Sample records for obtain quantitative values

  1. Remote measurement of water color in coastal waters. [spectral radiance data used to obtain quantitative values for chlorophyll and turbidity

    NASA Technical Reports Server (NTRS)

    Weldon, J. W.

    1973-01-01

    An investigation was conducted to develop procedure to obtain quantitative values for chlorophyll and turbidity in coastal waters by observing the changes in spectral radiance of the backscattered spectrum. The technique under consideration consists of Examining Exotech model 20-D spectral radiometer data and determining which radiance ratios best correlated with chlorophyll and turbidity measurements as obtained from analyses of water samples and sechi visibility readings. Preliminary results indicate that there is a correlation between backscattered light and chlorophyll concentration and secchi visibility. The tests were conducted with the spectrometer mounted in a light aircraft over the Mississippi Sound at altitudes of 2.5K, 2.8K and 10K feet.

  2. Propagating Qualitative Values Through Quantitative Equations

    NASA Technical Reports Server (NTRS)

    Kulkarni, Deepak

    1992-01-01

    In most practical problems where traditional numeric simulation is not adequate, one need to reason about a system with both qualitative and quantitative equations. In this paper, we address the problem of propagating qualitative values represented as interval values through quantitative equations. Previous research has produced exponential-time algorithms for approximate solution of the problem. These may not meet the stringent requirements of many real time applications. This paper advances the state of art by producing a linear-time algorithm that can propagate a qualitative value through a class of complex quantitative equations exactly and through arbitrary algebraic expressions approximately. The algorithm was found applicable to Space Shuttle Reaction Control System model.

  3. Mapping Bone Mineral Density Obtained by Quantitative Computed Tomography to Bone Volume Fraction

    NASA Technical Reports Server (NTRS)

    Pennline, James A.; Mulugeta, Lealem

    2017-01-01

    Methods for relating or mapping estimates of volumetric Bone Mineral Density (vBMD) obtained by Quantitative Computed Tomography to Bone Volume Fraction (BVF) are outlined mathematically. The methods are based on definitions of bone properties, cited experimental studies and regression relations derived from them for trabecular bone in the proximal femur. Using an experimental range of values in the intertrochanteric region obtained from male and female human subjects, age 18 to 49, the BVF values calculated from four different methods were compared to the experimental average and numerical range. The BVF values computed from the conversion method used data from two sources. One source provided pre bed rest vBMD values in the intertrochanteric region from 24 bed rest subject who participated in a 70 day study. Another source contained preflight vBMD values from 18 astronauts who spent 4 to 6 months on the ISS. To aid the use of a mapping from BMD to BVF, the discussion includes how to formulate them for purpose of computational modeling. An application of the conversions would be used to aid in modeling of time varying changes in vBMD as it relates to changes in BVF via bone remodeling and/or modeling.

  4. [Diagnostic value of quantitative pharmacokinetic parameters and relative quantitative pharmacokinetic parameters in breast lesions with dynamic contrast-enhanced MRI].

    PubMed

    Sun, T T; Liu, W H; Zhang, Y Q; Li, L H; Wang, R; Ye, Y Y

    2017-08-01

    Objective: To explore the differential between the value of dynamic contrast-enhanced MRI quantitative pharmacokinetic parameters and relative pharmacokinetic quantitative parameters in breast lesions. Methods: Retrospective analysis of 255 patients(262 breast lesions) who was obtained by clinical palpation , ultrasound or full-field digital mammography , and then all lessions were pathologically confirmed in Zhongda Hospital, Southeast University from May 2012 to May 2016. A 3.0 T MRI scanner was used to obtain the quantitative MR pharmacokinetic parameters: volume transfer constant (K(trans)), exchange rate constant (k(ep))and extravascular extracellular volume fraction (V(e)). And measured the quantitative pharmacokinetic parameters of normal glands tissues which on the same side of the same level of the lesions; and then calculated the value of relative pharmacokinetic parameters: rK(rans)、rk(ep) and rV(e).To explore the diagnostic value of two pharmacokinetic parameters in differential diagnosis of benign and malignant breast lesions using receiver operating curves and model of logistic regression. Results: (1)There were significant differences between benign lesions and malignant lesions in K(trans) and k(ep) ( t =15.489, 15.022, respectively, P <0.05), there were no significant differences between benign lesions and malignant lesions in V(e)( t =-2.346, P >0.05). The areas under the ROC curve(AUC)of K(trans), k(ep) and V(e) between malignant and benign lesions were 0.933, 0.948 and 0.387, the sensitivity of K(trans), k(ep) and V(e) were 77.1%, 85.0%, 51.0% , and the specificity of K(trans), k(ep) and V(e) were 96.3%, 93.6%, 60.8% for the differential diagnosis of breast lesions if taken the maximum Youden's index as cut-off. (2)There were significant differences between benign lesions and malignant lesions in rK(trans), rk(ep) and rV(e) ( t =14.177, 11.726, 2.477, respectively, P <0.05). The AUC of rK(trans), rk(ep) and rV(e) between malignant and benign

  5. Missing Value Monitoring Enhances the Robustness in Proteomics Quantitation.

    PubMed

    Matafora, Vittoria; Corno, Andrea; Ciliberto, Andrea; Bachi, Angela

    2017-04-07

    In global proteomic analysis, it is estimated that proteins span from millions to less than 100 copies per cell. The challenge of protein quantitation by classic shotgun proteomic techniques relies on the presence of missing values in peptides belonging to low-abundance proteins that lowers intraruns reproducibility affecting postdata statistical analysis. Here, we present a new analytical workflow MvM (missing value monitoring) able to recover quantitation of missing values generated by shotgun analysis. In particular, we used confident data-dependent acquisition (DDA) quantitation only for proteins measured in all the runs, while we filled the missing values with data-independent acquisition analysis using the library previously generated in DDA. We analyzed cell cycle regulated proteins, as they are low abundance proteins with highly dynamic expression levels. Indeed, we found that cell cycle related proteins are the major components of the missing values-rich proteome. Using the MvM workflow, we doubled the number of robustly quantified cell cycle related proteins, and we reduced the number of missing values achieving robust quantitation for proteins over ∼50 molecules per cell. MvM allows lower quantification variance among replicates for low abundance proteins with respect to DDA analysis, which demonstrates the potential of this novel workflow to measure low abundance, dynamically regulated proteins.

  6. Prognostic Value of Quantitative Stress Perfusion Cardiac Magnetic Resonance.

    PubMed

    Sammut, Eva C; Villa, Adriana D M; Di Giovine, Gabriella; Dancy, Luke; Bosio, Filippo; Gibbs, Thomas; Jeyabraba, Swarna; Schwenke, Susanne; Williams, Steven E; Marber, Michael; Alfakih, Khaled; Ismail, Tevfik F; Razavi, Reza; Chiribiri, Amedeo

    2018-05-01

    This study sought to evaluate the prognostic usefulness of visual and quantitative perfusion cardiac magnetic resonance (CMR) ischemic burden in an unselected group of patients and to assess the validity of consensus-based ischemic burden thresholds extrapolated from nuclear studies. There are limited data on the prognostic value of assessing myocardial ischemic burden by CMR, and there are none using quantitative perfusion analysis. Patients with suspected coronary artery disease referred for adenosine-stress perfusion CMR were included (n = 395; 70% male; age 58 ± 13 years). The primary endpoint was a composite of cardiovascular death, nonfatal myocardial infarction, aborted sudden death, and revascularization after 90 days. Perfusion scans were assessed visually and with quantitative analysis. Cross-validated Cox regression analysis and net reclassification improvement were used to assess the incremental prognostic value of visual or quantitative perfusion analysis over a baseline clinical model, initially as continuous covariates, then using accepted thresholds of ≥2 segments or ≥10% myocardium. After a median 460 days (interquartile range: 190 to 869 days) follow-up, 52 patients reached the primary endpoint. At 2 years, the addition of ischemic burden was found to increase prognostic value over a baseline model of age, sex, and late gadolinium enhancement (baseline model area under the curve [AUC]: 0.75; visual AUC: 0.84; quantitative AUC: 0.85). Dichotomized quantitative ischemic burden performed better than visual assessment (net reclassification improvement 0.043 vs. 0.003 against baseline model). This study was the first to address the prognostic benefit of quantitative analysis of perfusion CMR and to support the use of consensus-based ischemic burden thresholds by perfusion CMR for prognostic evaluation of patients with suspected coronary artery disease. Quantitative analysis provided incremental prognostic value to visual assessment and

  7. Values in Qualitative and Quantitative Research

    ERIC Educational Resources Information Center

    Duffy, Maureen; Chenail, Ronald J.

    2008-01-01

    The authors identify the philosophical underpinnings and value-ladenness of major research paradigms. They argue that useful and meaningful research findings for counseling can be generated from both qualitative and quantitative research methodologies, provided that the researcher has an appreciation of the importance of philosophical coherence in…

  8. On normality, ethnicity, and missing values in quantitative trait locus mapping

    PubMed Central

    Labbe, Aurélie; Wormald, Hanna

    2005-01-01

    Background This paper deals with the detection of significant linkage for quantitative traits using a variance components approach. Microsatellite markers were obtained for the Genetic Analysis Workshop 14 Collaborative Study on the Genetics of Alcoholism data. Ethnic heterogeneity, highly skewed quantitative measures, and a high rate of missing values are all present in this dataset and well known to impact upon linkage analysis. This makes it a good candidate for investigation. Results As expected, we observed a number of changes in LOD scores, especially for chromosomes 1, 7, and 18, along with the three factors studied. A dramatic example of such changes can be found in chromosome 7. Highly significant linkage to one of the quantitative traits became insignificant when a proper normalizing transformation of the trait was used and when analysis was carried out on an ethnically homogeneous subset of the original pedigrees. Conclusion In agreement with existing literature, transforming a trait to ensure normality using a Box-Cox transformation is highly recommended in order to avoid false-positive linkages. Furthermore, pedigrees should be sorted by ethnic groups and analyses should be carried out separately. Finally, one should be aware that the inclusion of covariates with a high rate of missing values reduces considerably the number of subjects included in the model. In such a case, the loss in power may be large. Imputation methods are then recommended. PMID:16451664

  9. Quantitative Diagnosis of Continuous-Valued, Stead-State Systems

    NASA Technical Reports Server (NTRS)

    Rouquette, N.

    1995-01-01

    Quantitative diagnosis involves numerically estimating the values of unobservable parameters that best explain the observed parameter values. We consider quantitative diagnosis for continuous, lumped- parameter, steady-state physical systems because such models are easy to construct and the diagnosis problem is considerably simpler than that for corresponding dynamic models. To further tackle the difficulties of numerically inverting a simulation model to compute a diagnosis, we propose to decompose a physical system model in terms of feedback loops. This decomposition reduces the dimension of the problem and consequently decreases the diagnosis search space. We illustrate this approach on a model of thermal control system studied in earlier research.

  10. Carr-Purcell-Meiboom-Gill imaging of prostate cancer: quantitative T2 values for cancer discrimination.

    PubMed

    Roebuck, Joseph R; Haker, Steven J; Mitsouras, Dimitris; Rybicki, Frank J; Tempany, Clare M; Mulkern, Robert V

    2009-05-01

    Quantitative, apparent T(2) values of suspected prostate cancer and healthy peripheral zone tissue in men with prostate cancer were measured using a Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence in order to assess the cancer discrimination potential of tissue T(2) values. The CPMG imaging sequence was used to image the prostates of 18 men with biopsy-proven prostate cancer. Whole gland coverage with nominal voxel volumes of 0.54 x 1.1 x 4 mm(3) was obtained in 10.7 min, resulting in data sets suitable for generating high-quality images with variable T(2)-weighting and for evaluating quantitative T(2) values on a pixel-by-pixel basis. Region-of-interest analysis of suspected healthy peripheral zone tissue and suspected cancer, identified on the basis of both T(1)- and T(2)-weighted signal intensities and available histopathology reports, yielded significantly (P<.0001) longer apparent T(2) values in suspected healthy tissue (193+/-49 ms) vs. suspected cancer (100+/-26 ms), suggesting potential utility of this method as a tissue specific discrimination index for prostate cancer. We conclude that CPMG imaging of the prostate can be performed in reasonable scan times and can provide advantages over T(2)-weighted fast spin echo (FSE) imaging alone, including quantitative T(2) values for cancer discrimination as well as proton density maps without the point spread function degradation associated with short effective echo time FSE sequences.

  11. Magnetic Resonance Imaging of Intracranial Hypotension: Diagnostic Value of Combined Qualitative Signs and Quantitative Metrics.

    PubMed

    Aslan, Kerim; Gunbey, Hediye Pinar; Tomak, Leman; Ozmen, Zafer; Incesu, Lutfi

    The aim of this study was to investigate whether the use of combination quantitative metrics (mamillopontine distance [MPD], pontomesencephalic angle, and mesencephalon anterior-posterior/medial-lateral diameter ratios) with qualitative signs (dural enhancement, subdural collections/hematoma, venous engorgement, pituitary gland enlargements, and tonsillar herniations) provides a more accurate diagnosis of intracranial hypotension (IH). The quantitative metrics and qualitative signs of 34 patients and 34 control subjects were assessed by 2 independent observers. Receiver operating characteristic (ROC) curve was used to evaluate the diagnostic performance of quantitative metrics and qualitative signs, and for the diagnosis of IH, optimum cutoff values of quantitative metrics were found with ROC analysis. Combined ROC curve was measured for the quantitative metrics, and qualitative signs combinations in determining diagnostic accuracy and sensitivity, specificity, and positive and negative predictive values were found, and the best model combination was formed. Whereas MPD and pontomesencephalic angle were significantly lower in patients with IH when compared with the control group (P < 0.001), mesencephalon anterior-posterior/medial-lateral diameter ratio was significantly higher (P < 0.001). For qualitative signs, the highest individual distinctive power was dural enhancement with area under the ROC curve (AUC) of 0.838. For quantitative metrics, the highest individual distinctive power was MPD with AUC of 0.947. The best accuracy in the diagnosis of IH was obtained by combination of dural enhancement, venous engorgement, and MPD with an AUC of 1.00. This study showed that the combined use of dural enhancement, venous engorgement, and MPD had diagnostic accuracy of 100 % for the diagnosis of IH. Therefore, a more accurate IH diagnosis can be provided with combination of quantitative metrics with qualitative signs.

  12. Carr-Purcell-Meiboom-Gill (CPMG) Imaging of Prostate Cancer: Quantitative T2 Values for Cancer Discrimination

    PubMed Central

    Roebuck, Joseph R.; Haker, Steven J.; Mitsouras, Dimitris; Rybicki, Frank J.; Tempany, Clare M.; Mulkern, Robert V.

    2009-01-01

    Quantitative, apparent T2 values of suspected prostate cancer and healthy peripheral zone tissue in men with prostate cancer were measured using a Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence in order to assess the cancer discrimination potential of tissue T2 values. The CPMG imaging sequence was used to image the prostates of 18 men with biopsy proven prostate cancer. Whole gland coverage with nominal voxel volumes of 0.54 × 1.1 × 4 mm3 was obtained in 10.7 minutes, resulting in data sets suitable for generating high quality images with variable T2-weighting and for evaluating quantitative T2 values on a pixel-by-pixel basis. Region-of-interest analysis of suspected healthy peripheral zone tissue and suspected cancer, identified on the basis of both T1- and T2-weighted signal intensities and available histopathology reports, yielded significantly (p < 0.0001) longer apparent T2 values in suspected healthy tissue (193 ± 49 ms) vs. suspected cancer (100 ± 26 ms), suggesting potential utility of this method as a tissue specific discrimination index for prostate cancer. We conclude that CPMG imaging of the prostate can be performed in reasonable scan times and can provide advantages over T2-weighted fast spin echo imaging alone, including quantitative T2 values for cancer discrimination as well as proton density maps without the point spread function degradation associated with short effective echo time fast spin echo (FSE) sequences. PMID:18823731

  13. Association between quantitative measures obtained using fluorescence-based methods and activity status of occlusal caries lesions in primary molars.

    PubMed

    Novaes, Tatiane Fernandes; Reyes, Alessandra; Matos, Ronilza; Antunes-Pontes, Laura Regina; Marques, Renata Pereira de Samuel; Braga, Mariana Minatel; Diniz, Michele Baffi; Mendes, Fausto Medeiros

    2017-05-01

    Fluorescence-based methods (FBM) can add objectiveness to diagnosis strategy for caries. Few studies, however, have focused on the evaluation of caries activity. To evaluate the association between quantitative measures obtained with FBM, clinical parameters acquired from the patients, caries detection, and assessment of activity status in occlusal surfaces of primary molars. Six hundred and six teeth from 113 children (4-14 years) were evaluated. The presence of a biofilm, caries experience, and the number of active lesions were recorded. The teeth were assessed using FBM: DIAGNOdent pen (Lfpen) and Quantitative light-induced fluorescence (QLF). As reference standard, all teeth were evaluated using the ICDAS (International Caries Detection and Assessment System) associated with clinical activity assessments. Multilevel regressions compared the FBM values and evaluated the association between the FBM measures and clinical variables related to the caries activity. The measures from the FBM were higher in cavitated lesions. Only, ∆F values distinguished active and inactive lesions. The LFpen measures were higher in active lesions, at the cavitated threshold (56.95 ± 29.60). Following regression analyses, only the presence of visible biofilm on occlusal surfaces (adjusted prevalence ratio = 1.43) and ∆R values of the teeth (adjusted prevalence ratio = 1.02) were associated with caries activity. Some quantitative measures from FBM parameters are associated with caries activity evaluation, which is similar to the clinical evaluation of the presence of visible biofilm. © 2016 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Quantitative values of blood flow through the human forearm, hand, and finger as functions of temperature

    NASA Technical Reports Server (NTRS)

    Montgomery, L. D.

    1974-01-01

    A literature search was made to obtain values of human forearm, hand and finger blood flow as functions of environmental temperature. The sources used include both government and laboratory reports and the research presented in the open literature. An attempt was made to review many of the more quantitative noninvasive determinations and to collate the results in such a way as to yield blood flow values for each body segment as continuous functions of temperature. A brief review of the various ways used to measure blood flow is included along with an abstract of each work from which data was taken.

  15. Influence of echo time in quantitative proton MR spectroscopy using LCModel.

    PubMed

    Yamamoto, Tetsuya; Isobe, Tomonori; Akutsu, Hiroyoshi; Masumoto, Tomohiko; Ando, Hiroki; Sato, Eisuke; Takada, Kenta; Anno, Izumi; Matsumura, Akira

    2015-06-01

    The objective of this study was to elucidate the influence on quantitative analysis using LCModel with the condition of echo time (TE) longer than the recommended values in the spectrum acquisition specifications. A 3T magnetic resonance system was used to perform proton magnetic resonance spectroscopy. The participants were 5 healthy volunteers and 11 patients with glioma. Data were collected at TE of 72, 144 and 288ms. LCModel was used to quantify several metabolites (N-acetylaspartate, creatine and phosphocreatine, and choline-containing compounds). The results were compared with quantitative values obtained by using the T2-corrected internal reference method. In healthy volunteers, when TE was long, the quantitative values obtained using LCModel were up to 6.8-fold larger (p<0.05) than those obtained using the T2-corrected internal reference method. The ratios of the quantitative values obtained by the two methods differed between metabolites (p<0.05). In patients with glioma, the ratios of quantitative values obtained by the two methods tended to be larger at longer TE, similarly to the case of healthy volunteers, and large between-individual variation in the ratios was observed. In clinical practice, TE is sometimes set longer than the value recommended for LCModel. If TE is long, LCModel overestimates the quantitative value since it cannot compensate for signal attenuation, and this effect is different for each metabolite and condition. Therefore, if TE is longer than recommended, it is necessary to account for the possibly reduced reliability of quantitative values calculated using LCModel. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Obtaining high g-values with low degree expansion of the phasefunction

    NASA Astrophysics Data System (ADS)

    Rinzema, Kees; ten Bosch, Jaap J.; Ferwerda, Hedzer A.; Hoenders, Bernhard J.

    1994-02-01

    Analytic theory of anisotropic random flight requires the expansion of phase-functions in spherical harmonics. The number of terms should be limited while a g value should be obtained that is as high as possible. We describe how such a phase function can be constructed for a given number N of spherical components of the phasefunction, while obtaining a maximum value of the asymmetry parameter g.

  17. Utility of DWI with quantitative ADC values in ovarian tumors: a meta-analysis of diagnostic test performance.

    PubMed

    Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui

    2018-01-01

    Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.

  18. [Value of mDIXON-Quant sequence, diffusion-weighted imaging in quantitatively diagnosing the sacroiliitis stages].

    PubMed

    An, Y Y; Li, H X; Zhan, Y; Lei, X W

    2017-10-10

    Objective: To evaluate the value of mDIXON-Quant sequence, diffusion-weighted imaging (DWI) in quantitative diagnosing of the sacroiliitis stages in patients with ankylosing spondylitis (AS). Methods: Based on the Bath Ankylosing Spondylitis Activity Index (BASDAI) and laboratory parameters, a total of 51 patients were diagnosed with AS. They were divided into two groups as early active group ( n =20) and chronic active group ( n =31), and at the same time, 25 healthy people from Tianjin were included as control group. The regular MRI sequences and mDIXON-Quant sequence, DWI were obtained. The apparent diffusion coefficient (ADC) and fat-signal fraction (FF) value of bone marrow with edema of the sacroiliac joints in early active group and chronic active group and of subchondral bone marrow of sacroiliac joint in control group all were measured by ADC maps and FF maps. Mean (FF, ADC) values were compared between groups. Results: The ADC value of the early active group, chronic active group and the control group is (1.07±0.20)×10(-3)mm(2)/s, (1.00±0.22)×10(-3)mm(2)/s, (0.25±0.07)×10(-3)mm(2)/s, respectively, and the differences of ADC value between early active group and control group, chronic active group and control group were significant ( P <0.01), but the difference of the ADC value between early active group and chronic active group was not significant ( P =0.394). That is to say, the ADC value can't distinguish the early active group and chronic active group. The differences of FF value between groups was significant ( P <0.01), and the FF value of bone marrow with edema in chronic active group were higher than that in early active group. Conclusions: The mDIXON-Quant sequence can quantitatively diagnose early active group and chronic active group, and the diagnostic value is better than DWI. Thus, it can provide guidance for clinical treatment and prognosis.

  19. Legionella in water samples: how can you interpret the results obtained by quantitative PCR?

    PubMed

    Ditommaso, Savina; Ricciardi, Elisa; Giacomuzzi, Monica; Arauco Rivera, Susan R; Zotti, Carla M

    2015-02-01

    Evaluation of the potential risk associated with Legionella has traditionally been determined from culture-based methods. Quantitative polymerase chain reaction (qPCR) is an alternative tool that offers rapid, sensitive and specific detection of Legionella in environmental water samples. In this study we compare the results obtained by conventional qPCR (iQ-Check™ Quanti Legionella spp.; Bio-Rad) and by culture method on artificial samples prepared in Page's saline by addiction of Legionella pneumophila serogroup 1 (ATCC 33152) and we analyse the selective quantification of viable Legionella cells by the qPCR-PMA method. The amount of Legionella DNA (GU) determined by qPCR was 28-fold higher than the load detected by culture (CFU). Applying the qPCR combined with PMA treatment we obtained a reduction of 98.5% of the qPCR signal from dead cells. We observed a dissimilarity in the ability of PMA to suppress the PCR signal in samples with different amounts of bacteria: the effective elimination of detection signals by PMA depended on the concentration of GU and increasing amounts of cells resulted in higher values of reduction. Using the results from this study we created an algorithm to facilitate the interpretation of viable cell level estimation with qPCR-PMA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. A new look on anomalous thermal gradient values obtained in South Portugal

    NASA Astrophysics Data System (ADS)

    Duque, M. R.; Malico, I.

    2012-04-01

    A NEW LOOK ON THE ANOMALOUS THERMAL GRADIENT VALUES OBTAINED IN SOUTH PORTUGAL Duque, M. R. and Malico, I. M. Physics Department, University of Évora, Rua Romão Ramalho, 59,7000-671, Évora, Portugal It is well known that soil temperatures can be altered by water circulation. In this paper, we study numerically this effect by simulating some aquifers occurring in South Portugal. At this location, the thermal gradient values obtained in boreholes with depths less than 200 m, range between 22 and 30 °C km-1. However, there, it is easy to find places where temperatures are around 30 °C, at depths of 100 m. The obtained thermal gradient values show an increase one day after raining and a decrease during the dry season. Additionally, the curve of temperature as function of depth showed no hot water inlet in the hole. The region studied shows a smooth topography due to intensive erosion, but it was affected by alpine and hercinian orogenies. As a result, a high topography in depth, with folds and wrinkles is present. The space between adjacent folds is now filled by small sedimentary basins. Aquifers existing in this region can reach considerable depths and return to depths near the surface, but hot springs in the area are scarce. Water temperature rises in depth, and when the speed is high enough high temperatures near the surface, due to water circulation, can be found. The ability of the fluid to flow through the system depends on topography relief, rock permeability and basal heat flow. In this study, the steady-state fluid flow and heat transfer by conduction and advection are modeled. Fractures in the medium are simulated by an equivalent porous medium saturated with liquid. Thermal conductivity values for the water and the rocks can vary in space .Porosities used have high values in the region of the aquifer, low values in the lower region of the model and intermediate values in the upper regions. The results obtained show that temperature anomaly values

  1. Total sperm per ejaculate of men: obtaining a meaningful value or a mean value with appropriate precision.

    PubMed

    Amann, Rupert P; Chapman, Phillip L

    2009-01-01

    We retrospectively mined and modeled data to answer 3 questions. 1) Relative to an estimate based on approximately 20 semen samples, how imprecise is an estimate of an individual's total sperm per ejaculate (TSperm) based on 1 sample? 2) What is the impact of abstinence interval on TSperm and TSperm/h? 3) How many samples are needed to provide a meaningful estimate of an individual's mean TSperm or TSperm/h? Data were for 18-20 consecutive masturbation samples from each of 48 semen donors. Modeling exploited the gamma distribution of values for TSperm and a unique approach to project to future samples. Answers: 1) Within-individual coefficients of variation were similar for TSperm or TSperm/h abstinence and ranged from 17% to 51%; average approximately 34%. TSperm or TSperm/h in any individual sample from a given donor was between -20% and +20% of the mean value in 48% of 18-20 samples per individual. 2) For a majority of individuals, TSperm increased in a nearly linear manner through approximately 72 hours of abstinence. TSperm and TSperm/h after 18-36 hours' abstinence are high. To obtain meaningful values for diagnostic purposes and maximize distinction of individuals with relatively low or high sperm production, the requested abstinence should be 42-54 hours with an upper limit of 64 hours. For individuals producing few sperm, 7 days or more of abstinence might be appropriate to obtain sperm for insemination. 3) At least 3 samples from a hypothetical future subject are recommended for most applications. Assuming 60 hours' abstinence, 80% confidence limits for TSperm/h for 1, 3, or 6 samples would be 70%-163%, 80%-130%, or 85%-120% of the mean for observed values. In only approximately 50% of cases would TSperm/h for a single sample be within -16% and +30% of the true mean value for that subject. Pooling values for TSperm in samples obtained after 18-36 or 72-168 hours' abstinence with values for TSperm obtained after 42-64 hours is inappropriate. Reliance on

  2. Faculty Grading of Quantitative Problems: A Mismatch between Values and Practice

    ERIC Educational Resources Information Center

    Petcovic, Heather L.; Fynewever, Herb; Henderson, Charles; Mutambuki, Jacinta M.; Barney, Jeffrey A.

    2013-01-01

    Grading practices can send a powerful message to students about course expectations. A study by Henderson et al. ("American Journal of Physics" 72:164-169, 2004) in physics education has identified a misalignment between what college instructors say they value and their actual scoring of quantitative student solutions. This work identified three…

  3. Normal Values of Tissue-Muscle Perfusion Indexes of Lower Limbs Obtained with a Scintigraphic Method.

    PubMed

    Manevska, Nevena; Stojanoski, Sinisa; Pop Gjorceva, Daniela; Todorovska, Lidija; Miladinova, Daniela; Zafirova, Beti

    2017-09-01

    Introduction Muscle perfusion is a physiologic process that can undergo quantitative assessment and thus define the range of normal values of perfusion indexes and perfusion reserve. The investigation of the microcirculation has a crucial role in determining the muscle perfusion. Materials and method The study included 30 examinees, 24-74 years of age, without a history of confirmed peripheral artery disease and all had normal findings on Doppler ultrasonography and pedo-brachial index of lower extremity (PBI). 99mTc-MIBI tissue muscle perfusion scintigraphy of lower limbs evaluates tissue perfusion in resting condition "rest study" and after workload "stress study", through quantitative parameters: Inter-extremity index (for both studies), left thigh/right thigh (LT/RT) left calf/right calf (LC/RC) and perfusion reserve (PR) for both thighs and calves. Results In our investigated group we assessed the normal values of quantitative parameters of perfusion indexes. Indexes ranged for LT/RT in rest study 0.91-1.05, in stress study 0.92-1.04. LC/RC in rest 0.93-1.07 and in stress study 0.93-1.09. The examinees older than 50 years had insignificantly lower perfusion reserve of these parameters compared with those younger than 50, LC (p=0.98), and RC (p=0.6). Conclusion This non-invasive scintigraphic method allows in individuals without peripheral artery disease to determine the range of normal values of muscle perfusion at rest and stress condition and to clinically implement them in evaluation of patients with peripheral artery disease for differentiating patients with normal from those with impaired lower limbs circulation.

  4. Quantitative X-ray mapping, scatter diagrams and the generation of correction maps to obtain more information about your material

    NASA Astrophysics Data System (ADS)

    Wuhrer, R.; Moran, K.

    2014-03-01

    Quantitative X-ray mapping with silicon drift detectors and multi-EDS detector systems have become an invaluable analysis technique and one of the most useful methods of X-ray microanalysis today. The time to perform an X-ray map has reduced considerably with the ability to map minor and trace elements very accurately due to the larger detector area and higher count rate detectors. Live X-ray imaging can now be performed with a significant amount of data collected in a matter of minutes. A great deal of information can be obtained from X-ray maps. This includes; elemental relationship or scatter diagram creation, elemental ratio mapping, chemical phase mapping (CPM) and quantitative X-ray maps. In obtaining quantitative x-ray maps, we are able to easily generate atomic number (Z), absorption (A), fluorescence (F), theoretical back scatter coefficient (η), and quantitative total maps from each pixel in the image. This allows us to generate an image corresponding to each factor (for each element present). These images allow the user to predict and verify where they are likely to have problems in our images, and are especially helpful to look at possible interface artefacts. The post-processing techniques to improve the quantitation of X-ray map data and the development of post processing techniques for improved characterisation are covered in this paper.

  5. Conditional Toxicity Value (CTV) Predictor: An In Silico Approach for Generating Quantitative Risk Estimates for Chemicals.

    PubMed

    Wignall, Jessica A; Muratov, Eugene; Sedykh, Alexander; Guyton, Kathryn Z; Tropsha, Alexander; Rusyn, Ivan; Chiu, Weihsueh A

    2018-05-01

    Human health assessments synthesize human, animal, and mechanistic data to produce toxicity values that are key inputs to risk-based decision making. Traditional assessments are data-, time-, and resource-intensive, and they cannot be developed for most environmental chemicals owing to a lack of appropriate data. As recommended by the National Research Council, we propose a solution for predicting toxicity values for data-poor chemicals through development of quantitative structure-activity relationship (QSAR) models. We used a comprehensive database of chemicals with existing regulatory toxicity values from U.S. federal and state agencies to develop quantitative QSAR models. We compared QSAR-based model predictions to those based on high-throughput screening (HTS) assays. QSAR models for noncancer threshold-based values and cancer slope factors had cross-validation-based Q 2 of 0.25-0.45, mean model errors of 0.70-1.11 log 10 units, and applicability domains covering >80% of environmental chemicals. Toxicity values predicted from QSAR models developed in this study were more accurate and precise than those based on HTS assays or mean-based predictions. A publicly accessible web interface to make predictions for any chemical of interest is available at http://toxvalue.org. An in silico tool that can predict toxicity values with an uncertainty of an order of magnitude or less can be used to quickly and quantitatively assess risks of environmental chemicals when traditional toxicity data or human health assessments are unavailable. This tool can fill a critical gap in the risk assessment and management of data-poor chemicals. https://doi.org/10.1289/EHP2998.

  6. Quantitative Comparison of Tandem Mass Spectra Obtained on Various Instruments

    NASA Astrophysics Data System (ADS)

    Bazsó, Fanni Laura; Ozohanics, Oliver; Schlosser, Gitta; Ludányi, Krisztina; Vékey, Károly; Drahos, László

    2016-08-01

    The similarity between two tandem mass spectra, which were measured on different instruments, was compared quantitatively using the similarity index (SI), defined as the dot product of the square root of peak intensities in the respective spectra. This function was found to be useful for comparing energy-dependent tandem mass spectra obtained on various instruments. Spectral comparisons show the similarity index in a 2D "heat map", indicating which collision energy combinations result in similar spectra, and how good this agreement is. The results and methodology can be used in the pharma industry to design experiments and equipment well suited for good reproducibility. We suggest that to get good long-term reproducibility, it is best to adjust the collision energy to yield a spectrum very similar to a reference spectrum. It is likely to yield better results than using the same tuning file, which, for example, does not take into account that contamination of the ion source due to extended use may influence instrument tuning. The methodology may be used to characterize energy dependence on various instrument types, to optimize instrumentation, and to study the influence or correlation between various experimental parameters.

  7. Using Neutron Spectroscopy to Obtain Quantitative Composition Data of Ganymede's Surface from the Jupiter Ganymede Orbiter

    NASA Astrophysics Data System (ADS)

    Lawrence, D. J.; Maurice, S.; Patterson, G. W.; Hibbitts, C. A.

    2010-05-01

    Understanding the global composition of Ganymede's surface is a key goal of the Europa Jupiter System Mission (EJSM) that is being jointly planned by NASA and ESA. Current plans for obtaining surface information with the Jupiter Ganymede Orbiter (JGO) use spectral imaging measurements. While spectral imaging can provide good mineralogy-related information, quantitative data about elemental abundances can often be hindered by non-composition variations due to surface effects (e.g., space weathering, grain effects, temperature, etc.). Orbital neutron and gamma-ray spectroscopy can provide quantitative composition information that is complementary to spectral imaging measurements, as has been demonstrated with similar instrumental combinations at the Moon, Mars, and Mercury. Neutron and gamma-ray measurements have successfully returned abundance information in a hydrogen-rich environment on Mars. In regards to neutrons and gamma-rays, there are many similarities between the Mars and Ganymede hydrogen-rich environments. In this study, we present results of neutron transport models, which show that quantitative composition information from Ganymede's surface can be obtained in a realistic mission scenario. Thermal and epithermal neutrons are jointly sensitive to the abundances of hydrogen and neutron absorbing elements, such as iron and titanium. These neutron measurements can discriminate between regions that are rich or depleted in neutron absorbing elements, even in the presence of large amounts of hydrogen. Details will be presented about how the neutron composition parameters can be used to meet high-level JGO science objectives, as well as an overview of a neutron spectrometer than can meet various mission and stringent environmental requirements.

  8. Lossless and lossy compression of quantitative phase images of red blood cells obtained by digital holographic imaging.

    PubMed

    Jaferzadeh, Keyvan; Gholami, Samaneh; Moon, Inkyu

    2016-12-20

    In this paper, we evaluate lossless and lossy compression techniques to compress quantitative phase images of red blood cells (RBCs) obtained by an off-axis digital holographic microscopy (DHM). The RBC phase images are numerically reconstructed from their digital holograms and are stored in 16-bit unsigned integer format. In the case of lossless compression, predictive coding of JPEG lossless (JPEG-LS), JPEG2000, and JP3D are evaluated, and compression ratio (CR) and complexity (compression time) are compared against each other. It turns out that JP2k can outperform other methods by having the best CR. In the lossy case, JP2k and JP3D with different CRs are examined. Because some data is lost in a lossy way, the degradation level is measured by comparing different morphological and biochemical parameters of RBC before and after compression. Morphological parameters are volume, surface area, RBC diameter, sphericity index, and the biochemical cell parameter is mean corpuscular hemoglobin (MCH). Experimental results show that JP2k outperforms JP3D not only in terms of mean square error (MSE) when CR increases, but also in compression time in the lossy compression way. In addition, our compression results with both algorithms demonstrate that with high CR values the three-dimensional profile of RBC can be preserved and morphological and biochemical parameters can still be within the range of reported values.

  9. Quantitative TLC-Image Analysis of Urinary Creatinine Using Iodine Staining and RGB Values.

    PubMed

    Kerr, Emily; West, Caroline; Kradtap Hartwell, Supaporn

    2016-04-01

    Digital image analysis of the separation results of colorless analytes on thin-layer chromatography (TLC) plates usually involves using specially tailored software to analyze the images generated from either a UV scanner or UV lamp station with a digital camera or a densitometer. Here, a low-cost alternative setup for quantitative TLC-digital image analysis is demonstrated using a universal staining reagent (iodine vapor), an office scanner and a commonly available software (Microsoft Paint) for analysis of red, green and blue colors (RGB values). Urinary creatinine is used as a model analyte to represent a sample in complicated biological matrices. Separation was carried out on a silica gel plate using a butanol-NH4OH-H2O (40 : 10 : 50, v/v) mobile phase with a 6-cm solvent front. It is important that the TLC plate be stained evenly and with sufficient staining time. Staining the TLC plate in a 23.4 × 18.8 × 6.8 cm chamber containing about 70 g iodine crystals yielded comparable results for the staining times of 30-60 min. The Green value offered the best results in the linear working range (0.0810-0.9260 mg/mL) and precision (2.03% RSD, n = 10). The detection limit was found to be 0.24 µg per 3 µL spot. Urinary creatinine concentrations determined by TLC-digital image analysis using the green value calibration graph agree well with results obtained from high-pressure liquid chromatography (HPLC). © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Diagnostic value of quantitative assessment of cardiac 18F-fluoro-2-deoxyglucose uptake in suspected cardiac sarcoidosis.

    PubMed

    Lebasnier, Adrien; Legallois, Damien; Bienvenu, Boris; Bergot, Emmanuel; Desmonts, Cédric; Zalcman, Gérard; Agostini, Denis; Manrique, Alain

    2018-06-01

    The identification of cardiac sarcoidosis is challenging as there is no gold standard consensually admitted for its diagnosis. The aim of this study was to evaluate the diagnostic value of the assessment of cardiac dynamic 18 F-fluoro-2-deoxyglucose positron emission tomography ( 18 F-FDG PET/CT) and net influx constant (Ki) in patients suspected of cardiac sarcoidosis. Data obtained from 30 biopsy-proven sarcoidosis patients suspected of cardiac sarcoidosis who underwent a 50-min list-mode cardiac dynamic 18 F-FDG PET/CT after a 24 h high-fat and low-carbohydrate diet were analyzed. A normalized coefficient of variation of quantitative glucose influx constant, calculated as the ratio: standard deviation of the segmental Ki (min -1 )/global Ki (min -1 ) was determined using a validated software (Carimas ® 2.4, Turku PET Centre). Cardiac sarcoidosis was diagnosed according to the Japanese Ministry of Health and Welfare criteria. Receiving operating curve analysis was performed to determine sensitivity and specificity of cardiac dynamic 18 F-FDG PET/CT analysis to diagnose cardiac sarcoidosis. Six out of 30 patients (20%) were diagnosed as having cardiac sarcoidosis. Myocardial glucose metabolism was significantly heterogeneous in patients with cardiac sarcoidosis who showed significantly higher normalized coefficient of variation values compared to patients without cardiac sarcoidosis (0.513 ± 0.175 vs. 0.205 ± 0.081; p = 0.0007). Using ROC curve analysis, we found a cut-off value of 0.38 for the diagnosis of cardiac sarcoidosis with a sensitivity of 100% and a specificity of 91%. Our results suggest that quantitative analysis of cardiac dynamic 18 F-FDG PET/CT could be a useful tool for the diagnosis of cardiac sarcoidosis.

  11. Faculty Grading of Quantitative Problems: A Mismatch between Values and Practice

    NASA Astrophysics Data System (ADS)

    Petcovic, Heather L.; Fynewever, Herb; Henderson, Charles; Mutambuki, Jacinta M.; Barney, Jeffrey A.

    2013-04-01

    Grading practices can send a powerful message to students about course expectations. A study by Henderson et al. (American Journal of Physics 72:164-169, 2004) in physics education has identified a misalignment between what college instructors say they value and their actual scoring of quantitative student solutions. This work identified three values that guide grading decisions: (1) a desire to see students' reasoning, (2) a readiness to deduct points from solutions with obvious errors and a reluctance to deduct points from solutions that might be correct, and (3) a tendency to assume correct reasoning when solutions are ambiguous. These authors propose that when values are in conflict, the conflict is resolved by placing the burden of proof on either the instructor or the student. Here, we extend the results of the physics study to earth science ( n = 7) and chemistry ( n = 10) instructors in a think-aloud interview study. Our results suggest that both the previously identified three values and the misalignment between values and grading practices exist among science faculty more generally. Furthermore, we identified a fourth value not previously recognized. Although all of the faculty across both studies stated that they valued seeing student reasoning, the combined effect suggests that only 49% of faculty across the three disciplines graded work in such a way that would actually encourage students to show their reasoning, and 34% of instructors could be viewed as penalizing students for showing their work. This research may contribute toward a better alignment between values and practice in faculty development.

  12. A gold nanoparticle-based semi-quantitative and quantitative ultrasensitive paper sensor for the detection of twenty mycotoxins

    NASA Astrophysics Data System (ADS)

    Kong, Dezhao; Liu, Liqiang; Song, Shanshan; Suryoprabowo, Steven; Li, Aike; Kuang, Hua; Wang, Libing; Xu, Chuanlai

    2016-02-01

    A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan reader, with the calculated limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.04-0.17, 0.06-49, 0.15-0.22, 0.056-0.49 and 0.53-1.05 μg kg-1, respectively. The analytical results of spiked samples were in accordance with the accurate content in the simultaneous detection analysis. This newly developed ICA strip assay is suitable for the on-site detection and rapid initial screening of mycotoxins in cereal samples, facilitating both semi-quantitative and quantitative determination.A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan

  13. Assessment of the value of quantitative thyroid scintigraphy for determination of thyroid function in dogs.

    PubMed

    Shiel, R E; Pinilla, M; McAllister, H; Mooney, C T

    2012-05-01

    To assess the value of thyroid scintigraphy to determine thyroid status in dogs with hypothyroidism and various non-thyroidal illnesses. Thyroid hormone concentrations were measured and quantitative thyroid scintigraphy performed in 21 dogs with clinical and/or clinicopathological features consistent with hypothyroidism. In 14 dogs with technetium thyroidal uptake values consistent with euthyroidism, further investigations supported non-thyroidal illness. In five dogs with technetium thyroidal uptake values within the hypothyroid range, primary hypothyroidism was confirmed as the only disease in four. The remaining dog had pituitary-dependent hyperadrenocorticism. Two dogs had technetium thyroidal uptake values in the non-diagnostic range. One dog had iodothyronine concentrations indicative of euthyroidism. In the other, a dog receiving glucocorticoid therapy, all iodothyronine concentrations were decreased. Markedly asymmetric technetium thyroidal uptake was present in two dogs. All iodothyronine concentrations were within reference interval but canine thyroid stimulating hormone concentration was elevated in one. Non-thyroidal illness was identified in both cases. In dogs, technetium thyroidal uptake is a useful test to determine thyroid function. However, values may be non-diagnostic, asymmetric uptake can occur and excess glucocorticoids may variably suppress technetium thyroidal uptake and/or thyroid hormone concentrations. Further studies are necessary to evaluate quantitative thyroid scintigraphy as a gold standard method for determining canine thyroid function. © 2012 British Small Animal Veterinary Association.

  14. Feasibility of Obtaining Quantitative 3-Dimensional Information Using Conventional Endoscope: A Pilot Study

    PubMed Central

    Hyun, Jong Jin; Keum, Bora; Seo, Yeon Seok; Kim, Yong Sik; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang; Lim, Jong-Wook; Woo, Dong-Gi; Kim, Young-Joong; Lim, Myo-Taeg

    2012-01-01

    Background/Aims Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information. Methods Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model. Results The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model. Conclusions It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object. PMID:22977798

  15. Relationship Between Ebola Virus Real-Time Quantitative Polymerase Chain Reaction-Based Threshold Cycle Value and Virus Isolation From Human Plasma.

    PubMed

    Spengler, Jessica R; McElroy, Anita K; Harmon, Jessica R; Ströher, Ute; Nichol, Stuart T; Spiropoulou, Christina F

    2015-10-01

    We performed a longitudinal analysis of plasma samples obtained from 4 patients with Ebola virus (EBOV) disease (EVD) to determine the relationship between the real-time quantitative reverse transcriptase polymerase chain reaction (qRT-PCR)-based threshold cycle (Ct) value and the presence of infectious EBOV. EBOV was not isolated from plasma samples with a Ct value of >35.5 or >12 days after onset of symptoms. EBOV was not isolated from plasma samples in which anti-EBOV nucleoprotein immunoglobulin G was detected. These data demonstrate the utility of interpreting qRT-PCR results in the context of the course of EBOV infection and associated serological responses for patient-management decisions. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  16. Quantitative cultures of bronchoscopically obtained specimens should be performed for optimal management of ventilator-associated pneumonia.

    PubMed

    Baselski, Vickie; Klutts, J Stacey; Baselski, Vickie; Klutts, J Stacey

    2013-03-01

    Ventilator-associated pneumonia (VAP) is a leading cause of health care-associated infection. It has a high rate of attributed mortality, and this mortality is increased in patients who do not receive appropriate empirical antimicrobial therapy. As a result of the overuse of broad-spectrum antimicrobials such as the carbapenems, strains of Acinetobacter, Enterobacteriaceae, and Pseudomonas aeruginosa susceptible only to polymyxins and tigecycline have emerged as important causes of VAP. The need to accurately diagnose VAP so that appropriate discontinuation or de-escalation of antimicrobial therapy can be initiated to reduce this antimicrobial pressure is essential. Practice guidelines for the diagnosis of VAP advocate the use of bronchoalveolar lavage (BAL) fluid obtained either bronchoscopically or by the use of a catheter passed through the endotracheal tube. The CDC recommends that quantitative cultures be performed on these specimens, using ≥ 10(4) CFU/ml to designate a positive culture (http://www.cdc.gov/nhsn/TOC_PSCManual.html, accessed 30 October 2012). However, there is no consensus in the clinical microbiology community as to whether these specimens should be cultured quantitatively, using the aforementioned designated bacterial cell count to designate infection, or by a semiquantitative approach. We have asked Vickie Baselski, University of Tennessee Health Science Center, who was the lead author on one of the seminal papers on quantitative BAL fluid culture, to explain why she believes that quantitative BAL fluid cultures are the optimal strategy for VAP diagnosis. We have Stacey Klutts, University of Iowa, to advocate the semiquantitative approach.

  17. The value of quantitative shear wave elastography in differentiating the cervical lymph nodes in patients with thyroid nodules.

    PubMed

    You, Jun; Chen, Juan; Xiang, Feixiang; Song, Yue; Khamis, Simai; Lu, Chengfa; Lv, Qing; Zhang, Yanrong; Xie, Mingxing

    2018-04-01

    This study aimed at evaluating the diagnostic performance of quantitative shear wave elastography (SWE) in differentiating metastatic cervical lymph nodes from benign nodes in patients with thyroid nodules. One hundred and forty-one cervical lymph nodes from 39 patients with thyroid nodules that were diagnosed as papillary thyroid cancer had been imaged with SWE. The shear elasticity modulus, which indicates the stiffness of the lymph nodes, was measured in terms of maximum shear elasticity modulus (maxSM), minimum shear elasticity modulus (minSM), mean shear elasticity modulus (meanSM), and standard deviation (SD) of the shear elasticity modulus. All the patients underwent thyroid surgery, 50 of the suspicious lymph nodes were resected, and 91 lymph nodes were followed up for 6 months. The maxSM value, minSM value, meanSM value, and SD value of the metastatic lymph nodes were significantly higher than those of the benign nodes. The area under the curve of the maxSM value, minSM value, meanSM value, and SD value were 0.918, 0.606, 0.865, and 0.915, respectively. SWE can differentiate metastasis from benign cervical lymph nodes in patients with thyroid nodules, and the maxSM, meanSM, and SD may be valuable quantitative indicators for characterizing cervical lymph nodes.

  18. Added value of semi-quantitative breast-specific gamma imaging in the work-up of suspicious breast lesions compared to mammography, ultrasound and 3-T MRI

    PubMed Central

    Seymer, A; Keinrath, P; Holzmannhofer, J; Pirich, C; Hergan, K; Meissnitzer, M W

    2015-01-01

    Objective: To prospectively analyse the diagnostic value of semi-quantitative breast-specific gamma imaging (BSGI) in the work-up of suspicious breast lesions compared with that of mammography (MG), breast ultrasound and MRI of the breast. Methods: Within a 15-month period, 67 patients with 92 breast lesions rated as Category IV or V according to the breast imaging reporting and data system detected with MG and/or ultrasound were included into the study. After the injection of 740–1110 MBq of Technetium-99m (99mTc) SestaMIBI intravenously, scintigrams were obtained in two projections comparable to MG. The BSGI was analysed visually and semi-quantitatively by calculating a relative uptake factor (X). With the exception of two patients with cardiac pacemakers, all patients underwent 3-T breast MRI. Biopsy results were obtained as the reference standard in all patients. Sensitivity, specificity, positive- and negative-predictive values, accuracy and area under the curve were calculated for each modality. Results: Among the 92 lesions, 67 (72.8%) were malignant. 60 of the 67 cancers of any size were detected by BSGI with an overall sensitivity of 90%, only exceeded by ultrasound with a sensitivity of 99%. The sensitivity of BSGI for lesions <1 cm declined significantly to 60%. Overall specificity of ultrasound was only 20%. Specificity, accuracy and positive-predictive value were the highest for BSGI (56%, 80% and 85%, respectively). X was significantly higher for malignant lesions (mean, 4.27) and differed significantly between ductal types (mean, 4.53) and the other histopathological entities (mean, 3.12). Conclusion: Semi-quantitative BSGI with calculation of the relative uptake factor (X) can help to characterize breast lesions. BSGI negativity may obviate the need for biopsy of breast lesions >1 cm with low or intermediate prevalence for malignancy. Advances in knowledge: Compared with morphological imaging modalities, specificity, positive

  19. Addition of Adapted Optics towards obtaining a quantitative detection of diabetic retinopathy

    NASA Astrophysics Data System (ADS)

    Yust, Brian; Obregon, Isidro; Tsin, Andrew; Sardar, Dhiraj

    2009-04-01

    An adaptive optics system was assembled for correcting the aberrated wavefront of light reflected from the retina. The adaptive optics setup includes a superluminous diode light source, Hartmann-Shack wavefront sensor, deformable mirror, and imaging CCD camera. Aberrations found in the reflected wavefront are caused by changes in the index of refraction along the light path as the beam travels through the cornea, lens, and vitreous humour. The Hartmann-Shack sensor allows for detection of aberrations in the wavefront, which may then be corrected with the deformable mirror. It has been shown that there is a change in the polarization of light reflected from neovascularizations in the retina due to certain diseases, such as diabetic retinopathy. The adaptive optics system was assembled towards the goal of obtaining a quantitative measure of onset and progression of this ailment, as one does not currently exist. The study was done to show that the addition of adaptive optics results in a more accurate detection of neovascularization in the retina by measuring the expected changes in polarization of the corrected wavefront of reflected light.

  20. Quantitative cultures of endotracheal aspirates for the diagnosis of ventilator-associated pneumonia.

    PubMed

    el-Ebiary, M; Torres, A; González, J; de la Bellacasa, J P; García, C; Jiménez de Anta, M T; Ferrer, M; Rodriguez-Roisin, R

    1993-12-01

    Bronchoalveolar lavage (BAL) and protected specimen brushing (PSB) are the most commonly used methods for diagnosing ventilator-associated (VA) pneumonia although they require bronchoscopy. Endotracheal aspiration (EA) is a simple and less costly technique than PSB or BAL. The purpose of our study was to investigate the diagnostic value of EA quantitative cultures and to compare the results obtained using EA with those obtained using PSB and BAL in mechanically ventilated patients with or without pneumonia. We prospectively studied 102 intubated patients divided into three diagnostic categories: Group I (definite pneumonia, n = 26), Group II (uncertain status, n = 48), and Group III (control group, n = 28). All patients received prior antibiotic treatment. EA, PSB, and BAL were obtained sequentially in all patients. When comparing Group I with Group III and using 10(5) cfu/ml as a threshold, we found that EA quantitative cultures represented a relatively sensitive (70%) and relatively specific (72%) method to diagnose VA pneumonia. The specificity of BAL and PSB (87% and 93%, respectively) was better than that of EA. The negative predictive value of EA cultures was higher (72%) when compared with that obtained using PSB (34%) (p < 0.05). EA quantitative cultures correlated with PSB and BAL quantitative cultures in patients with definite pneumonia. Although EA quantitative cultures are less specific than PSB and BAL for diagnosing VA pneumonia, our results suggest that the former approach may be used to treat these patients when bronchoscopic procedures are not available.

  1. A quantitative analysis of biodiversity and the recreational value of potential national parks in Denmark.

    PubMed

    Larsen, Frank Wugt; Petersen, Anders Højgård; Strange, Niels; Lund, Mette Palitzsch; Rahbek, Carsten

    2008-05-01

    Denmark has committed itself to the European 2010 target to halt the loss of biodiversity. Currently, Denmark is in the process of designating larger areas as national parks, and 7 areas (of a possible 32 larger nature areas) have been selected for pilot projects to test the feasibility of establishing national parks. In this article, we first evaluate the effectiveness of the a priori network of national parks proposed through expert and political consensus versus a network chosen specifically for biodiversity through quantitative analysis. Second, we analyze the potential synergy between preserving biodiversity in terms of species representation and recreational values in selecting a network of national parks. We use the actual distribution of 973 species within these 32 areas and 4 quantitative measures of recreational value. Our results show that the 7 pilot project areas are not significantly more effective in representing species than expected by chance and that considerably more efficient networks can be selected. Moreover, it is possible to select more-effective networks of areas that combine high representation of species with high ranking in terms of recreational values. Therefore, our findings suggest possible synergies between outdoor recreation and biodiversity conservation when selecting networks of national parks. Overall, this Danish case illustrates that data-driven analysis can not only provide valuable information to guide the decision-making process of designating national parks, but it can also be a means to identify solutions that simultaneously fulfill several goals (biodiversity preservation and recreational values).

  2. 41 CFR 102-75.305 - What type of appraisal value must be obtained for real property disposal transactions?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What type of appraisal value must be obtained for real property disposal transactions? 102-75.305 Section 102-75.305 Public...-75.305 What type of appraisal value must be obtained for real property disposal transactions? For all...

  3. 41 CFR 102-75.305 - What type of appraisal value must be obtained for real property disposal transactions?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false What type of appraisal value must be obtained for real property disposal transactions? 102-75.305 Section 102-75.305 Public...-75.305 What type of appraisal value must be obtained for real property disposal transactions? For all...

  4. 41 CFR 102-75.305 - What type of appraisal value must be obtained for real property disposal transactions?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false What type of appraisal value must be obtained for real property disposal transactions? 102-75.305 Section 102-75.305 Public...-75.305 What type of appraisal value must be obtained for real property disposal transactions? For all...

  5. 41 CFR 102-75.305 - What type of appraisal value must be obtained for real property disposal transactions?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false What type of appraisal value must be obtained for real property disposal transactions? 102-75.305 Section 102-75.305 Public...-75.305 What type of appraisal value must be obtained for real property disposal transactions? For all...

  6. 41 CFR 102-75.305 - What type of appraisal value must be obtained for real property disposal transactions?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false What type of appraisal value must be obtained for real property disposal transactions? 102-75.305 Section 102-75.305 Public...-75.305 What type of appraisal value must be obtained for real property disposal transactions? For all...

  7. Predictive value of EEG in postanoxic encephalopathy: A quantitative model-based approach.

    PubMed

    Efthymiou, Evdokia; Renzel, Roland; Baumann, Christian R; Poryazova, Rositsa; Imbach, Lukas L

    2017-10-01

    The majority of comatose patients after cardiac arrest do not regain consciousness due to severe postanoxic encephalopathy. Early and accurate outcome prediction is therefore essential in determining further therapeutic interventions. The electroencephalogram is a standardized and commonly available tool used to estimate prognosis in postanoxic patients. The identification of pathological EEG patterns with poor prognosis relies however primarily on visual EEG scoring by experts. We introduced a model-based approach of EEG analysis (state space model) that allows for an objective and quantitative description of spectral EEG variability. We retrospectively analyzed standard EEG recordings in 83 comatose patients after cardiac arrest between 2005 and 2013 in the intensive care unit of the University Hospital Zürich. Neurological outcome was assessed one month after cardiac arrest using the Cerebral Performance Category. For a dynamic and quantitative EEG analysis, we implemented a model-based approach (state space analysis) to quantify EEG background variability independent from visual scoring of EEG epochs. Spectral variability was compared between groups and correlated with clinical outcome parameters and visual EEG patterns. Quantitative assessment of spectral EEG variability (state space velocity) revealed significant differences between patients with poor and good outcome after cardiac arrest: Lower mean velocity in temporal electrodes (T4 and T5) was significantly associated with poor prognostic outcome (p<0.005) and correlated with independently identified visual EEG patterns such as generalized periodic discharges (p<0.02). Receiver operating characteristic (ROC) analysis confirmed the predictive value of lower state space velocity for poor clinical outcome after cardiac arrest (AUC 80.8, 70% sensitivity, 15% false positive rate). Model-based quantitative EEG analysis (state space analysis) provides a novel, complementary marker for prognosis in postanoxic

  8. Enhancing value of clinical pharmacodynamics in oncology drug development: An alliance between quantitative pharmacology and translational science.

    PubMed

    Venkatakrishnan, K; Ecsedy, J A

    2017-01-01

    Clinical pharmacodynamic evaluation is a key component of the "pharmacologic audit trail" in oncology drug development. We posit that its value can and should be greatly enhanced via application of a robust quantitative pharmacology framework informed by biologically mechanistic considerations. Herein, we illustrate examples of intersectional blindspots across the disciplines of quantitative pharmacology and translational science and offer a roadmap aimed at enhancing the caliber of clinical pharmacodynamic research in the development of oncology therapeutics. © 2016 American Society for Clinical Pharmacology and Therapeutics.

  9. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    PubMed

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  10. Comparing quantitative values of two generations of laser-assisted indocyanine green dye angiography systems: can we predict necrosis?

    PubMed

    Phillips, Brett T; Fourman, Mitchell S; Rivara, Andrew; Dagum, Alexander B; Huston, Tara L; Ganz, Jason C; Bui, Duc T; Khan, Sami U

    2014-01-01

    Several devices exist today to assist the intraoperative determination of skin flap perfusion. Laser-Assisted Indocyanine Green Dye Angiography (LAICGA) has been shown to accurately predict mastectomy skin flap necrosis using quantitative perfusion values. The laser properties of the latest LAICGA device (SPY Elite) differ significantly from its predecessor system (SPY 2001), preventing direct translation of previous published data. The purpose of this study was to establish a mathematical relationship of perfusion values between these 2 devices. Breast reconstruction patients were prospectively enrolled into a clinical trial where skin flap evaluation and excision was based on quantitative SPY Q values previously established in the literature. Initial study patients underwent mastectomy skin flap evaluation using both SPY systems simultaneously. Absolute perfusion unit (APU) values at identical locations on the breast were then compared graphically. 210 data points were identified on the same patients (n = 4) using both SPY systems. A linear relationship (y = 2.9883x + 12.726) was identified with a high level or correlation (R(2) = 0.744). Previously published values using SPY 2001 (APU 3.7) provided a value of 23.8 APU on the SPY Elite. In addition, postoperative necrosis in these patients correlated to regions of skin identified with the SPY Elite with APU less than 23.8. Intraoperative comparison of LAICGA systems has provided direct correlation of perfusion values predictive of necrosis that were previously established in the literature. An APU value of 3.7 from the SPY 2001 correlates to a SPY Elite APU value of 23.8.

  11. Comparing Quantitative Values of Two Generations of Laser-Assisted Indocyanine Green Dye Angiography Systems: Can We Predict Necrosis?

    PubMed Central

    Fourman, Mitchell S.; Rivara, Andrew; Dagum, Alexander B.; Huston, Tara L.; Ganz, Jason C.; Bui, Duc T.; Khan, Sami U.

    2014-01-01

    Objective: Several devices exist today to assist the intraoperative determination of skin flap perfusion. Laser-Assisted Indocyanine Green Dye Angiography (LAICGA) has been shown to accurately predict mastectomy skin flap necrosis using quantitative perfusion values. The laser properties of the latest LAICGA device (SPY Elite) differ significantly from its predecessor system (SPY 2001), preventing direct translation of previous published data. The purpose of this study was to establish a mathematical relationship of perfusion values between these 2 devices. Methods: Breast reconstruction patients were prospectively enrolled into a clinical trial where skin flap evaluation and excision was based on quantitative SPY Q values previously established in the literature. Initial study patients underwent mastectomy skin flap evaluation using both SPY systems simultaneously. Absolute perfusion unit (APU) values at identical locations on the breast were then compared graphically. Results: 210 data points were identified on the same patients (n = 4) using both SPY systems. A linear relationship (y = 2.9883x + 12.726) was identified with a high level or correlation (R2 = 0.744). Previously published values using SPY 2001 (APU 3.7) provided a value of 23.8 APU on the SPY Elite. In addition, postoperative necrosis in these patients correlated to regions of skin identified with the SPY Elite with APU less than 23.8. Conclusion: Intraoperative comparison of LAICGA systems has provided direct correlation of perfusion values predictive of necrosis that were previously established in the literature. An APU value of 3.7 from the SPY 2001 correlates to a SPY Elite APU value of 23.8. PMID:25525483

  12. Obtaining Approximate Values of Exterior Orientation Elements of Multi-Intersection Images Using Particle Swarm Optimization

    NASA Astrophysics Data System (ADS)

    Li, X.; Li, S. W.

    2012-07-01

    In this paper, an efficient global optimization algorithm in the field of artificial intelligence, named Particle Swarm Optimization (PSO), is introduced into close range photogrammetric data processing. PSO can be applied to obtain the approximate values of exterior orientation elements under the condition that multi-intersection photography and a small portable plane control frame are used. PSO, put forward by an American social psychologist J. Kennedy and an electrical engineer R.C. Eberhart, is a stochastic global optimization method based on swarm intelligence, which was inspired by social behavior of bird flocking or fish schooling. The strategy of obtaining the approximate values of exterior orientation elements using PSO is as follows: in terms of image coordinate observed values and space coordinates of few control points, the equations of calculating the image coordinate residual errors can be given. The sum of absolute value of each image coordinate is minimized to be the objective function. The difference between image coordinate observed value and the image coordinate computed through collinear condition equation is defined as the image coordinate residual error. Firstly a gross area of exterior orientation elements is given, and then the adjustment of other parameters is made to get the particles fly in the gross area. After iterative computation for certain times, the satisfied approximate values of exterior orientation elements are obtained. By doing so, the procedures like positioning and measuring space control points in close range photogrammetry can be avoided. Obviously, this method can improve the surveying efficiency greatly and at the same time can decrease the surveying cost. And during such a process, only one small portable control frame with a couple of control points is employed, and there are no strict requirements for the space distribution of control points. In order to verify the effectiveness of this algorithm, two experiments are

  13. Diagnostic value of (99m)Tc-3PRGD2 scintimammography for differentiation of malignant from benign breast lesions: Comparison of visual and semi-quantitative analysis.

    PubMed

    Chen, Qianqian; Xie, Qian; Zhao, Min; Chen, Bin; Gao, Shi; Zhang, Haishan; Xing, Hua; Ma, Qingjie

    2015-01-01

    To compare the diagnostic value of visual and semi-quantitative analysis of technetium-99m-poly-ethylene glycol, 4-arginine-glycine-aspartic acid ((99m)Tc-3PRGD2) scintimammography (SMG) for better differentiation of benign from malignant breast masses, and also investigate the incremental role of semi-quantitative index of SMG. A total of 72 patients with breast lesions were included in the study. Technetium-99m-3PRGD2 SMG was performed with single photon emission computed tomography (SPET) at 60 min after intravenous injection of 749 ± 86MBq of the radiotracer. Images were evaluated by visual interpretation and semi-quantitative indices of tumor to non-tumor (T/N) ratios, which were compared with pathology results. Receiver operating characteristics (ROC) curve analyses were performed to determine the optimal visual grade, to calculate cut-off values of semi-quantitative indices, and to compare visual and semi-quantitative diagnostic values. Among the 72 patients, 89 lesions were confirmed by histopathology after fine needle aspiration biopsy or surgery, 48 malignant and 41 benign lesions. The mean T/N ratio of (99m)Tc-3PRGD2 SMG in malignant lesions was significantly higher than that in benign lesions (P<0.05). When grade 2 of the disease was used as cut-off value for the detection of primary breast cancer, the sensitivity, specificity and accuracy were 81.3%, 70.7%, and 76.4%, respectively. When a T/N ratio of 2.01 was used as cut-off value, the sensitivity, specificity and accuracy were 79.2%, 75.6%, and 77.5%, respectively. According to ROC analysis, the area under the curve for semi-quantitative analysis was higher than that for visual analysis, but the statistical difference was not significant (P=0.372). Compared with visual analysis or semi-quantitative analysis alone, the sensitivity, specificity and accuracy of visual analysis combined with semi-quantitative analysis in diagnosing primary breast cancer were higher, being: 87.5%, 82.9%, and 85

  14. Quantitative phase analysis and microstructure characterization of magnetite nanocrystals obtained by microwave assisted non-hydrolytic sol–gel synthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sciancalepore, Corrado, E-mail: corrado.sciancalepore@unimore.it; Bondioli, Federica; INSTM Consortium, Via G. Giusti 9, 51121 Firenze

    2015-02-15

    An innovative preparation procedure, based on microwave assisted non-hydrolytic sol–gel synthesis, to obtain spherical magnetite nanoparticles was reported together with a detailed quantitative phase analysis and microstructure characterization of the synthetic products. The nanoparticle growth was analyzed as a function of the synthesis time and was described in terms of crystallization degree employing the Rietveld method on the magnetic nanostructured system for the determination of the amorphous content using hematite as internal standard. Product crystallinity increases as the microwave thermal treatment is increased and reaches very high percentages for synthesis times longer than 1 h. Microstructural evolution of nanocrystals wasmore » followed by the integral breadth methods to obtain information on the crystallite size-strain distribution. The results of diffraction line profile analysis were compared with nanoparticle grain distribution estimated by dimensional analysis of the transmission electron microscopy (TEM) images. A variation both in the average grain size and in the distribution of the coherently diffraction domains is evidenced, allowing to suppose a relationship between the two quantities. The traditional integral breadth methods have proven to be valid for a rapid assessment of the diffraction line broadening effects in the above-mentioned nanostructured systems and the basic assumption for the correct use of these methods are discussed as well. - Highlights: • Fe{sub 3}O{sub 4} nanocrystals were obtained by MW-assisted non-hydrolytic sol–gel synthesis. • Quantitative phase analysis revealed that crystallinity up to 95% was reached. • The strategy of Rietveld refinements was discussed in details. • Dimensional analysis showed nanoparticles ranging from 4 to 8 nm. • Results of integral breadth methods were compared with microscopic analysis.« less

  15. Comparing the rankings obtained from two biodiversity indices: the Fair Proportion Index and the Shapley Value.

    PubMed

    Wicke, Kristina; Fischer, Mareike

    2017-10-07

    The Shapley Value and the Fair Proportion Index of phylogenetic trees have been frequently discussed as prioritization tools in conservation biology. Both indices rank species according to their contribution to total phylogenetic diversity, allowing for a simple conservation criterion. While both indices have their specific advantages and drawbacks, it has recently been shown that both values are closely related. However, as different authors use different definitions of the Shapley Value, the specific degree of relatedness depends on the specific version of the Shapley Value - it ranges from a high correlation index to equality of the indices. In this note, we first give an overview of the different indices. Then we turn our attention to the mere ranking order provided by either of the indices. We compare the rankings obtained from different versions of the Shapley Value for a phylogenetic tree of European amphibians and illustrate their differences. We then undertake further analyses on simulated data and show that even though the chance of two rankings being exactly identical (when obtained from different versions of the Shapley Value) decreases with an increasing number of taxa, the distance between the two rankings converges to zero, i.e., the rankings are becoming more and more alike. Moreover, we introduce our freely available software package FairShapley, which was implemented in Perl and with which all calculations have been performed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Quantitative photothermal phase imaging of red blood cells using digital holographic photothermal microscope.

    PubMed

    Vasudevan, Srivathsan; Chen, George C K; Lin, Zhiping; Ng, Beng Koon

    2015-05-10

    Photothermal microscopy (PTM), a noninvasive pump-probe high-resolution microscopy, has been applied as a bioimaging tool in many biomedical studies. PTM utilizes a conventional phase contrast microscope to obtain highly resolved photothermal images. However, phase information cannot be extracted from these photothermal images, as they are not quantitative. Moreover, the problem of halos inherent in conventional phase contrast microscopy needs to be tackled. Hence, a digital holographic photothermal microscopy technique is proposed as a solution to obtain quantitative phase images. The proposed technique is demonstrated by extracting phase values of red blood cells from their photothermal images. These phase values can potentially be used to determine the temperature distribution of the photothermal images, which is an important study in live cell monitoring applications.

  17. High Resolution Qualitative and Quantitative MR Evaluation of the Glenoid Labrum

    PubMed Central

    Iwasaki, Kenyu; Tafur, Monica; Chang, Eric Y.; SherondaStatum; Biswas, Reni; Tran, Betty; Bae, Won C.; Du, Jiang; Bydder, Graeme M.; Chung, Christine B.

    2015-01-01

    Objective To implement qualitative and quantitative MR sequences for the evaluation of labral pathology. Methods Six glenoid labra were dissected and the anterior and posterior portions were divided into normal, mildly degenerated, or severely degenerated groups using gross and MR findings. Qualitative evaluation was performed using T1-weighted, proton density-weighted (PD), spoiled gradient echo (SPGR) and ultra-short echo time (UTE) sequences. Quantitative evaluation included T2 and T1rho measurements as well as T1, T2*, and T1rho measurements acquired with UTE techniques. Results SPGR and UTE sequences best demonstrated labral fiber structure. Degenerated labra had a tendency towards decreased T1 values, increased T2/T2* values and increased T1 rho values. T2* values obtained with the UTE sequence allowed for delineation between normal, mildly degenerated and severely degenerated groups (p<0.001). Conclusion Quantitative T2* measurements acquired with the UTE technique are useful for distinguishing between normal, mildly degenerated and severely degenerated labra. PMID:26359581

  18. Analysis of a quantitative PCR assay for CMV infection in liver transplant recipients: an intent to find the optimal cut-off value.

    PubMed

    Martín-Dávila, P; Fortún, J; Gutiérrez, C; Martí-Belda, P; Candelas, A; Honrubia, A; Barcena, R; Martínez, A; Puente, A; de Vicente, E; Moreno, S

    2005-06-01

    Preemptive therapy required highly predictive tests for CMV disease. CMV antigenemia assay (pp65 Ag) has been commonly used for rapid diagnosis of CMV infection. Amplification methods for early detection of CMV DNA are under analysis. To compare two diagnostic methods for CMV infection and disease in this population: quantitative PCR (qPCR) performed in two different samples, plasma and leukocytes (PMNs) and using a commercial diagnostic test (COBAS Amplicor Monitor Test) versus pp65 Ag. Prospective study conducted in liver transplant recipients from February 2000 to February 2001. Analyses were performed on 164 samples collected weekly during early post-transplant period from 33 patients. Agreements higher than 78% were observed between the three assays. Optimal qPCR cut-off values were calculated using ROC curves for two specific antigenemia values. For antigenemia >or=10 positive cells, the optimal cut-off value for qPCR in plasma was 1330 copies/ml, with a sensitivity (S) of 58% and a specificity (E) of 98% and the optimal cut-off value for qPCR-cells was 713 copies/5x10(6) cells (S:91.7% and E:86%). Using a threshold of antigenemia >or=20 positive cells, the optimal cut-off values were 1330 copies/ml for qPCR-plasma (S 87%; E 98%) and 4755 copies/5x10(6) cells for qPCR-cells (S 87.5%; E 98%). Prediction values for the three assays were calculated in patients with CMV disease (9 pts; 27%). Considering the assays in a qualitative way, the most sensitive was CMV PCR in cells (S: 100%, E: 54%, PPV: 40%; NPV: 100%). Using specific cut-off values for disease detection the sensitivity, specificity, PPV and NPV for antigenemia >or=10 positive cells were: 89%; 83%; 67%; 95%, respectively. For qPCR-cells >or=713 copies/5x10(6) cells: 100%; 54%; 33% and 100% and for plasma-qPCR>or=1330 copies/ml: 78%, 77%, 47%, 89% respectively. Optimal cut-off for viral load performed in plasma and cells can be obtained for the breakpoint antigenemia value recommended for initiating

  19. [Diagnostic value of quantitative cultures of endotracheal aspirate in ventilator-associated pneumonia: a multicenter study].

    PubMed

    Valencia Arango, M; Torres Martí, A; Insausti Ordeñana, J; Alvarez Lerma, F; Carrasco Joaquinet, N; Herranz Casado, M; Tirapu León, J P

    2003-09-01

    To study the validity of quantitative cultures of tracheal aspirate (TA) in comparison with the plugged telescoping catheter (PTC) for the diagnosis of mechanical ventilator-associated pneumonia. Prospective multicenter study enrolling patients undergoing mechanical ventilation for longer than 72 hours. TA samples were collected from patients with suspected ventilator-associated pneumonia, followed by PTC sampling. Quantitative cultures were performed on all samples. Patients were classified according to the presence or not of pneumonia, based on clinical and radiologic criteria, clinical course and autopsy findings. The cutoff points were > or = 103 colony-forming units (cfu)/mL for PTC cultures; the TA cutoffs analyzed were > or = 105 and > or = 106 cfu/mL. Of the 120 patients studied, 84 had diagnoses of pneumonia and 36 did not (controls). The sensitivity values for TA > or = 106, TA > or = 105, and PTC, respectively, were 54% (95% confidence interval [CI], 42%-64%), 71% (95% CI, 60%-81%), and 68% (95% CI, 57%-78%). The specificity values were 75% (95% CI, 58%-88%), 58% (95% CI, 41%-74%), and 75% (95% CI, 58%-88%), respectively. Staphylococcus aureus was the microorganism most frequently isolated in both TA and PTC samples, followed in frequency by Pseudomomonas aeruginosa in TA samples and Haemophilus influenzae in PTC samples. No significant differences were found between the sensitivity of TA > or = 105 and that of PTC, nor between the specificities of TA > or = 106 and PTC. No differences in the specificities of PTC and TA were found when a TA cutoff of > or = 106 cfu/ml was used. Moreover, at a cutoff of > or = 105 the sensitivity of TA was not statistically different from that of PTC. Quantitative cultures of TA can be considered acceptable for the diagnosis of ventilator-associated pneumonia.

  20. Quantitative structure-permeability relationships at various pH values for acidic and basic drugs and drug-like compounds.

    PubMed

    Oja, M; Maran, U

    2015-01-01

    Absorption in gastrointestinal tract compartments varies and is largely influenced by pH. Therefore, considering pH in studies and analyses of membrane permeability provides an opportunity to gain a better understanding of the behaviour of compounds and to obtain good permeability estimates for prediction purposes. This study concentrates on relationships between the chemical structure and membrane permeability of acidic and basic drugs and drug-like compounds. The membrane permeability of 36 acidic and 61 basic compounds was measured using the parallel artificial membrane permeability assay (PAMPA) at pH 3, 5, 7.4 and 9. Descriptive and/or predictive single-parameter quantitative structure-permeability relationships were derived for all pH values. For acidic compounds, membrane permeability is mainly influenced by hydrogen bond donor properties, as revealed by models with r(2) > 0.8 for pH 3 and pH 5. For basic compounds, the best (r(2) > 0.7) structure-permeability relationships are obtained with the octanol-water distribution coefficient for pH 7.4 and pH 9, indicating the importance of partition properties. In addition to the validation set, the prediction quality of the developed models was tested with folic acid and astemizole, showing good matches between experimental and calculated membrane permeabilities at key pHs. Selected QSAR models are available at the QsarDB repository ( http://dx.doi.org/10.15152/QDB.166 ).

  1. A comparison of manual and quantitative elbow strength testing.

    PubMed

    Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R

    2012-10-01

    The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.

  2. The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women.

    PubMed

    Bruijn, Merel M C; Kamphuis, Esme I; Hoesli, Irene M; Martinez de Tejada, Begoña; Loccufier, Anne R; Kühnert, Maritta; Helmer, Hanns; Franz, Marie; Porath, Martina M; Oudijk, Martijn A; Jacquemyn, Yves; Schulzke, Sven M; Vetter, Grit; Hoste, Griet; Vis, Jolande Y; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan

    2016-12-01

    The combination of the qualitative fetal fibronectin test and cervical length measurement has a high negative predictive value for preterm birth within 7 days; however, positive prediction is poor. A new bedside quantitative fetal fibronectin test showed potential additional value over the conventional qualitative test, but there is limited evidence on the combination with cervical length measurement. The purpose of this study was to compare quantitative fetal fibronectin and qualitative fetal fibronectin testing in the prediction of spontaneous preterm birth within 7 days in symptomatic women who undergo cervical length measurement. We performed a European multicenter cohort study in 10 perinatal centers in 5 countries. Women between 24 and 34 weeks of gestation with signs of active labor and intact membranes underwent quantitative fibronectin testing and cervical length measurement. We assessed the risk of preterm birth within 7 days in predefined strata based on fibronectin concentration and cervical length. Of 455 women who were included in the study, 48 women (11%) delivered within 7 days. A combination of cervical length and qualitative fibronectin resulted in the identification of 246 women who were at low risk: 164 women with a cervix between 15 and 30 mm and a negative fibronectin test (<50 ng/mL; preterm birth rate, 2%) and 82 women with a cervix at >30 mm (preterm birth rate, 2%). Use of quantitative fibronectin alone resulted in a predicted risk of preterm birth within 7 days that ranged from 2% in the group with the lowest fibronectin level (<10 ng/mL) to 38% in the group with the highest fibronectin level (>500 ng/mL), with similar accuracy as that of the combination of cervical length and qualitative fibronectin. Combining cervical length and quantitative fibronectin resulted in the identification of an additional 19 women at low risk (preterm birth rate, 5%), using a threshold of 10 ng/mL in women with a cervix at <15 mm, and 6 women at high risk

  3. Laser gingival retraction: a quantitative assessment.

    PubMed

    Krishna Ch, Vamsi; Gupta, Nidhi; Reddy, K Mahendranadh; Sekhar, N Chandra; Aditya, Venkata; Reddy, G V K Mohan

    2013-08-01

    Proper gingival retraction improves the prognosis of crowns and bridges with sub gingival finishlines.Use of lasers assists the operator to achieve proper retraction with good clinical results. The present study was intended to assess the amount of lateral gingival retraction achieved quantitatively by using diode lasers. Study was carried on 20 patients attended to a dental institution that underwent root canal treatment and indicated for fabrication of crowns. Gingival retraction was carried out on 20 teeth and elastomeric impressions were obtained. Models retrieved from the impressions were sectioned and the lateral distance between finish line and the marginal gingival was measured using tool makers microscope. Retraction was measured in mid buccal, mesio buccal and disto buccal regions. The values obtained were used to calculate the mean lateral retraction in microns. Mean retraction values of 399.5 μm, 445.5 μm and 422.5μm were obtained in mid buccal, mesio buccal and disto buccal regions respectively. Gingival Retraction achieved was closer to the thickness of sulcular epithelium and greater than the minimum required retraction of 200um.

