Sample records for obtain greater accuracy

  1. Multisensor Arrays for Greater Reliability and Accuracy

    NASA Technical Reports Server (NTRS)

    Immer, Christopher; Eckhoff, Anthony; Lane, John; Perotti, Jose; Randazzo, John; Blalock, Norman; Ree, Jeff

    2004-01-01

    Arrays of multiple, nominally identical sensors with sensor-output-processing electronic hardware and software are being developed in order to obtain accuracy, reliability, and lifetime greater than those of single sensors. The conceptual basis of this development lies in the statistical behavior of multiple sensors and a multisensor-array (MSA) algorithm that exploits that behavior. In addition, advances in microelectromechanical systems (MEMS) and integrated circuits are exploited. A typical sensor unit according to this concept includes multiple MEMS sensors and sensor-readout circuitry fabricated together on a single chip and packaged compactly with a microprocessor that performs several functions, including execution of the MSA algorithm. In the MSA algorithm, the readings from all the sensors in an array at a given instant of time are compared and the reliability of each sensor is quantified. This comparison of readings and quantification of reliabilities involves the calculation of the ratio between every sensor reading and every other sensor reading, plus calculation of the sum of all such ratios. Then one output reading for the given instant of time is computed as a weighted average of the readings of all the sensors. In this computation, the weight for each sensor is the aforementioned value used to quantify its reliability. In an optional variant of the MSA algorithm that can be implemented easily, a running sum of the reliability value for each sensor at previous time steps as well as at the present time step is used as the weight of the sensor in calculating the weighted average at the present time step. In this variant, the weight of a sensor that continually fails gradually decreases, so that eventually, its influence over the output reading becomes minimal: In effect, the sensor system "learns" which sensors to trust and which not to trust. The MSA algorithm incorporates a criterion for deciding whether there remain enough sensor readings that

  2. Estimating Software-Development Costs With Greater Accuracy

    NASA Technical Reports Server (NTRS)

    Baker, Dan; Hihn, Jairus; Lum, Karen

    2008-01-01

    COCOMOST is a computer program for use in estimating software development costs. The goal in the development of COCOMOST was to increase estimation accuracy in three ways: (1) develop a set of sensitivity software tools that return not only estimates of costs but also the estimation error; (2) using the sensitivity software tools, precisely define the quantities of data needed to adequately tune cost estimation models; and (3) build a repository of software-cost-estimation information that NASA managers can retrieve to improve the estimates of costs of developing software for their project. COCOMOST implements a methodology, called '2cee', in which a unique combination of well-known pre-existing data-mining and software-development- effort-estimation techniques are used to increase the accuracy of estimates. COCOMOST utilizes multiple models to analyze historical data pertaining to software-development projects and performs an exhaustive data-mining search over the space of model parameters to improve the performances of effort-estimation models. Thus, it is possible to both calibrate and generate estimates at the same time. COCOMOST is written in the C language for execution in the UNIX operating system.

  3. Accuracy of electron densities obtained via Koopmans-compliant hybrid functionals

    NASA Astrophysics Data System (ADS)

    Elmaslmane, A. R.; Wetherell, J.; Hodgson, M. J. P.; McKenna, K. P.; Godby, R. W.

    2018-04-01

    We evaluate the accuracy of electron densities and quasiparticle energy gaps given by hybrid functionals by directly comparing these to the exact quantities obtained from solving the many-electron Schrödinger equation. We determine the admixture of Hartree-Fock exchange to approximate exchange-correlation in our hybrid functional via one of several physically justified constraints, including the generalized Koopmans' theorem. We find that hybrid functionals yield strikingly accurate electron densities and gaps in both exchange-dominated and correlated systems. We also discuss the role of the screened Fock operator in the success of hybrid functionals.

  4. The Data Evaluation for Obtaining Accuracy and Reliability

    NASA Astrophysics Data System (ADS)

    Kim, Chang Geun; Chae, Kyun Shik; Lee, Sang Tae; Bhang, Gun Woong

    2012-11-01

    Nemours scientific measurement results are flooded from the paper, data book, etc. as fast growing of internet. We meet many different measurement results on the same measurand. In this moment, we are face to choose most reliable one out of them. But it is not easy to choose and use the accurate and reliable data as we do at an ice cream parlor. Even expert users feel difficult to distinguish the accurate and reliable scientific data from huge amount of measurement results. For this reason, the data evaluation is getting more important as the fast growing of internet and globalization. Furthermore the expressions of measurement results are not in standardi-zation. As these need, the international movement has been enhanced. At the first step, the global harmonization of terminology used in metrology and the expression of uncertainty in measurement were published in ISO. These methods are wide spread to many area of science on their measurement to obtain the accuracy and reliability. In this paper, it is introduced that the GUM, SRD and data evaluation on atomic collisions.

  5. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions.

    PubMed

    Ender, Andreas; Mehl, Albert

    2015-01-01

    To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 μm (VSE) to 60.2 μm (POE), and precision ranged from 12.3 μm (VSE) to 66.7 μm (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.

  6. Assessing the accuracy of weather radar to track intense rain cells in the Greater Lyon area, France

    NASA Astrophysics Data System (ADS)

    Renard, Florent; Chapon, Pierre-Marie; Comby, Jacques

    2012-01-01

    The Greater Lyon is a dense area located in the Rhône Valley in the south east of France. The conurbation counts 1.3 million inhabitants and the rainfall hazard is a great concern. However, until now, studies on rainfall over the Greater Lyon have only been based on the network of rain gauges, despite the presence of a C-band radar located in the close vicinity. Consequently, the first aim of this study was to investigate the hydrological quality of this radar. This assessment, based on comparison of radar estimations and rain-gauges values concludes that the radar data has overall a good quality since 2006. Given this good accuracy, this study made a next step and investigated the characteristics of intense rain cells that are responsible of the majority of floods in the Greater Lyon area. Improved knowledge on these rainfall cells is important to anticipate dangerous events and to improve the monitoring of the sewage system. This paper discusses the analysis of the ten most intense rainfall events in the 2001-2010 period. Spatial statistics pointed towards straight and linear movements of intense rainfall cells, independently on the ground surface conditions and the topography underneath. The speed of these cells was found nearly constant during a rainfall event, but depend from event to ranges on average from 25 to 66 km/h.

  7. Reliability and Accuracy of Static Parameters Obtained From Ink and Pressure Platform Footprints.

    PubMed

    Zuil-Escobar, Juan Carlos; Martínez-Cepa, Carmen Belén; Martín-Urrialde, Jose Antonio; Gómez-Conesa, Antonia

    2016-09-01

    The purpose of this study was to evaluate the accuracy and the intrarater reliability of arch angle (AA), Staheli Index (SI), and Chippaux-Smirak Index (CSI) obtained from ink and pressure platform footprints. We obtained AA, SI, and CSI measurements from ink pedigraph footprints and pressure platform footprints in 40 healthy participants (aged 25.65 ± 5.187 years). Intrarater reliability was calculated for all parameters obtained using the 2 methods. Standard error of measurement and minimal detectable change were also calculated. A repeated-measure analysis of variance was used to identify differences between ink and pressure platform footprints. Intraclass correlation coefficient and Bland and Altman plots were used to assess similar parameters obtained using different methods. Intrarater reliability was >0.9 for all parameters and was slightly higher for the ink footprints. No statistical difference was reported in repeated-measure analysis of variance for any of the parameters. Intraclass correlation coefficient values from AA, SI, and CSI that were obtained using ink footprints and pressure platform footprints were excellent, ranging from 0.797 to 0.829. However, pressure platform overestimated AA and underestimated SI and CSI. Our study revealed that AA, SI, and CSI were similar regardless of whether the ink or pressure platform method was used. In addition, the parameters indicated high intrarater reliability and were reproducible. Copyright © 2016. Published by Elsevier Inc.

  8. Accuracy Investigation of Creating Orthophotomaps Based on Images Obtained by Applying Trimble-UX5 UAV

    NASA Astrophysics Data System (ADS)

    Hlotov, Volodymyr; Hunina, Alla; Siejka, Zbigniew

    2017-06-01

    The main purpose of this work is to confirm the possibility of making largescale orthophotomaps applying unmanned aerial vehicle (UAV) Trimble- UX5. A planned altitude reference of the studying territory was carried out before to the aerial surveying. The studying territory has been marked with distinctive checkpoints in the form of triangles (0.5 × 0.5 × 0.2 m). The checkpoints used to precise the accuracy of orthophotomap have been marked with similar triangles. To determine marked reference point coordinates and check-points method of GNSS in real-time kinematics (RTK) measuring has been applied. Projecting of aerial surveying has been done with the help of installed Trimble Access Aerial Imaging, having been used to run out the UX5. Aerial survey out of the Trimble UX5 UAV has been done with the help of the digital camera SONY NEX-5R from 200m and 300 m altitude. These aerial surveying data have been calculated applying special photogrammetric software Pix 4D. The orthophotomap of the surveying objects has been made with its help. To determine the precise accuracy of the got results of aerial surveying the checkpoint coordinates according to the orthophotomap have been set. The average square error has been calculated according to the set coordinates applying GNSS measurements. A-priori accuracy estimation of spatial coordinates of the studying territory using the aerial surveying data have been calculated: mx=0.11 m, my=0.15 m, mz=0.23 m in the village of Remeniv and mx=0.26 m, my=0.38 m, mz=0.43 m in the town of Vynnyky. The accuracy of determining checkpoint coordinates has been investigated using images obtained out of UAV and the average square error of the reference points. Based on comparative analysis of the got results of the accuracy estimation of the made orthophotomap it can be concluded that the value the average square error does not exceed a-priori accuracy estimation. The possibility of applying Trimble UX5 UAV for making large

  9. Estimation of accuracy of time synchronization obtained by means of clock transportation

    NASA Astrophysics Data System (ADS)

    Zhang, Yuzhen; Ma, Dekang; Jin, Wenjing; Zhao, Gang; Huang, Peicheng

    A portable clock experiment was carried out in October 1985 between Shanghai Observatory and Beijing Observatory using a small quartz clock made in Switzerland. The accuracy of time synchronization in 5 days is 70.18 microsec and the accuracy of determining the transmission time of short wave is satisfactory for reduction of the astronomical observations to the same master clock.

  10. 7 CFR 356.3 - Property valued at greater than $10,000; notice of seizure and civil action to obtain forfeiture.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 5 2012-01-01 2012-01-01 false Property valued at greater than $10,000; notice of seizure and civil action to obtain forfeiture. 356.3 Section 356.3 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE...

  11. 14 CFR 61.327 - How do I obtain privileges to operate a light-sport aircraft that has a VH greater than 87 knots...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... light-sport aircraft that has a VH greater than 87 knots CAS? 61.327 Section 61.327 Aeronautics and...: PILOTS, FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS Sport Pilots § 61.327 How do I obtain privileges to operate a light-sport aircraft that has a VH greater than 87 knots CAS? If you hold a sport pilot...

  12. Planialtimetric Accuracy Evaluation of Digital Surface Model (dsm) and Digital Terrain Model (dtm) Obtained from Aerial Survey with LIDAR

    NASA Astrophysics Data System (ADS)

    Cruz, C. B. M.; Barros, R. S.; Rabaco, L. M. L.

    2012-07-01

    It's noticed a significant increase in the development of orbital and airborne sensors that enable the extraction of three-dimensional data. Consequently, it's important the increment of studies about the quality of altimetric values derived from these sensors to verify if the improvements implemented in the acquisition of data may influence the results. In this context, as part of a larger project that aims to evaluate the accuracy of various sensors, this work aims to analysis the planialtimetric accuracy of DSM and DTM generated from an aerial survey with LIDAR, using as reference for the planimetric analysis of the orthophotos obtained. The project was developed for an area of São Sebastião city, located in the basin of the North Coast of São Paulo state. The area's relief is very steep, with a predominance of dense forest vegetation, typical of the Atlantic Forest. All points have been established in the field, with the use of GNSS of one frequency (L1) through static relative positioning, acquiring a minimum of 1,500 epochs, for a distance less than 20 km to the base. In this work it's considered the Brazilian standard specifications for classification of cartographic bases (PEC). The Brazilian company responsible for the aerial survey (LACTEC) gave the following products for analysis: point clouds in raw format (x, y, z) using orthometric heights; point clouds (first and last pulse) for each range of flight to verify systematic errors; DTM uniformly spaced, filtering small natural obstacles, buildings and vegetation, in Geotiff format; DSM also uniformly spaced, in Geotiff format; and the mosaic of georeferenced digital images. The analysis realized on products from the LIDAR indicated their adoption to the scales 1:2,000 (Class A for the orthophotos and Class B for the DTM) and 1:5,000 (class C for the DSM). There were no indications of trends in the results. The average error was 0.01 m. It's important that new areas with different topographic

  13. High Accuracy Temperature Measurements Using RTDs with Current Loop Conditioning

    NASA Technical Reports Server (NTRS)

    Hill, Gerald M.

    1997-01-01

    To measure temperatures with a greater degree of accuracy than is possible with thermocouples, RTDs (Resistive Temperature Detectors) are typically used. Calibration standards use specialized high precision RTD probes with accuracies approaching 0.001 F. These are extremely delicate devices, and far too costly to be used in test facility instrumentation. Less costly sensors which are designed for aeronautical wind tunnel testing are available and can be readily adapted to probes, rakes, and test rigs. With proper signal conditioning of the sensor, temperature accuracies of 0.1 F is obtainable. For reasons that will be explored in this paper, the Anderson current loop is the preferred method used for signal conditioning. This scheme has been used in NASA Lewis Research Center's 9 x 15 Low Speed Wind Tunnel, and is detailed.

  14. Theoferometer for High Accuracy Optical Alignment and Metrology

    NASA Technical Reports Server (NTRS)

    Toland, Ronald; Leviton, Doug; Koterba, Seth

    2004-01-01

    The accurate measurement of the orientation of optical parts and systems is a pressing problem for upcoming space missions, such as stellar interferometers, requiring the knowledge and maintenance of positions to the sub-arcsecond level. Theodolites, the devices commonly used to make these measurements, cannot provide the needed level of accuracy. This paper describes the design, construction, and testing of an interferometer system to fill the widening gap between future requirements and current capabilities. A Twyman-Green interferometer mounted on a 2 degree of freedom rotation stage is able to obtain sub-arcsecond, gravity-referenced tilt measurements of a sample alignment cube. Dubbed a 'theoferometer,' this device offers greater ease-of-use, accuracy, and repeatability than conventional methods, making it a suitable 21st-century replacement for the theodolite.

  15. Impacts of land use/cover classification accuracy on regional climate simulations

    NASA Astrophysics Data System (ADS)

    Ge, Jianjun; Qi, Jiaguo; Lofgren, Brent M.; Moore, Nathan; Torbick, Nathan; Olson, Jennifer M.

    2007-03-01

    Land use/cover change has been recognized as a key component in global change. Various land cover data sets, including historically reconstructed, recently observed, and future projected, have been used in numerous climate modeling studies at regional to global scales. However, little attention has been paid to the effect of land cover classification accuracy on climate simulations, though accuracy assessment has become a routine procedure in land cover production community. In this study, we analyzed the behavior of simulated precipitation in the Regional Atmospheric Modeling System (RAMS) over a range of simulated classification accuracies over a 3 month period. This study found that land cover accuracy under 80% had a strong effect on precipitation especially when the land surface had a greater control of the atmosphere. This effect became stronger as the accuracy decreased. As shown in three follow-on experiments, the effect was further influenced by model parameterizations such as convection schemes and interior nudging, which can mitigate the strength of surface boundary forcings. In reality, land cover accuracy rarely obtains the commonly recommended 85% target. Its effect on climate simulations should therefore be considered, especially when historically reconstructed and future projected land covers are employed.

  16. Accuracy of single-abutment digital cast obtained using intraoral and cast scanners.

    PubMed

    Lee, Jae-Jun; Jeong, Ii-Do; Park, Jin-Young; Jeon, Jin-Hun; Kim, Ji-Hwan; Kim, Woong-Chul

    2017-02-01

    Scanners are frequently used in the fabrication of dental prostheses. However, the accuracy of these scanners is variable, and little information is available. The purpose of this in vitro study was to compare the accuracy of cast scanners with that of intraoral scanners by using different image impression techniques. A poly(methyl methacrylate) master model was fabricated to replicate a maxillary first molar single-abutment tooth model. The master model was scanned with an accurate engineering scanner to obtain a true value (n=1) and with 2 intraoral scanners (CEREC Bluecam and CEREC Omnicam; n=6 each). The cast scanner scanned the master model and duplicated the dental stone cast from the master model (n=6). The trueness and precision of the data were measured using a 3-dimensional analysis program. The Kruskal-Wallis test was used to compare the different sets of scanning data, followed by a post hoc Mann-Whitney U test with a significance level modified by Bonferroni correction (α/6=.0083). The type 1 error level (α) was set at .05. The trueness value (root mean square: mean ±standard deviation) was 17.5 ±1.8 μm for the Bluecam, 13.8 ±1.4 μm for the Omnicam, 17.4 ±1.7 μm for cast scanner 1, and 12.3 ±0.1 μm for cast scanner 2. The differences between the Bluecam and the cast scanner 1 and between the Omnicam and the cast scanner 2 were not statistically significant (P>.0083), but a statistically significant difference was found between all the other pairs (P<.0083). The precision of the scanners was 12.7 ±2.6 μm for the Bluecam, 12.5 ±3.7 μm for the Omnicam, 9.2 ±1.2 μm for cast scanner 1, and 6.9 ±2.6 μm for cast scanner 2. The differences between Bluecam and Omnicam and between Omnicam and cast scanner 1 were not statistically significant (P>.0083), but there was a statistically significant difference between all the other pairs (P<.0083). An Omnicam in video image impression had better trueness than a cast scanner but with a similar

  17. Disfluency prompts analytic thinking--but not always greater accuracy: response to Thompson et al. (2013).

    PubMed

    Alter, Adam L; Oppenheimer, Daniel M; Epley, Nicholas

    2013-08-01

    In this issue of Cognition, Thompson and her colleagues challenge the results from a paper we published several years ago (Alter, Oppenheimer, Epley, & Eyre, 2007). That paper demonstrated that metacognitive difficulty or disfluency can trigger more analytical thinking as measured by accuracy on several reasoning tasks. In their experiments, Thompson et al. find evidence that people process information more deeply-but not necessarily more accurately-when they experience disfluency. These results are consistent with our original theorizing, but the authors misinterpret it as counter-evidence because they suggest that accuracy (and even confidence) is a measure of deeper processing rather than a contingent outcome of such processing. We further suggest that Thompson et al. err when they discriminate between "perceptual fluency" and "answer fluency," the former of which is an element of the latter. Thompson et al. advance research by adding reaction time as a measure of deeper cognitive processing, but we caution against misinterpreting the meaning of accuracy. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Age-related differences in strategy knowledge updating: blocked testing produces greater improvements in metacognitive accuracy for younger than older adults.

    PubMed

    Price, Jodi; Hertzog, Christopher; Dunlosky, John

    2008-09-01

    Age-related differences in updating knowledge about strategy effectiveness after task experience have not been consistently found, perhaps because the magnitude of observed knowledge updating has been rather meager for both age groups. We examined whether creating homogeneous blocks of recall tests based on two strategies used at encoding (imagery and repetition) would enhance people's learning about strategy effects on recall. Younger and older adults demonstrated greater knowledge updating (as measured by questionnaire ratings of strategy effectiveness and by global judgments of performance) with blocked (versus random) testing. The benefit of blocked testing for absolute accuracy of global predictions was smaller for older than younger adults. However, individual differences in correlations of strategy effectiveness ratings and postdictions showed similar upgrades for both age groups. Older adults learn about imagery's superior effectiveness but do not accurately estimate the magnitude of its benefit, even after blocked testing.

  19. Feasibility and accuracy of molecular testing in specimens obtained with small biopsy forceps: comparison with the results of surgical specimens.

    PubMed

    Oki, Masahide; Yatabe, Yasushi; Saka, Hideo; Kitagawa, Chiyoe; Kogure, Yoshihito; Ichihara, Shu; Moritani, Suzuko

    2015-01-01

    During bronchoscopy, small biopsy forceps are increasingly used for the diagnosis of peripheral pulmonary lesions. However, it is unclear whether the formalin-fixed paraffin-embedded specimens sampled with the small biopsy forceps are suitable for the determination of genotypes which become indispensable for the management decision regarding patients with non-small cell lung cancer. The aim of this study was to evaluate the feasibility and accuracy of molecular testing in the specimens obtained with 1.5-mm small biopsy forceps. We examined specimens in 91 patients, who were enrolled in our previous 3 studies on the usefulness of thin bronchoscopes and given a diagnosis of non-small cell lung cancer by bronchoscopy with the 1.5-mm biopsy forceps, and then underwent surgical resection. An experienced pathologist examined paraffin-embedded specimens obtained by bronchoscopic biopsy or surgical resection in a blind fashion on epidermal growth factor receptor (EGFR) mutations, anaplastic lymphoma kinase (ALK) rearrangements and KRAS mutations. Twenty-five (27%), 2 (2%) and 5 (5%) patients had an EGFR mutation, ALK rearrangement and KRAS mutation, respectively, based on the results in surgical specimens. EGFR, ALK and KRAS testing with bronchoscopic specimens was feasible in 82 (90%), 86 (95%) and 83 (91%) patients, respectively. If molecular testing was feasible, the accuracy of EGFR, ALK and KRAS testing with bronchoscopic specimens for the results with surgical specimens was 98, 100 and 98%, respectively. The results of molecular testing in the formalin-fixed paraffin-embedded specimens obtained with the small forceps, in which the genotype could be evaluated, correlated well with those in surgically resected specimens.

  20. Determination of the Ephemeris Accuracy for AJISAI, LAGEOS and ETALON Satellites, Obtained with A Simplified Numerical Motion Model Using the ILRS Coordinates

    NASA Astrophysics Data System (ADS)

    Kara, I. V.

    This paper describes a simplified numerical model of passive artificial Earth satellite (AES) motion. The model accuracy is determined using the International Laser Ranging Service (ILRS) highprecision coordinates. Those data are freely available on http://ilrs.gsfc.nasa.gov. The differential equations of the AES motion are solved by the Everhart numerical method of 17th and 19th orders with the integration step automatic correction. The comparison between the AES coordinates computed with the motion model and the ILRS coordinates enabled to determine the accuracy of the ephemerides obtained. As a result, the discrepancy of the computed Etalon-1 ephemerides from the ILRS data is about 10'' for a one-year ephemeris.

  1. Older and Younger Adults’ Accuracy in Discerning Health and Competence in Older and Younger Faces

    PubMed Central

    Zebrowitz, Leslie A.; Franklin, Robert G.; Boshyan, Jasmine; Luevano, Victor; Agrigoroaei, Stefan; Milosavljevic, Bosiljka; Lachman, Margie E.

    2015-01-01

    We examined older and younger adults’ accuracy judging the health and competence of faces. Accuracy differed significantly from chance and varied with face age but not rater age. Health ratings were more accurate for older than younger faces, with the reverse for competence ratings. Accuracy was greater for low attractive younger faces, but not for low attractive older faces. Greater accuracy judging older faces’ health was paralleled by greater validity of attractiveness and looking older as predictors of their health. Greater accuracy judging younger faces’ competence was paralleled by greater validity of attractiveness and a positive expression as predictors of their competence. Although the ability to recognize variations in health and cognitive ability is preserved in older adulthood, the effects of face age on accuracy and the different effects of attractiveness across face age may alter social interactions across the life span. PMID:25244467

  2. EFFECT OF CERVICAL RELINING OF ACRYLIC RESIN COPINGS ON THE ACCURACY OF STONE DIES OBTAINED USING A POLYETHER IMPRESSION MATERIAL

    PubMed Central

    de Sá, André Tomazini Gomes; de Freitas, César Antunes; de Sá, Fátima Cristina; Ursi, Wagner José Silva; Simões, Tânia Christina; de Freitas, Márcia Furtado Antunes

    2008-01-01

    The purpose of this study was to evaluate the accuracy of the respective dies after polyether elastomeric procedure in the presence or absence of cervical contact of the acrylic resin shell with the cervical region, establishing a comparison to dies obtained with stock trays. This study consisted of three groups with 10 specimens each: 1) acrylic copings without cervical contact, (cn); 2) acrylic copings with cervical contact (cc); 3) perforated stock tray, (st). The accuracy of the resulting dies was verified with the aid of a master crown, precisely fit to the master steel die. ANOVA test found statistically significant differences among groups (p<0.001). Tukey's test found that the smallest discrepancy occurred in group cn, followed by cc, while the st group presented the highest difference (cc x cn: p=0.007; st x cn: p<0.001; st x cc: p<0.001). PMID:19089282

  3. Theoretical evaluation of accuracy in position and size of brain activity obtained by near-infrared topography

    NASA Astrophysics Data System (ADS)

    Kawaguchi, Hiroshi; Hayashi, Toshiyuki; Kato, Toshinori; Okada, Eiji

    2004-06-01

    Near-infrared (NIR) topography can obtain a topographical distribution of the activated region in the brain cortex. Near-infrared light is strongly scattered in the head, and the volume of tissue sampled by a source-detector pair on the head surface is broadly distributed in the brain. This scattering effect results in poor resolution and contrast in the topographic image of the brain activity. In this study, a one-dimensional distribution of absorption change in a head model is calculated by mapping and reconstruction methods to evaluate the effect of the image reconstruction algorithm and the interval of measurement points for topographic imaging on the accuracy of the topographic image. The light propagation in the head model is predicted by Monte Carlo simulation to obtain the spatial sensitivity profile for a source-detector pair. The measurement points are one-dimensionally arranged on the surface of the model, and the distance between adjacent measurement points is varied from 4 mm to 28 mm. Small intervals of the measurement points improve the topographic image calculated by both the mapping and reconstruction methods. In the conventional mapping method, the limit of the spatial resolution depends upon the interval of the measurement points and spatial sensitivity profile for source-detector pairs. The reconstruction method has advantages over the mapping method which improve the results of one-dimensional analysis when the interval of measurement points is less than 12 mm. The effect of overlapping of spatial sensitivity profiles indicates that the reconstruction method may be effective to improve the spatial resolution of a two-dimensional reconstruction of topographic image obtained with larger interval of measurement points. Near-infrared topography with the reconstruction method potentially obtains an accurate distribution of absorption change in the brain even if the size of absorption change is less than 10 mm.

  4. Obtaining identical results with double precision global accuracy on different numbers of processors in parallel particle Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cleveland, Mathew A., E-mail: cleveland7@llnl.gov; Brunner, Thomas A.; Gentile, Nicholas A.

    2013-10-15

    We describe and compare different approaches for achieving numerical reproducibility in photon Monte Carlo simulations. Reproducibility is desirable for code verification, testing, and debugging. Parallelism creates a unique problem for achieving reproducibility in Monte Carlo simulations because it changes the order in which values are summed. This is a numerical problem because double precision arithmetic is not associative. Parallel Monte Carlo, both domain replicated and decomposed simulations, will run their particles in a different order during different runs of the same simulation because the non-reproducibility of communication between processors. In addition, runs of the same simulation using different domain decompositionsmore » will also result in particles being simulated in a different order. In [1], a way of eliminating non-associative accumulations using integer tallies was described. This approach successfully achieves reproducibility at the cost of lost accuracy by rounding double precision numbers to fewer significant digits. This integer approach, and other extended and reduced precision reproducibility techniques, are described and compared in this work. Increased precision alone is not enough to ensure reproducibility of photon Monte Carlo simulations. Non-arbitrary precision approaches require a varying degree of rounding to achieve reproducibility. For the problems investigated in this work double precision global accuracy was achievable by using 100 bits of precision or greater on all unordered sums which where subsequently rounded to double precision at the end of every time-step.« less

  5. Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter.

    PubMed

    Chung, Phil Hyun; Kang, Suk; Kim, Jong Pil; Kim, Young Sung; Lee, Ho Min; Back, In Hwa; Eom, Kyeong Soo

    2016-06-01

    Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. This study involved 23 cases of greater trochanteric fractures as diagnosed using plain radiographs from January 2004 to July 2013. Until January 2008, 9 cases were examined with 3D-CT only, while 14 cases were screened with both 3D-CT and MRI scans. We analyzed diagnostic accuracy and treatment results following 3D-CT and MRI scanning. Nine cases that underwent 3D-CT only were diagnosed with isolated greater trochanteric fractures without occult intertrochanteric fractures. Of these, a patient with displacement received surgical treatment. Of the 14 patients screened using both CT and MRI, 13 were diagnosed with occult intertrochanteric fractures. Of these, 11 were treated with surgical intervention and 2 with conservative management. Three-dimensional CT has very low diagnostic accuracy in diagnosing occult intertrochanteric fractures. For this reason, MRI is recommended to confirm a suspected occult intertrochanteric fracture and to determine the most appropriate mode of treatment.

  6. Accuracy of patient-specific organ dose estimates obtained using an automated image segmentation algorithm.

    PubMed

    Schmidt, Taly Gilat; Wang, Adam S; Coradi, Thomas; Haas, Benjamin; Star-Lack, Josh

    2016-10-01

    The overall goal of this work is to develop a rapid, accurate, and automated software tool to estimate patient-specific organ doses from computed tomography (CT) scans using simulations to generate dose maps combined with automated segmentation algorithms. This work quantified the accuracy of organ dose estimates obtained by an automated segmentation algorithm. We hypothesized that the autosegmentation algorithm is sufficiently accurate to provide organ dose estimates, since small errors delineating organ boundaries will have minimal effect when computing mean organ dose. A leave-one-out validation study of the automated algorithm was performed with 20 head-neck CT scans expertly segmented into nine regions. Mean organ doses of the automatically and expertly segmented regions were computed from Monte Carlo-generated dose maps and compared. The automated segmentation algorithm estimated the mean organ dose to be within 10% of the expert segmentation for regions other than the spinal canal, with the median error for each organ region below 2%. In the spinal canal region, the median error was [Formula: see text], with a maximum absolute error of 28% for the single-atlas approach and 11% for the multiatlas approach. The results demonstrate that the automated segmentation algorithm can provide accurate organ dose estimates despite some segmentation errors.

  7. Accuracy of patient-specific organ dose estimates obtained using an automated image segmentation algorithm

    PubMed Central

    Schmidt, Taly Gilat; Wang, Adam S.; Coradi, Thomas; Haas, Benjamin; Star-Lack, Josh

    2016-01-01

    Abstract. The overall goal of this work is to develop a rapid, accurate, and automated software tool to estimate patient-specific organ doses from computed tomography (CT) scans using simulations to generate dose maps combined with automated segmentation algorithms. This work quantified the accuracy of organ dose estimates obtained by an automated segmentation algorithm. We hypothesized that the autosegmentation algorithm is sufficiently accurate to provide organ dose estimates, since small errors delineating organ boundaries will have minimal effect when computing mean organ dose. A leave-one-out validation study of the automated algorithm was performed with 20 head-neck CT scans expertly segmented into nine regions. Mean organ doses of the automatically and expertly segmented regions were computed from Monte Carlo-generated dose maps and compared. The automated segmentation algorithm estimated the mean organ dose to be within 10% of the expert segmentation for regions other than the spinal canal, with the median error for each organ region below 2%. In the spinal canal region, the median error was −7%, with a maximum absolute error of 28% for the single-atlas approach and 11% for the multiatlas approach. The results demonstrate that the automated segmentation algorithm can provide accurate organ dose estimates despite some segmentation errors. PMID:27921070

  8. Pigeons exhibit higher accuracy for chosen memory tests than for forced memory tests in duration matching-to-sample.

    PubMed

    Adams, Allison; Santi, Angelo

    2011-03-01

    Following training to match 2- and 8-sec durations of feederlight to red and green comparisons with a 0-sec baseline delay, pigeons were allowed to choose to take a memory test or to escape the memory test. The effects of sample omission, increases in retention interval, and variation in trial spacing on selection of the escape option and accuracy were studied. During initial testing, escaping the test did not increase as the task became more difficult, and there was no difference in accuracy between chosen and forced memory tests. However, with extended training, accuracy for chosen tests was significantly greater than for forced tests. In addition, two pigeons exhibited higher accuracy on chosen tests than on forced tests at the short retention interval and greater escape rates at the long retention interval. These results have not been obtained in previous studies with pigeons when the choice to take the test or to escape the test is given before test stimuli are presented. It appears that task-specific methodological factors may determine whether a particular species will exhibit the two behavioral effects that were initially proposed as potentially indicative of metacognition.

  9. Influence of non-level walking on pedometer accuracy.

    PubMed

    Leicht, Anthony S; Crowther, Robert G

    2009-05-01

    The YAMAX Digiwalker pedometer has been previously confirmed as a valid and reliable monitor during level walking, however, little is known about its accuracy during non-level walking activities or between genders. Subsequently, this study examined the influence of non-level walking and gender on pedometer accuracy. Forty-six healthy adults completed 3-min bouts of treadmill walking at their normal walking pace during 11 inclines (0-10%) while another 123 healthy adults completed walking up and down 47 stairs. During walking, participants wore a YAMAX Digiwalker SW-700 pedometer with the number of steps taken and registered by the pedometer recorded. Pedometer difference (steps registered-steps taken), net error (% of steps taken), absolute error (absolute % of steps taken) and gender were examined by repeated measures two-way ANOVA and Tukey's post hoc tests. During incline walking, pedometer accuracy indices were similar between inclines and gender except for a significantly greater step difference (-7+/-5 steps vs. 1+/-4 steps) and net error (-2.4+/-1.8% for 9% vs. 0.4+/-1.2% for 2%). Step difference and net error were significantly greater during stair descent compared to stair ascent while absolute error was significantly greater during stair ascent compared to stair descent. The current study demonstrated that the YAMAX Digiwalker SW-700 pedometer exhibited good accuracy during incline walking up to 10% while it overestimated steps taken during stair ascent/descent with greater overestimation during stair descent. Stair walking activity should be documented in field studies as the YAMAX Digiwalker SW-700 pedometer overestimates this activity type.

  10. Analysis of spatial distribution of land cover maps accuracy

    NASA Astrophysics Data System (ADS)

    Khatami, R.; Mountrakis, G.; Stehman, S. V.

    2017-12-01

    Land cover maps have become one of the most important products of remote sensing science. However, classification errors will exist in any classified map and affect the reliability of subsequent map usage. Moreover, classification accuracy often varies over different regions of a classified map. These variations of accuracy will affect the reliability of subsequent analyses of different regions based on the classified maps. The traditional approach of map accuracy assessment based on an error matrix does not capture the spatial variation in classification accuracy. Here, per-pixel accuracy prediction methods are proposed based on interpolating accuracy values from a test sample to produce wall-to-wall accuracy maps. Different accuracy prediction methods were developed based on four factors: predictive domain (spatial versus spectral), interpolation function (constant, linear, Gaussian, and logistic), incorporation of class information (interpolating each class separately versus grouping them together), and sample size. Incorporation of spectral domain as explanatory feature spaces of classification accuracy interpolation was done for the first time in this research. Performance of the prediction methods was evaluated using 26 test blocks, with 10 km × 10 km dimensions, dispersed throughout the United States. The performance of the predictions was evaluated using the area under the curve (AUC) of the receiver operating characteristic. Relative to existing accuracy prediction methods, our proposed methods resulted in improvements of AUC of 0.15 or greater. Evaluation of the four factors comprising the accuracy prediction methods demonstrated that: i) interpolations should be done separately for each class instead of grouping all classes together; ii) if an all-classes approach is used, the spectral domain will result in substantially greater AUC than the spatial domain; iii) for the smaller sample size and per-class predictions, the spectral and spatial domain

  11. Accuracy of Urine Color to Detect Equal to or Greater Than 2% Body Mass Loss in Men.

    PubMed

    McKenzie, Amy L; Muñoz, Colleen X; Armstrong, Lawrence E

    2015-12-01

    Clinicians and athletes can benefit from field-expedient measurement tools, such as urine color, to assess hydration state; however, the diagnostic efficacy of this tool has not been established. To determine the diagnostic accuracy of urine color assessment to distinguish a hypohydrated state (≥2% body mass loss [BML]) from a euhydrated state (<2% BML) after exercise in a hot environment. Controlled laboratory study. Environmental chamber in a laboratory. Twenty-two healthy men (age = 22 ± 3 years, height = 180.4 ± 8.7 cm, mass = 77.9 ± 12.8 kg, body fat = 10.6% ± 4.6%). Participants cycled at 68% ± 6% of their maximal heart rates in a hot environment (36°C ± 1°C) for 5 hours or until 5% BML was achieved. At the point of each 1% BML, we assessed urine color. Diagnostic efficacy of urine color was assessed using receiver operating characteristic curve analysis, sensitivity, specificity, and likelihood ratios. Urine color was useful as a diagnostic tool to identify hypohydration after exercise in the heat (area under the curve = 0.951, standard error = 0.022; P < .001). A urine color of 5 or greater identified BML ≥2% with 88.9% sensitivity and 84.8% specificity (positive likelihood ratio = 5.87, negative likelihood ratio = 0.13). Under the conditions of acute dehydration due to exercise in a hot environment, urine color assessment can be a valid, practical, inexpensive tool for assessing hydration status. Researchers should examine the utility of urine color to identify a hypohydrated state under different BML conditions.

  12. Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter

    PubMed Central

    Chung, Phil Hyun; Kang, Suk; Kim, Jong Pil; Kim, Young Sung; Back, In Hwa; Eom, Kyeong Soo

    2016-01-01

    Purpose Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. Materials and Methods This study involved 23 cases of greater trochanteric fractures as diagnosed using plain radiographs from January 2004 to July 2013. Until January 2008, 9 cases were examined with 3D-CT only, while 14 cases were screened with both 3D-CT and MRI scans. We analyzed diagnostic accuracy and treatment results following 3D-CT and MRI scanning. Results Nine cases that underwent 3D-CT only were diagnosed with isolated greater trochanteric fractures without occult intertrochanteric fractures. Of these, a patient with displacement received surgical treatment. Of the 14 patients screened using both CT and MRI, 13 were diagnosed with occult intertrochanteric fractures. Of these, 11 were treated with surgical intervention and 2 with conservative management. Conclusion Three-dimensional CT has very low diagnostic accuracy in diagnosing occult intertrochanteric fractures. For this reason, MRI is recommended to confirm a suspected occult intertrochanteric fracture and to determine the most appropriate mode of treatment. PMID:27536653

  13. A Study of the dimensional accuracy obtained by low cost 3D printing for possible application in medicine

    NASA Astrophysics Data System (ADS)

    Kitsakis, K.; Alabey, P.; Kechagias, J.; Vaxevanidis, N.

    2016-11-01

    Low cost 3D printing' is a terminology that referred to the fused filament fabrication (FFF) technique, which constructs physical prototypes, by depositing material layer by layer using a thermal nozzle head. Nowadays, 3D printing is widely used in medical applications such as tissue engineering as well as supporting tool in diagnosis and treatment in Neurosurgery, Orthopedic and Dental-Cranio-Maxillo-Facial surgery. 3D CAD medical models are usually obtained by MRI or CT scans and then are sent to a 3D printer for physical model creation. The present paper is focused on a brief overview of benefits and limitations of 3D printing applications in the field of medicine as well as on a dimensional accuracy study of low-cost 3D printing technique.

  14. Consider the source: Children link the accuracy of text-based sources to the accuracy of the author.

    PubMed

    Vanderbilt, Kimberly E; Ochoa, Karlena D; Heilbrun, Jayd

    2018-05-06

    The present research investigated whether young children link the accuracy of text-based information to the accuracy of its author. Across three experiments, three- and four-year-olds (N = 231) received information about object labels from accurate and inaccurate sources who provided information both in text and verbally. Of primary interest was whether young children would selectively rely on information provided by more accurate sources, regardless of the form in which the information was communicated. Experiment 1 tested children's trust in text-based information (e.g., books) written by an author with a history of either accurate or inaccurate verbal testimony and found that children showed greater trust in books written by accurate authors. Experiment 2 replicated the findings of Experiment 1 and extended them by showing that children's selective trust in more accurate text-based sources was not dependent on experience trusting or distrusting the author's verbal testimony. Experiment 3 investigated this understanding in reverse by testing children's trust in verbal testimony communicated by an individual who had authored either accurate or inaccurate text-based information. Experiment 3 revealed that children showed greater trust in individuals who had authored accurate rather than inaccurate books. Experiment 3 also demonstrated that children used the accuracy of text-based sources to make inferences about the mental states of the authors. Taken together, these results suggest children do indeed link the reliability of text-based sources to the reliability of the author. Statement of Contribution Existing knowledge Children use sources' prior accuracy to predict future accuracy in face-to-face verbal interactions. Children who are just learning to read show increased trust in text bases (vs. verbal) information. It is unknown whether children consider authors' prior accuracy when judging the accuracy of text-based information. New knowledge added by this

  15. Concept Mapping Improves Metacomprehension Accuracy among 7th Graders

    ERIC Educational Resources Information Center

    Redford, Joshua S.; Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.

    2012-01-01

    Two experiments explored concept map construction as a useful intervention to improve metacomprehension accuracy among 7th grade students. In the first experiment, metacomprehension was marginally better for a concept mapping group than for a rereading group. In the second experiment, metacomprehension accuracy was significantly greater for a…

  16. Accuracy investigation of phthalate metabolite standards.

    PubMed

    Langlois, Éric; Leblanc, Alain; Simard, Yves; Thellen, Claude

    2012-05-01

    Phthalates are ubiquitous compounds whose metabolites are usually determined in urine for biomonitoring studies. Following suspect and unexplained results from our laboratory in an external quality-assessment scheme, we investigated the accuracy of all phthalate metabolite standards in our possession by comparing them with those of several suppliers. Our findings suggest that commercial phthalate metabolite certified solutions are not always accurate and that lot-to-lot discrepancies significantly affect the accuracy of the results obtained with several of these standards. These observations indicate that the reliability of the results obtained from different lots of standards is not equal, which reduces the possibility of intra-laboratory and inter-laboratory comparisons of results. However, agreements of accuracy have been observed for a majority of neat standards obtained from different suppliers, which indicates that a solution to this issue is available. Data accuracy of phthalate metabolites should be of concern for laboratories performing phthalate metabolite analysis because of the standards used. The results of our investigation are presented from the perspective that laboratories performing phthalate metabolite analysis can obtain accurate and comparable results in the future. Our findings will contribute to improving the quality of future phthalate metabolite analyses and will affect the interpretation of past results.

  17. Accuracy of Carotid Duplex Criteria in Diagnosis of Significant Carotid Stenosis in Asian Patients.

    PubMed

    Dharmasaroja, Pornpatr A; Uransilp, Nattaphol; Watcharakorn, Arvemas; Piyabhan, Pritsana

    2018-03-01

    Extracranial carotid stenosis can be diagnosed by velocity criteria of carotid duplex. Whether they are accurately applied to define severity of internal carotid artery (ICA) stenosis in Asian patients needs to be proved. The purpose of this study was to evaluate the accuracy of 2 carotid duplex velocity criteria in defining significant carotid stenosis. Carotid duplex studies and magnetic resonance angiography were reviewed. Criteria 1 was recommended by the Society of Radiologists in Ultrasound; moderate stenosis (50%-69%): peak systolic velocity (PSV) 125-230 cm/s, diastolic velocity (DV) 40-100 cm/s; severe stenosis (>70%): PSV greater than 230 cm/s, DV greater than 100 cm/s. Criteria 2 used PSV greater than 140 cm/s, DV less than 110 cm/s to define moderate stenosis (50%-75%) and PSV greater than 140 cm/s, DV greater than 110 cm/s for severe stenosis (76%-95%). A total of 854 ICA segments were reviewed. There was moderate stenosis in 72 ICAs, severe stenosis in 50 ICAs, and occlusion in 78 ICAs. Criteria 2 had slightly lower sensitivity, whereas higher specificity and accuracy than criteria 1 were observed in detecting moderate stenosis (criteria 1: sensitivity 95%, specificity 83%, accuracy 84%; criteria 2: sensitivity 92%, specificity 92%, and accuracy 92%). However, in detection of severe ICA stenosis, no significant difference in sensitivity, specificity, and accuracy was found (criteria 1: sensitivity 82%, specificity 99.57%, accuracy 98%; criteria 2: sensitivity 86%, specificity 99.68%, and accuracy 99%). In the subgroup of moderate stenosis, the criteria using ICA PSV greater than 140 cm/s had higher specificity and accuracy than the criteria using ICA PSV 125-230 cm/s. However, there was no significant difference in detection of severe stenosis or occlusion of ICA. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  18. Discrimination in measures of knowledge monitoring accuracy

    PubMed Central

    Was, Christopher A.

    2014-01-01

    Knowledge monitoring predicts academic outcomes in many contexts. However, measures of knowledge monitoring accuracy are often incomplete. In the current study, a measure of students’ ability to discriminate known from unknown information as a component of knowledge monitoring was considered. Undergraduate students’ knowledge monitoring accuracy was assessed and used to predict final exam scores in a specific course. It was found that gamma, a measure commonly used as the measure of knowledge monitoring accuracy, accounted for a small, but significant amount of variance in academic performance whereas the discrimination and bias indexes combined to account for a greater amount of variance in academic performance. PMID:25339979

  19. Alzheimer's disease and memory-monitoring impairment: Alzheimer's patients show a monitoring deficit that is greater than their accuracy deficit.

    PubMed

    Dodson, Chad S; Spaniol, Maggie; O'Connor, Maureen K; Deason, Rebecca G; Ally, Brandon A; Budson, Andrew E

    2011-07-01

    We assessed the ability of two groups of patients with mild Alzheimer's disease (AD) and two groups of older adults to monitor the likely accuracy of recognition judgments and source identification judgments about who spoke something earlier. Alzheimer's patients showed worse performance on both memory judgments and were less able to monitor with confidence ratings the likely accuracy of both kinds of memory judgments, as compared to a group of older adults who experienced the identical study and test conditions. Critically, however, when memory performance was made comparable between the AD patients and the older adults (e.g., by giving AD patients extra exposures to the study materials), AD patients were still greatly impaired at monitoring the likely accuracy of their recognition and source judgments. This result indicates that the monitoring impairment in AD patients is actually worse than their memory impairment, as otherwise there would have been no differences between the two groups in monitoring performance when there were no differences in accuracy. We discuss the brain correlates of this memory-monitoring deficit and also propose a Remembrance-Evaluation model of memory-monitoring. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Greater Omental Milky Spot Examination for Diagnosis of Peritoneal Metastasis in Gastric Cancer Patients.

    PubMed

    Zhang, Xinming; Liu, Xin; Sun, Fengbo; Li, Shouchuan; Gao, Wei; Wang, Ye

    2017-02-01

    To evaluate the diagnostic value of cytological greater omental milky spot examination for the diagnosis of peritoneal metastasis in gastric cancer patients. A total of 136 patients diagnosed with gastric cancer and without distant metastasis were enrolled in our study. All patients underwent laparoscopy and CH40 suspension liquid dye of peritoneal lymph nodes preoperatively as well as ascites or peritoneal lavage fluid collections and excisions of marked greater omental milky spot tissues perioperatively. According to the laparoscopic results, the patients were divided into T1-T2 stage (n = 56) without and into T3-T4 stage (n = 80) with tumor invasion into the serosal layer. Among the T1-T2-stage patients, tumor cells could be detected in peritoneal lavage fluids in 2 cases, whereas with greater omental milky spot examination, peritoneal metastasis was detected in 8 cases. Among the 80 cases in the T3-T4 stage, tumor cells could be detected in 28 cases via peritoneal lavage cytology and in 43 cases by greater omental milky spot examinations, and 4 cases had cancer cell infiltration also in nonmilky spot omental areas. The statistical analysis showed that the staging accuracy rate of exfoliative cytology examination was superior to that of the laparoscopic exploration (P < .05), but its sensitivity was significantly lower than that obtained with cytological greater omental milky spot examinations (P < .05). The laparoscopic exploration could make a preliminary diagnosis of peritoneal metastasis via serosal layer invasion detection. For further analyses, cytological examinations of greater omental milky spots were more sensitive than exfoliative cytology.

  1. Intestinal Parasite Infections and Accuracy of Direct Thin and Thick Smear, Formol-Ether Sedimentation, Centrifugal Flotation, and Mini-FLOTAC Techniques Among Patients with Gastrointestinal Tract Disorders from the Greater Cairo Region, Egypt

    PubMed Central

    Hussein, Atef H.; Rashed, Samia M.; El-Hayawan, Ibrahim A.; Aly, Nagwa S. M.; Abou Ouf, Eman A.; Ali, Amira T.

    2017-01-01

    The aim of the present study was to assess the frequency of intestinal parasitic infection among patients with gastrointestinal tract disorders from the Greater Cairo region, Egypt. In addition, a comparison was made of the accuracy of direct thin and thick smear, formol-ether sedimentation (FEC), centrifugal flotation (CF), and mini-FLOTAC techniques in the diagnosis of infection. Out of 100 patients, the overall prevalence of parasitic infection was 51%. Only 6% had dual infection. Giardia lamblia was the most common parasite (26%), followed by Hymenolepis nana (20%), Entamoeba coli (8%), and Enterobius vermicularis (3%). Except the statistically significant association between E. vermicularis infection and perianal itching and insomnia (P < 0.001), age, gender, and complaints of the examined individuals had no association with prevalence of parasitic infection. Both FEC and CF were equally the most accurate techniques (accuracy = 98.2%, confidence interval [CI] = 0.95–1.0, and κ index = 0.962), whereas the Kato-Katz method was the least accurate (accuracy = 67.5%, CI = 0.57–0.78, and κ index = 0.333). However, mini-FLOTAC-ZnSO4 was the most accurate for diagnosis of helminthic infection, and FEC was more accurate for diagnosis of protozoal infection (accuracy = 100%, CI = 1.0–1.0, and κ index = 1). PMID:28093543

  2. Phase noise in pulsed Doppler lidar and limitations on achievable single-shot velocity accuracy

    NASA Technical Reports Server (NTRS)

    Mcnicholl, P.; Alejandro, S.

    1992-01-01

    The smaller sampling volumes afforded by Doppler lidars compared to radars allows for spatial resolutions at and below some sheer and turbulence wind structure scale sizes. This has brought new emphasis on achieving the optimum product of wind velocity and range resolutions. Several recent studies have considered the effects of amplitude noise, reduction algorithms, and possible hardware related signal artifacts on obtainable velocity accuracy. We discuss here the limitation on this accuracy resulting from the incoherent nature and finite temporal extent of backscatter from aerosols. For a lidar return from a hard (or slab) target, the phase of the intermediate frequency (IF) signal is random and the total return energy fluctuates from shot to shot due to speckle; however, the offset from the transmitted frequency is determinable with an accuracy subject only to instrumental effects and the signal to noise ratio (SNR), the noise being determined by the LO power in the shot noise limited regime. This is not the case for a return from a media extending over a range on the order of or greater than the spatial extent of the transmitted pulse, such as from atmospheric aerosols. In this case, the phase of the IF signal will exhibit a temporal random walk like behavior. It will be uncorrelated over times greater than the pulse duration as the transmitted pulse samples non-overlapping volumes of scattering centers. Frequency analysis of the IF signal in a window similar to the transmitted pulse envelope will therefore show shot-to-shot frequency deviations on the order of the inverse pulse duration reflecting the random phase rate variations. Like speckle, these deviations arise from the incoherent nature of the scattering process and diminish if the IF signal is averaged over times greater than a single range resolution cell (here the pulse duration). Apart from limiting the high SNR performance of a Doppler lidar, this shot-to-shot variance in velocity estimates has a

  3. Estimating the Accuracy of the Chedoke-McMaster Stroke Assessment Predictive Equations for Stroke Rehabilitation.

    PubMed

    Dang, Mia; Ramsaran, Kalinda D; Street, Melissa E; Syed, S Noreen; Barclay-Goddard, Ruth; Stratford, Paul W; Miller, Patricia A

    2011-01-01

    To estimate the predictive accuracy and clinical usefulness of the Chedoke-McMaster Stroke Assessment (CMSA) predictive equations. A longitudinal prognostic study using historical data obtained from 104 patients admitted post cerebrovascular accident was undertaken. Data were abstracted for all patients undergoing rehabilitation post stroke who also had documented admission and discharge CMSA scores. Published predictive equations were used to determine predicted outcomes. To determine the accuracy and clinical usefulness of the predictive model, shrinkage coefficients and predictions with 95% confidence bands were calculated. Complete data were available for 74 patients with a mean age of 65.3±12.4 years. The shrinkage values for the six Impairment Inventory (II) dimensions varied from -0.05 to 0.09; the shrinkage value for the Activity Inventory (AI) was 0.21. The error associated with predictive values was greater than ±1.5 stages for the II dimensions and greater than ±24 points for the AI. This study shows that the large error associated with the predictions (as defined by the confidence band) for the CMSA II and AI limits their clinical usefulness as a predictive measure. Further research to establish predictive models using alternative statistical procedures is warranted.

  4. Developmental Changes in Cross-Situational Word Learning: The Inverse Effect of Initial Accuracy

    ERIC Educational Resources Information Center

    Fitneva, Stanka A.; Christiansen, Morten H.

    2017-01-01

    Intuitively, the accuracy of initial word-referent mappings should be positively correlated with the outcome of learning. Yet recent evidence suggests an inverse effect of initial accuracy in adults, whereby greater accuracy of initial mappings is associated with poorer outcomes in a cross-situational learning task. Here, we examine the impact of…

  5. Accuracy of patient specific organ-dose estimates obtained using an automated image segmentation algorithm

    NASA Astrophysics Data System (ADS)

    Gilat-Schmidt, Taly; Wang, Adam; Coradi, Thomas; Haas, Benjamin; Star-Lack, Josh

    2016-03-01

    The overall goal of this work is to develop a rapid, accurate and fully automated software tool to estimate patient-specific organ doses from computed tomography (CT) scans using a deterministic Boltzmann Transport Equation solver and automated CT segmentation algorithms. This work quantified the accuracy of organ dose estimates obtained by an automated segmentation algorithm. The investigated algorithm uses a combination of feature-based and atlas-based methods. A multiatlas approach was also investigated. We hypothesize that the auto-segmentation algorithm is sufficiently accurate to provide organ dose estimates since random errors at the organ boundaries will average out when computing the total organ dose. To test this hypothesis, twenty head-neck CT scans were expertly segmented into nine regions. A leave-one-out validation study was performed, where every case was automatically segmented with each of the remaining cases used as the expert atlas, resulting in nineteen automated segmentations for each of the twenty datasets. The segmented regions were applied to gold-standard Monte Carlo dose maps to estimate mean and peak organ doses. The results demonstrated that the fully automated segmentation algorithm estimated the mean organ dose to within 10% of the expert segmentation for regions other than the spinal canal, with median error for each organ region below 2%. In the spinal canal region, the median error was 7% across all data sets and atlases, with a maximum error of 20%. The error in peak organ dose was below 10% for all regions, with a median error below 4% for all organ regions. The multiple-case atlas reduced the variation in the dose estimates and additional improvements may be possible with more robust multi-atlas approaches. Overall, the results support potential feasibility of an automated segmentation algorithm to provide accurate organ dose estimates.

  6. Dental measurements and Bolton index reliability and accuracy obtained from 2D digital, 3D segmented CBCT, and 3d intraoral laser scanner

    PubMed Central

    San José, Verónica; Bellot-Arcís, Carlos; Tarazona, Beatriz; Zamora, Natalia; O Lagravère, Manuel

    2017-01-01

    Background To compare the reliability and accuracy of direct and indirect dental measurements derived from two types of 3D virtual models: generated by intraoral laser scanning (ILS) and segmented cone beam computed tomography (CBCT), comparing these with a 2D digital model. Material and Methods One hundred patients were selected. All patients’ records included initial plaster models, an intraoral scan and a CBCT. Patients´ dental arches were scanned with the iTero® intraoral scanner while the CBCTs were segmented to create three-dimensional models. To obtain 2D digital models, plaster models were scanned using a conventional 2D scanner. When digital models had been obtained using these three methods, direct dental measurements were measured and indirect measurements were calculated. Differences between methods were assessed by means of paired t-tests and regression models. Intra and inter-observer error were analyzed using Dahlberg´s d and coefficients of variation. Results Intraobserver and interobserver error for the ILS model was less than 0.44 mm while for segmented CBCT models, the error was less than 0.97 mm. ILS models provided statistically and clinically acceptable accuracy for all dental measurements, while CBCT models showed a tendency to underestimate measurements in the lower arch, although within the limits of clinical acceptability. Conclusions ILS and CBCT segmented models are both reliable and accurate for dental measurements. Integration of ILS with CBCT scans would get dental and skeletal information altogether. Key words:CBCT, intraoral laser scanner, 2D digital models, 3D models, dental measurements, reliability. PMID:29410764

  7. Throwing speed and accuracy in baseball and cricket players.

    PubMed

    Freeston, Jonathan; Rooney, Kieron

    2014-06-01

    Throwing speed and accuracy are both critical to sports performance but cannot be optimized simultaneously. This speed-accuracy trade-off (SATO) is evident across a number of throwing groups but remains poorly understood. The goal was to describe the SATO in baseball and cricket players and determine the speed that optimizes accuracy. 20 grade-level baseball and cricket players performed 10 throws at 80% and 100% of maximal throwing speed (MTS) toward a cricket stump. Baseball players then performed a further 10 throws at 70%, 80%, 90%, and 100% of MTS toward a circular target. Baseball players threw faster with greater accuracy than cricket players at both speeds. Both groups demonstrated a significant SATO as vertical error increased with increases in speed; the trade-off was worse for cricketers than baseball players. Accuracy was optimized at 70% of MTS for baseballers. Throwing athletes should decrease speed when accuracy is critical. Cricket players could adopt baseball-training practices to improve throwing performance.

  8. Optimizing Tsunami Forecast Model Accuracy

    NASA Astrophysics Data System (ADS)

    Whitmore, P.; Nyland, D. L.; Huang, P. Y.

    2015-12-01

    Recent tsunamis provide a means to determine the accuracy that can be expected of real-time tsunami forecast models. Forecast accuracy using two different tsunami forecast models are compared for seven events since 2006 based on both real-time application and optimized, after-the-fact "forecasts". Lessons learned by comparing the forecast accuracy determined during an event to modified applications of the models after-the-fact provide improved methods for real-time forecasting for future events. Variables such as source definition, data assimilation, and model scaling factors are examined to optimize forecast accuracy. Forecast accuracy is also compared for direct forward modeling based on earthquake source parameters versus accuracy obtained by assimilating sea level data into the forecast model. Results show that including assimilated sea level data into the models increases accuracy by approximately 15% for the events examined.

  9. Accuracy of pulse oximetry in children.

    PubMed

    Ross, Patrick A; Newth, Christopher J L; Khemani, Robinder G

    2014-01-01

    For children with cyanotic congenital heart disease or acute hypoxemic respiratory failure, providers frequently make decisions based on pulse oximetry, in the absence of an arterial blood gas. The study objective was to measure the accuracy of pulse oximetry in the saturations from pulse oximetry (SpO2) range of 65% to 97%. This institutional review board-approved prospective, multicenter observational study in 5 PICUs included 225 mechanically ventilated children with an arterial catheter. With each arterial blood gas sample, SpO2 from pulse oximetry and arterial oxygen saturations from CO-oximetry (SaO2) were simultaneously obtained if the SpO2 was ≤ 97%. The lowest SpO2 obtained in the study was 65%. In the range of SpO2 65% to 97%, 1980 simultaneous values for SpO2 and SaO2 were obtained. The bias (SpO2 - SaO2) varied through the range of SpO2 values. The bias was greatest in the SpO2 range 81% to 85% (336 samples, median 6%, mean 6.6%, accuracy root mean squared 9.1%). SpO2 measurements were close to SaO2 in the SpO2 range 91% to 97% (901 samples, median 1%, mean 1.5%, accuracy root mean squared 4.2%). Previous studies on pulse oximeter accuracy in children present a single number for bias. This study identified that the accuracy of pulse oximetry varies significantly as a function of the SpO2 range. Saturations measured by pulse oximetry on average overestimate SaO2 from CO-oximetry in the SpO2 range of 76% to 90%. Better pulse oximetry algorithms are needed for accurate assessment of children with saturations in the hypoxemic range.

  10. Estimating the Accuracy of the Chedoke–McMaster Stroke Assessment Predictive Equations for Stroke Rehabilitation

    PubMed Central

    Dang, Mia; Ramsaran, Kalinda D.; Street, Melissa E.; Syed, S. Noreen; Barclay-Goddard, Ruth; Miller, Patricia A.

    2011-01-01

    ABSTRACT Purpose: To estimate the predictive accuracy and clinical usefulness of the Chedoke–McMaster Stroke Assessment (CMSA) predictive equations. Method: A longitudinal prognostic study using historical data obtained from 104 patients admitted post cerebrovascular accident was undertaken. Data were abstracted for all patients undergoing rehabilitation post stroke who also had documented admission and discharge CMSA scores. Published predictive equations were used to determine predicted outcomes. To determine the accuracy and clinical usefulness of the predictive model, shrinkage coefficients and predictions with 95% confidence bands were calculated. Results: Complete data were available for 74 patients with a mean age of 65.3±12.4 years. The shrinkage values for the six Impairment Inventory (II) dimensions varied from −0.05 to 0.09; the shrinkage value for the Activity Inventory (AI) was 0.21. The error associated with predictive values was greater than ±1.5 stages for the II dimensions and greater than ±24 points for the AI. Conclusions: This study shows that the large error associated with the predictions (as defined by the confidence band) for the CMSA II and AI limits their clinical usefulness as a predictive measure. Further research to establish predictive models using alternative statistical procedures is warranted. PMID:22654239

  11. Accuracy of axial length measurements obtained by optical biometry and acoustic biometry in rhegmatogenous retinal detachment: a prospective study.

    PubMed

    Pongsachareonnont, Pear; Tangjanyatam, Sagol

    2018-01-01

    We compared the accuracy of axial length (AL) measurement obtained by optical biometry with that obtained by acoustic biometry in eyes with rhegmatogenous retinal detachment (RRD). This prospective descriptive analytic study measured the AL of eyes with RRD preoperatively and 3 months postoperatively using optical biometry (intraocular lens [IOL] master group) and acoustic biometry (immersion A-scan group). Preoperative and postoperative measurements were compared by paired t -test. The agreement between preoperative and postoperative measurements was analyzed using a Bland-Altman plot. Subgroup analysis of macular involvement status was performed. Twenty-seven eyes were analyzed in this study. The mean AL in the IOL master group was 23.58±0.97 mm preoperatively and 24.17±1.16 mm postoperatively; the mean difference was -0.59±0.90 mm ( P = 0.007). The mean AL in the immersion A-scan group was 24.29±1.59 mm preoperatively and 24.27±1.69 mm postoperatively; the mean difference was 0.02±0.48 mm ( P = 0.827). Bland-Altman analysis revealed disagreement between preoperative and postoperative AL measurements in both techniques. In subgroup analysis of macula with RRD, there were significant differences between preoperative and postoperative AL measurements in the IOL master group ( P = 0.014). Significant underestimation of AL measurement was observed when using the IOL master in eyes with RRD with macular involvement, which could affect IOL power selection.

  12. Effects of cognitive training on change in accuracy in inductive reasoning ability.

    PubMed

    Boron, Julie Blaskewicz; Turiano, Nicholas A; Willis, Sherry L; Schaie, K Warner

    2007-05-01

    We investigated cognitive training effects on accuracy and number of items attempted in inductive reasoning performance in a sample of 335 older participants (M = 72.78 years) from the Seattle Longitudinal Study. We assessed the impact of individual characteristics, including chronic disease. The reasoning training group showed significantly greater gain in accuracy and number of attempted items than did the comparison group; gain was primarily due to enhanced accuracy. Reasoning training effects involved a complex interaction of gender, prior cognitive status, and chronic disease. Women with prior decline on reasoning but no heart disease showed the greatest accuracy increase. In addition, stable reasoning-trained women with heart disease demonstrated significant accuracy gain. Comorbidity was associated with less change in accuracy. The results support the effectiveness of cognitive training on improving the accuracy of reasoning performance.

  13. Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy.

    PubMed

    Zhao, Yi-Jiao; Xiong, Yu-Xue; Wang, Yong

    2017-01-01

    In this study, the practical accuracy (PA) of optical facial scanners for facial deformity patients in oral clinic was evaluated. Ten patients with a variety of facial deformities from oral clinical were included in the study. For each patient, a three-dimensional (3D) face model was acquired, via a high-accuracy industrial "line-laser" scanner (Faro), as the reference model and two test models were obtained, via a "stereophotography" (3dMD) and a "structured light" facial scanner (FaceScan) separately. Registration based on the iterative closest point (ICP) algorithm was executed to overlap the test models to reference models, and "3D error" as a new measurement indicator calculated by reverse engineering software (Geomagic Studio) was used to evaluate the 3D global and partial (upper, middle, and lower parts of face) PA of each facial scanner. The respective 3D accuracy of stereophotography and structured light facial scanners obtained for facial deformities was 0.58±0.11 mm and 0.57±0.07 mm. The 3D accuracy of different facial partitions was inconsistent; the middle face had the best performance. Although the PA of two facial scanners was lower than their nominal accuracy (NA), they all met the requirement for oral clinic use.

  14. Demystifying the Clinical Diagnosis of Greater Trochanteric Pain Syndrome in Women.

    PubMed

    Ganderton, Charlotte; Semciw, Adam; Cook, Jill; Pizzari, Tania

    2017-06-01

    To evaluate the diagnostic accuracy of 10 clinical tests that can be used in the diagnosis of greater trochanteric pain syndrome (GTPS) in women, and to compare these clinical tests to magnetic resonance imaging (MRI) findings. Twenty-eight participants with GTPS (49.5 ± 22.0 years) and 18 asymptomatic participants (mean age ± standard deviation [SD], 52.5 ± 22.8 years) were included. A blinded physiotherapist performed 10 pain provocation tests potentially diagnostic for GTPS-palpation of the greater trochanter, resisted external derotation test, modified resisted external derotation test, standard and modified Ober's tests, Patrick's or FABER test, resisted hip abduction, single-leg stance test, and the resisted hip internal rotation test. A sample of 16 symptomatic and 17 asymptomatic women undertook a hip MRI scan. Gluteal tendons were evaluated and categorized as no pathology, mild tendinosis, moderate tendinosis/partial tear, or full-thickness tear. Clinical test analyses show high specificity, high positive predictive value, low to moderate sensitivity, and negative predictive value for most clinical tests. All symptomatic and 88% of asymptomatic participants had pathological gluteal tendon changes on MRI, from mild tendinosis to full-thickness tear. The study found the Patrick's or FABER test, palpation of the greater trochanter, resisted hip abduction, and the resisted external derotation test to have the highest diagnostic test accuracy for GTPS. Tendon pathology on MRI is seen in both symptomatic and asymptomatic women.

  15. Proton-nucleus total inelastic cross sections - An empirical formula for E greater than 10 MeV

    NASA Technical Reports Server (NTRS)

    Letaw, J. R.; Silberberg, R.; Tsao, C. H.

    1983-01-01

    An empirical formula for the total inelastic cross section of protons on nuclei with charge greater than 1 is presented. The formula is valid with a varying degree of accuracy down to proton energies of 10 MeV. At high energies (equal to or greater than 2 GeV) the formula reproduces experimental data to within reported errors (about 2%).

  16. Evaluating the accuracy of SHAPE-directed RNA secondary structure predictions

    PubMed Central

    Sükösd, Zsuzsanna; Swenson, M. Shel; Kjems, Jørgen; Heitsch, Christine E.

    2013-01-01

    Recent advances in RNA structure determination include using data from high-throughput probing experiments to improve thermodynamic prediction accuracy. We evaluate the extent and nature of improvements in data-directed predictions for a diverse set of 16S/18S ribosomal sequences using a stochastic model of experimental SHAPE data. The average accuracy for 1000 data-directed predictions always improves over the original minimum free energy (MFE) structure. However, the amount of improvement varies with the sequence, exhibiting a correlation with MFE accuracy. Further analysis of this correlation shows that accurate MFE base pairs are typically preserved in a data-directed prediction, whereas inaccurate ones are not. Thus, the positive predictive value of common base pairs is consistently higher than the directed prediction accuracy. Finally, we confirm sequence dependencies in the directability of thermodynamic predictions and investigate the potential for greater accuracy improvements in the worst performing test sequence. PMID:23325843

  17. Utilization of Pharmacy Technicians to Increase the Accuracy of Patient Medication Histories Obtained in the Emergency Department

    PubMed Central

    Pisupati, Radhika; Nerenberg, Steven F.

    2016-01-01

    Purpose: The purpose of this study is to determine the accuracy of a pharmacy technician–collected medication history pilot program in the emergency department. This was completed by reviewing all elements of the technician activity by direct observation and by verifying the technician-collected medication list through a second phone call by a pharmacist to the outpatient pharmacy. Methods: This was a retrospective, single-center study conducted from March to April 2015. Four certified pharmacy technicians were trained by a postgraduate year 1 (PGY1) pharmacy practice resident on how to collect, verify, and accurately enter medication histories into the electronic medical record. Accuracy of pharmacy technician–collected medication histories was verified by a pharmacist through observation of their patient interviews, review of technician-completed medication history forms, and by contacting the patient's outpatient pharmacy. Results: The pharmacy technician–completed medication histories resulted in an absolute risk reduction of errors of 50% and a relative risk reduction of errors of 77% (p < .001) in comparison to medication histories collected by non-pharmacy personnel. Conclusion: With high accuracy rates, pharmacy technicians proved to be a valuable asset to the medication history process and can enhance patient safety during care transitions. The results of this study further support the Pharmacy Practice Model Initiative vision to advance the pharmacy technician role to improve the process of medication history taking and reconciliation within the health care system. PMID:27303094

  18. Assessment of accuracy and recognition of three-dimensional computerized forensic craniofacial reconstruction.

    PubMed

    Miranda, Geraldo Elias; Wilkinson, Caroline; Roughley, Mark; Beaini, Thiago Leite; Melani, Rodolfo Francisco Haltenhoff

    2018-01-01

    Facial reconstruction is a technique that aims to reproduce the individual facial characteristics based on interpretation of the skull, with the objective of recognition leading to identification. The aim of this paper was to evaluate the accuracy and recognition level of three-dimensional (3D) computerized forensic craniofacial reconstruction (CCFR) performed in a blind test on open-source software using computed tomography (CT) data from live subjects. Four CCFRs were produced by one of the researchers, who was provided with information concerning the age, sex, and ethnic group of each subject. The CCFRs were produced using Blender® with 3D models obtained from the CT data and templates from the MakeHuman® program. The evaluation of accuracy was carried out in CloudCompare, by geometric comparison of the CCFR to the subject 3D face model (obtained from the CT data). A recognition level was performed using the Picasa® recognition tool with a frontal standardized photography, images of the subject CT face model and the CCFR. Soft-tissue depth and nose, ears and mouth were based on published data, observing Brazilian facial parameters. The results were presented from all the points that form the CCFR model, with an average for each comparison between 63% and 74% with a distance -2.5 ≤ x ≤ 2.5 mm from the skin surface. The average distances were 1.66 to 0.33 mm and greater distances were observed around the eyes, cheeks, mental and zygomatic regions. Two of the four CCFRs were correctly matched by the Picasa® tool. Free software programs are capable of producing 3D CCFRs with plausible levels of accuracy and recognition and therefore indicate their value for use in forensic applications.

  19. Assessment of accuracy and recognition of three-dimensional computerized forensic craniofacial reconstruction

    PubMed Central

    Wilkinson, Caroline; Roughley, Mark; Beaini, Thiago Leite; Melani, Rodolfo Francisco Haltenhoff

    2018-01-01

    Facial reconstruction is a technique that aims to reproduce the individual facial characteristics based on interpretation of the skull, with the objective of recognition leading to identification. The aim of this paper was to evaluate the accuracy and recognition level of three-dimensional (3D) computerized forensic craniofacial reconstruction (CCFR) performed in a blind test on open-source software using computed tomography (CT) data from live subjects. Four CCFRs were produced by one of the researchers, who was provided with information concerning the age, sex, and ethnic group of each subject. The CCFRs were produced using Blender® with 3D models obtained from the CT data and templates from the MakeHuman® program. The evaluation of accuracy was carried out in CloudCompare, by geometric comparison of the CCFR to the subject 3D face model (obtained from the CT data). A recognition level was performed using the Picasa® recognition tool with a frontal standardized photography, images of the subject CT face model and the CCFR. Soft-tissue depth and nose, ears and mouth were based on published data, observing Brazilian facial parameters. The results were presented from all the points that form the CCFR model, with an average for each comparison between 63% and 74% with a distance -2.5 ≤ x ≤ 2.5 mm from the skin surface. The average distances were 1.66 to 0.33 mm and greater distances were observed around the eyes, cheeks, mental and zygomatic regions. Two of the four CCFRs were correctly matched by the Picasa® tool. Free software programs are capable of producing 3D CCFRs with plausible levels of accuracy and recognition and therefore indicate their value for use in forensic applications. PMID:29718983

  20. 10 CFR 72.11 - Completeness and accuracy of information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Completeness and accuracy of information. 72.11 Section 72.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  1. 10 CFR 72.11 - Completeness and accuracy of information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Completeness and accuracy of information. 72.11 Section 72.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  2. 10 CFR 72.11 - Completeness and accuracy of information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Completeness and accuracy of information. 72.11 Section 72.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  3. 10 CFR 72.11 - Completeness and accuracy of information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Completeness and accuracy of information. 72.11 Section 72.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  4. 10 CFR 72.11 - Completeness and accuracy of information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Completeness and accuracy of information. 72.11 Section 72.11 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  5. Accuracy of digital images in the detection of marginal microleakage: an in vitro study.

