normal central venous pressure. After chest closure, central venous pressure increased substantially and echocardiography revealed a severe tricuspid insufficiency. As other reasons for right ventricular dysfunction, that is, myocardial ischemia, pulmonary hypertension, and rejection, were excluded, we assumed that the insufficiency was caused by an alteration of the right ventricular geometry. After 1 week, the valve insufficiency regressed to a minimal degree. In pediatric heart transplant patients with a high donor-to-recipient weight ratio, the outlined complication may occur. If other reasons for right ventricular heart failure can be ruled out, this entity is most likely caused by an acute and transient alteration of the right ventricular geometry that may disappear over time. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Programmable valve shunts: are they really better?

    PubMed

    Kataria, Rashim; Kumar, Vimal; Mehta, Veer Singh

    2012-01-01

    Programmable valve shunts allows selection of opening pressure of shunt valve. In the presented article, a unique complication pertaining to programmable shunts has been discussed. A 5-year-old boy who had tectal plate low grade glioma with obstructive hydrocephalus was managed with Codman programmable ventriculoperitoneal shunt. There was a spontaneous change in the opening pressure of the shunt valve leading to shunt malfunction. Routinely used household appliances produce a magnetic field strong enough to cause change in the setting of shunt valve pressure and may lead to valve malfunction. Other causes of programmable valve malfunction also discussed.

  3. Continuous Flow Left Ventricular Assist Device Implant Significantly Improves Pulmonary Hypertension, Right Ventricular Contractility, and Tricuspid Valve Competence

    PubMed Central

    Atluri, Pavan; Fairman, Alexander S.; MacArthur, John W.; Goldstone, Andrew B.; Cohen, Jeffrey E.; Howard, Jessica L.; Zalewski, Christyna M.; Shudo, Yasuhiro; Woo, Y. Joseph

    2014-01-01

    Background Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. Methods One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. Results There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. Conclusion Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant. PMID:24118109

  4. Quantification and comparison of the mechanical properties of four human cardiac valves.

    PubMed

    Pham, Thuy; Sulejmani, Fatiesa; Shin, Erica; Wang, Di; Sun, Wei

    2017-05-01

    Although having the same ability to permit unidirectional flow within the heart, the four main valves-the mitral valve (MV), aortic (AV), tricuspid (TV) and pulmonary (PV) valves-experience different loading conditions; thus, they exhibit different structural integrity from one another. Most research on heart valve mechanics have been conducted mainly on MV and AV or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same aged patient population whose death was unrelated to cardiovascular disease. A total of 114 valve leaflet samples were excised from 12 human cadavers whose death was unrelated to cardiovascular disease (70.1±3.7years old). Tissue mechanical and structural properties were characterized by planar biaxial mechanical testing and histological methods. The experimental data were then fitted with a Fung-type constitutive model. The four valves differed substantially in thickness, degree of anisotropy, and stiffness. The leaflets of the left heart (the AV leaflets and the anterior mitral leaflets, AML) were significantly stiffer and less compliant than their counterparts in the right heart. TV leaflets were the most extensible and isotropic, while AML and AV leaflets were the least extensible and the most anisotropic. Age plays a significant role in the reduction of leaflet stiffness and extensibility with nearly straightened collagen fibers observed in the leaflet samples from elderly groups (65years and older). Results from 114 human leaflet samples not only provided a baseline quantification of the mechanical properties of aged human cardiac valves, but also offered a better understanding of the age-dependent differences among the four valves. It is hoped that the experimental data collected and the associated constitutive models in this study can facilitate future studies of valve diseases, treatments and the development of interventional devices. Most research on heart valve

  5. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    PubMed

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% <1 year); 86 (45%) had a preceding balloon valvuloplasty. The indications for the procedure were stenotic (n = 123; 64%), regurgitant (n = 63; 33%) or combined (n = 7; 4%) disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association

  6. Reversible tricuspid valve stenosis due to a metastatic dissemination of a noncardiac sarcoma.

    PubMed

    Uribe-Etxebarria, Naia; Voces, Roberto; Rodriguez, Miguel Angel; Llorente, Alberto; Perez, Pedro; Aramendi, Jose I

    2005-07-01

    Malignant disease is present in the pericardium of 1.5% to 20.6% of patients dying of malignant diseases as was examined postmortem. We present a case of a 57-year-old man with a history of Hodgkin's disease and a sarcoma of gluteus who presented with tachypnea, generalized weakness, and anasarca for 7 days. The echocardiogram revealed the presence of a significant pericardial thickening and localized pericardial effusion resulting from a tricuspid stenosis. A right anterior thoracotomy was performed, and a pericardiectomy (4 x 4 cm) was done. The histologic examination of the pericardium revealed the presence of a metastatic dissemination from a sarcoma. The cause for the clinical presentation and the treatment of malignant pericardial disease are discussed.

  7. Acquired discrete subaortic stenosis late after mitral valve replacement.

    PubMed

    Mohan, Jagdish C; Shukla, Madhu; Mohan, Vishwas; Sethi, Arvind

    2016-09-01

    Although acquired left ventricular outflow obstruction has been reported in a variety of conditions, there are scant reports of its occurrence following mitral valve replacement (MVR). This study describes two female patients, who developed severe discrete subaortic stenosis, five years following MVR. In both cases, the mitral valve was replaced by a porcine Carpentier-Edwards 27-mm bioprosthesis with preservation of mitral valve leaflets. The risk of very late left ventricular outflow tract obstruction after bio-prosthetic MVR with preservation of subvalvular apparatus needs to be kept in mind in symptomatic patients. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  8. Intracameral air injection during Ahmed glaucoma valve implantation in neovascular glaucoma for the prevention of tube obstruction with blood clot: Case Report.

    PubMed

    Hwang, Sung Ha; Yoo, Chungkwon; Kim, Yong Yeon; Lee, Dae Young; Nam, Dong Heun; Lee, Jong Yeon

    2017-12-01

    Glaucoma drainage implant surgery is a treatment option for the management of neovascular glaucoma. However, tube obstruction by blood clot after Ahmed glaucoma valve (AGV) implantation is an unpredictable clinically challenging situation. We report 4 cases using intracameral air injection for the prevention of the tube obstruction of AGV by blood clot. The first case was a 57-year-old female suffering from ocular pain because of a tube obstruction with blood clot after AGV implantation in neovascular glaucoma. Surgical blood clot removal was performed. However, intractable bleeding was noted during the removal of the blood clot, and so intracameral air injection was performed to prevent a recurrent tube obstruction. After the procedure, although blood clots formed around the tube, the tube opening where air could touch remained patent. In 3 cases of neovascular glaucoma with preoperative severe intraocular hemorrhages, intracameral air injection and AGV implantation were performed simultaneously. In all 3 cases, tube openings were patent. It appears that air impeded the blood clots formation in front of the tube opening. Intracameral air injection could be a feasible option to prevent tube obstruction of AGV implant with a blood clot in neovascular glaucoma with high risk of tube obstruction. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  9. Real-world echocardiography in patients referred for mitral valve surgery: the gap between guidelines and clinical practice.

    PubMed

    De Groot-de Laat, Lotte E; Ren, Ben; McGhie, Jackie; Oei, Frans B S; Raap, Goris Bol; Bogers, J J C; Geleijnse, Marcel L

    2014-11-01

    Mitral regurgitation (MR) is a common disorder for which mitral valve surgery is an established therapy. Although surgical indications are clearly defined for the management of valvular heart disease, a gap exists between current guidelines and their effective application. The study aim was to provide an insight into the diagnostic information provided for cardiac surgeons before performing mitral valve surgery. The source documents and echocardiographic studies of 100 patients, referred by nine hospitals, were screened for arguments for MR severity justifying referral for surgery. Details of the documented MR mechanism, mitral annulus (MA) size, tricuspid regurgitation (TR) severity and annulus size were also noted. According to the referring physician, MR was severe in 83% and moderate-to-severe in 17%. In the great majority of patients (98%) the MR mechanism was mentioned, although specific information on the prolapsing scallops was available in only 17% of cases. The recommended primary determinants of MR severity, vena contracta and proximal isovelocity surface area (PISA) were measured in only 22% and 31% of patients, respectively. In 94% of patients with available PISA information this was described only qualitatively. Correct image expansion using the zoom mode was performed in only 25% of these patients, and a correct adaptation of the Nyquist limit in only 6%. Tricuspid annulus measurements guiding the need for concomitant tricuspid valvuloplasty in patients with less than severe TR were reported in only 6% of patients. These data demonstrate a clear and important gap between current guidelines and real-world practice with regards to the echocardiographic diagnostic information provided to the surgeon before performing mitral valve surgery.

  10. Factors influencing mortality after bioprosthetic valve replacement; a midterm outcome.

    PubMed

    Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar

    2013-01-01

    Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population.

  11. Surgical outcomes in native valve infectious endocarditis: the experience of the Cardiovascular Surgery Department - Cluj-Napoca Heart Institute.

    PubMed

    Molnar, Adrian; Muresan, Ioan; Trifan, Catalin; Pop, Dana; Sacui, Diana

    2015-01-01

    The introduction of Duke's criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. The patients' age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases - 21%), Staphylococcus Spp. (15 cases - 15%), and Enterococcus Spp. (9 cases - 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases - 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases - 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases - 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve - mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological examination of valve pieces excised during surgery was

  12. Valve replacement in children: a challenge for a whole life.

    PubMed

    Henaine, Roland; Roubertie, François; Vergnat, Mathieu; Ninet, Jean

    2012-10-01

    Valvular pathology in infants and children poses numerous challenges to the paediatric cardiac surgeon. Without question, valvular repair is the goal of intervention because restoration of valvular anatomy and physiology using native tissue allows for growth and a potentially better long-term outcome. When reconstruction fails or is not feasible, valve replacement becomes inevitable. Which valve for which position is controversial. Homograft and bioprosthetic valves achieve superior haemodynamic results initially but at the cost of accelerated degeneration. Small patient size and the risk of thromboembolism limit the usefulness of mechanical valves, and somatic outgrowth is an universal problem with all available prostheses. The goal of this article is to address valve replacement options for all four valve positions within the paediatric population. We review current literature and our practice to support our preferences. To summarize, a multitude of opinions and surgical experiences exist. Today, the valve choices that seem without controversy are bioprosthetic replacement of the tricuspid valve and Ross or Ross-Konno procedures when necessary for the aortic valve. On the other hand, bioprostheses may be implanted when annular pulmonary diameter is adequate; if not or in case of right ventricular outflow tract discontinuity, it is better to use a pulmonary homograft with the Ross procedure. Otherwise, a valved conduit. Mitral valve replacement remains the most problematic; the mechanical prosthesis must be placed in the annular position, avoiding oversizing. Future advances with tissue-engineered heart valves for all positions and new anticoagulants may change the landscape for valve replacement in the paediatric population. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  13. Society of Thoracic Surgeons 2008 cardiac risk models predict in-hospital mortality of heart valve surgery in a Chinese population: a multicenter study.

    PubMed

    Wang, Lv; Lu, Fang-Lin; Wang, Chong; Tan, Meng-Wei; Xu, Zhi-yun

    2014-12-01

    The Society of Thoracic Surgeons 2008 cardiac surgery risk models have been developed for heart valve surgery with and without coronary artery bypass grafting. The aim of our study was to evaluate the performance of Society of Thoracic Surgeons 2008 cardiac risk models in Chinese patients undergoing single valve surgery and the predicted mortality rates of those undergoing multiple valve surgery derived from the Society of Thoracic Surgeons 2008 risk models. A total of 12,170 patients underwent heart valve surgery from January 2008 to December 2011. Combined congenital heart surgery and aortal surgery cases were excluded. A relatively small number of valve surgery combinations were excluded. The final research population included the following isolated heart valve surgery types: aortic valve replacement, mitral valve replacement, and mitral valve repair. The following combined valve surgery types were included: mitral valve replacement plus tricuspid valve repair, mitral valve replacement plus aortic valve replacement, and mitral valve replacement plus aortic valve replacement and tricuspid valve repair. Evaluation was performed by using the Hosmer-Lemeshow test and C-statistics. Data from 9846 patients were analyzed. The Society of Thoracic Surgeons 2008 cardiac risk models showed reasonable discrimination and poor calibration (C-statistic, 0.712; P = .00006 in Hosmer-Lemeshow test). Society of Thoracic Surgeons 2008 models had better discrimination (C-statistic, 0.734) and calibration (P = .5805) in patients undergoing isolated valve surgery than in patients undergoing multiple valve surgery (C-statistic, 0.694; P = .00002 in Hosmer-Lemeshow test). Estimates derived from the Society of Thoracic Surgeons 2008 models exceeded the mortality rates of multiple valve surgery (observed/expected ratios of 1.44 for multiple valve surgery and 1.17 for single valve surgery). The Society of Thoracic Surgeons 2008 cardiac surgery risk models performed well when predicting the

  14. A retrospective study of clinical signs and epidemiology of chronic valve disease in a group of 207 Dachshunds in Poland

    PubMed Central

    2013-01-01

    Background Chronic mitral valve disease is frequently seen in the Dachshund. Dachshunds (n=207) made up 11.73% of the dogs admitted to the Cardiology Service at the Small Animal Clinic, Warsaw University of Life Sciences, Poland (first visits only). Results Of these, 35 dogs had no clinically detectable heart disease while 172 had chronic valve disease with the mitral valve affected most often (130 dogs), both mitral and tricuspid valves infrequently (39 dogs) and rarely the tricuspid valve (3 dogs). Males were affected more frequently than females and the average age of dogs with chronic valve disease was 11.9 years for females and 11.3 years for males. A majority of the diseased Dachshunds were classified as ISACHC 2 (79), followed by ISACHC 1 (60). Most frequent clinical signs noted by owners included coughing, exercise intolerance, dyspnea and tachypnea. Heart murmurs were generally louder with increased disease severity; however there were 20 dogs in the ISACHC 1 group with no audible heart murmurs. The most frequent electrocardiographic abnormalities included an increased P wave and QRS complex duration, increased R wave amplitude and tachycardia. With increased disease severity, echocardiography revealed an increase in heart size. A higher ISACHC class was related to increased heart size (based on echocardiography) and increased percentage of patients exhibiting enlargement of both left atrium and left ventricle (based on radiography). Conclusions The Dachshund is often affected by chronic mitral valvular disease with a late onset of associated clinical signs and few cardiac complications. PMID:23844824

  15. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    PubMed

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  16. Comparison of tricuspid inflow and superior vena caval Doppler velocities in acute simulated hypovolemia: new non-invasive indices for evaluating right ventricular preload.

    PubMed

    Liu, Jie; Cao, Tie-Sheng; Yuan, Li-Jun; Duan, Yun-You; Yang, Yi-Lin

    2006-05-16

    Assessment of cardiac preload is important for clinical management of some emergencies related to hypovolemia. Effects of acute simulated hypovolemia on Doppler blood flow velocity indices of tricuspid valve (TV) and superior vena cava (SVC) were investigated in order to find sensitive Doppler indices for predicting right ventricular preload. Doppler flow patterns of SVC and TV in 12 healthy young men were examined by transthoracic echocardiography (TTE) during graded lower body negative pressure (LBNP) of up to -60 mm Hg which simulated acute hypovolemia. Peak velocities of all waves and their related ratios (SVC S/D and tricuspid E/A) were measured, calculated and statistically analyzed. Except for the velocity of tricuspid A wave, velocities of all waves and their related ratios declined during volume decentralization. Of all indices measured, the peak velocities of S wave and AR wave in SVC correlated most strongly with levels of LBNP (r = -0.744 and -0.771, p < 0.001). The S and AR velocities are of good values in assessing right ventricular preload. Monitoring SVC flow may provide a relatively noninvasive means to assess direct changes in right ventricular preload.

  17. Surgical outcomes in native valve infectious endocarditis: the experience of the Cardiovascular Surgery Department – Cluj-Napoca Heart Institute

    PubMed Central

    MOLNAR, ADRIAN; MURESAN, IOAN; TRIFAN, CATALIN; POP, DANA; SACUI, DIANA

    2015-01-01

    Background and aims The introduction of Duke’s criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. Methods We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. Results The patients’ age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases – 21%), Staphylococcus Spp. (15 cases – 15%), and Enterococcus Spp. (9 cases – 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases – 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases – 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases – 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve – mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological

  18. Tricuspid Annular Geometry: A Three-Dimensional Transesophageal Echocardiographic Study

    PubMed Central

    Mahmood, Feroze; Kim, Han; Chaudary, Bilal; Bergman, Remco; Matyal, Robina; Gerstle, Jeniffer; Gorman, Joseph H.; Gorman, Robert C.; Khabbaz, Kamal R.

    2013-01-01

    Objective To demonstrate the clinical feasibility of accurately measuring tricuspid annular area by 3-dimensional (3D) transesophageal echocardiography (TEE) and to assess the geometric differences based on the presence of tricuspid regurgitation (TR). Also, the shape of the tricuspid annulus was compared with previous descriptions in the literature. Design Prospective. Setting Tertiary care university hospital. Interventions Three-dimensional TEE. Participants Patients undergoing cardiac surgery. Measurements and Main Results Volumetric data sets from 20 patients were acquired by 3D TEE and prospectively analyzed. Comparisons in annular geometry were made between groups based on the presence of TR. The QLab (Philips Medical Systems, Andover, MA) software package was used to calculate tricuspid annular area by both linear elliptical dimensions and planimetry. Further analyses were performed in the 4D Cardio-View (TomTec Corporation GmBH, Munich, Germany) and MATLAB (Natick, MA) software environments to accurately assess annular shape. It was found that patients with greater TR had an eccentrically dilated annulus with a larger annular area. Also, the area as measured by the linear ellipse method was overestimated as compared to the planimetry method. Furthermore, the irregular saddle-shaped geometry of the tricuspid annulus was confirmed through the mathematic model developed by the authors. Conclusions Three-dimensional TEE can be used to measure the tricuspid annular area in a clinically feasible fashion, with an eccentric dilation seen in patients with TR. The tricuspid annulus shape is complex, with annular high and low points, and annular area calculation based on linear measurements significantly overestimates 3D planimetered area. PMID:23725682

  19. The occurrence and suspected mode of inheritance of congenital subaortic stenosis and tricuspid valve dysplasia in Dogue de Bordeaux dogs.

    PubMed

    Ohad, D G; Avrahami, A; Waner, T; David, L

    2013-08-01

    The Dogue de Bordeaux (DdB) breed has gone through several genetic 'bottle necks' and has a relatively small effective population size. Importing new stock into Israel has been limited, further narrowing the already restricted local gene-pool and increasing the chances of inherited defects. In 56 DdB dogs examined between 2003 and 2010, the authors sought to study the proportion congenital subaortic stenosis (SAS) and tricuspid valve dysplasia (TVD). The aim was also to identify a probable mode of inheritance (MOI) using segregation and pedigree analyses of genealogical data available from 13/21 DdB dogs diagnosed with these conditions between 2004 and 2007. Among all breeds in the country, TVD was highest in the DdB breed, which also displayed the second highest proportion of SAS. Echocardiographic measurements and selected physical examination findings from 26 normal DdB dogs, 18 DdB dogs with SAS, and 12 DdB dogs with TVD are reported. Based on pedigree and segregation analyses, the most probable MOI appeared to be autosomal recessive. Pedigree analyses helped to identify three ancestors that might have introduced these two congenital heart defects into the local DdB population. Excluding those three dogs and their progeny from future mating could therefore reduce the prevalence of these diseases in the DdB population in Israel. The unusual local breeding circumstances may offer a unique opportunity to identify associated SAS and TVD genes in the DdB, as well as in other dog breeds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management.

    PubMed

    Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi

    2006-01-01

    Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.

  1. Pivot design in bileaflet valves.

    PubMed

    Vallana, F; Rinaldi, S; Galletti, P M; Nguyen, A; Piwnica, A

    1992-01-01

    The design criteria leading to the development of a new bileaflet valve (Sorin Bicarbon) were derived from the analysis of functional requirements, the performance of existing prostheses, and the availability of an advanced carbon coating technology (Carbofilm). The hinge is the critical element affecting fluid dynamics, durability, and thrombus formation in bileaflet valves. A comparative study of three existing models led to a new hinge design that was based on coupling two spheric surfaces with different radii of curvature (leaflet pivot and hinge recess) and obtained by electroerosion into a Carbofilm-coated metallic housing. In this valve, the point of contact moves continuously by rolling, not sliding. This minimizes friction and wear and allows uninterrupted washing of the blood exposed surfaces even during diastole (a finding established in patients using transesophageal echocardiography). Tricuspid implantation without anticoagulation in 33 sheep did not lead to thrombotic events (follow-up, 40-400 days). In the first 36 clinical implants observed for 15 months (mitral position, size 29; two unrelated deaths), the mean diastolic gradient by echo Doppler was 4 +/- 1.25 mmHg; the functional area was 3.2 +/- 0.6 cm2. No leaflet fracture and no thrombotic or embolic complications were observed clinically using a standard anticoagulant regimen.

  2. Factors Influencing Mortality after Bioprosthetic Valve Replacement; A Midterm Outcome

    PubMed Central

    Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar

    2013-01-01

    Introduction: Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Methods: Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Results: Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Conclusion: Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population. PMID:24404348

  3. The total right/left-volume index: a new and simplified cardiac magnetic resonance measure to evaluate the severity of Ebstein anomaly of the tricuspid valve: a comparison with heart failure markers from various modalities.