  4. Quantitative neonatal glucose-6-phosphate dehydrogenase screening: distribution, reference values, and classification by phenotype.

    PubMed

    Algur, Nurit; Avraham, Irit; Hammerman, Cathy; Kaplan, Michael

    2012-08-01

    To determine enzyme assay reference values for newborns in a Sephardic Jewish population at high risk for glucose-6-phosphate dehydrogenase (G6PD) deficiency. Quantitative G6PD testing was performed on umbilical cord blood. The reduction of nicotinamide adenine dinucleotide phosphate to nicotinamide adenine dinucleotide phosphate-oxidase, reflecting G6PD activity, was measured spectrophotometrically. Hemoglobin (Hb) was measured on the same sample. G6PD activity was recorded as U/g Hb. Males (N = 1502) were separated into 2 distinct groups: those <7 U/g Hb (n = 243 [16.2%], median 0.28 U/g Hb), designated G6PD deficient, presumably hemizygotes; and those ≥ 9 U/g Hb (n = 1256 [83.8%], 18.76 U/g Hb), designated G6PD normal, presumably hemizygotes. Female (n = 1298) values were a continuum and were categorized based on the male distribution: those <7 U/g Hb (n = 81 [6.2%], 4.84 U/g Hb), G6PD deficient, probably homozogytes; those ≥ 9.5 U/g Hb, equivalent to 50% of the male normal value, (n = 1153 (88.8%), 18.36 U/g Hb), G6PD normal, probably homozygotes; and those with intermediate values (n = 64 [4.9%], 8.61 U/g Hb), probable heterozygotes. Accurate identification of the male G6PD-deficient state was possible despite high normal neonatal G6PD values. Female values were presented as a continuum preventing accurate classification but were classified based on male phenotype for practical use. Copyright © 2012 Mosby, Inc. All rights reserved.

  5. The ACCE method: an approach for obtaining quantitative or qualitative estimates of residual confounding that includes unmeasured confounding

    PubMed Central

    Smith, Eric G.

    2015-01-01

    straightforward.  The method's routine usefulness, however, has not yet been established, nor has the method been fully validated. Rapid further investigation of this novel method is clearly indicated, given the potential value of its quantitative or qualitative output. PMID:25580226

  6. Prognostic Value of the Amount of Bleeding After Aneurysmal Subarachnoid Hemorrhage: A Quantitative Volumetric Study.

    PubMed

    Lagares, Alfonso; Jiménez-Roldán, Luis; Gomez, Pedro A; Munarriz, Pablo M; Castaño-León, Ana M; Cepeda, Santiago; Alén, José F

    2015-12-01

    Quantitative estimation of the hemorrhage volume associated with aneurysm rupture is a new tool of assessing prognosis. To determine the prognostic value of the quantitative estimation of the amount of bleeding after aneurysmal subarachnoid hemorrhage, as well the relative importance of this factor related to other prognostic indicators, and to establish a possible cut-off value of volume of bleeding related to poor outcome. A prospective cohort of 206 patients consecutively admitted with the diagnosis of aneurysmal subarachnoid hemorrhage to Hospital 12 de Octubre were included in the study. Subarachnoid, intraventricular, intracerebral, and total bleeding volumes were calculated using analytic software. For assessing factors related to prognosis, univariate and multivariate analysis (logistic regression) were performed. The relative importance of factors in determining prognosis was established by calculating their proportion of explained variation. Maximum Youden index was calculated to determine the optimal cut point for subarachnoid and total bleeding volume. Variables independently related to prognosis were clinical grade at admission, age, and the different bleeding volumes. The proportion of variance explained is higher for subarachnoid bleeding. The optimal cut point related to poor prognosis is a volume of 20 mL both for subarachnoid and total bleeding. Volumetric measurement of subarachnoid or total bleeding volume are both independent prognostic factors in patients with aneurysmal subarachnoid hemorrhage. A volume of more than 20 mL of blood in the initial noncontrast computed tomography is related to a clear increase in poor outcome risk. : aSAH, aneurysmal subarachnoid hemorrhage.

  7. Evaluation of resin infiltration using quantitative light-induced fluorescence technology.

    PubMed

    Min, Ji-Hyun; Inaba, Daisuke; Kim, Baek-Il

    2016-09-01

    To determine whether quantitative light-induced fluorescence (QLF) technology can be used to classify the colour of teeth specimens before and after resin infiltration (RI) treatment, and calculate the correlation between the ΔF value and colour difference (ΔE) in fluorescence images of the specimens obtained using a QLF-digital (QLF-D) device. Sixty sound bovine permanent teeth specimens were immersed in demineralized solution. Two exposed windows were formed in each specimen, and RI treatment was applied to one of them. The ΔE values were obtained for the differences between a sound tooth surface (SS), an early dental caries surface (ECS) and an ECS treated with RI (RS) in white-light and fluorescence images obtained using QLF-D, respectively. The ΔF value was obtained from fluorescence images using dedicated software for QLF-D. The mean differences between the ΔE values obtained from the white-light and fluorescence images were analyzed by paired t-test. Pearson correlation analysis and Bland-Altman plots were applied to the differences between the ΔF value for ECS (ΔFSS-ECS) and the ΔE value between SS and ECS (ΔESS-ECS), and between the ΔF value for RS (ΔFSS-RS) and the ΔE value between SS and RS (ΔESS-RS) in fluorescence images. The ΔE values obtained from fluorescence images were three times higher than the ΔE values obtained from white-light images (p<0.001). Significant correlations were confirmed between ΔESS-ECS and ΔFSS-ECS (r=-0.492, p<0.001) and between ΔESS-RS and ΔFSS-RS (r=-0.661, p<0.001). QLF technology can be used to confirm the presence of RI in teeth. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Qualitative, semi-quantitative, and quantitative simulation of the osmoregulation system in yeast

    PubMed Central

    Pang, Wei; Coghill, George M.

    2015-01-01

    In this paper we demonstrate how Morven, a computational framework which can perform qualitative, semi-quantitative, and quantitative simulation of dynamical systems using the same model formalism, is applied to study the osmotic stress response pathway in yeast. First the Morven framework itself is briefly introduced in terms of the model formalism employed and output format. We then built a qualitative model for the biophysical process of the osmoregulation in yeast, and a global qualitative-level picture was obtained through qualitative simulation of this model. Furthermore, we constructed a Morven model based on existing quantitative model of the osmoregulation system. This model was then simulated qualitatively, semi-quantitatively, and quantitatively. The obtained simulation results are presented with an analysis. Finally the future development of the Morven framework for modelling the dynamic biological systems is discussed. PMID:25864377

  9. The value of assessing pulmonary venous flow velocity for predicting severity of mitral regurgitation: A quantitative assessment integrating left ventricular function

    NASA Technical Reports Server (NTRS)

    Pu, M.; Griffin, B. P.; Vandervoort, P. M.; Stewart, W. J.; Fan, X.; Cosgrove, D. M.; Thomas, J. D.

    1999-01-01

    Although alteration in pulmonary venous flow has been reported to relate to mitral regurgitant severity, it is also known to vary with left ventricular (LV) systolic and diastolic dysfunction. There are few data relating pulmonary venous flow to quantitative indexes of mitral regurgitation (MR). The object of this study was to assess quantitatively the accuracy of pulmonary venous flow for predicting MR severity by using transesophageal echocardiographic measurement in patients with variable LV dysfunction. This study consisted of 73 patients undergoing heart surgery with mild to severe MR. Regurgitant orifice area (ROA), regurgitant stroke volume (RSV), and regurgitant fraction (RF) were obtained by quantitative transesophageal echocardiography and proximal isovelocity surface area. Both left and right upper pulmonary venous flow velocities were recorded and their patterns classified by the ratio of systolic to diastolic velocity: normal (>/=1), blunted (<1), and systolic reversal (<0). Twenty-three percent of patients had discordant patterns between the left and right veins. When the most abnormal patterns either in the left or right vein were used for analysis, the ratio of peak systolic to diastolic flow velocity was negatively correlated with ROA (r = -0.74, P <.001), RSV (r = -0.70, P <.001), and RF (r = -0.66, P <.001) calculated by the Doppler thermodilution method; values were r = -0.70, r = -0.67, and r = -0.57, respectively (all P <.001), for indexes calculated by the proximal isovelocity surface area method. The sensitivity, specificity, and predictive values of the reversed pulmonary venous flow pattern for detecting a large ROA (>0.3 cm(2)) were 69%, 98%, and 97%, respectively. The sensitivity, specificity, and predictive values of the normal pulmonary venous flow pattern for detecting a small ROA (<0.3 cm(2)) were 60%, 96%, and 94%, respectively. However, the blunted pattern had low sensitivity (22%), specificity (61%), and predictive values (30

  10. Practical considerations for obtaining high quality quantitative computed tomography data of the skeletal system.

    PubMed

    Troy, Karen L; Edwards, W Brent

    2018-05-01

    Quantitative CT (QCT) analysis involves the calculation of specific parameters such as bone volume and density from CT image data, and can be a powerful tool for understanding bone quality and quantity. However, without careful attention to detail during all steps of the acquisition and analysis process, data can be of poor- to unusable-quality. Good quality QCT for research requires meticulous attention to detail and standardization of all aspects of data collection and analysis to a degree that is uncommon in a clinical setting. Here, we review the literature to summarize practical and technical considerations for obtaining high quality QCT data, and provide examples of how each recommendation affects calculated variables. We also provide an overview of the QCT analysis technique to illustrate additional opportunities to improve data reproducibility and reliability. Key recommendations include: standardizing the scanner and data acquisition settings, minimizing image artifacts, selecting an appropriate reconstruction algorithm, and maximizing repeatability and objectivity during QCT analysis. The goal of the recommendations is to reduce potential sources of error throughout the analysis, from scan acquisition to the interpretation of results. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Quantitative three-dimensional low-speed wake surveys

    NASA Technical Reports Server (NTRS)

    Brune, G. W.

    1992-01-01

    Theoretical and practical aspects of conducting three-dimensional wake measurements in large wind tunnels are reviewed with emphasis on applications in low-speed aerodynamics. Such quantitative wake surveys furnish separate values for the components of drag, such as profile drag and induced drag, but also measure lift without the use of a balance. In addition to global data, details of the wake flowfield as well as spanwise distributions of lift and drag are obtained. The paper demonstrates the value of this measurement technique using data from wake measurements conducted by Boeing on a variety of low-speed configurations including the complex high-lift system of a transport aircraft.

  12. Qualitative, semi-quantitative, and quantitative simulation of the osmoregulation system in yeast.

    PubMed

    Pang, Wei; Coghill, George M

    2015-05-01

    In this paper we demonstrate how Morven, a computational framework which can perform qualitative, semi-quantitative, and quantitative simulation of dynamical systems using the same model formalism, is applied to study the osmotic stress response pathway in yeast. First the Morven framework itself is briefly introduced in terms of the model formalism employed and output format. We then built a qualitative model for the biophysical process of the osmoregulation in yeast, and a global qualitative-level picture was obtained through qualitative simulation of this model. Furthermore, we constructed a Morven model based on existing quantitative model of the osmoregulation system. This model was then simulated qualitatively, semi-quantitatively, and quantitatively. The obtained simulation results are presented with an analysis. Finally the future development of the Morven framework for modelling the dynamic biological systems is discussed. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  13. Validation of electrical impedance tomography qualitative and quantitative values and comparison of the numeric pain distress score against mammography.

    PubMed

    Juliana, Norsham; Shahar, Suzana; Chelliah, Kanaga Kumari; Ghazali, Ahmad Rohi; Osman, Fazilah; Sahar, Mohd Azmani

    2014-01-01

    Electrical impedance tomography (EIT) is a potential supplement for mammogram screening. This study aimed to evaluate and feasibility of EIT as opposed to mammography and to determine pain perception with both imaging methods. Women undergoing screening mammography at the Radiology Department of National University of Malaysia Medical Centre were randomly selected for EIT imaging. All women were requested to give a pain score after each imaging session. Two independent raters were chosen to define the image findings of EIT. A total of 164 women in the age range from 40 to 65-year-old participated and were divided into two groups; normal and abnormal. EIT sensitivity and specificity for rater 1 were 69.4% and 63.3, whereas for rater 2 they were 55.3% and 57.0% respectively. The reliability for each rater ranged between good to very good (p<0.05). Quantitative values of EIT showed there were significant differences in all values between groups (ANCOVA, p<0.05). Interestingly, EIT scored a median pain score of 1.51±0.75 whereas mammography scored 4.15±0.87 (Mann Whitney U test, p<0.05). From these quantitative values, EIT has the potential as a health discriminating index. Its ability to replace image findings from mammography needs further investigation.

  14. Comparison of oxygen saturation values obtained from fingers on physically restrained or unrestrained sides of the body.

    PubMed

    Korhan, Esra Akin; Yönt, Gülendam Hakverdioğlu; Khorshid, Leyla

    2011-01-01

    The aim of this study was to compare semiexperimentally the pulse oximetry values obtained from a finger on restrained or unrestrained sides of the body. The pulse oximeter provides a noninvasive measurement of the oxygen saturation of hemoglobin in arterial blood. One of the procedures most frequently applied to patients in intensive care units is the application of physical restraint. Circulation problems are the most important complication in patients who are physically restrained. Evaluation of oxygen saturation from body parts in which circulation is impeded or has deteriorated can cause false results. The research sample consisted of 30 hospitalized patients who participated in the study voluntarily and who were concordant with the inclusion criteria of the study. Patient information and patient follow-up forms were used for data collection. Pulse oximetry values were measured simultaneously using OxiMax Nellcor finger sensors from fingers on the restrained and unrestrained sides of the body. Numeric and percentile distributions were used in evaluating the sociodemographic properties of patients. A significant difference was found between the oxygen saturation values obtained from a finger of an arm that had been physically restrained and a finger of an arm that had not been physically restrained. The mean oxygen saturation value measured from a finger of an arm that had been physically restrained was found to be 93.40 (SD, 2.97), and the mean oxygen saturation value measured from a finger of an arm that had not been physically restrained was found to be 95.53 (SD, 2.38). The results of this study indicate that nurses should use a finger of an arm that is not physically restrained when evaluating oxygen saturation values to evaluate them correctly.

  15. Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grimes, Joshua, E-mail: grimes.joshua@mayo.edu; Celler, Anna

    2014-09-15

    Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming themore » same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume

  16. 7 CFR 356.4 - Property valued at $10,000 or less; notice of seizure administrative action to obtain forfeiture.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Property valued at $10,000 or less; notice of seizure... PROCEDURES § 356.4 Property valued at $10,000 or less; notice of seizure administrative action to obtain... notice of seizure and proposed forfeiture as provided in paragraph (c)(1) of this section, by posting for...

  17. Teaching Professionalism in Nursing: A Quantitative Survey of Beginning Student Nurse Perceptions of Professional Values Interpreted within a Leadership Context

    ERIC Educational Resources Information Center

    Corrao, Jocelyn J.

    2016-01-01

    The researcher designed this quantitative dissertation research to explore the perceptions of beginning nursing students toward professionalism in nursing, specific to professional values within the context of curriculum delivery for a leadership and management course in one baccalaureate nursing program. In addition, the researcher reviewed the…

  18. Multivariate linear regression analysis to identify general factors for quantitative predictions of implant stability quotient values

    PubMed Central

    Huang, Hairong; Xu, Zanzan; Shao, Xianhong; Wismeijer, Daniel; Sun, Ping; Wang, Jingxiao

    2017-01-01

    Objectives This study identified potential general influencing factors for a mathematical prediction of implant stability quotient (ISQ) values in clinical practice. Methods We collected the ISQ values of 557 implants from 2 different brands (SICace and Osstem) placed by 2 surgeons in 336 patients. Surgeon 1 placed 329 SICace implants, and surgeon 2 placed 113 SICace implants and 115 Osstem implants. ISQ measurements were taken at T1 (immediately after implant placement) and T2 (before dental restoration). A multivariate linear regression model was used to analyze the influence of the following 11 candidate factors for stability prediction: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting, insertion torque, I-stage or II-stage healing pattern, implant diameter, implant length and T1-T2 time interval. Results The need for bone grafting as a predictor significantly influenced ISQ values in all three groups at T1 (weight coefficients ranging from -4 to -5). In contrast, implant diameter consistently influenced the ISQ values in all three groups at T2 (weight coefficients ranging from 3.4 to 4.2). Other factors, such as sex, age, I/II-stage implantation and bone type, did not significantly influence ISQ values at T2, and implant length did not significantly influence ISQ values at T1 or T2. Conclusions These findings provide a rational basis for mathematical models to quantitatively predict the ISQ values of implants in clinical practice. PMID:29084260

  19. Prognostic Value of Quantitative Metabolic Metrics on Baseline Pre-Sunitinib FDG PET/CT in Advanced Renal Cell Carcinoma

    PubMed Central

    Minamimoto, Ryogo; Barkhodari, Amir; Harshman, Lauren; Srinivas, Sandy; Quon, Andrew

    2016-01-01

    Purpose The objective of this study was to prospectively evaluate various quantitative metrics on FDG PET/CT for monitoring sunitinib therapy and predicting prognosis in patients with metastatic renal cell cancer (mRCC). Methods Seventeen patients (mean age: 59.0 ± 11.6) prospectively underwent a baseline FDG PET/CT and interim PET/CT after 2 cycles (12 weeks) of sunitinib therapy. We measured the highest maximum standardized uptake value (SUVmax) of all identified lesions (highest SUVmax), sum of SUVmax with maximum six lesions (sum of SUVmax), total lesion glycolysis (TLG) and metabolic tumor volume (MTV) from baseline PET/CT and interim PET/CT, and the % decrease in highest SUVmax of lesion (%Δ highest SUVmax), the % decrease in sum of SUVmax, the % decrease in TLG (%ΔTLG) and the % decrease in MTV (%ΔMTV) between baseline and interim PET/CT, and the imaging results were validated by clinical follow-up at 12 months after completion of therapy for progression free survival (PFS). Results At 12 month follow-up, 6/17 (35.3%) patients achieved PFS, while 11/17 (64.7%) patients were deemed to have progression of disease or recurrence within the previous 12 months. At baseline, PET/CT demonstrated metabolically active cancer in all cases. Using baseline PET/CT alone, all of the quantitative imaging metrics were predictive of PFS. Using interim PET/CT, the %Δ highest SUVmax, %Δ sum of SUVmax, and %ΔTLG were also predictive of PFS. Otherwise, interim PET/CT showed no significant difference between the two survival groups regardless of the quantitative metric utilized including MTV and TLG. Conclusions Quantitative metabolic measurements on baseline PET/CT appears to be predictive of PFS at 12 months post-therapy in patients scheduled to undergo sunitinib therapy for mRCC. Change between baseline and interim PET/CT also appeared to have prognostic value but otherwise interim PET/CT after 12 weeks of sunitinib did not appear to be predictive of PFS. PMID:27123976

  20. Comparative characteristics of quantitative indexes for 18F-FDG uptake and metabolic volume in sequentially obtained PET/MRI and PET/CT.

    PubMed

    Lee, Soo Jin; Paeng, Jin Chul; Goo, Jin Mo; Lee, Jeong Min; Cheon, Gi Jeong; Lee, Dong Soo; Chung, June-Key; Kang, Keon Wook

    2017-04-01

    The purpose of this study was to compare quantitative indexes for fluorine-18 fluorodeoxyglucose uptake and metabolic volume between PET/MRI and PET/CT. Sixty-six patients with solid tumors (32 with lung cancer and 34 with pancreatic cancer) who underwent sequential fluorine-18 fluorodeoxyglucose PET/MRI and PET/CT were retrospectively enrolled. On PET images, maximum and peak standardized uptake values (SUVmax and SUVpeak, respectively), and maximum tumor-to-liver ratio (TLRmax) were measured. Metabolic tumor volume (MTV) and total-lesion glycolysis (TLG) with margin thresholds of 50% SUVmax and SUV 2.5 (MTV50%, MTV2.5; TLG50%, TLG2.5, respectively) were compared between PET/MRI and PET/CT, with patients classified into two groups using imaging protocol (the PET/MRI-first and PET/CT-first groups). There were significant correlations of all tested indexes between PET/MRI and PET/CT (r=0.867-0.987, P<0.001). SUVmax and SUVpeak were lower on PET/MRI regardless of imaging protocol (P<0.001 in the PET/MRI-first group). In contrast, TLRmax exhibited reverse results between the PET/MRI-first and PET/CT-first groups. MTV50% and TLG values varied between PET/MRI and PET/CT, as well as between the PET/MRI-first and PET/CT-first groups. However, MTV2.5 was relatively robust against imaging protocol and modality. There are significant correlations of the quantitative indexes between PET/MRI and PET/CT. However, uptake indexes of SUVmax and SUVpeak are lower on PET/MRI than on PET/CT, and volumetric indexes of MTV50% and TLG values also exhibited significant differences. It may be suggested that TLRmax and MTV2.5 are relatively more appropriate indexes than others when PET/MRI and PET/CT are used interchangeably.

  1. Quantitative measurement of carbon isotopic composition in CO2 gas reservoir by Micro-Laser Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Li, Jiajia; Li, Rongxi; Zhao, Bangsheng; Guo, Hui; Zhang, Shuan; Cheng, Jinghua; Wu, Xiaoli

    2018-04-01

    The use of Micro-Laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, 12CO2 and 13CO2 were mixed with N2 at various molar fraction ratios to obtain Raman quantification factors (F12CO2 and F13CO2), which provide a theoretical basis for calculating the δ13C value. And the corresponding values were 0.523 (0 < C12CO2/CN2 < 2) and 1.11998 (0 < C13CO2/CN2 < 1.5) respectively. It has shown that the representative Raman peak area can be used for the determination of δ13C values within the relative errors range of 0.076% to 1.154% in 13CO2/12CO2 binary mixtures when F12CO2/F13CO2 is 0.466972625. In addition, measurement of δ13C values by Micro-Laser Raman analysis were carried out on natural CO2 gas from Shengli Oil-field at room temperature under different pressures. The δ13C values obtained by Micro-Laser Raman spectroscopy technology and Isotope Ratio Mass Spectrometry (IRMS) technology are in good agreement with each other, and the relative errors range of δ13C values is 1.232%-6.964%. This research provides a fundamental analysis tool for determining gas carbon isotope composition (δ13C values) quantitatively by using Micro-Laser Raman spectroscopy. Experiment of results demonstrates that this method has the potential for obtaining δ13C values in natural CO2 gas reservoirs.

  2. What environmental factors influence resumption of valued activities post stroke: a systematic review of qualitative and quantitative findings.

    PubMed

    Jellema, Sandra; van Hees, Suzanne; Zajec, Jana; van der Sande, Rob; Nijhuis-van der Sanden, Maria Wg; Steultjens, Esther Mj

    2017-07-01

    Identify the environmental factors that influence stroke-survivors' reengagement in personally valued activities and determine what specific environmental factors are related to specific valued activity types. PubMed, CINAHL and PsycINFO were searched until June 2016 using multiple search-terms for stroke, activities, disability, and home and community environments. An integrated mixed-method systematic review of qualitative, quantitative and mixed-design studies was conducted. Two researchers independently identified relevant studies, assessed their methodological quality and extracted relevant findings. To validly compare and combine the various findings, all findings were classified and grouped by environmental category and level of evidence. The search yielded 4024 records; 69 studies were included. Most findings came from low-evidence-level studies such as single qualitative studies. All findings were consistent in that the following factors facilitated reengagement post-stroke: personal adapted equipment; accessible environments; transport; services; education and information. Barriers were: others' negative attitudes and behaviour; long distances and inconvenient environmental conditions (such as bad weather). Each type of valued activity, such as mobility or work, had its own pattern of environmental influences, social support was a facilitator to all types of activities. Although in many qualitative studies others' attitudes, behaviour and stroke-related knowledge were seen as important for reengagement, these factors were hardly studied quantitatively. A diversity of environmental factors was related to stroke-survivors' reengagement. Most findings came from low-evidence-level studies so that evidence on causal relationships was scarce. In future, more higher-level-evidence studies, for example on the attitudes of significant others, should be conducted.

  3. Clinical applications of a quantitative analysis of regional lift ventricular wall motion

    NASA Technical Reports Server (NTRS)

    Leighton, R. F.; Rich, J. M.; Pollack, M. E.; Altieri, P. I.

    1975-01-01

    Observations were summarized which may have clinical application. These were obtained from a quantitative analysis of wall motion that was used to detect both hypokinesis and tardokinesis in left ventricular cineangiograms. The method was based on statistical comparisons with normal values for regional wall motion derived from the cineangiograms of patients who were found not to have heart disease.

  4. Groundwater availability in the United States: the value of quantitative regional assessments

    USGS Publications Warehouse

    Dennehy, Kevin F.; Reilly, Thomas E.; Cunningham, William L.

    2015-01-01

    The sustainability of water resources is under continued threat from the challenges associated with a growing population, competing demands, and a changing climate. Freshwater scarcity has become a fact in many areas. Much of the United States surface-water supplies are fully apportioned for use; thus, in some areas the only potential alternative freshwater source that can provide needed quantities is groundwater. Although frequently overlooked, groundwater serves as the principal reserve of freshwater in the US and represents much of the potential supply during periods of drought. Some nations have requirements to monitor and characterize the availability of groundwater such as the European Union’s Water Framework Directive (EPCEU 2000). In the US there is no such national requirement. Quantitative regional groundwater availability assessments, however, are essential to document the status and trends of groundwater availability for the US and make informed water-resource decisions possible now and in the future. Barthel (2014) highlighted that the value of regional groundwater assessments goes well beyond just quantifying the resource so that it can be better managed. The tools and techniques required to evaluate these unique regional systems advance the science of hydrogeology and provide enhanced methods that can benefit local-scale groundwater investigations. In addition, a significant, yet under-utilized benefit is the digital spatial and temporal data sets routinely generated as part of these studies. Even though there is no legal or regulatory requirement for regional groundwater assessments in the US, there is a logical basis for their implementation. The purpose of this essay is to articulate the rationale for and reaffirm the value of regional groundwater assessments primarily in the US; however, the arguments hold for all nations. The importance of the data sets and the methods and model development that occur as part of these assessments is stressed

  5. Three-phase bone scintigraphy for diagnosis of Charcot neuropathic osteoarthropathy in the diabetic foot - does quantitative data improve diagnostic value?

    PubMed

    Fosbøl, M; Reving, S; Petersen, E H; Rossing, P; Lajer, M; Zerahn, B

    2017-01-01

    To investigate whether inclusion of quantitative data on blood flow distribution compared with visual qualitative evaluation improve the reliability and diagnostic performance of 99 m Tc-hydroxymethylene diphosphate three-phase bone scintigraphy (TPBS) in patients suspected for charcot neuropathic osteoarthropathy (CNO) of the foot. A retrospective cohort study of TPBS performed on 148 patients with suspected acute CNO referred from a single specialized diabetes care centre. The quantitative blood flow distribution was calculated based on the method described by Deutsch et al. All scintigraphies were re-evaluated by independent, blinded observers twice with and without quantitative data on blood flow distribution at ankle and focus level, respectively. The diagnostic validity of TPBS was determined by subsequent review of clinical data and radiological examinations. A total of 90 patients (61%) had confirmed diagnosis of CNO. The sensitivity, specificity and accuracy of three-phase bone scintigraphy without/with quantitative data were 89%/88%, 58%/62% and 77%/78%, respectively. The intra-observer agreement improved significantly by adding quantitative data in the evaluation (Kappa value 0·79/0·94). The interobserver agreement was not significantly improved. Adding quantitative data on blood flow distribution in the interpretation of TBPS improves intra-observer variation, whereas no difference in interobserver variation was observed. The sensitivity of TPBS in the diagnosis of CNO is high, but holds limited specificity. Diagnostic performance does not improve using quantitative data in the evaluation. This may be due to the reference intervals applied in the study or the absence of a proper gold standard diagnostic procedure for comparison. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  6. Use of value functions in environmental decisions

    NASA Astrophysics Data System (ADS)

    O'Banion, Kerry

    1980-01-01

    Value functions are devices that allow discrete analyses of environmental impacts to be reconciled to a single quantitative scale of preference. The values obtained can then be “weighted” and combined into measures of the relative desirability of policy alternatives. However, for this methodology to be valid, the set of impacts used must satisfy a number of conditions; and whether or not these are met depends on how the impacts are selected and characterized. This paper generalizes instances where the conditions may be violated and how they may be resolved, and concludes with a few thoughts on how the methodology might be adapted to the routine of bureaucracy.

  7. Comparison of Quantitative Antifungal Testing Methods for Textile Fabrics.

    PubMed

    Imoto, Yasuo; Seino, Satoshi; Nakagawa, Takashi; Yamamoto, Takao A

    2017-01-01

     Quantitative antifungal testing methods for textile fabrics under growth-supportive conditions were studied. Fungal growth activities on unfinished textile fabrics and textile fabrics modified with Ag nanoparticles were investigated using the colony counting method and the luminescence method. Morphological changes of the fungi during incubation were investigated by microscopic observation. Comparison of the results indicated that the fungal growth activity values obtained with the colony counting method depended on the morphological state of the fungi on textile fabrics, whereas those obtained with the luminescence method did not. Our findings indicated that unique characteristics of each testing method must be taken into account for the proper evaluation of antifungal activity.

  8. Quantitative measurement of carbon isotopic composition in CO2 gas reservoir by Micro-Laser Raman spectroscopy.

    PubMed

    Li, Jiajia; Li, Rongxi; Zhao, Bangsheng; Guo, Hui; Zhang, Shuan; Cheng, Jinghua; Wu, Xiaoli

    2018-04-15

    The use of Micro-Laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, 12 CO 2 and 13 CO 2 were mixed with N 2 at various molar fraction ratios to obtain Raman quantification factors (F 12CO2 and F 13CO2 ), which provide a theoretical basis for calculating the δ 13 C value. And the corresponding values were 0.523 (0values within the relative errors range of 0.076% to 1.154% in 13 CO 2 / 12 CO 2 binary mixtures when F 12CO2 /F 13CO2 is 0.466972625. In addition, measurement of δ 13 C values by Micro-Laser Raman analysis were carried out on natural CO 2 gas from Shengli Oil-field at room temperature under different pressures. The δ 13 C values obtained by Micro-Laser Raman spectroscopy technology and Isotope Ratio Mass Spectrometry (IRMS) technology are in good agreement with each other, and the relative errors range of δ 13 C values is 1.232%-6.964%. This research provides a fundamental analysis tool for determining gas carbon isotope composition (δ 13 C values) quantitatively by using Micro-Laser Raman spectroscopy. Experiment of results demonstrates that this method has the potential for obtaining δ 13 C values in natural CO 2 gas reservoirs. Copyright © 2018. Published by Elsevier B.V.

  9. Power Analysis of Artificial Selection Experiments Using Efficient Whole Genome Simulation of Quantitative Traits

    PubMed Central

    Kessner, Darren; Novembre, John

    2015-01-01

    Evolve and resequence studies combine artificial selection experiments with massively parallel sequencing technology to study the genetic basis for complex traits. In these experiments, individuals are selected for extreme values of a trait, causing alleles at quantitative trait loci (QTL) to increase or decrease in frequency in the experimental population. We present a new analysis of the power of artificial selection experiments to detect and localize quantitative trait loci. This analysis uses a simulation framework that explicitly models whole genomes of individuals, quantitative traits, and selection based on individual trait values. We find that explicitly modeling QTL provides qualitatively different insights than considering independent loci with constant selection coefficients. Specifically, we observe how interference between QTL under selection affects the trajectories and lengthens the fixation times of selected alleles. We also show that a substantial portion of the genetic variance of the trait (50–100%) can be explained by detected QTL in as little as 20 generations of selection, depending on the trait architecture and experimental design. Furthermore, we show that power depends crucially on the opportunity for recombination during the experiment. Finally, we show that an increase in power is obtained by leveraging founder haplotype information to obtain allele frequency estimates. PMID:25672748

  10. Inter-rater reliability of motor unit number estimates and quantitative motor unit analysis in the tibialis anterior muscle.

    PubMed

    Boe, S G; Dalton, B H; Harwood, B; Doherty, T J; Rice, C L

    2009-05-01

    To establish the inter-rater reliability of decomposition-based quantitative electromyography (DQEMG) derived motor unit number estimates (MUNEs) and quantitative motor unit (MU) analysis. Using DQEMG, two examiners independently obtained a sample of needle and surface-detected motor unit potentials (MUPs) from the tibialis anterior muscle from 10 subjects. Coupled with a maximal M wave, surface-detected MUPs were used to derive a MUNE for each subject and each examiner. Additionally, size-related parameters of the individual MUs were obtained following quantitative MUP analysis. Test-retest MUNE values were similar with high reliability observed between examiners (ICC=0.87). Additionally, MUNE variability from test-retest as quantified by a 95% confidence interval was relatively low (+/-28 MUs). Lastly, quantitative data pertaining to MU size, complexity and firing rate were similar between examiners. MUNEs and quantitative MU data can be obtained with high reliability by two independent examiners using DQEMG. Establishing the inter-rater reliability of MUNEs and quantitative MU analysis using DQEMG is central to the clinical applicability of the technique. In addition to assessing response to treatments over time, multiple clinicians may be involved in the longitudinal assessment of the MU pool of individuals with disorders of the central or peripheral nervous system.

  11. Quantitative assessment of scatter correction techniques incorporated in next generation dual-source computed tomography

    NASA Astrophysics Data System (ADS)

    Mobberley, Sean David

    Accurate, cross-scanner assessment of in-vivo air density used to quantitatively assess amount and distribution of emphysema in COPD subjects has remained elusive. Hounsfield units (HU) within tracheal air can be considerably more positive than -1000 HU. With the advent of new dual-source scanners which employ dedicated scatter correction techniques, it is of interest to evaluate how the quantitative measures of lung density compare between dual-source and single-source scan modes. This study has sought to characterize in-vivo and phantom-based air metrics using dual-energy computed tomography technology where the nature of the technology has required adjustments to scatter correction. Anesthetized ovine (N=6), swine (N=13: more human-like rib cage shape), lung phantom and a thoracic phantom were studied using a dual-source MDCT scanner (Siemens Definition Flash. Multiple dual-source dual-energy (DSDE) and single-source (SS) scans taken at different energy levels and scan settings were acquired for direct quantitative comparison. Density histograms were evaluated for the lung, tracheal, water and blood segments. Image data were obtained at 80, 100, 120, and 140 kVp in the SS mode (B35f kernel) and at 80, 100, 140, and 140-Sn (tin filtered) kVp in the DSDE mode (B35f and D30f kernels), in addition to variations in dose, rotation time, and pitch. To minimize the effect of cross-scatter, the phantom scans in the DSDE mode was obtained by reducing the tube current of one of the tubes to its minimum (near zero) value. When using image data obtained in the DSDE mode, the median HU values in the tracheal regions of all animals and the phantom were consistently closer to -1000 HU regardless of reconstruction kernel (chapters 3 and 4). Similarly, HU values of water and blood were consistently closer to their nominal values of 0 HU and 55 HU respectively. When using image data obtained in the SS mode the air CT numbers demonstrated a consistent positive shift of up to 35 HU

  12. Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging.

    PubMed

    Zhang, Yuxin; Holmes, James; Rabanillo, Iñaki; Guidon, Arnaud; Wells, Shane; Hernando, Diego

    2018-09-01

    To evaluate the reproducibility of quantitative diffusion measurements obtained with reduced Field of View (rFOV) and Multi-shot EPI (msEPI) acquisitions, using single-shot EPI (ssEPI) as a reference. Diffusion phantom experiments, and prostate diffusion-weighted imaging in healthy volunteers and patients with known or suspected prostate cancer were performed across the three different sequences. Quantitative diffusion measurements of apparent diffusion coefficient, and diffusion kurtosis parameters (healthy volunteers), were obtained and compared across diffusion sequences (rFOV, msEPI, and ssEPI). Other possible confounding factors like b-value combinations and acquisition parameters were also investigated. Both msEPI and rFOV have shown reproducible quantitative diffusion measurements relative to ssEPI; no significant difference in ADC was observed across pulse sequences in the standard diffusion phantom (p = 0.156), healthy volunteers (p ≥ 0.12) or patients (p ≥ 0.26). The ADC values within the non-cancerous central gland and peripheral zone of patients were 1.29 ± 0.17 × 10 -3  mm 2 /s and 1.74 ± 0.23 × 10 -3  mm 2 /s respectively. However, differences in quantitative diffusion parameters were observed across different number of averages for rFOV, and across b-value groups and diffusion models for all the three sequences. Both rFOV and msEPI have the potential to provide high image quality with reproducible quantitative diffusion measurements in prostate diffusion MRI. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. A new method to evaluate image quality of CBCT images quantitatively without observers

    PubMed Central

    Shimizu, Mayumi; Okamura, Kazutoshi; Yoshida, Shoko; Weerawanich, Warangkana; Tokumori, Kenji; Jasa, Gainer R; Yoshiura, Kazunori

    2017-01-01

    Objectives: To develop an observer-free method for quantitatively evaluating the image quality of CBCT images by applying just-noticeable difference (JND). Methods: We used two test objects: (1) a Teflon (polytetrafluoroethylene) plate phantom attached to a dry human mandible; and (2) a block phantom consisting of a Teflon step phantom and an aluminium step phantom. These phantoms had holes with different depths. They were immersed in water and scanned with a CB MercuRay (Hitachi Medical Corporation, Tokyo, Japan) at tube voltages of 120 kV, 100 kV, 80 kV and 60 kV. Superimposed images of the phantoms with holes were used for evaluation. The number of detectable holes was used as an index of image quality. In detecting holes quantitatively, the threshold grey value (ΔG), which differentiated holes from the background, was calculated using a specific threshold (the JND), and we extracted the holes with grey values above ΔG. The indices obtained by this quantitative method (the extracted hole values) were compared with the observer evaluations (the observed hole values). In addition, the contrast-to-noise ratio (CNR) of the shallowest detectable holes and the deepest undetectable holes were measured to evaluate the contribution of CNR to detectability. Results: The results of this evaluation method corresponded almost exactly with the evaluations made by observers. The extracted hole values reflected the influence of different tube voltages. All extracted holes had an area with a CNR of ≥1.5. Conclusions: This quantitative method of evaluating CBCT image quality may be more useful and less time-consuming than evaluation by observation. PMID:28045343

  14. The conventional tuning fork as a quantitative tool for vibration threshold.

    PubMed

    Alanazy, Mohammed H; Alfurayh, Nuha A; Almweisheer, Shaza N; Aljafen, Bandar N; Muayqil, Taim

    2018-01-01

    This study was undertaken to describe a method for quantifying vibration when using a conventional tuning fork (CTF) in comparison to a Rydel-Seiffer tuning fork (RSTF) and to provide reference values. Vibration thresholds at index finger and big toe were obtained in 281 participants. Spearman's correlations were performed. Age, weight, and height were analyzed for their covariate effects on vibration threshold. Reference values at the fifth percentile were obtained by quantile regression. The correlation coefficients between CTF and RSTF values at finger/toe were 0.59/0.64 (P = 0.001 for both). Among covariates, only age had a significant effect on vibration threshold. Reference values for CTF at finger/toe for the age groups 20-39 and 40-60 years were 7.4/4.9 and 5.8/4.6 s, respectively. Reference values for RSTF at finger/toe for the age groups 20-39 and 40-60 years were 6.9/5.5 and 6.2/4.7, respectively. CTF provides quantitative values that are as good as those provided by RSTF. Age-stratified reference data are provided. Muscle Nerve 57: 49-53, 2018. © 2017 Wiley Periodicals, Inc.

  15. Quantitative Susceptibility Mapping of the Midbrain in Parkinson’s Disease

    PubMed Central

    Du, Guangwei; Liu, Tian; Lewis, Mechelle M.; Kong, Lan; Wang, Yi; Connor, James; Mailman, Richard B.; Huang, Xuemei

    2017-01-01

    Background Parkinson’s disease (PD) is marked pathologically by dopamine neuron loss and iron overload in the substantia nigra pars compacta. Midbrain iron content is reported to be increased in PD based on magnetic resonance imaging (MRI) R2* changes. Because quantitative susceptibility mapping is a novel MRI approach to measure iron content, we compared it with R2* for assessing midbrain changes in PD. Methods Quantitative susceptibility mapping and R2* maps were obtained from 47 PD patients and 47 healthy controls. Midbrain susceptibility and R2* values were analyzed by using both voxel-based and region-of-interest approaches in normalized space, and analyzed along with clinical data, including disease duration, Unified Parkinson’s Disease Rating Scale (UPDRS) I, II, and III sub-scores, and levodopa-equivalent daily dosage. All studies were done while PD patients were “on drug.” Results Compared with controls, PD patients showed significantly increased susceptibility values in both right (cluster size = 106 mm3) and left (164 mm3) midbrain, located ventrolateral to the red nucleus that corresponded to the substantia nigra pars compacta. Susceptibility values in this region were correlated significantly with disease duration, UPDRS II, and levodopa-equivalent daily dosage. Conversely, R2* was increased significantly only in a much smaller region (62 mm3) of the left lateral substantia nigra pars compacta and was not significantly correlated with clinical parameters. Conclusion The use of quantitative susceptibility mapping demonstrated marked nigral changes that correlated with clinical PD status more sensitively than R2*. These data suggest that quantitative susceptibility mapping may be a superior imaging biomarker to R2* for estimating brain iron levels in PD. PMID:26362242

  16. Quantitative Ultrasound for Measuring Obstructive Severity in Children with Hydronephrosis.

    PubMed

    Cerrolaza, Juan J; Peters, Craig A; Martin, Aaron D; Myers, Emmarie; Safdar, Nabile; Linguraru, Marius George

    2016-04-01

    We define sonographic biomarkers for hydronephrotic renal units that can predict the necessity of diuretic nuclear renography. We selected a cohort of 50 consecutive patients with hydronephrosis of varying severity in whom 2-dimensional sonography and diuretic mercaptoacetyltriglycine renography had been performed. A total of 131 morphological parameters were computed using quantitative image analysis algorithms. Machine learning techniques were then applied to identify ultrasound based safety thresholds that agreed with the t½ for washout. A best fit model was then derived for each threshold level of t½ that would be clinically relevant at 20, 30 and 40 minutes. Receiver operating characteristic curve analysis was performed. Sensitivity, specificity and area under the receiver operating characteristic curve were determined. Improvement obtained by the quantitative imaging method compared to the Society for Fetal Urology grading system and the hydronephrosis index was statistically verified. For the 3 thresholds considered and at 100% sensitivity the specificities of the quantitative imaging method were 94%, 70% and 74%, respectively. Corresponding area under the receiver operating characteristic curve values were 0.98, 0.94 and 0.94, respectively. Improvement obtained by the quantitative imaging method over the Society for Fetal Urology grade and hydronephrosis index was statistically significant (p <0.05 in all cases). Quantitative imaging analysis of renal sonograms in children with hydronephrosis can identify thresholds of clinically significant washout times with 100% sensitivity to decrease the number of diuretic renograms in up to 62% of children. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Connecting qualitative observation and quantitative measurement for enhancing quantitative literacy in plant anatomy course

    NASA Astrophysics Data System (ADS)

    Nuraeni, E.; Rahmat, A.

    2018-05-01

    Forming of cognitive schemes of plant anatomy concepts is performed by processing of qualitative and quantitative data obtained from microscopic observations. To enhancing student’s quantitative literacy, strategy of plant anatomy course was modified by adding the task to analyze quantitative data produced by quantitative measurement of plant anatomy guided by material course. Participant in this study was 24 biology students and 35 biology education students. Quantitative Literacy test, complex thinking in plant anatomy test and questioner used to evaluate the course. Quantitative literacy capability data was collected by quantitative literacy test with the rubric from the Association of American Colleges and Universities, Complex thinking in plant anatomy by test according to Marzano and questioner. Quantitative literacy data are categorized according to modified Rhodes and Finley categories. The results showed that quantitative literacy of biology education students is better than biology students.

  18. Tool independence for the Web Accessibility Quantitative Metric.

    PubMed

    Vigo, Markel; Brajnik, Giorgio; Arrue, Myriam; Abascal, Julio

    2009-07-01

    The Web Accessibility Quantitative Metric (WAQM) aims at accurately measuring the accessibility of web pages. One of the main features of WAQM among others is that it is evaluation tool independent for ranking and accessibility monitoring scenarios. This article proposes a method to attain evaluation tool independence for all foreseeable scenarios. After demonstrating that homepages have a more similar error profile than any other web page in a given web site, 15 homepages were measured with 10,000 different values of WAQM parameters using EvalAccess and LIFT, two automatic evaluation tools for accessibility. A similar procedure was followed with random pages and with several test files obtaining several tuples that minimise the difference between both tools. One thousand four hundred forty-nine web pages from 15 web sites were measured with these tuples and those values that minimised the difference between the tools were selected. Once the WAQM was tuned, the accessibility of 15 web sites was measured with two metrics for web sites, concluding that even if similar values can be produced, obtaining the same scores is undesirable since evaluation tools behave in a different way.

  19. Cultural Values Predicting Acculturation Orientations: Operationalizing a Quantitative Measure

    ERIC Educational Resources Information Center

    Ehala, Martin

    2012-01-01

    This article proposes that acculturation orientations are related to two sets of cultural values: utilitarianism (Ut) and traditionalism (Tr). While utilitarian values enhance assimilation, traditional values support language and identity maintenance. It is proposed that the propensity to either end of this value opposition can be measured by an…

  20. What Value "Value Added"?

    ERIC Educational Resources Information Center

    Richards, Andrew

    2015-01-01

    Two quantitative measures of school performance are currently used, the average points score (APS) at Key Stage 2 and value-added (VA), which measures the rate of academic improvement between Key Stage 1 and 2. These figures are used by parents and the Office for Standards in Education to make judgements and comparisons. However, simple…

  1. Modern quantitative schlieren techniques

    NASA Astrophysics Data System (ADS)

    Hargather, Michael; Settles, Gary

    2010-11-01

    Schlieren optical techniques have traditionally been used to qualitatively visualize refractive flowfields in transparent media. Modern schlieren optics, however, are increasingly focused on obtaining quantitative information such as temperature and density fields in a flow -- once the sole purview of interferometry -- without the need for coherent illumination. Quantitative data are obtained from schlieren images by integrating the measured refractive index gradient to obtain the refractive index field in an image. Ultimately this is converted to a density or temperature field using the Gladstone-Dale relationship, an equation of state, and geometry assumptions for the flowfield of interest. Several quantitative schlieren methods are reviewed here, including background-oriented schlieren (BOS), schlieren using a weak lens as a "standard," and "rainbow schlieren." Results are presented for the application of these techniques to measure density and temperature fields across a supersonic turbulent boundary layer and a low-speed free-convection boundary layer in air. Modern equipment, including digital cameras, LED light sources, and computer software that make this possible are also discussed.

  2. Feasibility of in situ, high-resolution correlation of tracer uptake with histopathology by quantitative autoradiography of biopsy specimens obtained under 18F-FDG PET/CT guidance.

    PubMed

    Fanchon, Louise M; Dogan, Snjezana; Moreira, Andre L; Carlin, Sean A; Schmidtlein, C Ross; Yorke, Ellen; Apte, Aditya P; Burger, Irene A; Durack, Jeremy C; Erinjeri, Joseph P; Maybody, Majid; Schöder, Heiko; Siegelbaum, Robert H; Sofocleous, Constantinos T; Deasy, Joseph O; Solomon, Stephen B; Humm, John L; Kirov, Assen S

    2015-04-01

    Core biopsies obtained using PET/CT guidance contain bound radiotracer and therefore provide information about tracer uptake in situ. Our goal was to develop a method for quantitative autoradiography of biopsy specimens (QABS), to use this method to correlate (18)F-FDG tracer uptake in situ with histopathology findings, and to briefly discuss its potential application. Twenty-seven patients referred for a PET/CT-guided biopsy of (18)F-FDG-avid primary or metastatic lesions in different locations consented to participate in this institutional review board-approved study, which complied with the Health Insurance Portability and Accountability Act. Autoradiography of biopsy specimens obtained using 5 types of needles was performed immediately after extraction. The response of autoradiography imaging plates was calibrated using dummy specimens with known activity obtained using 2 core-biopsy needle sizes. The calibration curves were used to quantify the activity along biopsy specimens obtained with these 2 needles and to calculate the standardized uptake value, SUVARG. Autoradiography images were correlated with histopathologic findings and fused with PET/CT images demonstrating the position of the biopsy needle within the lesion. Logistic regression analysis was performed to search for an SUVARG threshold distinguishing benign from malignant tissue in liver biopsy specimens. Pearson correlation between SUVARG of the whole biopsy specimen and average SUVPET over the voxels intersected by the needle in the fused PET/CT image was calculated. Activity concentrations were obtained using autoradiography for 20 specimens extracted with 18- and 20-gauge needles. The probability of finding malignancy in a specimen is greater than 50% (95% confidence) if SUVARG is greater than 7.3. For core specimens with preserved shape and orientation and in the absence of motion, one can achieve autoradiography, CT, and PET image registration with spatial accuracy better than 2 mm. The

  3. Quantitative analysis applied to contrast medium extravasation by using the computed-tomography number within the region of interest

    NASA Astrophysics Data System (ADS)

    Lee, Jae-Seung; Im, In-Chul; Kim, Moon-Jib; Goo, Eun-Hoe; Kim, Sun-Ju; Kim, Kwang; Kwak, Byung-Joon

    2014-02-01

    The present study was carried out to present a method to analyze extravasation quantitatively by measuring the computed tomography (CT) number after determining the region of interest (ROI) in the CT images obtained from patients suspected of extravasation induced by contrast medium auto-injection. To achieve this, we divided the study subjects into a group of patients who incurred extravasation and a group of patients who underwent routine scans without incurring extravasation. The CT numbers at IV sites were obtained as reference values, and CT numbers at extravasation sites and hepatic portal veins, respectively, were obtained as relative values. Thereupon, the predicted time for extravasation ( T EP ) and the predicted ratio for extravasation ( R EP ) of an extravasation site were obtained and analyzed quantitatively. In the case of extravasation induced by a dual auto-injector, the values of the CT numbers were confirmed to be lower and the extravasation site to be enlarged when compared to the extravasation induced by a single autoinjector. This is because the physiological saline introduced after the injection of the contrast agent diluted the concentration of the extravasated contrast agent. Additionally, the T EP caused by the auto-injector was about 40 seconds, and we could perform a precise quantitative assessment of the site suspected of extravasation. In conclusion, the dual auto-injection method, despite its advantage of reducing the volume of contrast agent and improving the quality of images for patients with good vascular integrity, was judged to be likely to increase the risk of extravasation and aggravate outcomes for patients with poor vascular integrity by enlarging extravasation sites.

  4. PERFILS: a program for the quantitative treatment of footprinting data.

    PubMed

    Salas, X; Portugal, J

    1993-10-01

    PERFILS, a computer program written in Borland TurboPascal, performs quantitative analysis of footprinting experiments using any IBM PC or compatible microcomputer. The program uses the height of the bands obtained from densitometric scanning of footprinting autoradiographs to calculate a differential cleavage plot. Such a plot displays, on a logarithmic scale, the difference of susceptibility of a DNA fragment to DNase I, or any other cleaving agent, in the presence of any ligand versus the sequence. PERFILS calculates the fractional cleavage values for control and ligand, giving a table of values for each internucleotidic bond and rendering the differential cleavage plot in only a few seconds.

  5. Quantitative influence of risk factors on blood glucose level.

    PubMed

    Chen, Songjing; Luo, Senlin; Pan, Limin; Zhang, Tiemei; Han, Longfei; Zhao, Haixiu

    2014-01-01

    The aim of this study is to quantitatively analyze the influence of risk factors on the blood glucose level, and to provide theory basis for understanding the characteristics of blood glucose change and confirming the intervention index for type 2 diabetes. The quantitative method is proposed to analyze the influence of risk factors on blood glucose using back propagation (BP) neural network. Ten risk factors are screened first. Then the cohort is divided into nine groups by gender and age. According to the minimum error principle, nine BP models are trained respectively. The quantitative values of the influence of different risk factors on the blood glucose change can be obtained by sensitivity calculation. The experiment results indicate that weight is the leading cause of blood glucose change (0.2449). The second factors are cholesterol, age and triglyceride. The total ratio of these four factors reaches to 77% of the nine screened risk factors. And the sensitivity sequences can provide judgment method for individual intervention. This method can be applied to risk factors quantitative analysis of other diseases and potentially used for clinical practitioners to identify high risk populations for type 2 diabetes as well as other disease.

  6. Establishment of the purity values of carbohydrate certified reference materials using quantitative nuclear magnetic resonance and mass balance approach.

    PubMed

    Quan, Can

    2014-06-15

    This work described the assignment of purity values to six carbohydrate certified reference materials, including glucose, fructose, galactose, lactose, xylose and sucrose, according to the ISO Guides 34 and 35. The CRMs' purity values were assigned based on the weighted average of quantitative nuclear magnetic resonance method and mass balance approach with high resolution liquid chromatography - evaporative light scattering detection. All the six CRMs with following value amount fractions: glucose (GBW10062) at a certified purity P ± U (k=2) of (0.99 ± 0.005)%; fructose (GBW10063) at (0.99 ± 0.005)%; galactose (GBW10064) at (0.99 ± 0.007)%; lactose (GBW10065) at (0.99 ± 0.008)%; xylose (GBW10066) at (0.99 ± 0.007)% and sucrose (GBW10067) at (0.99 ± 0.008)%, respectively were certified. The homogeneity of the CRMs was determined by an in-house validated liquid chromatographic method. Potential degradation during storage was also investigated and a shelf-life based on this value was established. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. 7 CFR 356.4 - Property valued at $10,000 or less; notice of seizure administrative action to obtain forfeiture.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 5 2012-01-01 2012-01-01 false Property valued at $10,000 or less; notice of seizure administrative action to obtain forfeiture. 356.4 Section 356.4 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE FORFEITURE...

  8. IDENTIFYING GENETIC ASSOCIATIONS WITH VARIABILITY IN METABOLIC HEALTH AND BLOOD COUNT LABORATORY VALUES: DIVING INTO THE QUANTITATIVE TRAITS BY LEVERAGING LONGITUDINAL DATA FROM AN EHR.

    PubMed

    Verma, Shefali S; Lucas, Anastasia M; Lavage, Daniel R; Leader, Joseph B; Metpally, Raghu; Krishnamurthy, Sarathbabu; Dewey, Frederick; Borecki, Ingrid; Lopez, Alexander; Overton, John; Penn, John; Reid, Jeffrey; Pendergrass, Sarah A; Breitwieser, Gerda; Ritchie, Marylyn D

    2017-01-01

    , separately in the high variance group and the low variance group for each lab variable. We found 717 PheWAS associations that replicated at a p-value less than 0.001. Next, we evaluated the results of this study by comparing the association results between the high and low variance groups. For example, we found 39 SNPs (in multiple genes) associated with ICD-9 250.01 (Type-I diabetes) in patients with high variance of plasma glucose levels, but not in patients with low variance in plasma glucose levels. Another example is the association of 4 SNPs in UMOD with chronic kidney disease in patients with high variance for aspartate aminotransferase (discovery p-value: 8.71×10-09 and replication p-value: 2.03×10-06). In general, we see a pattern of many more statistically significant associations from patients with high variance in the quantitative lab variables, in comparison with the low variance group across all of the 25 laboratory measurements. This study is one of the first of its kind to utilize quantitative trait variance from longitudinal laboratory data to find associations among genetic variants and clinical phenotypes obtained from an EHR, integrating laboratory values and diagnosis codes to understand the genetic complexities of common diseases.

  9. Quantitative Value of Aldosterone-Renin Ratio for Detection of Aldosterone-Producing Adenoma: The Aldosterone-Renin Ratio for Primary Aldosteronism (AQUARR) Study.

    PubMed

    Maiolino, Giuseppe; Rossitto, Giacomo; Bisogni, Valeria; Cesari, Maurizio; Seccia, Teresa Maria; Plebani, Mario; Rossi, Gian Paolo

    2017-05-21

    Current guidelines recommend use of the aldosterone-renin ratio (ARR) for the case detection of primary aldosteronism followed by confirmatory tests to exclude false-positive results from further diagnostic workup. We investigated the hypothesis that this could be unnecessary in patients with a high ARR value if the quantitative information carried by the ARR is taken into due consideration. We interrogated 2 large data sets of prospectively collected patients studied with the same predefined protocol, which included the captopril challenge test. We used an unambiguous diagnosis of aldosterone-producing adenoma as reference index. We also assessed whether the post-captopril ARR and plasma aldosterone concentration fall furnished a diagnostic gain over baseline ARR values. We found that the false-positive rate fell exponentially, and, conversely, the specificity increased with rising ARR values. At receiver operating characteristics curves and diagnostic odds ratio analysis, the high baseline ARR values implied very high positive likelihood ratio and diagnostic odds ratio values. The baseline and post-captopril ARR showed similar diagnostic accuracy (area under the receiver operating characteristics curve) in both the exploratory and validation cohorts, indicating lack of diagnostic gain with this confirmatory test (between-area under the curve difference, 0.005; 95% CI, -0.031 to 0.040; P =0.7 for comparison, and 0.05; 95% CI, -0.061 to 0.064; P =0.051 for comparison, respectively). These results indicate that the ARR conveys key quantitative information that, if properly used, can simplify the diagnostic workup, resulting in saving of money and resources. This can offer the chance of diagnosis and ensuing adrenalectomy to a larger number of hypertensive patients, ultimately resulting in better control of blood pressure. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  10. Characteristics of quantitative perfusion parameters on dynamic contrast‐enhanced MRI in mammographically occult breast cancer

    PubMed Central

    Ryu, Jung Kyu; Rhee, Sun Jung; Song, Jeong Yoon; Cho, Soo Hyun

    2016-01-01

    The purpose of this study was to compare the characteristics of quantitative perfusion parameters obtained from dynamic contrast‐enhanced (DCE) magnetic resonance imaging (MRI) in patients with mammographically occult (MO) breast cancers and those with mammographically visible (MV) breast cancers. Quantitative parameters (AUC, Ktrans,kep,ve,vp, and wi) from 13 MO breast cancers and 16 MV breast cancers were mapped after the DCE‐MRI data were acquired. Various prognostic factors, including axillary nodal status, estrogen receptor (ER), progesterone receptor (PR), Ki‐67, p53, E‐cadherin, and human epidermal growth factor receptor 2 (HER2) were obtained in each group. Fisher's exact test was used to compare any differences of the various prognostic factors between the two groups. The Mann‐Whitney U test was applied to compare the quantitative parameters between these two groups. Finally, Spearman's correlation was used to investigate the relationships between perfusion indices and four factors — age, tumor size, Ki‐67, and p53 — for each group. Although age, tumor size, and the prognostic factors were not statistically different between the two groups, the mean values of the quantitative parameters, except wi in the MV group, were higher than those in the MO group without statistical significance (p=0.219). The kep value was significantly different between the two groups (p=0.048), but the other parameters were not. In the MO group, vp with size, ve with p53, and Ktrans and vp with Ki‐67 had significant correlations (p<0.05). However, in the MV group, only kep showed significant correlation with age. The kep value was only the perfusion parameter of statistical significance between MO and MV breast cancers. PACS number(s): 87.19.U‐, 87.61.‐c PMID:27685105

  11. Quantitative shear wave ultrasound elastography: initial experience in solid breast masses

    PubMed Central

    2010-01-01

    Introduction Shear wave elastography is a new method of obtaining quantitative tissue elasticity data during breast ultrasound examinations. The aims of this study were (1) to determine the reproducibility of shear wave elastography (2) to correlate the elasticity values of a series of solid breast masses with histological findings and (3) to compare shear wave elastography with greyscale ultrasound for benign/malignant classification. Methods Using the Aixplorer® ultrasound system (SuperSonic Imagine, Aix en Provence, France), 53 solid breast lesions were identified in 52 consecutive patients. Two orthogonal elastography images were obtained of each lesion. Observers noted the mean elasticity values in regions of interest (ROI) placed over the stiffest areas on the two elastography images and a mean value was calculated for each lesion. A sub-set of 15 patients had two elastography images obtained by an additional operator. Reproducibility of observations was assessed between (1) two observers analysing the same pair of images and (2) findings from two pairs of images of the same lesion taken by two different operators. All lesions were subjected to percutaneous biopsy. Elastography measurements were correlated with histology results. After preliminary experience with 10 patients a mean elasticity cut off value of 50 kilopascals (kPa) was selected for benign/malignant differentiation. Greyscale images were classified according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS). BI-RADS categories 1-3 were taken as benign while BI-RADS categories 4 and 5 were classified as malignant. Results Twenty-three benign lesions and 30 cancers were diagnosed on histology. Measurement of mean elasticity yielded an intraclass correlation coefficient of 0.99 for two observers assessing the same pairs of elastography images. Analysis of images taken by two independent operators gave an intraclass correlation coefficient of 0.80. Shear

  12. Quantitative shear wave ultrasound elastography: initial experience in solid breast masses.

    PubMed

    Evans, Andrew; Whelehan, Patsy; Thomson, Kim; McLean, Denis; Brauer, Katrin; Purdie, Colin; Jordan, Lee; Baker, Lee; Thompson, Alastair

    2010-01-01

    Shear wave elastography is a new method of obtaining quantitative tissue elasticity data during breast ultrasound examinations. The aims of this study were (1) to determine the reproducibility of shear wave elastography (2) to correlate the elasticity values of a series of solid breast masses with histological findings and (3) to compare shear wave elastography with greyscale ultrasound for benign/malignant classification. Using the Aixplorer® ultrasound system (SuperSonic Imagine, Aix en Provence, France), 53 solid breast lesions were identified in 52 consecutive patients. Two orthogonal elastography images were obtained of each lesion. Observers noted the mean elasticity values in regions of interest (ROI) placed over the stiffest areas on the two elastography images and a mean value was calculated for each lesion. A sub-set of 15 patients had two elastography images obtained by an additional operator. Reproducibility of observations was assessed between (1) two observers analysing the same pair of images and (2) findings from two pairs of images of the same lesion taken by two different operators. All lesions were subjected to percutaneous biopsy. Elastography measurements were correlated with histology results. After preliminary experience with 10 patients a mean elasticity cut off value of 50 kilopascals (kPa) was selected for benign/malignant differentiation. Greyscale images were classified according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS). BI-RADS categories 1-3 were taken as benign while BI-RADS categories 4 and 5 were classified as malignant. Twenty-three benign lesions and 30 cancers were diagnosed on histology. Measurement of mean elasticity yielded an intraclass correlation coefficient of 0.99 for two observers assessing the same pairs of elastography images. Analysis of images taken by two independent operators gave an intraclass correlation coefficient of 0.80. Shear wave elastography versus

  13. [A novel approach to NIR spectral quantitative analysis: semi-supervised least-squares support vector regression machine].

    PubMed

    Li, Lin; Xu, Shuo; An, Xin; Zhang, Lu-Da

    2011-10-01

    In near infrared spectral quantitative analysis, the precision of measured samples' chemical values is the theoretical limit of those of quantitative analysis with mathematical models. However, the number of samples that can obtain accurately their chemical values is few. Many models exclude the amount of samples without chemical values, and consider only these samples with chemical values when modeling sample compositions' contents. To address this problem, a semi-supervised LS-SVR (S2 LS-SVR) model is proposed on the basis of LS-SVR, which can utilize samples without chemical values as well as those with chemical values. Similar to the LS-SVR, to train this model is equivalent to solving a linear system. Finally, the samples of flue-cured tobacco were taken as experimental material, and corresponding quantitative analysis models were constructed for four sample compositions' content(total sugar, reducing sugar, total nitrogen and nicotine) with PLS regression, LS-SVR and S2 LS-SVR. For the S2 LS-SVR model, the average relative errors between actual values and predicted ones for the four sample compositions' contents are 6.62%, 7.56%, 6.11% and 8.20%, respectively, and the correlation coefficients are 0.974 1, 0.973 3, 0.923 0 and 0.948 6, respectively. Experimental results show the S2 LS-SVR model outperforms the other two, which verifies the feasibility and efficiency of the S2 LS-SVR model.

  14. Optimization of metabolite basis sets prior to quantitation in magnetic resonance spectroscopy: an approach based on quantum mechanics

    NASA Astrophysics Data System (ADS)

    Lazariev, A.; Allouche, A.-R.; Aubert-Frécon, M.; Fauvelle, F.; Piotto, M.; Elbayed, K.; Namer, I.-J.; van Ormondt, D.; Graveron-Demilly, D.

    2011-11-01

    High-resolution magic angle spinning (HRMAS) nuclear magnetic resonance (NMR) is playing an increasingly important role for diagnosis. This technique enables setting up metabolite profiles of ex vivo pathological and healthy tissue. The need to monitor diseases and pharmaceutical follow-up requires an automatic quantitation of HRMAS 1H signals. However, for several metabolites, the values of chemical shifts of proton groups may slightly differ according to the micro-environment in the tissue or cells, in particular to its pH. This hampers the accurate estimation of the metabolite concentrations mainly when using quantitation algorithms based on a metabolite basis set: the metabolite fingerprints are not correct anymore. In this work, we propose an accurate method coupling quantum mechanical simulations and quantitation algorithms to handle basis-set changes. The proposed algorithm automatically corrects mismatches between the signals of the simulated basis set and the signal under analysis by maximizing the normalized cross-correlation between the mentioned signals. Optimized chemical shift values of the metabolites are obtained. This method, QM-QUEST, provides more robust fitting while limiting user involvement and respects the correct fingerprints of metabolites. Its efficiency is demonstrated by accurately quantitating 33 signals from tissue samples of human brains with oligodendroglioma, obtained at 11.7 tesla. The corresponding chemical shift changes of several metabolites within the series are also analyzed.

  15. Estimation of brittleness indices for pay zone determination in a shale-gas reservoir by using elastic properties obtained from micromechanics

    NASA Astrophysics Data System (ADS)

    Lizcano-Hernández, Edgar G.; Nicolás-López, Rubén; Valdiviezo-Mijangos, Oscar C.; Meléndez-Martínez, Jaime

    2018-04-01

    The brittleness indices (BI) of gas-shales are computed by using their effective mechanical properties obtained from micromechanical self-consistent modeling with the purpose of assisting in the identification of the more-brittle regions in shale-gas reservoirs, i.e., the so-called ‘pay zone’. The obtained BI are plotted in lambda-rho versus mu-rho λ ρ -μ ρ and Young’s modulus versus Poisson’s ratio E-ν ternary diagrams along with the estimated elastic properties from log data of three productive shale-gas wells where the pay zone is already known. A quantitative comparison between the obtained BI and the well log data allows for the delimitation of regions where BI values could indicate the best reservoir target in regions with the highest shale-gas exploitation potential. Therefore, a range of values for elastic properties and brittleness indexes that can be used as a data source to support the well placement procedure is obtained.

  16. Methods for Quantitative Interpretation of Retarding Field Analyzer Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calvey, J.R.; Crittenden, J.A.; Dugan, G.F.

    2011-03-28

    Over the course of the CesrTA program at Cornell, over 30 Retarding Field Analyzers (RFAs) have been installed in the CESR storage ring, and a great deal of data has been taken with them. These devices measure the local electron cloud density and energy distribution, and can be used to evaluate the efficacy of different cloud mitigation techniques. Obtaining a quantitative understanding of RFA data requires use of cloud simulation programs, as well as a detailed model of the detector itself. In a drift region, the RFA can be modeled by postprocessing the output of a simulation code, and onemore » can obtain best fit values for important simulation parameters with a chi-square minimization method.« less

  17. Characterization and Application of a Grazing Angle Objective for Quantitative Infrared Reflection Microspectroscopy

    NASA Technical Reports Server (NTRS)

    Pepper, Stephen V.

    1995-01-01

    A grazing angle objective on an infrared microspectrometer is studied for quantitative spectroscopy by considering the angular dependence of the incident intensity within the objective's angular aperture. The assumption that there is no angular dependence is tested by comparing the experimental reflectance of Si and KBr surfaces with the reflectance calculated by integrating the Fresnel reflection coefficient over the angular aperture under this assumption. Good agreement was found, indicating that the specular reflectance of surfaces can straight-forwardly be quantitatively integrated over the angular aperture without considering non-uniform incident intensity. This quantitative approach is applied to the thickness determination of dipcoated Krytox on gold. The infrared optical constants of both materials are known, allowing the integration to be carried out. The thickness obtained is in fair agreement with the value determined by ellipsometry in the visible. Therefore, this paper illustrates a method for more quantitative use of a grazing angle objective for infrared reflectance microspectroscopy.

  18. Measurement of lung expansion with computed tomography and comparison with quantitative histology.

    PubMed

    Coxson, H O; Mayo, J R; Behzad, H; Moore, B J; Verburgt, L M; Staples, C A; Paré, P D; Hogg, J C

    1995-11-01

    The total and regional lung volumes were estimated from computed tomography (CT), and the pleural pressure gradient was determined by using the milliliters of gas per gram of tissue estimated from the X-ray attenuation values and the pressure-volume curve of the lung. The data show that CT accurately estimated the volume of the resected lobe but overestimated its weight by 24 +/- 19%. The volume of gas per gram of tissue was less in the gravity-dependent regions due to a pleural pressure gradient of 0.24 +/- 0.08 cmH2O/cm of descent in the thorax. The proportion of tissue to air obtained with CT was similar to that obtained by quantitative histology. We conclude that the CT scan can be used to estimate total and regional lung volumes and that measurements of the proportions of tissue and air within the thorax by CT can be used in conjunction with quantitative histology to evaluate lung structure.

  19. Utilization of coffee by-products obtained from semi-washed process for production of value-added compounds.

    PubMed

    Bonilla-Hermosa, Verónica Alejandra; Duarte, Whasley Ferreira; Schwan, Rosane Freitas

    2014-08-01

    The semi-dry processing of coffee generates significant amounts of coffee pulp and wastewater. This study evaluated the production of bioethanol and volatile compounds of eight yeast strains cultivated in a mixture of these residues. Hanseniaspora uvarum UFLA CAF76 showed the best fermentation performance; hence it was selected to evaluate different culture medium compositions and inoculum size. The best results were obtained with 12% w/v of coffee pulp, 1 g/L of yeast extract and 0.3 g/L of inoculum. Using these conditions, fermentation in 1 L of medium was carried out, achieving higher ethanol yield, productivity and efficiency with values of 0.48 g/g, 0.55 g/L h and 94.11% respectively. Twenty-one volatile compounds corresponding to higher alcohols, acetates, terpenes, aldehydes and volatile acids were identified by GC-FID. Such results indicate that coffee residues show an excellent potential as substrates for production of value-added compounds. H. uvarum demonstrated high fermentative capacity using these residues. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Statistical Model to Analyze Quantitative Proteomics Data Obtained by 18O/16O Labeling and Linear Ion Trap Mass Spectrometry

    PubMed Central

    Jorge, Inmaculada; Navarro, Pedro; Martínez-Acedo, Pablo; Núñez, Estefanía; Serrano, Horacio; Alfranca, Arántzazu; Redondo, Juan Miguel; Vázquez, Jesús

    2009-01-01

    Statistical models for the analysis of protein expression changes by stable isotope labeling are still poorly developed, particularly for data obtained by 16O/18O labeling. Besides large scale test experiments to validate the null hypothesis are lacking. Although the study of mechanisms underlying biological actions promoted by vascular endothelial growth factor (VEGF) on endothelial cells is of considerable interest, quantitative proteomics studies on this subject are scarce and have been performed after exposing cells to the factor for long periods of time. In this work we present the largest quantitative proteomics study to date on the short term effects of VEGF on human umbilical vein endothelial cells by 18O/16O labeling. Current statistical models based on normality and variance homogeneity were found unsuitable to describe the null hypothesis in a large scale test experiment performed on these cells, producing false expression changes. A random effects model was developed including four different sources of variance at the spectrum-fitting, scan, peptide, and protein levels. With the new model the number of outliers at scan and peptide levels was negligible in three large scale experiments, and only one false protein expression change was observed in the test experiment among more than 1000 proteins. The new model allowed the detection of significant protein expression changes upon VEGF stimulation for 4 and 8 h. The consistency of the changes observed at 4 h was confirmed by a replica at a smaller scale and further validated by Western blot analysis of some proteins. Most of the observed changes have not been described previously and are consistent with a pattern of protein expression that dynamically changes over time following the evolution of the angiogenic response. With this statistical model the 18O labeling approach emerges as a very promising and robust alternative to perform quantitative proteomics studies at a depth of several thousand proteins

  1. Calcaneal quantitative ultrasound value for middle-aged and elderly Malaysian Chinese men and its association with age and body anthropometry.

    PubMed

    Chin, Kok-Yong; Ima-Nirwana, Soelaiman; Isa Naina, Mohamed; Norazlina, Mohamed; Ahmad Nazrun, Shuid; Norliza, Muhammad; Faizah, Othman; Farihah, H Suhaimi; Elvy Suhana, Mohd Ramli; Wan Zurinah, Wan Ngah

    2012-01-01

    Quantitative ultrasound (QUS) is a relatively easy, reliable, and safe method for bone status assessment, but reference data for Asian males remain scarce. Our study aimed to determine the values for one QUS parameter, the speed of sound (SOS) at the calcaneus, in Malaysian Chinese men and to determine the association between the SOS and several demographic characteristics, such as age, weight, height, and body mass index. Three hundred forty-eight Malaysian Chinese men aged 40 yr and older were recruited, and their calcaneal QUS value was determined using the CM-200 densitometer (Furuno Electric, Nishinomiya City, Japan). The results indicated a significant correlation between SOS and age, and multiple stepwise regression analysis indicated that age and height were important predictors of SOS. A significant reduction in SOS value was observed when men 60 yr and older were compared with men aged 40-49 yr. Compared with the reference data for Japanese males, Chinese men in Malaysia showed higher SOS values across all the age groups studied. In conclusion, there is an age-related decrease in SOS values in Malaysian Chinese men, and the SOS values established in this study can be used as a reference for future studies. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  2. 7 CFR 356.3 - Property valued at greater than $10,000; notice of seizure and civil action to obtain forfeiture.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 5 2012-01-01 2012-01-01 false Property valued at greater than $10,000; notice of seizure and civil action to obtain forfeiture. 356.3 Section 356.3 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE...

  3. Quantitative estimation of film forming polymer-plasticizer interactions by the Lorentz-Lorenz Law.

    PubMed

    Dredán, J; Zelkó, R; Dávid, A Z; Antal, I

    2006-03-09

    Molar refraction as well as refractive index has many uses. Beyond confirming the identity and purity of a compound, determination of molecular structure and molecular weight, molar refraction is also used in other estimation schemes, such as in critical properties, surface tension, solubility parameter, molecular polarizability, dipole moment, etc. In the present study molar refraction values of polymer dispersions were determined for the quantitative estimation of film forming polymer-plasticizer interactions. Information can be obtained concerning the extent of interaction between the polymer and the plasticizer from the calculation of molar refraction values of film forming polymer dispersions containing plasticizer.

  4. The Defense Logistics Agency Properly Awarded Power Purchase Agreements and the Army Obtained Fair Market Value for Leases Supporting Power Purchase Agreements

    DTIC Science & Technology

    2016-09-28

    Fair Market Value for Leases Supporting Power Purchase Agreements I N T E G R I T Y  E F F I C I E N C Y  A C C O U N T A B I L I T Y  E X... Market Value for Leases Supporting Power Purchase Agreements Visit us at www.dodig.mil September 28, 2016 Objective We determined whether the...Department of the Army properly awarded and obtained fair market value for leases supporting energy production projects. We conducted this audit in

  5. The Incremental Value of Subjective and Quantitative Assessment of 18F-FDG PET for the Prediction of Pathologic Complete Response to Preoperative Chemoradiotherapy in Esophageal Cancer.

    PubMed

    van Rossum, Peter S N; Fried, David V; Zhang, Lifei; Hofstetter, Wayne L; van Vulpen, Marco; Meijer, Gert J; Court, Laurence E; Lin, Steven H

    2016-05-01

    A reliable prediction of a pathologic complete response (pathCR) to chemoradiotherapy before surgery for esophageal cancer would enable investigators to study the feasibility and outcome of an organ-preserving strategy after chemoradiotherapy. So far no clinical parameters or diagnostic studies are able to accurately predict which patients will achieve a pathCR. The aim of this study was to determine whether subjective and quantitative assessment of baseline and postchemoradiation (18)F-FDG PET can improve the accuracy of predicting pathCR to preoperative chemoradiotherapy in esophageal cancer beyond clinical predictors. This retrospective study was approved by the institutional review board, and the need for written informed consent was waived. Clinical parameters along with subjective and quantitative parameters from baseline and postchemoradiation (18)F-FDG PET were derived from 217 esophageal adenocarcinoma patients who underwent chemoradiotherapy followed by surgery. The associations between these parameters and pathCR were studied in univariable and multivariable logistic regression analysis. Four prediction models were constructed and internally validated using bootstrapping to study the incremental predictive values of subjective assessment of (18)F-FDG PET, conventional quantitative metabolic features, and comprehensive (18)F-FDG PET texture/geometry features, respectively. The clinical benefit of (18)F-FDG PET was determined using decision-curve analysis. A pathCR was found in 59 (27%) patients. A clinical prediction model (corrected c-index, 0.67) was improved by adding (18)F-FDG PET-based subjective assessment of response (corrected c-index, 0.72). This latter model was slightly improved by the addition of 1 conventional quantitative metabolic feature only (i.e., postchemoradiation total lesion glycolysis; corrected c-index, 0.73), and even more by subsequently adding 4 comprehensive (18)F-FDG PET texture/geometry features (corrected c-index, 0

  6. Quantitative Finance

    NASA Astrophysics Data System (ADS)

    James, Jessica

    2017-01-01

    Quantitative finance is a field that has risen to prominence over the last few decades. It encompasses the complex models and calculations that value financial contracts, particularly those which reference events in the future, and apply probabilities to these events. While adding greatly to the flexibility of the market available to corporations and investors, it has also been blamed for worsening the impact of financial crises. But what exactly does quantitative finance encompass, and where did these ideas and models originate? We show that the mathematics behind finance and behind games of chance have tracked each other closely over the centuries and that many well-known physicists and mathematicians have contributed to the field.

  7. A novel strategy to obtain quantitative data for modelling: combined enrichment and real-time PCR for enumeration of salmonellae from pig carcasses.