    PubMed

    Alvarenga, Fábio Augusto; Andrade, Marcelo Ferrarezi; Pinelli, Camila; Rastelli, Alessanda Nara; Victorino, Keli Regina; Loffredo, Leonor de

    2012-08-01

    To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study. Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI). The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99). Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.

  6. The neglected tool in the Bayesian ecologist's shed: a case study testing informative priors' effect on model accuracy

    PubMed Central

    Morris, William K; Vesk, Peter A; McCarthy, Michael A; Bunyavejchewin, Sarayudh; Baker, Patrick J

    2015-01-01

    Despite benefits for precision, ecologists rarely use informative priors. One reason that ecologists may prefer vague priors is the perception that informative priors reduce accuracy. To date, no ecological study has empirically evaluated data-derived informative priors' effects on precision and accuracy. To determine the impacts of priors, we evaluated mortality models for tree species using data from a forest dynamics plot in Thailand. Half the models used vague priors, and the remaining half had informative priors. We found precision was greater when using informative priors, but effects on accuracy were more variable. In some cases, prior information improved accuracy, while in others, it was reduced. On average, models with informative priors were no more or less accurate than models without. Our analyses provide a detailed case study on the simultaneous effect of prior information on precision and accuracy and demonstrate that when priors are specified appropriately, they lead to greater precision without systematically reducing model accuracy. PMID:25628867

  7. The neglected tool in the Bayesian ecologist's shed: a case study testing informative priors' effect on model accuracy.

    PubMed

    Morris, William K; Vesk, Peter A; McCarthy, Michael A; Bunyavejchewin, Sarayudh; Baker, Patrick J

    2015-01-01

    Despite benefits for precision, ecologists rarely use informative priors. One reason that ecologists may prefer vague priors is the perception that informative priors reduce accuracy. To date, no ecological study has empirically evaluated data-derived informative priors' effects on precision and accuracy. To determine the impacts of priors, we evaluated mortality models for tree species using data from a forest dynamics plot in Thailand. Half the models used vague priors, and the remaining half had informative priors. We found precision was greater when using informative priors, but effects on accuracy were more variable. In some cases, prior information improved accuracy, while in others, it was reduced. On average, models with informative priors were no more or less accurate than models without. Our analyses provide a detailed case study on the simultaneous effect of prior information on precision and accuracy and demonstrate that when priors are specified appropriately, they lead to greater precision without systematically reducing model accuracy.

  8. Accuracies of genomic breeding values in American Angus beef cattle using K-means clustering for cross-validation.

    PubMed

    Saatchi, Mahdi; McClure, Mathew C; McKay, Stephanie D; Rolf, Megan M; Kim, JaeWoo; Decker, Jared E; Taxis, Tasia M; Chapple, Richard H; Ramey, Holly R; Northcutt, Sally L; Bauck, Stewart; Woodward, Brent; Dekkers, Jack C M; Fernando, Rohan L; Schnabel, Robert D; Garrick, Dorian J; Taylor, Jeremy F

    2011-11-28

    Genomic selection is a recently developed technology that is beginning to revolutionize animal breeding. The objective of this study was to estimate marker effects to derive prediction equations for direct genomic values for 16 routinely recorded traits of American Angus beef cattle and quantify corresponding accuracies of prediction. Deregressed estimated breeding values were used as observations in a weighted analysis to derive direct genomic values for 3570 sires genotyped using the Illumina BovineSNP50 BeadChip. These bulls were clustered into five groups using K-means clustering on pedigree estimates of additive genetic relationships between animals, with the aim of increasing within-group and decreasing between-group relationships. All five combinations of four groups were used for model training, with cross-validation performed in the group not used in training. Bivariate animal models were used for each trait to estimate the genetic correlation between deregressed estimated breeding values and direct genomic values. Accuracies of direct genomic values ranged from 0.22 to 0.69 for the studied traits, with an average of 0.44. Predictions were more accurate when animals within the validation group were more closely related to animals in the training set. When training and validation sets were formed by random allocation, the accuracies of direct genomic values ranged from 0.38 to 0.85, with an average of 0.65, reflecting the greater relationship between animals in training and validation. The accuracies of direct genomic values obtained from training on older animals and validating in younger animals were intermediate to the accuracies obtained from K-means clustering and random clustering for most traits. The genetic correlation between deregressed estimated breeding values and direct genomic values ranged from 0.15 to 0.80 for the traits studied. These results suggest that genomic estimates of genetic merit can be produced in beef cattle at a young age but

  9. Accuracies of genomic breeding values in American Angus beef cattle using K-means clustering for cross-validation

    PubMed Central

    2011-01-01

    Background Genomic selection is a recently developed technology that is beginning to revolutionize animal breeding. The objective of this study was to estimate marker effects to derive prediction equations for direct genomic values for 16 routinely recorded traits of American Angus beef cattle and quantify corresponding accuracies of prediction. Methods Deregressed estimated breeding values were used as observations in a weighted analysis to derive direct genomic values for 3570 sires genotyped using the Illumina BovineSNP50 BeadChip. These bulls were clustered into five groups using K-means clustering on pedigree estimates of additive genetic relationships between animals, with the aim of increasing within-group and decreasing between-group relationships. All five combinations of four groups were used for model training, with cross-validation performed in the group not used in training. Bivariate animal models were used for each trait to estimate the genetic correlation between deregressed estimated breeding values and direct genomic values. Results Accuracies of direct genomic values ranged from 0.22 to 0.69 for the studied traits, with an average of 0.44. Predictions were more accurate when animals within the validation group were more closely related to animals in the training set. When training and validation sets were formed by random allocation, the accuracies of direct genomic values ranged from 0.38 to 0.85, with an average of 0.65, reflecting the greater relationship between animals in training and validation. The accuracies of direct genomic values obtained from training on older animals and validating in younger animals were intermediate to the accuracies obtained from K-means clustering and random clustering for most traits. The genetic correlation between deregressed estimated breeding values and direct genomic values ranged from 0.15 to 0.80 for the traits studied. Conclusions These results suggest that genomic estimates of genetic merit can be

  10. Research on effect of rough surface on FMCW laser radar range accuracy

    NASA Astrophysics Data System (ADS)

    Tao, Huirong

    2018-03-01

    The non-cooperative targets large scale measurement system based on frequency-modulated continuous-wave (FMCW) laser detection and ranging technology has broad application prospects. It is easy to automate measurement without cooperative targets. However, the complexity and diversity of the surface characteristics of the measured surface directly affects the measurement accuracy. First, the theoretical analysis of range accuracy for a FMCW laser radar was studied, the relationship between surface reflectivity and accuracy was obtained. Then, to verify the effect of surface reflectance for ranging accuracy, a standard tool ball and three standard roughness samples were measured within 7 m to 24 m. The uncertainty of each target was obtained. The results show that the measurement accuracy is found to increase as the surface reflectivity gets larger. Good agreements were obtained between theoretical analysis and measurements from rough surfaces. Otherwise, when the laser spot diameter is smaller than the surface correlation length, a multi-point averaged measurement can reduce the measurement uncertainty. The experimental results show that this method is feasible.

  11. Effect of black point on accuracy of LCD displays colorimetric characterization

    NASA Astrophysics Data System (ADS)

    Li, Tong; Xie, Kai; He, Nannan; Ye, Yushan

    2018-03-01

    Black point is the point at which RGB's single channel digital drive value is 0. Due to the problem of light leakage of liquid-crystal displays (LCDs), black point's luminance value is not 0, this phenomenon bring some errors to colorimetric characterization of LCDs, especially low luminance value driving greater sampling effect. This paper describes the characteristic accuracy of polynomial model method and the effect of black point on accuracy, the color difference accuracy is given. When considering the black point in the characteristics equation, the maximum color difference is 3.246, the maximum color difference than without considering the black points reduced by 2.36. The experimental results show that the accuracy of LCDs colorimetric characterization can be improved, if the effect of black point is eliminated properly.

  12. Factors affecting GEBV accuracy with single-step Bayesian models.

    PubMed

    Zhou, Lei; Mrode, Raphael; Zhang, Shengli; Zhang, Qin; Li, Bugao; Liu, Jian-Feng

    2018-01-01

    A single-step approach to obtain genomic prediction was first proposed in 2009. Many studies have investigated the components of GEBV accuracy in genomic selection. However, it is still unclear how the population structure and the relationships between training and validation populations influence GEBV accuracy in terms of single-step analysis. Here, we explored the components of GEBV accuracy in single-step Bayesian analysis with a simulation study. Three scenarios with various numbers of QTL (5, 50, and 500) were simulated. Three models were implemented to analyze the simulated data: single-step genomic best linear unbiased prediction (GBLUP; SSGBLUP), single-step BayesA (SS-BayesA), and single-step BayesB (SS-BayesB). According to our results, GEBV accuracy was influenced by the relationships between the training and validation populations more significantly for ungenotyped animals than for genotyped animals. SS-BayesA/BayesB showed an obvious advantage over SSGBLUP with the scenarios of 5 and 50 QTL. SS-BayesB model obtained the lowest accuracy with the 500 QTL in the simulation. SS-BayesA model was the most efficient and robust considering all QTL scenarios. Generally, both the relationships between training and validation populations and LD between markers and QTL contributed to GEBV accuracy in the single-step analysis, and the advantages of single-step Bayesian models were more apparent when the trait is controlled by fewer QTL.

  13. Accuracy of endoscopic intraoperative assessment of urologic stone size.

    PubMed

    Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L

    2014-05-01

    Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-value<0.01. The estimation of small stones (<4 mm) had a greater accuracy than large stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.

  14. A fast RCS accuracy assessment method for passive radar calibrators

    NASA Astrophysics Data System (ADS)

    Zhou, Yongsheng; Li, Chuanrong; Tang, Lingli; Ma, Lingling; Liu, QI

    2016-10-01

    In microwave radar radiometric calibration, the corner reflector acts as the standard reference target but its structure is usually deformed during the transportation and installation, or deformed by wind and gravity while permanently installed outdoor, which will decrease the RCS accuracy and therefore the radiometric calibration accuracy. A fast RCS accuracy measurement method based on 3-D measuring instrument and RCS simulation was proposed in this paper for tracking the characteristic variation of the corner reflector. In the first step, RCS simulation algorithm was selected and its simulation accuracy was assessed. In the second step, the 3-D measuring instrument was selected and its measuring accuracy was evaluated. Once the accuracy of the selected RCS simulation algorithm and 3-D measuring instrument was satisfied for the RCS accuracy assessment, the 3-D structure of the corner reflector would be obtained by the 3-D measuring instrument, and then the RCSs of the obtained 3-D structure and corresponding ideal structure would be calculated respectively based on the selected RCS simulation algorithm. The final RCS accuracy was the absolute difference of the two RCS calculation results. The advantage of the proposed method was that it could be applied outdoor easily, avoiding the correlation among the plate edge length error, plate orthogonality error, plate curvature error. The accuracy of this method is higher than the method using distortion equation. In the end of the paper, a measurement example was presented in order to show the performance of the proposed method.

  15. Discussion on accuracy degree evaluation of accident velocity reconstruction model

    NASA Astrophysics Data System (ADS)

    Zou, Tiefang; Dai, Yingbiao; Cai, Ming; Liu, Jike

    In order to investigate the applicability of accident velocity reconstruction model in different cases, a method used to evaluate accuracy degree of accident velocity reconstruction model is given. Based on pre-crash velocity in theory and calculation, an accuracy degree evaluation formula is obtained. With a numerical simulation case, Accuracy degrees and applicability of two accident velocity reconstruction models are analyzed; results show that this method is feasible in practice.

  16. Accuracy of tablet splitting and liquid measurements: an examination of who, what and how.

    PubMed

    Abu-Geras, Dana; Hadziomerovic, Dunja; Leau, Andrew; Khan, Ramzan Nazim; Gudka, Sajni; Locher, Cornelia; Razaghikashani, Maryam; Lim, Lee Yong

    2017-05-01

    To examine factors that might affect the ability of patients to accurately halve tablets or measure a 5-ml liquid dose. Eighty-eight participants split four different placebo tablets by hand and using a tablet splitter, while 85 participants measured 5 ml of water, 0.5% methylcellulose (MC) and 1% MC using a syringe and dosing cup. Accuracy of manipulation was determined by mass measurements. The general population was less able than pharmacy students to break tablets into equal parts, although age, gender and prior experience were insignificant factors. Greater accuracy of tablet halving was observed with tablet splitter, with scored tablets split more equally than unscored tablets. Tablet size did not affect the accuracy of splitting. However, >25% of small scored tablets failed to be split by hand, and 41% of large unscored tablets were split into >2 portions in the tablet splitter. In liquid measurement, the syringe provided more accurate volume measurements than the dosing cup, with higher accuracy observed for the more viscous MC solutions than water. Formulation characteristics and manipulation technique have greater influences on the accuracy of medication modification and should be considered in off-label drug use in vulnerable populations. © 2016 Royal Pharmaceutical Society.

  17. Modeling Individual Differences in Response Time and Accuracy in Numeracy

    PubMed Central

    Ratcliff, Roger; Thompson, Clarissa A.; McKoon, Gail

    2015-01-01

    In the study of numeracy, some hypotheses have been based on response time (RT) as a dependent variable and some on accuracy, and considerable controversy has arisen about the presence or absence of correlations between RT and accuracy, between RT or accuracy and individual differences like IQ and math ability, and between various numeracy tasks. In this article, we show that an integration of the two dependent variables is required, which we accomplish with a theory-based model of decision making. We report data from four tasks: numerosity discrimination, number discrimination, memory for two-digit numbers, and memory for three-digit numbers. Accuracy correlated across tasks, as did RTs. However, the negative correlations that might be expected between RT and accuracy were not obtained; if a subject was accurate, it did not mean that they were fast (and vice versa). When the diffusion decision-making model was applied to the data (Ratcliff, 1978), we found significant correlations across the tasks between the quality of the numeracy information (drift rate) driving the decision process and between the speed/ accuracy criterion settings, suggesting that similar numeracy skills and similar speed-accuracy settings are involved in the four tasks. In the model, accuracy is related to drift rate and RT is related to speed-accuracy criteria, but drift rate and criteria are not related to each other across subjects. This provides a theoretical basis for understanding why negative correlations were not obtained between accuracy and RT. We also manipulated criteria by instructing subjects to maximize either speed or accuracy, but still found correlations between the criteria settings between and within tasks, suggesting that the settings may represent an individual trait that can be modulated but not equated across subjects. Our results demonstrate that a decision-making model may provide a way to reconcile inconsistent and sometimes contradictory results in numeracy

  18. Heart imaging: the accuracy of the 64-MSCT in the detection of coronary artery disease.

    PubMed

    Alessandri, N; Di Matteo, A; Rondoni, G; Petrassi, M; Tufani, F; Ferrari, R; Laghi, A

    2009-01-01

    At present, coronary angiography represents the gold standard technique for the diagnosis of coronary artery disease. Our aim is to compare the conventional coronary angiography to the coronary 64-multislice spiral computed tomography (64-MSCT), a new and non-invasive cardiac imaging technique. The last generation of MSCT scanners show a better imaging quality, due to a greater spatial and temporal resolution. Four expert observers (two cardiologists and two radiologists) have compared the angiographic data with the accuracy of the 64-MSCT in the detection and evaluation of coronary vessels stenoses. From the data obtained, the sensibility, the specificity and the accuracy of the coronary 64-MSCT have been defined. We have enrolled 75 patients (57 male, 18 female, mean age 61.83 +/- 10.38; range 30-80 years) with known or suspected coronary artery disease. The above population has been divided into 3 groups: Group A (Gr. A) with 40 patients (mean age 60.7 +/- 12.5) affected by both non-significant and significant coronary artery disease; Group B (Gr. B) with 25 patients (mean age 60.3 +/- 14.6) who underwent to percutaneous coronary intervention (PCI); Group C (Gr. C) with 10 patients (mean age 54.20 +/- 13.7) without any coronary angiographic stenoses. All the patients underwent non-invasive exams, conventional coronary angiography and coronary 64-MSCT. The comparison of the data obtained has been carried out according to a per group analysis, per patient analysis and per segment analysis. Moreover, the accuracy of the 64-MSCT has been defined for the detection of >75%, 50-75% and <50% coronary stenoses. Coronary angiography has identified significant coronary artery disease in 75% of the patients in the Gr. A and in 73% of the patients in the Gr. B. No coronary stenoses have been detected in Gr. C. According to a per segment analysis, in Gr. A, 36% of the segments analysed have shown a coronary stenosis (37% stenoses >75%, 32% stenoses 50-75% and 31% stenoses <50

  19. Shear-Wave Elastography for the Estimation of Liver Fibrosis in Chronic Liver Disease: Determining Accuracy and Ideal Site for Measurement

    PubMed Central

    Dhyani, Manish; Vij, Abhinav; Bhan, Atul K.; Halpern, Elkan F.; Méndez-Navarro, Jorge; Corey, Kathleen E.; Chung, Raymond T.

    2015-01-01

    Purpose To evaluate the accuracy of shear-wave elastography (SWE) for staging liver fibrosis in patients with diffuse liver disease (including patients with hepatitis C virus [HCV]) and to determine the relative accuracy of SWE measurements obtained from different hepatic acquisition sites for staging liver fibrosis. Materials and Methods The institutional review board approved this single-institution prospective study, which was performed between January 2010 and March 2013 in 136 consecutive patients who underwent SWE before their scheduled liver biopsy (age range, 18–76 years; mean age, 49 years; 70 men, 66 women). Informed consent was obtained from all patients. SWE measurements were obtained at four sites in the liver. Biopsy specimens were reviewed in a blinded manner by a pathologist using METAVIR criteria. SWE measurements and biopsy results were compared by using the Spearman correlation and receiver operating characteristic (ROC) curve analysis. Results SWE values obtained at the upper right lobe showed the highest correlation with estimation of fibrosis (r = 0.41, P < .001). Inflammation and steatosis did not show any correlation with SWE values except for values from the left lobe, which showed correlation with steatosis (r = 0.24, P = .004). The area under the ROC curve (AUC) in the differentiation of stage F2 fibrosis or greater, stage F3 fibrosis or greater, and stage F4 fibrosis was 0.77 (95% confidence interval [CI]: 0.68, 0.86), 0.82 (95% CI: 0.75, 0.91), and 0.82 (95% CI: 0.70, 0.95), respectively, for all subjects who underwent liver biopsy. The corresponding AUCs for the subset of patients with HCV were 0.80 (95% CI: 0.67, 0.92), 0.82 (95% CI: 0.70, 0.95), and 0.89 (95% CI: 0.73, 1.00). The adjusted AUCs for differentiating stage F2 or greater fibrosis in patients with chronic liver disease and those with HCV were 0.84 and 0.87, respectively. Conclusion SWE estimates of liver stiffness obtained from the right upper lobe showed the best

  20. High accuracy wavelength calibration for a scanning visible spectrometer.

    PubMed

    Scotti, Filippo; Bell, Ronald E

    2010-10-01

    Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤0.2 Å. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of ∼0.25 Å has been demonstrated. With the addition of a high resolution (0.075 arc  sec) optical encoder on the grating stage, greater precision (∼0.005 Å) is possible, allowing absolute velocity measurements within ∼0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

  1. Cost and accuracy of advanced breeding trial designs in apple

    PubMed Central

    Harshman, Julia M; Evans, Kate M; Hardner, Craig M

    2016-01-01

    Trialing advanced candidates in tree fruit crops is expensive due to the long-term nature of the planting and labor-intensive evaluations required to make selection decisions. How closely the trait evaluations approximate the true trait value needs balancing with the cost of the program. Designs of field trials of advanced apple candidates in which reduced number of locations, the number of years and the number of harvests per year were modeled to investigate the effect on the cost and accuracy in an operational breeding program. The aim was to find designs that would allow evaluation of the most additional candidates while sacrificing the least accuracy. Critical percentage difference, response to selection, and correlated response were used to examine changes in accuracy of trait evaluations. For the quality traits evaluated, accuracy and response to selection were not substantially reduced for most trial designs. Risk management influences the decision to change trial design, and some designs had greater risk associated with them. Balancing cost and accuracy with risk yields valuable insight into advanced breeding trial design. The methods outlined in this analysis would be well suited to other horticultural crop breeding programs. PMID:27019717

  2. Accuracy of digital American Board of Orthodontics Discrepancy Index measurements.

    PubMed

    Dragstrem, Kristina; Galang-Boquiren, Maria Therese S; Obrez, Ales; Costa Viana, Maria Grace; Grubb, John E; Kusnoto, Budi

    2015-07-01

    A digital analysis that is shown to be accurate will ease the demonstration of initial case complexity. To date, no literature exists on the accuracy of the digital American Board of Orthodontics Discrepancy Index (DI) calculations when applied to pretreatment digital models. Plaster models were obtained from 45 previous patients with varying degrees of malocclusion. Total DI scores and the target disorders were computed manually with a periodontal probe on the original plaster casts (gold standard) and digitally using Ortho Insight 3D (Motion View Software, Hixson, Tenn) and OrthoCAD (Cadent, Carlstadt, NJ). Intrarater and interrater reliabilities were assessed for 15 subjects using the Spearman rho correlation test. Accuracies of the DI scores and target disorders were assessed for all 45 subjects using Wilcoxon signed ranks tests. Intrarater and interrater reliabilities were high for total DI scores and most target disorders (r > 0.8). No significant difference was found between total DI score when measured with OrthoCAD compared with manual calculations. The total DI scores calculated by Ortho Insight 3D were found to be significantly greater than those by manual calculation by 2.71 points. The findings indicate that a DI calculated by Ortho Insight 3D may lead the clinician to overestimate case complexity. OrthoCAD's DI module was demonstrated to be a clinically acceptable alternative to manual calculation of the total scores. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  3. Continuous Glucose Monitoring in Subjects with Type 1 Diabetes: Improvement in Accuracy by Correcting for Background Current

    PubMed Central

    Youssef, Joseph El; Engle, Julia M.; Massoud, Ryan G.; Ward, W. Kenneth

    2010-01-01

    Abstract Background A cause of suboptimal accuracy in amperometric glucose sensors is the presence of a background current (current produced in the absence of glucose) that is not accounted for. We hypothesized that a mathematical correction for the estimated background current of a commercially available sensor would lead to greater accuracy compared to a situation in which we assumed the background current to be zero. We also tested whether increasing the frequency of sensor calibration would improve sensor accuracy. Methods This report includes analysis of 20 sensor datasets from seven human subjects with type 1 diabetes. Data were divided into a training set for algorithm development and a validation set on which the algorithm was tested. A range of potential background currents was tested. Results Use of the background current correction of 4 nA led to a substantial improvement in accuracy (improvement of absolute relative difference or absolute difference of 3.5–5.5 units). An increase in calibration frequency led to a modest accuracy improvement, with an optimum at every 4 h. Conclusions Compared to no correction, a correction for the estimated background current of a commercially available glucose sensor led to greater accuracy and better detection of hypoglycemia and hyperglycemia. The accuracy-optimizing scheme presented here can be implemented in real time. PMID:20879968

  4. Severity of depressive symptoms and accuracy of dietary reporting among obese women with major depressive disorder seeking weight loss treatment.

    PubMed

    Whited, Matthew C; Schneider, Kristin L; Appelhans, Bradley M; Ma, Yunsheng; Waring, Molly E; DeBiasse, Michele A; Busch, Andrew M; Oleski, Jessica L; Merriam, Philip A; Olendzki, Barbara C; Crawford, Sybil L; Ockene, Ira S; Lemon, Stephenie C; Pagoto, Sherry L

    2014-01-01

    An elevation in symptoms of depression has previously been associated with greater accuracy of reported dietary intake, however this association has not been investigated among individuals with a diagnosis of major depressive disorder. The purpose of this study was to investigate reporting accuracy of dietary intake among a group of women with major depressive disorder in order to determine if reporting accuracy is similarly associated with depressive symptoms among depressed women. Reporting accuracy of dietary intake was calculated based on three 24-hour phone-delivered dietary recalls from the baseline phase of a randomized trial of weight loss treatment for 161 obese women with major depressive disorder. Regression models indicated that higher severity of depressive symptoms was associated with greater reporting accuracy, even when controlling for other factors traditionally associated with reporting accuracy (coefficient  =  0.01 95% CI = 0.01 - 0.02). Seventeen percent of the sample was classified as low energy reporters. Reporting accuracy of dietary intake increases along with depressive symptoms, even among individuals with major depressive disorder. These results suggest that any study investigating associations between diet quality and depression should also include an index of reporting accuracy of dietary intake as accuracy varies with the severity of depressive symptoms.

  5. Cost, accuracy, and consistency comparisons of land use maps made from high-altitutde aircraft photography and ERTS imagery

    USGS Publications Warehouse

    Fitzpatrick, Katherine A.

    1975-01-01

    Accuracy analyses for the land use maps of the Central Atlantic Regional Ecological Test Site were performed for a 1-percent sample of the area. Researchers compared Level II land use maps produced at three scales, 1:24,000, 1:100,000, and 1:250,000 from high-altitude photography, with each other and with point data obtained in the field. They employed the same procedures to determine the accuracy of the Level I land use maps produced at 1:250,000 from high-altitude photography and color composite ERTS imagery. The accuracy of the Level II maps was 84.9 percent at 1:24,000, 77.4 percent at 1:100,000, and 73.0 percent at 1:250,000. The accuracy of the Level I 1:250,000 maps produced from high-altitude aircraft photography was 76.5 percent and for those produced from ERTS imagery was 69.5 percent The cost of Level II land use mapping at 1:24,000 was found to be high ($11.93 per km2 ). The cost of mapping at 1:100,000 ($1.75) was about 2 times as expensive as mapping at 1:250,000 ($.88), and the accuracy increased by only 4.4 percent. Level I land use maps, when mapped from highaltitude photography, were about 4 times as expensive as the maps produced from ERTS imagery, although the accuracy is 7.0 percent greater. The Level I land use category that is least accurately mapped from ERTS imagery is urban and built-up land in the non-urban areas; in the urbanized areas, built-up land is more reliably mapped.

  6. Evaluating Rater Accuracy in Rater-Mediated Assessments Using an Unfolding Model

    ERIC Educational Resources Information Center

    Wang, Jue; Engelhard, George, Jr.; Wolfe, Edward W.

    2016-01-01

    The number of performance assessments continues to increase around the world, and it is important to explore new methods for evaluating the quality of ratings obtained from raters. This study describes an unfolding model for examining rater accuracy. Accuracy is defined as the difference between observed and expert ratings. Dichotomous accuracy…

  7. a New Approach for Accuracy Improvement of Pulsed LIDAR Remote Sensing Data

    NASA Astrophysics Data System (ADS)

    Zhou, G.; Huang, W.; Zhou, X.; He, C.; Li, X.; Huang, Y.; Zhang, L.

    2018-05-01

    In remote sensing applications, the accuracy of time interval measurement is one of the most important parameters that affect the quality of pulsed lidar data. The traditional time interval measurement technique has the disadvantages of low measurement accuracy, complicated circuit structure and large error. A high-precision time interval data cannot be obtained in these traditional methods. In order to obtain higher quality of remote sensing cloud images based on the time interval measurement, a higher accuracy time interval measurement method is proposed. The method is based on charging the capacitance and sampling the change of capacitor voltage at the same time. Firstly, the approximate model of the capacitance voltage curve in the time of flight of pulse is fitted based on the sampled data. Then, the whole charging time is obtained with the fitting function. In this method, only a high-speed A/D sampler and capacitor are required in a single receiving channel, and the collected data is processed directly in the main control unit. The experimental results show that the proposed method can get error less than 3 ps. Compared with other methods, the proposed method improves the time interval accuracy by at least 20 %.

  8. A new method to obtain ground control points based on SRTM data

    NASA Astrophysics Data System (ADS)

    Wang, Pu; An, Wei; Deng, Xin-pu; Zhang, Xi

    2013-09-01

    The GCPs are widely used in remote sense image registration and geometric correction. Normally, the DRG and DOM are the major data source from which GCPs are extracted. But the high accuracy products of DRG and DOM are usually costly to obtain. Some of the production are free, yet without any guarantee. In order to balance the cost and the accuracy, the paper proposes a method of extracting the GCPs from SRTM data. The method consist of artificial assistance, binarization, data resample and reshape. With artificial assistance to find out which part of SRTM data could be used as GCPs, such as the islands or sharp coast line. By utilizing binarization algorithm , the shape information of the region is obtained while other information is excluded. Then the binary data is resampled to a suitable resolution required by specific application. At last, the data would be reshaped according to satellite imaging type to obtain the GCPs which could be used. There are three advantages of the method proposed in the paper. Firstly, the method is easy for implementation. Unlike the DRG data or DOM data that charges a lot, the SRTM data is totally free to access without any constricts. Secondly, the SRTM has a high accuracy about 90m that is promised by its producer, so the GCPs got from it can also obtain a high quality. Finally, given the SRTM data covers nearly all the land surface of earth between latitude -60° and latitude +60°, the GCPs which are produced by the method can cover most important regions of the world. The method which obtain GCPs from SRTM data can be used in meteorological satellite image or some situation alike, which have a relative low requirement about the accuracy. Through plenty of simulation test, the method is proved convenient and effective.

  9. Multiply charged particles of the primary cosmic rays with energies greater than about 2 TeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanenko, I.P.; Grigorov, N.L.; Shestoperov, V.IA.

    1986-08-01

    Data on the energy spectra and charge composition of primary cosmic ray particles with energies greater than about 2 TeV are analyzed. The equipment on the Kosmos 1543 satellite used to obtain the data is described. Protons and alpha particles are detected, and the nuclei are separated into H, M, VH, and alpha groups. It is determined that the charge compositions of the primary nuclei with z greater than about 2 at energies greater than about 2 TeV compare well with data obtained at energies greater than about 1-10 GeV/nucleon. 8 references.

  10. Dimensional accuracy and surface property of titanium casting using gypsum-bonded alumina investment.

    PubMed

    Yan, Min; Takahashi, Hidekazu; Nishimura, Fumio

    2004-12-01

    The aim of the present study was to evaluate the dimensional accuracy and surface property of titanium casting obtained using a gypsum-bonded alumina investment. The experimental gypsum-bonded alumina investment with 20 mass% gypsum content mixed with 2 mass% potassium sulfate was used for five cp titanium castings and three Cu-Zn alloy castings. The accuracy, surface roughness (Ra), and reaction layer thickness of these castings were investigated. The accuracy of the castings obtained from the experimental investment ranged from -0.04 to 0.23%, while surface roughness (Ra) ranged from 7.6 to 10.3microm. A reaction layer of about 150 microm thickness under the titanium casting surface was observed. These results suggested that the titanium casting obtained using the experimental investment was acceptable. Although the reaction layer was thin, surface roughness should be improved.

  11. Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.

    PubMed

    Zhao, Qin

    2012-01-01

    The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.

  12. Modifications to the accuracy assessment analysis routine MLTCRP to produce an output file

    NASA Technical Reports Server (NTRS)

    Carnes, J. G.

    1978-01-01

    Modifications are described that were made to the analysis program MLTCRP in the accuracy assessment software system to produce a disk output file. The output files produced by this modified program are used to aggregate data for regions greater than a single segment.

  13. Estimated Accuracy of Three Common Trajectory Statistical Methods

    NASA Technical Reports Server (NTRS)

    Kabashnikov, Vitaliy P.; Chaikovsky, Anatoli P.; Kucsera, Tom L.; Metelskaya, Natalia S.

    2011-01-01

    Three well-known trajectory statistical methods (TSMs), namely concentration field (CF), concentration weighted trajectory (CWT), and potential source contribution function (PSCF) methods were tested using known sources and artificially generated data sets to determine the ability of TSMs to reproduce spatial distribution of the sources. In the works by other authors, the accuracy of the trajectory statistical methods was estimated for particular species and at specified receptor locations. We have obtained a more general statistical estimation of the accuracy of source reconstruction and have found optimum conditions to reconstruct source distributions of atmospheric trace substances. Only virtual pollutants of the primary type were considered. In real world experiments, TSMs are intended for application to a priori unknown sources. Therefore, the accuracy of TSMs has to be tested with all possible spatial distributions of sources. An ensemble of geographical distributions of virtual sources was generated. Spearman s rank order correlation coefficient between spatial distributions of the known virtual and the reconstructed sources was taken to be a quantitative measure of the accuracy. Statistical estimates of the mean correlation coefficient and a range of the most probable values of correlation coefficients were obtained. All the TSMs that were considered here showed similar close results. The maximum of the ratio of the mean correlation to the width of the correlation interval containing the most probable correlation values determines the optimum conditions for reconstruction. An optimal geographical domain roughly coincides with the area supplying most of the substance to the receptor. The optimal domain s size is dependent on the substance decay time. Under optimum reconstruction conditions, the mean correlation coefficients can reach 0.70 0.75. The boundaries of the interval with the most probable correlation values are 0.6 0.9 for the decay time of 240 h

  14. Precise attitude rate estimation using star images obtained by mission telescope for satellite missions

    NASA Astrophysics Data System (ADS)

    Inamori, Takaya; Hosonuma, Takayuki; Ikari, Satoshi; Saisutjarit, Phongsatorn; Sako, Nobutada; Nakasuka, Shinichi

    2015-02-01

    Recently, small satellites have been employed in various satellite missions such as astronomical observation and remote sensing. During these missions, the attitudes of small satellites should be stabilized to a higher accuracy to obtain accurate science data and images. To achieve precise attitude stabilization, these small satellites should estimate their attitude rate under the strict constraints of mass, space, and cost. This research presents a new method for small satellites to precisely estimate angular rate using star blurred images by employing a mission telescope to achieve precise attitude stabilization. In this method, the angular velocity is estimated by assessing the quality of a star image, based on how blurred it appears to be. Because the proposed method utilizes existing mission devices, a satellite does not require additional precise rate sensors, which makes it easier to achieve precise stabilization given the strict constraints possessed by small satellites. The research studied the relationship between estimation accuracy and parameters used to achieve an attitude rate estimation, which has a precision greater than 1 × 10-6 rad/s. The method can be applied to all attitude sensors, which use optics systems such as sun sensors and star trackers (STTs). Finally, the method is applied to the nano astrometry satellite Nano-JASMINE, and we investigate the problems that are expected to arise with real small satellites by performing numerical simulations.

  15. Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions

    PubMed Central

    Pascual-Moscardó, Agustín; Camps, Isabel

    2018-01-01

    Background The scanner does not measure the dental surface continually. Instead, it generates a point cloud, and these points are then joined to form the scanned object. This approximation will depend on the number of points generated (resolution), which can lead to low accuracy (trueness and precision) when fewer points are obtained. The purpose of this study is to determine the resolution of four intraoral digital imaging systems and to demonstrate the relationship between accuracy and resolution of the intraoral scanner in impressions of a complete dental arch. Material and Methods A master cast of the complete maxillary arch was prepared with different dental preparations. Using four digital impression systems, the cast was scanned inside of a black methacrylate box, obtaining a total of 40 digital impressions from each scanner. The resolution was obtained by dividing the number of points of each digital impression by the total surface area of the cast. Accuracy was evaluated using a three-dimensional measurement software, using the “best alignment” method of the casts with a highly faithful reference model obtained from an industrial scanner. Pearson correlation was used for statistical analysis of the data. Results Of the intraoral scanners, Omnicam is the system with the best resolution, with 79.82 points per mm2, followed by True Definition with 54.68 points per mm2, Trios with 41.21 points per mm2, and iTero with 34.20 points per mm2. However, the study found no relationship between resolution and accuracy of the study digital impression systems (P >0.05), except for Omnicam and its precision. Conclusions The resolution of the digital impression systems has no relationship with the accuracy they achieve in the impression of a complete dental arch. The study found that the Omnicam scanner is the system that obtains the best resolution, and that as the resolution increases, its precision increases. Key words:Trueness, precision, accuracy, resolution

  16. Emotion perception accuracy and bias in face-to-face versus cyberbullying.

    PubMed

    Ciucci, Enrica; Baroncelli, Andrea; Nowicki, Stephen

    2014-01-01

    The authors investigated the association of traditional and cyber forms of bullying and victimization with emotion perception accuracy and emotion perception bias. Four basic emotions were considered (i.e., happiness, sadness, anger, and fear); 526 middle school students (280 females; M age = 12.58 years, SD = 1.16 years) were recruited, and emotionality was controlled. Results indicated no significant findings for girls. Boys with higher levels of traditional bullying did not show any deficit in perception accuracy of emotions, but they were prone to identify happiness and fear in faces when a different emotion was expressed; in addition, male cyberbullying was related to greater accuracy in recognizing fear. In terms of the victims, cyber victims had a global problem in recognizing emotions and a specific problem in processing anger and fear. It was concluded that emotion perception accuracy and bias were associated with bullying and victimization for boys not only in traditional settings but also in the electronic ones. Implications of these findings for possible intervention are discussed.

  17. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time

    PubMed Central

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2015-01-01

    Background Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. Methods This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. Findings Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. Interpretation The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. Conclusions Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their

  18. Estimating orientation using magnetic and inertial sensors and different sensor fusion approaches: accuracy assessment in manual and locomotion tasks.

    PubMed

    Bergamini, Elena; Ligorio, Gabriele; Summa, Aurora; Vannozzi, Giuseppe; Cappozzo, Aurelio; Sabatini, Angelo Maria

    2014-10-09

    Magnetic and inertial measurement units are an emerging technology to obtain 3D orientation of body segments in human movement analysis. In this respect, sensor fusion is used to limit the drift errors resulting from the gyroscope data integration by exploiting accelerometer and magnetic aiding sensors. The present study aims at investigating the effectiveness of sensor fusion methods under different experimental conditions. Manual and locomotion tasks, differing in time duration, measurement volume, presence/absence of static phases, and out-of-plane movements, were performed by six subjects, and recorded by one unit located on the forearm or the lower trunk, respectively. Two sensor fusion methods, representative of the stochastic (Extended Kalman Filter) and complementary (Non-linear observer) filtering, were selected, and their accuracy was assessed in terms of attitude (pitch and roll angles) and heading (yaw angle) errors using stereophotogrammetric data as a reference. The sensor fusion approaches provided significantly more accurate results than gyroscope data integration. Accuracy improved mostly for heading and when the movement exhibited stationary phases, evenly distributed 3D rotations, it occurred in a small volume, and its duration was greater than approximately 20 s. These results were independent from the specific sensor fusion method used. Practice guidelines for improving the outcome accuracy are provided.

  19. Assessment of the Thematic Accuracy of Land Cover Maps

    NASA Astrophysics Data System (ADS)

    Höhle, J.

    2015-08-01

    Several land cover maps are generated from aerial imagery and assessed by different approaches. The test site is an urban area in Europe for which six classes (`building', `hedge and bush', `grass', `road and parking lot', `tree', `wall and car port') had to be derived. Two classification methods were applied (`Decision Tree' and `Support Vector Machine') using only two attributes (height above ground and normalized difference vegetation index) which both are derived from the images. The assessment of the thematic accuracy applied a stratified design and was based on accuracy measures such as user's and producer's accuracy, and kappa coefficient. In addition, confidence intervals were computed for several accuracy measures. The achieved accuracies and confidence intervals are thoroughly analysed and recommendations are derived from the gained experiences. Reliable reference values are obtained using stereovision, false-colour image pairs, and positioning to the checkpoints with 3D coordinates. The influence of the training areas on the results is studied. Cross validation has been tested with a few reference points in order to derive approximate accuracy measures. The two classification methods perform equally for five classes. Trees are classified with a much better accuracy and a smaller confidence interval by means of the decision tree method. Buildings are classified by both methods with an accuracy of 99% (95% CI: 95%-100%) using independent 3D checkpoints. The average width of the confidence interval of six classes was 14% of the user's accuracy.

  20. Evaluation of the accuracy of GPS as a method of locating traffic collisions.

    DOT National Transportation Integrated Search

    2004-06-01

    The objective of this study were to determine the accuracy of GPS units as a traffic crash location tool, evaluate the accuracy of the location data obtained using the GPS units, and determine the largest sources of any errors found. : The analysis s...

  1. Genomic selection accuracies within and between environments and small breeding groups in white spruce.

    PubMed

    Beaulieu, Jean; Doerksen, Trevor K; MacKay, John; Rainville, André; Bousquet, Jean

    2014-12-02

    Genomic selection (GS) may improve selection response over conventional pedigree-based selection if markers capture more detailed information than pedigrees in recently domesticated tree species and/or make it more cost effective. Genomic prediction accuracies using 1748 trees and 6932 SNPs representative of as many distinct gene loci were determined for growth and wood traits in white spruce, within and between environments and breeding groups (BG), each with an effective size of Ne ≈ 20. Marker subsets were also tested. Model fits and/or cross-validation (CV) prediction accuracies for ridge regression (RR) and the least absolute shrinkage and selection operator models approached those of pedigree-based models. With strong relatedness between CV sets, prediction accuracies for RR within environment and BG were high for wood (r = 0.71-0.79) and moderately high for growth (r = 0.52-0.69) traits, in line with trends in heritabilities. For both classes of traits, these accuracies achieved between 83% and 92% of those obtained with phenotypes and pedigree information. Prediction into untested environments remained moderately high for wood (r ≥ 0.61) but dropped significantly for growth (r ≥ 0.24) traits, emphasizing the need to phenotype in all test environments and model genotype-by-environment interactions for growth traits. Removing relatedness between CV sets sharply decreased prediction accuracies for all traits and subpopulations, falling near zero between BGs with no known shared ancestry. For marker subsets, similar patterns were observed but with lower prediction accuracies. Given the need for high relatedness between CV sets to obtain good prediction accuracies, we recommend to build GS models for prediction within the same breeding population only. Breeding groups could be merged to build genomic prediction models as long as the total effective population size does not exceed 50 individuals in order to obtain high prediction accuracy such as that

  2. Improving the accuracy of acetabular cup implantation using a bulls-eye spirit level.

    PubMed

    Macdonald, Duncan; Gupta, Sanjay; Ohly, Nicholas E; Patil, Sanjeev; Meek, R; Mohammed, Aslam

    2011-01-01

    Acetabular introducers have a built-in inclination of 45 degrees to the handle shaft. With patients in the lateral position, surgeons aim to align the introducer shaft vertical to the floor to implant the acetabulum at 45 degrees. We aimed to determine if a bulls-eye spirit level attached to an introducer improved the accuracy of implantation. A small circular bulls-eye spirit level was attached to the handle of an acetabular introducer. A saw bone hemipelvis was fixed to a horizontal, flat surface. A cement substitute was placed in the acetabulum and subjects were asked to implant a polyethylene cup, aiming to obtain an angle of inclination of 45 degrees. Two attempts were made with the spirit level masked and two with it unmasked. The distance of the air bubble from the spirit level's center was recorded by a single assessor. The angle of inclination of the acetabular component was then calculated. Subjects included both orthopedic consultants and trainees. Twenty-five subjects completed the study. Accuracy of acetabular implantation when using the unmasked spirit level improved significantly in all grades of surgeon. With the spirit level masked, 12 out of 50 attempts were accurate at 45 degrees inclination; 11 out of 50 attempts were "open," with greater than 45 degrees of inclination, and 27 were "closed," with less than 45 degrees. With the spirit level visible, all subjects achieved an inclination angle of exactly 45 degrees. A simple device attached to the handle of an acetabular introducer can significantly improve the accuracy of implantation of a cemented cup into a saw bone pelvis in the lateral position.

  3. Accuracy and Precision of Silicon Based Impression Media for Quantitative Areal Texture Analysis

    PubMed Central

    Goodall, Robert H.; Darras, Laurent P.; Purnell, Mark A.

    2015-01-01

    Areal surface texture analysis is becoming widespread across a diverse range of applications, from engineering to ecology. In many studies silicon based impression media are used to replicate surfaces, and the fidelity of replication defines the quality of data collected. However, while different investigators have used different impression media, the fidelity of surface replication has not been subjected to quantitative analysis based on areal texture data. Here we present the results of an analysis of the accuracy and precision with which different silicon based impression media of varying composition and viscosity replicate rough and smooth surfaces. Both accuracy and precision vary greatly between different media. High viscosity media tested show very low accuracy and precision, and most other compounds showed either the same pattern, or low accuracy and high precision, or low precision and high accuracy. Of the media tested, mid viscosity President Jet Regular Body and low viscosity President Jet Light Body (Coltène Whaledent) are the only compounds to show high levels of accuracy and precision on both surface types. Our results show that data acquired from different impression media are not comparable, supporting calls for greater standardisation of methods in areal texture analysis. PMID:25991505

  4. Auditory and visual localization accuracy in young children and adults.

    PubMed

    Martin, Karen; Johnstone, Patti; Hedrick, Mark

    2015-06-01

    This study aimed to measure and compare sound and light source localization ability in young children and adults who have normal hearing and normal/corrected vision in order to determine the extent to which age, type of stimuli, and stimulus order affects sound localization accuracy. Two experiments were conducted. The first involved a group of adults only. The second involved a group of 30 children aged 3 to 5 years. Testing occurred in a sound-treated booth containing a semi-circular array of 15 loudspeakers set at 10° intervals from -70° to 70° azimuth. Each loudspeaker had a tiny light bulb and a small picture fastened underneath. Seven of the loudspeakers were used to randomly test sound and light source identification. The sound stimulus was the word "baseball". The light stimulus was a flashing of a light bulb triggered by the digital signal of the word "baseball". Each participant was asked to face 0° azimuth, and identify the location of the test stimulus upon presentation. Adults used a computer mouse to click on an icon; children responded by verbally naming or walking toward the picture underneath the corresponding loudspeaker or light. A mixed experimental design using repeated measures was used to determine the effect of age and stimulus type on localization accuracy in children and adults. A mixed experimental design was used to compare the effect of stimulus order (light first/last) and varying or fixed intensity sound on localization accuracy in children and adults. Localization accuracy was significantly better for light stimuli than sound stimuli for children and adults. Children, compared to adults, showed significantly greater localization errors for audition. Three-year-old children had significantly greater sound localization errors compared to 4- and 5-year olds. Adults performed better on the sound localization task when the light localization task occurred first. Young children can understand and attend to localization tasks, but show

  5. Examining the accuracy of foodservice in a hospital setting.

    PubMed

    Glover, N S; Keane, T M

    1984-09-01

    Although a great deal of research has been conducted to determine the appropriate diets for the prevention and treatment of various illnesses, there is very little in the literature about research that directly assesses the accuracy of the prescribed diets served to patients in a hospital setting. The present study was designed to evaluate the accuracy of meals served to patients by identifying critical errors and more general errors on trays about to be served. The results indicated that the error rate was greater on weekends and holidays than during the week. Significantly, a correlational analysis revealed that error rate was inversely related to the total number of foodservice supervisors and more specifically to the number of food production supervisors and registered dietitians present. The implications of the results for possible interventions and training are discussed.

  6. English Verb Accuracy of Bilingual Cantonese-English Preschoolers.

    PubMed

    Rezzonico, Stefano; Goldberg, Ahuva; Milburn, Trelani; Belletti, Adriana; Girolametto, Luigi

    2017-07-26

    Knowledge of verb development in typically developing bilingual preschoolers may inform clinicians about verb accuracy rates during the 1st 2 years of English instruction. This study aimed to investigate tensed verb accuracy in 2 assessment contexts in 4- and 5-year-old Cantonese-English bilingual preschoolers. The sample included 47 Cantonese-English bilinguals enrolled in English preschools. Half of the children were in their 1st 4 months of English language exposure, and half had completed 1 year and 4 months of exposure to English. Data were obtained from the Test of Early Grammatical Impairment (Rice & Wexler, 2001) and from a narrative generated in English. By the 2nd year of formal exposure to English, children in the present study approximated 33% accuracy of tensed verbs in a formal testing context versus 61% in a narrative context. The use of the English verb BE approximated mastery. Predictors of English third-person singular verb accuracy were task, grade, English expressive vocabulary, and lemma frequency. Verb tense accuracy was low across both groups, but a precocious mastery of BE was observed. The results of the present study suggest that speech-language pathologists may consider, in addition to an elicitation task, evaluating the use of verbs during narratives in bilingual Cantonese-English bilingual children.

  7. Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goodsitt, Mitchell M.; Christodoulou, Emmanuel G.; Larson, Sandra C.

    2011-04-15

    Purpose: This study was performed to investigate the accuracies of the synthesized monochromatic images and effective atomic number maps obtained with the new GE Discovery CT750 HD CT scanner. Methods: A Gammex-RMI model 467 tissue characterization phantom and the CT number linearity section of a Phantom Laboratory Catphan 600 phantom were scanned using the dual energy (DE) feature on the GE CT750 HD scanner. Synthesized monochromatic images at various energies between 40 and 120 keV and effective atomic number (Z{sub eff}) maps were generated. Regions of interest were placed within these images/maps to measure the average monochromatic CT numbers andmore » average Z{sub eff} of the materials within these phantoms. The true Z{sub eff} values were either supplied by the phantom manufacturer or computed using Mayneord's equation. The linear attenuation coefficients for the true CT numbers were computed using the NIST XCOM program with the input of manufacturer supplied elemental compositions and densities. The effects of small variations in the assumed true densities of the materials were also investigated. Finally, the effect of body size on the accuracies of the synthesized monochromatic CT numbers was investigated using a custom lumbar section phantom with and without an external fat-mimicking ring. Results: Other than the Z{sub eff} of the simulated lung inserts in the tissue characterization phantom, which could not be measured by DECT, the Z{sub eff} values of all of the other materials in the tissue characterization and Catphan phantoms were accurate to 15%. The accuracies of the synthesized monochromatic CT numbers of the materials in both phantoms varied with energy and material. For the 40-120 keV range, RMS errors between the measured and true CT numbers in the Catphan are 8-25 HU when the true CT numbers were computed using the nominal plastic densities. These RMS errors improve to 3-12 HU for assumed true densities within the nominal density {+-}0.02 g

  8. Orbit Determination Accuracy for Comets on Earth-Impacting Trajectories

    NASA Technical Reports Server (NTRS)

    Kay-Bunnell, Linda

    2004-01-01

    The results presented show the level of orbit determination accuracy obtainable for long-period comets discovered approximately one year before collision with Earth. Preliminary orbits are determined from simulated observations using Gauss' method. Additional measurements are incorporated to improve the solution through the use of a Kalman filter, and include non-gravitational perturbations due to outgassing. Comparisons between observatories in several different circular heliocentric orbits show that observatories in orbits with radii less than 1 AU result in increased orbit determination accuracy for short tracking durations due to increased parallax per unit time. However, an observatory at 1 AU will perform similarly if the tracking duration is increased, and accuracy is significantly improved if additional observatories are positioned at the Sun-Earth Lagrange points L3, L4, or L5. A single observatory at 1 AU capable of both optical and range measurements yields the highest orbit determination accuracy in the shortest amount of time when compared to other systems of observatories.

  9. A high-accuracy optical linear algebra processor for finite element applications

    NASA Technical Reports Server (NTRS)

    Casasent, D.; Taylor, B. K.

    1984-01-01

    Optical linear processors are computationally efficient computers for solving matrix-matrix and matrix-vector oriented problems. Optical system errors limit their dynamic range to 30-40 dB, which limits their accuray to 9-12 bits. Large problems, such as the finite element problem in structural mechanics (with tens or hundreds of thousands of variables) which can exploit the speed of optical processors, require the 32 bit accuracy obtainable from digital machines. To obtain this required 32 bit accuracy with an optical processor, the data can be digitally encoded, thereby reducing the dynamic range requirements of the optical system (i.e., decreasing the effect of optical errors on the data) while providing increased accuracy. This report describes a new digitally encoded optical linear algebra processor architecture for solving finite element and banded matrix-vector problems. A linear static plate bending case study is described which quantities the processor requirements. Multiplication by digital convolution is explained, and the digitally encoded optical processor architecture is advanced.

  10. Validation of geometric accuracy of Global Land Survey (GLS) 2000 data

    USGS Publications Warehouse

    Rengarajan, Rajagopalan; Sampath, Aparajithan; Storey, James C.; Choate, Michael J.

    2015-01-01

    The Global Land Survey (GLS) 2000 data were generated from Geocover™ 2000 data with the aim of producing a global data set of accuracy better than 25 m Root Mean Square Error (RMSE). An assessment and validation of accuracy of GLS 2000 data set, and its co-registration with Geocover™ 2000 data set is presented here. Since the availability of global data sets that have higher nominal accuracy than the GLS 2000 is a concern, the data sets were assessed in three tiers. In the first tier, the data were compared with the Geocover™ 2000 data. This comparison provided a means of localizing regions of higher differences. In the second tier, the GLS 2000 data were compared with systematically corrected Landsat-7 scenes that were obtained in a time period when the spacecraft pointing information was extremely accurate. These comparisons localize regions where the data are consistently off, which may indicate regions of higher errors. The third tier consisted of comparing the GLS 2000 data against higher accuracy reference data. The reference data were the Digital Ortho Quads over the United States, orthorectified SPOT data over Australia, and high accuracy check points obtained using triangulation bundle adjustment of Landsat-7 images over selected sites around the world. The study reveals that the geometric errors in Geocover™ 2000 data have been rectified in GLS 2000 data, and that the accuracy of GLS 2000 data can be expected to be better than 25 m RMSE for most of its constituent scenes.

  11. Accuracy and Reliability of Emergency Department Triage Using the Emergency Severity Index: An International Multicenter Assessment.

    PubMed

    Mistry, Binoy; Stewart De Ramirez, Sarah; Kelen, Gabor; Schmitz, Paulo S K; Balhara, Kamna S; Levin, Scott; Martinez, Diego; Psoter, Kevin; Anton, Xavier; Hinson, Jeremiah S

    2018-05-01

    We assess accuracy and variability of triage score assignment by emergency department (ED) nurses using the Emergency Severity Index (ESI) in 3 countries. In accordance with previous reports and clinical observation, we hypothesize low accuracy and high variability across all sites. This cross-sectional multicenter study enrolled 87 ESI-trained nurses from EDs in Brazil, the United Arab Emirates, and the United States. Standardized triage scenarios published by the Agency for Healthcare Research and Quality (AHRQ) were used. Accuracy was defined by concordance with the AHRQ key and calculated as percentages. Accuracy comparisons were made with one-way ANOVA and paired t test. Interrater reliability was measured with Krippendorff's α. Subanalyses based on nursing experience and triage scenario type were also performed. Mean accuracy pooled across all sites and scenarios was 59.2% (95% confidence interval [CI] 56.4% to 62.0%) and interrater reliability was modest (α=.730; 95% CI .692 to .767). There was no difference in overall accuracy between sites or according to nurse experience. Medium-acuity scenarios were scored with greater accuracy (76.4%; 95% CI 72.6% to 80.3%) than high- or low-acuity cases (44.1%, 95% CI 39.3% to 49.0% and 54%, 95% CI 49.9% to 58.2%), and adult scenarios were scored with greater accuracy than pediatric ones (66.2%, 95% CI 62.9% to 69.7% versus 46.9%, 95% CI 43.4% to 50.3%). In this multinational study, concordance of nurse-assigned ESI score with reference standard was universally poor and variability was high. Although the ESI is the most popular ED triage tool in the United States and is increasingly used worldwide, our findings point to a need for more reliable ED triage tools. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  12. Factors Influencing Science Content Accuracy in Elementary Inquiry Science Lessons

    NASA Astrophysics Data System (ADS)

    Nowicki, Barbara L.; Sullivan-Watts, Barbara; Shim, Minsuk K.; Young, Betty; Pockalny, Robert

    2013-06-01

    Elementary teachers face increasing demands to engage children in authentic science process and argument while simultaneously preparing them with knowledge of science facts, vocabulary, and concepts. This reform is particularly challenging due to concerns that elementary teachers lack adequate science background to teach science accurately. This study examined 81 in-classroom inquiry science lessons for preservice education majors and their cooperating teachers to determine the accuracy of the science content delivered in elementary classrooms. Our results showed that 74 % of experienced teachers and 50 % of student teachers presented science lessons with greater than 90 % accuracy. Eleven of the 81 lessons (9 preservice, 2 cooperating teachers) failed to deliver accurate science content to the class. Science content accuracy was highly correlated with the use of kit-based resources supported with professional development, a preference for teaching science, and grade level. There was no correlation between the accuracy of science content and some common measures of teacher content knowledge (i.e., number of college science courses, science grades, or scores on a general science content test). Our study concluded that when provided with high quality curricular materials and targeted professional development, elementary teachers learn needed science content and present it accurately to their students.

  13. Illusory expectations can affect retrieval-monitoring accuracy.

    PubMed

    McDonough, Ian M; Gallo, David A

    2012-03-01

    The present study investigated how expectations, even when illusory, can affect the accuracy of memory decisions. Participants studied words presented in large or small font for subsequent memory tests. Replicating prior work, judgments of learning indicated that participants expected to remember large words better than small words, even though memory for these words was equivalent on a standard test of recognition memory and subjective judgments. Critically, we also included tests that instructed participants to selectively search memory for either large or small words, thereby allowing different memorial expectations to contribute to performance. On these tests we found reduced false recognition when searching memory for large words relative to small words, such that the size illusion paradoxically affected accuracy measures (d' scores) in the absence of actual memory differences. Additional evidence for the role of illusory expectations was that (a) the accuracy effect was obtained only when participants searched memory for the aspect of the stimuli corresponding to illusory expectations (size instead of color) and (b) the accuracy effect was eliminated on a forced-choice test that prevented the influence of memorial expectations. These findings demonstrate the critical role of memorial expectations in the retrieval-monitoring process. 2012 APA, all rights reserved

  14. Role of interoceptive accuracy in topographical changes in emotion-induced bodily sensations

    PubMed Central

    Jung, Won-Mo; Ryu, Yeonhee; Lee, Ye-Seul; Wallraven, Christian; Chae, Younbyoung

    2017-01-01

    The emotion-associated bodily sensation map is composed of a specific topographical distribution of bodily sensations to categorical emotions. The present study investigated whether or not interoceptive accuracy was associated with topographical changes in this map following emotion-induced bodily sensations. This study included 31 participants who observed short video clips containing emotional stimuli and then reported their sensations on the body map. Interoceptive accuracy was evaluated with a heartbeat detection task and the spatial patterns of bodily sensations to specific emotions, including anger, fear, disgust, happiness, sadness, and neutral, were visualized using Statistical Parametric Mapping (SPM) analyses. Distinct patterns of bodily sensations were identified for different emotional states. In addition, positive correlations were found between the magnitude of sensation in emotion-specific regions and interoceptive accuracy across individuals. A greater degree of interoceptive accuracy was associated with more specific topographical changes after emotional stimuli. These results suggest that the awareness of one’s internal bodily states might play a crucial role as a required messenger of sensory information during the affective process. PMID:28877218

  15. 2D.02: ACCURACY OF ISOVOLUMETRIC CONTRACTION TIME OBTAINED BY CAROTID ARTERIAL TONOMETRY IN PATIENTS WITH CHRONIC LEFT VENTRICULAR FAILURE.

    PubMed

    Salvi, L; Grillo, A; Marelli, S; Gao, L; Giuliano, A; Trifirò, G; Santini, F; Pini, A; Salvi, P; Viecca, F; Carretta, R; Parati, G

    2015-06-01

    The Buckberg index (SEVR: subendocardial viability ratio) is considered a useful parameter for a non-invasive assessment of the relationship between subendocardial oxygen supply and demand. However, his classic calculation does not include the pre-ejection isovolumic contraction time in stroke work evaluation. The aim of our study was to evaluate the accuracy of the isovolumic contraction time obtained through the carotid pulse wave analysis, to be included in SEVR assessment. In 35 patients (mean age ± SD = 66 ± 13 yrs) followed-up for chronic left ventricular systolic failure (EF = 32 ± 8%) with no significant valvular disease, the pressure curve in the common carotid artery by tonometer (PulsePen) and the aortic transvalvular flow by EchocardioDoppler (Philips-EnVisor C-HD) were acquired simultaneously. The synchronization of data acquisition was verified by comparison of the RR intervals in the ECG signals recorded simultaneously to the two methods. The isovolumic contraction time was separately calculated by considering both the delay between the beginning of the aortic flow wave obtained by EchocardioDoppler and the R wave of the corresponding ECG, and the delay between the foot of the pressure wave recorded in the carotid artery by tonometry compared with the R wave of the corresponding ECG. The latter was corrected by considering the delay between ascending aorta and carotid pulses, computed as a function of the carotid-femoral pulse wave speed and of the distance between the point of carotid pulse acquisition and the sternal notch. The isovolumic contraction time computed by tonometry (68.8 ± 20.2 ms) was closely related to that measured with the EchocardioDoppler approach (68.8 ± 20.5 ms): y = 0.93x + 4.94; r = 0.93; p < 0.0001, with homogeneous distribution in Bland-Altman analysis (mean difference -0.1 ± 7.57 ms). The ratios between isovolumic contraction time and systolic ejection time

  16. Accuracy and Resolution in Micro-earthquake Tomographic Inversion Studies

    NASA Astrophysics Data System (ADS)

    Hutchings, L. J.; Ryan, J.

    2010-12-01

    Accuracy and resolution are complimentary properties necessary to interpret the results of earthquake location and tomography studies. Accuracy is the how close an answer is to the “real world”, and resolution is who small of node spacing or earthquake error ellipse one can achieve. We have modified SimulPS (Thurber, 1986) in several ways to provide a tool for evaluating accuracy and resolution of potential micro-earthquake networks. First, we provide synthetic travel times from synthetic three-dimensional geologic models and earthquake locations. We use this to calculate errors in earthquake location and velocity inversion results when we perturb these models and try to invert to obtain these models. We create as many stations as desired and can create a synthetic velocity model with any desired node spacing. We apply this study to SimulPS and TomoDD inversion studies. “Real” travel times are perturbed with noise and hypocenters are perturbed to replicate a starting location away from the “true” location, and inversion is performed by each program. We establish travel times with the pseudo-bending ray tracer and use the same ray tracer in the inversion codes. This, of course, limits our ability to test the accuracy of the ray tracer. We developed relationships for the accuracy and resolution expected as a function of the number of earthquakes and recording stations for typical tomographic inversion studies. Velocity grid spacing started at 1km, then was decreased to 500m, 100m, 50m and finally 10m to see if resolution with decent accuracy at that scale was possible. We considered accuracy to be good when we could invert a velocity model perturbed by 50% back to within 5% of the original model, and resolution to be the size of the grid spacing. We found that 100 m resolution could obtained by using 120 stations with 500 events, bu this is our current limit. The limiting factors are the size of computers needed for the large arrays in the inversion and a

  17. Accuracy assessment in the Large Area Crop Inventory Experiment

    NASA Technical Reports Server (NTRS)

    Houston, A. G.; Pitts, D. E.; Feiveson, A. H.; Badhwar, G.; Ferguson, M.; Hsu, E.; Potter, J.; Chhikara, R.; Rader, M.; Ahlers, C.

    1979-01-01

    The Accuracy Assessment System (AAS) of the Large Area Crop Inventory Experiment (LACIE) was responsible for determining the accuracy and reliability of LACIE estimates of wheat production, area, and yield, made at regular intervals throughout the crop season, and for investigating the various LACIE error sources, quantifying these errors, and relating them to their causes. Some results of using the AAS during the three years of LACIE are reviewed. As the program culminated, AAS was able not only to meet the goal of obtaining accurate statistical estimates of sampling and classification accuracy, but also the goal of evaluating component labeling errors. Furthermore, the ground-truth data processing matured from collecting data for one crop (small grains) to collecting, quality-checking, and archiving data for all crops in a LACIE small segment.

  18. Land cover mapping of Greater Mesoamerica using MODIS data

    USGS Publications Warehouse

    Giri, Chandra; Jenkins, Clinton N.

    2005-01-01

    A new land cover database of Greater Mesoamerica has been prepared using moderate resolution imaging spectroradiometer (MODIS, 500 m resolution) satellite data. Daily surface reflectance MODIS data and a suite of ancillary data were used in preparing the database by employing a decision tree classification approach. The new land cover data are an improvement over traditional advanced very high resolution radiometer (AVHRR) based land cover data in terms of both spatial and thematic details. The dominant land cover type in Greater Mesoamerica is forest (39%), followed by shrubland (30%) and cropland (22%). Country analysis shows forest as the dominant land cover type in Belize (62%), Cost Rica (52%), Guatemala (53%), Honduras (56%), Nicaragua (53%), and Panama (48%), cropland as the dominant land cover type in El Salvador (60.5%), and shrubland as the dominant land cover type in Mexico (37%). A three-step approach was used to assess the quality of the classified land cover data: (i) qualitative assessment provided good insight in identifying and correcting gross errors; (ii) correlation analysis of MODIS- and Landsat-derived land cover data revealed strong positive association for forest (r2 = 0.88), shrubland (r2 = 0.75), and cropland (r2 = 0.97) but weak positive association for grassland (r2 = 0.26); and (iii) an error matrix generated using unseen training data provided an overall accuracy of 77.3% with a Kappa coefficient of 0.73608. Overall, MODIS 500 m data and the methodology used were found to be quite useful for broad-scale land cover mapping of Greater Mesoamerica.

  19. Diagnostic accuracy of MRI in the measurement of glenoid bone loss.

    PubMed

    Gyftopoulos, Soterios; Hasan, Saqib; Bencardino, Jenny; Mayo, Jason; Nayyar, Samir; Babb, James; Jazrawi, Laith

    2012-10-01

    The purpose of this study is to assess the accuracy of MRI quantification of glenoid bone loss and to compare the diagnostic accuracy of MRI to CT in the measurement of glenoid bone loss. MRI, CT, and 3D CT examinations of 18 cadaveric glenoids were obtained after the creation of defects along the anterior and anteroinferior glenoid. The defects were measured by three readers separately and blindly using the circle method. These measurements were compared with measurements made on digital photographic images of the cadaveric glenoids. Paired sample Student t tests were used to compare the imaging modalities. Concordance correlation coefficients were also calculated to measure interobserver agreement. Our data show that MRI could be used to accurately measure glenoid bone loss with a small margin of error (mean, 3.44%; range, 2.06-5.94%) in estimated percentage loss. MRI accuracy was similar to that of both CT and 3D CT for glenoid loss measurements in our study for the readers familiar with the circle method, with 1.3% as the maximum expected difference in accuracy of the percentage bone loss between the different modalities (95% confidence). Glenoid bone loss can be accurately measured on MRI using the circle method. The MRI quantification of glenoid bone loss compares favorably to measurements obtained using 3D CT and CT. The accuracy of the measurements correlates with the level of training, and a learning curve is expected before mastering this technique.

  20. Accuracies of genomically estimated breeding values from pure-breed and across-breed predictions in Australian beef cattle.

    PubMed

    Boerner, Vinzent; Johnston, David J; Tier, Bruce

    2014-10-24

    The major obstacles for the implementation of genomic selection in Australian beef cattle are the variety of breeds and in general, small numbers of genotyped and phenotyped individuals per breed. The Australian Beef Cooperative Research Center (Beef CRC) investigated these issues by deriving genomic prediction equations (PE) from a training set of animals that covers a range of breeds and crosses including Angus, Murray Grey, Shorthorn, Hereford, Brahman, Belmont Red, Santa Gertrudis and Tropical Composite. This paper presents accuracies of genomically estimated breeding values (GEBV) that were calculated from these PE in the commercial pure-breed beef cattle seed stock sector. PE derived by the Beef CRC from multi-breed and pure-breed training populations were applied to genotyped Angus, Limousin and Brahman sires and young animals, but with no pure-breed Limousin in the training population. The accuracy of the resulting GEBV was assessed by their genetic correlation to their phenotypic target trait in a bi-variate REML approach that models GEBV as trait observations. Accuracies of most GEBV for Angus and Brahman were between 0.1 and 0.4, with accuracies for abattoir carcass traits generally greater than for live animal body composition traits and reproduction traits. Estimated accuracies greater than 0.5 were only observed for Brahman abattoir carcass traits and for Angus carcass rib fat. Averaged across traits within breeds, accuracies of GEBV were highest when PE from the pooled across-breed training population were used. However, for the Angus and Brahman breeds the difference in accuracy from using pure-breed PE was small. For the Limousin breed no reasonable results could be achieved for any trait. Although accuracies were generally low compared to published accuracies estimated within breeds, they are in line with those derived in other multi-breed populations. Thus PE developed by the Beef CRC can contribute to the implementation of genomic selection in

  1. Effects of accuracy constraints on reach-to-grasp movements in cerebellar patients.

    PubMed

    Rand, M K; Shimansky, Y; Stelmach, G E; Bracha, V; Bloedel, J R

    2000-11-01

    Reach-to-grasp movements of patients with pathology restricted to the cerebellum were compared with those of normal controls. Two types of paradigms with different accuracy constraints were used to examine whether cerebellar impairment disrupts the stereotypic relationship between arm transport and grip aperture and whether the variability of this relationship is altered when greater accuracy is required. The movements were made to either a vertical dowel or to a cross bar of a small cross. All subjects were asked to reach for either target at a fast but comfortable speed, grasp the object between the index finger and thumb, and lift it a short distance off the table. In terms of the relationship between arm transport and grip aperture, the control subjects showed a high consistency in grip aperture and wrist velocity profiles from trial to trial for movements to both the dowel and the cross. The relationship between the maximum velocity of the wrist and the time at which grip aperture was maximal during the reach was highly consistent throughout the experiment. In contrast, the time of maximum grip aperture and maximum wrist velocity of the cerebellar patients was quite variable from trial to trial, and the relationship of these measurements also varied considerably. These abnormalities were present regardless of the accuracy requirement. In addition, the cerebellar patients required a significantly longer time to grasp and lift the objects than the control subjects. Furthermore, the patients exhibited a greater grip aperture during reach than the controls. These data indicate that the cerebellum contributes substantially to the coordination of movements required to perform reach-to-grasp movements. Specifically, the cerebellum is critical for executing this behavior with a consistent, well-timed relationship between the transport and grasp components. This contribution is apparent even when accuracy demands are minimal.

  2. Self-refraction accuracy with adjustable spectacles among children in Ghana.

    PubMed

    Ilechie, Alex Azuka; Abokyi, Samuel; Owusu-Ansah, Andrew; Boadi-Kusi, Samuel Bert; Denkyira, Andrew Kofi; Abraham, Carl Halladay

    2015-04-01

    To determine the accuracy of self-refraction (SR) in myopic teenagers, we compared visual and refractive outcomes of self-refracting spectacles (FocusSpecs) with those obtained using cycloplegic subjective refraction (CSR) as a gold standard. A total of 203 eligible schoolchildren (mean [±SD] age, 13.8 [±1.0] years; 59.1% were female) completed an examination consisting of SR with FocusSpecs adjustable spectacles, visual acuity with the logMAR (logarithm of the minimum angle of resolution) chart, cycloplegic retinoscopy, and CSR. Examiners were masked to the SR findings. Wilcoxon signed rank test and paired Student t test were used to compare measures across refraction methods (95% confidence intervals [CIs]). The mean (±SD) spherical equivalent refractive error measured by CSR and SR was -1.22 (±0.49) diopters (D) and -1.66 (±0.73) D, respectively, a statistically significant difference of -0.44 D (p < 0.001, t = 15.517). The greatest proportion of participants was correctable to visual acuity greater than or equal to 6/7.5 (logMAR 0.1) in the better eye by CSR (99.0%; 95% CI, 96.5 to 99.7%), followed by cycloplegic retinoscopy (94.1%; 95% CI, 90.0 to 96.6%) and SR (85.2%; 95% CI, 79.7 to 89.5%). These proportions differed significantly from each other (p < 0.001, Wilcoxon signed rank test). Myopic inaccuracy of greater than 0.50 D and greater than or equal to -1.00 D was present in 29 (15.3%) and 16 (8.4%) right eyes, respectively, with SR. In logistic regression models, failure to achieve visual acuity greater than or equal to 6/7.5 in right eyes with SR was significantly associated with age (odds ratio, 1.92; 95% CI, 1.12 to 3.28; p = 0.017) and spherical power (odds ratio, 0.017; 95% CI, 0.005 to 0.056; p < 0.001). Self-refraction offers acceptable visual and refractive results for young people in a rural setting in Ghana, although myopic inaccuracy in the more negative direction occurred in some children.

  3. The Theory and Practice of Estimating the Accuracy of Dynamic Flight-Determined Coefficients

    NASA Technical Reports Server (NTRS)

    Maine, R. E.; Iliff, K. W.

    1981-01-01

    Means of assessing the accuracy of maximum likelihood parameter estimates obtained from dynamic flight data are discussed. The most commonly used analytical predictors of accuracy are derived and compared from both statistical and simplified geometrics standpoints. The accuracy predictions are evaluated with real and simulated data, with an emphasis on practical considerations, such as modeling error. Improved computations of the Cramer-Rao bound to correct large discrepancies due to colored noise and modeling error are presented. The corrected Cramer-Rao bound is shown to be the best available analytical predictor of accuracy, and several practical examples of the use of the Cramer-Rao bound are given. Engineering judgement, aided by such analytical tools, is the final arbiter of accuracy estimation.