    PubMed

    Hösch, Olga; Sohns, Jan Martin; Nguyen, Thuy-Trang; Lauerer, Peter; Rosenberg, Christina; Kowallick, Johannes Tammo; Kutty, Shelby; Unterberg, Christina; Schuster, Andreas; Faßhauer, Martin; Staab, Wieland; Paul, Thomas; Lotz, Joachim; Steinmetz, Michael

    2014-07-01

    The classification of clinical severity of Ebstein anomaly still remains a challenge. The aim of this study was to focus on the interaction of the pathologically altered right heart with the anatomically-supposedly-normal left heart and to derive from cardiac magnetic resonance (CMR) a simple imaging measure for the clinical severity of Ebstein anomaly. Twenty-five patients at a mean age of 26±14 years with unrepaired Ebstein anomaly were examined in a prospective study. Disease severity was classified using CMR volumes and functional measurements in comparison with heart failure markers from clinical data, ECG, laboratory and cardiopulmonary exercise testing, and echocardiography. All examinations were completed within 24 hours. A total right/left-volume index was defined from end-diastolic volume measurements in CMR: total right/left-volume index=(RA+aRV+fRV)/(LA+LV). Mean total right/left-volume index was 2.6±1.7 (normal values: 1.1±0.1). This new total right/left-volume index correlated with almost all clinically used biomarkers of heart failure: brain natriuretic peptide (r=0.691; P=0.0003), QRS (r=0.432; P=0.039), peak oxygen consumption/kg (r=-0.479; P=0.024), ventilatory response to carbon dioxide production at anaerobic threshold (r=0.426; P=0.048), the severity of tricuspid regurgitation (r=0.692; P=0.009), tricuspid valve offset (r=0.583; P=0.004), and tricuspid annular plane systolic excursion (r=0.554; P=0.006). Previously described severity indices ([RA+aRV]/[fRV+LA+LV]) and fRV/LV end-diastolic volume corresponded only to some parameters. In patients with Ebstein anomaly, the easily acquired index of right-sided to left-sided heart volumes from CMR correlated well with established heart failure markers. Our data suggest that the total right/left-volume index should be used as a new and simplified CMR measure, allowing more accurate assessment of disease severity than previously described scoring systems. © 2014 American Heart Association, Inc.

  4. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    PubMed Central

    2012-01-01

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function. PMID:22747790

  5. Myoarchitecture and connective tissue in hearts with tricuspid atresia

    PubMed Central

    Sanchez-Quintana, D; Climent, V; Ho, S; Anderson, R

    1999-01-01

    Objective—To compare the atrial and ventricular myoarchitecture in the normal heart and the heart with tricuspid atresia, and to investigate changes in the three dimensional arrangement of collagen fibrils.
Methods—Blunt dissection and cell maceration with scanning electron microscopy were used to study the architecture of the atrial and ventricular musculature and the arrangement of collagen fibrils in three specimens with tricuspid atresia and six normal human hearts.
Results—There were significant modifications in the myoarchitecture of the right atrium and the left ventricle, both being noticeably hypertrophied. The middle layer of the ventricle in the abnormal hearts was thicker than in the normal hearts. The orientation of the superficial layer in the left ventricle in hearts with tricuspid atresia was irregular compared with the normal hearts. Scanning electron microscopy showed coarser endomysial sheaths and denser perimysial septa in hearts with tricuspid atresia than in normal hearts.
Conclusions—The overall architecture of the muscle fibres and its connective tissue matrix in hearts with tricuspid atresia differed from normal, probably reflecting modelling of the myocardium that is inherent to the malformation. This is in concordance with clinical observations showing deterioration in pump function of the dominant left ventricle from very early in life.

 Keywords: tricuspid atresia; congenital heart defects; connective tissue; fibrosis PMID:9922357

  6. Bicuspid aortic valve hemodynamics: a fluid-structure interaction study

    NASA Astrophysics Data System (ADS)

    Chandra, Santanu; Seaman, Clara; Sucosky, Philippe

    2011-11-01

    The bicuspid aortic valve (BAV) is a congenital defect in which the aortic valve forms with two leaflets instead of three. While calcific aortic valve disease (CAVD) also develops in the normal tricuspid aortic valve (TAV), its progression in the BAV is more rapid. Although studies have suggested a mechano-potential root for the disease, the native BAV hemodynamics remains largely unknown. This study aimed at characterizing BAV hemodynamics and quantifying the degree of wall-shear stress (WSS) abnormality on BAV leaflets. Fluid-structure interaction models validated with particle-image velocimetry were designed to predict the flow and leaflet dynamics in idealized TAV and BAV anatomies. Valvular function was quantified in terms of the effective orifice area. The regional leaflet WSS was characterized in terms of oscillatory shear index, temporal shear magnitude and temporal shear gradient. The predictions indicate the intrinsic degree of stenosis of the BAV anatomy, reveal drastic differences in shear stress magnitude and pulsatility on BAV and TAV leaflets and confirm the side- and site-specificity of the leaflet WSS. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, these results support the existence of a mechano-etiology of CAVD in the BAV.

  7. Mitral annular calcification in patients undergoing aortic valve replacement for aortic valve stenosis.

    PubMed

    Takami, Yoshiyuki; Tajima, Kazuyoshi

    2016-02-01

    Limited data exis t on clinical relevance of aortic valve stenosis (AVS) and mitral annular calcification (MAC), although with similar pathophysiologic basis. We sought to reveal the prevalence of MAC and its clinical features in the patients undergoing aortic valve replacement (AVR) for AVS. We reviewed 106 consecutive patients who underwent isolated AVR from 2004 to 2010. Before AVR, CT scans were performed to identify MAC, whose severity was graded on a scale of 0-4, with grade 0 denoting no MAC and grade 4 indicating severe MAC. Echocardiography was performed before AVR and at follow-up over 2 years after AVR. MAC was identified in 56 patients with grade 1 (30 %), 2 (39 %), 3 (18 %), and 4 (13 %), respectively. Patients with MAC presented older age (72 ± 8 versus 66 ± 11 years), higher rate of dialysis-dependent renal failure (43 versus 4 %), and less frequency of bicuspid aortic valve (9 versus 36 %), when compared to those without MAC. No significant differences were seen in short- and mid-term mortality after AVR between the groups. In patients with MAC, progression of neither mitral regurgitation nor stenosis was observed at follow-up of 53 ± 23 months for 102 survivors, although the transmitral flow velocities were higher than in those without MAC. In conclusion, MAC represented 53 % of the patients undergoing isolated AVR for AVS, usually appeared in dialysis-dependent elder patients with tricuspid AVS. MAC does not affect adversely upon the survival, without progression of mitral valve disease, at least within 2 years after AVR.

  8. C-reactive protein in degenerative aortic valve stenosis

    PubMed Central

    Sanchez, Pedro L; Mazzone, AnnaMaria

    2006-01-01

    Degenerative aortic valve stenosis includes a range of disorder severity from mild leaflet thickening without valve obstruction, "aortic sclerosis", to severe calcified aortic stenosis. It is a slowly progressive active process of valve modification similar to atherosclerosis for cardiovascular risk factors, lipoprotein deposition, chronic inflammation, and calcification. Systemic signs of inflammation, as wall and serum C-reactive protein, similar to those found in atherosclerosis, are present in patients with degenerative aortic valve stenosis and may be expression of a common disease, useful in monitoring of stenosis progression. PMID:16774687

  9. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    PubMed

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  10. Tricuspid but not Mitral Regurgitation Determines Mortality After TAVI in Patients With Nonsevere Mitral Regurgitation.

    PubMed

    Amat-Santos, Ignacio J; Castrodeza, Javier; Nombela-Franco, Luis; Muñoz-García, Antonio J; Gutiérrez-Ibanes, Enrique; de la Torre Hernández, José M; Córdoba-Soriano, Juan G; Jiménez-Quevedo, Pilar; Hernández-García, José M; González-Mansilla, Ana; Ruano, Javier; Tobar, Javier; Del Trigo, María; Vera, Silvio; Puri, Rishi; Hernández-Luis, Carolina; Carrasco-Moraleja, Manuel; Gómez, Itziar; Rodés-Cabau, Josep; San Román, José A

    2018-05-01

    Many patients undergoing transcatheter aortic valve implantation (TAVI) have concomitant mitral regurgitation (MR) of moderate grade or less. The impact of coexistent tricuspid regurgitation (TR) remains to be determined. We sought to analyze the impact of moderate vs none-to-mild MR and its trend after TAVI, as well as the impact of concomitant TR and its interaction with MR. Multicenter retrospective study of 813 TAVI patients treated through the transfemoral approach with MR ≤ 2 between 2007 and 2015. The mean age was 81 ± 7 years and the mean Society of Thoracic Surgeons score was 6.9% ± 5.1%. Moderate MR was present in 37.3% of the patients, with similar in-hospital outcomes and 6-month follow-up mortality to those with MR < 2 (11.9% vs 9.4%; P = .257). However, they experienced more rehospitalizations and worse New York Heart Association class (P = .008 and .001, respectively). Few patients (3.8%) showed an increase in the MR grade to > 2 post-TAVI. The presence of concomitant moderate/severe TR was associated with in-hospital and follow-up mortality rates of 13% and 34.1%, respectively, regardless of MR grade. Moderate-severe TR was independently associated with mortality (HR, 18.4; 95%CI, 10.2-33.3; P < .001). The presence of moderate MR seemed not to impact short- and mid-term mortality post-TAVI, but was associated with more rehospitalizations. The presence of moderate or severe TR was associated with higher mortality. This suggests that a thorough evaluation of the mechanisms underlying concomitant mitral and tricuspid valve regurgitation should be performed to determine the best strategy for avoiding TAVI-related futility. Copyright © 2018 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  11. Patient-specific pediatric silicone heart valve models based on 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Ilina, Anna; Lasso, Andras; Jolley, Matthew A.; Wohler, Brittany; Nguyen, Alex; Scanlan, Adam; Baum, Zachary; McGowan, Frank; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons' feedback.

  12. Isolated tricuspid regurgitation: outcomes and therapeutic interventions

    PubMed Central

    Zack, Chad J; Nishimura, Rick A

    2018-01-01

    Isolated tricuspid regurgitation (TR) can be caused by primary valvular abnormalities such as flail leaflet or secondary annular dilation as is seen in atrial fibrillation, pulmonary hypertension and left heart disease. There is an increasing recognition of a subgroup of patients with isolated TR in the absence of other associated cardiac abnormalities. Left untreated isolated TR significantly worsens survival. Stand-alone surgery for isolated TR is rarely performed due to an average operative mortality of 8%–10% and a paucity of data demonstrating improved survival. When surgery is performed, valve repair may be preferred over replacement; however, there is a risk of significant recurrent regurgitation after repair. Existing society guidelines do not fully address the management of isolated TR. We propose that patients at low operative risk with symptomatic severe isolated TR and no reversible cause undergo surgery prior to the onset of right ventricular dysfunction and end-organ damage. For patients at increased surgical risk novel percutaneous interventions may offer an alternative treatment but further research is needed. Significant knowledge gaps remain and future research is needed to define operative outcomes and provide comparative data for medical and surgical therapy. PMID:29229649

  13. Review of Congenital Mitral Valve Stenosis: Analysis, Repair Techniques and Outcomes.

    PubMed

    Baird, Christopher W; Marx, Gerald R; Borisuk, Michele; Emani, Sitram; del Nido, Pedro J

    2015-06-01

    The spectrum of congenital mitral valve stenosis (MS) consists of a complex of defects that result in obstruction to left ventricular inflow. This spectrum includes patients with underdeveloped left heart structures (Fig. 1) to those with isolated congenital MS. The specific mitral valve defects can further be divided into categories based on the relationship to the mitral valve annulus including valvar, supravalvar and subvalvar components. Clinically, these patients present based on the degree of obstruction, associated mitral regurgitation, secondary pulmonary hypertension, associated lung disease and/or associated cardiac lesions. There are a number of factors that contribute to the successful outcomes in these patients including pre-operative imaging, aggressive surgical techniques and peri-operative management.

  14. [Experimental studies of original valved conduit using glutaraldehyde-preserved equine pericardium (Xenomedica)].

    PubMed

    Murakami, T

    1989-05-01

    Extracardiac conduits, such as Dacron or homo-graft, have been utilized for the operative management of many patients with congenital right ventricular outflow obstruction. However, they have been recognized to become obstructed or calcified with time. As a new material for extracardiac conduit, an original valved conduit using glutaraldehyde-preserved equine pericardium (Xenomedica) was investigated. Various types of valved conduit were evaluated for the hydrodynamics by a circulation system. A flow-pressure gradient Lissajous was used for the evaluation. The conduit of 10 mm in diameter had a high resistance to flow. The monocusp-valved conduit had a diastolic regurgitation (DR) at any given pressures and heart rates. The bicusp-valved conduit had a DR at higher heart rates (greater than 153/min). In this experiment, the tricusp-valved conduit with a valvular vertical versus horizontal length ratio of 2:3 had utmost favorable results under any given conditions. The valved conduits were also evaluated using sixteen mongrel dogs in which the conduit were used for the reconstruction of continuity between right ventricle and pulmonary artery. Five dogs died of bacterial infection or thrombotic obstruction. Following hemodynamic studies, which were performed in eleven dogs 1, 6, and 12 months after the operation, the dogs were sacrificed to evaluate the histological changes in the conduits. The valvular function had been satisfactory until one month, however, it was lost in 6 months because the valvular leaflets were covered with neointimae grown over them. Thin neointimae were observed both at the sites of anastomosis and at the base of the valves in dogs sacrificed at one month. They spread from the proximal anastomotic site to distal one. They were organized and it was hard to remove them manually. Thrombi were found in six dogs at the proximal anastomotic site with intimal hyperplasia. There was no calcification in Xenomedica and its degenerative change was

  15. Echocardiographic versus histologic findings in Marfan syndrome.

    PubMed

    Gu, Xiaoyan; He, Yihua; Li, Zhian; Han, Jiancheng; Chen, Jian; Nixon, J V Ian

    2015-02-01

    This retrospective study attempted to establish the prevalence of multiple-valve involvement in Marfan syndrome and to compare echocardiographic with histopathologic findings in Marfan patients undergoing valvular or aortic surgery. We reviewed echocardiograms of 73 Marfan patients who underwent cardiovascular surgery from January 2004 through October 2009. Tissue histology was available for comparison in 29 patients. Among the 73 patients, 66 underwent aortic valve replacement or the Bentall procedure. Histologic findings were available in 29 patients, all of whom had myxomatous degeneration. Of 63 patients with moderate or severe aortic regurgitation as determined by echocardiography, 4 had thickened aortic valves. The echocardiographic findings in 18 patients with mitral involvement included mitral prolapse in 15. Of 11 patients with moderate or severe mitral regurgitation as determined by echocardiography, 4 underwent mitral valve repair and 7 mitral valve replacement. Histologic findings among mitral valve replacement patients showed thickened valve tissue and myxomatous degeneration. Tricuspid involvement was seen echocardiographically in 8 patients, all of whom had tricuspid prolapse. Two patients had severe tricuspid regurgitation, and both underwent repair. Both mitral and tricuspid involvement were seen echocardiographically in 7 patients. Among the 73 patients undergoing cardiac surgery for Marfan syndrome, 66 had moderate or severe aortic regurgitation, although their valves manifested few histologic changes. Eighteen patients had mitral involvement (moderate or severe mitral regurgitation, prolapse, or both), and 8 had tricuspid involvement. Mitral valves were most frequently found to have histologic changes, but the tricuspid valve was invariably involved.

  16. Mechanisms of tricuspid regurgitation in patients with hypoplastic left heart syndrome undergoing tricuspid valvuloplasty.

    PubMed

    Bautista-Hernandez, Victor; Brown, David W; Loyola, Hugo; Myers, Patrick O; Borisuk, Michele; del Nido, Pedro J; Baird, Christopher W

    2014-09-01

    Tricuspid regurgitation (TR) remains a risk factor for morbidity and mortality through staged palliation in patients with hypoplastic left heart syndrome (HLHS). Reports on the mechanisms associated with TR in patients with HLHS are limited. Thus, we sought to describe our experience with tricuspid valve (TV) repair in these patients, focusing on the mechanisms of TR and corresponding surgical techniques. We performed a retrospective single-center review (January 2000 to December 2012) of patients with HLHS undergoing TV repair and completing Fontan circulation. We evaluated the pre- and postoperative echocardiograms, intraoperative findings, and surgical techniques used. A total of 53 TV repairs were performed in 35 patients with HLHS completing staged palliation. TV repairs were performed at stage II in 15, between stage II and III in 4, at stage III in 27, and after stage III in 7. The surgical techniques for valvuloplasty included annuloplasty (38%), anteroseptal (AS) commissuroplasty (66%), anterior papillary muscle repositioning (11%), multiple commissuroplasties (9%), septal-posterior commissuroplasty (9%), and fenestration closure (4%). The predominant jet of TR emanated along the AS commissure in 68% of the cases. All patients survived the procedure and were discharged. Preoperative echocardiography showed a dilated TV annulus on the lateral dimension, anteroposterior dimension, and area that was significantly reduced after TV repair (P < .0001). The preoperative mean TR, as assessed by lateral (P = .002) and anteroposterior (P = .005) vena contracta, was also significantly reduced after TV repair. TV repair did not significantly affect right ventricular systolic function immediately after surgery (P = .17) or at the most recent follow-up visit (P = .52). Patients with anterior leaflet prolapse were at increased risk of worse outcomes, including moderate or greater right ventricular dysfunction (P = .02). Patients requiring reoperation for TV repair were

  17. 3D printing of normal and pathologic tricuspid valves from transthoracic 3D echocardiography data sets.

    PubMed

    Muraru, Denisa; Veronesi, Federico; Maddalozzo, Anna; Dequal, Daniele; Frajhof, Leonardo; Rabischoffsky, Arnaldo; Iliceto, Sabino; Badano, Luigi P

    2017-07-01

    To explore the feasibility of using transthoracic 3D echocardiography (3DTTE) data to generate 3D patient-specific models of tricuspid valve (TV). Multi-beat 3D data sets of the TV (32 vol/s) were acquired in five subjects with various TV morphologies from the apical approach and analysed offline with custom-made software. Coordinates representing the annulus and the leaflets were imported into MeshLab (Visual Computing Lab ISTICNR) to develop solid models to be converted to stereolithographic file format and 3D print. Measurements of the TV annulus antero-posterior (AP) and medio-lateral (ML) diameters, perimeter (P), and TV tenting height (H) and volume (V) obtained from the 3D echo data set were compared with those performed on the 3D models using a caliper, a syringe and a millimeter tape. Antero-posterior (4.2 ± 0.2 cm vs. 4.2 ± 0 cm), ML (3.7 ± 0.2 cm vs. 3.6 ± 0.1 cm), P (12.6 ± 0.2 cm vs. 12.7 ± 0.1 cm), H (11.2 ± 2.1 mm vs. 10.8 ± 2.1 mm) and V (3.0 ± 0.6 ml vs. 2.8 ± 1.4 ml) were similar (P = NS for all) when measured on the 3D data set and the printed model. The two sets of measurements were highly correlated (r = 0.991). The mean absolute error (2D - 3D) for AP, ML, P and tenting H was 0.7 ± 0.3 mm, indicating accuracy of the 3D model of <1 mm. Three-dimensional printing of the TV from 3DTTE data is feasible with highly conserved fidelity. This technique has the potential for rapid integration into clinical practice to assist with decision-making, surgical planning, and teaching. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions, please email: journals.permissions@oup.com.

  18. Heart valve disease associated with treatment with ergot-derived dopamine agonists: a clinical and echocardiographic study of patients with Parkinson's disease.

    PubMed

    Rasmussen, V G; Poulsen, S H; Dupont, E; Østergaard, K; Safikhany, G; Egeblad, H

    2008-01-01

    To elucidate the association between treatment with ergot-derived dopamine agonists (EDDA) and valvular abnormalities amongst patients with idiopathic Parkinson's disease (IPD) and secondly, to analyse the yield of clinical screening for valvular heart disease. A cross-sectional controlled study. The cohort of IPD patients treated in the outpatient clinic, Department of Neurology, Aarhus University Hospital, Denmark. A total of 138 IPD patients [median age 64 (39-87) years, 62% men] treated with either EDDA (n = 85) or non-EDDA (n = 53) for at least 6 months. Interventions. Patients were screened for valvular heart disease by clinical means and by examiner-blinded echocardiography. Main outcome measure was valvular regurgitation revealed by echocardiography. Severe aortic regurgitation (n = 4) or moderate aortic (n = 12), mitral (n = 3) or tricuspidal valve regurgitation (n = 5) was found in 22 EDDA patients (25.9%). Two patients had coexistent moderate mitral and tricuspid valvular regurgitation. Two non-EDDA patients had moderate valve insufficiency (3.8%, P < 0.05). The adjusted relative risk for at least moderate valve insufficiency in the EDDA patients was 7.2% (P < 0.05). The sensitivity of detecting at least moderate valvular disease by cardiac murmur, dyspnoea, or the heart failure marker NT-proBNP (natriuretic peptide) was 62% for the neurologists and 93% for the cardiologist but with equally low specificity (30-35%). EDDA was associated with a clinically important and statistically significant risk of at least moderate valve regurgitation. Clinical screening for valve disease was inadequate and it seems advisable to offer EDDA patients control with echocardiography.