    PubMed

    Krämer, Nadine; Löfström, Charlotta; Vigre, Håkan; Hoorfar, Jeffrey; Bunge, Cornelia; Malorny, Burkhard

    2011-03-01

    Salmonella is a major zoonotic pathogen which causes outbreaks and sporadic cases of gastroenteritis in humans worldwide. The primary sources for Salmonella are food-producing animals such as pigs and poultry. For risk assessment and hazard analysis and critical control point (HACCP) concepts, it is essential to produce large amounts of quantitative data, which is currently not achievable with the standard cultural based methods for enumeration of Salmonella. This study presents the development of a novel strategy to enumerate low numbers of Salmonella in cork borer samples taken from pig carcasses as a first concept and proof of principle for a new sensitive and rapid quantification method based on combined enrichment and real-time PCR. The novelty of the approach is in the short pre-enrichment step, where for most bacteria, growth is in the log phase. The method consists of an 8h pre-enrichment of the cork borer sample diluted 1:10 in non-selective buffered peptone water, followed by DNA extraction, and Salmonella detection and quantification by real-time PCR. The limit of quantification was 1.4 colony forming units (CFU)/20 cm(2) (approximately 10 g) of artificially contaminated sample with 95% confidence interval of ± 0.7 log CFU/sample. The precision was similar to the standard reference most probable number (MPN) method. A screening of 200 potentially naturally contaminated cork borer samples obtained over seven weeks in a slaughterhouse resulted in 25 Salmonella-positive samples. The analysis of salmonellae within these samples showed that the PCR method had a higher sensitivity for samples with a low contamination level (<6.7 CFU/sample), where 15 of the samples negative with the MPN method was detected with the PCR method and 5 were found to be negative by both methods. For the samples with a higher contamination level (6.7-310 CFU/sample) a good agreement between the results obtained with the PCR and MPN methods was obtained. The quantitative real

  8. Correlation between radio-induced lymphocyte apoptosis measurements obtained from two French centres.

    PubMed

    Mirjolet, C; Merlin, J L; Dalban, C; Maingon, P; Azria, D

    2016-07-01

    In the era of modern treatment delivery, increasing the dose delivered to the target to improve local control might be modulated by the patient's intrinsic radio-sensitivity. A predictive assay based on radio-induced lymphocyte apoptosis quantification highlighted the significant correlation between CD4 and CD8 T-lymphocyte apoptosis and grade 2 or 3 radiation-induced late toxicities. By conducting this assay at several technical platforms, the aim of this study was to demonstrate that radio-induced lymphocyte apoptosis values obtained from two different platforms were comparable. For 25 patients included in the PARATOXOR trial running in Dijon the radio-induced lymphocyte apoptosis results obtained from the laboratory of Montpellier (IRCM, Inserm U1194, France), considered as the reference (referred to as Lab 1), were compared with those from the laboratory located at the Institut de cancérologie de Lorraine (ICL, France), referred to as Lab 2. Different statistical methods were used to measure the agreement between the radio-induced lymphocyte apoptosis data from the two laboratories (quantitative data). The Bland-Altman plot was used to identify potential bias. All statistical tests demonstrated good agreement between radio-induced lymphocyte apoptosis values obtained from both sites and no major bias was identified. Since radio-induced lymphocyte apoptosis values, which predict tolerance to radiotherapy, could be assessed by two laboratories and showed a high level of robustness and consistency, we can suggest that this assay be extended to any laboratories that use the same technique. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  9. 3-D Quantitative Dynamic Contrast Ultrasound for Prostate Cancer Localization.

    PubMed

    Schalk, Stefan G; Huang, Jing; Li, Jia; Demi, Libertario; Wijkstra, Hessel; Huang, Pintong; Mischi, Massimo

    2018-04-01

    To investigate quantitative 3-D dynamic contrast-enhanced ultrasound (DCE-US) and, in particular 3-D contrast-ultrasound dispersion imaging (CUDI), for prostate cancer detection and localization, 43 patients referred for 10-12-core systematic biopsy underwent 3-D DCE-US. For each 3-D DCE-US recording, parametric maps of CUDI-based and perfusion-based parameters were computed. The parametric maps were divided in regions, each corresponding to a biopsy core. The obtained parameters were validated per biopsy location and after combining two or more adjacent regions. For CUDI by correlation (r) and for the wash-in time (WIT), a significant difference in parameter values between benign and malignant biopsy cores was found (p < 0.001). In a per-prostate analysis, sensitivity and specificity were 94% and 50% for r, and 53% and 81% for WIT. Based on these results, it can be concluded that quantitative 3-D DCE-US could aid in localizing prostate cancer. Therefore, we recommend follow-up studies to investigate its value for targeting biopsies. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  10. Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay.

    PubMed

    Xu, Ting; Zhang, Qiang; Fan, Ya-Han; Li, Ru-Qing; Lu, Hua; Zhao, Shu-Ming; Jiang, Tian-Lun

    2017-01-01

    Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads. In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples. Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 10 5 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively. In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety.

  11. Technique to quantitatively measure magnetic properties of thin structures at <10 NM spatial resolution

    DOEpatents

    Bajt, Sasa

    2003-07-08

    A highly sensitive and high resolution magnetic microscope images magnetic properties quantitatively. Imaging is done with a modified transmission electron microscope that allows imaging of the sample in a zero magnetic field. Two images from closely spaced planes, one in focus and one slightly out of focus, are sufficient to calculate the absolute values of the phase change imparted to the electrons, and hence obtain the magnetization vector field distribution.

  12. Quantitative ethnobotany in an atlantic forest fragment of northeastern Brazil: implications to conservation.

    PubMed

    Da Cunha, Luiz Vital F Cruz; De Albuquerque, Ulysses P

    2006-03-01

    An ethnobotanical study was executed in the rural community of the Municipality of "Rio Formoso", starting from the forest inventory accomplished in an Atlantic Forest remnant adjacent to the studied community. Using the methodology of quantitative ethnobotany allied to the ecological parameters (richness, relative frequency, relative density, relative dominance and importance value index) the following results were obtained: 42 inventoried species gathered in 26 families, presented from 1 to 27 means of use for the community. The largest use of the plants is related to obtaining wood in order to be used in house building, firewood production and charcoal. The largest use value was attributed to the Vouacapoua virgilioides (Kunth) Kuntze. The most frequent species were Tapirira guianensis Aubl. (Anacardiaceae), Thyrsodium schomburgkianum Benth. (Anacardiaceae), Schefflera morototoni (Aubl.) Maguire, Steyem. & Frodin (Araliaceae) and Dialium guianense (Aubl.) Sandwith. (Leg-Caesalpinioideae).

  13. Value of Quantitative Collateral Scoring on CT Angiography in Patients with Acute Ischemic Stroke.

    PubMed

    Boers, A M M; Sales Barros, R; Jansen, I G H; Berkhemer, O A; Beenen, L F M; Menon, B K; Dippel, D W J; van der Lugt, A; van Zwam, W H; Roos, Y B W E M; van Oostenbrugge, R J; Slump, C H; Majoie, C B L M; Marquering, H A

    2018-06-01

    Many studies have emphasized the relevance of collateral flow in patients presenting with acute ischemic stroke. Our aim was to evaluate the relationship of the quantitative collateral score on baseline CTA with the outcome of patients with acute ischemic stroke and test whether the timing of the CTA acquisition influences this relationship. From the Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands (MR CLEAN) data base, all baseline thin-slice CTA images of patients with acute ischemic stroke with intracranial large-vessel occlusion were retrospectively collected. The quantitative collateral score was calculated as the ratio of the vascular appearance of both hemispheres and was compared with the visual collateral score. Primary outcomes were 90-day mRS score and follow-up infarct volume. The relation with outcome and the association with treatment effect were estimated. The influence of the CTA acquisition phase on the relation of collateral scores with outcome was determined. A total of 442 patients were included. The quantitative collateral score strongly correlated with the visual collateral score (ρ = 0.75) and was an independent predictor of mRS (adjusted odds ratio = 0.81; 95% CI, .77-.86) and follow-up infarct volume (exponent β = 0.88; P < .001) per 10% increase. The quantitative collateral score showed areas under the curve of 0.71 and 0.69 for predicting functional independence (mRS 0-2) and follow-up infarct volume of >90 mL, respectively. We found significant interaction of the quantitative collateral score with the endovascular therapy effect in unadjusted analysis on the full ordinal mRS scale ( P = .048) and on functional independence ( P = .049). Modification of the quantitative collateral score by acquisition phase on outcome was significant (mRS: P = .004; follow-up infarct volume: P < .001) in adjusted analysis. Automated quantitative collateral scoring in patients with acute ischemic

  14. Quantification of osteoblastic activity in epiphyseal growth plates by quantitative bone SPECT/CT.

    PubMed

    Yamane, Tomohiko; Kuji, Ichiei; Seto, Akira; Matsunari, Ichiro

    2018-06-01

    Quantifying the function of the epiphyseal plate is worthwhile for the management of children with growth disorders. The aim of this retrospective study was to quantify the osteoblastic activity at the epiphyseal plate using the quantitative bone SPECT/CT. We enrolled patients under the age of 20 years who received Tc-99m hydroxymethylene diphosphonate bone scintigraphy acquired by a quantitative SPECT/CT scanner. The images were reconstructed by ordered subset conjugate-gradient minimizer, and the uptake on the distal margin of the femur was quantified by peak standardized uptake value (SUVpeak). A public database of standard body height was used to calculate growth velocities (cm/year). Fifteen patients (6.9-19.7 years, 9 female, 6 male) were enrolled and a total of 25 legs were analyzed. SUVpeak in the epiphyseal plate was 18.9 ± 2.4 (average ± standard deviation) in the subjects under 15 years and decreased gradually by aging. The SUVpeak correlated significantly with the age- and sex-matched growth velocity obtained from the database (R 2  = 0.83, p < 0.0001). The SUV measured by quantitative bone SPECT/CT was increased at the epiphyseal plates of children under the age of 15 years in comparison with the older group, corresponding to higher osteoblastic activity. Moreover, this study suggested a correlation between growth velocity and the SUV. Although this is a small retrospective pilot study, the objective and quantitative values measured by the quantitative bone SPECT/CT has the potential to improve the management of children with growth disorder.

  15. Facial asymmetry quantitative evaluation in oculoauriculovertebral spectrum.

    PubMed

    Manara, Renzo; Schifano, Giovanni; Brotto, Davide; Mardari, Rodica; Ghiselli, Sara; Gerunda, Antonio; Ghirotto, Cristina; Fusetti, Stefano; Piacentile, Katherine; Scienza, Renato; Ermani, Mario; Martini, Alessandro

    2016-03-01

    Facial asymmetries in oculoauriculovertebral spectrum (OAVS) patients might require surgical corrections that are mostly based on qualitative approach and surgeon's experience. The present study aimed to develop a quantitative 3D CT imaging-based procedure suitable for maxillo-facial surgery planning in OAVS patients. Thirteen OAVS patients (mean age 3.5 ± 4.0 years; range 0.2-14.2, 6 females) and 13 controls (mean age 7.1 ± 5.3 years; range 0.6-15.7, 5 females) who underwent head CT examination were retrospectively enrolled. Eight bilateral anatomical facial landmarks were defined on 3D CT images (porion, orbitale, most anterior point of frontozygomatic suture, most superior point of temporozygomatic suture, most posterior-lateral point of the maxilla, gonion, condylion, mental foramen) and distance from orthogonal planes (in millimeters) was used to evaluate the asymmetry on each axis and to calculate a global asymmetry index of each anatomical landmark. Mean asymmetry values and relative confidence intervals were obtained from the control group. OAVS patients showed 2.5 ± 1.8 landmarks above the confidence interval while considering the global asymmetry values; 12 patients (92%) showed at least one pathologically asymmetric landmark. Considering each axis, the mean number of pathologically asymmetric landmarks increased to 5.5 ± 2.6 (p = 0.002) and all patients presented at least one significant landmark asymmetry. Modern CT-based 3D reconstructions allow accurate assessment of facial bone asymmetries in patients affected by OAVS. The evaluation as a global score and in different orthogonal axes provides precise quantitative data suitable for maxillo-facial surgical planning. CT-based 3D reconstruction might allow a quantitative approach for planning and following-up maxillo-facial surgery in OAVS patients.

  16. A simple competitive RT-PCR assay for quantitation of HIV-1 subtype B and non-B RNA in plasma.

    PubMed

    Hamatake, Makiko; Nishizawa, Masako; Yamamoto, Naoki; Kato, Shingo; Sugiura, Wataru

    2007-06-01

    An easy, inexpensive competitive RT-PCR assay for HIV-1 RNA quantitation was constructed. A 138-bp sequence in the HIV-1 gag p24 region was selected as the target and co-amplified with competitor RNA containing an internal 44-bp deletion. Quantitation of serial dilutions of control RNA samples prepared from the LAI isolate demonstrated a good linearity (R(2)=0.991) within the range between 10 and 250 copies/sample. The detection limit of the assay was determined to be 3.8 copies/sample by Probit analysis and corresponded to 110 copies/ml in plasma. The intra-assay CV value was 9.1%, and the inter-assay value was 25.9%. Both were comparable to those obtained with commercially available HIV-1 RNA quantitation kits. The correlation efficient for the results obtained in 47 plasma samples from HIV-1-infected individuals (subtype A in 1, subtype B in 25, subtype C in 4, subtype F in 1, and CRF01 AE in 16) with the competitive RT-PCR and Cobas Amplicor HIV-1 Monitor test v1.5 was 0.956 for subtype B and 0.947 for subtype non-B. The assay devised is a good alternative for monitoring antiretroviral therapy in resource-poor countries.

  17. Quantitative Methods in the Study of Local History

    ERIC Educational Resources Information Center

    Davey, Pene

    1974-01-01

    The author suggests how the quantitative analysis of data from census records, assessment roles, and newspapers may be integrated into the classroom. Suggestions for obtaining quantitative data are provided. (DE)

  18. Comparison of semi-quantitative and quantitative dynamic contrast-enhanced MRI evaluations of vertebral marrow perfusion in a rat osteoporosis model.

    PubMed

    Zhu, Jingqi; Xiong, Zuogang; Zhang, Jiulong; Qiu, Yuyou; Hua, Ting; Tang, Guangyu

    2017-11-14

    This study aims to investigate the technical feasibility of semi-quantitative and quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in the assessment of longitudinal changes of marrow perfusion in a rat osteoporosis model, using bone mineral density (BMD) measured by micro-computed tomography (micro-CT) and histopathology as the gold standards. Fifty rats were randomly assigned to the control group (n=25) and ovariectomy (OVX) group whose bilateral ovaries were excised (n=25). Semi-quantitative and quantitative DCE-MRI, micro-CT, and histopathological examinations were performed on lumbar vertebrae at baseline and 3, 6, 9, and 12 weeks after operation. The differences between the two groups in terms of semi-quantitative DCE-MRI parameter (maximum enhancement, E max ), quantitative DCE-MRI parameters (volume transfer constant, K trans ; interstitial volume, V e ; and efflux rate constant, K ep ), micro-CT parameter (BMD), and histopathological parameter (microvessel density, MVD) were compared at each of the time points using an independent-sample t test. The differences in these parameters between baseline and other time points in each group were assessed via Bonferroni's multiple comparison test. A Pearson correlation analysis was applied to assess the relationships between DCE-MRI, micro-CT, and histopathological parameters. In the OVX group, the E max values decreased significantly compared with those of the control group at weeks 6 and 9 (p=0.003 and 0.004, respectively). The K trans values decreased significantly compared with those of the control group from week 3 (p<0.05). However, the V e values decreased significantly only at week 9 (p=0.032), and no difference in the K ep was found between two groups. The BMD values of the OVX group decreased significantly compared with those of the control group from week 3 (p<0.05). Transmission electron microscopy showed tighter gaps between vascular endothelial cells with swollen mitochondria

  19. Quantitative analysis of rectal cancer by spectral domain optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Q. Q.; Wu, X. J.; Tang, T.; Zhu, S. W.; Yao, Q.; Gao, Bruce Z.; Yuan, X. C.

    2012-08-01

    To quantify OCT images of rectal tissue for clinic diagnosis, the scattering coefficient of the tissue is extracted by curve fitting the OCT signals to a confocal single model. A total of 1000 measurements (half and half of normal and malignant tissues) were obtained from 16 recta. The normal rectal tissue has a larger scattering coefficient ranging from 1.09 to 5.41 mm-1 with a mean value of 2.29 mm-1 (std:±0.32), while the malignant group shows lower scattering property and the values ranging from 0.25 to 2.69 mm-1 with a mean value of 1.41 mm-1 (std:±0.18). The peri-cancer of recta has also been investigated to distinguish the difference between normal and malignant rectal tissue. The results demonstrate that the quantitative analysis of the rectal tissue can be used as a promising diagnostic criterion of early rectal cancer, which has great value for clinical medical applications.

  20. Analysis of quantitative data obtained from toxicity studies showing non-normal distribution.

    PubMed

    Kobayashi, Katsumi

    2005-05-01

    The data obtained from toxicity studies are examined for homogeneity of variance, but, usually, they are not examined for normal distribution. In this study I examined the measured items of a carcinogenicity/chronic toxicity study with rats for both homogeneity of variance and normal distribution. It was observed that a lot of hematology and biochemistry items showed non-normal distribution. For testing normal distribution of the data obtained from toxicity studies, the data of the concurrent control group may be examined, and for the data that show a non-normal distribution, non-parametric tests with robustness may be applied.

  1. Usefulness of quantitative susceptibility mapping for the diagnosis of Parkinson disease.

    PubMed

    Murakami, Y; Kakeda, S; Watanabe, K; Ueda, I; Ogasawara, A; Moriya, J; Ide, S; Futatsuya, K; Sato, T; Okada, K; Uozumi, T; Tsuji, S; Liu, T; Wang, Y; Korogi, Y

    2015-06-01

    Quantitative susceptibility mapping allows overcoming several nonlocal restrictions of susceptibility-weighted and phase imaging and enables quantification of magnetic susceptibility. We compared the diagnostic accuracy of quantitative susceptibility mapping and R2* (1/T2*) mapping to discriminate between patients with Parkinson disease and controls. For 21 patients with Parkinson disease and 21 age- and sex-matched controls, 2 radiologists measured the quantitative susceptibility mapping values and R2* values in 6 brain structures (the thalamus, putamen, caudate nucleus, pallidum, substantia nigra, and red nucleus). The quantitative susceptibility mapping values and R2* values of the substantia nigra were significantly higher in patients with Parkinson disease (P < .01); measurements in other brain regions did not differ significantly between patients and controls. For the discrimination of patients with Parkinson disease from controls, receiver operating characteristic analysis suggested that the optimal cutoff values for the substantia nigra, based on the Youden Index, were >0.210 for quantitative susceptibility mapping and >28.8 for R2*. The sensitivity, specificity, and accuracy of quantitative susceptibility mapping were 90% (19 of 21), 86% (18 of 21), and 88% (37 of 42), respectively; for R2* mapping, they were 81% (17 of 21), 52% (11 of 21), and 67% (28 of 42). Pair-wise comparisons showed that the areas under the receiver operating characteristic curves were significantly larger for quantitative susceptibility mapping than for R2* mapping (0.91 versus 0.69, P < .05). Quantitative susceptibility mapping showed higher diagnostic performance than R2* mapping for the discrimination between patients with Parkinson disease and controls. © 2015 by American Journal of Neuroradiology.

  2. Correlations between quantitative fat–water magnetic resonance imaging and computed tomography in human subcutaneous white adipose tissue

    PubMed Central

    Gifford, Aliya; Walker, Ronald C.; Towse, Theodore F.; Brian Welch, E.

    2015-01-01

    Abstract. Beyond estimation of depot volumes, quantitative analysis of adipose tissue properties could improve understanding of how adipose tissue correlates with metabolic risk factors. We investigated whether the fat signal fraction (FSF) derived from quantitative fat–water magnetic resonance imaging (MRI) scans at 3.0 T correlates to CT Hounsfield units (HU) of the same tissue. These measures were acquired in the subcutaneous white adipose tissue (WAT) at the umbilical level of 21 healthy adult subjects. A moderate correlation exists between MRI- and CT-derived WAT values for all subjects, R2=0.54, p<0.0001, with a slope of −2.6, (95% CI [−3.3,−1.8]), indicating that a decrease of 1 HU equals a mean increase of 0.38% FSF. We demonstrate that FSF estimates obtained using quantitative fat–water MRI techniques correlate with CT HU values in subcutaneous WAT, and therefore, MRI-based FSF could be used as an alternative to CT HU for assessing metabolic risk factors. PMID:26702407

  3. Quantitative analysis of titanium concentration using calibration-free laser-induced breakdown spectroscopy (LIBS)

    NASA Astrophysics Data System (ADS)

    Zaitun; Prasetyo, S.; Suliyanti, M. M.; Isnaeni; Herbani, Y.

    2018-03-01

    Laser-induced breakdown spectroscopy (LIBS) can be used for quantitative and qualitative analysis. Calibration-free LIBS (CF-LIBS) is a method to quantitatively analyze concentration of elements in a sample in local thermodynamic equilibrium conditions without using available matrix-matched calibration. In this study, we apply CF-LIBS for quantitative analysis of Ti in TiO2 sample. TiO2 powder sample was mixed with polyvinyl alcohol and formed into pellets. An Nd:YAG pulsed laser at a wavelength of 1064 nm was focused onto the sample to generate plasma. The spectrum of plasma was recorded using spectrophotometer then compared to NIST spectral line to determine energy levels and other parameters. The value of plasma temperature obtained using Boltzmann plot is 8127.29 K and electron density from calculation is 2.49×1016 cm-3. Finally, the concentration of Ti in TiO2 sample from this study is 97% that is in proximity with the sample certificate.

  4. Rapid Quantitative Determination of Squalene in Shark Liver Oils by Raman and IR Spectroscopy.

    PubMed

    Hall, David W; Marshall, Susan N; Gordon, Keith C; Killeen, Daniel P

    2016-01-01

    Squalene is sourced predominantly from shark liver oils and to a lesser extent from plants such as olives. It is used for the production of surfactants, dyes, sunscreen, and cosmetics. The economic value of shark liver oil is directly related to the squalene content, which in turn is highly variable and species-dependent. Presented here is a validated gas chromatography-mass spectrometry analysis method for the quantitation of squalene in shark liver oils, with an accuracy of 99.0 %, precision of 0.23 % (standard deviation), and linearity of >0.999. The method has been used to measure the squalene concentration of 16 commercial shark liver oils. These reference squalene concentrations were related to infrared (IR) and Raman spectra of the same oils using partial least squares regression. The resultant models were suitable for the rapid quantitation of squalene in shark liver oils, with cross-validation r (2) values of >0.98 and root mean square errors of validation of ≤4.3 % w/w. Independent test set validation of these models found mean absolute deviations of the 4.9 and 1.0 % w/w for the IR and Raman models, respectively. Both techniques were more accurate than results obtained by an industrial refractive index analysis method, which is used for rapid, cheap quantitation of squalene in shark liver oils. In particular, the Raman partial least squares regression was suited to quantitative squalene analysis. The intense and highly characteristic Raman bands of squalene made quantitative analysis possible irrespective of the lipid matrix.

  5. Relationship between δ 18O values for skeletal apatite from reindeer and foxes and yearly mean δ 18O values of environmental water

    NASA Astrophysics Data System (ADS)

    Iacumin, Paola; Longinelli, Antonio

    2002-07-01

    The oxygen isotope composition of bone and tooth phosphate of 50 fox specimens and 30 reindeer specimens from various locations with different climatic and environmental conditions was measured. The existing relationship between these values and the mean oxygen isotope composition of local meteoric water has been calculated. In the case of foxes, specimens belonging to two genera ( Vulpes and Alopex) and three different species were measured. The samples fit a straight line whose equation can be used for paleoclimatological studies either in Arctic or in temperate regions. For reindeer ( Rangifer), a relatively large range of isotopic values was obtained from each location, suggesting imperfect equilibrium conditions with environmental water. The calculated equation can be used for semi-quantitative information on local paleowaters at high latitudes only.

  6. Quantitative Monitoring of Microbial Species during Bioleaching of a Copper Concentrate.

    PubMed

    Hedrich, Sabrina; Guézennec, Anne-Gwenaëlle; Charron, Mickaël; Schippers, Axel; Joulian, Catherine

    2016-01-01

    Monitoring of the microbial community in bioleaching processes is essential in order to control process parameters and enhance the leaching efficiency. Suitable methods are, however, limited as they are usually not adapted to bioleaching samples and often no taxon-specific assays are available in the literature for these types of consortia. Therefore, our study focused on the development of novel quantitative real-time PCR (qPCR) assays for the quantification of Acidithiobacillus caldus, Leptospirillum ferriphilum, Sulfobacillus thermosulfidooxidans , and Sulfobacillus benefaciens and comparison of the results with data from other common molecular monitoring methods in order to evaluate their accuracy and specificity. Stirred tank bioreactors for the leaching of copper concentrate, housing a consortium of acidophilic, moderately thermophilic bacteria, relevant in several bioleaching operations, served as a model system. The microbial community analysis via qPCR allowed a precise monitoring of the evolution of total biomass as well as abundance of specific species. Data achieved by the standard fingerprinting methods, terminal restriction fragment length polymorphism (T-RFLP) and capillary electrophoresis single strand conformation polymorphism (CE-SSCP) on the same samples followed the same trend as qPCR data. The main added value of qPCR was, however, to provide quantitative data for each species whereas only relative abundance could be deduced from T-RFLP and CE-SSCP profiles. Additional value was obtained by applying two further quantitative methods which do not require nucleic acid extraction, total cell counting after SYBR Green staining and metal sulfide oxidation activity measurements via microcalorimetry. Overall, these complementary methods allow for an efficient quantitative microbial community monitoring in various bioleaching operations.

  7. Quantitative Monitoring of Microbial Species during Bioleaching of a Copper Concentrate

    PubMed Central

    Hedrich, Sabrina; Guézennec, Anne-Gwenaëlle; Charron, Mickaël; Schippers, Axel; Joulian, Catherine

    2016-01-01

    Monitoring of the microbial community in bioleaching processes is essential in order to control process parameters and enhance the leaching efficiency. Suitable methods are, however, limited as they are usually not adapted to bioleaching samples and often no taxon-specific assays are available in the literature for these types of consortia. Therefore, our study focused on the development of novel quantitative real-time PCR (qPCR) assays for the quantification of Acidithiobacillus caldus, Leptospirillum ferriphilum, Sulfobacillus thermosulfidooxidans, and Sulfobacillus benefaciens and comparison of the results with data from other common molecular monitoring methods in order to evaluate their accuracy and specificity. Stirred tank bioreactors for the leaching of copper concentrate, housing a consortium of acidophilic, moderately thermophilic bacteria, relevant in several bioleaching operations, served as a model system. The microbial community analysis via qPCR allowed a precise monitoring of the evolution of total biomass as well as abundance of specific species. Data achieved by the standard fingerprinting methods, terminal restriction fragment length polymorphism (T-RFLP) and capillary electrophoresis single strand conformation polymorphism (CE-SSCP) on the same samples followed the same trend as qPCR data. The main added value of qPCR was, however, to provide quantitative data for each species whereas only relative abundance could be deduced from T-RFLP and CE-SSCP profiles. Additional value was obtained by applying two further quantitative methods which do not require nucleic acid extraction, total cell counting after SYBR Green staining and metal sulfide oxidation activity measurements via microcalorimetry. Overall, these complementary methods allow for an efficient quantitative microbial community monitoring in various bioleaching operations. PMID:28066365

  8. Quantitative breast MRI radiomics for cancer risk assessment and the monitoring of high-risk populations

    NASA Astrophysics Data System (ADS)

    Mendel, Kayla R.; Li, Hui; Giger, Maryellen L.

    2016-03-01

    Breast density is routinely assessed qualitatively in screening mammography. However, it is challenging to quantitatively determine a 3D density from a 2D image such as a mammogram. Furthermore, dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used more frequently in the screening of high-risk populations. The purpose of our study is to segment parenchyma and to quantitatively determine volumetric breast density on pre-contrast axial DCE-MRI images (i.e., non-contrast) using a semi-automated quantitative approach. In this study, we retroactively examined 3D DCE-MRI images taken for breast cancer screening of a high-risk population. We analyzed 66 cases with ages between 28 and 76 (mean 48.8, standard deviation 10.8). DCE-MRIs were obtained on a Philips 3.0 T scanner. Our semi-automated DCE-MRI algorithm includes: (a) segmentation of breast tissue from non-breast tissue using fuzzy cmeans clustering (b) separation of dense and fatty tissues using Otsu's method, and (c) calculation of volumetric density as the ratio of dense voxels to total breast voxels. We examined the relationship between pre-contrast DCE-MRI density and clinical BI-RADS density obtained from radiology reports, and obtained a statistically significant correlation [Spearman ρ-value of 0.66 (p < 0.0001)]. Our method within precision medicine may be useful for monitoring high-risk populations.

  9. Quantitative Oxygenation Venography from MRI Phase

    PubMed Central

    Fan, Audrey P.; Bilgic, Berkin; Gagnon, Louis; Witzel, Thomas; Bhat, Himanshu; Rosen, Bruce R.; Adalsteinsson, Elfar

    2014-01-01

    Purpose To demonstrate acquisition and processing methods for quantitative oxygenation venograms that map in vivo oxygen saturation (SvO2) along cerebral venous vasculature. Methods Regularized quantitative susceptibility mapping (QSM) is used to reconstruct susceptibility values and estimate SvO2 in veins. QSM with ℓ1 and ℓ2 regularization are compared in numerical simulations of vessel structures with known magnetic susceptibility. Dual-echo, flow-compensated phase images are collected in three healthy volunteers to create QSM images. Bright veins in the susceptibility maps are vectorized and used to form a three-dimensional vascular mesh, or venogram, along which to display SvO2 values from QSM. Results Quantitative oxygenation venograms that map SvO2 along brain vessels of arbitrary orientation and geometry are shown in vivo. SvO2 values in major cerebral veins lie within the normal physiological range reported by 15O positron emission tomography. SvO2 from QSM is consistent with previous MR susceptometry methods for vessel segments oriented parallel to the main magnetic field. In vessel simulations, ℓ1 regularization results in less than 10% SvO2 absolute error across all vessel tilt orientations and provides more accurate SvO2 estimation than ℓ2 regularization. Conclusion The proposed analysis of susceptibility images enables reliable mapping of quantitative SvO2 along venograms and may facilitate clinical use of venous oxygenation imaging. PMID:24006229

  10. Quantitative 3D electromagnetic field determination of 1D nanostructures from single projection

    DOE PAGES

    Phatak, C.; Knoop, L. de; Houdellier, F.; ...

    2016-05-01

    One-dimensional (1D) nanostructures have been regarded as the most promising building blocks for nanoelectronics and nanocomposite material systems as well as for alternative energy applications. Although they result in confinement of a material, their properties and interactions with other nanostructures are still very much three-dimensional (3D) in nature. In this work, we present a novel method for quantitative determination of the 3D electromagnetic fields in and around 1D nanostructures using a single electron wave phase image, thereby eliminating the cumbersome acquisition of tomographic data. Using symmetry arguments, we have reconstructed the 3D magnetic field of a nickel nanowire as wellmore » as the 3D electric field around a carbon nanotube field emitter, from one single projection. The accuracy of quantitative values determined here is shown to be a better fit to the physics at play than the value obtained by conventional analysis. Moreover the 3D reconstructions can then directly be visualized and used in the design of functional 3D architectures built using 1D nanostructures.« less

  11. Quantitative 3D electromagnetic field determination of 1D nanostructures from single projection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phatak, C.; Knoop, L. de; Houdellier, F.

    One-dimensional (1D) nanostructures have been regarded as the most promising building blocks for nanoelectronics and nanocomposite material systems as well as for alternative energy applications. Although they result in confinement of a material, their properties and interactions with other nanostructures are still very much three-dimensional (3D) in nature. In this work, we present a novel method for quantitative determination of the 3D electromagnetic fields in and around 1D nanostructures using a single electron wave phase image, thereby eliminating the cumbersome acquisition of tomographic data. Using symmetry arguments, we have reconstructed the 3D magnetic field of a nickel nanowire as wellmore » as the 3D electric field around a carbon nanotube field emitter, from one single projection. The accuracy of quantitative values determined here is shown to be a better fit to the physics at play than the value obtained by conventional analysis. Moreover the 3D reconstructions can then directly be visualized and used in the design of functional 3D architectures built using 1D nanostructures.« less

  12. [Value of quantitative iodine-based material decomposition images with gemstone spectral CT imaging in the follow-up of patients with hepatocellular carcinoma after TACE treatment].

    PubMed

    Xing, Gusheng; Wang, Shuang; Li, Chenrui; Zhao, Xinming; Zhou, Chunwu

    2015-03-01

    To investigate the value of quantitative iodine-based material decomposition images with gemstone spectral CT imaging in the follow-up of patients with hepatocellular carcinoma (HCC) after transcatheter arterial chemoebolization (TACE). Consecutive 32 HCC patients with previous TACE treatment were included in this study. For the follow-up, arterial phase (AP) and venous phase (VP) dual-phase CT scans were performed with a single-source dual-energy CT scanner (Discovery CT 750HD, GE Healthcare). Iodine concentrations were derived from iodine-based material-decomposition images in the liver parenchyma, tumors and coagulation necrosis (CN) areas. The iodine concentration difference (ICD) between the arterial-phase (AP) and venal-phase (VP) were quantitatively evaluated in different tissues.The lesion-to-normal parenchyma iodine concentration ratio (LNR) was calculated. ROC analysis was performed for the qualitative evaluation, and the area under ROC (Az) was calculated to represent the diagnostic ability of ICD and LNR. In all the 32 HCC patients, the region of interesting (ROI) for iodine concentrations included liver parenchyma (n=42), tumors (n=28) and coagulation necrosis (n=24). During the AP the iodine concentration of CNs (median value 0.088 µg/mm(3)) appeared significantly higher than that of the tumors (0.064 µg/mm(3), P=0.022) and liver parenchyma (0.048 µg/mm(3), P=0.005). But it showed no significant difference between liver parenchyma and tumors (P=0.454). During the VP the iodine concentration in hepatic parenchyma (median value 0.181 µg/mm(3)) was significantly higher than that in CNs (0.140 µg/mm(3), P=0.042). There was no significant difference between liver parenchyma and tumors, CNs and tumors (both P>0.05). The median value of ICD in CNs was 0.006 µg/mm(3), significantly lower than that of the HCC (0.201 µg/mm(3), P<0.001) and hepatic parenchyma (0.117 µg/mm(3), P<0.001). The ICDs in tumors and hepatic parenchyma showed no significant

  13. Quantitative Decision Making.

    ERIC Educational Resources Information Center

    Baldwin, Grover H.

    The use of quantitative decision making tools provides the decision maker with a range of alternatives among which to decide, permits acceptance and use of the optimal solution, and decreases risk. Training line administrators in the use of these tools can help school business officials obtain reliable information upon which to base district…

  14. Accounting for the Multiple Natures of Missing Values in Label-Free Quantitative Proteomics Data Sets to Compare Imputation Strategies.

    PubMed

    Lazar, Cosmin; Gatto, Laurent; Ferro, Myriam; Bruley, Christophe; Burger, Thomas

    2016-04-01

    Missing values are a genuine issue in label-free quantitative proteomics. Recent works have surveyed the different statistical methods to conduct imputation and have compared them on real or simulated data sets and recommended a list of missing value imputation methods for proteomics application. Although insightful, these comparisons do not account for two important facts: (i) depending on the proteomics data set, the missingness mechanism may be of different natures and (ii) each imputation method is devoted to a specific type of missingness mechanism. As a result, we believe that the question at stake is not to find the most accurate imputation method in general but instead the most appropriate one. We describe a series of comparisons that support our views: For instance, we show that a supposedly "under-performing" method (i.e., giving baseline average results), if applied at the "appropriate" time in the data-processing pipeline (before or after peptide aggregation) on a data set with the "appropriate" nature of missing values, can outperform a blindly applied, supposedly "better-performing" method (i.e., the reference method from the state-of-the-art). This leads us to formulate few practical guidelines regarding the choice and the application of an imputation method in a proteomics context.

  15. Value of Quantitative Three-dimensional Doppler Ultrasound in the Differentiation of Benign and Malignant Thyroid Nodules.

    PubMed

    Li, Wen-Bo; Zhang, Bo; Jiang, Yu-Xin; Zhu, Qing-Li; Zhang, Qing; Sun, Jian

    2015-06-01

    To investigate the role of quantitative three-dimensional (3D) power Doppler ultrasound in differentiating malignant and benign thyroid nodule. A total of 92 lesions in 86 patients were preoperatively examined using 3D power Doppler ultrasound. The Virtual Organ Computer-aided Analysis(VOCAL)-imaging program was used to analyze the stored volume ultrasound. The differences in the mean gray value (MG), vascularization index (VI), flow index(FI), and vascularization flow index (VFI) were compared between benign and malignant lesions. The MG of the malignant thyroid nodules was significantly lower than that of the benign ones (28.27±7.21 vs. 32.89±8.73,P=0.007). The benign nodules had significantly higher VI,FI,and VFI than the malignant nodules [VI:(40.43±26.55)% vs. (26.87±23.06)%,P=0.011;FI:41.03±7.19 vs. 37.51±7.17,P=0.022;VFI:18.23±14.60 vs. 11.47±12.47, P=0.009]. Also,76.5% (39/51) of the malignant nodules and 92.7% (38/41) of the benign nodules had higher VIs in the shell of the lesion than that of the whole lesion,and 80.4%(41/51) of the malignant nodules and 95.1% (39/41) of the benign nodules had higher FIs in the shell of the lesion than that of the whole lesion. Quantitative 3D power Doppler ultrasound provides a useful tool in distinguishing benign and malignant thyroid nodules. The malignant thyroid nodules have lower echoes than the benign nodules, wherese the benign nodules have larger blood flow than the malignant nodules.

  16. Predicting quantitative and qualitative values of recreation participation

    Treesearch

    Elwood L., Jr. Shafer; George Moeller

    1971-01-01

    If future recreation consumption and associated intangible values can be predicted, the problem of rapid decision making in recreation-resource management can be reduced, and the problems of implementing those decisions can be anticipated. Management and research responsibilities for meeting recreation demand are discussed, and proved methods for forecasting recreation...

  17. Bilateral cartilage T2 mapping 9 years after Mega-OATS implantation at the knee: a quantitative 3T MRI study.

    PubMed

    Jungmann, P M; Brucker, P U; Baum, T; Link, T M; Foerschner, F; Minzlaff, P; Banke, I J; Saier, T; Imhoff, A B; Rummeny, E J; Bauer, J S

    2015-12-01

    To evaluate morphological and quantitative MR findings 9 years after autograft transfer of the posterior femoral condyle (Mega-OATS) and to correlate these findings with clinical outcomes. Quantitative MR measurements were also obtained of the contralateral knee and the utility as reference standard was investigated. Both knees of 20 patients with Mega-OATS osteochondral repair at the medial femoral condyle (MFC) were studied using 3T MRI 9 years after the procedure. MR-sequences included morphological sequences and a 2D multislice multiecho (MSME) spin echo (SE) sequence for quantitative cartilage T2 mapping. Cartilage segmentation was performed at the cartilage repair site and six additional knee compartments. Semi-quantitative MR observation of cartilage repair tissue (MOCART) scores and clinical Lysholm scores were obtained. Paired t-tests and Spearman correlations were used for statistical analysis. Global T2-values were significantly higher at ipsilateral knees compared to contralateral knees (42.1 ± 3.0 ms vs 40.4 ± 2.6 ms, P = 0.018). T2-values of the Mega-OATS site correlated significantly with MOCART scores (R = -0.64, P = 0.006). The correlations between MOCART and Lysholm scores and between absolute T2-values and Lysholm scores were not significant (P > 0.05). However, higher T2 side-to-side differences at the femoral condyles correlated significantly with more severe clinical symptoms (medial, R = -0.53, P = 0.030; lateral, R = -0.51, P = 0.038). Despite long-term survival, 9 years after Mega-OATS procedures, T2-values of the grafts were increased compared to contralateral knees. Clinical scores correlated best with T2 side-to-side differences of the femoral condyles, indicating that intraindividual adjustment may be beneficial for outcome evaluation. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. Quantitative breast tissue characterization using grating-based x-ray phase-contrast imaging

    NASA Astrophysics Data System (ADS)

    Willner, M.; Herzen, J.; Grandl, S.; Auweter, S.; Mayr, D.; Hipp, A.; Chabior, M.; Sarapata, A.; Achterhold, K.; Zanette, I.; Weitkamp, T.; Sztrókay, A.; Hellerhoff, K.; Reiser, M.; Pfeiffer, F.

    2014-04-01

    X-ray phase-contrast imaging has received growing interest in recent years due to its high capability in visualizing soft tissue. Breast imaging became the focus of particular attention as it is considered the most promising candidate for a first clinical application of this contrast modality. In this study, we investigate quantitative breast tissue characterization using grating-based phase-contrast computed tomography (CT) at conventional polychromatic x-ray sources. Different breast specimens have been scanned at a laboratory phase-contrast imaging setup and were correlated to histopathology. Ascertained tumor types include phylloides tumor, fibroadenoma and infiltrating lobular carcinoma. Identified tissue types comprising adipose, fibroglandular and tumor tissue have been analyzed in terms of phase-contrast Hounsfield units and are compared to high-quality, high-resolution data obtained with monochromatic synchrotron radiation, as well as calculated values based on tabulated tissue properties. The results give a good impression of the method’s prospects and limitations for potential tumor detection and the associated demands on such a phase-contrast breast CT system. Furthermore, the evaluated quantitative tissue values serve as a reference for simulations and the design of dedicated phantoms for phase-contrast mammography.

  19. Evaluation of a rapid quantitative determination method of PSA concentration with gold immunochromatographic strips.

    PubMed

    Wu, Cheng-Ching; Lin, Hung-Yu; Wang, Chao-Ping; Lu, Li-Fen; Yu, Teng-Hung; Hung, Wei-Chin; Houng, Jer-Yiing; Chung, Fu-Mei; Lee, Yau-Jiunn; Hu, Jin-Jia

    2015-11-03

    Prostate cancer remains the most common cancer in men. Qualitative or semi-quantitative immunochromatographic measurements of prostate specific antigen (PSA) have been shown to be simple, noninvasive and feasible. The aim of this study was to evaluate an optimized gold immunochromatographic strip device for the detection of PSA, in which the results can be analysed using a Chromogenic Rapid Test Reader to quantitatively assess the test results. This reader measures the reflectance of the signal line via a charge-coupled device camera. For quantitative analysis, PSA concentration was computed via a calibration equation. Capillary blood samples from 305 men were evaluated, and two independent observers interpreted the test results after 12 min. Blood samples were also collected and tested with a conventional quantitative assay. Sensitivity, specificity, positive and negative predictive values, and accuracy of the PSA rapid quantitative test system were 100, 96.6, 89.5, 100, and 97.4 %, respectively. Reproducibility of the test was 99.2, and interobserver variation was 8 % with a false positive rate of 3.4 %. The correlation coefficient between the ordinary quantitative assay and the rapid quantitative test was 0.960. The PSA rapid quantitative test system provided results quickly and was easy to use, so that tests using this system can be easily performed at outpatient clinics or elsewhere. This system may also be useful for initial cancer screening and for point-of-care testing, because results can be obtained within 12 min and at a cost lower than that of conventional quantitative assays.

  20. Quantitative microbiological risk assessment as a tool to obtain useful information for risk managers--specific application to Listeria monocytogenes and ready-to-eat meat products.

    PubMed

    Mataragas, M; Zwietering, M H; Skandamis, P N; Drosinos, E H

    2010-07-31

    The presence of Listeria monocytogenes in a sliced cooked, cured ham-like meat product was quantitatively assessed. Sliced cooked, cured meat products are considered as high risk products. These ready-to-eat, RTE, products (no special preparation, e.g. thermal treatment, before eating is required), support growth of pathogens (high initial pH=6.2-6.4 and water activity=0.98-0.99) and has a relatively long period of storage at chilled temperatures with a shelf life equal to 60 days based on manufacturer's instructions. Therefore, in case of post-process contamination, even with low number of cells, the microorganism is able to reach unacceptable levels at the time of consumption. The aim of this study was to conduct a Quantitative Microbiological Risk Assessment (QMRA) on the risk of L. monocytogenes presence in RTE meat products. This may help risk managers to make decisions and apply control measures with ultimate objective the food safety assurance. Examples are given to illustrate the development of practical risk management strategies based on the results obtained from the QMRA model specifically developed for this pathogen/food product combination. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Quantitative T2 Magnetic Resonance Imaging Compared to Morphological Grading of the Early Cervical Intervertebral Disc Degeneration: An Evaluation Approach in Asymptomatic Young Adults

    PubMed Central

    Han, Zhihua; Shao, Lixin; Xie, Yan; Wu, Jianhong; Zhang, Yan; Xin, Hongkui; Ren, Aijun; Guo, Yong; Wang, Deli; He, Qing; Ruan, Dike

    2014-01-01

    Objective The objective of this study was to evaluate the efficacy of quantitative T2 magnetic resonance imaging (MRI) for quantifying early cervical intervertebral disc (IVD) degeneration in asymptomatic young adults by correlating the T2 value with Pfirrmann grade, sex, and anatomic level. Methods Seventy asymptomatic young subjects (34 men and 36 women; mean age, 22.80±2.11 yr; range, 18–25 years) underwent 3.0-T MRI to obtain morphological data (one T1-fast spin echo (FSE) and three-plane T2-FSE, used to assign a Pfirrmann grade (I–V)) and for T2 mapping (multi-echo spin echo). T2 values in the nucleus pulposus (NP, n = 350) and anulus fibrosus (AF, n = 700) were obtained. Differences in T2 values between sexes and anatomic level were evaluated, and linear correlation analysis of T2 values versus degenerative grade was conducted. Findings Cervical IVDs of healthy young adults were commonly determined to be at Pfirrmann grades I and II. T2 values of NPs were significantly higher than those of AF at all anatomic levels (P<0.000). The NP, anterior AF and posterior AF values did not differ significantly between genders at the same anatomic level (P>0.05). T2 values decreased linearly with degenerative grade. Linear correlation analysis revealed a strong negative association between the Pfirrmann grade and the T2 values of the NP (P = 0.000) but not the T2 values of the AF (P = 0.854). However, non-degenerated discs (Pfirrmann grades I and II) showed a wide range of T2 relaxation time. T2 values according to disc degeneration level classification were as follows: grade I (>62.03 ms), grade II (54.60–62.03 ms), grade III (<54.60 ms). Conclusions T2 quantitation provides a more sensitive and robust approach for detecting and characterizing the early stage of cervical IVD degeneration and to create a reliable quantitative in healthy young adults. PMID:24498384

  2. Quantitative T2 magnetic resonance imaging compared to morphological grading of the early cervical intervertebral disc degeneration: an evaluation approach in asymptomatic young adults.

    PubMed

    Chen, Chun; Huang, Minghua; Han, Zhihua; Shao, Lixin; Xie, Yan; Wu, Jianhong; Zhang, Yan; Xin, Hongkui; Ren, Aijun; Guo, Yong; Wang, Deli; He, Qing; Ruan, Dike

    2014-01-01

    The objective of this study was to evaluate the efficacy of quantitative T2 magnetic resonance imaging (MRI) for quantifying early cervical intervertebral disc (IVD) degeneration in asymptomatic young adults by correlating the T2 value with Pfirrmann grade, sex, and anatomic level. Seventy asymptomatic young subjects (34 men and 36 women; mean age, 22.80±2.11 yr; range, 18-25 years) underwent 3.0-T MRI to obtain morphological data (one T1-fast spin echo (FSE) and three-plane T2-FSE, used to assign a Pfirrmann grade (I-V)) and for T2 mapping (multi-echo spin echo). T2 values in the nucleus pulposus (NP, n = 350) and anulus fibrosus (AF, n = 700) were obtained. Differences in T2 values between sexes and anatomic level were evaluated, and linear correlation analysis of T2 values versus degenerative grade was conducted. Cervical IVDs of healthy young adults were commonly determined to be at Pfirrmann grades I and II. T2 values of NPs were significantly higher than those of AF at all anatomic levels (P<0.000). The NP, anterior AF and posterior AF values did not differ significantly between genders at the same anatomic level (P>0.05). T2 values decreased linearly with degenerative grade. Linear correlation analysis revealed a strong negative association between the Pfirrmann grade and the T2 values of the NP (P = 0.000) but not the T2 values of the AF (P = 0.854). However, non-degenerated discs (Pfirrmann grades I and II) showed a wide range of T2 relaxation time. T2 values according to disc degeneration level classification were as follows: grade I (>62.03 ms), grade II (54.60-62.03 ms), grade III (<54.60 ms). T2 quantitation provides a more sensitive and robust approach for detecting and characterizing the early stage of cervical IVD degeneration and to create a reliable quantitative in healthy young adults.

  3. [Effect of non-genetically modified (non-GM) soy varieties on the measured value of GM soy by a quantitative PCR method].

    PubMed

    Watanabe, Takahiro; Sekino, Ayako; Shiramasa, Yuko; Matsuda, Rieko; Maitani, Tamio

    2008-08-01

    It is very important to examine the effect of non-genetically modified (non-GM) soy varieties, which constitute the matrix of the testing sample used to quantify GM soy (RRS), on the measured value of RRS by quantitative PCR methods. Therefore, we quantified the amount of RRS in powder-mixed samples containing 1 or 5% RRS prepared by using 10 different varieties of non-GM soy as the matrix. The results revealed that the measured values were not in agreement with the powder-mixing levels and that the extent of the difference depended on the variety of non-GM soy used as the matrix. The yields of DNA extracted differed among the soy varieties. On the other hand, analysis of DNA-mixed samples, that were prepared with the DNAs extracted from RRS and non-GM soy varieties, showed that the measured values of RRS were in agreement with the DNA-mixing levels. These results strongly suggest that the proportions of DNA derived from RRS and non-GM soy were not consistent with the powder-mixing ratio in the case of some non-GM soy varieties used as a matrix, resulting in the discrepancy between the measured values and the powder-mixing levels.

  4. A Quantitative Comparison of Single-Dye Tracking Analysis Tools Using Monte Carlo Simulations

    PubMed Central

    McColl, James; Irvine, Kate L.; Davis, Simon J.; Gay, Nicholas J.; Bryant, Clare E.; Klenerman, David

    2013-01-01

    Single-particle tracking (SPT) is widely used to study processes from membrane receptor organization to the dynamics of RNAs in living cells. While single-dye labeling strategies have the benefit of being minimally invasive, this comes at the expense of data quality; typically a data set of short trajectories is obtained and analyzed by means of the mean square displacements (MSD) or the distribution of the particles’ displacements in a set time interval (jump distance, JD). To evaluate the applicability of both approaches, a quantitative comparison of both methods under typically encountered experimental conditions is necessary. Here we use Monte Carlo simulations to systematically compare the accuracy of diffusion coefficients (D-values) obtained for three cases: one population of diffusing species, two populations with different D-values, and a population switching between two D-values. For the first case we find that the MSD gives more or equally accurate results than the JD analysis (relative errors of D-values <6%). If two diffusing species are present or a particle undergoes a motion change, the JD analysis successfully distinguishes both species (relative error <5%). Finally we apply the JD analysis to investigate the motion of endogenous LPS receptors in live macrophages before and after treatment with methyl-β-cyclodextrin and latrunculin B. PMID:23737978

  5. A quantitative comparison of single-dye tracking analysis tools using Monte Carlo simulations.

    PubMed

    Weimann, Laura; Ganzinger, Kristina A; McColl, James; Irvine, Kate L; Davis, Simon J; Gay, Nicholas J; Bryant, Clare E; Klenerman, David

    2013-01-01

    Single-particle tracking (SPT) is widely used to study processes from membrane receptor organization to the dynamics of RNAs in living cells. While single-dye labeling strategies have the benefit of being minimally invasive, this comes at the expense of data quality; typically a data set of short trajectories is obtained and analyzed by means of the mean square displacements (MSD) or the distribution of the particles' displacements in a set time interval (jump distance, JD). To evaluate the applicability of both approaches, a quantitative comparison of both methods under typically encountered experimental conditions is necessary. Here we use Monte Carlo simulations to systematically compare the accuracy of diffusion coefficients (D-values) obtained for three cases: one population of diffusing species, two populations with different D-values, and a population switching between two D-values. For the first case we find that the MSD gives more or equally accurate results than the JD analysis (relative errors of D-values <6%). If two diffusing species are present or a particle undergoes a motion change, the JD analysis successfully distinguishes both species (relative error <5%). Finally we apply the JD analysis to investigate the motion of endogenous LPS receptors in live macrophages before and after treatment with methyl-β-cyclodextrin and latrunculin B.

  6. Diagnostic value of quantitative contrast-enhanced ultrasound (CEUS) for early detection of renal hyperperfusion in diabetic kidney disease.

    PubMed

    Wang, Ling; Wu, Jian; Cheng, Jia-Fen; Liu, Xin-Ying; Ma, Fang; Guo, Le-Hang; Xu, Jun-Mei; Wu, Tianfu; Mohan, Chandra; Peng, Ai; Xu, Hui-Xiong; Song, Ya-Xiang

    2015-12-01

    To investigate the diagnostic value of quantitative contrast-enhanced ultrasound (CEUS) for early detection of renal hyperperfusion in diabetic kidney disease (DKD). 55 DKD patients with estimated glomerular filtration rate (eGFR) >30 ml/min/1.73 m(2) and 26 normal controls (NCs) were enrolled. Clinical data was well documented. Blood samples were drawn for evaluation of renal function including blood urea nitrogen (BUN), serum creatinine (SCr) and serum uric acid (SUA), and urine samples were assayed for total protein quantification, and various microprotein markers. According to eGFR level, DKD patients were divided into early-stage DKD (eGFR ≥90 ml/min/1.73 m(2), n = 18) and middle-stage DKD (eGFR 30-90 ml/min/1.73 m(2), n = 37). Based on urinary microalbumin/creatinine ratio (MALB/UCR), early-stage DKD patients were further classified into two groups: MALB/UCR <10 g/mol (n = 11) and MALB/UCR ≥10 g/mol (n = 7). Then, CEUS was performed to observe the real-time renal perfusion, and low acoustic power contrast-specific imaging was used for quantitative analysis. The renal perfusion images of CEUS were well developed successively. The corresponding perfusion curves based on echo-power signals in time series were constructed. Quantitative analysis showed that area under the descending curve (AUC2) was significantly increased in early-stage DKD compared to middle-stage DKD (p < 0.05), but AUC showed no significant difference. Further comparison between different MALB/UCR levels of early-stage DKD showed that patients with MALB/UCR ≥10 g/mol had significantly increased levels of AUC, AUC2 and proteinuria than patients with low MALB/UCR (p < 0.05). Also, high MALB/UCR DKD patients had increased proteinuria but similar eGFR compared to low MALB/UCR patients. Renal microvascular hyperperfusion may be responsible for overt proteinuria until decline of renal filtration in DKD. AUC2 could be an early and sensitive marker for early renal injury and renal microvascular

  7. Quantitative determination of amorphous cyclosporine in crystalline cyclosporine samples by Fourier transform infrared spectroscopy.

    PubMed

    Bertacche, Vittorio; Pini, Elena; Stradi, Riccardo; Stratta, Fabio

    2006-01-01

    The purpose of this study is the development of a quantification method to detect the amount of amorphous cyclosporine using Fourier transform infrared (FTIR) spectroscopy. The mixing of different percentages of crystalline cyclosporine with amorphous cyclosporine was used to obtain a set of standards, composed of cyclosporine samples characterized by different percentages of amorphous cyclosporine. Using a wavelength range of 450-4,000 cm(-1), FTIR spectra were obtained from samples in potassium bromide pellets and then a partial least squares (PLS) model was exploited to correlate the features of the FTIR spectra with the percentage of amorphous cyclosporine in the samples. This model gave a standard error of estimate (SEE) of 0.3562, with an r value of 0.9971 and a standard error of prediction (SEP) of 0.4168, which derives from the cross validation function used to check the precision of the model. Statistical values reveal the applicability of the method to the quantitative determination of amorphous cyclosporine in crystalline cyclosporine samples.

  8. Quantitative determination of testosterone levels with biolayer interferometry.

    PubMed

    Zhang, Hao; Li, Wei; Luo, Hong; Xiong, Guangming; Yu, Yuanhua

    2017-10-01

    Natural and synthetic steroid hormones are widely spread in the environment and are considered as pollutants due to their endocrine activities, even at low concentrations, which are harmful to human health. To detect steroid hormones in the environment, a novel biosensor system was developed based on the principle of biolayer interferometry. Detection is based on changes in the interference pattern of white light reflected from the surface of an optical fiber with bound biomolecules. Monitoring interactions between molecules does not require radioactive, enzymatic, or fluorescent labels. Here, 2 double-stranded DNA fragments of operator 1 (OP1) and OP2 containing 10-bp palindromic sequences in chromosomal Comamonas testosteroni DNA (ATCC11996) were surface-immobilized to streptavidin sensors. Interference changes were detected when repressor protein RepA bound the DNA sequences. DNA-protein interactions were characterized and kinetic parameters were obtained. The dissociation constants between the OP1 and OP2 DNA sequences and RepA were 9.865 × 10 -9  M and 2.750 × 10 -8  M, respectively. The reactions showed high specifically and affinity. Because binding of the 10-bp palindromic sequence and RepA was affected by RepA-testosterone binding, the steroid could be quantitatively determined rapidly using the biosensor system. The mechanism of the binding assay was as follows. RepA could bind both OP1 and testosterone. RepA binding to testosterone changed the protein conformation, which influenced the binding between RepA and OP1. The percentage of the signal detected negative correlation with the testosterone concentration. A standard curve was obtained, and the correlation coefficient value was approximately 0.97. We could quantitatively determine testosterone levels between 2.13 and 136.63 ng/ml. Each sample could be quantitatively detected in 17 min. These results suggested that the specific interaction between double-stranded OP1 DNA and the RepA protein

  9. Quantitative Literacy: Geosciences and Beyond

    NASA Astrophysics Data System (ADS)

    Richardson, R. M.; McCallum, W. G.

    2002-12-01

    Quantitative literacy seems like such a natural for the geosciences, right? The field has gone from its origin as a largely descriptive discipline to one where it is hard to imagine failing to bring a full range of mathematical tools to the solution of geological problems. Although there are many definitions of quantitative literacy, we have proposed one that is analogous to the UNESCO definition of conventional literacy: "A quantitatively literate person is one who, with understanding, can both read and represent quantitative information arising in his or her everyday life." Central to this definition is the concept that a curriculum for quantitative literacy must go beyond the basic ability to "read and write" mathematics and develop conceptual understanding. It is also critical that a curriculum for quantitative literacy be engaged with a context, be it everyday life, humanities, geoscience or other sciences, business, engineering, or technology. Thus, our definition works both within and outside the sciences. What role do geoscience faculty have in helping students become quantitatively literate? Is it our role, or that of the mathematicians? How does quantitative literacy vary between different scientific and engineering fields? Or between science and nonscience fields? We will argue that successful quantitative literacy curricula must be an across-the-curriculum responsibility. We will share examples of how quantitative literacy can be developed within a geoscience curriculum, beginning with introductory classes for nonmajors (using the Mauna Loa CO2 data set) through graduate courses in inverse theory (using singular value decomposition). We will highlight six approaches to across-the curriculum efforts from national models: collaboration between mathematics and other faculty; gateway testing; intensive instructional support; workshops for nonmathematics faculty; quantitative reasoning requirement; and individual initiative by nonmathematics faculty.

  10. Quantitative DIC microscopy using an off-axis self-interference approach.

    PubMed

    Fu, Dan; Oh, Seungeun; Choi, Wonshik; Yamauchi, Toyohiko; Dorn, August; Yaqoob, Zahid; Dasari, Ramachandra R; Feld, Michael S

    2010-07-15

    Traditional Normarski differential interference contrast (DIC) microscopy is a very powerful method for imaging nonstained biological samples. However, one of its major limitations is the nonquantitative nature of the imaging. To overcome this problem, we developed a quantitative DIC microscopy method based on off-axis sample self-interference. The digital holography algorithm is applied to obtain quantitative phase gradients in orthogonal directions, which leads to a quantitative phase image through a spiral integration of the phase gradients. This method is practically simple to implement on any standard microscope without stringent requirements on polarization optics. Optical sectioning can be obtained through enlarged illumination NA.

  11. Hydrocarbon saturation determination using acoustic velocities obtained through casing

    DOEpatents

    Moos, Daniel

    2010-03-09

    Compressional and shear velocities of earth formations are measured through casing. The determined compressional and shear velocities are used in a two component mixing model to provides improved quantitative values for the solid, the dry frame, and the pore compressibility. These are used in determination of hydrocarbon saturation.

  12. A novel multi-walled carbon nanotube-based antibody conjugate for quantitative and semi-quantitative lateral flow assays.

    PubMed

    Sun, Wenjuan; Hu, Xiaolong; Liu, Jia; Zhang, Yurong; Lu, Jianzhong; Zeng, Libo

    2017-10-01

    In this study, the multi-walled carbon nanotubes (MWCNTs) were applied in lateral flow strips (LFS) for semi-quantitative and quantitative assays. Firstly, the solubility of MWCNTs was improved using various surfactants to enhance their biocompatibility for practical application. The dispersed MWCNTs were conjugated with the methamphetamine (MET) antibody in a non-covalent manner and then manufactured into the LFS for the quantitative detection of MET. The MWCNTs-based lateral flow assay (MWCNTs-LFA) exhibited an excellent linear relationship between the values of test line and MET when its concentration ranges from 62.5 to 1500 ng/mL. The sensitivity of the LFS was evaluated by conjugating MWCNTs with HCG antibody and the MWCNTs conjugated method is 10 times more sensitive than the one conjugated with classical colloidal gold nanoparticles. Taken together, our data demonstrate that MWCNTs-LFA is a more sensitive and reliable assay for semi-quantitative and quantitative detection which can be used in forensic analysis.

  13. Quantitative surface topography determination by Nomarski reflection microscopy. 2: Microscope modification, calibration, and planar sample experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartman, J.S.; Gordon, R.L.; Lessor, D.L.

    1980-09-01

    The application of reflective Nomarski differential interference contrast microscopy for the determination of quantitative sample topography data is presented. The discussion includes a review of key theoretical results presented previously plus the experimental implementation of the concepts using a commercial Momarski microscope. The experimental work included the modification and characterization of a commercial microscope to allow its use for obtaining quantitative sample topography data. System usage for the measurement of slopes on flat planar samples is also discussed. The discussion has been designed to provide the theoretical basis, a physical insight, and a cookbook procedure for implementation to allow thesemore » results to be of value to both those interested in the microscope theory and its practical usage in the metallography laboratory.« less

  14. Multisite concordance of apparent diffusion coefficient measurements across the NCI Quantitative Imaging Network.

    PubMed

    Newitt, David C; Malyarenko, Dariya; Chenevert, Thomas L; Quarles, C Chad; Bell, Laura; Fedorov, Andriy; Fennessy, Fiona; Jacobs, Michael A; Solaiyappan, Meiyappan; Hectors, Stefanie; Taouli, Bachir; Muzi, Mark; Kinahan, Paul E; Schmainda, Kathleen M; Prah, Melissa A; Taber, Erin N; Kroenke, Christopher; Huang, Wei; Arlinghaus, Lori R; Yankeelov, Thomas E; Cao, Yue; Aryal, Madhava; Yen, Yi-Fen; Kalpathy-Cramer, Jayashree; Shukla-Dave, Amita; Fung, Maggie; Liang, Jiachao; Boss, Michael; Hylton, Nola

    2018-01-01

    Diffusion weighted MRI has become ubiquitous in many areas of medicine, including cancer diagnosis and treatment response monitoring. Reproducibility of diffusion metrics is essential for their acceptance as quantitative biomarkers in these areas. We examined the variability in the apparent diffusion coefficient (ADC) obtained from both postprocessing software implementations utilized by the NCI Quantitative Imaging Network and online scan time-generated ADC maps. Phantom and in vivo breast studies were evaluated for two ([Formula: see text]) and four ([Formula: see text]) [Formula: see text]-value diffusion metrics. Concordance of the majority of implementations was excellent for both phantom ADC measures and in vivo [Formula: see text], with relative biases [Formula: see text] ([Formula: see text]) and [Formula: see text] (phantom [Formula: see text]) but with higher deviations in ADC at the lowest phantom ADC values. In vivo [Formula: see text] concordance was good, with typical biases of [Formula: see text] to 3% but higher for online maps. Multiple b -value ADC implementations were separated into two groups determined by the fitting algorithm. Intergroup mean ADC differences ranged from negligible for phantom data to 2.8% for [Formula: see text] in vivo data. Some higher deviations were found for individual implementations and online parametric maps. Despite generally good concordance, implementation biases in ADC measures are sometimes significant and may be large enough to be of concern in multisite studies.

  15. FAIR exempting separate T (1) measurement (FAIREST): a novel technique for online quantitative perfusion imaging and multi-contrast fMRI.

    PubMed

    Lai, S; Wang, J; Jahng, G H

    2001-01-01

    A new pulse sequence, dubbed FAIR exempting separate T(1) measurement (FAIREST) in which a slice-selective saturation recovery acquisition is added in addition to the standard FAIR (flow-sensitive alternating inversion recovery) scheme, was developed for quantitative perfusion imaging and multi-contrast fMRI. The technique allows for clean separation between and thus simultaneous assessment of BOLD and perfusion effects, whereas quantitative cerebral blood flow (CBF) and tissue T(1) values are monitored online. Online CBF maps were obtained using the FAIREST technique and the measured CBF values were consistent with the off-line CBF maps obtained from using the FAIR technique in combination with a separate sequence for T(1) measurement. Finger tapping activation studies were carried out to demonstrate the applicability of the FAIREST technique in a typical fMRI setting for multi-contrast fMRI. The relative CBF and BOLD changes induced by finger-tapping were 75.1 +/- 18.3 and 1.8 +/- 0.4%, respectively, and the relative oxygen consumption rate change was 2.5 +/- 7.7%. The results from correlation of the T(1) maps with the activation images on a pixel-by-pixel basis show that the mean T(1) value of the CBF activation pixels is close to the T(1) of gray matter while the mean T(1) value of the BOLD activation pixels is close to the T(1) range of blood and cerebrospinal fluid. Copyright 2001 John Wiley & Sons, Ltd.

  16. Quantitative analysis of eosinophil chemotaxis tracked using a novel optical device -- TAXIScan.

    PubMed

    Nitta, Nao; Tsuchiya, Tomoko; Yamauchi, Akira; Tamatani, Takuya; Kanegasaki, Shiro

    2007-03-30

    We have reported previously the development of an optically accessible, horizontal chemotaxis apparatus, in which migration of cells in the channel from a start line can be traced with time-lapse intervals using a CCD camera (JIM 282, 1-11, 2003). To obtain statistical data of migrating cells, we have developed quantitative methods to calculate various parameters in the process of chemotaxis, employing human eosinophil and CXCL12 as a model cell and a model chemoattractant, respectively. Median values of velocity and directionality of each cell within an experimental period could be calculated from the migratory pathway data obtained from time-lapse images and the data were expressed as Velocity-Directionality (VD) plot. This plot is useful for quantitatively analyzing multiple migrating cells exposed to a certain chemoattractant, and can distinguish chemotaxis from random migration. Moreover precise observation of cell migration revealed that each cell had a different lag period before starting chemotaxis, indicating variation in cell sensitivity to the chemoattractant. Thus lag time of each cell before migration, and time course of increment of the migrating cell ratio at the early stages could be calculated. We also graphed decrement of still moving cell ratio at the later stages by calculating the duration time of cell migration of each cell. These graphs could distinguish different motion patterns of chemotaxis of eosinophils, in response to a range of chemoattractants; PGD(2), fMLP, CCL3, CCL5 and CXCL12. Finally, we compared parameters of eosinophils from normal volunteers, allergy patients and asthma patients and found significant difference in response to PGD(2). The quantitative methods described here could be applicable to image data obtained with any combination of cells and chemoattractants and useful not only for basic studies of chemotaxis but also for diagnosis and for drug screening.

  17. Obtaining value prior to pulping with diethyl oxalate and oxalic acid

    Treesearch

    W.R. Kenealy; E. Horn; C.J. Houtman; J. Laplaza; T.W. Jeffries

    2007-01-01

    Pulp and paper are converted to paper products with yields of paper dependent on the wood and the process used. Even with high yield pulps there are conversion losses and with chemical pulps the yields approach 50%. The portions of the wood that do not provide product are either combusted to generate power and steam or incur a cost in waste water treatment. Value prior...

  18. Cerebral Blood Volume ASPECTS Is the Best Predictor of Clinical Outcome in Acute Ischemic Stroke: A Retrospective, Combined Semi-Quantitative and Quantitative Assessment.

    PubMed

    Padroni, Marina; Bernardoni, Andrea; Tamborino, Carmine; Roversi, Gloria; Borrelli, Massimo; Saletti, Andrea; De Vito, Alessandro; Azzini, Cristiano; Borgatti, Luca; Marcello, Onofrio; d'Esterre, Christopher; Ceruti, Stefano; Casetta, Ilaria; Lee, Ting-Yim; Fainardi, Enrico

    2016-01-01

    The capability of CT perfusion (CTP) Alberta Stroke Program Early CT Score (ASPECTS) to predict outcome and identify ischemia severity in acute ischemic stroke (AIS) patients is still questioned. 62 patients with AIS were imaged within 8 hours of symptom onset by non-contrast CT, CT angiography and CTP scans at admission and 24 hours. CTP ASPECTS was calculated on the affected hemisphere using cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) maps by subtracting 1 point for any abnormalities visually detected or measured within multiple cortical circular regions of interest according to previously established thresholds. MTT-CBV ASPECTS was considered as CTP ASPECTS mismatch. Hemorrhagic transformation (HT), recanalization status and reperfusion grade at 24 hours, final infarct volume at 7 days and modified Rankin scale (mRS) at 3 months after onset were recorded. Semi-quantitative and quantitative CTP ASPECTS were highly correlated (p<0.00001). CBF, CBV and MTT ASPECTS were higher in patients with no HT and mRS ≤ 2 and inversely associated with final infarct volume and mRS (p values: from p<0.05 to p<0.00001). CTP ASPECTS mismatch was slightly associated with radiological and clinical outcomes (p values: from p<0.05 to p<0.02) only if evaluated quantitatively. A CBV ASPECTS of 9 was the optimal semi-quantitative value for predicting outcome. Our findings suggest that visual inspection of CTP ASPECTS recognizes infarct and ischemic absolute values. Semi-quantitative CBV ASPECTS, but not CTP ASPECTS mismatch, represents a strong prognostic indicator, implying that core extent is the main determinant of outcome, irrespective of penumbra size.

  19. Cerebral Blood Volume ASPECTS Is the Best Predictor of Clinical Outcome in Acute Ischemic Stroke: A Retrospective, Combined Semi-Quantitative and Quantitative Assessment

    PubMed Central

    Padroni, Marina; Bernardoni, Andrea; Tamborino, Carmine; Roversi, Gloria; Borrelli, Massimo; Saletti, Andrea; De Vito, Alessandro; Azzini, Cristiano; Borgatti, Luca; Marcello, Onofrio; d’Esterre, Christopher; Ceruti, Stefano; Casetta, Ilaria; Lee, Ting-Yim; Fainardi, Enrico

    2016-01-01

    Introduction The capability of CT perfusion (CTP) Alberta Stroke Program Early CT Score (ASPECTS) to predict outcome and identify ischemia severity in acute ischemic stroke (AIS) patients is still questioned. Methods 62 patients with AIS were imaged within 8 hours of symptom onset by non-contrast CT, CT angiography and CTP scans at admission and 24 hours. CTP ASPECTS was calculated on the affected hemisphere using cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) maps by subtracting 1 point for any abnormalities visually detected or measured within multiple cortical circular regions of interest according to previously established thresholds. MTT-CBV ASPECTS was considered as CTP ASPECTS mismatch. Hemorrhagic transformation (HT), recanalization status and reperfusion grade at 24 hours, final infarct volume at 7 days and modified Rankin scale (mRS) at 3 months after onset were recorded. Results Semi-quantitative and quantitative CTP ASPECTS were highly correlated (p<0.00001). CBF, CBV and MTT ASPECTS were higher in patients with no HT and mRS≤2 and inversely associated with final infarct volume and mRS (p values: from p<0.05 to p<0.00001). CTP ASPECTS mismatch was slightly associated with radiological and clinical outcomes (p values: from p<0.05 to p<0.02) only if evaluated quantitatively. A CBV ASPECTS of 9 was the optimal semi-quantitative value for predicting outcome. Conclusions Our findings suggest that visual inspection of CTP ASPECTS recognizes infarct and ischemic absolute values. Semi-quantitative CBV ASPECTS, but not CTP ASPECTS mismatch, represents a strong prognostic indicator, implying that core extent is the main determinant of outcome, irrespective of penumbra size. PMID:26824672

  20. Quantitative study of FORC diagrams in thermally corrected Stoner- Wohlfarth nanoparticles systems

    NASA Astrophysics Data System (ADS)

    De Biasi, E.; Curiale, J.; Zysler, R. D.

    2016-12-01

    The use of FORC diagrams is becoming increasingly popular among researchers devoted to magnetism and magnetic materials. However, a thorough interpretation of this kind of diagrams, in order to achieve quantitative information, requires an appropriate model of the studied system. For that reason most of the FORC studies are used for a qualitative analysis. In magnetic systems thermal fluctuations "blur" the signatures of the anisotropy, volume and particle interactions distributions, therefore thermal effects in nanoparticles systems conspire against a proper interpretation and analysis of these diagrams. Motivated by this fact, we have quantitatively studied the degree of accuracy of the information extracted from FORC diagrams for the special case of single-domain thermal corrected Stoner- Wohlfarth (easy axes along the external field orientation) nanoparticles systems. In this work, the starting point is an analytical model that describes the behavior of a magnetic nanoparticles system as a function of field, anisotropy, temperature and measurement time. In order to study the quantitative degree of accuracy of our model, we built FORC diagrams for different archetypical cases of magnetic nanoparticles. Our results show that from the quantitative information obtained from the diagrams, under the hypotheses of the proposed model, is possible to recover the features of the original system with accuracy above 95%. This accuracy is improved at low temperatures and also it is possible to access to the anisotropy distribution directly from the FORC coercive field profile. Indeed, our simulations predict that the volume distribution plays a secondary role being the mean value and its deviation the only important parameters. Therefore it is possible to obtain an accurate result for the inversion and interaction fields despite the features of the volume distribution.

  1. Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhandari, Deepak; Kertesz, Vilmos; Van Berkel, Gary J

    RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injectionmore » volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.« less

  2. Vibrational algorithms for quantitative crystallographic analyses of hydroxyapatite-based biomaterials: I, theoretical foundations.

    PubMed

    Pezzotti, Giuseppe; Zhu, Wenliang; Boffelli, Marco; Adachi, Tetsuya; Ichioka, Hiroaki; Yamamoto, Toshiro; Marunaka, Yoshinori; Kanamura, Narisato

    2015-05-01

    The Raman spectroscopic method has quantitatively been applied to the analysis of local crystallographic orientation in both single-crystal hydroxyapatite and human teeth. Raman selection rules for all the vibrational modes of the hexagonal structure were expanded into explicit functions of Euler angles in space and six Raman tensor elements (RTE). A theoretical treatment has also been put forward according to the orientation distribution function (ODF) formalism, which allows one to resolve the statistical orientation patterns of the nm-sized hydroxyapatite crystallite comprised in the Raman microprobe. Close-form solutions could be obtained for the Euler angles and their statistical distributions resolved with respect to the direction of the average texture axis. Polarized Raman spectra from single-crystalline hydroxyapatite and textured polycrystalline (teeth enamel) samples were compared, and a validation of the proposed Raman method could be obtained through confirming the agreement between RTE values obtained from different samples.

  3. The Importance of Economic Perspective and Quantitative Approaches in Oncology Value Frameworks of Drug Selection and Shared Decision Making.

    PubMed

    Waldeck, A Reginald; Botteman, Marc F; White, Richard E; van Hout, Ben A

    2017-06-01

    The debate around value in oncology drug selection has been prominent in recent years, and several professional bodies have furthered this debate by advocating for so-called value frameworks. Herein, we provide a viewpoint on these value frameworks, emphasizing the need to consider 4 key aspects: (1) the economic underpinnings of value; (2) the importance of the perspective adopted in the valuation; (3) the importance of the difference between absolute and relative measures of risk and measuring patient preferences; and (4) the recognition of multiple quality-of-life (QoL) domains, and the aggregation and valuation of those domains, through utilities within a multicriteria decision analysis, may allow prioritization of QoL above the tallying of safety events, particularly in a value framework focusing on the individual patient. While several frameworks exist, they incorporate different attributes and-importantly-assess value from alternative perspectives, including those of patients, regulators, payers, and society. The various perspectives necessarily lead to potentially different, if not sometimes divergent, conclusions about the valuation. We show that the perspective of the valuation affects the framing of the risk/benefit question and the methodology to measure the individual patient choice, or preference, as opposed to the collective, or population, choice. We focus specifically on the American Society of Clinical Oncology (ASCO) Value Framework. We argue that its laudable intent to assist in shared clinician-patient decision making can be augmented by more formally adopting methodology underpinned by micro- and health economic concepts, as well as application of formal quantitative approaches. Our recommendations for value frameworks focusing on the individual patient, such as the ASCO Value Framework, are 3-fold: (1) ensure that stakeholders understand the importance of the adopted (economic) perspective; (2) consider using exclusively absolute measures of

  4. Value of Information References

    DOE Data Explorer

    Morency, Christina

    2014-12-12

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  5. A systematic review of the angular values obtained by computerized photogrammetry in sagittal plane: a proposal for reference values.

    PubMed

    Krawczky, Bruna; Pacheco, Antonio G; Mainenti, Míriam R M

    2014-05-01

    Reference values for postural alignment in the coronal plane, as measured by computerized photogrammetry, have been established but not for the sagittal plane. The objective of this study is to propose reference values for angular measurements used for postural analysis in the sagittal plane for healthy adults. Electronic databases (PubMed, BVS, Cochrane, Scielo, and Science Direct) were searched using the following key words: evaluation, posture, photogrammetry, and software. Articles published between 2006 and 2012 that used the PAS/SAPO (postural assessment software) were selected. Another inclusion criterion was the presentation of, at least, one of the following measurements: head horizontal alignment, pelvic horizontal alignment, hip angle, vertical alignment of the body, thoracic kyphosis, and lumbar lordosis. Angle samples of the selected articles were grouped 2 by 2 in relation to an overall average, which made possible total average, variance, and SD calculations. Six articles were included, and the following average angular values were found: 51.42° ± 4.87° (head horizontal alignment), -12.26° ± 5.81° (pelvic horizontal alignment), -6.40° ± 3.86° (hip angle), and 1.73° ± 0.94° (vertical alignment of the body). None of the articles contained the measurements for thoracic kyphosis and lumbar lordosis. The reference values can be adopted as reference for postural assessment in future researches if the same anatomical points are considered. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  6. QUANTITATIVE PLUTONIUM MICRODISTRIBUTION IN BONE TISSUE OF VERTEBRA FROM A MAYAK WORKER

    PubMed Central

    Lyovkina, Yekaterina V.; Miller, Scott C.; Romanov, Sergey A.; Krahenbuhl, Melinda P.; Belosokhov, Maxim V.