  4. Evaluating the accuracy of tooth color measurement by combining the Munsell color system and dental colorimeter.

    PubMed

    Chang, Jiun-Yao; Chen, Wen-Cheng; Huang, Ta-Ko; Wang, Jen-Chyan; Fu, Po-Sung; Chen, Jeng-Huey; Hung, Chun-Cheng

    2012-09-01

    As we pay increasing attention to dental aesthetics, tooth color matching has become an important part of daily dental practice. This aim of this study was to develop a method to enhance the accuracy of a tooth color matching machine. The Munsell color tabs in the range of natural human teeth were measured using a tooth color measuring machine (ShadeEye NCC). The machine's accuracy was analyzed using an analysis of variance test and a Tukey post-hoc test. When matching the Munsell color tabs with the ShadeEye NCC colorimeter, settings of Chroma greater than 6 and Value less than 4 showed unacceptable clinical results. When the CIELAB mode was used, the a* value (which represents the red-green axis in the Commission Internationale de l'Eclairage color space) made no significant difference (p=0.84), the L* value (which represents the lightness) resulted in a negative correlation, and the b* value (which represents the yellow-blue axis) resulted in a positive correlation with ΔE. When the Munsell color tabs and the Vitapan were measured in the same mode and compared, the inaccuracies showed that the Vitapan was not a proper tool for evaluating the stability and accuracy of ShadeEye NCC. By knowing the limitations of the machine, we evaluated the data using the Munsell color tabs; shade beyond the acceptable range should be reevaluated using a visual shade matching method, or if measured by another machine, this shade range should be covered to obtain more accurate results. Copyright © 2012. Published by Elsevier B.V.

  5. Is Industry Funding Associated with Greater Scholarly Impact Among Academic Neurosurgeons?

    PubMed

    Eloy, Jean Anderson; Kilic, Suat; Yoo, Nicholas G; Mcleod, Thomas; Svider, Peter F; Baredes, Soly; Folbe, Adam J; Couldwell, William T; Liu, James K

    2017-07-01

    To determine the relationship between industry payments and scholarly impact among academic neurosurgeons. Faculty names and academic rank data were obtained from department websites, bibliometric data were obtained from the Scopus database, and industry payment data were obtained from the Center for Medicare and Medicaid Services open payments database (openpayments.cms.gov). The h-index was used to estimate scholarly impact. Payments were classified as "general," "associated research," and "research payments." Subgroup analyses were done for academic rank, fellowship training, and sex. Among 1008 academic neurosurgeons, scholarly impact was greater among individuals receiving associated research industry support compared with those not receiving it. Scholarly impact also was greater among individuals who received more than $10,000 of any type of industry support compared with individuals who received less than that or no payment. This association also was seen in fellowship-trained surgeons. Female neurosurgeons were less likely than male neurosurgeons to get industry funding and were likely to get less funding. There is a strong association between associated research funding from industry and scholarly impact among academic neurosurgeons. It's unclear whether this association is a result of funding facilitating more research projects that eventually lead to more high-impact publications, if industry is providing more funding to academic neurosurgeons with greater scholarly impact, or whether it represents intrinsic academic activity among a group of neurosurgeons who are more likely to be academically productive and procure funding from all potential sources to increase this activity. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Accuracy and consistency of weights provided by home bathroom scales.

    PubMed

    Yorkin, Meredith; Spaccarotella, Kim; Martin-Biggers, Jennifer; Quick, Virginia; Byrd-Bredbenner, Carol

    2013-12-17

    Self-reported body weight is often used for calculation of Body Mass Index because it is easy to collect. Little is known about sources of error introduced by using bathroom scales to measure weight at home. The objective of this study was to evaluate the accuracy and consistency of digital versus dial-type bathroom scales commonly used for self-reported weight. Participants brought functioning bathroom scales (n=18 dial-type, n=43 digital-type) to a central location. Trained researchers assessed accuracy and consistency using certified calibration weights at 10 kg, 25 kg, 50 kg, 75 kg, 100 kg, and 110 kg. Data also were collected on frequency of calibration, age and floor surface beneath the scale. All participants reported using their scale on hard surface flooring. Before calibration, all digital scales displayed 0, but dial scales displayed a mean absolute initial weight of 0.95 (1.9 SD) kg. Digital scales accurately weighed test loads whereas dial-type scale weights differed significantly (p<0.05). Imprecision of dial scales was significantly greater than that of digital scales at all weights (p<0.05). Accuracy and precision did not vary by scale age. Digital home bathroom scales provide sufficiently accurate and consistent weights for public health research. Reminders to zero scales before each use may further improve accuracy of self-reported weight.

  7. The assessment of accuracy of inner shapes manufactured by FDM

    NASA Astrophysics Data System (ADS)

    Gapiński, Bartosz; Wieczorowski, Michał; Båk, Agata; Domínguez, Alejandro Pereira; Mathia, Thomas

    2018-05-01

    3D printing created a totally new manufacturing possibilities. It is possible e.g. to produce closed inner shapes with different geometrical features. Unfortunately traditional methods are not suitable to verify the manufacturing accuracy, because it would be necessary to cut workpieces. In the paper the possibilities of computed tomography (x-ray micro-CT) application for accuracy assessment of inner shapes are presented. This was already reported in some papers. For research works hollow cylindrical samples with 20mm diameter and 300mm length were manufactured by means of FDM. A sphere, cone and cube were put inside these elements. All measurements were made with the application of CT. The measurement results enable us to obtain a full geometrical image of both inner and outer surfaces of a cylinder as well as shapes of inner elements. Additionally, it is possible to inspect the structure of a printed element - size and location of supporting net and all the other supporting elements necessary to hold up the walls created over empty spaces. The results obtained with this method were compared with CAD models which were a source of data for 3D printing. This in turn made it possible to assess the manufacturing accuracy of particular figures inserted into the cylinders. The influence of location of the inner supporting walls on a shape deformation was also investigated. The results obtained with this way show us how important CT can be during the assessment of 3D printing of objects.

  8. Accuracy Study of a 2-Component Point Doppler Velocimeter (PDV)

    NASA Technical Reports Server (NTRS)

    Kuhlman, John; Naylor, Steve; James, Kelly; Ramanath, Senthil

    1997-01-01

    A two-component Point Doppler Velocimeter (PDV) which has recently been developed is described, and a series of velocity measurements which have been obtained to quantify the accuracy of the PDV system are summarized. This PDV system uses molecular iodine vapor cells as frequency discriminating filters to determine the Doppler shift of laser light which is scattered off of seed particles in a flow. The majority of results which have been obtained to date are for the mean velocity of a rotating wheel, although preliminary data are described for fully-developed turbulent pipe flow. Accuracy of the present wheel velocity data is approximately +/- 1 % of full scale, while linearity of a single channel is on the order of +/- 0.5 % (i.e., +/- 0.6 m/sec and +/- 0.3 m/sec, out of 57 m/sec, respectively). The observed linearity of these results is on the order of the accuracy to which the speed of the rotating wheel has been set for individual data readings. The absolute accuracy of the rotating wheel data is shown to be consistent with the level of repeatability of the cell calibrations. The preliminary turbulent pipe flow data show consistent turbulence intensity values, and mean axial velocity profiles generally agree with pitot probe data. However, there is at present an offset error in the radial velocity which is on the order of 5-10 % of the mean axial velocity.

  9. Observations of territorial breeding common ravens caching eggs of greater sage-grouse

    USGS Publications Warehouse

    Howe, Kristy B.; Coates, Peter S.

    2015-01-01

    Previous investigations using continuous video monitoring of greater sage-grouse Centrocercus urophasianus nests have unambiguously identified common ravens Corvus corax as an important egg predator within the western United States. The quantity of greater sage-grouse eggs an individual common raven consumes during the nesting period and the extent to which common ravens actively hunt greater sage-grouse nests are largely unknown. However, some evidence suggests that territorial breeding common ravens, rather than nonbreeding transients, are most likely responsible for nest depredations. We describe greater sage-grouse egg depredation observations obtained opportunistically from three common raven nests located in Idaho and Nevada where depredated greater sage-grouse eggs were found at or in the immediate vicinity of the nest site, including the caching of eggs in nearby rock crevices. We opportunistically monitored these nests by counting and removing depredated eggs and shell fragments from the nest sites during each visit to determine the extent to which the common raven pairs preyed on greater sage-grouse eggs. To our knowledge, our observations represent the first evidence that breeding, territorial pairs of common ravens cache greater sage-grouse eggs and are capable of depredating multiple greater sage-grouse nests.

  10. Optimizing care of ventilated infants by improving weighing accuracy on incubator scales.

    PubMed

    El-Kafrawy, Ula; Taylor, R J

    2016-01-01

    To determine the accuracy of weighing ventilated infants on incubator scales and whether the accuracy can be improved by the addition of a ventilator tube compensator (VTC) device to counterbalance the force exerted by the ventilator tubing. Body weights on integral incubator scales were compared in ventilated infants (with and without a VTC), with body weights on standalone electronic scales (true weight). Individual and series of trend weights were obtained on the infants. The method of Bland and Altman was used to assess the introduced bias. The study included 60 ventilated infants; 66% of them weighed <1000 g. A total of 102 paired-weight datasets for 30 infants undergoing conventional ventilation and 30 undergoing high frequency oscillator ventilation (HFOV) supported by a SensorMedics oscillator, (with and without a VTC) were obtained. The mean differences and (95% CI for the bias) between the integral and true scale weighing methods was 60.8 g (49.1 g to 72.5 g) without and -2.8 g (-8.9 g to 3.3 g) with a VTC in HFOV infants; 41.0 g (32.1 g to 50.0 g) without and -5.1 g (-9.3 g to -0.8 g) with a VTC for conventionally ventilated infants. Differences of greater than 2% were considered clinically relevant and occurred in 93.8% without and 20.8% with a VTC in HFOV infants and 81.5% without and 27.8% with VTC in conventionally ventilated infants. The use of the VTC device represents a substantial improvement on the current practice for weighing ventilated infants, particularly in the extreme preterm infants where an over- or underestimated weight can have important clinical implications for treatment. A large-scale clinical trial to validate these findings is needed.

  11. Martial arts striking hand peak acceleration, accuracy and consistency.

    PubMed

    Neto, Osmar Pinto; Marzullo, Ana Carolina De Miranda; Bolander, Richard P; Bir, Cynthia A

    2013-01-01

    The goal of this paper was to investigate the possible trade-off between peak hand acceleration and accuracy and consistency of hand strikes performed by martial artists of different training experiences. Ten male martial artists with training experience ranging from one to nine years volunteered to participate in the experiment. Each participant performed 12 maximum effort goal-directed strikes. Hand acceleration during the strikes was obtained using a tri-axial accelerometer block. A pressure sensor matrix was used to determine the accuracy and consistency of the strikes. Accuracy was estimated by the radial distance between the centroid of each subject's 12 strikes and the target, whereas consistency was estimated by the square root of the 12 strikes mean squared distance from their centroid. We found that training experience was significantly correlated to hand peak acceleration prior to impact (r(2)=0.456, p =0.032) and accuracy (r(2)=0. 621, p=0.012). These correlations suggest that more experienced participants exhibited higher hand peak accelerations and at the same time were more accurate. Training experience, however, was not correlated to consistency (r(2)=0.085, p=0.413). Overall, our results suggest that martial arts training may lead practitioners to achieve higher striking hand accelerations with better accuracy and no change in striking consistency.

  12. Regional Anatomical Observation of Morphology of Greater Palatine Canal and Surrounding Structures.

    PubMed

    Suzuki, Masashi; Omine, Yuya; Shimoo, Yoshiaki; Yamamoto, Masahito; Kaketa, Akihiro; Kasahara, Masaaki; Serikawa, Masamitu; Rhee, Sunki; Matsubayashi, Tadatoshi; Matsunaga, Satoru; Abe, Shinichi

    2016-01-01

    In maxillary molar region implant therapy, support is sometimes obtained from trabecular bone comprising the maxillary tuberosity, pterygoid process of the sphenoid bone, and pyramidal process of the palatine bone. Great care is necessary in such cases due to the presence of the greater palatine canal, which forms a passageway for the greater palatine artery, vein, and nerve. However, clinical anatomical reports envisioning embedding of pterygomaxillary implants in this trabecular bone region have been limited in number. In this study, the 3-D morphology of the greater palatine canal region, including the maxillary tuberosity region and points requiring particular care in pterygomaxillary implantation, were therefore investigated. Micro-CT was used to image 20 dentulous jaws (40 sides) harvested from the dry skulls of Japanese individuals with a mean age of 28.2 years at time of death. The skulls were obtained from the Jikei University School of Medicine cadaver repository. Three-dimensional reconstruction of the trabecular bone region, including the greater palatine canal, was performed using software for 3-D measurement of trabecular bone structure. Trabecular bone region morphometry was performed with the hamular notch-incisive papilla (HIP) plane as the reference plane. The results showed a truncated-cone structure with the greater palatine foramen as the base extending to the pterygopalatine fossa. This indicates the need for care with respect to proximity of the dental implant body to the greater palatine canal and the risk of perforation if it is embedded in the maxillary tuberosity region at an inclination of 60° toward the lingual side. Moreover, caution must be exercised to avoid possible damage to the medial wall of the maxillary sinus if the inclination of the embedded dental implant body is almost perpendicular to the HIP plane.

  13. An evaluation of the accuracy of geomagnetic data obtained from an unattended, automated, quasi-absolute station

    USGS Publications Warehouse

    Herzog, D.C.

    1990-01-01

    A comparison is made of geomagnetic calibration data obtained from a high-sensitivity proton magnetometer enclosed within an orthogonal bias coil system, with data obtained from standard procedures at a mid-latitude U.S. Geological Survey magnetic observatory using a quartz horizontal magnetometer, a Ruska magnetometer, and a total field magnetometer. The orthogonal coil arrangement is used with the proton magnetometer to provide Deflected-Inclination-Deflected-Declination (DIDD) data from which quasi-absolute values of declination, horizontal intensity, and vertical intensity can be derived. Vector magnetometers provide the ordinate values to yield baseline calibrations for both the DIDD and standard observatory processes. Results obtained from a prototype system over a period of several months indicate that the DIDD unit can furnish adequate absolute field values for maintaining observatory calibration data, thus providing baseline control for unattended, remote stations. ?? 1990.

  14. The effect of speed-accuracy strategy on response interference control in Parkinson's disease.

    PubMed

    Wylie, S A; van den Wildenberg, W P M; Ridderinkhof, K R; Bashore, T R; Powell, V D; Manning, C A; Wooten, G F

    2009-07-01

    Studies that used conflict paradigms such as the Eriksen Flanker task show that many individuals with Parkinson's disease (PD) have pronounced difficulty resolving the conflict that arises from the simultaneous activation of mutually exclusive responses. This finding fits well with contemporary views that postulate a key role for the basal ganglia in action selection. The present experiment aims to specify the cognitive processes that underlie action selection deficits among PD patients in the context of variations in speed-accuracy strategy. PD patients (n=28) and healthy controls (n=17) performed an arrow version of the flanker task under task instructions that either emphasized speed or accuracy of responses. Reaction time (RT) and accuracy rates decreased with speed compared to accuracy instructions, although to a lesser extent for the PD group. Differences in flanker interference effects among PD and healthy controls depended on speed-accuracy strategy. Compared to the healthy controls, PD patients showed larger flanker interference effects under speed stress. RT distribution analyses suggested that PD patients have greater difficulty suppressing incorrect response activation when pressing for speed. These initial findings point to an important interaction between strategic and computational aspects of interference control in accounting for cognitive impairments of PD. The results are also compatible with recent brain imaging studies that demonstrate basal ganglia activity to co-vary with speed-accuracy adjustments.

  15. Compact Intraoperative MRI: Stereotactic Accuracy and Future Directions.

    PubMed

    Markowitz, Daniel; Lin, Dishen; Salas, Sussan; Kohn, Nina; Schulder, Michael

    2017-01-01

    Intraoperative imaging must supply data that can be used for accurate stereotactic navigation. This information should be at least as accurate as that acquired from diagnostic imagers. The aim of this study was to compare the stereotactic accuracy of an updated compact intraoperative MRI (iMRI) device based on a 0.15-T magnet to standard surgical navigation on a 1.5-T diagnostic scan MRI and to navigation with an earlier model of the same system. The accuracy of each system was assessed using a water-filled phantom model of the brain. Data collected with the new system were compared to those obtained in a previous study assessing the older system. The accuracy of the new iMRI was measured against standard surgical navigation on a 1.5-T MRI using T1-weighted (W) images. The mean error with the iMRI using T1W images was lower than that based on images from the 1.5-T scan (1.24 vs. 2.43 mm). T2W images from the newer iMRI yielded a lower navigation error than those acquired with the prior model (1.28 vs. 3.15 mm). Improvements in magnet design can yield progressive increases in accuracy, validating the concept of compact, low-field iMRI. Avoiding the need for registration between image and surgical space increases navigation accuracy. © 2017 S. Karger AG, Basel.

  16. Improvement in Rayleigh Scattering Measurement Accuracy

    NASA Technical Reports Server (NTRS)

    Fagan, Amy F.; Clem, Michelle M.; Elam, Kristie A.

    2012-01-01

    Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous velocity, density, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of an acousto-optic frequency shifting device to improve measurement accuracy in Rayleigh scattering experiments at the NASA Glenn Research Center. The frequency shifting device is used as a means of shifting the incident or reference laser frequency by 1100 MHz to avoid overlap of the Rayleigh and reference signal peaks in the interference pattern used to obtain the velocity, density, and temperature measurements, and also to calibrate the free spectral range of the Fabry-Perot etalon. The measurement accuracy improvement is evaluated by comparison of Rayleigh scattering measurements acquired with and without shifting of the reference signal frequency in a 10 mm diameter subsonic nozzle flow.

  17. Precision and accuracy of age estimates obtained from anal fin spines, dorsal fin spines, and sagittal otoliths for known-age largemouth bass

    USGS Publications Warehouse

    Klein, Zachary B.; Bonvechio, Timothy F.; Bowen, Bryant R.; Quist, Michael C.

    2017-01-01

    Sagittal otoliths are the preferred aging structure for Micropterus spp. (black basses) in North America because of the accurate and precise results produced. Typically, fisheries managers are hesitant to use lethal aging techniques (e.g., otoliths) to age rare species, trophy-size fish, or when sampling in small impoundments where populations are small. Therefore, we sought to evaluate the precision and accuracy of 2 non-lethal aging structures (i.e., anal fin spines, dorsal fin spines) in comparison to that of sagittal otoliths from known-age Micropterus salmoides (Largemouth Bass; n = 87) collected from the Ocmulgee Public Fishing Area, GA. Sagittal otoliths exhibited the highest concordance with true ages of all structures evaluated (coefficient of variation = 1.2; percent agreement = 91.9). Similarly, the low coefficient of variation (0.0) and high between-reader agreement (100%) indicate that age estimates obtained from sagittal otoliths were the most precise. Relatively high agreement between readers for anal fin spines (84%) and dorsal fin spines (81%) suggested the structures were relatively precise. However, age estimates from anal fin spines and dorsal fin spines exhibited low concordance with true ages. Although use of sagittal otoliths is a lethal technique, this method will likely remain the standard for aging Largemouth Bass and other similar black bass species.

  18. Maltreated children's memory: accuracy, suggestibility, and psychopathology.

    PubMed

    Eisen, Mitchell L; Goodman, Gail S; Qin, Jianjian; Davis, Suzanne; Crayton, John

    2007-11-01

    Memory, suggestibility, stress arousal, and trauma-related psychopathology were examined in 328 3- to 16-year-olds involved in forensic investigations of abuse and neglect. Children's memory and suggestibility were assessed for a medical examination and venipuncture. Being older and scoring higher in cognitive functioning were related to fewer inaccuracies. In addition, cortisol level and trauma symptoms in children who reported more dissociative tendencies were associated with increased memory error, whereas cortisol level and trauma symptoms were not associated with increased error for children who reported fewer dissociative tendencies. Sexual and/or physical abuse predicted greater accuracy. The study contributes important new information to scientific understanding of maltreatment, psychopathology, and eyewitness memory in children. (c) 2007 APA.

  19. An accuracy assessment of positions obtained using survey- and recreational-grade Global Positioning System receivers across a range of forest conditions within the Tanana Valley of interior Alaska

    Treesearch

    Hans-Erik Andersen; Tobey Clarkin; Ken Winterberger; Jacob Strunk

    2009-01-01

    The accuracy of recreational- and survey-grade global positioning system (GPS) receivers was evaluated across a range of forest conditions in the Tanana Valley of interior Alaska. High-accuracy check points, established using high-order instruments and closed-traverse surveying methods, were then used to evaluate the accuracy of positions acquired in different forest...

  20. The use of low density high accuracy (LDHA) data for correction of high density low accuracy (HDLA) point cloud

    NASA Astrophysics Data System (ADS)

    Rak, Michal Bartosz; Wozniak, Adam; Mayer, J. R. R.

    2016-06-01

    Coordinate measuring techniques rely on computer processing of coordinate values of points gathered from physical surfaces using contact or non-contact methods. Contact measurements are characterized by low density and high accuracy. On the other hand optical methods gather high density data of the whole object in a short time but with accuracy at least one order of magnitude lower than for contact measurements. Thus the drawback of contact methods is low density of data, while for non-contact methods it is low accuracy. In this paper a method for fusion of data from two measurements of fundamentally different nature: high density low accuracy (HDLA) and low density high accuracy (LDHA) is presented to overcome the limitations of both measuring methods. In the proposed method the concept of virtual markers is used to find a representation of pairs of corresponding characteristic points in both sets of data. In each pair the coordinates of the point from contact measurements is treated as a reference for the corresponding point from non-contact measurement. Transformation enabling displacement of characteristic points from optical measurement to their match from contact measurements is determined and applied to the whole point cloud. The efficiency of the proposed algorithm was evaluated by comparison with data from a coordinate measuring machine (CMM). Three surfaces were used for this evaluation: plane, turbine blade and engine cover. For the planar surface the achieved improvement was of around 200 μm. Similar results were obtained for the turbine blade but for the engine cover the improvement was smaller. For both freeform surfaces the improvement was higher for raw data than for data after creation of mesh of triangles.

  1. An accuracy assessment of Cartesian-mesh approaches for the Euler equations

    NASA Technical Reports Server (NTRS)

    Coirier, William J.; Powell, Kenneth G.

    1995-01-01

    A critical assessment of the accuracy of Cartesian-mesh approaches for steady, transonic solutions of the Euler equations of gas dynamics is made. An exact solution of the Euler equations (Ringleb's flow) is used not only to infer the order of the truncation error of the Cartesian-mesh approaches, but also to compare the magnitude of the discrete error directly to that obtained with a structured mesh approach. Uniformly and adaptively refined solutions using a Cartesian-mesh approach are obtained and compared to each other and to uniformly refined structured mesh results. The effect of cell merging is investigated as well as the use of two different K-exact reconstruction procedures. The solution methodology of the schemes is explained and tabulated results are presented to compare the solution accuracies.

  2. Global accuracy estimates of point and mean undulation differences obtained from gravity disturbances, gravity anomalies and potential coefficients

    NASA Technical Reports Server (NTRS)

    Jekeli, C.

    1979-01-01

    Through the method of truncation functions, the oceanic geoid undulation is divided into two constituents: an inner zone contribution expressed as an integral of surface gravity disturbances over a spherical cap; and an outer zone contribution derived from a finite set of potential harmonic coefficients. Global, average error estimates are formulated for undulation differences, thereby providing accuracies for a relative geoid. The error analysis focuses on the outer zone contribution for which the potential coefficient errors are modeled. The method of computing undulations based on gravity disturbance data for the inner zone is compared to the similar, conventional method which presupposes gravity anomaly data within this zone.

  3. Estimation of accuracy of earth-rotation parameters in different frequency bands

    NASA Astrophysics Data System (ADS)

    Vondrak, J.

    1986-11-01

    The accuracies of earth-rotation parameters as determined by five different observational techniques now available (i.e., optical astrometry /OA/, Doppler tracking of satellites /DTS/, satellite laser ranging /SLR/, very long-base interferometry /VLBI/ and lunar laser ranging /LLR/) are estimated. The differences between the individual techniques in all possible combinations, separated by appropriate filters into three frequency bands, were used to estimate the accuracies of the techniques for periods from 0 to 200 days, from 200 to 1000 days and longer than 1000 days. It is shown that for polar motion the most accurate results are obtained with VLBI anad SLR, especially in the short-period region; OA and DTS are less accurate, but with longer periods the differences in accuracy are less pronounced. The accuracies of UTI-UTC as determined by OA, VLBI and LLR are practically equivalent, the differences being less than 40 percent.

  4. An accuracy measurement method for star trackers based on direct astronomic observation

    PubMed Central

    Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping

    2016-01-01

    Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers. PMID:26948412

  5. An accuracy measurement method for star trackers based on direct astronomic observation.

    PubMed

    Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping

    2016-03-07

    Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers.

  6. Gains in accuracy from averaging ratings of abnormality

    NASA Astrophysics Data System (ADS)

    Swensson, Richard G.; King, Jill L.; Gur, David; Good, Walter F.

    1999-05-01

    Six radiologists used continuous scales to rate 529 chest-film cases for likelihood of five separate types of abnormalities (interstitial disease, nodules, pneumothorax, alveolar infiltrates and rib fractures) in each of six replicated readings, yielding 36 separate ratings of each case for the five abnormalities. Analyses for each type of abnormality estimated the relative gains in accuracy (area below the ROC curve) obtained by averaging the case-ratings across: (1) six independent replications by each reader (30% gain), (2) six different readers within each replication (39% gain) or (3) all 36 readings (58% gain). Although accuracy differed among both readers and abnormalities, ROC curves for the median ratings showed similar relative gains in accuracy. From a latent-variable model for these gains, we estimate that about 51% of a reader's total decision variance consisted of random (within-reader) errors that were uncorrelated between replications, another 14% came from that reader's consistent (but idiosyncratic) responses to different cases, and only about 35% could be attributed to systematic variations among the sampled cases that were consistent across different readers.

  7. On Accuracy of Adaptive Grid Methods for Captured Shocks

    NASA Technical Reports Server (NTRS)

    Yamaleev, Nail K.; Carpenter, Mark H.

    2002-01-01

    The accuracy of two grid adaptation strategies, grid redistribution and local grid refinement, is examined by solving the 2-D Euler equations for the supersonic steady flow around a cylinder. Second- and fourth-order linear finite difference shock-capturing schemes, based on the Lax-Friedrichs flux splitting, are used to discretize the governing equations. The grid refinement study shows that for the second-order scheme, neither grid adaptation strategy improves the numerical solution accuracy compared to that calculated on a uniform grid with the same number of grid points. For the fourth-order scheme, the dominant first-order error component is reduced by the grid adaptation, while the design-order error component drastically increases because of the grid nonuniformity. As a result, both grid adaptation techniques improve the numerical solution accuracy only on the coarsest mesh or on very fine grids that are seldom found in practical applications because of the computational cost involved. Similar error behavior has been obtained for the pressure integral across the shock. A simple analysis shows that both grid adaptation strategies are not without penalties in the numerical solution accuracy. Based on these results, a new grid adaptation criterion for captured shocks is proposed.

  8. The diagnostic accuracy of multiparametric MRI to determine pediatric brain tumor grades and types.

    PubMed

    Koob, Mériam; Girard, Nadine; Ghattas, Badih; Fellah, Slim; Confort-Gouny, Sylviane; Figarella-Branger, Dominique; Scavarda, Didier

    2016-04-01

    Childhood brain tumors show great histological variability. The goal of this retrospective study was to assess the diagnostic accuracy of multimodal MR imaging (diffusion, perfusion, MR spectroscopy) in the distinction of pediatric brain tumor grades and types. Seventy-six patients (range 1 month to 18 years) with brain tumors underwent multimodal MR imaging. Tumors were categorized by grade (I-IV) and by histological type (A-H). Multivariate statistical analysis was performed to evaluate the diagnostic accuracy of single and combined MR modalities, and of single imaging parameters to distinguish the different groups. The highest diagnostic accuracy for tumor grading was obtained with diffusion-perfusion (73.24%) and for tumor typing with diffusion-perfusion-MR spectroscopy (55.76%). The best diagnostic accuracy was obtained for tumor grading in I and IV and for tumor typing in embryonal tumor and pilocytic astrocytoma. Poor accuracy was seen in other grades and types. ADC and rADC were the best parameters for tumor grading and typing followed by choline level with an intermediate echo time, CBV for grading and Tmax for typing. Multiparametric MR imaging can be accurate in determining tumor grades (primarily grades I and IV) and types (mainly pilocytic astrocytomas and embryonal tumors) in children.

  9. High-accuracy contouring using projection moiré

    NASA Astrophysics Data System (ADS)

    Sciammarella, Cesar A.; Lamberti, Luciano; Sciammarella, Federico M.

    2005-09-01

    Shadow and projection moiré are the oldest forms of moiré to be used in actual technical applications. In spite of this fact and the extensive number of papers that have been published on this topic, the use of shadow moiré as an accurate tool that can compete with alternative devices poses very many problems that go to the very essence of the mathematical models used to obtain contour information from fringe pattern data. In this paper some recent developments on the projection moiré method are presented. Comparisons between the results obtained with the projection method and the results obtained by mechanical devices that operate with contact probes are presented. These results show that the use of projection moiré makes it possible to achieve the same accuracy that current mechanical touch probe devices can provide.

  10. Impact of Glucose Measurement Processing Delays on Clinical Accuracy and Relevance

    PubMed Central

    Jangam, Sujit R.; Hayter, Gary; Dunn, Timothy C.

    2013-01-01

    Background In a hospital setting, glucose is often measured from venous blood in the clinical laboratory. However, laboratory glucose measurements are typically not available in real time. In practice, turn-around times for laboratory measurements can be minutes to hours. This analysis assesses the impact of turn-around time on the effective clinical accuracy of laboratory measurements. Methods Data obtained from an earlier study with 58 subjects with type 1 diabetes mellitus (T1DM) were used for this analysis. In the study, glucose measurements using a YSI glucose analyzer were obtained from venous blood samples every 15 min while the subjects were at the health care facility. To simulate delayed laboratory results, each YSI glucose value from a subject was paired with one from a later time point (from the same subject) separated by 15, 30, 45, and 60 min. To assess the clinical accuracy of a delayed YSI result relative to a real-time result, the percentage of YSI pairs that meet the International Organization for Standardization (ISO) 15197:2003(E) standard for glucose measurement accuracy (±15 mg/dl for blood glucose < 75 mg/dl, ±20% for blood glucose ≥ 75 mg/dl) was calculated. Results It was observed that delays of 15 min or more reduce clinical accuracy below the ISO 15197:2003(E) recommendation of 95%. The accuracy was less than 65% for delays of 60 min. Conclusion This analysis suggests that processing delays in glucose measurements reduce the clinical relevance of results in patients with T1DM and may similarly degrade the clinical value of measurements in other patient populations. PMID:23759399

  11. Impact of glucose measurement processing delays on clinical accuracy and relevance.

    PubMed

    Jangam, Sujit R; Hayter, Gary; Dunn, Timothy C

    2013-05-01

    In a hospital setting, glucose is often measured from venous blood in the clinical laboratory. However, laboratory glucose measurements are typically not available in real time. In practice, turn-around times for laboratory measurements can be minutes to hours. This analysis assesses the impact of turn-around time on the effective clinical accuracy of laboratory measurements. Data obtained from an earlier study with 58 subjects with type 1 diabetes mellitus (T1DM) were used for this analysis. In the study, glucose measurements using a YSI glucose analyzer were obtained from venous blood samples every 15 min while the subjects were at the health care facility. To simulate delayed laboratory results, each YSI glucose value from a subject was paired with one from a later time point (from the same subject) separated by 15, 30, 45, and 60 min. To assess the clinical accuracy of a delayed YSI result relative to a real-time result, the percentage of YSI pairs that meet the International Organization for Standardization (ISO) 15197:2003(E) standard for glucose measurement accuracy (±15 mg/dl for blood glucose < 75 mg/dl, ±20% for blood glucose ≥ 75 mg/dl) was calculated. It was observed that delays of 15 min or more reduce clinical accuracy below the ISO 15197:2003(E) recommendation of 95%. The accuracy was less than 65% for delays of 60 min. This analysis suggests that processing delays in glucose measurements reduce the clinical relevance of results in patients with T1DM and may similarly degrade the clinical value of measurements in other patient populations. © 2013 Diabetes Technology Society.

  12. Accuracy and consistency of weights provided by home bathroom scales

    PubMed Central

    2013-01-01

    Background Self-reported body weight is often used for calculation of Body Mass Index because it is easy to collect. Little is known about sources of error introduced by using bathroom scales to measure weight at home. The objective of this study was to evaluate the accuracy and consistency of digital versus dial-type bathroom scales commonly used for self-reported weight. Methods Participants brought functioning bathroom scales (n = 18 dial-type, n = 43 digital-type) to a central location. Trained researchers assessed accuracy and consistency using certified calibration weights at 10 kg, 25 kg, 50 kg, 75 kg, 100 kg, and 110 kg. Data also were collected on frequency of calibration, age and floor surface beneath the scale. Results All participants reported using their scale on hard surface flooring. Before calibration, all digital scales displayed 0, but dial scales displayed a mean absolute initial weight of 0.95 (1.9 SD) kg. Digital scales accurately weighed test loads whereas dial-type scale weights differed significantly (p < 0.05). Imprecision of dial scales was significantly greater than that of digital scales at all weights (p < 0.05). Accuracy and precision did not vary by scale age. Conclusions Digital home bathroom scales provide sufficiently accurate and consistent weights for public health research. Reminders to zero scales before each use may further improve accuracy of self-reported weight. PMID:24341761

  13. The shared neural basis of empathy and facial imitation accuracy.

    PubMed

    Braadbaart, L; de Grauw, H; Perrett, D I; Waiter, G D; Williams, J H G

    2014-01-01

    Empathy involves experiencing emotion vicariously, and understanding the reasons for those emotions. It may be served partly by a motor simulation function, and therefore share a neural basis with imitation (as opposed to mimicry), as both involve sensorimotor representations of intentions based on perceptions of others' actions. We recently showed a correlation between imitation accuracy and Empathy Quotient (EQ) using a facial imitation task and hypothesised that this relationship would be mediated by the human mirror neuron system. During functional Magnetic Resonance Imaging (fMRI), 20 adults observed novel 'blends' of facial emotional expressions. According to instruction, they either imitated (i.e. matched) the expressions or executed alternative, pre-prescribed mismatched actions as control. Outside the scanner we replicated the association between imitation accuracy and EQ. During fMRI, activity was greater during mismatch compared to imitation, particularly in the bilateral insula. Activity during imitation correlated with EQ in somatosensory cortex, intraparietal sulcus and premotor cortex. Imitation accuracy correlated with activity in insula and areas serving motor control. Overlapping voxels for the accuracy and EQ correlations occurred in premotor cortex. We suggest that both empathy and facial imitation rely on formation of action plans (or a simulation of others' intentions) in the premotor cortex, in connection with representations of emotional expressions based in the somatosensory cortex. In addition, the insula may play a key role in the social regulation of facial expression. © 2013.

  14. The impact of training strategies on the accuracy of genomic predictors in United States Red Angus cattle.

    PubMed

    Lee, J; Kachman, S D; Spangler, M L

    2017-08-01

    resulted in higher accuracies of MBV than those obtained by DEPD for growth and carcass traits. When DEPD were used as the response variable, accuracies were greater for threshold traits and those that are sex limited, likely due to the fact that these traits suffer from a lack of information content and excluding animals in training with only parental information substantially decreases the training population size. It is recommended that the contribution of parental average to deregressed EPD should be removed in the construction of genomic prediction equations. The difference in terms of prediction accuracies between the 2 SNP panels or the number of folds compared herein was negligible.

  15. Knowledge discovery by accuracy maximization

    PubMed Central

    Cacciatore, Stefano; Luchinat, Claudio; Tenori, Leonardo

    2014-01-01

    Here we describe KODAMA (knowledge discovery by accuracy maximization), an unsupervised and semisupervised learning algorithm that performs feature extraction from noisy and high-dimensional data. Unlike other data mining methods, the peculiarity of KODAMA is that it is driven by an integrated procedure of cross-validation of the results. The discovery of a local manifold’s topology is led by a classifier through a Monte Carlo procedure of maximization of cross-validated predictive accuracy. Briefly, our approach differs from previous methods in that it has an integrated procedure of validation of the results. In this way, the method ensures the highest robustness of the obtained solution. This robustness is demonstrated on experimental datasets of gene expression and metabolomics, where KODAMA compares favorably with other existing feature extraction methods. KODAMA is then applied to an astronomical dataset, revealing unexpected features. Interesting and not easily predictable features are also found in the analysis of the State of the Union speeches by American presidents: KODAMA reveals an abrupt linguistic transition sharply separating all post-Reagan from all pre-Reagan speeches. The transition occurs during Reagan’s presidency and not from its beginning. PMID:24706821

  16. A New Three-Dimensional High-Accuracy Automatic Alignment System For Single-Mode Fibers

    NASA Astrophysics Data System (ADS)

    Yun-jiang, Rao; Shang-lian, Huang; Ping, Li; Yu-mei, Wen; Jun, Tang

    1990-02-01

    In order to achieve the low-loss splices of single-mode fibers, a new three-dimension high-accuracy automatic alignment system for single -mode fibers has been developed, which includes a new-type three-dimension high-resolution microdisplacement servo stage driven by piezoelectric elements, a new high-accuracy measurement system for the misalignment error of the fiber core-axis, and a special single chip microcomputer processing system. The experimental results show that alignment accuracy of ±0.1 pin with a movable stroke of -±20μm has been obtained. This new system has more advantages than that reported.

  17. Photogrammetric Accuracy and Modeling of Rolling Shutter Cameras

    NASA Astrophysics Data System (ADS)

    Vautherin, Jonas; Rutishauser, Simon; Schneider-Zapp, Klaus; Choi, Hon Fai; Chovancova, Venera; Glass, Alexis; Strecha, Christoph

    2016-06-01

    Unmanned aerial vehicles (UAVs) are becoming increasingly popular in professional mapping for stockpile analysis, construction site monitoring, and many other applications. Due to their robustness and competitive pricing, consumer UAVs are used more and more for these applications, but they are usually equipped with rolling shutter cameras. This is a significant obstacle when it comes to extracting high accuracy measurements using available photogrammetry software packages. In this paper, we evaluate the impact of the rolling shutter cameras of typical consumer UAVs on the accuracy of a 3D reconstruction. Hereto, we use a beta-version of the Pix4Dmapper 2.1 software to compare traditional (non rolling shutter) camera models against a newly implemented rolling shutter model with respect to both the accuracy of geo-referenced validation points and to the quality of the motion estimation. Multiple datasets have been acquired using popular quadrocopters (DJI Phantom 2 Vision+, DJI Inspire 1 and 3DR Solo) following a grid flight plan. For comparison, we acquired a dataset using a professional mapping drone (senseFly eBee) equipped with a global shutter camera. The bundle block adjustment of each dataset shows a significant accuracy improvement on validation ground control points when applying the new rolling shutter camera model for flights at higher speed (8m=s). Competitive accuracies can be obtained by using the rolling shutter model, although global shutter cameras are still superior. Furthermore, we are able to show that the speed of the drone (and its direction) can be solely estimated from the rolling shutter effect of the camera.

  18. Kinematic Visual Biofeedback Improves Accuracy of Learning a Swallowing Maneuver and Accuracy of Clinician Cues During Training.

    PubMed

    Azola, Alba M; Sunday, Kirstyn L; Humbert, Ianessa A

    2017-02-01

    Submental surface electromyography (ssEMG) visual biofeedback is widely used to train swallowing maneuvers. This study compares the effect of ssEMG and videofluoroscopy (VF) visual biofeedback on hyo-laryngeal accuracy when training a swallowing maneuver. Furthermore, it examines the clinician's ability to provide accurate verbal cues during swallowing maneuver training. Thirty healthy adults performed the volitional laryngeal vestibule closure maneuver (vLVC), which involves swallowing and sustaining closure of the laryngeal vestibule for 2 s. The study included two stages: (1) first accurate demonstration of the vLVC maneuver, followed by (2) training-20 vLVC training swallows. Participants were randomized into three groups: (a) ssEMG biofeedback only, (b) VF biofeedback only, and (c) mixed biofeedback (VF for the first accurate demonstration achieving stage and ssEMG for the training stage). Participants' performances were verbally critiqued or reinforced in real time while both the clinician and participant were observing the assigned visual biofeedback. VF and ssEMG were continuously recorded for all participants. Results show that accuracy of both vLVC performance and clinician cues was greater with VF biofeedback than with either ssEMG or mixed biofeedback (p < 0.001). Using ssEMG for providing real-time biofeedback during training could lead to errors while learning and training a swallowing maneuver.

  19. Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists

    PubMed Central

    Barlow, William E.; Chi, Chen; Carney, Patricia A.; Taplin, Stephen H.; D’Orsi, Carl; Cutter, Gary; Hendrick, R. Edward; Elmore, Joann G.

    2011-01-01

    Background Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. Methods Screening mammograms (n = 469 512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. Results Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (≤1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001–2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001–2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. Conclusions We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity

  20. Investigation on the Accuracy of Superposition Predictions of Film Cooling Effectiveness

    NASA Astrophysics Data System (ADS)

    Meng, Tong; Zhu, Hui-ren; Liu, Cun-liang; Wei, Jian-sheng

    2018-05-01

    Film cooling effectiveness on flat plates with double rows of holes has been studied experimentally and numerically in this paper. This configuration is widely used to simulate the multi-row film cooling on turbine vane. Film cooling effectiveness of double rows of holes and each single row was used to study the accuracy of superposition predictions. Method of stable infrared measurement technique was used to measure the surface temperature on the flat plate. This paper analyzed the factors that affect the film cooling effectiveness including hole shape, hole arrangement, row-to-row spacing and blowing ratio. Numerical simulations were performed to analyze the flow structure and film cooling mechanisms between each film cooling row. Results show that the blowing ratio within the range of 0.5 to 2 has a significant influence on the accuracy of superposition predictions. At low blowing ratios, results obtained by superposition method agree well with the experimental data. While at high blowing ratios, the accuracy of superposition prediction decreases. Another significant factor is hole arrangement. Results obtained by superposition prediction are nearly the same as experimental values of staggered arrangement structures. For in-line configurations, the superposition values of film cooling effectiveness are much higher than experimental data. For different hole shapes, the accuracy of superposition predictions on converging-expanding holes is better than cylinder holes and compound angle holes. For two different hole spacing structures in this paper, predictions show good agreement with the experiment results.

  1. Accuracy of predicting genomic breeding values for residual feed intake in Angus and Charolais beef cattle.

    PubMed

    Chen, L; Schenkel, F; Vinsky, M; Crews, D H; Li, C

    2013-10-01

    In beef cattle, phenotypic data that are difficult and/or costly to measure, such as feed efficiency, and DNA marker genotypes are usually available on a small number of animals of different breeds or populations. To achieve a maximal accuracy of genomic prediction using the phenotype and genotype data, strategies for forming a training population to predict genomic breeding values (GEBV) of the selection candidates need to be evaluated. In this study, we examined the accuracy of predicting GEBV for residual feed intake (RFI) based on 522 Angus and 395 Charolais steers genotyped on SNP with the Illumina Bovine SNP50 Beadchip for 3 training population forming strategies: within breed, across breed, and by pooling data from the 2 breeds (i.e., combined). Two other scenarios with the training and validation data split by birth year and by sire family within a breed were also investigated to assess the impact of genetic relationships on the accuracy of genomic prediction. Three statistical methods including the best linear unbiased prediction with the relationship matrix defined based on the pedigree (PBLUP), based on the SNP genotypes (GBLUP), and a Bayesian method (BayesB) were used to predict the GEBV. The results showed that the accuracy of the GEBV prediction was the highest when the prediction was within breed and when the validation population had greater genetic relationships with the training population, with a maximum of 0.58 for Angus and 0.64 for Charolais. The within-breed prediction accuracies dropped to 0.29 and 0.38, respectively, when the validation populations had a minimal pedigree link with the training population. When the training population of a different breed was used to predict the GEBV of the validation population, that is, across-breed genomic prediction, the accuracies were further reduced to 0.10 to 0.22, depending on the prediction method used. Pooling data from the 2 breeds to form the training population resulted in accuracies increased

  2. Accuracy and speed feedback: Global and local effects on strategy use

    PubMed Central

    Touron, Dayna R.; Hertzog, Christopher

    2013-01-01

    Background Skill acquisition often involves a shift from an effortful algorithm-based strategy to more fluent memory-based performance. Older adults’ slower strategy transitions can be ascribed to both slowed learning and metacognitive factors. Experimenters often provide feedback on response accuracy; this emphasis may either inadvertently reinforce older adults’ conservatism or might highlight that retrieval is generally quite accurate. RT feedback can lead to more rapid shift to retrieval (Hertzog, Touron, & Hines, 2007). Methods This study parametrically varied trial-by-trial feedback to examine whether strategy shifts in the noun-pair task in younger (M = 19) and older adults (M = 67) were influenced by type of performance feedback: none, trial accuracy, trial RT, or both accuracy and RT. Results Older adults who received accuracy feedback retrieved more often, particularly on difficult rearranged trials, and participants who receive speed feedback performed the scanning strategy more quickly. Age differences were also obtained in local (trial-level) reactivity to task performance, but these were not affected by feedback. Conclusions Accuracy and speed feedback had distinct global (general) influences on task strategies and performance. In particular, it appears that the standard practice of providing trial-by-trial accuracy feedback might facilitate older adults’ use of retrieval strategies in skill acquisition tasks. PMID:24785594

  3. Location Accuracy of INS/Gravity-Integrated Navigation System on the Basis of Ocean Experiment and Simulation

    PubMed Central

    Wang, Hubiao; Chai, Hua; Bao, Lifeng; Wang, Yong

    2017-01-01

    An experiment comparing the location accuracy of gravity matching-aided navigation in the ocean and simulation is very important to evaluate the feasibility and the performance of an INS/gravity-integrated navigation system (IGNS) in underwater navigation. Based on a 1′ × 1′ marine gravity anomaly reference map and multi-model adaptive Kalman filtering algorithm, a matching location experiment of IGNS was conducted using data obtained using marine gravimeter. The location accuracy under actual ocean conditions was 2.83 nautical miles (n miles). Several groups of simulated data of marine gravity anomalies were obtained by establishing normally distributed random error N(u,σ2) with varying mean u and noise variance σ2. Thereafter, the matching location of IGNS was simulated. The results show that the changes in u had little effect on the location accuracy. However, an increase in σ2 resulted in a significant decrease in the location accuracy. A comparison between the actual ocean experiment and the simulation along the same route demonstrated the effectiveness of the proposed simulation method and quantitative analysis results. In addition, given the gravimeter (1–2 mGal accuracy) and the reference map (resolution 1′ × 1′; accuracy 3–8 mGal), location accuracy of IGNS was up to reach ~1.0–3.0 n miles in the South China Sea. PMID:29261136

  4. Location Accuracy of INS/Gravity-Integrated Navigation System on the Basis of Ocean Experiment and Simulation.

    PubMed

    Wang, Hubiao; Wu, Lin; Chai, Hua; Bao, Lifeng; Wang, Yong

    2017-12-20

    An experiment comparing the location accuracy of gravity matching-aided navigation in the ocean and simulation is very important to evaluate the feasibility and the performance of an INS/gravity-integrated navigation system (IGNS) in underwater navigation. Based on a 1' × 1' marine gravity anomaly reference map and multi-model adaptive Kalman filtering algorithm, a matching location experiment of IGNS was conducted using data obtained using marine gravimeter. The location accuracy under actual ocean conditions was 2.83 nautical miles (n miles). Several groups of simulated data of marine gravity anomalies were obtained by establishing normally distributed random error N ( u , σ 2 ) with varying mean u and noise variance σ 2 . Thereafter, the matching location of IGNS was simulated. The results show that the changes in u had little effect on the location accuracy. However, an increase in σ 2 resulted in a significant decrease in the location accuracy. A comparison between the actual ocean experiment and the simulation along the same route demonstrated the effectiveness of the proposed simulation method and quantitative analysis results. In addition, given the gravimeter (1-2 mGal accuracy) and the reference map (resolution 1' × 1'; accuracy 3-8 mGal), location accuracy of IGNS was up to reach ~1.0-3.0 n miles in the South China Sea.

  5. Effects of lek count protocols on greater sage-grouse population trend estimates

    USGS Publications Warehouse

    Monroe, Adrian; Edmunds, David; Aldridge, Cameron L.

    2016-01-01

    Annual counts of males displaying at lek sites are an important tool for monitoring greater sage-grouse populations (Centrocercus urophasianus), but seasonal and diurnal variation in lek attendance may increase variance and bias of trend analyses. Recommendations for protocols to reduce observation error have called for restricting lek counts to within 30 minutes of sunrise, but this may limit the number of lek counts available for analysis, particularly from years before monitoring was widely standardized. Reducing the temporal window for conducting lek counts also may constrain the ability of agencies to monitor leks efficiently. We used lek count data collected across Wyoming during 1995−2014 to investigate the effect of lek counts conducted between 30 minutes before and 30, 60, or 90 minutes after sunrise on population trend estimates. We also evaluated trends across scales relevant to management, including statewide, within Working Group Areas and Core Areas, and for individual leks. To further evaluate accuracy and precision of trend estimates from lek count protocols, we used simulations based on a lek attendance model and compared simulated and estimated values of annual rate of change in population size (λ) from scenarios of varying numbers of leks, lek count timing, and count frequency (counts/lek/year). We found that restricting analyses to counts conducted within 30 minutes of sunrise generally did not improve precision of population trend estimates, although differences among timings increased as the number of leks and count frequency decreased. Lek attendance declined >30 minutes after sunrise, but simulations indicated that including lek counts conducted up to 90 minutes after sunrise can increase the number of leks monitored compared to trend estimates based on counts conducted within 30 minutes of sunrise. This increase in leks monitored resulted in greater precision of estimates without reducing accuracy. Increasing count

  6. Experimental studies of high-accuracy RFID localization with channel impairments

    NASA Astrophysics Data System (ADS)

    Pauls, Eric; Zhang, Yimin D.

    2015-05-01

    Radio frequency identification (RFID) systems present an incredibly cost-effective and easy-to-implement solution to close-range localization. One of the important applications of a passive RFID system is to determine the reader position through multilateration based on the estimated distances between the reader and multiple distributed reference tags obtained from, e.g., the received signal strength indicator (RSSI) readings. In practice, the achievable accuracy of passive RFID reader localization suffers from many factors, such as the distorted RSSI reading due to channel impairments in terms of the susceptibility to reader antenna patterns and multipath propagation. Previous studies have shown that the accuracy of passive RFID localization can be significantly improved by properly modeling and compensating for such channel impairments. The objective of this paper is to report experimental study results that validate the effectiveness of such approaches for high-accuracy RFID localization. We also examine a number of practical issues arising in the underlying problem that limit the accuracy of reader-tag distance measurements and, therefore, the estimated reader localization. These issues include the variations in tag radiation characteristics for similar tags, effects of tag orientations, and reader RSS quantization and measurement errors. As such, this paper reveals valuable insights of the issues and solutions toward achieving high-accuracy passive RFID localization.

  7. Generation of a high-accuracy regional DEM based on ALOS/PRISM imagery of East Antarctica

    NASA Astrophysics Data System (ADS)

    Shiramizu, Kaoru; Doi, Koichiro; Aoyama, Yuichi

    2017-12-01

    A digital elevation model (DEM) is used to estimate ice-flow velocities for an ice sheet and glaciers via Differential Interferometric Synthetic Aperture Radar (DInSAR) processing. The accuracy of DInSAR-derived displacement estimates depends upon the accuracy of the DEM. Therefore, we used stereo optical images, obtained with a panchromatic remote-sensing instrument for stereo mapping (PRISM) sensor mounted onboard the Advanced Land Observing Satellite (ALOS), to produce a new DEM ("PRISM-DEM") of part of the coastal region of Lützow-Holm Bay in Dronning Maud Land, East Antarctica. We verified the accuracy of the PRISM-DEM by comparing ellipsoidal heights with those of existing DEMs and values obtained by satellite laser altimetry (ICESat/GLAS) and Global Navigation Satellite System surveying. The accuracy of the PRISM-DEM is estimated to be 2.80 m over ice sheet, 4.86 m over individual glaciers, and 6.63 m over rock outcrops. By comparison, the estimated accuracy of the ASTER-GDEM, widely used in polar regions, is 33.45 m over ice sheet, 14.61 m over glaciers, and 19.95 m over rock outcrops. For displacement measurements made along the radar line-of-sight by DInSAR, in conjunction with ALOS/PALSAR data, the accuracy of the PRISM-DEM and ASTER-GDEM correspond to estimation errors of <6.3 mm and <31.8 mm, respectively.

  8. Improving the Accuracy of Structural Fatigue Life Tracking Through Dynamic Strain Sensor Calibration

    DTIC Science & Technology

    2011-09-01

    strength corrosion resistant 7075 -T6 alloy, and included hinge lugs, a bulkhead, spars, and wing skins that were fastened together using welds, rivets...release, distribution unlimited 13. SUPPLEMENTARY NOTES See also ADA580921. International Workshop on Structural Health Monitoring: From Condition -based...greater than 10% under the same loading conditions [1]. These differences must be accounted for to have acceptable accuracy levels in the ultimate

  9. Recognition memory and awareness: A high-frequency advantage in the accuracy of knowing.

    PubMed

    Gregg, Vernon H; Gardiner, John M; Karayianni, Irene; Konstantinou, Ira

    2006-04-01

    The well-established advantage of low-frequency words over high-frequency words in recognition memory has been found to occur in remembering and not knowing. Two experiments employed remember and know judgements, and divided attention to investigate the possibility of an effect of word frequency on know responses given appropriate study conditions. With undivided attention at study, the usual low-frequency advantage in the accuracy of remember responses, but no effect on know responses, was obtained. Under a demanding divided attention task at encoding, a high-frequency advantage in the accuracy of know responses was obtained. The results are discussed in relation to theories of knowing, particularly those incorporating perceptual and conceptual fluency.

  10. Quantifying the Validity of Routine Neonatal Healthcare Data in the Greater Accra Region, Ghana

    PubMed Central

    Kayode, Gbenga A.; Amoakoh-Coleman, Mary; Brown-Davies, Charles; Grobbee, Diederick E.; Agyepong, Irene Akua; Ansah, Evelyn; Klipstein-Grobusch, Kerstin

    2014-01-01

    Objectives The District Health Information Management System–2 (DHIMS–2) is the database for storing health service data in Ghana, and similar to other low and middle income countries, paper-based data collection is being used by the Ghana Health Service. As the DHIMS-2 database has not been validated before this study aimed to evaluate its validity. Methods Seven out of ten districts in the Greater Accra Region were randomly sampled; the district hospital and a polyclinic in each district were recruited for validation. Seven pre-specified neonatal health indicators were considered for validation: antenatal registrants, deliveries, total births, live birth, stillbirth, low birthweight, and neonatal death. Data were extracted on these health indicators from the primary data (hospital paper-registers) recorded from January to March 2012. We examined all the data captured during this period as these data have been uploaded to the DHIMS-2 database. The differences between the values of the health indicators obtained from the primary data and that of the facility and DHIMS–2 database were used to assess the accuracy of the database while its completeness was estimated by the percentage of missing data in the primary data. Results About 41,000 data were assessed and in almost all the districts, the error rates of the DHIMS-2 data were less than 2.1% while the percentages of missing data were below 2%. At the regional level, almost all the health indicators had an error rate below 1% while the overall error rate of the DHIMS-2 database was 0.68% (95% C I = 0.61–0.75) and the percentage of missing data was 3.1% (95% C I = 2.96–3.24). Conclusion This study demonstrated that the percentage of missing data in the DHIMS-2 database was negligible while its accuracy was close to the acceptable range for high quality data. PMID:25144222

  11. Bias in estimating accuracy of a binary screening test with differential disease verification

    PubMed Central

    Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.

    2011-01-01

    SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059

  12. Prospective memory mediated by interoceptive accuracy: a psychophysiological approach.

    PubMed

    Umeda, Satoshi; Tochizawa, Saiko; Shibata, Midori; Terasawa, Yuri

    2016-11-19

    Previous studies on prospective memory (PM), defined as memory for future intentions, suggest that psychological stress enhances successful PM retrieval. However, the mechanisms underlying this notion remain poorly understood. We hypothesized that PM retrieval is achieved through interaction with autonomic nervous activity, which is mediated by the individual accuracy of interoceptive awareness, as measured by the heartbeat detection task. In this study, the relationship between cardiac reactivity and retrieval of delayed intentions was evaluated using the event-based PM task. Participants were required to detect PM target letters while engaged in an ongoing 2-back working memory task. The results demonstrated that individuals with higher PM task performance had a greater increase in heart rate on PM target presentation. Also, higher interoceptive perceivers showed better PM task performance. This pattern was not observed for working memory task performance. These findings suggest that cardiac afferent signals enhance PM retrieval, which is mediated by individual levels of interoceptive accuracy.This article is part of the themed issue 'Interoception beyond homeostasis: affect, cognition and mental health'. © 2016 The Authors.

  13. Accuracy of estimation of genomic breeding values in pigs using low-density genotypes and imputation.

    PubMed

    Badke, Yvonne M; Bates, Ronald O; Ernst, Catherine W; Fix, Justin; Steibel, Juan P

    2014-04-16

    Genomic selection has the potential to increase genetic progress. Genotype imputation of high-density single-nucleotide polymorphism (SNP) genotypes can improve the cost efficiency of genomic breeding value (GEBV) prediction for pig breeding. Consequently, the objectives of this work were to: (1) estimate accuracy of genomic evaluation and GEBV for three traits in a Yorkshire population and (2) quantify the loss of accuracy of genomic evaluation and GEBV when genotypes were imputed under two scenarios: a high-cost, high-accuracy scenario in which only selection candidates were imputed from a low-density platform and a low-cost, low-accuracy scenario in which all animals were imputed using a small reference panel of haplotypes. Phenotypes and genotypes obtained with the PorcineSNP60 BeadChip were available for 983 Yorkshire boars. Genotypes of selection candidates were masked and imputed using tagSNP in the GeneSeek Genomic Profiler (10K). Imputation was performed with BEAGLE using 128 or 1800 haplotypes as reference panels. GEBV were obtained through an animal-centric ridge regression model using de-regressed breeding values as response variables. Accuracy of genomic evaluation was estimated as the correlation between estimated breeding values and GEBV in a 10-fold cross validation design. Accuracy of genomic evaluation using observed genotypes was high for all traits (0.65-0.68). Using genotypes imputed from a large reference panel (accuracy: R(2) = 0.95) for genomic evaluation did not significantly decrease accuracy, whereas a scenario with genotypes imputed from a small reference panel (R(2) = 0.88) did show a significant decrease in accuracy. Genomic evaluation based on imputed genotypes in selection candidates can be implemented at a fraction of the cost of a genomic evaluation using observed genotypes and still yield virtually the same accuracy. On the other side, using a very small reference panel of haplotypes to impute training animals and candidates for

  14. Influence of Pedometer Position on Pedometer Accuracy at Various Walking Speeds: A Comparative Study

    PubMed Central

    Lovis, Christian

    2016-01-01

    Background Demographic growth in conjunction with the rise of chronic diseases is increasing the pressure on health care systems in most OECD countries. Physical activity is known to be an essential factor in improving or maintaining good health. Walking is especially recommended, as it is an activity that can easily be performed by most people without constraints. Pedometers have been extensively used as an incentive to motivate people to become more active. However, a recognized problem with these devices is their diminishing accuracy associated with decreased walking speed. The arrival on the consumer market of new devices, worn indifferently either at the waist, wrist, or as a necklace, gives rise to new questions regarding their accuracy at these different positions. Objective Our objective was to assess the performance of 4 pedometers (iHealth activity monitor, Withings Pulse O2, Misfit Shine, and Garmin vívofit) and compare their accuracy according to their position worn, and at various walking speeds. Methods We conducted this study in a controlled environment with 21 healthy adults required to walk 100 m at 3 different paces (0.4 m/s, 0.6 m/s, and 0.8 m/s) regulated by means of a string attached between their legs at the level of their ankles and a metronome ticking the cadence. To obtain baseline values, we asked the participants to walk 200 m at their own pace. Results A decrease of accuracy was positively correlated with reduced speed for all pedometers (12% mean error at self-selected pace, 27% mean error at 0.8 m/s, 52% mean error at 0.6 m/s, and 76% mean error at 0.4 m/s). Although the position of the pedometer on the person did not significantly influence its accuracy, some interesting tendencies can be highlighted in 2 settings: (1) positioning the pedometer at the waist at a speed greater than 0.8 m/s or as a necklace at preferred speed tended to produce lower mean errors than at the wrist position; and (2) at a slow speed (0.4 m/s), pedometers

  15. High accuracy electronic material level sensor

    DOEpatents

    McEwan, T.E.

    1997-03-11

    The High Accuracy Electronic Material Level Sensor (electronic dipstick) is a sensor based on time domain reflectometry (TDR) of very short electrical pulses. Pulses are propagated along a transmission line or guide wire that is partially immersed in the material being measured; a launcher plate is positioned at the beginning of the guide wire. Reflected pulses are produced at the material interface due to the change in dielectric constant. The time difference of the reflections at the launcher plate and at the material interface are used to determine the material level. Improved performance is obtained by the incorporation of: (1) a high accuracy time base that is referenced to a quartz crystal, (2) an ultrawideband directional sampler to allow operation without an interconnect cable between the electronics module and the guide wire, (3) constant fraction discriminators (CFDs) that allow accurate measurements regardless of material dielectric constants, and reduce or eliminate errors induced by triple-transit or ``ghost`` reflections on the interconnect cable. These improvements make the dipstick accurate to better than 0.1%. 4 figs.

  16. High accuracy electronic material level sensor

    DOEpatents

    McEwan, Thomas E.

    1997-01-01

    The High Accuracy Electronic Material Level Sensor (electronic dipstick) is a sensor based on time domain reflectometry (TDR) of very short electrical pulses. Pulses are propagated along a transmission line or guide wire that is partially immersed in the material being measured; a launcher plate is positioned at the beginning of the guide wire. Reflected pulses are produced at the material interface due to the change in dielectric constant. The time difference of the reflections at the launcher plate and at the material interface are used to determine the material level. Improved performance is obtained by the incorporation of: 1) a high accuracy time base that is referenced to a quartz crystal, 2) an ultrawideband directional sampler to allow operation without an interconnect cable between the electronics module and the guide wire, 3) constant fraction discriminators (CFDs) that allow accurate measurements regardless of material dielectric constants, and reduce or eliminate errors induced by triple-transit or "ghost" reflections on the interconnect cable. These improvements make the dipstick accurate to better than 0.1%.

  17. Accuracy of 3 different impression techniques for internal connection angulated implants.

    PubMed

    Tsagkalidis, George; Tortopidis, Dimitrios; Mpikos, Pavlos; Kaisarlis, George; Koidis, Petros

    2015-10-01

    Making implant impressions with different angulations requires a more precise and time-consuming impression technique. The purpose of this in vitro study was to compare the accuracy of nonsplinted, splinted, and snap-fit impression techniques of internal connection implants with different angulations. An experimental device was used to allow a clinical simulation of impression making by means of open and closed tray techniques. Three different impression techniques (nonsplinted, acrylic-resin splinted, and indirect snap-fit) for 6 internal-connected implants at different angulations (0, 15, 25 degrees) were examined using polyether. Impression accuracy was evaluated by measuring the differences in 3-dimensional (3D) position deviations between the implant body/impression coping before the impression procedure and the coping/laboratory analog positioned within the impression, using a coordinate measuring machine. Data were analyzed by 2-way ANOVA. Means were compared with the least significant difference criterion at P<.05. Results showed that at 25 degrees of implant angulation, the highest accuracy was obtained with the splinted technique (mean ±SE: 0.39 ±0.05 mm) and the lowest with the snap-fit technique (0.85 ±0.09 mm); at 15 degrees of angulation, there were no significant differences among splinted (0.22 ±0.04 mm) and nonsplinted technique (0.15 ±0.02 mm) and the lowest accuracy obtained with the snap-fit technique (0.95 ±0.15 mm); and no significant differences were found between nonsplinted and splinted technique at 0 degrees of implant placement. Splinted impression technique exhibited a higher accuracy than the other techniques studied when increased implant angulations at 25 degrees were involved. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Prediction accuracies for growth and wood attributes of interior spruce in space using genotyping-by-sequencing.

    PubMed

    Gamal El-Dien, Omnia; Ratcliffe, Blaise; Klápště, Jaroslav; Chen, Charles; Porth, Ilga; El-Kassaby, Yousry A

    2015-05-09

    Genomic selection (GS) in forestry can substantially reduce the length of breeding cycle and increase gain per unit time through early selection and greater selection intensity, particularly for traits of low heritability and late expression. Affordable next-generation sequencing technologies made it possible to genotype large numbers of trees at a reasonable cost. Genotyping-by-sequencing was used to genotype 1,126 Interior spruce trees representing 25 open-pollinated families planted over three sites in British Columbia, Canada. Four imputation algorithms were compared (mean value (MI), singular value decomposition (SVD), expectation maximization (EM), and a newly derived, family-based k-nearest neighbor (kNN-Fam)). Trees were phenotyped for several yield and wood attributes. Single- and multi-site GS prediction models were developed using the Ridge Regression Best Linear Unbiased Predictor (RR-BLUP) and the Generalized Ridge Regression (GRR) to test different assumption about trait architecture. Finally, using PCA, multi-trait GS prediction models were developed. The EM and kNN-Fam imputation methods were superior for 30 and 60% missing data, respectively. The RR-BLUP GS prediction model produced better accuracies than the GRR indicating that the genetic architecture for these traits is complex. GS prediction accuracies for multi-site were high and better than those of single-sites while multi-site predictability produced the lowest accuracies reflecting type-b genetic correlations and deemed unreliable. The incorporation of genomic information in quantitative genetics analyses produced more realistic heritability estimates as half-sib pedigree tended to inflate the additive genetic variance and subsequently both heritability and gain estimates. Principle component scores as representatives of multi-trait GS prediction models produced surprising results where negatively correlated traits could be concurrently selected for using PCA2 and PCA3. The application of

  19. The Accuracy of GBM GRB Localizations

    NASA Astrophysics Data System (ADS)

    Briggs, Michael Stephen; Connaughton, V.; Meegan, C.; Hurley, K.

    2010-03-01

    We report an study of the accuracy of GBM GRB localizations, analyzing three types of localizations: those produced automatically by the GBM Flight Software on board GBM, those produced automatically with ground software in near real time, and localizations produced with human guidance. The two types of automatic locations are distributed in near real-time via GCN Notices; the human-guided locations are distributed on timescale of many minutes or hours using GCN Circulars. This work uses a Bayesian analysis that models the distribution of the GBM total location error by comparing GBM locations to more accurate locations obtained with other instruments. Reference locations are obtained from Swift, Super-AGILE, the LAT, and with the IPN. We model the GBM total location errors as having systematic errors in addition to the statistical errors and use the Bayesian analysis to constrain the systematic errors.

  20. Analysis of short pulse laser altimetry data obtained over horizontal path

    NASA Technical Reports Server (NTRS)

    Im, K. E.; Tsai, B. M.; Gardner, C. S.

    1983-01-01

    Recent pulsed measurements of atmospheric delay obtained by ranging to the more realistic targets including a simulated ocean target and an extended plate target are discussed. These measurements are used to estimate the expected timing accuracy of a correlation receiver system. The experimental work was conducted using a pulsed two color laser altimeter.

  1. Overlay accuracy fundamentals

    NASA Astrophysics Data System (ADS)

    Kandel, Daniel; Levinski, Vladimir; Sapiens, Noam; Cohen, Guy; Amit, Eran; Klein, Dana; Vakshtein, Irina

    2012-03-01

    Currently, the performance of overlay metrology is evaluated mainly based on random error contributions such as precision and TIS variability. With the expected shrinkage of the overlay metrology budget to < 0.5nm, it becomes crucial to include also systematic error contributions which affect the accuracy of the metrology. Here we discuss fundamental aspects of overlay accuracy and a methodology to improve accuracy significantly. We identify overlay mark imperfections and their interaction with the metrology technology, as the main source of overlay inaccuracy. The most important type of mark imperfection is mark asymmetry. Overlay mark asymmetry leads to a geometrical ambiguity in the definition of overlay, which can be ~1nm or less. It is shown theoretically and in simulations that the metrology may enhance the effect of overlay mark asymmetry significantly and lead to metrology inaccuracy ~10nm, much larger than the geometrical ambiguity. The analysis is carried out for two different overlay metrology technologies: Imaging overlay and DBO (1st order diffraction based overlay). It is demonstrated that the sensitivity of DBO to overlay mark asymmetry is larger than the sensitivity of imaging overlay. Finally, we show that a recently developed measurement quality metric serves as a valuable tool for improving overlay metrology accuracy. Simulation results demonstrate that the accuracy of imaging overlay can be improved significantly by recipe setup optimized using the quality metric. We conclude that imaging overlay metrology, complemented by appropriate use of measurement quality metric, results in optimal overlay accuracy.

  2. Hydrides of intermetallic compounds with a H/M ratio greater than unity obtained at high hydrogen pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Semenenko, K.N.; Klyamkin, S.N.

    1993-11-01

    Novel hydride phases with H/M > 1 based on Zr{sub 2}Pd, Hf{sub 2}Pd, and Hf{sub 2}Cu (structures of the MoSi{sub 2} type) have been synthesized at high H{sub 2} pressures. The X-ray diffraction investigations of the resulting hydrides have been carried out. Some factors determining the maximum hydrogen content in the hydrides of intermetallic compounds are discussed. A model structure of the hydrides obtained is proposed, which assumes the possibility of direct H-H interactions when the interatomic distances are less than 1 {angstrom}.

  3. Accuracy Analysis of a Dam Model from Drone Surveys

    PubMed Central

    Buffi, Giulia; Venturi, Sara

    2017-01-01

    This paper investigates the accuracy of models obtained by drone surveys. To this end, this work analyzes how the placement of ground control points (GCPs) used to georeference the dense point cloud of a dam affects the resulting three-dimensional (3D) model. Images of a double arch masonry dam upstream face are acquired from drone survey and used to build the 3D model of the dam for vulnerability analysis purposes. However, there still remained the issue of understanding the real impact of a correct GCPs location choice to properly georeference the images and thus, the model. To this end, a high number of GCPs configurations were investigated, building a series of dense point clouds. The accuracy of these resulting dense clouds was estimated comparing the coordinates of check points extracted from the model and their true coordinates measured via traditional topography. The paper aims at providing information about the optimal choice of GCPs placement not only for dams but also for all surveys of high-rise structures. The knowledge a priori of the effect of the GCPs number and location on the model accuracy can increase survey reliability and accuracy and speed up the survey set-up operations. PMID:28771185

  4. Accuracy Analysis of a Dam Model from Drone Surveys.

    PubMed

    Ridolfi, Elena; Buffi, Giulia; Venturi, Sara; Manciola, Piergiorgio

    2017-08-03

    This paper investigates the accuracy of models obtained by drone surveys. To this end, this work analyzes how the placement of ground control points (GCPs) used to georeference the dense point cloud of a dam affects the resulting three-dimensional (3D) model. Images of a double arch masonry dam upstream face are acquired from drone survey and used to build the 3D model of the dam for vulnerability analysis purposes. However, there still remained the issue of understanding the real impact of a correct GCPs location choice to properly georeference the images and thus, the model. To this end, a high number of GCPs configurations were investigated, building a series of dense point clouds. The accuracy of these resulting dense clouds was estimated comparing the coordinates of check points extracted from the model and their true coordinates measured via traditional topography. The paper aims at providing information about the optimal choice of GCPs placement not only for dams but also for all surveys of high-rise structures. The knowledge a priori of the effect of the GCPs number and location on the model accuracy can increase survey reliability and accuracy and speed up the survey set-up operations.

  5. Improve accuracy for automatic acetabulum segmentation in CT images.

    PubMed

    Liu, Hao; Zhao, Jianning; Dai, Ning; Qian, Hongbo; Tang, Yuehong

    2014-01-01

    Separation of the femur head and acetabulum is one of main difficulties in the diseased hip joint due to deformed shapes and extreme narrowness of the joint space. To improve the segmentation accuracy is the key point of existing automatic or semi-automatic segmentation methods. In this paper, we propose a new method to improve the accuracy of the segmented acetabulum using surface fitting techniques, which essentially consists of three parts: (1) design a surface iterative process to obtain an optimization surface; (2) change the ellipsoid fitting to two-phase quadric surface fitting; (3) bring in a normal matching method and an optimization region method to capture edge points for the fitting quadric surface. Furthermore, this paper cited vivo CT data sets of 40 actual patients (with 79 hip joints). Test results for these clinical cases show that: (1) the average error of the quadric surface fitting method is 2.3 (mm); (2) the accuracy ratio of automatically recognized contours is larger than 89.4%; (3) the error ratio of section contours is less than 10% for acetabulums without severe malformation and less than 30% for acetabulums with severe malformation. Compared with similar methods, the accuracy of our method, which is applied in a software system, is significantly enhanced.