  19. Trans-catheter aortic valve implantation after previous aortic homograft surgery.

    PubMed

    Drews, Thorsten; Pasic, Miralem; Buz, Semih; Unbehaun, Axel

    2011-12-01

    In patients with previous heart surgery, the operative risk is elevated during conventional aortic valve re-operations. Trans-catheter aortic valve implantation is a new method for the treatment of high-risk patients. Nevertheless, this new procedure carries potential risks in patients with previous homograft implantation in aortic position. Between April 2008 and February 2011, 345 consecutive patients (mean EuroSCORE (European System for Cardiac Operative Risk Evaluation): 38 ± 20%; mean Society of Thoracic Surgeons (STS) Mortality Score: 19 ± 16%; mean age: 80 ± 8 years; 111 men and 234 women) underwent trans-apical aortic valve implantation. In three patients, previous aortic homograft implantation had been performed. Homograft degeneration causing combined valve stenosis and incompetence made re-operation necessary. In all three patients, the aortic valve could be implanted using the trans-apical approach, and the procedure was successful. In two patients, there was slight paravalvular leakage of the aortic prosthesis and the other patient had slight central leakage. Neither ostium obstruction nor mitral valve damage was observed. Trans-catheter valve implantation can be performed successfully after previous homograft implantation. Particular care should be taken to achieve optimal valve positioning, not to obstruct the ostium of the coronary vessels due to the changed anatomic situation and not to cause annulus rupture. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  20. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    PubMed

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  1. [A case report of Ebstein's anomaly treated with Hetzer's procedure].

    PubMed

    Sako, H; Hadama, T; Shigemitsu, O; Miyamoto, S; Anai, H; Wada, T; Iwata, E; Mori, Y; Soeda, T; Takakura, K

    2001-02-01

    A 27-year-old male who had been diagnosed with Ebstein's anomaly was admitted with uncontrollable congestive heart failure. The echocardiogram revealed severe tricuspid valve incompetence and the electrocardiogram showed atrial fibrillation. He underwent Hetzer's repair procedure for tricuspid valve incompetence and Minzioni's right atrial isolation technique to restore sinus rhythm. His congestive heart failure quickly disappeared and sinus rhythm was restored after operation. He was discharged 3 weeks postoperatively and remains well 22 months after his operation. Hetzer's technique for tricuspid valve repair in Ebstein's anomaly restructures the valve mechanism at the level of the true tricuspid anulus by using the most mobile leaflet for valve closure without plication of the atrialized chamber. We conclude that Hetzer's procedure is an effective operation for Ebstein's anomaly.

  2. Automated segmentation and geometrical modeling of the tricuspid aortic valve in 3D echocardiographic images.

    PubMed

    Pouch, Alison M; Wang, Hongzhi; Takabe, Manabu; Jackson, Benjamin M; Sehgal, Chandra M; Gorman, Joseph H; Gorman, Robert C; Yushkevich, Paul A

    2013-01-01

    The aortic valve has been described with variable anatomical definitions, and the consistency of 2D manual measurement of valve dimensions in medical image data has been questionable. Given the importance of image-based morphological assessment in the diagnosis and surgical treatment of aortic valve disease, there is considerable need to develop a standardized framework for 3D valve segmentation and shape representation. Towards this goal, this work integrates template-based medial modeling and multi-atlas label fusion techniques to automatically delineate and quantitatively describe aortic leaflet geometry in 3D echocardiographic (3DE) images, a challenging task that has been explored only to a limited extent. The method makes use of expert knowledge of aortic leaflet image appearance, generates segmentations with consistent topology, and establishes a shape-based coordinate system on the aortic leaflets that enables standardized automated measurements. In this study, the algorithm is evaluated on 11 3DE images of normal human aortic leaflets acquired at mid systole. The clinical relevance of the method is its ability to capture leaflet geometry in 3DE image data with minimal user interaction while producing consistent measurements of 3D aortic leaflet geometry.

  3. Echocardiography-based spectrum of severe tricuspid regurgitation: the frequency of apparently idiopathic tricuspid regurgitation.

    PubMed

    Mutlak, Diab; Lessick, Jonathan; Reisner, Shimon A; Aronson, Doron; Dabbah, Salim; Agmon, Yoram

    2007-04-01

    The cause of tricuspid valve (TV) regurgitation (TR) occasionally remains unclear. The objectives of our study were to define the causal spectrum of severe TR diagnosed by echocardiography at a tertiary medical center and to assess the relative frequency and determine the clinical and echocardiographic characteristics of TR without an apparent cause (idiopathic TR). Consecutive patients with severe TR were identified by the echocardiography laboratory computerized database. The echocardiographic reports of all patients were reviewed and the causes of TR were determined. The echocardiographic studies and medical charts were reviewed in patients without an obvious cause of TR. Of 242 consecutive patients diagnosed with severe TR, organic TV disease was evident in 23 patients (9.5%) and significant pulmonary hypertension (estimated pulmonary artery systolic pressure > 50 mm Hg) in an additional 157 patients (64.9%). After further excluding patients with various confounding factors, possibly associated with occult organic TV disease or significant pulmonary hypertension, 23 patients (9.5%) had severe TR without an apparent cause. Of these, TV coaptation appeared relatively intact, allowing adequate estimation of pulmonary artery pressure, in 15 patients (6.2% of all patients with severe TR; idiopathic TR group). Patients with idiopathic TR were older (76 +/- 10 years), with a high frequency of atrial fibrillation (93%), and prominent TV annular dilatation. After excluding multiple potential causes of TR, severe TR is occasionally idiopathic. Annular dilatation (secondary to aging, atrial fibrillation, or other causes) is the likely mechanism of TR in these patients.

  4. Perforation of the right aortic valve cusp: complication of ventricular septal defect closure with a modified Rashkind umbrella.

    PubMed

    Vogel, M; Rigby, M L; Shore, D

    1996-01-01

    An 18-month-old boy with a perimembranous ventricular septal defect (VSD) had undergone transcatheter closure of the defect with a modified 17 mm Rashkind umbrella device at age 4 months (weight 3.8 kg). The clinical signs of a VSD persisted, and he developed aortic incompetence, first detected 5 months after the procedure, which progressed from mild to moderate. A three-dimensional echocardiographic study demonstrated that one of the four arms holding the umbrella was protruding into the aortic valve and had perforated the right aortic valve cusp. This diagnosis was confirmed at subsequent surgery. Surgical repair of the perforated right aortic valve leaflet was necessary. The umbrella was adherent to the tricuspid valve and could not be removed. Instead it was left in situ, but three of the stainless steel arms were cut off. When umbrella closure of a perimembranous VSD is undertaken, the close proximity of part of the distal umbrella to the aortic valve can lead to aortic regurgitation.

  5. Rapid pannus formation after few months of obstructing aortic mechanical prosthesis.

    PubMed

    Al-Alao, Bassel; Simoniuk, Urszula; Heron, Brian; Parissis, Haralabos

    2015-11-01

    We report a rare case of a prosthetic aortic valve obstruction due to pannus formation only 3 months following aortic and mitral valve replacement. Fragments of asymmetrical pannus formation affected one of the leaflets of the bi-leaflet mechanical valve; the leaflet appeared immobile due to pannus ingrowth into the mechanical skeleton resulting in encroachment of the leaflet, which in turn became immobile. The patient successfully underwent emergency redo-aortic valve replacement.

  6. Hyperthyroidism presenting as isolated tricuspid regurgitation and right heart failure.

    PubMed

    Whitner, Tanya E; Hudson, Christopher J; Smith, Timothy D; Littmann, Laszlo

    2005-01-01

    Although hyperthyroidism has many signs and symptoms, right heart failure can occasionally be the main presenting symptom. We describe the case of a previously healthy 42-year-old woman whose chief complaint was progressive bilateral lower extremity edema. The echocardiogram revealed right atrial dilatation and moderate-to-severe tricuspid regurgitation. Results of laboratory studies were consistent with hyperthyroidism. Thyroid ablation resulted in permanent resolution of symptoms and resolution of tricuspid incompetence on echocardiography. In a case of isolated, unexplained tricuspid regurgitation, it is important to consider indolent hyperthyroidism in the differential diagnosis.

  7. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    PubMed

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. Four-dimensional geometric assessment of tricuspid annulus movement in early functional tricuspid regurgitation patients indicates decreased longitudinal flexibility

    PubMed Central

    Maeba, Satoru; Taguchi, Takahiro; Midorikawa, Hirofumi; Kanno, Megumu; Sueda, Taijiro

    2013-01-01

    OBJECTIVES Functional tricuspid regurgitation (FTR) is generally caused by the dilation of the tricuspid annulus (TA) and the tethering of tricuspid leaflets; however, it also occurs in patients without dilatation of the TA. The aim of this study was to develop and to use a four-dimensional tracking system, utilizing cardiac magnetic resonance imaging (MRI), and to assess TA flexibility in patients with early FTR without right ventricle dilation as a preliminary investigation for the mechanism of early FTR. METHODS The structure and movement of the TA were examined in 20 healthy subjects and 19 FTR patients whose right ventricle was not dilated. We analysed the short axis and longitudinal movement of a mid-septal point (S), a mid-lateral point (L), a mid-anterior point (A) and a mid-posterior point (P) on the TA throughout the cardiac cycle. The tethering distance of the tricuspid leaflets and the integrated orbiting volume of the TA were also measured. RESULTS The TA area (mm2) and AP and LS distances (mm) did not differ significantly between the two groups, but the longitudinally moving distances (mm) of the four points were significantly shorter in patients with FTR than in healthy subjects. Also, the mean tethering distance (mm) was significantly longer in patients with FTR than in healthy subjects (9.0 ± 1.5 vs 4.0 ± 1.3, respectively; P < 0.001), and the integrated volume (mm3) of the annular moving track, throughout the cardiac cycle, was significantly larger in healthy subjects than in patients with FTR (40 428 ± 10 951 vs 22 967 ± 6079, P < 0.001). CONCLUSIONS The longitudinal flexibility of the TA in FTR patients was significantly less than that in the healthy subjects, and the tethering of the tricuspid leaflets occurred in FTR patients despite the absence of TA and RV dilation, which can be one triggering factor of early FTR. Four-dimensional geometric assessment, using cardiac MRI and the tracking program that we have developed, is capable of

  9. Four-dimensional geometric assessment of tricuspid annulus movement in early functional tricuspid regurgitation patients indicates decreased longitudinal flexibility.

    PubMed

    Maeba, Satoru; Taguchi, Takahiro; Midorikawa, Hirofumi; Kanno, Megumu; Sueda, Taijiro

    2013-06-01

    Functional tricuspid regurgitation (FTR) is generally caused by the dilation of the tricuspid annulus (TA) and the tethering of tricuspid leaflets; however, it also occurs in patients without dilatation of the TA. The aim of this study was to develop and to use a four-dimensional tracking system, utilizing cardiac magnetic resonance imaging (MRI), and to assess TA flexibility in patients with early FTR without right ventricle dilation as a preliminary investigation for the mechanism of early FTR. The structure and movement of the TA were examined in 20 healthy subjects and 19 FTR patients whose right ventricle was not dilated. We analysed the short axis and longitudinal movement of a mid-septal point (S), a mid-lateral point (L), a mid-anterior point (A) and a mid-posterior point (P) on the TA throughout the cardiac cycle. The tethering distance of the tricuspid leaflets and the integrated orbiting volume of the TA were also measured. The TA area (mm(2)) and AP and LS distances (mm) did not differ significantly between the two groups, but the longitudinally moving distances (mm) of the four points were significantly shorter in patients with FTR than in healthy subjects. Also, the mean tethering distance (mm) was significantly longer in patients with FTR than in healthy subjects (9.0 ± 1.5 vs 4.0 ± 1.3, respectively; P < 0.001), and the integrated volume (mm(3)) of the annular moving track, throughout the cardiac cycle, was significantly larger in healthy subjects than in patients with FTR (40 428 ± 10 951 vs 22 967 ± 6079, P < 0.001). The longitudinal flexibility of the TA in FTR patients was significantly less than that in the healthy subjects, and the tethering of the tricuspid leaflets occurred in FTR patients despite the absence of TA and RV dilation, which can be one triggering factor of early FTR. Four-dimensional geometric assessment, using cardiac MRI and the tracking program that we have developed, is capable of determining TA structure and flexibility.

  10. Differentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: a review of the literature.

    PubMed

    Tanis, Wilco; Habets, Jesse; van den Brink, Renee B A; Symersky, Petr; Budde, Ricardo P J; Chamuleau, Steven A J

    2014-02-01

    For acquired mechanical prosthetic heart valve (PHV) obstruction and suspicion on thrombosis, recently updated European Society of Cardiology guidelines advocate the confirmation of thrombus by transthoracic echocardiography, transesophageal echocardiography (TEE), and fluoroscopy. However, no evidence-based diagnostic algorithm is available for correct thrombus detection, although this is clinically important as fibrinolysis is contraindicated in non-thrombotic obstruction (isolated pannus). Here, we performed a review of the literature in order to propose a diagnostic algorithm. We performed a systematic search in Pubmed and Embase. Included publications were assessed on methodological quality based on the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS) II checklist. Studies were scarce (n = 15) and the majority were of moderate methodological quality. In total, 238 mechanical PHV's with acquired obstruction and a reliable reference standard were included for the evaluation of the role of fluoroscopy, echocardiography, or multidetector-row computed tomography (MDCT). In acquired PHV obstruction caused by thrombosis, mass detection by TEE and leaflet restriction detected by fluoroscopy were observed in the majority of cases (96 and 100%, respectively). In contrast, in acquired PHV obstruction free of thrombosis (pannus), leaflet restriction detected by fluoroscopy was absent in some cases (17%) and mass detection by TEE was absent in the majority of cases (66%). In case of mass detection by TEE, predictors for obstructive thrombus masses (compared with pannus masses) were leaflet restriction, soft echo density, and increased mass length. In situations of inconclusive echocardiography, MDCT may correctly detect pannus/thrombus based on the morphological aspects and localization. In acquired mechanical PHV obstruction without leaflet restriction and absent mass on TEE, obstructive PHV thrombosis cannot be confirmed and consequently, fibrinolysis

  11. [Tricuspid insufficiency and right traumatic ventricular aneurysm. Apropos of a case].

    PubMed

    Boisselier, P; Lombaert, M; Rey, J L; Quiret, J C; Bernasconi, P

    1981-12-01

    Tricuspid incompetence associated with a right ventricular aneurysm wa discovered after a non-penetrating thoracic injury. The severity of the tricuspid lesion was confirmed by phonomechanography, catheterisation and angiography. The mechanism was demonstrated by two-dimensional echocardiography: the right ventricular aneurysm was located in the right ventricular outflow tract. As the hemodynamic tolerance was good, surgery was not performed. A review of the literature found 41 other reports of traumatic tricuspid incompetence, and 4 cases of right ventricular aneurysm, only one of which was associated with tricuspid regurgitation. The points of interest of ths case: the rarity of the association, the good hemodynamic tolerance and the value of two-dimensional echocardiography for the diagnosis of ruptured chordae in the absence of surgical observations.

  12. Mitral valve disease—morphology and mechanisms

    PubMed Central

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  13. Mitral stenosis and hypertrophic obstructive cardiomyopathy: An unusual combination.

    PubMed

    Hong, Joonhwa; Schaff, Hartzell V; Ommen, Steve R; Abel, Martin D; Dearani, Joseph A; Nishimura, Rick A

    2016-04-01

    Systolic anterior motion of mitral valve (MV) leaflets is a main pathophysiologic feature of left ventricular outflow tract (LVOT) obstruction in hypertrophic obstructive cardiomyopathy. Thus, restricted leaflet motion that occurs with MV stenosis might be expected to minimize outflow tract obstruction related to systolic anterior motion. From January 1993 through February 2015, we performed MV replacement and septal myectomy in 12 patients with mitral stenosis and hypertrophic obstructive cardiomyopathy at Mayo Clinic Hospital in Rochester, Minn. Preoperative data, echocardiographic images, operative records, and postoperative outcomes were reviewed. Mean (standard deviation) age was 70 (7.6) years. Preoperative mean (standard deviation) maximal LVOT pressure gradient was 75.0 (35.0) mm Hg; MV gradient was 13.7 (2.8) mm Hg. From echocardiographic images, 4 mechanisms of outflow tract obstruction were identified: systolic anterior motion without severe limitation in MV leaflet excursion, severe limitation in MV leaflet mobility with systolic anterior motion at the tip of the MV anterior leaflet, septal encroachment toward the LVOT, and MV displacement toward the LVOT by calcification. Mitral valve replacement and extended septal myectomy relieved outflow gradients in all patients, with no death or serious morbidity. Patients with mitral stenosis and hypertrophic obstructive cardiomyopathy have multiple LVOT obstruction mechanisms, and MV replacement may not be adequate treatment. We favor septal myectomy and MV replacement in this complex subset of hypertrophic obstructive cardiomyopathy. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  14. Comparison of the structure of the aortic valve and ascending aorta in adults having aortic valve replacement for aortic stenosis versus for pure aortic regurgitation and resection of the ascending aorta for aneurysm.

    PubMed

    Roberts, William Clifford; Vowels, Travis James; Ko, Jong Mi; Filardo, Giovanni; Hebeler, Robert Frederick; Henry, Albert Carl; Matter, Gregory John; Hamman, Baron Lloyd

    2011-03-01

    There is debate concerning whether an aneurysmal ascending aorta should be replaced when associated with a dysfunctioning aortic valve that is to be replaced. To examine this issue, we divided the patients by type of aortic valve dysfunction-either aortic stenosis (AS) or pure aortic regurgitation (AR)-something not previously undertaken. Of 122 patients with ascending aortic aneurysm (unassociated with aortitis or acute dissection), the aortic valve was congenitally malformed (unicuspid or bicuspid) in 58 (98%) of the 59 AS patients, and in 38 (60%) of the 63 pure AR patients. Ascending aortic medial elastic fiber loss (EFL) (graded 0 to 4+) was zero or 1+ in 53 (90%) of the AS patients, in 20 (53%) of the 38 AR patients with bicuspid valves, and in all 12 AR patients with tricuspid valves unassociated with the Marfan syndrome. An unadjusted analysis showed that, among the 96 patients with congenitally malformed valves, the 38 AR patients had a significantly higher likelihood of 2+ to 4+ EFL than the 58 AS patients (crude odds ratio: 8.78; 95% confidence interval: 2.95, 28.13). These data strongly suggest that the type of aortic valve dysfunction-AS versus pure AR-is very helpful in predicting loss of aortic medial elastic fibers in patients with ascending aortic aneurysms and aortic valve disease.

  15. Tricuspid annuloplasty with the MC3 ring and septal plication technique.

    PubMed

    Isomura, Tadashi; Hirota, Masanori; Hoshino, Joji; Fukada, Yasuhisa; Kondo, Taichi; Takahashi, Yu

    2015-01-01

    Functional tricuspid regurgitation is caused by annular dilation mainly in the posterior annulus. However, ring annuloplasty does not always prevent the recurrence of tricuspid regurgitation due to dilation of the septal annulus. We developed a septal plication technique with a 3-dimensional MC3 ring. Between 2006 and 2011, 76 patients (male/female 30/46; mean age 68 ± 11 years) with functional tricuspid regurgitation received tricuspid ring annuloplasty. After placement of the annular sutures, the 3 commissural ring portions were fixed on the equivalent commissures to plicate the anterior and posterior annulus. The end of the septal ring portion was fixed at the optimal annular position to obtain minimal tricuspid regurgitation. All patients were followed-up for a mean of 47 ± 18 months; the longest duration was 79 months. Although there was no operative death, one patient died of sepsis during hospitalization (hospital mortality 1.3%). After implantation of the MC3 ring (mean size 31.0 ± 3.3 mm), additional edge-to-edge sutures were required for minor leakage in 5 (7%) patients. The degree of tricuspid regurgitation was significantly reduced at discharge (0.5 ± 0.6) and midterm (0.6 ± 0.6) compared to 2.5 ± 0.7 before the operation (p < 0.0001). The surgical durability of the MC3 ring was satisfactory at early and midterm follow-up, suggesting that correct plication of the septal annulus is effective for tricuspid ring annuloplasty with a 3-dimensional MC3 ring. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Investigation of membranous ventricular septal defect complicated with tricuspid regurgitation in ventricular septal defect occlusion

    PubMed Central

    LIU, SHU-PING; LI, LI; YAO, KE-CHUN; WANG, NA; WANG, JIAN-CHANG

    2013-01-01

    This study aimed to explore the mechanism of membranous ventricular septal defect complicated with tricuspid regurgitation and the significance of ventricular septal defect occlusion by echocardiography. A total of 43 patients with membranous ventricular septal defect complicated with tricuspid regurgitation were observed by echocardiography and the changes in length, area and volume of tricuspid regurgitation prior to and following ventricular septal defect occlusion were measured. There were four different mechanisms of membranous ventricular septal defect complicated with tricuspid regurgitation. The various indices of tricuspid regurgitation volume were significantly reduced following occlusion. Ventricular septal defect occlusion significantly reduces tricuspid regurgitation volume complicated with membranous ventricular septal defect and echocardiography is an ideal method to detect these changes. PMID:23404058

  17. Interventional Treatment of Severe Tricuspid Regurgitation: Early Clinical Experience in a Multicenter, Observational, First-in-Man Study.