    2010-01-01

    The purpose was to obtain quantitative data on plutonium microdistribution in different structural elements of human bone tissue for local dose assessment and dosimetric models validation. A sample of the thoracic vertebra was obtained from a former Mayak worker with a rather high plutonium burden. Additional information was obtained on occupational and exposure history, medical history, and measured plutonium content in organs. Plutonium was detected in bone sections from its fission tracks in polycarbonate film using neutron-induced autoradiography. Quantitative analysis of randomly selected microscopic fields on one of the autoradiographs was performed. Data included fission fragment tracks in different bone tissue and surface areas. Quantitative information on plutonium microdistribution in human bone tissue was obtained for the first time. From these data, quantitative relationship of plutonium decays in bone volume to decays on bone surface in cortical and trabecular fractions were defined as 2.0 and 0.4, correspondingly. The measured quantitative relationship of decays in bone volume to decays on bone surface does not coincide with recommended models for the cortical bone fraction by the International Commission on Radiological Protection. Biokinetic model parameters of extrapulmonary compartments might need to be adjusted after expansion of the data set on quantitative plutonium microdistribution in other bone types in human as well as other cases with different exposure patterns and types of plutonium. PMID:20838087

  7. Overview of Student Affairs Research Methods: Qualitative and Quantitative.

    ERIC Educational Resources Information Center

    Perl, Emily J.; Noldon, Denise F.

    2000-01-01

    Reviews the strengths and weaknesses of quantitative and qualitative research in student affairs research, noting that many student affairs professionals question the value of more traditional quantitative approaches to research, though they typically have very good people skills that they have applied to being good qualitative researchers.…

  8. Assessment of and standardization for quantitative nondestructive test

    NASA Technical Reports Server (NTRS)

    Neuschaefer, R. W.; Beal, J. B.

    1972-01-01

    Present capabilities and limitations of nondestructive testing (NDT) as applied to aerospace structures during design, development, production, and operational phases are assessed. It will help determine what useful structural quantitative and qualitative data may be provided from raw materials to vehicle refurbishment. This assessment considers metal alloys systems and bonded composites presently applied in active NASA programs or strong contenders for future use. Quantitative and qualitative data has been summarized from recent literature, and in-house information, and presented along with a description of those structures or standards where the information was obtained. Examples, in tabular form, of NDT technique capabilities and limitations have been provided. NDT techniques discussed and assessed were radiography, ultrasonics, penetrants, thermal, acoustic, and electromagnetic. Quantitative data is sparse; therefore, obtaining statistically reliable flaw detection data must be strongly emphasized. The new requirements for reusable space vehicles have resulted in highly efficient design concepts operating in severe environments. This increases the need for quantitative NDT evaluation of selected structural components, the end item structure, and during refurbishment operations.

  9. [VALUE OF SMART PHONE Scoliometer SOFTWARE IN OBTAINING OPTIMAL LUMBAR LORDOSIS DURING L4-S1 FUSION SURGERY].

    PubMed

    Yu, Weibo; Liang, De; Ye, Linqiang; Jiang, Xiaobing; Yao, Zhensong; Tang, Jingjing; Tang, Yongchao

    2015-10-01

    To investigate the value of smart phone Scoliometer software in obtaining optimal lumbar lordosis (LL) during L4-S1 fusion surgery. Between November 2014 and February 2015, 20 patients scheduled for L4-S1 fusion surgery were prospectively enrolled the study. There were 8 males and 12 females, aged 41-65 years (mean, 52.3 years). The disease duration ranged from 6 months to 6 years (mean, 3.4 years). Before operation, the pelvic incidence (PI) and Cobb angle of L4-S1 (CobbL4-S1) were measured on lateral X-ray film of lumbosacral spine by PACS system; and the ideal CobbL4-S1 was then calculated according to previously published methods [(PI+9 degrees) x 70%]. Subsequently, intraoperative CobbL4-S1 was monitored by the Scoliometer software and was defined as optimal while it was less than 5 degrees difference compared with ideal CobbL4-S1. Finally, the CobbL4-S1 was measured by the PACS system after operation and the consistency was compared between Scoliometer software and PACS system to evaluate the accuracy of this software. In addition, value of this method in obtaining optimal LL was validated by comparing the difference between ideal CobbL4-S1 and preoperative one with that between ideal CobbL4-S1 and postoperative one. The CobbL4-S1 was (36.17 ± 1.53)degrees for ideal one, (22.57 ± 5.50)degrees for preoperative one, (32.25 ± 1.46)degrees for intraoperative one measured by Scoliometer software, and (34.43 ± 1.72)degrees for postoperative one, respectively. The observed intraclass correlation coefficient (ICC) was excellent [ICC = 0.96, 95% confidence interval (0.93, 0.97)] and the mean absolute difference (MAD) was low (MAD = 1.23) between Scoliometer software and PACS system. The deviation between ideal CobbL4-S1 and postoperative CobbL4-S1 was (2.31 ± 0.23)degrees, which was significantly lower than the deviation between ideal CobbL4-S1 and preoperative CobbL4-S1 (13.60 ± 1.85)degrees (t = 6.065, P = 0.001). Scoliometer software can help surgeon obtain

  10. Improved quantitative analysis of spectra using a new method of obtaining derivative spectra based on a singular perturbation technique.

    PubMed

    Li, Zhigang; Wang, Qiaoyun; Lv, Jiangtao; Ma, Zhenhe; Yang, Linjuan

    2015-06-01

    Spectroscopy is often applied when a rapid quantitative analysis is required, but one challenge is the translation of raw spectra into a final analysis. Derivative spectra are often used as a preliminary preprocessing step to resolve overlapping signals, enhance signal properties, and suppress unwanted spectral features that arise due to non-ideal instrument and sample properties. In this study, to improve quantitative analysis of near-infrared spectra, derivatives of noisy raw spectral data need to be estimated with high accuracy. A new spectral estimator based on singular perturbation technique, called the singular perturbation spectra estimator (SPSE), is presented, and the stability analysis of the estimator is given. Theoretical analysis and simulation experimental results confirm that the derivatives can be estimated with high accuracy using this estimator. Furthermore, the effectiveness of the estimator for processing noisy infrared spectra is evaluated using the analysis of beer spectra. The derivative spectra of the beer and the marzipan are used to build the calibration model using partial least squares (PLS) modeling. The results show that the PLS based on the new estimator can achieve better performance compared with the Savitzky-Golay algorithm and can serve as an alternative choice for quantitative analytical applications.

  11. Shear-wave elastography quantitative assessment of the male breast: added value to distinguish benign and malignant palpable masses.

    PubMed

    Crombé, Amandine; Hurtevent-Labrot, Gabrielle; Asad-Syed, Maryam; Palussière, Jean; MacGrogan, Gaetan; Kind, Michèle; Ferron, Stéphane

    2018-02-01

    To evaluate the ability of shear-wave elastography (SWE) to distinguish between benign and malignant palpable masses of the adult male breast. Clinical examination, mammography, B-mode and Doppler ultrasound findings and SWE quantitative parameters were compared in 50 benign lesions (including 40 gynaecomastias) and 15 malignant lesions (invasive ductal carcinomas) from 65 patients who were consecutively addressed for specialized advice at our comprehensive cancer centre. Mean elasticity (El mean), maximum elasticity (El max), El mean of the surrounding fatty tissue and lesion to fat ratio (El ratio) were reported for each patient. Malignant masses displayed significantly higher El mean (p < 0.0001), El max (p < 0.0001) and El ratio (p < 0.0001) compared to benign masses without overlap of values between the two groups. By adding SWE to clinical examination, mammography and ultrasound, all the lesions would have been retrospectively correctly diagnosed as benign or malignant. One false positive could have been downstaged, 14/65 undetermined masses could have been correctly reclassified as 4 malignant and 10 benign lesions, for which biopsies could have consequently been avoided. Evaluation of male breast palpable masses by SWE demonstrates that malignant masses are significantly stiffer lesions and may improve diagnostic management when clinical examination, mammography and conventional ultrasound are doubtful. Advances in knowledge: Quantitative SWE is feasible in male breast and could be of great interest to help classify doubtful lesions after classical clinical and radiological evaluations, probably because of different anatomy and different tumours epidemiology compared with female breast.

  12. Quantitative measurement of the near-field enhancement of nanostructures by two-photon polymerization.

    PubMed

    Geldhauser, Tobias; Kolloch, Andreas; Murazawa, Naoki; Ueno, Kosei; Boneberg, Johannes; Leiderer, Paul; Scheer, Elke; Misawa, Hiroaki

    2012-06-19

    The quantitative determination of the strength of the near-field enhancement in and around nanostructures is essential for optimizing and using these structures for applications. We combine the gaussian intensity distribution of a laser profile and two-photon-polymerization of SU-8 to a suitable tool for the quantitative experimental measurement of the near-field enhancement of a nanostructure. Our results give a feedback to the results obtained by finite-difference time-domain (FDTD) simulations. The structures under investigation are gold nanotriangles on a glass substrate with 85 nm side length and a thickness of 40 nm. We compare the threshold fluence for polymerization for areas of the gaussian intensity profile with and without the near-field enhancement of the nanostructures. The experimentally obtained value of the near-field intensity enhancement is 600 ± 140, independent of the laser power, irradiation time, and spot size. The FDTD simulation shows a pointlike maximum of 2600 at the tip. In a more extended area with an approximate size close to the smallest polymerized structure of 25 nm in diameter, we find a value between 800 and 600. Using our novel approach, we determine the threshold fluence for polymerization of the commercially available photopolymerizable resin SU-8 by a femtosecond laser working at a wavelength of 795 nm and a repetition rate of 82 MHz to be 0.25 J/cm(2) almost independent of the irradiation time and the laser power used. This finding is important for future applications of the method because it enables one to use varying laser systems.

  13. Power laws and extreme values in antibody repertoires

    NASA Astrophysics Data System (ADS)

    Boyer, Sebastien; Biswas, Dipanwita; Scaramozzino, Natale; Kumar, Ananda Soshee; Nizak, Clément; Rivoire, Olivier

    2015-03-01

    Evolution by natural selection involves the succession of three steps: mutations, selection and proliferation. We are interested in describing and characterizing the result of selection over a population of many variants. After selection, this population will be dominated by the few best variants, with highest propensity to be selected, or highest ``selectivity.'' We ask the following question: how is the selectivity of the best variants distributed in the population? Extreme value theory, which characterizes the extreme tail of probability distributions in terms of a few universality class, has been proposed to describe it. To test this proposition and identify the relevant universality class, we performed quantitative in vitro experimental selections of libraries of >105 antibodies using the technique of phage display. Data obtained by high-throughput sequencing allows us to fit the selectivity distribution over more than two decades. In most experiments, the results show a striking power law for the selectivity distribution of the top antibodies, consistent with extreme value theory.

  14. A computer system to be used with laser-based endoscopy for quantitative diagnosis of early gastric cancer.

    PubMed

    Miyaki, Rie; Yoshida, Shigeto; Tanaka, Shinji; Kominami, Yoko; Sanomura, Yoji; Matsuo, Taiji; Oka, Shiro; Raytchev, Bisser; Tamaki, Toru; Koide, Tetsushi; Kaneda, Kazufumi; Yoshihara, Masaharu; Chayama, Kazuaki

    2015-02-01

    To evaluate the usefulness of a newly devised computer system for use with laser-based endoscopy in differentiating between early gastric cancer, reddened lesions, and surrounding tissue. Narrow-band imaging based on laser light illumination has come into recent use. We devised a support vector machine (SVM)-based analysis system to be used with the newly devised endoscopy system to quantitatively identify gastric cancer on images obtained by magnifying endoscopy with blue-laser imaging (BLI). We evaluated the usefulness of the computer system in combination with the new endoscopy system. We evaluated the system as applied to 100 consecutive early gastric cancers in 95 patients examined by BLI magnification at Hiroshima University Hospital. We produced a set of images from the 100 early gastric cancers; 40 flat or slightly depressed, small, reddened lesions; and surrounding tissues, and we attempted to identify gastric cancer, reddened lesions, and surrounding tissue quantitatively. The average SVM output value was 0.846 ± 0.220 for cancerous lesions, 0.381 ± 0.349 for reddened lesions, and 0.219 ± 0.277 for surrounding tissue, with the SVM output value for cancerous lesions being significantly greater than that for reddened lesions or surrounding tissue. The average SVM output value for differentiated-type cancer was 0.840 ± 0.207 and for undifferentiated-type cancer was 0.865 ± 0.259. Although further development is needed, we conclude that our computer-based analysis system used with BLI will identify gastric cancers quantitatively.

  15. Accuracy of quantitative visual soil assessment

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Maricke; Heuvelink, Gerard; Stoorvogel, Jetse; Wallinga, Jakob; de Boer, Imke; van Dam, Jos; van Essen, Everhard; Moolenaar, Simon; Verhoeven, Frank; Stoof, Cathelijne

    2016-04-01

    farmers carried out quantitative visual observations all independently from each other. All observers assessed five sites, having a sand, peat or clay soil. For almost all quantitative visual observations the spread of observed values was low (coefficient of variation < 1.0), except for the number of biopores and gley mottles. Furthermore, farmers' observed mean values were significantly higher than soil scientists' mean values, for soil structure, amount of gley mottles and compaction. This study showed that VSA could be a valuable tool to assess soil quality. Subjectivity, due to the background of the observer, might influence the outcome of visual assessment of some soil properties. In countries where soil analyses can easily be carried out, VSA might be a good replenishment to available soil chemical analyses, and in countries where it is not feasible to carry out soil analyses, VSA might be a good start to assess soil quality.

  16. Institutions' Espoused Values Perceived by Chinese Educational Leaders

    ERIC Educational Resources Information Center

    Pang, Nicholas Sun-Keung; Wang, Ting

    2012-01-01

    This paper presents some key findings of a quantitative study which assessed a group of Chinese educational leaders' value orientations. A survey instrument "The Institutional Values Inventory" was used to investigate their perspectives on the values espoused by their institutions in terms of traditional Confucian ethics and values of…

  17. SU-F-J-112: Clinical Feasibility Test of An RF Pulse-Based MRI Method for the Quantitative Fat-Water Segmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yee, S; Wloch, J; Pirkola, M

    Purpose: Quantitative fat-water segmentation is important not only because of the clinical utility of fat-suppressed MRI images in better detecting lesions of clinical significance (in the midst of bright fat signal) but also because of the possible physical need, in which CT-like images based on the materials’ photon attenuation properties may have to be generated from MR images; particularly, as in the case of MR-only radiation oncology environment to obtain radiation dose calculation or as in the case of hybrid PET/MR modality to obtain attenuation correction map for the quantitative PET reconstruction. The majority of such fat-water quantitative segmentations havemore » been performed by utilizing the Dixon’s method and its variations, which have to enforce the proper settings (often predefined) of echo time (TE) in the pulse sequences. Therefore, such methods have been unable to be directly combined with those ultrashort TE (UTE) sequences that, taking the advantage of very low TE values (∼ 10’s microsecond), might be beneficial to directly detect bones. Recently, an RF pulse-based method (http://dx.doi.org/10.1016/j.mri.2015.11.006), termed as PROD pulse method, was introduced as a method of quantitative fat-water segmentation that does not have to depend on predefined TE settings. Here, the clinical feasibility of this method is verified in brain tumor patients by combining the PROD pulse with several sequences. Methods: In a clinical 3T MRI, the PROD pulse was combined with turbo spin echo (e.g. TR=1500, TE=16 or 60, ETL=15) or turbo field echo (e.g. TR=5.6, TE=2.8, ETL=12) sequences without specifying TE values. Results: The fat-water segmentation was possible without having to set specific TE values. Conclusion: The PROD pulse method is clinically feasible. Although not yet combined with UTE sequences in our laboratory, the method is potentially compatible with UTE sequences, and thus, might be useful to directly segment fat, water, bone and air.« less

  18. Quantitative water content mapping at clinically relevant field strengths: a comparative study at 1.5 T and 3 T.

    PubMed

    Abbas, Zaheer; Gras, Vincent; Möllenhoff, Klaus; Oros-Peusquens, Ana-Maria; Shah, Nadim Joni

    2015-02-01

    Quantitative water content mapping in vivo using MRI is a very valuable technique to detect, monitor and understand diseases of the brain. At 1.5 T, this technology has already been successfully used, but it has only recently been applied at 3T because of significantly increased RF field inhomogeneity at the higher field strength. To validate the technology at 3T, we estimate and compare in vivo quantitative water content maps at 1.5 T and 3T obtained with a protocol proposed recently for 3T MRI. The proposed MRI protocol was applied on twenty healthy subjects at 1.5 T and 3T; the same post-processing algorithms were used to estimate the water content maps. The 1.5 T and 3T maps were subsequently aligned and compared on a voxel-by-voxel basis. Statistical analysis was performed to detect possible differences between the estimated 1.5 T and 3T water maps. Our analysis indicates that the water content values obtained at 1.5 T and 3T did not show significant systematic differences. On average the difference did not exceed the standard deviation of the water content at 1.5 T. Furthermore, the contrast-to-noise ratio (CNR) of the estimated water content map was increased at 3T by a factor of at least 1.5. Vulnerability to RF inhomogeneity increases dramatically with the increasing static magnetic field strength. However, using advanced corrections for the sensitivity profile of the MR coils, it is possible to preserve quantitative accuracy while benefiting from the increased CNR at the higher field strength. Indeed, there was no significant difference in the water content values obtained in the brain at 1.5 T and 3T. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Comparison of Absolute Apparent Diffusion Coefficient (ADC) Values in ADC Maps Generated Across Different Postprocessing Software: Reproducibility in Endometrial Carcinoma.

    PubMed

    Ghosh, Adarsh; Singh, Tulika; Singla, Veenu; Bagga, Rashmi; Khandelwal, Niranjan

    2017-12-01

    Apparent diffusion coefficient (ADC) maps are usually generated by builtin software provided by the MRI scanner vendors; however, various open-source postprocessing software packages are available for image manipulation and parametric map generation. The purpose of this study is to establish the reproducibility of absolute ADC values obtained using different postprocessing software programs. DW images with three b values were obtained with a 1.5-T MRI scanner, and the trace images were obtained. ADC maps were automatically generated by the in-line software provided by the vendor during image generation and were also separately generated on postprocessing software. These ADC maps were compared on the basis of ROIs using paired t test, Bland-Altman plot, mountain plot, and Passing-Bablok regression plot. There was a statistically significant difference in the mean ADC values obtained from the different postprocessing software programs when the same baseline trace DW images were used for the ADC map generation. For using ADC values as a quantitative cutoff for histologic characterization of tissues, standardization of the postprocessing algorithm is essential across processing software packages, especially in view of the implementation of vendor-neutral archiving.

  20. Valuing inter-sectoral costs and benefits of interventions in the healthcare sector: methods for obtaining unit prices.

    PubMed

    Drost, Ruben M W A; Paulus, Aggie T G; Ruwaard, Dirk; Evers, Silvia M A A

    2017-02-01

    There is a lack of knowledge about methods for valuing health intervention-related costs and monetary benefits in the education and criminal justice sectors, also known as 'inter-sectoral costs and benefits' (ICBs). The objective of this study was to develop methods for obtaining unit prices for the valuation of ICBs. By conducting an exploratory literature study and expert interviews, several generic methods were developed. The methods' feasibility was assessed through application in the Netherlands. Results were validated in an expert meeting, which was attended by policy makers, public health experts, health economists and HTA-experts, and discussed at several international conferences and symposia. The study resulted in four methods, including the opportunity cost method (A) and valuation using available unit prices (B), self-constructed unit prices (C) or hourly labor costs (D). The methods developed can be used internationally and are valuable for the broad international field of HTA.

  1. Vertebral heights and ratios are not only race-specific, but also gender- and region-specific: establishment of reference values for mainland Chinese.

    PubMed

    Ning, Lei; Song, Li-Jiang; Fan, Shun-Wu; Zhao, Xing; Chen, Yi-Lei; Li, Zhao-Zhi; Hu, Zi-Ang

    2017-10-11

    This study established gender-specific reference values in mainland Chinese (MC) and is important for quantitative morphometry for diagnosis and epidemiological study of osteoporotic vertebral compressive fracture. Comparisons of reference values among different racial populations are then performed to demonstrate the MC-specific characteristic. Osteoporotic vertebral compressive fracture (OVCF) is a common complication of osteoporosis in the elder population. Clinical diagnosis and epidemiological study of OVCF often employ quantitative morphometry, which relies heavily on the comparison of patients' vertebral parameters to existing reference values derived from the normal population. Thus, reference values are crucial in clinical diagnosis. To our knowledge, this is the first study to establish reference values of the mainland Chinese (MC) for quantitative morphometry. Vertebral heights including anterior (Ha), middle (Hm), posterior (Hp) heights, and predicted posterior height (pp) from T4 to L5 were obtained; and ratios of Ha/Hp, Hm/Hp and Hp/pp. were calculated from 585 MC (both female and male) for establishing reference values and subsequent comparisons with other studies. Vertebral heights increased progressively from T4 to L3 but then decreased in L4 and L5. Both genders showed similar ratios of vertebral dimensions, but male vertebrae were statistically larger than those of female (P < 0.01). Vertebral size of MC population was smaller than that of US and UK population, but was surprisingly larger than that of Hong Kong Chinese, although these two are commonly considered as one race. Data from different racial populations showed similar dimensional ratios in all vertebrae. We established gender-specific reference values for MC. Our results also indicated the necessity of establishing reference values that are not only race- and gender-specific, but also population- or region-specific for accurate quantitative morphometric assessment of OVCF.

  2. Quantitative Assessment of Neovascularization after Indirect Bypass Surgery: Color-Coded Digital Subtraction Angiography in Pediatric Moyamoya Disease.

    PubMed

    Cho, H-H; Cheon, J-E; Kim, S-K; Choi, Y H; Kim, I-O; Kim, W S; Lee, S-M; You, S K; Shin, S-M

    2016-05-01

    For the postoperative follow-up in pediatric patients with Moyamoya disease, it is essential to evaluate the degree of neovascularization status. Our aim was to quantitatively assess the neovascularization status after bypass surgery in pediatric Moyamoya disease by using color-coded digital subtraction angiography. Time-attenuation intensity curves were generated at ROIs corresponding to surgical flap sites from color-coded DSA images of the common carotid artery, internal carotid artery, and external carotid artery angiograms obtained pre- and postoperatively in 32 children with Moyamoya disease. Time-to-peak and area under the curve values were obtained. Postoperative changes in adjusted time-to-peak (ΔTTP) and ratios of adjusted area under the curve changes (ΔAUC ratio) of common carotid artery, ICA, and external carotid artery angiograms were compared across clinical and angiographic outcome groups. To analyze diagnostic performance, we categorized clinical outcomes into favorable and unfavorable groups. The ΔTTP at the common carotid artery increased among clinical and angiographic outcomes, in that order, with significant differences (P = .003 and .005, respectively). The ΔAUC ratio at the common carotid artery and external carotid artery also increased, in that order, among clinical and angiographic outcomes with a significant difference (all, P = .000). The ΔAUC ratio of ICA showed no significant difference among clinical and angiographic outcomes (P = .418 and .424, respectively). The ΔTTP for the common carotid artery of >1.27 seconds and the ΔAUC ratio of >33.5% for the common carotid artery and 504% for the external carotid artery are revealed as optimal cutoff values between favorable and unfavorable groups. Postoperative changes in quantitative values obtained with color-coded DSA software showed a significant correlation with outcome scores and can be used as objective parameters for predicting the outcome in pediatric Moyamoya disease, with

  3. A quantitative description for efficient financial markets

    NASA Astrophysics Data System (ADS)

    Immonen, Eero

    2015-09-01

    In this article we develop a control system model for describing efficient financial markets. We define the efficiency of a financial market in quantitative terms by robust asymptotic price-value equality in this model. By invoking the Internal Model Principle of robust output regulation theory we then show that under No Bubble Conditions, in the proposed model, the market is efficient if and only if the following conditions hold true: (1) the traders, as a group, can identify any mispricing in asset value (even if no one single trader can do it accurately), and (2) the traders, as a group, incorporate an internal model of the value process (again, even if no one single trader knows it). This main result of the article, which deliberately avoids the requirement for investor rationality, demonstrates, in quantitative terms, that the more transparent the markets are, the more efficient they are. An extensive example is provided to illustrate the theoretical development.

  4. Interpretation of protein quantitation using the Bradford assay: comparison with two calculation models.

    PubMed

    Ku, Hyung-Keun; Lim, Hyuk-Min; Oh, Kyong-Hwa; Yang, Hyo-Jin; Jeong, Ji-Seon; Kim, Sook-Kyung

    2013-03-01

    The Bradford assay is a simple method for protein quantitation, but variation in the results between proteins is a matter of concern. In this study, we compared and normalized quantitative values from two models for protein quantitation, where the residues in the protein that bind to anionic Coomassie Brilliant Blue G-250 comprise either Arg and Lys (Method 1, M1) or Arg, Lys, and His (Method 2, M2). Use of the M2 model yielded much more consistent quantitation values compared with use of the M1 model, which exhibited marked overestimations against protein standards. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Sweat conductivity and coulometric quantitative test in neonatal cystic fibrosis screening.

    PubMed

    Domingos, Mouseline Torquato; Magdalena, Neiva Isabel Rodrigues; Cat, Mônica Nunes Lima; Watanabe, Alexandra Mitiru; Rosário Filho, Nelson Augusto

    2015-01-01

    To compare the results obtained with the sweat test using the conductivity method and coulometric measurement of sweat chloride in newborns (NBs) with suspected cystic fibrosis (CF) in the neonatal screening program. The sweat test was performed simultaneously by both methods in children with and without CF. The cutoff values to confirm CF were >50 mmol/L in the conductivity and >60 mmol/L in the coulometric test. There were 444 infants without CF (185 males, 234 females, and 24 unreported) submitted to the sweat test through conductivity and coulometric measurement simultaneously, obtaining median results of 32 mmol/L and 12 mmol/L, respectively. For 90 infants with CF, the median values of conductivity and coulometric measurement were 108 mmol/L and 97 mmol/L, respectively. The false positive rate for conductivity was 16.7%, and was higher than 50 mmol/L in all patients with CF, which gives this method a sensitivity of 100% (95% CI: 93.8-97.8), specificity of 96.2% (95% CI: 93.8-97.8), positive predictive value of 83.3% (95% CI: 74.4-91.1), negative predictive value of 100% (95% CI: 90.5-109.4), and 9.8% accuracy. The correlation between the methods was r=0.97 (p>0.001). The best suggested cutoff value was 69.0 mmol/L, with a kappa coefficient=0.89. The conductivity test showed excellent correlation with the quantitative coulometric test, high sensitivity and specificity, and can be used in the diagnosis of CF in children detected through newborn screening. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  6. Quantitative Approaches to Group Research: Suggestions for Best Practices

    ERIC Educational Resources Information Center

    McCarthy, Christopher J.; Whittaker, Tiffany A.; Boyle, Lauren H.; Eyal, Maytal

    2017-01-01

    Rigorous scholarship is essential to the continued growth of group work, yet the unique nature of this counseling specialty poses challenges for quantitative researchers. The purpose of this proposal is to overview unique challenges to quantitative research with groups in the counseling field, including difficulty in obtaining large sample sizes…

  7. [Development and validation of event-specific quantitative PCR method for genetically modified maize LY038].

    PubMed

    Mano, Junichi; Masubuchi, Tomoko; Hatano, Shuko; Futo, Satoshi; Koiwa, Tomohiro; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Akiyama, Hiroshi; Teshima, Reiko; Kurashima, Takeyo; Takabatake, Reona; Kitta, Kazumi

    2013-01-01

    In this article, we report a novel real-time PCR-based analytical method for quantitation of the GM maize event LY038. We designed LY038-specific and maize endogenous reference DNA-specific PCR amplifications. After confirming the specificity and linearity of the LY038-specific PCR amplification, we determined the conversion factor required to calculate the weight-based content of GM organism (GMO) in a multilaboratory evaluation. Finally, in order to validate the developed method, an interlaboratory collaborative trial according to the internationally harmonized guidelines was performed with blind DNA samples containing LY038 at the mixing levels of 0, 0.5, 1.0, 5.0 and 10.0%. The precision of the method was evaluated as the RSD of reproducibility (RSDR), and the values obtained were all less than 25%. The limit of quantitation of the method was judged to be 0.5% based on the definition of ISO 24276 guideline. The results from the collaborative trial suggested that the developed quantitative method would be suitable for practical testing of LY038 maize.

  8. Enhanced Detection of Surface-Associated Bacteria in Indoor Environments by Quantitative PCR

    PubMed Central

    Buttner, Mark P.; Cruz-Perez, Patricia; Stetzenbach, Linda D.

    2001-01-01

    Methods for detecting microorganisms on surfaces are needed to locate biocontamination sources and to relate surface and airborne concentrations. Research was conducted in an experimental room to evaluate surface sampling methods and quantitative PCR (QPCR) for enhanced detection of a target biocontaminant present on flooring materials. QPCR and culture analyses were used to quantitate Bacillus subtilis (Bacillus globigii) endospores on vinyl tile, commercial carpet, and new and soiled residential carpet with samples obtained by four surface sampling methods: a swab kit, a sponge swipe, a cotton swab, and a bulk method. The initial data showed that greater overall sensitivity was obtained with the QPCR than with culture analysis; however, the QPCR results for bulk samples from residential carpet were negative. The swab kit and the sponge swipe methods were then tested with two levels of background biological contamination consisting of Penicillium chrysogenum spores. The B. subtilis values obtained by the QPCR method were greater than those obtained by culture analysis. The differences between the QPCR and culture data were significant for the samples obtained with the swab kit for all flooring materials except soiled residential carpet and with the sponge swipe for commercial carpet. The QPCR data showed that there were no significant differences between the swab kit and sponge swipe sampling methods for any of the flooring materials. Inhibition of QPCR due solely to biological contamination of flooring materials was not evident. However, some degree of inhibition was observed with the soiled residential carpet, which may have been caused by the presence of abiotic contaminants, alone or in combination with biological contaminants. The results of this research demonstrate the ability of QPCR to enhance detection and enumeration of biocontaminants on surface materials and provide information concerning the comparability of currently available surface sampling

  9. Professional values of nurse lecturers at three universities in Colombia.

    PubMed

    López-Pereira, Arabely; Arango-Bayer, Gloria

    2017-03-01

    To describe the professional values of the nurse lectures according to 241 nursing students, who participated voluntarily, in three different universities of Bogotá. This is a quantitative, descriptive cross-sectional study that applied the Nurses Professional Values Scale-permission secured-Spanish; three dimensions of values were applied: ethics, commitment, and professional knowledge. Ethical consideration: Project had ethical review and approval from an ethics committee and participants were given information sheets to read before they agreed to participate in the project. It was concluded that nursing students, in general, do perceive these values in their professors, and they give priority to the dimension of ethics, followed by the knowledge dimension, and finally, commitment. It is evident that professional values are transmitted by professors and students place importance to such values. Values related to the other's care are paramount in nursing training in Colombia as well as in other countries. It was found that participating students observed professors directly in relation to values focused on direct patient care, respect for privacy, respect for life, while matters related to professional improvement, participation in unions were not actually analyzed may be due to poor promotion activities and unions during undergraduate studies. The results obtained are primary approach to the study of values related to nursing, a topic which needs to be researched, something vital to all the country offering nursing training programs.

  10. Quantitative assessment of changes in landslide risk using a regional scale run-out model

    NASA Astrophysics Data System (ADS)

    Hussin, Haydar; Chen, Lixia; Ciurean, Roxana; van Westen, Cees; Reichenbach, Paola; Sterlacchini, Simone

    2015-04-01

    The risk of landslide hazard continuously changes in time and space and is rarely a static or constant phenomena in an affected area. However one of the main challenges of quantitatively assessing changes in landslide risk is the availability of multi-temporal data for the different components of risk. Furthermore, a truly "quantitative" landslide risk analysis requires the modeling of the landslide intensity (e.g. flow depth, velocities or impact pressures) affecting the elements at risk. Such a quantitative approach is often lacking in medium to regional scale studies in the scientific literature or is left out altogether. In this research we modelled the temporal and spatial changes of debris flow risk in a narrow alpine valley in the North Eastern Italian Alps. The debris flow inventory from 1996 to 2011 and multi-temporal digital elevation models (DEMs) were used to assess the susceptibility of debris flow triggering areas and to simulate debris flow run-out using the Flow-R regional scale model. In order to determine debris flow intensities, we used a linear relationship that was found between back calibrated physically based Flo-2D simulations (local scale models of five debris flows from 2003) and the probability values of the Flow-R software. This gave us the possibility to assign flow depth to a total of 10 separate classes on a regional scale. Debris flow vulnerability curves from the literature and one curve specifically for our case study area were used to determine the damage for different material and building types associated with the elements at risk. The building values were obtained from the Italian Revenue Agency (Agenzia delle Entrate) and were classified per cadastral zone according to the Real Estate Observatory data (Osservatorio del Mercato Immobiliare, Agenzia Entrate - OMI). The minimum and maximum market value for each building was obtained by multiplying the corresponding land-use value (€/msq) with building area and number of floors

  11. A discrete choice experiment to obtain a tariff for valuing informal care situations measured with the CarerQol instrument.

    PubMed

    Hoefman, Renske J; van Exel, Job; Rose, John M; van de Wetering, E J; Brouwer, Werner B F

    2014-01-01

    Economic evaluations adopting a societal perspective need to include informal care whenever relevant. However, in practice, informal care is often neglected, because there are few validated instruments to measure and value informal care for inclusion in economic evaluations. The CarerQol, which is such an instrument, measures the impact of informal care on 7 important burden dimensions (CarerQol-7D) and values this in terms of general quality of life (CarerQol-VAS). The objective of the study was to calculate utility scores based on relative utility weights for the CarerQol-7D. These tariffs will facilitate inclusion of informal care in economic evaluations. The CarerQol-7D tariff was derived with a discrete choice experiment conducted as an Internet survey among the general adult population in the Netherlands (N = 992). The choice set contained 2 unlabeled alternatives described in terms of the 7 CarerQol-7D dimensions (level range: "no,"some," and "a lot"). An efficient experimental design with priors obtained from a pilot study (N = 104) was used. Data were analyzed with a panel mixed multinomial parameter model including main and interaction effects of the attributes. The utility attached to informal care situations was significantly higher when this situation was more attractive in terms of fewer problems and more fulfillment or support. The interaction term between the CarerQol-7D dimensions physical health and mental health problems also significantly explained this utility. The tariff was constructed by adding up the relative utility weights per category of all CarerQol-7D dimensions and the interaction term. We obtained a tariff providing standard utility scores for caring situations described with the CarerQol-7D. This facilitates the inclusion of informal care in economic evaluations.

  12. A quantitative analysis of sensitivity to the conditioned reinforcing value of terminal-link stimuli in a concurrent-chains schedule.

    PubMed Central

    Omino, T

    1993-01-01

    Pigeons were exposed to a concurrent-chains schedule in which a single variable-interval 30-s schedule was used in the initial links and fixed-time schedules were used in the terminal links. Three types of keylight conditions were used in the terminal links. In the first condition, different delays were associated with different keylight stimuli (cued condition). In the second condition, different delays were associated with the same stimulus, either a blackout (uncued blackout condition) or a white key (uncued white condition). Paired values of terminal-link fixed-time schedules differed by a constant ratio of 3:1, while the absolute value of delays was varied from 3 s to 54 s. The results showed that choice proportions for the shorter of two delays increased when the absolute size of the delays was increased for all keylight conditions. Further, the choice proportions for the shorter delay increased from the uncued blackout condition, to the uncued white condition, to the cued condition. A modified version of Fantino's (1969) delay-reduction model (expressed as a function relating the response ratio to the delay-reduction ratio) can be applied to these data by showing that sensitivity to delay reduction increased from the uncued blackout condition, to the uncued white condition, to the cued condition. Thus, the present study demonstrated that a modified version of the delay-reduction model can be used to assess quantitative differences in the terminal-link keylight condition in terms of sensitivity to delay reduction (i.e., the conditioned reinforcing value of the terminal-link keylight stimuli). PMID:8283150

  13. Exploring Students' Articulation of Value in a Social Research Methods Class: Towards a Phenomenography of Value Making

    ERIC Educational Resources Information Center

    Guglietti, Maria

    2015-01-01

    This study describes journalism students' value making of social research methods, such as sampling, data gathering strategies and quantitative and qualitative data analysis, by using a mixed-­method approach to analyze 260 written reflection assignments. In their reflections, 26 student participants assessed the value of their new knowledge of…

  14. Eifel maars: Quantitative shape characterization of juvenile ash particles (Eifel Volcanic Field, Germany)

    NASA Astrophysics Data System (ADS)

    Rausch, Juanita; Grobéty, Bernard; Vonlanthen, Pierre

    2015-01-01

    The Eifel region in western central Germany is the type locality for maar volcanism, which is classically interpreted to be the result of explosive eruptions due to shallow interaction between magma and external water (i.e. phreatomagmatic eruptions). Sedimentary structures, deposit features and particle morphology found in many maar deposits of the West Eifel Volcanic Field (WEVF), in contrast to deposits in the East Eifel Volcanic Field (EEVF), lack the diagnostic criteria of typical phreatomagmatic deposits. The aim of this study was to determine quantitatively the shape of WEVF and EEVF maar ash particles in order to infer the governing eruption style in Eifel maar volcanoes. The quantitative shape characterization was done by analyzing fractal dimensions of particle contours (125-250 μm sieve fraction) obtained from Scanning electron microscopy (SEM) and SEM micro-computed tomography (SEM micro-CT) images. The fractal analysis (dilation method) and the fractal spectrum technique confirmed that the WEVF and EEVF maar particles have contrasting multifractal shapes. Whereas the low small-scale dimensions of EEVF particles (Eppelsberg Green Unit) coincide with previously published values for phreatomagmatic particles, the WEVF particles (Meerfelder Maar, Pulvermaar and Ulmener Maar) have larger values indicating more complex small-scale features, which are characteristic for magmatic particles. These quantitative results are strengthening the qualitative microscopic observations, that the studied WEVF maar eruptions are rather dominated by magmatic processes. The different eruption styles in the two volcanic fields can be explained by the different geological and hydrological settings found in both regions and the different chemical compositions of the magmas.

  15. Stability of Gradient Field Corrections for Quantitative Diffusion MRI.

    PubMed

    Rogers, Baxter P; Blaber, Justin; Welch, E Brian; Ding, Zhaohua; Anderson, Adam W; Landman, Bennett A

    2017-02-11

    In magnetic resonance diffusion imaging, gradient nonlinearity causes significant bias in the estimation of quantitative diffusion parameters such as diffusivity, anisotropy, and diffusion direction in areas away from the magnet isocenter. This bias can be substantially reduced if the scanner- and coil-specific gradient field nonlinearities are known. Using a set of field map calibration scans on a large (29 cm diameter) phantom combined with a solid harmonic approximation of the gradient fields, we predicted the obtained b-values and applied gradient directions throughout a typical field of view for brain imaging for a typical 32-direction diffusion imaging sequence. We measured the stability of these predictions over time. At 80 mm from scanner isocenter, predicted b-value was 1-6% different than intended due to gradient nonlinearity, and predicted gradient directions were in error by up to 1 degree. Over the course of one month the change in these quantities due to calibration-related factors such as scanner drift and variation in phantom placement was <0.5% for b-values, and <0.5 degrees for angular deviation. The proposed calibration procedure allows the estimation of gradient nonlinearity to correct b-values and gradient directions ahead of advanced diffusion image processing for high angular resolution data, and requires only a five-minute phantom scan that can be included in a weekly or monthly quality assurance protocol.

  16. Quantitative analysis of drainage obtained from aerial photographs and RBV/LANDSAT images

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N. (Principal Investigator); Formaggio, A. R.; Epiphanio, J. C. N.; Filho, M. V.

    1981-01-01

    Data obtained from aerial photographs (1:60,000) and LANDSAT return beam vidicon imagery (1:100,000) concerning drainage density, drainage texture, hydrography density, and the average length of channels were compared. Statistical analysis shows that significant differences exist in data from the two sources. The highly drained area lost more information than the less drained area. In addition, it was observed that the loss of information about the number of rivers was higher than that about the length of the channels.

  17. Communication patterns in a psychotherapy following traumatic brain injury: A quantitative case study based on symbolic dynamics

    PubMed Central

    2011-01-01

    Background The role of psychotherapy in the treatment of traumatic brain injury is receiving increased attention. The evaluation of psychotherapy with these patients has been conducted largely in the absence of quantitative data concerning the therapy itself. Quantitative methods for characterizing the sequence-sensitive structure of patient-therapist communication are now being developed with the objective of improving the effectiveness of psychotherapy following traumatic brain injury. Methods The content of three therapy session transcripts (sessions were separated by four months) obtained from a patient with a history of several motor vehicle accidents who was receiving dialectical behavior therapy was scored and analyzed using methods derived from the mathematical theory of symbolic dynamics. Results The analysis of symbol frequencies was largely uninformative. When repeated triples were examined a marked pattern of change in content was observed over the three sessions. The context free grammar complexity and the Lempel-Ziv complexity were calculated for each therapy session. For both measures, the rate of complexity generation, expressed as bits per minute, increased longitudinally during the course of therapy. The between-session increases in complexity generation rates are consistent with calculations of mutual information. Taken together these results indicate that there was a quantifiable increase in the variability of patient-therapist verbal behavior during the course of therapy. Comparison of complexity values against values obtained from equiprobable random surrogates established the presence of a nonrandom structure in patient-therapist dialog (P = .002). Conclusions While recognizing that only limited conclusions can be based on a case history, it can be noted that these quantitative observations are consistent with qualitative clinical observations of increases in the flexibility of discourse during therapy. These procedures can be of particular

  18. Deep Learning for Magnetic Resonance Fingerprinting: A New Approach for Predicting Quantitative Parameter Values from Time Series.

    PubMed

    Hoppe, Elisabeth; Körzdörfer, Gregor; Würfl, Tobias; Wetzl, Jens; Lugauer, Felix; Pfeuffer, Josef; Maier, Andreas

    2017-01-01

    The purpose of this work is to evaluate methods from deep learning for application to Magnetic Resonance Fingerprinting (MRF). MRF is a recently proposed measurement technique for generating quantitative parameter maps. In MRF a non-steady state signal is generated by a pseudo-random excitation pattern. A comparison of the measured signal in each voxel with the physical model yields quantitative parameter maps. Currently, the comparison is done by matching a dictionary of simulated signals to the acquired signals. To accelerate the computation of quantitative maps we train a Convolutional Neural Network (CNN) on simulated dictionary data. As a proof of principle we show that the neural network implicitly encodes the dictionary and can replace the matching process.

  19. A Quantitative Infrared Spectroscopy Experiment.

    ERIC Educational Resources Information Center

    Krahling, Mark D.; Eliason, Robert

    1985-01-01

    Although infrared spectroscopy is used primarily for qualitative identifications, it is possible to use it as a quantitative tool as well. The use of a standard curve to determine percent methanol in a 2,2,2-trifluoroethanol sample is described. Background information, experimental procedures, and results obtained are provided. (JN)

  20. Clinical value of patient-specific three-dimensional printing of congenital heart disease: Quantitative and qualitative assessments

    PubMed Central

    Lau, Ivan Wen Wen; Liu, Dongting; Xu, Lei; Fan, Zhanming

    2018-01-01

    Objective Current diagnostic assessment tools remain suboptimal in demonstrating complex morphology of congenital heart disease (CHD). This limitation has posed several challenges in preoperative planning, communication in medical practice, and medical education. This study aims to investigate the dimensional accuracy and the clinical value of 3D printed model of CHD in the above three areas. Methods Using cardiac computed tomography angiography (CCTA) data, a patient-specific 3D model of a 20-month-old boy with double outlet right ventricle was printed in Tango Plus material. Pearson correlation coefficient was used to evaluate correlation of the quantitative measurements taken at analogous anatomical locations between the CCTA images pre- and post-3D printing. Qualitative analysis was conducted by distributing surveys to six health professionals (two radiologists, two cardiologists and two cardiac surgeons) and three medical academics to assess the clinical value of the 3D printed model in these three areas. Results Excellent correlation (r = 0.99) was noted in the measurements between CCTA and 3D printed model, with a mean difference of 0.23 mm. Four out of six health professionals found the model to be useful in facilitating preoperative planning, while all of them thought that the model would be invaluable in enhancing patient-doctor communication. All three medical academics found the model to be helpful in teaching, and thought that the students will be able to learn the pathology quicker with better understanding. Conclusion The complex cardiac anatomy can be accurately replicated in flexible material using 3D printing technology. 3D printed heart models could serve as an excellent tool in facilitating preoperative planning, communication in medical practice, and medical education, although further studies with inclusion of more clinical cases are needed. PMID:29561912

  1. Null Hypothesis Significance Testing and "p" Values

    ERIC Educational Resources Information Center

    Travers, Jason C.; Cook, Bryan G.; Cook, Lysandra

    2017-01-01

    "p" values are commonly reported in quantitative research, but are often misunderstood and misinterpreted by research consumers. Our aim in this article is to provide special educators with guidance for appropriately interpreting "p" values, with the broader goal of improving research consumers' understanding and interpretation…

  2. Obtaining the Iodine Value of Various Oils via Bromination with Pyridinium Tribromide

    ERIC Educational Resources Information Center

    Simurdiak, Michael; Olukoga, Olushola; Hedberg, Kirk

    2016-01-01

    A laboratory exercise was devised that allows students to rapidly and fairly accurately determine the iodine value of oleic acid. This method utilizes the addition of elemental bromine to the unsaturated bonds in oleic acid, due to bromine's relatively fast reaction rate compared to that of the traditional Wijs solution method. This method also…

  3. Quantitative analysis of diffusion tensor imaging (DTI) using statistical parametric mapping (SPM) for brain disorders

    NASA Astrophysics Data System (ADS)

    Lee, Jae-Seung; Im, In-Chul; Kang, Su-Man; Goo, Eun-Hoe; Kwak, Byung-Joon

    2013-07-01

    This study aimed to quantitatively analyze data from diffusion tensor imaging (DTI) using statistical parametric mapping (SPM) in patients with brain disorders and to assess its potential utility for analyzing brain function. DTI was obtained by performing 3.0-T magnetic resonance imaging for patients with Alzheimer's disease (AD) and vascular dementia (VD), and the data were analyzed using Matlab-based SPM software. The two-sample t-test was used for error analysis of the location of the activated pixels. We compared regions of white matter where the fractional anisotropy (FA) values were low and the apparent diffusion coefficients (ADCs) were increased. In the AD group, the FA values were low in the right superior temporal gyrus, right inferior temporal gyrus, right sub-lobar insula, and right occipital lingual gyrus whereas the ADCs were significantly increased in the right inferior frontal gyrus and right middle frontal gyrus. In the VD group, the FA values were low in the right superior temporal gyrus, right inferior temporal gyrus, right limbic cingulate gyrus, and right sub-lobar caudate tail whereas the ADCs were significantly increased in the left lateral globus pallidus and left medial globus pallidus. In conclusion by using DTI and SPM analysis, we were able to not only determine the structural state of the regions affected by brain disorders but also quantitatively analyze and assess brain function.

  4. Concordance of macular pigment measurements obtained using customized heterochromatic flicker photometry, dual-wavelength autofluorescence, and single-wavelength reflectance.

    PubMed

    Dennison, Jessica L; Stack, Jim; Beatty, Stephen; Nolan, John M

    2013-11-01

    This study compares in vivo measurements of macular pigment (MP) obtained using customized heterochromatic flicker photometry (cHFP; Macular Metrics Densitometer(™)), dual-wavelength fundus autofluorescence (Heidelberg Spectralis(®) HRA + OCT MultiColor) and single-wavelength fundus reflectance (Zeiss Visucam(®) 200). MP was measured in one eye of 62 subjects on each device. Data from 49 subjects (79%) was suitable for analysis. Agreement between the Densitometer and Spectralis was investigated at various eccentricities using a variety of quantitative and graphical methods, including: Pearson correlation coefficient to measure degree of scatter (precision), accuracy coefficient, concordance correlation coefficient (ccc), paired t-test, scatter and Bland-Altman plots. The relationship between max MP from the Visucam and central MP from the Spectralis and Densitometer was investigated using regression methods. Agreement was strong between the Densitometer and Spectralis at all central eccentricities (e.g. at 0.25° eccentricity: accuracy = 0.97, precision = 0.90, ccc = 0.87). Regression analysis showed a very weak relationship between the Visucam and Densitometer (e.g. Visucam max on Densitometer central MP: R(2) = 0.008, p = 0.843). Regression analysis also demonstrated a weak relationship between MP measured by the Spectralis and Visucam (e.g. Visucam max on Spectralis central MP: R(2) = 0.047, p = 0.348). MP values obtained using the Heidelberg Spectralis are comparable to MP values obtained using the Densitometer. In contrast, MP values obtained using the Zeiss Visucam are not comparable with either the Densitometer or the Spectralis MP measuring devices. Taking cHFP as the current standard to which other MP measuring devices should be compared, the Spectralis is suitable for use in a clinical and research setting, whereas the Visucam is not. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Quantitation of glycerophosphorylcholine by flow injection analysis using immobilized enzymes.

    PubMed

    Mancini, A; Del Rosso, F; Roberti, R; Caligiana, P; Vecchini, A; Binaglia, L

    1996-09-20

    A method for quantitating glycerophosphorylcholine by flow injection analysis is reported in the present paper. Glycerophosphorylcholine phosphodiesterase and choline oxidase, immobilized on controlled porosity glass beads, are packed in a small reactor inserted in a flow injection manifold. When samples containing glycerophosphorylcholine are injected, glycerophosphorylcholine is hydrolyzed into choline and sn-glycerol-3-phosphate. The free choline produced in this reaction is oxidized to betain and hydrogen peroxide. Hydrogen peroxide is detected amperometrically. Quantitation of glycerophosphorylcholine in samples containing choline and phosphorylcholine is obtained inserting ahead of the reactor a small column packed with a mixed bed ion exchange resin. The time needed for each determination does not exceed one minute. The present method, applied to quantitate glycerophosphorylcholine in samples of seminal plasma, gave results comparable with those obtained using the standard enzymatic-spectrophotometric procedure. An alternative procedure, making use of co-immobilized glycerophosphorylcholine phosphodiesterase and glycerol-3-phosphate oxidase for quantitating glycerophosphorylcholine, glycerophosphorylethanolamine and glycerophosphorylserine is also described.

  6. Quantitative characterization of nanoscale polycrystalline magnets with electron magnetic circular dichroism.

    PubMed

    Muto, Shunsuke; Rusz, Ján; Tatsumi, Kazuyoshi; Adam, Roman; Arai, Shigeo; Kocevski, Vancho; Oppeneer, Peter M; Bürgler, Daniel E; Schneider, Claus M

    2014-01-01

    Electron magnetic circular dichroism (EMCD) allows the quantitative, element-selective determination of spin and orbital magnetic moments, similar to its well-established X-ray counterpart, X-ray magnetic circular dichroism (XMCD). As an advantage over XMCD, EMCD measurements are made using transmission electron microscopes, which are routinely operated at sub-nanometre resolution, thereby potentially allowing nanometre magnetic characterization. However, because of the low intensity of the EMCD signal, it has not yet been possible to obtain quantitative information from EMCD signals at the nanoscale. Here we demonstrate a new approach to EMCD measurements that considerably enhances the outreach of the technique. The statistical analysis introduced here yields robust quantitative EMCD signals. Moreover, we demonstrate that quantitative magnetic information can be routinely obtained using electron beams of only a few nanometres in diameter without imposing any restriction regarding the crystalline order of the specimen.

  7. Quantitative and predictive model of kinetic regulation by E. coli TPP riboswitches

    PubMed Central

    Guedich, Sondés; Puffer-Enders, Barbara; Baltzinger, Mireille; Hoffmann, Guillaume; Da Veiga, Cyrielle; Jossinet, Fabrice; Thore, Stéphane; Bec, Guillaume; Ennifar, Eric; Burnouf, Dominique; Dumas, Philippe

    2016-01-01

    ABSTRACT Riboswitches are non-coding elements upstream or downstream of mRNAs that, upon binding of a specific ligand, regulate transcription and/or translation initiation in bacteria, or alternative splicing in plants and fungi. We have studied thiamine pyrophosphate (TPP) riboswitches regulating translation of thiM operon and transcription and translation of thiC operon in E. coli, and that of THIC in the plant A. thaliana. For all, we ascertained an induced-fit mechanism involving initial binding of the TPP followed by a conformational change leading to a higher-affinity complex. The experimental values obtained for all kinetic and thermodynamic parameters of TPP binding imply that the regulation by A. thaliana riboswitch is governed by mass-action law, whereas it is of kinetic nature for the two bacterial riboswitches. Kinetic regulation requires that the RNA polymerase pauses after synthesis of each riboswitch aptamer to leave time for TPP binding, but only when its concentration is sufficient. A quantitative model of regulation highlighted how the pausing time has to be linked to the kinetic rates of initial TPP binding to obtain an ON/OFF switch in the correct concentration range of TPP. We verified the existence of these pauses and the model prediction on their duration. Our analysis also led to quantitative estimates of the respective efficiency of kinetic and thermodynamic regulations, which shows that kinetically regulated riboswitches react more sharply to concentration variation of their ligand than thermodynamically regulated riboswitches. This rationalizes the interest of kinetic regulation and confirms empirical observations that were obtained by numerical simulations. PMID:26932506

  8. Quantitative and predictive model of kinetic regulation by E. coli TPP riboswitches.

    PubMed

    Guedich, Sondés; Puffer-Enders, Barbara; Baltzinger, Mireille; Hoffmann, Guillaume; Da Veiga, Cyrielle; Jossinet, Fabrice; Thore, Stéphane; Bec, Guillaume; Ennifar, Eric; Burnouf, Dominique; Dumas, Philippe

    2016-01-01

    Riboswitches are non-coding elements upstream or downstream of mRNAs that, upon binding of a specific ligand, regulate transcription and/or translation initiation in bacteria, or alternative splicing in plants and fungi. We have studied thiamine pyrophosphate (TPP) riboswitches regulating translation of thiM operon and transcription and translation of thiC operon in E. coli, and that of THIC in the plant A. thaliana. For all, we ascertained an induced-fit mechanism involving initial binding of the TPP followed by a conformational change leading to a higher-affinity complex. The experimental values obtained for all kinetic and thermodynamic parameters of TPP binding imply that the regulation by A. thaliana riboswitch is governed by mass-action law, whereas it is of kinetic nature for the two bacterial riboswitches. Kinetic regulation requires that the RNA polymerase pauses after synthesis of each riboswitch aptamer to leave time for TPP binding, but only when its concentration is sufficient. A quantitative model of regulation highlighted how the pausing time has to be linked to the kinetic rates of initial TPP binding to obtain an ON/OFF switch in the correct concentration range of TPP. We verified the existence of these pauses and the model prediction on their duration. Our analysis also led to quantitative estimates of the respective efficiency of kinetic and thermodynamic regulations, which shows that kinetically regulated riboswitches react more sharply to concentration variation of their ligand than thermodynamically regulated riboswitches. This rationalizes the interest of kinetic regulation and confirms empirical observations that were obtained by numerical simulations.

  9. Measurement of bone marrow lesions by MR imaging in knee osteoarthritis using quantitative segmentation methods--a reliability and sensitivity to change analysis.

    PubMed

    Nielsen, Flemming K; Egund, Niels; Peters, David; Jurik, Anne Grethe

    2014-12-20

    Longitudinal assessment of bone marrow lesions (BMLs) in knee osteoarthritis (KOA) by MRI is usually performed using semi-quantitative grading methods. Quantitative segmentation methods may be more sensitive to detect change over time. The purpose of this study was to evaluate and compare the validity and sensitivity to detect changes of two quantitative MR segmentation methods for measuring BMLs in KOA, one computer assisted (CAS) and one manual (MS) method. Twenty-two patients with KOA confined to the medial femoro-tibial compartment obtained MRI at baseline and follow-up (median 334 days in between). STIR, T1 and fat saturated T1 post-contrast sequences were obtained using a 1.5 T system. The 44 sagittal STIR sequences were assessed independently by two readers for quantification of BML. The signal intensities (SIs) of the normal bone marrow in the lateral femoral condyles and tibial plateaus were used as threshold values. The volume of bone marrow with SIs exceeding the threshold values (BML) was measured in the medial femoral condyle and tibial plateau and related to the total volume of the condyles/plateaus.The 95% limits of agreement at baseline were used to determine the sensitivity to change. The mean threshold values of CAS and MS were almost identical but the absolute and relative BML volumes differed being 1319 mm3/10% and 1828 mm3/15% in the femur and 941 mm3/7% and 2097 mm3/18% in the tibia using CAS and MS, respectively. The BML volumes obtained by CAS and MS were significantly correlated but the tissue changes measured were different. The volume of voxels exceeding the threshold values was measured by CAS whereas MS included intervening voxels with normal SI.The 95% limits of agreement were narrower by CAS than by MS; a significant change of relative BML by CAS was outside the limits of -2.0%-4.7% whereas the limits by MS were -6.9%-8.2%. The BML changed significantly in 13 knees using CAS and in 10 knees by MS. CAS was a reliable method for

  10. FDG-PET Response Prediction in Pediatric Hodgkin's Lymphoma: Impact of Metabolically Defined Tumor Volumes and Individualized SUV Measurements on the Positive Predictive Value.

    PubMed

    Hussien, Amr Elsayed M; Furth, Christian; Schönberger, Stefan; Hundsdoerfer, Patrick; Steffen, Ingo G; Amthauer, Holger; Müller, Hans-Wilhelm; Hautzel, Hubertus

    2015-01-28

    In pediatric Hodgkin's lymphoma (pHL) early response-to-therapy prediction is metabolically assessed by (18)F-FDG PET carrying an excellent negative predictive value (NPV) but an impaired positive predictive value (PPV). Aim of this study was to improve the PPV while keeping the optimal NPV. A comparison of different PET data analyses was performed applying individualized standardized uptake values (SUV), PET-derived metabolic tumor volume (MTV) and the product of both parameters, termed total lesion glycolysis (TLG); One-hundred-eight PET datasets (PET1, n = 54; PET2, n = 54) of 54 children were analysed by visual and semi-quantitative means. SUVmax, SUVmean, MTV and TLG were obtained the results of both PETs and the relative change from PET1 to PET2 (Δ in %) were compared for their capability of identifying responders and non-responders using receiver operating characteristics (ROC)-curves. In consideration of individual variations in noise and contrasts levels all parameters were additionally obtained after threshold correction to lean body mass and background; All semi-quantitative SUV estimates obtained at PET2 were significantly superior to the visual PET2 analysis. However, ΔSUVmax revealed the best results (area under the curve, 0.92; p < 0.001; sensitivity 100%; specificity 85.4%; PPV 46.2%; NPV 100%; accuracy, 87.0%) but was not significantly superior to SUVmax-estimation at PET2 and ΔTLGmax. Likewise, the lean body mass and background individualization of the datasets did not impove the results of the ROC analyses; Sophisticated semi-quantitative PET measures in early response assessment of pHL patients do not perform significantly better than the previously proposed ΔSUVmax. All analytical strategies failed to improve the impaired PPV to a clinically acceptable level while preserving the excellent NPV.

  11. Prognostic value of quantitative sensory testing in low back pain: a systematic review of the literature

    PubMed Central

    Marcuzzi, Anna; Dean, Catherine M; Wrigley, Paul J; Chakiath, Rosemary J; Hush, Julia M

    2016-01-01

    Quantitative sensory testing (QST) measures have recently been shown to predict outcomes in various musculoskeletal and pain conditions. The aim of this systematic review was to summarize the emerging body of evidence investigating the prognostic value of QST measures in people with low back pain (LBP). The protocol for this review was prospectively registered on the International Prospective Register of Systematic Reviews. An electronic search of six databases was conducted from inception to October 2015. Experts in the field were contacted to retrieve additional unpublished data. Studies were included if they were prospective longitudinal in design, assessed at least one QST measure in people with LBP, assessed LBP status at follow-up, and reported the association of QST data with LBP status at follow-up. Statistical pooling of results was not possible due to heterogeneity between studies. Of 6,408 references screened after duplicates removed, three studies were finally included. None of them reported a significant association between the QST measures assessed and the LBP outcome. Three areas at high risk of bias were identified which potentially compromise the validity of these results. Due to the paucity of available studies and the methodological shortcomings identified, it remains unknown whether QST measures are predictive of outcome in LBP. PMID:27660486

  12. Prognostic value of quantitative sensory testing in low back pain: a systematic review of the literature.

    PubMed

    Marcuzzi, Anna; Dean, Catherine M; Wrigley, Paul J; Chakiath, Rosemary J; Hush, Julia M

    2016-01-01

    Quantitative sensory testing (QST) measures have recently been shown to predict outcomes in various musculoskeletal and pain conditions. The aim of this systematic review was to summarize the emerging body of evidence investigating the prognostic value of QST measures in people with low back pain (LBP). The protocol for this review was prospectively registered on the International Prospective Register of Systematic Reviews. An electronic search of six databases was conducted from inception to October 2015. Experts in the field were contacted to retrieve additional unpublished data. Studies were included if they were prospective longitudinal in design, assessed at least one QST measure in people with LBP, assessed LBP status at follow-up, and reported the association of QST data with LBP status at follow-up. Statistical pooling of results was not possible due to heterogeneity between studies. Of 6,408 references screened after duplicates removed, three studies were finally included. None of them reported a significant association between the QST measures assessed and the LBP outcome. Three areas at high risk of bias were identified which potentially compromise the validity of these results. Due to the paucity of available studies and the methodological shortcomings identified, it remains unknown whether QST measures are predictive of outcome in LBP.

  13. Direct and quantitative analysis of underivatized acylcarnitines in serum and whole blood using paper spray mass spectrometry

    PubMed Central

    Yang, Qian; Manicke, Nicholas E.; Wang, He; Petucci, Christopher; Cooks, R. Graham

    2013-01-01

    A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R2>0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests. PMID:22760507

  14. Real-time quantitative polymerase chain reaction analysis of patients with refractory chronic periodontitis.

    PubMed

    Marconcini, Simone; Covani, Ugo; Barone, Antonio; Vittorio, Orazio; Curcio, Michele; Barbuti, Serena; Scatena, Fabrizio; Felli, Lamberto; Nicolini, Claudio

    2011-07-01

    Periodontitis is a complex multifactorial disease and is typically polygenic in origin. Genes play a fundamental part in each biologic process forming complex networks of interactions. However, only some genes have a high number of interactions with other genes in the network and may, therefore, be considered to play an important role. In a preliminary bioinformatic analysis, five genes that showed a higher number of interactions were identified and termed leader genes. In the present study, we use real-time quantitative polymerase chain reaction (PCR) technology to evaluate the expression levels of leader genes in the leukocytes of 10 patients with refractory chronic periodontitis and compare the expression levels with those of the same genes in 24 healthy patients. Blood was collected from 24 healthy human subjects and 10 patients with refractory chronic periodontitis and placed into heparinized blood collection tubes by personnel trained in phlebotomy using a sterile technique. Blood leukocyte cells were immediately lysed by using a kit for total RNA purification from human whole blood. Complementary DNA (cDNA) synthesis was obtained from total RNA and then real-time quantitative PCR was performed. PCR efficiencies were calculated with a relative standard curve derived from a five cDNA dilution series in triplicate that gave regression coefficients >0.98 and efficiencies >96%. The standard curves were obtained using glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and growth factor receptor binding protein 2 (GRB2), casitas B-lineage lymphoma (CBL), nuclear factor-KB1 (NFKB1), and REL-A (gene for transcription factor p65) gene primers and amplified with 1.6, 8, 40, 200, and 1,000 ng/μL total cDNA. Curves obtained for each sample showed a linear relationship between RNA concentrations and the cycle threshold value of real-time quantitative PCR for all genes. Data were expressed as mean ± SE (SEM). The groups were compared to the analysis of variance. A

  15. Racial Differences in Quantitative Measures of Area and Volumetric Breast Density

    PubMed Central

    McCarthy, Anne Marie; Keller, Brad M.; Pantalone, Lauren M.; Hsieh, Meng-Kang; Synnestvedt, Marie; Conant, Emily F.; Armstrong, Katrina; Kontos, Despina

    2016-01-01

    Abstract Background: Increased breast density is a strong risk factor for breast cancer and also decreases the sensitivity of mammographic screening. The purpose of our study was to compare breast density for black and white women using quantitative measures. Methods: Breast density was assessed among 5282 black and 4216 white women screened using digital mammography. Breast Imaging-Reporting and Data System (BI-RADS) density was obtained from radiologists’ reports. Quantitative measures for dense area, area percent density (PD), dense volume, and volume percent density were estimated using validated, automated software. Breast density was categorized as dense or nondense based on BI-RADS categories or based on values above and below the median for quantitative measures. Logistic regression was used to estimate the odds of having dense breasts by race, adjusted for age, body mass index (BMI), age at menarche, menopause status, family history of breast or ovarian cancer, parity and age at first birth, and current hormone replacement therapy (HRT) use. All statistical tests were two-sided. Results: There was a statistically significant interaction of race and BMI on breast density. After accounting for age, BMI, and breast cancer risk factors, black women had statistically significantly greater odds of high breast density across all quantitative measures (eg, PD nonobese odds ratio [OR] = 1.18, 95% confidence interval [CI] = 1.02 to 1.37, P = .03, PD obese OR = 1.26, 95% CI = 1.04 to 1.53, P = .02). There was no statistically significant difference in BI-RADS density by race. Conclusions: After accounting for age, BMI, and other risk factors, black women had higher breast density than white women across all quantitative measures previously associated with breast cancer risk. These results may have implications for risk assessment and screening. PMID:27130893

  16. Quantitative multiplexed proteomics of Taenia solium cysts obtained from the skeletal muscle and central nervous system of pigs

    PubMed Central

    Navarrete-Perea, José; Isasa, Marta; Paulo, Joao A.; Corral-Corral, Ricardo; Flores-Bautista, Jeanette; Hernández-Téllez, Beatriz; Bobes, Raúl J.; Fragoso, Gladis; Sciutto, Edda; Soberón, Xavier; Gygi, Steven P.; Laclette, Juan P.

    2017-01-01

    In human and porcine cysticercosis caused by the tapeworm Taenia solium, the larval stage (cysts) can infest several tissues including the central nervous system (CNS) and the skeletal muscles (SM). The cyst’s proteomics changes associated with the tissue localization in the host tissues have been poorly studied. Quantitative multiplexed proteomics has the power to evaluate global proteome changes in response to different conditions. Here, using a TMT-multiplexed strategy we identified and quantified over 4,200 proteins in cysts obtained from the SM and CNS of pigs, of which 891 were host proteins. To our knowledge, this is the most extensive intermixing of host and parasite proteins reported for tapeworm infections.Several antigens in cysticercosis, i.e., GP50, paramyosin and a calcium-binding protein were enriched in skeletal muscle cysts. Our results suggested the occurrence of tissue-enriched antigen that could be useful in the improvement of the immunodiagnosis for cysticercosis. Using several algorithms for epitope detection, we selected 42 highly antigenic proteins enriched for each tissue localization of the cysts. Taking into account the fold changes and the antigen/epitope contents, we selected 10 proteins and produced synthetic peptides from the best epitopes. Nine peptides were recognized by serum antibodies of cysticercotic pigs, suggesting that those peptides are antigens. Mixtures of peptides derived from SM and CNS cysts yielded better results than mixtures of peptides derived from a single tissue location, however the identification of the ‘optimal’ tissue-enriched antigens remains to be discovered. Through machine learning technologies, we determined that a reliable immunodiagnostic test for porcine cysticercosis required at least five different antigenic determinants. PMID:28945737

  17. Quantitative multiplexed proteomics of Taenia solium cysts obtained from the skeletal muscle and central nervous system of pigs.

    PubMed

    Navarrete-Perea, José; Isasa, Marta; Paulo, Joao A; Corral-Corral, Ricardo; Flores-Bautista, Jeanette; Hernández-Téllez, Beatriz; Bobes, Raúl J; Fragoso, Gladis; Sciutto, Edda; Soberón, Xavier; Gygi, Steven P; Laclette, Juan P

    2017-09-01

    In human and porcine cysticercosis caused by the tapeworm Taenia solium, the larval stage (cysts) can infest several tissues including the central nervous system (CNS) and the skeletal muscles (SM). The cyst's proteomics changes associated with the tissue localization in the host tissues have been poorly studied. Quantitative multiplexed proteomics has the power to evaluate global proteome changes in response to different conditions. Here, using a TMT-multiplexed strategy we identified and quantified over 4,200 proteins in cysts obtained from the SM and CNS of pigs, of which 891 were host proteins. To our knowledge, this is the most extensive intermixing of host and parasite proteins reported for tapeworm infections.Several antigens in cysticercosis, i.e., GP50, paramyosin and a calcium-binding protein were enriched in skeletal muscle cysts. Our results suggested the occurrence of tissue-enriched antigen that could be useful in the improvement of the immunodiagnosis for cysticercosis. Using several algorithms for epitope detection, we selected 42 highly antigenic proteins enriched for each tissue localization of the cysts. Taking into account the fold changes and the antigen/epitope contents, we selected 10 proteins and produced synthetic peptides from the best epitopes. Nine peptides were recognized by serum antibodies of cysticercotic pigs, suggesting that those peptides are antigens. Mixtures of peptides derived from SM and CNS cysts yielded better results than mixtures of peptides derived from a single tissue location, however the identification of the 'optimal' tissue-enriched antigens remains to be discovered. Through machine learning technologies, we determined that a reliable immunodiagnostic test for porcine cysticercosis required at least five different antigenic determinants.

  18. The Xeno-glycomics database (XDB): a relational database of qualitative and quantitative pig glycome repertoire.

    PubMed

    Park, Hae-Min; Park, Ju-Hyeong; Kim, Yoon-Woo; Kim, Kyoung-Jin; Jeong, Hee-Jin; Jang, Kyoung-Soon; Kim, Byung-Gee; Kim, Yun-Gon

    2013-11-15

    In recent years, the improvement of mass spectrometry-based glycomics techniques (i.e. highly sensitive, quantitative and high-throughput analytical tools) has enabled us to obtain a large dataset of glycans. Here we present a database named Xeno-glycomics database (XDB) that contains cell- or tissue-specific pig glycomes analyzed with mass spectrometry-based techniques, including a comprehensive pig glycan information on chemical structures, mass values, types and relative quantities. It was designed as a user-friendly web-based interface that allows users to query the database according to pig tissue/cell types or glycan masses. This database will contribute in providing qualitative and quantitative information on glycomes characterized from various pig cells/organs in xenotransplantation and might eventually provide new targets in the α1,3-galactosyltransferase gene-knock out pigs era. The database can be accessed on the web at http://bioinformatics.snu.ac.kr/xdb.

  19. Comparison of the T2-star Values of Placentas Obtained from Pre-eclamptic Patients with Those of a Control Group: an Ex-vivo Magnetic Resonance Imaging Study.

    PubMed

    Yurttutan, Nursel; Bakacak, Murat; Kızıldağ, Betül

    2017-09-29

    Endotel dysfunction, vasoconstriction, and oxidative stress are described in the pathophysiology of pre-eclampsia, but its aetiology has not been revealed clearly. To examine whether there is a difference between the placentas of pre-eclamptic pregnant women and those of a control group in terms of their T2 star values. Case-control study. Twenty patients diagnosed with pre-eclampsia and 22 healthy controls were included in this study. The placentas obtained after births performed via Caesarean section were taken into the magnetic resonance imaging area in plastic bags within the first postnatal hour, and imaging was performed via modified DIXON-Quant sequence. Average values were obtained by performing T2 star measurements from four localisations on the placentas. T2 star values measured in the placentas of the control group were found to be significantly lower than those in the pre-eclampsia group (p<0.01). While the mean T2 star value in the pre-eclamptic group was found to be 37.48 ms (standard deviation ± 11.3), this value was 28.74 (standard deviation ± 8.08) in the control group. The cut-off value for the T2 star value, maximising the accuracy of diagnosis, was 28.59 ms (area under curve: 0.741; 95% confidence interval: 0.592-0.890); sensitivity and specificity were 70% and 63.6%, respectively. This study, the T2 star value, which is an indicator of iron amount, was found to be significantly lower in the control group than in the pre-eclampsia group. This may be related to the reduction in blood flow to the placenta due to endothelial dysfunction and vasoconstriction, which are important in pre-eclampsia pathophysiology.

  20. Correlation of Lactic Acid and Base Deficit Values Obtained From Arterial and Peripheral Venous Samples in a Pediatric Population During Intraoperative Care.

    PubMed

    Bordes, Brianne M; Walia, Hina; Sebastian, Roby; Martin, David; Tumin, Dmitry; Tobias, Joseph D

    2017-12-01

    Lactic acid and base deficit (BD) values are frequently monitored in the intensive care unit and operating room setting to evaluate oxygenation, ventilation, cardiac output, and peripheral perfusion. Although generally obtained from an arterial cannula, such access may not always be available. The current study prospectively investigates the correlation of arterial and peripheral venous values of BD and lactic acid. The study cohort included 48 patients. Arterial BD values ranged from -8 to 4 mEq/L and peripheral venous BD values ranged from -8 to 4 mEq/L. Arterial lactic acid values ranged from 0.36 to 2.45 μmol/L and peripheral venous lactic acid values ranged from 0.38 to 4 μmol/L. The arterial BD (-0.4 ± 2.2 mEq/L) was not significantly different from the peripheral venous BD (-0.6 ± 2.2 mEq/L). The arterial lactic acid (1.0 ± 0.5 μmol/L) was not significantly different from the peripheral venous lactic acid (1.1 ± 0.6 μmol/L). Pearson correlation coefficients demonstrated a very high correlation between arterial and peripheral venous BD ( r = .88, P < .001) and between arterial and peripheral venous lactic acid ( r = .67, P < .001). Bland-Altman plots of both pairs of measures showed that the majority of observations fell within the 95% limits of agreement. Least-squares regression indicated that a 1-unit increase in arterial BD corresponded to a 0.9-unit increase in peripheral venous BD (95% confidence interval [CI]: 0.7-1.0; P < .001) and a 1-unit increase in arterial lactic acid corresponded to a 0.9-unit increase in peripheral venous lactic acid (95% CI: 0.6-1.2; P < .001). These data demonstrate that there is a clinically useful correlation between arterial and peripheral venous lactic acid and BD values.

  1. Multisource image fusion method using support value transform.

    PubMed

    Zheng, Sheng; Shi, Wen-Zhong; Liu, Jian; Zhu, Guang-Xi; Tian, Jin-Wen

    2007-07-01

    With the development of numerous imaging sensors, many images can be simultaneously pictured by various sensors. However, there are many scenarios where no one sensor can give the complete picture. Image fusion is an important approach to solve this problem and produces a single image which preserves all relevant information from a set of different sensors. In this paper, we proposed a new image fusion method using the support value transform, which uses the support value to represent the salient features of image. This is based on the fact that, in support vector machines (SVMs), the data with larger support values have a physical meaning in the sense that they reveal relative more importance of the data points for contributing to the SVM model. The mapped least squares SVM (mapped LS-SVM) is used to efficiently compute the support values of image. The support value analysis is developed by using a series of multiscale support value filters, which are obtained by filling zeros in the basic support value filter deduced from the mapped LS-SVM to match the resolution of the desired level. Compared with the widely used image fusion methods, such as the Laplacian pyramid, discrete wavelet transform methods, the proposed method is an undecimated transform-based approach. The fusion experiments are undertaken on multisource images. The results demonstrate that the proposed approach is effective and is superior to the conventional image fusion methods in terms of the pertained quantitative fusion evaluation indexes, such as quality of visual information (Q(AB/F)), the mutual information, etc.

  2. Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Soyoung

    Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanelmore » of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between

  3. Quantitation of tr-cinnamaldehyde, safrole and myristicin in cola-flavoured soft drinks to improve the assessment of their dietary exposure.

    PubMed

    Raffo, Antonio; D'Aloise, Antonio; Magrì, Antonio L; Leclercq, Catherine

    2013-09-01

    Quantitation of tr-cinnamaldehyde, safrole and myristicin was carried out in 70 samples of cola-flavoured soft drinks purchased in eight European countries with the purpose of assessing the variability in the levels of these substances. Results indicated a limited variability in the content of the three substances: the ratio between the 90th and the 10th percentile concentration amounted to 21, 6 and 13 for tr-cinnamaldehyde, safrole and myristicin, respectively. The uncertainty in the assessment of dietary exposure to these substances due to the variability of their level in cola-flavoured drinks was low. Based on these analytical data and on refined food consumption data, estimates of exposure to safrole associated to cola drink consumption, along with Margin of Exposure (MOE) values, were obtained. For high consumers of cola-flavoured soft drinks in certain age groups, within some European countries, MOE values lower than 10,000 resulted, MOE values of 10,000 or higher having been stated by the EFSA as a quantitative criterion to identify low concern from a public health point of view and low priority for risk management actions. The lowest MOE values, from 1900 to 3000, were observed for children and teen agers in the United Kingdom and Ireland. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Quantitative analysis of multiple high-resolution mass spectrometry images using chemometric methods: quantitation of chlordecone in mouse liver.

    PubMed

    Mohammadi, Saeedeh; Parastar, Hadi

    2018-05-15

    In this work, a chemometrics-based strategy is developed for quantitative mass spectrometry imaging (MSI). In this regard, quantification of chlordecone as a carcinogenic organochlorinated pesticide (C10Cll0O) in mouse liver using the matrix-assisted laser desorption ionization MSI (MALDI-MSI) method is used as a case study. The MSI datasets corresponded to 1, 5 and 10 days of mouse exposure to the standard chlordecone in the quantity range of 0 to 450 μg g-1. The binning approach in the m/z direction is used to group high resolution m/z values and to reduce the big data size. To consider the effect of bin size on the quality of results, three different bin sizes of 0.25, 0.5 and 1.0 were chosen. Afterwards, three-way MSI data arrays (two spatial and one m/z dimensions) for seven standards and four unknown samples were column-wise augmented with m/z values as the common mode. Then, these datasets were analyzed using multivariate curve resolution-alternating least squares (MCR-ALS) using proper constraints. The resolved mass spectra were used for identification of chlordecone in the presence of a complex background and interference. Additionally, the augmented spatial profiles were post-processed and 2D images for each component were obtained in calibration and unknown samples. The sum of these profiles was utilized to set the calibration curve and to obtain the analytical figures of merit (AFOMs). Inspection of the results showed that the lower bin size (i.e., 0.25) provides more accurate results. Finally, the obtained results by MCR for three datasets were compared with those of gas chromatography-mass spectrometry (GC-MS) and MALDI-MSI. The results showed that the MCR-assisted method gives a higher amount of chlordecone than MALDI-MSI and a lower amount than GC-MS. It is concluded that a combination of chemometric methods with MSI can be considered as an alternative way for MSI quantification.

  5. Preoperative Cerebral Oxygen Extraction Fraction Imaging Generated from 7T MR Quantitative Susceptibility Mapping Predicts Development of Cerebral Hyperperfusion following Carotid Endarterectomy.