  6. An evaluation of information retrieval accuracy with simulated OCR output

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Croft, W.B.; Harding, S.M.; Taghva, K.

    Optical Character Recognition (OCR) is a critical part of many text-based applications. Although some commercial systems use the output from OCR devices to index documents without editing, there is very little quantitative data on the impact of OCR errors on the accuracy of a text retrieval system. Because of the difficulty of constructing test collections to obtain this data, we have carried out evaluation using simulated OCR output on a variety of databases. The results show that high quality OCR devices have little effect on the accuracy of retrieval, but low quality devices used with databases of short documents canmore » result in significant degradation.« less

  7. High-accuracy direct aerial platform orientation with tightly coupled GPS/INS system.

    DOT National Transportation Integrated Search

    2004-09-01

    Obtaining sensor orientation by direct measurements is a rapidly emerging mapping technology. Modern GPS and INS systems allow for the direct determination of platform position and orientation at an unprecedented accuracy. In airborne surveying, airc...

  8. On the accuracy of instantaneous gas exchange rates, energy expenditure and respiratory quotient calculations obtained from indirect whole room calorimetry.

    PubMed

    Gribok, Andrei; Hoyt, Reed; Buller, Mark; Rumpler, William

    2013-06-01

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause-effect relationship where the gaseous exchange rates representing the unknown causes need to be inferred from a known, noisy effect-gaseous concentrations. Two methods of such inference are analyzed. The first method is based on the previously published regularized deconvolution of the molar balance equation and the second one, proposed in this paper, relies on regularized differentiation of gaseous concentrations. It is found that both methods produce similar results for the absolute values of metabolic variables and their accuracy. The uncertainty for O2 consumption rate is found to be 7% and for CO2 production--3.2%. The uncertainties in gaseous exchange rates do not depend on the absolute values of O2 consumption and CO2 production. In contrast, the absolute uncertainty in respiratory quotient is a function of the gaseous exchange rates and varies from 9.4% during the night to 2.3% during moderate exercise. The uncertainty in energy expenditure was found to be 5.9% and independent of the level of gaseous exchange. For both methods, closed form analytical formulas for confidence intervals are provided allowing quantification of uncertainty for four major metabolic variables in real world studies.

  9. Accuracy improvement of multimodal measurement of speed of sound based on image processing

    NASA Astrophysics Data System (ADS)

    Nitta, Naotaka; Kaya, Akio; Misawa, Masaki; Hyodo, Koji; Numano, Tomokazu

    2017-07-01

    Since the speed of sound (SOS) reflects tissue characteristics and is expected as an evaluation index of elasticity and water content, the noninvasive measurement of SOS is eagerly anticipated. However, it is difficult to measure the SOS by using an ultrasound device alone. Therefore, we have presented a noninvasive measurement method of SOS using ultrasound (US) and magnetic resonance (MR) images. By this method, we determine the longitudinal SOS based on the thickness measurement using the MR image and the time of flight (TOF) measurement using the US image. The accuracy of SOS measurement is affected by the accuracy of image registration and the accuracy of thickness measurements in the MR and US images. In this study, we address the accuracy improvement in the latter thickness measurement, and present an image-processing-based method for improving the accuracy of thickness measurement. The method was investigated by using in vivo data obtained from a tissue-engineered cartilage implanted in the back of a rat, with an unclear boundary.

  10. Accuracies of breeding values for dry matter intake using nongenotyped animals and predictor traits in different lactations.

    PubMed

    Manzanilla-Pech, C I V; Veerkamp, R F; de Haas, Y; Calus, M P L; Ten Napel, J

    2017-11-01

    Given the interest of including dry matter intake (DMI) in the breeding goal, accurate estimated breeding values (EBV) for DMI are needed, preferably for separate lactations. Due to the limited amount of records available on DMI, 2 main approaches have been suggested to compute those EBV: (1) the inclusion of predictor traits, such as fat- and protein-corrected milk (FPCM) and live weight (LW), and (2) the addition of genomic information of animals using what is called genomic prediction. Recently, several methodologies to estimate EBV utilizing genomic information (EBV) have become available. In this study, a new method known as single-step ridge-regression BLUP (SSRR-BLUP) is suggested. The SSRR-BLUP method does not have an imposed limit on the number of genotyped animals, as the commonly used methods do. The objective of this study was to estimate genetic parameters using a relatively large data set with DMI records, as well as compare the accuracies of the EBV for DMI. These accuracies were obtained using 4 different methods: BLUP (using pedigree for all animals with phenotypes), genomic BLUP (GBLUP; only for genotyped animals), single-step GBLUP (SS-GBLUP), and SSRR-BLUP (for genotyped and nongenotyped animals). Records from different lactations, with or without predictor traits (FPCM and LW), were used in the model. Accuracies of EBV for DMI (defined as the correlation between the EBV and pre-adjusted DMI phenotypes divided by the average accuracy of those phenotypes) ranged between 0.21 and 0.38 across methods and scenarios. Accuracies of EBV for DMI using BLUP were the lowest accuracies obtained across methods. Meanwhile, accuracies of EBV for DMI were similar in SS-GBLUP and SSRR-BLUP, and lower for the GBLUP method. Hence, SSRR-BLUP could be used when the number of genotyped animals is large, avoiding the construction of the inverse genomic relationship matrix. Adding information on DMI from different lactations in the reference population gave higher

  11. Positional Accuracy Assessment of Googleearth in Riyadh

    NASA Astrophysics Data System (ADS)

    Farah, Ashraf; Algarni, Dafer

    2014-06-01

    Google Earth is a virtual globe, map and geographical information program that is controlled by Google corporation. It maps the Earth by the superimposition of images obtained from satellite imagery, aerial photography and GIS 3D globe. With millions of users all around the globe, GoogleEarth® has become the ultimate source of spatial data and information for private and public decision-support systems besides many types and forms of social interactions. Many users mostly in developing countries are also using it for surveying applications, the matter that raises questions about the positional accuracy of the Google Earth program. This research presents a small-scale assessment study of the positional accuracy of GoogleEarth® Imagery in Riyadh; capital of Kingdom of Saudi Arabia (KSA). The results show that the RMSE of the GoogleEarth imagery is 2.18 m and 1.51 m for the horizontal and height coordinates respectively.

  12. Influence of pansharpening techniques in obtaining accurate vegetation thematic maps

    NASA Astrophysics Data System (ADS)

    Ibarrola-Ulzurrun, Edurne; Gonzalo-Martin, Consuelo; Marcello-Ruiz, Javier

    2016-10-01

    In last decades, there have been a decline in natural resources, becoming important to develop reliable methodologies for their management. The appearance of very high resolution sensors has offered a practical and cost-effective means for a good environmental management. In this context, improvements are needed for obtaining higher quality of the information available in order to get reliable classified images. Thus, pansharpening enhances the spatial resolution of the multispectral band by incorporating information from the panchromatic image. The main goal in the study is to implement pixel and object-based classification techniques applied to the fused imagery using different pansharpening algorithms and the evaluation of thematic maps generated that serve to obtain accurate information for the conservation of natural resources. A vulnerable heterogenic ecosystem from Canary Islands (Spain) was chosen, Teide National Park, and Worldview-2 high resolution imagery was employed. The classes considered of interest were set by the National Park conservation managers. 7 pansharpening techniques (GS, FIHS, HCS, MTF based, Wavelet `à trous' and Weighted Wavelet `à trous' through Fractal Dimension Maps) were chosen in order to improve the data quality with the goal to analyze the vegetation classes. Next, different classification algorithms were applied at pixel-based and object-based approach, moreover, an accuracy assessment of the different thematic maps obtained were performed. The highest classification accuracy was obtained applying Support Vector Machine classifier at object-based approach in the Weighted Wavelet `à trous' through Fractal Dimension Maps fused image. Finally, highlight the difficulty of the classification in Teide ecosystem due to the heterogeneity and the small size of the species. Thus, it is important to obtain accurate thematic maps for further studies in the management and conservation of natural resources.

  13. Accuracy analysis and design of A3 parallel spindle head

    NASA Astrophysics Data System (ADS)

    Ni, Yanbing; Zhang, Biao; Sun, Yupeng; Zhang, Yuan

    2016-03-01

    As functional components of machine tools, parallel mechanisms are widely used in high efficiency machining of aviation components, and accuracy is one of the critical technical indexes. Lots of researchers have focused on the accuracy problem of parallel mechanisms, but in terms of controlling the errors and improving the accuracy in the stage of design and manufacturing, further efforts are required. Aiming at the accuracy design of a 3-DOF parallel spindle head(A3 head), its error model, sensitivity analysis and tolerance allocation are investigated. Based on the inverse kinematic analysis, the error model of A3 head is established by using the first-order perturbation theory and vector chain method. According to the mapping property of motion and constraint Jacobian matrix, the compensatable and uncompensatable error sources which affect the accuracy in the end-effector are separated. Furthermore, sensitivity analysis is performed on the uncompensatable error sources. The sensitivity probabilistic model is established and the global sensitivity index is proposed to analyze the influence of the uncompensatable error sources on the accuracy in the end-effector of the mechanism. The results show that orientation error sources have bigger effect on the accuracy in the end-effector. Based upon the sensitivity analysis results, the tolerance design is converted into the issue of nonlinearly constrained optimization with the manufacturing cost minimum being the optimization objective. By utilizing the genetic algorithm, the allocation of the tolerances on each component is finally determined. According to the tolerance allocation results, the tolerance ranges of ten kinds of geometric error sources are obtained. These research achievements can provide fundamental guidelines for component manufacturing and assembly of this kind of parallel mechanisms.

  14. Accuracy evaluation of 3D lidar data from small UAV

    NASA Astrophysics Data System (ADS)

    Tulldahl, H. M.; Bissmarck, Fredrik; Larsson, Hâkan; Grönwall, Christina; Tolt, Gustav

    2015-10-01

    A UAV (Unmanned Aerial Vehicle) with an integrated lidar can be an efficient system for collection of high-resolution and accurate three-dimensional (3D) data. In this paper we evaluate the accuracy of a system consisting of a lidar sensor on a small UAV. High geometric accuracy in the produced point cloud is a fundamental qualification for detection and recognition of objects in a single-flight dataset as well as for change detection using two or several data collections over the same scene. Our work presented here has two purposes: first to relate the point cloud accuracy to data processing parameters and second, to examine the influence on accuracy from the UAV platform parameters. In our work, the accuracy is numerically quantified as local surface smoothness on planar surfaces, and as distance and relative height accuracy using data from a terrestrial laser scanner as reference. The UAV lidar system used is the Velodyne HDL-32E lidar on a multirotor UAV with a total weight of 7 kg. For processing of data into a geographically referenced point cloud, positioning and orientation of the lidar sensor is based on inertial navigation system (INS) data combined with lidar data. The combination of INS and lidar data is achieved in a dynamic calibration process that minimizes the navigation errors in six degrees of freedom, namely the errors of the absolute position (x, y, z) and the orientation (pitch, roll, yaw) measured by GPS/INS. Our results show that low-cost and light-weight MEMS based (microelectromechanical systems) INS equipment with a dynamic calibration process can obtain significantly improved accuracy compared to processing based solely on INS data.

  15. Classification accuracy on the family planning participation status using kernel discriminant analysis

    NASA Astrophysics Data System (ADS)

    Kurniawan, Dian; Suparti; Sugito

    2018-05-01

    Population growth in Indonesia has increased every year. According to the population census conducted by the Central Bureau of Statistics (BPS) in 2010, the population of Indonesia has reached 237.6 million people. Therefore, to control the population growth rate, the government hold Family Planning or Keluarga Berencana (KB) program for couples of childbearing age. The purpose of this program is to improve the health of mothers and children in order to manifest prosperous society by controlling births while ensuring control of population growth. The data used in this study is the updated family data of Semarang city in 2016 that conducted by National Family Planning Coordinating Board (BKKBN). From these data, classifiers with kernel discriminant analysis will be obtained, and also classification accuracy will be obtained from that method. The result of the analysis showed that normal kernel discriminant analysis gives 71.05 % classification accuracy with 28.95 % classification error. Whereas triweight kernel discriminant analysis gives 73.68 % classification accuracy with 26.32 % classification error. Using triweight kernel discriminant for data preprocessing of family planning participation of childbearing age couples in Semarang City of 2016 can be stated better than with normal kernel discriminant.

  16. Accuracy, resolution, and cost comparisons between small format and mapping cameras for environmental mapping

    NASA Technical Reports Server (NTRS)

    Clegg, R. H.; Scherz, J. P.

    1975-01-01

    Successful aerial photography depends on aerial cameras providing acceptable photographs within cost restrictions of the job. For topographic mapping where ultimate accuracy is required only large format mapping cameras will suffice. For mapping environmental patterns of vegetation, soils, or water pollution, 9-inch cameras often exceed accuracy and cost requirements, and small formats may be better. In choosing the best camera for environmental mapping, relative capabilities and costs must be understood. This study compares resolution, photo interpretation potential, metric accuracy, and cost of 9-inch, 70mm, and 35mm cameras for obtaining simultaneous color and color infrared photography for environmental mapping purposes.

  17. Accuracy of episodic autobiographical memory in children with early thyroid hormone deficiency using a staged event.

    PubMed

    Willoughby, Karen A; McAndrews, Mary Pat; Rovet, Joanne F

    2014-07-01

    Autobiographical memory (AM) is a highly constructive cognitive process that often contains memory errors. No study has specifically examined AM accuracy in children with abnormal development of the hippocampus, a crucial brain region for AM retrieval. Thus, the present study investigated AM accuracy in 68 typically and atypically developing children using a staged autobiographical event, the Children's Autobiographical Interview, and structural magnetic resonance imaging. The atypically developing group consisted of 17 children (HYPO) exposed during gestation to insufficient maternal thyroid hormone (TH), a critical substrate for hippocampal development, and 25 children with congenital hypothyroidism (CH), who were compared to 26 controls. Groups differed significantly in the number of accurate episodic details recalled and proportion accuracy scores, with controls having more accurate recollections of the staged event than both TH-deficient groups. Total hippocampal volumes and anterior hippocampal volumes were positively correlated with proportion accuracy scores, but not total accurate episodic details, in HYPO and CH. In addition, greater severity of TH deficiency predicted lower proportion accuracy scores in both HYPO and CH. Overall, these results indicate that children with early TH deficiency have deficits in AM accuracy and that the anterior hippocampus may play a particularly important role in accurate AM retrieval. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Age-related reduction of the confidence-accuracy relationship in episodic memory: effects of recollection quality and retrieval monitoring.

    PubMed

    Wong, Jessica T; Cramer, Stefanie J; Gallo, David A

    2012-12-01

    We investigated age-related reductions in episodic metamemory accuracy. Participants studied pictures and words in different colors and then took forced-choice recollection tests. These tests required recollection of the earlier presentation color, holding familiarity of the response options constant. Metamemory accuracy was assessed for each participant by comparing recollection test accuracy with corresponding confidence judgments. We found that recollection test accuracy was greater in younger than older adults and also for pictures than font color. Metamemory accuracy tracked each of these recollection differences, as well as individual differences in recollection test accuracy within each age group, suggesting that recollection ability affects metamemory accuracy. Critically, the age-related impairment in metamemory accuracy persisted even when the groups were matched on recollection test accuracy, suggesting that metamemory declines were not entirely due to differences in recollection frequency or quantity, but that differences in recollection quality and/or monitoring also played a role. We also found that age-related impairments in recollection and metamemory accuracy were equivalent for pictures and font colors. This result contrasted with previous false recognition findings, which predicted that older adults would be differentially impaired when monitoring memory for less distinctive memories. These and other results suggest that age-related reductions in metamemory accuracy are not entirely attributable to false recognition effects, but also depend heavily on deficient recollection and/or monitoring of specific details associated with studied stimuli. 2013 APA, all rights reserved

  19. Toward Quantitative Small Animal Pinhole SPECT: Assessment of Quantitation Accuracy Prior to Image Compensations

    PubMed Central

    Chen, Chia-Lin; Wang, Yuchuan; Lee, Jason J. S.; Tsui, Benjamin M. W.

    2011-01-01

    Purpose We assessed the quantitation accuracy of small animal pinhole single photon emission computed tomography (SPECT) under the current preclinical settings, where image compensations are not routinely applied. Procedures The effects of several common image-degrading factors and imaging parameters on quantitation accuracy were evaluated using Monte-Carlo simulation methods. Typical preclinical imaging configurations were modeled, and quantitative analyses were performed based on image reconstructions without compensating for attenuation, scatter, and limited system resolution. Results Using mouse-sized phantom studies as examples, attenuation effects alone degraded quantitation accuracy by up to −18% (Tc-99m or In-111) or −41% (I-125). The inclusion of scatter effects changed the above numbers to −12% (Tc-99m or In-111) and −21% (I-125), respectively, indicating the significance of scatter in quantitative I-125 imaging. Region-of-interest (ROI) definitions have greater impacts on regional quantitation accuracy for small sphere sources as compared to attenuation and scatter effects. For the same ROI, SPECT acquisitions using pinhole apertures of different sizes could significantly affect the outcome, whereas the use of different radii-of-rotation yielded negligible differences in quantitation accuracy for the imaging configurations simulated. Conclusions We have systematically quantified the influence of several factors affecting the quantitation accuracy of small animal pinhole SPECT. In order to consistently achieve accurate quantitation within 5% of the truth, comprehensive image compensation methods are needed. PMID:19048346

  20. High Accuracy, Two-Dimensional Read-Out in Multiwire Proportional Chambers

    DOE R&D Accomplishments Database

    Charpak, G.; Sauli, F.

    1973-02-14

    In most applications of proportional chambers, especially in high-energy physics, separate chambers are used for measuring different coordinates. In general one coordinate is obtained by recording the pulses from the anode wires around which avalanches have grown. Several methods have been imagined for obtaining the position of an avalanche along a wire. In this article a method is proposed which leads to the same range of accuracies and may be preferred in some cases. The problem of accurate measurements for large-size chamber is also discussed.

  1. Error and Uncertainty in the Accuracy Assessment of Land Cover Maps

    NASA Astrophysics Data System (ADS)

    Sarmento, Pedro Alexandre Reis

    Traditionally the accuracy assessment of land cover maps is performed through the comparison of these maps with a reference database, which is intended to represent the "real" land cover, being this comparison reported with the thematic accuracy measures through confusion matrixes. Although, these reference databases are also a representation of reality, containing errors due to the human uncertainty in the assignment of the land cover class that best characterizes a certain area, causing bias in the thematic accuracy measures that are reported to the end users of these maps. The main goal of this dissertation is to develop a methodology that allows the integration of human uncertainty present in reference databases in the accuracy assessment of land cover maps, and analyse the impacts that uncertainty may have in the thematic accuracy measures reported to the end users of land cover maps. The utility of the inclusion of human uncertainty in the accuracy assessment of land cover maps is investigated. Specifically we studied the utility of fuzzy sets theory, more precisely of fuzzy arithmetic, for a better understanding of human uncertainty associated to the elaboration of reference databases, and their impacts in the thematic accuracy measures that are derived from confusion matrixes. For this purpose linguistic values transformed in fuzzy intervals that address the uncertainty in the elaboration of reference databases were used to compute fuzzy confusion matrixes. The proposed methodology is illustrated using a case study in which the accuracy assessment of a land cover map for Continental Portugal derived from Medium Resolution Imaging Spectrometer (MERIS) is made. The obtained results demonstrate that the inclusion of human uncertainty in reference databases provides much more information about the quality of land cover maps, when compared with the traditional approach of accuracy assessment of land cover maps. None

  2. Does the Length of Elbow Flexors and Visual Feedback Have Effect on Accuracy of Isometric Muscle Contraction in Men after Stroke?

    PubMed Central

    Juodzbaliene, Vilma; Darbutas, Tomas; Skurvydas, Albertas

    2016-01-01

    The aim of the study was to determine the effect of different muscle length and visual feedback information (VFI) on accuracy of isometric contraction of elbow flexors in men after an ischemic stroke (IS). Materials and Methods. Maximum voluntary muscle contraction force (MVMCF) and accurate determinate muscle force (20% of MVMCF) developed during an isometric contraction of elbow flexors in 90° and 60° of elbow flexion were measured by an isokinetic dynamometer in healthy subjects (MH, n = 20) and subjects after an IS during their postrehabilitation period (MS, n = 20). Results. In order to evaluate the accuracy of the isometric contraction of the elbow flexors absolute errors were calculated. The absolute errors provided information about the difference between determinate and achieved muscle force. Conclusions. There is a tendency that greater absolute errors generating determinate force are made by MH and MS subjects in case of a greater elbow flexors length despite presence of VFI. Absolute errors also increase in both groups in case of a greater elbow flexors length without VFI. MS subjects make greater absolute errors generating determinate force without VFI in comparison with MH in shorter elbow flexors length. PMID:27042670

  3. Geometric accuracy of Landsat-4 and Landsat-5 Thematic Mapper images.

    USGS Publications Warehouse

    Borgeson, W.T.; Batson, R.M.; Kieffer, H.H.

    1985-01-01

    The geometric accuracy of the Landsat Thematic Mappers was assessed by a linear least-square comparison of the positions of conspicuous ground features in digital images with their geographic locations as determined from 1:24 000-scale maps. For a Landsat-5 image, the single-dimension standard deviations of the standard digital product, and of this image with additional linear corrections, are 11.2 and 10.3 m, respectively (0.4 pixel). An F-test showed that skew and affine distortion corrections are not significant. At this level of accuracy, the granularity of the digital image and the probable inaccuracy of the 1:24 000 maps began to affect the precision of the comparison. The tested image, even with a moderate accuracy loss in the digital-to-graphic conversion, meets National Horizontal Map Accuracy standards for scales of 1:100 000 and smaller. Two Landsat-4 images, obtained with the Multispectral Scanner on and off, and processed by an interim software system, contain significant skew and affine distortions. -Authors

  4. Analysis of the accuracy and robustness of the leap motion controller.

    PubMed

    Weichert, Frank; Bachmann, Daniel; Rudak, Bartholomäus; Fisseler, Denis

    2013-05-14

    The Leap Motion Controller is a new device for hand gesture controlled user interfaces with declared sub-millimeter accuracy. However, up to this point its capabilities in real environments have not been analyzed. Therefore, this paper presents a first study of a Leap Motion Controller. The main focus of attention is on the evaluation of the accuracy and repeatability. For an appropriate evaluation, a novel experimental setup was developed making use of an industrial robot with a reference pen allowing a position accuracy of 0.2 mm. Thereby, a deviation between a desired 3D position and the average measured positions below 0.2 mm has been obtained for static setups and of 1.2 mm for dynamic setups. Using the conclusion of this analysis can improve the development of applications for the Leap Motion controller in the field of Human-Computer Interaction.

  5. Modelling Accuracy of a Car Steering Mechanism with Rack and Pinion and McPherson Suspension

    NASA Astrophysics Data System (ADS)

    Knapczyk, J.; Kucybała, P.

    2016-08-01

    Modelling accuracy of a car steering mechanism with a rack and pinion and McPherson suspension is analyzed. Geometrical parameters of the model are described by using the coordinates of centers of spherical joints, directional unit vectors and axis points of revolute, cylindrical and prismatic joints. Modelling accuracy is assumed as the differences between the values of the wheel knuckle position and orientation coordinates obtained using a simulation model and the corresponding measured values. The sensitivity analysis of the parameters on the model accuracy is illustrated by two numerical examples.

  6. Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV).

    PubMed

    Jarrahian, Courtney; Rein-Weston, Annie; Saxon, Gene; Creelman, Ben; Kachmarik, Greg; Anand, Abhijeet; Zehrung, Darin

    2017-03-27

    Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall

  7. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., measurement accuracy, and cut-off. 53.53 Section 53.53 Protection of Environment ENVIRONMENTAL PROTECTION..., measurement accuracy, and cut-off. (a) Overview. This test procedure is designed to evaluate a candidate... measurement accuracy, coefficient of variability measurement accuracy, and the flow rate cut-off function. The...

  8. The accuracy of the Gaussian-and-finite-element-Coulomb (GFC) method for the calculation of Coulomb integrals.

    PubMed

    Przybytek, Michal; Helgaker, Trygve

    2013-08-07

    We analyze the accuracy of the Coulomb energy calculated using the Gaussian-and-finite-element-Coulomb (GFC) method. In this approach, the electrostatic potential associated with the molecular electronic density is obtained by solving the Poisson equation and then used to calculate matrix elements of the Coulomb operator. The molecular electrostatic potential is expanded in a mixed Gaussian-finite-element (GF) basis set consisting of Gaussian functions of s symmetry centered on the nuclei (with exponents obtained from a full optimization of the atomic potentials generated by the atomic densities from symmetry-averaged restricted open-shell Hartree-Fock theory) and shape functions defined on uniform finite elements. The quality of the GF basis is controlled by means of a small set of parameters; for a given width of the finite elements d, the highest accuracy is achieved at smallest computational cost when tricubic (n = 3) elements are used in combination with two (γ(H) = 2) and eight (γ(1st) = 8) Gaussians on hydrogen and first-row atoms, respectively, with exponents greater than a given threshold (αmin (G)=0.5). The error in the calculated Coulomb energy divided by the number of atoms in the system depends on the system type but is independent of the system size or the orbital basis set, vanishing approximately like d(4) with decreasing d. If the boundary conditions for the Poisson equation are calculated in an approximate way, the GFC method may lose its variational character when the finite elements are too small; with larger elements, it is less sensitive to inaccuracies in the boundary values. As it is possible to obtain accurate boundary conditions in linear time, the overall scaling of the GFC method for large systems is governed by another computational step-namely, the generation of the three-center overlap integrals with three Gaussian orbitals. The most unfavorable (nearly quadratic) scaling is observed for compact, truly three-dimensional systems

  9. Effect of dental technician disparities on the 3-dimensional accuracy of definitive casts.

    PubMed

    Emir, Faruk; Piskin, Bulent; Sipahi, Cumhur

    2017-03-01

    Studies that evaluated the effect of dental technician disparities on the accuracy of presectioned and postsectioned definitive casts are lacking. The purpose of this in vitro study was to evaluate the accuracy of presectioned and postsectioned definitive casts fabricated by different dental technicians by using a 3-dimensional computer-aided measurement method. An arch-shaped metal master model consisting of 5 abutments resembling prepared mandibular incisors, canines, and first molars and with a 6-degree total angle of convergence was designed and fabricated by computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Complete arch impressions were made (N=110) from the master model, using polyvinyl siloxane (PVS) and delivered to 11 dental technicians. Each technician fabricated 10 definitive casts with dental stone, and the obtained casts were numbered. All casts were sectioned, and removable dies were obtained. The master model and the presectioned and postsectioned definitive casts were digitized with an extraoral scanner, and the virtual master model and virtual presectioned and postsectioned definitive casts were obtained. All definitive casts were compared with the master model by using computer-aided measurements, and the 3-dimensional accuracy of the definitive casts was determined with best fit alignment and represented in color-coded maps. Differences were analyzed using univariate analyses of variance, and the Tukey honest significant differences post hoc tests were used for multiple comparisons (α=.05). The accuracy of presectioned and postsectioned definitive casts was significantly affected by dental technician disparities (P<.001). The largest dimensional changes were detected in the anterior abutments of both of the definitive casts. The changes mostly occurred in the mesiodistal dimension (P<.001). Within the limitations of this in vitro study, the accuracy of presectioned and postsectioned definitive casts is susceptible

  10. Attitude-correlated frames approach for a star sensor to improve attitude accuracy under highly dynamic conditions.

    PubMed

    Ma, Liheng; Zhan, Dejun; Jiang, Guangwen; Fu, Sihua; Jia, Hui; Wang, Xingshu; Huang, Zongsheng; Zheng, Jiaxing; Hu, Feng; Wu, Wei; Qin, Shiqiao

    2015-09-01

    The attitude accuracy of a star sensor decreases rapidly when star images become motion-blurred under dynamic conditions. Existing techniques concentrate on a single frame of star images to solve this problem and improvements are obtained to a certain extent. An attitude-correlated frames (ACF) approach, which concentrates on the features of the attitude transforms of the adjacent star image frames, is proposed to improve upon the existing techniques. The attitude transforms between different star image frames are measured by the strap-down gyro unit precisely. With the ACF method, a much larger star image frame is obtained through the combination of adjacent frames. As a result, the degradation of attitude accuracy caused by motion-blurring are compensated for. The improvement of the attitude accuracy is approximately proportional to the square root of the number of correlated star image frames. Simulations and experimental results indicate that the ACF approach is effective in removing random noises and improving the attitude determination accuracy of the star sensor under highly dynamic conditions.

  11. Accuracy of digital and analogue cephalometric measurements assessed with the sandwich technique.

    PubMed

    Santoro, Margherita; Jarjoura, Karim; Cangialosi, Thomas J

    2006-03-01

    The purpose of the study was to evaluate the accuracy of cephalometric measurements obtained with digital tracing software compared with equivalent hand-traced measurements. In the sandwich technique, a storage phosphor plate and a conventional radiographic film are placed in the same cassette and exposed simultaneously. The method eliminates positioning errors and potential differences associated with multiple radiographic exposures that affected previous studies. It was used to ensure the equivalence of the digital images to the hard copy radiographs. Cephalometric measurements instead of landmarks were the focus of this investigation in order to acquire data with direct clinical applications. The sample consisted of digital and analog radiographic images from 47 patients after orthodontic treatment. Nine cephalometric landmarks were identified and 13 measurements calculated by 1 operator, both manually and with digital tracing software. Measurement error was assessed for each method by duplicating measurements of 25 randomly selected radiographs and by using Pearson's correlation coefficient. A paired t test was used to detect differences between the manual and digital methods. An overall greater variability in the digital cephalometric measurements was found. Differences between the 2 methods for SNA, ANB, S-Go:N-Me, U1/L1, L1-GoGn, and N-ANS:ANS-Me were statistically significant (P < .05). However, only the U1/L1 and S-Go:N-Me measurements showed differences greater than 2 SE (P < .0001). The 2 tracing methods provide similar clinical results; therefore, efficient digital cephalometric software can be reliably chosen as a routine diagnostic tool. The user-friendly sandwich technique was effective as an option for interoffice communications.

  12. Accuracy criteria voltage electrocardiography left ventricular hypertrophy to distinguish types of left ventricular hypertrophy geometry

    NASA Astrophysics Data System (ADS)

    Tumbur, O.; Safri, Z.; Hassan, R.

    2018-03-01

    Different types of left ventricular hypertrophy geometry are associated with different risk of cardiovascular disease. The purpose of this study was to determine the role of various ECG voltages of LVH to distinguish the type of LVH geometry. A cross-sectional study from June to November 2015, 100 patients in Adam Malik Hospital Medan. The result of LVH ECG criteria of Sokolow-Lyon was not met then obtained normal left ventricular geometry with 60% sensitivity, 72.22% specificity, and 71% accuracy. The eccentric type of LVH is obtained when the Cornel Voltage is not met; the sensitivity is 25%, specificity 71.88%, and 55% accuracy. Concentric geometric hypertrophy when the RV6/V5> 1 ratio is satisfied, the sensitivity is 55.56%, specificity 56.36%, and 56% accuracy. The RV6/V5>1 ratio was not met, the concentric geometry type of hypertrophy remodeling was determined with a sensitivity of 55.56%, specificity 49.45%, and 50% accuracy. Conclusions, various LVHECG criteria distinguish the type of LVH geometry. Sokolow-Lyon and Cornel Voltage sensitivity and specificity are better than the RV6/V5 ratio.

  13. Accuracy and Reproducibility of Adipose Tissue Measurements in Young Infants by Whole Body Magnetic Resonance Imaging

    PubMed Central

    Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans

    2015-01-01

    Purpose MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. Material and Methods MR images of ten phantoms simulating subcutaneous fat of an infant’s torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. Results In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. Conclusion With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy. PMID:25706876

  14. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    PubMed

    Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans

    2015-01-01

    MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  15. On the Gibbs phenomenon 4: Recovering exponential accuracy in a sub-interval from a Gegenbauer partial sum of a piecewise analytic function

    NASA Technical Reports Server (NTRS)

    Gottlieb, David; Shu, Chi-Wang

    1994-01-01

    We continue our investigation of overcoming Gibbs phenomenon, i.e., to obtain exponential accuracy at all points (including at the discontinuities themselves), from the knowledge of a spectral partial sum of a discontinuous but piecewise analytic function. We show that if we are given the first N Gegenbauer expansion coefficients, based on the Gegenbauer polynomials C(sub k)(sup mu)(x) with the weight function (1 - x(exp 2))(exp mu - 1/2) for any constant mu is greater than or equal to 0, of an L(sub 1) function f(x), we can construct an exponentially convergent approximation to the point values of f(x) in any subinterval in which the function is analytic. The proof covers the cases of Chebyshev or Legendre partial sums, which are most common in applications.

  16. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques.

    PubMed

    Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A

    2018-05-01

    This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p  ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p  ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. High-accuracy reference standards for two-photon absorption in the 680–1050 nm wavelength range

    PubMed Central

    de Reguardati, Sophie; Pahapill, Juri; Mikhailov, Alexander; Stepanenko, Yuriy; Rebane, Aleksander

    2016-01-01

    Degenerate two-photon absorption (2PA) of a series of organic fluorophores is measured using femtosecond fluorescence excitation method in the wavelength range, λ2PA = 680–1050 nm, and ~100 MHz pulse repetition rate. The function of relative 2PA spectral shape is obtained with estimated accuracy 5%, and the absolute 2PA cross section is measured at selected wavelengths with the accuracy 8%. Significant improvement of the accuracy is achieved by means of rigorous evaluation of the quadratic dependence of the fluorescence signal on the incident photon flux in the whole wavelength range, by comparing results obtained from two independent experiments, as well as due to meticulous evaluation of critical experimental parameters, including the excitation spatial- and temporal pulse shape, laser power and sample geometry. Application of the reference standards in nonlinear transmittance measurements is discussed. PMID:27137334

  18. Occupational exposure decisions: can limited data interpretation training help improve accuracy?

    PubMed

    Logan, Perry; Ramachandran, Gurumurthy; Mulhausen, John; Hewett, Paul

    2009-06-01

    Accurate exposure assessments are critical for ensuring that potentially hazardous exposures are properly identified and controlled. The availability and accuracy of exposure assessments can determine whether resources are appropriately allocated to engineering and administrative controls, medical surveillance, personal protective equipment and other programs designed to protect workers. A desktop study was performed using videos, task information and sampling data to evaluate the accuracy and potential bias of participants' exposure judgments. Desktop exposure judgments were obtained from occupational hygienists for material handling jobs with small air sampling data sets (0-8 samples) and without the aid of computers. In addition, data interpretation tests (DITs) were administered to participants where they were asked to estimate the 95th percentile of an underlying log-normal exposure distribution from small data sets. Participants were presented with an exposure data interpretation or rule of thumb training which included a simple set of rules for estimating 95th percentiles for small data sets from a log-normal population. DIT was given to each participant before and after the rule of thumb training. Results of each DIT and qualitative and quantitative exposure judgments were compared with a reference judgment obtained through a Bayesian probabilistic analysis of the sampling data to investigate overall judgment accuracy and bias. There were a total of 4386 participant-task-chemical judgments for all data collections: 552 qualitative judgments made without sampling data and 3834 quantitative judgments with sampling data. The DITs and quantitative judgments were significantly better than random chance and much improved by the rule of thumb training. In addition, the rule of thumb training reduced the amount of bias in the DITs and quantitative judgments. The mean DIT % correct scores increased from 47 to 64% after the rule of thumb training (P < 0.001). The

  19. Assessing the geologic evolution of Greater Thaumasia, Mars

    NASA Astrophysics Data System (ADS)

    Hood, Don R.; Judice, Taylor; Karunatillake, Suniti; Rogers, Deanne; Dohm, James M.; Susko, David; Carnes, Lorraine K.

    2016-09-01

    The Greater Thaumasia region consists of three chemical provinces that include Syria, Solis, and Thaumasia Planae, the Corprates Rise, part of the Thaumasia Highlands, and the transition zone northwest of the Argyre basin. Chemical signatures obtained from the Mars Odyssey Gamma Ray Spectrometer suggest low abundances of K and Th to the west, with low H abundances and high Si abundances to the east, relative to the bulk Martian crust at midlatitudes. These observations are confirmed and quantified with a modified box and whisker analysis that simultaneously captures the degree of deviation and significance of the regionally anomalous chemistry. Motivated by regionally unique chemistry, as well as its diverse geological history, we characterize Greater Thaumasia in terms of chemistry, mineralogy, and mapped geology to determine how such complementary data record the evolution of this region. Our observations are inconsistent with a proposed salt-lubricated landslide origin, particularly given the lack of chemical or mineralogical signatures to support near-surface salt deposits that should arise over geological timescales. Our observations instead support magmatic processes, such as mantle evolution over geological time, which may impart the Si-enriched signature of the eastern portion of Greater Thaumasia as well as the K and Th depletion of the southeastern flank of Syria Planum. While the observed trend of decreasing K and Th from Noachian to Hesperian lavas is inconsistent with previous models of Martian mantle evolution, we see an increase in Ca content at the Noachian-Hesperian boundary, consistent with predictions from thermodynamic modeling.

  20. Analysis of the Accuracy and Robustness of the Leap Motion Controller

    PubMed Central

    Weichert, Frank; Bachmann, Daniel; Rudak, Bartholomäus; Fisseler, Denis

    2013-01-01

    The Leap Motion Controller is a new device for hand gesture controlled user interfaces with declared sub-millimeter accuracy. However, up to this point its capabilities in real environments have not been analyzed. Therefore, this paper presents a first study of a Leap Motion Controller. The main focus of attention is on the evaluation of the accuracy and repeatability. For an appropriate evaluation, a novel experimental setup was developed making use of an industrial robot with a reference pen allowing a position accuracy of 0.2 mm. Thereby, a deviation between a desired 3D position and the average measured positions below 0.2 mm has been obtained for static setups and of 1.2 mm for dynamic setups. Using the conclusion of this analysis can improve the development of applications for the Leap Motion controller in the field of Human-Computer Interaction. PMID:23673678

  1. Effect of Reduced Tube Voltage on Diagnostic Accuracy of CT Colonography.

    PubMed

    Futamata, Yoshihiro; Koide, Tomoaki; Ihara, Riku

    2017-01-01

    The normal tube voltage in computed tomography colonography (CTC) is 120 kV. Some reports indicate that the use of a low tube voltage (lower than 120 kV) technique plays a significant role in reduction of radiation dose. However, to determine whether a lower tube voltage can reduce radiation dose without compromising diagnostic accuracy, an evaluation of images that are obtained while maintaining the volume CT dose index (CTDI vol ) is required. This study investigated the effect of reduced tube voltage in CTC, without modifying radiation dose (i.e. constant CTDI vol ), on image quality. Evaluation of image quality involved the shape of the noise power spectrum, surface profiling with volume rendering (VR), and receiver operating characteristic (ROC) analysis. The shape of the noise power spectrum obtained with a tube voltage of 80 kV and 100 kV was not similar to the one produced with a tube voltage of 120 kV. Moreover, a higher standard deviation was observed on volume-rendered images that were generated using the reduced tube voltages. In addition, ROC analysis revealed a statistically significant drop in diagnostic accuracy with reduced tube voltage, revealing that the modification of tube voltage affects volume-rendered images. The results of this study suggest that reduction of tube voltage in CTC, so as to reduce radiation dose, affects image quality and diagnostic accuracy.

  2. Principles of operation, accuracy and precision of an Eye Surface Profiler.

    PubMed

    Iskander, D Robert; Wachel, Pawel; Simpson, Patrick N D; Consejo, Alejandra; Jesus, Danilo A

    2016-05-01

    To introduce a newly developed instrument for measuring the topography of the anterior eye, provide principles of its operation and to assess its accuracy and precision. The Eye Surface Profiler is a new technology based on Fourier transform profilometry for measuring the anterior eye surface encompassing the corneo-scleral area. Details of technical principles of operation are provided for the particular case of sequential double fringe projection. Technical limits of accuracy have been assessed for several key parameters such as the carrier frequency, image quantisation level, sensor size, carrier frequency inaccuracy, and level and type of noise. Further, results from both artificial test surfaces as well as real eyes are used to assess precision and accuracy of the device (here benchmarked against one of popular Placido disk videokeratoscopes). Technically, the Eye Surface Profiler accuracy can reach levels below 1 μm for a range of considered key parameters. For the unit tested and using calibrated artificial surfaces, the accuracy of measurement (in terms of RMS error) was below 10 μm for a central measurement area of 8 mm diameter and below 40 μm for an extended measurement area of 16 mm. In some cases, the error reached levels of up to 200 μm at the very periphery of the measured surface (up to 20 mm). The SimK estimates of the test surfaces from the Eye Surface Profiler were in close agreement with those from a Placido disk videokeratoscope with differences no greater than ±0.1 D. For real eyes, the benchmarked accuracy was within ±0.5D for both the spherical and cylindrical SimK components. The Eye Surface Profiler can successfully measure the topography of the entire anterior eye including the cornea, limbus and sclera. It has a great potential to become an optometry clinical tool that could substitute the currently used videokeratoscopes and provide a high quality corneo-scleral topography. © 2016 The Authors Ophthalmic & Physiological

  3. Spinal intra-operative three-dimensional navigation with infra-red tool tracking: correlation between clinical and absolute engineering accuracy

    NASA Astrophysics Data System (ADS)

    Guha, Daipayan; Jakubovic, Raphael; Gupta, Shaurya; Yang, Victor X. D.

    2017-02-01

    Computer-assisted navigation (CAN) may guide spinal surgeries, reliably reducing screw breach rates. Definitions of screw breach, if reported, vary widely across studies. Absolute quantitative error is theoretically a more precise and generalizable metric of navigation accuracy, but has been computed variably and reported in fewer than 25% of clinical studies of CAN-guided pedicle screw accuracy. We reviewed a prospectively-collected series of 209 pedicle screws placed with CAN guidance to characterize the correlation between clinical pedicle screw accuracy, based on postoperative imaging, and absolute quantitative navigation accuracy. We found that acceptable screw accuracy was achieved for significantly fewer screws based on 2mm grade vs. Heary grade, particularly in the lumbar spine. Inter-rater agreement was good for the Heary classification and moderate for the 2mm grade, significantly greater among radiologists than surgeon raters. Mean absolute translational/angular accuracies were 1.75mm/3.13° and 1.20mm/3.64° in the axial and sagittal planes, respectively. There was no correlation between clinical and absolute navigation accuracy, in part because surgeons appear to compensate for perceived translational navigation error by adjusting screw medialization angle. Future studies of navigation accuracy should therefore report absolute translational and angular errors. Clinical screw grades based on post-operative imaging, if reported, may be more reliable if performed in multiple by radiologist raters.

  4. Accuracy of Self-Esteem Judgments at Zero Acquaintance.

    PubMed

    Hirschmüller, Sarah; Schmukle, Stefan C; Krause, Sascha; Back, Mitja D; Egloff, Boris

    2018-04-01

    Perceptions of strangers' self-esteem can have wide-ranging interpersonal consequences. Aiming to reconcile inconsistent results from previous research that had predominantly suggested that self-esteem is a trait that can hardly be accurately judged at zero acquaintance, we examined unaquainted others' accuracy in inferring individuals' actual self-esteem. Ninety-nine target participants (77 female; M age  = 23.5 years) were videotaped in a self-introductory situation, and self-esteem self-reports and reports by well-known informants were obtained as separate accuracy criteria. Forty unacquainted observers judged targets' self-esteem on the basis of these short video sequences (M = 23s, SD = 7.7). Results showed that both self-reported (r = .31, p = .002) and informant-reported self-esteem (r = .21, p = .040) of targets could be inferred by strangers. The degree of accuracy in self-esteem judgments could be explained with lens model analyses: Self- and informant-reported self-esteem predicted nonverbal and vocal friendliness, both of which predicted self-esteem judgments by observers. In addition, observers' accuracy in inferring informant-reported self-esteem was mediated by the utilization of targets' physical attractiveness. Besides using valid behavioral information to infer strangers' self-esteem, observers inappropriately relied on invalid behavioral information reflecting nonverbal, vocal, and verbal self-assuredness. Our findings show that strangers can quite accurately detect individuals' self-reported and informant-reported self-esteem when targets are observed in a public self-presentational situation. © 2017 Wiley Periodicals, Inc.

  5. Verification and classification bias interactions in diagnostic test accuracy studies for fine-needle aspiration biopsy.

    PubMed

    Schmidt, Robert L; Walker, Brandon S; Cohen, Michael B

    2015-03-01

    Reliable estimates of accuracy are important for any diagnostic test. Diagnostic accuracy studies are subject to unique sources of bias. Verification bias and classification bias are 2 sources of bias that commonly occur in diagnostic accuracy studies. Statistical methods are available to estimate the impact of these sources of bias when they occur alone. The impact of interactions when these types of bias occur together has not been investigated. We developed mathematical relationships to show the combined effect of verification bias and classification bias. A wide range of case scenarios were generated to assess the impact of bias components and interactions on total bias. Interactions between verification bias and classification bias caused overestimation of sensitivity and underestimation of specificity. Interactions had more effect on sensitivity than specificity. Sensitivity was overestimated by at least 7% in approximately 6% of the tested scenarios. Specificity was underestimated by at least 7% in less than 0.1% of the scenarios. Interactions between verification bias and classification bias create distortions in accuracy estimates that are greater than would be predicted from each source of bias acting independently. © 2014 American Cancer Society.

  6. Requirements for Coregistration Accuracy in On-Scalp MEG.

    PubMed

    Zetter, Rasmus; Iivanainen, Joonas; Stenroos, Matti; Parkkonen, Lauri

    2018-06-22

    Recent advances in magnetic sensing has made on-scalp magnetoencephalography (MEG) possible. In particular, optically-pumped magnetometers (OPMs) have reached sensitivity levels that enable their use in MEG. In contrast to the SQUID sensors used in current MEG systems, OPMs do not require cryogenic cooling and can thus be placed within millimetres from the head, enabling the construction of sensor arrays that conform to the shape of an individual's head. To properly estimate the location of neural sources within the brain, one must accurately know the position and orientation of sensors in relation to the head. With the adaptable on-scalp MEG sensor arrays, this coregistration becomes more challenging than in current SQUID-based MEG systems that use rigid sensor arrays. Here, we used simulations to quantify how accurately one needs to know the position and orientation of sensors in an on-scalp MEG system. The effects that different types of localisation errors have on forward modelling and source estimates obtained by minimum-norm estimation, dipole fitting, and beamforming are detailed. We found that sensor position errors generally have a larger effect than orientation errors and that these errors affect the localisation accuracy of superficial sources the most. To obtain similar or higher accuracy than with current SQUID-based MEG systems, RMS sensor position and orientation errors should be [Formula: see text] and [Formula: see text], respectively.

  7. Preliminary GAOFEN-3 Insar dem Accuracy Analysis

    NASA Astrophysics Data System (ADS)

    Chen, Q.; Li, T.; Tang, X.; Gao, X.; Zhang, X.

    2018-04-01

    GF-3 satellite, the first C band and full-polarization SAR satellite of China with spatial resolution of 1 m, was successfully launched in August 2016. We analyze the error sources of GF-3 satellite in this paper, and provide the interferometric calibration model based on range function, Doppler shift equation and interferometric phase function, and interferometric parameters calibrated using the three-dimensional coordinates of ground control points. Then, we conduct the experimental two pairs of images in fine stripmap I mode covering Songshan of Henan Province and Tangshan of Hebei Province, respectively. The DEM data are assessed using SRTM DEM, ICESat-GLAS points, and ground control points database obtained using ZY-3 satellite to validate the accuracy of DEM elevation. The experimental results show that the accuracy of DEM extracted from GF-3 satellite SAR data can meet the requirements of topographic mapping in mountain and alpine regions at the scale of 1 : 50000 in China. Besides, it proves that GF-3 satellite has the potential of interferometry.

  8. Ab Initio Density Fitting: Accuracy Assessment of Auxiliary Basis Sets from Cholesky Decompositions.

    PubMed

    Boström, Jonas; Aquilante, Francesco; Pedersen, Thomas Bondo; Lindh, Roland

    2009-06-09

    The accuracy of auxiliary basis sets derived by Cholesky decompositions of the electron repulsion integrals is assessed in a series of benchmarks on total ground state energies and dipole moments of a large test set of molecules. The test set includes molecules composed of atoms from the first three rows of the periodic table as well as transition metals. The accuracy of the auxiliary basis sets are tested for the 6-31G**, correlation consistent, and atomic natural orbital basis sets at the Hartree-Fock, density functional theory, and second-order Møller-Plesset levels of theory. By decreasing the decomposition threshold, a hierarchy of auxiliary basis sets is obtained with accuracies ranging from that of standard auxiliary basis sets to that of conventional integral treatments.

  9. Accuracy and Measurement Error of the Medial Clear Space of the Ankle.

    PubMed

    Metitiri, Ogheneochuko; Ghorbanhoseini, Mohammad; Zurakowski, David; Hochman, Mary G; Nazarian, Ara; Kwon, John Y

    2017-04-01

    Measurement of the medial clear space (MCS) is commonly used to assess deltoid ligament competency and mortise stability when managing ankle fractures. Lacking knowledge of the true anatomic width measured, previous studies have been unable to measure accuracy of measurement. The purpose of this study was to determine MCS measurement error and accuracy and any influencing factors. Using 3 normal transtibial ankle cadaver specimens, deltoid and syndesmotic ligaments were transected and the mortise widened and affixed at a width of 6 mm (specimen 1) and 4 mm (specimen 2). The mortise was left intact in specimen 3. Radiographs were obtained of each cadaver at varying degrees of rotation. Radiographs were randomized, and providers measured the MCS using a standardized technique. Lack of accuracy as well as lack of precision in measurement of the medial clear space compared to a known anatomic value was present for all 3 specimens tested. There were no significant differences in mean delta with regard to level of training for specimens 1 and 2; however, with specimen 3, staff physicians showed increased measurement accuracy compared with trainees. Accuracy and precision of MCS measurements are poor. Provider experience did not appear to influence accuracy and precision of measurements for the displaced mortise. This high degree of measurement error and lack of precision should be considered when deciding treatment options based on MCS measurements.

  10. Two high accuracy digital integrators for Rogowski current transducers.

    PubMed

    Luo, Pan-dian; Li, Hong-bin; Li, Zhen-hua

    2014-01-01

    The Rogowski current transducers have been widely used in AC current measurement, but their accuracy is mainly subject to the analog integrators, which have typical problems such as poor long-term stability and being susceptible to environmental conditions. The digital integrators can be another choice, but they cannot obtain a stable and accurate output for the reason that the DC component in original signal can be accumulated, which will lead to output DC drift. Unknown initial conditions can also result in integral output DC offset. This paper proposes two improved digital integrators used in Rogowski current transducers instead of traditional analog integrators for high measuring accuracy. A proportional-integral-derivative (PID) feedback controller and an attenuation coefficient have been applied in improving the Al-Alaoui integrator to change its DC response and get an ideal frequency response. For the special design in the field of digital signal processing, the improved digital integrators have better performance than analog integrators. Simulation models are built for the purpose of verification and comparison. The experiments prove that the designed integrators can achieve higher accuracy than analog integrators in steady-state response, transient-state response, and temperature changing condition.

  11. Two high accuracy digital integrators for Rogowski current transducers

    NASA Astrophysics Data System (ADS)

    Luo, Pan-dian; Li, Hong-bin; Li, Zhen-hua

    2014-01-01

    The Rogowski current transducers have been widely used in AC current measurement, but their accuracy is mainly subject to the analog integrators, which have typical problems such as poor long-term stability and being susceptible to environmental conditions. The digital integrators can be another choice, but they cannot obtain a stable and accurate output for the reason that the DC component in original signal can be accumulated, which will lead to output DC drift. Unknown initial conditions can also result in integral output DC offset. This paper proposes two improved digital integrators used in Rogowski current transducers instead of traditional analog integrators for high measuring accuracy. A proportional-integral-derivative (PID) feedback controller and an attenuation coefficient have been applied in improving the Al-Alaoui integrator to change its DC response and get an ideal frequency response. For the special design in the field of digital signal processing, the improved digital integrators have better performance than analog integrators. Simulation models are built for the purpose of verification and comparison. The experiments prove that the designed integrators can achieve higher accuracy than analog integrators in steady-state response, transient-state response, and temperature changing condition.

  12. Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography

    PubMed Central

    Oguma, Tsuyoshi; Hirai, Toyohiro; Niimi, Akio; Matsumoto, Hisako; Muro, Shigeo; Shigematsu, Michio; Nishimura, Takashi; Kubo, Yoshiro; Mishima, Michiaki

    2013-01-01

    Objectives (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. Methods An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai), and the wall area percentage (WA%). To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. Results Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001), and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. Conclusions The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner. PMID:24116105

  13. Do greater mouse-eared bats experience a trade-off between energy conservation and learning?

    PubMed

    Ruczyński, Ireneusz; Clarin, Theresa M A; Siemers, Bjoern M

    2014-11-15

    Bats, some species of rodents and some birds are able to save energy during the summer period by decreasing their body temperature and falling into torpor. Some studies indicate that torpor prevents sleeping and causes effects similar to sleep deprivation. Impairment of processes stabilizing memory slows down learning accuracy and speed. We conducted two experiments to test whether greater mouse-eared bats, Myotis myotis, which commonly use torpor during the summer period, experience a trade-off between energy savings and learning abilities. We compared learning speed and accuracy in bats that were exposed to low (7°C) and higher ambient temperatures (22°C) between training and experimental sessions. Tests were conducted in experiments with food reward (food search) and without food reward (perch search). Time spent with the skin temperature above 30°C was significantly longer for bats exposed to 22°C than for those exposed to 7°C, and longer in experiments with food reward than without food reward. We observed only a very weak tendency for better accuracy and shorter search times in bats exposed to 22°C than in those exposed to 7°C. Our data indicate that memory consolidation of bats under natural conditions is not affected by daily torpor when bats are in good condition and may therefore defend against a rapid fall into torpor. We suggest that homeostatic processes connected with the circadian rhythm allow protection of the consolidation of memory for relatively simple tasks despite time spent in torpor. © 2014. Published by The Company of Biologists Ltd.

  14. Oxygen cost of exercise hyperpnoea is greater in women compared with men

    PubMed Central

    Dominelli, Paolo B; Render, Jacqueline N; Molgat-Seon, Yannick; Foster, Glen E; Romer, Lee M; Sheel, A William

    2015-01-01

    We compared the oxygen cost of breathing () in healthy men and women over a wide range of exercise ventilations (). Eighteen subjects (nine women) completed 4 days of testing. First, a step-wise maximal cycle exercise test was completed for the assessment of spontaneous breathing patterns. Next, subjects were familiarized with the voluntary hyperpnoea protocol used to estimate . During the final two visits, subjects mimicked multiple times (four to six) the breathing patterns associated with five or six different exercise stages. Each trial lasted 5 min, and on-line pressure–volume and flow–volume loops were superimposed on target loops obtained during exercise to replicate the work of breathing accurately. At ∼55 l min−1 , was significantly greater in women. At maximal ventilation, the absolute was not different (P > 0.05) between the sexes, but represented a significantly greater fraction of whole-body in women (13.8 ± 1.5 vs. 9.4 ± 1.1% ). During heavy exercise at 92 and 100% , the unit cost of was +0.7 and +1.1 ml O2 l−1 greater in women (P < 0.05). At , men and women who developed expiratory flow limitation had a significantly greater than those who did not (435 ± 44 vs. 331 ± 30 ml O2 min−1). In conclusion, women have a greater for a given , and this represents a greater fraction of whole-body . The greater in women may have implications for the integrated physiological response to exercise. PMID:25652549

  15. Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.

    PubMed

    Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu

    2018-04-01

    Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.

  16. Accuracy assessment of percent canopy cover, cover type, and size class

    Treesearch

    H. T. Schreuder; S. Bain; R. C. Czaplewski

    2003-01-01

    Truth for vegetation cover percent and type is obtained from very large-scale photography (VLSP), stand structure as measured by size classes, and vegetation types from a combination of VLSP and ground sampling. We recommend using the Kappa statistic with bootstrap confidence intervals for overall accuracy, and similarly bootstrap confidence intervals for percent...

  17. Polysyllable Speech Accuracy and Predictors of Later Literacy Development in Preschool Children With Speech Sound Disorders.

    PubMed

    Masso, Sarah; Baker, Elise; McLeod, Sharynne; Wang, Cen

    2017-07-12

    The aim of this study was to determine if polysyllable accuracy in preschoolers with speech sound disorders (SSD) was related to known predictors of later literacy development: phonological processing, receptive vocabulary, and print knowledge. Polysyllables-words of three or more syllables-are important to consider because unlike monosyllables, polysyllables have been associated with phonological processing and literacy difficulties in school-aged children. They therefore have the potential to help identify preschoolers most at risk of future literacy difficulties. Participants were 93 preschool children with SSD from the Sound Start Study. Participants completed the Polysyllable Preschool Test (Baker, 2013) as well as phonological processing, receptive vocabulary, and print knowledge tasks. Cluster analysis was completed, and 2 clusters were identified: low polysyllable accuracy and moderate polysyllable accuracy. The clusters were significantly different based on 2 measures of phonological awareness and measures of receptive vocabulary, rapid naming, and digit span. The clusters were not significantly different on sound matching accuracy or letter, sound, or print concept knowledge. The participants' poor performance on print knowledge tasks suggested that as a group, they were at risk of literacy difficulties but that there was a cluster of participants at greater risk-those with both low polysyllable accuracy and poor phonological processing.

  18. Accuracy of real time radiography burning rate measurement

    NASA Astrophysics Data System (ADS)

    Olaniyi, Bisola

    The design of a solid propellant rocket motor requires the determination of a propellant's burning-rate and its dependency upon environmental parameters. The requirement that the burning-rate be physically measured, establishes the need for methods and equipment to obtain such data. A literature review reveals that no measurement has provided the desired burning rate accuracy. In the current study, flash x-ray modeling and digitized film-density data were employed to predict motor-port area to length ratio. The pre-fired port-areas and base burning rate were within 2.5% and 1.2% of their known values, respectively. To verify the accuracy of the method, a continuous x-ray and a solid propellant rocket motor model (Plexiglas cylinder) were used. The solid propellant motor model was translated laterally through a real-time radiography system at different speeds simulating different burning rates. X-ray images were captured and the burning-rate was then determined. The measured burning rate was within 1.65% of the known values.

  19. Different Pattern of Inflammatory and Atrophic Changes in the Gastric Mucosa of the Greater and Lesser Curvature.

    PubMed

    Isajevs, Sergejs; Liepniece-Karele, Inta; Svirina, Darja; Santare, Daiga; Kaidaks, Sandris; Sivins, Armands; Vikmanis, Uldis; Leja, Marcis

    2015-12-01

    Appropriate biopsy sampling is important for the classification of gastritis, yet the extent of inflammation and atrophy of different regions of the stomach with chronic gastritis have been addressed only in a few studies. The aim of our study was to analyze the inflammatory, atrophic and metaplastic changes in the greater and lesser curvature of the antrum and corpus mucosa. 420 patients undergoing upper endoscopy were enrolled in the study. Four expert gastrointestinal pathologists graded biopsy specimens according to the updated Sydney classification. The obtained results showed that the mononuclear and granulocyte inflammatory cells were more prominent in the corpus lesser curvature compared to the corpus greater curvature (p=0.01 and p=0.0001, respectively). In addition, the extent and degree of atrophy and intestinal metaplasia were more prominent in the corpus lesser compared to the greater curvature (p=0.002 and p=0.0065, respectively). The frequency of distribution of H. pylori did not differ throughout both the corpus and antrum greater and lesser curvature. However, the degree of H. pylori colonization in the corpus was higher in the lesser than in the greater curvature. The interobserver agreement was significantly higher for corpus atrophy compared to antrum atrophy. These findings demonstrated that the more severe atrophic, metaplastic and inflammatory changes were observed in the lesser compared to the greater curvature of the stomach. In routine clinical settings, corpus and antral biopsies should be obtained from both lesser and greater curvature. Analysis of the incisura biopsy is also important.

  20. Evaluation of registration accuracy between Sentinel-2 and Landsat 8

    NASA Astrophysics Data System (ADS)

    Barazzetti, Luigi; Cuca, Branka; Previtali, Mattia

    2016-08-01

    Starting from June 2015, Sentinel-2A is delivering high resolution optical images (ground resolution up to 10 meters) to provide a global coverage of the Earth's land surface every 10 days. The planned launch of Sentinel-2B along with the integration of Landsat images will provide time series with an unprecedented revisit time indispensable for numerous monitoring applications, in which high resolution multi-temporal information is required. They include agriculture, water bodies, natural hazards to name a few. However, the combined use of multi-temporal images requires an accurate geometric registration, i.e. pixel-to-pixel correspondence for terrain-corrected products. This paper presents an analysis of spatial co-registration accuracy for several datasets of Sentinel-2 and Landsat 8 images distributed all around the world. Images were compared with digital correlation techniques for image matching, obtaining an evaluation of registration accuracy with an affine transformation as geometrical model. Results demonstrate that sub-pixel accuracy was achieved between 10 m resolution Sentinel-2 bands (band 3) and 15 m resolution panchromatic Landsat images (band 8).

  1. Wind Prediction Accuracy for Air Traffic Management Decision Support Tools

    NASA Technical Reports Server (NTRS)

    Cole, Rod; Green, Steve; Jardin, Matt; Schwartz, Barry; Benjamin, Stan

    2000-01-01

    The performance of Air Traffic Management and flight deck decision support tools depends in large part on the accuracy of the supporting 4D trajectory predictions. This is particularly relevant to conflict prediction and active advisories for the resolution of conflicts and the conformance with of traffic-flow management flow-rate constraints (e.g., arrival metering / required time of arrival). Flight test results have indicated that wind prediction errors may represent the largest source of trajectory prediction error. The tests also discovered relatively large errors (e.g., greater than 20 knots), existing in pockets of space and time critical to ATM DST performance (one or more sectors, greater than 20 minutes), are inadequately represented by the classic RMS aggregate prediction-accuracy studies of the past. To facilitate the identification and reduction of DST-critical wind-prediction errors, NASA has lead a collaborative research and development activity with MIT Lincoln Laboratories and the Forecast Systems Lab of the National Oceanographic and Atmospheric Administration (NOAA). This activity, begun in 1996, has focussed on the development of key metrics for ATM DST performance, assessment of wind-prediction skill for state of the art systems, and development/validation of system enhancements to improve skill. A 13 month study was conducted for the Denver Center airspace in 1997. Two complementary wind-prediction systems were analyzed and compared to the forecast performance of the then standard 60 km Rapid Update Cycle - version 1 (RUC-1). One system, developed by NOAA, was the prototype 40-km RUC-2 that became operational at NCEP in 1999. RUC-2 introduced a faster cycle (1 hr vs. 3 hr) and improved mesoscale physics. The second system, Augmented Winds (AW), is a prototype en route wind application developed by MITLL based on the Integrated Terminal Wind System (ITWS). AW is run at a local facility (Center) level, and updates RUC predictions based on an

  2. Accuracy of maximum likelihood estimates of a two-state model in single-molecule FRET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gopich, Irina V.

    2015-01-21

    Photon sequences from single-molecule Förster resonance energy transfer (FRET) experiments can be analyzed using a maximum likelihood method. Parameters of the underlying kinetic model (FRET efficiencies of the states and transition rates between conformational states) are obtained by maximizing the appropriate likelihood function. In addition, the errors (uncertainties) of the extracted parameters can be obtained from the curvature of the likelihood function at the maximum. We study the standard deviations of the parameters of a two-state model obtained from photon sequences with recorded colors and arrival times. The standard deviations can be obtained analytically in a special case when themore » FRET efficiencies of the states are 0 and 1 and in the limiting cases of fast and slow conformational dynamics. These results are compared with the results of numerical simulations. The accuracy and, therefore, the ability to predict model parameters depend on how fast the transition rates are compared to the photon count rate. In the limit of slow transitions, the key parameters that determine the accuracy are the number of transitions between the states and the number of independent photon sequences. In the fast transition limit, the accuracy is determined by the small fraction of photons that are correlated with their neighbors. The relative standard deviation of the relaxation rate has a “chevron” shape as a function of the transition rate in the log-log scale. The location of the minimum of this function dramatically depends on how well the FRET efficiencies of the states are separated.« less

  3. Accuracy of maximum likelihood estimates of a two-state model in single-molecule FRET

    PubMed Central

    Gopich, Irina V.

    2015-01-01

    Photon sequences from single-molecule Förster resonance energy transfer (FRET) experiments can be analyzed using a maximum likelihood method. Parameters of the underlying kinetic model (FRET efficiencies of the states and transition rates between conformational states) are obtained by maximizing the appropriate likelihood function. In addition, the errors (uncertainties) of the extracted parameters can be obtained from the curvature of the likelihood function at the maximum. We study the standard deviations of the parameters of a two-state model obtained from photon sequences with recorded colors and arrival times. The standard deviations can be obtained analytically in a special case when the FRET efficiencies of the states are 0 and 1 and in the limiting cases of fast and slow conformational dynamics. These results are compared with the results of numerical simulations. The accuracy and, therefore, the ability to predict model parameters depend on how fast the transition rates are compared to the photon count rate. In the limit of slow transitions, the key parameters that determine the accuracy are the number of transitions between the states and the number of independent photon sequences. In the fast transition limit, the accuracy is determined by the small fraction of photons that are correlated with their neighbors. The relative standard deviation of the relaxation rate has a “chevron” shape as a function of the transition rate in the log-log scale. The location of the minimum of this function dramatically depends on how well the FRET efficiencies of the states are separated. PMID:25612692

  4. Development and evaluation of a Kalman-filter algorithm for terminal area navigation using sensors of moderate accuracy

    NASA Technical Reports Server (NTRS)

    Kanning, G.; Cicolani, L. S.; Schmidt, S. F.

    1983-01-01

    Translational state estimation in terminal area operations, using a set of commonly available position, air data, and acceleration sensors, is described. Kalman filtering is applied to obtain maximum estimation accuracy from the sensors but feasibility in real-time computations requires a variety of approximations and devices aimed at minimizing the required computation time with only negligible loss of accuracy. Accuracy behavior throughout the terminal area, its relation to sensor accuracy, its effect on trajectory tracking errors and control activity in an automatic flight control system, and its adequacy in terms of existing criteria for various terminal area operations are examined. The principal investigative tool is a simulation of the system.

  5. Predictive accuracy of combined genetic and environmental risk scores.

    PubMed

    Dudbridge, Frank; Pashayan, Nora; Yang, Jian

    2018-02-01

    The substantial heritability of most complex diseases suggests that genetic data could provide useful risk prediction. To date the performance of genetic risk scores has fallen short of the potential implied by heritability, but this can be explained by insufficient sample sizes for estimating highly polygenic models. When risk predictors already exist based on environment or lifestyle, two key questions are to what extent can they be improved by adding genetic information, and what is the ultimate potential of combined genetic and environmental risk scores? Here, we extend previous work on the predictive accuracy of polygenic scores to allow for an environmental score that may be correlated with the polygenic score, for example when the environmental factors mediate the genetic risk. We derive common measures of predictive accuracy and improvement as functions of the training sample size, chip heritabilities of disease and environmental score, and genetic correlation between disease and environmental risk factors. We consider simple addition of the two scores and a weighted sum that accounts for their correlation. Using examples from studies of cardiovascular disease and breast cancer, we show that improvements in discrimination are generally small but reasonable degrees of reclassification could be obtained with current sample sizes. Correlation between genetic and environmental scores has only minor effects on numerical results in realistic scenarios. In the longer term, as the accuracy of polygenic scores improves they will come to dominate the predictive accuracy compared to environmental scores. © 2017 WILEY PERIODICALS, INC.

  6. Predictive accuracy of combined genetic and environmental risk scores

    PubMed Central

    Pashayan, Nora; Yang, Jian

    2017-01-01

    ABSTRACT The substantial heritability of most complex diseases suggests that genetic data could provide useful risk prediction. To date the performance of genetic risk scores has fallen short of the potential implied by heritability, but this can be explained by insufficient sample sizes for estimating highly polygenic models. When risk predictors already exist based on environment or lifestyle, two key questions are to what extent can they be improved by adding genetic information, and what is the ultimate potential of combined genetic and environmental risk scores? Here, we extend previous work on the predictive accuracy of polygenic scores to allow for an environmental score that may be correlated with the polygenic score, for example when the environmental factors mediate the genetic risk. We derive common measures of predictive accuracy and improvement as functions of the training sample size, chip heritabilities of disease and environmental score, and genetic correlation between disease and environmental risk factors. We consider simple addition of the two scores and a weighted sum that accounts for their correlation. Using examples from studies of cardiovascular disease and breast cancer, we show that improvements in discrimination are generally small but reasonable degrees of reclassification could be obtained with current sample sizes. Correlation between genetic and environmental scores has only minor effects on numerical results in realistic scenarios. In the longer term, as the accuracy of polygenic scores improves they will come to dominate the predictive accuracy compared to environmental scores. PMID:29178508

  7. Greater India

    NASA Astrophysics Data System (ADS)

    Ali, Jason R.; Aitchison, Jonathan C.

    2005-10-01

    "Greater India" is an 80-yr-old concept that has been used by geoscientists in plate tectonic models of the India-Asia collision system. Numerous authors working on the orogen and/or plate models of the broader region have added various sized chunks of continental lithosphere to the now northern edge of their reconstructed Indian plate. Prior to plate tectonic theory, Emile Argand (1924) [Argand, E., 1924. La tectonique de l' Asie. Proc. 13th Int. Geol. Cong. 7 (1924), 171-372.] and Arthur Holmes (1965) [Holmes, A., 1965. Principles of Physical Geology, Second Edition. The Ronald Press Company, New York, 1128.] thought that the Himalayan Mountains and Tibetan Plateau had been raised due to the northern edge of the Indian craton under-thrusting the entire region. Since the advent of plate tectonic theory, Greater India proposals have been based principally on three lines of logic. One group of workers has added various amounts of continental lithosphere to India as part of their Mesozoic Gondwana models. A second form of reconstruction is based on Himalayan crustal-shortening estimates. A third body of researchers has used India continent extensions as means of allowing initial contact between the block and the Eurasian backstop plate in southern Tibet to take place at various times between the Late Cretaceous and late Eocene in what we call "fill-the-gap" solutions. The Indian craton and the southern edge of Eurasia were almost invariably some distance from one another when the collision was supposed to have started; extensions to the sub-continent were used to circumvent the problem. Occasionally, Greater India extensions have been based on a combination of fill-the-gap and shortening estimate arguments. In this paper, we exhume and re-examine the key Greater India proposals. From our analysis, it is clear that many proponents have ignored key information regarding the sub-continent's pre break-up position within Gondwana and the bathymetry of the Indian Ocean

  8. Effectiveness of Prompts on Fourth-Grade Children's Dietary Recall Accuracy Depends on Retention Interval and Varies by Gender.

    PubMed

    Baxter, Suzanne D; Smith, Albert F; Hitchcock, David B; Guinn, Caroline H; Royer, Julie A; Collins, Kathleen L; Smith, Alyssa L; Puryear, Megan P; Vaadi, Kate K; Finney, Christopher J; Miller, Patricia H

    2015-09-01

    Dietary recall accuracy is related to retention interval (RI) (i.e., time between to-be-reported meals and the interview), and possibly to prompts. To the best of our knowledge, no study has evaluated their combined effect. The combined influence of RI and prompts on children's recall accuracy was investigated in this study. Two RIs [short (prior-24-h recall obtained in afternoon) and long (previous-day recall obtained in morning)] were crossed with 4 prompts [forward (distant-to-recent), meal-name (breakfast, lunch, etc.), open (no instructions), and reverse (recent-to-distant)], creating 8 conditions. Fourth-grade children (n = 480; 50% girls) were randomly selected from consenting children at 10 schools in 4 districts in a southern state during 3 school years (2011-2012, 2012-2013, and 2013-2014). Each child was observed eating school-provided breakfast and lunch, and interviewed one time under 1 of the 8 conditions. Condition assignment was constrained so that each had 60 children (30 girls). Accuracy measures were food-item omission and intrusion rates, and energy correspondence rate and inflation ratio. For each measure, linear models determined effects of RI, prompt, gender, and interactions (2-way, 3-way); race/ethnicity, school year, and district were control variables. RI (P values < 0.015) and prompt (P values < 0.005) were significant for all 4 accuracy measures. RI × prompt (P values < 0.001) was significant for 3 accuracy measures (not intrusion rate). Prompt × gender (P = 0.005) was significant for omission rate. RI × prompt × gender was significant for intrusion rate and inflation ratio (P values < 0.001). For the short vs. long RI across prompts and genders, accuracy was better by 33-50% for each accuracy measure. To obtain the most accurate recalls possible from children, studies should be designed to use a short rather than long RI. Prompts affect children's recall accuracy, although the effectiveness of different prompts depends on RI and

  9. Accuracy concerns in digital speckle photography combined with Fresnel digital holographic interferometry

    NASA Astrophysics Data System (ADS)

    Zhao, Yuchen; Zemmamouche, Redouane; Vandenrijt, Jean-François; Georges, Marc P.