    PubMed

    Lauten, Alexander; Figulla, Hans R; Unbehaun, Axel; Fam, Neil; Schofer, Joachim; Doenst, Torsten; Hausleiter, Joerg; Franz, Marcus; Jung, Christian; Dreger, Henryk; Leistner, David; Alushi, Brunilda; Stundl, Anja; Landmesser, Ulf; Falk, Volkmar; Stangl, Karl; Laule, Michael

    2018-02-01

    Transcatheter caval valve implantation is under evaluation as a treatment option for inoperable patients with severe tricuspid regurgitation (TR). The procedure involves the catheter-based implantation of bioprosthetic valves in the inferior vena cava and superior vena cava to treat symptoms associated with TR. This study is the first to evaluate the feasibility, safety, and efficacy of this interventional concept. Twenty-five patients (mean age, 73.9±7.6 years; women, 52.0%) with severe symptomatic TR despite optimal medical treatment deemed unsuitable for surgery were treated with caval valve implantation under a compassionate clinical use program. Technical feasibility defined as procedural success, hemodynamic effect defined as venous pressure reduction, and safety defined as periprocedural adverse events were evaluated, with clinical follow-up at discharge and up to 12 months. The functional impact was evaluated by assessment of New York Heart Association class at the time of hospital discharge. The total number of valves implanted in the caval position was 31. Patients were treated with single (inferior vena cava-only; n=19; 76.0%) or bicaval valve implantation (inferior vena cava+superior vena cava; n=6; 24.0%). Either balloon-expandable valves (Sapien XT/3: n=18; 72.0%) or self-expandable valves (TricValve: n=6; 24.0%; Directflow: n=1; 4.0%) were used. Procedural success was achieved in 96% (n=24). Early and late valve migration requiring surgical intervention occurred in 1 patient each. Thirty-day and in-hospital mortality were 8% (2 of 25) and 16% (4 of 25). Causes of in-hospital mortality included respiratory (n=1) or multiple organ failure (n=3) and were not linked to the procedure. Mean overall survival in the study cohort was 316±453 days (14-1540 days). Caval valve implantation for the treatment of severe TR and advanced right ventricular failure is associated with a high procedural success rate and seems safe and feasible in an excessive

  18. Clinical Implication of Transaortic Mitral Pannus Removal During Repeat Cardiac Surgery for Patients With Mechanical Mitral Valve.

    PubMed

    Park, Byungjoon; Sung, Kiick; Park, Pyo Won

    2018-01-25

    This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (P<0.001). No mechanical valve malfunction was apparent on last echocardiography. TMPR is a safe and effective procedure for patients with malfunction or stenosis of a mechanical mitral valve and may be considered an alternative approach in patients with pannus overgrowth in such valves.

  19. Tricuspid regurgitation by radionuclide angiography and contrast right ventriculography: a preliminary observation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumia, F.J.; Patil, A.; Germon, P.A.

    In a retrospective study correlating the degree of tricuspid regurgitation seen on first-pass radionuclide angiography with that seen on contrast right ventriculography in 51 patients, ten had no tricuspid regurgitation by contrast ventriculography, whereas by radionuclide angiography nine had no regurgitation and one had minimal regurgitation. Of eight patients with minimal tricuspid regurgitation by contrast ventriculography, five had minimal regurgitation by nuclide angiography and three had no regurgitation. Of the 11 patients with mild to moderate tricuspid regurgitation by contrast studies, ten had mild to moderate regurgitation and one had severe regurgitation by nuclide angiography. Of 22 patients with moderatemore » to severe tricuspid regurgitation by contrast studies, 15 had moderate to severe regurgitation and seven had mild to moderate regurgitation by nuclear angiography. In this preliminary study comparing radionuclide angiography with contrast right ventriculography, there were three false-negative and one false-positive nuclide angiograms, giving a sensitivity of 93% and a specificity of 90%.« less

  20. Spectrum of Aortic Valve Abnormalities Associated with Aortic Dilation Across Age Groups in Turner Syndrome

    PubMed Central

    Olivieri, Laura J.; Baba, Ridhwan Y.; Arai, Andrew E.; Bandettini, W. Patricia; Rosing, Douglas R.; Bakalov, Vladimir; Sachdev, Vandana; Bondy, Carolyn A.

    2014-01-01

    Background Congenital aortic valve fusion is associated with aortic dilation, aneurysm and rupture in girls and women with Turner syndrome (TS). Our objective was to characterize aortic valve structure in subjects with TS, and determine the prevalence of aortic dilation and valve dysfunction associated with different types of aortic valves. Methods and Results The aortic valve and thoracic aorta were characterized by cardiovascular magnetic resonance imaging in 208 subjects with TS in an IRB-approved natural history study. Echocardiography was used to measure peak velocities across the aortic valve, and the degree of aortic regurgitation. Four distinct valve morphologies were identified: tricuspid aortic valve (TAV) 64%(n=133), partially fused aortic valve (PF) 12%(n=25), bicuspid aortic valve (BAV) 23%(n=47), and unicuspid aortic valve (UAV) 1%(n=3). Age and body surface area (BSA) were similar in the 4 valve morphology groups. There was a significant trend, independent of age, towards larger BSA-indexed ascending aortic diameters (AADi) with increasing valve fusion. AADi were (mean +/− SD) 16.9 +/− 3.3 mm/m2, 18.3 +/− 3.3 mm/m2, and 19.8 +/− 3.9 mm/m2 (p<0.0001) for TAV, PF and BAV+UAV respectively. PF, BAV, and UAV were significantly associated with mild aortic regurgitation and elevated peak velocities across the aortic valve. Conclusions Aortic valve abnormalities in TS occur with a spectrum of severity, and are associated with aortic root dilation across age groups. Partial fusion of the aortic valve, traditionally regarded as an acquired valve problem, had an equal age distribution and was associated with an increased AADi. PMID:24084490

  1. Methodological inaccuracies in clinical aortic valve severity assessment: insights from computational fluid dynamic modeling of CT-derived aortic valve anatomy

    NASA Astrophysics Data System (ADS)

    Traeger, Brad; Srivatsa, Sanjay S.; Beussman, Kevin M.; Wang, Yechun; Suzen, Yildirim B.; Rybicki, Frank J.; Mazur, Wojciech; Miszalski-Jamka, Tomasz

    2016-04-01

    Aortic stenosis is the most common valvular heart disease. Assessing the contribution of the valve as a portion to total ventricular load is essential for the aging population. A CT scan for one patient was used to create one in vivo tricuspid aortic valve geometry and assessed with computational fluid dynamics (CFD). CFD simulated the pressure, velocity, and flow rate, which were used to assess the Gorlin formula and continuity equation, current clinical diagnostic standards. The results demonstrate an underestimation of the anatomic orifice area (AOA) by Gorlin formula and overestimation of AOA by the continuity equation, using peak velocities, as would be measured clinically by Doppler echocardiography. As a result, we suggest that the Gorlin formula is unable to achieve the intended estimation of AOA and largely underestimates AOA at the critical low-flow states present in heart failure. The disparity in the use of echocardiography with the continuity equation is due to the variation in velocity profile between the outflow tract and the valve orifice. Comparison of time-averaged orifice areas by Gorlin and continuity with instantaneous orifice areas by planimetry can mask the errors of these methods, which is a result of the assumption that the blood flow is inviscid.

  2. Surgical management of tricuspid atresia and anomalous left brachiocephalic vein.

    PubMed

    Koutlas, T C; Wernovsky, G; Slack, M C; Weinberg, P M; Spray, T L

    1998-06-01

    An anomalous left brachiocephalic vein is an uncommon systemic venous anomaly, which usually has no clinical significance. We describe a case of tricuspid atresia with such an anomalous left brachiocephalic vein. The presence of this unusual venous anomaly had a number of implications in the surgical management of the tricuspid atresia.

  3. Modified repair in patients with Ebstein's anomaly.

    PubMed

    Nagdyman, Nicole; Ewert, Peter; Komoda, Takeshi; Alexi-Meskisvili, Vladimir; Weng, Yuguo; Berger, Felix; Hetzer, Roland

    2010-05-01

    Since 1988, a modified repair technique has been used at the authors' institution to treat patients with Ebstein's anomaly. This technique restructures the valve mechanism at the level of the true tricuspid annulus by using the most mobile leaflet for valve closure, without plication of the atrialized chamber. A total of 19 patients had additional attachment of the anterior right ventricular wall to the interventricular septum (Sebening's stitch) and reconstruction of the tricuspid valve as a double-orifice valve. The long-term results of the study are presented. Between 1988 and 2008, tricuspid valve repair was performed in 50 patients with Ebstein's anomaly (33 females, 17 males; median age 22 years; range: 0.6 to 60 years), at the authors' institution. The median follow up was 68 months (range: 5 to 238) months. Details of the survival rate, reoperations, NYHA class, maximal VO2, right ventricular function (velocity-time integral pulmonary artery (VTI-PA)), and tricuspid valve insufficiency were documented. No patient deaths occurred during surgery; the early mortality was 7.1%, and late mortality 2.4%. Those patients who died were all aged > 50 years, and in NYHA class III or IV. No additional patient deaths have occurred since 2004. Four reoperations were necessary. Both, the NYHA class and tricuspid valve insufficiency were improved significantly (from 3.1 to 1.8; p < 0.001 and from 3.2 to 1.9; p < 0.001, respectively). The VTI-PA was increased significantly, with a stable heart rate (p = 0.01). No aneurysm of the right ventricle was observed. The long-term follow up demonstrated good clinical results in tricuspid repair, without plication of the right ventricle, even in cases where tricuspid valve replacement was discussed. Modifications seemed to support these results. Surgery in older patients with a progressive NYHA class seemed to carry a higher operative mortality.

  4. Equilibrium radionuclide gated angiography in patients with tricuspid regurgitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Handler, B.; Pavel, D.G.; Pietras, R.

    Equilibrium gated radionuclide angiography was performed in 2 control groups (15 patients with no organic heart disease and 24 patients with organic heart disease but without right- or left-sided valvular regurgitation) and in 9 patients with clinical tricuspid regurgitation. The regurgitant index, or ratio of left to right ventricular stroke counts, was significantly lower in patients with tricuspid regurgitation than in either control group. Time-activity variation over the liver was used to compute a hepatic expansion fraction which was significantly higher in patients with tricuspid regurgitation than in either control group. Fourier analysis of time-activity variation in each pixel wasmore » used to generate amplitude and phase images. Only pixels with values for amplitude at least 7% of the maximum in the image were retained in the final display. All patients with tricuspid regurgitation had greater than 100 pixels over the liver automatically retained by the computer. These pixels were of phase comparable to that of the right atrium and approximately 180 degrees out of phase with the right ventricle. In contrast, no patient with no organic heart disease and only 1 of 24 patients with organic heart disease had any pixels retained by the computer. In conclusion, patients with tricuspid regurgitation were characterized on equilibrium gated angiography by an abnormally low regurgitant index (7 of 9 patients) reflecting increased right ventricular stroke volume, increased hepatic expansion fraction (7 of 9 patients), and increased amplitude of count variation over the liver in phase with the right atrium (9 of 9 patients).« less

  5. Anterior Urethral Valve: Uncommon Association with Renal Duplicity.

    PubMed

    Salem, Amina Ben; Mazhoud, Ines; Laamiri, Rachida; Salem, Randa; Laajili, Hayet; Sahnoun, Lassaad; Hafsa, Chiraz

    2017-01-01

    Anterior urethral valves (AUVs) is an unusual cause of congenital obstruction of the male urethra, being 15-30 times less common than posterior urethral valves. We present a case of AUV diagnosed at 24th gestational week. Ultrasonography and fetal MRI revealed hydronephrotic kidneys with ureteral duplicity, a distended bladder and perineal cystic mass which confirmed dilated anterior urethra in a male fetus. Diagnosis was confirmed postnatally by voiding cystourethrogram and surgery.

  6. MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.

    PubMed

    Kistan, D; Booysen, M; Alexander, G; Madiba, T E

    2017-06-01

    Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients

  7. Risk model of prolonged intensive care unit stay in Chinese patients undergoing heart valve surgery.

    PubMed

    Wang, Chong; Zhang, Guan-xin; Zhang, Hao; Lu, Fang-lin; Li, Bai-ling; Xu, Ji-bin; Han, Lin; Xu, Zhi-yun

    2012-11-01

    The aim of this study was to develop a preoperative risk prediction model and an scorecard for prolonged intensive care unit length of stay (PrlICULOS) in adult patients undergoing heart valve surgery. This is a retrospective observational study of collected data on 3925 consecutive patients older than 18 years, who had undergone heart valve surgery between January 2000 and December 2010. Data were randomly split into a development dataset (n=2401) and a validation dataset (n=1524). A multivariate logistic regression analysis was undertaken using the development dataset to identify independent risk factors for PrlICULOS. Performance of the model was then assessed by observed and expected rates of PrlICULOS on the development and validation dataset. Model calibration and discriminatory ability were analysed by the Hosmer-Lemeshow goodness-of-fit statistic and the area under the receiver operating characteristic (ROC) curve, respectively. There were 491 patients that required PrlICULOS (12.5%). Preoperative independent predictors of PrlICULOS are shown with odds ratio as follows: (1) age, 1.4; (2) chronic obstructive pulmonary disease (COPD), 1.8; (3) atrial fibrillation, 1.4; (4) left bundle branch block, 2.7; (5) ejection fraction, 1.4; (6) left ventricle weight, 1.5; (7) New York Heart Association class III-IV, 1.8; (8) critical preoperative state, 2.0; (9) perivalvular leakage, 6.4; (10) tricuspid valve replacement, 3.8; (11) concurrent CABG, 2.8; and (12) concurrent other cardiac surgery, 1.8. The Hosmer-Lemeshow goodness-of-fit statistic was not statistically significant in both development and validation dataset (P=0.365 vs P=0.310). The ROC curve for the prediction of PrlICULOS in development and validation dataset was 0.717 and 0.700, respectively. We developed and validated a local risk prediction model for PrlICULOS after adult heart valve surgery. This model can be used to calculate patient-specific risk with an equivalent predicted risk at our centre in

  8. Computational Modeling of Blood Flow and Valve Dynamics in Hearts with Hypertrophic Cardiomyopathy

    NASA Astrophysics Data System (ADS)

    Zheng, Xudong; Mittal, Rajat; Abraham, Theodore; Pinheiro, Aurelio

    2010-11-01

    Hypertrophic Cardiomyopathy (HCM) is a cardiovascular disease manifested by the thickening of the ventricular wall and often leads to a partial obstruction to the blood flow out of the left ventricle. HCM is recognized as one of the most common causes of sudden cardiac death in athletes. In a heart with HCM, the hypertrophy usually narrows the blood flow pathway to the aorta and produces a low pressure zone between the mitral valve and the hypertrophy during systole. This low pressure can suck the mitral valve leaflet back and completely block the blood flow into the aorta. In the current study, a sharp interface immersed boundary method flow solver is employed to study the hemodynamics and valve dynamics inside a heart with HCM. The three-dimensional motion and configuration of the left ventricle including mitral valve leaflets and aortic valves are reconstructed based on echo-cardio data sets. The mechanisms of aortic obstruction associated with HCM are investigated. The long term objective of this study is to develop a computational tool to aid in the assessment and surgical management of HCM.

  9. [Status of aortic valve reconstruction and Ross operation in aortic valve diseases].

    PubMed

    Sievers, Hans H

    2002-08-01

    At first glance the aortic valve is a relative simple valve mechanism connecting the left ventricle and the ascending aorta. Detailed analysis of the different components of the aortic valve including the leaflets and sinuses revealed a complex motion of each part leading to a perfect durable valve mechanism at rest and during exercise. Theoretically, the reconstruction or imitation of these structures in patients with aortic valve disease should lead to optimal results. Prerequisite is the exact knowledge of the important functional characteristics of the aortic valve. The dynamic behavior of the aortic root closely harmonizing with the leaflets not only warrants stress minimizing and valve durability, but also optimizes coronary flow, left ventricular function and aortic impedance. The newly discovered contractile capacity of the leaflets and the root components are important for tuning the dynamics. Isolated reconstruction of the aortic valve such as decalcification, commissurotomy, plication of ring or leaflets of a tricuspid aortic valve and cusp extension are seldom indicated in contrast to the reconstruction of the bicuspid insufficient valve. Proper indication and skilled techniques lead to excellent hemodynamic and clinical intermediate-term result up to 7 years after reconstruction. Latest follow-up revealed a mean aortic insufficiency of 0.7, maximal pressure gradient of 11.4 +/- 8.5 mm Hg with zero hospital or late mortality, reoperation or thromboembolic events in 22 patients. The reconstructive techniques for aortic root aneurysm and/or type A dissection according to David or Yacoub have become routine procedures in the last 10 years. The hemodynamic and clinical results are excellent with low reoperation rate and very low risk of thromboembolism. Generally, a maximal diameter of the root of 5 cm is indicative for performing the operation. In patients with Marfan's syndrome the reconstruction should be advanced even with smaller diameters especially

  10. Increased pulmonary artery pressures during exercise are related to persistent tricuspid regurgitation after atrial septal defect closure.

    PubMed

    De Meester, Pieter; Van De Bruaene, Alexander; Herijgers, Paul; Voigt, Jens-Uwe; Vanhees, Luc; Budts, Werner

    2013-08-01

    Although closure of an atrial septal defect type secundum often normalizes right heart dimensions and pressures, mild tricuspid insufficiency might persist. This study aimed at (1) identification of determinants explaining the persistence of tricuspid insufficiency after atrial septal defect closure, and (2) evaluation of functional capacity of patients with persistent mild tricuspid insufficiency. Twenty-five consecutive patients (age 42+17 y) were included from the outpatient clinic of congenital heart disease at the University Hospitals of Leuven. All underwent transthoracic echocardiography, semi-supine bicycle stress echocardiography and cardio-pulmonary exercise testing. Six patients (24%) had mild tricuspid insufficiency (2/4) compared to 19 patients (76%) with no or minimal tricuspid insufficiency ( 1/4) as assessed by semi-quantitative colour Doppler echocardiography. Mann-Whitney U and Fisher's exact tests were performed where applicable. Patients with persistent mild tricuspid insufficiency were significantly older than those with no or minimal tricuspid insufficiency (P = 0.042). At rest, no differences in right heart configuration, mean pulmonary artery pressure or right ventricular function were found. At peak exercise, mean pulmonary artery pressure was significantly higher in patients with mild persistent tricuspid insufficiency (P = 0.026). Peak oxygen uptake was significantly lower in patients with mild persistent tricuspid insufficiency (P = 0.019). Mild tricuspid insufficiency after atrial septal defect repair occurs more frequently in older patients and in patients with higher mean pulmonary artery pressure at peak exercise. In patients with mild tricuspid insufficiency, functional capacity was more reduced. Mild tricuspid insufficiency could be a marker of subclinical persistent pressure load on the right ventricle.

  11. Incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery.

    PubMed

    LaPietra, Angelo; Santana, Orlando; Mihos, Christos G; DeBeer, Steven; Rosen, Gerald P; Lamas, Gervasio A; Lamelas, Joseph

    2014-07-01

    Minimally invasive valve surgery has been associated with increased cerebrovascular complications. Our objective was to evaluate the incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery. We retrospectively reviewed all the minimally invasive valve surgery performed at our institution from January 2009 to June 2012. The operative times, lengths of stay, postoperative complications, and mortality were analyzed. A total of 1501 consecutive patients were identified. The mean age was 73 ± 13 years, and 808 patients (54%) were male. Of the 1501 patients, 206 (13.7%) had a history of a cerebrovascular accident, and 225 (15%) had undergone previous heart surgery. The procedures performed were 617 isolated aortic valve replacements (41.1%), 658 isolated mitral valve operations (43.8%), 6 tricuspid valve repairs (0.4%), 216 double valve surgery (14.4%), and 4 triple valve surgery (0.3%). Femoral cannulation was used in 1359 patients (90.5%) and central cannulation in 142 (9.5%). In 1392 patients (92.7%), the aorta was clamped, and in 109 (7.3%), the surgery was performed with the heart fibrillating. The median aortic crossclamp and cardiopulmonary bypass times were 86 minutes (interquartile range [IQR], 70-107) minutes and 116 minutes (IQR, 96-143), respectively. The median intensive care unit length of stay was 47 hours (IQR, 29-74), and the median postoperative hospital length of stay was 7 days (IQR, 5-10). A total of 23 cerebrovascular accidents (1.53%) and 38 deaths (2.53%) had occurred at 30 days postoperatively. Minimally invasive valve surgery was associated with an acceptable stroke rate, regardless of the cannulation technique. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  12. An unusual cause of hemolysis in a patient with an aortic valved conduit replacement.

    PubMed

    Allman, Christine; Rajaratnam, Rohan; Kachwalla, Hashim; Hughes, Clifford F; Bannon, Paul; Leung, Dominic Y

    2003-02-01

    Hemolytic anemia is a well-known but uncommon complication in patients with prosthetic heart valves. It is most commonly a result of prosthetic valve dysfunction, periprosthetic valvular regurgitation, or both. We report a case of a 41-year-old man who had a previous aortic valve and root replacement for acute proximal aortic dissection, now presenting with hemolytic anemia. This was a result of flow obstruction at the distal anastomosis of the aortic conduit by the presence of multiple dissection flaps resulting in severe flow turbulence. Although the pathology was at the blind spot for transesophageal echocardiography, the dissection flaps, the flow turbulence, and the degree of obstruction were well-demonstrated by this technique after careful manipulation of the probe and a high index of suspicion.

  13. Nasal valve evaluation in the Mexican-Hispanic (mestizo) nose.

    PubMed

    Jasso-Ramírez, Elizabeth; Sánchez Y Béjar, Fernando; Arcaute Aizpuru, Fernando; Maulen Radován, Irene E; de la Garza Hesles, Héctor

    2018-04-01

    Our aim in this study was to determine the angle of the internal nasal valve in Mexican patients with the "mestizo nose" feature and without nasal obstructive symptoms. The work was prospective, comparative, and observational in nature and included patients >14 years of age who were seen in the Otolaryngology Department at the Los Angeles Lomas Hospital between April and May 2016. The angle of the internal nasal valve was measured in 30 patients without obstructive symptoms. Endoscopic examination was performed with a 0° endoscope framed with tape at a 13-mm distance from the endoscope's tip, and digital photographs of the internal nasal valve were taken. The measurement of the angle of the internal nasal valve was made in sexagesimal degrees using Golden Ratio v3.1 (2012) software. Statistical analysis was performed using Excel v15.13.3. The angles of the internal nasal valve of the patients were (mean ± standard deviation) 24.07 ± 4.8° for the right nasal cavity and 25.07 ± 5.0° for the left nasal cavity, wider than the angle reported in the normal Caucasian nose established in the literature. According to our results, the Mexican-Hispanic mestizo nose has a wider angle in the internal nasal valve than that considered normal in the literature (10°-15°). We believe it is necessary to undertake a second study and add an airflow resistance measurement with a rhinomanometry procedure so we can compare the results with those in the Caucasian population. © 2018 ARS-AAOA, LLC.