    PubMed

    Nomura, J-I; Uwano, I; Sasaki, M; Kudo, K; Yamashita, F; Ito, K; Fujiwara, S; Kobayashi, M; Ogasawara, K

    2017-12-01

    Preoperative hemodynamic impairment in the affected cerebral hemisphere is associated with the development of cerebral hyperperfusion following carotid endarterectomy. Cerebral oxygen extraction fraction images generated from 7T MR quantitative susceptibility mapping correlate with oxygen extraction fraction images on positron-emission tomography. The present study aimed to determine whether preoperative oxygen extraction fraction imaging generated from 7T MR quantitative susceptibility mapping could identify patients at risk for cerebral hyperperfusion following carotid endarterectomy. Seventy-seven patients with unilateral internal carotid artery stenosis (≥70%) underwent preoperative 3D T2*-weighted imaging using a multiple dipole-inversion algorithm with a 7T MR imager. Quantitative susceptibility mapping images were then obtained, and oxygen extraction fraction maps were generated. Quantitative brain perfusion single-photon emission CT was also performed before and immediately after carotid endarterectomy. ROIs were automatically placed in the bilateral middle cerebral artery territories in all images using a 3D stereotactic ROI template, and affected-to-contralateral ratios in the ROIs were calculated on quantitative susceptibility mapping-oxygen extraction fraction images. Ten patients (13%) showed post-carotid endarterectomy hyperperfusion (cerebral blood flow increases of ≥100% compared with preoperative values in the ROIs on brain perfusion SPECT). Multivariate analysis showed that a high quantitative susceptibility mapping-oxygen extraction fraction ratio was significantly associated with the development of post-carotid endarterectomy hyperperfusion (95% confidence interval, 33.5-249.7; P = .002). Sensitivity, specificity, and positive- and negative-predictive values of the quantitative susceptibility mapping-oxygen extraction fraction ratio for the prediction of the development of post-carotid endarterectomy hyperperfusion were 90%, 84%, 45%, and 98

  6. Using the Climbing Drum Peel (CDP) Test to Obtain a G(sub IC) value for Core/Facesheet Bonds

    NASA Technical Reports Server (NTRS)

    Nettles, A. T.; Gregory, Elizabeth D.; Jackson, Justin R.

    2006-01-01

    A method of measuring the Mode I fracture toughness of core/facesheet bonds in sandwich Structures is desired, particularly with the widespread use of models that need this data as input. This study examined if a critical strain energy release rate, G(sub IC), can be obtained from the climbing drum peel (CDP) test. The CDP test is relatively simple to perform and does not rely on measuring small crack lengths such as required by the double cantilever beam (DCB) test. Simple energy methods were used to calculate G(sub IC) from CDP test data on composite facesheets bonded to a honeycomb core. Facesheet thicknesses from 2 to 5 plies were tested to examine the upper and lower bounds on facesheet thickness requirements. Results from the study suggest that the CDP test, with certain provisions, can be used to find the GIG value of a core/facesheet bond.

  7. MR Imaging of the Prostate and Adjacent Anatomic Structures before, during, and after Ejaculation: Qualitative and Quantitative Evaluation1

    PubMed Central

    Medved, Milica; Sammet, Steffen; Yousuf, Ambereen; Oto, Aytekin

    2015-01-01

    Purpose To determine the possibility of obtaining high-quality magnetic resonance (MR) images before, during, and immediately after ejaculation and detecting measurable changes in quantitative MR imaging parameters after ejaculation. Materials and Methods In this prospective, institutional review board–approved, HIPAA-compliant study, eight young healthy volunteers (median age, 22.5 years), after providing informed consent, underwent MR imaging while masturbating to the point of ejaculation. A 1.5-T MR imaging unit was used, with an eight-channel surface coil and a dynamic single-shot fast spin-echo sequence. In addition, a quantitative MR imaging protocol that allowed calculation of T1, T2, and apparent diffusion coefficient (ADC) values was applied before and after ejaculation. Volumes of the prostate and seminal vesicles (SV) were calculated by using whole-volume segmentation on T2-weighted images, both before and after ejaculation. Pre- and postejaculation changes in quantitative MR parameters and measured volumes were evaluated by using the Wilcoxon signed rank test with Bonferroni adjustment. Results There was no significant change in prostate volumes on pre- and postejaculation images, while the SV contracted by 41% on average (median, 44.5%; P = .004). No changes before and after ejaculation were observed in T1 values or in T2 and ADC values in the central gland, while T2 and ADC values were significantly reduced in the peripheral zone by 12% and 14%, respectively (median, 13% and 14.5%, respectively; P = .004). Conclusion Successful dynamic MR imaging of ejaculation events and the ability to visualize internal sphincter closure, passage of ejaculate, and significant changes in SV volumes were demonstrated. Significant changes in peripheral zone T2 and ADC values were observed. PMID:24495265

  8. Protocol for obtaining platelet-rich plasma (PRP), platelet-poor plasma (PPP), and thrombin for autologous use.

    PubMed

    Franco, Diogo; Franco, Talita; Schettino, Angélica Maria; Filho, João Medeiros Tavares; Vendramin, Fabiel Spani

    2012-10-01

    Plasma has been widely studied and used in many different situations to speed up healing with better tissue adherence and hemostasis. Research projects are now attempting to isolate platelet-rich plasma (PRP) and platelet-poor plasma (PPP), making better use of their properties, particularly during operations and for wounds that are slow to heal. In view of the wide diversity of industrial machines and extraction protocols, together with the variety of industrially produced biologic glues, this article suggests an option for obtaining PRP, PPP, and human thrombin for autologous use. A way of obtaining PRP, PPP, and thrombin is reproduced through a protocol defined and established by the authors. Autologous thrombin and plasma were obtained through the collection and successive centrifugation of ten whole blood samples, until the desired hemocomponents were isolated, followed by quantitative and qualitative analyses of the elements obtained. The mean platelet concentration obtained was 6.03 × 10(8) platelets/ml, with a mean thrombin concentration of 33.54 nM, both values compatible with reports in the literature when different protocols are applied. The protocol described is a good option for the preparation and application of PRP, PPP, and autologous thrombin, particularly as they can be obtained simultaneously, eliminating the possibilities of viral contamination and allergic reactions. Moreover, the cost of this procedure is low, it is easy to perform, and replicable. This journal requires that authors assign a level of evidence to each article.

  9. [The use of the deuterated internal standard for morphine quantitation for the purpose of doping control by gas chromatography with mass-selective detection].

    PubMed

    Savel'eva, N B; Bykovskaia, N Iu; Dikunets, M A; Bolotov, S L; Rodchenkov, G M

    2010-01-01

    The objective of this study was to demonstrate the possibility to use deuterated compounds as internal standards for the quantitative analysis of morphine by gas chromatography with mass-selective detection for the purpose of doping control. The paper is focused on the problems associated with the use of deuterated morphine-D3 as the internal standard. Quantitative characteristics of the calibration dependence thus documented are presented along with uncertainty values obtained in the measurements with the use of deuterated morphine-D6. An approach to the assessment of method bias associated with the application of morphine-D6 as the deuterated internal standard is described.

  10. Quantitative angle-insensitive flow measurement using relative standard deviation OCT

    NASA Astrophysics Data System (ADS)

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-01

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo.

  11. Quantitative angle-insensitive flow measurement using relative standard deviation OCT.

    PubMed

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-30

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .

  12. Semi-quantitative analysis of salivary gland scintigraphy in Sjögren's syndrome diagnosis: a first-line tool.

    PubMed

    Angusti, Tiziana; Pilati, Emanuela; Parente, Antonella; Carignola, Renato; Manfredi, Matteo; Cauda, Simona; Pizzigati, Elena; Dubreuil, Julien; Giammarile, Francesco; Podio, Valerio; Skanjeti, Andrea

    2017-09-01

    The aim of this study was the assessment of semi-quantified salivary gland dynamic scintigraphy (SGdS) parameters independently and in an integrated way in order to predict primary Sjögren's syndrome (pSS). Forty-six consecutive patients (41 females; age 61 ± 11 years) with sicca syndrome were studied by SGdS after injection of 200 MBq of pertechnetate. In sixteen patients, pSS was diagnosed, according to American-European Consensus Group criteria (AECGc). Semi-quantitative parameters (uptake (UP) and excretion fraction (EF)) were obtained for each gland. ROC curves were used to determine the best cut-off value. The area under the curve (AUC) was used to estimate the accuracy of each semi-quantitative analysis. To assess the correlation between scintigraphic results and disease severity, semi-quantitative parameters were plotted versus Sjögren's syndrome disease activity index (ESSDAI). A nomogram was built to perform an integrated evaluation of all the scintigraphic semi-quantitative data. Both UP and EF of salivary glands were significantly lower in pSS patients compared to those in non-pSS (p < 0.001). ROC curve showed significantly large AUC for both the parameters (p < 0.05). Parotid UP and submandibular EF, assessed by univariated and multivariate logistic regression, showed a significant and independent correlation with pSS diagnosis (p value <0.05). No correlation was found between SGdS semi-quantitative parameters and ESSDAI. The proposed nomogram accuracy was 87%. SGdS is an accurate and reproducible tool for the diagnosis of pSS. ESSDAI was not shown to be correlated with SGdS data. SGdS should be the first-line imaging technique in patients with suspected pSS.

  13. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    NASA Astrophysics Data System (ADS)

    Chakraborty, Monisha; Ghosh, Dipak

    2017-12-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  14. Quantitative Assessment of Arrhythmia Using Non-linear Approach: A Non-invasive Prognostic Tool

    NASA Astrophysics Data System (ADS)

    Chakraborty, Monisha; Ghosh, Dipak

    2018-04-01

    Accurate prognostic tool to identify severity of Arrhythmia is yet to be investigated, owing to the complexity of the ECG signal. In this paper, we have shown that quantitative assessment of Arrhythmia is possible using non-linear technique based on "Hurst Rescaled Range Analysis". Although the concept of applying "non-linearity" for studying various cardiac dysfunctions is not entirely new, the novel objective of this paper is to identify the severity of the disease, monitoring of different medicine and their dose, and also to assess the efficiency of different medicine. The approach presented in this work is simple which in turn will help doctors in efficient disease management. In this work, Arrhythmia ECG time series are collected from MIT-BIH database. Normal ECG time series are acquired using POLYPARA system. Both time series are analyzed in thelight of non-linear approach following the method "Rescaled Range Analysis". The quantitative parameter, "Fractal Dimension" (D) is obtained from both types of time series. The major finding is that Arrhythmia ECG poses lower values of D as compared to normal. Further, this information can be used to access the severity of Arrhythmia quantitatively, which is a new direction of prognosis as well as adequate software may be developed for the use of medical practice.

  15. Added value of experts' knowledge to improve a quantitative microbial exposure assessment model--Application to aseptic-UHT food products.

    PubMed

    Pujol, Laure; Johnson, Nicholas Brian; Magras, Catherine; Albert, Isabelle; Membré, Jeanne-Marie

    2015-10-15

    In a previous study, a quantitative microbial exposure assessment (QMEA) model applied to an aseptic-UHT food process was developed [Pujol, L., Albert, I., Magras, C., Johnson, N. B., Membré, J. M. Probabilistic exposure assessment model to estimate aseptic UHT product failure rate. 2015 International Journal of Food Microbiology. 192, 124-141]. It quantified Sterility Failure Rate (SFR) associated with Bacillus cereus and Geobacillus stearothermophilus per process module (nine modules in total from raw material reception to end-product storage). Previously, the probabilistic model inputs were set by experts (using knowledge and in-house data). However, only the variability dimension was taken into account. The model was then improved using expert elicitation knowledge in two ways. First, the model was refined by adding the uncertainty dimension to the probabilistic inputs, enabling to set a second order Monte Carlo analysis. The eight following inputs, and their impact on SFR, are presented in detail in this present study: D-value for each bacteria of interest (B. cereus and G. stearothermophilus) associated with the inactivation model for the UHT treatment step, i.e., two inputs; log reduction (decimal reduction) number associated with the inactivation model for the packaging sterilization step for each bacterium and each part of the packaging (product container and sealing component), i.e., four inputs; and bacterial spore air load of the aseptic tank and the filler cabinet rooms, i.e., two inputs. Second, the model was improved by leveraging expert knowledge to develop further the existing model. The proportion of bacteria in the product which settled on surface of pipes (between the UHT treatment and the aseptic tank on one hand, and between the aseptic tank and the filler cabinet on the other hand) leading to a possible biofilm formation for each bacterium, was better characterized. It was modeled as a function of the hygienic design level of the aseptic

  16. Employee Perceptions and Value of Performance Appraisals

    ERIC Educational Resources Information Center

    Bagnell, Rhea

    2012-01-01

    Performance appraisals traditionally have been studied quantitatively, from the manager's point of view, without considering their value or lack of value to workers. The absence of this information indicates that workers' perceptions and feelings have not always been considered. Therefore, the purpose of this phenomenological study was…

  17. Inculcating Noble Values for Pre-Service Teachers

    ERIC Educational Resources Information Center

    Hasan, Anita Abu; Hamzah, Mohd Isa; Awang, Mohd Mahzan

    2014-01-01

    This study aims to identify the noble values that are being cultivated and practiced in the process of teaching and learning of Ethnic Relations Course for pre-service teachers. Element values investigated including the identity, loyalty, patriotism, tolerance, cooperation and pride as a Malaysian. This quantitative research employs a survey…

  18. Quantitative analysis of comparative genomic hybridization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manoir, S. du; Bentz, M.; Joos, S.

    1995-01-01

    Comparative genomic hybridization (CGH) is a new molecular cytogenetic method for the detection of chromosomal imbalances. Following cohybridization of DNA prepared from a sample to be studied and control DNA to normal metaphase spreads, probes are detected via different fluorochromes. The ratio of the test and control fluorescence intensities along a chromosome reflects the relative copy number of segments of a chromosome in the test genome. Quantitative evaluation of CGH experiments is required for the determination of low copy changes, e.g., monosomy or trisomy, and for the definition of the breakpoints involved in unbalanced rearrangements. In this study, a programmore » for quantitation of CGH preparations is presented. This program is based on the extraction of the fluorescence ratio profile along each chromosome, followed by averaging of individual profiles from several metaphase spreads. Objective parameters critical for quantitative evaluations were tested, and the criteria for selection of suitable CGH preparations are described. The granularity of the chromosome painting and the regional inhomogeneity of fluorescence intensities in metaphase spreads proved to be crucial parameters. The coefficient of variation of the ratio value for chromosomes in balanced state (CVBS) provides a general quality criterion for CGH experiments. Different cutoff levels (thresholds) of average fluorescence ratio values were compared for their specificity and sensitivity with regard to the detection of chromosomal imbalances. 27 refs., 15 figs., 1 tab.« less

  19. 47 CFR 54.615 - Obtaining services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... provided under § 54.621, that the requester cannot obtain toll-free access to an Internet service provider... thing of value; (6) If the service or services are being purchased as part of an aggregated purchase...

  20. Comparison of NDVI fields obtained from different remote sensors

    NASA Astrophysics Data System (ADS)

    Escribano Rodriguez, Juan; Alonso, Carmelo; Tarquis, Ana Maria; Benito, Rosa Maria; Hernandez Díaz-Ambrona, Carlos

    2013-04-01

    Satellite image data have become an important source of information for monitoring vegetation and mapping land cover at several scales. Beside this, the distribution and phenology of vegetation is largely associated with climate, terrain characteristics and human activity. Various vegetation indices have been developed for qualitative and quantitative assessment of vegetation using remote spectral measurements. In particular, sensors with spectral bands in the red (RED) and near-infrared (NIR) lend themselves well to vegetation monitoring and based on them [(NIR - RED) / (NIR + RED)] Normalized Difference Vegetation Index (NDVI) has been widespread used. Given that the characteristics of spectral bands in RED and NIR vary distinctly from sensor to sensor, NDVI values based on data from different instruments will not be directly comparable. The spatial resolution also varies significantly between sensors, as well as within a given scene in the case of wide-angle and oblique sensors. As a result, NDVI values will vary according to combinations of the heterogeneity and scale of terrestrial surfaces and pixel footprint sizes. Therefore, the question arises as to the impact of differences in spectral and spatial resolutions on vegetation indices like the NDVI and their interpretation as a drought index. During 2012 three locations (at Salamanca, Granada and Córdoba) were selected and a periodic pasture monitoring and botanic composition were achieved. Daily precipitation, temperature and monthly soil water content were measurement as well as fresh and dry pasture weight. At the same time, remote sensing images were capture by DEIMOS-1 and MODIS of the chosen places. DEIMOS-1 is based on the concept Microsat-100 from Surrey. It is conceived for obtaining Earth images with a good enough resolution to study the terrestrial vegetation cover (20x20 m), although with a great range of visual field (600 km) in order to obtain those images with high temporal resolution and at a

  1. Discovering the Quantity of Quality: Scoring "Regional Identity" for Quantitative Research

    ERIC Educational Resources Information Center

    Miller, Daniel A.

    2008-01-01

    The variationist paradigm in sociolinguistics is at a disadvantage when dealing with variables that are traditionally treated qualitatively, e.g., "identity". This study essays to level the accuracy and descriptive value of qualitative research in a quantitative setting by rendering such a variable quantitatively accessible. To this end,…

  2. Comparative Performance of Reagents and Platforms for Quantitation of Cytomegalovirus DNA by Digital PCR

    PubMed Central

    Gu, Z.; Sam, S. S.; Sun, Y.; Tang, L.; Pounds, S.; Caliendo, A. M.

    2016-01-01

    A potential benefit of digital PCR is a reduction in result variability across assays and platforms. Three sets of PCR reagents were tested on two digital PCR systems (Bio-Rad and RainDance), using three different sets of PCR reagents for quantitation of cytomegalovirus (CMV). Both commercial quantitative viral standards and 16 patient samples (n = 16) were tested. Quantitative accuracy (compared to nominal values) and variability were determined based on viral standard testing results. Quantitative correlation and variability were assessed with pairwise comparisons across all reagent-platform combinations for clinical plasma sample results. The three reagent sets, when used to assay quantitative standards on the Bio-Rad system, all showed a high degree of accuracy, low variability, and close agreement with one another. When used on the RainDance system, one of the three reagent sets appeared to have a much better correlation to nominal values than did the other two. Quantitative results for patient samples showed good correlation in most pairwise comparisons, with some showing poorer correlations when testing samples with low viral loads. Digital PCR is a robust method for measuring CMV viral load. Some degree of result variation may be seen, depending on platform and reagents used; this variation appears to be greater in samples with low viral load values. PMID:27535685

  3. Quantitative measurements of in-cylinder gas composition in a controlled auto-ignition combustion engine

    NASA Astrophysics Data System (ADS)

    Zhao, H.; Zhang, S.

    2008-01-01

    One of the most effective means to achieve controlled auto-ignition (CAI) combustion in a gasoline engine is by the residual gas trapping method. The amount of residual gas and mixture composition have significant effects on the subsequent combustion process and engine emissions. In order to obtain quantitative measurements of in-cylinder residual gas concentration and air/fuel ratio, a spontaneous Raman scattering (SRS) system has been developed recently. The optimized optical SRS setups are presented and discussed. The temperature effect on the SRS measurement is considered and a method has been developed to correct for the overestimated values due to the temperature effect. Simultaneous measurements of O2, H2O, CO2 and fuel were obtained throughout the intake, compression, combustion and expansion strokes. It shows that the SRS can provide valuable data on this process in a CAI combustion engine.

  4. WE-G-18C-02: Estimation of Optimal B-Value Set for Obtaining Apparent Diffusion Coefficient Free From Perfusion in Non-Small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karki, K; Hugo, G; Ford, J

    2014-06-15

    Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADC IVIM) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm andmore » 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADC IVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADC IVIM, perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADC IVIM(p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADC IVIM, respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADC IVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets (250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2

  5. Optimization of Diamond Nucleic Acid Dye for quantitative PCR.

    PubMed

    Haines, Alicia M; Tobe, Shanan S; Linacre, Adrian

    2016-10-01

    Here, we evaluate Diamond Nucleic Acid Dye (DD) for use in quantitative PCR (qPCR) applications. Although DD is a commercially available stain for detection of DNA separated by gel electrophoresis, its use as a detection dye in qPCR has yet to be described. To determine if DD can be used in qPCR, we investigated its inhibitory effects on qPCR at concentrations ranging 0.1-2.5×. Serial dilution of DNA was used to determine the efficiency, sensitivity, and linearity of DD-generated qPCR data in comparison to other commonly used fluorescent dyes such as SYBR Green (SG), EvaGreen (EG), and BRYT Green (BG). DD was found to be comparable with other dyes for qPCR applications, with an R2 value >0.9 and an efficiency of 0.83. Mitochondrial DNA (mtDNA) target signals were successfully produced by DD over a DNA dilution range of ~28 ng- 0.28 pg, demonstrating comparable sensitivity to the other dyes investigated. Cq values obtained using DD were lower than those using EG by almost 7 cycles. We conclude that Diamond Nucleic Acid Dye is a cheaper, less toxic alternative for qPCR applications.

  6. Quantitative Muscle Ultrasonography in Carpal Tunnel Syndrome.

    PubMed

    Lee, Hyewon; Jee, Sungju; Park, Soo Ho; Ahn, Seung-Chan; Im, Juneho; Sohn, Min Kyun

    2016-12-01

    To assess the reliability of quantitative muscle ultrasonography (US) in healthy subjects and to evaluate the correlation between quantitative muscle US findings and electrodiagnostic study results in patients with carpal tunnel syndrome (CTS). The clinical significance of quantitative muscle US in CTS was also assessed. Twenty patients with CTS and 20 age-matched healthy volunteers were recruited. All control and CTS subjects underwent a bilateral median and ulnar nerve conduction study (NCS) and quantitative muscle US. Transverse US images of the abductor pollicis brevis (APB) and abductor digiti minimi (ADM) were obtained to measure muscle cross-sectional area (CSA), thickness, and echo intensity (EI). EI was determined using computer-assisted, grayscale analysis. Inter-rater and intra-rater reliability for quantitative muscle US in control subjects, and differences in muscle thickness, CSA, and EI between the CTS patient and control groups were analyzed. Relationships between quantitative US parameters and electrodiagnostic study results were evaluated. Quantitative muscle US had high inter-rater and intra-rater reliability in the control group. Muscle thickness and CSA were significantly decreased, and EI was significantly increased in the APB of the CTS group (all p<0.05). EI demonstrated a significant positive correlation with latency of the median motor and sensory NCS in CTS patients (p<0.05). These findings suggest that quantitative muscle US parameters may be useful for detecting muscle changes in CTS. Further study involving patients with other neuromuscular diseases is needed to evaluate peripheral muscle change using quantitative muscle US.

  7. Quantitative analysis of arm movement smoothness

    NASA Astrophysics Data System (ADS)

    Szczesna, Agnieszka; Błaszczyszyn, Monika

    2017-07-01

    The paper deals with the problem of motion data quantitative smoothness analysis. We investigated values of movement unit, fluidity and jerk for healthy and paralyzed arm of patients with hemiparesis after stroke. Patients were performing drinking task. To validate the approach, movement of 24 patients were captured using optical motion capture system.

  8. Smile line assessment comparing quantitative measurement and visual estimation.

    PubMed

    Van der Geld, Pieter; Oosterveld, Paul; Schols, Jan; Kuijpers-Jagtman, Anne Marie

    2011-02-01

    Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation according to a standard categorization are more practical for regular diagnostics. Our objective in this study was to compare 2 semiquantitative methods with quantitative measurements for reliability and agreement. The faces of 122 male participants were individually registered by using digital videography. Spontaneous and posed smiles were captured. On the records, maxillary lip line heights and tooth display were digitally measured on each tooth and also visually estimated according to 3-grade and 4-grade scales. Two raters were involved. An error analysis was performed. Reliability was established with kappa statistics. Interexaminer and intraexaminer reliability values were high, with median kappa values from 0.79 to 0.88. Agreement of the 3-grade scale estimation with quantitative measurement showed higher median kappa values (0.76) than the 4-grade scale estimation (0.66). Differentiating high and gummy smile lines (4-grade scale) resulted in greater inaccuracies. The estimation of a high, average, or low smile line for each tooth showed high reliability close to quantitative measurements. Smile line analysis can be performed reliably with a 3-grade scale (visual) semiquantitative estimation. For a more comprehensive diagnosis, additional measuring is proposed, especially in patients with disproportional gingival display. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  9. A Quantitative Needs Assessment Technique for Cross-Cultural Work Adjustment Training.

    ERIC Educational Resources Information Center

    Selmer, Lyn

    2000-01-01

    A study of 67 Swedish expatriate bosses and 104 local Hong Kong middle managers tested a quantitative needs assessment technique measuring work values. Two-thirds of middle managers' work values were not correctly estimated by their bosses, especially instrumental values (pay, benefits, security, working hours and conditions), indicating a need…

  10. An electronic portfolio for quantitative assessment of surgical skills in undergraduate medical education.

    PubMed

    Sánchez Gómez, Serafín; Ostos, Elisa María Cabot; Solano, Juan Manuel Maza; Salado, Tomás Francisco Herrero

    2013-05-06

    We evaluated a newly designed electronic portfolio (e-Portfolio) that provided quantitative evaluation of surgical skills. Medical students at the University of Seville used the e-Portfolio on a voluntary basis for evaluation of their performance in undergraduate surgical subjects. Our new web-based e-Portfolio was designed to evaluate surgical practical knowledge and skills targets. Students recorded each activity on a form, attached evidence, and added their reflections. Students self-assessed their practical knowledge using qualitative criteria (yes/no), and graded their skills according to complexity (basic/advanced) and participation (observer/assistant/independent). A numerical value was assigned to each activity, and the values of all activities were summated to obtain the total score. The application automatically displayed quantitative feedback. We performed qualitative evaluation of the perceived usefulness of the e-Portfolio and quantitative evaluation of the targets achieved. Thirty-seven of 112 students (33%) used the e-Portfolio, of which 87% reported that they understood the methodology of the portfolio. All students reported an improved understanding of their learning objectives resulting from the numerical visualization of progress, all students reported that the quantitative feedback encouraged their learning, and 79% of students felt that their teachers were more available because they were using the e-Portfolio. Only 51.3% of students reported that the reflective aspects of learning were useful. Individual students achieved a maximum of 65% of the total targets and 87% of the skills targets. The mean total score was 345 ± 38 points. For basic skills, 92% of students achieved the maximum score for participation as an independent operator, and all achieved the maximum scores for participation as an observer and assistant. For complex skills, 62% of students achieved the maximum score for participation as an independent operator, and 98% achieved

  11. Quantitative reactive modeling and verification.

    PubMed

    Henzinger, Thomas A

    Formal verification aims to improve the quality of software by detecting errors before they do harm. At the basis of formal verification is the logical notion of correctness , which purports to capture whether or not a program behaves as desired. We suggest that the boolean partition of software into correct and incorrect programs falls short of the practical need to assess the behavior of software in a more nuanced fashion against multiple criteria. We therefore propose to introduce quantitative fitness measures for programs, specifically for measuring the function, performance, and robustness of reactive programs such as concurrent processes. This article describes the goals of the ERC Advanced Investigator Project QUAREM. The project aims to build and evaluate a theory of quantitative fitness measures for reactive models. Such a theory must strive to obtain quantitative generalizations of the paradigms that have been success stories in qualitative reactive modeling, such as compositionality, property-preserving abstraction and abstraction refinement, model checking, and synthesis. The theory will be evaluated not only in the context of software and hardware engineering, but also in the context of systems biology. In particular, we will use the quantitative reactive models and fitness measures developed in this project for testing hypotheses about the mechanisms behind data from biological experiments.

  12. Quantitative T2 mapping evaluation for articular cartilage lesions in a rabbit model of anterior cruciate ligament transection osteoarthritis.

    PubMed

    Wei, Zheng-mao; Du, Xiang-ke; Huo, Tian-long; Li, Xu-bin; Quan, Guang-nan; Li, Tian-ran; Cheng, Jin; Zhang, Wei-tao

    2012-03-01

    Quantitative T2 mapping has been a widely used method for the evaluation of pathological cartilage properties, and the histological assessment system of osteoarthritis in the rabbit has been published recently. The aim of the study was to investigate the effectiveness of quantitative T2 mapping evaluation for articular cartilage lesions of a rabbit model of anterior cruciate ligament transection (ACLT) osteoarthritis. Twenty New Zealand White (NZW) rabbits were divided into ACLT surgical group and sham operated group equally. The anterior cruciate ligaments of the rabbits in ACLT group were transected, while the joints were closed intactly in sham operated group. Magnetic resonance (MR) examinations were performed on 3.0T MR unit at week 0, week 6, and week 12. T2 values were computed on GE ADW4.3 workstation. All rabbits were killed at week 13, and left knees were stained with Haematoxylin and Eosin. Semiquantitative histological grading was obtained according to the osteoarthritis cartilage histopathology assessment system. Computerized image analysis was performed to quantitate the immunostained collagen type II. The average MR T2 value of whole left knee cartilage in ACLT surgical group ((29.05±12.01) ms) was significantly higher than that in sham operated group ((24.52±7.97) ms) (P=0.024) at week 6. The average T2 value increased to (32.18±12.79) ms in ACLT group at week 12, but remained near the baseline level ((27.66±8.08) ms) in the sham operated group (P=0.03). The cartilage lesion level of left knee in ACLT group was significantly increased at week 6 (P=0.005) and week 12 (P<0.001). T2 values had positive correlation with histological grading scores, but inverse correlation with optical densities (OD) of type II collagen. This study demonstrated the reliability and practicability of quantitative T2 mapping for the cartilage injury of rabbit ACLT osteoarthritis model.

  13. MR morphology of triangular fibrocartilage complex: correlation with quantitative MR and biomechanical properties.

    PubMed

    Bae, Won C; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda; Chung, Christine B

    2016-04-01

    To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high-resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Five cadaveric wrists (22-70 years) were imaged at 3 T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques.

  14. MR Morphology of Triangular Fibrocartilage Complex: Correlation with Quantitative MR and Biomechanical Properties

    PubMed Central

    Bae, Won C.; Ruangchaijatuporn, Thumanoon; Chang, Eric Y; Biswas, Reni; Du, Jiang; Statum, Sheronda

    2016-01-01

    Objective To evaluate pathology of the triangular fibrocartilage complex (TFCC) using high resolution morphologic magnetic resonance (MR) imaging, and compare with quantitative MR and biomechanical properties. Materials and Methods Five cadaveric wrists (22 to 70 yrs) were imaged at 3T using morphologic (proton density weighted spin echo, PD FS, and 3D spoiled gradient echo, 3D SPGR) and quantitative MR sequences to determine T2 and T1rho properties. In eight geographic regions, morphology of TFC disc and laminae were evaluated for pathology and quantitative MR values. Samples were disarticulated and biomechanical indentation testing was performed on the distal surface of the TFC disc. Results On morphologic PD SE images, TFC disc pathology included degeneration and tears, while that of the laminae included degeneration, degeneration with superimposed tear, mucinous transformation, and globular calcification. Punctate calcifications were highly visible on 3D SPGR images and found only in pathologic regions. Disc pathology occurred more frequently in proximal regions of the disc than distal regions. Quantitative MR values were lowest in normal samples, and generally higher in pathologic regions. Biomechanical testing demonstrated an inverse relationship, with indentation modulus being high in normal regions with low MR values. The laminae studied were mostly pathologic, and additional normal samples are needed to discern quantitative changes. Conclusion These results show technical feasibility of morphologic MR, quantitative MR, and biomechanical techniques to characterize pathology of the TFCC. Quantitative MRI may be a suitable surrogate marker of soft tissue mechanical properties, and a useful adjunct to conventional morphologic MR techniques. PMID:26691643

  15. Predictive values of semi-quantitative procalcitonin test and common biomarkers for the clinical outcomes of community-acquired pneumonia.

    PubMed

    Ugajin, Motoi; Yamaki, Kenichi; Hirasawa, Natsuko; Yagi, Takeo

    2014-04-01

    The semi-quantitative serum procalcitonin test (Brahms PCT-Q) is available conveniently in clinical practice. However, there are few data on the relationship between results for this semi-quantitative procalcitonin test and clinical outcomes of community-acquired pneumonia (CAP). We investigated the usefulness of this procalcitonin test for predicting the clinical outcomes of CAP in comparison with severity scoring systems and the blood urea nitrogen/serum albumin (B/A) ratio, which has been reported to be a simple but reliable prognostic indicator in our prior CAP study. This retrospective study included data from subjects who were hospitalized for CAP from August 2010 through October 2012 and who were administered the semi-quantitative serum procalcitonin test on admission. The demographic characteristics; laboratory biomarkers; microbiological test results; Pneumonia Severity Index scores; confusion, urea nitrogen, breathing frequency, blood pressure, ≥ 65 years of age (CURB-65) scale scores; and age, dehydration, respiratory failure, orientation disturbance, pressure (A-DROP) scale scores on hospital admission were retrieved from their medical charts. The outcomes were mortality within 28 days of hospital admission and the need for intensive care. Of the 213 subjects with CAP who were enrolled in the study, 20 died within 28 days of hospital admission, and 32 required intensive care. Mortality did not differ significantly among subjects with different semi-quantitative serum procalcitonin levels; however, subjects with serum procalcitonin levels ≥ 10.0 ng/mL were more likely to require intensive care than those with lower levels (P < .001). The elevation of semi-quantitative serum procalcitonin levels was more frequently observed in subjects with proven etiology, especially pneumococcal pneumonia. Using the receiver operating characteristic curves for mortality, the area under the curve was 0.86 for Pneumonia Severity Index class, 0.81 for B/A ratio, 0

  16. Accuracy in the estimation of quantitative minimal area from the diversity/area curve.

    PubMed

    Vives, Sergi; Salicrú, Miquel

    2005-05-01

    The problem of representativity is fundamental in ecological studies. A qualitative minimal area that gives a good representation of species pool [C.M. Bouderesque, Methodes d'etude qualitative et quantitative du benthos (en particulier du phytobenthos), Tethys 3(1) (1971) 79] can be discerned from a quantitative minimal area which reflects the structural complexity of community [F.X. Niell, Sobre la biologia de Ascophyllum nosodum (L.) Le Jolis en Galicia, Invest. Pesq. 43 (1979) 501]. This suggests that the populational diversity can be considered as the value of the horizontal asymptote corresponding to the curve sample diversity/biomass [F.X. Niell, Les applications de l'index de Shannon a l'etude de la vegetation interdidale, Soc. Phycol. Fr. Bull. 19 (1974) 238]. In this study we develop a expression to determine minimal areas and use it to obtain certain information about the community structure based on diversity/area curve graphs. This expression is based on the functional relationship between the expected value of the diversity and the sample size used to estimate it. In order to establish the quality of the estimation process, we obtained the confidence intervals as a particularization of the functional (h-phi)-entropies proposed in [M. Salicru, M.L. Menendez, D. Morales, L. Pardo, Asymptotic distribution of (h,phi)-entropies, Commun. Stat. (Theory Methods) 22 (7) (1993) 2015]. As an example used to demonstrate the possibilities of this method, and only for illustrative purposes, data about a study on the rocky intertidal seawed populations in the Ria of Vigo (N.W. Spain) are analyzed [F.X. Niell, Estudios sobre la estructura, dinamica y produccion del Fitobentos intermareal (Facies rocosa) de la Ria de Vigo. Ph.D. Mem. University of Barcelona, Barcelona, 1979].

  17. Effects of fecal sampling on preanalytical and analytical phases in quantitative fecal immunochemical tests for hemoglobin.

    PubMed

    Rapi, Stefano; Berardi, Margherita; Cellai, Filippo; Ciattini, Samuele; Chelazzi, Laura; Ognibene, Agostino; Rubeca, Tiziana

    2017-07-24

    Information on preanalytical variability is mandatory to bring laboratories up to ISO 15189 requirements. Fecal sampling is greatly affected by lack of harmonization in laboratory medicine. The aims of this study were to obtain information on the devices used for fecal sampling and to explore the effect of different amounts of feces on the results from the fecal immunochemical test for hemoglobin (FIT-Hb). Four commercial sample collection devices for quantitative FIT-Hb measurements were investigated. The volume of interest (VOI) of the probes was measured from diameter and geometry. Quantitative measurements of the mass of feces were carried out by gravimetry. The effects of an increased amount of feces on the analytical environment were investigated measuring the Hb values with a single analytical method. VOI was 8.22, 7.1 and 9.44 mm3 for probes that collected a target of 10 mg of feces, and 3.08 mm3 for one probe that targeted 2 mg of feces. The ratio between recovered and target amounts of devices ranged from 56% to 121%. Different changes in the measured Hb values were observed, in adding increasing amounts of feces in commercial buffers. The amounts of collected materials are related to the design of probes. Three out 4 manufacturers declare the same target amount using different sampling volumes and obtaining different amounts of collected materials. The introduction of a standard probes to reduce preanalytical variability could be an useful step for fecal test harmonization and to fulfill the ISO 15189 requirements.

  18. MR Fingerprinting for Rapid Quantitative Abdominal Imaging

    PubMed Central

    Chen, Yong; Jiang, Yun; Pahwa, Shivani; Ma, Dan; Lu, Lan; Twieg, Michael D.; Wright, Katherine L.; Seiberlich, Nicole; Griswold, Mark A.

    2016-01-01

    Purpose To develop a magnetic resonance (MR) “fingerprinting” technique for quantitative abdominal imaging. Materials and Methods This HIPAA-compliant study had institutional review board approval, and informed consent was obtained from all subjects. To achieve accurate quantification in the presence of marked B0 and B1 field inhomogeneities, the MR fingerprinting framework was extended by using a two-dimensional fast imaging with steady-state free precession, or FISP, acquisition and a Bloch-Siegert B1 mapping method. The accuracy of the proposed technique was validated by using agarose phantoms. Quantitative measurements were performed in eight asymptomatic subjects and in six patients with 20 focal liver lesions. A two-tailed Student t test was used to compare the T1 and T2 results in metastatic adenocarcinoma with those in surrounding liver parenchyma and healthy subjects. Results Phantom experiments showed good agreement with standard methods in T1 and T2 after B1 correction. In vivo studies demonstrated that quantitative T1, T2, and B1 maps can be acquired within a breath hold of approximately 19 seconds. T1 and T2 measurements were compatible with those in the literature. Representative values included the following: liver, 745 msec ± 65 (standard deviation) and 31 msec ± 6; renal medulla, 1702 msec ± 205 and 60 msec ± 21; renal cortex, 1314 msec ± 77 and 47 msec ± 10; spleen, 1232 msec ± 92 and 60 msec ± 19; skeletal muscle, 1100 msec ± 59 and 44 msec ± 9; and fat, 253 msec ± 42 and 77 msec ± 16, respectively. T1 and T2 in metastatic adenocarcinoma were 1673 msec ± 331 and 43 msec ± 13, respectively, significantly different from surrounding liver parenchyma relaxation times of 840 msec ± 113 and 28 msec ± 3 (P < .0001 and P < .01) and those in hepatic parenchyma in healthy volunteers (745 msec ± 65 and 31 msec ± 6, P < .0001 and P = .021, respectively). Conclusion A rapid technique for quantitative abdominal imaging was developed that

  19. MR Fingerprinting for Rapid Quantitative Abdominal Imaging.

    PubMed

    Chen, Yong; Jiang, Yun; Pahwa, Shivani; Ma, Dan; Lu, Lan; Twieg, Michael D; Wright, Katherine L; Seiberlich, Nicole; Griswold, Mark A; Gulani, Vikas

    2016-04-01

    To develop a magnetic resonance (MR) "fingerprinting" technique for quantitative abdominal imaging. This HIPAA-compliant study had institutional review board approval, and informed consent was obtained from all subjects. To achieve accurate quantification in the presence of marked B0 and B1 field inhomogeneities, the MR fingerprinting framework was extended by using a two-dimensional fast imaging with steady-state free precession, or FISP, acquisition and a Bloch-Siegert B1 mapping method. The accuracy of the proposed technique was validated by using agarose phantoms. Quantitative measurements were performed in eight asymptomatic subjects and in six patients with 20 focal liver lesions. A two-tailed Student t test was used to compare the T1 and T2 results in metastatic adenocarcinoma with those in surrounding liver parenchyma and healthy subjects. Phantom experiments showed good agreement with standard methods in T1 and T2 after B1 correction. In vivo studies demonstrated that quantitative T1, T2, and B1 maps can be acquired within a breath hold of approximately 19 seconds. T1 and T2 measurements were compatible with those in the literature. Representative values included the following: liver, 745 msec ± 65 (standard deviation) and 31 msec ± 6; renal medulla, 1702 msec ± 205 and 60 msec ± 21; renal cortex, 1314 msec ± 77 and 47 msec ± 10; spleen, 1232 msec ± 92 and 60 msec ± 19; skeletal muscle, 1100 msec ± 59 and 44 msec ± 9; and fat, 253 msec ± 42 and 77 msec ± 16, respectively. T1 and T2 in metastatic adenocarcinoma were 1673 msec ± 331 and 43 msec ± 13, respectively, significantly different from surrounding liver parenchyma relaxation times of 840 msec ± 113 and 28 msec ± 3 (P < .0001 and P < .01) and those in hepatic parenchyma in healthy volunteers (745 msec ± 65 and 31 msec ± 6, P < .0001 and P = .021, respectively). A rapid technique for quantitative abdominal imaging was developed that allows simultaneous quantification of multiple tissue

  20. Technique for quantitative RT-PCR analysis directly from single muscle fibers.

    PubMed

    Wacker, Michael J; Tehel, Michelle M; Gallagher, Philip M

    2008-07-01

    The use of single-cell quantitative RT-PCR has greatly aided the study of gene expression in fields such as muscle physiology. For this study, we hypothesized that single muscle fibers from a biopsy can be placed directly into the reverse transcription buffer and that gene expression data can be obtained without having to first extract the RNA. To test this hypothesis, biopsies were taken from the vastus lateralis of five male subjects. Single muscle fibers were isolated and underwent RNA isolation (technique 1) or placed directly into reverse transcription buffer (technique 2). After cDNA conversion, individual fiber cDNA was pooled and quantitative PCR was performed using primer-probes for beta(2)-microglobulin, glyceraldehyde-3-phosphate dehydrogenase, insulin-like growth factor I receptor, and glucose transporter subtype 4. The no RNA extraction method provided similar quantitative PCR data as that of the RNA extraction method. A third technique was also tested in which we used one-quarter of an individual fiber's cDNA for PCR (not pooled) and the average coefficient of variation between fibers was <8% (cycle threshold value) for all genes studied. The no RNA extraction technique was tested on isolated muscle fibers using a gene known to increase after exercise (pyruvate dehydrogenase kinase 4). We observed a 13.9-fold change in expression after resistance exercise, which is consistent with what has been previously observed. These results demonstrate a successful method for gene expression analysis directly from single muscle fibers.

  1. Intraocular pressure values obtained by ocular response analyzer, dynamic contour tonometry, and goldmann tonometry in keratokonic corneas.

    PubMed

    Bayer, Atilla; Sahin, Afsun; Hürmeriç, Volkan; Ozge, Gökhan

    2010-01-01

    To determine the agreement between dynamic contour tonometer (DCT), Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA) in keratoconic corneas and to find out the effect of corneal biomechanics on intraocular pressure (IOP) measurements obtained by these devices. IOP was measured with the ORA, DCT, and GAT in random order in 120 eyes of 61 keratoconus patients. Central corneal thickness (CCT) and keratometry were measured after all IOP determinations had been made. The mean IOP measurement by the ORA and DCT was compared with the measurement by the GAT, using Student t test. Bland-Altman analysis was performed to assess the clinical agreement between these methods. The effect of corneal hysteresis (CH), corneal resistance factor (CRF), and CCT on measured IOP was explored by multiple backward stepwise linear regression analysis. The mean±SD patient age was 30.6±11.2 years. The mean±SD IOP measurement obtained with GAT, ORA Goldmann-correlated IOP (IOPg), ORA corneal-compensated IOP (IOPcc), and DCT was 10.96±2.8, 10.23±3.5, 14.65±2.8, and 15.42±2.7 mm Hg, respectively. The mean±SD CCT was 464.08±58.4 microns. The mean difference between IOPcc and GAT (P<0.0001), IOPcc and DCT (P<0.001), GAT and DCT (P<0.0001), IOPg and GAT (P<0.002), and IOPg and DCT (P<0.0001), was highly statistically significant. In multivariable regression analysis, DCT IOP and GAT IOP measurements were significantly associated with CH and CRF (P<0.0001 for both). DCT seemed to be affected by CH and CRF, and the IOP values tended to be higher when compared with GAT. ORA-measured IOPcc was found to be independent of CCT and suitable in comparison to the DCT in keratoconic eyes.

  2. Evaluation and validation of the diagnostic value of the apparent diffusion coefficient for differentiating early-stage endometrial carcinomas from benign mimickers at 3T MRI.

    PubMed

    Wang, Xue; Zhao, Yu; Hu, Yumin; Zhou, Yongjin; Ye, Xinjian; Liu, Kun; Bai, Guanghui; Guo, Anna; Du, Meimei; Jiang, Lezhen; Wang, Jinhong; Yan, Zhihan

    2017-07-11

    Previous researchers obtained various apparent diffusion coefficient (ADC) cutoff values to differentiate endometrial carcinoma from benign mimickers with 1.5T magnetic resonance imaging (MRI). Few studies have used 3T MRI or validated the effectiveness of these cutoff ADC values prospectively. This study was designed in two stages to obtain a cutoff ADC value at 3T MRI and to validate prospectively the role of the ADC value. First, we conducted a retrospective study of 60 patients to evaluate the diagnostic value of ADC by obtain a theoretical cutoff ADC value for differentiating between benign and malignant endometrial lesions. Student's t test revealed that ADC values for stage I endometrial carcinomas were significantly lower than those for benign lesions. The area under the curve value of the receiver operating characteristic curve was 0.993, and the cutoff ADC value was 0.98 × 10-3 mm2/s. The sensitivity, specificity, and overall accuracy of diagnosing stage I endometrial carcinoma were 100%, 97.1%, and 98.3%, respectively. Second, we conducted a prospective study of 26 patients to validate the use of the cutoff ADC value obtained in the study's first stage. The sensitivity, specificity, and overall accuracy for differentiating malignant from benign endometrial lesions based on the cutoff ADC value obtained earlier were as follows: radiologist 1 attained 86.67%, 100.0%, and 92.31%, respectively; radiologist 2 attained 86.67%, 91.0%, and 88.5%, respectively. Our results suggest that ADC values could be a potential biomarker for use as a quantitative and qualitative tool for differentiating between early-stage endometrial carcinomas and benign mimickers.

  3. Evaluation and validation of the diagnostic value of the apparent diffusion coefficient for differentiating early-stage endometrial carcinomas from benign mimickers at 3T MRI

    PubMed Central

    Hu, Yumin; Zhou, Yongjin; Ye, Xinjian; Liu, Kun; Bai, Guanghui; Guo, Anna; Du, Meimei; Jiang, Lezhen

    2017-01-01

    Previous researchers obtained various apparent diffusion coefficient (ADC) cutoff values to differentiate endometrial carcinoma from benign mimickers with 1.5T magnetic resonance imaging (MRI). Few studies have used 3T MRI or validated the effectiveness of these cutoff ADC values prospectively. This study was designed in two stages to obtain a cutoff ADC value at 3T MRI and to validate prospectively the role of the ADC value. First, we conducted a retrospective study of 60 patients to evaluate the diagnostic value of ADC by obtain a theoretical cutoff ADC value for differentiating between benign and malignant endometrial lesions. Student's t test revealed that ADC values for stage I endometrial carcinomas were significantly lower than those for benign lesions. The area under the curve value of the receiver operating characteristic curve was 0.993, and the cutoff ADC value was 0.98 × 10−3 mm2/s. The sensitivity, specificity, and overall accuracy of diagnosing stage I endometrial carcinoma were 100%, 97.1%, and 98.3%, respectively. Second, we conducted a prospective study of 26 patients to validate the use of the cutoff ADC value obtained in the study's first stage. The sensitivity, specificity, and overall accuracy for differentiating malignant from benign endometrial lesions based on the cutoff ADC value obtained earlier were as follows: radiologist 1 attained 86.67%, 100.0%, and 92.31%, respectively; radiologist 2 attained 86.67%, 91.0%, and 88.5%, respectively. Our results suggest that ADC values could be a potential biomarker for use as a quantitative and qualitative tool for differentiating between early-stage endometrial carcinomas and benign mimickers. PMID:28634318

  4. Comparison of clinical semi-quantitative assessment of muscle fat infiltration with quantitative assessment using chemical shift-based water/fat separation in MR studies of the calf of post-menopausal women.

    PubMed

    Alizai, Hamza; Nardo, Lorenzo; Karampinos, Dimitrios C; Joseph, Gabby B; Yap, Samuel P; Baum, Thomas; Krug, Roland; Majumdar, Sharmila; Link, Thomas M

    2012-07-01

    The goal of this study was to compare the semi-quantitative Goutallier classification for fat infiltration with quantitative fat-fraction derived from a magnetic resonance imaging (MRI) chemical shift-based water/fat separation technique. Sixty-two women (age 61 ± 6 years), 27 of whom had diabetes, underwent MRI of the calf using a T1-weighted fast spin-echo sequence and a six-echo spoiled gradient-echo sequence at 3 T. Water/fat images and fat fraction maps were reconstructed using the IDEAL algorithm with T2* correction and a multi-peak model for the fat spectrum. Two radiologists scored fat infiltration on the T1-weighted images using the Goutallier classification in six muscle compartments. Spearman correlations between the Goutallier grades and the fat fraction were calculated; in addition, intra-observer and inter-observer agreement were calculated. A significant correlation between the clinical grading and the fat fraction values was found for all muscle compartments (P < 0.0001, R values ranging from 0.79 to 0.88). Goutallier grades 0-4 had a fat fraction ranging from 3.5 to 19%. Intra-observer and inter-observer agreement values of 0.83 and 0.81 were calculated for the semi-quantitative grading. Semi-quantitative grading of intramuscular fat and quantitative fat fraction were significantly correlated and both techniques had excellent reproducibility. However, the clinical grading was found to overestimate muscle fat. Fat infiltration of muscle commonly occurs in many metabolic and neuromuscular diseases. • Image-based semi-quantitative classifications for assessing fat infiltration are not well validated. • Quantitative MRI techniques provide an accurate assessment of muscle fat.

  5. Obtaining orthotropic elasticity tensor using entries zeroing method.

    NASA Astrophysics Data System (ADS)

    Gierlach, Bartosz; Danek, Tomasz

    2017-04-01

    A generally anisotropic elasticity tensor obtained from measurements can be represented by a tensor belonging to one of eight material symmetry classes. Knowledge of symmetry class and orientation is helpful for describing physical properties of a medium. For each non-trivial symmetry class except isotropic this problem is nonlinear. A common method of obtaining effective tensor is a choosing its non-trivial symmetry class and minimizing Frobenius norm between measured and effective tensor in the same coordinate system. Global optimization algorithm has to be used to determine the best rotation of a tensor. In this contribution, we propose a new approach to obtain optimal tensor, with the assumption that it is orthotropic (or at least has a similar shape to the orthotropic one). In orthotropic form tensor 24 out of 36 entries are zeros. The idea is to minimize the sum of squared entries which are supposed to be equal to zero through rotation calculated with optimization algorithm - in this case Particle Swarm Optimization (PSO) algorithm. Quaternions were used to parametrize rotations in 3D space to improve computational efficiency. In order to avoid a choice of local minima we apply PSO several times and only if we obtain similar results for the third time we consider it as a correct value and finish computations. To analyze obtained results Monte-Carlo method was used. After thousands of single runs of PSO optimization, we obtained values of quaternion parts and plot them. Points concentrate in several points of the graph following the regular pattern. It suggests the existence of more complex symmetry in the analyzed tensor. Then thousands of realizations of generally anisotropic tensor were generated - each tensor entry was replaced with a random value drawn from normal distribution having a mean equal to measured tensor entry and standard deviation of the measurement. Each of these tensors was subject of PSO based optimization delivering quaternion for optimal

  6. An Improved Method for Measuring Quantitative Resistance to the Wheat Pathogen Zymoseptoria tritici Using High-Throughput Automated Image Analysis.

    PubMed

    Stewart, Ethan L; Hagerty, Christina H; Mikaberidze, Alexey; Mundt, Christopher C; Zhong, Ziming; McDonald, Bruce A

    2016-07-01

    Zymoseptoria tritici causes Septoria tritici blotch (STB) on wheat. An improved method of quantifying STB symptoms was developed based on automated analysis of diseased leaf images made using a flatbed scanner. Naturally infected leaves (n = 949) sampled from fungicide-treated field plots comprising 39 wheat cultivars grown in Switzerland and 9 recombinant inbred lines (RIL) grown in Oregon were included in these analyses. Measures of quantitative resistance were percent leaf area covered by lesions, pycnidia size and gray value, and pycnidia density per leaf and lesion. These measures were obtained automatically with a batch-processing macro utilizing the image-processing software ImageJ. All phenotypes in both locations showed a continuous distribution, as expected for a quantitative trait. The trait distributions at both sites were largely overlapping even though the field and host environments were quite different. Cultivars and RILs could be assigned to two or more statistically different groups for each measured phenotype. Traditional visual assessments of field resistance were highly correlated with quantitative resistance measures based on image analysis for the Oregon RILs. These results show that automated image analysis provides a promising tool for assessing quantitative resistance to Z. tritici under field conditions.

  7. Assessing treatment response in triple-negative breast cancer from quantitative image analysis in perfusion magnetic resonance imaging.

    PubMed

    Banerjee, Imon; Malladi, Sadhika; Lee, Daniela; Depeursinge, Adrien; Telli, Melinda; Lipson, Jafi; Golden, Daniel; Rubin, Daniel L

    2018-01-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is sensitive but not specific to determining treatment response in early stage triple-negative breast cancer (TNBC) patients. We propose an efficient computerized technique for assessing treatment response, specifically the residual tumor (RT) status and pathological complete response (pCR), in response to neoadjuvant chemotherapy. The proposed approach is based on Riesz wavelet analysis of pharmacokinetic maps derived from noninvasive DCE-MRI scans, obtained before and after treatment. We compared the performance of Riesz features with the traditional gray level co-occurrence matrices and a comprehensive characterization of the lesion that includes a wide range of quantitative features (e.g., shape and boundary). We investigated a set of predictive models ([Formula: see text]) incorporating distinct combinations of quantitative characterizations and statistical models at different time points of the treatment and some area under the receiver operating characteristic curve (AUC) values we reported are above 0.8. The most efficient models are based on first-order statistics and Riesz wavelets, which predicted RT with an AUC value of 0.85 and pCR with an AUC value of 0.83, improving results reported in a previous study by [Formula: see text]. Our findings suggest that Riesz texture analysis of TNBC lesions can be considered a potential framework for optimizing TNBC patient care.

  8. An integrative strategy for quantitative analysis of the N-glycoproteome in complex biological samples.

    PubMed

    Wang, Ji; Zhou, Chuang; Zhang, Wei; Yao, Jun; Lu, Haojie; Dong, Qiongzhu; Zhou, Haijun; Qin, Lunxiu

    2014-01-15

    The complexity of protein glycosylation makes it difficult to characterize glycosylation patterns on a proteomic scale. In this study, we developed an integrated strategy for comparatively analyzing N-glycosylation/glycoproteins quantitatively from complex biological samples in a high-throughput manner. This strategy entailed separating and enriching glycopeptides/glycoproteins using lectin affinity chromatography, and then tandem labeling them with 18O/16O to generate a mass shift of 6 Da between the paired glycopeptides, and finally analyzing them with liquid chromatography-mass spectrometry (LC-MS) and the automatic quantitative method we developed based on Mascot Distiller. The accuracy and repeatability of this strategy were first verified using standard glycoproteins; linearity was maintained within a range of 1:10-10:1. The peptide concentration ratios obtained by the self-build quantitative method were similar to both the manually calculated and theoretical values, with a standard deviation (SD) of 0.023-0.186 for glycopeptides. The feasibility of the strategy was further confirmed with serum from hepatocellular carcinoma (HCC) patients and healthy individuals; the expression of 44 glycopeptides and 30 glycoproteins were significantly different between HCC patient and control serum. This strategy is accurate, repeatable, and efficient, and may be a useful tool for identification of disease-related N-glycosylation/glycoprotein changes.

  9. Investment appraisal using quantitative risk analysis.

    PubMed

    Johansson, Henrik

    2002-07-01

    Investment appraisal concerned with investments in fire safety systems is discussed. Particular attention is directed at evaluating, in terms of the Bayesian decision theory, the risk reduction that investment in a fire safety system involves. It is shown how the monetary value of the change from a building design without any specific fire protection system to one including such a system can be estimated by use of quantitative risk analysis, the results of which are expressed in terms of a Risk-adjusted net present value. This represents the intrinsic monetary value of investing in the fire safety system. The method suggested is exemplified by a case study performed in an Avesta Sheffield factory.

  10. Quantitative, spectrally-resolved intraoperative fluorescence imaging

    PubMed Central

    Valdés, Pablo A.; Leblond, Frederic; Jacobs, Valerie L.; Wilson, Brian C.; Paulsen, Keith D.; Roberts, David W.

    2012-01-01

    Intraoperative visual fluorescence imaging (vFI) has emerged as a promising aid to surgical guidance, but does not fully exploit the potential of the fluorescent agents that are currently available. Here, we introduce a quantitative fluorescence imaging (qFI) approach that converts spectrally-resolved data into images of absolute fluorophore concentration pixel-by-pixel across the surgical field of view (FOV). The resulting estimates are linear, accurate, and precise relative to true values, and spectral decomposition of multiple fluorophores is also achieved. Experiments with protoporphyrin IX in a glioma rodent model demonstrate in vivo quantitative and spectrally-resolved fluorescence imaging of infiltrating tumor margins for the first time. Moreover, we present images from human surgery which detect residual tumor not evident with state-of-the-art vFI. The wide-field qFI technique has broad implications for intraoperative surgical guidance because it provides near real-time quantitative assessment of multiple fluorescent biomarkers across the operative field. PMID:23152935

  11. Detection and semi-quantification of Strongylus vulgaris DNA in equine faeces by real-time quantitative PCR.

    PubMed

    Nielsen, Martin K; Peterson, David S; Monrad, Jesper; Thamsborg, Stig M; Olsen, Susanne N; Kaplan, Ray M

    2008-03-01

    Strongylus vulgaris is an important strongyle nematode with high pathogenic potential infecting horses world-wide. Several decades of intensive anthelmintic use has virtually eliminated clinical disease caused by S. vulgaris, but has also caused high levels of anthelmintic resistance in equine small strongyle (cyathostomin) nematodes. Recommendations aimed at limiting the development of anthelmintic resistance by reducing treatment intensity raises a simultaneous demand for reliable and accurate diagnostic tools for detecting important parasitic pathogens. Presently, the only means available to differentiate among strongyle species in a faecal sample is by identifying individual L3 larvae following a two week coproculture procedure. The aim of the present study is to overcome this diagnostic obstacle by developing a fluorescence-based quantitative PCR assay capable of identifying S. vulgaris eggs in faecal samples from horses. Species-specific primers and a TaqMan probe were designed by alignment of published ribosomal DNA sequences of the second internal transcribed spacer of cyathostomin and Strongylus spp. nematodes. The assay was tested for specificity and optimized using genomic DNA extracted from identified male worms of Strongylus and cyathostomin species. In addition, eggs were collected from adult female worms and used to evaluate the quantitative potential of the assay. Statistically significant linear relationships were found between egg numbers and cycle of threshold (Ct) values. PCR results were unaffected by the presence of cyathostomin DNA in the sample and there was no indication of PCR inhibition by faecal sources. A field evaluation on faecal samples obtained from four Danish horse farms revealed a good agreement with the traditional larval culture (kappa-value=0.78), but with a significantly higher performance of the PCR assay. An association between Ct values and S. vulgaris larval counts was statistically significant. The present assay can

  12. Post-event reviews: Using a quantitative approach for analysing incident response to demonstrate the value of business continuity programmes and increase planning efficiency.

    PubMed

    Vaidyanathan, Karthik

    2017-01-01

    Business continuity management is often thought of as a proactive planning process for minimising impact from large-scale incidents and disasters. While this is true, and it is critical to plan for the worst, consistently validating plan effectiveness against smaller disruptions can enable an organisation to gain key insights about its business continuity readiness, drive programme improvements, reduce costs and provide an opportunity to quantitatively demonstrate the value of the programme to management. This paper describes a post mortem framework which is used as a continuous improvement mechanism for tracking, reviewing and learning from real-world events at Microsoft Customer Service & Support. This approach was developed and adopted because conducting regular business continuity exercises proved difficult and expensive in a complex and distributed operations environment with high availability requirements. Using a quantitative approach to measure response to incidents, and categorising outcomes based on such responses, enables business continuity teams to provide data-driven insights to leadership, change perceptions of incident root cause, and instil a higher level of confidence towards disaster response readiness and incident management. The scope of the framework discussed here is specific to reviewing and driving improvements from operational incidents. However, the concept can be extended to learning and evolving readiness plans for other types of incidents.

  13. A simple approach to quantitative analysis using three-dimensional spectra based on selected Zernike moments.

    PubMed

    Zhai, Hong Lin; Zhai, Yue Yuan; Li, Pei Zhen; Tian, Yue Li

    2013-01-21

    A very simple approach to quantitative analysis is proposed based on the technology of digital image processing using three-dimensional (3D) spectra obtained by high-performance liquid chromatography coupled with a diode array detector (HPLC-DAD). As the region-based shape features of a grayscale image, Zernike moments with inherently invariance property were employed to establish the linear quantitative models. This approach was applied to the quantitative analysis of three compounds in mixed samples using 3D HPLC-DAD spectra, and three linear models were obtained, respectively. The correlation coefficients (R(2)) for training and test sets were more than 0.999, and the statistical parameters and strict validation supported the reliability of established models. The analytical results suggest that the Zernike moment selected by stepwise regression can be used in the quantitative analysis of target compounds. Our study provides a new idea for quantitative analysis using 3D spectra, which can be extended to the analysis of other 3D spectra obtained by different methods or instruments.

  14. Differences in liver stiffness values obtained with new ultrasound elastography machines and Fibroscan: A comparative study.

    PubMed

    Piscaglia, Fabio; Salvatore, Veronica; Mulazzani, Lorenzo; Cantisani, Vito; Colecchia, Antonio; Di Donato, Roberto; Felicani, Cristina; Ferrarini, Alessia; Gamal, Nesrine; Grasso, Valentina; Marasco, Giovanni; Mazzotta, Elena; Ravaioli, Federico; Ruggieri, Giacomo; Serio, Ilaria; Sitouok Nkamgho, Joules Fabrice; Serra, Carla; Festi, Davide; Schiavone, Cosima; Bolondi, Luigi

    2017-07-01

    Whether Fibroscan thresholds can be immediately adopted for none, some or all other shear wave elastography techniques has not been tested. The aim of the present study was to test the concordance of the findings obtained from 7 of the most recent ultrasound elastography machines with respect to Fibroscan. Sixteen hepatitis C virus-related patients with fibrosis ≥2 and having reliable results at Fibroscan were investigated in two intercostal spaces using 7 different elastography machines. Coefficients of both precision (an index of data dispersion) and accuracy (an index of bias correction factors expressing different magnitudes of changes in comparison to the reference) were calculated. Median stiffness values differed among the different machines as did coefficients of both precision (range 0.54-0.72) and accuracy (range 0.28-0.87). When the average of the measurements of two intercostal spaces was considered, coefficients of precision significantly increased with all machines (range 0.72-0.90) whereas of accuracy improved more scatteredly and by a smaller degree (range 0.40-0.99). The present results showed only moderate concordance of the majority of elastography machines with the Fibroscan results, preventing the possibility of the immediate universal adoption of Fibroscan thresholds for defining liver fibrosis staging for all new machines. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  15. Quantitative crystalline silica exposure assessment for a historical cohort epidemiologic study in the German porcelain industry.

    PubMed

    Birk, Thomas; Guldner, Karlheinz; Mundt, Kenneth A; Dahmann, Dirk; Adams, Robert C; Parsons, William

    2010-09-01

    A time-dependent quantitative exposure assessment of silica exposure among nearly 18,000 German porcelain workers was conducted. Results will be used to evaluate exposure-response disease risks. Over 8000 historical industrial hygiene (IH) measurements with original sampling and analysis protocols from 1954-2006 were obtained from the German Berufs- genossenschaft der keramischen-und Glas-Industrie (BGGK) and used to construct a job exposure matrix (JEM). Early measurements from different devices were converted to modern gravimetric equivalent values. Conversion factors were derived from parallel historical measurements and new side-by-side measurements using historical and modern devices in laboratory dust tunnels and active workplace locations. Exposure values were summarized and smoothed using LOESS regression; estimates for early years were derived using backward extrapolation techniques. Employee work histories were merged with JEM values to determine cumulative crystalline silica exposures for cohort members. Average silica concentrations were derived for six primary similar exposure groups (SEGs) for 1938-2006. Over 40% of the cohort accumulated <0.5 mg; just over one-third accumulated >1 mg/m(3)-years. Nearly 5000 workers had cumulative crystalline silica estimates >1.5 mg/m(3)-years. Similar numbers of men and women fell into each cumulative exposure category, except for 1113 women and 1567 men in the highest category. Over half of those hired before 1960 accumulated >3 mg/m(3)-years crystalline silica compared with 4.9% of those hired after 1960. Among those ever working in the materials preparation area, half accumulated >3 mg/m(3)-year compared with 12% of those never working in this area. Quantitative respirable silica exposures were estimated for each member of this cohort, including employment periods for which sampling used now obsolete technologies. Although individual cumulative exposure estimates ranged from background to about 40 mg/m(3)-years

  16. Quantitative MR imaging in fracture dating--Initial results.

    PubMed

    Baron, Katharina; Neumayer, Bernhard; Widek, Thomas; Schick, Fritz; Scheicher, Sylvia; Hassler, Eva; Scheurer, Eva

    2016-04-01

    For exact age determinations of bone fractures in a forensic context (e.g. in cases of child abuse) improved knowledge of the time course of the healing process and use of non-invasive modern imaging technology is of high importance. To date, fracture dating is based on radiographic methods by determining the callus status and thereby relying on an expert's experience. As a novel approach, this study aims to investigate the applicability of magnetic resonance imaging (MRI) for bone fracture dating by systematically investigating time-resolved changes in quantitative MR characteristics after a fracture event. Prior to investigating fracture healing in children, adults were examined for this study in order to test the methodology for this application. Altogether, 31 MR examinations in 17 subjects (♀: 11 ♂: 6; median age 34 ± 15 y, scanned 1-5 times over a period of up to 200 days after the fracture event) were performed on a clinical 3T MR scanner (TimTrio, Siemens AG, Germany). All subjects were treated conservatively for a fracture in either a long bone or in the collar bone. Both, qualitative and quantitative MR measurements were performed in all subjects. MR sequences for a quantitative measurement of relaxation times T1 and T2 in the fracture gap and musculature were applied. Maps of quantitative MR parameters T1, T2, and magnetisation transfer ratio (MTR) were calculated and evaluated by investigating changes over time in the fractured area by defined ROIs. Additionally, muscle areas were examined as reference regions to validate this approach. Quantitative evaluation of 23 MR data sets (12 test subjects, ♀: 7 ♂: 5) showed an initial peak in T1 values in the fractured area (T1=1895 ± 607 ms), which decreased over time to a value of 1094 ± 182 ms (200 days after the fracture event). T2 values also peaked for early-stage fractures (T2=115 ± 80 ms) and decreased to 73 ± 33 ms within 21 days after the fracture event. After that time point, no

  17. Augmenting Amyloid PET Interpretations With Quantitative Information Improves Consistency of Early Amyloid Detection.

    PubMed

    Harn, Nicholas R; Hunt, Suzanne L; Hill, Jacqueline; Vidoni, Eric; Perry, Mark; Burns, Jeffrey M

    2017-08-01

    Establishing reliable methods for interpreting elevated cerebral amyloid-β plaque on PET scans is increasingly important for radiologists, as availability of PET imaging in clinical practice increases. We examined a 3-step method to detect plaque in cognitively normal older adults, focusing on the additive value of quantitative information during the PET scan interpretation process. Fifty-five F-florbetapir PET scans were evaluated by 3 experienced raters. Scans were first visually interpreted as having "elevated" or "nonelevated" plaque burden ("Visual Read"). Images were then processed using a standardized quantitative analysis software (MIMneuro) to generate whole brain and region of interest SUV ratios. This "Quantitative Read" was considered elevated if at least 2 of 6 regions of interest had an SUV ratio of more than 1.1. The final interpretation combined both visual and quantitative data together ("VisQ Read"). Cohen kappa values were assessed as a measure of interpretation agreement. Plaque was elevated in 25.5% to 29.1% of the 165 total Visual Reads. Interrater agreement was strong (kappa = 0.73-0.82) and consistent with reported values. Quantitative Reads were elevated in 45.5% of participants. Final VisQ Reads changed from initial Visual Reads in 16 interpretations (9.7%), with most changing from "nonelevated" Visual Reads to "elevated." These changed interpretations demonstrated lower plaque quantification than those initially read as "elevated" that remained unchanged. Interrater variability improved for VisQ Reads with the addition of quantitative information (kappa = 0.88-0.96). Inclusion of quantitative information increases consistency of PET scan interpretations for early detection of cerebral amyloid-β plaque accumulation.

  18. Uncertainties in obtaining high reliability from stress-strength models

    NASA Technical Reports Server (NTRS)

    Neal, Donald M.; Matthews, William T.; Vangel, Mark G.

    1992-01-01

    There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.

  19. Teaching and Learning Moral Values through Kindergarten Curriculum

    ERIC Educational Resources Information Center

    Al-Hooli, Abeer; Al-Shammari, Zaid

    2009-01-01

    In this research study we investigated kindergarten-aged children's moral values in Kuwait. This study utilized several quantitative and qualitative research methods in the course of looking at three terms--moral development, the meaning of value, and the meaning of morality--as experienced by kindergarten-aged children. Participants were 600…

  20. Variability of dental cone beam CT grey values for density estimations

    PubMed Central

    Pauwels, R; Nackaerts, O; Bellaiche, N; Stamatakis, H; Tsiklakis, K; Walker, A; Bosmans, H; Bogaerts, R; Jacobs, R; Horner, K

    2013-01-01

    Objective The aim of this study was to investigate the use of dental cone beam CT (CBCT) grey values for density estimations by calculating the correlation with multislice CT (MSCT) values and the grey value error after recalibration. Methods A polymethyl methacrylate (PMMA) phantom was developed containing inserts of different density: air, PMMA, hydroxyapatite (HA) 50 mg cm−3, HA 100, HA 200 and aluminium. The phantom was scanned on 13 CBCT devices and 1 MSCT device. Correlation between CBCT grey values and CT numbers was calculated, and the average error of the CBCT values was estimated in the medium-density range after recalibration. Results Pearson correlation coefficients ranged between 0.7014 and 0.9996 in the full-density range and between 0.5620 and 0.9991 in the medium-density range. The average error of CBCT voxel values in the medium-density range was between 35 and 1562. Conclusion Even though most CBCT devices showed a good overall correlation with CT numbers, large errors can be seen when using the grey values in a quantitative way. Although it could be possible to obtain pseudo-Hounsfield units from certain CBCTs, alternative methods of assessing bone tissue should be further investigated. Advances in knowledge The suitability of dental CBCT for density estimations was assessed, involving a large number of devices and protocols. The possibility for grey value calibration was thoroughly investigated. PMID:23255537

  1. Value-Added to What? How a Ceiling in the Testing Instrument Influences Value-Added Estimation. NBER Working Paper No. 14778

    ERIC Educational Resources Information Center

    Koedel, Cory; Betts, Julian

    2009-01-01

    Value-added measures of teacher quality may be sensitive to the quantitative properties of the student tests upon which they are based. This paper focuses on the sensitivity of value- added to test-score-ceiling effects. Test-score ceilings are increasingly common in testing instruments across the country as education policy continues to emphasize…

  2. Accuracy Evaluation of the Unified P-Value from Combining Correlated P-Values

    PubMed Central

    Alves, Gelio; Yu, Yi-Kuo

    2014-01-01

    Meta-analysis methods that combine -values into a single unified -value are frequently employed to improve confidence in hypothesis testing. An assumption made by most meta-analysis methods is that the -values to be combined are independent, which may not always be true. To investigate the accuracy of the unified -value from combining correlated -values, we have evaluated a family of statistical methods that combine: independent, weighted independent, correlated, and weighted correlated -values. Statistical accuracy evaluation by combining simulated correlated -values showed that correlation among -values can have a significant effect on the accuracy of the combined -value obtained. Among the statistical methods evaluated those that weight -values compute more accurate combined -values than those that do not. Also, statistical methods that utilize the correlation information have the best performance, producing significantly more accurate combined -values. In our study we have demonstrated that statistical methods that combine -values based on the assumption of independence can produce inaccurate -values when combining correlated -values, even when the -values are only weakly correlated. Therefore, to prevent from drawing false conclusions during hypothesis testing, our study advises caution be used when interpreting the -value obtained from combining -values of unknown correlation. However, when the correlation information is available, the weighting-capable statistical method, first introduced by Brown and recently modified by Hou, seems to perform the best amongst the methods investigated. PMID:24663491

  3. pH Mapping on Tooth Surfaces for Quantitative Caries Diagnosis Using Micro Ir/IrOx pH Sensor.

    PubMed

    Ratanaporncharoen, Chindanai; Tabata, Miyuki; Kitasako, Yuichi; Ikeda, Masaomi; Goda, Tatsuro; Matsumoto, Akira; Tagami, Junji; Miyahara, Yuji

    2018-04-03

    A quantitative diagnostic method for dental caries would improve oral health, which directly affects the quality of life. Here we describe the preparation and application of Ir/IrOx pH sensors, which are used to measure the surface pH of dental caries. The pH level is used as an indicator to distinguish between active and arrested caries. After a dentist visually inspected and defined 18 extracted dentinal caries at various positions as active or arrested caries, the surface pH values of sound and caries areas were directly measured with an Ir/IrOx pH sensor with a diameter of 300 μm as a dental explorer. The average pH values of the sound root, the arrested caries, and active caries were 6.85, 6.07, and 5.30, respectively. The pH obtained with an Ir/IrOx sensor was highly correlated with the inspection results by the dentist, indicating that the types of caries were successfully categorized. This caries testing technique using a micro Ir/IrOx pH sensor provides an accurate quantitative caries evaluation and has potential in clinical diagnosis.

  4. Quantitative phase imaging of arthropods

    PubMed Central

    Sridharan, Shamira; Katz, Aron; Soto-Adames, Felipe; Popescu, Gabriel

    2015-01-01

    Abstract. Classification of arthropods is performed by characterization of fine features such as setae and cuticles. An unstained whole arthropod specimen mounted on a slide can be preserved for many decades, but is difficult to study since current methods require sample manipulation or tedious image processing. Spatial light interference microscopy (SLIM) is a quantitative phase imaging (QPI) technique that is an add-on module to a commercial phase contrast microscope. We use SLIM to image a whole organism springtail Ceratophysella denticulata mounted on a slide. This is the first time, to our knowledge, that an entire organism has been imaged using QPI. We also demonstrate the ability of SLIM to image fine structures in addition to providing quantitative data that cannot be obtained by traditional bright field microscopy. PMID:26334858

  5. The impact of white matter fiber orientation in single-acquisition quantitative susceptibility mapping.

    PubMed

    Lancione, Marta; Tosetti, Michela; Donatelli, Graziella; Cosottini, Mirco; Costagli, Mauro

    2017-11-01

    The aim of this work was to assess the impact of tissue structural orientation on quantitative susceptibility mapping (QSM) reliability, and to provide a criterion to identify voxels in which measures of magnetic susceptibility (χ) are most affected by spatial orientation effects. Four healthy volunteers underwent 7-T magnetic resonance imaging (MRI). Multi-echo, gradient-echo sequences were used to obtain quantitative maps of frequency shift (FS) and χ. Information from diffusion tensor imaging (DTI) was used to investigate the relationship between tissue orientation and FS measures and QSM. After sorting voxels on the basis of their fractional anisotropy (FA), the variations in FS and χ values over tissue orientation were measured. Using a K-means clustering algorithm, voxels were separated into two groups depending on the variability of measures within each FA interval. The consistency of FS and QSM values, observed at low FA, was disrupted for FA > 0.6. The standard deviation of χ measured at high FA (0.0103 ppm) was nearly five times that at low FA (0.0022 ppm). This result was consistent through data across different head positions and for different brain regions considered separately, which confirmed that such behavior does not depend on structures with different bulk susceptibility oriented along particular angles. The reliability of single-orientation QSM anticorrelates with local FA. QSM provides replicable values with little variability in brain regions with FA < 0.6, but QSM should be interpreted cautiously in major and coherent fiber bundles, which are strongly affected by structural anisotropy and magnetic susceptibility anisotropy. Copyright © 2017 John Wiley & Sons, Ltd.

  6. New method for obtaining position and time structure of source in HDR remote afterloading brachytherapy unit utilizing light emission from scintillator

    PubMed Central

    Hanada, Takashi; Katsuta, Shoichi; Yorozu, Atsunori; Maruyama, Koichi

    2009-01-01

    When using a HDR remote afterloading brachytherapy unit, results of treatment can be greatly influenced by both source position and treatment time. The purpose of this study is to obtain information on the source of the HDR remote afterloading unit, such as its position and time structure, with the use of a simple system consisting of a plastic scintillator block and a charge‐coupled device (CCD) camera. The CCD camera was used for recording images of scintillation luminescence at a fixed rate of 30 frames per second in real time. The source position and time structure were obtained by analyzing the recorded images. For a preset source‐step‐interval of 5 mm, the measured value of the source position was 5.0±1.0mm, with a pixel resolution of 0.07 mm in the recorded images. For a preset transit time of 30 s, the measured value was 30.0±0.6 s, when the time resolution of the CCD camera was 1/30 s. This system enabled us to obtain the source dwell time and movement time. Therefore, parameters such as I192r source position, transit time, dwell time, and movement time at each dwell position can be determined quantitatively using this plastic scintillator‐CCD camera system. PACS number: 87.53.Jw

  7. Espousing Democratic Leadership Practices: A Study of Values in Action

    ERIC Educational Resources Information Center

    Devereaux, Lorraine

    2003-01-01

    This article examines principals' espoused values and their values in action. It provides a reanalysis of previously collected data through a values lens. The original research study was an international quantitative and qualitative investigation of principals' leadership approaches that was based in 15 schools. This particular excerpt of the…

  8. Comparison of quantitative and qualitative tests for glucose-6-phosphate dehydrogenase deficiency in the neonatal period.

    PubMed

    Keihanian, F; Basirjafari, S; Darbandi, B; Saeidinia, A; Jafroodi, M; Sharafi, R; Shakiba, M

    2017-06-01

    Considering the high prevalence of glucose-6-phosphate dehydrogenase (G6PD) deficiency among newborns, different screening methods have been established in various countries. In this study, we aimed to assess the prevalence of G6PD deficiency among newborns in Rasht, Iran, and compare G6PD activity in cord blood samples, using quantitative and qualitative tests. This cross-sectional, prospective study was performed at five largest hospitals in Rasht, Guilan Province, Iran. The screening tests were performed for all the newborns, referred to these hospitals. Specimens were characterized in terms of G6PD activity under ultraviolet light, using the kinetic method and the qualitative fluorescent spot test (FST). We also determined the sensitivity, specificity, negative predictive value, and positive predictive value of the qualitative assay. Blood samples were collected from 1474 newborns. Overall, 757 (51.4%) subjects were male. As the findings revealed, 1376 (93.4%) newborns showed normal G6PD activity, while 98 (6.6%) had G6PD deficiency. There was a significant difference in the mean G6PD level between males and females (P = 0.0001). Also, a significant relationship was detected between FST results and the mean values obtained in the quantitative test (P < 0.0001). According to the present study, FST showed acceptable sensitivity and specificity for G6PD activity, although it appeared inefficient for diagnostic purposes in some cases. © 2017 John Wiley & Sons Ltd.