    2018-05-01

    A combination of digital holographic interferometry (DHI) and digital speckle photography (DSP) allows in-plane and out-of-plane displacement measurement between two states of an object. The former can be determined by correlating the two speckle patterns whereas the latter is given by the phase difference obtained from DHI. We show that the amplitude of numerically reconstructed object wavefront obtained from Fresnel in-line digital holography (DH), in combination with phase shifting techniques, can be used as speckle patterns in DSP. The accuracy of in-plane measurement is improved after correcting the phase errors induced by reference wave during reconstruction process. Furthermore, unlike conventional imaging system, Fresnel DH offers the possibility to resize the pixel size of speckle patterns situated on the reconstruction plane under the same optical configuration simply by zero-padding the hologram. The flexibility of speckle size adjustment in Fresnel DH ensures the accuracy of estimation result using DSP.

  10. High-accuracy direct aerial platform orientation with tightly coupled GPS/INS system : executive summary.

    DOT National Transportation Integrated Search

    2004-09-01

    Obtaining sensor orientation by direct measurements is : a rapidly emerging mapping technology. Modern GPS : and INS systems allow for the direct determination of : platform position and orientation at an unprecedented : accuracy. In airborne surveyi...

  11. Effects of sample survey design on the accuracy of classification tree models in species distribution models

    USGS Publications Warehouse

    Edwards, T.C.; Cutler, D.R.; Zimmermann, N.E.; Geiser, L.; Moisen, Gretchen G.

    2006-01-01

    We evaluated the effects of probabilistic (hereafter DESIGN) and non-probabilistic (PURPOSIVE) sample surveys on resultant classification tree models for predicting the presence of four lichen species in the Pacific Northwest, USA. Models derived from both survey forms were assessed using an independent data set (EVALUATION). Measures of accuracy as gauged by resubstitution rates were similar for each lichen species irrespective of the underlying sample survey form. Cross-validation estimates of prediction accuracies were lower than resubstitution accuracies for all species and both design types, and in all cases were closer to the true prediction accuracies based on the EVALUATION data set. We argue that greater emphasis should be placed on calculating and reporting cross-validation accuracy rates rather than simple resubstitution accuracy rates. Evaluation of the DESIGN and PURPOSIVE tree models on the EVALUATION data set shows significantly lower prediction accuracy for the PURPOSIVE tree models relative to the DESIGN models, indicating that non-probabilistic sample surveys may generate models with limited predictive capability. These differences were consistent across all four lichen species, with 11 of the 12 possible species and sample survey type comparisons having significantly lower accuracy rates. Some differences in accuracy were as large as 50%. The classification tree structures also differed considerably both among and within the modelled species, depending on the sample survey form. Overlap in the predictor variables selected by the DESIGN and PURPOSIVE tree models ranged from only 20% to 38%, indicating the classification trees fit the two evaluated survey forms on different sets of predictor variables. The magnitude of these differences in predictor variables throws doubt on ecological interpretation derived from prediction models based on non-probabilistic sample surveys. ?? 2006 Elsevier B.V. All rights reserved.

  12. [Assessment of precision and accuracy of digital surface photogrammetry with the DSP 400 system].

    PubMed

    Krimmel, M; Kluba, S; Dietz, K; Reinert, S

    2005-03-01

    The objective of the present study was to evaluate the precision and accuracy of facial anthropometric measurements obtained through digital 3-D surface photogrammetry with the DSP 400 system in comparison to traditional 2-D photogrammetry. Fifty plaster casts of cleft infants were imaged and 21 standard anthropometric measurements were obtained. For precision assessment the measurements were performed twice in a subsample. Accuracy was determined by comparison of direct measurements and indirect 2-D and 3-D image measurements. Precision of digital surface photogrammetry was almost as good as direct anthropometry and clearly better than 2-D photogrammetry. Measurements derived from 3-D images showed better congruence to direct measurements than from 2-D photos. Digital surface photogrammetry with the DSP 400 system is sufficiently precise and accurate for craniofacial anthropometric examinations.

  13. Evaluation of TDRSS-user orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Hodjatzadeh, M.; Samii, M. V.; Doll, C. E.; Hart, R. C.; Mistretta, G. D.

    1991-01-01

    The development of the Real-Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination on a Disk Operating System (DOS) based Personal Computer (PC) is addressed. The results of a study to compare the orbit determination accuracy of a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOD/E with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), is addressed. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for the Earth Radiation Budget Satellite (ERBS); the maximum solution differences were less than 25 m after the filter had reached steady state.

  14. Feasibility and accuracy of nasal alar pulse oximetry.

    PubMed

    Morey, T E; Rice, M J; Vasilopoulos, T; Dennis, D M; Melker, R J

    2014-06-01

    The nasal ala is an attractive site for pulse oximetry because of perfusion by branches of the external and internal carotid arteries. We evaluated the accuracy of a novel pulse oximetry sensor custom designed for the nasal ala. After IRB approval, healthy non-smoking subjects [n=12; aged 28 (23-41) yr; 6M/6F] breathed hypoxic mixtures of fresh gas by a facemask to achieve oxyhaemoglobin saturations of 70-100% measured by traditional co-oximetry from radial artery samples. Concurrent alar and finger pulse oximetry values were measured using probes designed for these sites. Data were analysed using the Bland-Altman method for multiple observations per subject. Bias, precision, and accuracy root mean square error (ARMS) over a range of 70-100% were significantly better for the alar probe compared with a standard finger probe. The mean bias for the alar and finger probes was 0.73% and 1.90% (P<0.001), respectively, with corresponding precision values of 1.65 and 1.83 (P=0.015) and ARMS values of 1.78% and 2.72% (P=0.047). The coefficients of determination were 0.96 and 0.96 for the alar and finger probes, respectively. The within/between-subject variation for the alar and finger probes were 1.14/1.57% and 1.87/1.47%, respectively. The limits of agreement were 3.96/-2.50% and 5.48/-1.68% for the alar and finger probes, respectively. Nasal alar pulse oximetry is feasible and demonstrates accurate pulse oximetry values over a range of 70-100%. The alar probe demonstrated greater accuracy compared with a conventional finger pulse oximeter. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Continuous Glucose Monitoring and Trend Accuracy

    PubMed Central

    Gottlieb, Rebecca; Le Compte, Aaron; Chase, J. Geoffrey

    2014-01-01

    Continuous glucose monitoring (CGM) devices are being increasingly used to monitor glycemia in people with diabetes. One advantage with CGM is the ability to monitor the trend of sensor glucose (SG) over time. However, there are few metrics available for assessing the trend accuracy of CGM devices. The aim of this study was to develop an easy to interpret tool for assessing trend accuracy of CGM data. SG data from CGM were compared to hourly blood glucose (BG) measurements and trend accuracy was quantified using the dot product. Trend accuracy results are displayed on the Trend Compass, which depicts trend accuracy as a function of BG. A trend performance table and Trend Index (TI) metric are also proposed. The Trend Compass was tested using simulated CGM data with varying levels of error and variability, as well as real clinical CGM data. The results show that the Trend Compass is an effective tool for differentiating good trend accuracy from poor trend accuracy, independent of glycemic variability. Furthermore, the real clinical data show that the Trend Compass assesses trend accuracy independent of point bias error. Finally, the importance of assessing trend accuracy as a function of BG level is highlighted in a case example of low and falling BG data, with corresponding rising SG data. This study developed a simple to use tool for quantifying trend accuracy. The resulting trend accuracy is easily interpreted on the Trend Compass plot, and if required, performance table and TI metric. PMID:24876437

  16. Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.

    PubMed

    Atieh, Mohammad A; Ritter, André V; Ko, Ching-Chang; Duqum, Ibrahim

    2017-09-01

    Trueness and precision are used to evaluate the accuracy of intraoral optical impressions. Although the in vivo precision of intraoral optical impressions has been reported, in vivo trueness has not been evaluated because of limitations in the available protocols. The purpose of this clinical study was to compare the accuracy (trueness and precision) of optical and conventional impressions by using a novel study design. Five study participants consented and were enrolled. For each participant, optical and conventional (vinylsiloxanether) impressions of a custom-made intraoral Co-Cr alloy reference appliance fitted to the mandibular arch were obtained by 1 operator. Three-dimensional (3D) digital models were created for stone casts obtained from the conventional impression group and for the reference appliances by using a validated high-accuracy reference scanner. For the optical impression group, 3D digital models were obtained directly from the intraoral scans. The total mean trueness of each impression system was calculated by averaging the mean absolute deviations of the impression replicates from their 3D reference model for each participant, followed by averaging the obtained values across all participants. The total mean precision for each impression system was calculated by averaging the mean absolute deviations between all the impression replicas for each participant (10 pairs), followed by averaging the obtained values across all participants. Data were analyzed using repeated measures ANOVA (α=.05), first to assess whether a systematic difference in trueness or precision of replicate impressions could be found among participants and second to assess whether the mean trueness and precision values differed between the 2 impression systems. Statistically significant differences were found between the 2 impression systems for both mean trueness (P=.010) and mean precision (P=.007). Conventional impressions had higher accuracy with a mean trueness of 17.0

  17. Trait Perception Accuracy and Acquaintance Within Groups: Tracking Accuracy Development.

    PubMed

    Brown, Jill A; Bernieri, Frank

    2017-05-01

    Previous work on trait perception has evaluated accuracy at discrete stages of relationships (e.g., strangers, best friends). A relatively limited body of literature has investigated changes in accuracy as acquaintance within a dyad or group increases. Small groups of initially unacquainted individuals spent more than 30 hr participating in a wide range of activities designed to represent common interpersonal contexts (e.g., eating, traveling). We calculated how accurately each participant judged others in their group on the big five traits across three distinct points within the acquaintance process: zero acquaintance, after a getting-to-know-you conversation, and after 10 weeks of interaction and activity. Judgments of all five traits exhibited accuracy above chance levels after 10 weeks. An examination of the trait rating stability revealed that much of the revision in judgments occurred not over the course of the 10-week relationship as suspected, but between zero acquaintance and the getting-to-know-you conversation.

  18. Accuracy of simple biochemical tests in identifying liver fibrosis in patients co-infected with human immunodeficiency virus and hepatitis C virus.

    PubMed

    Tural, Cristina; Tor, Jordi; Sanvisens, Arantza; Pérez-Alvarez, Núria; Martínez, Elisenda; Ojanguren, Isabel; García-Samaniego, Javier; Rockstroh, Juergen; Barluenga, Eva; Muga, Robert; Planas, Ramon; Sirera, Guillem; Rey-Joly, Celestino; Clotet, Bonaventura

    2009-03-01

    We assessed the ability of 3 simple biochemical tests to stage liver fibrosis in patients co-infected with human immunodeficiency virus (HIV) and hepatitis C virus (HCV). We analyzed liver biopsy samples from 324 consecutive HIV/HCV-positive patients (72% men; mean age, 38 y; mean CD4+ T-cell counts, 548 cells/mm(3)). Scheuer fibrosis scores were as follows: 30% had F0, 22% had F1, 19% had F2, 23% had F3, and 6% had F4. Logistic regression analyses were used to predict the probability of significant (>or=F2) or advanced (>or=F3) fibrosis, based on numeric scores from the APRI, FORNS, or FIB-4 tests (alone and in combination). Area under the receiver operating characteristic curves were analyzed to assess diagnostic performance. Area under the receiver operating characteristic curves analyses indicated that the 3 tests had similar abilities to identify F2 and F3; the ability of APRI, FORNS, and FIB-4 were as follows: F2 or greater: 0.72, 0.67, and 0.72, respectively; F3 or greater: 0.75, 0.73, and 0.78, respectively. The accuracy of each test in predicting which samples were F3 or greater was significantly higher than for F2 or greater (APRI, FORNS, and FIB-4: >or=F3: 75%, 76%, and 76%, respectively; >or=F2: 66%, 62%, and 68%, respectively). By using the lowest cut-off values for all 3 tests, F3 or greater was ruled out with sensitivity and negative predictive values of 79% to 94% and 87% to 91%, respectively, and 47% to 70% accuracy. Advanced liver fibrosis (>or=F3) was identified using the highest cut-off value, with specificity and positive predictive values of 90% to 96% and 63% to 73%, respectively, and 75% to 77% accuracy. Simple biochemical tests accurately predicted liver fibrosis in more than half the HIV/HCV co-infected patients. The absence and presence of liver fibrosis are predicted fairly using the lowest and highest cut-off levels, respectively.

  19. Evaluation of LiDAR-acquired bathymetric and topographic data accuracy in various hydrogeomorphic settings in the Deadwood and South Fork Boise Rivers, West-Central Idaho, 2007

    USGS Publications Warehouse

    Skinner, Kenneth D.

    2011-01-01

    High-quality elevation data in riverine environments are important for fisheries management applications and the accuracy of such data needs to be determined for its proper application. The Experimental Advanced Airborne Research LiDAR (Light Detection and Ranging)-or EAARL-system was used to obtain topographic and bathymetric data along the Deadwood and South Fork Boise Rivers in west-central Idaho. The EAARL data were post-processed into bare earth and bathymetric raster and point datasets. Concurrently with the EAARL surveys, real-time kinematic global positioning system surveys were made in three areas along each of the rivers to assess the accuracy of the EAARL elevation data in different hydrogeomorphic settings. The accuracies of the EAARL-derived raster elevation values, determined in open, flat terrain, to provide an optimal vertical comparison surface, had root mean square errors ranging from 0.134 to 0.347 m. Accuracies in the elevation values for the stream hydrogeomorphic settings had root mean square errors ranging from 0.251 to 0.782 m. The greater root mean square errors for the latter data are the result of complex hydrogeomorphic environments within the streams, such as submerged aquatic macrophytes and air bubble entrainment; and those along the banks, such as boulders, woody debris, and steep slopes. These complex environments reduce the accuracy of EAARL bathymetric and topographic measurements. Steep banks emphasize the horizontal location discrepancies between the EAARL and ground-survey data and may not be good representations of vertical accuracy. The EAARL point to ground-survey comparisons produced results with slightly higher but similar root mean square errors than those for the EAARL raster to ground-survey comparisons, emphasizing the minimized horizontal offset by using interpolated values from the raster dataset at the exact location of the ground-survey point as opposed to an actual EAARL point within a 1-meter distance. The

  20. Larger core size has superior technical and analytical accuracy in bladder tissue microarray.

    PubMed

    Eskaros, Adel Rh; Egloff, Shanna A Arnold; Boyd, Kelli L; Richardson, Joyce E; Hyndman, M Eric; Zijlstra, Andries

    2017-03-01

    The construction of tissue microarrays (TMAs) with cores from a large number of paraffin-embedded tissues (donors) into a single paraffin block (recipient) is an effective method of analyzing samples from many patient specimens simultaneously. For the TMA to be successful, the cores within it must capture the correct histologic areas from the donor blocks (technical accuracy) and maintain concordance with the tissue of origin (analytical accuracy). This can be particularly challenging for tissues with small histological features such as small islands of carcinoma in situ (CIS), thin layers of normal urothelial lining of the bladder, or cancers that exhibit intratumor heterogeneity. In an effort to create a comprehensive TMA of a bladder cancer patient cohort that accurately represents the tumor heterogeneity and captures the small features of normal and CIS, we determined how core size (0.6 vs 1.0 mm) impacted the technical and analytical accuracy of the TMA. The larger 1.0 mm core exhibited better technical accuracy for all tissue types at 80.9% (normal), 94.2% (tumor), and 71.4% (CIS) compared with 58.6%, 85.9%, and 63.8% for 0.6 mm cores. Although the 1.0 mm core provided better tissue capture, increasing the number of replicates from two to three allowed with the 0.6 mm core compensated for this reduced technical accuracy. However, quantitative image analysis of proliferation using both Ki67+ immunofluorescence counts and manual mitotic counts demonstrated that the 1.0 mm core size also exhibited significantly greater analytical accuracy (P=0.004 and 0.035, respectively, r 2 =0.979 and 0.669, respectively). Ultimately, our findings demonstrate that capturing two or more 1.0 mm cores for TMA construction provides superior technical and analytical accuracy over the smaller 0.6 mm cores, especially for tissues harboring small histological features or substantial heterogeneity.

  1. Diagnostic accuracy of imaging devices in glaucoma: A meta-analysis.

    PubMed

    Fallon, Monica; Valero, Oliver; Pazos, Marta; Antón, Alfonso

    Imaging devices such as the Heidelberg retinal tomograph-3 (HRT3), scanning laser polarimetry (GDx), and optical coherence tomography (OCT) play an important role in glaucoma diagnosis. A systematic search for evidence-based data was performed for prospective studies evaluating the diagnostic accuracy of HRT3, GDx, and OCT. The diagnostic odds ratio (DOR) was calculated. To compare the accuracy among instruments and parameters, a meta-analysis considering the hierarchical summary receiver-operating characteristic model was performed. The risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Studies in the context of screening programs were used for qualitative analysis. Eighty-six articles were included. The DOR values were 29.5 for OCT, 18.6 for GDx, and 13.9 for HRT. The heterogeneity analysis demonstrated statistically a significant influence of degree of damage and ethnicity. Studies analyzing patients with earlier glaucoma showed poorer results. The risk of bias was high for patient selection. Screening studies showed lower sensitivity values and similar specificity values when compared with those included in the meta-analysis. The classification capabilities of GDx, HRT, and OCT were high and similar across the 3 instruments. The highest estimated DOR was obtained with OCT. Diagnostic accuracy could be overestimated in studies including prediagnosed groups of subjects. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Accuracy in Blood Glucose Measurement: What Will a Tightening of Requirements Yield?

    PubMed Central

    Heinemann, Lutz; Lodwig, Volker; Freckmann, Guido

    2012-01-01

    Nowadays, almost all persons with diabetes—at least those using antidiabetic drug therapy—use one of a plethora of meters commercially available for self-monitoring of blood glucose. The accuracy of blood glucose (BG) measurement using these meters has been presumed to be adequate; that is, the accuracy of these devices was not usually questioned until recently. Health authorities in the United States (Food and Drug Administration) and in other countries are currently endeavoring to tighten the requirements for the accuracy of these meters above the level that is currently stated in the standard ISO 15197. At first glance, this does not appear to be a problem and is hardly worth further consideration, but a closer look reveals a considerable range of critical aspects that will be discussed in this commentary. In summary, one could say that as a result of modern production methods and ongoing technical advances, the demands placed on the quality of measurement results obtained with BG meters can be increased to a certain degree. One should also take into consideration that the system accuracy (which covers many more aspects as the analytical accuracy) required to make correct therapeutical decisions certainly varies for different types of therapy. At the end, in addition to analytical accuracy, thorough and systematic training of patients and regular refresher training is important to minimize errors. Only under such circumstances will patients make appropriate therapeutic interventions to optimize and maintain metabolic control. PMID:22538158

  3. Factors affecting the accuracy of genomic selection for growth and wood quality traits in an advanced-breeding population of black spruce (Picea mariana).

    PubMed

    Lenz, Patrick R N; Beaulieu, Jean; Mansfield, Shawn D; Clément, Sébastien; Desponts, Mireille; Bousquet, Jean

    2017-04-28

    Genomic selection (GS) uses information from genomic signatures consisting of thousands of genetic markers to predict complex traits. As such, GS represents a promising approach to accelerate tree breeding, which is especially relevant for the genetic improvement of boreal conifers characterized by long breeding cycles. In the present study, we tested GS in an advanced-breeding population of the boreal black spruce (Picea mariana [Mill.] BSP) for growth and wood quality traits, and concurrently examined factors affecting GS model accuracy. The study relied on 734 25-year-old trees belonging to 34 full-sib families derived from 27 parents and that were established on two contrasting sites. Genomic profiles were obtained from 4993 Single Nucleotide Polymorphisms (SNPs) representative of as many gene loci distributed among the 12 linkage groups common to spruce. GS models were obtained for four growth and wood traits. Validation using independent sets of trees showed that GS model accuracy was high, related to trait heritability and equivalent to that of conventional pedigree-based models. In forward selection, gains per unit of time were three times higher with the GS approach than with conventional selection. In addition, models were also accurate across sites, indicating little genotype-by-environment interaction in the area investigated. Using information from half-sibs instead of full-sibs led to a significant reduction in model accuracy, indicating that the inclusion of relatedness in the model contributed to its higher accuracies. About 500 to 1000 markers were sufficient to obtain GS model accuracy almost equivalent to that obtained with all markers, whether they were well spread across the genome or from a single linkage group, further confirming the implication of relatedness and potential long-range linkage disequilibrium (LD) in the high accuracy estimates obtained. Only slightly higher model accuracy was obtained when using marker subsets that were

  4. The Social Accuracy Model of Interpersonal Perception: Assessing Individual Differences in Perceptive and Expressive Accuracy

    ERIC Educational Resources Information Center

    Biesanz, Jeremy C.

    2010-01-01

    The social accuracy model of interpersonal perception (SAM) is a componential model that estimates perceiver and target effects of different components of accuracy across traits simultaneously. For instance, Jane may be generally accurate in her perceptions of others and thus high in "perceptive accuracy"--the extent to which a particular…

  5. Linear-scaling time-dependent density-functional theory beyond the Tamm-Dancoff approximation: Obtaining efficiency and accuracy with in situ optimised local orbitals.

    PubMed

    Zuehlsdorff, T J; Hine, N D M; Payne, M C; Haynes, P D

    2015-11-28

    We present a solution of the full time-dependent density-functional theory (TDDFT) eigenvalue equation in the linear response formalism exhibiting a linear-scaling computational complexity with system size, without relying on the simplifying Tamm-Dancoff approximation (TDA). The implementation relies on representing the occupied and unoccupied subspaces with two different sets of in situ optimised localised functions, yielding a very compact and efficient representation of the transition density matrix of the excitation with the accuracy associated with a systematic basis set. The TDDFT eigenvalue equation is solved using a preconditioned conjugate gradient algorithm that is very memory-efficient. The algorithm is validated on a small test molecule and a good agreement with results obtained from standard quantum chemistry packages is found, with the preconditioner yielding a significant improvement in convergence rates. The method developed in this work is then used to reproduce experimental results of the absorption spectrum of bacteriochlorophyll in an organic solvent, where it is demonstrated that the TDA fails to reproduce the main features of the low energy spectrum, while the full TDDFT equation yields results in good qualitative agreement with experimental data. Furthermore, the need for explicitly including parts of the solvent into the TDDFT calculations is highlighted, making the treatment of large system sizes necessary that are well within reach of the capabilities of the algorithm introduced here. Finally, the linear-scaling properties of the algorithm are demonstrated by computing the lowest excitation energy of bacteriochlorophyll in solution. The largest systems considered in this work are of the same order of magnitude as a variety of widely studied pigment-protein complexes, opening up the possibility of studying their properties without having to resort to any semiclassical approximations to parts of the protein environment.

  6. Linear-scaling time-dependent density-functional theory beyond the Tamm-Dancoff approximation: Obtaining efficiency and accuracy with in situ optimised local orbitals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zuehlsdorff, T. J., E-mail: tjz21@cam.ac.uk; Payne, M. C.; Hine, N. D. M.

    2015-11-28

    We present a solution of the full time-dependent density-functional theory (TDDFT) eigenvalue equation in the linear response formalism exhibiting a linear-scaling computational complexity with system size, without relying on the simplifying Tamm-Dancoff approximation (TDA). The implementation relies on representing the occupied and unoccupied subspaces with two different sets of in situ optimised localised functions, yielding a very compact and efficient representation of the transition density matrix of the excitation with the accuracy associated with a systematic basis set. The TDDFT eigenvalue equation is solved using a preconditioned conjugate gradient algorithm that is very memory-efficient. The algorithm is validated on amore » small test molecule and a good agreement with results obtained from standard quantum chemistry packages is found, with the preconditioner yielding a significant improvement in convergence rates. The method developed in this work is then used to reproduce experimental results of the absorption spectrum of bacteriochlorophyll in an organic solvent, where it is demonstrated that the TDA fails to reproduce the main features of the low energy spectrum, while the full TDDFT equation yields results in good qualitative agreement with experimental data. Furthermore, the need for explicitly including parts of the solvent into the TDDFT calculations is highlighted, making the treatment of large system sizes necessary that are well within reach of the capabilities of the algorithm introduced here. Finally, the linear-scaling properties of the algorithm are demonstrated by computing the lowest excitation energy of bacteriochlorophyll in solution. The largest systems considered in this work are of the same order of magnitude as a variety of widely studied pigment-protein complexes, opening up the possibility of studying their properties without having to resort to any semiclassical approximations to parts of the protein environment.« less

  7. Evaluation of LiDAR-Acquired Bathymetric and Topographic Data Accuracy in Various Hydrogeomorphic Settings in the Lower Boise River, Southwestern Idaho, 2007

    USGS Publications Warehouse

    Skinner, Kenneth D.

    2009-01-01

    Elevation data in riverine environments can be used in various applications for which different levels of accuracy are required. The Experimental Advanced Airborne Research LiDAR (Light Detection and Ranging) - or EAARL - system was used to obtain topographic and bathymetric data along the lower Boise River, southwestern Idaho, for use in hydraulic and habitat modeling. The EAARL data were post-processed into bare earth and bathymetric raster and point datasets. Concurrently with the EAARL data collection, real-time kinetic global positioning system and total station ground-survey data were collected in three areas within the lower Boise River basin to assess the accuracy of the EAARL elevation data in different hydrogeomorphic settings. The accuracies of the EAARL-derived elevation data, determined in open, flat terrain, to provide an optimal vertical comparison surface, had root mean square errors ranging from 0.082 to 0.138 m. Accuracies for bank, floodplain, and in-stream bathymetric data had root mean square errors ranging from 0.090 to 0.583 m. The greater root mean square errors for the latter data are the result of high levels of turbidity in the downstream ground-survey area, dense tree canopy, and horizontal location discrepancies between the EAARL and ground-survey data in steeply sloping areas such as riverbanks. The EAARL point to ground-survey comparisons produced results similar to those for the EAARL raster to ground-survey comparisons, indicating that the interpolation of the EAARL points to rasters did not introduce significant additional error. The mean percent error for the wetted cross-sectional areas of the two upstream ground-survey areas was 1 percent. The mean percent error increases to -18 percent if the downstream ground-survey area is included, reflecting the influence of turbidity in that area.

  8. Speed-Accuracy Response Models: Scoring Rules Based on Response Time and Accuracy

    ERIC Educational Resources Information Center

    Maris, Gunter; van der Maas, Han

    2012-01-01

    Starting from an explicit scoring rule for time limit tasks incorporating both response time and accuracy, and a definite trade-off between speed and accuracy, a response model is derived. Since the scoring rule is interpreted as a sufficient statistic, the model belongs to the exponential family. The various marginal and conditional distributions…

  9. Empirical evidence of the importance of comparative studies of diagnostic test accuracy.

    PubMed

    Takwoingi, Yemisi; Leeflang, Mariska M G; Deeks, Jonathan J

    2013-04-02

    Systematic reviews that "compare" the accuracy of 2 or more tests often include different sets of studies for each test. To investigate the availability of direct comparative studies of test accuracy and to assess whether summary estimates of accuracy differ between meta-analyses of noncomparative and comparative studies. Systematic reviews in any language from the Database of Abstracts of Reviews of Effects and the Cochrane Database of Systematic Reviews from 1994 to October 2012. 1 of 2 assessors selected reviews that evaluated at least 2 tests and identified meta-analyses that included both noncomparative studies and comparative studies. 1 of 3 assessors extracted data about review and study characteristics and test performance. 248 reviews compared test accuracy; of the 6915 studies, 2113 (31%) were comparative. Thirty-six reviews (with 52 meta-analyses) had adequate studies to compare results of noncomparative and comparative studies by using a hierarchical summary receiver-operating characteristic meta-regression model for each test comparison. In 10 meta-analyses, noncomparative studies ranked tests in the opposite order of comparative studies. A total of 25 meta-analyses showed more than a 2-fold discrepancy in the relative diagnostic odds ratio between noncomparative and comparative studies. Differences in accuracy estimates between noncomparative and comparative studies were greater than expected by chance (P < 0.001). A paucity of comparative studies limited exploration of direction in bias. Evidence derived from noncomparative studies often differs from that derived from comparative studies. Robustly designed studies in which all patients receive all tests or are randomly assigned to receive one or other of the tests should be more routinely undertaken and are preferred for evidence to guide test selection. National Institute for Health Research (United Kingdom).

  10. Accuracy Evaluation of the Unified P-Value from Combining Correlated P-Values

    PubMed Central

    Alves, Gelio; Yu, Yi-Kuo

    2014-01-01

    Meta-analysis methods that combine -values into a single unified -value are frequently employed to improve confidence in hypothesis testing. An assumption made by most meta-analysis methods is that the -values to be combined are independent, which may not always be true. To investigate the accuracy of the unified -value from combining correlated -values, we have evaluated a family of statistical methods that combine: independent, weighted independent, correlated, and weighted correlated -values. Statistical accuracy evaluation by combining simulated correlated -values showed that correlation among -values can have a significant effect on the accuracy of the combined -value obtained. Among the statistical methods evaluated those that weight -values compute more accurate combined -values than those that do not. Also, statistical methods that utilize the correlation information have the best performance, producing significantly more accurate combined -values. In our study we have demonstrated that statistical methods that combine -values based on the assumption of independence can produce inaccurate -values when combining correlated -values, even when the -values are only weakly correlated. Therefore, to prevent from drawing false conclusions during hypothesis testing, our study advises caution be used when interpreting the -value obtained from combining -values of unknown correlation. However, when the correlation information is available, the weighting-capable statistical method, first introduced by Brown and recently modified by Hou, seems to perform the best amongst the methods investigated. PMID:24663491

  11. Entropy of space-time outcome in a movement speed-accuracy task.

    PubMed

    Hsieh, Tsung-Yu; Pacheco, Matheus Maia; Newell, Karl M

    2015-12-01

    The experiment reported was set-up to investigate the space-time entropy of movement outcome as a function of a range of spatial (10, 20 and 30 cm) and temporal (250-2500 ms) criteria in a discrete aiming task. The variability and information entropy of the movement spatial and temporal errors considered separately increased and decreased on the respective dimension as a function of an increment of movement velocity. However, the joint space-time entropy was lowest when the relative contribution of spatial and temporal task criteria was comparable (i.e., mid-range of space-time constraints), and it increased with a greater trade-off between spatial or temporal task demands, revealing a U-shaped function across space-time task criteria. The traditional speed-accuracy functions of spatial error and temporal error considered independently mapped to this joint space-time U-shaped entropy function. The trade-off in movement tasks with joint space-time criteria is between spatial error and timing error, rather than movement speed and accuracy. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation.

    PubMed

    Erdogan Kayhan, Gulay; Colak, Yusuf Z; Sanli, Mukadder; Ucar, Muharrem; Toprak, Huseyin I

    2017-05-01

    Hemoglobin level monitoring is essential during liver transplantation (LT) due to substantial blood loss. We evaluated the accuracy of non-invasive and continuous hemoglobin monitoring (SpHb) obtained by a transcutaneous spectrophotometry-based technology (Masimo Corporation, Irvine, CA) compared with conventional laboratory Hb measurement (HbL) during LT. Additionally, we made subgroup analyses for distinct surgical phases that have special features and hemodynamic problems and thus may affect the accuracy of SpHb. During LT, blood samples were obtained twice for each of the three phases of LT (pre-anhepatic, anhepatic, and neohepatic) and were analyzed by the central laboratory. The HbL measurements were compared with SpHb obtained at the time of the blood draws. A total of 282 data pairs obtained from 53 patients were analyzed. The SpHb values ranged from 6.9 to 17.7 g/dL, and the HbL values ranged from 5.4 to 17.1 g/dL. The correlation coefficient between SpHb and HbL was 0.73 (P<0.001), and change in SpHb versus change in HbL was 0.76 (P<0.001). The sensitivity value determined using a 4-quadrant plot was 79%. The bias and precision of SpHb to HbL were 0.86±1.58 g/dL; the limits of agreement were -2.25 to 3.96 g/dL. The overall correlation between SpHb and HbL remained stable in different phases of surgical procedure. SpHb was demonstrated to have a clinically acceptable accuracy of hemoglobin measurement in comparison with a standard laboratory device when used during LT. This technology can be useful as a trend monitor during all surgical phases of LT and can supplement HbL to optimize transfusion decisions or to detect occult bleeding.

  13. Emotion Enhances the Subjective Feeling of Remembering, Despite Lower Accuracy for Contextual Details

    PubMed Central

    Rimmele, Ulrike; Davachi, Lila; Petrov, Radoslav; Dougal, Sonya; Phelps, Elizabeth A.

    2013-01-01

    Emotion strengthens the subjective experience of recollection. However, these vivid and confidently remembered emotional memories may not necessarily be more accurate. We investigated whether the subjective sense of recollection for negative stimuli is coupled with enhanced memory accuracy for contextual details using the remember/know paradigm. Our results indicate a double-dissociation between the subjective feeling of remembering, and the objective memory accuracy for details of negative and neutral scenes. “Remember” judgments were boosted for negative relative to neutral scenes. In contrast, memory for contextual details and associative binding was worse for negative compared to neutral scenes given a “remember” response. These findings show that the enhanced subjective recollective experience for negative stimuli does not reliably indicate greater objective recollection, at least of the details tested, and thus may be driven by a different mechanism than the subjective recollective experience for neutral stimuli. PMID:21668106

  14. Fundamental Importance of Reference Glucose Analyzer Accuracy for Evaluating the Performance of Blood Glucose Monitoring Systems (BGMSs).

    PubMed

    Bailey, Timothy S; Klaff, Leslie J; Wallace, Jane F; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A

    2016-07-01

    As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects' self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (-0.64% to -2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. © 2016 Diabetes Technology Society.

  15. The Accuracy Of Fuzzy Sugeno Method With Antropometry On Determination Natural Patient Status

    NASA Astrophysics Data System (ADS)

    Syahputra, Dinur; Tulus; Sawaluddin

    2017-12-01

    Anthropometry is one of the processes that can be used to assess nutritional status. In general anthropometry is defined as body size in terms of nutrition, then anthropometry is reviewed from various age levels and nutritional levels. Nutritional status is a description of the balance between nutritional intake with the needs of the body individually. Fuzzy logic is a logic that has a vagueness between right and wrong or between 0 and 1. Sugeno method is used because in the process of calculating nutritional status so far is still done by anthropometry. Currently information technology is growing in any aspect, one of them in the aspect of calculation with data taken from anthropometry. In this case the calculation can use the Fuzzy Sugeno Method, in order to know the great accuracy obtained. Then the results obtained using fuzzy sugeno integrated with anthropometry has an accuracy of 81.48%.

  16. Low accuracy and low consistency of fourth-graders' school breakfast and school lunch recalls

    PubMed Central

    THOMPSON, WILLIAM 0.; LITAKER, MARK S.; FRYE, FRANCESCA H.A.; GUINN, CAROLINE H.

    2005-01-01

    Objective To determine the accuracy and consistency of fourth-graders' school breakfast and school lunch recalls obtained during 24-hour recalls and compared with observed intake. Design Children were interviewed using a multiple-pass protocol at school the morning after being observed eating school breakfast and school lunch. Subjects 104 children stratified by ethnicity (African-American, white) and gender were randomly selected and interviewed up to 3 times each with 4 to 14 weeks between each interview. Statistical analysis Match, omission, and intrusion rates to determine accuracy of reporting items; arithmetic and/or absolute differences to determine accuracy for reporting amounts; total inaccuracy to determine inaccuracy for reporting items and amounts combined; intraclass correlation coefficients (ICC) to determine consistency. Results Means were 51% for omission rate, 39% for intrusion rate, and 7.1 servings for total inaccuracy. Total inaccuracy decreased significantly from the first to the third recall (P=0.006). The ICC was 0.29 for total inaccuracy and 0.15 for omission rate. For all meal components except bread/grain and beverage, there were more omissions than intrusions. Mean arithmetic and absolute differences per serving in amount reported for matches were -0.08 and 0.24, respectively. Mean amounts per serving of omissions and intrusions were 0.86 and 0.80, respectively. Applications/conclusions The low accuracy and low consistency of children's recalls from this study raise concerns regarding the current uses of dietary recalls obtained from children. To improve the accuracy and consistency of children's dietary recalls, validation studies are needed to determine the best way(s) to interview children. PMID:11905461

  17. Accuracy of the Velotron ergometer and SRM power meter.

    PubMed

    Abbiss, C R; Quod, M J; Levin, G; Martin, D T; Laursen, P B

    2009-02-01

    The purpose of this study was to determine the accuracy of the Velotron cycle ergometer and the SRM power meter using a dynamic calibration rig over a range of exercise protocols commonly applied in laboratory settings. These trials included two sustained constant power trials (250 W and 414 W), two incremental power trials and three high-intensity interval power trials. To further compare the two systems, 15 subjects performed three dynamic 30 km performance time trials. The Velotron and SRM displayed accurate measurements of power during both constant power trials (<1% error). However, during high-intensity interval trials the Velotron and SRM were found to be less accurate (3.0%, CI=1.6-4.5% and -2.6%, CI=-3.2--2.0% error, respectively). During the dynamic 30 km time trials, power measured by the Velotron was 3.7+/-1.9% (CI=2.9-4.8%) greater than that measured by the SRM. In conclusion, the accuracy of the Velotron cycle ergometer and the SRM power meter appears to be dependent on the type of test being performed. Furthermore, as each power monitoring system measures power at various positions (i.e. bottom bracket vs. rear wheel), caution should be taken when comparing power across the two systems, particularly when power is variable.

  18. Predicting Greater Prairie-Chicken Lek Site Suitability to Inform Conservation Actions

    PubMed Central

    Hovick, Torre J.; Dahlgren, David K.; Papeş, Monica; Elmore, R. Dwayne; Pitman, James C.

    2015-01-01

    The demands of a growing human population dictates that expansion of energy infrastructure, roads, and other development frequently takes place in native rangelands. Particularly, transmission lines and roads commonly divide rural landscapes and increase fragmentation. This has direct and indirect consequences on native wildlife that can be mitigated through thoughtful planning and proactive approaches to identifying areas of high conservation priority. We used nine years (2003–2011) of Greater Prairie-Chicken (Tympanuchus cupido) lek locations totaling 870 unique leks sites in Kansas and seven geographic information system (GIS) layers describing land cover, topography, and anthropogenic structures to model habitat suitability across the state. The models obtained had low omission rates (<0.18) and high area under the curve scores (AUC >0.81), indicating high model performance and reliability of predicted habitat suitability for Greater Prairie-Chickens. We found that elevation was the most influential in predicting lek locations, contributing three times more predictive power than any other variable. However, models were improved by the addition of land cover and anthropogenic features (transmission lines, roads, and oil and gas structures). Overall, our analysis provides a hierarchal understanding of Greater Prairie-Chicken habitat suitability that is broadly based on geomorphological features followed by land cover suitability. We found that when land features and vegetation cover are suitable for Greater Prairie-Chickens, fragmentation by anthropogenic sources such as roadways and transmission lines are a concern. Therefore, it is our recommendation that future human development in Kansas avoid areas that our models identified as highly suitable for Greater Prairie-Chickens and focus development on land cover types that are of lower conservation concern. PMID:26317349

  19. Predicting Greater Prairie-Chicken Lek Site Suitability to Inform Conservation Actions.

    PubMed

    Hovick, Torre J; Dahlgren, David K; Papeş, Monica; Elmore, R Dwayne; Pitman, James C

    2015-01-01

    The demands of a growing human population dictates that expansion of energy infrastructure, roads, and other development frequently takes place in native rangelands. Particularly, transmission lines and roads commonly divide rural landscapes and increase fragmentation. This has direct and indirect consequences on native wildlife that can be mitigated through thoughtful planning and proactive approaches to identifying areas of high conservation priority. We used nine years (2003-2011) of Greater Prairie-Chicken (Tympanuchus cupido) lek locations totaling 870 unique leks sites in Kansas and seven geographic information system (GIS) layers describing land cover, topography, and anthropogenic structures to model habitat suitability across the state. The models obtained had low omission rates (<0.18) and high area under the curve scores (AUC >0.81), indicating high model performance and reliability of predicted habitat suitability for Greater Prairie-Chickens. We found that elevation was the most influential in predicting lek locations, contributing three times more predictive power than any other variable. However, models were improved by the addition of land cover and anthropogenic features (transmission lines, roads, and oil and gas structures). Overall, our analysis provides a hierarchal understanding of Greater Prairie-Chicken habitat suitability that is broadly based on geomorphological features followed by land cover suitability. We found that when land features and vegetation cover are suitable for Greater Prairie-Chickens, fragmentation by anthropogenic sources such as roadways and transmission lines are a concern. Therefore, it is our recommendation that future human development in Kansas avoid areas that our models identified as highly suitable for Greater Prairie-Chickens and focus development on land cover types that are of lower conservation concern.

  20. QUADAS and STARD: evaluating the quality of diagnostic accuracy studies.

    PubMed

    Oliveira, Maria Regina Fernandes de; Gomes, Almério de Castro; Toscano, Cristiana Maria

    2011-04-01

    To compare the performance of two approaches, one based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and another on the Standards for Reporting Studies of Diagnostic Accuracy (STARD), in evaluating the quality of studies validating the OptiMal® rapid malaria diagnostic test. Articles validating the rapid test published until 2007 were searched in the Medline/PubMed database. This search retrieved 13 articles. A combination of 12 QUADAS criteria and three STARD criteria were compared with the 12 QUADAS criteria alone. Articles that fulfilled at least 50% of QUADAS criteria were considered as regular to good quality. Of the 13 articles retrieved, 12 fulfilled at least 50% of QUADAS criteria, and only two fulfilled the STARD/QUADAS criteria combined. Considering the two criteria combination (> 6 QUADAS and > 3 STARD), two studies (15.4%) showed good methodological quality. The articles selection using the proposed combination resulted in two to eight articles, depending on the number of items assumed as cutoff point. The STARD/QUADAS combination has the potential to provide greater rigor when evaluating the quality of studies validating malaria diagnostic tests, given that it incorporates relevant information not contemplated in the QUADAS criteria alone.

  1. Variance estimates and confidence intervals for the Kappa measure of classification accuracy

    Treesearch

    M. A. Kalkhan; R. M. Reich; R. L. Czaplewski

    1997-01-01

    The Kappa statistic is frequently used to characterize the results of an accuracy assessment used to evaluate land use and land cover classifications obtained by remotely sensed data. This statistic allows comparisons of alternative sampling designs, classification algorithms, photo-interpreters, and so forth. In order to make these comparisons, it is...

  2. College of American Pathologists Cancer Protocols: Optimizing Format for Accuracy and Efficiency.

    PubMed

    Strickland-Marmol, Leah B; Muro-Cacho, Carlos A; Barnett, Scott D; Banas, Matthew R; Foulis, Philip R

    2016-06-01

    -The data in College of American Pathologists cancer protocols have to be presented effectively to health care providers. There is no consensus on the format of those protocols, resulting in various designs among pathologists. Cancer protocols are independently created by site-specific experts, so there is inconsistent wording and repetition of data. This lack of standardization can be confusing and may lead to interpretation errors. -To define a synopsis format that is effective in delivering essential pathologic information and to evaluate the aesthetic appeal and the impact of varying format styles on the speed and accuracy of data extraction. -We queried individuals from several health care backgrounds using varying formats of the fallopian tube protocol of the College of American Pathologists without content modification to investigate their aesthetic appeal, accuracy, efficiency, and readability/complexity. Descriptive statistics, an item difficulty index, and 3 tests of readability were used. -Columned formats were aesthetically more appealing than justified formats (P < .001) and were associated with greater accuracy and efficiency. Incorrect assumptions were made about items not included in the protocol. Uniform wording and short sentences were associated with better performance by participants. -Based on these data, we propose standardized protocol formats for cancer resections of the fallopian tube and the more-familiar colon, employing headers, short phrases, and uniform terminology. This template can be easily and minimally modified for other sites, standardizing format and verbiage and increasing user accuracy and efficiency. Principles of human factors engineering should be considered in the display of patient data.

  3. Dual-source CT imaging to plan transcatheter aortic valve replacement: accuracy for diagnosis of obstructive coronary artery disease.

    PubMed

    Harris, Brett S; De Cecco, Carlo N; Schoepf, U Joseph; Steinberg, Daniel H; Bayer, Richard R; Krazinski, Aleksander W; Dyer, Kevin T; Sandhu, Monique K; Zile, Michael R; Meinel, Felix G

    2015-04-01

    To assess the accuracy of computed tomographic (CT) examinations performed for the purpose of transcatheter aortic valve replacement (TAVR) planning to diagnose obstructive coronary artery disease (CAD). With institutional review board approval, waivers of informed consent, and in compliance with HIPAA, 100 consecutive TAVR candidates (61 men, mean age 79.6 years ± 9.9) who underwent both TAVR planning CT (with a dual-source CT system) and coronary catheter (CC) angiographic imaging were retrospectively analyzed. At both modalities, the presence of stenosis in the native coronary arteries was assessed. Additionally, all coronary bypass grafts were rated as patent or occluded. With CC angiographic imaging as the reference standard, the accuracy of CT for lesion detection on a per-vessel and per-patient basis was calculated. The accuracy of CT for the assessment of graft patency was also analyzed. For per-vessel and per-patient analysis for the detection of stenosis that was 50% or more in the native coronary arteries, CT imaging had, respectively, 94.4% and 98.6% sensitivity, 68.4% and 55.6% specificity, 94.7% and 93.8% negative predictive value (NPV), and 67.0% and 85.7% positive predictive value. Per-patient sensitivity of stenosis 50% or greater with CT for greater than 70% stenosis at CC angiographic imaging was 100%. All 12 vessels in which percutaneous coronary intervention was performed were correctly identified as demonstrating stenosis 50% or greater with CT. There was agreement between CT and CC angiographic imaging regarding graft patency in 114 of 115 grafts identified with CC angiographic imaging. TAVR planning CT has high sensitivity and NPV in excluding obstructive CAD. An additional preprocedural CC angiographic examination may not be required in TAVR candidates with a CT examination that does not show obstructive CAD. © RSNA, 2014 Online supplemental material is available for this article.

  4. ArcticDEM Validation and Accuracy Assessment

    NASA Astrophysics Data System (ADS)

    Candela, S. G.; Howat, I.; Noh, M. J.; Porter, C. C.; Morin, P. J.

    2017-12-01

    ArcticDEM comprises a growing inventory Digital Elevation Models (DEMs) covering all land above 60°N. As of August, 2017, ArcticDEM had openly released 2-m resolution, individual DEM covering over 51 million km2, which includes areas of repeat coverage for change detection, as well as over 15 million km2 of 5-m resolution seamless mosaics. By the end of the project, over 80 million km2 of 2-m DEMs will be produced, averaging four repeats of the 20 million km2 Arctic landmass. ArcticDEM is produced from sub-meter resolution, stereoscopic imagery using open source software (SETSM) on the NCSA Blue Waters supercomputer. These DEMs have known biases of several meters due to errors in the sensor models generated from satellite positioning. These systematic errors are removed through three-dimensional registration to high-precision Lidar or other control datasets. ArcticDEM is registered to seasonally-subsetted ICESat elevations due its global coverage and high report accuracy ( 10 cm). The vertical accuracy of ArcticDEM is then obtained from the statistics of the fit to the ICESat point cloud, which averages -0.01 m ± 0.07 m. ICESat, however, has a relatively coarse measurement footprint ( 70 m) which may impact the precision of the registration. Further, the ICESat data predates the ArcticDEM imagery by a decade, so that temporal changes in the surface may also impact the registration. Finally, biases may exist between different the different sensors in the ArcticDEM constellation. Here we assess the accuracy of ArcticDEM and the ICESat registration through comparison to multiple high-resolution airborne lidar datasets that were acquired within one year of the imagery used in ArcticDEM. We find the ICESat dataset is performing as anticipated, introducing no systematic bias during the coregistration process, and reducing vertical errors to within the uncertainty of the airborne Lidars. Preliminary sensor comparisons show no significant difference post coregistration

  5. Accuracy of velocities from repeated GPS surveys: relative positioning is concerned

    NASA Astrophysics Data System (ADS)

    Duman, Huseyin; Ugur Sanli, D.

    2016-04-01

    Over more than a decade, researchers have been interested in studying the accuracy of GPS positioning solutions. Recently, reporting the accuracy of GPS velocities has been added to this. Researchers studying landslide motion, tectonic motion, uplift, sea level rise, and subsidence still report results from GPS experiments in which repeated GPS measurements from short sessions are used. This motivated some other researchers to study the accuracy of GPS deformation rates/velocities from various repeated GPS surveys. In one of the efforts, the velocity accuracy was derived from repeated GPS static surveys using short observation sessions and Precise Point Positioning mode of GPS software. Velocities from short GPS sessions were compared with the velocities from 24 h sessions. The accuracy of velocities was obtained using statistical hypothesis testing and quantifying the accuracy of least squares estimation models. The results reveal that 45-60 % of the horizontal and none of the vertical solutions comply with the results from 24 h solutions. We argue that this case in which the data was evaluated using PPP should also apply to the case in which the data belonging to long GPS base lengths is processed using fundamental relative point positioning. To test this idea we chose the two IGS stations ANKR and NICO and derive their velocities from the reference stations held fixed in the stable EURASIAN plate. The University of Bern's GNSS software BERNESE was used to produce relative positioning solutions, and the results are compared with those of GIPSY/OASIS II PPP results. First impressions indicate that it is worth designing a global experiment and test these ideas in detail.

  6. Accuracy and User Performance Evaluation of a New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device.

    PubMed

    Bailey, Timothy S; Wallace, Jane F; Pardo, Scott; Warchal-Windham, Mary Ellen; Harrison, Bern; Morin, Robert; Christiansen, Mark

    2017-07-01

    The new Contour ® Plus ONE blood glucose monitoring system (BGMS) features an easy-to-use, wireless-enabled blood glucose meter that links to a smart mobile device via Bluetooth ® connectivity and can sync with the Contour ™ Diabetes app on a smartphone or tablet. The accuracy of the new BGMS was assessed in 2 studies according to ISO 15197:2013 criteria. In Study 1 (laboratory study), fingertip capillary blood samples from 100 subjects were tested in duplicate using 3 test strip lots. In Study 2 (clinical study), 134 subjects with type 1 or type 2 diabetes enrolled at 2 clinical sites. BGMS results and YSI analyzer (YSI) reference results were compared for fingertip blood obtained by untrained subjects' self-testing and for study staff-obtained fingertip, subject palm, and venous results. In Study 1, 99.0% (594/600) of combined results for all 3 test strip lots fulfilled ISO 15197:2013 Section 6.3 accuracy criteria. In Study 2, 99.2% (133/134) of subject-obtained capillary fingertip results, 99.2% (133/134) of study staff-obtained fingertip results, 99.2% (125/126) of subject-obtained palm results, and 100% (132/132) of study staff-obtained venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 95.5% (128/134) of subject-obtained fingertip self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results showed that most subjects found the BGMS easy to use. The BGMS exceeded ISO 15197:2013 accuracy criteria both in the laboratory and in a clinical setting when used by untrained subjects with diabetes.

  7. Comparison of the accuracy of kriging and IDW interpolations in estimating groundwater arsenic concentrations in Texas.

    PubMed

    Gong, Gordon; Mattevada, Sravan; O'Bryant, Sid E

    2014-04-01

    Exposure to arsenic causes many diseases. Most Americans in rural areas use groundwater for drinking, which may contain arsenic above the currently allowable level, 10µg/L. It is cost-effective to estimate groundwater arsenic levels based on data from wells with known arsenic concentrations. We compared the accuracy of several commonly used interpolation methods in estimating arsenic concentrations in >8000 wells in Texas by the leave-one-out-cross-validation technique. Correlation coefficient between measured and estimated arsenic levels was greater with inverse distance weighted (IDW) than kriging Gaussian, kriging spherical or cokriging interpolations when analyzing data from wells in the entire Texas (p<0.0001). Correlation coefficient was significantly lower with cokriging than any other methods (p<0.006) for wells in Texas, east Texas or the Edwards aquifer. Correlation coefficient was significantly greater for wells in southwestern Texas Panhandle than in east Texas, and was higher for wells in Ogallala aquifer than in Edwards aquifer (p<0.0001) regardless of interpolation methods. In regression analysis, the best models are when well depth and/or elevation were entered into the model as covariates regardless of area/aquifer or interpolation methods, and models with IDW are better than kriging in any area/aquifer. In conclusion, the accuracy in estimating groundwater arsenic level depends on both interpolation methods and wells' geographic distributions and characteristics in Texas. Taking well depth and elevation into regression analysis as covariates significantly increases the accuracy in estimating groundwater arsenic level in Texas with IDW in particular. Published by Elsevier Inc.

  8. Technics study on high accuracy crush dressing and sharpening of diamond grinding wheel

    NASA Astrophysics Data System (ADS)

    Jia, Yunhai; Lu, Xuejun; Li, Jiangang; Zhu, Lixin; Song, Yingjie

    2011-05-01

    Mechanical grinding of artificial diamond grinding wheel was traditional wheel dressing process. The rotate speed and infeed depth of tool wheel were main technics parameters. The suitable technics parameters of metals-bonded diamond grinding wheel and resin-bonded diamond grinding wheel high accuracy crush dressing were obtained by a mount of experiment in super-hard material wheel dressing grind machine and by analysis of grinding force. In the same time, the effect of machine sharpening and sprinkle granule sharpening was contrasted. These analyses and lots of experiments had extent instruction significance to artificial diamond grinding wheel accuracy crush dressing.

  9. Social Power Increases Interoceptive Accuracy

    PubMed Central

    Moeini-Jazani, Mehrad; Knoeferle, Klemens; de Molière, Laura; Gatti, Elia; Warlop, Luk

    2017-01-01

    Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental condition outperformed those in the control and low-power conditions in the Schandry heartbeat-detection task. We demonstrate that the effect of power on interoceptive accuracy is not explained by participants’ physiological arousal, affective state, or general intention for accuracy. Rather, consistent with our reasoning that experiencing power shifts attentional resources inward, we show that the effect of power on interoceptive accuracy is dependent on individuals’ chronic tendency to focus on their internal sensations. Moreover, we demonstrate that individuals’ chronic sense of power also predicts interoceptive accuracy similar to, and independent of, how their situationally induced feeling of power does. We therefore provide further support on the relation between power and enhanced perception of bodily signals. Our findings offer a novel perspective–a psychophysiological account–on how power might affect judgments and behavior. We highlight and discuss some of these intriguing possibilities for future research. PMID:28824501

  10. Improving the accuracy of k-nearest neighbor using local mean based and distance weight

    NASA Astrophysics Data System (ADS)

    Syaliman, K. U.; Nababan, E. B.; Sitompul, O. S.

    2018-03-01

    In k-nearest neighbor (kNN), the determination of classes for new data is normally performed by a simple majority vote system, which may ignore the similarities among data, as well as allowing the occurrence of a double majority class that can lead to misclassification. In this research, we propose an approach to resolve the majority vote issues by calculating the distance weight using a combination of local mean based k-nearest neighbor (LMKNN) and distance weight k-nearest neighbor (DWKNN). The accuracy of results is compared to the accuracy acquired from the original k-NN method using several datasets from the UCI Machine Learning repository, Kaggle and Keel, such as ionosphare, iris, voice genre, lower back pain, and thyroid. In addition, the proposed method is also tested using real data from a public senior high school in city of Tualang, Indonesia. Results shows that the combination of LMKNN and DWKNN was able to increase the classification accuracy of kNN, whereby the average accuracy on test data is 2.45% with the highest increase in accuracy of 3.71% occurring on the lower back pain symptoms dataset. For the real data, the increase in accuracy is obtained as high as 5.16%.

  11. Grit blasting and the marginal accuracy of two ceramic veneer systems--a pilot study.

    PubMed

    Lim, C; Ironside, J G

    1997-04-01

    Margins of ceramic restorations can be damaged during removal of investment materials with grit blasting and result in relatively large marginal discrepancies and excessive marginal discrepancies with greater exposure of cement to the oral environment. Subsequent dissolution of cement can encourage plaque retention, dental caries, and periodontal problems. This study compared marginal adaptation of ceramic veneers created by the refractory die technique (R), Dicor glass ceramic technique (D), and effects of grit blasting on their margins. Two groups of ceramic veneers were constructed for each system, one without grit blasting (R g and D g) and one with grit blasting (R+g and D+g). Statistical analyses revealed that grit blasting had a greater effect in reducing marginal accuracy for Dicor ceramic veneers compared with refractory die ceramic veneers.

  12. [Accuracy of attenuation coefficient obtained by 137Cs single-transmission scanning in PET: comparison with conventional germanium line source].

    PubMed

    Matsumoto, Keiichi; Kitamura, Keishi; Mizuta, Tetsuro; Shimizu, Keiji; Murase, Kenya; Senda, Michio

    2006-02-20

    Transmission scanning can be successfully performed with a Cs-137 single-photon-emitting point source for three-dimensional PET imaging. This method was effective for postinjection transmission scanning because of differences in physical energy. However, scatter contamination in the transmission data lowers measured attenuation coefficients. The purpose of this study was to investigate the accuracy of the influence of object scattering by measuring the attenuation coefficients on the transmission images. We also compared the results with the conventional germanium line source method. Two different types of PET scanner, the SET-3000 G/X (Shimadzu Corp.) and ECAT EXACT HR(+) (Siemens/CTI) , were used. For the transmission scanning, the SET-3000 G/X and ECAT HR(+) were the Cs-137 point source and Ge-68/Ga-68 line source, respectively. With the SET-3000 G/X, we performed transmission measurement at two energy gate settings, the standard 600-800 keV as well as 500-800 keV. The energy gate setting of the ECAT HR(+) was 350-650 keV. The effects of scattering in a uniform phantom with different cross-sectional areas ranging from 201 cm(2) to 314 cm(2) to 628 cm(2) (apposition of the two 20 cm diameter phantoms) and 943 cm(2) (stacking of the three 20 cm diameter phantoms) were acquired without emission activity. First, we evaluated the attenuation coefficients of the two different types of transmission scanning using region of interest (ROI) analysis. In addition, we evaluated the attenuation coefficients with and without segmentation for Cs-137 transmission images using the same analysis. The segmentation method was a histogram-based soft-tissue segmentation process that can also be applied to reconstructed transmission images. In the Cs-137 experiment, the maximum underestimation was 3% without segmentation, which was reduced to less than 1% with segmentation at the center of the largest phantom. In the Ge-68/Ga-68 experiment, the difference in mean attenuation

  13. Accuracy and Feasibility of Video Analysis for Assessing Hamstring Flexibility and Validity of the Sit-and-Reach Test

    ERIC Educational Resources Information Center

    Mier, Constance M.

    2011-01-01

    The accuracy of video analysis of the passive straight-leg raise test (PSLR) and the validity of the sit-and-reach test (SR) were tested in 60 men and women. Computer software measured static hip-joint flexion accurately. High within-session reliability of the PSLR was demonstrated (R greater than 0.97). Test-retest (separate days) reliability for…

  14. Accuracy of endoscopic and videofluoroscopic evaluations of swallowing for oropharyngeal dysphagia.

    PubMed

    Giraldo-Cadavid, Luis Fernando; Leal-Leaño, Lorena Renata; Leon-Basantes, Guillermo Alfredo; Bastidas, Alirio Rodrigo; Garcia, Rafael; Ovalle, Sergio; Abondano-Garavito, Jorge E

    2017-09-01

    A systematic review and meta-analysis of the literature was conducted to compare the accuracy with which flexible endoscopic evaluation of swallowing (FEES) and videofluoroscopic swallowing study (VFSS) assessed oropharyngeal dysphagia in adults. PubMed, Embase, and the Latin American and Caribbean Health Sciences Literature (LILACS) database. A review of published studies was conducted in parallel by two groups of researchers. We evaluated the methodological quality, homogeneity, threshold effect, and publication bias. The results are presented as originally published, then with each test compared against the other as a reference and both compared against a composite reference standard, and then pooled using a random effects model. Software use consisted of Meta-DiSc and SPSS. The search yielded 5,697 articles. Fifty-two articles were reviewed in full text, and six articles were included in the meta-analysis. FEES showed greater sensitivity than VFSS for aspiration (0.88 vs. 0.77; P = .03), penetration (0.97 vs. 0.83; P = .0002), and laryngopharyngeal residues (0.97 vs. 0.80; P < .0001). Sensitivity to detect pharyngeal premature spillage was similar for both tests (VFSS: 0.80; FEES: 0.69; P = .28). The specificities of both tests were similar (range, 0.93-0.98). In the sensitivity analysis there were statistically significant differences between the tests regarding residues but only marginally significant differences regarding aspiration and penetration. FEES had a slight advantage over VFSS to detect aspiration, penetration, and residues. Prospective studies comparing both tests against an appropriate reference standard are needed to define which test has greater accuracy. 2a Laryngoscope, 127:2002-2010, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Accuracy of implant impressions without impression copings: a three-dimensional analysis.

    PubMed

    Kwon, Joo-Hyun; Son, Yong-Ha; Han, Chong-Hyun; Kim, Sunjai

    2011-06-01

    Implant impressions without impression copings can be used for cement-retained implant restorations. A comparison of the accuracy of implant impressions with and without impression copings is needed. The purpose of this study was to evaluate and compare the dimensional accuracy of implant definitive casts that are fabricated by implant impressions with and without impression copings. An acrylic resin maxillary model was fabricated, and 3 implant replicas were secured in the right second premolar, first, and second molars. Two impression techniques were used to fabricate definitive casts (n=10). For the coping group (Group C), open tray impression copings were used for the final impressions. For the no-coping group (Group NC), cementable abutments were connected to the implant replicas, and final impressions were made assuming the abutments were prepared teeth. Computerized calculation of the centroids and long axes of the implant or stone abutment replicas was performed. The Mann-Whitney U test analyzed the amount of linear and rotational distortion between groups (α =.05). At the first molar site, Group NC showed significantly greater linear distortion along the Y-axis, with a small difference between the groups (Group C, 7.8 ± 7.4 μm; Group NC, 19.5 ± 12.2). At the second molar site, increased distortion was noted in Group NC for every linear and rotational variable, except for linear distortion along the Z-axis. Implant impression with open tray impression copings produced more accurate definitive casts than those fabricated without impression copings, especially those with greater inter-abutment distance. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. EVALUATION OF DIAGNOSTIC ACCURACY OF THE COMPARATIVE TUBERCULIN SKIN TEST IN REHABILITANT BORNEAN ORANGUTANS (PONGO PYGMAEUS).

    PubMed

    Dench, Rosalie; Sulistyo, Fransiska; Fahroni, Agus; Philippa, Joost

    2015-12-01

    The tuberculin skin test (TST) has been the mainstay of tuberculosis (TB) testing in primates for decades, but its interpretation in orangutans (Pongo spp.) is challenging, because many animals react strongly, without evidence of infection with Mycobacterium tuberculosis complex. One explanation is cross-reactivity with environmental nontuberculous mycobacteria (NTM). The use of a comparative TST (CTST), comparing reactivity to avian (representing NTM) and bovine (representing tuberculous mycobacteria) tuberculins aids in distinguishing cross-reactivity due to sensitization by NTM from shared antigens. The specificity of the TST can be increased with the use of CTST. We considered three interpretations of the TST in rehabilitant Bornean orangutans ( Pongo pygmaeus ) using avian purified protein derivative (APPD; 25,000 IU/ml) and two concentrations of bovine purified protein derivative (BPPD; 100,000 and 32,500 IU/ml). The tests were evaluated for their ability to identify accurately seven orangutans previously diagnosed with and treated for TB from a group of presumed negative individuals (n = 288 and n = 161 for the two respective BPPD concentrations). BPPD at 32,500 IU/ml had poor diagnostic capacity, whereas BPPD at 100,000 IU/ml performed better. The BPPD-only interpretation had moderate sensitivity (57%) and poor specificity (40%) and accuracy (41%). The comparative interpretation at 72 hr had similar sensitivity (57%) but improved specificity (95%) and accuracy (94%). However, best results were obtained by a comparative interpretation incorporating the 48- and 72-hr scores, which had good sensitivity (86%), specificity (95%) and accuracy (95%). These data reinforce recommendations that a CTST be used in orangutans and support the use of APPD at 25,000 IU/ml and BPPD at 100,000 IU/ml. The highest score at each site from the 48- and 72-hr checks should be considered the result for that tuberculin. If the bovine result is greater than the avian result, the

  17. Cellular Therapy to Obtain Rapid Endochondral Bone Formation

    DTIC Science & Technology

    2008-02-01

    efficiency of the delivery cells for optimal BMP2 production is the key parameter in determining the ex- tent of bone formation (Olmsted et al., 2001...quan- titative bone analysis software provided with the MicroCT sys- tem. For this analysis, any tissue with a hydroxyapatite density greater than 0.26...2B. Continued. B duced cells do not interfere with the osteoinductive nature of BMP2. Using set parameters to obtain equivalent functional BMP2

  18. Block Adjustment and Image Matching of WORLDVIEW-3 Stereo Pairs and Accuracy Evaluation

    NASA Astrophysics Data System (ADS)

    Zuo, C.; Xiao, X.; Hou, Q.; Li, B.

    2018-05-01

    WorldView-3, as a high-resolution commercial earth observation satellite, which is launched by Digital Global, provides panchromatic imagery of 0.31 m resolution. The positioning accuracy is less than 3.5 meter CE90 without ground control, which can use for large scale topographic mapping. This paper presented the block adjustment for WorldView-3 based on RPC model and achieved the accuracy of 1 : 2000 scale topographic mapping with few control points. On the base of stereo orientation result, this paper applied two kinds of image matching algorithm for DSM extraction: LQM and SGM. Finally, this paper compared the accuracy of the point cloud generated by the two image matching methods with the reference data which was acquired by an airborne laser scanner. The results showed that the RPC adjustment model of WorldView-3 image with small number of GCPs could satisfy the requirement of Chinese Surveying and Mapping regulations for 1 : 2000 scale topographic maps. And the point cloud result obtained through WorldView-3 stereo image matching had higher elevation accuracy, the RMS error of elevation for bare ground area is 0.45 m, while for buildings the accuracy can almost reach 1 meter.

  19. Diagnostic accuracy of EEG changes during carotid endarterectomy in predicting perioperative strokes.

    PubMed

    Thirumala, Parthasarathy D; Thiagarajan, Karthy; Gedela, Satyanarayana; Crammond, Donald J; Balzer, Jeffrey R

    2016-03-01

    The 30 day stroke rate following carotid endarterectomy (CEA) ranges between 2-6%. Such periprocedural strokes are associated with a three-fold increased risk of mortality. Our primary aim was to determine the diagnostic accuracy of electroencephalogram (EEG) in predicting perioperative strokes through meta-analysis of existing literature. An extensive search for relevant literature was undertaken using PubMed and Web of Science databases. Studies were included after screening using predetermined criteria. Data was extracted and analyzed. Summary sensitivity, specificity and diagnostic odds ratio were obtained. Subgroup analysis of studies using eight or more EEG channels was done. Perioperative stroke rate for the cohort of 8765 patients was 1.75%. Pooled sensitivity and specificity of EEG changes in predicting these strokes were 52% (95% confidence interval [CI], 43-61%) and 84% (95% CI, 81-86%) respectively. Summary estimates of the subgroup were similar. The diagnostic odds ratio was 5.85 (95% CI, 3.71-9.22). For the observed stroke rate, the positive likelihood ratio was 3.25 while the negative predictive value was 98.99%. According to these results, patients with perioperative strokes have six times greater odds of experiencing an intraoperative change in EEG during CEA. EEG monitoring was found to be highly specific in predicting perioperative strokes after CEA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Evaluating cost-efficiency and accuracy of hunter harvest survey designs

    USGS Publications Warehouse

    Lukacs, P.M.; Gude, J.A.; Russell, R.E.; Ackerman, B.B.

    2011-01-01

    Effective management of harvested wildlife often requires accurate estimates of the number of animals harvested annually by hunters. A variety of techniques exist to obtain harvest data, such as hunter surveys, check stations, mandatory reporting requirements, and voluntary reporting of harvest. Agencies responsible for managing harvested wildlife such as deer (Odocoileus spp.), elk (Cervus elaphus), and pronghorn (Antilocapra americana) are challenged with balancing the cost of data collection versus the value of the information obtained. We compared precision, bias, and relative cost of several common strategies, including hunter self-reporting and random sampling, for estimating hunter harvest using a realistic set of simulations. Self-reporting with a follow-up survey of hunters who did not report produces the best estimate of harvest in terms of precision and bias, but it is also, by far, the most expensive technique. Self-reporting with no followup survey risks very large bias in harvest estimates, and the cost increases with increased response rate. Probability-based sampling provides a substantial cost savings, though accuracy can be affected by nonresponse bias. We recommend stratified random sampling with a calibration estimator used to reweight the sample based on the proportions of hunters responding in each covariate category as the best option for balancing cost and accuracy. ?? 2011 The Wildlife Society.

  1. On-board error correction improves IR earth sensor accuracy

    NASA Astrophysics Data System (ADS)

    Alex, T. K.; Kasturirangan, K.; Shrivastava, S. K.

    1989-10-01

    Infra-red earth sensors are used in satellites for attitude sensing. Their accuracy is limited by systematic and random errors. The sources of errors in a scanning infra-red earth sensor are analyzed in this paper. The systematic errors arising from seasonal variation of infra-red radiation, oblate shape of the earth, ambient temperature of sensor, changes in scan/spin rates have been analyzed. Simple relations are derived using least square curve fitting for on-board correction of these errors. Random errors arising out of noise from detector and amplifiers, instability of alignment and localized radiance anomalies are analyzed and possible correction methods are suggested. Sun and Moon interference on earth sensor performance has seriously affected a number of missions. The on-board processor detects Sun/Moon interference and corrects the errors on-board. It is possible to obtain eight times improvement in sensing accuracy, which will be comparable with ground based post facto attitude refinement.

  2. Evaluating the Accuracy of Results for Teacher Implemented Trial-Based Functional Analyses.

    PubMed

    Rispoli, Mandy; Ninci, Jennifer; Burke, Mack D; Zaini, Samar; Hatton, Heather; Sanchez, Lisa

    2015-09-01

    Trial-based functional analysis (TBFA) allows for the systematic and experimental assessment of challenging behavior in applied settings. The purposes of this study were to evaluate a professional development package focused on training three Head Start teachers to conduct TBFAs with fidelity during ongoing classroom routines. To assess the accuracy of the TBFA results, the effects of a function-based intervention derived from the TBFA were compared with the effects of a non-function-based intervention. Data were collected on child challenging behavior and appropriate communication. An A-B-A-C-D design was utilized in which A represented baseline, and B and C consisted of either function-based or non-function-based interventions counterbalanced across participants, and D represented teacher implementation of the most effective intervention. Results showed that the function-based intervention produced greater decreases in challenging behavior and greater increases in appropriate communication than the non-function-based intervention for all three children. © The Author(s) 2015.

  3. Systematic review of discharge coding accuracy

    PubMed Central

    Burns, E.M.; Rigby, E.; Mamidanna, R.; Bottle, A.; Aylin, P.; Ziprin, P.; Faiz, O.D.

    2012-01-01

    Introduction Routinely collected data sets are increasingly used for research, financial reimbursement and health service planning. High quality data are necessary for reliable analysis. This study aims to assess the published accuracy of routinely collected data sets in Great Britain. Methods Systematic searches of the EMBASE, PUBMED, OVID and Cochrane databases were performed from 1989 to present using defined search terms. Included studies were those that compared routinely collected data sets with case or operative note review and those that compared routinely collected data with clinical registries. Results Thirty-two studies were included. Twenty-five studies compared routinely collected data with case or operation notes. Seven studies compared routinely collected data with clinical registries. The overall median accuracy (routinely collected data sets versus case notes) was 83.2% (IQR: 67.3–92.1%). The median diagnostic accuracy was 80.3% (IQR: 63.3–94.1%) with a median procedure accuracy of 84.2% (IQR: 68.7–88.7%). There was considerable variation in accuracy rates between studies (50.5–97.8%). Since the 2002 introduction of Payment by Results, accuracy has improved in some respects, for example primary diagnoses accuracy has improved from 73.8% (IQR: 59.3–92.1%) to 96.0% (IQR: 89.3–96.3), P= 0.020. Conclusion Accuracy rates are improving. Current levels of reported accuracy suggest that routinely collected data are sufficiently robust to support their use for research and managerial decision-making. PMID:21795302

  4. Fundamental Importance of Reference Glucose Analyzer Accuracy for Evaluating the Performance of Blood Glucose Monitoring Systems (BGMSs)

    PubMed Central

    Bailey, Timothy S.; Klaff, Leslie J.; Wallace, Jane F.; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A.

    2016-01-01

    Background: As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Methods: Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects’ self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. Results: In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (−0.64% to −2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. Conclusions: These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. PMID:26902794

  5. An automated method for the evaluation of the pointing accuracy of Sun-tracking devices

    NASA Astrophysics Data System (ADS)

    Baumgartner, Dietmar J.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz; Veronig, Astrid M.; Rieder, Harald E.