  14. Thrombolytic therapy for mitral valve thrombosis.

    PubMed

    Lin, T K; Tsai, L M; Chen, J H; Yang, Y J

    1997-05-01

    A 44-year-old man with a St. Jude mitral valve was admitted because of progressive pulmonary edema. He was diagnosed with prosthetic heart valve thrombosis (PHVT) based on the findings of "muffled" prosthetic valve clicks. Doppler echocardiographic evidence of severe mitral stenosis and transesophageal echocardiographic evidence of limited mitral valve motility. Because the patient hesitated to undergo our recommended surgical treatment, he was immediately treated with intravenous recombinant tissue plasminogen activator (100 mg over 3 h) followed by heparinization. Two hours after the thrombolytic therapy, the prosthetic valve clicks became clearly audible and his congestive symptoms were dramatically improved. Follow-up echocardiography no longer-showed significant mitral valve obstruction. A transient cerebral ischemic attack occurred at the end of thrombolytic therapy but there were no neurologic sequalae. The patient, on warfarin therapy, was well at follow-up 8 months after discharge. Surgical intervention has long been the standard therapy for patients with PHVT. Our case experience suggests that thrombolytic therapy may be considered as an effective alternative to surgical intervention for selected patients with PHVT. In this report, we also review the current literature regarding the indications, effectiveness and safety of thrombolytic therapy in PHVT.

  15. Three-dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification.

    PubMed

    El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A

    2018-01-23

    Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nagy, Edit, E-mail: edit.nagy@karolinska.se; Department of Cardiology, Karolinska University Hospital, Stockholm; Caidahl, Kenneth

    Highlights: Black-Right-Pointing-Pointer Oxidative stress has been implicated in the pathomechanism of calcific aortic valve stenosis. Black-Right-Pointing-Pointer We assessed the transcript levels for PARP-1 (poly(ADP-ribose) polymerase), acts as a DNA damage nick sensor in stenotic valves. Black-Right-Pointing-Pointer Early stage of diseased tricuspid valves exhibited higher mRNA levels for PARP-1 compared to bicuspid valves. Black-Right-Pointing-Pointer The mRNA levels for PARP-1 inversely correlated with the clinical stenosis severity in tricuspid valves. Black-Right-Pointing-Pointer Our data demonstrated that DNA damage pathways might be associated with stenosis severity only in tricuspid valves. -- Abstract: Oxidative stress may contribute to the hemodynamic progression of aortic valve stenosis,more » and is associated with activation of the nuclear enzyme poly(ADP-ribose) polymerase (PARP) 1. The aim of the present study was to assess the transcriptional profile and the topological distribution of PARP-1 in human aortic valves, and its relation to the stenosis severity. Human stenotic aortic valves were obtained from 46 patients undergoing aortic valve replacement surgery and used for mRNA extraction followed by quantitative real-time PCR to correlate the PARP-1 expression levels with the non invasive hemodynamic parameters quantifying the stenosis severity. Primary isolated valvular interstitial cells (VICs) were used to explore the effects of cytokines and leukotriene C{sub 4} (LTC{sub 4}) on valvular PARP-1 expression. The thickened areas of stenotic valves with tricuspid morphology expressed significantly higher levels of PARP-1 mRNA compared with the corresponding part of bicuspid valves (0.501 vs 0.243, P = 0.01). Furthermore, the quantitative gene expression levels of PARP-1 were inversely correlated with the aortic valve area (AVA) (r = -0.46, P = 0.0469) and AVA indexed for body surface area (BSA) (r = -0.498; P = 0.0298) only in tricuspid aortic

  17. Correlates of tricuspid regurgitation as determined by 3D echocardiography: pulmonary arterial pressure, ventricle geometry, annular dilatation, and papillary muscle displacement.

    PubMed

    Spinner, Erin M; Lerakis, Stamatios; Higginson, Jason; Pernetz, Maria; Howell, Sharon; Veledar, Emir; Yoganathan, Ajit P

    2012-01-01

    While it is understood that annular dilatation contributes to tricuspid regurgitation (TR), other factors are less clear. The geometry of the right ventricle (RV) and left ventricle (LV) may alter tricuspid annulus size and papillary muscle (PM) positions leading to TR. Three-dimensional echocardiographic images were obtained at Emory University Hospital using a GE Vivid 7 ultrasound system. End-diastolic area was used to classify ventricle geometry: control (n=21), isolated RV dilatation (n=17), isolated LV dilatation (n=13), and both RV and LV dilatation (n=13). GE EchoPAC was used to measure annulus area and position of the PM tips. Patients with RV dilatation had significant (P≤ 0.05) displacement of all PMs apically and the septal PM and posterior PM away from the center of the RV toward the LV. Patients with LV dilatation had significant (P≤0.05) apical displacement of the anterior PM. Pulmonary arterial pressure (r=0.66), annulus area (r=0.51), apical displacement of the anterior PM (r=0.26), posterior PM (r=0.49), and septal PM (r=0.40), lateral displacement of the septal PM (r=0.37) and posterior PM (r=0.40), and tenting area and height (r=0.54, 0.49), were significantly (P≤0.05) correlated to the grade of TR. Ventricle classification (r=0.46) and RV end-diastolic area (r=0.48) also were correlated with the grade of TR. A regression analysis found ventricle classification (P=0.001), pulmonary arterial pressure (P≤0.001) annulus area (P=0.027), and apical displacement of the anterior PM (P=0.061) to be associated with the grade of TR. Alterations in ventricular geometry can lead to TR by altering both tricuspid annulus size and PM position. Understanding these geometric interactions with the aim of correcting pathological alterations of the tricuspid valve apparatus may lead to more robust repairs.

  18. Atrioventricular valve repair in patients with functional single-ventricle physiology: impact of ventricular and valve function and morphology on survival and reintervention.

    PubMed

    Honjo, Osami; Atlin, Cori R; Mertens, Luc; Al-Radi, Osman O; Redington, Andrew N; Caldarone, Christopher A; Van Arsdell, Glen S

    2011-08-01

    This study was to determine whether atrioventricular valve repair modifies natural history of single-ventricle patients with atrioventricular valve insufficiency and to identify factors predicting survival and reintervention. Fifty-seven (13.5%) of 422 single-ventricle patients underwent atrioventricular valve repair. Valve morphology, regurgitation mechanism, and ventricular morphology and function were analyzed for effect on survival, transplant, and reintervention with multivariate logistic and Cox regression models. Comparative analysis used case-matched controls. Atrioventricular valve was tricuspid in 67% and common in 28%. Ventricular morphology was right in 83%. Regurgitation mechanisms were prolapse (n = 24, 46%), dysplasia (n = 18, 35%), annular dilatation (n = 8, 15%), and restriction or cleft (n = 2, 4%). Postrepair insufficiency was none or trivial in 14 (26%), mild in 33 (61%), and moderate in 7 (13%). Survival in repair group was lower than in matched controls (78.9% vs 92.7% at 1 year, 68.7% vs 90.6% at 3 years, P = .015). Patients with successful repair and normal ventricular function had equivalent survival to matched controls (P = .36). Independent predictors for death or transplant included increased indexed annular size (P = .05), increased cardiopulmonary bypass time (P = .04), and decreased postrepair ventricular function (P = .01). Ventricular dilation was a time-related factor for all events, including failed repair. Survival was lower in single-ventricle patients operated on for atrioventricular valve insufficiency than in case-matched controls. Patients with little postoperative residual regurgitation and preserved ventricular function had equivalent survival to controls. Lower grade ventricular function and ventricular dilation correlated with death and repair failure, suggesting that timing of intervention may affect outcome. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All

  19. The effect of pulmonary hypertension on ovine tricuspid annular dynamics.

    PubMed

    Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A

    2016-01-01

    Pulmonary hypertension (PHT) is associated with tricuspid annular dilatation, but the effect of acute increase of pulmonary pressure on three-dimensional (3D) tricuspid annular dynamics and shape is unknown. Better understanding of tricuspid annular dynamics may lead to improved and more durable surgical reparative techniques. In nine open-chest anaesthetized sheep nine sonomicrometry crystals were implanted on the right ventricle while on cardiopulmonary bypass. Additional nine crystals were implanted around the tricuspid annulus (TA) with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Two additional equidistant crystals were implanted between each commissure, creating three segments for every region. Pressure transducers were placed in the left ventricular (LV), right ventricular (RV) and right atrium. PHT was induced by acute pulmonary artery constriction with a pneumatic occluder. Sonomicrometry and echocardiographic data were collected before and after induction of PHT. TA area, regional and total perimeter, and 3D annular geometry were calculated from 3D crystal coordinates. Regional annular contraction was defined as the percentage difference between maximal and minimal region length during the cardiac cycle. PHT increased RV pressure from 31 ± 9 mmHg to 46 ± 13 mmHg (P = 0.001) and decreased left ventricular (LV) pressure from 111 ± 24 mmHg to 78 ± 36 mmHg (P = 0.018). There was no significant tricuspid regurgitation observed with PHT. During PHT, the TA area increased by 12 ± 13% from 641 ± 139 mm(2) to 721 ± 177 mm(2) (P = 0.037). The total perimeter increased from 103 ± 11 mm to 109 ± 13 mm (P = 0.02). All annular regions dilated significantly with PHT with 8 ± 10, 5 ± 5 and 5 ± 5% increase in anterior, posterior and septal annular length, respectively (P < 0.05). PHT reduced regional annular contraction in the anterior region only (17 ± 7 vs 14 ± 8%; P = 0.02). The TA had a complex 3

  20. Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.

    PubMed

    O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel

    2017-03-01

    Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.

  1. Lead dependent tricuspid dysfunction: Analysis of the mechanism and management in patients referred for transvenous lead extraction.

    PubMed

    Polewczyk, Anna; Kutarski, Andrzej; Tomaszewski, Andrzej; Brzozowski, Wojciech; Czajkowski, Marek; Polewczyk, Maciej; Janion, Marianna

    2013-01-01

    lead impingement of the leafl ets (21%). LDTD patients were treated with TLE and reimplantation of the lead to the right ventricle (87.5%) or to the cardiac vein (4.2%), or surgery procedure with epicardial lead placement following ineffective TLE (8.3%). The radiological and clinical effi cacy of TLE procedure was very high and comparable between the groups I and II (91.7% vs. 94.2%; p = 0.6 and 100% vs. 98.4%; p = 0.46, respectively). Repeated echocardiography showed reduced severity of tricuspid valve dysfunction in 62.5% of LDTD patients. The follow- -up interview confi rmed clinical improvement in 75% of patients (further improvement after cardiosurgery in 2 patients was observed). LDTD is a diagnostic and therapeutic challenge. The main reason for LDTD was abnormal leafl et coaptation caused by lead loop presence, or propping, or impingement the leafl ets by the lead. Probably, TLE with lead reimplantation is a safe and effective option in LDTD management. An alternative option is TLE with omitted tricuspid valve reimplantation. Cardiac surgery with epicardial lead placement should be reserved for patients with ineffective previous procedures.

  2. The JUPITER registry: 1-year results of transapical aortic valve implantation using a second-generation transcatheter heart valve in patients with aortic stenosis.

    PubMed

    Silaschi, Miriam; Treede, Hendrik; Rastan, Ardawan J; Baumbach, Hardy; Beyersdorf, Friedhelm; Kappert, Utz; Eichinger, Walter; Rüter, Florian; de Kroon, Thomas L; Lange, Rüdiger; Ensminger, Stephan; Wendler, Olaf

    2016-11-01

    Transcatheter aortic valve replacement (TAVR) is an established therapy for patients with aortic stenosis (AS) at high surgical risk. The JenaValve™ is a second-generation, self-expanding transcatheter heart valve (THV), implanted through transapical access (TA). During stent deployment, a specific 'clipping-mechanism' engages native aortic valve cusps for fixation. We present 1-year outcomes of the JUPITER registry, a post-market registry of the JenaValve for TA-TAVR. The JUPITER registry is a prospective, multicentre, uncontrolled and observational European study to evaluate the long-term safety and effectiveness of the Conformité Européenne-marked JenaValve THV. A total of 180 patients with AS were enrolled between 2012 and 2014. End-points were adjudicated in accordance with the valve academic research consortium document no. 1 definitions. The mean age was 80.4 ± 5.9 years and the mean logistic European system for cardiac operative risk evaluation I 21.2 ± 14.7%. The procedure was successful in 95.0% (171/180), implantation of a second THV (valve-in-valve) was performed in 2.2% (4/180) and conversion to surgical aortic valve replacement (SAVR) was necessary in 2.8% (5/180). No annular rupture or coronary ostia obstruction occurred. Two patients required SAVR after the day of index procedure (1.1%). All-cause mortality at 30 days was 11.1% (20/180), being cardiovascular in 7.2% (13/180). A major stroke occurred in 1.1% (2/180) at 30 days, no additional major strokes were observed during 1 year. All-cause mortality after 30 days was 13.1% (21/160) and combined efficacy at 1 year was 80.8% (122/151). At 1-year follow-up, no patient presented with more than moderate paravalvular leakage, while 2 patients (3.2%) showed moderate, 12 (19.0%) mild and 49 (82.4%) trace/none paravalvular regurgitation. In a high-risk cohort of patients undergoing TA-TAVR for AS, the use of the JenaValve THV is safe and effective. In patients at higher risk for coronary ostia

  3. Reoperation for non-structural valvular dysfunction caused by pannus ingrowth in aortic valve prosthesis.

    PubMed

    Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk

    2013-07-01

    The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p < 0.001), and the mean pressure gradient was decreased to 11.9 +/- 1.9 mmHg (p < 0.001). Non-structural valvular dysfunction caused by pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.

  4. Evidence of subannular and left ventricular morphological differences in patients with bicuspid versus tricuspid aortic valve stenosis: magnetic resonance imaging-based analysis.

    PubMed

    Disha, Kushtrim; Dubslaff, Georg; Rouman, Mina; Fey, Beatrix; Borger, Michael A; Barker, Alex J; Kuntze, Thomas; Girdauskas, Evaldas

    2017-03-01

    Prospective analysis of left ventricular (LV) morphological/functional parameters in patients with bicuspid versus tricuspid aortic valve (TAV) stenosis undergoing aortic valve replacement (AVR) surgery. A total of 190 consecutive patients with BAV ( n  = 154) and TAV stenosis ( n  = 36) (mean age 61 ± 8 years, 65% male) underwent AVR ± concomitant aortic surgery from January 2012 through May 2015. All patients underwent preoperative cardiac magnetic resonance imaging in order to evaluate: (i) left ventricular outflow tract (LVOT) dimensions, (ii) length of anterior mitral leaflet (AML), (iii) end-systolic and end-diastolic LV wall thickness, (iv) LV area, (v) LV end-systolic and end-diastolic diameters (LVESD, LVEDD), (vi) LV end-diastolic and end-systolic volumes (LVEDV, LVESV) and (vii) maximal diameter of aortic root. These parameters were compared between the two study groups. The LVOT diameter was significantly larger in BAV patients (21.7 ± 3 mm in BAV vs 18.9 ± 3 mm in TAV, P  < 0.001). Moreover, BAV patients had significantly longer AML (24 ± 3 mm in BAV vs 22 ± 4 mm in TAV, P  = 0.009). LVEDV and LVESV were significantly larger in BAV patients (LVEDV: 164.9 ± 68.4 ml in BAV groups vs 126.5 ± 53.1 ml in TAV group, P  = 0.037; LVESV: 82.1 ± 57.9 ml in BAV group vs 52.9 ± 25.7 ml in TAV group, P  = 0.008). A strong linear correlation was found between LVOT diameter and aortic annulus diameter in BAV patients ( r  = 0.7, P  < 0.001), whereas significantly weaker correlation was observed in TAV patients ( r  = 0.5, P  = 0.006, z  = 1.65, P  = 0.04). Presence of BAV morphology was independently associated with larger LVOT diameters (OR 9.0, 95% CI 1.0-81.3, P  = 0.04). We found relevant differences in LV morphological/functional parameters between BAV and TAV stenosis patients. Further investigations are warranted in order to determine the

  5. The effect of acute mechanical left ventricular unloading on ovine tricuspid annular size and geometry.

    PubMed

    Malinowski, Marcin; Wilton, Penny; Khaghani, Asghar; Brown, Michael; Langholz, David; Hooker, Victoria; Eberhart, Lenora; Hooker, Robert L; Timek, Tomasz A

    2016-09-01

    Left ventricular assist device (LVAD) implantation may alter right ventricular shape and function and lead to tricuspid regurgitation. This in turn has been reported to be a determinant of right ventricular (RV) failure after LVAD implantation, but the effect of mechanical left ventricular (LV) unloading on the tricuspid annulus is unknown. The aim of the study was to provide insight into the effect of LVAD support on tricuspid annular geometry and dynamics that may help to optimize LV unloading with the least deleterious effect on the right-sided geometry. In seven open-chest anaesthetized sheep, nine sonomicrometry crystals were implanted on the right ventricle. Additional nine crystals were implanted around the tricuspid annulus, with one crystal at each commissure defining three separate annular regions: anterior, posterior and septal. Left ventricular unloading was achieved by connecting a cannula in the left atrium and the aorta to a continuous-flow pump. The pump was used for 15 min at a full flow of 3.8 ± 0.3 l/min. Epicardial echocardiography was used to assess the degree of tricuspid insufficiency. Haemodynamic, echocardiographic and sonomicrometry data were collected before and during full unloading. Tricuspid annular area, and the regional and total perimeter were calculated from crystal coordinates, while 3D annular geometry was expressed as the orthogonal distance of each annular crystal to the least squares plane of all annular crystals. There was no significant tricuspid regurgitation observed either before or during LV unloading. Right ventricular free wall to septum diameter increased significantly at end-diastole during unloading from 23.6 ± 5.8 to 26.3 ± 6.5 mm (P = 0.009), but the right ventricular volume, tricuspid annular area and total perimeter did not change from baseline. However, the septal part of the annulus significantly decreased its maximal length (38.6 ± 8.1 to 37.9 ± 8.2 mm, P = 0.03). Annular contraction was not altered. The

  6. Dual-source CT imaging to plan transcatheter aortic valve replacement: accuracy for diagnosis of obstructive coronary artery disease.

    PubMed

    Harris, Brett S; De Cecco, Carlo N; Schoepf, U Joseph; Steinberg, Daniel H; Bayer, Richard R; Krazinski, Aleksander W; Dyer, Kevin T; Sandhu, Monique K; Zile, Michael R; Meinel, Felix G

    2015-04-01

    To assess the accuracy of computed tomographic (CT) examinations performed for the purpose of transcatheter aortic valve replacement (TAVR) planning to diagnose obstructive coronary artery disease (CAD). With institutional review board approval, waivers of informed consent, and in compliance with HIPAA, 100 consecutive TAVR candidates (61 men, mean age 79.6 years ± 9.9) who underwent both TAVR planning CT (with a dual-source CT system) and coronary catheter (CC) angiographic imaging were retrospectively analyzed. At both modalities, the presence of stenosis in the native coronary arteries was assessed. Additionally, all coronary bypass grafts were rated as patent or occluded. With CC angiographic imaging as the reference standard, the accuracy of CT for lesion detection on a per-vessel and per-patient basis was calculated. The accuracy of CT for the assessment of graft patency was also analyzed. For per-vessel and per-patient analysis for the detection of stenosis that was 50% or more in the native coronary arteries, CT imaging had, respectively, 94.4% and 98.6% sensitivity, 68.4% and 55.6% specificity, 94.7% and 93.8% negative predictive value (NPV), and 67.0% and 85.7% positive predictive value. Per-patient sensitivity of stenosis 50% or greater with CT for greater than 70% stenosis at CC angiographic imaging was 100%. All 12 vessels in which percutaneous coronary intervention was performed were correctly identified as demonstrating stenosis 50% or greater with CT. There was agreement between CT and CC angiographic imaging regarding graft patency in 114 of 115 grafts identified with CC angiographic imaging. TAVR planning CT has high sensitivity and NPV in excluding obstructive CAD. An additional preprocedural CC angiographic examination may not be required in TAVR candidates with a CT examination that does not show obstructive CAD. © RSNA, 2014 Online supplemental material is available for this article.

  7. Anterior urethral valves without diverticulae: a report of two cases and a review of the literature.

    PubMed

    Singh, Dig Vijay; Taneja, Rajesh

    2014-05-01

    Two unusual cases of anterior urethral valves (AUV) without diverticulae are presented. The first case is a male child born with prenatal diagnosis of bilateral hydronephrosis. On cystoscopy, iris-like diaphragm valves were encountered about 3 mm distal to the skeletal sphincter. In the second case, an 18-month-old male child was investigated for recurrent febrile urinary tract infections and obstructed urinary symptoms. Cystoscopy confirmed the presence of slit-like valves 5 mm distal to the skeletal sphincter. Fulguration of the AUVs was performed in both cases. It may be worthwhile to review all cases of anterior urethral obstruction collectively and re-categorize them appropriately to include the unusual AUVs without diverticulum in that classification. © 2013 Japanese Teratology Society.