  9. An Illustration of Determining Quantitatively the Rock Mass Quality Parameters of the Hoek-Brown Failure Criterion

    NASA Astrophysics Data System (ADS)

    Wu, Li; Adoko, Amoussou Coffi; Li, Bo

    2018-04-01

    In tunneling, determining quantitatively the rock mass strength parameters of the Hoek-Brown (HB) failure criterion is useful since it can improve the reliability of the design of tunnel support systems. In this study, a quantitative method is proposed to determine the rock mass quality parameters of the HB failure criterion, namely the Geological Strength Index (GSI) and the disturbance factor ( D) based on the structure of drilling core and weathering condition of rock mass combined with acoustic wave test to calculate the strength of rock mass. The Rock Mass Structure Index and the Rock Mass Weathering Index are used to quantify the GSI while the longitudinal wave velocity ( V p) is employed to derive the value of D. The DK383+338 tunnel face of Yaojia tunnel of Shanghai-Kunming passenger dedicated line served as illustration of how the methodology is implemented. The values of the GSI and D are obtained using the HB criterion and then using the proposed method. The measured in situ stress is used to evaluate their accuracy. To this end, the major and minor principal stresses are calculated based on the GSI and D given by HB criterion and the proposed method. The results indicated that both methods were close to the field observation which suggests that the proposed method can be used for determining quantitatively the rock quality parameters, as well. However, these results remain valid only for rock mass quality and rock type similar to those of the DK383+338 tunnel face of Yaojia tunnel.

  10. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume.

    PubMed

    Heijtel, D F R; Petersen, E T; Mutsaerts, H J M M; Bakker, E; Schober, P; Stevens, M F; van Berckel, B N M; Majoie, C B L M; Booij, J; van Osch, M J P; van Bavel, E T; Boellaard, R; Lammertsma, A A; Nederveen, A J

    2016-04-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P < 0.05), although QUASAR significantly underestimated CBF by 30% (P < 0.001). CBVA was moderately correlated (r(2): 0.28-0.43, P < 0.05), with QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P < 0.001). Group-wise voxel statistics identified minor areas with significant contrast differences between [(15)O]H2O PET and QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Comparison of cerebral vascular reactivity measures obtained using breath-holding and CO2 inhalation

    PubMed Central

    Tancredi, Felipe B; Hoge, Richard D

    2013-01-01

    Stimulation of cerebral vasculature using hypercapnia has been widely used to study cerebral vascular reactivity (CVR), which can be expressed as the quantitative change in cerebral blood flow (CBF) per mm Hg change in end-tidal partial pressure of CO2 (PETCO2). We investigate whether different respiratory manipulations, with arterial spin labeling used to measure CBF, lead to consistent measures of CVR. The approaches included: (1) an automated system delivering variable concentrations of inspired CO2 for prospective targeting of PETCO2, (2) administration of a fixed concentration of CO2 leading to subject-dependent changes in PETCO2, (3) a breath-hold (BH) paradigm with physiologic modeling of CO2 accumulation, and (4) a maneuver combining breath-hold and hyperventilation. When CVR was expressed as the percent change in CBF per mm Hg change in PETCO2, methods 1 to 3 gave consistent results. The CVR values using method 4 were significantly lower. When CVR was expressed in terms of the absolute change in CBF (mL/100 g per minute per mm Hg), greater discrepancies became apparent: methods 2 and 3 gave lower absolute CVR values compared with method 1, and the value obtained with method 4 was dramatically lower. Our findings indicate that care must be taken to ensure that CVR is measured over the linear range of the CBF-CO2 dose–response curve, avoiding hypocapnic conditions. PMID:23571282

  12. On Measuring Quantitative Interpretations of Reasonable Doubt

    ERIC Educational Resources Information Center

    Dhami, Mandeep K.

    2008-01-01

    Beyond reasonable doubt represents a probability value that acts as the criterion for conviction in criminal trials. I introduce the membership function (MF) method as a new tool for measuring quantitative interpretations of reasonable doubt. Experiment 1 demonstrated that three different methods (i.e., direct rating, decision theory based, and…

  13. Quantitative evaluation methods of skin condition based on texture feature parameters.

    PubMed

    Pang, Hui; Chen, Tianhua; Wang, Xiaoyi; Chang, Zhineng; Shao, Siqi; Zhao, Jing

    2017-03-01

    In order to quantitatively evaluate the improvement of the skin condition after using skin care products and beauty, a quantitative evaluation method for skin surface state and texture is presented, which is convenient, fast and non-destructive. Human skin images were collected by image sensors. Firstly, the median filter of the 3 × 3 window is used and then the location of the hairy pixels on the skin is accurately detected according to the gray mean value and color information. The bilinear interpolation is used to modify the gray value of the hairy pixels in order to eliminate the negative effect of noise and tiny hairs on the texture. After the above pretreatment, the gray level co-occurrence matrix (GLCM) is calculated. On the basis of this, the four characteristic parameters, including the second moment, contrast, entropy and correlation, and their mean value are calculated at 45 ° intervals. The quantitative evaluation model of skin texture based on GLCM is established, which can calculate the comprehensive parameters of skin condition. Experiments show that using this method evaluates the skin condition, both based on biochemical indicators of skin evaluation methods in line, but also fully consistent with the human visual experience. This method overcomes the shortcomings of the biochemical evaluation method of skin damage and long waiting time, also the subjectivity and fuzziness of the visual evaluation, which achieves the non-destructive, rapid and quantitative evaluation of skin condition. It can be used for health assessment or classification of the skin condition, also can quantitatively evaluate the subtle improvement of skin condition after using skin care products or stage beauty.

  14. [Gas Concentration Measurement Based on the Integral Value of Absorptance Spectrum].

    PubMed

    Liu, Hui-jun; Tao, Shao-hua; Yang, Bing-chu; Deng, Hong-gui

    2015-12-01

    The absorptance spectrum of a gas is the basis for the qualitative and quantitative analysis of the gas by the law of the Lambert-Beer. The integral value of the absorptance spectrum is an important parameter to describe the characteristics of the gas absorption. Based on the measured absorptance spectrum of a gas, we collected the required data from the database of HIT-RAN, and chose one of the spectral lines and calculated the integral value of the absorptance spectrum in the frequency domain, and then substituted the integral value into Lambert-Beer's law to obtain the concentration of the detected gas. By calculating the integral value of the absorptance spectrum we can avoid the more complicated calculation of the spectral line function and a series of standard gases for calibration, so the gas concentration measurement will be simpler and faster. We studied the changing trends of the integral values of the absorptance spectrums versus temperature. Since temperature variation would cause the corresponding variation in pressure, we studied the changing trends of the integral values of the absorptance spectrums versus both the pressure not changed with temperature and changed with the temperature variation. Based on the two cases, we found that the integral values of the absorptance spectrums both would firstly increase, then decrease, and finally stabilize with temperature increasing, but the ranges of specific changing trend were different in the two cases. In the experiments, we found that the relative errors of the integrated values of the absorptance spectrum were much higher than 1% and still increased with temperature when we only considered the change of temperature and completely ignored the pressure affected by the temperature variation, and the relative errors of the integrated values of the absorptance spectrum were almost constant at about only 1% when we considered that the pressure were affected by the temperature variation. As the integral value

  15. Diagnostic accuracy of quantitative real-time PCR assay versus clinical and Gram stain identification of bacterial vaginosis.

    PubMed

    Menard, J-P; Mazouni, C; Fenollar, F; Raoult, D; Boubli, L; Bretelle, F

    2010-12-01

    The purpose of this investigation was to determine the diagnostic accuracy of quantitative real-time polymerase chain reaction (PCR) assay in diagnosing bacterial vaginosis versus the standard methods, the Amsel criteria and the Nugent score. The Amsel criteria, the Nugent score, and results from the molecular tool were obtained independently from vaginal samples of 163 pregnant women who reported abnormal vaginal symptoms before 20 weeks gestation. To determine the performance of the molecular tool, we calculated the kappa value, sensitivity, specificity, and positive and negative predictive values. Either or both of the Amsel criteria (≥3 criteria) and the Nugent score (score ≥7) indicated that 25 women (15%) had bacterial vaginosis, and the remaining 138 women did not. DNA levels of Gardnerella vaginalis or Atopobium vaginae exceeded 10(9) copies/mL or 10(8) copies/mL, respectively, in 34 (21%) of the 163 samples. Complete agreement between both reference methods and high concentrations of G. vaginalis and A. vaginae was found in 94.5% of women (154/163 samples, kappa value = 0.81, 95% confidence interval 0.70-0.81). The nine samples with discordant results were categorized as intermediate flora by the Nugent score. The molecular tool predicted bacterial vaginosis with a sensitivity of 100%, a specificity of 93%, a positive predictive value of 73%, and a negative predictive value of 100%. The quantitative real-time PCR assay shows excellent agreement with the results of both reference methods for the diagnosis of bacterial vaginosis.

  16. Quantitative ptychographic reconstruction by applying a probe constraint

    NASA Astrophysics Data System (ADS)

    Reinhardt, J.; Schroer, C. G.

    2018-04-01

    The coherent scanning technique X-ray ptychography has become a routine tool for high-resolution imaging and nanoanalysis in various fields of research such as chemistry, biology or materials science. Often the ptychographic reconstruction results are analysed in order to yield absolute quantitative values for the object transmission and illuminating probe function. In this work, we address a common ambiguity encountered in scaling the object transmission and probe intensity via the application of an additional constraint to the reconstruction algorithm. A ptychographic measurement of a model sample containing nanoparticles is used as a test data set against which to benchmark in the reconstruction results depending on the type of constraint used. Achieving quantitative absolute values for the reconstructed object transmission is essential for advanced investigation of samples that are changing over time, e.g., during in-situ experiments or in general when different data sets are compared.

  17. Investigation of the influence of sampling schemes on quantitative dynamic fluorescence imaging

    PubMed Central

    Dai, Yunpeng; Chen, Xueli; Yin, Jipeng; Wang, Guodong; Wang, Bo; Zhan, Yonghua; Nie, Yongzhan; Wu, Kaichun; Liang, Jimin

    2018-01-01

    Dynamic optical data from a series of sampling intervals can be used for quantitative analysis to obtain meaningful kinetic parameters of probe in vivo. The sampling schemes may affect the quantification results of dynamic fluorescence imaging. Here, we investigate the influence of different sampling schemes on the quantification of binding potential (BP) with theoretically simulated and experimentally measured data. Three groups of sampling schemes are investigated including the sampling starting point, sampling sparsity, and sampling uniformity. In the investigation of the influence of the sampling starting point, we further summarize two cases by considering the missing timing sequence between the probe injection and sampling starting time. Results show that the mean value of BP exhibits an obvious growth trend with an increase in the delay of the sampling starting point, and has a strong correlation with the sampling sparsity. The growth trend is much more obvious if throwing the missing timing sequence. The standard deviation of BP is inversely related to the sampling sparsity, and independent of the sampling uniformity and the delay of sampling starting time. Moreover, the mean value of BP obtained by uniform sampling is significantly higher than that by using the non-uniform sampling. Our results collectively suggest that a suitable sampling scheme can help compartmental modeling of dynamic fluorescence imaging provide more accurate results and simpler operations. PMID:29675325

  18. Quantitative 3D investigation of Neuronal network in mouse spinal cord model

    NASA Astrophysics Data System (ADS)

    Bukreeva, I.; Campi, G.; Fratini, M.; Spanò, R.; Bucci, D.; Battaglia, G.; Giove, F.; Bravin, A.; Uccelli, A.; Venturi, C.; Mastrogiacomo, M.; Cedola, A.

    2017-01-01

    The investigation of the neuronal network in mouse spinal cord models represents the basis for the research on neurodegenerative diseases. In this framework, the quantitative analysis of the single elements in different districts is a crucial task. However, conventional 3D imaging techniques do not have enough spatial resolution and contrast to allow for a quantitative investigation of the neuronal network. Exploiting the high coherence and the high flux of synchrotron sources, X-ray Phase-Contrast multiscale-Tomography allows for the 3D investigation of the neuronal microanatomy without any aggressive sample preparation or sectioning. We investigated healthy-mouse neuronal architecture by imaging the 3D distribution of the neuronal-network with a spatial resolution of 640 nm. The high quality of the obtained images enables a quantitative study of the neuronal structure on a subject-by-subject basis. We developed and applied a spatial statistical analysis on the motor neurons to obtain quantitative information on their 3D arrangement in the healthy-mice spinal cord. Then, we compared the obtained results with a mouse model of multiple sclerosis. Our approach paves the way to the creation of a “database” for the characterization of the neuronal network main features for a comparative investigation of neurodegenerative diseases and therapies.

  19. Comparison of clinical semi-quantitative assessment of muscle fat infiltration with quantitative assessment using chemical shift-based water/fat separation in MR studies of the calf of post-menopausal women

    PubMed Central

    Nardo, Lorenzo; Karampinos, Dimitrios C.; Joseph, Gabby B.; Yap, Samuel P.; Baum, Thomas; Krug, Roland; Majumdar, Sharmila; Link, Thomas M.

    2013-01-01

    Objective The goal of this study was to compare the semi-quantitative Goutallier classification for fat infiltration with quantitative fat-fraction derived from a magnetic resonance imaging (MRI) chemical shift-based water/fat separation technique. Methods Sixty-two women (age 61±6 years), 27 of whom had diabetes, underwent MRI of the calf using a T1-weighted fast spin-echo sequence and a six-echo spoiled gradient-echo sequence at 3 T. Water/fat images and fat fraction maps were reconstructed using the IDEAL algorithm with T2* correction and a multi-peak model for the fat spectrum. Two radiologists scored fat infiltration on the T1-weighted images using the Goutallier classification in six muscle compartments. Spearman correlations between the Goutallier grades and the fat fraction were calculated; in addition, intra-observer and inter-observer agreement were calculated. Results A significant correlation between the clinical grading and the fat fraction values was found for all muscle compartments (P<0.0001, R values ranging from 0.79 to 0.88). Goutallier grades 0–4 had a fat fraction ranging from 3.5 to 19%. Intra-observer and inter-observer agreement values of 0.83 and 0.81 were calculated for the semi-quantitative grading. Conclusion Semi-quantitative grading of intramuscular fat and quantitative fat fraction were significantly correlated and both techniques had excellent reproducibility. However, the clinical grading was found to overestimate muscle fat. PMID:22411305

  20. Method of quantitating dsDNA

    DOEpatents

    Stark, Peter C.; Kuske, Cheryl R.; Mullen, Kenneth I.

    2002-01-01

    A method for quantitating dsDNA in an aqueous sample solution containing an unknown amount of dsDNA. A first aqueous test solution containing a known amount of a fluorescent dye-dsDNA complex and at least one fluorescence-attenutating contaminant is prepared. The fluorescence intensity of the test solution is measured. The first test solution is diluted by a known amount to provide a second test solution having a known concentration of dsDNA. The fluorescence intensity of the second test solution is measured. Additional diluted test solutions are similarly prepared until a sufficiently dilute test solution having a known amount of dsDNA is prepared that has a fluorescence intensity that is not attenuated upon further dilution. The value of the maximum absorbance of this solution between 200-900 nanometers (nm), referred to herein as the threshold absorbance, is measured. A sample solution having an unknown amount of dsDNA and an absorbance identical to that of the sufficiently dilute test solution at the same chosen wavelength is prepared. Dye is then added to the sample solution to form the fluorescent dye-dsDNA-complex, after which the fluorescence intensity of the sample solution is measured and the quantity of dsDNA in the sample solution is determined. Once the threshold absorbance of a sample solution obtained from a particular environment has been determined, any similarly prepared sample solution taken from a similar environment and having the same value for the threshold absorbance can be quantified for dsDNA by adding a large excess of dye to the sample solution and measuring its fluorescence intensity.

  1. International Standards and Reference Materials for Quantitative Molecular Infectious Disease Testing

    PubMed Central

    Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.

    2010-01-01

    The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208

  2. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    PubMed

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    analysis our results show similar diagnostic accuracy comparing anatomical (AUC 0.86(0.83-0.89)) and functional reference standards (AUC 0.88(0.84-0.90)). Only the per territory analysis sensitivity did not show significant heterogeneity. None of the groups showed signs of publication bias. The clinical value of semi-quantitative and quantitative CMR perfusion analysis remains uncertain due to extensive inter-study heterogeneity and large differences in CMR perfusion acquisition protocols, reference standards, and methods of assessment of myocardial perfusion parameters. For wide spread implementation, standardization of CMR perfusion techniques is essential. CRD42016040176 .

  3. Quantitative trait locus for reading disability on chromosome 6

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardon, L.R.; Smith, S.D.; Kimberling, W.J.

    1994-10-14

    Interval mapping of data from two independent samples of sib pairs, at least one member of whom was reading disabled, revealed evidence for a quantitative trait locus (QTL) on chromosome 6. Results obtained from analyses of reading performance from 114 sib pairs genotyped for DNA markers localized the QTL to 6p21.3. Analyses of corresponding data from an independent sample of 50 dizygotic twin pairs provided evidence for linkage to the same region. In combination, the replicate samples yielded a x{sup 2} value of 16.73 (P = 0.0002). Examination of twin and kindred siblings with more extreme deficits in reading performancemore » yielded even stronger evidence for a QTL (x{sup 2} = 27.35, P < 0.00001). The position of the QTL was narrowly defined with a 100:1 confidence interval to a 2-centimorgan region within the human leukocyte antigen complex. 23 refs., 4 figs.« less

  4. Quantitative computed tomography assessment of transfusional iron overload.

    PubMed

    Wood, John C; Mo, Ashley; Gera, Aakansha; Koh, Montre; Coates, Thomas; Gilsanz, Vicente

    2011-06-01

    Quantitative computed tomography (QCT) has been proposed for iron quantification for more than 30 years, however there has been little clinical validation. We compared liver attenuation by QCT with magnetic resonance imaging (MRI)-derived estimates of liver iron concentration (LIC) in 37 patients with transfusional siderosis. MRI and QCT measurements were performed as clinically indicated monitoring of LIC and vertebral bone-density respectively, over a 6-year period. Mean time difference between QCT and MRI studies was 14 d, with 25 studies performed on the same day. For liver attenuation outside the normal range, attenuation values rose linearly with LIC (r(2) = 0·94). However, intersubject variability in intrinsic liver attenuation prevented quantitation of LIC <8 mg/g dry weight of liver, and was the dominant source of measurement uncertainty. Calculated QCT and MRI accuracies were equivalent for LIC values approaching 22 mg/g dry weight, with QCT having superior performance at higher LIC's. Although not suitable for monitoring patients with good iron control, QCT may nonetheless represent a viable technique for liver iron quantitation in patients with moderate to severe iron in regions where MRI resources are limited because of its low cost, availability, and high throughput. © 2011 Blackwell Publishing Ltd.

  5. Quantitative Real-Time Legionella PCR for Environmental Water Samples: Data Interpretation

    PubMed Central

    Joly, Philippe; Falconnet, Pierre-Alain; André, Janine; Weill, Nicole; Reyrolle, Monique; Vandenesch, François; Maurin, Max; Etienne, Jerome; Jarraud, Sophie

    2006-01-01

    Quantitative Legionella PCRs targeting the 16S rRNA gene (specific for the genus Legionella) and the mip gene (specific for the species Legionella pneumophila) were applied to a total of 223 hot water system samples (131 in one laboratory and 92 in another laboratory) and 37 cooling tower samples (all in the same laboratory). The PCR results were compared with those of conventional culture. 16S rRNA gene PCR results were nonquantifiable for 2.8% of cooling tower samples and up to 39.1% of hot water system samples, and this was highly predictive of Legionella CFU counts below 250/liter. PCR cutoff values for identifying hot water system samples containing >103 CFU/liter legionellae were determined separately in each laboratory. The cutoffs differed widely between the laboratories and had sensitivities from 87.7 to 92.9% and specificities from 77.3 to 96.5%. The best specificity was obtained with mip PCR. PCR cutoffs could not be determined for cooling tower samples, as the results were highly variable and often high for culture-negative samples. Thus, quantitative Legionella PCR appears to be applicable to samples from hot water systems, but the positivity cutoff has to be determined in each laboratory. PMID:16597985

  6. Quantitative diagnostic method for biceps long head tendinitis by using ultrasound.

    PubMed

    Huang, Shih-Wei; Wang, Wei-Te

    2013-01-01

    To investigate the feasibility of grayscale quantitative diagnostic method for biceps tendinitis and determine the cut-off points of a quantitative biceps ultrasound (US) method to diagnose biceps tendinitis. Design. Prospective cross-sectional case controlled study. Outpatient rehabilitation service. A total of 336 shoulder pain patients with suspected biceps tendinitis were recruited in this prospective observational study. The grayscale pixel data of the range of interest (ROI) were obtained for both the transverse and longitudinal views of the biceps US. A total of 136 patients were classified with biceps tendinitis, and 200 patients were classified as not having biceps tendinitis based on the diagnostic criteria. Based on the Youden index, the cut-off points were determined as 26.85 for the transverse view and 21.25 for the longitudinal view of the standard deviation (StdDev) of the ROI values, respectively. When the ROI evaluation of the US surpassed the cut-off point, the sensitivity was 68% and the specificity was 90% in the StdDev of the transverse view, and the sensitivity was 81% and the specificity was 73% in the StdDev of the longitudinal view to diagnose biceps tendinitis. For equivocal cases or inexperienced sonographers, our study provides a more objective method for diagnosing biceps tendinitis in shoulder pain patients.

  7. Contrast-enhanced 3T MR Perfusion of Musculoskeletal Tumours: T1 Value Heterogeneity Assessment and Evaluation of the Influence of T1 Estimation Methods on Quantitative Parameters.

    PubMed

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain

    2017-12-01

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.

  8. Time-resolved quantitative-phase microscopy of laser-material interactions using a wavefront sensor.

    PubMed

    Gallais, Laurent; Monneret, Serge

    2016-07-15

    We report on a simple and efficient technique based on a wavefront sensor to obtain time-resolved amplitude and phase images of laser-material interactions. The main interest of the technique is to obtain quantitative self-calibrated phase measurements in one shot at the femtosecond time-scale, with high spatial resolution. The technique is used for direct observation and quantitative measurement of the Kerr effect in a fused silica substrate and free electron generation by photo-ionization processes in an optical coating.

  9. Concomitant semi-quantitative and visual analysis improves the predictive value on treatment outcome of interim 18F-fluorodeoxyglucose / Positron Emission Tomography in advanced Hodgkin lymphoma.

    PubMed

    Biggi, Alberto; Bergesio, Fabrizio; Chauvie, Stephane; Bianchi, Andrea; Menga, Massimo; Fallanca, Federico; Hutchings, Martin; Gregianin, Michele; Meignan, Michel; Gallamini, Andrea

    2017-07-27

    Qualitative assessment using the Deauville five-point scale (DS) is the gold standard for interim and end-of treatment PET interpretation in lymphoma. In the present study we assessed the reliability and the prognostic value of different semi- quantitative (SQ) parameters in comparison with DS for interim PET (iPET) interpretation in Hodgkin lymphoma (HL). A cohort of 82 out of 260 patients with advanced stage HL enrolled in the International Validation Study (IVS), scored as 3 to 5 by the expert panel was included in the present report. Two nuclear medicine physicians blinded to patient history, clinical data and treatment outcome reviewed independently the iPET using the following parameters: DS, SUVMax, SUVPeak of the most active lesion, QMax (ratio of SUVMax of the lesion to liver SUVMax) and QRes (ratio of SUVPeak of the lesion to liver SUVMean). The optimal sensitivity, specificity, positive and negative predictive value to predict treatment outcome was calculated for all the above parameters with the Receiver Operator Characteristics analysis. The prognostic value of all parameters were similar, the best cut-off value being 4 for DS (Area Under the Curve, AUC, 0.81 CI95%: 0.72-0.90), 3.81 for SUVMax (AUC 0.82 CI95%: 0.73-0.91), 3.20 for SUVPeak (AUC 0.86 CI95%: 0.77-0.94), 1.07 for QMax (AUC 0.84 CI95%: 0.75-0.93) and 1.38 for QRes (AUC 0.84 CI95%: 0.75-0.93). The reproducibility of different parameters was similar as the inter-observer variability measured with Cohen's kappa were 0.93 (95% CI 0.84-1.01) for the DS, 0.88 (0.77-0.98) for SUVMax, 0.82 (0.70-0.95) for SUVPeak, 0.85 (0.74-0.97) for QRes and 0.78 (0.65-0.92) for QMax. Due to the high specificity of SUVPeak (0.87) and to the good sensitivity of DS (0.86), upon the use of both parameters the positive predictive value increased from 0.65 of the DS alone to 0.79. When both parameters were positive in iPET, 3-years Failure-Free Survival (FFS) was significantly lower compared to patients whose iPET was

  10. The amount effect and marginal value.

    PubMed

    Rachlin, Howard; Arfer, Kodi B; Safin, Vasiliy; Yen, Ming

    2015-07-01

    The amount effect of delay discounting (by which the value of larger reward amounts is discounted by delay at a lower rate than that of smaller amounts) strictly implies that value functions (value as a function of amount) are steeper at greater delays than they are at lesser delays. That is, the amount effect and the difference in value functions at different delays are actually a single empirical finding. Amount effects of delay discounting are typically found with choice experiments. Value functions for immediate rewards have been empirically obtained by direct judgment. (Value functions for delayed rewards have not been previously obtained.) The present experiment obtained value functions for both immediate and delayed rewards by direct judgment and found them to be steeper when the rewards were delayed--hence, finding an amount effect with delay discounting. © Society for the Experimental Analysis of Behavior.

  11. Development and validation of open-source software for DNA mixture interpretation based on a quantitative continuous model

    PubMed Central

    Manabe, Sho; Morimoto, Chie; Hamano, Yuya; Fujimoto, Shuntaro

    2017-01-01

    In criminal investigations, forensic scientists need to evaluate DNA mixtures. The estimation of the number of contributors and evaluation of the contribution of a person of interest (POI) from these samples are challenging. In this study, we developed a new open-source software “Kongoh” for interpreting DNA mixture based on a quantitative continuous model. The model uses quantitative information of peak heights in the DNA profile and considers the effect of artifacts and allelic drop-out. By using this software, the likelihoods of 1–4 persons’ contributions are calculated, and the most optimal number of contributors is automatically determined; this differs from other open-source software. Therefore, we can eliminate the need to manually determine the number of contributors before the analysis. Kongoh also considers allele- or locus-specific effects of biological parameters based on the experimental data. We then validated Kongoh by calculating the likelihood ratio (LR) of a POI’s contribution in true contributors and non-contributors by using 2–4 person mixtures analyzed through a 15 short tandem repeat typing system. Most LR values obtained from Kongoh during true-contributor testing strongly supported the POI’s contribution even for small amounts or degraded DNA samples. Kongoh correctly rejected a false hypothesis in the non-contributor testing, generated reproducible LR values, and demonstrated higher accuracy of the estimated number of contributors than another software based on the quantitative continuous model. Therefore, Kongoh is useful in accurately interpreting DNA evidence like mixtures and small amounts or degraded DNA samples. PMID:29149210

  12. Development and validation of open-source software for DNA mixture interpretation based on a quantitative continuous model.

    PubMed

    Manabe, Sho; Morimoto, Chie; Hamano, Yuya; Fujimoto, Shuntaro; Tamaki, Keiji

    2017-01-01

    In criminal investigations, forensic scientists need to evaluate DNA mixtures. The estimation of the number of contributors and evaluation of the contribution of a person of interest (POI) from these samples are challenging. In this study, we developed a new open-source software "Kongoh" for interpreting DNA mixture based on a quantitative continuous model. The model uses quantitative information of peak heights in the DNA profile and considers the effect of artifacts and allelic drop-out. By using this software, the likelihoods of 1-4 persons' contributions are calculated, and the most optimal number of contributors is automatically determined; this differs from other open-source software. Therefore, we can eliminate the need to manually determine the number of contributors before the analysis. Kongoh also considers allele- or locus-specific effects of biological parameters based on the experimental data. We then validated Kongoh by calculating the likelihood ratio (LR) of a POI's contribution in true contributors and non-contributors by using 2-4 person mixtures analyzed through a 15 short tandem repeat typing system. Most LR values obtained from Kongoh during true-contributor testing strongly supported the POI's contribution even for small amounts or degraded DNA samples. Kongoh correctly rejected a false hypothesis in the non-contributor testing, generated reproducible LR values, and demonstrated higher accuracy of the estimated number of contributors than another software based on the quantitative continuous model. Therefore, Kongoh is useful in accurately interpreting DNA evidence like mixtures and small amounts or degraded DNA samples.

  13. Serial semi-quantitative measurement of fecal calprotectin in patients with ulcerative colitis in remission.

    PubMed

    Garcia-Planella, Esther; Mañosa, Míriam; Chaparro, María; Beltrán, Belén; Barreiro-de-Acosta, Manuel; Gordillo, Jordi; Ricart, Elena; Bermejo, Fernando; García-Sánchez, Valle; Piqueras, Marta; Llaó, Jordina; Gisbert, Javier P; Cabré, Eduard; Domènech, Eugeni

    2018-02-01

    Fecal calprotectin (FC) correlates with clinical and endoscopic activity in ulcerative colitis (UC), and it is a good predictor of relapse. However, its use in clinical practice is constrained by the need for the patient to deliver stool samples, and for their handling and processing in the laboratory. The availability of hand held devices might spread the use of FC in clinical practice. To evaluate the usefulness of a rapid semi-quantitative test of FC in predicting relapse in patients with UC in remission. Prospective, multicenter study that included UC patients in clinical remission for ≥6 months on maintenance treatment with mesalamine. Patients were evaluated clinically and semi-quantitative FC was measured using a monoclonal immunochromatography rapid test at baseline and every three months until relapse or 12 months of follow-up. One hundred and ninety-one patients had at least one determination of FC. At the end of follow-up, 33 patients (17%) experienced clinical relapse. Endoscopic activity at baseline (p = .043) and having had at least one FC > 60 μg/g during the study period (p = .03) were associated with a higher risk of relapse during follow-up. We obtained a total of 636 semi-quantitative FC determinations matched with a three-month follow-up clinical assessment. Having undetectable FC was inversely associated with early relapse (within three months), with a negative predictive value of 98.6% and a sensitivity of 93.9%. Serial, rapid semi-quantitative measurement of FC may be a useful, easy and cheap monitoring tool for patients with UC in remission.

  14. Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.

    PubMed

    Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo

    2015-01-01

    We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.

  15. Performance of the New Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: conversion to international units and comparison with the Roche COBAS Amplicor HCV Monitor, Version 2.0, assay.

    PubMed

    Beld, Marcel; Sentjens, Roel; Rebers, Sjoerd; Weegink, Christine; Weel, Jan; Sol, Cees; Boom, René

    2002-03-01

    We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0 bDNA assay has a linear dynamic range of 2.5 x 10(3) to 4.0 x 10(7) HCV RNA copies per ml (c/ml). The performance of the HCV 3.0 bDNA assay was evaluated using three different test panels. An overall specificity of 96.8% relative to the detection limit of the HCV 3.0 bDNA assay was found. The intra- and interrun reproducibilities for both the dilution panel and the NAP (AcroMetrix, Benicia, Calif.) panel were consistent with coefficients of variation of less than 9%. Quantitation with the HCV 3.0 bDNA assay was linear over the entire range of both panels (ranges of 4.4 x 10(3) to 3.5 x 10(6) c/ml and 5 x 10(3) to 2 x 10(6) IU/ml, respectively), with correlation coefficients of 0.999, slopes close to one, and intercepts close to zero. The regression equation indicated that 1 IU corresponded to about 4.8 copies of HCV RNA. A correlation coefficient of 0.941 was found for HCV RNA values (in international units per milliliter) obtained from the HCV 3.0 bDNA assay and the HCV Monitor version 2.0 assay (HCV Monitor 2.0 assay) (Roche Diagnostic Systems, Branchburg, N.J.). Quantitative results obtained close to the lower limit of the HCV 3.0 bDNA assay might imply that its lower limit should be reconsidered and raised, if necessary. It appeared that quantitation values obtained from the HCV Monitor 2.0 assay of between 5 x 10(2) and 10(5) IU/ml were in general higher than those obtained from the HCV 3.0 bDNA assay, whereas values obtained from the HCV Monitor 2.0 assay were underestimated for samples with HCV RNA levels above 10(5) IU/ml.

  16. Performance of the New Bayer VERSANT HCV RNA 3.0 Assay for Quantitation of Hepatitis C Virus RNA in Plasma and Serum: Conversion to International Units and Comparison with the Roche COBAS Amplicor HCV Monitor, Version 2.0, Assay

    PubMed Central

    Beld, Marcel; Sentjens, Roel; Rebers, Sjoerd; Weegink, Christine; Weel, Jan; Sol, Cees; Boom, René

    2002-01-01

    We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0 bDNA assay has a linear dynamic range of 2.5 × 103 to 4.0 × 107 HCV RNA copies per ml (c/ml). The performance of the HCV 3.0 bDNA assay was evaluated using three different test panels. An overall specificity of 96.8% relative to the detection limit of the HCV 3.0 bDNA assay was found. The intra- and interrun reproducibilities for both the dilution panel and the NAP (AcroMetrix, Benicia, Calif.) panel were consistent with coefficients of variation of less than 9%. Quantitation with the HCV 3.0 bDNA assay was linear over the entire range of both panels (ranges of 4.4 × 103 to 3.5 × 106 c/ml and 5 × 103 to 2 × 106 IU/ml, respectively), with correlation coefficients of 0.999, slopes close to one, and intercepts close to zero. The regression equation indicated that 1 IU corresponded to about 4.8 copies of HCV RNA. A correlation coefficient of 0.941 was found for HCV RNA values (in international units per milliliter) obtained from the HCV 3.0 bDNA assay and the HCV Monitor version 2.0 assay (HCV Monitor 2.0 assay) (Roche Diagnostic Systems, Branchburg, N.J.). Quantitative results obtained close to the lower limit of the HCV 3.0 bDNA assay might imply that its lower limit should be reconsidered and raised, if necessary. It appeared that quantitation values obtained from the HCV Monitor 2.0 assay of between 5 × 102 and 105 IU/ml were in general higher than those obtained from the HCV 3.0 bDNA assay, whereas values obtained from the HCV Monitor 2.0 assay were underestimated for samples with HCV RNA levels above 105 IU/ml. PMID:11880394

  17. An integrative strategy for quantitative analysis of the N-glycoproteome in complex biological samples

    PubMed Central

    2014-01-01

    Background The complexity of protein glycosylation makes it difficult to characterize glycosylation patterns on a proteomic scale. In this study, we developed an integrated strategy for comparatively analyzing N-glycosylation/glycoproteins quantitatively from complex biological samples in a high-throughput manner. This strategy entailed separating and enriching glycopeptides/glycoproteins using lectin affinity chromatography, and then tandem labeling them with 18O/16O to generate a mass shift of 6 Da between the paired glycopeptides, and finally analyzing them with liquid chromatography-mass spectrometry (LC-MS) and the automatic quantitative method we developed based on Mascot Distiller. Results The accuracy and repeatability of this strategy were first verified using standard glycoproteins; linearity was maintained within a range of 1:10–10:1. The peptide concentration ratios obtained by the self-build quantitative method were similar to both the manually calculated and theoretical values, with a standard deviation (SD) of 0.023–0.186 for glycopeptides. The feasibility of the strategy was further confirmed with serum from hepatocellular carcinoma (HCC) patients and healthy individuals; the expression of 44 glycopeptides and 30 glycoproteins were significantly different between HCC patient and control serum. Conclusions This strategy is accurate, repeatable, and efficient, and may be a useful tool for identification of disease-related N-glycosylation/glycoprotein changes. PMID:24428921

  18. Hydrophobic ionic liquids for quantitative bacterial cell lysis with subsequent DNA quantification.

    PubMed

    Fuchs-Telka, Sabine; Fister, Susanne; Mester, Patrick-Julian; Wagner, Martin; Rossmanith, Peter

    2017-02-01

    DNA is one of the most frequently analyzed molecules in the life sciences. In this article we describe a simple and fast protocol for quantitative DNA isolation from bacteria based on hydrophobic ionic liquid supported cell lysis at elevated temperatures (120-150 °C) for subsequent PCR-based analysis. From a set of five hydrophobic ionic liquids, 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide was identified as the most suitable for quantitative cell lysis and DNA extraction because of limited quantitative PCR inhibition by the aqueous eluate as well as no detectable DNA uptake. The newly developed method was able to efficiently lyse Gram-negative bacterial cells, whereas Gram-positive cells were protected by their thick cell wall. The performance of the final protocol resulted in quantitative DNA extraction efficiencies for Gram-negative bacteria similar to those obtained with a commercial kit, whereas the number of handling steps, and especially the time required, was dramatically reduced. Graphical Abstract After careful evaluation of five hydrophobic ionic liquids, 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ([BMPyr + ][Ntf 2 - ]) was identified as the most suitable ionic liquid for quantitative cell lysis and DNA extraction. When used for Gram-negative bacteria, the protocol presented is simple and very fast and achieves DNA extraction efficiencies similar to those obtained with a commercial kit. ddH 2 O double-distilled water, qPCR quantitative PCR.

  19. Correlation of quantitative computed tomographic subchondral bone density and ash density in horses.

    PubMed

    Drum, M G; Les, C M; Park, R D; Norrdin, R W; McIlwraith, C W; Kawcak, C E

    2009-02-01

    The purpose of this study was to compare subchondral bone density obtained using quantitative computed tomography with ash density values from intact equine joints, and to determine if there are measurable anatomic variations in mean subchondral bone density. Five adult equine metacarpophalangeal joints were scanned with computed tomography (CT), disarticulated, and four 1-cm(3) regions of interest (ROI) cut from the distal third metacarpal bone. Bone cubes were ashed, and percent mineralization and ash density were recorded. Three-dimensional models were created of the distal third metacarpal bone from CT images. Four ROIs were measured on the distal aspect of the third metacarpal bone at axial and abaxial sites of the medial and lateral condyles for correlation with ash samples. Overall correlations of mean quantitative CT (QCT) density with ash density (r=0.82) and percent mineralization (r=0.93) were strong. There were significant differences between abaxial and axial ROIs for mean QCT density, percent bone mineralization and ash density (p<0.05). QCT appears to be a good measure of bone density in equine subchondral bone. Additionally, differences existed between axial and abaxial subchondral bone density in the equine distal third metacarpal bone.

  20. Validation of PCR methods for quantitation of genetically modified plants in food.

    PubMed

    Hübner, P; Waiblinger, H U; Pietsch, K; Brodmann, P

    2001-01-01

    For enforcement of the recently introduced labeling threshold for genetically modified organisms (GMOs) in food ingredients, quantitative detection methods such as quantitative competitive (QC-PCR) and real-time PCR are applied by official food control laboratories. The experiences of 3 European food control laboratories in validating such methods were compared to describe realistic performance characteristics of quantitative PCR detection methods. The limit of quantitation (LOQ) of GMO-specific, real-time PCR was experimentally determined to reach 30-50 target molecules, which is close to theoretical prediction. Starting PCR with 200 ng genomic plant DNA, the LOQ depends primarily on the genome size of the target plant and ranges from 0.02% for rice to 0.7% for wheat. The precision of quantitative PCR detection methods, expressed as relative standard deviation (RSD), varied from 10 to 30%. Using Bt176 corn containing test samples and applying Bt176 specific QC-PCR, mean values deviated from true values by -7to 18%, with an average of 2+/-10%. Ruggedness of real-time PCR detection methods was assessed in an interlaboratory study analyzing commercial, homogeneous food samples. Roundup Ready soybean DNA contents were determined in the range of 0.3 to 36%, relative to soybean DNA, with RSDs of about 25%. Taking the precision of quantitative PCR detection methods into account, suitable sample plans and sample sizes for GMO analysis are suggested. Because quantitative GMO detection methods measure GMO contents of samples in relation to reference material (calibrants), high priority must be given to international agreements and standardization on certified reference materials.

  1. Pneumocystis jirovecii (Pj) quantitative PCR to differentiate Pj pneumonia from Pj colonization in immunocompromised patients.

    PubMed

    Maillet, M; Maubon, D; Brion, J P; François, P; Molina, L; Stahl, J P; Epaulard, O; Bosseray, A; Pavese, P

    2014-03-01

    Conventional polymerase chain reaction (PCR) in respiratory samples does not differentiate between Pneumocystis pneumonia (PCP) and Pneumocystis jirovecii (Pj) colonization. We used Pj real-time quantitative PCR (qPCR) with the objective to discriminate PCP from Pj colonization in immunocompromised patients. All positive Pj qPCR [targeting the major surface glycoprotein (MSG) gene] obtained in respiratory samples from immunocompromised patients presenting pneumonia at the Grenoble University Hospital, France, were collected between August 2009 and April 2011. Diagnoses were retrospectively determined by a multidisciplinary group of experts blinded to the Pj qPCR results. Thirty-one bronchoalveolar lavages and four broncho aspirations positive for the Pj qPCR were obtained from 35 immunocompromised patients. Diagnoses of definite, probable, and possible PCP, and pneumonia from another etiology were retrospectively made for 7, 4, 5, and 19 patients, respectively. Copy numbers were significantly higher in the "definite group" (median 465,000 copies/ml) than in the "probable group" (median 38,600 copies/ml), the "possible group" (median 1,032 copies/ml), and the "other diagnosis group" (median 390 copies/ml). With the value of 3,160 copies/ml, the sensitivity and specificity of qPCR for the diagnosis of PCP were 100 % and 70 %, respectively. With the value of 31,600 copies/ml, the sensitivity and specificity were 80 % and 100 %, respectively. The positive predictive value was 100 % for results with more than 31,600 copies/ml and the negative predictive value was 100 % for results with fewer than 3,160 copies/ml. qPCR targeting the MSG gene can be helpful to discriminate PCP from Pj colonization in immunocompromised patients, using two cut-off values, with a gray zone between them.

  2. Quantitative optical metrology with CMOS cameras

    NASA Astrophysics Data System (ADS)

    Furlong, Cosme; Kolenovic, Ervin; Ferguson, Curtis F.

    2004-08-01

    Recent advances in laser technology, optical sensing, and computer processing of data, have lead to the development of advanced quantitative optical metrology techniques for high accuracy measurements of absolute shapes and deformations of objects. These techniques provide noninvasive, remote, and full field of view information about the objects of interest. The information obtained relates to changes in shape and/or size of the objects, characterizes anomalies, and provides tools to enhance fabrication processes. Factors that influence selection and applicability of an optical technique include the required sensitivity, accuracy, and precision that are necessary for a particular application. In this paper, sensitivity, accuracy, and precision characteristics in quantitative optical metrology techniques, and specifically in optoelectronic holography (OEH) based on CMOS cameras, are discussed. Sensitivity, accuracy, and precision are investigated with the aid of National Institute of Standards and Technology (NIST) traceable gauges, demonstrating the applicability of CMOS cameras in quantitative optical metrology techniques. It is shown that the advanced nature of CMOS technology can be applied to challenging engineering applications, including the study of rapidly evolving phenomena occurring in MEMS and micromechatronics.

  3. Regional ADC values of the normal brain: differences due to age, gender, and laterality.

    PubMed

    Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference.

  4. Quantitative phase imaging and complex field reconstruction by pupil modulation differential phase contrast

    PubMed Central

    Lu, Hangwen; Chung, Jaebum; Ou, Xiaoze; Yang, Changhuei

    2016-01-01

    Differential phase contrast (DPC) is a non-interferometric quantitative phase imaging method achieved by using an asymmetric imaging procedure. We report a pupil modulation differential phase contrast (PMDPC) imaging method by filtering a sample’s Fourier domain with half-circle pupils. A phase gradient image is captured with each half-circle pupil, and a quantitative high resolution phase image is obtained after a deconvolution process with a minimum of two phase gradient images. Here, we introduce PMDPC quantitative phase image reconstruction algorithm and realize it experimentally in a 4f system with an SLM placed at the pupil plane. In our current experimental setup with the numerical aperture of 0.36, we obtain a quantitative phase image with a resolution of 1.73μm after computationally removing system aberrations and refocusing. We also extend the depth of field digitally by 20 times to ±50μm with a resolution of 1.76μm. PMID:27828473

  5. WE-G-207-05: Relationship Between CT Image Quality, Segmentation Performance, and Quantitative Image Feature Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, J; Nishikawa, R; Reiser, I

    Purpose: Segmentation quality can affect quantitative image feature analysis. The objective of this study is to examine the relationship between computed tomography (CT) image quality, segmentation performance, and quantitative image feature analysis. Methods: A total of 90 pathology proven breast lesions in 87 dedicated breast CT images were considered. An iterative image reconstruction (IIR) algorithm was used to obtain CT images with different quality. With different combinations of 4 variables in the algorithm, this study obtained a total of 28 different qualities of CT images. Two imaging tasks/objectives were considered: 1) segmentation and 2) classification of the lesion as benignmore » or malignant. Twenty-three image features were extracted after segmentation using a semi-automated algorithm and 5 of them were selected via a feature selection technique. Logistic regression was trained and tested using leave-one-out-cross-validation and its area under the ROC curve (AUC) was recorded. The standard deviation of a homogeneous portion and the gradient of a parenchymal portion of an example breast were used as an estimate of image noise and sharpness. The DICE coefficient was computed using a radiologist’s drawing on the lesion. Mean DICE and AUC were used as performance metrics for each of the 28 reconstructions. The relationship between segmentation and classification performance under different reconstructions were compared. Distributions (median, 95% confidence interval) of DICE and AUC for each reconstruction were also compared. Results: Moderate correlation (Pearson’s rho = 0.43, p-value = 0.02) between DICE and AUC values was found. However, the variation between DICE and AUC values for each reconstruction increased as the image sharpness increased. There was a combination of IIR parameters that resulted in the best segmentation with the worst classification performance. Conclusion: There are certain images that yield better segmentation or

  6. The predictive value of quantitative DCE metrics for immediate therapeutic response of high-intensity focused ultrasound ablation (HIFU) of symptomatic uterine fibroids.

    PubMed

    Wei, Chao; Fang, Xin; Wang, Chuan-Bin; Chen, Yu; Xu, Xiao; Dong, Jiang-Ning

    2017-12-04

    The aim of this study was to investigate the value of quantitative DCE-MRI parameters for predicting the immediate non-perfused volume ratio (NPVR) of HIFU therapy in the treatment of symptomatic uterine fibroids. A total of 78 symptomatic uterine fibroids in 65 female patients were treated with US-HIFU therapy. All patients underwent conventional MRI and DCE-MRI scans 1 day before and 3 days after HIFU treatment. Permeability parameters K trans , K ep , V e , and V p and T1 perfusion parameters BF and BV of pretreatment were measured as a baseline, while NPVR was used to assess immediate ablation efficiency. Data were assigned to NPVR ≧ 70% and NPVR < 70% groups. Then, the predictive performances of different parameters for ablation efficacy were studied to seek the optimal cut-off value, and the length of time to calculate the variable parameters in each case was recorded. (1) It was observed that the pretreatment K trans , K ep , V e , and BF values of the NPVR ≧ 70% group were significantly lower compared to the NPVR < 70% group (p < 0.05). (2) The immediate NPVR was negatively correlated with the K trans , BF, and BV values before HIFU treatment (r = - 0.561, - 0.712, and - 0.528, respectively, p < 0.05 for all). (3) The AUCs of pretreatment K trans , BF, BV values, and K trans combined with BF used to predict the immediate NPVR were 0.810, 0.909, 0.795, and 0.922, respectively (p < 0.05 for all). (4) The mean time to calculate the variable parameters in each case was 7.5 min. Higher K trans , BF, and BV values at baseline DCE-MRI suggested a poor ablation efficacy of HIFU therapy for symptomatic uterine fibroids, while the pretreatment DCE-MRI parameters could be useful biomarkers for predicting the ablation efficacy in select cases. The software used to calculate DCE-MRI parameters was simpler, quicker, and easier to incorporate into clinical practice.

  7. iMet-Q: A User-Friendly Tool for Label-Free Metabolomics Quantitation Using Dynamic Peak-Width Determination

    PubMed Central

    Chang, Hui-Yin; Chen, Ching-Tai; Lih, T. Mamie; Lynn, Ke-Shiuan; Juo, Chiun-Gung; Hsu, Wen-Lian; Sung, Ting-Yi

    2016-01-01

    Efficient and accurate quantitation of metabolites from LC-MS data has become an important topic. Here we present an automated tool, called iMet-Q (intelligent Metabolomic Quantitation), for label-free metabolomics quantitation from high-throughput MS1 data. By performing peak detection and peak alignment, iMet-Q provides a summary of quantitation results and reports ion abundance at both replicate level and sample level. Furthermore, it gives the charge states and isotope ratios of detected metabolite peaks to facilitate metabolite identification. An in-house standard mixture and a public Arabidopsis metabolome data set were analyzed by iMet-Q. Three public quantitation tools, including XCMS, MetAlign, and MZmine 2, were used for performance comparison. From the mixture data set, seven standard metabolites were detected by the four quantitation tools, for which iMet-Q had a smaller quantitation error of 12% in both profile and centroid data sets. Our tool also correctly determined the charge states of seven standard metabolites. By searching the mass values for those standard metabolites against Human Metabolome Database, we obtained a total of 183 metabolite candidates. With the isotope ratios calculated by iMet-Q, 49% (89 out of 183) metabolite candidates were filtered out. From the public Arabidopsis data set reported with two internal standards and 167 elucidated metabolites, iMet-Q detected all of the peaks corresponding to the internal standards and 167 metabolites. Meanwhile, our tool had small abundance variation (≤0.19) when quantifying the two internal standards and had higher abundance correlation (≥0.92) when quantifying the 167 metabolites. iMet-Q provides user-friendly interfaces and is publicly available for download at http://ms.iis.sinica.edu.tw/comics/Software_iMet-Q.html. PMID:26784691

  8. Value Perceptions as Influences upon Engagement

    ERIC Educational Resources Information Center

    Swanson, Lee A.

    2009-01-01

    This study was designed to assess whether changes in stakeholders' perceptions about the value generated by an institution might influence the nature of their engagement with it. Quantitative and qualitative analysis of research data revealed a positive correlation between stakeholders who believed an institution generated social or economic value…

  9. TU-H-CAMPUS-IeP2-01: Quantitative Evaluation of PROPELLER DWI Using QIBA Diffusion Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yung, J; Ai, H; Liu, H

    Purpose: The purpose of this study is to determine the quantitative variability of apparent diffusion coefficient (ADC) values when varying imaging parameters in a diffusion-weighted (DW) fast spin echo (FSE) sequence with Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) k-space trajectory. Methods: Using a 3T MRI scanner, a NIST traceable, quantitative magnetic resonance imaging (MRI) diffusion phantom (High Precision Devices, Inc, Boulder, Colorado) consisting of 13 vials filled with various concentrations of polymer polyvinylpyrrolidone (PVP) in aqueous solution was imaged with a standard Quantitative Imaging Biomarkers Alliance (QIBA) DWI spin echo, echo planar imaging (SE EPI) acquisition. Themore » same phantom was then imaged with a DWI PROPELLER sequence at varying echo train lengths (ETL) of 8, 20, and 32, as well as b-values of 400, 900, and 2000. QIBA DWI phantom analysis software was used to generate ADC maps and create region of interests (ROIs) for quantitative measurements of each vial. Mean and standard deviations of the ROIs were compared. Results: The SE EPI sequence generated ADC values that showed very good agreement with the known ADC values of the phantom (r2 = 0.9995, slope = 1.0061). The ADC values measured from the PROPELLER sequences were inflated, but were highly correlated with an r2 range from 0.8754 to 0.9880. The PROPELLER sequence with an ETL=20 and b-value of 0 and 2000 showed the closest agreement (r2 = 0.9034, slope = 0.9880). Conclusion: The DW PROPELLER sequence is promising for quantitative evaluation of ADC values. A drawback of the PROPELLER sequence is the longer acquisition time. The 180° refocusing pulses may also cause the observed increase in ADC values compared to the standard SE EPI DW sequence. However, the FSE sequence offers an advantage with in-plane motion and geometric distortion which will be investigated in future studies.« less

  10. Quantitative methods to direct exploration based on hydrogeologic information

    USGS Publications Warehouse

    Graettinger, A.J.; Lee, J.; Reeves, H.W.; Dethan, D.

    2006-01-01

    Quantitatively Directed Exploration (QDE) approaches based on information such as model sensitivity, input data covariance and model output covariance are presented. Seven approaches for directing exploration are developed, applied, and evaluated on a synthetic hydrogeologic site. The QDE approaches evaluate input information uncertainty, subsurface model sensitivity and, most importantly, output covariance to identify the next location to sample. Spatial input parameter values and covariances are calculated with the multivariate conditional probability calculation from a limited number of samples. A variogram structure is used during data extrapolation to describe the spatial continuity, or correlation, of subsurface information. Model sensitivity can be determined by perturbing input data and evaluating output response or, as in this work, sensitivities can be programmed directly into an analysis model. Output covariance is calculated by the First-Order Second Moment (FOSM) method, which combines the covariance of input information with model sensitivity. A groundwater flow example, modeled in MODFLOW-2000, is chosen to demonstrate the seven QDE approaches. MODFLOW-2000 is used to obtain the piezometric head and the model sensitivity simultaneously. The seven QDE approaches are evaluated based on the accuracy of the modeled piezometric head after information from a QDE sample is added. For the synthetic site used in this study, the QDE approach that identifies the location of hydraulic conductivity that contributes the most to the overall piezometric head variance proved to be the best method to quantitatively direct exploration. ?? IWA Publishing 2006.

  11. Integral refractive index imaging of flowing cell nuclei using quantitative phase microscopy combined with fluorescence microscopy.

    PubMed

    Dardikman, Gili; Nygate, Yoav N; Barnea, Itay; Turko, Nir A; Singh, Gyanendra; Javidi, Barham; Shaked, Natan T

    2018-03-01

    We suggest a new multimodal imaging technique for quantitatively measuring the integral (thickness-average) refractive index of the nuclei of live biological cells in suspension. For this aim, we combined quantitative phase microscopy with simultaneous 2-D fluorescence microscopy. We used 2-D fluorescence microscopy to localize the nucleus inside the quantitative phase map of the cell, as well as for measuring the nucleus radii. As verified offline by both 3-D confocal fluorescence microscopy and 2-D fluorescence microscopy while rotating the cells during flow, the nucleus of cells in suspension that are not during division can be assumed to be an ellipsoid. The entire shape of a cell in suspension can be assumed to be a sphere. Then, the cell and nucleus 3-D shapes can be evaluated based on their in-plain radii available from the 2-D phase and fluorescent measurements, respectively. Finally, the nucleus integral refractive index profile is calculated. We demonstrate the new technique on cancer cells, obtaining nucleus refractive index values that are lower than those of the cytoplasm, coinciding with recent findings. We believe that the proposed technique has the potential to be used for flow cytometry, where full 3-D refractive index tomography is too slow to be implemented during flow.

  12. Quantitative Discomanometry: Correlation of Intradiscal Pressure Values to Pain Reduction in Patients With Intervertebral Disc Herniation Treated With Percutaneous, Minimally Invasive, Image-Guided Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filippiadis, Dimitrios K., E-mail: dfilippiadis@yahoo.gr; Mazioti, A., E-mail: argyromazioti@yahoo.gr; Papakonstantinou, O., E-mail: sogofianol@gmail.com

    Purpose: To illustrate quantitative discomanometry's (QD) diagnostic efficacy and predictive value in discogenic-pain evaluation in a prospective study correlating intradiscal pressure values with pain reduction after percutaneous image-guided technique (i.e., percutaneous decompression, PD). Materials and Methods: During the last 3 years, 36 patients [21 male and 15 female (mean age 36 {+-} 5.8 years)] with intervertebral disc hernia underwent QD before PD. Under absolute sterilization and fluoroscopy, a mixture of contrast medium and normal saline (3:1 ratio) was injected. A discmonitor performed a constant rate injection and recorded pressure and volume values, thus producing the relative pressure-volume curve. PD wasmore » then performed. Pain reduction and improved mobility were recorded at 3, 12, and 24 months after PD using clinical evaluation and a numeric visual scale (NVS; 0 to 10 units). Results: Mean pain values of 7.5 {+-} 1.9 (range 4 to 8) NVS units were recorded before PD; these decreased to 2.9 {+-} 2.44 at 3 months, 1.0 {+-} 1.9 at 12 months, and 1.0 {+-} 1.9 NVS units at 24 months after PD. Recorded correlations (pressure, volume, significant pain-reduction values) with bilateral statistical significance included a maximum injected volume of 2.4 ml (p = 0.045), P{sub o} < 14 psi [initial pressure required to inject 0.1 ml of the mixture inside the disc (p = 0.05)], P{sub max} {<=} 65 psi [greatest pressure value on the curve (p = 0.018)], and P{sub max} - P{sub o} {<=} 47 psi (p = 0.038). Patients meeting these pressure or volume cut-off points, either independently or as a total, had significant pain reduction (>4 NVS units) after PD. No complications were noted. Conclusions: QD is an efficient technique that may have predictive value for discogenic pain evaluation. It might serve as a useful tool for patient selection for intervertebral disc therapies.« less

  13. Hybrid quantitative MRI using chemical shift displacement and recovery-based simultaneous water and lipid imaging: A preliminary study.

    PubMed

    Ohno, Naoki; Miyati, Tosiaki; Suzuki, Shuto; Kan, Hirohito; Aoki, Toshitaka; Nakamura, Yoshitaka; Hiramatsu, Yuki; Kobayashi, Satoshi; Gabata, Toshifumi

    2018-07-01

    To suppress olefinic signals and enable simultaneous and quantitative estimation of multiple functional parameters associated with water and lipid, we investigated a modified method using chemical shift displacement and recovery-based separation of lipid tissue (SPLIT) involving acquisitions with different inversion times (TIs), echo times (TEs), and b-values. Single-shot diffusion echo-planar imaging (SSD-EPI) with multiple b-values (0-3000 s/mm 2 ) was performed without fat suppression to separate water and lipid images using the chemical shift displacement of lipid signals in the phase-encoding direction. An inversion pulse (TI = 292 ms) was applied to SSD-EPI to remove olefinic signals. Consecutively, SSD-EPI (b = 0 s/mm 2 ) was performed with TI = 0 ms and TE = 31.8 ms for T 1 and T 2 measurements, respectively. Under these conditions, transverse water and lipid images at the maximum diameter of the right calf were obtained in six healthy subjects. T 1 , T 2 , and the apparent diffusion coefficients (ADC) were then calculated for the tibialis anterior (TA), gastrocnemius (GM), and soleus (SL) muscles, tibialis bone marrow (TB), and subcutaneous fat (SF). Perfusion-related (D*) and restricted diffusion coefficients (D) were calculated for the muscles. Lastly, the lipid fractions (LF) of the muscles were determined after T 1 and T 2 corrections. The modified SPLIT method facilitated sufficient separation of water and lipid images of the calf, and the inversion pulse with TI of 292 ms effectively suppressed olefinic signals. All quantitative parameters obtained with the modified SPLIT method were found to be in general agreement with those previously reported in the literature. The modified SPLIT technique enabled sufficient suppression of olefinic signals and simultaneous acquisition of quantitative parameters including diffusion, perfusion, T 1 and T 2 relaxation times, and LF. Copyright © 2018. Published by Elsevier Inc.

  14. Evaluating Values-Centred Pedagogies in Education for Sustainable Development

    ERIC Educational Resources Information Center

    Murray, Paul; Douglas-Dunbar, Andrew; Murray, Sheran

    2014-01-01

    Purpose: The purpose of this paper is to report an attempt to quantitatively evaluate pedagogies designed to help learners clarify their personal values systems in a sustainability context. Design/methodology/approach A pre-test/post-test survey was used to assess shifts in values orientations among 113 undergraduates from the same discipline,…

  15. Normalised quantitative polymerase chain reaction for diagnosis of tuberculosis-associated uveitis.

    PubMed

    Barik, Manas Ranjan; Rath, Soveeta; Modi, Rohit; Rana, Rajkishori; Reddy, Mamatha M; Basu, Soumyava

    2018-05-01

    Polymerase chain reaction (PCR)-based diagnosis of tuberculosis-associated uveitis (TBU) in TB-endemic countries is challenging due to likelihood of latent mycobacterial infection in both immune and non-immune cells. In this study, we investigated normalised quantitative PCR (nqPCR) in ocular fluids (aqueous/vitreous) for diagnosis of TBU in a TB-endemic population. Mycobacterial copy numbers (mpb64 gene) were normalised to host genome copy numbers (RNAse P RNA component H1 [RPPH1] gene) in TBU (n = 16) and control (n = 13) samples (discovery cohort). The mpb64:RPPH1 ratios (normalised value) from each TBU and control sample were tested against the current reference standard i.e. clinically-diagnosed TBU, to generate Receiver Operating Characteristic (ROC) curves. The optimum cut-off value of mpb64:RPPH1 ratio (0.011) for diagnosing TBU was identified from the highest Youden index. This cut-off value was then tested in a different cohort of TBU and controls (validation cohort, 20 cases and 18 controls), where it yielded specificity, sensitivity and diagnostic accuracy of 94.4%, 85.0%, and 89.4% respectively. The above values for conventional quantitative PCR (≥1 copy of mpb64 per reaction) were 61.1%, 90.0%, and 74.3% respectively. Normalisation markedly improved the specificity and diagnostic accuracy of quantitative PCR for diagnosis of TBU. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Quantitation of polymethoxylated flavones in orange juice by high-performance liquid chromatography.

    PubMed

    Rouseff, R L; Ting, S V

    1979-08-01

    A quantitative high-performance liquid chromatographic (HPLC) procedure for the determination of the five major polymethoxylated flavones (PMFs) in orange juice has been developed. It employs a unique ternary solvent system with coupled UV-fluorescence detection. The dual detectors were employed to determine the presence of interfering substances and served as a cross check on quantitation. Stop flow UV and fluorescence scanning was used to identify peaks and determine the presence of impurities. Although all five citrus PMFs fluoresce, some HPLC fluorescence peaks were too small to be of much practical use. All five citrus PMFs could be quantitated satisfactorily with the fixed wavelength UV (313 nm) detector. The HPLC procedure has been used to evaluate each step in the preparation. The optimum extracting solvent was selected and one time consuming step was eliminated, as it was found to be unnecessary. HPLC values for nobiletin and sinensetin are in good agreement with the thin-layer chromatographic (TLC) values in the literature. HPLC values for the other three flavones were considerably lower than those reported in the literature. The HPLC procedure is considerably faster than the TLC procedure with equal or superior precision and accuracy.

  17. Identification and quantitative evaluation of the fiber structure in the pathological tissue using Mueller matrix microscope

    NASA Astrophysics Data System (ADS)

    Zhou, Jialing; He, Honghui; Wang, Ye; Ma, Hui

    2017-02-01

    Fiber structure changes in the various pathological processes, such as the increase of fibrosis in liver diseases, the derangement of fiber in cervical cancer and so on. Currently, clinical pathologic diagnosis is regarded as the golden criterion, but different doctors with discrepancy in knowledge and experience may obtain different conclusions. Up to a point, quantitative evaluation of the fiber structure in the pathological tissue can be of great service to quantitative diagnosis. Mueller matrix measurement is capable of probing comprehensive microstructural information of samples and different wavelength of lights can provide more information. In this paper, we use a Mueller matrix microscope with light sources in six different wavelength. We use unstained, dewaxing liver tissue slices in four stages and the pathological biopsy of the filtration channels from rabbit eyes as samples. We apply the Mueller matrix polar decomposition (MMPD) parameter δ which corresponds to retardance to liver slices. The mean value of abnormal region get bigger when the level of fibrosis get higher and light in short wavelength is more sensitive to the microstructure of fiber. On the other hand, we use the Mueller matrix transformation (MMT) parameter Φ which is associated to the angel of fast axis in the analysis of the slices of the filtration channels from rabbit eyes. The value of kurtosis and the value of skewness shows big difference between new born region and normal region and can reveal the arrangement of fiber. These results indicate that the Mueller matrix microscope has great potential in auxiliary diagnosis.

  18. Multiple internal standard normalization for improving HS-SPME-GC-MS quantitation in virgin olive oil volatile organic compounds (VOO-VOCs) profile.

    PubMed

    Fortini, Martina; Migliorini, Marzia; Cherubini, Chiara; Cecchi, Lorenzo; Calamai, Luca

    2017-04-01

    The commercial value of virgin olive oils (VOOs) strongly depends on their classification, also based on the aroma of the oils, usually evaluated by a panel test. Nowadays, a reliable analytical method is still needed to evaluate the volatile organic compounds (VOCs) and support the standard panel test method. To date, the use of HS-SPME sampling coupled to GC-MS is generally accepted for the analysis of VOCs in VOOs. However, VOO is a challenging matrix due to the simultaneous presence of: i) compounds at ppm and ppb concentrations; ii) molecules belonging to different chemical classes and iii) analytes with a wide range of molecular mass. Therefore, HS-SPME-GC-MS quantitation based upon the use of external standard method or of only a single internal standard (ISTD) for data normalization in an internal standard method, may be troublesome. In this work a multiple internal standard normalization is proposed to overcome these problems and improving quantitation of VOO-VOCs. As many as 11 ISTDs were used for quantitation of 71 VOCs. For each of them the most suitable ISTD was selected and a good linearity in a wide range of calibration was obtained. Except for E-2-hexenal, without ISTD or with an unsuitable ISTD, the linear range of calibration was narrower with respect to that obtained by a suitable ISTD, confirming the usefulness of multiple internal standard normalization for the correct quantitation of VOCs profile in VOOs. The method was validated for 71 VOCs, and then applied to a series of lampante virgin olive oils and extra virgin olive oils. In light of our results, we propose the application of this analytical approach for routine quantitative analyses and to support sensorial analysis for the evaluation of positive and negative VOOs attributes. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Is multidetector CT-based bone mineral density and quantitative bone microstructure assessment at the spine still feasible using ultra-low tube current and sparse sampling?

    PubMed

    Mei, Kai; Kopp, Felix K; Bippus, Rolf; Köhler, Thomas; Schwaiger, Benedikt J; Gersing, Alexandra S; Fehringer, Andreas; Sauter, Andreas; Münzel, Daniela; Pfeiffer, Franz; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B; Baum, Thomas

    2017-12-01

    Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5. Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. • BMD and quantitative bone parameters are assessable in ultra-low-dose in vivo MDCT scans. • Bone mineral density does not change significantly when sparse sampling is applied. • Quantitative trabecular bone microstructure measurements are sensitive to dose reduction. • Osteoporosis subjects could be differentiated even at 10% of original dose. • Radiation exposure should be considered when comparing quantitative bone parameters.

  20. High positive predictive value of Gram stain on catheter-drawn blood samples for the diagnosis of catheter-related bloodstream infection in intensive care neonates.

    PubMed

    Deleers, M; Dodémont, M; Van Overmeire, B; Hennequin, Y; Vermeylen, D; Roisin, S; Denis, O

    2016-04-01

    Catheter-related bloodstream infections (CRBSIs) remain a leading cause of healthcare-associated infections in preterm infants. Rapid and accurate methods for the diagnosis of CRBSIs are needed in order to implement timely and appropriate treatment. A retrospective study was conducted during a 7-year period (2005-2012) in the neonatal intensive care unit of the University Hospital Erasme to assess the value of Gram stain on catheter-drawn blood samples (CDBS) to predict CRBSIs. Both peripheral samples and CDBS were obtained from neonates with clinically suspected CRBSI. Gram stain, automated culture and quantitative cultures on blood agar plates were performed for each sample. The paired quantitative blood culture was used as the standard to define CRBSI. Out of 397 episodes of suspected CRBSIs, 35 were confirmed by a positive ratio of quantitative culture (>5) or a colony count of CDBS culture >100 colony-forming units (CFU)/mL. All but two of the 30 patients who had a CDBS with a positive Gram stain were confirmed as having a CRBSI. Seven patients who had a CDBS with a negative Gram stain were diagnosed as CRBSI. The sensitivity, specificity, positive predictive value and negative predictive value of Gram stain on CDBS were 80, 99.4, 93.3 and 98.1 %, respectively. Gram staining on CDBS is a viable method for rapidly (<1 h) detecting CRBSI without catheter withdrawal.

  1. Combining Quantitative Susceptibility Mapping with Automatic Zero Reference (QSM0) and Myelin Water Fraction Imaging to Quantify Iron-Related Myelin Damage in Chronic Active MS Lesions.

    PubMed

    Yao, Y; Nguyen, T D; Pandya, S; Zhang, Y; Hurtado Rúa, S; Kovanlikaya, I; Kuceyeski, A; Liu, Z; Wang, Y; Gauthier, S A

    2018-02-01

    A hyperintense rim on susceptibility in chronic MS lesions is consistent with iron deposition, and the purpose of this study was to quantify iron-related myelin damage within these lesions as compared with those without rim. Forty-six patients had 2 longitudinal quantitative susceptibility mapping with automatic zero reference scans with a mean interval of 28.9 ± 11.4 months. Myelin water fraction mapping by using fast acquisition with spiral trajectory and T2 prep was obtained at the second time point to measure myelin damage. Mixed-effects models were used to assess lesion quantitative susceptibility mapping and myelin water fraction values. Quantitative susceptibility mapping scans were on average 6.8 parts per billion higher in 116 rim-positive lesions compared with 441 rim-negative lesions ( P < .001). All rim-positive lesions retained a hyperintense rim over time, with increasing quantitative susceptibility mapping values of both the rim and core regions ( P < .001). Quantitative susceptibility mapping scans and myelin water fraction in rim-positive lesions decreased from rim to core, which is consistent with rim iron deposition. Whole lesion myelin water fractions for rim-positive and rim-negative lesions were 0.055 ± 0.07 and 0.066 ± 0.04, respectively. In the mixed-effects model, rim-positive lesions had on average 0.01 lower myelin water fraction compared with rim-negative lesions ( P < .001). The volume of the rim at the initial quantitative susceptibility mapping scan was negatively associated with follow-up myelin water fraction ( P < .01). Quantitative susceptibility mapping rim-positive lesions maintained a hyperintense rim, increased in susceptibility, and had more myelin damage compared with rim-negative lesions. Our results are consistent with the identification of chronic active MS lesions and may provide a target for therapeutic interventions to reduce myelin damage. © 2018 by American Journal of Neuroradiology.

  2. Optical Ptychographic Microscope for Quantitative Bio-Mechanical Imaging

    NASA Astrophysics Data System (ADS)

    Anthony, Nicholas; Cadenazzi, Guido; Nugent, Keith; Abbey, Brian

    The role that mechanical forces play in biological processes such as cell movement and death is becoming of significant interest to further develop our understanding of the inner workings of cells. The most common method used to obtain stress information is photoelasticity which maps a samples birefringence, or its direction dependent refractive indices, using polarized light. However this method only provides qualitative data and for stress information to be useful quantitative data is required. Ptychography is a method for quantitatively determining the phase of a samples complex transmission function. The technique relies upon the collection of multiple overlapping coherent diffraction patterns from laterally displaced points on the sample. The overlap of measurement points provides complementary information that significantly aids in the reconstruction of the complex wavefield exiting the sample and allows for quantitative imaging of weakly interacting specimens. Here we describe recent advances at La Trobe University Melbourne on achieving quantitative birefringence mapping using polarized light ptychography with applications in cell mechanics. Australian Synchrotron, ARC Centre of Excellence for Advanced Molecular Imaging.

  3. Novel quantitative calibration approach for multi-configuration electromagnetic induction (EMI) systems using data acquired at multiple elevations

    NASA Astrophysics Data System (ADS)

    Tan, Xihe; Mester, Achim; von Hebel, Christian; van der Kruk, Jan; Zimmermann, Egon; Vereecken, Harry; van Waasen, Stefan

    2017-04-01

    Electromagnetic induction (EMI) systems offer a great potential to obtain highly resolved layered electrical conductivity models of the shallow subsurface. State-of-the-art inversion procedures require quantitative calibration of EMI data, especially for short-offset EMI systems where significant data shifts are often observed. These shifts are caused by external influences such as the presence of the operator, zero-leveling procedures, the field setup used to move the EMI system and/or cables close by. Calibrations can be performed by using collocated electrical resistivity measurements or taking soil samples, however, these two methods take a lot of time in the field. To improve the calibration in a fast and concise way, we introduce a novel on-site calibration method using a series of apparent electrical conductivity (ECa) values acquired at multiple elevations for a multi-configuration EMI system. No additional instrument or pre-knowledge of the subsurface is needed to acquire quantitative ECa data. By using this calibration method, we correct each coil configuration, i.e., transmitter and receiver coil separation and the horizontal or vertical coplanar (HCP or VCP) coil orientation with a unique set of calibration parameters. A multi-layer soil structure at the corresponding measurement location is inverted together with the calibration parameters using full-solution Maxwell equations for the forward modelling within the shuffled complex evolution (SCE) algorithm to find the optimum solution under a user-defined parameter space. Synthetic data verified the feasibility for calibrating HCP and VCP measurements of a custom made six-coil EMI system with coil offsets between 0.35 m and 1.8 m for quantitative data inversions. As a next step, we applied the calibration approach on acquired experimental data from a bare soil test field (Selhausen, Germany) for the considered EMI system. The obtained calibration parameters were applied to measurements over a 30 m

  4. Multiparametric Quantitative Ultrasound Imaging in Assessment of Chronic Kidney Disease.

    PubMed

    Gao, Jing; Perlman, Alan; Kalache, Safa; Berman, Nathaniel; Seshan, Surya; Salvatore, Steven; Smith, Lindsey; Wehrli, Natasha; Waldron, Levi; Kodali, Hanish; Chevalier, James

    2017-11-01

    To evaluate the value of multiparametric quantitative ultrasound imaging in assessing chronic kidney disease (CKD) using kidney biopsy pathologic findings as reference standards. We prospectively measured multiparametric quantitative ultrasound markers with grayscale, spectral Doppler, and acoustic radiation force impulse imaging in 25 patients with CKD before kidney biopsy and 10 healthy volunteers. Based on all pathologic (glomerulosclerosis, interstitial fibrosis/tubular atrophy, arteriosclerosis, and edema) scores, the patients with CKD were classified into mild (no grade 3 and <2 of grade 2) and moderate to severe (at least 2 of grade 2 or 1 of grade 3) CKD groups. Multiparametric quantitative ultrasound parameters included kidney length, cortical thickness, pixel intensity, parenchymal shear wave velocity, intrarenal artery peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index. We tested the difference in quantitative ultrasound parameters among mild CKD, moderate to severe CKD, and healthy controls using analysis of variance, analyzed correlations of quantitative ultrasound parameters with pathologic scores and the estimated glomerular filtration rate (GFR) using Pearson correlation coefficients, and examined the diagnostic performance of quantitative ultrasound parameters in determining moderate CKD and an estimated GFR of less than 60 mL/min/1.73 m 2 using receiver operating characteristic curve analysis. There were significant differences in cortical thickness, pixel intensity, PSV, and EDV among the 3 groups (all P < .01). Among quantitative ultrasound parameters, the top areas under the receiver operating characteristic curves for PSV and EDV were 0.88 and 0.97, respectively, for determining pathologic moderate to severe CKD, and 0.76 and 0.86 for estimated GFR of less than 60 mL/min/1.73 m 2 . Moderate to good correlations were found for PSV, EDV, and pixel intensity with pathologic scores and estimated GFR. The

  5. Quantitative genetics

    USDA-ARS?s Scientific Manuscript database

    The majority of economically important traits targeted for cotton improvement are quantitatively inherited. In this chapter, the current state of cotton quantitative genetics is described and separated into four components. These components include: 1) traditional quantitative inheritance analysis, ...

  6. Quantitative MRI of kidneys in renal disease.

    PubMed

    Kline, Timothy L; Edwards, Marie E; Garg, Ishan; Irazabal, Maria V; Korfiatis, Panagiotis; Harris, Peter C; King, Bernard F; Torres, Vicente E; Venkatesh, Sudhakar K; Erickson, Bradley J

    2018-03-01

    To evaluate the reproducibility and utility of quantitative magnetic resonance imaging (MRI) sequences for the assessment of kidneys in young adults with normal renal function (eGFR ranged from 90 to 130 mL/min/1.73 m 2 ) and patients with early renal disease (autosomal dominant polycystic kidney disease). This prospective case-control study was performed on ten normal young adults (18-30 years old) and ten age- and sex-matched patients with early renal parenchymal disease (autosomal dominant polycystic kidney disease). All subjects underwent a comprehensive kidney MRI protocol, including qualitative imaging: T1w, T2w, FIESTA, and quantitative imaging: 2D cine phase contrast of the renal arteries, and parenchymal diffusion weighted imaging (DWI), magnetization transfer imaging (MTI), blood oxygen level dependent (BOLD) imaging, and magnetic resonance elastography (MRE). The normal controls were imaged on two separate occasions ≥24 h apart (range 24-210 h) to assess reproducibility of the measurements. Quantitative MR imaging sequences were found to be reproducible. The mean ± SD absolute percent difference between quantitative parameters measured ≥24 h apart were: MTI-derived ratio = 4.5 ± 3.6%, DWI-derived apparent diffusion coefficient (ADC) = 6.5 ± 3.4%, BOLD-derived R2* = 7.4 ± 5.9%, and MRE-derived tissue stiffness = 7.6 ± 3.3%. Compared with controls, the ADPKD patient's non-cystic renal parenchyma (NCRP) had statistically significant differences with regard to quantitative parenchymal measures: lower MTI percent ratios (16.3 ± 4.4 vs. 23.8 ± 1.2, p < 0.05), higher ADCs (2.46 ± 0.20 vs. 2.18 ± 0.10 × 10 -3  mm 2 /s, p < 0.05), lower R2*s (14.9 ± 1.7 vs. 18.1 ± 1.6 s -1 , p < 0.05), and lower tissue stiffness (3.2 ± 0.3 vs. 3.8 ± 0.5 kPa, p < 0.05). Excellent reproducibility of the quantitative measurements was obtained in all cases. Significantly different quantitative MR parenchymal

  7. Influence of sample preparation and identification of subcelluar structures in quantitative holographic phase contrast microscopy

    NASA Astrophysics Data System (ADS)

    Kemper, Björn; Schmidt, Lisa; Przibilla, Sabine; Rommel, Christina; Vollmer, Angelika; Ketelhut, Steffi; Schnekenburger, Jürgen; von Bally, Gert

    2010-04-01

    Digital holographic microscopy (DHM) provides label-free quantitative phase contrast with low demands on sample preparation. Nevertheless, for DHM measurements on fixed cells the mounting medium has to be considered while the phase contrast of living cells may be influenced by the used buffer solution. To quantify these effects, the maximum cell caused phase contrast and the visibility of the nucleoli were analyzed. A second aim of the study was to identify subcellular components in DHM phase contrast images. Therefore, comparative investigations using bright field imaging, DHM and fluorescence microscopy with 4',6- Diamidino-2-phenylindol (DAPI) staining were performed. DAPI-staining visualizes cell components containing DNA. The obtained results demonstrate exemplarily for two tumor cell lines that from DHM phase contrast images of fixed cells in phosphate buffer saline (PBS) cell thickness values are obtained which are comparable to living cells. Furthermore, it is shown that in many cases nucleus components can be identified only by DHM phase contrast.