    2017-03-01

    The accuracy of solar radiation measurements, for direct (DIR) and diffuse (DIF) radiation, depends significantly on the precision of the operational Sun-tracking device. Thus, rigid targets for instrument performance and operation have been specified for international monitoring networks, e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices that fulfill these accuracy requirements are available from various instrument manufacturers; however, none of the commercially available systems comprise an automatic accuracy control system allowing platform operators to independently validate the pointing accuracy of Sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system-independent, and cost-effective system for evaluating the pointing accuracy of Sun-tracking devices. We detail the monitoring system setup, its design and specifications, and the results from its application to the Sun-tracking system operated at the Kanzelhöhe Observatory (KSO) Austrian radiation monitoring network (ARAD) site. The results from an evaluation campaign from March to June 2015 show that the tracking accuracy of the device operated at KSO lies within BSRN specifications (i.e., 0.1° tracking accuracy) for the vast majority of observations (99.8 %). The evaluation of manufacturer-specified active-tracking accuracies (0.02°), during periods with direct solar radiation exceeding 300 W m-2, shows that these are satisfied in 72.9 % of observations. Tracking accuracies are highest during clear-sky conditions and on days where prevailing clear-sky conditions are interrupted by frontal movement; in these cases, we obtain the complete fulfillment of BSRN requirements and 76.4 % of observations within manufacturer-specified active-tracking accuracies. Limitations to tracking surveillance arise during overcast conditions and

  6. Accuracy requirements and uncertainties in radiotherapy: a report of the International Atomic Energy Agency.

    PubMed

    van der Merwe, Debbie; Van Dyk, Jacob; Healy, Brendan; Zubizarreta, Eduardo; Izewska, Joanna; Mijnheer, Ben; Meghzifene, Ahmed

    2017-01-01

    Radiotherapy technology continues to advance and the expectation of improved outcomes requires greater accuracy in various radiotherapy steps. Different factors affect the overall accuracy of dose delivery. Institutional comprehensive quality assurance (QA) programs should ensure that uncertainties are maintained at acceptable levels. The International Atomic Energy Agency has recently developed a report summarizing the accuracy achievable and the suggested action levels, for each step in the radiotherapy process. Overview of the report: The report seeks to promote awareness and encourage quantification of uncertainties in order to promote safer and more effective patient treatments. The radiotherapy process and the radiobiological and clinical frameworks that define the need for accuracy are depicted. Factors that influence uncertainty are described for a range of techniques, technologies and systems. Methodologies for determining and combining uncertainties are presented, and strategies for reducing uncertainties through QA programs are suggested. The role of quality audits in providing international benchmarking of achievable accuracy and realistic action levels is also discussed. The report concludes with nine general recommendations: (1) Radiotherapy should be applied as accurately as reasonably achievable, technical and biological factors being taken into account. (2) For consistency in prescribing, reporting and recording, recommendations of the International Commission on Radiation Units and Measurements should be implemented. (3) Each institution should determine uncertainties for their treatment procedures. Sample data are tabulated for typical clinical scenarios with estimates of the levels of accuracy that are practically achievable and suggested action levels. (4) Independent dosimetry audits should be performed regularly. (5) Comprehensive quality assurance programs should be in place. (6) Professional staff should be appropriately

  7. Accuracy of electronic implant torque controllers following time in clinical service.

    PubMed

    Mitrani, R; Nicholls, J I; Phillips, K M; Ma, T

    2001-01-01

    Tightening of the screws in implant-supported restorations has been reported to be problematic, in that if the applied torque is too low, screw loosening occurs. If the torque is too high, then screw fracture can take place. Thus, accuracy of the torque driver is of the utmost importance. This study evaluated 4 new electronic torque drivers (controls) and 10 test electronic torque drivers, which had been in clinical service for a minimum of 5 years. Torque values of the test drivers were measured and were compared with the control values using a 1-way analysis of variance. Torque delivery accuracy was measured using a technique that simulated the clinical situation. In vivo, the torque driver turns the screw until the selected tightening torque is reached. In this laboratory experiment, an implant, along with an attached abutment and abutment gold screw, was held firmly in a Tohnichi torque gauge. Calibration accuracy for the Tohnichi is +/- 3% of the scale value. During torque measurement, the gold screw turned a minimum of 180 degrees before contact was made between the screw and abutment. Three torque values (10, 20, and 32 N-cm) were evaluated, at both high- and low-speed settings. The recorded torque measurements indicated that the 10 test electronic torque drivers maintained a torque delivery accuracy equivalent to the 4 new (unused) units. Judging from the torque output values obtained from the 10 test units, the clinical use of the electronic torque driver suggests that accuracy did not change significantly over the 5-year period of clinical service.

  8. Accuracy and precision of four value-added blood glucose meters: the Abbott Optium, the DDI Prodigy, the HDI True Track, and the HypoGuard Assure Pro.

    PubMed

    Sheffield, Catherine A; Kane, Michael P; Bakst, Gary; Busch, Robert S; Abelseth, Jill M; Hamilton, Robert A

    2009-09-01

    This study compared the accuracy and precision of four value-added glucose meters. Finger stick glucose measurements in diabetes patients were performed using the Abbott Diabetes Care (Alameda, CA) Optium, Diagnostic Devices, Inc. (Miami, FL) DDI Prodigy, Home Diagnostics, Inc. (Fort Lauderdale, FL) HDI True Track Smart System, and Arkray, USA (Minneapolis, MN) HypoGuard Assure Pro. Finger glucose measurements were compared with laboratory reference results. Accuracy was assessed by a Clarke error grid analysis (EGA), a Parkes EGA, and within 5%, 10%, 15%, and 20% of the laboratory value criteria (chi2 analysis). Meter precision was determined by calculating absolute mean differences in glucose values between duplicate samples (Kruskal-Wallis test). Finger sticks were obtained from 125 diabetes patients, of which 90.4% were Caucasian, 51.2% were female, 83.2% had type 2 diabetes, and average age of 59 years (SD 14 years). Mean venipuncture blood glucose was 151 mg/dL (SD +/-65 mg/dL; range, 58-474 mg/dL). Clinical accuracy by Clarke EGA was demonstrated in 94% of Optium, 82% of Prodigy, 61% of True Track, and 77% of the Assure Pro samples (P < 0.05 for Optium and True Track compared to all others). By Parkes EGA, the True Track was significantly less accurate than the other meters. Within 5% accuracy was achieved in 34%, 24%, 29%, and 13%, respectively (P < 0.05 for Optium, Prodigy, and Assure Pro compared to True Track). Within 10% accuracy was significantly greater for the Optium, Prodigy, and Assure Pro compared to True Track. Significantly more Optium results demonstrated within 15% and 20% accuracy compared to the other meter systems. The HDI True Track was significantly less precise than the other meter systems. The Abbott Optium was significantly more accurate than the other meter systems, whereas the HDI True Track was significantly less accurate and less precise compared to the other meter systems.

  9. Rate- and accuracy-disabled subtype profiles among adults with dyslexia in the Hebrew orthography.

    PubMed

    Shany, Michal; Breznitz, Zvia

    2011-01-01

    This study examined a subtyping scheme rooted in the dissociation between reading rate and accuracy in an exceptionally large sample of adult readers with dyslexia using a wide variety of behavioral and event-related potential (ERP) measures. Stage 1 was a behavioral study, in which basic reading skill, reading comprehension, linguistic and cognitive tasks were administered to 661 learning-disabled university students (n = 382) and their non-learning-disabled peers (n = 279). Based on a word reading measure, accuracy-disabled and rate-disabled subgroups were identified, as was a subgroup with deficits in both rate and accuracy. The results support the persistence of a rate versus accuracy dissociation into adulthood. Accuracy disability was related to a broad range of deficits affecting phonological, orthographic, and morphological processing, verbal memory, attention, and reading comprehension. Rate disability appeared to be associated with slower processing of printed material, alongside largely intact functioning resembling those of skilled readers. In stage 2, electroencephalogram (EEG)-ERP measurements were obtained from 140 participants recruited from the larger sample. Activation in visual association cortex, indicated by the N170 amplitude, was found to be lower for accuracy-disabled than skilled readers, and comparable between rate-disabled and skilled readers. The lowest amplitude was found in the double-deficit subgroup. The findings support the existence of distinctive reading disability profiles, based on selective deficits in reading rate versus accuracy and associated with different basic reading, linguistic, and cognitive skills as well as electrophysiological responses.

  10. Data accuracy assessment using enterprise architecture

    NASA Astrophysics Data System (ADS)

    Närman, Per; Holm, Hannes; Johnson, Pontus; König, Johan; Chenine, Moustafa; Ekstedt, Mathias

    2011-02-01

    Errors in business processes result in poor data accuracy. This article proposes an architecture analysis method which utilises ArchiMate and the Probabilistic Relational Model formalism to model and analyse data accuracy. Since the resources available for architecture analysis are usually quite scarce, the method advocates interviews as the primary data collection technique. A case study demonstrates that the method yields correct data accuracy estimates and is more resource-efficient than a competing sampling-based data accuracy estimation method.

  11. Comparisons of discrete and integrative sampling accuracy in estimating pulsed aquatic exposures.

    PubMed

    Morrison, Shane A; Luttbeg, Barney; Belden, Jason B

    2016-11-01

    Most current-use pesticides have short half-lives in the water column and thus the most relevant exposure scenarios for many aquatic organisms are pulsed exposures. Quantifying exposure using discrete water samples may not be accurate as few studies are able to sample frequently enough to accurately determine time-weighted average (TWA) concentrations of short aquatic exposures. Integrative sampling methods that continuously sample freely dissolved contaminants over time intervals (such as integrative passive samplers) have been demonstrated to be a promising measurement technique. We conducted several modeling scenarios to test the assumption that integrative methods may require many less samples for accurate estimation of peak 96-h TWA concentrations. We compared the accuracies of discrete point samples and integrative samples while varying sampling frequencies and a range of contaminant water half-lives (t 50  = 0.5, 2, and 8 d). Differences the predictive accuracy of discrete point samples and integrative samples were greatest at low sampling frequencies. For example, when the half-life was 0.5 d, discrete point samples required 7 sampling events to ensure median values > 50% and no sampling events reporting highly inaccurate results (defined as < 10% of the true 96-h TWA). Across all water half-lives investigated, integrative sampling only required two samples to prevent highly inaccurate results and measurements resulting in median values > 50% of the true concentration. Regardless, the need for integrative sampling diminished as water half-life increased. For an 8-d water half-life, two discrete samples produced accurate estimates and median values greater than those obtained for two integrative samples. Overall, integrative methods are the more accurate method for monitoring contaminants with short water half-lives due to reduced frequency of extreme values, especially with uncertainties around the timing of pulsed events. However, the

  12. Weight Multispectral Reconstruction Strategy for Enhanced Reconstruction Accuracy and Stability With Cerenkov Luminescence Tomography.

    PubMed

    Hongbo Guo; Xiaowei He; Muhan Liu; Zeyu Zhang; Zhenhua Hu; Jie Tian

    2017-06-01

    Cerenkov luminescence tomography (CLT) provides a novel technique for 3-D noninvasive detection of radiopharmaceuticals in living subjects. However, because of the severe scattering of Cerenkov light, the reconstruction accuracy and stability of CLT is still unsatisfied. In this paper, a modified weight multispectral CLT (wmCLT) reconstruction strategy was developed which split the Cerenkov radiation spectrum into several sub-spectral bands and weighted the sub-spectral results to obtain the final result. To better evaluate the property of the wmCLT reconstruction strategy in terms of accuracy, stability and practicability, several numerical simulation experiments and in vivo experiments were conducted and the results obtained were compared with the traditional multispectral CLT (mCLT) and hybrid-spectral CLT (hCLT) reconstruction strategies. The numerical simulation results indicated that wmCLT strategy significantly improved the accuracy of Cerenkov source localization and intensity quantitation and exhibited good stability in suppressing noise in numerical simulation experiments. And the comparison of the results achieved from different in vivo experiments further indicated significant improvement of the wmCLT strategy in terms of the shape recovery of the bladder and the spatial resolution of imaging xenograft tumors. Overall the strategy reported here will facilitate the development of nuclear and optical molecular tomography in theoretical study.

  13. Relationship between strong-motion array parameters and the accuracy of source inversion and physical waves

    USGS Publications Warehouse

    Iida, M.; Miyatake, T.; Shimazaki, K.

    1990-01-01

    We develop general rules for a strong-motion array layout on the basis of our method of applying a prediction analysis to a source inversion scheme. A systematic analysis is done to obtain a relationship between fault-array parameters and the accuracy of a source inversion. Our study of the effects of various physical waves indicates that surface waves at distant stations contribute significantly to the inversion accuracy for the inclined fault plane, whereas only far-field body waves at both small and large distances contribute to the inversion accuracy for the vertical fault, which produces more phase interference. These observations imply the adequacy of the half-space approximation used throughout our present study and suggest rules for actual array designs. -from Authors

  14. Accuracy and high-speed technique for autoprocessing of Young's fringes

    NASA Astrophysics Data System (ADS)

    Chen, Wenyi; Tan, Yushan

    1991-12-01

    In this paper, an accurate and high-speed method for auto-processing of Young's fringes is proposed. A group of 1-D sampled intensity values along three or more different directions are taken from Young's fringes, and the fringe spacings of each direction are obtained by 1-D FFT respectively. Two directions that have smaller fringe spacing are selected from all directions. The accurate fringe spacings along these two directions are obtained by using orthogonal coherent phase detection technique (OCPD). The actual spacing and angle of Young's fringes, therefore, can be calculated. In this paper, the principle of OCPD is introduced in detail. The accuracy of the method is evaluated theoretically and experimentally.

  15. Accuracy of ultrasound for the prediction of placenta accreta.

    PubMed

    Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M

    2014-08-01

    Ultrasound has been reported to be greater than 90% sensitive for the diagnosis of accreta. Prior studies may be subject to bias because of single expert observers, suspicion for accreta, and knowledge of risk factors. We aimed to assess the accuracy of ultrasound for the prediction of accreta. Patients with accreta at a single academic center were matched to patients with placenta previa, but no accreta, by year of delivery. Ultrasound studies with views of the placenta were collected, deidentified, blinded to clinical history, and placed in random sequence. Six investigators prospectively interpreted each study for the presence of accreta and findings reported to be associated with its diagnosis. Sensitivity, specificity, positive predictive, negative predictive value, and accuracy were calculated. Characteristics of accurate findings were compared using univariate and multivariate analyses. Six investigators examined 229 ultrasound studies from 55 patients with accreta and 56 controls for 1374 independent observations. 1205/1374 (87.7% overall, 90% controls, 84.9% cases) studies were given a diagnosis. There were 371 (27.0%) true positives; 81 (5.9%) false positives; 533 (38.8%) true negatives, 220 (16.0%) false negatives, and 169 (12.3%) with uncertain diagnosis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 53.5%, 88.0%, 82.1%, 64.8%, and 64.8%, respectively. In multivariate analysis, true positives were more likely to have placental lacunae (odds ratio [OR], 1.5; 95% confidence interval [CI], 1.4-1.6), loss of retroplacental clear space (OR, 2.4; 95% CI, 1.1-4.9), or abnormalities on color Doppler (OR, 2.1; 95% CI, 1.8-2.4). Ultrasound for the prediction of placenta accreta may not be as sensitive as previously described. Copyright © 2014 Mosby, Inc. All rights reserved.

  16. Accuracy of fetal sex determination on ultrasound examination in the first trimester of pregnancy.

    PubMed

    Manzanares, Sebastián; Benítez, Adara; Naveiro-Fuentes, Mariña; López-Criado, María Setefilla; Sánchez-Gila, Mar

    2016-06-01

    The aim of this study was to evaluate the feasibility and success rate of sex determination on transabdominal sonographic examination at 11-13 weeks' gestation and to identify factors influencing accuracy. In this prospective observational evaluation of 672 fetuses between 11 weeks' and 13 weeks + 6 days' gestational age (GA), we determined fetal sex according to the angle of the genital tubercle viewed on the midsagittal plane. We also analyzed maternal, fetal, and operator factors possibly influencing the accuracy of the determination. Fetal sex determination was feasible in 608 of the 672 fetuses (90.5%), and the prediction was correct in 532 of those 608 cases (87.5%). Fetal sex was more accurately predicted as the fetal crown-rump length (CRL), and GA increased and was less accurately predicted as the maternal body mass index increased. A CRL greater than 55.7 mm, a GA more than 12 weeks + 2 days, and a body mass index below 23.8 were identified as the best cutoff values for sex prediction. None of the other analyzed factors influenced the feasibility or accuracy of sex determination. The sex of a fetus can be accurately determined on sonographic examination in the first trimester of pregnancy; the accuracy of this prediction is influenced by the fetal CRL and GA and by the maternal body mass index. © 2015 Wiley Periodicals, Inc. J Clin Ultrasound 44:272-277, 2016. © 2015 Wiley Periodicals, Inc.

  17. Enhancing Visual Perception and Motor Accuracy among School Children through a Mindfulness and Compassion Program

    PubMed Central

    Tarrasch, Ricardo; Margalit-Shalom, Lilach; Berger, Rony

    2017-01-01

    The present study assessed the effects of the mindfulness/compassion cultivating program: “Call to Care-Israel” on the performance in visual perception (VP) and motor accuracy, as well as on anxiety levels and self-reported mindfulness among 4th and 5th grade students. One hundred and thirty-eight children participated in the program for 24 weekly sessions, while 78 children served as controls. Repeated measures ANOVA’s yielded significant interactions between time of measurement and group for VP, motor accuracy, reported mindfulness, and anxiety. Post hoc tests revealed significant improvements in the four aforementioned measures in the experimental group only. In addition, significant correlations were obtained between the improvement in motor accuracy and the reduction in anxiety and the increase in mindfulness. Since VP and motor accuracy are basic skills associated with quantifiable academic characteristics, such as reading and mathematical abilities, the results may suggest that mindfulness practice has the ability to improve academic achievements. PMID:28286492

  18. Establishment of a high accuracy geoid correction model and geodata edge match

    NASA Astrophysics Data System (ADS)

    Xi, Ruifeng

    This research has developed a theoretical and practical methodology for efficiently and accurately determining sub-decimeter level regional geoids and centimeter level local geoids to meet regional surveying and local engineering requirements. This research also provides a highly accurate static DGPS network data pre-processing, post-processing and adjustment method and a procedure for a large GPS network like the state level HRAN project. The research also developed an efficient and accurate methodology to join soil coverages in GIS ARE/INFO. A total of 181 GPS stations has been pre-processed and post-processed to obtain an absolute accuracy better than 1.5cm at 95% of the stations, and at all stations having a 0.5 ppm average relative accuracy. A total of 167 GPS stations in Iowa and around Iowa have been included in the adjustment. After evaluating GEOID96 and GEOID99, a more accurate and suitable geoid model has been established in Iowa. This new Iowa regional geoid model improved the accuracy from a sub-decimeter 10˜20 centimeter to 5˜10 centimeter. The local kinematic geoid model, developed using Kalman filtering, gives results better than third order leveling accuracy requirement with 1.5 cm standard deviation.

  19. Accuracy of the Garmin 920 XT HRM to perform HRV analysis.

    PubMed

    Cassirame, Johan; Vanhaesebrouck, Romain; Chevrolat, Simon; Mourot, Laurent

    2017-12-01

    Heart rate variability (HRV) analysis is widely used to investigate autonomous cardiac drive. This method requires periodogram measurement, which can be obtained by an electrocardiogram (ECG) or from a heart rate monitor (HRM), e.g. the Garmin 920 XT device. The purpose of this investigation was to assess the accuracy of RR time series measurements from a Garmin 920 XT HRM as compared to a standard ECG, and to verify whether the measurements thus obtained are suitable for HRV analysis. RR time series were collected simultaneously with an ECG (Powerlab system, AD Instruments, Castell Hill, Australia) and a Garmin XT 920 in 11 healthy subjects during three conditions, namely in the supine position, the standing position and during moderate exercise. In a first step, we compared RR time series obtained with both tools using the Bland and Altman method to obtain the limits of agreement in all three conditions. In a second step, we compared the results of HRV analysis between the ECG RR time series and Garmin 920 XT series. Results show that the accuracy of this system is in accordance with the literature in terms of the limits of agreement. In the supine position, bias was 0.01, - 2.24, + 2.26 ms; in the standing position, - 0.01, - 3.12, + 3.11 ms respectively, and during exercise, - 0.01, - 4.43 and + 4.40 ms. Regarding HRV analysis, we did not find any difference for HRV analysis in the supine position, but the standing and exercise conditions both showed small modifications.

  20. Combat veterans with comorbid PTSD and mild TBI exhibit a greater inhibitory processing ERP from the dorsal anterior cingulate cortex.

    PubMed

    Shu, I-Wei; Onton, Julie A; O'Connell, Ryan M; Simmons, Alan N; Matthews, Scott C

    2014-10-30

    Posttraumatic stress disorder (PTSD) is common among combat personnel with mild traumatic brain injury (mTBI). While patients with either PTSD or mTBI share abnormal activation of multiple frontal brain areas, anterior cingulate cortex (ACC) activity during inhibitory processing may be particularly affected by PTSD. To further test this hypothesis, we recorded electroencephalography from 32 combat veterans with mTBI-17 of whom were also comorbid for PTSD (mTBI+PTSD) and 15 without PTSD (mTBI-only). Subjects performed the Stop Task, a validated inhibitory control task requiring inhibition of initiated motor responses. We observed a larger inhibitory processing eventrelated potential (ERP) in veterans with mTBI+PTSD, including greater N200 negativity. Furthermore, greater N200 negativity correlated with greater PTSD severity. This correlation was most dependent on contributions from the dorsal ACC. Support vector machine analysis demonstrated that N200 and P300 amplitudes objectively classified veterans into mTBI-only or mTBI+PTSD groups with 79.4% accuracy. Our results support a model where, in combat veterans with mTBI, larger ERPs from cingulate areas are associated with greater PTSD severity and likely related to difficulty controlling ongoing brain processes, including trauma-related thoughts and feelings. Published by Elsevier Ireland Ltd.

  1. Accuracy of straight leg raise and slump tests in detecting lumbar disc herniation: a pilot study.

    PubMed

    M'kumbuzi, V R P; Ntawukuriryayo, J T; Haminana, J D; Munyandamutsa, J; Nzakizwanimana, E

    2012-01-01

    To determine the accuracy of the Straight Leg Raise (SLR) and slump tests in detecting Lumbar Disc Herniation (LDH). Cross-sectional diagnostic accuracy study. Two referral hospitals in Kigali, Rwanda: King Faisal Hospital and Centre Hospitalier Universitaire de Kigali. All patients aged 18 to 70 who had an MRI and who were experiencing pain in the low back, leg or low back and leg. Closed Magnetic Resonance Imaging (MRI) investigations for each patient as witnessed by a radiologist who read the image were recorded by the first researcher and blinded to other researchers. The SLR and slump tests were performed three times on each patient by independent testers who were blinded to the result of the first test. The test order was randomized for each subject and the two tests were separated by one day wash-out period. Data were analyzed using a 2x2 table to ascertain diagnostic statistics including sensitivity and specificity with 95% confidence intervals. Thirty three from a possible 37 patients mean age 41.58 ± 10 years completed all of the tests. The sensitivity of SLR was greater (0.875; CI: 0.690-0.957) than that of the slump tests (0.800; CI: 0.6087-0.911) (p = 0.01) in detecting LDH. The specificity for SLR was 0.429 (CI: 0.158-0.750) and for slump was 0.714 (CI: 0.359-0.918). Substantial agreement (K = 0.774) was obtained between the SLR and MRI. The SLR was more accurate in detecting LDH. Further validation of this pilot finding is required by studying a larger sample.

  2. Improved solution accuracy for Landsat-4 (TDRSS-user) orbit determination

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Niklewski, D. J.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1994-01-01

    This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using a Prototype Filter Smoother (PFS), with the accuracy of an established batch-least-squares system, the Goddard Trajectory Determination System (GTDS). The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and convariances for the sequential case) of solutions produced by the batch and sequential methods. The filtered and smoothed PFS orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 15 meters.

  3. Liver metal concentrations in Greater Sage-grouse (Centrocercus urophasianus).

    PubMed

    Dailey, Rebecca N; Raisbeck, Merl F; Siemion, Roger S; Cornish, Todd E

    2008-04-01

    Greater Sage-grouse (Centrocercus urophasianus) are a species of concern due to shrinking populations associated with habitat fragmentation and loss. Baseline health parameters for this species are limited or lacking, especially with regard to tissue metal concentrations. To obtain a range of tissue metal concentrations, livers were collected from 71 Greater Sage-grouse from Wyoming and Montana. Mean +/- SE metal concentrations (mg/kg wet weight) in liver were determined for vanadium (V) (0.12 +/- 0.01), chromium (Cr) (0.50 +/- 0.02), manganese (Mn) (2.68 +/- 0.11), iron (Fe) (1,019 +/- 103), nickel (Ni) (0.40 +/- 0.04), cobalt (Co) (0.08 +/- 0.02), copper (Cu) (6.43 +/- 0.40), mercury (Hg) (0.30 +/- 0.09), selenium (Se) (1.45 +/- 0.64), zinc (Zn) (59.2 +/- 4.70), molybdenum (Mo) (0.93 +/- 0.07), cadmium (Cd) (1.44 +/- 0.14), barium (Ba) (0.20 +/- 0.03), and lead (Pb) (0.17 +/- 0.03). In addition to providing baseline data, metal concentrations were compared between sex, age (juvenile/adult), and West Nile virus (WNv) groups (positive/negative). Adult birds had higher concentrations of Ni and Cd compared to juveniles. In addition, Zn and Cu concentrations were significantly elevated in WNv-positive birds.

  4. Cortical reinstatement and the confidence and accuracy of source memory.

    PubMed

    Thakral, Preston P; Wang, Tracy H; Rugg, Michael D

    2015-04-01

    Cortical reinstatement refers to the overlap between neural activity elicited during the encoding and the subsequent retrieval of an episode, and is held to reflect retrieved mnemonic content. Previous findings have demonstrated that reinstatement effects reflect the quality of retrieved episodic information as this is operationalized by the accuracy of source memory judgments. The present functional magnetic resonance imaging (fMRI) study investigated whether reinstatement-related activity also co-varies with the confidence of accurate source judgments. Participants studied pictures of objects along with their visual or spoken names. At test, they first discriminated between studied and unstudied pictures and then, for each picture judged as studied, they also judged whether it had been paired with a visual or auditory name, using a three-point confidence scale. Accuracy of source memory judgments- and hence the quality of the source-specifying information--was greater for high than for low confidence judgments. Modality-selective retrieval-related activity (reinstatement effects) also co-varied with the confidence of the corresponding source memory judgment. The findings indicate that the quality of the information supporting accurate judgments of source memory is indexed by the relative magnitude of content-selective, retrieval-related neural activity. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Accuracy assessment of BDS precision orbit determination and the influence analysis of site distribution

    NASA Astrophysics Data System (ADS)

    Chen, Ming; Guo, Jiming; Li, Zhicai; Zhang, Peng; Wu, Junli; Song, Weiwei

    2017-04-01

    BDS precision orbit determination is a key content of the BDS application, but the inadequate ground stations and the poor distribution of the network are the main reasons for the low accuracy of BDS precise orbit determination. In this paper, the BDS precise orbit determination results are obtained by using the IGS MGEX stations and the Chinese national reference stations,the accuracy of orbit determination of GEO, IGSO and MEO is 10.3cm, 2.8cm and 3.2cm, and the radial accuracy is 1.6cm,1.9cm and 1.5cm.The influence of ground reference stations distribution on BDS precise orbit determination is studied. The results show that the Chinese national reference stations contribute significantly to the BDS orbit determination, the overlap precision of GEO/IGSO/MEO satellites were improved by 15.5%, 57.5% and 5.3% respectively after adding the Chinese stations.Finally, the results of ODOP(orbit distribution of precision) and SLR are verified. Key words: BDS precise orbit determination; accuracy assessment;Chinese national reference stations;reference stations distribution;orbit distribution of precision

  6. Analysis of machining accuracy during free form surface milling simulation for different milling strategies

    NASA Astrophysics Data System (ADS)

    Matras, A.; Kowalczyk, R.

    2014-11-01

    The analysis results of machining accuracy after the free form surface milling simulations (based on machining EN AW- 7075 alloys) for different machining strategies (Level Z, Radial, Square, Circular) are presented in the work. Particular milling simulations were performed using CAD/CAM Esprit software. The accuracy of obtained allowance is defined as a difference between the theoretical surface of work piece element (the surface designed in CAD software) and the machined surface after a milling simulation. The difference between two surfaces describes a value of roughness, which is as the result of tool shape mapping on the machined surface. Accuracy of the left allowance notifies in direct way a surface quality after the finish machining. Described methodology of usage CAD/CAM software can to let improve a time design of machining process for a free form surface milling by a 5-axis CNC milling machine with omitting to perform the item on a milling machine in order to measure the machining accuracy for the selected strategies and cutting data.

  7. Comparison of hyperspectral transformation accuracies of multispectral Landsat TM, ETM+, OLI and EO-1 ALI images for detecting minerals in a geothermal prospect area

    NASA Astrophysics Data System (ADS)

    Hoang, Nguyen Tien; Koike, Katsuaki

    2018-03-01

    Hyperspectral remote sensing generally provides more detailed spectral information and greater accuracy than multispectral remote sensing for identification of surface materials. However, there have been no hyperspectral imagers that cover the entire Earth surface. This lack points to a need for producing pseudo-hyperspectral imagery by hyperspectral transformation from multispectral images. We have recently developed such a method, a Pseudo-Hyperspectral Image Transformation Algorithm (PHITA), which transforms Landsat 7 ETM+ images into pseudo-EO-1 Hyperion images using multiple linear regression models of ETM+ and Hyperion band reflectance data. This study extends the PHITA to transform TM, OLI, and EO-1 ALI sensor images into pseudo-Hyperion images. By choosing a part of the Fish Lake Valley geothermal prospect area in the western United States for study, the pseudo-Hyperion images produced from the TM, ETM+, OLI, and ALI images by PHITA were confirmed to be applicable to mineral mapping. Using a reference map as the truth, three main minerals (muscovite and chlorite mixture, opal, and calcite) were identified with high overall accuracies from the pseudo-images (> 95% and > 42% for excluding and including unclassified pixels, respectively). The highest accuracy was obtained from the ALI image, followed by ETM+, TM, and OLI images in descending order. The TM, OLI, and ALI images can be alternatives to ETM+ imagery for the hyperspectral transformation that aids the production of pseudo-Hyperion images for areas without high-quality ETM+ images because of scan line corrector failure, and for long-term global monitoring of land surfaces.

  8. Noncompliance in people living with HIV: accuracy of defining characteristics of the nursing diagnosis1.

    PubMed

    Silva, Richardson Augusto Rosendo da; Costa, Mayara Mirna do Nascimento; Souza, Vinicius Lino de; Silva, Bárbara Coeli Oliveira da; Costa, Cristiane da Silva; Andrade, Itaísa Fernandes Cardoso de

    2017-10-30

    to evaluate the accuracy of the defining characteristics of the NANDA International nursing diagnosis, noncompliance, in people with HIV. study of diagnostic accuracy, performed in two stages. In the first stage, 113 people with HIV from a hospital of infectious diseases in the Northeast of Brazil were assessed for identification of clinical indicators of noncompliance. In the second, the defining characteristics were evaluated by six specialist nurses, analyzing the presence or absence of the diagnosis. For accuracy of the clinical indicators, the specificity, sensitivity, predictive values and likelihood ratios were measured. the presence of the noncompliance diagnosis was shown in 69% (n=78) of people with HIV. The most sensitive indicator was, missing of appointments (OR: 28.93, 95% CI: 1.112-2.126, p = 0.002). On the other hand, nonadherence behavior (OR: 15.00, 95% CI: 1.829-3.981, p = 0.001) and failure to meet outcomes (OR: 13.41; 95% CI: 1.272-2.508; P = 0.003) achieved higher specificity. the most accurate defining characteristics were nonadherence behavior, missing of appointments, and failure to meet outcomes. Thus, in the presence of these, the nurse can identify, with greater security, the diagnosis studied.

  9. Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.

    1991-01-01

    The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.

  10. Comparison of ERBS orbit determination accuracy using batch least-squares and sequential methods

    NASA Astrophysics Data System (ADS)

    Oza, D. H.; Jones, T. L.; Fabien, S. M.; Mistretta, G. D.; Hart, R. C.; Doll, C. E.

    1991-10-01

    The Flight Dynamics Div. (FDD) at NASA-Goddard commissioned a study to develop the Real Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination of spacecraft on a DOS based personal computer (PC). An overview is presented of RTOD/E capabilities and the results are presented of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOS/E on a PC with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. RTOD/E was used to perform sequential orbit determination for the Earth Radiation Budget Satellite (ERBS), and the Goddard Trajectory Determination System (GTDS) was used to perform the batch least squares orbit determination. The estimated ERBS ephemerides were obtained for the Aug. 16 to 22, 1989, timeframe, during which intensive TDRSS tracking data for ERBS were available. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for ERBS; the solution differences were less than 40 meters after the filter had reached steady state.

  11. Accuracy of cytology in sub typing non small cell lung carcinomas.

    PubMed

    Patel, Trupti S; Shah, Majal G; Gandhi, Jahnavi S; Patel, Pratik

    2017-07-01

    Sub typing of non small cell lung carcinoma (NSCLC) has an important task in the era of molecular and targeted therapies. Differentiating between squamous cell carcinoma (SQCC) and adenocarcinoma (ADC) is challenging when limited material is available in lung carcinoma. We investigated the accuracy and feasibility of sub typing NSCLCs in cytology and small biopsy material. Concurrent cytology and biopsy material obtained in a single CT- guided procedure in lung carcinoma over a year period retrospectively. Both materials were individually sub typed and analyzed. Immunohistochemistry (IHC) was performed. Accuracy was determined by comparing the results with IHC. Total 107 of 126 cases of NSCLCs were included for analysis, where both cytology and biopsy material were adequate for interpretation. FNAC allowed tumor typing in 83 (77.6%) cases; 36 (33.6%) were ADC, 47 (43.9%) cases were SQCC and 24 (22.4%) cases diagnosed as Non-small cell carcinoma not otherwise specified (NSCLC-NOS). In biopsy, 86 cases (80.4%) were typed, among which 34 (31.8%) were ADC, 52 (48.6%) were SQCC and 21 (19.6%) were of NSCLC-NOS type. The result of Chi-square index was significant. With the aid of IHC, NSCLC-NOS reduced from 14 (13%) cases to 2 (1.9%) cases. Cytology and small biopsy specimens achieved comparable specificity and accuracy in sub-typing NSCLC and optimal results were obtain when findings from both modalities combine. The advantage of paired specimens is to maximize overall diagnostic yield and the remaining material will be available for ancillary technique like IHC or for molecular testing. Diagn. Cytopathol. 2017;45:598-603. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. Sympathetic preganglionic efferent and afferent neurons mediated by the greater splanchnic nerve in rabbit

    NASA Technical Reports Server (NTRS)

    Torigoe, Yasuhiro; Cernucan, Roxana D.; Nishimoto, Jo Ann S.; Blanks, Robert H. I.

    1985-01-01

    As a part of the study of the vestibular-autonomic pathways involved in motion sickness, the location and the morphology of preganglionic sympathetic neurons (PSNs) projecting via the greater splanchnic nerve were examined. Retrograde labeling of neurons was obtained by application of horseradish peroxidase to the cut end of the greater splanchnic nerve. Labeled PSNs were found, ipsilaterally, within the T1 to T11 spinal cord segments, with the highest density of neurons in T6. Most PSNs were located within the intermediolateral column, but a significant portion also occurred within the lateral funiculus, the intercalated region, and the central autonomic area; the proportion of labeling between the four regions depended on the spinal cord segment.

  13. Accuracy of Nonverbal Communication as Determinant of Interpersonal Expectancy Effects

    ERIC Educational Resources Information Center

    Zuckerman, Miron; And Others

    1978-01-01

    The person perception paradigm was used to address the effects of experimenters' ability to encode nonverbal cues and subjects' ability to decode nonverbal cues on magnitude of expectancy effects. Greater expectancy effects were obtained when experimenters were better encoders and subjects were better decoders of nonverbal cues. (Author)

  14. High accuracy operon prediction method based on STRING database scores.

    PubMed

    Taboada, Blanca; Verde, Cristina; Merino, Enrique

    2010-07-01

    We present a simple and highly accurate computational method for operon prediction, based on intergenic distances and functional relationships between the protein products of contiguous genes, as defined by STRING database (Jensen,L.J., Kuhn,M., Stark,M., Chaffron,S., Creevey,C., Muller,J., Doerks,T., Julien,P., Roth,A., Simonovic,M. et al. (2009) STRING 8-a global view on proteins and their functional interactions in 630 organisms. Nucleic Acids Res., 37, D412-D416). These two parameters were used to train a neural network on a subset of experimentally characterized Escherichia coli and Bacillus subtilis operons. Our predictive model was successfully tested on the set of experimentally defined operons in E. coli and B. subtilis, with accuracies of 94.6 and 93.3%, respectively. As far as we know, these are the highest accuracies ever obtained for predicting bacterial operons. Furthermore, in order to evaluate the predictable accuracy of our model when using an organism's data set for the training procedure, and a different organism's data set for testing, we repeated the E. coli operon prediction analysis using a neural network trained with B. subtilis data, and a B. subtilis analysis using a neural network trained with E. coli data. Even for these cases, the accuracies reached with our method were outstandingly high, 91.5 and 93%, respectively. These results show the potential use of our method for accurately predicting the operons of any other organism. Our operon predictions for fully-sequenced genomes are available at http://operons.ibt.unam.mx/OperonPredictor/.

  15. Is diagnostic accuracy for detecting pulmonary nodules in chest CT reduced after a long day of reading?

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Berbaum, Kevin S.; Caldwell, Robert; Schartz, Kevin M.

    2012-02-01

    Radiologists are reading more cases with more images, especially in CT and MRI and thus working longer hours than ever before. There have been concerns raised regarding fatigue and whether it impacts diagnostic accuracy. This study measured the impact of reader visual fatigue by assessing symptoms, visual strain via dark focus of accommodation, and diagnostic accuracy. Twenty radiologists and 20 radiology residents were given two diagnostic performance tests searching CT chest sequences for a solitary pulmonary nodule before (rested) and after (tired) a day of clinical reading. 10 cases used free search and navigation, and the other 100 cases used preset scrolling speed and duration. Subjects filled out the Swedish Occupational Fatigue Inventory (SOFI) and the oculomotor strain subscale of the Simulator Sickness Questionnaire (SSQ) before each session. Accuracy was measured using ROC techniques. Using Swensson's technique yields an ROC area = 0.86 rested vs. 0.83 tired, p (one-tailed) = 0.09. Using Swensson's LROC technique yields an area = 0.73 rested vs. 0.66 tired, p (one-tailed) = 0.09. Using Swensson's Loc Accuracy technique yields an area = 0.77 rested vs. 0.72 tired, p (one-tailed) = 0.13). Subjective measures of fatigue increased significantly from early to late reading. To date, the results support our findings with static images and detection of bone fractures. Radiologists at the end of a long work day experience greater levels of measurable visual fatigue or strain, contributing to a decrease in diagnostic accuracy. The decrease in accuracy was not as great however as with static images.

  16. Four Reasons to Question the Accuracy of a Biotic Index; the Risk of Metric Bias and the Scope to Improve Accuracy

    PubMed Central

    Monaghan, Kieran A.

    2016-01-01

    Natural ecological variability and analytical design can bias the derived value of a biotic index through the variable influence of indicator body-size, abundance, richness, and ascribed tolerance scores. Descriptive statistics highlight this risk for 26 aquatic indicator systems; detailed analysis is provided for contrasting weighted-average indices applying the example of the BMWP, which has the best supporting data. Differences in body size between taxa from respective tolerance classes is a common feature of indicator systems; in some it represents a trend ranging from comparatively small pollution tolerant to larger intolerant organisms. Under this scenario, the propensity to collect a greater proportion of smaller organisms is associated with negative bias however, positive bias may occur when equipment (e.g. mesh-size) selectively samples larger organisms. Biotic indices are often derived from systems where indicator taxa are unevenly distributed along the gradient of tolerance classes. Such skews in indicator richness can distort index values in the direction of taxonomically rich indicator classes with the subsequent degree of bias related to the treatment of abundance data. The misclassification of indicator taxa causes bias that varies with the magnitude of the misclassification, the relative abundance of misclassified taxa and the treatment of abundance data. These artifacts of assessment design can compromise the ability to monitor biological quality. The statistical treatment of abundance data and the manipulation of indicator assignment and class richness can be used to improve index accuracy. While advances in methods of data collection (i.e. DNA barcoding) may facilitate improvement, the scope to reduce systematic bias is ultimately limited to a strategy of optimal compromise. The shortfall in accuracy must be addressed by statistical pragmatism. At any particular site, the net bias is a probabilistic function of the sample data, resulting in an

  17. Determining dynamical parameters of the Milky Way Galaxy based on high-accuracy radio astrometry

    NASA Astrophysics Data System (ADS)

    Honma, Mareki; Nagayama, Takumi; Sakai, Nobuyuki

    2015-08-01

    In this paper we evaluate how the dynamical structure of the Galaxy can be constrained by high-accuracy VLBI (Very Long Baseline Interferometry) astrometry such as VERA (VLBI Exploration of Radio Astrometry). We generate simulated samples of maser sources which follow the gas motion caused by a spiral or bar potential, with their distribution similar to those currently observed with VERA and VLBA (Very Long Baseline Array). We apply the Markov chain Monte Carlo analyses to the simulated sample sources to determine the dynamical parameter of the models. We show that one can successfully determine the initial model parameters if astrometric results are obtained for a few hundred sources with currently achieved astrometric accuracy. If astrometric data are available from 500 sources, the expected accuracy of R0 and Θ0 is ˜ 1% or higher, and parameters related to the spiral structure can be constrained by an error of 10% or with higher accuracy. We also show that the parameter determination accuracy is basically independent of the locations of resonances such as corotation and/or inner/outer Lindblad resonances. We also discuss the possibility of model selection based on the Bayesian information criterion (BIC), and demonstrate that BIC can be used to discriminate different dynamical models of the Galaxy.

  18. Spacecraft attitude determination accuracy from mission experience

    NASA Technical Reports Server (NTRS)

    Brasoveanu, D.; Hashmall, J.; Baker, D.

    1994-01-01

    This document presents a compilation of the attitude accuracy attained by a number of satellites that have been supported by the Flight Dynamics Facility (FDF) at Goddard Space Flight Center (GSFC). It starts with a general description of the factors that influence spacecraft attitude accuracy. After brief descriptions of the missions supported, it presents the attitude accuracy results for currently active and older missions, including both three-axis stabilized and spin-stabilized spacecraft. The attitude accuracy results are grouped by the sensor pair used to determine the attitudes. A supplementary section is also included, containing the results of theoretical computations of the effects of variation of sensor accuracy on overall attitude accuracy.

  19. Atomic data from the IRON Project. XXXII. On the accuracy of the effective collision strength for the electron impact excitation of the quadrupole transition in AR III

    NASA Astrophysics Data System (ADS)

    Galavís, M. E.; Mendoza, C.; Zeippen, C. J.

    1998-12-01

    Since te[Burgess et al. (1997)]{bur97} have recently questioned the accuracy of the effective collision strength calculated in the IRON Project for the electron impact excitation of the 3ssp23p sp4 \\ sp1 D -sp1 S quadrupole transition in Ar iii, an extended R-matrix calculation has been performed for this transition. The original 24-state target model was maintained, but the energy regime was increased to 100 Ryd. It is shown that in order to ensure convergence of the partial wave expansion at such energies, it is necessary to take into account partial collision strengths up to L=30 and to ``top-up'' with a geometric series procedure. By comparing effective collision strengths, it is found that the differences from the original calculation are not greater than 25% around the upper end of the common temperature range and that they are much smaller than 20% over most of it. This is consistent with the accuracy rating (20%) previously assigned to transitions in this low ionisation system. Also the present high-temperature limit agrees fairly well (15%) with the Coulomb-Born limit estimated by Burgess et al., thus confirming our previous accuracy rating. It appears that Burgess et al., in their data assessment, have overextended the low-energy behaviour of our reduced effective collision strength to obtain an extrapolated high-temperature limit that appeared to be in error by a factor of 2.

  20. Improved accuracy for finite element structural analysis via an integrated force method

    NASA Technical Reports Server (NTRS)

    Patnaik, S. N.; Hopkins, D. A.; Aiello, R. A.; Berke, L.

    1992-01-01

    A comparative study was carried out to determine the accuracy of finite element analyses based on the stiffness method, a mixed method, and the new integrated force and dual integrated force methods. The numerical results were obtained with the following software: MSC/NASTRAN and ASKA for the stiffness method; an MHOST implementation method for the mixed method; and GIFT for the integrated force methods. The results indicate that on an overall basis, the stiffness and mixed methods present some limitations. The stiffness method generally requires a large number of elements in the model to achieve acceptable accuracy. The MHOST method tends to achieve a higher degree of accuracy for course models than does the stiffness method implemented by MSC/NASTRAN and ASKA. The two integrated force methods, which bestow simultaneous emphasis on stress equilibrium and strain compatibility, yield accurate solutions with fewer elements in a model. The full potential of these new integrated force methods remains largely unexploited, and they hold the promise of spawning new finite element structural analysis tools.

  1. Multi-grid finite element method used for enhancing the reconstruction accuracy in Cerenkov luminescence tomography

    NASA Astrophysics Data System (ADS)

    Guo, Hongbo; He, Xiaowei; Liu, Muhan; Zhang, Zeyu; Hu, Zhenhua; Tian, Jie

    2017-03-01

    Cerenkov luminescence tomography (CLT), as a promising optical molecular imaging modality, can be applied to cancer diagnostic and therapeutic. Most researches about CLT reconstruction are based on the finite element method (FEM) framework. However, the quality of FEM mesh grid is still a vital factor to restrict the accuracy of the CLT reconstruction result. In this paper, we proposed a multi-grid finite element method framework, which was able to improve the accuracy of reconstruction. Meanwhile, the multilevel scheme adaptive algebraic reconstruction technique (MLS-AART) based on a modified iterative algorithm was applied to improve the reconstruction accuracy. In numerical simulation experiments, the feasibility of our proposed method were evaluated. Results showed that the multi-grid strategy could obtain 3D spatial information of Cerenkov source more accurately compared with the traditional single-grid FEM.

  2. Effect of pH Test-Strip Characteristics on Accuracy of Readings.

    PubMed

    Metheny, Norma A; Gunn, Emily M; Rubbelke, Cynthia S; Quillen, Terrilynn Fox; Ezekiel, Uthayashanker R; Meert, Kathleen L

    2017-06-01

    Little is known about characteristics of colorimetric pH test strips that are most likely to be associated with accurate interpretations in clinical situations. To compare the accuracy of 4 pH test strips with varying characteristics (ie, multiple vs single colorimetric squares per calibration, and differing calibration units [1.0 vs 0.5]). A convenience sample of 100 upper-level nursing students with normal color vision was recruited to evaluate the accuracy of the test strips. Six buffer solutions (pH range, 3.0 to 6.0) were used during the testing procedure. Each of the 100 participants performed 20 pH tests in random order, providing a total of 2000 readings. The sensitivity and specificity of each test strip was computed. In addition, the degree to which the test strips under- or overestimated the pH values was analyzed using descriptive statistics. Our criterion for correct readings was an exact match with the pH buffer solution being evaluated. Although none of the test strips evaluated in our study was 100% accurate at all of the measured pH values, those with multiple squares per pH calibration were clearly superior overall to those with a single test square. Test strips with multiple squares per calibration were associated with greater overall accuracy than test strips with a single square per calibration. However, because variable degrees of error were observed in all of the test strips, use of a pH meter is recommended when precise readings are crucial. ©2017 American Association of Critical-Care Nurses.

  3. Measurement methods and accuracy analysis of Chang'E-5 Panoramic Camera installation parameters

    NASA Astrophysics Data System (ADS)

    Yan, Wei; Ren, Xin; Liu, Jianjun; Tan, Xu; Wang, Wenrui; Chen, Wangli; Zhang, Xiaoxia; Li, Chunlai

    2016-04-01

    Chang'E-5 (CE-5) is a lunar probe for the third phase of China Lunar Exploration Project (CLEP), whose main scientific objectives are to implement lunar surface sampling and to return the samples back to the Earth. To achieve these goals, investigation of lunar surface topography and geological structure within sampling area seems to be extremely important. The Panoramic Camera (PCAM) is one of the payloads mounted on CE-5 lander. It consists of two optical systems which installed on a camera rotating platform. Optical images of sampling area can be obtained by PCAM in the form of a two-dimensional image and a stereo images pair can be formed by left and right PCAM images. Then lunar terrain can be reconstructed based on photogrammetry. Installation parameters of PCAM with respect to CE-5 lander are critical for the calculation of exterior orientation elements (EO) of PCAM images, which is used for lunar terrain reconstruction. In this paper, types of PCAM installation parameters and coordinate systems involved are defined. Measurement methods combining camera images and optical coordinate observations are studied for this work. Then research contents such as observation program and specific solution methods of installation parameters are introduced. Parametric solution accuracy is analyzed according to observations obtained by PCAM scientifically validated experiment, which is used to test the authenticity of PCAM detection process, ground data processing methods, product quality and so on. Analysis results show that the accuracy of the installation parameters affects the positional accuracy of corresponding image points of PCAM stereo images within 1 pixel. So the measurement methods and parameter accuracy studied in this paper meet the needs of engineering and scientific applications. Keywords: Chang'E-5 Mission; Panoramic Camera; Installation Parameters; Total Station; Coordinate Conversion

  4. Accuracy and reliability of observational gait analysis data: judgments of push-off in gait after stroke.

    PubMed

    McGinley, Jennifer L; Goldie, Patricia A; Greenwood, Kenneth M; Olney, Sandra J

    2003-02-01

    Physical therapists routinely observe gait in clinical practice. The purpose of this study was to determine the accuracy and reliability of observational assessments of push-off in gait after stroke. Eighteen physical therapists and 11 subjects with hemiplegia following a stroke participated in the study. Measurements of ankle power generation were obtained from subjects following stroke using a gait analysis system. Concurrent videotaped gait performances were observed by the physical therapists on 2 occasions. Ankle power generation at push-off was scored as either normal or abnormal using two 11-point rating scales. These observational ratings were correlated with the measurements of peak ankle power generation. A high correlation was obtained between the observational ratings and the measurements of ankle power generation (mean Pearson r=.84). Interobserver reliability was moderately high (mean intraclass correlation coefficient [ICC (2,1)]=.76). Intraobserver reliability also was high, with a mean ICC (2,1) of.89 obtained. Physical therapists were able to make accurate and reliable judgments of push-off in videotaped gait of subjects following stroke using observational assessment. Further research is indicated to explore the accuracy and reliability of data obtained with observational gait analysis as it occurs in clinical practice.

  5. Comparative analysis of semantic localization accuracies between adult and pediatric DICOM CT images

    NASA Astrophysics Data System (ADS)

    Robertson, Duncan; Pathak, Sayan D.; Criminisi, Antonio; White, Steve; Haynor, David; Chen, Oliver; Siddiqui, Khan

    2012-02-01

    Existing literature describes a variety of techniques for semantic annotation of DICOM CT images, i.e. the automatic detection and localization of anatomical structures. Semantic annotation facilitates enhanced image navigation, linkage of DICOM image content and non-image clinical data, content-based image retrieval, and image registration. A key challenge for semantic annotation algorithms is inter-patient variability. However, while the algorithms described in published literature have been shown to cope adequately with the variability in test sets comprising adult CT scans, the problem presented by the even greater variability in pediatric anatomy has received very little attention. Most existing semantic annotation algorithms can only be extended to work on scans of both adult and pediatric patients by adapting parameters heuristically in light of patient size. In contrast, our approach, which uses random regression forests ('RRF'), learns an implicit model of scale variation automatically using training data. In consequence, anatomical structures can be localized accurately in both adult and pediatric CT studies without the need for parameter adaptation or additional information about patient scale. We show how the RRF algorithm is able to learn scale invariance from a combined training set containing a mixture of pediatric and adult scans. Resulting localization accuracy for both adult and pediatric data remains comparable with that obtained using RRFs trained and tested using only adult data.

  6. Geoid undulation accuracy

    NASA Technical Reports Server (NTRS)

    Rapp, Richard H.

    1993-01-01

    The determination of the geoid and equipotential surface of the Earth's gravity field, has long been of interest to geodesists and oceanographers. The geoid provides a surface to which the actual ocean surface can be compared with the differences implying information on the circulation patterns of the oceans. For use in oceanographic applications the geoid is ideally needed to a high accuracy and to a high resolution. There are applications that require geoid undulation information to an accuracy of +/- 10 cm with a resolution of 50 km. We are far from this goal today but substantial improvement in geoid determination has been made. In 1979 the cumulative geoid undulation error to spherical harmonic degree 20 was +/- 1.4 m for the GEM10 potential coefficient model. Today the corresponding value has been reduced to +/- 25 cm for GEM-T3 or +/- 11 cm for the OSU91A model. Similar improvements are noted by harmonic degree (wave-length) and in resolution. Potential coefficient models now exist to degree 360 based on a combination of data types. This paper discusses the accuracy changes that have taken place in the past 12 years in the determination of geoid undulations.

  7. Matters of accuracy and conventionality: prior accuracy guides children's evaluations of others' actions.

    PubMed

    Scofield, Jason; Gilpin, Ansley Tullos; Pierucci, Jillian; Morgan, Reed

    2013-03-01

    Studies show that children trust previously reliable sources over previously unreliable ones (e.g., Koenig, Clément, & Harris, 2004). However, it is unclear from these studies whether children rely on accuracy or conventionality to determine the reliability and, ultimately, the trustworthiness of a particular source. In the current study, 3- and 4-year-olds were asked to endorse and imitate one of two actors performing an unfamiliar action, one actor who was unconventional but successful and one who was conventional but unsuccessful. These data demonstrated that children preferred endorsing and imitating the unconventional but successful actor. Results suggest that when the accuracy and conventionality of a source are put into conflict, children may give priority to accuracy over conventionality when estimating the source's reliability and, ultimately, when deciding who to trust.

  8. Role of the greater sciatic notch of the hip bone in sexual dimorphism: a morphometric study of the north Indian population.

    PubMed

    G, Kalsey; R K, Singla; K, Sachdeva

    2011-04-01

    The distinctive morphology and sexual dimorphism of the human hip bone makes it of interest from the anatomical, anthropological and forensic points of view. The shape of the greater sciatic notch has attracted great attention in the past. In the current investigation, an attempt has been made to find the baseline data of various parameters pertaining to the greater sciatic notch of 100 hip bones of known sex (male:female = 80:20) and side (right:left = 50:50), obtained from the Department of Anatomy, Government Medical College, Amritsar, Punjab, India, during the period 2007-2009. Seven parameters of the notch, viz. width, depth, posterior segment width, total angle, posterior segment angle, index I and index II of the greater sciatic notch were studied. The results thus obtained were compiled, tabulated, statistically analysed and were compared with the accessible literature. Out of all the parameters studied, width of the notch, posterior segment width, total angle, posterior segment angle and index II of notch were found to be significantly greater in women as compared with men. Thus the greater sciatic notch can serve as a reliable sex indicator even when the complete hip bone has not been well preserved.

  9. An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy.

    PubMed

    Liao, Yuliang; Wang, Linjing; Xu, Xiangdong; Chen, Haibin; Chen, Jiawei; Zhang, Guoqian; Lei, Huaiyu; Wang, Ruihao; Zhang, Shuxu; Gu, Xuejun; Zhen, Xin; Zhou, Linghong

    2017-06-01

    To design and construct a three-dimensional (3D) anthropomorphic abdominal phantom for geometric accuracy and dose summation accuracy evaluations of deformable image registration (DIR) algorithms for adaptive radiation therapy (ART). Organ molds, including liver, kidney, spleen, stomach, vertebra, and two metastasis tumors, were 3D printed using contours from an ovarian cancer patient. The organ molds were molded with deformable gels made of different mixtures of polyvinyl chloride (PVC) and the softener dioctyl terephthalate. Gels with different densities were obtained by a polynomial fitting curve that described the relation between the Hounsfield unit (HU) and PVC-softener blending ratio. The rigid vertebras were constructed by molding of white cement and cellulose pulp. The final abdominal phantom was assembled by arranging all the fabricated organs inside a hollow dummy according to their anatomies, and sealed by deformable gel with averaged HU of muscle and fat. Fiducial landmarks were embedded inside the phantom for spatial accuracy and dose accumulation accuracy studies. Two channels were excavated to facilitate ionization chamber insertion for dosimetric measurements. Phantom properties such as deformable gel elasticity and HU stability were studied. The dosimetric measurement accuracy in the phantom was performed, and the DIR accuracies of three DIR algorithms available in the open source DIR toolkit-DIRART were also validated. The constructed deformable gel showed elastic behavior and was stable in HU values over times, proving to be a practical material for the deformable phantom. The constructed abdominal phantom consisted of realistic anatomies in terms of both anatomical shapes and densities when compared with its reference patient. The dosimetric measurements showed a good agreement with the calculated doses from the treatment planning system. Fiducial-based accuracy analysis conducted on the constructed phantom demonstrated the feasibility of

  10. Accuracy of pedicle screw placement comparing robot-assisted technology and the free-hand with fluoroscopy-guided method in spine surgery: An updated meta-analysis.

    PubMed

    Fan, Yong; Du, Jin Peng; Liu, Ji Jun; Zhang, Jia Nan; Qiao, Huan Huan; Liu, Shi Chang; Hao, Ding Jun

    2018-06-01

    A miniature spine-mounted robot has recently been introduced to further improve the accuracy of pedicle screw placement in spine surgery. However, the differences in accuracy between the robotic-assisted (RA) technique and the free-hand with fluoroscopy-guided (FH) method for pedicle screw placement are controversial. A meta-analysis was conducted to focus on this problem. Several randomized controlled trials (RCTs) and cohort studies involving RA and FH and published before January 2017 were searched for using the Cochrane Library, Ovid, Web of Science, PubMed, and EMBASE databases. A total of 55 papers were selected. After the full-text assessment, 45 clinical trials were excluded. The final meta-analysis included 10 articles. The accuracy of pedicle screw placement within the RA group was significantly greater than the accuracy within the FH group (odds ratio 95%, "perfect accuracy" confidence interval: 1.38-2.07, P < .01; odds ratio 95% "clinically acceptable" Confidence Interval: 1.17-2.08, P < .01). There are significant differences in accuracy between RA surgery and FH surgery. It was demonstrated that the RA technique is superior to the conventional method in terms of the accuracy of pedicle screw placement.

  11. Anatomy-aware measurement of segmentation accuracy

    NASA Astrophysics Data System (ADS)

    Tizhoosh, H. R.; Othman, A. A.

    2016-03-01

    Quantifying the accuracy of segmentation and manual delineation of organs, tissue types and tumors in medical images is a necessary measurement that suffers from multiple problems. One major shortcoming of all accuracy measures is that they neglect the anatomical significance or relevance of different zones within a given segment. Hence, existing accuracy metrics measure the overlap of a given segment with a ground-truth without any anatomical discrimination inside the segment. For instance, if we understand the rectal wall or urethral sphincter as anatomical zones, then current accuracy measures ignore their significance when they are applied to assess the quality of the prostate gland segments. In this paper, we propose an anatomy-aware measurement scheme for segmentation accuracy of medical images. The idea is to create a "master gold" based on a consensus shape containing not just the outline of the segment but also the outlines of the internal zones if existent or relevant. To apply this new approach to accuracy measurement, we introduce the anatomy-aware extensions of both Dice coefficient and Jaccard index and investigate their effect using 500 synthetic prostate ultrasound images with 20 different segments for each image. We show that through anatomy-sensitive calculation of segmentation accuracy, namely by considering relevant anatomical zones, not only the measurement of individual users can change but also the ranking of users' segmentation skills may require reordering.

  12. Accuracy of genomic selection models in a large population of open-pollinated families in white spruce

    PubMed Central

    Beaulieu, J; Doerksen, T; Clément, S; MacKay, J; Bousquet, J

    2014-01-01

    Genomic selection (GS) is of interest in breeding because of its potential for predicting the genetic value of individuals and increasing genetic gains per unit of time. To date, very few studies have reported empirical results of GS potential in the context of large population sizes and long breeding cycles such as for boreal trees. In this study, we assessed the effectiveness of marker-aided selection in an undomesticated white spruce (Picea glauca (Moench) Voss) population of large effective size using a GS approach. A discovery population of 1694 trees representative of 214 open-pollinated families from 43 natural populations was phenotyped for 12 wood and growth traits and genotyped for 6385 single-nucleotide polymorphisms (SNPs) mined in 2660 gene sequences. GS models were built to predict estimated breeding values using all the available SNPs or SNP subsets of the largest absolute effects, and they were validated using various cross-validation schemes. The accuracy of genomic estimated breeding values (GEBVs) varied from 0.327 to 0.435 when the training and the validation data sets shared half-sibs that were on average 90% of the accuracies achieved through traditionally estimated breeding values. The trend was also the same for validation across sites. As expected, the accuracy of GEBVs obtained after cross-validation with individuals of unknown relatedness was lower with about half of the accuracy achieved when half-sibs were present. We showed that with the marker densities used in the current study, predictions with low to moderate accuracy could be obtained within a large undomesticated population of related individuals, potentially resulting in larger gains per unit of time with GS than with the traditional approach. PMID:24781808

  13. Spectral Accuracy and Sulfur Counting Capabilities of the LTQ-FT-ICR and the LTQ-Orbitrap XL for Small Molecule Analysis

    NASA Astrophysics Data System (ADS)

    Blake, Samantha L.; Walker, S. Hunter; Muddiman, David C.; Hinks, David; Beck, Keith R.

    2011-12-01

    Color Index Disperse Yellow 42 (DY42), a high-volume disperse dye for polyester, was used to compare the capabilities of the LTQ-Orbitrap XL and the LTQ-FT-ICR with respect to mass measurement accuracy (MMA), spectral accuracy, and sulfur counting. The results of this research will be used in the construction of a dye database for forensic purposes; the additional spectral information will increase the confidence in the identification of unknown dyes found in fibers at crime scenes. Initial LTQ-Orbitrap XL data showed MMAs greater than 3 ppm and poor spectral accuracy. Modification of several Orbitrap installation parameters (e.g., deflector voltage) resulted in a significant improvement of the data. The LTQ-FT-ICR and LTQ-Orbitrap XL (after installation parameters were modified) exhibited MMA ≤ 3 ppm, good spectral accuracy (χ2 values for the isotopic distribution ≤ 2), and were correctly able to ascertain the number of sulfur atoms in the compound at all resolving powers investigated for AGC targets of 5.00 × 105 and 1.00 × 106.

  14. Dynamic Assessment of School-Age Children's Narrative Ability: An Experimental Investigation of Classification Accuracy

    ERIC Educational Resources Information Center

    Pena, Elizabeth D.; Gillam, Ronald B.; Malek, Melynn; Ruiz-Felter, Roxanna; Resendiz, Maria; Fiestas, Christine; Sabel, Tracy

    2006-01-01

    Two experiments examined reliability and classification accuracy of a narration-based dynamic assessment task. Purpose: The first experiment evaluated whether parallel results were obtained from stories created in response to 2 different wordless picture books. If so, the tasks and measures would be appropriate for assessing pretest and posttest…

  15. Maximum angular accuracy of pulsed laser radar in photocounting limit.

    PubMed

    Elbaum, M; Diament, P; King, M; Edelson, W

    1977-07-01

    To estimate the angular position of targets with pulsed laser radars, their images may be sensed with a fourquadrant noncoherent detector and the image photocounting distribution processed to obtain the angular estimates. The limits imposed on the accuracy of angular estimation by signal and background radiation shot noise, dark current noise, and target cross-section fluctuations are calculated. Maximum likelihood estimates of angular positions are derived for optically rough and specular targets and their performances compared with theoretical lower bounds.

  16. The Accuracy and Precision of Flow Measurements Using Phase Contrast Techniques

    NASA Astrophysics Data System (ADS)

    Tang, Chao

    Quantitative volume flow rate measurements using the magnetic resonance imaging technique are studied in this dissertation because the volume flow rates have a special interest in the blood supply of the human body. The method of quantitative volume flow rate measurements is based on the phase contrast technique, which assumes a linear relationship between the phase and flow velocity of spins. By measuring the phase shift of nuclear spins and integrating velocity across the lumen of the vessel, we can determine the volume flow rate. The accuracy and precision of volume flow rate measurements obtained using the phase contrast technique are studied by computer simulations and experiments. The various factors studied include (1) the partial volume effect due to voxel dimensions and slice thickness relative to the vessel dimensions; (2) vessel angulation relative to the imaging plane; (3) intravoxel phase dispersion; (4) flow velocity relative to the magnitude of the flow encoding gradient. The partial volume effect is demonstrated to be the major obstacle to obtaining accurate flow measurements for both laminar and plug flow. Laminar flow can be measured more accurately than plug flow in the same condition. Both the experiment and simulation results for laminar flow show that, to obtain the accuracy of volume flow rate measurements to within 10%, at least 16 voxels are needed to cover the vessel lumen. The accuracy of flow measurements depends strongly on the relative intensity of signal from stationary tissues. A correction method is proposed to compensate for the partial volume effect. The correction method is based on a small phase shift approximation. After the correction, the errors due to the partial volume effect are compensated, allowing more accurate results to be obtained. An automatic program based on the correction method is developed and implemented on a Sun workstation. The correction method is applied to the simulation and experiment results. The

  17. Feasibility of in situ, high-resolution correlation of tracer uptake with histopathology by quantitative autoradiography of biopsy specimens obtained under 18F-FDG PET/CT guidance.

    PubMed

    Fanchon, Louise M; Dogan, Snjezana; Moreira, Andre L; Carlin, Sean A; Schmidtlein, C Ross; Yorke, Ellen; Apte, Aditya P; Burger, Irene A; Durack, Jeremy C; Erinjeri, Joseph P; Maybody, Majid; Schöder, Heiko; Siegelbaum, Robert H; Sofocleous, Constantinos T; Deasy, Joseph O; Solomon, Stephen B; Humm, John L; Kirov, Assen S

    2015-04-01

    Core biopsies obtained using PET/CT guidance contain bound radiotracer and therefore provide information about tracer uptake in situ. Our goal was to develop a method for quantitative autoradiography of biopsy specimens (QABS), to use this method to correlate (18)F-FDG tracer uptake in situ with histopathology findings, and to briefly discuss its potential application. Twenty-seven patients referred for a PET/CT-guided biopsy of (18)F-FDG-avid primary or metastatic lesions in different locations consented to participate in this institutional review board-approved study, which complied with the Health Insurance Portability and Accountability Act. Autoradiography of biopsy specimens obtained using 5 types of needles was performed immediately after extraction. The response of autoradiography imaging plates was calibrated using dummy specimens with known activity obtained using 2 core-biopsy needle sizes. The calibration curves were used to quantify the activity along biopsy specimens obtained with these 2 needles and to calculate the standardized uptake value, SUVARG. Autoradiography images were correlated with histopathologic findings and fused with PET/CT images demonstrating the position of the biopsy needle within the lesion. Logistic regression analysis was performed to search for an SUVARG threshold distinguishing benign from malignant tissue in liver biopsy specimens. Pearson correlation between SUVARG of the whole biopsy specimen and average SUVPET over the voxels intersected by the needle in the fused PET/CT image was calculated. Activity concentrations were obtained using autoradiography for 20 specimens extracted with 18- and 20-gauge needles. The probability of finding malignancy in a specimen is greater than 50% (95% confidence) if SUVARG is greater than 7.3. For core specimens with preserved shape and orientation and in the absence of motion, one can achieve autoradiography, CT, and PET image registration with spatial accuracy better than 2 mm. The

  18. Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results

    PubMed Central

    Tonyushkina, Ksenia; Nichols, James H.

    2009-01-01

    Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy

  19. Spacecraft attitude determination accuracy from mission experience

    NASA Technical Reports Server (NTRS)

    Brasoveanu, D.; Hashmall, J.

    1994-01-01

    This paper summarizes a compilation of attitude determination accuracies attained by a number of satellites supported by the Goddard Space Flight Center Flight Dynamics Facility. The compilation is designed to assist future mission planners in choosing and placing attitude hardware and selecting the attitude determination algorithms needed to achieve given accuracy requirements. The major goal of the compilation is to indicate realistic accuracies achievable using a given sensor complement based on mission experience. It is expected that the use of actual spacecraft experience will make the study especially useful for mission design. A general description of factors influencing spacecraft attitude accuracy is presented. These factors include determination algorithms, inertial reference unit characteristics, and error sources that can affect measurement accuracy. Possible techniques for mitigating errors are also included. Brief mission descriptions are presented with the attitude accuracies attained, grouped by the sensor pairs used in attitude determination. The accuracies for inactive missions represent a compendium of missions report results, and those for active missions represent measurements of attitude residuals. Both three-axis and spin stabilized missions are included. Special emphasis is given to high-accuracy sensor pairs, such as two fixed-head star trackers (FHST's) and fine Sun sensor plus FHST. Brief descriptions of sensor design and mode of operation are included. Also included are brief mission descriptions and plots summarizing the attitude accuracy attained using various sensor complements.

  20. Ground Truth Sampling and LANDSAT Accuracy Assessment

    NASA Technical Reports Server (NTRS)

    Robinson, J. W.; Gunther, F. J.; Campbell, W. J.

    1982-01-01

    It is noted that the key factor in any accuracy assessment of remote sensing data is the method used for determining the ground truth, independent of the remote sensing data itself. The sampling and accuracy procedures developed for nuclear power plant siting study are described. The purpose of the sampling procedure was to provide data for developing supervised classifications for two study sites and for assessing the accuracy of that and the other procedures used. The purpose of the accuracy assessment was to allow the comparison of the cost and accuracy of various classification procedures as applied to various data types.

  1. Greater Biopsy Core Number Is Associated With Improved Biochemical Control in Patients Treated With Permanent Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bittner, Nathan; Merrick, Gregory S., E-mail: gmerrick@urologicresearchinstitute.or; Galbreath, Robert W.

    2010-11-15

    Purpose: Standard prostate biopsy schemes underestimate Gleason score in a significant percentage of cases. Extended biopsy improves diagnostic accuracy and provides more reliable prognostic information. In this study, we tested the hypothesis that greater biopsy core number should result in improved treatment outcome through better tailoring of therapy. Methods and Materials: From April 1995 to May 2006, 1,613 prostate cancer patients were treated with permanent brachytherapy. Patients were divided into five groups stratified by the number of prostate biopsy cores ({<=}6, 7-9, 10-12, 13-20, and >20 cores). Biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) were evaluatedmore » as a function of core number. Results: The median patient age was 66 years, and the median preimplant prostate-specific antigen was 6.5 ng/mL. The overall 10-year bPFS, CSS, and OS were 95.6%, 98.3%, and 78.6%, respectively. When bPFS was analyzed as a function of core number, the 10-year bPFS for patients with >20, 13-20, 10-12, 7-9 and {<=}6 cores was 100%, 100%, 98.3%, 95.8%, and 93.0% (p < 0.001), respectively. When evaluated by treatment era (1995-2000 vs. 2001-2006), the number of biopsy cores remained a statistically significant predictor of bPFS. On multivariate analysis, the number of biopsy cores was predictive of bPFS but did not predict for CSS or OS. Conclusion: Greater biopsy core number was associated with a statistically significant improvement in bPFS. Comprehensive regional sampling of the prostate may enhance diagnostic accuracy compared to a standard biopsy scheme, resulting in better tailoring of therapy.« less

  2. Required experimental accuracy to select between supersymmetrical models

    NASA Astrophysics Data System (ADS)

    Grellscheid, David

    2004-03-01

    We will present a method to decide a priori whether various supersymmetrical scenarios can be distinguished based on sparticle mass data alone. For each model, a scan over all free SUSY breaking parameters reveals the extent of that model's physically allowed region of sparticle-mass-space. Based on the geometrical configuration of these regions in mass-space, it is possible to obtain an estimate of the required accuracy of future sparticle mass measurements to distinguish between the models. We will illustrate this algorithm with an example. This talk is based on work done in collaboration with B C Allanach (LAPTH, Annecy) and F Quevedo (DAMTP, Cambridge).

  3. Test expectancy affects metacomprehension accuracy.

    PubMed

    Thiede, Keith W; Wiley, Jennifer; Griffin, Thomas D

    2011-06-01

    Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and practice tests. The purpose of the present study was to examine whether the accuracy metacognitive monitoring was affected by the nature of the test expected. Students (N= 59) were randomly assigned to one of two test expectancy groups (memory vs. inference). Then after reading texts, judging learning, completed both memory and inference tests. Test performance and monitoring accuracy were superior when students received the kind of test they had been led to expect rather than the unexpected test. Tests influence students' perceptions of what constitutes learning. Our findings suggest that this could affect how students prepare for tests and how they monitoring their own learning. ©2010 The British Psychological Society.