  8. EDUCATIONAL SERIES IN CONGENITAL HEART DISEASE: Congenital left-sided heart obstruction

    PubMed Central

    Carr, Michelle; Curtis, Stephanie; Marek, Jan

    2018-01-01

    Congenital obstruction of the left ventricular outflow tract remains a significant problem and multilevel obstruction can often coexist. Obstruction can take several morphological forms and may involve the subvalvar, valvar or supravalvar portion of the aortic valve complex. Congenital valvar stenosis presenting in the neonatal period represents a spectrum of disorders ranging from the hypoplastic left heart syndrome to almost normal hearts. Treatment options vary dependent on the severity of the left ventricular outflow tract obstruction (LVOTO) and the variable degree of left ventricular hypoplasia as well as the associated lesions such as arch hypoplasia and coarctation. PMID:29681546

  9. Trans-apical aortic valve implantation in patients with severe calcification of the ascending aorta.

    PubMed

    Buz, Semih; Pasic, Miralem; Unbehaun, Axel; Drews, Thorsten; Dreysse, Stephan; Kukucka, Marian; Mladenow, Alexander; Hetzer, Roland

    2011-08-01

    In patients with calcification of the ascending aorta, postoperative stroke and mortality rates remain high after conventional aortic valve replacement, but the results of trans-apical aortic valve implantation in these patients are not known. We evaluate the outcome of trans-apical aortic valve implantation in patients with severely calcified ascending aorta in a single center with expanded procedural experience. Between April 2008 and July 2010, 258 patients underwent trans-apical aortic valve implantation using Edwards Sapien valve. By computed tomography (CT) scan, we identified 46 (18%) patients with severe calcification of the ascending aorta (16 with porcelain aorta and 30 with severe, but not complete, calcification). Of 46 patients (mean age 77 ± 10 years, range 63-90 years; EuroSCORE (European System for Cardiac Operative Risk Evaluation) 45 ± 22%; STS (Society of Thoracic Surgeons) score 23 ± 13) with calcified aorta, 15 received 23-mm valves and 31 patients 26-mm valves. Primary valve implantation was successful in 44 patients and a second valve was implanted (valve-in-valve) in two. Six patients underwent concomitant interventions (three elective percutaneous coronary intervention (PCI), one off-pump coronary artery bypass (OPCAB), one tricuspid valve reconstruction, and one left-ventricular (LV) aneurysmectomy). The final procedural results showed valve incompetence (trace or grade 1) in 17 (37%) patients and paravalvular leak in 15 (32.6%) (trace in 10 and grade 1 in five). There was no 30-day mortality. Postoperatively, cranial CT showed new cerebral ischemia areas in three patients (6.2%), but only one patient (2.1%) experienced postoperative neurological deficit (temporary aphasia). Survival at 6 and 12 months was 88% and 85.2%, respectively. Trans-apical aortic valve implantation can be performed safely in patients with aortic valve stenosis and severe calcification of the ascending aorta. Copyright © 2010 European Association for Cardio

  10. Cardiopulmonary bypass after severe blunt hepatic injury: management of multi-system blunt trauma in an adolescent.

    PubMed

    Streit, Stephanie; Kavarana, Minoo; Scheurer, Mark A; Cina, Robert A

    2013-06-01

    A 16-year-old adolescent male sustained combined injuries to the tricuspid valve and liver. This injury is exceptional due to the mechanism and the circumstances in which it took place: a flying pumpkin thrown from a sport utility vehicle. An echocardiogram demonstrated a flail chordal apparatus associated with the posterior leaflet of the tricuspid valve, creating substrate for severe tricuspid regurgitation with preserved right heart function. He was treated with non-operative management for the liver injury; he remained hemodynamically stable and was discharged home. He underwent successful repair of the tricuspid valve 17 days following the initial injury necessitating systemic anticoagulation and was discharged home two days later. The patient recovered fully without residual valvular pathology or hepatic sequelae. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Unusual Giant Right Atrium in Rheumatic Mitral Stenosis and Tricuspid Insufficiency

    PubMed Central

    Anzouan-Kacou, Jean Baptiste; Konin, Christophe; Coulibaly, Iklo; N'guetta, Roland; Adoubi, Anicet; Soya, Esaïe; Boka, Bénédicte

    2011-01-01

    Dilation and hypertrophy of the atria occur in patients with valvular heart disease especially in mitral regurgitation, mitral stenosis or tricuspid abnormalities. In sub-saharan Africa, rheumatic fever is still the leading cause of valvular heart disease. We report a case of an unusual giant right atrium in context of rheumatic stenosis and severe tricuspid regurgitation in a 58-year-old woman. PMID:24826228

  12. Tachycardia-Induced Right Heart Failure and Severe Tricuspid Regurgitation That Improved with Medication.

    PubMed

    Yang, Young Ae; Yang, Dong Heon; Kim, Hong Nyun; Kwon, Sang Hoon; Jang, Se Young; Bae, Myung Hwan; Lee, Jang Hoon; Chae, Shung Chull

    2015-12-01

    Secondary tricuspid regurgitation (TR) primarily develops due to left heart failure or primary pulmonary diseases. Tricuspid annular dilation, which is commonly caused by right ventricular volume and pressure overload followed by right ventricle dilation, is believed to be the main mechanism underlying secondary TR. It is reported that once the tricuspid annulus is dilated, its size cannot spontaneously return to normal, and it may continue to dilate. These reports also suggest the use of an aggressive surgical approach for secondary TR. In the present report, we describe a case of tachycardia-induced severe TR that was completely resolved without the need for surgery.

  13. A Comparative Result of Ventriculoperitoneal Shunt, Focusing Mainly on Gravity-Assisted Valve and Programmable Valve

    PubMed Central

    Lee, Won-Chul; Choe, Il-Seung; Park, Sung-Choon; Ha, Young-Soo; Lee, Kyu Chang

    2010-01-01

    Objective Despite rapid evolution of shunt devices, the complication rates remain high. The most common causes are turning from obstruction, infection, and overdrainage into mainly underdrainage. We investigated the incidence of complications in a consecutive series of hydrocephalic patients. Methods From January 2002 to December 2009, 111 patients underwent ventriculoperitoneal (VP) shunting at our hospital. We documented shunt failures and complications according to valve type, primary disease, and number of revisions. Results Overall shunt survival time was 268 weeks. Mean survival time of gravity-assisted valve (GAV) was 222 weeks versus 286 weeks for other shunts. Survival time of programmable valves (264 weeks) was longer than that of pressure-controlled valves (186 weeks). The most common cause for shunt revision was underdrainage (13 valves). The revision rate due to underdrainage in patients with GAV (7 of 10 patients) was higher than that for other valve types. Of 7 patients requiring revision for GAV underdrainage, 6 patients were bedridden. The overall infection rate was 3.6%, which was lower than reported series. Seven patients demonstrating overdrainage had cranial defects when operations were performed (41%), and overdrainage was improved in 5 patients after cranioplasty. Conclusion Although none of the differences was statistically significant, some of the observations were especially notable. If a candidate for VP shunting is bedridden, GAV may not be indicated because it could lead to underdrainage. Careful procedure and perioperative management can reduce infection rate. Cranioplasty performed prior to VP shunting may be beneficial. PMID:21082054

  14. Unusual mechanism of tricuspid regurgitation in ventricular septal defect.

    PubMed

    Desai, Ravi V; Seghatol-Eslami, Frank; Nabavizadeh, Fatemeh; Lloyd, Steven G

    2011-02-01

    A 37-year-old woman was diagnosed to have a small ventricular septal defect (VSD) with high velocity tricuspid regurgitation (TR) that was attributed to atrio-VSD (Gerbode). Cardiac MR revealed a small subaortic VSD in the membranous portion of the interventricular septum. The atrioventricular portion was intact. Cardiac MR clearly showed flow jet through the VSD, impinging on the anterior tricuspid leaflet during systole, and bouncing back into the right atrium as TR. This ricochet mechanism of TR in VSD may be misinterpreted as Gerbode defect or as evidence of pulmonary hypertension. © 2011, Wiley Periodicals, Inc.

  15. [Major tricuspid insufficiency and absence of systolic valvular coaptation. Echocardiographic study. Apropos of 6 cases].

    PubMed

    Roudaut, R; Héraudeau, A; Gosse, P; Aouizerate, E; Dequecker, J L; Dallocchio, M

    1986-09-01

    In a retrospective series of 960 cases of tricuspid regurgitation studied by two-dimensional echocardiography 6 patients presented a systolic defect of valvular coaptation. The origin of this defect varied: one case was due to carcinoid, two to rheumatic cardiopathy, two to papyraceous right ventricle and one to sclerodermia associated with pulmonary arterial hypertension. The mechanism of the lacking coaptation varies according to the etiology: valvular retraction in carcinoid cardiopathy, right-ventricle dilatation, dilatation of the tricuspid ring and altered kinetics of the right ventricle in the other cases. Changed contractility of the right ventricle is the only element allowing to distinguish tricuspid regurgitation with and without a coaptation defect. Clinically this abnormality always points to an advanced stage of severe tricuspid regurgitation.

  16. Evaluation of the safety and efficacy of transcatheter aortic valve implantation in patients with a severe stenotic bicuspid aortic valve in a Chinese population*

    PubMed Central

    Liu, Xian-bao; Jiang, Ju-bo; Zhou, Qi-jing; Pu, Zhao-xia; He, Wei; Dong, Ai-qiang; Feng, Yan; Jiang, Jun; Sun, Yong; Xiang, Mei-xiang; He, Yu-xin; Fan, You-qi; Dong, Liang; Wang, Jian-an

    2015-01-01

    Objective: The purpose of this study is to evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) in patients with a severe stenotic bicuspid aortic valve (BAV) in a Chinese population. While several groups have reported the feasibility, efficacy, and safety of TAVI for patients with a BAV, worldwide experience of the technique is still limited, especially in China. Methods: From March 2013 to November 2014, high surgical risk or inoperable patients with symptomatic severe aortic stenosis (AS) who had undergone TAVI at our institution were selected for inclusion in our study. Results were compared between a BAV group and a tricuspid aortic valve (TAV) group. Results: Forty patients were included in this study, 15 (37.5%) of whom were identified as having a BAV. In the BAV group, the aortic valve area was smaller ((0.47±0.13) vs. (0.59±0.14) cm2), the ascending aortic diameter was larger ((40.4±4.4) vs. (36.4±4.3) mm), and the concomitant aortic regurgitation was lower. No significant differences were found between the groups in the other baseline characteristics. No differences were observed either in the choice of access or valve size. The procedural success achieved in this study was 100%. There were no differences between groups in device success (86.7% vs. 88.0%), 30-d mortality (6.7% vs. 8.0%), or 30-d combined end point (13.3% vs. 12.0%). The incidences of new pacemaker implantation, paravalvular regurgitation and other complications, recovery of left ventricle ejection fraction and heart function were similar in both groups. Conclusions: Patients with a severely stenotic BAV can be treated with TAVI, and their condition after treatment should be similar to that of people with a TAV. PMID:25743122

  17. Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management.

    PubMed

    Ostrowski, Stanisław; Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard

    2015-09-01

    Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications. The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Precise and modern diagnostic methods

  18. Ascending aorta dilatation rates in patients with tricuspid and bicuspid aortic stenosis: the COFRASA/GENERAC study.

    PubMed

    Kerneis, Caroline; Pasi, Nicoletta; Arangalage, Dimitri; Nguyen, Virginia; Mathieu, Tiffany; Verdonk, Constance; Codogno, Isabelle; Ou, Phalla; Duval, Xavier; Tubiana, Sarah; Cimadevilla, Claire; Vahanian, Alec; Messika-Zeitoun, And David

    2017-07-25

    Ascending aorta (AA) dilatation is common in aortic valve stenosis (AS) but data regarding AA progression, its determinants and impact of valve anatomy [bicuspid (BAV), or tricuspid (TAV)] are scarce. Asymptomatic AS patients enrolled in a prospective cohort (COFRASA/GENERAC) with at least 2 years of follow-up were considered in the present analysis. A transthoracic echocardiography (TTE) and a computed tomography (CT) scan were performed at inclusion and yearly thereafter. We enrolled 195 patients [mean gradient 22 ± 11 mmHg, 42 BAV patients (22%)]. Mean aorta diameters assessed using TTE were 35 ± 4 and 36 ± 5 mm at the sinuses of Valsalva and tubular level, respectively. Ascending aorta diameter was >40 mm in 29% of patients (24% in TAV vs. 52% in BAV, P < 0.01). Determinants of AA diameters were age, sex, BSA, and BAV, but not AS severity. After a mean follow-up of 3.8 ± 1.5years, AA enlargement rate assessed using TTE was +0.18 ± 0.34 mm/year and +0.36 ± 0.54 mm/year at the Valsalva and tubular level, respectively. Determinants of the progression of AA size were smaller AA diameter (P < 0.01) but not baseline AS severity or valve anatomy (all P > 0.05). Only four patients presented an AA progression ≥2 mm/year. Correlations between TTE and CT scan were excellent (all r >0.74) and similar results were obtained using CT. During follow-up, two BAV patients underwent a combined AA surgery; no surgery was primarily performed for AA aneurysm and no dissection was observed. In this prospective cohort of AS patients determinants of AA diameters were age, sex, BSA, and valve anatomy but not AS severity. AA progression rates were low and not influenced by AS severity or valve anatomy. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  19. The long non-coding HOTAIR is modulated by cyclic stretch and WNT/β-CATENIN in human aortic valve cells and is a novel repressor of calcification genes.

    PubMed

    Carrion, Katrina; Dyo, Jeffrey; Patel, Vishal; Sasik, Roman; Mohamed, Salah A; Hardiman, Gary; Nigam, Vishal

    2014-01-01

    Aortic valve calcification is a significant and serious clinical problem for which there are no effective medical treatments. Individuals born with bicuspid aortic valves, 1-2% of the population, are at the highest risk of developing aortic valve calcification. Aortic valve calcification involves increased expression of calcification and inflammatory genes. Bicuspid aortic valve leaflets experience increased biomechanical strain as compared to normal tricuspid aortic valves. The molecular pathogenesis involved in the calcification of BAVs are not well understood, especially the molecular response to mechanical stretch. HOTAIR is a long non-coding RNA (lncRNA) that has been implicated with cancer but has not been studied in cardiac disease. We have found that HOTAIR levels are decreased in BAVs and in human aortic interstitial cells (AVICs) exposed to cyclic stretch. Reducing HOTAIR levels via siRNA in AVICs results in increased expression of calcification genes. Our data suggest that β-catenin is a stretch responsive signaling pathway that represses HOTAIR. This is the first report demonstrating that HOTAIR is mechanoresponsive and repressed by WNT β-catenin signaling. These findings provide novel evidence that HOTAIR is involved in aortic valve calcification.

  20. Quadricuspid Aortic Valve: A Comprehensive Review

    PubMed Central

    Yuan, Shi-Min

    2016-01-01

    Quadricuspid aortic valve (QAV) is a rare congenital heart disease. The functional status of QAV is predominantly a pure aortic regurgitation. Clinical manifestations of patients with a QAV depend on the functional status of the QAV and the associated disorders. Significant valvular regurgitation and (or) stenosis is often present with subsequent operation performed at the fifth to sixth decade of life. The functional status of QAV is predominantly regurgitant; whereas pure stenotic QAV can be as few as in only 0.7% of the patients. QAV is usually an isolated anomaly, but other congenital heart defects can be present in 18-32% of the patients. About one-fifth of them require a surgical operation. Tricuspidalization is a preferred technique for QAV repair. As not all the patients with a QAV necessarily warrant a surgical operation, decision-making in patient selection and surgical procedure of choice are crucial. Antibiotic prophylaxis against infective endocarditis is necessary in the QAV patients with unequal-sized cusps. PMID:28076624

  1. Atrioventricular and intraventricular block after transcatheter aortic valve implantation.

    PubMed

    Lee, Jane J; Goldschlager, Nora; Mahadevan, Vaikom S

    2018-06-24

    Aortic stenosis is the most common valvular heart disease in industrialized countries and the most common cause of left ventricular outflow tract (LVOT) obstruction. Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement for intermediate to high-risk surgical candidates with symptomatic severe aortic stenosis. Conduction system abnormalities, including atrioventricular (AV) and intraventricular (IV) block, are the most common complication of TAVR. In this review, we aim to explore the anatomical issues relevant to atrioventricular block, the relevant clinical and procedural aspects, and the management and long-term implications of AV and IV block.

  2. Poor clinical performance of the Wessex porcine heart valve bioprosthesis at nine years' follow up.

    PubMed Central

    Hurlé, A.; Nistal, J. F.; Revuelta, J. M.

    1997-01-01

    OBJECTIVE: To assess the long term performance of the Wessex porcine bioprostheses implanted in a consecutive series of patients. DESIGN: A retrospective case series. PATIENTS: Between January 1985 and July 1991, 184 Wessex bioprostheses (78 mitral, 102 aortic, and 4 tricuspid) were implanted in 150 patients. The patients were 55% (83/150) male and 45% (67/150) female; mean age was 60 (SD 10) years. RESULTS: Hospital mortality was 9.3% (14/150). Total follow up was 696 patient-years (mean 4.7 years per patient). Linearised rates (events per 100 patient-years (SEM) for postoperative complications for patients with isolated mitral valve replacement, isolated aortic valve replacement, and multiple valve replacement were, respectively: late mortality: 4.7 (1.6), 3.3 (0.9), and 4.9 (1.9); thromboembolism: 5.8 (1.8), 3.0 (0.9), and 2.8 (1.4); valve thrombosis: 1.0 (0.7), 0.3 (0.3), and 0.7 (0.7); structural failure: 5.8 (1.7), 1.9 (0.7), and 7.1 (2.2). Actuarial freedom from complications at nine years (70% confidence interval) was: late mortality: 61 (9)%, 57 (13)%, and 59 (12)%; thromboembolism and valve thrombosis: 71 (9)%, 79 (6)%, and 81 (8)%; structural failure: 33 (14)%, 50 (16)%, and 12 (14)%; all valve related morbidity/mortality: 31 (10)%, 21 (11)%, and 7 (9)%. Stent fractures appeared in 11 of 17 explanted prostheses; actuarial freedom from stent fracture at nine years was 66 (12)%. CONCLUSIONS: The Wessex bioprosthesis is associated with high thrombogenicity, early structural dysfunction, and a high valve related morbidity/mortality which justifies very close follow up of patients fitted with them. Images PMID:9155609

  3. Value of echo-Doppler derived pulmonary vascular resistance, net-atrioventricular compliance and tricuspid annular velocity in determining exercise capacity in patients with mitral stenosis.

    PubMed

    Choi, Eui-Young; Shim, Jaemin; Kim, Sung-Ai; Shim, Chi Young; Yoon, Se-Jung; Kang, Seok-Min; Choi, Donghoon; Ha, Jong-Won; Rim, Se-Joong; Jang, Yangsoo; Chung, Namsik

    2007-11-01

    The present study sought to determine if echo-Doppler-derived pulmonary vascular resistance (PVR echo), net-atrioventricular compliance (Cn) and tricuspid peak systolic annular velocity (Sa), as parameters of right ventricular function, have value in predicting exercise capacity in patients with mitral stenosis (MS). Thirty-two patients with moderate or severe MS without left ventricular systolic dysfunction were studied. After comprehensive echo-Doppler measurements, including PVR echo, tricuspid Sa and left-sided Cn, supine bicycle exercise echo and concomitant respiratory gas analysis were performed. Measurements during 5 cardiac cycles representing the mean heart rate were averaged. Increment of resting PVR(echo) (r=-0.416, p=0.018) and decrement of resting Sa (r=0.433, p=0.013) and Cn (r=0.469, p=0.007) were significantly associated with decrease in %VO(2) peak. The predictive accuracy for %VO2 peak could increase by combining these parameters as Sa/PVR echo (r=0.500, p=0.004) or Cn. (Sa/PVR echo) (r=0.572, p=0.001) independent of mitral valve area, mean diastolic pressure gradients or presence of atrial fibrillation. Measurement of PVR echo, Cn and Sa might provide important information about the exercise capacity of patients with MS.

  4. Validity of cardiac output measurement by the thermodilution method in the presence of acute tricuspid regurgitation.

    PubMed

    Boerboom, L E; Kinney, T E; Olinger, G N; Hoffmann, R G

    1993-10-01

    Evaluation of patients with acute tricuspid insufficiency may include assessment of cardiac output by the thermodilution method. The accuracy of estimates of thermodilution-derived cardiac output in the presence of tricuspid insufficiency has been questioned. This study was designed to determine the validity of the thermodilution technique in a canine model of acute reversible tricuspid insufficiency. Cardiac output as measured by thermodilution and electromagnetic flowmeter was compared at two grades of regurgitation. The relationship between these two methods (thermodilution/electromagnetic) changed significantly from a regression slope of 1.01 +/- 0.18 (mean +/- standard deviation) during control conditions to a slope of 0.86 +/- 0.23 (p < 0.02) during severe regurgitation. No significant change was observed between control and mild regurgitation or between the initial control value and a control measurement repeated after tricuspid insufficiency was reversed at the termination of the study. This study shows that in a canine model of severe acute tricuspid regurgitation the thermodilution method underestimates cardiac output by an amount that is proportional to the level of cardiac output and to the grade of regurgitation.

  5. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    NASA Technical Reports Server (NTRS)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  6. An overview of the literature on congenital lower urinary tract obstruction and introduction to the PLUTO trial: percutaneous shunting in lower urinary tract obstruction.

    PubMed

    Morris, R Katie; Kilby, Mark D

    2009-02-01

    Congenital lower urinary tract obstruction (LUTO) comprises a heterogeneous group of pathologies causing obstruction to the urethra, the most common being posterior urethral valves. Such pathology is often associated with high perinatal mortality and varying degrees of perinatal and infant morbidity. A high proportion of LUTO may be visualised during routine second trimester (and first trimester) ultrasound giving rise to the possibility of determining individual fetal prognosis and treatments such as vesico-amniotic shunting, with a view to altering pathogenesis. The aims of the percutaneous shunting in low urinary tract obstruction (PLUTO) trial are to determine the effectiveness of these treatments and accuracy of the investigations with the primary outcome measures being perinatal mortality and postnatal renal function.