  8. Ultrasound introscopic image quantitative characteristics for medical diagnosis

    NASA Astrophysics Data System (ADS)

    Novoselets, Mikhail K.; Sarkisov, Sergey S.; Gridko, Alexander N.; Tcheban, Anatoliy K.

    1993-09-01

    The results on computer aided extraction of quantitative characteristics (QC) of ultrasound introscopic images for medical diagnosis are presented. Thyroid gland (TG) images of Chernobil Accident sufferers are considered. It is shown that TG diseases can be associated with some values of selected QCs of random echo distribution in the image. The possibility of these QCs usage for TG diseases recognition in accordance with calculated values is analyzed. The role of speckle noise elimination in the solution of the problem on TG diagnosis is considered too.

  9. Obtaining big data of vegetation using artificial neural network

    NASA Astrophysics Data System (ADS)

    Ise, T.; Minagawa, M.; Onishi, M.

    2017-12-01

    To carry out predictive studies concerning ecosystems, obtaining appropriate datasets is one of the key factors. Recently, applications of neural network such as deep learning have successfully overcome difficulties in data acquisition and added large datasets for predictive science. For example, deep learning is very powerful in identifying and counting people, cars, etc. However, for vegetation science, deep learning has not been widely used. In general, differing from animals, plants have characteristics of modular growth. For example, numbers of leaves and stems which one individual plant typically possesses are not predetermined but change flexibly according to environmental conditions. This is clearly different from that the standard model of human face has predetermined numbers of parts, such as two eyes, one mouth, and so on. This characteristics of plants can make object identification difficult. In this study, a simple but effective technique was used to overcome the difficulty of visual identification of plants, and automated classification of plant types and quantitative analyses were become possible. For instance, when our method was applied to classify bryophytes, one of the most difficult plant types for computer vision due to their amorphous shapes, the performance of identification model was typically over 90% success. With this technology, it may be possible to obtain the big data of plant type, size, density etc. from satellite and/or drone imageries, in a quantitative manner. this will allow progress in predictive biogeosciences.

  10. Paradigm Privilege: Determining the Value of Research in Teacher Education Policy Making.

    ERIC Educational Resources Information Center

    Bales, Barbara L.

    This paper explains that despite the long debate over the relative value of quantitative and qualitative educational research and attempts to talk across disciplines, quantitative research dominates educational policy circles. As a result, quality qualitative research may not enter into educational policy conversations. The paper discusses whether…

  11. Quantitation of peptides from non-invasive skin tapings using isotope dilution and tandem mass spectrometry.

    PubMed

    Reisdorph, Nichole; Armstrong, Michael; Powell, Roger; Quinn, Kevin; Legg, Kevin; Leung, Donald; Reisdorph, Rick

    2018-05-01

    Previous work from our laboratories utilized a novel skin taping method and mass spectrometry-based proteomics to discover clinical biomarkers of skin conditions; these included atopic dermatitis, Staphylococcus aureus colonization, and eczema herpeticum. While suitable for discovery purposes, semi-quantitative proteomics is generally time-consuming and expensive. Furthermore, depending on the method used, discovery-based proteomics can result in high variation and inadequate sensitivity to detect low abundant peptides. Therefore, we strove to develop a rapid, sensitive, and reproducible method to quantitate disease-related proteins from skin tapings. We utilized isotopically-labeled peptides and tandem mass spectrometry to obtain absolute quantitation values on 14 peptides from 7 proteins; these proteins had shown previous importance in skin disease. The method demonstrated good reproducibility, dynamic range, and linearity (R 2  > 0.993) when n = 3 standards were analyzed across 0.05-2.5 pmol. The method was used to determine if differences exist between skin proteins in a small group of atopic versus non-atopic individuals (n = 12). While only minimal differences were found, peptides were detected in all samples and exhibited good correlation between peptides for 5 of the 7 proteins (R 2  = 0.71-0.98). This method can be applied to larger cohorts to further establish the relationships of these proteins to skin disease. Copyright © 2017. Published by Elsevier B.V.

  12. Smoothing of the bivariate LOD score for non-normal quantitative traits.

    PubMed

    Buil, Alfonso; Dyer, Thomas D; Almasy, Laura; Blangero, John

    2005-12-30

    Variance component analysis provides an efficient method for performing linkage analysis for quantitative traits. However, type I error of variance components-based likelihood ratio testing may be affected when phenotypic data are non-normally distributed (especially with high values of kurtosis). This results in inflated LOD scores when the normality assumption does not hold. Even though different solutions have been proposed to deal with this problem with univariate phenotypes, little work has been done in the multivariate case. We present an empirical approach to adjust the inflated LOD scores obtained from a bivariate phenotype that violates the assumption of normality. Using the Collaborative Study on the Genetics of Alcoholism data available for the Genetic Analysis Workshop 14, we show how bivariate linkage analysis with leptokurtotic traits gives an inflated type I error. We perform a novel correction that achieves acceptable levels of type I error.

  13. Quantitative prediction of solvation free energy in octanol of organic compounds.

    PubMed

    Delgado, Eduardo J; Jaña, Gonzalo A

    2009-03-01

    The free energy of solvation, DeltaGS0, in octanol of organic compounds is quantitatively predicted from the molecular structure. The model, involving only three molecular descriptors, is obtained by multiple linear regression analysis from a data set of 147 compounds containing diverse organic functions, namely, halogenated and non-halogenated alkanes, alkenes, alkynes, aromatics, alcohols, aldehydes, ketones, amines, ethers and esters; covering a DeltaGS0 range from about -50 to 0 kJ.mol(-1). The model predicts the free energy of solvation with a squared correlation coefficient of 0.93 and a standard deviation, 2.4 kJ.mol(-1), just marginally larger than the generally accepted value of experimental uncertainty. The involved molecular descriptors have definite physical meaning corresponding to the different intermolecular interactions occurring in the bulk liquid phase. The model is validated with an external set of 36 compounds not included in the training set.

  14. Identification of ginseng root using quantitative X-ray microtomography.

    PubMed

    Ye, Linlin; Xue, Yanling; Wang, Yudan; Qi, Juncheng; Xiao, Tiqiao

    2017-07-01

    The use of X-ray phase-contrast microtomography for the investigation of Chinese medicinal materials is advantageous for its nondestructive, in situ , and three-dimensional quantitative imaging properties. The X-ray phase-contrast microtomography quantitative imaging method was used to investigate the microstructure of ginseng, and the phase-retrieval method is also employed to process the experimental data. Four different ginseng samples were collected and investigated; these were classified according to their species, production area, and sample growth pattern. The quantitative internal characteristic microstructures of ginseng were extracted successfully. The size and position distributions of the calcium oxalate cluster crystals (COCCs), important secondary metabolites that accumulate in ginseng, are revealed by the three-dimensional quantitative imaging method. The volume and amount of the COCCs in different species of the ginseng are obtained by a quantitative analysis of the three-dimensional microstructures, which shows obvious difference among the four species of ginseng. This study is the first to provide evidence of the distribution characteristics of COCCs to identify four types of ginseng, with regard to species authentication and age identification, by X-ray phase-contrast microtomography quantitative imaging. This method is also expected to reveal important relationships between COCCs and the occurrence of the effective medicinal components of ginseng.

  15. 7 CFR 765.353 - Determining market value.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Determining market value. 765.353 Section 765.353... Determining market value. (a) Security proposed for disposition. (1) The Agency will obtain an appraisal of... estimated value is less than $25,000. (b) Security remaining after disposition. The Agency will obtain an...

  16. High dose microCT does not contribute towards improved microPET/CT image quantitative accuracy and can limit longitudinal scanning of small animals

    NASA Astrophysics Data System (ADS)

    McDougald, Wendy A.; Collins, Richard; Green, Mark; Tavares, Adriana A. S.

    2017-10-01

    Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT) imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1) to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2) to evaluate the absorbed dose associated with varying CT parameters. Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA) software implemented by Mediso. Measured Hounsfield Unit (HU) in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC), uniformity and quantitative bias were also measured. Results: Only less than 2% and 1% of CT acquisition protocols yielded water HU values < -80 and air HU values < -840, respectively. Four out of eleven CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration. Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed towards improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.

  17. Myocardial blood flow estimates from dynamic contrast-enhanced magnetic resonance imaging: three quantitative methods

    NASA Astrophysics Data System (ADS)

    Borrazzo, Cristian; Galea, Nicola; Pacilio, Massimiliano; Altabella, Luisa; Preziosi, Enrico; Carnì, Marco; Ciolina, Federica; Vullo, Francesco; Francone, Marco; Catalano, Carlo; Carbone, Iacopo

    2018-02-01

    Dynamic contrast-enhanced cardiovascular magnetic resonance imaging can be used to quantitatively assess the myocardial blood flow (MBF), recovering the tissue impulse response function for the transit of a gadolinium bolus through the myocardium. Several deconvolution techniques are available, using various models for the impulse response. The method of choice may influence the results, producing differences that have not been deeply investigated yet. Three methods for quantifying myocardial perfusion have been compared: Fermi function modelling (FFM), the Tofts model (TM) and the gamma function model (GF), with the latter traditionally used in brain perfusion MRI. Thirty human subjects were studied at rest as well as under cold pressor test stress (submerging hands in ice-cold water), and a single bolus of gadolinium weighing 0.1  ±  0.05 mmol kg-1 was injected. Perfusion estimate differences between the methods were analysed by paired comparisons with Student’s t-test, linear regression analysis, and Bland-Altman plots, as well as also using the two-way ANOVA, considering the MBF values of all patients grouped according to two categories: calculation method and rest/stress conditions. Perfusion estimates obtained by various methods in both rest and stress conditions were not significantly different, and were in good agreement with the literature. The results obtained during the first-pass transit time (20 s) yielded p-values in the range 0.20-0.28 for Student’s t-test, linear regression analysis slopes between 0.98-1.03, and R values between 0.92-1.01. From the Bland-Altman plots, the paired comparisons yielded a bias (and a 95% CI)—expressed as ml/min/g—for FFM versus TM, -0.01 (-0.20, 0.17) or 0.02 (-0.49, 0.52) at rest or under stress respectively, for FFM versus GF, -0.05 (-0.29, 0.20) or  -0.07 (-0.55, 0.41) at rest or under stress, and for TM versus GF, -0.03 (-0.30, 0.24) or  -0.09 (-0.43, 0.26) at rest or under stress. With the

  18. Prognostic Value of Coronary Flow Reserve Obtained on Dobutamine Stress Echocardiography and its Correlation with Target Heart Rate.

    PubMed

    Abreu, José Sebastião de; Rocha, Eduardo Arrais; Machado, Isadora Sucupira; Parahyba, Isabelle O; Rocha, Thais Brito; Paes, Fernando José Villar Nogueira; Diogenes, Tereza Cristina Pinheiro; Abreu, Marília Esther Benevides de; Farias, Ana Gardenia Liberato Ponte; Carneiro, Marcia Maria; Paes, José Nogueira

    2017-05-01

    Normal coronary flow velocity reserve (CFVR) (≥ 2) obtained in the left anterior descending coronary artery (LAD) from transthoracic echocardiography is associated with a good prognosis, but there is no study correlating CFVR with submaximal target heart rate (HR). To evaluate the prognostic value of CFVR obtained in the LAD of patients with preserved (>50%) left ventricular ejection fraction (LVEF) who completed a dobutamine stress echocardiography (DSE), considering target HR. Prospective study of patients with preserved LVEF and CFVR obtained in the LAD who completed DSE. In Group I (GI = 31), normal CFVR was obtained before achieving target HR, and, in Group II (GII = 28), after that. Group III (G III=24) reached target HR, but CFVR was abnormal. Death, acute coronary insufficiency, coronary intervention, coronary angiography without further intervention, and hospitalization were considered events. In 28 ± 4 months, there were 18 (21.6%) events: 6% (2/31) in GI, 18% (5/28) in GII, and 46% (11/24) in GIII. There were 4 (4.8%) deaths, 6 (7.2%) coronary interventions and 8 (9.6%) coronary angiographies without further intervention. In event-free survival by regression analysis, GIII had more events than GI (p < 0.001) and GII (p < 0.045), with no difference between GI and GII (p = 0.160). After adjustment, the only difference was between GIII and GI (p = 0.012). In patients with preserved LVEF and who completed their DSE, normal CFVR obtained before achieving target HR was associated with better prognosis. A reserva de velocidade de fluxo coronariano (RVFC) adequada (≥ 2) obtida na artéria descendente anterior (ADA) através do ecocardiograma transtorácico associa-se a bom prognóstico, mas não há estudo correlacionando-a com a frequência cardíaca (FC) alvo (submáxima). Avaliar o valor prognóstico da RVFC obtida na ADA de pacientes com fração de ejeção do ventrículo esquerdo (FEVE) preservada (>50%) e ecocardiograma sob estresse com dobutamina

  19. Quantitative data standardization of X-ray based densitometry methods

    NASA Astrophysics Data System (ADS)

    Sergunova, K. A.; Petraikin, A. V.; Petrjajkin, F. A.; Akhmad, K. S.; Semenov, D. S.; Potrakhov, N. N.

    2018-02-01

    In the present work is proposed the design of special liquid phantom for assessing the accuracy of quantitative densitometric data. Also are represented the dependencies between the measured bone mineral density values and the given values for different X-ray based densitometry techniques. Shown linear graphs make it possible to introduce correction factors to increase the accuracy of BMD measurement by QCT, DXA and DECT methods, and to use them for standardization and comparison of measurements.

  20. Theoretical foundations for a quantitative approach to paleogenetics. I, II.

    NASA Technical Reports Server (NTRS)

    Holmquist, R.

    1972-01-01

    It is shown that by neglecting the phenomena of multiple hits, back mutation, and chance coincidence errors larger than 100% can be introduced in the calculated value of the average number of nucleotide base differences to be expected between two homologous polynucleotides. Mathematical formulas are derived to correct quantitatively for these effects. It is pointed out that the effects change materially the quantitative aspects of phylogenics, such as the length of the legs of the trees. A number of problems are solved without approximation.-

  1. Near infrared spectroscopy as an on-line method to quantitatively determine glycogen and predict ultimate pH in pre rigor bovine M. longissimus dorsi.

    PubMed

    Lomiwes, D; Reis, M M; Wiklund, E; Young, O A; North, M

    2010-12-01

    The potential of near infrared (NIR) spectroscopy as an on-line method to quantify glycogen and predict ultimate pH (pH(u)) of pre rigor beef M. longissimus dorsi (LD) was assessed. NIR spectra (538 to 1677 nm) of pre rigor LD from steers, cows and bulls were collected early post mortem and measurements were made for pre rigor glycogen concentration and pH(u). Spectral and measured data were combined to develop models to quantify glycogen and predict the pH(u) of pre rigor LD. NIR spectra and pre rigor predicted values obtained from quantitative models were shown to be poorly correlated against glycogen and pH(u) (r(2)=0.23 and 0.20, respectively). Qualitative models developed to categorize each muscle according to their pH(u) were able to correctly categorize 42% of high pH(u) samples. Optimum qualitative and quantitative models derived from NIR spectra found low correlation between predicted values and reference measurements. Copyright © 2010 The American Meat Science Association. Published by Elsevier Ltd.. All rights reserved.

  2. Genomic Quantitative Genetics to Study Evolution in the Wild.

    PubMed

    Gienapp, Phillip; Fior, Simone; Guillaume, Frédéric; Lasky, Jesse R; Sork, Victoria L; Csilléry, Katalin

    2017-12-01

    Quantitative genetic theory provides a means of estimating the evolutionary potential of natural populations. However, this approach was previously only feasible in systems where the genetic relatedness between individuals could be inferred from pedigrees or experimental crosses. The genomic revolution opened up the possibility of obtaining the realized proportion of genome shared among individuals in natural populations of virtually any species, which could promise (more) accurate estimates of quantitative genetic parameters in virtually any species. Such a 'genomic' quantitative genetics approach relies on fewer assumptions, offers a greater methodological flexibility, and is thus expected to greatly enhance our understanding of evolution in natural populations, for example, in the context of adaptation to environmental change, eco-evolutionary dynamics, and biodiversity conservation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    PubMed

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial

  4. Insights into Spray Development from Metered-Dose Inhalers Through Quantitative X-ray Radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mason-Smith, Nicholas; Duke, Daniel J.; Kastengren, Alan L.

    Typical methods to study pMDI sprays employ particle sizing or visible light diagnostics, which suffer in regions of high spray density. X-ray techniques can be applied to pharmaceutical sprays to obtain information unattainable by conventional particle sizing and light-based techniques. We present a technique for obtaining quantitative measurements of spray density in pMDI sprays. A monochromatic focused X-ray beam was used to perform quantitative radiography measurements in the near-nozzle region and plume of HFA-propelled sprays. Measurements were obtained with a temporal resolution of 0.184 ms and spatial resolution of 5 mu m. Steady flow conditions were reached after around 30more » ms for the formulations examined with the spray device used. Spray evolution was affected by the inclusion of ethanol in the formulation and unaffected by the inclusion of 0.1% drug by weight. Estimation of the nozzle exit density showed that vapour is likely to dominate the flow leaving the inhaler nozzle during steady flow. Quantitative measurements in pMDI sprays allow the determination of nozzle exit conditions that are difficult to obtain experimentally by other means. Measurements of these nozzle exit conditions can improve understanding of the atomization mechanisms responsible for pMDI spray droplet and particle formation.« less

  5. [Quantitative and qualitative research methods, can they coexist yet?].

    PubMed

    Hunt, Elena; Lavoie, Anne-Marise

    2011-06-01

    Qualitative design is gaining ground in Nursing research. In spite of a relative progress however, the evidence based practice movement continues to dominate and to underline the exclusive value of quantitative design (particularly that of randomized clinical trials) for clinical decision making. In the actual context convenient to those in power making utilitarian decisions on one hand, and facing nursing criticism of the establishment in favor of qualitative research on the other hand, it is difficult to chose a practical and ethical path that values the nursing role within the health care system, keeping us committed to quality care and maintaining researcher's integrity. Both qualitative and quantitative methods have advantages and disadvantages, and clearly, none of them can, by itself, capture, describe and explain reality adequately. Therefore, a balance between the two methods is needed. Researchers bare responsibility to society and science, and they should opt for the appropriate design susceptible to answering the research question, not promote the design favored by the research funding distributors.

  6. Diffusion-weighted imaging (DWI) of hepatocellular carcinomas: a retrospective analysis of the correlation between qualitative and quantitative DWI and tumour grade.

    PubMed

    Jiang, T; Xu, J H; Zou, Y; Chen, R; Peng, L R; Zhou, Z D; Yang, M

    2017-06-01

    To evaluate the application of qualitative and quantitative diffusion-weighted imaging (DWI) in predicting the histological grade of hepatocellular carcinoma (HCC). Two hundred and fifty-four patients with pathologically confirmed HCC who underwent hepatic DWI on a 1.5-T platform (b = 0, 600 s/mm 2 ) were evaluated retrospectively. HCCs were divided into well-, moderately, and poorly differentiated groups. The relationships between naked-eye signal intensity (SI), SI values, apparent diffusion coefficient (ADC) values on DWI, and the histopathological differentiation of HCC were analysed. Receiver operating characteristic (ROC) curves were drawn to determine the optimal operating points (OOPs) of the SI and ADC values to predict the tumour grade. A weak negative correlation (r=-0.350, p<0.05) was obtained between naked-eye SI and histological grade. There was a significant difference in mean SI values between well- (68.32±31.71) and moderately (102.39±45.55)/poorly (114.55±32.15) differentiated HCC but not between moderately and poorly differentiated HCC. The OOP of the SI value by ROC curve analysis was 66.5 to predict well-differentiated HCC. The mean ADC values of well-, moderately, and poorly differentiated HCC were 1.67±0.13×10 -3 , 1.31±0.16×10 -3 , and 1.08±0.11×10 -3  mm 2 /s, respectively, with significant differences between any two combinations of groups. The OOPs of ADC to diagnose well- and poorly differentiated HCC were 1.5×10 -3 and 1.24×10 -3  mm 2 /s, respectively. Qualitative and quantitative SI and ADC values at DWI may be useful to estimate the histological grade of HCC preoperatively and non-invasively. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. mvp - an open-source preprocessor for cleaning duplicate records and missing values in mass spectrometry data.

    PubMed

    Lee, Geunho; Lee, Hyun Beom; Jung, Byung Hwa; Nam, Hojung

    2017-07-01

    Mass spectrometry (MS) data are used to analyze biological phenomena based on chemical species. However, these data often contain unexpected duplicate records and missing values due to technical or biological factors. These 'dirty data' problems increase the difficulty of performing MS analyses because they lead to performance degradation when statistical or machine-learning tests are applied to the data. Thus, we have developed missing values preprocessor (mvp), an open-source software for preprocessing data that might include duplicate records and missing values. mvp uses the property of MS data in which identical chemical species present the same or similar values for key identifiers, such as the mass-to-charge ratio and intensity signal, and forms cliques via graph theory to process dirty data. We evaluated the validity of the mvp process via quantitative and qualitative analyses and compared the results from a statistical test that analyzed the original and mvp-applied data. This analysis showed that using mvp reduces problems associated with duplicate records and missing values. We also examined the effects of using unprocessed data in statistical tests and examined the improved statistical test results obtained with data preprocessed using mvp.

  8. The Math–Biology Values Instrument: Development of a Tool to Measure Life Science Majors’ Task Values of Using Math in the Context of Biology

    PubMed Central

    Andrews, Sarah E.; Runyon, Christopher; Aikens, Melissa L.

    2017-01-01

    In response to calls to improve the quantitative training of undergraduate biology students, there have been increased efforts to better integrate math into biology curricula. One challenge of such efforts is negative student attitudes toward math, which are thought to be particularly prevalent among biology students. According to theory, students’ personal values toward using math in a biological context will influence their achievement and behavioral outcomes, but a validated instrument is needed to determine this empirically. We developed the Math–Biology Values Instrument (MBVI), an 11-item college-level self-­report instrument grounded in expectancy-value theory, to measure life science students’ interest in using math to understand biology, the perceived usefulness of math to their life science career, and the cost of using math in biology courses. We used a process that integrates multiple forms of validity evidence to show that scores from the MBVI can be used as a valid measure of a student’s value of math in the context of biology. The MBVI can be used by instructors and researchers to help identify instructional strategies that influence math–biology values and understand how math–biology values are related to students’ achievement and decisions to pursue more advanced quantitative-based courses. PMID:28747355

  9. The Value of Mixed Methods Research: A Mixed Methods Study

    ERIC Educational Resources Information Center

    McKim, Courtney A.

    2017-01-01

    The purpose of this explanatory mixed methods study was to examine the perceived value of mixed methods research for graduate students. The quantitative phase was an experiment examining the effect of a passage's methodology on students' perceived value. Results indicated students scored the mixed methods passage as more valuable than those who…

  10. P value and the theory of hypothesis testing: an explanation for new researchers.

    PubMed

    Biau, David Jean; Jolles, Brigitte M; Porcher, Raphaël

    2010-03-01

    In the 1920s, Ronald Fisher developed the theory behind the p value and Jerzy Neyman and Egon Pearson developed the theory of hypothesis testing. These distinct theories have provided researchers important quantitative tools to confirm or refute their hypotheses. The p value is the probability to obtain an effect equal to or more extreme than the one observed presuming the null hypothesis of no effect is true; it gives researchers a measure of the strength of evidence against the null hypothesis. As commonly used, investigators will select a threshold p value below which they will reject the null hypothesis. The theory of hypothesis testing allows researchers to reject a null hypothesis in favor of an alternative hypothesis of some effect. As commonly used, investigators choose Type I error (rejecting the null hypothesis when it is true) and Type II error (accepting the null hypothesis when it is false) levels and determine some critical region. If the test statistic falls into that critical region, the null hypothesis is rejected in favor of the alternative hypothesis. Despite similarities between the two, the p value and the theory of hypothesis testing are different theories that often are misunderstood and confused, leading researchers to improper conclusions. Perhaps the most common misconception is to consider the p value as the probability that the null hypothesis is true rather than the probability of obtaining the difference observed, or one that is more extreme, considering the null is true. Another concern is the risk that an important proportion of statistically significant results are falsely significant. Researchers should have a minimum understanding of these two theories so that they are better able to plan, conduct, interpret, and report scientific experiments.

  11. From information theory to quantitative description of steric effects.

    PubMed

    Alipour, Mojtaba; Safari, Zahra

    2016-07-21

    Immense efforts have been made in the literature to apply the information theory descriptors for investigating the electronic structure theory of various systems. In the present study, the information theoretic quantities, such as Fisher information, Shannon entropy, Onicescu information energy, and Ghosh-Berkowitz-Parr entropy, have been used to present a quantitative description for one of the most widely used concepts in chemistry, namely the steric effects. Taking the experimental steric scales for the different compounds as benchmark sets, there are reasonable linear relationships between the experimental scales of the steric effects and theoretical values of steric energies calculated from information theory functionals. Perusing the results obtained from the information theoretic quantities with the two representations of electron density and shape function, the Shannon entropy has the best performance for the purpose. On the one hand, the usefulness of considering the contributions of functional groups steric energies and geometries, and on the other hand, dissecting the effects of both global and local information measures simultaneously have also been explored. Furthermore, the utility of the information functionals for the description of steric effects in several chemical transformations, such as electrophilic and nucleophilic reactions and host-guest chemistry, has been analyzed. The functionals of information theory correlate remarkably with the stability of systems and experimental scales. Overall, these findings show that the information theoretic quantities can be introduced as quantitative measures of steric effects and provide further evidences of the quality of information theory toward helping theoreticians and experimentalists to interpret different problems in real systems.

  12. Quantitative trait nucleotide analysis using Bayesian model selection.

    PubMed

    Blangero, John; Goring, Harald H H; Kent, Jack W; Williams, Jeff T; Peterson, Charles P; Almasy, Laura; Dyer, Thomas D

    2005-10-01

    Although much attention has been given to statistical genetic methods for the initial localization and fine mapping of quantitative trait loci (QTLs), little methodological work has been done to date on the problem of statistically identifying the most likely functional polymorphisms using sequence data. In this paper we provide a general statistical genetic framework, called Bayesian quantitative trait nucleotide (BQTN) analysis, for assessing the likely functional status of genetic variants. The approach requires the initial enumeration of all genetic variants in a set of resequenced individuals. These polymorphisms are then typed in a large number of individuals (potentially in families), and marker variation is related to quantitative phenotypic variation using Bayesian model selection and averaging. For each sequence variant a posterior probability of effect is obtained and can be used to prioritize additional molecular functional experiments. An example of this quantitative nucleotide analysis is provided using the GAW12 simulated data. The results show that the BQTN method may be useful for choosing the most likely functional variants within a gene (or set of genes). We also include instructions on how to use our computer program, SOLAR, for association analysis and BQTN analysis.

  13. Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Weiskittel, Taylor M.; Vavek, Marissa

    Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. Thesemore » values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction

  14. Extraction efficiency and implications for absolute quantitation of propranolol in mouse brain, liver and kidney thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC ESI-MS/MS

    DOE PAGES

    Kertesz, Vilmos; Weiskittel, Taylor M.; Vavek, Marissa; ...

    2016-06-22

    Currently, absolute quantitation aspects of droplet-based surface sampling for thin tissue analysis using a fully automated autosampler/HPLC-ESI-MS/MS system are not fully evaluated. Knowledge of extraction efficiency and its reproducibility is required to judge the potential of the method for absolute quantitation of analytes from thin tissue sections. Methods: Adjacent thin tissue sections of propranolol dosed mouse brain (10- μm-thick), kidney (10- μm-thick) and liver (8-, 10-, 16- and 24- μm-thick) were obtained. Absolute concentration of propranolol was determined in tissue punches from serial sections using standard bulk tissue extraction protocols and subsequent HPLC separations and tandem mass spectrometric analysis. Thesemore » values were used to determine propranolol extraction efficiency from the tissues with the droplet-based surface sampling approach. Results: Extraction efficiency of propranolol using 10- μm-thick brain, kidney and liver thin tissues using droplet-based surface sampling varied between ~45-63%. Extraction efficiency decreased from ~65% to ~36% with liver thickness increasing from 8 μm to 24 μm. Randomly selecting half of the samples as standards, precision and accuracy of propranolol concentrations obtained for the other half of samples as quality control metrics were determined. Resulting precision ( ±15%) and accuracy ( ±3%) values, respectively, were within acceptable limits. In conclusion, comparative quantitation of adjacent mouse thin tissue sections of different organs and of various thicknesses by droplet-based surface sampling and by bulk extraction of tissue punches showed that extraction efficiency was incomplete using the former method, and that it depended on the organ and tissue thickness. However, once extraction efficiency was determined and applied, the droplet-based approach provided the required quantitation accuracy and precision for assay validations. Furthermore, this means that once the extraction

  15. Prediction of high-stage liver fibrosis using ADC value on diffusion-weighted imaging and quantitative enhancement ratio at the hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI at 1.5 T.

    PubMed

    Harada, Taiyo L; Saito, Kazuhiro; Araki, Yoichi; Matsubayashi, Jun; Nagao, Toshitaka; Sugimoto, Katsutoshi; Tokuuye, Koichi

    2018-05-01

    Background Recently, diffusion-weighted imaging (DWI) and quantitative enhancement ratio measured at the hepatobiliary phase (HBP) of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) has been established as an effective method for evaluating liver fibrosis. Purpose To evaluate which is a more favorable surrogate marker in predicting high-stage liver fibrosis, apparently diffusion coefficient (ADC) value or quantitative enhancement ratio measured on HBP. Material and Methods Eighty-three patients with 99 surgically resected hepatic lesions were enrolled in this study. DWI was performed with b-values of 100 and 800 s/mm 2 . Regions of interest were set on ADC map, and the HBP of Gd-EOB-DTPA-enhanced MRI, to calculate ADC value, liver-to-muscle ratio (LMR), liver-to-spleen ratio (LSR), and contrast enhancement index (CEI) of liver. We compared these parameters between low-stage fibrosis (F0, F1, and F2) and high-stage fibrosis (F3 and F4). Receiver operating characteristic analysis was performed to compare the diagnostic performance when distinguishing low-stage fibrosis from high-stage fibrosis. Results LMR and CEI were significantly lower at high-stage fibrosis than at the low stage ( P < 0.01 and P = 0.04, respectively), whereas LSR did not show a significant difference ( P = 0.053). No significant difference was observed in diagnostic performance between LMR and CEI ( P = 0.185). The best sensitivity and specificity, when an LMR of 2.80 or higher was considered to be low-stage fibrosis, were 82.4% and 75.6%, respectively. ADC value showed no significant differences among fibrosis grades ( P = 0.320). Conclusion LMR and CEI were both adequate surrogate parameters to distinguish high-stage fibrosis from low-stage fibrosis.

  16. Preference-based measures to obtain health state utility values for use in economic evaluations with child-based populations: a review and UK-based focus group assessment of patient and parent choices.

    PubMed

    Wolstenholme, Jane L; Bargo, Danielle; Wang, Kay; Harnden, Anthony; Räisänen, Ulla; Abel, Lucy

    2018-03-21

    No current guidance is available in the UK on the choice of preference-based measure (PBM) that should be used in obtaining health-related quality of life from children. The aim of this study is to review the current usage of PBMs for obtaining health state utility values in child and adolescent populations, and to obtain information on patient and parent-proxy respondent preferences in completing PBMs in the UK. A literature review was conducted to determine which instrument is most frequently used for child-based economic evaluations and whether child or proxy responses are used. Instruments were compared on dimensions, severity levels, elicitation and valuation methods, availability of value sets and validation studies, and the range of utility values generated. Additionally, a series of focus groups of parents and young people (11-20 years) were convened to determine patient and proxy preferences. Five PBMs suitable for child populations were identified, although only the Health Utilities Index 2 (HUI2) and Child Heath Utility 9D (CHU-9D) have UK value sets. 45 papers used PBMs in this population, but many used non-child-specific PBMs. Most respondents were parent proxies, even in adolescent populations. Reported missing data ranged from 0.5 to 49.3%. The focus groups reported their experiences with the EQ-5D-Y and CHU-9D. Both the young persons' group and parent/proxy groups felt that the CHU-9D was more comprehensive but may be harder for a proxy to complete. Some younger children had difficulty understanding the CHU-9D questions, but the young persons' group nonetheless preferred responding directly. The use of PBMs in child populations is increasing, but many studies use PBMs that do not have appropriate value sets. Parent proxies are the most common respondents, but the focus group responses suggest it would be preferred, and may be more informative, for older children to self-report or for child-parent dyads to respond.

  17. Quantitative Boltzmann-Gibbs Principles via Orthogonal Polynomial Duality

    NASA Astrophysics Data System (ADS)

    Ayala, Mario; Carinci, Gioia; Redig, Frank

    2018-06-01

    We study fluctuation fields of orthogonal polynomials in the context of particle systems with duality. We thereby obtain a systematic orthogonal decomposition of the fluctuation fields of local functions, where the order of every term can be quantified. This implies a quantitative generalization of the Boltzmann-Gibbs principle. In the context of independent random walkers, we complete this program, including also fluctuation fields in non-stationary context (local equilibrium). For other interacting particle systems with duality such as the symmetric exclusion process, similar results can be obtained, under precise conditions on the n particle dynamics.

  18. Optical coherence tomography for the quantitative study of cerebrovascular physiology

    PubMed Central

    Srinivasan, Vivek J; Atochin, Dmitriy N; Radhakrishnan, Harsha; Jiang, James Y; Ruvinskaya, Svetlana; Wu, Weicheng; Barry, Scott; Cable, Alex E; Ayata, Cenk; Huang, Paul L; Boas, David A

    2011-01-01

    Doppler optical coherence tomography (DOCT) and OCT angiography are novel methods to investigate cerebrovascular physiology. In the rodent cortex, DOCT flow displays features characteristic of cerebral blood flow, including conservation along nonbranching vascular segments and at branch points. Moreover, DOCT flow values correlate with hydrogen clearance flow values when both are measured simultaneously. These data validate DOCT as a noninvasive quantitative method to measure tissue perfusion over a physiologic range. PMID:21364599

  19. Values of Catholic science educators: Their impact on attitudes of science teaching and learning

    NASA Astrophysics Data System (ADS)

    DeMizio, Joanne Greenwald

    This quantitative study examined the associations between the values held by middle school science teachers in Catholic schools and their attitudes towards science teaching. A total of six value types were studied---theoretical, economic, aesthetic, social, political, and religious. Teachers can have negative, positive, or neutral attitudes towards their teaching that are linked to their teaching practices and student learning. These teachers' attitudes may affect their competence and have a subsequent impact on their students' attitudes and dispositions towards science. Of particular interest was the relationship between science teaching attitudes and religious values. A non-experimental research design was used to obtain responses from 54 teachers with two survey instruments, the Science Teaching Attitude Scale II and the Allport-Vernon-Lindzey Study of Values. Stepwise multiple regression analysis showed that political values were negatively associated with attitudes towards science teaching. Data collected were inconsistent with the existence of any measurable association between religious values and attitudes towards science teaching. This study implies that science teacher preparation programs should adopt a more contextual perspective on science that seeks to develop the valuation of science within a cultural context, as well as programs that enable teachers to identify the influence of their beliefs on instructional actions to optimize the impact of learning new teaching practices that may enhance student learning.

  20. Extended study on the influence of z-value(s) of single and multicomponent time-temperature integrators on the accuracy of quantitative thermal process assessment.

    PubMed

    Guiavarc'h, Yann P; van Loey, Ann M; Hendrickx, Marc E

    2005-02-01

    The possibilities and limitations of single- and multicomponent time-temperature integrators (TTIs) for evaluating the impact of thermal processes on a target food attribute with a Ztarget value different from the zTTI value(s) of the TTI is far from sufficiently documented. In this study, several thousand time-temperature profiles were generated by heat transfer simulations based on a wide range of product and process thermal parameters and considering a Ztarget value of 10 degrees C and a reference temperature of 121.1 degrees C, both currently used to assess the safety of food sterilization processes. These simulations included 15 different Ztarget=10 degrees CF121.1 degrees C values in the range 3 to 60 min. The integration of the time-temperature profiles with ZTTI values of 5.5 to 20.5 degrees C in steps of 1 degrees C allowed generation of a large database containing for each combination of product and process parameters the correction factor to apply to the process value FmultiTTI, which was derived from a single- or multicomponent TTI, to obtain the target process value 10 degrees CF121.1 degrees C. The table and the graph results clearly demonstrated that multicomponent TTIs with z-values close to 10 degrees C can be used as an extremely efficient approach when a single-component TTI with a z-value of 10 degrees C is not available. In particular, a two-component TTI with z1 and z2 values respectively above and below the Ztarget value (10 degrees C in this study) would be the best option for the development of a TTI to assess the safety of sterilized foods. Whatever process and product parameters are used, such a TTI allows proper evaluation of the process value 10 degrees CF121.1 degrees C.

  1. A Quantitative Assessment of Student Performance and Examination Format

    ERIC Educational Resources Information Center

    Davison, Christopher B.; Dustova, Gandzhina

    2017-01-01

    This research study describes the correlations between student performance and examination format in a higher education teaching and research institution. The researchers employed a quantitative, correlational methodology utilizing linear regression analysis. The data was obtained from undergraduate student test scores over a three-year time span.…

  2. Four-hour quantitative real-time polymerase chain reaction-based comprehensive chromosome screening and accumulating evidence of accuracy, safety, predictive value, and clinical efficacy.

    PubMed

    Treff, Nathan R; Scott, Richard T

    2013-03-15

    Embryonic comprehensive chromosomal euploidy may represent a powerful biomarker to improve the success of IVF. However, there are a number of aneuploidy screening strategies to consider, including different technologic platforms with which to interrogate the embryonic DNA, and different embryonic developmental stages from which DNA can be analyzed. Although there are advantages and disadvantages associated with each strategy, a series of experiments producing evidence of accuracy, safety, clinical predictive value, and clinical efficacy indicate that trophectoderm biopsy and quantitative real-time polymerase chain reaction (qPCR)-based comprehensive chromosome screening (CCS) may represent a useful strategy to improve the success of IVF. This Biomarkers in Reproductive Medicine special issue review summarizes the accumulated experience with the development and clinical application of a 4-hour blastocyst qPCR-based CCS technology. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  3. SERS quantitative urine creatinine measurement of human subject

    NASA Astrophysics Data System (ADS)

    Wang, Tsuei Lian; Chiang, Hui-hua K.; Lu, Hui-hsin; Hung, Yung-da

    2005-03-01

    SERS method for biomolecular analysis has several potentials and advantages over traditional biochemical approaches, including less specimen contact, non-destructive to specimen, and multiple components analysis. Urine is an easily available body fluid for monitoring the metabolites and renal function of human body. We developed surface-enhanced Raman scattering (SERS) technique using 50nm size gold colloidal particles for quantitative human urine creatinine measurements. This paper shows that SERS shifts of creatinine (104mg/dl) in artificial urine is from 1400cm-1 to 1500cm-1 which was analyzed for quantitative creatinine measurement. Ten human urine samples were obtained from ten healthy persons and analyzed by the SERS technique. Partial least square cross-validation (PLSCV) method was utilized to obtain the estimated creatinine concentration in clinically relevant (55.9mg/dl to 208mg/dl) concentration range. The root-mean square error of cross validation (RMSECV) is 26.1mg/dl. This research demonstrates the feasibility of using SERS for human subject urine creatinine detection, and establishes the SERS platform technique for bodily fluids measurement.

  4. Automatized image processing of bovine blastocysts produced in vitro for quantitative variable determination

    NASA Astrophysics Data System (ADS)

    Rocha, José Celso; Passalia, Felipe José; Matos, Felipe Delestro; Takahashi, Maria Beatriz; Maserati, Marc Peter, Jr.; Alves, Mayra Fernanda; de Almeida, Tamie Guibu; Cardoso, Bruna Lopes; Basso, Andrea Cristina; Nogueira, Marcelo Fábio Gouveia

    2017-12-01

    There is currently no objective, real-time and non-invasive method for evaluating the quality of mammalian embryos. In this study, we processed images of in vitro produced bovine blastocysts to obtain a deeper comprehension of the embryonic morphological aspects that are related to the standard evaluation of blastocysts. Information was extracted from 482 digital images of blastocysts. The resulting imaging data were individually evaluated by three experienced embryologists who graded their quality. To avoid evaluation bias, each image was related to the modal value of the evaluations. Automated image processing produced 36 quantitative variables for each image. The images, the modal and individual quality grades, and the variables extracted could potentially be used in the development of artificial intelligence techniques (e.g., evolutionary algorithms and artificial neural networks), multivariate modelling and the study of defined structures of the whole blastocyst.

  5. Quantitative Prediction of Solvation Free Energy in Octanol of Organic Compounds

    PubMed Central

    Delgado, Eduardo J.; Jaña, Gonzalo A.

    2009-01-01

    The free energy of solvation, ΔGS0, in octanol of organic compunds is quantitatively predicted from the molecular structure. The model, involving only three molecular descriptors, is obtained by multiple linear regression analysis from a data set of 147 compounds containing diverse organic functions, namely, halogenated and non-halogenated alkanes, alkenes, alkynes, aromatics, alcohols, aldehydes, ketones, amines, ethers and esters; covering a ΔGS0 range from about −50 to 0 kJ·mol−1. The model predicts the free energy of solvation with a squared correlation coefficient of 0.93 and a standard deviation, 2.4 kJ·mol−1, just marginally larger than the generally accepted value of experimental uncertainty. The involved molecular descriptors have definite physical meaning corresponding to the different intermolecular interactions occurring in the bulk liquid phase. The model is validated with an external set of 36 compounds not included in the training set. PMID:19399236

  6. Teachers' Grading Practices: Meaning and Values Assigned

    ERIC Educational Resources Information Center

    Sun, Youyi; Cheng, Liying

    2014-01-01

    This study explores the meaning Chinese secondary school English language teachers associate with the grades they assign to their students, and the value judgements they make in grading. A questionnaire was issued to 350 junior and senior school English language teachers in China. The questionnaire data were analysed both quantitatively and…

  7. [Quantitative analysis of diffusion-weighted magnetic resonance images during chemoradiation therapy for cancer of the cervix uteri: Prognostic role of pretreatment diffusion coefficient values].

    PubMed

    Kharuzhyk, S A

    2015-01-01

    to carry out a quantitative analysis of diffusion-weighted magnetic resonance images (DWI) in cancer of the cervix uteri (CCU) and to estimate the possibility of using pretreatment measured diffusion coefficient (MDC) to predict chemoradiation therapy (CRT). The investigation prospectively enrolled 46 women with morphologically verified Stages IB-IVB CCU. All the women underwent diffusion-weighted magnetic resonance imaging of pelvic organs before and after treatment. A semiautomatic method was used to determine tumor signal intensity (SI) on DWI at b 1000 s/mm2 (SI b1000) and tumor MDC. The reproducibility of MDC measurements was assessed in 16 randomly selected women. The investigators compared the pretreatment quantitative DWI measures in complete and incomplete regression (CR and IR) groups and the presence and absence of tumor progression during a follow-up. An association of MDC with progression-free and overall survivals (PFS and OS) was determined in the patients. A semiautomatic tumor segmentation framework could determine the pretreatment quantitative DMI measures with minimal time spent and high reproducibility. The mean tumor MDC was 0.82 +/- 0.14 x 10(-3) mm2/s. CR and IR were established in 28 and 18 women, respectively. The MDC < or = 0.83 x 10(-3) mm2/s predicted CR with a sensitivity of 64.3% and a specificity of 77.8% (p=0.007). The median follow-up was 47 months (range, 3-82 months). With the MDC < or = 0.86 x 10(-3) mm2/s, 5-year PFS was 74.1% versus 42.1% with a higher MDC (p=0.023) and 5-year OS was 70.4 and 40.6%, respectively (p=0.021). The survival difference was insignificant in relation to the degree of tumor regression. The pretreatment IS at b1000 was of no prognostic value. The pretreatment tumor MDC may serve as a biomarker for predicting the efficiency of CRT for CCU.

  8. [Impact of point spread function correction in standardized uptake value quantitation for positron emission tomography images: a study based on phantom experiments and clinical images].

    PubMed

    Nakamura, Akihiro; Tanizaki, Yasuo; Takeuchi, Miho; Ito, Shigeru; Sano, Yoshitaka; Sato, Mayumi; Kanno, Toshihiko; Okada, Hiroyuki; Torizuka, Tatsuo; Nishizawa, Sadahiko

    2014-06-01

    While point spread function (PSF)-based positron emission tomography (PET) reconstruction effectively improves the spatial resolution and image quality of PET, it may damage its quantitative properties by producing edge artifacts, or Gibbs artifacts, which appear to cause overestimation of regional radioactivity concentration. In this report, we investigated how edge artifacts produce negative effects on the quantitative properties of PET. Experiments with a National Electrical Manufacturers Association (NEMA) phantom, containing radioactive spheres of a variety of sizes and background filled with cold air or water, or radioactive solutions, showed that profiles modified by edge artifacts were reproducible regardless of background μ values, and the effects of edge artifacts increased with increasing sphere-to-background radioactivity concentration ratio (S/B ratio). Profiles were also affected by edge artifacts in complex fashion in response to variable combinations of sphere sizes and S/B ratios; and central single-peak overestimation up to 50% was occasionally noted in relatively small spheres with high S/B ratios. Effects of edge artifacts were obscured in spheres with low S/B ratios. In patient images with a variety of focal lesions, areas of higher radioactivity accumulation were generally more enhanced by edge artifacts, but the effects were variable depending on the size of and accumulation in the lesion. PET images generated using PSF-based reconstruction are therefore not appropriate for the evaluation of SUV.

  9. Optimization of homonuclear 2D NMR for fast quantitative analysis: application to tropine-nortropine mixtures.

    PubMed

    Giraudeau, Patrick; Guignard, Nadia; Hillion, Emilie; Baguet, Evelyne; Akoka, Serge

    2007-03-12

    Quantitative analysis by (1)H NMR is often hampered by heavily overlapping signals that may occur for complex mixtures, especially those containing similar compounds. Bidimensional homonuclear NMR spectroscopy can overcome this difficulty. A thorough review of acquisition and post-processing parameters was carried out to obtain accurate and precise, quantitative 2D J-resolved and DQF-COSY spectra in a much reduced time, thus limiting the spectrometer instabilities in the course of time. The number of t(1) increments was reduced as much as possible, and standard deviation was improved by optimization of spectral width, number of transients, phase cycling and apodization function. Localized polynomial baseline corrections were applied to the relevant chemical shift areas. Our method was applied to tropine-nortropine mixtures. Quantitative J-resolved spectra were obtained in less than 3 min and quantitative DQF-COSY spectra in 12 min, with an accuracy of 3% for J-spectroscopy and 2% for DQF-COSY, and a standard deviation smaller than 1%.

  10. Quantitation of Met tyrosine phosphorylation using MRM-MS.

    PubMed

    Meng, Zhaojing; Srivastava, Apurva K; Zhou, Ming; Veenstra, Timothy

    2013-01-01

    Phosphorylation has long been accepted as a key cellular regulator of cell signaling pathways. The recent development of multiple-reaction monitoring mass spectrometry (MRM-MS) provides a useful tool for measuring the absolute quantity of phosphorylation occupancy at pivotal sites within signaling proteins, even when the phosphorylation sites are in close proximity. Here, we described a targeted quantitation approach to measure the absolute phosphorylation occupancy at Y1234 and Y1235 of Met. The approach is utilized to obtain absolute occupancy of the two phosphorylation sites in the full-length recombinant Met. It is further applied to quantitate the phosphorylation state of these two sites in SNU-5 cells treated with a Met inhibitor.

  11. Advances in the Quantitative Characterization of the Shape of Ash-Sized Pyroclast Populations: Fractal Analyses Coupled to Micro- and Nano-Computed Tomography Techniques

    NASA Astrophysics Data System (ADS)

    Rausch, J.; Vonlanthen, P.; Grobety, B. H.

    2014-12-01

    The quantification of shape parameters in pyroclasts is fundamental to infer the dominant type of magma fragmentation (magmatic vs. phreatomagmatic), as well as the behavior of volcanic plumes and clouds in the atmosphere. In a case study aiming at reconstructing the fragmentation mechanisms triggering maar eruptions in two geologically and compositionally distinctive volcanic fields (West and East Eifel, Germany), the shapes of a large number of ash particle contours obtained from SEM images were analyzed by a dilation-based fractal method. Volcanic particle contours are pseudo-fractals showing mostly two distinct slopes in Richardson plots related to the fractal dimensions D1 (small-scale "textural" dimension) and D2 (large-scale "morphological" dimension). The validity of the data obtained from 2D sections was tested by analysing SEM micro-CT slices of one particle cut in different orientations and positions. Results for West Eifel maar particles yield large D1 values (> 1.023), resembling typical values of magmatic particles, which are characterized by a complex shape, especially at small scales. In contrast, the D1 values of ash particles from one East Eifel maar deposit are much smaller, coinciding with the fractal dimensions obtained from phreatomagmatic end-member particles. These quantitative morphological analyses suggest that the studied maar eruptions were triggered by two different fragmentation processes: phreatomagmatic in the East Eifel and magmatic in the West Eifel. The application of fractal analysis to quantitatively characterize the shape of pyroclasts and the linking of fractal dimensions to specific fragmentation processes has turned out to be a very promising tool for studying the fragmentation history of any volcanic eruption. The next step is to extend morphological analysis of volcanic particles to 3 dimensions. SEM micro-CT, already applied in this study, offers the required resolution, but is not suitable for the analysis of a large

  12. Meaning That Social Studies Teacher Candidates Give to Value Concept and Their Value Rankings

    ERIC Educational Resources Information Center

    Aysegül, Tural

    2018-01-01

    This work determines the role that value education plays in shaping people's personal and social life. This research aims to put forward meaning that social studies teacher candidates give to value concept and its value ranking. To achieve this aim, the opinions of 12 social studies teacher candidates were obtained. During the data collection…

  13. xTract: software for characterizing conformational changes of protein complexes by quantitative cross-linking mass spectrometry.

    PubMed

    Walzthoeni, Thomas; Joachimiak, Lukasz A; Rosenberger, George; Röst, Hannes L; Malmström, Lars; Leitner, Alexander; Frydman, Judith; Aebersold, Ruedi

    2015-12-01

    Chemical cross-linking in combination with mass spectrometry generates distance restraints of amino acid pairs in close proximity on the surface of native proteins and protein complexes. In this study we used quantitative mass spectrometry and chemical cross-linking to quantify differences in cross-linked peptides obtained from complexes in spatially discrete states. We describe a generic computational pipeline for quantitative cross-linking mass spectrometry consisting of modules for quantitative data extraction and statistical assessment of the obtained results. We used the method to detect conformational changes in two model systems: firefly luciferase and the bovine TRiC complex. Our method discovers and explains the structural heterogeneity of protein complexes using only sparse structural information.

  14. Evaluation of shear wave elastography for differential diagnosis of breast lesions: A new qualitative analysis versus conventional quantitative analysis.

    PubMed

    Ren, Wei-Wei; Li, Xiao-Long; Wang, Dan; Liu, Bo-Ji; Zhao, Chong-Ke; Xu, Hui-Xiong

    2018-04-13

    To evaluate a special kind of ultrasound (US) shear wave elastography for differential diagnosis of breast lesions, using a new qualitative analysis (i.e. the elasticity score in the travel time map) compared with conventional quantitative analysis. From June 2014 to July 2015, 266 pathologically proven breast lesions were enrolled in this study. The maximum, mean, median, minimum, and standard deviation of shear wave speed (SWS) values (m/s) were assessed. The elasticity score, a new qualitative feature, was evaluated in the travel time map. The area under the receiver operating characteristic (AUROC) curves were plotted to evaluate the diagnostic performance of both qualitative and quantitative analyses for differentiation of breast lesions. Among all quantitative parameters, SWS-max showed the highest AUROC (0.805; 95% CI: 0.752, 0.851) compared with SWS-mean (0.786; 95% CI:0.732, 0.834; P = 0.094), SWS-median (0.775; 95% CI:0.720, 0.824; P = 0.046), SWS-min (0.675; 95% CI:0.615, 0.731; P = 0.000), and SWS-SD (0.768; 95% CI:0.712, 0.817; P = 0.074). The AUROC of qualitative analysis in this study obtained the best diagnostic performance (0.871; 95% CI: 0.825, 0.909, compared with the best parameter of SWS-max in quantitative analysis, P = 0.011). The new qualitative analysis of shear wave travel time showed the superior diagnostic performance in the differentiation of breast lesions in comparison with conventional quantitative analysis.

  15. Genetic variation maintained in multilocus models of additive quantitative traits under stabilizing selection.

    PubMed Central

    Bürger, R; Gimelfarb, A

    1999-01-01

    Stabilizing selection for an intermediate optimum is generally considered to deplete genetic variation in quantitative traits. However, conflicting results from various types of models have been obtained. While classical analyses assuming a large number of independent additive loci with individually small effects indicated that no genetic variation is preserved under stabilizing selection, several analyses of two-locus models showed the contrary. We perform a complete analysis of a generalization of Wright's two-locus quadratic-optimum model and investigate numerically the ability of quadratic stabilizing selection to maintain genetic variation in additive quantitative traits controlled by up to five loci. A statistical approach is employed by choosing randomly 4000 parameter sets (allelic effects, recombination rates, and strength of selection) for a given number of loci. For each parameter set we iterate the recursion equations that describe the dynamics of gamete frequencies starting from 20 randomly chosen initial conditions until an equilibrium is reached, record the quantities of interest, and calculate their corresponding mean values. As the number of loci increases from two to five, the fraction of the genome expected to be polymorphic declines surprisingly rapidly, and the loci that are polymorphic increasingly are those with small effects on the trait. As a result, the genetic variance expected to be maintained under stabilizing selection decreases very rapidly with increased number of loci. The equilibrium structure expected under stabilizing selection on an additive trait differs markedly from that expected under selection with no constraints on genotypic fitness values. The expected genetic variance, the expected polymorphic fraction of the genome, as well as other quantities of interest, are only weakly dependent on the selection intensity and the level of recombination. PMID:10353920

  16. Quantitative assessment of motor fatigue: normative values and comparison with prior-polio patients.

    PubMed

    Meldrum, Dara; Cahalane, Eibhlis; Conroy, Ronan; Guthrie, Richard; Hardiman, Orla

    2007-06-01

    Motor fatigue is a common complaint of polio survivors and has a negative impact on activities of daily living. The aim of this study was to establish a normative database for hand grip strength and fatigue and to investigate differences between prior-polio subjects and normal controls. Static and dynamic hand grip fatigue and maximum voluntary isometric contraction (MVIC) of hand grip were measured in subjects with a prior history of polio (n = 44) and healthy controls (n = 494). A normative database of fatigue was developed using four indices of analysis. Compared with healthy controls, subjects with prior polio had significantly reduced hand grip strength but developed greater hand grip fatigue in only one fatigue index. Quantitative measurement of fatigue in the prior-polio population may be useful in order to detect change over time and to evaluate treatment strategies.

  17. Quantitative evaluation of Alzheimer's disease

    NASA Astrophysics Data System (ADS)

    Duchesne, S.; Frisoni, G. B.

    2009-02-01

    We propose a single, quantitative metric called the disease evaluation factor (DEF) and assess its efficiency at estimating disease burden in normal, control subjects (CTRL) and probable Alzheimer's disease (AD) patients. The study group consisted in 75 patients with a diagnosis of probable AD and 75 age-matched normal CTRL without neurological or neuropsychological deficit. We calculated a reference eigenspace of MRI appearance from reference data, in which our CTRL and probable AD subjects were projected. We then calculated the multi-dimensional hyperplane separating the CTRL and probable AD groups. The DEF was estimated via a multidimensional weighted distance of eigencoordinates for a given subject and the CTRL group mean, along salient principal components forming the separating hyperplane. We used quantile plots, Kolmogorov-Smirnov and χ2 tests to compare the DEF values and test that their distribution was normal. We used a linear discriminant test to separate CTRL from probable AD based on the DEF factor, and reached an accuracy of 87%. A quantitative biomarker in AD would act as an important surrogate marker of disease status and progression.

  18. Relationship Marketing: A Quantitative Study of Individual Cultural Values as Predictors of Satisfaction Judgments

    ERIC Educational Resources Information Center

    Vickers, Tracy Simone

    2017-01-01

    The economic value of international students to higher education had become important and global competition to attract and retain these lucrative students was fierce. In British Columbia, educational goals were set to ensure that all students receive quality learning experiences and provide maximum economic benefit. Cultural values affect…

  19. Quantitation of benzodiazepine receptor binding with PET [11C]iomazenil and SPECT [123I]iomazenil: preliminary results of a direct comparison in healthy human subjects.

    PubMed

    Bremner, J D; Baldwin, R; Horti, A; Staib, L H; Ng, C K; Tan, P Z; Zea-Ponce, Y; Zoghbi, S; Seibyl, J P; Soufer, R; Charney, D S; Innis, R B

    1999-08-31

    Although positron emission tomography (PET) and single photon emission computed tomography (SPECT) are increasingly used for quantitation of neuroreceptor binding, almost no studies to date have involved a direct comparison of the two. One study found a high level of agreement between the two techniques, although there was a systematic 30% increase in measures of benzodiazepine receptor binding in SPECT compared with PET. The purpose of the current study was to directly compare quantitation of benzodiazepine receptor binding in the same human subjects using PET and SPECT with high specific activity [11C]iomazenil and [123I]iomazenil, respectively. All subjects were administered a single bolus of high specific activity iomazenil labeled with 11C or 123I followed by dynamic PET or SPECT imaging of the brain. Arterial blood samples were obtained for measurement of metabolite-corrected radioligand in plasma. Compartmental modeling was used to fit values for kinetic rate constants of transfer of radioligand between plasma and brain compartments. These values were used for calculation of binding potential (BP = Bmax/Kd) and product of BP and the fraction of free non-protein-bound parent compound (V3'). Mean values for V3' in PET and SPECT were as follows: temporal cortex 23+/-5 and 22+/-3 ml/g, frontal cortex23+/-6 and 22+/-3 ml/g, occipital cortex 28+/-3 and 31+/-5 ml/g, and striatum 4+/-4 and 7+/-4 ml/g. These preliminary findings indicate that PET and SPECT provide comparable results in quantitation of neuroreceptor binding in the human brain.

  20. Usefulness of the automatic quantitative estimation tool for cerebral blood flow: clinical assessment of the application software tool AQCEL.

    PubMed

    Momose, Mitsuhiro; Takaki, Akihiro; Matsushita, Tsuyoshi; Yanagisawa, Shin; Yano, Kesato; Miyasaka, Tadashi; Ogura, Yuka; Kadoya, Masumi

    2011-01-01

    AQCEL enables automatic reconstruction of single-photon emission computed tomogram (SPECT) without image degradation and quantitative analysis of cerebral blood flow (CBF) after the input of simple parameters. We ascertained the usefulness and quality of images obtained by the application software AQCEL in clinical practice. Twelve patients underwent brain perfusion SPECT using technetium-99m ethyl cysteinate dimer at rest and after acetazolamide (ACZ) loading. Images reconstructed using AQCEL were compared with those reconstructed using conventional filtered back projection (FBP) method for qualitative estimation. Two experienced nuclear medicine physicians interpreted the image quality using the following visual scores: 0, same; 1, slightly superior; 2, superior. For quantitative estimation, the mean CBF values of the normal hemisphere of the 12 patients using ACZ calculated by the AQCEL method were compared with those calculated by the conventional method. The CBF values of the 24 regions of the 3-dimensional stereotaxic region of interest template (3DSRT) calculated by the AQCEL method at rest and after ACZ loading were compared to those calculated by the conventional method. No significant qualitative difference was observed between the AQCEL and conventional FBP methods in the rest study. The average score by the AQCEL method was 0.25 ± 0.45 and that by the conventional method was 0.17 ± 0.39 (P = 0.34). There was a significant qualitative difference between the AQCEL and conventional methods in the ACZ loading study. The average score for AQCEL was 0.83 ± 0.58 and that for the conventional method was 0.08 ± 0.29 (P = 0.003). During quantitative estimation using ACZ, the mean CBF values of 12 patients calculated by the AQCEL method were 3-8% higher than those calculated by the conventional method. The square of the correlation coefficient between these methods was 0.995. While comparing the 24 3DSRT regions of 12 patients, the squares of the correlation

  1. 3D quantitative analysis of early decomposition changes of the human face.

    PubMed

    Caplova, Zuzana; Gibelli, Daniele Maria; Poppa, Pasquale; Cummaudo, Marco; Obertova, Zuzana; Sforza, Chiarella; Cattaneo, Cristina

    2018-03-01

    Decomposition of the human body and human face is influenced, among other things, by environmental conditions. The early decomposition changes that modify the appearance of the face may hamper the recognition and identification of the deceased. Quantitative assessment of those changes may provide important information for forensic identification. This report presents a pilot 3D quantitative approach of tracking early decomposition changes of a single cadaver in controlled environmental conditions by summarizing the change with weekly morphological descriptions. The root mean square (RMS) value was used to evaluate the changes of the face after death. The results showed a high correlation (r = 0.863) between the measured RMS and the time since death. RMS values of each scan are presented, as well as the average weekly RMS values. The quantification of decomposition changes could improve the accuracy of antemortem facial approximation and potentially could allow the direct comparisons of antemortem and postmortem 3D scans.

  2. Quantitative and Qualitative Relations between Motivation and Critical-Analytic Thinking

    ERIC Educational Resources Information Center

    Miele, David B.; Wigfield, Allan

    2014-01-01

    The authors examine two kinds of factors that affect students' motivation to engage in critical-analytic thinking. The first, which includes ability beliefs, achievement values, and achievement goal orientations, influences the "quantitative" relation between motivation and critical-analytic thinking; that is, whether students are…

  3. Advanced quantitative measurement methodology in physics education research

    NASA Astrophysics Data System (ADS)

    Wang, Jing

    parts. The first part involves the comparison between item response theory (IRT) and classical test theory (CTT). The two theories both provide test item statistics for educational inferences and decisions. The two theories are both applied to Force Concept Inventory data obtained from students enrolled in The Ohio State University. Effort was made to examine the similarity and difference between the two theories, and the possible explanation to the difference. The study suggests that item response theory is more sensitive to the context and conceptual features of the test items than classical test theory. The IRT parameters provide a better measure than CTT parameters for the educational audience to investigate item features. The second part of the dissertation is on the measure of association for binary data. In quantitative assessment, binary data is often encountered because of its simplicity. The current popular measures of association fail under some extremely unbalanced conditions. However, the occurrence of these conditions is not rare in educational data. Two popular association measures, the Pearson's correlation and the tetrachoric correlation are examined. A new method, model based association is introduced, and an educational testing constraint is discussed. The existing popular methods are compared with the model based association measure with and without the constraint. Connections between the value of association and the context and conceptual features of questions are discussed in detail. Results show that all the methods have their advantages and disadvantages. Special attention to the test and data conditions is necessary. The last part of the dissertation is focused on exploratory factor analysis (EFA). The theoretical advantages of EFA are discussed. Typical misunderstanding and misusage of EFA are explored. The EFA is performed on Lawson's Classroom Test of Scientific Reasoning (LCTSR), a widely used assessment on scientific reasoning skills. The

  4. Mild hypothermia for treatment of diffuse axonal injury: a quantitative analysis of diffusion tensor imaging

    PubMed Central

    Jing, Guojie; Yao, Xiaoteng; Li, Yiyi; Xie, Yituan; Li, Wang#x2019;an; Liu, Kejun; Jing, Yingchao; Li, Baisheng; Lv, Yifan; Ma, Baoxin

    2014-01-01

    Fractional anisotropy values in diffusion tensor imaging can quantitatively reflect the consistency of nerve fibers after brain damage, where higher values generally indicate less damage to nerve fibers. Therefore, we hypothesized that diffusion tensor imaging could be used to evaluate the effect of mild hypothermia on diffuse axonal injury. A total of 102 patients with diffuse axonal injury were randomly divided into two groups: normothermic and mild hypothermic treatment groups. Patient's modified Rankin scale scores 2 months after mild hypothermia were significantly lower than those for the normothermia group. The difference in average fractional anisotropy value for each region of interest before and after mild hypothermia was 1.32-1.36 times higher than the value in the normothermia group. Quantitative assessment of diffusion tensor imaging indicates that mild hypothermia therapy may be beneficial for patients with diffuse axonal injury. PMID:25206800

  5. Feasibility of using 'lung density' values estimated from EIT images for clinical diagnosis of lung abnormalities in mechanically ventilated ICU patients.

    PubMed

    Nebuya, Satoru; Koike, Tomotaka; Imai, Hiroshi; Iwashita, Yoshiaki; Brown, Brian H; Soma, Kazui

    2015-06-01

    This paper reports on the results of a study which compares lung density values obtained from electrical impedance tomography (EIT), clinical diagnosis and CT values (HU) within a region of interest in the lung. The purpose was to assess the clinical use of lung density estimation using EIT data. In 11 patients supported by a mechanical ventilator, the consistency of regional lung density measurements as estimated by EIT was validated to assess the feasibility of its use in intensive care medicine. There were significant differences in regional lung densities recorded in the supine position between normal lungs and diseased lungs associated with pneumonia, atelectasis and pleural effusion (normal; 240 ± 71.7 kg m(-3), pneumonia; 306 ± 38.6 kg m(-3), atelectasis; 497 ± 130 kg m(-3), pleural effusion; 467 ± 113 kg m(-3): Steel-Dwass test, p < 0.05). In addition, in order to compare lung density with CT image pixels, the image resolution of CT images, which was originally 512 × 512 pixels, was changed to 16 × 16 pixels to match that of the EIT images. The results of CT and EIT images from five patients in an intensive care unit showed a correlation coefficient of 0.66 ± 0.13 between the CT values (HU) and the lung density values (kg m(-3)) obtained from EIT. These results indicate that it may be possible to obtain a quantitative value for regional lung density using EIT.

  6. Internet-based questionnaire to self-assess autonomy and obtain a life-at-home services enforcement plan: a retrospective validation study.

    PubMed

    Koskas, P; Scemama, E; Wolfowicz, B

    2015-07-01

    In France, a specially-designed care plan for the elderly is generally based on an interdisciplinary, complex and time-consuming process. The health system assigns care throughout the social and health care services using multiple providers and sites. The free website www.jesuisautonome.fr offers senior citizens and their families an opportunity to assess their own independence at home using a questionnaire in order to obtain a personal, life-at-home, enforcement plan. We aim to examine the correlation between the specially-designed care plan obtained by the usual assessment method and through self-evaluation via the website. Community-dwelling subjects, consulting for the first time from December 2012 to July 2014, were under consideration. Patients were assessed using the Comprehensive Geriatric Assessment (CGA) and also independently during the first consultation; patients and their caregivers were then asked to fill out the questionnaire on the website. The two methods were compared using the Bland-Altman analysis for quantitative values and Kappa values for qualitative values. 73 patients completed the study. Correlation was excellent between parameters that did not include error due to risk to the patient (assistance with bathing and dressing, a nurse for drug distribution, measure of legal protection). Correlation was good with housekeeper hours that involved a financial cost to state social services and families. The GIR (Iso Ressource Groupe), which in France serves as a reference to determine social disability of the elderly, was similar. Our study confirms the potential of the website www.jesuisautonome.fr. to improve the delivery of health and social care services. © The Author(s) 2015.

  7. TU-CD-BRB-04: Automated Radiomic Features Complement the Prognostic Value of VASARI in the TCGA-GBM Dataset

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Velazquez, E Rios; Narayan, V; Grossmann, P

    2015-06-15

    Purpose: To compare the complementary prognostic value of automated Radiomic features to that of radiologist-annotated VASARI features in TCGA-GBM MRI dataset. Methods: For 96 GBM patients, pre-operative MRI images were obtained from The Cancer Imaging Archive. The abnormal tumor bulks were manually defined on post-contrast T1w images. The contrast-enhancing and necrotic regions were segmented using FAST. From these sub-volumes and the total abnormal tumor bulk, a set of Radiomic features quantifying phenotypic differences based on the tumor intensity, shape and texture, were extracted from the post-contrast T1w images. Minimum-redundancy-maximum-relevance (MRMR) was used to identify the most informative Radiomic, VASARI andmore » combined Radiomic-VASARI features in 70% of the dataset (training-set). Multivariate Cox-proportional hazards models were evaluated in 30% of the dataset (validation-set) using the C-index for OS. A bootstrap procedure was used to assess significance while comparing the C-Indices of the different models. Results: Overall, the Radiomic features showed a moderate correlation with the radiologist-annotated VASARI features (r = −0.37 – 0.49); however that correlation was stronger for the Tumor Diameter and Proportion of Necrosis VASARI features (r = −0.71 – 0.69). After MRMR feature selection, the best-performing Radiomic, VASARI, and Radiomic-VASARI Cox-PH models showed a validation C-index of 0.56 (p = NS), 0.58 (p = NS) and 0.65 (p = 0.01), respectively. The combined Radiomic-VASARI model C-index was significantly higher than that obtained from either the Radiomic or VASARI model alone (p = <0.001). Conclusion: Quantitative volumetric and textural Radiomic features complement the qualitative and semi-quantitative annotated VASARI feature set. The prognostic value of informative qualitative VASARI features such as Eloquent Brain and Multifocality is increased with the addition of quantitative volumetric and textural features from

  8. Quantitative light-induced fluorescence technology for quantitative evaluation of tooth wear

    NASA Astrophysics Data System (ADS)

    Kim, Sang-Kyeom; Lee, Hyung-Suk; Park, Seok-Woo; Lee, Eun-Song; de Josselin de Jong, Elbert; Jung, Hoi-In; Kim, Baek-Il

    2017-12-01

    Various technologies used to objectively determine enamel thickness or dentin exposure have been suggested. However, most methods have clinical limitations. This study was conducted to confirm the potential of quantitative light-induced fluorescence (QLF) using autofluorescence intensity of occlusal surfaces of worn teeth according to enamel grinding depth in vitro. Sixteen permanent premolars were used. Each tooth was gradationally ground down at the occlusal surface in the apical direction. QLF-digital and swept-source optical coherence tomography images were acquired at each grinding depth (in steps of 100 μm). All QLF images were converted to 8-bit grayscale images to calculate the fluorescence intensity. The maximum brightness (MB) values of the same sound regions in grayscale images before (MB) and phased values after (MB) the grinding process were calculated. Finally, 13 samples were evaluated. MB increased over the grinding depth range with a strong correlation (r=0.994, P<0.001). In conclusion, the fluorescence intensity of the teeth and grinding depth was strongly correlated in the QLF images. Therefore, QLF technology may be a useful noninvasive tool used to monitor the progression of tooth wear and to conveniently estimate enamel thickness.

  9. Role of serum hepatitis B virus marker quantitation to differentiate natural history phases of HBV infection.

    PubMed

    Wang, Li; Zou, Zhi-Qiang; Wang, Kai; Yu, Ji-Guang; Liu, Xiang-Zhong

    2016-01-01

    The purpose of this study was to characterize roles of serum hepatitis B virus marker quantitation in differentiation of natural phases of HBV infection. A total of 184 chronic hepatitis B (CHB) patients were analyzed retrospectively. Patients were classified into four categories: immune tolerant phase (IT, n = 36), immune clearance phase (IC, n = 81), low-replicative phase (LR, n = 31), and HBeAg-negative hepatitis phase (ENH, n = 36), based on clinical, biochemical, serological, HBV DNA level and histological data. Hepatitis B surface antigen (HBsAg) quantitation in four phases were 4.7 ± 0.2, 3.8 ± 0.5, 2.5 ± 1.2 and 3.4 ± 0.4 log10 IU/mL, respectively. There were significant differences between IT and IC (p < 0.001) and between LR and ENH phases (p < 0.001). Quantitation of hepatitis B e antigen (HBeAg) in IT and IC phases are 1317.9 ± 332.9 and 673.4 ± 562.1 S/CO, respectively (p < 0.001). Hepatitis B core antibody (HBcAb) quantitation in the four groups were 9.48 ± 3.3, 11.7 ± 2.8, 11.2 ± 2.6 and 13.2 ± 2.9 S/CO, respectively. Area under receiver operating characteristic curve (AUCs) of HBsAg and HBeAg at cutoff values of 4.41 log10 IU/mL and 1118.96 S/CO for differentiation of IT and IC phases are 0.984 and 0.828, with sensitivity 94.4 and 85.2 %, specificity 98.7 and 75 %, respectively. AUCs of HBsAg and HBcAb at cutoff values of 3.4 log10 IU/mL and 10.5 S/CO for differentiation of LR and ENT phases are 0.796 and 0.705, with sensitivity 58.1 and 85.7 %, and specificity 94.4 and 46.2 %, respectively. HBsAg quantitation has high predictive value and HBeAg quantitation has moderate predictive value for discriminating IT and IC phase. HBsAg and HBcAb quantitations have moderate predictive values for differentiation of LR and ENH phase.

  10. Quantitative thermal sensory testing -- value of testing for both cold and warm sensation detection in evaluation of small fiber neuropathy.

    PubMed

    Shukla, Garima; Bhatia, Manvir; Behari, Madhuri

    2005-10-01

    Small fiber neuropathy is a common neurological disorder, often missed or ignored by physicians, since examination and routine nerve conduction studies are usually normal in this condition. Many methods including quantitative thermal sensory testing are currently being used for early detection of this condition, so as to enable timely investigation and treatment. This study was conducted to assess the yield of quantitative thermal sensory testing in diagnosis of small fiber neuropathy. We included patients presenting with history suggestive of positive and/or negative sensory symptoms, with normal examination findings, clinically suggestive of small fiber neuropathy, with normal or minimally abnormal routine nerve conduction studies. These patients were subjected to quantitative thermal sensory testing using a Medoc TSA-II Neurosensory analyser at two sites and for two modalities. QST data were compared with those in 120 normal healthy controls. Twenty-five patients (16 males, 9 females) with mean age 46.8+/-16.6 years (range: 21-75 years) were included in the study. The mean duration of symptoms was 1.6+/-1.6 years (range: 3 months-6 years). Eighteen patients (72%) had abnormal thresholds in at least one modality. Thermal thresholds were normal in 7 out of the 25 patients. This study demonstrates that quantitative thermal sensory testing is a fairly sensitive method for detection of small fiber neuropathy especially in patients with normal routine nerve conduction studies.

  11. Quantitative Correlation of 7B04 Aluminum Alloys Pitting Corrosion Morphology Characteristics with Stress Concentration Factor

    NASA Astrophysics Data System (ADS)

    Liu, Zhiguo; Yan, Guangyao; Mu, Zhitao; Li, Xudong

    2018-01-01

    The accelerated pitting corrosion test of 7B04 aluminum alloy specimen was carried out according to the spectrum which simulated airport environment, and the corresponding pitting corrosion damage was obtained and was defined through three parameters A and B and C which respectively denoted the corrosion pit surface length and width and corrosion pit depth. The ratio between three parameters could determine the morphology characteristics of corrosion pits. On this basis the stress concentration factor of typical corrosion pit morphology under certain load conditions was quantitatively analyzed. The research shows that the corrosion pits gradually incline to be ellipse in surface and moderate in depth, and most value of B/A and C/A lies in 1 between 4 and few maximum exceeds 4; The stress concentration factor Kf of corrosion pits is obviously affected by the its morphology, the value of Kf increases with corrosion pits depth increasement under certain corrosion pits surface geometry. Also, the value of Kf decreases with surface width increasement under certain corrosion pits depth. The research conclusion can set theory basis for corrosion fatigue life analysis of aircraft aluminum alloy structure.

  12. A novel gel based vehicle for the delivery of acetylcholine in quantitative sudomotor axon reflex testing.

    PubMed

    Sletten, David M; Kimpinski, Kurt; Weigand, Stephen D; Low, Phillip A

    2009-10-05

    This study describes a novel gel based vehicle for the delivery of acetylcholine (ACh) during quantitative sudomotor axon reflex testing (QSART). A dose and current response study were undertaken on 20 healthy control participants to characterize the efficiency of a gel based vehicle for the delivery of ACh. Values obtained for total sweat volume and latency to sweat onset with gel iontophoresis of ACh during QSART were comparable to previously published normative data using solution based vehicles. Patient discomfort, utilizing the gel based vehicle during the QSART procedure, was minimal. Improvement in iontophoresis using the gel formulation as a vehicle for ACh delivery has the potential to lower the voltage required to overcome skin resistance during QSART and may result in improved patient comfort during the procedure.

  13. Transcending the Quantitative-Qualitative Divide with Mixed Methods Research: A Multidimensional Framework for Understanding Congruence and Completeness in the Study of Values

    ERIC Educational Resources Information Center

    McLafferty, Charles L., Jr.; Slate, John R.; Onwuegbuzie, Anthony J.

    2010-01-01

    Quantitative research dominates published literature in the helping professions. Mixed methods research, which integrates quantitative and qualitative methodologies, has received a lukewarm reception. The authors address the iterative separation that infuses theory, praxis, philosophy, methodology, training, and public perception and propose a…

  14. Quantitative prediction of drug side effects based on drug-related features.

    PubMed

    Niu, Yanqing; Zhang, Wen

    2017-09-01

    Unexpected side effects of drugs are great concern in the drug development, and the identification of side effects is an important task. Recently, machine learning methods are proposed to predict the presence or absence of interested side effects for drugs, but it is difficult to make the accurate prediction for all of them. In this paper, we transform side effect profiles of drugs as their quantitative scores, by summing up their side effects with weights. The quantitative scores may measure the dangers of drugs, and thus help to compare the risk of different drugs. Here, we attempt to predict quantitative scores of drugs, namely the quantitative prediction. Specifically, we explore a variety of drug-related features and evaluate their discriminative powers for the quantitative prediction. Then, we consider several feature combination strategies (direct combination, average scoring ensemble combination) to integrate three informative features: chemical substructures, targets, and treatment indications. Finally, the average scoring ensemble model which produces the better performances is used as the final quantitative prediction model. Since weights for side effects are empirical values, we randomly generate different weights in the simulation experiments. The experimental results show that the quantitative method is robust to different weights, and produces satisfying results. Although other state-of-the-art methods cannot make the quantitative prediction directly, the prediction results can be transformed as the quantitative scores. By indirect comparison, the proposed method produces much better results than benchmark methods in the quantitative prediction. In conclusion, the proposed method is promising for the quantitative prediction of side effects, which may work cooperatively with existing state-of-the-art methods to reveal dangers of drugs.

  15. Relative equilibrium plot improves graphical analysis and allows bias correction of standardized uptake value ratio in quantitative 11C-PiB PET studies.