  4. Accuracy Analysis of Precise Point Positioning of Compass Navigation System Applied to Crustal Motion Monitoring

    NASA Astrophysics Data System (ADS)

    Wang, Yuebing

    2017-04-01

    Based on the observation data of Compass/GPSobserved at five stations, time span from July 1, 2014 to June 30, 2016. UsingPPP positioning model of the PANDA software developed by Wuhan University,Analyzedthe positioning accuracy of single system and Compass/GPS integrated resolving, and discussed the capability of Compass navigation system in crustal motion monitoring. The results showed that the positioning accuracy in the east-west directionof the Compass navigation system is lower than the north-south direction (the positioning accuracy de 3 times RMS), in general, the positioning accuracyin the horizontal direction is about 1 2cm and the vertical direction is about 5 6cm. The GPS positioning accuracy in the horizontal direction is better than 1cm and the vertical direction is about 1 2cm. The accuracy of Compass/GPS integrated resolving is quite to GPS. It is worth mentioning that although Compass navigation system precision point positioning accuracy is lower than GPS, two sets of velocity fields obtained by using the Nikolaidis (2002) model to analyze the Compass and GPS time series results respectively, the results showed that the maximum difference of the two sets of velocity field in horizontal directions is 1.8mm/a. The Compass navigation system can now be used to monitor the crustal movement of the large deformation area, based on the velocity field in horizontal direction.

  5. Accuracy Study of the Space-Time CE/SE Method for Computational Aeroacoustics Problems Involving Shock Waves

    NASA Technical Reports Server (NTRS)

    Wang, Xiao Yen; Chang, Sin-Chung; Jorgenson, Philip C. E.

    1999-01-01

    The space-time conservation element and solution element(CE/SE) method is used to study the sound-shock interaction problem. The order of accuracy of numerical schemes is investigated. The linear model problem.govemed by the 1-D scalar convection equation, sound-shock interaction problem governed by the 1-D Euler equations, and the 1-D shock-tube problem which involves moving shock waves and contact surfaces are solved to investigate the order of accuracy of numerical schemes. It is concluded that the accuracy of the CE/SE numerical scheme with designed 2nd-order accuracy becomes 1st order when a moving shock wave exists. However, the absolute error in the CE/SE solution downstream of the shock wave is on the same order as that obtained using a fourth-order accurate essentially nonoscillatory (ENO) scheme. No special techniques are used for either high-frequency low-amplitude waves or shock waves.

  6. Intrapersonal Variability in Negative Affect as a Moderator of Accuracy and Bias in Interpersonal Perception.

    PubMed

    Sadikaj, Gentiana; Moskowitz, D S; Zuroff, David C

    2015-08-01

    High intrapersonal variability has frequently been found to be related to poor personal and interpersonal outcomes. Little research has examined processes by which intrapersonal variability influences outcomes. This study explored the relation of intrapersonal variability in negative affect (negative affect flux) to accuracy and bias in the perception of a romantic partner's quarrelsome behavior. A sample of 93 cohabiting couples participated in a study using an event-contingent recording (ECR) methodology in which they reported their negative affect, quarrelsome behavior, and perception of their partner's quarrelsome behavior in interactions with each other during a 20-day period. Negative affect flux was operationalized as the within-person standard deviation of negative affect scores across couple interactions. Findings suggested that participants were both accurate in tracking changes in their partner's quarrelsome behavior and biased in assuming their partner's quarrelsome behavior mirrored their own quarrelsome behavior. Negative affect flux moderated both accuracy and bias of assumed similarity such that participants with higher flux manifested both greater tracking accuracy and larger bias of assumed similarity. Negative affect flux may be related to enhanced vigilance to close others' negative behavior, which may explain higher tracking accuracy and propensity to rely on a person's own negative behavior as a means of judging others' negative behavior. These processes may augment these individuals' negative interpersonal behavior, enhance cycles of negative social interactions, and lead to poor intrapersonal and interpersonal outcomes.

  7. Effect of Kinesiotape Applications on Ball Velocity and Accuracy in Amateur Soccer and Handball.

    PubMed

    Müller, Carsten; Brandes, Mirko

    2015-12-22

    Evidence supporting performance enhancing effects of kinesiotape in sports is missing. The aims of this study were to evaluate effects of kinesiotape applications with regard to shooting and throwing performance in 26 amateur soccer and 32 handball players, and to further investigate if these effects were influenced by the players' level of performance. Ball speed as the primary outcome and accuracy of soccer kicks and handball throws were analyzed with and without kinesiotape by means of radar units and video recordings. The application of kinesiotapes significantly increased ball speed in soccer by 1.4 km/h (p=0.047) and accuracy with a lesser distance from the target by -6.9 cm (p=0.039). Ball velocity in handball throws also significantly increased by 1.2 km/h (p=0.013), while accuracy was deteriorated with a greater distance from the target by 3.4 cm (p=0.005). Larger effects with respect to ball speed were found in players with a lower performance level in kicking (1.7 km/h, p=0.028) and throwing (1.8 km/h, p=0.001) compared with higher level soccer and handball players (1.2 km/h, p=0.346 and 0.5 km/h, p=0.511, respectively). In conclusion, the applications of kinesiotape used in this study might have beneficial effects on performance in amateur soccer, but the gain in ball speed in handball is counteracted by a significant deterioration of accuracy. Subgroup analyses indicate that kinesiotape may yield larger effects on ball velocity in athletes with lower kicking and throwing skills.

  8. Propagation of measurement accuracy to biomass soft-sensor estimation and control quality.

    PubMed

    Steinwandter, Valentin; Zahel, Thomas; Sagmeister, Patrick; Herwig, Christoph

    2017-01-01

    In biopharmaceutical process development and manufacturing, the online measurement of biomass and derived specific turnover rates is a central task to physiologically monitor and control the process. However, hard-type sensors such as dielectric spectroscopy, broth fluorescence, or permittivity measurement harbor various disadvantages. Therefore, soft-sensors, which use measurements of the off-gas stream and substrate feed to reconcile turnover rates and provide an online estimate of the biomass formation, are smart alternatives. For the reconciliation procedure, mass and energy balances are used together with accuracy estimations of measured conversion rates, which were so far arbitrarily chosen and static over the entire process. In this contribution, we present a novel strategy within the soft-sensor framework (named adaptive soft-sensor) to propagate uncertainties from measurements to conversion rates and demonstrate the benefits: For industrially relevant conditions, hereby the error of the resulting estimated biomass formation rate and specific substrate consumption rate could be decreased by 43 and 64 %, respectively, compared to traditional soft-sensor approaches. Moreover, we present a generic workflow to determine the required raw signal accuracy to obtain predefined accuracies of soft-sensor estimations. Thereby, appropriate measurement devices and maintenance intervals can be selected. Furthermore, using this workflow, we demonstrate that the estimation accuracy of the soft-sensor can be additionally and substantially increased.

  9. Influence of time of placement of investments for burnout and the type of rings being used on the casting accuracy.

    PubMed

    Shah, Shabir A; Naqash, Talib Amin; Padmanabhan, T V; Subramanium; Lambodaran; Nazir, Shazana

    2014-03-01

    The sole objective of casting procedure is to provide a metallic duplication of missing tooth structure, with as great accuracy as possible. The ability to produce well fitting castings require strict adherence to certain fundamentals. A study was undertaken to comparatively evaluate the effect on casting accuracy by subjecting the invested wax patterns to burnout after different time intervals. The effect on casting accuracy using metal ring into a pre heated burnout furnace and using split ring was also carried. The readings obtained were tabulated and subjected to statistical analysis.

  10. 5 CFR 630.1210 - Greater leave entitlements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND LEAVE Family and Medical Leave § 630.1210 Greater leave entitlements. (a) An agency shall comply... greater family or medical leave entitlements to employees than those provided under this subpart. Nothing...

  11. Feature instructions improve face-matching accuracy

    PubMed Central

    Bindemann, Markus

    2018-01-01

    Identity comparisons of photographs of unfamiliar faces are prone to error but important for applied settings, such as person identification at passport control. Finding techniques to improve face-matching accuracy is therefore an important contemporary research topic. This study investigated whether matching accuracy can be improved by instruction to attend to specific facial features. Experiment 1 showed that instruction to attend to the eyebrows enhanced matching accuracy for optimized same-day same-race face pairs but not for other-race faces. By contrast, accuracy was unaffected by instruction to attend to the eyes, and declined with instruction to attend to ears. Experiment 2 replicated the eyebrow-instruction improvement with a different set of same-race faces, comprising both optimized same-day and more challenging different-day face pairs. These findings suggest that instruction to attend to specific features can enhance face-matching accuracy, but feature selection is crucial and generalization across face sets may be limited. PMID:29543822

  12. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions.

    PubMed

    Baig, Mirza R; Buzayan, Muaiyed M; Yunus, Norsiah

    2018-05-01

    The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts. Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05. The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05). The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions. © 2018 John Wiley & Sons Australia, Ltd.

  13. MAPPING SPATIAL THEMATIC ACCURACY WITH FUZZY SETS

    EPA Science Inventory

    Thematic map accuracy is not spatially homogenous but variable across a landscape. Properly analyzing and representing spatial pattern and degree of thematic map accuracy would provide valuable information for using thematic maps. However, current thematic map accuracy measures (...

  14. Influence of simulation parameters on the speed and accuracy of Monte Carlo calculations using PENEPMA

    NASA Astrophysics Data System (ADS)

    Llovet, X.; Salvat, F.

    2018-01-01

    The accuracy of Monte Carlo simulations of EPMA measurements is primarily determined by that of the adopted interaction models and atomic relaxation data. The code PENEPMA implements the most reliable general models available, and it is known to provide a realistic description of electron transport and X-ray emission. Nonetheless, efficiency (i.e., the simulation speed) of the code is determined by a number of simulation parameters that define the details of the electron tracking algorithm, which may also have an effect on the accuracy of the results. In addition, to reduce the computer time needed to obtain X-ray spectra with a given statistical accuracy, PENEPMA allows the use of several variance-reduction techniques, defined by a set of specific parameters. In this communication we analyse and discuss the effect of using different values of the simulation and variance-reduction parameters on the speed and accuracy of EPMA simulations. We also discuss the effectiveness of using multi-core computers along with a simple practical strategy implemented in PENEPMA.

  15. SLOWLY REPEATED EVOKED PAIN (SREP) AS A MARKER OF CENTRAL SENSITIZATION IN FIBROMYALGIA: DIAGNOSTIC ACCURACY AND RELIABILITY IN COMPARISON WITH TEMPORAL SUMMATION OF PAIN.

    PubMed

    de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A

    2018-05-01

    This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.

  16. Test Expectancy Affects Metacomprehension Accuracy

    ERIC Educational Resources Information Center

    Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.

    2011-01-01

    Background: Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and…

  17. Spectroscopy of H3+ based on a new high-accuracy global potential energy surface.

    PubMed

    Polyansky, Oleg L; Alijah, Alexander; Zobov, Nikolai F; Mizus, Irina I; Ovsyannikov, Roman I; Tennyson, Jonathan; Lodi, Lorenzo; Szidarovszky, Tamás; Császár, Attila G

    2012-11-13

    The molecular ion H(3)(+) is the simplest polyatomic and poly-electronic molecular system, and its spectrum constitutes an important benchmark for which precise answers can be obtained ab initio from the equations of quantum mechanics. Significant progress in the computation of the ro-vibrational spectrum of H(3)(+) is discussed. A new, global potential energy surface (PES) based on ab initio points computed with an average accuracy of 0.01 cm(-1) relative to the non-relativistic limit has recently been constructed. An analytical representation of these points is provided, exhibiting a standard deviation of 0.097 cm(-1). Problems with earlier fits are discussed. The new PES is used for the computation of transition frequencies. Recently measured lines at visible wavelengths combined with previously determined infrared ro-vibrational data show that an accuracy of the order of 0.1 cm(-1) is achieved by these computations. In order to achieve this degree of accuracy, relativistic, adiabatic and non-adiabatic effects must be properly accounted for. The accuracy of these calculations facilitates the reassignment of some measured lines, further reducing the standard deviation between experiment and theory.

  18. Limits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials.

    PubMed

    Schrangl, Patrick; Reiterer, Florian; Heinemann, Lutz; Freckmann, Guido; Del Re, Luigi

    2018-05-18

    Systems for continuous glucose monitoring (CGM) are evolving quickly, and the data obtained are expected to become the basis for clinical decisions for many patients with diabetes in the near future. However, this requires that their analytical accuracy is sufficient. This accuracy is usually determined with clinical studies by comparing the data obtained by the given CGM system with blood glucose (BG) point measurements made with a so-called reference method. The latter is assumed to indicate the correct value of the target quantity. Unfortunately, due to the nature of the clinical trials and the approach used, such a comparison is subject to several effects which may lead to misleading results. While some reasons for the differences between the values obtained with CGM and BG point measurements are relatively well-known (e.g., measurement in different body compartments), others related to the clinical study protocols are less visible, but also quite important. In this review, we present a general picture of the topic as well as tools which allow to correct or at least to estimate the uncertainty of measures of CGM system performance.

  19. Meta-Accuracy and Relationship Quality: Weighing the Costs and Benefits of Knowing What People Really Think About You

    PubMed Central

    Carlson, Erika N.

    2016-01-01

    People use metaperceptions, or their beliefs about how other people perceive them, to initiate and maintain social bonds. Are accurate metaperceptions associated with higher quality relationships? In four studies, the current research answers this question but considers the possibility that the self might not experience the same relational benefits of accurate metaperceptions, or meta-accuracy, as the people who form judgments about the self. For example, people tend to like individuals who have accurate self-perceptions, yet individuals tend to enjoy their own relationships more with people they believe see them in desirable ways. To test whether meta-accuracy is linked to relationship quality and whether this link differs for the self and others, meta-accuracy for personality traits as well as metaperceiver- and judge-reported relationship quality were assessed among new acquaintances (N = 184), peers (N = 228), friends (N = 273), and romantic partners (N = 401). Results suggested that judges enjoyed relationships more with metaperceivers who knew the impression they made, regardless of whether judges’ impressions were desirable (i.e., positive or self-verifying). Initial meta-accuracy also predicted greater relationship quality over time, suggesting that accurate metaperceptions have positive effects on relationships. In contrast, rather than enjoying relationships more when they were accurate, metaperceivers enjoyed relationships more when they believed judges perceived them in positive or self-verifying ways. Thus, meta-accuracy seems to be a virtue in the eyes of judges, but metaperceivers do not seem to reap the same benefits of knowing what others really think. Implications for improving meta-accuracy are discussed. PMID:27337137

  20. Restoration of the ASCA Source Position Accuracy

    NASA Astrophysics Data System (ADS)

    Gotthelf, E. V.; Ueda, Y.; Fujimoto, R.; Kii, T.; Yamaoka, K.

    2000-11-01

    We present a calibration of the absolute pointing accuracy of the Advanced Satellite for Cosmology and Astrophysics (ASCA) which allows us to compensate for a large error (up to 1') in the derived source coordinates. We parameterize a temperature dependent deviation of the attitude solution which is responsible for this error. By analyzing ASCA coordinates of 100 bright active galactic nuclei, we show that it is possible to reduce the uncertainty in the sky position for any given observation by a factor of 4. The revised 90% error circle radius is then 12", consistent with preflight specifications, effectively restoring the full ASCA pointing accuracy. Herein, we derive an algorithm which compensates for this attitude error and present an internet-based table to be used to correct post facto the coordinate of all ASCA observations. While the above error circle is strictly applicable to data taken with the on-board Solid-state Imaging Spectrometers (SISs), similar coordinate corrections are derived for data obtained with the Gas Imaging Spectrometers (GISs), which, however, have additional instrumental uncertainties. The 90% error circle radius for the central 20' diameter of the GIS is 24". The large reduction in the error circle area for the two instruments offers the opportunity to greatly enhance the search for X-ray counterparts at other wavelengths. This has important implications for current and future ASCA source catalogs and surveys.

  1. Accuracy Assessment of the GLOBELAND30 Dataset in Jiangxi Province

    NASA Astrophysics Data System (ADS)

    Ren, H.; Cai, G.; Zhao, G.; Li, Z.

    2018-04-01

    The Globeland30 dataset is the most highly spatial resolution global land cover mapping product, which developed by the National Geomatics Center of China (NGCC) in 2015. It plays a significant role in environmental monitoring, climate change, and ecosystem assessment, etc. In this study, Jiangxi province was selected as our study area, the 1 : 100000 land use data in 2010 was employed as the reference data. We aim to examine the accuracy of the Globeland30 from three methods, including area error analysis, shape consistency analysis and confusion matrix. The results show as follows: The land cover types in the study area are primarily occupied by the cultivated land and forest, and secondarily by grassland, water bodies and artificial surfaces. The area error of cultivated land, forest and water bodies are all less than 13 %; The general conformance of the shape consistency reaches to 67 %, but the shape consistency of every land type differs to a large degree, the best shape consistency of forests is up to 75 %; The confusion matrix is obtained in two cases of different class boundary with buffer and no buffer area. It is found that the overall accuracy and kappa coefficient of GlobeLand30 are improved with buffer area. The value of overall accuracy is higher than 78 %, the value of kappa coefficient is higher than 0.52.

  2. Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

    PubMed

    Shokri, Abbas; Eskandarloo, Amir; Norouzi, Marouf; Poorolajal, Jalal; Majidi, Gelareh; Aliyaly, Alireza

    2018-03-01

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

  3. Digital versus conventional implant impressions for edentulous patients: accuracy outcomes.

    PubMed

    Papaspyridakos, Panos; Gallucci, German O; Chen, Chun-Jung; Hanssen, Stijn; Naert, Ignace; Vandenberghe, Bart

    2016-04-01

    To compare the accuracy of digital and conventional impression techniques for completely edentulous patients and to determine the effect of different variables on the accuracy outcomes. A stone cast of an edentulous mandible with five implants was fabricated to serve as master cast (control) for both implant- and abutment-level impressions. Digital impressions (n = 10) were taken with an intraoral optical scanner (TRIOS, 3shape, Denmark) after connecting polymer scan bodies. For the conventional polyether impressions of the master cast, a splinted and a non-splinted technique were used for implant-level and abutment-level impressions (4 cast groups, n = 10 each). Master casts and conventional impression casts were digitized with an extraoral high-resolution scanner (IScan D103i, Imetric, Courgenay, Switzerland) to obtain digital volumes. Standard tessellation language (STL) datasets from the five groups of digital and conventional impressions were superimposed with the STL dataset from the master cast to assess the 3D (global) deviations. To compare the master cast with digital and conventional impressions at the implant level, analysis of variance (ANOVA) and Scheffe's post hoc test was used, while Wilcoxon's rank-sum test was used for testing the difference between abutment-level conventional impressions. Significant 3D deviations (P < 0.001) were found between Group II (non-splinted, implant level) and control. No significant differences were found between Groups I (splinted, implant level), III (digital, implant level), IV (splinted, abutment level), and V (non-splinted, abutment level) compared with the control. Implant angulation up to 15° did not affect the 3D accuracy of implant impressions (P > 0.001). Digital implant impressions are as accurate as conventional implant impressions. The splinted, implant-level impression technique is more accurate than the non-splinted one for completely edentulous patients, whereas there was no difference in the accuracy

  4. Insensitivity of the octahedral spherical hohlraum to power imbalance, pointing accuracy, and assemblage accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huo, Wen Yi; Zhao, Yiqing; Zheng, Wudi

    2014-11-15

    The random radiation asymmetry in the octahedral spherical hohlraum [K. Lan et al., Phys. Plasmas 21, 0 10704 (2014)] arising from the power imbalance, pointing accuracy of laser quads, and the assemblage accuracy of capsule is investigated by using the 3-dimensional view factor model. From our study, for the spherical hohlraum, the random radiation asymmetry arising from the power imbalance of the laser quads is about half of that in the cylindrical hohlraum; the random asymmetry arising from the pointing error is about one order lower than that in the cylindrical hohlraum; and the random asymmetry arising from the assemblage errormore » of capsule is about one third of that in the cylindrical hohlraum. Moreover, the random radiation asymmetry in the spherical hohlraum is also less than the amount in the elliptical hohlraum. The results indicate that the spherical hohlraum is more insensitive to the random variations than the cylindrical hohlraum and the elliptical hohlraum. Hence, the spherical hohlraum can relax the requirements to the power imbalance and pointing accuracy of laser facility and the assemblage accuracy of capsule.« less

  5. Commissioning Procedures for Mechanical Precision and Accuracy in a Dedicated LINAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ballesteros-Zebadua, P.; Larrga-Gutierrez, J. M.; Garcia-Garduno, O. A.

    2008-08-11

    Mechanical precision measurements are fundamental procedures for the commissioning of a dedicated LINAC. At our Radioneurosurgery Unit, these procedures can be suitable as quality assurance routines that allow the verification of the equipment geometrical accuracy and precision. In this work mechanical tests were performed for gantry and table rotation, obtaining mean associated uncertainties of 0.3 mm and 0.71 mm, respectively. Using an anthropomorphic phantom and a series of localized surface markers, isocenter accuracy showed to be smaller than 0.86 mm for radiosurgery procedures and 0.95 mm for fractionated treatments with mask. All uncertainties were below tolerances. The highest contribution tomore » mechanical variations is due to table rotation, so it is important to correct variations using a localization frame with printed overlays. Mechanical precision knowledge would allow to consider the statistical errors in the treatment planning volume margins.« less

  6. Privacy-Preserving Accountable Accuracy Management Systems (PAAMS)

    NASA Astrophysics Data System (ADS)

    Thomas, Roshan K.; Sandhu, Ravi; Bertino, Elisa; Arpinar, Budak; Xu, Shouhuai

    We argue for the design of “Privacy-preserving Accountable Accuracy Management Systems (PAAMS)”. The designs of such systems recognize from the onset that accuracy, accountability, and privacy management are intertwined. As such, these systems have to dynamically manage the tradeoffs between these (often conflicting) objectives. For example, accuracy in such systems can be improved by providing better accountability links between structured and unstructured information. Further, accuracy may be enhanced if access to private information is allowed in controllable and accountable ways. Our proposed approach involves three key elements. First, a model to link unstructured information such as that found in email, image and document repositories with structured information such as that in traditional databases. Second, a model for accuracy management and entity disambiguation by proactively preventing, detecting and tracing errors in information bases. Third, a model to provide privacy-governed operation as accountability and accuracy are managed.

  7. Tracking accuracy assessment for concentrator photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Norton, Matthew S. H.; Anstey, Ben; Bentley, Roger W.; Georghiou, George E.

    2010-10-01

    The accuracy to which a concentrator photovoltaic (CPV) system can track the sun is an important parameter that influences a number of measurements that indicate the performance efficiency of the system. This paper presents work carried out into determining the tracking accuracy of a CPV system, and illustrates the steps involved in gaining an understanding of the tracking accuracy. A Trac-Stat SL1 accuracy monitor has been used in the determination of pointing accuracy and has been integrated into the outdoor CPV module test facility at the Photovoltaic Technology Laboratories in Nicosia, Cyprus. Results from this work are provided to demonstrate how important performance indicators may be presented, and how the reliability of results is improved through the deployment of such accuracy monitors. Finally, recommendations on the use of such sensors are provided as a means to improve the interpretation of real outdoor performance.

  8. Analysis of 3d Building Models Accuracy Based on the Airborne Laser Scanning Point Clouds

    NASA Astrophysics Data System (ADS)

    Ostrowski, W.; Pilarska, M.; Charyton, J.; Bakuła, K.

    2018-05-01

    Creating 3D building models in large scale is becoming more popular and finds many applications. Nowadays, a wide term "3D building models" can be applied to several types of products: well-known CityGML solid models (available on few Levels of Detail), which are mainly generated from Airborne Laser Scanning (ALS) data, as well as 3D mesh models that can be created from both nadir and oblique aerial images. City authorities and national mapping agencies are interested in obtaining the 3D building models. Apart from the completeness of the models, the accuracy aspect is also important. Final accuracy of a building model depends on various factors (accuracy of the source data, complexity of the roof shapes, etc.). In this paper the methodology of inspection of dataset containing 3D models is presented. The proposed approach check all building in dataset with comparison to ALS point clouds testing both: accuracy and level of details. Using analysis of statistical parameters for normal heights for reference point cloud and tested planes and segmentation of point cloud provides the tool that can indicate which building and which roof plane in do not fulfill requirement of model accuracy and detail correctness. Proposed method was tested on two datasets: solid and mesh model.

  9. An assessment of the direction-finding accuracy of bat biosonar beampatterns.

    PubMed

    Gilani, Uzair S; Müller, Rolf

    2016-02-01

    In the biosonar systems of bats, emitted acoustic energy and receiver sensitivity are distributed over direction and frequency through beampattern functions that have diverse and often complicated geometries. This complexity could be used by the animals to determine the direction of incoming sounds based on spectral signatures. The present study has investigated how well bat biosonar beampatterns are suited for direction finding using a measure of the smallest estimator variance that is possible for a given direction [Cramér-Rao lower bound (CRLB)]. CRLB values were estimated for numerical beampattern estimates derived from 330 individual shape samples, 157 noseleaves (used for emission), and 173 outer ears (pinnae). At an assumed 60 dB signal-to-noise ratio, the average value of the CRLB was 3.9°, which is similar to previous behavioral findings. Distribution for the CRLBs in individual beampatterns had a positive skew indicating the existence of regions where a given beampattern does not support a high accuracy. The highest supported accuracies were for direction finding in elevation (with the exception of phyllostomid emission patterns). No large, obvious differences in the CRLB (greater 2° in the mean) were found between the investigated major taxonomic groups, suggesting that different bat species have access to similar direction-finding information.

  10. The availability of prior ECGs improves paramedic accuracy in recognizing ST-segment elevation myocardial infarction.

    PubMed

    O'Donnell, Daniel; Mancera, Mike; Savory, Eric; Christopher, Shawn; Schaffer, Jason; Roumpf, Steve

    2015-01-01

    Early and accurate identification of ST-elevation myocardial infarction (STEMI) by prehospital providers has been shown to significantly improve door to balloon times and improve patient outcomes. Previous studies have shown that paramedic accuracy in reading 12 lead ECGs can range from 86% to 94%. However, recent studies have demonstrated that accuracy diminishes for the more uncommon STEMI presentations (e.g. lateral). Unlike hospital physicians, paramedics rarely have the ability to review previous ECGs for comparison. Whether or not a prior ECG can improve paramedic accuracy is not known. The availability of prior ECGs improves paramedic accuracy in ECG interpretation. 130 paramedics were given a single clinical scenario. Then they were randomly assigned 12 computerized prehospital ECGs, 6 with and 6 without an accompanying prior ECG. All ECGs were obtained from a local STEMI registry. For each ECG paramedics were asked to determine whether or not there was a STEMI and to rate their confidence in their interpretation. To determine if the old ECGs improved accuracy we used a mixed effects logistic regression model to calculate p-values between the control and intervention. The addition of a previous ECG improved the accuracy of identifying STEMIs from 75.5% to 80.5% (p=0.015). A previous ECG also increased paramedic confidence in their interpretation (p=0.011). The availability of previous ECGs improves paramedic accuracy and enhances their confidence in interpreting STEMIs. Further studies are needed to evaluate this impact in a clinical setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Accuracy of a new real-time continuous glucose monitoring algorithm.

    PubMed

    Keenan, D Barry; Cartaya, Raymond; Mastrototaro, John J

    2010-01-01

    Through minimally invasive sensor-based continuous glucose monitoring (CGM), individuals can manage their blood glucose (BG) levels more aggressively, thereby improving their hemoglobin A1c level, while reducing the risk of hypoglycemia. Tighter glycemic control through CGM, however, requires an accurate glucose sensor and calibration algorithm with increased performance at lower BG levels. Sensor and BG measurements for 72 adult and adolescent subjects were obtained during the course of a 26-week multicenter study evaluating the efficacy of the Paradigm REAL-Time (PRT) sensor-augmented pump system (Medtronic Diabetes, Northridge, CA) in an outpatient setting. Subjects in the study arm performed at least four daily finger stick measurements. A retrospective analysis of the data set was performed to evaluate a new calibration algorithm utilized in the Paradigm Veo insulin pump (Medtronic Diabetes) and to compare these results to performance metrics calculated for the PRT. A total of N = 7193 PRT sensor downloads for 3 days of use, as well as 90,472 temporally and nonuniformly paired data points (sensor and meter values), were evaluated, with 5841 hypoglycemic and 15,851 hyperglycemic events detected through finger stick measurements. The Veo calibration algorithm decreased the overall mean absolute relative difference by greater than 0.25 to 15.89%, with hypoglycemia sensitivity increased from 54.9% in the PRT to 82.3% in the Veo (90.5% with predictive alerts); however, hyperglycemia sensitivity was decreased only marginally from 86% in the PRT to 81.7% in the Veo. The Veo calibration algorithm, with sensor error reduced significantly in the 40- to 120-mg/dl range, improves hypoglycemia detection, while retaining accuracy at high glucose levels. 2010 Diabetes Technology Society.

  12. Length and Geometric Patterns of the Greater Palatine Canal Observed in Cone Beam Computed Tomography

    PubMed Central

    Howard-Swirzinski, Karen; Edwards, Paul C.; Saini, Tarnjit S.; Norton, Neil S.

    2010-01-01

    The greater palatine canal is an important anatomical structure that is often utilized as a pathway for infiltration of local anesthesia to affect sensation and hemostasis. Increased awareness of the length and anatomic variation in the anatomy of this structure is important when performing surgical procedures in this area (e.g., placement of osseointegrated dental implants). We examined the anatomy of the greater palatine canal using data obtained from CBCT scans of 500 subjects. Both right and left canals were viewed (N = 1000) in coronal and sagittal planes, and their paths and lengths determined. The average length of the greater palatine canal was 29 mm (±3 mm), with a range from 22 to 40 mm. Coronally, the most common anatomic pattern consisted of the canal traveling inferior-laterally for a distance then directly inferior for the remainder (43.3%). In the sagittal view, the canal traveled most frequently at an anterior-inferior angle (92.9%). PMID:20871845

  13. Assessing risk of reoffending in adolescents who have committed a sexual offense: the accuracy of clinical judgments after completion of risk assessment instruments.

    PubMed

    Elkovitch, Natasha; Viljoen, Jodi L; Scalora, Mario J; Ullman, Daniel

    2008-01-01

    As courts often rely on clinicians when differentiating between sexually abusive youth at a low versus high risk of reoffense, understanding factors that contribute to accuracy in assessment of risk is imperative. The present study built on existing research by examining (1) the accuracy of clinical judgments of risk made after completing risk assessment instruments, (2) whether instrument-informed clinical judgments made with a high degree of confidence are associated with greater accuracy, and (3) the risk assessment instruments and subscales most predictive of clinical judgments. Raters assessed each youth's (n = 166) risk of reoffending after completing the SAVRY and J-SOAP-II. Raters were not able to predict detected cases of either sexual recidivism or nonsexual violent recidivism above chance, and a high degree of rater confidence was not associated with higher levels of accuracy. Total scores on the J-SOAP-II were predictive of instrument-informed clinical judgments of sexual risk, and total scores on the SAVRY of nonsexual risk.

  14. Assessing and Ensuring GOES-R Magnetometer Accuracy

    NASA Technical Reports Server (NTRS)

    Kronenwetter, Jeffrey; Carter, Delano R.; Todirita, Monica; Chu, Donald

    2016-01-01

    The GOES-R magnetometer accuracy requirement is 1.7 nanoteslas (nT). During quiet times (100 nT), accuracy is defined as absolute mean plus 3 sigma. During storms (300 nT), accuracy is defined as absolute mean plus 2 sigma. To achieve this, the sensor itself has better than 1 nT accuracy. Because zero offset and scale factor drift over time, it is also necessary to perform annual calibration maneuvers. To predict performance, we used covariance analysis and attempted to corroborate it with simulations. Although not perfect, the two generally agree and show the expected behaviors. With the annual calibration regimen, these predictions suggest that the magnetometers will meet their accuracy requirements.

  15. Noncompliance in people living with HIV: accuracy of defining characteristics of the nursing diagnosis 1

    PubMed Central

    da Silva, Richardson Augusto Rosendo; Costa, Mayara Mirna do Nascimento; de Souza, Vinicius Lino; da Silva, Bárbara Coeli Oliveira; Costa, Cristiane da Silva; de Andrade, Itaísa Fernandes Cardoso

    2017-01-01

    ABSTRACT Objective: to evaluate the accuracy of the defining characteristics of the NANDA International nursing diagnosis, noncompliance, in people with HIV. Method: study of diagnostic accuracy, performed in two stages. In the first stage, 113 people with HIV from a hospital of infectious diseases in the Northeast of Brazil were assessed for identification of clinical indicators of noncompliance. In the second, the defining characteristics were evaluated by six specialist nurses, analyzing the presence or absence of the diagnosis. For accuracy of the clinical indicators, the specificity, sensitivity, predictive values and likelihood ratios were measured. Results: the presence of the noncompliance diagnosis was shown in 69% (n=78) of people with HIV. The most sensitive indicator was, missing of appointments (OR: 28.93, 95% CI: 1.112-2.126, p = 0.002). On the other hand, nonadherence behavior (OR: 15.00, 95% CI: 1.829-3.981, p = 0.001) and failure to meet outcomes (OR: 13.41; 95% CI: 1.272-2.508; P = 0.003) achieved higher specificity. Conclusion: the most accurate defining characteristics were nonadherence behavior, missing of appointments, and failure to meet outcomes. Thus, in the presence of these, the nurse can identify, with greater security, the diagnosis studied. PMID:29091125

  16. Accuracy of self-reports of fecal occult blood tests and test results among individuals in the carpentry trade.

    PubMed

    Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F

    2003-11-01

    Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.

  17. Assessing the accuracy of TDR-based water leak detection system

    NASA Astrophysics Data System (ADS)

    Fatemi Aghda, S. M.; GanjaliPour, K.; Nabiollahi, K.

    2018-03-01

    The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years. In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases. The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points) showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points.

  18. Voice Identification: Levels-of-Processing and the Relationship between Prior Description Accuracy and Recognition Accuracy.

    ERIC Educational Resources Information Center

    Walter, Todd J.

    A study examined whether a person's ability to accurately identify a voice is influenced by factors similar to those proposed by the Supreme Court for eyewitness identification accuracy. In particular, the Supreme Court has suggested that a person's prior description accuracy of a suspect, degree of attention to a suspect, and confidence in…

  19. Examination of the Position Accuracy of Implant Abutments Reproduced by Intra-Oral Optical Impression

    PubMed Central

    Odaira, Chikayuki; Kobayashi, Takuya; Kondo, Hisatomo

    2016-01-01

    An impression technique called optical impression using intraoral scanner has attracted attention in digital dentistry. This study aimed to evaluate the accuracy of the optical impression, comparing a virtual model reproduced by an intraoral scanner to a working cast made by conventional silicone impression technique. Two implants were placed on a master model. Working casts made of plaster were fabricated from the master model by silicone impression. The distance between the ball abutments and the angulation between the healing abutments of 5 mm and 7 mm height at master model were measured using Computer Numerical Control Coordinate Measuring Machine (CNCCMM) as control. Working casts were then measured using CNCCMM, and virtual models via stereo lithography data of master model were measured by a three-dimensional analyzing software. The distance between ball abutments of the master model was 9634.9 ± 1.2 μm. The mean values of trueness of the Lava COS and working casts were 64.5 μm and 22.5 μm, respectively, greater than that of control. The mean of precision values of the Lava COS and working casts were 15.6 μm and 13.5 μm, respectively. In the case of a 5-mm-height healing abutment, mean angulation error of the Lava COS was greater than that of the working cast, resulting in significant differences in trueness and precision. However, in the case of a 7-mm-height abutment, mean angulation errors of the Lava COS and the working cast were not significantly different in trueness and precision. Therefore, distance errors of the optical impression were slightly greater than those of conventional impression. Moreover, the trueness and precision of angulation error could be improved in the optical impression using longer healing abutments. In the near future, the development of information technology could enable improvement in the accuracy of the optical impression with intraoral scanners. PMID:27706225

  20. Improved accuracy for finite element structural analysis via a new integrated force method

    NASA Technical Reports Server (NTRS)

    Patnaik, Surya N.; Hopkins, Dale A.; Aiello, Robert A.; Berke, Laszlo

    1992-01-01

    A comparative study was carried out to determine the accuracy of finite element analyses based on the stiffness method, a mixed method, and the new integrated force and dual integrated force methods. The numerical results were obtained with the following software: MSC/NASTRAN and ASKA for the stiffness method; an MHOST implementation method for the mixed method; and GIFT for the integrated force methods. The results indicate that on an overall basis, the stiffness and mixed methods present some limitations. The stiffness method generally requires a large number of elements in the model to achieve acceptable accuracy. The MHOST method tends to achieve a higher degree of accuracy for course models than does the stiffness method implemented by MSC/NASTRAN and ASKA. The two integrated force methods, which bestow simultaneous emphasis on stress equilibrium and strain compatibility, yield accurate solutions with fewer elements in a model. The full potential of these new integrated force methods remains largely unexploited, and they hold the promise of spawning new finite element structural analysis tools.

  1. Investigation of the reconstruction accuracy of guided wave tomography using full waveform inversion

    NASA Astrophysics Data System (ADS)

    Rao, Jing; Ratassepp, Madis; Fan, Zheng

    2017-07-01

    Guided wave tomography is a promising tool to accurately determine the remaining wall thicknesses of corrosion damages, which are among the major concerns for many industries. Full Waveform Inversion (FWI) algorithm is an attractive guided wave tomography method, which uses a numerical forward model to predict the waveform of guided waves when propagating through corrosion defects, and an inverse model to reconstruct the thickness map from the ultrasonic signals captured by transducers around the defect. This paper discusses the reconstruction accuracy of the FWI algorithm on plate-like structures by using simulations as well as experiments. It was shown that this algorithm can obtain a resolution of around 0.7 wavelengths for defects with smooth depth variations from the acoustic modeling data, and about 1.5-2 wavelengths from the elastic modeling data. Further analysis showed that the reconstruction accuracy is also dependent on the shape of the defect. It was demonstrated that the algorithm maintains the accuracy in the case of multiple defects compared to conventional algorithms based on Born approximation.

  2. Estimation of an accuracy index of a diagnostic biomarker when the reference biomarker is continuous and measured with error.

    PubMed

    Wu, Mixia; Zhang, Dianchen; Liu, Aiyi

    2016-01-01

    New biomarkers continue to be developed for the purpose of diagnosis, and their diagnostic performances are typically compared with an existing reference biomarker used for the same purpose. Considerable amounts of research have focused on receiver operating characteristic curves analysis when the reference biomarker is dichotomous. In the situation where the reference biomarker is measured on a continuous scale and dichotomization is not practically appealing, an index was proposed in the literature to measure the accuracy of a continuous biomarker, which is essentially a linear function of the popular Kendall's tau. We consider the issue of estimating such an accuracy index when the continuous reference biomarker is measured with errors. We first investigate the impact of measurement errors on the accuracy index, and then propose methods to correct for the bias due to measurement errors. Simulation results show the effectiveness of the proposed estimator in reducing biases. The methods are exemplified with hemoglobin A1c measurements obtained from both the central lab and a local lab to evaluate the accuracy of the mean data obtained from the metered blood glucose monitoring against the centrally measured hemoglobin A1c from a behavioral intervention study for families of youth with type 1 diabetes.

  3. Prediction of soil properties using imaging spectroscopy: Considering fractional vegetation cover to improve accuracy

    NASA Astrophysics Data System (ADS)

    Franceschini, M. H. D.; Demattê, J. A. M.; da Silva Terra, F.; Vicente, L. E.; Bartholomeus, H.; de Souza Filho, C. R.

    2015-06-01

    Spectroscopic techniques have become attractive to assess soil properties because they are fast, require little labor and may reduce the amount of laboratory waste produced when compared to conventional methods. Imaging spectroscopy (IS) can have further advantages compared to laboratory or field proximal spectroscopic approaches such as providing spatially continuous information with a high density. However, the accuracy of IS derived predictions decreases when the spectral mixture of soil with other targets occurs. This paper evaluates the use of spectral data obtained by an airborne hyperspectral sensor (ProSpecTIR-VS - Aisa dual sensor) for prediction of physical and chemical properties of Brazilian highly weathered soils (i.e., Oxisols). A methodology to assess the soil spectral mixture is adapted and a progressive spectral dataset selection procedure, based on bare soil fractional cover, is proposed and tested. Satisfactory performances are obtained specially for the quantification of clay, sand and CEC using airborne sensor data (R2 of 0.77, 0.79 and 0.54; RPD of 2.14, 2.22 and 1.50, respectively), after spectral data selection is performed; although results obtained for laboratory data are more accurate (R2 of 0.92, 0.85 and 0.75; RPD of 3.52, 2.62 and 2.04, for clay, sand and CEC, respectively). Most importantly, predictions based on airborne-derived spectra for which the bare soil fractional cover is not taken into account show considerable lower accuracy, for example for clay, sand and CEC (RPD of 1.52, 1.64 and 1.16, respectively). Therefore, hyperspectral remotely sensed data can be used to predict topsoil properties of highly weathered soils, although spectral mixture of bare soil with vegetation must be considered in order to achieve an improved prediction accuracy.

  4. Interval Timing Accuracy and Scalar Timing in C57BL/6 Mice

    PubMed Central

    Buhusi, Catalin V.; Aziz, Dyana; Winslow, David; Carter, Rickey E.; Swearingen, Joshua E.; Buhusi, Mona C.

    2010-01-01

    In many species, interval timing behavior is accurate—appropriate estimated durations—and scalar—errors vary linearly with estimated durations. While accuracy has been previously examined, scalar timing has not been yet clearly demonstrated in house mice (Mus musculus), raising concerns about mouse models of human disease. We estimated timing accuracy and precision in C57BL/6 mice, the most used background strain for genetic models of human disease, in a peak-interval procedure with multiple intervals. Both when timing two intervals (Experiment 1) or three intervals (Experiment 2), C57BL/6 mice demonstrated varying degrees of timing accuracy. Importantly, both at individual and group level, their precision varied linearly with the subjective estimated duration. Further evidence for scalar timing was obtained using an intraclass correlation statistic. This is the first report of consistent, reliable scalar timing in a sizable sample of house mice, thus validating the PI procedure as a valuable technique, the intraclass correlation statistic as a powerful test of the scalar property, and the C57BL/6 strain as a suitable background for behavioral investigations of genetically engineered mice modeling disorders of interval timing. PMID:19824777

  5. Statistical evaluation of accelerated stability data obtained at a single temperature. I. Effect of experimental errors in evaluation of stability data obtained.

    PubMed

    Yoshioka, S; Aso, Y; Takeda, Y

    1990-06-01

    Accelerated stability data obtained at a single temperature is statistically evaluated, and the utility of such data for assessment of stability is discussed focussing on the chemical stability of solution-state dosage forms. The probability that the drug content of a product is observed to be within the lower specification limit in the accelerated test is interpreted graphically. This probability depends on experimental errors in the assay and temperature control, as well as the true degradation rate and activation energy. Therefore, the observation that the drug content meets the specification in the accelerated testing can provide only limited information on the shelf-life of the drug, without the knowledge of the activation energy and the accuracy and precision of the assay and temperature control.

  6. Impact of new clock technologies on the stability and accuracy of the International Atomic Time TAI.

    NASA Astrophysics Data System (ADS)

    Thomas, C.

    1997-05-01

    The BIPM Time Section is in charge of the generation of the reference time scales TAI and UTC. Both time scales are obtained in deferred-time by combining the data front a number of atomic clocks spread worldwide. The accuracy of TAI is estimated by the departure between the duration of the TAI scale interval and the SI second as produced on the rotating geoid by primary frequency standards. It is now possible to estimate TAI accuracy through the combination of results obtained from six different primary standards: LPTF-FO1, PTB CS1, PTB CS2, PTB CS3, NIST-7, and SU MCsR 102, all corrected for the black-body radiation shift. This led to a mean departure of the TAI scale interval of +2.0×10-14s over 1995, known with a relative uncertainty of 0.5×10-14(1σ).

  7. Effect of provider volume on the accuracy of hospital report cards: a Monte Carlo study.

    PubMed

    Austin, Peter C; Reeves, Mathew J

    2014-03-01

    Hospital report cards, in which outcomes after the provision of medical or surgical care are compared across healthcare providers, are being published with increasing frequency. However, the accuracy of such comparisons is controversial, especially when case volumes are small. The objective was to determine the relationship between hospital case volume and the accuracy of hospital report cards. Monte Carlo simulations were used to examine the influence of hospital case volume on the accuracy of hospital report cards in a setting in which true hospital performance was known with certainty, and perfect risk-adjustment was feasible. The parameters used to generate the simulated data sets were obtained from empirical analyses of data on patients hospitalized with acute myocardial infarction in Ontario, Canada, in which the overall 30-day mortality rate was 11.1%. We found that provider volume had a strong effect on the accuracy of hospital report cards. However, provider volume had to be >300 before ≥70% of hospitals were correctly classified. Furthermore, hospital volume had to be >1000 before ≥80% of hospitals were correctly classified. Producers and users of hospital report cards need to be aware that, even when perfect risk adjustment is possible, the accuracy of hospital report cards is, at best, modest for small to medium-sized case loads (i.e., 100-300). Hospital report cards displayed high degrees of accuracy only when provider volumes exceeded the typical annual hospital case load for many cardiovascular conditions and procedures.

  8. Explicit area-based accuracy assessment for mangrove tree crown delineation using Geographic Object-Based Image Analysis (GEOBIA)

    NASA Astrophysics Data System (ADS)

    Kamal, Muhammad; Johansen, Kasper

    2017-10-01

    Effective mangrove management requires spatially explicit information of mangrove tree crown map as a basis for ecosystem diversity study and health assessment. Accuracy assessment is an integral part of any mapping activities to measure the effectiveness of the classification approach. In geographic object-based image analysis (GEOBIA) the assessment of the geometric accuracy (shape, symmetry and location) of the created image objects from image segmentation is required. In this study we used an explicit area-based accuracy assessment to measure the degree of similarity between the results of the classification and reference data from different aspects, including overall quality (OQ), user's accuracy (UA), producer's accuracy (PA) and overall accuracy (OA). We developed a rule set to delineate the mangrove tree crown using WorldView-2 pan-sharpened image. The reference map was obtained by visual delineation of the mangrove tree crowns boundaries form a very high-spatial resolution aerial photograph (7.5cm pixel size). Ten random points with a 10 m radius circular buffer were created to calculate the area-based accuracy assessment. The resulting circular polygons were used to clip both the classified image objects and reference map for area comparisons. In this case, the area-based accuracy assessment resulted 64% and 68% for the OQ and OA, respectively. The overall quality of the calculation results shows the class-related area accuracy; which is the area of correctly classified as tree crowns was 64% out of the total area of tree crowns. On the other hand, the overall accuracy of 68% was calculated as the percentage of all correctly classified classes (tree crowns and canopy gaps) in comparison to the total class area (an entire image). Overall, the area-based accuracy assessment was simple to implement and easy to interpret. It also shows explicitly the omission and commission error variations of object boundary delineation with colour coded polygons.

  9. Accuracy of Self-reported Height and Weight in a Community-Based Sample of Older African Americans and Whites

    PubMed Central

    Kuchibhatla, Maragatha N.; Whitson, Heather E.; Batch, Bryan C.; Svetkey, Laura P.; Pieper, Carl F.; Kraus, William E.; Cohen, Harvey J.; Blazer, Dan G.

    2010-01-01

    Background. To ascertain accuracy of self-reported height, weight (and hence body mass index) in African American and white women and men older than 70 years of age. Method. The sample consisted of cognitively intact participants at the third in-person wave (1992–1993) of the Duke Established Populations for Epidemiologic Studies of the Elderly (age 71 and older, N = 1761; residents of five adjacent counties, one urban, four rural). During in-person, in-home interviews using trained interviewers, height and weight were self-reported (and measured later in the same visit using a standardized protocol), and information were obtained on race, sex, and age. Results. Accuracy of self-reported height and weight was high (intraclass correlation coefficient 0.85 and 0.97, respectively) but differed as a function of race and age. On average, all groups overestimated their height; whereas (non-Hispanic) white men and women underestimated their weight, African Americans overestimated their weight. Overestimation of height and weight was more marked in persons 85 years and older. Specificity for overweight (body mass index [kg/m2] ≥ 25) and obesity (body mass index ≥ 30) ranged from 0.90 to 0.99 for African Americans and whites, but sensitivity was better for African Americans (overweight: 0.81, obesity: 0.89), than for whites (0.66 and 0.57, respectively). Conclusions. Height and weight self-reported by African Americans and whites over the age of 70 can be used in epidemiological studies, with greater caution needed for self-reports of whites, and of persons 85 years of age or older. PMID:20530243

  10. Video image analysis in the Australian meat industry - precision and accuracy of predicting lean meat yield in lamb carcasses.

    PubMed

    Hopkins, D L; Safari, E; Thompson, J M; Smith, C R

    2004-06-01

    A wide selection of lamb types of mixed sex (ewes and wethers) were slaughtered at a commercial abattoir and during this process images of 360 carcasses were obtained online using the VIAScan® system developed by Meat and Livestock Australia. Soft tissue depth at the GR site (thickness of tissue over the 12th rib 110 mm from the midline) was measured by an abattoir employee using the AUS-MEAT sheep probe (PGR). Another measure of this thickness was taken in the chiller using a GR knife (NGR). Each carcass was subsequently broken down to a range of trimmed boneless retail cuts and the lean meat yield determined. The current industry model for predicting meat yield uses hot carcass weight (HCW) and tissue depth at the GR site. A low level of accuracy and precision was found when HCW and PGR were used to predict lean meat yield (R(2)=0.19, r.s.d.=2.80%), which could be improved markedly when PGR was replaced by NGR (R(2)=0.41, r.s.d.=2.39%). If the GR measures were replaced by 8 VIAScan® measures then greater prediction accuracy could be achieved (R(2)=0.52, r.s.d.=2.17%). A similar result was achieved when the model was based on principal components (PCs) computed from the 8 VIAScan® measures (R(2)=0.52, r.s.d.=2.17%). The use of PCs also improved the stability of the model compared to a regression model based on HCW and NGR. The transportability of the models was tested by randomly dividing the data set and comparing coefficients and the level of accuracy and precision. Those models based on PCs were superior to those based on regression. It is demonstrated that with the appropriate modeling the VIAScan® system offers a workable method for predicting lean meat yield automatically.

  11. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques.

    PubMed

    Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed

    2017-01-01

    Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.

  12. Localization accuracy of sphere fiducials in computed tomography images

    NASA Astrophysics Data System (ADS)

    Kobler, Jan-Philipp; Díaz Díaz, Jesus; Fitzpatrick, J. Michael; Lexow, G. Jakob; Majdani, Omid; Ortmaier, Tobias

    2014-03-01

    In recent years, bone-attached robots and microstereotactic frames have attracted increasing interest due to the promising targeting accuracy they provide. Such devices attach to a patient's skull via bone anchors, which are used as landmarks during intervention planning as well. However, as simulation results reveal, the performance of such mechanisms is limited by errors occurring during the localization of their bone anchors in preoperatively acquired computed tomography images. Therefore, it is desirable to identify the most suitable fiducials as well as the most accurate method for fiducial localization. We present experimental results of a study focusing on the fiducial localization error (FLE) of spheres. Two phantoms equipped with fiducials made from ferromagnetic steel and titanium, respectively, are used to compare two clinically available imaging modalities (multi-slice CT (MSCT) and cone-beam CT (CBCT)), three localization algorithms as well as two methods for approximating the FLE. Furthermore, the impact of cubic interpolation applied to the images is investigated. Results reveal that, generally, the achievable localization accuracy in CBCT image data is significantly higher compared to MSCT imaging. The lowest FLEs (approx. 40 μm) are obtained using spheres made from titanium, CBCT imaging, template matching based on cross correlation for localization, and interpolating the images by a factor of sixteen. Nevertheless, the achievable localization accuracy of spheres made from steel is only slightly inferior. The outcomes of the presented study will be valuable considering the optimization of future microstereotactic frame prototypes as well as the operative workflow.

  13. Measuring the Accuracy of Simple Evolving Connectionist System with Varying Distance Formulas

    NASA Astrophysics Data System (ADS)

    Al-Khowarizmi; Sitompul, O. S.; Suherman; Nababan, E. B.

    2017-12-01

    Simple Evolving Connectionist System (SECoS) is a minimal implementation of Evolving Connectionist Systems (ECoS) in artificial neural networks. The three-layer network architecture of the SECoS could be built based on the given input. In this study, the activation value for the SECoS learning process, which is commonly calculated using normalized Hamming distance, is also calculated using normalized Manhattan distance and normalized Euclidean distance in order to compare the smallest error value and best learning rate obtained. The accuracy of measurement resulted by the three distance formulas are calculated using mean absolute percentage error. In the training phase with several parameters, such as sensitivity threshold, error threshold, first learning rate, and second learning rate, it was found that normalized Euclidean distance is more accurate than both normalized Hamming distance and normalized Manhattan distance. In the case of beta fibrinogen gene -455 G/A polymorphism patients used as training data, the highest mean absolute percentage error value is obtained with normalized Manhattan distance compared to normalized Euclidean distance and normalized Hamming distance. However, the differences are very small that it can be concluded that the three distance formulas used in SECoS do not have a significant effect on the accuracy of the training results.

  14. Comparison of the Diagnostic Accuracy of DSC- and Dynamic Contrast-Enhanced MRI in the Preoperative Grading of Astrocytomas.

    PubMed

    Nguyen, T B; Cron, G O; Perdrizet, K; Bezzina, K; Torres, C H; Chakraborty, S; Woulfe, J; Jansen, G H; Sinclair, J; Thornhill, R E; Foottit, C; Zanette, B; Cameron, I G

    2015-11-01

    Dynamic contrast-enhanced MR imaging parameters can be biased by poor measurement of the vascular input function. We have compared the diagnostic accuracy of dynamic contrast-enhanced MR imaging by using a phase-derived vascular input function and "bookend" T1 measurements with DSC MR imaging for preoperative grading of astrocytomas. This prospective study included 48 patients with a new pathologic diagnosis of an astrocytoma. Preoperative MR imaging was performed at 3T, which included 2 injections of 5-mL gadobutrol for dynamic contrast-enhanced and DSC MR imaging. During dynamic contrast-enhanced MR imaging, both magnitude and phase images were acquired to estimate plasma volume obtained from phase-derived vascular input function (Vp_Φ) and volume transfer constant obtained from phase-derived vascular input function (K(trans)_Φ) as well as plasma volume obtained from magnitude-derived vascular input function (Vp_SI) and volume transfer constant obtained from magnitude-derived vascular input function (K(trans)_SI). From DSC MR imaging, corrected relative CBV was computed. Four ROIs were placed over the solid part of the tumor, and the highest value among the ROIs was recorded. A Mann-Whitney U test was used to test for difference between grades. Diagnostic accuracy was assessed by using receiver operating characteristic analysis. Vp_ Φ and K(trans)_Φ values were lower for grade II compared with grade III astrocytomas (P < .05). Vp_SI and K(trans)_SI were not significantly different between grade II and grade III astrocytomas (P = .08-0.15). Relative CBV and dynamic contrast-enhanced MR imaging parameters except for K(trans)_SI were lower for grade III compared with grade IV (P ≤ .05). In differentiating low- and high-grade astrocytomas, we found no statistically significant difference in diagnostic accuracy between relative CBV and dynamic contrast-enhanced MR imaging parameters. In the preoperative grading of astrocytomas, the diagnostic accuracy of dynamic

  15. Effect of Kinesiotape Applications on Ball Velocity and Accuracy in Amateur Soccer and Handball

    PubMed Central

    Müller, Carsten; Brandes, Mirko

    2015-01-01

    Evidence supporting performance enhancing effects of kinesiotape in sports is missing. The aims of this study were to evaluate effects of kinesiotape applications with regard to shooting and throwing performance in 26 amateur soccer and 32 handball players, and to further investigate if these effects were influenced by the players’ level of performance. Ball speed as the primary outcome and accuracy of soccer kicks and handball throws were analyzed with and without kinesiotape by means of radar units and video recordings. The application of kinesiotapes significantly increased ball speed in soccer by 1.4 km/h (p=0.047) and accuracy with a lesser distance from the target by −6.9 cm (p=0.039). Ball velocity in handball throws also significantly increased by 1.2 km/h (p=0.013), while accuracy was deteriorated with a greater distance from the target by 3.4 cm (p=0.005). Larger effects with respect to ball speed were found in players with a lower performance level in kicking (1.7 km/h, p=0.028) and throwing (1.8 km/h, p=0.001) compared with higher level soccer and handball players (1.2 km/h, p=0.346 and 0.5 km/h, p=0.511, respectively). In conclusion, the applications of kinesiotape used in this study might have beneficial effects on performance in amateur soccer, but the gain in ball speed in handball is counteracted by a significant deterioration of accuracy. Subgroup analyses indicate that kinesiotape may yield larger effects on ball velocity in athletes with lower kicking and throwing skills. PMID:26839612

  16. The Assessment of Quality, Accuracy, and Readability of Online Educational Resources for Platelet-Rich Plasma.

    PubMed

    Ghodasra, Jason H; Wang, Dean; Jayakar, Rohit G; Jensen, Andrew R; Yamaguchi, Kent T; Hegde, Vishal V; Jones, Kristofer J

    2018-01-01

    To critically evaluate the quality, accuracy, and readability of readily available Internet patient resources for platelet-rich plasma (PRP) as a treatment modality for musculoskeletal injuries. Using the 3 most commonly used Internet search engines (Google, Bing, Yahoo), the search term "platelet rich plasma" was entered, and the first 50 websites from each search were reviewed. The website's affiliation was identified. Quality was evaluated using 25-point criteria based on guidelines published by the American Academy of Orthopaedic Surgeons, and accuracy was assessed with a previously described 12-point grading system by 3 reviewers independently. Readability was evaluated using the Flesch-Kincaid (FK) grade score. A total of 46 unique websites were identified and evaluated. The average quality and accuracy was 9.4 ± 3.4 (maximum 25) and 7.9 ± 2.3 (maximum 12), respectively. The average FK grade level was 12.6 ± 2.4, which is several grades higher than the recommended eighth-grade level for patient education material. Ninety-one percent (42/46) of websites were authored by physicians, and 9% (4/46) contained commercial bias. Mean quality was significantly greater in websites authored by health care providers (9.8 ± 3.1 vs 5.9 ± 4.7, P = .029) and in websites without commercial bias (9.9 ± 3.1 vs 4.5 ± 3.2, P = .002). Mean accuracy was significantly lower in websites authored by health care providers (7.6 ± 2.2 vs 11.0 ± 1.2, P = .004). Only 24% (11/46) reported that PRP remains an investigational treatment. The accuracy and quality of online patient resources for PRP are poor, and the information overestimates the reading ability of the general population. Websites authored by health care providers had higher quality but lower accuracy. Additionally, the majority of websites do not identify PRP as an experimental treatment, which may fail to provide appropriate patient understanding and expectations. Physicians should educate patients that many online

  17. Assessing and Ensuring GOES-R Magnetometer Accuracy

    NASA Technical Reports Server (NTRS)

    Carter, Delano R.; Todirita, Monica; Kronenwetter, Jeffrey; Chu, Donald

    2016-01-01

    The GOES-R magnetometer subsystem accuracy requirement is 1.7 nanoteslas (nT). During quiet times (100 nT), accuracy is defined as absolute mean plus 3 sigma. During storms (300 nT), accuracy is defined as absolute mean plus 2 sigma. Error comes both from outside the magnetometers, e.g. spacecraft fields and misalignments, as well as inside, e.g. zero offset and scale factor errors. Because zero offset and scale factor drift over time, it will be necessary to perform annual calibration maneuvers. To predict performance before launch, we have used Monte Carlo simulations and covariance analysis. Both behave as expected, and their accuracy predictions agree within 30%. With the proposed calibration regimen, both suggest that the GOES-R magnetometer subsystem will meet its accuracy requirements.

  18. Cooled radiofrequency ablation for bilateral greater occipital neuralgia.

    PubMed

    Vu, Tiffany; Chhatre, Akhil

    2014-01-01

    This report describes a case of bilateral greater occipital neuralgia treated with cooled radiofrequency ablation. The case is considered in relation to a review of greater occipital neuralgia, continuous thermal and pulsed radiofrequency ablation, and current medical literature on cooled radiofrequency ablation. In this case, a 35-year-old female with a 2.5-year history of chronic suboccipital bilateral headaches, described as constant, burning, and pulsating pain that started at the suboccipital region and radiated into her vertex. She was diagnosed with bilateral greater occipital neuralgia. She underwent cooled radiofrequency ablation of bilateral greater occipital nerves with minimal side effects and 75% pain reduction. Cooled radiofrequency ablation of the greater occipital nerve in challenging cases is an alternative to pulsed and continuous RFA to alleviate pain with less side effects and potential for long-term efficacy.

  19. Cooled Radiofrequency Ablation for Bilateral Greater Occipital Neuralgia

    PubMed Central

    Chhatre, Akhil

    2014-01-01

    This report describes a case of bilateral greater occipital neuralgia treated with cooled radiofrequency ablation. The case is considered in relation to a review of greater occipital neuralgia, continuous thermal and pulsed radiofrequency ablation, and current medical literature on cooled radiofrequency ablation. In this case, a 35-year-old female with a 2.5-year history of chronic suboccipital bilateral headaches, described as constant, burning, and pulsating pain that started at the suboccipital region and radiated into her vertex. She was diagnosed with bilateral greater occipital neuralgia. She underwent cooled radiofrequency ablation of bilateral greater occipital nerves with minimal side effects and 75% pain reduction. Cooled radiofrequency ablation of the greater occipital nerve in challenging cases is an alternative to pulsed and continuous RFA to alleviate pain with less side effects and potential for long-term efficacy. PMID:24716017

  20. Cadastral Database Positional Accuracy Improvement

    NASA Astrophysics Data System (ADS)

    Hashim, N. M.; Omar, A. H.; Ramli, S. N. M.; Omar, K. M.; Din, N.

    2017-10-01

    Positional Accuracy Improvement (PAI) is the refining process of the geometry feature in a geospatial dataset to improve its actual position. This actual position relates to the absolute position in specific coordinate system and the relation to the neighborhood features. With the growth of spatial based technology especially Geographical Information System (GIS) and Global Navigation Satellite System (GNSS), the PAI campaign is inevitable especially to the legacy cadastral database. Integration of legacy dataset and higher accuracy dataset like GNSS observation is a potential solution for improving the legacy dataset. However, by merely integrating both datasets will lead to a distortion of the relative geometry. The improved dataset should be further treated to minimize inherent errors and fitting to the new accurate dataset. The main focus of this study is to describe a method of angular based Least Square Adjustment (LSA) for PAI process of legacy dataset. The existing high accuracy dataset known as National Digital Cadastral Database (NDCDB) is then used as bench mark to validate the results. It was found that the propose technique is highly possible for positional accuracy improvement of legacy spatial datasets.

  1. Evaluation of spatial filtering on the accuracy of wheat area estimate

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N. (Principal Investigator); Moreira, M. A.; Chen, S. C.; Delima, A. M.

    1982-01-01

    A 3 x 3 pixel spatial filter for postclassification was used for wheat classification to evaluate the effects of this procedure on the accuracy of area estimation using LANDSAT digital data obtained from a single pass. Quantitative analyses were carried out in five test sites (approx 40 sq km each) and t tests showed that filtering with threshold values significantly decreased errors of commission and omission. In area estimation filtering improved the overestimate of 4.5% to 2.7% and the root-mean-square error decreased from 126.18 ha to 107.02 ha. Extrapolating the same procedure of automatic classification using spatial filtering for postclassification to the whole study area, the accuracy in area estimate was improved from the overestimate of 10.9% to 9.7%. It is concluded that when single pass LANDSAT data is used for crop identification and area estimation the postclassification procedure using a spatial filter provides a more accurate area estimate by reducing classification errors.

  2. Giant Spontaneous Greater Saphenous Vein Aneurysm.

    PubMed

    Lim, Sungho; Halandras, Pegge; Hershberger, Richard; Aulivola, Bernadette; Crisostomo, Paul

    2017-07-01

    Venous aneurysm, a rare venous anomaly, poses increased risk of distal thromboembolic event. Superficial venous aneurysm, such as greater saphenous vein aneurysm, is an uncommon subset with nonspecific symptoms and often a delay in diagnosis. Symptomatic patients or patients with a thromboembolic event may benefit from surgical intervention with low morbidity. This case report describes an isolated spontaneous greater saphenous vein aneurysm which was successfully ligated and resected for symptomatic relief and prevention of distal thromboembolism. Published by Elsevier Inc.

  3. Designing informative warning signals: Effects of indicator type, modality, and task demand on recognition speed and accuracy

    PubMed Central

    Stevens, Catherine J.; Brennan, David; Petocz, Agnes; Howell, Clare

    2009-01-01

    An experiment investigated the assumption that natural indicators which exploit existing learned associations between a signal and an event make more effective warnings than previously unlearned symbolic indicators. Signal modality (visual, auditory) and task demand (low, high) were also manipulated. Warning effectiveness was indexed by accuracy and reaction time (RT) recorded during training and dual task test phases. Thirty-six participants were trained to recognize 4 natural and 4 symbolic indicators, either visual or auditory, paired with critical incidents from an aviation context. As hypothesized, accuracy was greater and RT was faster in response to natural indicators during the training phase. This pattern of responding was upheld in test phase conditions with respect to accuracy but observed in RT only in test phase conditions involving high demand and the auditory modality. Using the experiment as a specific example, we argue for the importance of considering the cognitive contribution of the user (viz., prior learned associations) in the warning design process. Drawing on semiotics and cognitive psychology, we highlight the indexical nature of so-called auditory icons or natural indicators and argue that the cogniser is an indispensable element in the tripartite nature of signification. PMID:20523852

  4. Improved Accuracy of Continuous Glucose Monitoring Systems in Pediatric Patients with Diabetes Mellitus: Results from Two Studies.

    PubMed

    Laffel, Lori

    2016-02-01

    This study was designed to evaluate accuracy, performance, and safety of the Dexcom (San Diego, CA) G4(®) Platinum continuous glucose monitoring (CGM) system (G4P) compared with the Dexcom G4 Platinum with Software 505 algorithm (SW505) when used as adjunctive management to blood glucose (BG) monitoring over a 7-day period in youth, 2-17 years of age, with diabetes. Youth wore either one or two sensors placed on the abdomen or upper buttocks for 7 days, calibrating the device twice daily with a uniform BG meter. Participants had one in-clinic session on Day 1, 4, or 7, during which fingerstick BG measurements (self-monitoring of blood glucose [SMBG]) were obtained every 30 ± 5 min for comparison with CGM, and in youth 6-17 years of age, reference YSI glucose measurements were obtained from arterialized venous blood collected every 15 ± 5 min for comparison with CGM. The sensor was removed by the participant/family after 7 days. In comparison of 2,922 temporally paired points of CGM with the reference YSI measurement for G4P and 2,262 paired points for SW505, the mean absolute relative difference (MARD) was 17% for G4P versus 10% for SW505 (P < 0.0001). In comparison of 16,318 temporally paired points of CGM with SMBG for G4P and 4,264 paired points for SW505, MARD was 15% for G4P versus 13% for SW505 (P < 0.0001). Similarly, error grid analyses indicated superior performance with SW505 compared with G4P in comparison of CGM with YSI and CGM with SMBG results, with greater percentages of SW505 results falling within error grid Zone A or the combined Zones A plus B. There were no serious adverse events or device-related serious adverse events for either the G4P or the SW505, and there was no sensor breakoff. The updated algorithm offers substantial improvements in accuracy and performance in pediatric patients with diabetes. Use of CGM with improved performance has potential to increase glucose time in range and improve glycemic outcomes for youth.

  5. Meta-accuracy and relationship quality: Weighing the costs and benefits of knowing what people really think about you.

    PubMed

    Carlson, Erika N

    2016-08-01

    People use metaperceptions, or their beliefs about how other people perceive them, to initiate and maintain social bonds. Are accurate metaperceptions associated with higher quality relationships? In four studies, the current research answers this question but considers the possibility that the self might not experience the same relational benefits of accurate metaperceptions, or meta-accuracy, as the people who form judgments about the self. For example, people tend to like individuals who have accurate self-perceptions, yet individuals tend to enjoy their own relationships more with people they believe see them in desirable ways. To test whether meta-accuracy is linked to relationship quality and whether this link differs for the self and others, meta-accuracy for personality traits as well as metaperceiver- and judge-reported relationship quality were assessed among new acquaintances (N = 184), peers (N = 228), friends (N = 273), and romantic partners (N = 401). Results suggested that judges enjoyed relationships more with metaperceivers who knew the impression they made, regardless of whether judges' impressions were desirable (i.e., positive or self-verifying). Initial meta-accuracy also predicted greater relationship quality over time, suggesting that accurate metaperceptions have positive effects on relationships. In contrast, rather than enjoying relationships more when they were accurate, metaperceivers enjoyed relationships more when they believed judges perceived them in positive or self-verifying ways. Thus, meta-accuracy seems to be a virtue in the eyes of judges, but metaperceivers do not seem to reap the same benefits of knowing what others really think. Implications for improving meta-accuracy are discussed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  6. Accuracy of maxillary positioning after standard and inverted orthognathic sequencing.

    PubMed

    Ritto, Fabio G; Ritto, Thiago G; Ribeiro, Danilo Passeado; Medeiros, Paulo José; de Moraes, Márcio

    2014-05-01

    This study aimed to compare the accuracy of maxillary positioning after bimaxillary orthognathic surgery, using 2 sequences. A total of 80 cephalograms (40 preoperative and 40 postoperative) from 40 patients were analyzed. Group 1 included radiographs of patients submitted to conventional sequence, whereas group 2 patients were submitted to inverted sequence. The final position of the maxillary central incisor was obtained after vertical and horizontal measurements of the tracings, and it was compared with what had been planned. The null hypothesis, which stated that there would be no difference between the groups, was tested. After applying the Welch t test for comparison of mean differences between maxillary desired and achieved position, considering a statistical significance of 5% and a 2-tailed test, the null hypothesis was not rejected (P > .05). Thus, there was no difference in the accuracy of maxillary positioning between groups. Conventional and inverted sequencing proved to be reliable in positioning the maxilla after LeFort I osteotomy in bimaxillary orthognathic surgeries. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Accuracy improvement in the TDR-based localization of water leaks

    NASA Astrophysics Data System (ADS)

    Cataldo, Andrea; De Benedetto, Egidio; Cannazza, Giuseppe; Monti, Giuseppina; Demitri, Christian

    A time domain reflectometry (TDR)-based system for the localization of water leaks has been recently developed by the authors. This system, which employs wire-like sensing elements to be installed along the underground pipes, has proven immune to the limitations that affect the traditional, acoustic leak-detection systems. Starting from the positive results obtained thus far, in this work, an improvement of this TDR-based system is proposed. More specifically, the possibility of employing a low-cost, water-absorbing sponge to be placed around the sensing element for enhancing the accuracy in the localization of the leak is addressed. To this purpose, laboratory experiments were carried out mimicking a water leakage condition, and two sensing elements (one embedded in a sponge and one without sponge) were comparatively used to identify the position of the leak through TDR measurements. Results showed that, thanks to the water retention capability of the sponge (which maintains the leaked water more localized), the sensing element embedded in the sponge leads to a higher accuracy in the evaluation of the position of the leak.

  8. Accuracy vs. Fluency: Which Comes First in ESL Instruction?

    ERIC Educational Resources Information Center

    Ebsworth, Miriam Eisenstein

    1998-01-01

    Discusses the debate over fluency versus accuracy in teaching English-as-a-Second-Language (ESL). Defines fluency and accuracy; examines alternative approaches (meaning first, accuracy first, and accuracy and fluency from the beginning); evaluates the alternatives; and highlights implications for teaching ESL. A sidebar presents an accuracy and…

  9. Accuracy Of LTPP Traffic Loading Estimates

    DOT National Transportation Integrated Search

    1998-07-01

    The accuracy and reliability of traffic load estimates are key to determining a pavement's life expectancy. To better understand the variability of traffic loading rates and its effect on the accuracy of the Long Term Pavement Performance (LTPP) prog...

  10. Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear

    PubMed Central

    Stilling, M.; Kold, S.; de Raedt, S.; Andersen, N. T.; Rahbek, O.; Søballe, K.

    2012-01-01

    Objectives The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear. Methods A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed. Results The precision for 2D wear measures was 0.078 mm, 0.102 mm, and 0.076 mm for EGS-RSA, MB-RSA, and PolyWare, respectively. For the 3D wear measures the precision was 0.185 mm, 0.189 mm, and 0.244 mm for EGS-RSA, MB-RSA, and PolyWare respectively. Repeatability was similar for all methods within the same dimension, when compared between 2D and 3D (all p > 0.28). For the 2D RSA methods, accuracy was below 0.055 mm and at least 0.335 mm for PolyWare. For 3D measurements, accuracy was 0.1 mm, 0.2 mm, and 0.3 mm for EGS-RSA, MB-RSA and PolyWare respectively. PolyWare was less accurate compared with RSA methods (p = 0.036). No difference was observed between the RSA methods (p = 0.10). Conclusions For all methods, precision and accuracy were better in 2D, with RSA methods being superior in accuracy. Although less accurate and precise, 3D RSA defines the clinically relevant wear pattern (multidirectional). PolyWare is a good and low-cost alternative to RSA, despite being less accurate and requiring a larger sample size. PMID:23610688

  11. Greater Working Memory Load Results in Greater Medial Temporal Activity at Retrieval

    PubMed Central

    Quiroz, Yakeel T.; Hasselmo, Michael E.; Stern, Chantal E.