  7. Short-course thrombolysis as the first line of therapy for cardiac valve thrombosis.

    PubMed

    Manteiga, R; Carlos Souto, J; Altès, A; Mateo, J; Arís, A; Dominguez, J M; Borrás, X; Carreras, F; Fontcuberta, J

    1998-04-01

    To retrospectively evaluate the clinical and echocardiographic criteria of thrombolytic therapy for mechanical heart valve thrombosis. Nineteen consecutive patients with 22 instances of prosthetic heart valve thrombosis (14 mitral, 2 aortic, 3 tricuspid, and 3 pulmonary) were treated with short-course thrombolytic therapy as first option of treatment in absence of contraindications. The thrombolytic therapy protocol consisted of streptokinase (1,500,000 IU in 90 minutes) (n = 18) in one (n = 7) or two (n = 11) cycles or recombinant tissue-type plasminogen activator (100 mg in 90 minutes) (n = 4). Overall success was seen in 82%, immediate complete success in 59%, and partial success in 23%. Six patients without total response to thrombolytic therapy underwent surgery, and pannus was observed in 83%. Six patients showed complications: allergy, stroke, transient ischemic attack, coronary embolism, minor bleeding, and one death. At diagnosis, 10 patients evidenced atrial thrombus by transesophageal echocardiography, 3 of whom experienced peripheral embolism during thrombolysis. Four episodes of rethrombosis were observed (16%). The survivorship was 84% with a mean follow-up of 42.6 months. A short-course of thrombolytic therapy may be considered first-line therapy for prosthetic heart valve thrombosis. The risk of peripheral embolism may be evaluated for the presence of atrial thrombus by transesophageal echocardiography at diagnosis.

  8. Artificial aortic valve dysfunction due to pannus and thrombus – different methods of cardiac surgical management

    PubMed Central

    Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard

    2015-01-01

    Introduction Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. Case study 1 The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs’ surface was found. A biological aortic prosthesis was reimplanted without complications. Case study 2 The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored

  9. Morphology of the atrioventricular valves and related intraventricular structures in the wild pig (Sus scrofa).

    PubMed

    Ateş, Sevinç; Karakurum, Emine; Takcı, Lutfi; Başak, Feyza; Kürtül, İbrahim

    2017-06-14

    Morphology of the atrioventricular valves and the intraventricular related structures were observed and the findings were compared broadly to the literature, in the 7 hearts of the wild pigs (Sus scrofa) by applying macroscopic and microscopic techniques. In all hearts examinated, the tricuspid and mitral valves were precise, composing three and two cusps resepectively. The papillary muscles observed in mammalian heart in general were found in both the ventricles, additionaly there were small unnamed papillary muscles in the left ventricle of the three samples. The septomarginal trabecula and false chords were present in the right ventricles, microscopically possessing myocardial fibers, connective tissue and purkinje cells while the false chords were located in all the left ventricles but the septomarginal trabecula was found in the three samples only. Both the connective tissue and purkinje cells were present in these two structures but the myocardial fibers. Presence of the myocardial fibers in the right ventricle may have an effect on the ventricle geometry.

  10. Should high risk patients with concomitant severe aortic stenosis and mitral valve disease undergo double valve surgery in the TAVR era?

    PubMed

    Yu, Pey-Jen; Mattia, Allan; Cassiere, Hugh A; Esposito, Rick; Manetta, Frank; Kohn, Nina; Hartman, Alan R

    2017-12-29

    Significant mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The aim of this study is to determine if surgical correction of both aortic and mitral valves in high risk patients with concomitant valvular disease would offer patients better outcomes than TAVR alone. A retrospective analysis of 43 high-risk patients who underwent concomitant surgical aortic valve replacement and mitral valve surgery from 2008 to 2012 was performed. Immediate and long term survival were assessed. There were 43 high-risk patients with severe aortic stenosis undergoing concomitant surgical aortic valve replacement and mitral valve surgery. The average age was 80 ± 6 years old. Nineteen (44%) patients had prior cardiac surgery, 15 (34.9%) patients had chronic obstructive lung disease, and 39 (91%) patients were in congestive heart failure. The mean Society of Thoracic Surgeons Predicted Risk of Mortality for isolated surgical aortic valve replacement for the cohort was 10.1% ± 6.4%. Five patients (11.6%) died during the index admission and/or within thirty days of surgery. Mortality rate was 25% at six months, 35% at 1 year and 45% at 2 years. There was no correlation between individual preoperative risk factors and mortality. High-risk patients with severe aortic stenosis and mitral valve disease undergoing concomitant surgical aortic valve replacement and mitral valve surgery may have similar long term survival as that described for such patients undergoing TAVR. Surgical correction of double valvular disease in this patient population may not confer mortality benefit compared to TAVR alone.

  11. Cross sectional echocardiographic feature in carcinoid heart disease. A mechanism for tricuspid regurgitation in this syndrome.

    PubMed

    Davies, M K; Lowry, P J; Littler, W A

    1984-03-01

    In a patient with severe tricuspid regurgitation and mild pulmonary stenosis due to carcinoid heart disease cross sectional echocardiography showed nodular thickening and coaptation of the tricuspid leaflets at the beginning of systole. The leaflets were, however, seen to be increasingly pulled apart as right ventricular systole proceeded. This finding, which is probably due to traction on the leaflets by the thickened chordae tendineae, is therefore a mechanism of valvular incompetence, perhaps accounting for the particularly severe tricuspid regurgitation seen in carcinoid heart disease.

  12. The protective arm of the renin-angiotensin system may counteract the intense inflammatory process in fetuses with posterior urethral valves.

    PubMed

    Rocha, Natalia P; Bastos, Fernando M; Vieira, Érica L M; Prestes, Thiago R R; Silveira, Katia D da; Teixeira, Mauro M; Simões E Silva, Ana Cristina

    2018-03-11

    Posterior urethral valve is the most common lower urinary tract obstruction in male children. A high percentage of patients with posterior urethral valve evolve to end-stage renal disease. Previous studies showed that cytokines, chemokines, and components of the renin-angiotensin system contribute to the renal damage in obstructive uropathies. The authors recently found that urine samples from fetuses with posterior urethral valve have increased levels of inflammatory molecules. The aim of this study was to measure renin-angiotensin system molecules and to investigate their correlation with previously detected inflammatory markers in the same urine samples of fetuses with posterior urethral valve. Urine samples from 24 fetuses with posterior urethral valve were collected and compared to those from 22 healthy male newborns at the same gestational age (controls). Renin-angiotensin system components levels were measured by enzyme-linked immunosorbent assay. Fetuses with posterior urethral valve presented increased urinary levels of angiotensin (Ang) I, Ang-(1-7) and angiotensin-converting enzyme 2 in comparison with controls. ACE levels were significantly reduced and Ang II levels were similar in fetuses with posterior urethral valve in comparison with controls. Increased urinary levels of angiotensin-converting enzyme 2 and of Ang-(1-7) in fetuses with posterior urethral valve could represent a regulatory response to the intense inflammatory process triggered by posterior urethral valve. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  13. Very long-term results (more than 20 years) of valve repair with carpentier's techniques in nonrheumatic mitral valve insufficiency.

    PubMed

    Braunberger, E; Deloche, A; Berrebi, A; Abdallah, F; Celestin, J A; Meimoun, P; Chatellier, G; Chauvaud, S; Fabiani, J N; Carpentier, A

    2001-09-18

    Mitral valve repair is considered the gold standard in surgery of degenerative mitral valve insufficiency (MVI), but the long-term results (>20 years) are unknown. We reviewed the first 162 consecutive patients who underwent mitral valve repair between 1970 and 1984 for MVI due to nonrheumatic disease. The cause of MVI was degenerative in 146 patients (90%) and bacterial endocarditis in 16 patients (10%). MVI was isolated or, in 18 cases, associated with tricuspid insufficiency. The mean age of the 162 patients (104 men and 58 women) was 56+/-10 years (age range 22 to 77 years). New York Heart Association functional class was I, II, III, and IV in 2%, 39%, 52%, and 7% of patients, respectively. The mean cardiothoracic ratio was 0.58+/-0.07 (0.4 to 0.8), and 72 (45%) patients had atrial fibrillation. Valve analysis showed that the main mechanism of MVI was type II Carpentier's functional classification in 152 patients. The leaflet prolapse involved the posterior leaflet in 93 patients, the anterior leaflet in 28 patients, and both leaflets in 31 patients. Surgical technique included a Carpentier's ring annuloplasty in all cases, a valve resection in 126 patients, and shortening or transposition of chordae in 49 patients. During the first postoperative month, there were 3 deaths (1.9%) and 3 reoperations (2 valve replacements and 1 repeat repair [1.9%]). Six patients were lost to follow-up. The remaining 151 patients with mitral valve repair were followed during a median of 17 years (range 1 to 29 years; 2273 patient-years). The 20-year Kaplan-Meier survival rate was 48% (95% CI 40% to 57%), which is similar to the survival rate for a normal population with the same age structure. The 20-year rates were 19.3% (95% CI 11% to 27%) for cardiac death and 26% (95% CI 17% to 35%) for cardiac morbidity/mortality (including death from a cardiac cause, stroke, and reoperation). During the 20 years of follow-up, 7 patients were underwent surgery at 3, 7, 7, 8, 8, 10, or 12

  14. Routine Papillary Muscle Realignment and Septal Myectomy for Obstructive Hypertrophic Cardiomyopathy.

    PubMed

    Song, Howard K; Turner, Jason; Macfie, Rebekah; Kumar, Suwen; Mannello, Meghan J; Smith, Danielle; Bhamidipati, Castigliano; Raman, Jaishankar; Tibayan, Frederick; Heitner, Stephen B

    2018-05-10

    Septal myectomy has been the mainstay of the surgical treatment of obstructive hypertrophic cardiomyopathy (HCM), however recently there is growing appreciation for associated mitral valve abnormalities that contribute to left ventricular outflow tract (LVOT) obstruction. In this study, we describe our experience with combined papillary muscle realignment (PMR) and septal myectomy for the treatment of obstructive HCM. We identified 44 patients undergoing surgery for obstructive HCM whose anatomy was amenable to combined PMR and septal myectomy at our institution over a 20-month period. All patients underwent resting and stress echocardiography pre- and postoperatively. Demographic, clinical, and imaging data were prospectively collected in a cardiac surgery database. Patient age ranged broadly, with mean age of 54 years (range 18-76). Preoperatively, 70% of patients were NYHA Class III or IV, the mean stress LVOT gradient was 144 mmHg, and severe mitral regurgitation (MR) with stress was seen in 81% . Additional procedures included division of myocardial bands (50%) and chordae (43%) and resection of accessory papillary muscles (25%). Following the procedure, mean resting and stress gradients were reduced to normal (12 and 27 mmHg, respectively, p < 0.0001). No patient had severe MR and only 3 (6.8%) had moderate MR (p < 0.0001).Mean length of stay was 6 days and there were no mortalities. Septal myectomy combined with PMR is a safe, highly effective, and reproducible procedure that reliably relieves LVOT obstruction and corrects MR without the need for mitral valve repair or replacement. Copyright © 2018. Published by Elsevier Inc.

  15. [Isolated mitral valve insufficiency in comparison with mitral-tricuspid insufficiency: various mechanisms of compensating for the defect and functional status of the myocardium].

    PubMed

    Petrovskiĭ, P F; Torbina, A M; Klemborskiĭ, A A

    1988-09-01

    A combined analysis of ventricular contractility and intracardiac hemodynamic compensatory mechanisms was carried out, on the basis of angiocardiographic findings, in 37 patients with rheumatic mitral incompetence. Atrial fibrillation aggravates essentially the defect's hemodynamics, while added tricuspid incompetence is accompanied by a certain off-loading in the lesser circulation network. A grossly perversed phasic structure of intramyocardial stress was noted, apparently being a compensatory mechanism. Reduced specific coronary flow and diastolic perfusion gradient in intact coronary arteries are shown to be causes of clinical angina.

  16. Endogenous Reference Genes for Gene Expression Studies on Bicuspid Aortic Valve Associated Aortopathy in Humans.

    PubMed

    Harrison, Oliver J; Moorjani, Narain; Torrens, Christopher; Ohri, Sunil K; Cagampang, Felino R

    2016-01-01

    Bicuspid aortic valve (BAV) disease is the most common congenital cardiac abnormality and predisposes patients to life-threatening aortic complications including aortic aneurysm. Quantitative real-time reverse transcription PCR (qRT-PCR) is one of the most commonly used methods to investigate underlying molecular mechanisms involved in aortopathy. The accuracy of the gene expression data is dependent on normalization by appropriate housekeeping (HK) genes, whose expression should remain constant regardless of aortic valve morphology, aortic diameter and other factors associated with aortopathy. Here, we identified an appropriate set of HK genes to be used as endogenous reference for quantifying gene expression in ascending aortic tissue using a spin column-based RNA extraction method. Ascending aortic biopsies were collected intra-operatively from patients undergoing aortic valve and/or ascending aortic surgery. These patients had BAV or tricuspid aortic valve (TAV), and the aortas were either dilated (≥4.5cm) or undilated. The cohort had an even distribution of gender, valve disease and hypertension. The expression stability of 12 reference genes were investigated (ATP5B, ACTB, B2M, CYC1, EIF4A2, GAPDH, SDHA, RPL13A, TOP1, UBC, YWHAZ, and 18S) using geNorm software. The most stable HK genes were found to be GAPDH, UBC and ACTB. Both GAPDH and UBC demonstrated relative stability regardless of valve morphology, aortic diameter, gender and age. The expression of B2M and SDHA were found to be the least stable HK genes. We propose the use of GAPDH, UBC and ACTB as reference genes for gene expression studies of BAV aortopathy using ascending aortic tissue.

  17. Incremental benefit of 3D transesophageal echocardiography: a case of a mass overlying a prosthetic mitral valve.

    PubMed

    Tauras, James M; Zhang, Zhihang; Taub, Cynthia C

    2011-05-01

    A young woman with a mechanical mitral valve and prosthetic mitral stenosis underwent multiple imaging modalities (including transthoracic ECHO, fluoroscopy, and two-dimensional transesophageal ECHO) to determine the cause of her stenosis. Only three-dimensional transesophageal echocardiography demonstrated the full size and extent of an obstructing mass on the strut and sewing ring of the prosthetic mitral valve. © 2011, Wiley Periodicals, Inc.

  18. Urodynamic changes in patients with anterior urethral valves: before and after endoscopic valve ablation.

    PubMed

    Kajbafzadeh, Abdol-Mohammad; Payabvash, Seyedmehdi; Karimian, Golnar

    2007-08-01

    To retrospectively review a series of children with anterior urethral valves (AUV), with emphasis on patterns of urodynamic change and long-term outcome of endoscopic treatment. We reviewed the medical records of eight patients who had undergone thorough radiological and urodynamic exams before and after treatment. The diagnosis of AUV was based on radiological imaging and confirmed by urethrocystoscopy. The valves were ablated through either transurethral fulguration or resection. The upper urinary tracts were studied by renal scan and ultrasonography before and after the procedure. Bladder function was assessed urodynamically 3 months after surgery. Uroflowmetry was performed as soon as the children were toilet trained. Endoscopic ablation of AUV was successful in all cases and no surgical complications occurred. The initial symptoms resolved in all boys. VUR disappeared in two out of three patients, and five children had bladder trabeculation that was resolved after surgery. The final outcome was successful in seven patients (88%). The major urodynamic dysfunction was bladder hypercontractility that resolved following valve ablation. The mean maximum voiding detrusor pressure (P(detmax)) decreased from 213.2+/-17.9 cmH(2)O to 80.7+/-9.9 cmH(2)O, 6 months after treatment (P<0.001). None of the patients had low-compliant bladder, detrusor instability or myogenic failure. The voiding pattern in all toilet-trained patients was staccato and of an interrupted shape prior to surgery, but changed to a normal bell-shaped voiding pattern following valve ablation. AUV should be considered in the differential diagnosis of patients presenting with infravesical obstruction. We recommend endoscopic valve ablation as the treatment of choice.

  19. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    PubMed

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  20. Single coronary artery with bicuspid aortic valve stenosis and aneurysm of the ascending aorta: report of a case.

    PubMed

    Ishida, Narihiro; Shimabukuro, Katsuya; Matsuno, Yukihiro; Ogura, Hiroki; Takemura, Hirofumi

    2014-03-01

    A 73-year-old man with a severely stenosed bicuspid valve and an aneurysm of the ascending aorta underwent valve and aortic surgery. Preoperative imaging revealed a single coronary artery arising from the right side of the sinus of Valsalva and a branch that perfused into the left side of the heart to pass through the front of the pulmonary artery. We replaced the aortic valve and ascending aorta, painstakingly avoiding damage to the coronary artery and obstruction of the sole coronary ostium.

  1. Outcome in 55 dogs with pulmonic stenosis that did not undergo balloon valvuloplasty or surgery.

    PubMed

    Francis, A J; Johnson, M J S; Culshaw, G C; Corcoran, B M; Martin, M W S; French, A T

    2011-06-01

    To determine the outcome, independent predictors of cardiac death, and the Doppler-derived pressure gradient cut-off for predicting cardiac death in dogs with pulmonic stenosis, with or without tricuspid regurgitation, that do not undergo balloon valvuloplasty or valve surgery. Review of medical records of two UK referral centres between July 1997 and October 2008 for all cases of pulmonic stenosis that had no balloon valvuloplasty or valve surgery. Inclusion criteria included a diagnosis of pulmonic stenosis; spectral Doppler pulmonic velocity greater than 1·6 m/s; characteristic valve leaflet morphological abnormalities. Exclusion criteria included concurrent significant cardiac defects, including tricuspid dysplasia. Dogs with tricuspid regurgitation were included. Dogs were classified according to Doppler-derived pressure gradients into mild, moderate or severe pulmonic stenosis categories. Presence of tricuspid regurgitation and severe stenosis were independent predictors of cardiac death. A pulmonic pressure gradient of more than 60 mmHg was associated with 86% sensitivity, and 71% specificity of predicting cardiac death. There is an increased probability of cardiac death in those cases which have a pulmonary pressure gradient greater than 60 mmHg and tricuspid regurgitation, though the effect of severity of tricuspid regurgitation on outcome was not measurable because of small sample sizes. These animals might benefit from intervention. © 2011 British Small Animal Veterinary Association.

  2. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall be...

  3. Multidetector computed tomography sizing of aortic annulus prior to transcatheter aortic valve replacement (TAVR): Variability and impact of observer experience.

    PubMed

    Le Couteulx, S; Caudron, J; Dubourg, B; Cauchois, G; Dupré, M; Michelin, P; Durand, E; Eltchaninoff, H; Dacher, J-N

    2018-05-01

    To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality. MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64-93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated. Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer. Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve. Copyright © 2017. Published by Elsevier Masson SAS.

  4. Mild mitral and tricuspid regurgitation secondary to pericardial constriction.

    PubMed

    Mittal, S R

    2014-06-01

    A 26 years female presented with pericardial effusion. On follow up she developed pericardial constriction with new appearance of mild mitral and tricuspid regurgitation without any other pathology. Fibrosis along posterior atrioventricular groove could be responsible for regurgitation.

  5. Presence of ´isolated´ tricuspid regurgitation should prompt the suspicion of heart failure with preserved ejection fraction

    PubMed Central

    Mascherbauer, Julia; Kammerlander, Andreas A.; Zotter-Tufaro, Caroline; Aschauer, Stefan; Duca, Franz; Dalos, Daniel; Winkler, Susanne; Schneider, Matthias; Bergler-Klein, Jutta; Bonderman, Diana

    2017-01-01

    Background Diastolic dysfunction of the left ventricle is common but frequently under-diagnosed. Particularly in advanced stages affected patients may present with significant functional tricuspid regurgitation (TR) as the most prominent sign on echocardiography. The underlying left ventricular pathology may eventually be missed and symptoms of heart failure are attributed to TR, with respective therapeutic consequences. The aim of the present study was to determine prevalence and mechanisms underlying TR evolution in heart failure with preserved ejection fraction (HFpEF). Methods and results Consecutive HFpEF patients were enrolled in this prospective, observational study. Confirmatory diagnostic tests including echocardiography and invasive hemodynamic assessments were performed. Of the 175 patients registered between 2010 and 2014, 51% had significant (moderate or severe) TR without structural abnormalities of the tricuspid valve. Significant hemodynamic differences between patients with and without relevant TR were encountered. These included elevated pulmonary vascular resistance (p = 0.038), reduced pulmonary arterial compliance (PAC, p = 0.005), and elevated left ventricular filling pressures (p = 0.039) in the TR group. Multivariable binary logistic regression analysis revealed diastolic pulmonary artery pressure (p = 0.029) and PAC (p = 0.048) as independent determinants of TR. Patients were followed for 18.1±14.1 months, during which 32% had a cardiac event. While TR was associated with outcome in the univariable analysis, it failed to predict event-free survival in the multivariable model. Conclusions The presence of ´isolated´ functional TR should prompt the suspicion of HFpEF. Our data show that significant TR is a marker of advanced HFpEF but neither an isolated entity nor independently associated with event-free survival. PMID:28199339

  6. A technique of snaring method for fitting a prosthetic valve into the annulus.

    PubMed

    Nagasaka, Shigeo; Kawata, Tetsuji; Matsuta, Masahiro; Taniguchi, Shigeki

    2005-01-01

    Tourniquetting technique to fit a prosthetic valve (PV) into the annulus in valve replacement surgery has been previously reported. We modified the previously reported method and designed a simpler tying technique. We performed 11 aortic (AVR: including four cases for calcified aortic stenosis (AS) with a small annulus and one cases for infective endocarditis with intramuscular abscess cavity), eight mitral valve replacements (MVR), and one tricuspid valve replacement (TVR: for corrected transposition of the great arteries). A PV was implanted using 2-0 polyester mattress sutures with a pledget. Each of the two tourniquets held a suture at the bottom of the annulus and at the opposite position to fit a PV. The sutures between each snare were tied down from the bottom to the top. In MVR, after seating of a PV with two tourniquets, we could make sure that no native tissue of any preserved mitral apparatus disturbed PV leaflet motion. In calcific AS, a PV had a good fitting into the annulus because of tourniquets applied to unseated part during tying sutures. In AVR for infective endocarditis, mattress sutures supported by a Teflon pledget were placed to close the abscess cavity. After snaring on one of these sutures, we tied down the sutures, ensuring that they did not cut through the friable tissues. In TVR, we found that native leaflets interfered with PV motion after seating down the prosthesis and those leaflets were resected before tying down the sutures. Postoperative transesophageal echocardiography showed no paravalvular leakage in any patients and excellent PV functions.