    PubMed

    Zhou, Yun; Sojkova, Jitka; Resnick, Susan M; Wong, Dean F

    2012-04-01

    Both the standardized uptake value ratio (SUVR) and the Logan plot result in biased distribution volume ratios (DVRs) in ligand-receptor dynamic PET studies. The objective of this study was to use a recently developed relative equilibrium-based graphical (RE) plot method to improve and simplify the 2 commonly used methods for quantification of (11)C-Pittsburgh compound B ((11)C-PiB) PET. The overestimation of DVR in SUVR was analyzed theoretically using the Logan and the RE plots. A bias-corrected SUVR (bcSUVR) was derived from the RE plot. Seventy-eight (11)C-PiB dynamic PET scans (66 from controls and 12 from participants with mild cognitive impaired [MCI] from the Baltimore Longitudinal Study of Aging) were acquired over 90 min. Regions of interest (ROIs) were defined on coregistered MR images. Both the ROI and the pixelwise time-activity curves were used to evaluate the estimates of DVR. DVRs obtained using the Logan plot applied to ROI time-activity curves were used as a reference for comparison of DVR estimates. Results from the theoretic analysis were confirmed by human studies. ROI estimates from the RE plot and the bcSUVR were nearly identical to those from the Logan plot with ROI time-activity curves. In contrast, ROI estimates from DVR images in frontal, temporal, parietal, and cingulate regions and the striatum were underestimated by the Logan plot (controls, 4%-12%; MCI, 9%-16%) and overestimated by the SUVR (controls, 8%-16%; MCI, 16%-24%). This bias was higher in the MCI group than in controls (P < 0.01) but was not present when data were analyzed using either the RE plot or the bcSUVR. The RE plot improves pixelwise quantification of (11)C-PiB dynamic PET, compared with the conventional Logan plot. The bcSUVR results in lower bias and higher consistency of DVR estimates than of SUVR. The RE plot and the bcSUVR are practical quantitative approaches that improve the analysis of (11)C-PiB studies.

  16. Quantitative evaluation of fatty degeneration of the supraspinatus and infraspinatus muscles using T2 mapping.

    PubMed

    Matsuki, Keisuke; Watanabe, Atsuya; Ochiai, Shunsuke; Kenmoku, Tomonori; Ochiai, Nobuyasu; Obata, Takayuki; Toyone, Tomoaki; Wada, Yuichi; Okubo, Toshiyuki

    2014-05-01

    Although fatty degeneration of the rotator cuff muscles has been reported to affect the outcomes of rotator cuff repairs, only a few studies have attempted to quantitatively evaluate this degeneration. T2 mapping is a quantitative magnetic resonance imaging technique that potentially evaluates the concentration of fat in muscles. The purpose of this study was to investigate fatty degeneration of the rotator cuff muscles by using T2 mapping, as well as to evaluate the reliability of T2 measurement. We obtained magnetic resonance images including T2 mapping from 184 shoulders (180 patients; 110 male patients [112 shoulders] and 70 female patients [72 shoulders]; mean age, 62 years [range, 16-84 years]). Eighty-three shoulders had no rotator cuff tear (group A), whereas 101 shoulders had tears, of which 62 were incomplete to medium (group B) and 39 were large to massive (group C). T2 values of the supraspinatus and infraspinatus muscles were measured and compared among groups. Intraobserver and interobserver variabilities also were examined. The mean T2 values of the supraspinatus in groups A, B, and C were 36.3 ± 4.7 milliseconds, 44.2 ± 11.3 milliseconds, and 57.0 ± 18.8 milliseconds, respectively. The mean T2 values of the infraspinatus in groups A, B, and C were 36.1 ± 5.1 milliseconds, 40.0 ± 11.1 milliseconds, and 51.9 ± 18.2 milliseconds, respectively. The T2 value significantly increased with the extent of the tear in both muscles. Both intraobserver and interobserver variabilities were more than 0.99. T2 mapping can be a reliable tool to quantify fatty degeneration of the rotator cuff muscles. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  17. Quantitative determination of band distortions in diamond attenuated total reflectance infrared spectra.

    PubMed

    Boulet-Audet, Maxime; Buffeteau, Thierry; Boudreault, Simon; Daugey, Nicolas; Pézolet, Michel

    2010-06-24

    Due to its unmatched hardness and chemical inertia, diamond offers many advantages over other materials for extreme conditions and routine analysis by attenuated total reflection (ATR) infrared spectroscopy. Its low refractive index can offer up to a 6-fold absorbance increase compared to germanium. Unfortunately, it also results for strong bands in spectral distortions compared to transmission experiments. The aim of this paper is to present a methodological approach to determine quantitatively the degree of the spectral distortions in ATR spectra. This approach requires the determination of the optical constants (refractive index and extinction coefficient) of the investigated sample. As a typical example, the optical constants of the fibroin protein of the silk worm Bombyx mori have been determined from the polarized ATR spectra obtained using both diamond and germanium internal reflection elements. The positions found for the amide I band by germanium and diamond ATR are respectively 6 and 17 cm(-1) lower than the true value dtermined from the k(nu) spectrum, which is calculated to be 1659 cm(-1). To determine quantitatively the effect of relevant parameters such as the film thickness and the protein concentration, various spectral simulations have also been performed. The use of a thinner film probed by light polarized in the plane of incidence and diluting the protein sample can help in obtaining ATR spectra that are closer to their transmittance counterparts. To extend this study to any system, the ATR distortion amplitude has been evaluated using spectral simulations performed for bands of various intensities and widths. From these simulations, a simple empirical relationship has been found to estimate the band shift from the experimental band height and width that could be of practical use for ATR users. This paper shows that the determination of optical constants provides an efficient way to recover the true spectrum shape and band frequencies of

  18. Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, Jay P.; Lei, Xiudong; Huang, Sheng-Cheng

    Purpose: To measure, by quantitative analysis of digital photographs, breast cosmetic outcome within the setting of a randomized trial of conventionally fractionated (CF) and hypofractionated (HF) whole-breast irradiation (WBI), to identify how quantitative cosmesis metrics were associated with patient- and physician-reported cosmesis and whether they differed by treatment arm. Methods and Materials: From 2011 to 2014, 287 women aged ≥40 with ductal carcinoma in situ or early invasive breast cancer were randomized to HF-WBI (42.56 Gy/16 fractions [fx] + 10-12.5 Gy/4-5 fx boost) or CF-WBI (50 Gy/25 fx + 10-14 Gy/5-7 fx). At 1 year after treatment we collected digital photographs, patient-reported cosmesis using the Breast Cancer Treatment and Outcomesmore » Scale, and physician-reported cosmesis using the Radiation Therapy Oncology Group scale. Six quantitative measures of breast symmetry, labeled M1-M6, were calculated from anteroposterior digital photographs. For each measure, values closer to 1 imply greater symmetry, and values closer to 0 imply greater asymmetry. Associations between M1-M6 and patient- and physician-reported cosmesis and treatment arm were evaluated using the Kruskal-Wallis test. Results: Among 245 evaluable patients, patient-reported cosmesis was strongly associated with M1 (vertical symmetry measure) (P<.01). Physician-reported cosmesis was similarly correlated with M1 (P<.01) and also with M2 (vertical symmetry, P=.01) and M4 (horizontal symmetry, P=.03). At 1 year after treatment, HF-WBI resulted in better values of M2 (P=.02) and M3 (P<.01) than CF-WBI; treatment arm was not significantly associated with M1, M4, M5, or M6 (P≥.12). Conclusions: Quantitative assessment of breast photographs reveals similar to improved cosmetic outcome with HF-WBI compared with CF-WBI 1 year after treatment. Assessing cosmetic outcome using these measures could be useful for future comparative effectiveness studies and outcome reporting.« less

  19. Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation.

    PubMed

    Reddy, Jay P; Lei, Xiudong; Huang, Sheng-Cheng; Nicklaus, Krista M; Fingeret, Michelle C; Shaitelman, Simona F; Hunt, Kelly K; Buchholz, Thomas A; Merchant, Fatima; Markey, Mia K; Smith, Benjamin D

    2017-04-01

    To measure, by quantitative analysis of digital photographs, breast cosmetic outcome within the setting of a randomized trial of conventionally fractionated (CF) and hypofractionated (HF) whole-breast irradiation (WBI), to identify how quantitative cosmesis metrics were associated with patient- and physician-reported cosmesis and whether they differed by treatment arm. From 2011 to 2014, 287 women aged ≥40 with ductal carcinoma in situ or early invasive breast cancer were randomized to HF-WBI (42.56 Gy/16 fractions [fx] + 10-12.5 Gy/4-5 fx boost) or CF-WBI (50 Gy/25 fx + 10-14 Gy/5-7 fx). At 1 year after treatment we collected digital photographs, patient-reported cosmesis using the Breast Cancer Treatment and Outcomes Scale, and physician-reported cosmesis using the Radiation Therapy Oncology Group scale. Six quantitative measures of breast symmetry, labeled M1-M6, were calculated from anteroposterior digital photographs. For each measure, values closer to 1 imply greater symmetry, and values closer to 0 imply greater asymmetry. Associations between M1-M6 and patient- and physician-reported cosmesis and treatment arm were evaluated using the Kruskal-Wallis test. Among 245 evaluable patients, patient-reported cosmesis was strongly associated with M1 (vertical symmetry measure) (P<.01). Physician-reported cosmesis was similarly correlated with M1 (P<.01) and also with M2 (vertical symmetry, P=.01) and M4 (horizontal symmetry, P=.03). At 1 year after treatment, HF-WBI resulted in better values of M2 (P=.02) and M3 (P<.01) than CF-WBI; treatment arm was not significantly associated with M1, M4, M5, or M6 (P≥.12). Quantitative assessment of breast photographs reveals similar to improved cosmetic outcome with HF-WBI compared with CF-WBI 1 year after treatment. Assessing cosmetic outcome using these measures could be useful for future comparative effectiveness studies and outcome reporting. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Perceived Value of University-Based Continuing Education Leadership Development Programs for Administrators

    ERIC Educational Resources Information Center

    Stone, Geri L.; Major, Claire H.

    2014-01-01

    This quantitative study, which involved development of a Value Creation Survey, examined the perceived value of leadership development programs (LDPs) provided by continuing higher education for administrators in colleges and universities. Participants were administrators at Association for Continuing Higher Education (ACHE) member institutions.…

  1. Multivariate reference technique for quantitative analysis of fiber-optic tissue Raman spectroscopy.

    PubMed

    Bergholt, Mads Sylvest; Duraipandian, Shiyamala; Zheng, Wei; Huang, Zhiwei

    2013-12-03

    We report a novel method making use of multivariate reference signals of fused silica and sapphire Raman signals generated from a ball-lens fiber-optic Raman probe for quantitative analysis of in vivo tissue Raman measurements in real time. Partial least-squares (PLS) regression modeling is applied to extract the characteristic internal reference Raman signals (e.g., shoulder of the prominent fused silica boson peak (~130 cm(-1)); distinct sapphire ball-lens peaks (380, 417, 646, and 751 cm(-1))) from the ball-lens fiber-optic Raman probe for quantitative analysis of fiber-optic Raman spectroscopy. To evaluate the analytical value of this novel multivariate reference technique, a rapid Raman spectroscopy system coupled with a ball-lens fiber-optic Raman probe is used for in vivo oral tissue Raman measurements (n = 25 subjects) under 785 nm laser excitation powers ranging from 5 to 65 mW. An accurate linear relationship (R(2) = 0.981) with a root-mean-square error of cross validation (RMSECV) of 2.5 mW can be obtained for predicting the laser excitation power changes based on a leave-one-subject-out cross-validation, which is superior to the normal univariate reference method (RMSE = 6.2 mW). A root-mean-square error of prediction (RMSEP) of 2.4 mW (R(2) = 0.985) can also be achieved for laser power prediction in real time when we applied the multivariate method independently on the five new subjects (n = 166 spectra). We further apply the multivariate reference technique for quantitative analysis of gelatin tissue phantoms that gives rise to an RMSEP of ~2.0% (R(2) = 0.998) independent of laser excitation power variations. This work demonstrates that multivariate reference technique can be advantageously used to monitor and correct the variations of laser excitation power and fiber coupling efficiency in situ for standardizing the tissue Raman intensity to realize quantitative analysis of tissue Raman measurements in vivo, which is particularly appealing in

  2. How to quantitatively evaluate safety of driver behavior upon accident? A biomechanical methodology

    PubMed Central

    Zhang, Wen; Cao, Jieer

    2017-01-01

    How to evaluate driver spontaneous reactions in various collision patterns in a quantitative way is one of the most important topics in vehicle safety. Firstly, this paper constructs representative numerical crash scenarios described by impact velocity, impact angle and contact position based on finite element (FE) computation platform. Secondly, a driver cabin model is extracted and described in the well validated multi-rigid body (MB) model to compute the value of weighted injury criterion to quantitatively assess drivers’ overall injury under certain circumstances. Furthermore, based on the coupling of FE and MB, parametric studies on various crash scenarios are conducted. It is revealed that the WIC (Weighted Injury Criteria) value variation law under high impact velocities is quite distinct comparing with the one in low impact velocities. In addition, the coupling effect can be elucidated by the fact that the difference of WIC value among three impact velocities under smaller impact angles tends to be distinctly higher than that under larger impact angles. Meanwhile, high impact velocity also increases the sensitivity of WIC under different collision positions and impact angles. Results may provide a new methodology to quantitatively evaluate driving behaviors and serve as a significant guiding step towards collision avoidance for autonomous driving vehicles. PMID:29240789

  3. How to quantitatively evaluate safety of driver behavior upon accident? A biomechanical methodology.

    PubMed

    Zhang, Wen; Cao, Jieer; Xu, Jun

    2017-01-01

    How to evaluate driver spontaneous reactions in various collision patterns in a quantitative way is one of the most important topics in vehicle safety. Firstly, this paper constructs representative numerical crash scenarios described by impact velocity, impact angle and contact position based on finite element (FE) computation platform. Secondly, a driver cabin model is extracted and described in the well validated multi-rigid body (MB) model to compute the value of weighted injury criterion to quantitatively assess drivers' overall injury under certain circumstances. Furthermore, based on the coupling of FE and MB, parametric studies on various crash scenarios are conducted. It is revealed that the WIC (Weighted Injury Criteria) value variation law under high impact velocities is quite distinct comparing with the one in low impact velocities. In addition, the coupling effect can be elucidated by the fact that the difference of WIC value among three impact velocities under smaller impact angles tends to be distinctly higher than that under larger impact angles. Meanwhile, high impact velocity also increases the sensitivity of WIC under different collision positions and impact angles. Results may provide a new methodology to quantitatively evaluate driving behaviors and serve as a significant guiding step towards collision avoidance for autonomous driving vehicles.

  4. Quantitative SIMS Imaging of Agar-Based Microbial Communities.

    PubMed

    Dunham, Sage J B; Ellis, Joseph F; Baig, Nameera F; Morales-Soto, Nydia; Cao, Tianyuan; Shrout, Joshua D; Bohn, Paul W; Sweedler, Jonathan V

    2018-05-01

    After several decades of widespread use for mapping elemental ions and small molecular fragments in surface science, secondary ion mass spectrometry (SIMS) has emerged as a powerful analytical tool for molecular imaging in biology. Biomolecular SIMS imaging has primarily been used as a qualitative technique; although the distribution of a single analyte can be accurately determined, it is difficult to map the absolute quantity of a compound or even to compare the relative abundance of one molecular species to that of another. We describe a method for quantitative SIMS imaging of small molecules in agar-based microbial communities. The microbes are cultivated on a thin film of agar, dried under nitrogen, and imaged directly with SIMS. By use of optical microscopy, we show that the area of the agar is reduced by 26 ± 2% (standard deviation) during dehydration, but the overall biofilm morphology and analyte distribution are largely retained. We detail a quantitative imaging methodology, in which the ion intensity of each analyte is (1) normalized to an external quadratic regression curve, (2) corrected for isomeric interference, and (3) filtered for sample-specific noise and lower and upper limits of quantitation. The end result is a two-dimensional surface density image for each analyte. The sample preparation and quantitation methods are validated by quantitatively imaging four alkyl-quinolone and alkyl-quinoline N-oxide signaling molecules (including Pseudomonas quinolone signal) in Pseudomonas aeruginosa colony biofilms. We show that the relative surface densities of the target biomolecules are substantially different from values inferred through direct intensity comparison and that the developed methodologies can be used to quantitatively compare as many ions as there are available standards.

  5. Qualitative pattern classification of shear wave elastography for breast masses: how it correlates to quantitative measurements.

    PubMed

    Yoon, Jung Hyun; Ko, Kyung Hee; Jung, Hae Kyoung; Lee, Jong Tae

    2013-12-01

    To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21-88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P<0.001). Sensitivity was significantly decreased in US combined to SWE measurements to grayscale US: 69.5-89.8% to 100.0%, while specificity was significantly improved: 62.5-81.7% to 13.9% (P<0.001). Area under the ROC curve (Az) did not show significant differences between grayscale US to US combined to SWE (P>0.05). Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Evaluation of New Quantitative Assays for Diagnosis and Monitoring of Cytomegalovirus Disease in Human Immunodeficiency Virus-Positive Patients

    PubMed Central

    Pellegrin, Isabelle; Garrigue, Isabelle; Binquet, Christine; Chene, Genevieve; Neau, Didier; Bonot, Pascal; Bonnet, Fabrice; Fleury, Herve; Pellegrin, Jean-Luc

    1999-01-01

    Cobas Amplicor CMV Monitor (CMM) and Quantiplex CMV bDNA 2.0 (CMV bDNA 2.0), two new standardized and quantitative assays for the detection of cytomegalovirus (CMV) DNA in plasma and peripheral blood leukocytes (PBLs), respectively, were compared to the CMV viremia assay, pp65 antigenemia assay, and the Amplicor CMV test (P-AMP). The CMV loads were measured in 384 samples from 58 human immunodeficiency virus (HIV) type 1-infected, CMV-seropositive subjects, including 13 with symptomatic CMV disease. The assays were highly concordant (agreement, 0.88 to 0.97) except when the CMV load was low. Quantitative results for plasma and PBLs were significantly correlated (Spearman ρ = 0.92). For PBLs, positive results were obtained 125 days before symptomatic CMV disease by CMV bDNA 2.0 and 124 days by pp65 antigenemia assay, whereas they were obtained 46 days before symptomatic CMV disease by CMM and P-AMP. At the time of CMV disease diagnosis, the sensitivity, specificity, and positive and negative predictive values of CMV bDNA 2.0 were 92.3, 97.8, 92.3, and 97.8%, respectively, whereas they were 92.3, 93.3, 80, and 97.8%, respectively, for the pp65 antigenemia assay; 84.6, 100, 100, and 95.7%, respectively, for CMM; and 76.9, 100, 100, and 93.8%, respectively, for P-AMP. Considering the entire follow-up, the sensitivity, specificity, and positive and negative predictive values of CMV bDNA 2.0 were 92.3, 73.3, 52.1, and 97.1%, respectively, whereas they were 100, 55.5, 39.4, and 100%, respectively, for the pp65 antigenemia assay; 92.3, 86.7, 66.7, and 97.5%, respectively, for CMM; and 84.6, 91.1, 73.3, and 95.3%, respectively, for P-AMP. Detection of CMV in plasma is technically easy and, despite its later positivity (i.e., later than in PBLs), can provide enough information sufficiently early so that HIV-infected patients can be effectively treated. In addition, these standardized quantitative assays accurately monitor the efficacy of anti-CMV treatment. PMID:10488165

  7. Differentiation of malignant and benign breast lesions: Added value of the qualitative analysis of breast lesions on diffusion-weighted imaging (DWI) using readout-segmented echo-planar imaging at 3.0 T.

    PubMed

    An, Yeong Yi; Kim, Sung Hun; Kang, Bong Joo

    2017-01-01

    To determine the added value of qualitative analysis as an adjunct to quantitative analysis for the discrimination of benign and malignant lesions in patients with breast cancer using diffusion-weighted imaging (DWI) with readout-segmented echo-planar imaging (rs-EPI). A total of 99 patients with 144 lesions were reviewed from our prospectively collected database. DWI data were obtained using rs-EPI acquired at 3.0 T. The diagnostic performances of DWI in the qualitative, quantitative, and combination analyses were compared with that of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Additionally, the effect of lesion size on the diagnostic performance of the DWI combination analysis was evaluated. The strongest indicators of malignancy on DWI were a heterogeneous pattern (P = 0.005) and an apparent diffusion coefficient (ADC) value <1.0 × 10-3 mm2/sec (P = 0.002). The area under the curve (AUC) values for the qualitative analysis, quantitative analysis, and combination analysis on DWI were 0.732 (95% CI, 0.651-0.803), 0.780 (95% CI, 0.703-0.846), and 0.826 (95% CI, 0.754-0.885), respectively (P<0.0001). The AUC for the combination analysis on DWI was superior to that for DCE-MRI alone (0.651, P = 0.003) but inferior to that for DCE-MRI plus the ADC value (0.883, P = 0.03). For the DWI combination analysis, the sensitivity was significantly lower in the size ≤1 cm group than in the size >1 cm group (80% vs. 95.6%, P = 0.034). Qualitative analysis of tumor morphology was diagnostically applicable on DWI using rs-EPI. This qualitative analysis adds value to quantitative analyses for lesion characterization in patients with breast cancer.

  8. Quantitative landslide risk assessment and mapping on the basis of recent occurrences

    NASA Astrophysics Data System (ADS)

    Remondo, Juan; Bonachea, Jaime; Cendrero, Antonio

    A quantitative procedure for mapping landslide risk is developed from considerations of hazard, vulnerability and valuation of exposed elements. The approach based on former work by the authors, is applied in the Bajo Deba area (northern Spain) where a detailed study of landslide occurrence and damage in the recent past (last 50 years) was carried out. Analyses and mapping are implemented in a Geographic Information System (GIS). The method is based on a susceptibility model developed previously from statistical relationships between past landslides and terrain parameters related to instability. Extrapolations based on past landslide behaviour were used to calculate failure frequency for the next 50 years. A detailed inventory of direct damage due to landslides during the study period was carried out and the main elements at risk in the area identified and mapped. Past direct (monetary) losses per type of element were estimated and expressed as an average 'specific loss' for events of a given magnitude (corresponding to a specified scenario). Vulnerability was assessed by comparing losses with the actual value of the elements affected and expressed as a fraction of that value (0-1). From hazard, vulnerability and monetary value, risk was computed for each element considered. Direct risk maps (€/pixel/year) were obtained and indirect losses from the disruption of economic activities due to landslides assessed. The final result is a risk map and table combining all losses per pixel for a 50-year period. Total monetary value at risk for the Bajo Deba area in the next 50 years is about 2.4 × 10 6 Euros.

  9. Quantitative Evaluation of Performance during Robot-assisted Treatment.

    PubMed

    Peri, E; Biffi, E; Maghini, C; Servodio Iammarrone, F; Gagliardi, C; Germiniasi, C; Pedrocchi, A; Turconi, A C; Reni, G

    2016-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Methodologies, Models and Algorithms for Patients Rehabilitation". The great potential of robots in extracting quantitative and meaningful data is not always exploited in clinical practice. The aim of the present work is to describe a simple parameter to assess the performance of subjects during upper limb robotic training exploiting data automatically recorded by the robot, with no additional effort for patients and clinicians. Fourteen children affected by cerebral palsy (CP) performed a training with Armeo®Spring. Each session was evaluated with P, a simple parameter that depends on the overall performance recorded, and median and interquartile values were computed to perform a group analysis. Median (interquartile) values of P significantly increased from 0.27 (0.21) at T0 to 0.55 (0.27) at T1 . This improvement was functionally validated by a significant increase of the Melbourne Assessment of Unilateral Upper Limb Function. The parameter described here was able to show variations in performance over time and enabled a quantitative evaluation of motion abilities in a way that is reliable with respect to a well-known clinical scale.

  10. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): A Transversal, descriptive, and comparative study

    PubMed Central

    2010-01-01

    Background To assess the reliability of the measurements obtained with the PalmScan™, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Methods Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan™ A2000 and Eye Cubed™) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. Results 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed™ of AL and ACD were shorter than the measurements taken by the PalmScan™. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan™ measurements were shorter, but not statistically significantly (p < 0.2). Conclusions The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon. PMID:20334670

  11. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): a transversal, descriptive, and comparative study.

    PubMed

    Velez-Montoya, Raul; Shusterman, Eugene Mark; López-Miranda, Miriam Jessica; Mayorquin-Ruiz, Mariana; Salcedo-Villanueva, Guillermo; Quiroz-Mercado, Hugo; Morales-Cantón, Virgilio

    2010-03-24

    To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed of AL and ACD were shorter than the measurements taken by the PalmScan. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan measurements were shorter, but not statistically significantly (p < 0.2). The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon.

  12. Comparison of biochemical values in serum and plasma, fresh and frozen plasma, and hemolyzed samples from orange-winged Amazon parrots (Amazona amazonica).

    PubMed

    Hawkins, Michelle G; Kass, Philip H; Zinkl, Joseph G; Tell, Lisa A

    2006-06-01

    To the authors' knowledge, on the basis of sample type, storage condition, or hemolysis, differences in serum and plasma biochemical values have not been evaluated in orange-winged Amazon parrots (Amazona amazonica). The purpose of this study was to compare values for biochemical analytes in serum vs plasma, fresh vs frozen plasma, and nonhemolyzed vs hemolyzed samples in orange-winged Amazon parrots. We also compared differences in serum and plasma yield from whole-blood aliquots. Fifteen biochemical analytes were evaluated in paired serum and plasma, fresh and frozen plasma, nonhemolyzed and hemolyzed serum and plasma samples from orange-winged Amazon parrots (n = 10) using a wet reagent analyzer. Hemolysis was assessed qualitatively (visually) and quantitatively (hemoglobin [Hgb] measured spectrophotometrically). Serum and plasma yields from 500-microl whole-blood aliquots were determined from centrifuged samples. Analyte values significantly differed among sample groups, but were still within published reference intervals, with the exception of increases in potassium concentration in markedly hemolyzed serum and plasma samples. Clinically important changes in hemolyzed serum and plasma samples included increases in potassium, phosphorus, and albumin concentrations and lactate dehydrogenase activity. The degree of hemolysis assigned qualitatively did not correlate with quantitative Hgb concentration. A significantly greater yield of plasma (288 +/- 13 microL) than serum (241 +/- 44 microL) was obtained. Significant differences may occur in different sample types, however, only changes in potassium, phosphorus, albumin, and lactate dehydrogenase values in hemolyzed samples were considered clinically relevant. Lack of agreement between qualitative and quantitative Hgb concentration indicates the unreliability of visual estimation. Based on higher sample yield, and lack of clinically relevant differences from serum, plasma is a better sample choice for clinical

  13. Hematocrit Measurement with R2* and Quantitative Susceptibility Mapping in Postmortem Brain.

    PubMed

    Walsh, A J; Sun, H; Emery, D J; Wilman, A H

    2018-05-24

    Noninvasive venous oxygenation quantification with MR imaging will improve the neurophysiologic investigation and the understanding of the pathophysiology in neurologic diseases. Available MR imaging methods are limited by sensitivity to flow and often require assumptions of the hematocrit level. In situ postmortem imaging enables evaluation of methods in a fully deoxygenated environment without flow artifacts, allowing direct calculation of hematocrit. This study compares 2 venous oxygenation quantification methods in in situ postmortem subjects. Transverse relaxation (R2*) mapping and quantitative susceptibility mapping were performed on a whole-body 4.7T MR imaging system. Intravenous measurements in major draining intracranial veins were compared between the 2 methods in 3 postmortem subjects. The quantitative susceptibility mapping technique was also applied in 10 healthy control subjects and compared with reference venous oxygenation values. In 2 early postmortem subjects, R2* mapping and quantitative susceptibility mapping measurements within intracranial veins had a significant and strong correlation ( R 2 = 0.805, P = .004 and R 2 = 0.836, P = .02). Higher R2* and susceptibility values were consistently demonstrated within gravitationally dependent venous segments during the early postmortem period. Hematocrit ranged from 0.102 to 0.580 in postmortem subjects, with R2* and susceptibility as large as 291 seconds -1 and 1.75 ppm, respectively. Measurements of R2* and quantitative susceptibility mapping within large intracranial draining veins have a high correlation in early postmortem subjects. This study supports the use of quantitative susceptibility mapping for evaluation of in vivo venous oxygenation and postmortem hematocrit concentrations. © 2018 by American Journal of Neuroradiology.

  14. Comparison with IRI-PLUS and IRI-2012-TEC values of GPS-TEC values

    NASA Astrophysics Data System (ADS)

    Atıcı, Ramazan; Saǧır, Selçuk

    2016-07-01

    This study presents a comparison with IRI-PLUS and IRI-2012 Total Electron Content (TEC) values of Total Electron Content (TEC) values obtained from Ankara station (39,7 N; 32,76 E) of Global Position System (GPS) of Turkey on equinox and solstice days of 2009 year. For all days, it is observed that GPS-TEC values are greater than IRI-2012-TEC values, while IRI-PLUS-TEC values are very close to GPS-TEC values. When GPS-TEC values for both equinoxes are compared, it is seen that TEC values on September equinox are greater than one on March equinox. However, it is observed that GPS-TEC values on June solstice are greater than one on December solstice. Also, the relationship between GPS-TEC values and geomagnetic indexes is investigated.

  15. A Quantitative Comparison of Leading-edge Vortices in Incompressible and Supersonic Flows

    NASA Technical Reports Server (NTRS)

    Wang, F. Y.; Milanovic, I. M.; Zaman, K. B. M. Q.

    2002-01-01

    When requiring quantitative data on delta-wing vortices for design purposes, low-speed results have often been extrapolated to configurations intended for supersonic operation. This practice stems from a lack of database owing to difficulties that plague measurement techniques in high-speed flows. In the present paper an attempt is made to examine this practice by comparing quantitative data on the nearwake properties of such vortices in incompressible and supersonic flows. The incompressible flow data are obtained in experiments conducted in a low-speed wind tunnel. Detailed flow-field properties, including vorticity and turbulence characteristics, obtained by hot-wire and pressure probe surveys are documented. These data are compared, wherever possible, with available data from a past work for a Mach 2.49 flow for the same wing geometry and angles-of-attack. The results indicate that quantitative similarities exist in the distributions of total pressure and swirl velocity. However, the streamwise velocity of the core exhibits different trends. The axial flow characteristics of the vortices in the two regimes are examined, and a candidate theory is discussed.

  16. Quantitative Surface Chirality Detection with Sum Frequency Generation Vibrational Spectroscopy: Twin Polarization Angle Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wei, Feng; Xu, Yanyan; Guo, Yuan

    2009-12-27

    Here we report a novel twin polarization angle (TPA) approach in the quantitative chirality detection with the surface sum-frequency generation vibrational spectroscopy (SFG-VS). Generally, the achiral contribution dominates the surface SFG-VS signal, and the pure chiral signal is usually two or three orders of magnitude smaller. Therefore, it has been difficult to make quantitative detection and analysis of the chiral contributions to the surface SFG- VS signal. In the TPA method, by varying together the polarization angles of the incoming visible light and the sum frequency signal at fixed s or p polarization of the incoming infrared beam, the polarizationmore » dependent SFG signal can give not only direct signature of the chiral contribution in the total SFG-VS signal, but also the accurate measurement of the chiral and achiral components in the surface SFG signal. The general description of the TPA method is presented and the experiment test of the TPA approach is also presented for the SFG-VS from the S- and R-limonene chiral liquid surfaces. The most accurate degree of chiral excess values thus obtained for the 2878 cm⁻¹ spectral peak of the S- and R-limonene liquid surfaces are (23.7±0.4)% and ({25.4±1.3)%, respectively.« less

  17. A practical guide to value of information analysis.

    PubMed

    Wilson, Edward C F

    2015-02-01

    Value of information analysis is a quantitative method to estimate the return on investment in proposed research projects. It can be used in a number of ways. Funders of research may find it useful to rank projects in terms of the expected return on investment from a variety of competing projects. Alternatively, trialists can use the principles to identify the efficient sample size of a proposed study as an alternative to traditional power calculations, and finally, a value of information analysis can be conducted alongside an economic evaluation as a quantitative adjunct to the 'future research' or 'next steps' section of a study write up. The purpose of this paper is to present a brief introduction to the methods, a step-by-step guide to calculation and a discussion of issues that arise in their application to healthcare decision making. Worked examples are provided in the accompanying online appendices as Microsoft Excel spreadsheets.

  18. Cleavage Entropy as Quantitative Measure of Protease Specificity

    PubMed Central

    Fuchs, Julian E.; von Grafenstein, Susanne; Huber, Roland G.; Margreiter, Michael A.; Spitzer, Gudrun M.; Wallnoefer, Hannes G.; Liedl, Klaus R.

    2013-01-01

    A purely information theory-guided approach to quantitatively characterize protease specificity is established. We calculate an entropy value for each protease subpocket based on sequences of cleaved substrates extracted from the MEROPS database. We compare our results with known subpocket specificity profiles for individual proteases and protease groups (e.g. serine proteases, metallo proteases) and reflect them quantitatively. Summation of subpocket-wise cleavage entropy contributions yields a measure for overall protease substrate specificity. This total cleavage entropy allows ranking of different proteases with respect to their specificity, separating unspecific digestive enzymes showing high total cleavage entropy from specific proteases involved in signaling cascades. The development of a quantitative cleavage entropy score allows an unbiased comparison of subpocket-wise and overall protease specificity. Thus, it enables assessment of relative importance of physicochemical and structural descriptors in protease recognition. We present an exemplary application of cleavage entropy in tracing substrate specificity in protease evolution. This highlights the wide range of substrate promiscuity within homologue proteases and hence the heavy impact of a limited number of mutations on individual substrate specificity. PMID:23637583

  19. Quantitative methods in electroencephalography to access therapeutic response.

    PubMed

    Diniz, Roseane Costa; Fontenele, Andrea Martins Melo; Carmo, Luiza Helena Araújo do; Ribeiro, Aurea Celeste da Costa; Sales, Fábio Henrique Silva; Monteiro, Sally Cristina Moutinho; Sousa, Ana Karoline Ferreira de Castro

    2016-07-01

    Pharmacometrics or Quantitative Pharmacology aims to quantitatively analyze the interaction between drugs and patients whose tripod: pharmacokinetics, pharmacodynamics and disease monitoring to identify variability in drug response. Being the subject of central interest in the training of pharmacists, this work was out with a view to promoting this idea on methods to access the therapeutic response of drugs with central action. This paper discusses quantitative methods (Fast Fourier Transform, Magnitude Square Coherence, Conditional Entropy, Generalised Linear semi-canonical Correlation Analysis, Statistical Parametric Network and Mutual Information Function) used to evaluate the EEG signals obtained after administration regimen of drugs, the main findings and their clinical relevance, pointing it as a contribution to construction of different pharmaceutical practice. Peter Anderer et. al in 2000 showed the effect of 20mg of buspirone in 20 healthy subjects after 1, 2, 4, 6 and 8h after oral ingestion of the drug. The areas of increased power of the theta frequency occurred mainly in the temporo-occipital - parietal region. It has been shown by Sampaio et al., 2007 that the use of bromazepam, which allows the release of GABA (gamma amino butyric acid), an inhibitory neurotransmitter of the central nervous system could theoretically promote dissociation of cortical functional areas, a decrease of functional connectivity, a decrease of cognitive functions by means of smaller coherence (electrophysiological magnitude measured from the EEG by software) values. Ahmad Khodayari-Rostamabad et al. in 2015 talk that such a measure could be a useful clinical tool potentially to assess adverse effects of opioids and hence give rise to treatment guidelines. There was the relation between changes in pain intensity and brain sources (at maximum activity locations) during remifentanil infusion despite its potent analgesic effect. The statement of mathematical and computational

  20. Supply chain risk management of newspaper industry: A quantitative study

    NASA Astrophysics Data System (ADS)

    Sartika, Viny; Hisjam, Muh.; Sutopo, Wahyudi

    2018-02-01

    The newspaper industry has several distinctive features that make it stands out from other industries. The strict delivery deadline and zero inventory led to a very short time frame for production and distribution. On the other hand, there is pressure from the newsroom to encourage the start of production as slowly as possible in order to enter the news, while there is pressure from production and distribution to start production as early as possible. Supply chain risk management is needed in determining the best strategy for dealing with possible risks in the newspaper industry. In a case study of a newspaper in Surakarta, quantitative approaches are made to the newspaper supply chain risk management by calculating the expected cost of risk based on the magnitude of the impact and the probability of a risk event. From the calculation results obtained that the five risks with the highest value are newspaper delays to the end customer, broken plate, miss print, down machine, and delayed delivery of newspaper content. Then analyzed appropriate mitigation strategies to cope with such risk events.

  1. Finite-volume application of high order ENO schemes to multi-dimensional boundary-value problems

    NASA Technical Reports Server (NTRS)

    Casper, Jay; Dorrepaal, J. Mark

    1990-01-01

    The finite volume approach in developing multi-dimensional, high-order accurate essentially non-oscillatory (ENO) schemes is considered. In particular, a two dimensional extension is proposed for the Euler equation of gas dynamics. This requires a spatial reconstruction operator that attains formal high order of accuracy in two dimensions by taking account of cross gradients. Given a set of cell averages in two spatial variables, polynomial interpolation of a two dimensional primitive function is employed in order to extract high-order pointwise values on cell interfaces. These points are appropriately chosen so that correspondingly high-order flux integrals are obtained through each interface by quadrature, at each point having calculated a flux contribution in an upwind fashion. The solution-in-the-small of Riemann's initial value problem (IVP) that is required for this pointwise flux computation is achieved using Roe's approximate Riemann solver. Issues to be considered in this two dimensional extension include the implementation of boundary conditions and application to general curvilinear coordinates. Results of numerical experiments are presented for qualitative and quantitative examination. These results contain the first successful application of ENO schemes to boundary value problems with solid walls.

  2. Quantitative structure-activation barrier relationship modeling for Diels-Alder ligations utilizing quantum chemical structural descriptors.

    PubMed

    Nandi, Sisir; Monesi, Alessandro; Drgan, Viktor; Merzel, Franci; Novič, Marjana

    2013-10-30

    In the present study, we show the correlation of quantum chemical structural descriptors with the activation barriers of the Diels-Alder ligations. A set of 72 non-catalysed Diels-Alder reactions were subjected to quantitative structure-activation barrier relationship (QSABR) under the framework of theoretical quantum chemical descriptors calculated solely from the structures of diene and dienophile reactants. Experimental activation barrier data were obtained from literature. Descriptors were computed using Hartree-Fock theory using 6-31G(d) basis set as implemented in Gaussian 09 software. Variable selection and model development were carried out by stepwise multiple linear regression methodology. Predictive performance of the quantitative structure-activation barrier relationship (QSABR) model was assessed by training and test set concept and by calculating leave-one-out cross-validated Q2 and predictive R2 values. The QSABR model can explain and predict 86.5% and 80% of the variances, respectively, in the activation energy barrier training data. Alternatively, a neural network model based on back propagation of errors was developed to assess the nonlinearity of the sought correlations between theoretical descriptors and experimental reaction barriers. A reasonable predictability for the activation barrier of the test set reactions was obtained, which enabled an exploration and interpretation of the significant variables responsible for Diels-Alder interaction between dienes and dienophiles. Thus, studies in the direction of QSABR modelling that provide efficient and fast prediction of activation barriers of the Diels-Alder reactions turn out to be a meaningful alternative to transition state theory based computation.

  3. Geographic and demographic variabilities of quantitative parameters in stress myocardial computed tomography perfusion.

    PubMed

    Park, Jinoh; Kim, Hyun-Sook; Hwang, Hye Jeon; Yang, Dong Hyun; Koo, Hyun Jung; Kang, Joon-Won; Kim, Young-Hak

    2017-09-01

    To evaluate the geographic and demographic variabilities of the quantitative parameters of computed tomography perfusion (CTP) of the left ventricular (LV) myocardium in patients with normal coronary artery on computed tomography angiography (CTA). From a multicenter CTP registry of stress and static computed tomography, we retrospectively recruited 113 patients (mean age, 60 years; 57 men) without perfusion defect on visual assessment and minimal (< 20% of diameter stenosis) or no coronary artery disease on CTA. Using semiautomatic analysis software, quantitative parameters of the LV myocardium, including the myocardial attenuation in stress and rest phases, transmural perfusion ratio (TPR), and myocardial perfusion reserve index (MPRI), were evaluated in 16 myocardial segments. In the lateral wall of the LV myocardium, all quantitative parameters except for MPRI were significantly higher compared with those in the other walls. The MPRI showed consistent values in all myocardial walls (anterior to lateral wall: range, 25% to 27%; p = 0.401). At the basal level of the myocardium, all quantitative parameters were significantly lower than those at the mid- and apical levels. Compared with men, women had significantly higher values of myocardial attenuation and TPR. Age, body mass index, and Framingham risk score were significantly associated with the difference in myocardial attenuation. Geographic and demographic variabilities of quantitative parameters in stress myocardial CTP exist in healthy subjects without significant coronary artery disease. This information may be helpful when assessing myocardial perfusion defects in CTP.

  4. Visual and Quantitative Analysis Methods of Respiratory Patterns for Respiratory Gated PET/CT.

    PubMed

    Son, Hye Joo; Jeong, Young Jin; Yoon, Hyun Jin; Park, Jong-Hwan; Kang, Do-Young

    2016-01-01

    We integrated visual and quantitative methods for analyzing the stability of respiration using four methods: phase space diagrams, Fourier spectra, Poincaré maps, and Lyapunov exponents. Respiratory patterns of 139 patients were grouped based on the combination of the regularity of amplitude, period, and baseline positions. Visual grading was done by inspecting the shape of diagram and classified into two states: regular and irregular. Quantitation was done by measuring standard deviation of x and v coordinates of Poincaré map (SD x , SD v ) or the height of the fundamental peak ( A 1 ) in Fourier spectrum or calculating the difference between maximal upward and downward drift. Each group showed characteristic pattern on visual analysis. There was difference of quantitative parameters (SD x , SD v , A 1 , and MUD-MDD) among four groups (one way ANOVA, p = 0.0001 for MUD-MDD, SD x , and SD v , p = 0.0002 for A 1 ). In ROC analysis, the cutoff values were 0.11 for SD x (AUC: 0.982, p < 0.0001), 0.062 for SD v (AUC: 0.847, p < 0.0001), 0.117 for A 1 (AUC: 0.876, p < 0.0001), and 0.349 for MUD-MDD (AUC: 0.948, p < 0.0001). This is the first study to analyze multiple aspects of respiration using various mathematical constructs and provides quantitative indices of respiratory stability and determining quantitative cutoff value for differentiating regular and irregular respiration.

  5. [A new method of processing quantitative PCR data].

    PubMed

    Ke, Bing-Shen; Li, Guang-Yun; Chen, Shi-Min; Huang, Xiang-Yan; Chen, Ying-Jian; Xu, Jun

    2003-05-01

    Today standard PCR can't satisfy the need of biotechnique development and clinical research any more. After numerous dynamic research, PE company found there is a linear relation between initial template number and cycling time when the accumulating fluorescent product is detectable.Therefore,they developed a quantitative PCR technique to be used in PE7700 and PE5700. But the error of this technique is too great to satisfy the need of biotechnique development and clinical research. A better quantitative PCR technique is needed. The mathematical model submitted here is combined with the achievement of relative science,and based on the PCR principle and careful analysis of molecular relationship of main members in PCR reaction system. This model describes the function relation between product quantity or fluorescence intensity and initial template number and other reaction conditions, and can reflect the accumulating rule of PCR product molecule accurately. Accurate quantitative PCR analysis can be made use this function relation. Accumulated PCR product quantity can be obtained from initial template number. Using this model to do quantitative PCR analysis,result error is only related to the accuracy of fluorescence intensity or the instrument used. For an example, when the fluorescence intensity is accurate to 6 digits and the template size is between 100 to 1,000,000, the quantitative result accuracy will be more than 99%. The difference of result error is distinct using same condition,same instrument but different analysis method. Moreover,if the PCR quantitative analysis system is used to process data, it will get result 80 times of accuracy than using CT method.

  6. Quantitative nephelometry

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003545.htm Quantitative nephelometry test To use the sharing features on this page, please enable JavaScript. Quantitative nephelometry is a lab test to quickly and ...

  7. Quantitation without Calibration: Response Profile as an Indicator of Target Amount.

    PubMed

    Debnath, Mrittika; Farace, Jessica M; Johnson, Kristopher D; Nesterova, Irina V

    2018-06-21

    Quantitative assessment of biomarkers is essential in numerous contexts from decision-making in clinical situations to food quality monitoring to interpretation of life-science research findings. However, appropriate quantitation techniques are not as widely addressed as detection methods. One of the major challenges in biomarker's quantitation is the need to have a calibration for correlating a measured signal to a target amount. The step complicates the methodologies and makes them less sustainable. In this work we address the issue via a new strategy: relying on position of response profile rather than on an absolute signal value for assessment of a target's amount. In order to enable the capability we develop a target-probe binding mechanism based on a negative cooperativity effect. A proof-of-concept example demonstrates that the model is suitable for quantitative analysis of nucleic acids over a wide concentration range. The general principles of the platform will be applicable toward a variety of biomarkers such as nucleic acids, proteins, peptides, and others.

  8. Quantitative Systems Pharmacology: A Case for Disease Models

    PubMed Central

    Ramanujan, S; Schmidt, BJ; Ghobrial, OG; Lu, J; Heatherington, AC

    2016-01-01

    Quantitative systems pharmacology (QSP) has emerged as an innovative approach in model‐informed drug discovery and development, supporting program decisions from exploratory research through late‐stage clinical trials. In this commentary, we discuss the unique value of disease‐scale “platform” QSP models that are amenable to reuse and repurposing to support diverse clinical decisions in ways distinct from other pharmacometrics strategies. PMID:27709613

  9. Value Types in Higher Education--Students' Perspective

    ERIC Educational Resources Information Center

    Dziewanowska, Katarzyna

    2017-01-01

    The purpose of the paper is to propose the service-dominant logic in marketing as a framework for analysing the value co-creation process in the higher education sector and present the results of a quantitative study (a survey) conducted among business students from four Polish public universities. The results of the study led to identification of…

  10. Civics Exam: Schools of Choice Boost Civic Values. PEPG/ 07-05

    ERIC Educational Resources Information Center

    Wolf, Patrick J.

    2007-01-01

    For this systematic review, the author examines 59 findings from 21 quantitative studies regarding the effects of school choice on seven civic values that relate to the capacity of individuals to perform as effective citizens in a representative democracy. The values, in order from the most studied to the least studied, are: (1) Political…

  11. Miniaturization of Fresnel lenses for solar concentration: a quantitative investigation.

    PubMed

    Duerr, Fabian; Meuret, Youri; Thienpont, Hugo

    2010-04-20

    Sizing down the dimensions of solar concentrators for photovoltaic applications offers a number of promising advantages. It provides thinner modules and smaller solar cells, which reduces thermal issues. In this work a plane Fresnel lens design is introduced that is first analyzed with geometrical optics. Because of miniaturization, pure ray tracing may no longer be valid to determine the concentration performance. Therefore, a quantitative wave optical analysis of the miniaturization's influence on the obtained concentration performance is presented. This better quantitative understanding of the impact of diffraction in microstructured Fresnel lenses might help to optimize the design of several applications in nonimaging optics.

  12. Comparison of contact conditions obtained by direct simulation with statistical analysis for normally distributed isotropic surfaces

    NASA Astrophysics Data System (ADS)

    Uchidate, M.

    2018-09-01

    In this study, with the aim of establishing a systematic knowledge on the impact of summit extraction methods and stochastic model selection in rough contact analysis, the contact area ratio (A r /A a ) obtained by statistical contact models with different summit extraction methods was compared with a direct simulation using the boundary element method (BEM). Fifty areal topography datasets with different autocorrelation functions in terms of the power index and correlation length were used for investigation. The non-causal 2D auto-regressive model which can generate datasets with specified parameters was employed in this research. Three summit extraction methods, Nayak’s theory, 8-point analysis and watershed segmentation, were examined. With regard to the stochastic model, Bhushan’s model and BGT (Bush-Gibson-Thomas) model were applied. The values of A r /A a from the stochastic models tended to be smaller than BEM. The discrepancy between the Bhushan’s model with the 8-point analysis and BEM was slightly smaller than Nayak’s theory. The results with the watershed segmentation was similar to those with the 8-point analysis. The impact of the Wolf pruning on the discrepancy between the stochastic analysis and BEM was not very clear. In case of the BGT model which employs surface gradients, good quantitative agreement against BEM was obtained when the Nayak’s bandwidth parameter was large.

  13. Inappropriate fiddling with statistical analyses to obtain a desirable p-value: tests to detect its presence in published literature.

    PubMed

    Gadbury, Gary L; Allison, David B

    2012-01-01

    Much has been written regarding p-values below certain thresholds (most notably 0.05) denoting statistical significance and the tendency of such p-values to be more readily publishable in peer-reviewed journals. Intuition suggests that there may be a tendency to manipulate statistical analyses to push a "near significant p-value" to a level that is considered significant. This article presents a method for detecting the presence of such manipulation (herein called "fiddling") in a distribution of p-values from independent studies. Simulations are used to illustrate the properties of the method. The results suggest that the method has low type I error and that power approaches acceptable levels as the number of p-values being studied approaches 1000.

  14. Detection and quantitation of Kaposi's sarcoma-associated herpesvirus (KSHV) by a single competitive-quantitative polymerase chain reaction.

    PubMed

    Curreli, Francesca; Robles, Monica A; Friedman-Kien, Alvin E; Flore, Ornella

    2003-02-01

    Kaposi's sarcoma-associated herpesvirus is a novel herpesvirus linked to AIDS-related neoplasms. Currently it is difficult to evaluate the number of virions in viral preparation or in samples obtained from patients with Kaposi's sarcoma (KS), since no protocol for determining the plaque forming units of KSHV exists. We constructed a fragment of a different size than the target viral DNA to carry out a competitive-quantitative PCR. Both fragment and viral DNA were added to a single PCR reaction to compete for the same set of primers. By knowing the amount of the competitor added to the reaction, we could determine the number of viral DNA molecules. We used this assay successfully to detect and quantify KSHV genomes from KS skin biopsies and pleural effusion lymphoma, and from different viral preparations. To date, this is the most convenient and economic method that allows an accurate and fast viral detection/quantitation with a single PCR.

  15. Exploring the Perceptions of College Instructors towards Computer Simulation Software Programs: A Quantitative Study

    ERIC Educational Resources Information Center

    Punch, Raymond J.

    2012-01-01

    The purpose of the quantitative regression study was to explore and to identify relationships between attitudes toward use and perceptions of value of computer-based simulation programs, of college instructors, toward computer based simulation programs. A relationship has been reported between attitudes toward use and perceptions of the value of…

  16. High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

    NASA Technical Reports Server (NTRS)

    Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.

    2002-01-01

    A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

  17. Separation of input function for rapid measurement of quantitative CMRO2 and CBF in a single PET scan with a dual tracer administration method

    NASA Astrophysics Data System (ADS)

    Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Iida, Hidehiro

    2007-04-01

    Cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF) and cerebral blood flow (CBF) images can be quantified using positron emission tomography (PET) by administrating 15O-labelled water (H152O) and oxygen (15O2). Conventionally, those images are measured with separate scans for three tracers C15O for CBV, H152O for CBF and 15O2 for CMRO2, and there are additional waiting times between the scans in order to minimize the influence of the radioactivity from the previous tracers, which results in a relatively long study period. We have proposed a dual tracer autoradiographic (DARG) approach (Kudomi et al 2005), which enabled us to measure CBF, OEF and CMRO2 rapidly by sequentially administrating H152O and 15O2 within a short time. Because quantitative CBF and CMRO2 values are sensitive to arterial input function, it is necessary to obtain accurate input function and a drawback of this approach is to require separation of the measured arterial blood time-activity curve (TAC) into pure water and oxygen input functions under the existence of residual radioactivity from the first injected tracer. For this separation, frequent manual sampling was required. The present paper describes two calculation methods: namely a linear and a model-based method, to separate the measured arterial TAC into its water and oxygen components. In order to validate these methods, we first generated a blood TAC for the DARG approach by combining the water and oxygen input functions obtained in a series of PET studies on normal human subjects. The combined data were then separated into water and oxygen components by the present methods. CBF and CMRO2 were calculated using those separated input functions and tissue TAC. The quantitative accuracy in the CBF and CMRO2 values by the DARG approach did not exceed the acceptable range, i.e., errors in those values were within 5%, when the area under the curve in the input function of the second tracer was larger than half of the

  18. A general way for quantitative magnetic measurement by transmitted electrons

    NASA Astrophysics Data System (ADS)

    Song, Dongsheng; Li, Gen; Cai, Jianwang; Zhu, Jing

    2016-01-01

    EMCD (electron magnetic circular dichroism) technique opens a new door to explore magnetic properties by transmitted electrons. The recently developed site-specific EMCD technique makes it possible to obtain rich magnetic information from the Fe atoms sited at nonequivalent crystallographic planes in NiFe2O4, however it is based on a critical demand for the crystallographic structure of the testing sample. Here, we have further improved and tested the method for quantitative site-specific magnetic measurement applicable for more complex crystallographic structure by using the effective dynamical diffraction effects (general routine for selecting proper diffraction conditions, making use of the asymmetry of dynamical diffraction for design of experimental geometry and quantitative measurement, etc), and taken yttrium iron garnet (Y3Fe5O12, YIG) with more complex crystallographic structure as an example to demonstrate its applicability. As a result, the intrinsic magnetic circular dichroism signals, spin and orbital magnetic moment of iron with site-specific are quantitatively determined. The method will further promote the development of quantitative magnetic measurement with high spatial resolution by transmitted electrons.

  19. Social Return on Investment: Valuing health outcomes or promoting economic values?

    PubMed

    Leck, Chris; Upton, Dominic; Evans, Nick

    2016-07-01

    Interventions and activities that influence health are often concerned with intangible outcomes that are difficult to value despite their potential significance. Social Return on Investment is an evaluation framework that explores all aspects of change and expresses these in comparable terms. It combines qualitative narratives and quantitative measurements with a financial approach to enable outcomes that can otherwise be overlooked or undervalued to be incorporated appropriately. This article presents Social Return on Investment as an effective tool for supporting the development of a holistic appreciation of how interventions impact on the health and well-being of individuals, communities and societies. © The Author(s) 2014.

  20. Methodological aspects of multicenter studies with quantitative PET.

    PubMed

    Boellaard, Ronald

    2011-01-01

    Quantification of whole-body FDG PET studies is affected by many physiological and physical factors. Much of the variability in reported standardized uptake value (SUV) data seen in the literature results from the variability in methodology applied among these studies, i.e., due to the use of different scanners, acquisition and reconstruction settings, region of interest strategies, SUV normalization, and/or corrections methods. To date, the variability in applied methodology prohibits a proper comparison and exchange of quantitative FDG PET data. Consequently, the promising role of quantitative PET has been demonstrated in several monocentric studies, but these published results cannot be used directly as a guideline for clinical (multicenter) trials performed elsewhere. In this chapter, the main causes affecting whole-body FDG PET quantification and strategies to minimize its inter-institute variability are addressed.

  1. Quantitative Residual Strain Analyses on Strain Hardened Nickel Based Alloy

    NASA Astrophysics Data System (ADS)

    Yonezawa, Toshio; Maeguchi, Takaharu; Goto, Toru; Juan, Hou

    Many papers have reported about the effects of strain hardening by cold rolling, grinding, welding, etc. on stress corrosion cracking susceptibility of nickel based alloys and austenitic stainless steels for LWR pipings and components. But, the residual strain value due to cold rolling, grinding, welding, etc. is not so quantitatively evaluated.

  2. Development of a programmable standard of ultra-low capacitance values.

    PubMed

    Khan, M S; Séron, O; Thuillier, G; Thévenot, O; Gournay, P; Piquemal, F

    2017-05-01

    A set of ultra-low value capacitance standards together with a programmable coaxial multiplexer (mux) have been developed. The mux allows the connection of these capacitances in parallel configuration and they together form the programmable capacitance standard. It is capable of producing decadic standard capacitances from 10 aF to at least 0.1 pF, which are later used to calibrate commercial precision capacitance bridges. This paper describes the realization and the characterization of this standard together with results obtained during the calibration of Andeen-Hagerling AH2700A bridges with a maximum uncertainty of 0.8 aF for all the capacitances generated ranging from 10 aF to 0.1 pF, at 1 kHz. These latter could be then integrated to functionalized AFMs or probe stations for quantitative capacitance measurements. Sources of uncertainties of the programmable capacitance standard, such as parasitic effects due to stray impedances, are evaluated and a method to overcome these hindrances is also discussed.

  3. Cardiovascular and pulmonary dynamics by quantitative imaging

    NASA Technical Reports Server (NTRS)

    Wood, E. H.

    1976-01-01

    The accuracy and range of studies on cardiovascular and pulmonary functions can be greatly facilitated if the motions of the underlying organ systems throughout individual cycles can be directly visualized and readily measured with minimum or preferably no effect on these motions. Achievement of this objective requires development of techniques for quantitative noninvasive or minimally invasive dynamic and stop-action imaging of the organ systems. A review of advances in dynamic quantitative imaging of moving organs reveals that the revolutionary value of cross-sectional and three-dimensional images produced by various types of radiant energy such as X-rays and gamma rays, positrons, electrons, protons, light, and ultrasound for clinical diagnostic and biomedical research applications is just beginning to be realized. The fabrication of a clinically useful cross-section reconstruction device with sensing capabilities for both anatomical structural composition and chemical composition may be possible and awaits future development.

  4. Sieve-based device for MALDI sample preparation. III. Its power for quantitative measurements.

    PubMed

    Molin, Laura; Cristoni, Simone; Seraglia, Roberta; Traldi, Pietro

    2011-02-01

    The solid sample inhomogeneity is a weak point of traditional MALDI deposition techniques that reflects negatively on quantitative analysis. The recently developed sieve-based device (SBD) sample deposition method, based on the electrospraying of matrix/analyte solutions through a grounded sieve, allows the homogeneous deposition of microcrystals with dimensions smaller than that of the laser spot. In each microcrystal the matrix/analyte molar ratio can be considered constant. Then, by irradiating different portions of the microcrystal distribution an identical response is obtained. This result suggests the employment of SBD in the development of quantitative procedures. For this aim, mixtures of different proteins of known molarity were analyzed, showing a good relationship between molarity and intensity ratios. This behaviour was also observed in the case of proteins with quite different ionic yields. The power of the developed method for quantitative evaluation was also tested by the measurement of the abundance of IGPP[Oxi]GPP[Oxi]GLMGPP (m/z 1219) present in the collagen-α-5(IV) chain precursor, differently expressed in urines from healthy subjects and diabetic-nephropathic patients, confirming its overexpression in the presence of nephropathy. The data obtained indicate that SBD is a particularly effective method for quantitative analysis also in biological fluids of interest. Copyright © 2011 John Wiley & Sons, Ltd.

  5. Subsurface imaging and cell refractometry using quantitative phase/ shear-force feedback microscopy

    NASA Astrophysics Data System (ADS)

    Edward, Kert; Farahi, Faramarz

    2009-10-01

    Over the last few years, several novel quantitative phase imaging techniques have been developed for the study of biological cells. However, many of these techniques are encumbered by inherent limitations including 2π phase ambiguities and diffraction limited spatial resolution. In addition, subsurface information in the phase data is not exploited. We hereby present a novel quantitative phase imaging system without 2 π ambiguities, which also allows for subsurface imaging and cell refractometry studies. This is accomplished by utilizing simultaneously obtained shear-force topography information. We will demonstrate how the quantitative phase and topography data can be used for subsurface and cell refractometry analysis and will present results for a fabricated structure and a malaria infected red blood cell.

  6. Image-derived arterial input function for quantitative fluorescence imaging of receptor-drug binding in vivo

    PubMed Central

    Elliott, Jonathan T.; Samkoe, Kimberley S.; Davis, Scott C.; Gunn, Jason R.; Paulsen, Keith D.; Roberts, David W.; Pogue, Brian W.

    2017-01-01

    Receptor concentration imaging (RCI) with targeted-untargeted optical dye pairs has enabled in vivo immunohistochemistry analysis in preclinical subcutaneous tumors. Successful application of RCI to fluorescence guided resection (FGR), so that quantitative molecular imaging of tumor-specific receptors could be performed in situ, would have a high impact. However, assumptions of pharmacokinetics, permeability and retention, as well as the lack of a suitable reference region limit the potential for RCI in human neurosurgery. In this study, an arterial input graphic analysis (AIGA) method is presented which is enabled by independent component analysis (ICA). The percent difference in arterial concentration between the image-derived arterial input function (AIFICA) and that obtained by an invasive method (ICACAR) was 2.0 ± 2.7% during the first hour of circulation of a targeted-untargeted dye pair in mice. Estimates of distribution volume and receptor concentration in tumor bearing mice (n = 5) recovered using the AIGA technique did not differ significantly from values obtained using invasive AIF measurements (p=0.12). The AIGA method, enabled by the subject-specific AIFICA, was also applied in a rat orthotopic model of U-251 glioblastoma to obtain the first reported receptor concentration and distribution volume maps during open craniotomy. PMID:26349671

  7. Quantitative PCR for human herpesviruses 6 and 7.

    PubMed Central

    Secchiero, P; Zella, D; Crowley, R W; Gallo, R C; Lusso, P

    1995-01-01

    A quantitative PCR assay for the detection of human herpesvirus 6 (HHV-6) (variants A and B) and HHV-7 DNAs in clinical samples was developed. The assay uses a nonhomologous internal standard (IS) for each virus that is coamplified with the wild-type target sequence in the same vial and with the same pair of primers. This method allows for a correction of the variability of efficiency of the PCR technique. A standard curve is constructed for each experiment by coamplification of known quantities of the cloned HHV-6 or HHV-7 target templates with the respective IS. Absolute quantitation of the test samples is then achieved by determining the viral target/IS ratio of the hybridization signals of the amplification products and plotting this value against the standard curve. Using this assay, we quantitated the amount of HHV-6 or HHV-7 DNA in infected cell cultures and demonstrated an inhibitory effect of phosphonoformic acid on the replication of HHV-6 and HHV-7 in vitro. As the first clinical application of this procedure, we performed preliminary measurements of the loads of HHV-6 and HHV-7 in lymph nodes from patients with Hodgkin's disease and AIDS. Application of this quantitative PCR method should be helpful for elucidating the pathogenic roles of HHV-6 and HHV-7. PMID:7559960

  8. ADvanced IMage Algebra (ADIMA): a novel method for depicting multiple sclerosis lesion heterogeneity, as demonstrated by quantitative MRI.

    PubMed

    Yiannakas, Marios C; Tozer, Daniel J; Schmierer, Klaus; Chard, Declan T; Anderson, Valerie M; Altmann, Daniel R; Miller, David H; Wheeler-Kingshott, Claudia A M

    2013-05-01

    There are modest correlations between multiple sclerosis (MS) disability and white matter lesion (WML) volumes, as measured by T2-weighted (T2w) magnetic resonance imaging (MRI) scans (T2-WML). This may partly reflect pathological heterogeneity in WMLs, which is not apparent on T2w scans. To determine if ADvanced IMage Algebra (ADIMA), a novel MRI post-processing method, can reveal WML heterogeneity from proton-density weighted (PDw) and T2w images. We obtained conventional PDw and T2w images from 10 patients with relapsing-remitting MS (RRMS) and ADIMA images were calculated from these. We classified all WML into bright (ADIMA-b) and dark (ADIMA-d) sub-regions, which were segmented. We obtained conventional T2-WML and T1-WML volumes for comparison, as well as the following quantitative magnetic resonance parameters: magnetisation transfer ratio (MTR), T1 and T2. Also, we assessed the reproducibility of the segmentation for ADIMA-b, ADIMA-d and T2-WML. Our study's ADIMA-derived volumes correlated with conventional lesion volumes (p < 0.05). ADIMA-b exhibited higher T1 and T2, and lower MTR than the T2-WML (p < 0.001). Despite the similarity in T1 values between ADIMA-b and T1-WML, these regions were only partly overlapping with each other. ADIMA-d exhibited quantitative characteristics similar to T2-WML; however, they were only partly overlapping. Mean intra- and inter-observer coefficients of variation for ADIMA-b, ADIMA-d and T2-WML volumes were all < 6 % and < 10 %, respectively. ADIMA enabled the simple classification of WML into two groups having different quantitative magnetic resonance properties, which can be reproducibly distinguished.

  9. ADvanced IMage Algebra (ADIMA): a novel method for depicting multiple sclerosis lesion heterogeneity, as demonstrated by quantitative MRI

    PubMed Central

    Tozer, Daniel J; Schmierer, Klaus; Chard, Declan T; Anderson, Valerie M; Altmann, Daniel R; Miller, David H; Wheeler-Kingshott, Claudia AM

    2013-01-01

    Background: There are modest correlations between multiple sclerosis (MS) disability and white matter lesion (WML) volumes, as measured by T2-weighted (T2w) magnetic resonance imaging (MRI) scans (T2-WML). This may partly reflect pathological heterogeneity in WMLs, which is not apparent on T2w scans. Objective: To determine if ADvanced IMage Algebra (ADIMA), a novel MRI post-processing method, can reveal WML heterogeneity from proton-density weighted (PDw) and T2w images. Methods: We obtained conventional PDw and T2w images from 10 patients with relapsing–remitting MS (RRMS) and ADIMA images were calculated from these. We classified all WML into bright (ADIMA-b) and dark (ADIMA-d) sub-regions, which were segmented. We obtained conventional T2-WML and T1-WML volumes for comparison, as well as the following quantitative magnetic resonance parameters: magnetisation transfer ratio (MTR), T1 and T2. Also, we assessed the reproducibility of the segmentation for ADIMA-b, ADIMA-d and T2-WML. Results: Our study’s ADIMA-derived volumes correlated with conventional lesion volumes (p < 0.05). ADIMA-b exhibited higher T1 and T2, and lower MTR than the T2-WML (p < 0.001). Despite the similarity in T1 values between ADIMA-b and T1-WML, these regions were only partly overlapping with each other. ADIMA-d exhibited quantitative characteristics similar to T2-WML; however, they were only partly overlapping. Mean intra- and inter-observer coefficients of variation for ADIMA-b, ADIMA-d and T2-WML volumes were all < 6 % and < 10 %, respectively. Conclusion: ADIMA enabled the simple classification of WML into two groups having different quantitative magnetic resonance properties, which can be reproducibly distinguished. PMID:23037551

  10. Facile and quantitative electrochemical detection of yeast cell apoptosis

    NASA Astrophysics Data System (ADS)

    Yue, Qiulin; Xiong, Shiquan; Cai, Dongqing; Wu, Zhengyan; Zhang, Xin

    2014-03-01

    An electrochemical method based on square wave anodic stripping voltammetry (SWASV) was developed to detect the apoptosis of yeast cells conveniently and quantitatively through the high affinity between Cu2+ and phosphatidylserine (PS) translocated from the inner to the outer plasma membrane of the apoptotic cells. The combination of negatively charged PS and Cu2+ could decrease the electrochemical response of Cu2+ on the electrode. The results showed that the apoptotic rates of cells could be detected quantitatively through the variations of peak currents of Cu2+ by SWASV, and agreed well with those obtained through traditional flow cytometry detection. This work thus may provide a novel, simple, immediate and accurate detection method for cell apoptosis.

  11. Formation resistivity measurements from within a cased well used to quantitatively determine the amount of oil and gas present

    DOEpatents

    Vail, III, William B.

    1997-01-01

    Methods to quantitatively determine the separate amounts of oil and gas in a geological formation adjacent to a cased well using measurements of formation resistivity are disclosed. The steps include obtaining resistivity measurements from within a cased well of a given formation, obtaining the porosity, obtaining the resistivity of formation water present, computing the combined amounts of oil and gas present using Archie's Equations, determining the relative amounts of oil and gas present from measurements within a cased well, and then quantitatively determining the separate amounts of oil and gas present in the formation.

  12. Simulated linear test applied to quantitative proteomics.

    PubMed

    Pham, T V; Jimenez, C R

    2016-09-01

    Omics studies aim to find significant changes due to biological or functional perturbation. However, gene and protein expression profiling experiments contain inherent technical variation. In discovery proteomics studies where the number of samples is typically small, technical variation plays an important role because it contributes considerably to the observed variation. Previous methods place both technical and biological variations in tightly integrated mathematical models that are difficult to adapt for different technological platforms. Our aim is to derive a statistical framework that allows the inclusion of a wide range of technical variability. We introduce a new method called the simulated linear test, or the s-test, that is easy to implement and easy to adapt for different models of technical variation. It generates virtual data points from the observed values according to a pre-defined technical distribution and subsequently employs linear modeling for significance analysis. We demonstrate the flexibility of the proposed approach by deriving a new significance test for quantitative discovery proteomics for which missing values have been a major issue for traditional methods such as the t-test. We evaluate the result on two label-free (phospho) proteomics datasets based on ion-intensity quantitation. Available at http://www.oncoproteomics.nl/software/stest.html : t.pham@vumc.nl. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  13. Cultural values and population health: a quantitative analysis of variations in cultural values, health behaviours and health outcomes among 42 European countries.

    PubMed

    Mackenbach, Johan P

    2014-07-01

    Variations in 'culture' are often invoked to explain cross-national variations in health, but formal analyses of this relation are scarce. We studied the relation between three sets of cultural values and a wide range of health behaviours and health outcomes in Europe. Cultural values were measured according to Inglehart׳s two, Hofstede׳s six, and Schwartz׳s seven dimensions. Data on individual and collective health behaviours (30 indicators of fertility-related behaviours, adult lifestyles, use of preventive services, prevention policies, health care policies, and environmental policies) and health outcomes (35 indicators of general health and of specific health problems relating to fertility, adult lifestyles, prevention, health care, and violence) in 42 European countries around the year 2010 were extracted from harmonized international data sources. Multivariate regression analysis was used to relate health behaviours to value orientations, controlling for socioeconomic confounders. In univariate analyses, all scales are related to health behaviours and most scales are related to health outcomes, but in multivariate analyses Inglehart׳s 'self-expression' (versus 'survival') scale has by far the largest number of statistically significant associations. Countries with higher scores on 'self-expression' have better outcomes on 16 out of 30 health behaviours and on 19 out of 35 health indicators, and variations on this scale explain up to 26% of the variance in these outcomes in Europe. In mediation analyses the associations between cultural values and health outcomes are partly explained by differences in health behaviours. Variations in cultural values also appear to account for some of the striking variations in health behaviours between neighbouring countries in Europe (Sweden and Denmark, the Netherlands and Belgium, the Czech Republic and Slovakia, and Estonia and Latvia). This study is the first to provide systematic and coherent empirical evidence that

  14. Quantitative Functional Imaging Using Dynamic Positron Computed Tomography and Rapid Parameter Estimation Techniques

    NASA Astrophysics Data System (ADS)

    Koeppe, Robert Allen

    Positron computed tomography (PCT) is a diagnostic imaging technique that provides both three dimensional imaging capability and quantitative measurements of local tissue radioactivity concentrations in vivo. This allows the development of non-invasive methods that employ the principles of tracer kinetics for determining physiological properties such as mass specific blood flow, tissue pH, and rates of substrate transport or utilization. A physiologically based, two-compartment tracer kinetic model was derived to mathematically describe the exchange of a radioindicator between blood and tissue. The model was adapted for use with dynamic sequences of data acquired with a positron tomograph. Rapid estimation techniques were implemented to produce functional images of the model parameters by analyzing each individual pixel sequence of the image data. A detailed analysis of the performance characteristics of three different parameter estimation schemes was performed. The analysis included examination of errors caused by statistical uncertainties in the measured data, errors in the timing of the data, and errors caused by violation of various assumptions of the tracer kinetic model. Two specific radioindicators were investigated. ('18)F -fluoromethane, an inert freely diffusible gas, was used for local quantitative determinations of both cerebral blood flow and tissue:blood partition coefficient. A method was developed that did not require direct sampling of arterial blood for the absolute scaling of flow values. The arterial input concentration time course was obtained by assuming that the alveolar or end-tidal expired breath radioactivity concentration is proportional to the arterial blood concentration. The scale of the input function was obtained from a series of venous blood concentration measurements. The method of absolute scaling using venous samples was validated in four studies, performed on normal volunteers, in which directly measured arterial concentrations

  15. The simultaneous quantitation of ten amino acids in soil extracts by mass fragmentography

    NASA Technical Reports Server (NTRS)

    Pereira, W. E.; Hoyano, Y.; Reynolds, W. E.; Summons, R. E.; Duffield, A. M.

    1972-01-01

    A specific and sensitive method for the identification and simultaneous quantitation by mass fragmentography of ten of the amino acids present in soil was developed. The technique uses a computer driven quadrupole mass spectrometer and a commercial preparation of deuterated amino acids is used as internal standards for purposes of quantitation. The results obtained are comparable with those from an amino acid analyzer. In the quadrupole mass spectrometer-computer system up to 25 pre-selected ions may be monitored sequentially. This allows a maximum of 12 different amino acids (one specific ion in each of the undeuterated and deuterated amino acid spectra) to be quantitated. The method is relatively rapid (analysis time of approximately one hour) and is capable of the quantitation of nanogram quantities of amino acids.

  16. Comparison of fractal dimensions based on segmented NDVI fields obtained from different remote sensors.

    NASA Astrophysics Data System (ADS)

    Alonso, C.; Benito, R. M.; Tarquis, A. M.

    2012-04-01

    Satellite image data have become an important source of information for monitoring vegetation and mapping land cover at several scales. Beside this, the distribution and phenology of vegetation is largely associated with climate, terrain characteristics and human activity. Various vegetation indices have been developed for qualitative and quantitative assessment of vegetation using remote spectral measurements. In particular, sensors with spectral bands in the red (RED) and near-infrared (NIR) lend themselves well to vegetation monitoring and based on them [(NIR - RED) / (NIR + RED)] Normalized Difference Vegetation Index (NDVI) has been widespread used. Given that the characteristics of spectral bands in RED and NIR vary distinctly from sensor to sensor, NDVI values based on data from different instruments will not be directly comparable. The spatial resolution also varies significantly between sensors, as well as within a given scene in the case of wide-angle and oblique sensors. As a result, NDVI values will vary according to combinations of the heterogeneity and scale of terrestrial surfaces and pixel footprint sizes. Therefore, the question arises as to the impact of differences in spectral and spatial resolutions on vegetation indices like the NDVI. The aim of this study is to establish a comparison between two different sensors in their NDVI values at different spatial resolutions. Scaling analysis and modeling techniques are increasingly understood to be the result of nonlinear dynamic mechanisms repeating scale after scale from large to small scales leading to non-classical resolution dependencies. In the remote sensing framework the main characteristic of sensors images is the high local variability in their values. This variability is a consequence of the increase in spatial and radiometric resolution that implies an increase in complexity that it is necessary to characterize. Fractal and multifractal techniques has been proven to be useful to extract

  17. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR.

    PubMed

    Cox, Jennie; Indugula, Reshmi; Vesper, Stephen; Zhu, Zheng; Jandarov, Roman; Reponen, Tiina

    2017-10-18

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample collected with a Button™ inhalable aerosol sampler and four types of dust samples: a vacuumed floor dust sample, newly settled dust collected for four weeks onto two types of electrostatic dust cloths (EDCs) in trays, and a wipe sample of dust from above floor surfaces. The samples were obtained in the bedrooms of asthmatic children (n = 14). Quantitative polymerase chain reaction (qPCR) was used to analyze the dust and air samples for the 36 fungal species that make up the Environmental Relative Moldiness Index (ERMI). The results from the samples were compared by four matrices: total concentration of fungal cells, concentration of fungal species associated with indoor environments, concentration of fungal species associated with outdoor environments, and ERMI values (or ERMI-like values for air samples). The ERMI values for the dust samples and the ERMI-like values for the 48 hour air samples were not significantly different. The total cell concentrations of the 36 species obtained with the four dust collection methods correlated significantly (r = 0.64-0.79, p < 0.05), with the exception of the vacuumed floor dust and newly settled dust. In addition, fungal cell concentrations of indoor associated species correlated well between all four dust sampling methods (r = 0.68-0.86, p < 0.01). No correlation was found between the fungal concentrations in the air and dust samples primarily because of differences in concentrations of Cladosporium cladosporioides Type 1 and Epicoccum nigrum. A representative type of dust sample and a 48 hour air sample might both provide useful information about fungal exposures.

  18. Using a Standardized Clinical Quantitative Sensory Testing Battery to Judge the Clinical Relevance of Sensory Differences Between Adjacent Body Areas.

    PubMed

    Dimova, Violeta; Oertel, Bruno G; Lötsch, Jörn

    2017-01-01

    Skin sensitivity to sensory stimuli varies among different body areas. A standardized clinical quantitative sensory testing (QST) battery, established for the diagnosis of neuropathic pain, was used to assess whether the magnitude of differences between test sites reaches clinical significance. Ten different sensory QST measures derived from thermal and mechanical stimuli were obtained from 21 healthy volunteers (10 men) and used to create somatosensory profiles bilateral from the dorsum of the hands (the standard area for the assessment of normative values for the upper extremities as proposed by the German Research Network on Neuropathic Pain) and bilateral at volar forearms as a neighboring nonstandard area. The parameters obtained were statistically compared between test sites. Three of the 10 QST parameters differed significantly with respect to the "body area," that is, warmth detection, thermal sensory limen, and mechanical pain thresholds. After z-transformation and interpretation according to the QST battery's standard instructions, 22 abnormal values were obtained at the hand. Applying the same procedure to parameters assessed at the nonstandard site forearm, that is, z-transforming them to the reference values for the hand, 24 measurements values emerged as abnormal, which was not significantly different compared with the hand (P=0.4185). Sensory differences between neighboring body areas are statistically significant, reproducing prior knowledge. This has to be considered in scientific assessments where a small variation of the tested body areas may not be an option. However, the magnitude of these differences was below the difference in sensory parameters that is judged as abnormal, indicating a robustness of the QST instrument against protocol deviations with respect to the test area when using the method of comparison with a 95 % confidence interval of a reference dataset.

  19. Quantitative surface topography assessment of directly compressed and roller compacted tablet cores using photometric stereo image analysis.

    PubMed

    Allesø, Morten; Holm, Per; Carstensen, Jens Michael; Holm, René

    2016-05-25

    Surface topography, in the context of surface smoothness/roughness, was investigated by the use of an image analysis technique, MultiRay™, related to photometric stereo, on different tablet batches manufactured either by direct compression or roller compaction. In the present study, oblique illumination of the tablet (darkfield) was considered and the area of cracks and pores in the surface was used as a measure of tablet surface topography; the higher a value, the rougher the surface. The investigations demonstrated a high precision of the proposed technique, which was able to rapidly (within milliseconds) and quantitatively measure the obtained surface topography of the produced tablets. Compaction history, in the form of applied roll force and tablet punch pressure, was also reflected in the measured smoothness of the tablet surfaces. Generally it was found that a higher degree of plastic deformation of the microcrystalline cellulose resulted in a smoother tablet surface. This altogether demonstrated that the technique provides the pharmaceutical developer with a reliable, quantitative response parameter for visual appearance of solid dosage forms, which may be used for process and ultimately product optimization. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR.

    PubMed

    Kero, Tanja; Nordström, Jonny; Harms, Hendrik J; Sörensen, Jens; Ahlström, Håkan; Lubberink, Mark

    2017-12-01

    The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent 15 O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values. Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00. PET-MR-based MBF values correlated well with PET-CT-based MBF values and