    2009-01-01

    Most functional magnetic resonance imaging (fMRI) studies examining working memory (WM) load have focused on the prefrontal cortex (PFC) and have demonstrated increased prefrontal activity with increased load. Here we examined WM load effects in the medial temporal lobe (MTL) using an fMRI Sternberg task with novel complex visual scenes. Trials consisted of 3 sequential events: 1) sample presentation (encoding), 2) delay period (maintenance), and 3) probe period (retrieval). During sample encoding, subjects saw either 2 or 4 pictures consecutively. During retrieval, subjects indicated whether the probe picture matched one of the sample pictures. Results revealed that activity in the left anterior hippocampal formation, bilateral retrosplenial area, and left amygdala was greater at retrieval for trials with larger memory load, whereas activity in the PFC was greater at encoding for trials with larger memory load. There was no load effect during the delay. When encoding, maintenance, and retrieval periods were compared with fixation, activity was present in the hippocampal body/tail and fusiform gyrus bilaterally during encoding and retrieval, but not maintenance. Bilateral dorsolateral prefrontal activity was present during maintenance, but not during encoding or retrieval. The results support models of WM predicting that activity in the MTL should be modulated by WM load. PMID:19224975

  12. Guidance on Compatibility of UST Systems with Ethanol Blends Greater Than 10 Percent and Biodiesel Blends Greater Than 20 Percent

    EPA Pesticide Factsheets

    EPA guidance on complying with the federal compatibility requirement for underground storage tank (UST) systems storing gasoline containing greater than 10 percent ethanol or diesel containing greater than 20 percent biodiesel.

  13. Isotopic composition of cosmic ray nuclei with Z greater than or equal to 10

    NASA Technical Reports Server (NTRS)

    Webber, W. R.; Lezniak, J. A.; Kish, J.

    1974-01-01

    Results of measurements of the isotopic composition of Z greater than or equal to 10 cosmic ray nuclei using a new technique employing a combination of Cerenkov and total energy counters. An effective mass resolution of about 0.4 AMU is obtained for particles with energies between 400 and 500 MeV/nuc and charges between 12 and 16. The preliminary mass distribution of nuclei with charges from 12 to 28 is presented and discussed.

  14. Evaluation of Automatic Vehicle Location accuracy

    DOT National Transportation Integrated Search

    1999-01-01

    This study assesses the accuracy of the Automatic Vehicle Location (AVL) data provided for the buses of the Ann Arbor Transportation Authority with Global Positioning System (GPS) technology. In a sample of eighty-nine bus trips two kinds of accuracy...

  15. Communication Accuracy in Magazine Science Reporting.

    ERIC Educational Resources Information Center

    Borman, Susan Cray

    1978-01-01

    Evaluators with scientific expertise who analyzed the accuracy of popularized science news in mass circulation magazines found that the over-all accuracy of the magazine articles was good, and that the major problem was the omission of relevant information. (GW)

  16. Accuracy of impressions with different impression materials in angulated implants.

    PubMed

    Reddy, S; Prasad, K; Vakil, H; Jain, A; Chowdhary, R

    2013-01-01

    To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were placed parallel to each other and perpendicular to the plane of the cast. In the second and third group (control), all three implants were placed at 10° and 15 o angulation respectively to the long axis of the cast, tilting towards the centre. Impressions were made with polyvinyl siloxane and polyether impression materials in a special tray, using a open tray impression technique from the master casts. These impressions were poured to obtain test casts. Three reference distances were evaluated on each test cast by using a profile projector and compared with control groups to determine the effect of combined interaction of implant angulation and impression materials on the accuracy of implant resultant cast. Statistical analysis revealed no significant difference in dimensional accuracy of the resultant casts made from two different impression materials (polyvinyl siloxane and polyether) by closed tray impression technique in parallel and angulated implants. On the basis of the results of this study, the use of both the impression materials i.e., polyether and polyvinyl siloxane impression is recommended for impression making in parallel as well as angulated implants.

  17. Accuracy comparison of guided surgery for dental implants according to the tissue of support: a systematic review and meta-analysis.

    PubMed

    Raico Gallardo, Yolanda Natali; da Silva-Olivio, Isabela Rodrigues Teixeira; Mukai, Eduardo; Morimoto, Susana; Sesma, Newton; Cordaro, Luca

    2017-05-01

    To systematically assess the current dental literature comparing the accuracy of computer-aided implant surgery when using different supporting tissues (tooth, mucosa, or bone). Two reviewers searched PubMed (1972 to January 2015) and the Cochrane Central Register of Controlled Trials (Central) (2002 to January 2015). For the assessment of accuracy, studies were included with the following outcome measures: (i) angle deviation, (ii) deviation at the entry point, and (iii) deviation at the apex. Eight clinical studies from the 1602 articles initially identified met the inclusion criteria for the qualitative analysis. Four studies (n = 599 implants) were evaluated using meta-analysis. The bone-supported guides showed a statistically significant greater deviation in angle (P < 0.001), entry point (P = 0.01), and the apex (P = 0.001) when compared to the tooth-supported guides. Conversely, when only retrospective studies were analyzed, not significant differences are revealed in the deviation of the entry point and apex. The mucosa-supported guides indicated a statistically significant greater reduction in angle deviation (P = 0.02), deviation at the entry point (P = 0.002), and deviation at the apex (P = 0.04) when compared to the bone-supported guides. Between the mucosa- and tooth-supported guides, there were no statistically significant differences for any of the outcome measures. It can be concluded that the tissue of the guide support influences the accuracy of computer-aided implant surgery. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Dr Google: The readability and accuracy of patient education websites for Graves' disease treatment.

    PubMed

    Purdy, Amanda C; Idriss, Almoatazbellah; Ahern, Susan; Lin, Elizabeth; Elfenbein, Dawn M

    2017-11-01

    National guidelines emphasize the importance of incorporating patient preferences into the recommendations for the treatment of Graves' disease. Many patients use the Internet to obtain health information, and search results can affect their treatment decisions. This study compares the readability and accuracy of patient-oriented online resources for the treatment of Graves' disease by website affiliation and treatment modality. A systematic Internet search was used to identify the top websites discussing the treatment of Graves' disease. Readability was measured using 5 standardized tests. Accuracy was assessed by a blinded, expert panel, which scored the accuracy of sites on a scale of 1 to 5. Mean readability and accuracy scores were compared among website affiliations and treatment modalities. We identified 13 unique websites, including 2 academic, 2 government, 5 nonprofit, and 4 private sites. There was a difference in both readability (mean 13.2, range 9.1-15.7, P = .003) and accuracy (mean 4.04, range 2.75-4.50, P = .019) based on website affiliation. Government sites (mean readability 11.1) were easier to read than academic (14.3, P < .01), nonprofit (13.9, P < .01), and private sites (13.5, P < .05). Academic sites (mean accuracy 4.50) were more accurate than private sites (3.56, P < .05). Online patient resources for the treatment of Graves' disease are written at an inappropriately high reading level. Academic sites contain both the most accurate and the most difficult to read information. Private sites represented the majority of our top results but contained the least accurate information. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, N., E-mail: nwen1@hfhs.org; Snyder, K. C.; Qin, Y.

    2016-05-15

    Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2more » mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.« less

  20. Accuracy of magnetic resonance based susceptibility measurements

    NASA Astrophysics Data System (ADS)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  1. Assessment of energy crops alternative to maize for biogas production in the Greater Region.

    PubMed

    Mayer, Frédéric; Gerin, Patrick A; Noo, Anaïs; Lemaigre, Sébastien; Stilmant, Didier; Schmit, Thomas; Leclech, Nathael; Ruelle, Luc; Gennen, Jerome; von Francken-Welz, Herbert; Foucart, Guy; Flammang, Jos; Weyland, Marc; Delfosse, Philippe

    2014-08-01

    The biomethane yield of various energy crops, selected among potential alternatives to maize in the Greater Region, was assessed. The biomass yield, the volatile solids (VS) content and the biochemical methane potential (BMP) were measured to calculate the biomethane yield per hectare of all plant species. For all species, the dry matter biomass yield and the VS content were the main factors that influence, respectively, the biomethane yield and the BMP. Both values were predicted with good accuracy by linear regressions using the biomass yield and the VS as independent variable. The perennial crop miscanthus appeared to be the most promising alternative to maize when harvested as green matter in autumn and ensiled. Miscanthus reached a biomethane yield of 5.5 ± 1 × 10(3)m(3)ha(-1) during the second year after the establishment, as compared to 5.3 ± 1 × 10(3)m(3)ha(-1) for maize under similar crop conditions. Copyright © 2014. Published by Elsevier Ltd.

  2. Determination of Classification Accuracy for Land Use/cover Types Using Landsat-Tm Spot-Mss and Multipolarized and Multi-Channel Synthetic Aperture Radar

    NASA Astrophysics Data System (ADS)

    Dondurur, Mehmet

    The primary objective of this study was to determine the degree to which modern SAR systems can be used to obtain information about the Earth's vegetative resources. Information obtainable from microwave synthetic aperture radar (SAR) data was compared with that obtainable from LANDSAT-TM and SPOT data. Three hypotheses were tested: (a) Classification of land cover/use from SAR data can be accomplished on a pixel-by-pixel basis with the same overall accuracy as from LANDSAT-TM and SPOT data. (b) Classification accuracy for individual land cover/use classes will differ between sensors. (c) Combining information derived from optical and SAR data into an integrated monitoring system will improve overall and individual land cover/use class accuracies. The study was conducted with three data sets for the Sleeping Bear Dunes test site in the northwestern part of Michigan's lower peninsula, including an October 1982 LANDSAT-TM scene, a June 1989 SPOT scene and C-, L- and P-Band radar data from the Jet Propulsion Laboratory AIRSAR. Reference data were derived from the Michigan Resource Information System (MIRIS) and available color infrared aerial photos. Classification and rectification of data sets were done using ERDAS Image Processing Programs. Classification algorithms included Maximum Likelihood, Mahalanobis Distance, Minimum Spectral Distance, ISODATA, Parallelepiped, and Sequential Cluster Analysis. Classified images were rectified as necessary so that all were at the same scale and oriented north-up. Results were analyzed with contingency tables and percent correctly classified (PCC) and Cohen's Kappa (CK) as accuracy indices using CSLANT and ImagePro programs developed for this study. Accuracy analyses were based upon a 1.4 by 6.5 km area with its long axis east-west. Reference data for this subscene total 55,770 15 by 15 m pixels with sixteen cover types, including seven level III forest classes, three level III urban classes, two level II range classes, two

  3. Accuracy of magnetic resonance imaging stereotactic coordinates with the cosman-roberts-wells frame.

    PubMed

    Carter, D A; Parsai, E I; Ayyangar, K M

    1999-01-01

    Quality assessment on the accuracy of a Cosman-Roberts-Wells (CRW) magnetic resonance imaging (MRI) stereotactic ring which had nonferrous stainless steel screws and positioning posts and a localizer with petroleum jelly in the fiducials, purchased in 1994, revealed errors of greater than 4 mm with targets in phantoms. Image fusion of objects within the phantom indicated the central area was accurately depicted by CT or MRI. We then tested a newer CRW- MRI ring (MRIA-IHR with titanium screws and posts) and localizer (MRIA-2-LF with fiducials filled with copper sulfate) and found that the MRI stereotactically calculated target coordinates matched both the known position of these targets in the phantom as well as the CT stereotactically calculated coordinates within approximately 1 mm. We also describe excellent superimposition of CT and MRI stereotactically determined surfaces in a recent clinical case using the new hardware. This shows that recent modifications to the CRW-MRI stereotactic system can make it accurate for small targets, but we emphasize that all systems need to undergo ongoing local quality assessment to ensure acceptable accuracy in practice. Copyright 2000 S. Karger AG, Basel

  4. The confidence-accuracy relationship in eyewitness identification: effects of lineup instructions, foil similarity, and target-absent base rates.

    PubMed

    Brewer, Neil; Wells, Gary L

    2006-03-01

    Discriminating accurate from mistaken eyewitness identifications is a major issue facing criminal justice systems. This study examined whether eyewitness confidence assists such decisions under a variety of conditions using a confidence-accuracy (CA) calibration approach. Participants (N = 1,200) viewed a simulated crime and attempted 2 separate identifications from 8-person target-present or target-absent lineups. Confidence and accuracy were calibrated for choosers (but not nonchoosers) for both targets under all conditions. Lower overconfidence was associated with higher diagnosticity, lower target-absent base rates, and shorter identification latencies. Although researchers agree that courtroom expressions of confidence are uninformative, our findings indicate that confidence assessments obtained immediately after a positive identification can provide a useful guide for investigators about the likely accuracy of an identification.

  5. Improving coding accuracy in an academic practice.

    PubMed

    Nguyen, Dana; O'Mara, Heather; Powell, Robert

    2017-01-01

    Practice management has become an increasingly important component of graduate medical education. This applies to every practice environment; private, academic, and military. One of the most critical aspects of practice management is documentation and coding for physician services, as they directly affect the financial success of any practice. Our quality improvement project aimed to implement a new and innovative method for teaching billing and coding in a longitudinal fashion in a family medicine residency. We hypothesized that implementation of a new teaching strategy would increase coding accuracy rates among residents and faculty. Design: single group, pretest-posttest. military family medicine residency clinic. Study populations: 7 faculty physicians and 18 resident physicians participated as learners in the project. Educational intervention: monthly structured coding learning sessions in the academic curriculum that involved learner-presented cases, small group case review, and large group discussion. overall coding accuracy (compliance) percentage and coding accuracy per year group for the subjects that were able to participate longitudinally. Statistical tests used: average coding accuracy for population; paired t test to assess improvement between 2 intervention periods, both aggregate and by year group. Overall coding accuracy rates remained stable over the course of time regardless of the modality of the educational intervention. A paired t test was conducted to compare coding accuracy rates at baseline (mean (M)=26.4%, SD=10%) to accuracy rates after all educational interventions were complete (M=26.8%, SD=12%); t24=-0.127, P=.90. Didactic teaching and small group discussion sessions did not improve overall coding accuracy in a residency practice. Future interventions could focus on educating providers at the individual level.

  6. Sound source localization identification accuracy: Envelope dependencies.

    PubMed

    Yost, William A

    2017-07-01

    Sound source localization accuracy as measured in an identification procedure in a front azimuth sound field was studied for click trains, modulated noises, and a modulated tonal carrier. Sound source localization accuracy was determined as a function of the number of clicks in a 64 Hz click train and click rate for a 500 ms duration click train. The clicks were either broadband or high-pass filtered. Sound source localization accuracy was also measured for a single broadband filtered click and compared to a similar broadband filtered, short-duration noise. Sound source localization accuracy was determined as a function of sinusoidal amplitude modulation and the "transposed" process of modulation of filtered noises and a 4 kHz tone. Different rates (16 to 512 Hz) of modulation (including unmodulated conditions) were used. Providing modulation for filtered click stimuli, filtered noises, and the 4 kHz tone had, at most, a very small effect on sound source localization accuracy. These data suggest that amplitude modulation, while providing information about interaural time differences in headphone studies, does not have much influence on sound source localization accuracy in a sound field.

  7. Greater trochanteric pain syndrome diagnosis and treatment.

    PubMed

    Mallow, Michael; Nazarian, Levon N

    2014-05-01

    Lateral hip pain, or greater trochanteric pain syndrome, is a commonly seen condition; in this article, the relevant anatomy, epidemiology, and evaluation strategies of greater trochanteric pain syndrome are reviewed. Specific attention is focused on imaging of this syndrome and treatment techniques, including ultrasound-guided interventions. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Effect of varying displays and room illuminance on caries diagnostic accuracy in digital dental radiographs.

    PubMed

    Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M

    2012-01-01

    In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.

  9. Results of a remote multiplexer/digitizer unit accuracy and environmental study

    NASA Technical Reports Server (NTRS)

    Wilner, D. O.

    1977-01-01

    A remote multiplexer/digitizer unit (RMDU), a part of the airborne integrated flight test data system, was subjected to an accuracy study. The study was designed to show the effects of temperature, altitude, and vibration on the RMDU. The RMDU was subjected to tests at temperatures from -54 C (-65 F) to 71 C (160 F), and the resulting data are presented here, along with a complete analysis of the effects. The methods and means used for obtaining correctable data and correcting the data are also discussed.

  10. Micro-surgical decompression for greater occipital neuralgia.

    PubMed

    Li, Fuyong; Ma, Yi; Zou, Jianjun; Li, Yanfeng; Wang, Bin; Huang, Haitao; Wang, Quancai; Li, Liang

    2012-01-01

    To evaluate the clinical effect of micro-surgical decompression of greater occipital nerve for greater occipital neuralgia (GON). 76 patients underwent surgical decompression of the great occipital nerve. A nerve block was tested before operation. The headache rapidly resolved after infiltration of 1% Lidocaine near the tender area of the nerve trunk. 89 procedures were performed for 76 patients. The mean follow up duration was 20 months (range 7-52 months). The headache symptoms of 68 (89.5%) patients were completely resolved, and another 5 (6.6%) patients were significantly relieved without the need for any further medical treatment. Three (3.9%) patients experienced recurrence of the disorder. All patients experienced hypoesthesia of the innervated area of the great occipital nerve. They recovered gradually within 1 to 6 months after surgery. Micro-surgical decompression of the greater occipital nerve is a safe and effective method for greater occipital neuralgia. We believe our findings support the notion that the technique should also be considered as the first-line procedure for GON.

  11. Effect of local magnetic field disturbances on inertial measurement units accuracy.

    PubMed

    Robert-Lachaine, Xavier; Mecheri, Hakim; Larue, Christian; Plamondon, André

    2017-09-01

    Inertial measurement units (IMUs), a practical motion analysis technology for field acquisition, have magnetometers to improve segment orientation estimation. However, sensitivity to magnetic disturbances can affect their accuracy. The objective of this study was to determine the joint angles accuracy of IMUs under different timing of magnetic disturbances of various durations and to evaluate a few correction methods. Kinematics from 12 individuals were obtained simultaneously with an Xsens system where an Optotrak cluster acting as the reference system was affixed to each IMU. A handling task was executed under normal laboratory conditions and imposed magnetic disturbances. Joint angle RMSE was used to conduct a three-way repeated measures analysis of variance in order to contrast the following disturbance factors: duration (0, 30, 60, 120 and 240 s), timing (during the disturbance, directly after it and a 30-second delay after it) and axis (X, Y and Z). The highest joint angle RMSE was observed on rotations about the Y longitudinal axis and during the longer disturbances. It stayed high directly after a disturbance, but returned close to baseline after a 30-second delay. When magnetic disturbances are experienced, waiting 30 s in a normal condition is recommended as a way to restore the IMUs' initial accuracy. The correction methods performed modestly or poorly in the reduction of joint angle RMSE. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Accuracy of analytic energy level formulas applied to hadronic spectroscopy of heavy mesons

    NASA Technical Reports Server (NTRS)

    Badavi, Forooz F.; Norbury, John W.; Wilson, John W.; Townsend, Lawrence W.

    1988-01-01

    Linear and harmonic potential models are used in the nonrelativistic Schroedinger equation to obtain article mass spectra for mesons as bound states of quarks. The main emphasis is on the linear potential where exact solutions of the S-state eigenvalues and eigenfunctions and the asymptotic solution for the higher order partial wave are obtained. A study of the accuracy of two analytical energy level formulas as applied to heavy mesons is also included. Cornwall's formula is found to be particularly accurate and useful as a predictor of heavy quarkonium states. Exact solution for all partial waves of eigenvalues and eigenfunctions for a harmonic potential is also obtained and compared with the calculated discrete spectra of the linear potential. Detailed derivations of the eigenvalues and eigenfunctions of the linear and harmonic potentials are presented in appendixes.

  13. Does the accuracy of blood pressure measurement correlate with hearing loss of the observer?

    PubMed

    Song, Soohwa; Lee, Jongshill; Chee, Youngjoon; Jang, Dong Pyo; Kim, In Young

    2014-02-01

    The auscultatory method is influenced by the hearing level of the observers. If the observer has hearing loss, it is possible to measure blood pressure inaccurately by misreading the Korotkoff sounds at systolic blood pressure (SBP) and diastolic blood pressure (DBP). Because of the potential clinical problems this discrepancy may cause, we used a hearing loss simulator to determine how hearing level affects the accuracy of blood pressure measurements. Two data sets (data set A, 32 Korotkoff sound video clips recorded by the British Hypertension Society; data set B, 28 Korotkoff sound data acquired from the Korotkoff sound recording system developed by Hanyang University) were used and all the data were attenuated to simulate a hearing loss of 5, 10, 15, 20, and 25 dB using the hearing loss simulator. Five observers with normal hearing assessed the blood pressures from these data sets and the differences between the values measured from the original recordings (no attenuation) and the attenuated versions were analyzed. Greater attenuation of the Korotkoff sounds, or greater hearing loss, resulted in larger blood pressure measurement differences when compared with the original data. When measuring blood pressure with hearing loss, the SBP tended to be underestimated and the DBP was overestimated. The mean differences between the original data and the 25 dB hearing loss data for the two data sets combined were 1.55±2.71 and -4.32±4.21 mmHg for SBP and DBP, respectively. This experiment showed that the accuracy of blood pressure measurements using the auscultatory method is affected by observer hearing level. Therefore, to reduce possible error using the auscultatory method, observers' hearing should be tested.

  14. Perceived Cost and Intrinsic Motor Variability Modulate the Speed-Accuracy Trade-Off

    PubMed Central

    Bertucco, Matteo; Bhanpuri, Nasir H.; Sanger, Terence D.

    2015-01-01

    Fitts’ Law describes the speed-accuracy trade-off of human movements, and it is an elegant strategy that compensates for random and uncontrollable noise in the motor system. The control strategy during targeted movements may also take into account the rewards or costs of any outcomes that may occur. The aim of this study was to test the hypothesis that movement time in Fitts’ Law emerges not only from the accuracy constraints of the task, but also depends on the perceived cost of error for missing the targets. Subjects were asked to touch targets on an iPad® screen with different costs for missed targets. We manipulated the probability of error by comparing children with dystonia (who are characterized by increased intrinsic motor variability) to typically developing children. The results show a strong effect of the cost of error on the Fitts’ Law relationship characterized by an increase in movement time as cost increased. In addition, we observed a greater sensitivity to increased cost for children with dystonia, and this behavior appears to minimize the average cost. The findings support a proposed mathematical model that explains how movement time in a Fitts-like task is related to perceived risk. PMID:26447874

  15. Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters.

    PubMed

    Tehrani, Joubin Nasehi; Yang, Yin; Werner, Rene; Lu, Wei; Low, Daniel; Guo, Xiaohu; Wang, Jing

    2015-11-21

    Finite element analysis (FEA)-based biomechanical modeling can be used to predict lung respiratory motion. In this technique, elastic models and biomechanical parameters are two important factors that determine modeling accuracy. We systematically evaluated the effects of lung and lung tumor biomechanical modeling approaches and related parameters to improve the accuracy of motion simulation of lung tumor center of mass (TCM) displacements. Experiments were conducted with four-dimensional computed tomography (4D-CT). A Quasi-Newton FEA was performed to simulate lung and related tumor displacements between end-expiration (phase 50%) and other respiration phases (0%, 10%, 20%, 30%, and 40%). Both linear isotropic and non-linear hyperelastic materials, including the neo-Hookean compressible and uncoupled Mooney-Rivlin models, were used to create a finite element model (FEM) of lung and tumors. Lung surface displacement vector fields (SDVFs) were obtained by registering the 50% phase CT to other respiration phases, using the non-rigid demons registration algorithm. The obtained SDVFs were used as lung surface displacement boundary conditions in FEM. The sensitivity of TCM displacement to lung and tumor biomechanical parameters was assessed in eight patients for all three models. Patient-specific optimal parameters were estimated by minimizing the TCM motion simulation errors between phase 50% and phase 0%. The uncoupled Mooney-Rivlin material model showed the highest TCM motion simulation accuracy. The average TCM motion simulation absolute errors for the Mooney-Rivlin material model along left-right, anterior-posterior, and superior-inferior directions were 0.80 mm, 0.86 mm, and 1.51 mm, respectively. The proposed strategy provides a reliable method to estimate patient-specific biomechanical parameters in FEM for lung tumor motion simulation.

  16. The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models.

    PubMed

    Maroua, Ahmad L; Ajaj, Mowaffak; Hajeer, Mohammad Y

    2016-04-01

    To evaluate the accuracy and reproducibility of linear measurements made on cone-beam computed tomography (CBCT)-derived digital models. A total of 25 patients (44% female, 18.7 ± 4 years) who had CBCT images for diagnostic purposes were included. Plaster models were obtained and digital models were extracted from CBCT scans. Seven linear measurements from predetermined landmarks were measured and analyzed on plaster models and the corresponding digital models. The measurements included arch length and width at different sites. Paired t test and Bland-Altman analysis were used to evaluate the accuracy of measurements on digital models compared to the plaster models. Also, intraclass correlation coefficients (ICCs) were used to evaluate the reproducibility of the measurements in order to assess the intraobserver reliability. The statistical analysis showed significant differences on 5 out of 14 variables, and the mean differences ranged from -0.48 to 0.51 mm. The Bland-Altman analysis revealed that the mean difference between variables was (0.14 ± 0.56) and (0.05 ± 0.96) mm and limits of agreement between the two methods ranged from -1.2 to 0.96 and from -1.8 to 1.9 mm in the maxilla and the mandible, respectively. The intraobserver reliability values were determined for all 14 variables of two types of models separately. The mean ICC value for the plaster models was 0.984 (0.924-0.999), while it was 0.946 for the CBCT models (range from 0.850 to 0.985). Linear measurements obtained from the CBCT-derived models appeared to have a high level of accuracy and reproducibility.

  17. Accuracy of plant specimen disease severity estimates: concepts, history, methods, ramifications and challenges for the future

    USDA-ARS?s Scientific Manuscript database

    Knowledge of the extent of the symptoms of a plant disease, generally referred to as severity, is key to both fundamental and applied aspects of plant pathology. Most commonly, severity is obtained visually and the accuracy of each estimate (closeness to the actual value) by individual raters is par...

  18. Automated method to differentiate between native and mirror protein models obtained from contact maps.

    PubMed

    Kurczynska, Monika; Kotulska, Malgorzata

    2018-01-01

    Mirror protein structures are often considered as artifacts in modeling protein structures. However, they may soon become a new branch of biochemistry. Moreover, methods of protein structure reconstruction, based on their residue-residue contact maps, need methodology to differentiate between models of native and mirror orientation, especially regarding the reconstructed backbones. We analyzed 130 500 structural protein models obtained from contact maps of 1 305 SCOP domains belonging to all 7 structural classes. On average, the same numbers of native and mirror models were obtained among 100 models generated for each domain. Since their structural features are often not sufficient for differentiating between the two types of model orientations, we proposed to apply various energy terms (ETs) from PyRosetta to separate native and mirror models. To automate the procedure for differentiating these models, the k-means clustering algorithm was applied. Using total energy did not allow to obtain appropriate clusters-the accuracy of the clustering for class A (all helices) was no more than 0.52. Therefore, we tested a series of different k-means clusterings based on various combinations of ETs. Finally, applying two most differentiating ETs for each class allowed to obtain satisfying results. To unify the method for differentiating between native and mirror models, independent of their structural class, the two best ETs for each class were considered. Finally, the k-means clustering algorithm used three common ETs: probability of amino acid assuming certain values of dihedral angles Φ and Ψ, Ramachandran preferences and Coulomb interactions. The accuracies of clustering with these ETs were in the range between 0.68 and 0.76, with sensitivity and selectivity in the range between 0.68 and 0.87, depending on the structural class. The method can be applied to all fully-automated tools for protein structure reconstruction based on contact maps, especially those analyzing

  19. Adjusting for partial verification or workup bias in meta-analyses of diagnostic accuracy studies.

    PubMed

    de Groot, Joris A H; Dendukuri, Nandini; Janssen, Kristel J M; Reitsma, Johannes B; Brophy, James; Joseph, Lawrence; Bossuyt, Patrick M M; Moons, Karel G M

    2012-04-15

    A key requirement in the design of diagnostic accuracy studies is that all study participants receive both the test under evaluation and the reference standard test. For a variety of practical and ethical reasons, sometimes only a proportion of patients receive the reference standard, which can bias the accuracy estimates. Numerous methods have been described for correcting this partial verification bias or workup bias in individual studies. In this article, the authors describe a Bayesian method for obtaining adjusted results from a diagnostic meta-analysis when partial verification or workup bias is present in a subset of the primary studies. The method corrects for verification bias without having to exclude primary studies with verification bias, thus preserving the main advantages of a meta-analysis: increased precision and better generalizability. The results of this method are compared with the existing methods for dealing with verification bias in diagnostic meta-analyses. For illustration, the authors use empirical data from a systematic review of studies of the accuracy of the immunohistochemistry test for diagnosis of human epidermal growth factor receptor 2 status in breast cancer patients.

  20. Comparison of polygraph data obtained from individuals involved in mock crimes and actual criminal investigations.

    PubMed

    Pollina, Dean A; Dollins, Andrew B; Senter, Stuart M; Krapohl, Donald J; Ryan, Andrew H

    2004-12-01

    In a preliminary attempt to determine the generalizability of data from laboratory mock-crime studies, the authors examined the similarities and differences among the cardiovascular, electrodermal, and respiration responses of deceptive and nondeceptive individuals elicited to crime-relevant and crime-irrelevant questions. Participants in the laboratory group were randomly assigned to nondeceptive (n = 28) or deceptive (n = 27) treatment groups, and a mock-crime scenario was used. The field participants were confirmed nondeceptive (n = 28) or deceptive (n = 39) criminal suspects who underwent polygraph examinations between 1993 and 1997. The results indicated that there were salient differences between field and similarly obtained laboratory polygraph response measures. However, accuracy of laboratory participants' classifications using logistic regression analysis was not significantly different from field participants' classification accuracy. 2004 APA, all rights reserved

  1. Thematic Accuracy Assessment of the 2011 National Land ...

    EPA Pesticide Factsheets

    Accuracy assessment is a standard protocol of National Land Cover Database (NLCD) mapping. Here we report agreement statistics between map and reference labels for NLCD 2011, which includes land cover for ca. 2001, ca. 2006, and ca. 2011. The two main objectives were assessment of agreement between map and reference labels for the three, single-date NLCD land cover products at Level II and Level I of the classification hierarchy, and agreement for 17 land cover change reporting themes based on Level I classes (e.g., forest loss; forest gain; forest, no change) for three change periods (2001–2006, 2006–2011, and 2001–2011). The single-date overall accuracies were 82%, 83%, and 83% at Level II and 88%, 89%, and 89% at Level I for 2011, 2006, and 2001, respectively. Many class-specific user's accuracies met or exceeded a previously established nominal accuracy benchmark of 85%. Overall accuracies for 2006 and 2001 land cover components of NLCD 2011 were approximately 4% higher (at Level II and Level I) than the overall accuracies for the same components of NLCD 2006. The high Level I overall, user's, and producer's accuracies for the single-date eras in NLCD 2011 did not translate into high class-specific user's and producer's accuracies for many of the 17 change reporting themes. User's accuracies were high for the no change reporting themes, commonly exceeding 85%, but were typically much lower for the reporting themes that represented change. Only forest l

  2. Mortality in NHS Greater Glasgow and Clyde employees: 2007-2009.

    PubMed

    Freer, K; Waclawski, E

    2013-09-01

    Just over a fifth of all deaths in Scotland occur in those under the age of 65. This study examined deaths in service in employees of the National Health Service Greater Glasgow and Clyde (NHS GG&C) Health Board over a 3-year period. To assess crude death rates by occupational group, the main causes of death and evidence of causes that could have been prevented or modified by lifestyle changes. Demographic details, occupational grouping and death certificate data were obtained for all NHS GG&C employees who died in service between 2007 and 2009. A total of 138 employees died in this period. The occupational groups in which most deaths occurred were support services (porters, domestic and catering staff; 35%) and nurses (34%). The commonest causes of death were lung cancer (15%), ischaemic heart disease (9%) and suicide (9%). The overall crude death rate was 1.2/1000 persons/year (females 1.0 and males 1.7) and was highest among support services employees (2.4) and lowest among medical staff (0.5). The relative risk of death in support services was significantly greater than the majority of occupational groups. These findings suggest health inequality within this workforce. The main causes of death identified in the support services group could potentially be modified through workplace risk factor screening and health promotion.

  3. Developing a Weighted Measure of Speech Sound Accuracy

    PubMed Central

    Preston, Jonathan L.; Ramsdell, Heather L.; Oller, D. Kimbrough; Edwards, Mary Louise; Tobin, Stephen J.

    2010-01-01

    Purpose The purpose is to develop a system for numerically quantifying a speaker’s phonetic accuracy through transcription-based measures. With a focus on normal and disordered speech in children, we describe a system for differentially weighting speech sound errors based on various levels of phonetic accuracy with a Weighted Speech Sound Accuracy (WSSA) score. We then evaluate the reliability and validity of this measure. Method Phonetic transcriptions are analyzed from several samples of child speech, including preschoolers and young adolescents with and without speech sound disorders and typically developing toddlers. The new measure of phonetic accuracy is compared to existing measures, is used to discriminate typical and disordered speech production, and is evaluated to determine whether it is sensitive to changes in phonetic accuracy over time. Results Initial psychometric data indicate that WSSA scores correlate with other measures of phonetic accuracy as well as listeners’ judgments of severity of a child’s speech disorder. The measure separates children with and without speech sound disorders. WSSA scores also capture growth in phonetic accuracy in toddler’s speech over time. Conclusion Results provide preliminary support for the WSSA as a valid and reliable measure of phonetic accuracy in children’s speech. PMID:20699344

  4. Accuracy of computerized automatic identification of cephalometric landmarks by a designed software.

    PubMed

    Shahidi, Sh; Shahidi, S; Oshagh, M; Gozin, F; Salehi, P; Danaei, S M

    2013-01-01

    The purpose of this study was to design software for localization of cephalometric landmarks and to evaluate its accuracy in finding landmarks. 40 digital cephalometric radiographs were randomly selected. 16 landmarks which were important in most cephalometric analyses were chosen to be identified. Three expert orthodontists manually identified landmarks twice. The mean of two measurements of each landmark was defined as the baseline landmark. The computer was then able to compare the automatic system's estimate of a landmark with the baseline landmark. The software was designed using Delphi and Matlab programming languages. The techniques were template matching, edge enhancement and some accessory techniques. The total mean error between manually identified and automatically identified landmarks was 2.59 mm. 12.5% of landmarks had mean errors less than 1 mm. 43.75% of landmarks had mean errors less than 2 mm. The mean errors of all landmarks except the anterior nasal spine were less than 4 mm. This software had significant accuracy for localization of cephalometric landmarks and could be used in future applications. It seems that the accuracy obtained with the software which was developed in this study is better than previous automated systems that have used model-based and knowledge-based approaches.

  5. High accuracy in short ISS missions

    NASA Astrophysics Data System (ADS)

    Rüeger, J. M.

    1986-06-01

    Traditionally Inertial Surveying Systems ( ISS) are used for missions of 30 km to 100 km length. Today, a new type of ISS application is emanating from an increased need for survey control densification in urban areas often in connection with land information systems or cadastral surveys. The accuracy requirements of urban surveys are usually high. The loss in accuracy caused by the coordinate transfer between IMU and ground marks is investigated and an offsetting system based on electronic tacheometers is proposed. An offsetting system based on a Hewlett-Packard HP 3820A electronic tacheometer has been tested in Sydney (Australia) in connection with a vehicle mounted LITTON Auto-Surveyor System II. On missions over 750 m ( 8 stations, 25 minutes duration, 3.5 minute ZUPT intervals, mean offset distances 9 metres) accuracies of 37 mm (one sigma) in position and 8 mm in elevation were achieved. Some improvements to the LITTON Auto-Surveyor System II are suggested which would improve the accuracies even further.

  6. Noise pollution mapping approach and accuracy on landscape scales.

    PubMed

    Iglesias Merchan, Carlos; Diaz-Balteiro, Luis

    2013-04-01

    Noise mapping allows the characterization of environmental variables, such as noise pollution or soundscape, depending on the task. Strategic noise mapping (as per Directive 2002/49/EC, 2002) is a tool intended for the assessment of noise pollution at the European level every five years. These maps are based on common methods and procedures intended for human exposure assessment in the European Union that could be also be adapted for assessing environmental noise pollution in natural parks. However, given the size of such areas, there could be an alternative approach to soundscape characterization rather than using human noise exposure procedures. It is possible to optimize the size of the mapping grid used for such work by taking into account the attributes of the area to be studied and the desired outcome. This would then optimize the mapping time and the cost. This type of optimization is important in noise assessment as well as in the study of other environmental variables. This study compares 15 models, using different grid sizes, to assess the accuracy of the noise mapping of the road traffic noise at a landscape scale, with respect to noise and landscape indicators. In a study area located in the Manzanares High River Basin Regional Park in Spain, different accuracy levels (Kappa index values from 0.725 to 0.987) were obtained depending on the terrain and noise source properties. The time taken for the calculations and the noise mapping accuracy results reveal the potential for setting the map resolution in line with decision-makers' criteria and budget considerations. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Diagnostic accuracy assessment of cytopathological examination of feline sporotrichosis.

    PubMed

    Jessica, N; Sonia, R L; Rodrigo, C; Isabella, D F; Tânia, M P; Jeferson, C; Anna, B F; Sandro, A

    2015-11-01

    Sporotrichosis is an implantation mycosis caused by pathogenic species of Sporothrix schenckii complex that affects humans and animals, especially cats. Its main forms of zoonotic transmission include scratching, biting and/or contact with the exudate from lesions of sick cats. In Brazil, epidemic involving humans, dogs and cats has occurred since 1998. The definitive diagnosis of sporotrichosis is obtained by the isolation of the fungus in culture; however, the result can take up to four weeks, which may delay the beginning of antifungal treatment in some cases. Cytopathological examination is often used in feline sporotrichosis diagnosis, but accuracy parameters have not been established yet. The aim of this study was to evaluate the accuracy and reliability of cytopathological examination in the diagnosis of feline sporotrichosis. The present study included 244 cats from the metropolitan region of Rio de Janeiro, mostly males in reproductive age with three or more lesions in non-adjacent anatomical places. To evaluate the inter-observer reliability, two different observers performed the microscopic examination of the slides blindly. Test sensitivity was 84.9%. The values of positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio and accuracy were 86.0, 24.4, 2.02, 0.26 and 82.8%, respectively. The reliability between the two observers was considered substantial. We conclude that the cytopathological examination is a sensitive, rapid and practical method to be used in feline sporotrichosis diagnosis in outbreaks of this mycosis. © The Author 2015. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  9. Modeling and Accuracy Assessment for 3D-VIRTUAL Reconstruction in Cultural Heritage Using Low-Cost Photogrammetry: Surveying of the "santa MARÍA Azogue" Church's Front

    NASA Astrophysics Data System (ADS)

    Robleda Prieto, G.; Pérez Ramos, A.

    2015-02-01

    Sometimes it could be difficult to represent "on paper" an architectural idea, a solution, a detail or a newly created element, depending on the complexity what it want be conveyed through its graphical representation but it may be even harder to represent the existing reality. (a building, a detail,...), at least with an acceptable degree of definition and accuracy. As a solution to this hypothetical problem, this paper try to show a methodology to collect measure data by combining different methods or techniques, to obtain the characteristic geometry of architectonic elements, especially in those highly decorated and/or complex geometry, as well as to assess the accuracy of the results obtained, but in an accuracy level enough and not very expensive costs. In addition, we can obtain a 3D recovery model that allows us a strong support, beyond point clouds obtained through another more expensive methods as using laser scanner, to obtain orthoimages. This methodology was used in the study case of the 3D-virtual reconstruction of a main medieval church façade because of the geometrical complexity in many elements as the existing main doorway with archivolts and many details, as well as the rose window located above it so it's inaccessible due to the height.

  10. Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review.

    PubMed

    Holm, Anne; Aabenhus, Rune

    2016-06-08

    Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection in primary care. The aim of this study was to determine the accuracy of urine culture from different sampling-techniques in symptomatic non-pregnant women in primary care. A systematic review was conducted by searching Medline and Embase for clinical studies conducted in primary care using a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. We included seven studies investigating urine sampling technique in 1062 symptomatic patients in primary care. Mid-stream-clean-catch had a positive predictive value of 0.79 to 0.95 and a negative predictive value close to 1 compared to sterile techniques. Two randomized controlled trials found no difference in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However, the evidence presented is in-direct and the difference between mid-stream-clean-catch, mid-stream-urine and random samples remains to be investigated in a paired design to verify the present findings.

  11. Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes

    PubMed Central

    Ding, Quan; Besio, Walter G.

    2015-01-01

    Conventional electroencephalography with disc electrodes has major drawbacks including poor spatial resolution, selectivity and low signal-to-noise ratio that are critically limiting its use. Concentric ring electrodes, consisting of several elements including the central disc and a number of concentric rings, are a promising alternative with potential to improve all of the aforementioned aspects significantly. In our previous work, the tripolar concentric ring electrode was successfully used in a wide range of applications demonstrating its superiority to conventional disc electrode, in particular, in accuracy of Laplacian estimation. This paper takes the next step toward further improving the Laplacian estimation with novel multipolar concentric ring electrodes by completing and validating a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2 that allows cancellation of all the truncation terms up to the order of 2n. An explicit formula based on inversion of a square Vandermonde matrix is derived to make computation of multipolar Laplacian more efficient. To confirm the analytic result of the accuracy of Laplacian estimate increasing with the increase of n and to assess the significance of this gain in accuracy for practical applications finite element method model analysis has been performed. Multipolar concentric ring electrode configurations with n ranging from 1 ring (bipolar electrode configuration) to 6 rings (septapolar electrode configuration) were directly compared and obtained results suggest the significance of the increase in Laplacian accuracy caused by increase of n. PMID:26693200

  12. Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes.

    PubMed

    Makeyev, Oleksandr; Ding, Quan; Besio, Walter G

    2016-02-01

    Conventional electroencephalography with disc electrodes has major drawbacks including poor spatial resolution, selectivity and low signal-to-noise ratio that are critically limiting its use. Concentric ring electrodes, consisting of several elements including the central disc and a number of concentric rings, are a promising alternative with potential to improve all of the aforementioned aspects significantly. In our previous work, the tripolar concentric ring electrode was successfully used in a wide range of applications demonstrating its superiority to conventional disc electrode, in particular, in accuracy of Laplacian estimation. This paper takes the next step toward further improving the Laplacian estimation with novel multipolar concentric ring electrodes by completing and validating a general approach to estimation of the Laplacian for an ( n + 1)-polar electrode with n rings using the (4 n + 1)-point method for n ≥ 2 that allows cancellation of all the truncation terms up to the order of 2 n . An explicit formula based on inversion of a square Vandermonde matrix is derived to make computation of multipolar Laplacian more efficient. To confirm the analytic result of the accuracy of Laplacian estimate increasing with the increase of n and to assess the significance of this gain in accuracy for practical applications finite element method model analysis has been performed. Multipolar concentric ring electrode configurations with n ranging from 1 ring (bipolar electrode configuration) to 6 rings (septapolar electrode configuration) were directly compared and obtained results suggest the significance of the increase in Laplacian accuracy caused by increase of n .

  13. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  14. Accuracy of CT-based attenuation correction in PET/CT bone imaging

    NASA Astrophysics Data System (ADS)

    Abella, Monica; Alessio, Adam M.; Mankoff, David A.; MacDonald, Lawrence R.; Vaquero, Juan Jose; Desco, Manuel; Kinahan, Paul E.

    2012-05-01

    We evaluate the accuracy of scaling CT images for attenuation correction of PET data measured for bone. While the standard tri-linear approach has been well tested for soft tissues, the impact of CT-based attenuation correction on the accuracy of tracer uptake in bone has not been reported in detail. We measured the accuracy of attenuation coefficients of bovine femur segments and patient data using a tri-linear method applied to CT images obtained at different kVp settings. Attenuation values at 511 keV obtained with a 68Ga/68Ge transmission scan were used as a reference standard. The impact of inaccurate attenuation images on PET standardized uptake values (SUVs) was then evaluated using simulated emission images and emission images from five patients with elevated levels of FDG uptake in bone at disease sites. The CT-based linear attenuation images of the bovine femur segments underestimated the true values by 2.9 ± 0.3% for cancellous bone regardless of kVp. For compact bone the underestimation ranged from 1.3% at 140 kVp to 14.1% at 80 kVp. In the patient scans at 140 kVp the underestimation was approximately 2% averaged over all bony regions. The sensitivity analysis indicated that errors in PET SUVs in bone are approximately proportional to errors in the estimated attenuation coefficients for the same regions. The variability in SUV bias also increased approximately linearly with the error in linear attenuation coefficients. These results suggest that bias in bone uptake SUVs of PET tracers ranges from 2.4% to 5.9% when using CT scans at 140 and 120 kVp for attenuation correction. Lower kVp scans have the potential for considerably more error in dense bone. This bias is present in any PET tracer with bone uptake but may be clinically insignificant for many imaging tasks. However, errors from CT-based attenuation correction methods should be carefully evaluated if quantitation of tracer uptake in bone is important.

  15. SU-E-T-291: Dosimetric Accuracy of Multitarget Single Isocenter Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tannazi, F; Huang, M; Thomas, E

    2015-06-15

    Purpose: To evaluate the accuracy of single-isocenter multiple-target VMAT radiosurgery (SIMT-VMAT-SRS) by analysis of pre-treatment verification measurements. Methods: Our QA procedure used a phantom having a coronal plane for EDR2 film and a 0.125 cm3 ionization chamber. Film measurements were obtained for the largest and smallest targets for each plan. An ionization chamber measurement (ICM) was obtained for sufficiently large targets. Films were converted to dose using a patient-specific calibration curve and compared to treatment planning system calculations. Alignment error was estimated using image registration. The gamma index was calculated for 3%/3 and 3%/1 mm criteria. The median dose inmore » the target region and, for plans having an ICM, the average dose in the central 5 mm was calculated. Results: The average equivalent target diameter of the 48 targets was 15 mm (3–43 mm). Twenty of the 24 plans had an ICM for the plan corresponding to the largest target (diameter 11–43 mm) with a mean ratio of chamber reading to expected dose (ED) and the mean ratio of film to ED (averaged over the central 5 mm) was 1.001 (0.025 SD) and 1.000 (0.029 SD), respectively. For all plans, the mean film to ED (from the median dose in the target region) was 0.997 (0.027 SD). The mean registration vector was (0.15,0.29) mm, with an average magnitude of 0.96 mm. Before (after) registration, the average fraction of pixels having gamma < 1 was 99.3% (99.6%) and 89.1% (97.6%) for 3%/3mm and 3%/1mm, respectively. Conclusion: Our results demonstrate dosimetric accuracy of SIMT-VMAT-SRS for targets as small as 3 mm. Film dosimetry provides accurate assessment of the absolute dose delivered to targets too small for an ionization chamber measurement; however, the relatively large registration vector indicates that image-guidance should replace laser-based setup for patient-specific evaluation of geometric accuracy.« less

  16. Multicenter accuracy and interobserver agreement of spot sign identification in acute intracerebral hemorrhage.

    PubMed

    Huynh, Thien J; Flaherty, Matthew L; Gladstone, David J; Broderick, Joseph P; Demchuk, Andrew M; Dowlatshahi, Dar; Meretoja, Atte; Davis, Stephen M; Mitchell, Peter J; Tomlinson, George A; Chenkin, Jordan; Chia, Tze L; Symons, Sean P; Aviv, Richard I

    2014-01-01

    Rapid, accurate, and reliable identification of the computed tomography angiography spot sign is required to identify patients with intracerebral hemorrhage for trials of acute hemostatic therapy. We sought to assess the accuracy and interobserver agreement for spot sign identification. A total of 131 neurology, emergency medicine, and neuroradiology staff and fellows underwent imaging certification for spot sign identification before enrolling patients in 3 trials targeting spot-positive intracerebral hemorrhage for hemostatic intervention (STOP-IT, SPOTLIGHT, STOP-AUST). Ten intracerebral hemorrhage cases (spot-positive/negative ratio, 1:1) were presented for evaluation of spot sign presence, number, and mimics. True spot positivity was determined by consensus of 2 experienced neuroradiologists. Diagnostic performance, agreement, and differences by training level were analyzed. Mean accuracy, sensitivity, and specificity for spot sign identification were 87%, 78%, and 96%, respectively. Overall sensitivity was lower than specificity (P<0.001) because of true spot signs incorrectly perceived as spot mimics. Interobserver agreement for spot sign presence was moderate (k=0.60). When true spots were correctly identified, 81% correctly identified the presence of single or multiple spots. Median time needed to evaluate the presence of a spot sign was 1.9 minutes (interquartile range, 1.2-3.1 minutes). Diagnostic performance, interobserver agreement, and time needed for spot sign evaluation were similar among staff physicians and fellows. Accuracy for spot identification is high with opportunity for improvement in spot interpretation sensitivity and interobserver agreement particularly through greater reliance on computed tomography angiography source data and awareness of limitations of multiplanar images. Further prospective study is needed.

  17. Get the Diagnosis: an evidence-based medicine collaborative Wiki for diagnostic test accuracy.

    PubMed

    Hammer, Mark M; Kohlberg, Gavriel D

    2017-04-01

    Despite widespread calls for its use, there are challenges to the implementation of evidence-based medicine (EBM) in clinical practice. In response to the challenges of finding timely, pertinent information on diagnostic test accuracy, we developed an online, crowd-sourced Wiki on diagnostic test accuracy called Get the Diagnosis (GTD, http://www.getthediagnosis.org). Since its launch in November 2008 till October 2015, GTD has accumulated information on 300 diagnoses, with 1617 total diagnostic entries. There are a total of 1097 unique diagnostic tests with a mean of 5.4 tests (range 0-38) per diagnosis. 73% of entries (1182 of 1617) have an associated sensitivity and specificity and 89% of entries (1432 of 1617) have associated peer-reviewed literature citations. Altogether, GTD contains 474 unique literature citations. For a sample of three diagnoses, the search precision (percentage of relevant results in the first 30 entries) in GTD was 100% as compared with a range of 13.3%-63.3% for PubMed and between 6.7% and 76.7% for Google Scholar. GTD offers a fast, precise and efficient way to look up diagnostic test accuracy. On three selected examples, GTD had a greater precision rate compared with PubMed and Google Scholar in identifying diagnostic test information. GTD is a free resource that complements other currently available resources. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Dimensional accuracy of aluminium extrusions in mechanical calibration

    NASA Astrophysics Data System (ADS)

    Raknes, Christian Arne; Welo, Torgeir; Paulsen, Frode

    2018-05-01

    Reducing dimensional variations in the extrusion process without increasing cost is challenging due to the nature of the process itself. An alternative approach—also from a cost perspective—is using extruded profiles with standard tolerances and utilize downstream processes, and thus calibrate the part within tolerance limits that are not achievable directly from the extrusion process. In this paper, two mechanical calibration strategies for the extruded product are investigated, utilizing the forming lines of the manufacturer. The first calibration strategy is based on global, longitudinal stretching in combination with local bending, while the second strategy utilizes the principle of transversal stretching and local bending of the cross-section. An extruded U-profile is used to make a comparison between the two methods using numerical analyses. To provide response surfaces with the FEA program, ABAQUS is used in combination with Design of Experiment (DOE). DOE is conducted with a two-level fractional factorial design to collect the appropriate data. The aim is to find the main factors affecting the dimension accuracy of the final part obtained by the two calibration methods. The results show that both calibration strategies have proven to reduce cross-sectional variations effectively form standard extrusion tolerances. It is concluded that mechanical calibration is a viable, low-cost alternative for aluminium parts that demand high dimensional accuracy, e.g. due to fit-up or welding requirements.

  19. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions - Effect of Velocity

    PubMed Central

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2013-01-01

    Background Inertial measurement of motion with Attitude and Heading Reference Systems (AHRS) is emerging as an alternative to 3D motion capture systems in biomechanics. The objectives of this study are: 1) to describe the absolute and relative accuracy of multiple units of commercially available AHRS under various types of motion; and 2) to evaluate the effect of motion velocity on the accuracy of these measurements. Methods The criterion validity of accuracy was established under controlled conditions using an instrumented Gimbal table. AHRS modules were carefully attached to the center plate of the Gimbal table and put through experimental static and dynamic conditions. Static and absolute accuracy was assessed by comparing the AHRS orientation measurement to those obtained using an optical gold standard. Relative accuracy was assessed by measuring the variation in relative orientation between modules during trials. Findings Evaluated AHRS systems demonstrated good absolute static accuracy (mean error < 0.5o) and clinically acceptable absolute accuracy under condition of slow motions (mean error between 0.5o and 3.1o). In slow motions, relative accuracy varied from 2o to 7o depending on the type of AHRS and the type of rotation. Absolute and relative accuracy were significantly affected (p<0.05) by velocity during sustained motions. The extent of that effect varied across AHRS. Interpretation Absolute and relative accuracy of AHRS are affected by environmental magnetic perturbations and conditions of motions. Relative accuracy of AHRS is mostly affected by the ability of all modules to locate the same global reference coordinate system at all time. Conclusions Existing AHRS systems can be considered for use in clinical biomechanics under constrained conditions of use. While their individual capacity to track absolute motion is relatively consistent, the use of multiple AHRS modules to compute relative motion between rigid bodies needs to be optimized according to

  20. Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes: A systematic review.

    PubMed

    Rossini, Gabriele; Parrini, Simone; Castroflorio, Tommaso; Deregibus, Andrea; Debernardi, Cesare L

    2016-02-01

    Our objective was to assess the accuracy, validity, and reliability of measurements obtained from virtual dental study models compared with those obtained from plaster models. PubMed, PubMed Central, National Library of Medicine Medline, Embase, Cochrane Central Register of Controlled Clinical trials, Web of Knowledge, Scopus, Google Scholar, and LILACs were searched from January 2000 to November 2014. A grading system described by the Swedish Council on Technology Assessment in Health Care and the Cochrane tool for risk of bias assessment were used to rate the methodologic quality of the articles. Thirty-five relevant articles were selected. The methodologic quality was high. No significant differences were observed for most of the studies in all the measured parameters, with the exception of the American Board of Orthodontics Objective Grading System. Digital models are as reliable as traditional plaster models, with high accuracy, reliability, and reproducibility. Landmark identification, rather than the measuring device or the software, appears to be the greatest limitation. Furthermore, with their advantages in terms of cost, time, and space required, digital models could be considered the new gold standard in current practice. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Comparison of wheat classification accuracy using different classifiers of the image-100 system

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N. (Principal Investigator); Chen, S. C.; Moreira, M. A.; Delima, A. M.

    1981-01-01

    Classification results using single-cell and multi-cell signature acquisition options, a point-by-point Gaussian maximum-likelihood classifier, and K-means clustering of the Image-100 system are presented. Conclusions reached are that: a better indication of correct classification can be provided by using a test area which contains various cover types of the study area; classification accuracy should be evaluated considering both the percentages of correct classification and error of commission; supervised classification approaches are better than K-means clustering; Gaussian distribution maximum likelihood classifier is better than Single-cell and Multi-cell Signature Acquisition Options of the Image-100 system; and in order to obtain a high classification accuracy in a large and heterogeneous crop area, using Gaussian maximum-likelihood classifier, homogeneous spectral subclasses of the study crop should be created to derive training statistics.

  2. Increasing Accuracy in Computed Inviscid Boundary Conditions

    NASA Technical Reports Server (NTRS)

    Dyson, Roger

    2004-01-01

    A technique has been devised to increase the accuracy of computational simulations of flows of inviscid fluids by increasing the accuracy with which surface boundary conditions are represented. This technique is expected to be especially beneficial for computational aeroacoustics, wherein it enables proper accounting, not only for acoustic waves, but also for vorticity and entropy waves, at surfaces. Heretofore, inviscid nonlinear surface boundary conditions have been limited to third-order accuracy in time for stationary surfaces and to first-order accuracy in time for moving surfaces. For steady-state calculations, it may be possible to achieve higher accuracy in space, but high accuracy in time is needed for efficient simulation of multiscale unsteady flow phenomena. The present technique is the first surface treatment that provides the needed high accuracy through proper accounting of higher-order time derivatives. The present technique is founded on a method known in art as the Hermitian modified solution approximation (MESA) scheme. This is because high time accuracy at a surface depends upon, among other things, correction of the spatial cross-derivatives of flow variables, and many of these cross-derivatives are included explicitly on the computational grid in the MESA scheme. (Alternatively, a related method other than the MESA scheme could be used, as long as the method involves consistent application of the effects of the cross-derivatives.) While the mathematical derivation of the present technique is too lengthy and complex to fit within the space available for this article, the technique itself can be characterized in relatively simple terms: The technique involves correction of surface-normal spatial pressure derivatives at a boundary surface to satisfy the governing equations and the boundary conditions and thereby achieve arbitrarily high orders of time accuracy in special cases. The boundary conditions can now include a potentially infinite number

  3. Stereotype Accuracy: Toward Appreciating Group Differences.

    ERIC Educational Resources Information Center

    Lee, Yueh-Ting, Ed.; And Others

    The preponderance of scholarly theory and research on stereotypes assumes that they are bad and inaccurate, but understanding stereotype accuracy and inaccuracy is more interesting and complicated than simpleminded accusations of racism or sexism would seem to imply. The selections in this collection explore issues of the accuracy of stereotypes…

  4. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  5. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  6. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  7. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  8. 40 CFR 92.127 - Emission measurement accuracy.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...

  9. Improved accuracies for satellite tracking

    NASA Technical Reports Server (NTRS)

    Kammeyer, P. C.; Fiala, A. D.; Seidelmann, P. K.

    1991-01-01

    A charge coupled device (CCD) camera on an optical telescope which follows the stars can be used to provide high accuracy comparisons between the line of sight to a satellite, over a large range of satellite altitudes, and lines of sight to nearby stars. The CCD camera can be rotated so the motion of the satellite is down columns of the CCD chip, and charge can be moved from row to row of the chip at a rate which matches the motion of the optical image of the satellite across the chip. Measurement of satellite and star images, together with accurate timing of charge motion, provides accurate comparisons of lines of sight. Given lines of sight to stars near the satellite, the satellite line of sight may be determined. Initial experiments with this technique, using an 18 cm telescope, have produced TDRS-4 observations which have an rms error of 0.5 arc second, 100 m at synchronous altitude. Use of a mosaic of CCD chips, each having its own rate of charge motion, in the focal place of a telescope would allow point images of a geosynchronous satellite and of stars to be formed simultaneously in the same telescope. The line of sight of such a satellite could be measured relative to nearby star lines of sight with an accuracy of approximately 0.03 arc second. Development of a star catalog with 0.04 arc second rms accuracy and perhaps ten stars per square degree would allow determination of satellite lines of sight with 0.05 arc second rms absolute accuracy, corresponding to 10 m at synchronous altitude. Multiple station time transfers through a communications satellite can provide accurate distances from the satellite to the ground stations. Such observations can, if calibrated for delays, determine satellite orbits to an accuracy approaching 10 m rms.

  10. [Accuracy of a pulse oximeter during hypoxia].

    PubMed

    Tachibana, C; Fukada, T; Hasegawa, R; Satoh, K; Furuya, Y; Ohe, Y

    1996-04-01

    The accuracy of the pulse oximeter was examined in hypoxic patients. We studied 11 cyanotic congenital heart disease patients during surgery, and compared the arterial oxygen saturation determined by both the simultaneous blood gas analysis (CIBA-CORNING 288 BLOOD GAS SYSTEM, SaO2) and by the pulse oximeter (DATEX SATELITE, with finger probe, SpO2). Ninty sets of data on SpO2 and SaO2 were obtained. The bias (SpO2-SaO2) was 1.7 +/- 6.9 (mean +/- SD) %. In cyanotic congenital heart disease patients, SpO2 values were significantly higher than SaO2. Although the reason is unknown, in constantly hypoxic patients, SpO2 values are possibly over-estimated. In particular, pulse oximetry at low levels of saturation (SaO2 below 80%) was not as accurate as at a higher saturation level (SaO2 over 80%). There was a positive correlation between SpO2 and SaO2 (linear regression analysis yields the equation y = 0.68x + 26.0, r = 0.93). In conclusion, the pulse oximeter is useful to monitor oxygen saturation in constantly hypoxic patients, but the values thus obtained should be compared with the values measured directly when hypoxemia is severe.

  11. Angular Resolution of an EAS Array for Gamma Ray Astronomy at Energies Greater Than 5 x 10 (13) Ev

    NASA Technical Reports Server (NTRS)

    Apte, A. R.; Gopalakrishnan, N. V.; Tonwar, S. C.; Uma, V.

    1985-01-01

    A 24 detector extensive air shower array is being operated at Ootacamund (2300 m altitude, 11.4 deg N latitude) in southern India for a study of arrival directions of showers of energies greater than 5 x 10 to the 13th power eV. Various configurations of the array of detectors have been used to estimate the accuracy in determination of arrival angle of showers with such an array. These studies show that it is possible to achieve an angular resolution of better than 2 deg with the Ooty array for search for point sources of Cosmic gamma rays at energies above 5 x 10 to the 13th power eV.

  12. Developing a weighted measure of speech sound accuracy.

    PubMed

    Preston, Jonathan L; Ramsdell, Heather L; Oller, D Kimbrough; Edwards, Mary Louise; Tobin, Stephen J

    2011-02-01

    To develop a system for numerically quantifying a speaker's phonetic accuracy through transcription-based measures. With a focus on normal and disordered speech in children, the authors describe a system for differentially weighting speech sound errors on the basis of various levels of phonetic accuracy using a Weighted Speech Sound Accuracy (WSSA) score. The authors then evaluate the reliability and validity of this measure. Phonetic transcriptions were analyzed from several samples of child speech, including preschoolers and young adolescents with and without speech sound disorders and typically developing toddlers. The new measure of phonetic accuracy was validated against existing measures, was used to discriminate typical and disordered speech production, and was evaluated to examine sensitivity to changes in phonetic accuracy over time. Reliability between transcribers and consistency of scores among different word sets and testing points are compared. Initial psychometric data indicate that WSSA scores correlate with other measures of phonetic accuracy as well as listeners' judgments of the severity of a child's speech disorder. The measure separates children with and without speech sound disorders and captures growth in phonetic accuracy in toddlers' speech over time. The measure correlates highly across transcribers, word lists, and testing points. Results provide preliminary support for the WSSA as a valid and reliable measure of phonetic accuracy in children's speech.

  13. Anatomical accuracy of brain connections derived from diffusion MRI tractography is inherently limited.

    PubMed

    Thomas, Cibu; Ye, Frank Q; Irfanoglu, M Okan; Modi, Pooja; Saleem, Kadharbatcha S; Leopold, David A; Pierpaoli, Carlo

    2014-11-18

    Tractography based on diffusion-weighted MRI (DWI) is widely used for mapping the structural connections of the human brain. Its accuracy is known to be limited by technical factors affecting in vivo data acquisition, such as noise, artifacts, and data undersampling resulting from scan time constraints. It generally is assumed that improvements in data quality and implementation of sophisticated tractography methods will lead to increasingly accurate maps of human anatomical connections. However, assessing the anatomical accuracy of DWI tractography is difficult because of the lack of independent knowledge of the true anatomical connections in humans. Here we investigate the future prospects of DWI-based connectional imaging by applying advanced tractography methods to an ex vivo DWI dataset of the macaque brain. The results of different tractography methods were compared with maps of known axonal projections from previous tracer studies in the macaque. Despite the exceptional quality of the DWI data, none of the methods demonstrated high anatomical accuracy. The methods that showed the highest sensitivity showed the lowest specificity, and vice versa. Additionally, anatomical accuracy was highly dependent upon parameters of the tractography algorithm, with different optimal values for mapping different pathways. These results suggest that there is an inherent limitation in determining long-range anatomical projections based on voxel-averaged estimates of local fiber orientation obtained from DWI data that is unlikely to be overcome by improvements in data acquisition and analysis alone.

  14. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    PubMed

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the

  15. Diagnostic accuracy of a bayesian latent group analysis for the detection of malingering-related poor effort.

    PubMed

    Ortega, Alonso; Labrenz, Stephan; Markowitsch, Hans J; Piefke, Martina

    2013-01-01

    In the last decade, different statistical techniques have been introduced to improve assessment of malingering-related poor effort. In this context, we have recently shown preliminary evidence that a Bayesian latent group model may help to optimize classification accuracy using a simulation research design. In the present study, we conducted two analyses. Firstly, we evaluated how accurately this Bayesian approach can distinguish between participants answering in an honest way (honest response group) and participants feigning cognitive impairment (experimental malingering group). Secondly, we tested the accuracy of our model in the differentiation between patients who had real cognitive deficits (cognitively impaired group) and participants who belonged to the experimental malingering group. All Bayesian analyses were conducted using the raw scores of a visual recognition forced-choice task (2AFC), the Test of Memory Malingering (TOMM, Trial 2), and the Word Memory Test (WMT, primary effort subtests). The first analysis showed 100% accuracy for the Bayesian model in distinguishing participants of both groups with all effort measures. The second analysis showed outstanding overall accuracy of the Bayesian model when estimates were obtained from the 2AFC and the TOMM raw scores. Diagnostic accuracy of the Bayesian model diminished when using the WMT total raw scores. Despite, overall diagnostic accuracy can still be considered excellent. The most plausible explanation for this decrement is the low performance in verbal recognition and fluency tasks of some patients of the cognitively impaired group. Additionally, the Bayesian model provides individual estimates, p(zi |D), of examinees' effort levels. In conclusion, both high classification accuracy levels and Bayesian individual estimates of effort may be very useful for clinicians when assessing for effort in medico-legal settings.

  16. Obtaining Reliable Estimates of Ambulatory Physical Activity in People with Parkinson's Disease.

    PubMed

    Paul, Serene S; Ellis, Terry D; Dibble, Leland E; Earhart, Gammon M; Ford, Matthew P; Foreman, K Bo; Cavanaugh, James T

    2016-05-05

    We determined the number of days required, and whether to include weekdays and/or weekends, to obtain reliable measures of ambulatory physical activity in people with Parkinson's disease (PD). Ninety-two persons with PD wore a step activity monitor for seven days. The number of days required to obtain a reliable estimate of daily activity was determined from the mean intraclass correlation (ICC2,1) for all possible combinations of 1-6 consecutive days of monitoring. Two days of monitoring were sufficient to obtain reliable daily activity estimates (ICC2,1 > 0.9). Amount (p = 0.03) but not intensity (p = 0.13) of ambulatory activity was greater on weekdays than weekends. Activity prescription based on amount rather than intensity may be more appropriate for people with PD.

  17. Possibilities for Using LIDAR and Photogrammetric Data Obtained with AN Unmanned Aerial Vehicle for Levee Monitoring

    NASA Astrophysics Data System (ADS)

    Bakuła, K.; Ostrowski, W.; Szender, M.; Plutecki, W.; Salach, A.; Górski, K.

    2016-06-01

    This paper presents the possibilities for using an unmanned aerial system for evaluation of the condition of levees. The unmanned aerial system is equipped with two types of sensor. One is an ultra-light laser scanner, integrated with a GNSS receiver and an INS system; the other sensor is a digital camera that acquires data with stereoscopic coverage. Sensors have been mounted on the multirotor, unmanned platform the Hawk Moth, constructed by MSP company. LiDAR data and images of levees the length of several hundred metres were acquired during testing of the platform. Flights were performed in several variants. Control points measured with the use of the GNSS technique were considered as reference data. The obtained results are presented in this paper; the methodology of processing the acquired LiDAR data, which increase in accuracy when low accuracy of the navigation systems occurs as a result of systematic errors, is also discussed. The Iterative Closest Point (ICP) algorithm, as well as measurements of control points, were used to georeference the LiDAR data. Final accuracy in the order of centimetres was obtained for generation of the digital terrain model. The final products of the proposed UAV data processing are digital elevation models, an orthophotomap and colour point clouds. The authors conclude that such a platform offers wide possibilities for low-budget flights to deliver the data, which may compete with typical direct surveying measurements performed during monitoring of such objects. However, the biggest advantage is the density and continuity of data, which allows for detection of changes in objects being monitored.

  18. Diffusion Tensor Imaging in Chronic Inflammatory Demyelinating Polyneuropathy: Diagnostic Accuracy and Correlation With Electrophysiology.

    PubMed

    Kronlage, Moritz; Pitarokoili, Kalliopi; Schwarz, Daniel; Godel, Tim; Heiland, Sabine; Yoon, Min-Suk; Bendszus, Martin; Bäumer, Philipp

    2017-11-01

    The aims of this study were to assess diagnostic accuracy of diffusion tensor imaging (DTI) in chronic inflammatory demyelinating polyneuropathy (CIDP), to correlate DTI with electrophysiological parameters, and to evaluate whether radial diffusivity (RD) and axial diffusivity (AD) might serve as specific biomarkers of demyelinating and axonal pathology. This prospective study was approved by the institutional ethics committee, and written informed consent was obtained from all participants. Magnetic resonance neurography of upper and lower extremity nerves (median, ulnar, radial, sciatic, tibial) was performed by single-shot DTI sequences at 3.0 T in 18 patients with a diagnosis of CIDP and 18 healthy controls, matched to age and sex. The scalar readout parameters nerve fractional anisotropy (FA), mean diffusivity (MD), RD, and AD were obtained after manual segmentation and postprocessing and compared between patients and controls. Diagnostic accuracy was assessed by receiver operating characteristic analysis, and cutoff values were calculated by maximizing the Youden index. All patients underwent a complementary electroneurography and correlation of electrophysiological markers and DTI parameters was analyzed and described by Pearson and Spearman coefficients. Nerve FA was decreased to a mean of 0.42 ± 0.08 in patients compared with 0.52 ± 0.04 in healthy controls (P < 0.001). This decrease in FA was a result of an increase of RD (P = 0.02), whereas AD did not differ between the two groups. Of all DTI parameters, FA showed best diagnostic accuracy with a receiver operating characteristic area under the curve of 0.90. Optimal cutoff for an average FA of all analyzed nerves was 0.47, yielding a sensitivity of 0.83 and a specificity of 0.94. Fractional anisotropy and RD correlated strongly with electrophysiological markers of demyelination, whereas AD did not correlate with markers of axonal neuropathy. Diffusion tensor imaging yields valid quantitative biomarkers

  19. Evaluation of the genetic distinctiveness of Greater Sage-grouse in the Bi-State Planning Area

    USGS Publications Warehouse

    Oyler-McCance, Sara J.; Casazza, Michael L.

    2011-01-01

    The purpose of this study was to further characterize a distinct population of Greater Sage-grouse: the population located along the border between Nevada and California (Bi-State Planning Area) and centered around the Mono Basin. This population was previously determined to be genetically distinct from other Greater Sage-grouse populations across their range. Previous genetic work focused on characterizing genetic variation across the species' range and thereby used a coarse sampling approach for species characterization. The goal of this study was to investigate this population further by obtaining samples from breeding locations within the population and analyzing those samples with the same mitochondrial and microsatellite loci used in previous studies. Blood samples were collected in six locations within the Bi-State Planning Area. Genetic data from subpopulations were then compared with each other and also with two populations outside of the Bi-State Planning Area. Particular attention was paid to subpopulation boundaries and internal dynamics by drawing comparisons among particular regions within the Bi-State Planning Area and regions proximal to it. All newly sampled subpopulations contained mitochondrial haplotypes and allele frequencies that were consistent with the genetically unique Bi-State (Mono Basin) Greater Sage-grouse described previously. This reinforces the fact that this group of Greater Sage-grouse is genetically unique and warrants special attention. Maintaining the genetic integrity of this population could protect the evolutionary potential of this population of Greater Sage-grouse. Additionally, the White Mountains subpopulation was found to be significantly distinct from all other Bi-State subpopulations.

  20. The Influence of Green Infrastructure on Urban Resilience in Greater London

    NASA Astrophysics Data System (ADS)

    Oh, Yukyung

    2017-04-01

    High population densities and diverse economic activities in urban areas create social issues as well as a range of environmental impacts including air pollution, soil contamination, loss of biodiversity and health problems (Alberti et al., 2003; Dobbs, Escobedo, & Zipperer, 2011; Grimm et al., 2008). The concept of urban resilience has been used for increasing the capacity of the entities and players to adapt to rapid changes, and urban green spaces play a crucial role in increasing urban resilience. Greater London has a good case for increasing urban green spaces and resilience under the London Plan. The relevance of urban open spaces and several socioeconomic indicators would provide researchers and policy makers with the information for managing green coverage. The correlation analysis of two quantitative data such as open space and socioeconomic data of Greater London was conducted with SPSS. The data for open spaces in Greater London was gained through Greenspace Information for Greater London. The data was converted from vector to raster in Geographic Information System (GIS), so as to calculate landscape metrics for open spaces in Greater London through a spatial pattern analysis program, FRAGSTATS 4.2. The socioeconomic data was obtained from "London Borough Profile", London Datastore. In addition, data on total carbon emissions from Industry and Commercial, Domestic, Transport, LULUCF Net Emissions, and per capita emissions were gained from UK local authority and regional carbon dioxide emissions national statistics: 2005-2014 released from Department of Energy and Climate Change. The indicators from open spaces are total area of open space and patch density or contagion of open spaces. The latter indicator allows to figure out the level of fragmentation of open spaces. The socioeconomic indicators cover number of jobs by workplace, jobs density, crime rates per thousand population, and several wellbeing indicators such as life satisfaction