  7. Clinical context and mechanism of functional tricuspid regurgitation in patients with and without pulmonary hypertension.

    PubMed

    Topilsky, Yan; Khanna, Amber; Le Tourneau, Thierry; Park, Soon; Michelena, Hector; Suri, Rakesh; Mahoney, Douglas W; Enriquez-Sarano, Maurice

    2012-05-01

    Functional tricuspid regurgitation (FTR) with structurally normal valve is of poorly defined mechanisms. Prevalence and clinical context of idiopathic FTR (Id-FTR) (without overt TR cause) are unknown. To investigate prevalence, clinical context, and mechanisms specific to FTR types, Id-FTR versus pulmonary hypertension-related (PHTN-FTR, systolic pulmonary pressure ≥50 mm Hg), we analyzed 1161 patients with prospectively quantified TR. Id-FTR (prevalence 12%) was associated with aging and atrial fibrillation. For mechanistic purposes, we measured valvular and right ventricular (RV) remodeling in 141 Id-FTR matched to 140 PHTN-FTR and to 99 controls with trivial TR for age, sex, atrial fibrillation, and ejection fraction. PHTN-FTR and Id-FTR were also matched for TR effective-regurgitant-orifice (ERO). Id-FTR valvular alterations (versus controls) were largest annular area (3.53±0.6 versus 2.74±0.4 cm(2), P<0.0001) and lowest valvular/annular coverage ratio (1.06±0.1 versus 1.45±0.2, P<0.0001) but normal valve tenting height. PHTN-FTR had mild annular enlargement but excessive valve tenting height (0.8±0.3 versus 0.35±0.1 cm, P<0.0001). Valvular changes were linked to specific RV changes, largest basal dilatation, and normal length (RV conical deformation) in Id-FTR versus longest RV with elliptical/spherical deformation in PHTN-FTR. With increasing FTR severity (ERO ≥40 mm(2)), changes specific to each FTR type were accentuated, and RV function (index of myocardial performance) was consistently reduced. Id-FTR is frequent, linked to aging and atrial fibrillation, can be severe, and is of unique mechanism. In Id-FTR, excess annular and RV-basal enlargement exhausts valvular/annular coverage reserve, and RV conical deformation does not cause notable valvular tenting. Conversely, PHTN-FTR is determined by valvular tethering with tenting linked to RV elongation and elliptical/spherical deformation. These specific FTR-mechanisms may be important in

  8. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves

    PubMed Central

    Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico

    2017-01-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078

  9. NT-proBNP and exercise capacity in adult patients with congenital heart disease and a prosthetic valve: a multicentre PROSTAVA study.

    PubMed

    Schoonbeek, R C; Pieper, P G; van Slooten, Y J; Freling, H G; Sieswerda, G T; van Dijk, A P J; Jongbloed, M R M; Post, M C; Bouma, B J; Berger, R M F; Ebels, T; van Melle, J P

    2016-11-01

    N-terminal B‑type natriuretic peptide (NT-proBNP) is an important biomarker for the detection of heart failure. Adults with congenital heart disease (ACHD) and a prosthetic heart valve are at risk for heart failure. This study aimed to determine the value of NT-proBNP in ACHD patients with a prosthetic valve and investigate its relationship with cardiac function and exercise capacity. In this multi-centre cross-sectional observational study, data regarding medical history, echocardiography, exercise testing (VO 2 peak) and laboratory blood evaluation (including NT-proBNP) were collected in ACHD patients with a single prosthetic valve (either homografts, heterografts or mechanical valves). A total of 306 ACHD patients with pulmonary valve replacement (PVR, n = 139), aortic valve replacement (n = 141), mitral valve replacement (n = 21) or tricuspid valve replacement (n = 5) were investigated. The majority of patients (77 %) were in NYHA class I or II. Elevated NT-proBNP levels (cut-off ≥125 pg/ml) were found in 50 % of the patients, with the highest levels in patients with mitral valve replacements. In this study population, NT-proBNP levels were associated with gender (p = 0.029) and VO 2 max (p < 0.001). In PVR patients, NT-proBNP levels were associated with lower VO 2 peak, also after adjustment for age, gender and age at valve replacement in a multivariate model (p = 0.015). In patients with ACHD and a prosthetic valve, elevated NT-proBNP levels are frequently observed despite preserved NYHA class. In PVR patients, a higher NT-proBNP level was associated with a lower VO 2 peak. These results may be of importance in the ongoing discussion about the timing of valve replacement in patients with CHD.

  10. Functional valve assessment: the emerging role of cardiovascular magnetic resonance.

    PubMed

    Shah, Dipan J

    2010-01-01

    The prevalence of valvular heart disease is increasing along with the life span of the population. In assessing individuals with valve disease, echocardiography is the primary imaging modality used by clinicians both for initial assessment and for longitudinal evaluation. Information regarding valve morphology and function, cardiac chamber size, wall thickness, ventricular function, and estimates of pulmonary artery pressures can be readily obtained and integrated to formulate an assessment of valve disease severity. In some instances, body habitus or the presence of coexisting lung disease may result in suboptimal acoustic windows on echocardiography, which may lead to technically difficult studies. Additionally, in some patients, information from clinical history and physical examination or other diagnostic tests may be discordant with echocardiographic findings. In these instances, there is a significant clinical role for cardiovascular magnetic resonance (CMR). The diagnostic capabilities of CMR have increased substantially over the past 20 years due to hardware and software advances. Today, CMR has a number of unique advantages over other imaging modalities - primarily, it provides a view of the entire heart without limitations from inadequate imaging windows or body habitus. Furthermore, CMR can obtain imaging data in any imaging plane prescribed by the scan operator, which makes it ideal for accurate investigation of all cardiac valves - aortic, mitral, pulmonic, and tricuspid. In addition, CMR for valve assessment is noninvasive, free of ionizing radiation, and in most instances does not require contrast administration. Since a comprehensive review of the role of CMR in all valve lesions is beyond the scope of this article, we will focus on the most common valvular indication for performance of clinical CMR techniques and an overview of selected validation and reproducibility studies. The objectives of a comprehensive CMR study for evaluating mitral

  11. Initial experience with xenograft bioconduit for the treatment of complex prosthetic valve endocarditis.

    PubMed

    Roubelakis, Apostolos; Karangelis, Dimos; Sadeque, Syed; Yanagawa, Bobby; Modi, Amit; Barlow, Clifford W; Livesey, Steven A; Ohri, Sunil K

    2017-07-01

    The treatment of complex prosthetic valve endocarditis (PVE) with aortic root abscess remains a surgical challenge. Several studies support the use of biological tissues to minimize the risk of recurrent infection. We present our initial surgical experience with the use of an aortic xenograft conduit for aortic valve and root replacement. Between October 2013 and August 2015, 15 xenograft bioconduits were implanted for complex PVE with abscess (13.3% female). In 6 patients, concomitant procedures were performed: coronary bypass (n=1), mitral valve replacement (n=5) and tricuspid annuloplasty (n=1). The mean age at operation was 60.3±15.5 years. The mean Logistic European system for cardiac operating risk evaluation (EuroSCORE) was 46.6±23.6. The median follow-up time was 607±328 days (range: 172-1074 days). There were two in-hospital deaths (14.3% mortality), two strokes (14.3%) and seven patients required permanent pacemaker insertion for conduction abnormalities (46.7%). The mean length of hospital stay was 26 days. At pre-discharge echocardiography, the conduit mean gradient was 9.3±3.3mmHg and there was either none (n=6), trace (n=6) or mild aortic insufficiency (n=1). There was no incidence of mid-term death, prosthesis-related complications or recurrent endocarditis. Xenograft bioconduits may be safe and effective for aortic valve and root replacement for complex PVE with aortic root abscess. Although excess early mortality reflects the complexity of the patient population, there was good valve hemodynamics, with no incidence of recurrent endocarditis or prosthesis failure in the mid-term. Our data support the continued use and evaluation of this biological prosthesis in this high-risk patient cohort.

  12. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Severe right heart failure in a patient with Grave's disease.

    PubMed

    Xenopoulos, N P; Braden, G A; Applegate, R J

    1996-11-01

    This brief report presents a patient with isolated right heart failure and two rare underlying causes, hyperthyroidism and dysplastic tricuspid valve. Repair of the tricuspid valve and treatment of the hyperthyroidism were both essential for successful treatment of the right heart failure. Most important, recrudescence of hyperthyroidism in this patient was associated with reappearance of florid right heart failure. This report provides further information about a potential linkage of hyperthyroidism and severe right heart failure.

  14. Radiopaque markers equal gastrografin in the study of small bowel obstructions (SBO): a preliminary study.

    PubMed

    Basile, Marco; Galica, Vikiela

    2013-01-01

    To compare the diagnostic accuracy of a consolidated method (i.e.gastrografin) and a new one (i.e.radiopaque markers) in detecting complete intestinal obstruction. Twenty-one patients with suspected small bowel obstruction were enrolled and received at admission orally 100 ml of Gastrografin and 10 radiopaque markers at the same time. A series of plain abdominal radiograms was taked and evaluated to decide whether the obstruction was complete or not. The results of radiological evaluations were not disclosed to the surgeons responsible for the patient's treatment, therefore clinical decisions were assumed on clinical grounds only. In 16 out of the 21 enrolled patients both methods demonstrated only a partial obstruction; clinically none of them required surgery. Five patients showed complete bowel obstruction by the radiopaque markers method; out of those the gastrografin study showed a complete obstruction in four of them. All of them were operated on. In the fifth case it was not clear if the gastrografin had passed through the ileum-cecal valve or not. The unclear clinical picture induced to perform a TC that revealed that a small quantity of gastrografin had passed the ileo-cecal valve but there was a complete small bowel occlusion due to an internal hernia requiring a surgical treatment (thus implying a false negative picture). This preliminary study showed that both methods are effective in the early diagnosis of complete SBO. The use of radiopaque markers could avoid some false negatives of the gastrografin method and is significantly less expensive.

  15. Hypertrophic obstructive cardiomyopathy: the Mayo Clinic experience.

    PubMed

    Kotkar, Kunal D; Said, Sameh M; Dearani, Joseph A; Schaff, Hartzell V

    2017-07-01

    Hypertrophic cardiomyopathy (HCM) is a primary myocardial disease characterized by left ventricular hypertrophy in the absence of other etiologies. Clinical presentation may vary from asymptomatic to sudden cardiac death. Medical treatment is the first-line therapy for symptomatic patients. Extended left ventricular septal myectomy is the procedure of choice if medical treatment is unsuccessful or intolerable. More than 3,000 patients have had septal myectomy for HCM at the Mayo Clinic (MN, USA) from 1993 to 2016. Risk of hospital death after isolated septal myectomy for obstructive HCM is <1% and is similar to the risk of operation for elective mitral valve repair. Complications, such as complete heart block requiring permanent pacemaker, are uncommon (2%), although partial or complete left bundle branch block is a frequent finding on the postoperative ECG. Relief of left ventricular outflow tract (LVOT) obstruction with septal myectomy dramatically improves symptoms and exercise capacity in symptomatic patients with obstructive HCM. More than 90% of severely symptomatic patients have improvement by at least two functional classes, and reduction of outflow gradients by myectomy decreases or eliminates symptoms of dyspnea, angina and/or syncope. Basal obstruction with systolic anterior motion (SAM) is treated by transaortic myectomy. The transapical approach was applied in 115 patients with obstructive midventricular and apical variants of HCM between 1993 and 2012. All patients with midventricular obstruction had gradient relief and none developed an apical aneurysm or ventricular septal defect. Recurrent obstruction after satisfactory myectomy was rare. Septal myectomy effectively and definitively relieves LVOT obstruction and cardiac symptoms in patients with obstructive HCM. In experienced centers, early mortality for isolated septal myectomy is less than 1%, and overall results are excellent and continue to improve in the current era.

  16. Posterior urethral valves: 10 years audit of epidemiologic, diagnostic and therapeutic aspects in Yaoundé gynaeco-obstetric and paediatric hospital.

    PubMed

    Tambo, Faustin Felicien Mouafo; Tolefac, Paul Nkemtendong; Ngowe, Marcelin Ngowe; Minkande, Jacqueline Ze; Mbouche, Landry; Guemkam, Georgette; Telelen, Neville Alemnju; Angwafo, Fru Fobuzshi; Sosso, Aurelien Maurice

    2018-05-21

    The incidence of posterior urethral valve (PUV) is estimated at 1:5000-1:8000 males. It is the most common paediatric urologic urgency and the most common cause of male obstructive uropathy and chronic renal failure in children. The study aimed to describe the experience of Yaoundé gynaeco-obstetrics and paediatric hospital in the management of PUV. Retrospectively, medical records were retrieved over a ten year period and all data recorded and analyzed for study objectives. Patients were called and evaluated for outcomes regarding morbidity and mortality. A total of 18 patients all males were managed over the ten year period, given prevalence of 13 cases/100,000 admissions and an admission rate of 2 per annum. The median age at presentation was 22 months and 13 (72.2%) participants presented late. Voiding urethrocystogram was done in all the participants where it showed dilated and elongated posterior urethral valves in 16 (88.9%) of the cases. Endoscopic valve ablation resulted in the relief of obstruction in all but 3 (16.7%) participants that had residual valves and 2 (11.2%) participants that had urethral stenosis. Type I valves were most common in 14 (78.0%) participants. The mean duration of follow up was 34.56 ± 21.47 months. Complications at final follow up were: 10 (55.6%) chronic renal failure, 2 (11.2%) end-stage renal failure. The case fatality rate was 5.6%. Many patients present late in our setting with already established complications. There is the need to counsel parents/guardians on the importance of long-term follow up after relief of obstruction.

  17. Safety of minimally invasive mitral valve surgery without aortic cross-clamp.

    PubMed

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Kumar, Sathappan; Solenkova, Nataliya V; Kaiser, Clayton A; Greelish, James P; Balaguer, Jorge M; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Kim, Betty S; Byrne, John G

    2008-05-01

    We developed a technique for open heart surgery through a small (5 cm) right-anterolateral thoracotomy without aortic cross-clamp. One hundred and ninety-five consecutive patients (103 male and 92 female), age 69 +/- 8 years, underwent surgery between January 2006 and July 2007. Mean preoperative New York Heart Association function class was 2.2 +/- 0.7. Thirty-five patients (18%) had an ejection fraction 0.35 or less. Cardiopulmonary bypass was instituted through femoral (176 of 195, 90%), axillary (18 of 195, 9%), or direct aortic (1 of 195, 0.5%) cannulation. Under cold fibrillatory arrest (mean temperature 28.2 degrees C) without aortic cross-clamp, mitral valve repair (72 of 195, 37%), mitral valve replacement (117 of 195, 60%), or other (6 of 195, 3%) procedures were performed. Concomitant procedures included maze (45 of 195, 23%), patent foramen ovale closure (42 of 195, 22%) and tricuspid valve repair (16 of 195, 8%), or replacement (4 of 195, 2%). Thirty-day mortality was 3% (6 of 195). Duration of fibrillatory arrest, cardiopulmonary bypass, and "skin to skin" surgery were 88 +/- 32, 118 +/- 52, and 280 +/- 78 minutes, respectively. Ten patients (5%) underwent reexploration for bleeding and 44% did not receive any blood transfusions. Six patients (3%) sustained a postoperative stroke, eight (4%) developed low cardiac output syndrome, and two (1%) developed renal failure requiring hemodialysis. Mean length of hospital stay was 7 +/- 4.8 days. This simplified technique of minimally invasive open heart surgery is safe and easily reproducible. Fibrillatory arrest without aortic cross-clamping, with coronary perfusion against an intact aortic valve, does not increase the risk of stroke or low cardiac output. It may be particularly useful in higher risk patients in whom sternotomy with aortic clamping is less desirable.

  18. Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial.

    PubMed

    McElhinney, Doff B; Cheatham, John P; Jones, Thomas K; Lock, James E; Vincent, Julie A; Zahn, Evan M; Hellenbrand, William E

    2011-12-01

    Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational Device Exemption trial. Existing conduit stents from a prior catheterization were present in 37 patients (25%, fractured in 12); 1 or more new prestents were placed at the TPV implant catheterization in 51 patients. During follow-up (median, 30 months), MSF was diagnosed in 39 patients. Freedom from a diagnosis of MSF was 77±4% at 14 months (after the 1-year evaluation window) and 60±9% at 39 months (3-year window). On multivariable analysis, implant within an existing stent, new prestent, or bioprosthetic valve (combined variable) was associated with longer freedom from MSF (P<0.001), whereas TPV compression (P=0.01) and apposition to the anterior chest wall (P=0.02) were associated with shorter freedom from MSF. Freedom from RVOT reintervention was 86±4% at 27 months. Among patients with a MSF, freedom from RVOT reintervention after MSF diagnosis was 49±10% at 2 years. Factors associated with reintervention were similar to those for MSF. MSF was common after TPV implant in this multicenter experience and was more likely in patients with severely obstructed RVOT conduits and when the TPV was directly behind the anterior chest wall and/or clearly compressed. A TPV implant site protected by a prestent or bioprosthetic valve was associated with lower risk of MSF and reintervention.

  19. The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation.

    PubMed

    Silaschi, Miriam; Conradi, Lenard; Wendler, Olaf; Schlingloff, Friederike; Kappert, Utz; Rastan, Ardawan J; Baumbach, Hardy; Holzhey, David; Eichinger, Walter; Bader, Ralf; Treede, Hendrik

    2018-06-01

    We present 1-year outcomes of the post-market registry of a next-generation transcatheter heart valve used for aortic regurgitation (AR). Transcatheter aortic valve replacement (TAVR) is routine in high-risk patients with aortic stenosis but is not recommended for AR. The JenaValve™ (JenaValve Technology GmbH, Munich, Germany) overcomes technical challenges in AR patients through a leaflet clipping mechanism. The JenaValve EvalUation of Long Term Performance and Safety In PaTients with SEvere Aortic Stenosis oR Aortic Insufficiency (JUPITER) Registry is a European study to evaluate safety and effectiveness of this THV. From 2012-2015, 30 patients with AR were enrolled. Mean age was 74.4 ± 9.3 years. Procedural success was 96.7% (29/30). One patient was converted to open surgery. No annular rupture or coronary ostia obstruction occurred. Mortality at 30 days was 10.0% (3/30). Combined safety endpoint was met in 13.3% (4/30). Paravalvular regurgitation was not present/trivial in 84.6% (22/26) and mild in 15.4% (4/26). Rate of permanent pacemaker implantation was 3.8% (1/26). One-year Kaplan-Meier survival was 79.9%, one-year combined efficacy was 73.1% (19/30). No further strokes were observed during 1 year of follow-up. The JenaValve overcomes technical challenges of TAVR in AR through a clipping mechanism. We report satisfactory outcomes of a multicenter registry using the JenaValve for predominant AR, as rate of THV embolization, residual AR and permanent pacemaker implantation was low. One-year results using the JenaValve for AR encourage its use for this indication. © 2017 Wiley Periodicals, Inc.

  20. Long-term evaluation of a new ventriculoperitoneal shunt valve system in a dog.

    PubMed

    Filgueiras, Richard da Rocha; Martins, Christine de Souza; de Almeida, Ricardo Miyasaka; Silva, Rosana Marques; da Rocha, Martha de Souza Teixeira; Firmino, Fernanda de Paula; Maguilnik, Samara; Medeiros, Luíza Quintão

    2009-12-01

    To report on the use of a new ventriculoperitoneal shunt (VPS) valve system utilized in a dog with hydrocephalus and to describe the clinical course over 20 months after implantation. A 3-month-old female Lhasa Apso dog was presented with lateral strabismus, domed calvarium, and visual deficits. A lateral skull radiograph revealed a persistent fontanelle. Transfontanellar ultrasonographic examination and computed tomographic examination showed excessive accumulation of fluid within the ventricles. The owner had observed symptoms as early as 1 month after birth, suggesting congenital hydrocephalus. A VPS with a new valve system that inhibits cerebrospinal fluid overdrainage and obstruction of the catheter was implanted. The dog showed clinical improvement 48 hours after the procedure. Twenty days after shunt implantation, another computed tomography scan was performed that showed reduction in ventricle size. The evaluation of VPS patency was carried out 20 months after surgery and demonstrated that the system was working properly without obstruction. There are reports in the literature describing the use of several devices to perform VPS in dogs. A new device not previously described in the veterinary literature was used in this case report, and according to the manufacturer's description, this device inhibits proteinaceous build-up, which is usually responsible for subsequent catheter obstructions.