2013-01-01
Background The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Methods and findings Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China. The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Conclusions Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships. PMID:23497145
Yang, Qingsheng; Mwenda, Kevin M; Ge, Miao
2013-03-12
The measurement of the Erythrocyte Sedimentation Rate (ESR) value is a standard procedure performed during a typical blood test. In order to formulate a unified standard of establishing reference ESR values, this paper presents a novel prediction model in which local normal ESR values and corresponding geographical factors are used to predict reference ESR values using multi-layer feed-forward artificial neural networks (ANN). Local normal ESR values were obtained from hospital data, while geographical factors that include altitude, sunshine hours, relative humidity, temperature and precipitation were obtained from the National Geographical Data Information Centre in China.The results show that predicted values are statistically in agreement with measured values. Model results exhibit significant agreement between training data and test data. Consequently, the model is used to predict the unseen local reference ESR values. Reference ESR values can be established with geographical factors by using artificial intelligence techniques. ANN is an effective method for simulating and predicting reference ESR values because of its ability to model nonlinear and complex relationships.
Reliability of reference distances used in photogrammetry.
Aksu, Muge; Kaya, Demet; Kocadereli, Ilken
2010-07-01
To determine the reliability of the reference distances used for photogrammetric assessment. The sample consisted of 100 subjects with mean ages of 22.97 +/- 2.98 years. Five lateral and four frontal parameters were measured directly on the subjects' faces. For photogrammetric assessment, two reference distances for the profile view and three reference distances for the frontal view were established. Standardized photographs were taken and all the parameters that had been measured directly on the face were measured on the photographs. The reliability of the reference distances was checked by comparing direct and indirect values of the parameters obtained from the subjects' faces and photographs. Repeated measure analysis of variance (ANOVA) and Bland-Altman analyses were used for statistical assessment. For profile measurements, the indirect values measured were statistically different from the direct values except for Sn-Sto in male subjects and Prn-Sn and Sn-Sto in female subjects. The indirect values of Prn-Sn and Sn-Sto were reliable in both sexes. The poorest results were obtained in the indirect values of the N-Sn parameter for female subjects and the Sn-Me parameter for male subjects according to the Sa-Sba reference distance. For frontal measurements, the indirect values were statistically different from the direct values in both sexes except for one in male subjects. The indirect values measured were not statistically different from the direct values for Go-Go. The indirect values of Ch-Ch were reliable in male subjects. The poorest results were obtained according to the P-P reference distance. For profile assessment, the T-Ex reference distance was reliable for Prn-Sn and Sn-Sto in both sexes. For frontal assessment, Ex-Ex and En-En reference distances were reliable for Ch-Ch in male subjects.
Estimation of reference intervals from small samples: an example using canine plasma creatinine.
Geffré, A; Braun, J P; Trumel, C; Concordet, D
2009-12-01
According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
Junction Potentials Bias Measurements of Ion Exchange Membrane Permselectivity.
Kingsbury, Ryan S; Flotron, Sophie; Zhu, Shan; Call, Douglas F; Coronell, Orlando
2018-04-17
Ion exchange membranes (IEMs) are versatile materials relevant to a variety of water and waste treatment, energy production, and industrial separation processes. The defining characteristic of IEMs is their ability to selectively allow positive or negative ions to permeate, which is referred to as permselectivity. Measured values of permselectivity that equal unity (corresponding to a perfectly selective membrane) or exceed unity (theoretically impossible) have been reported for cation exchange membranes (CEMs). Such nonphysical results call into question our ability to correctly measure this crucial membrane property. Because weighing errors, temperature, and measurement uncertainty have been shown to not explain these anomalous permselectivity results, we hypothesized that a possible explanation are junction potentials that occur at the tips of reference electrodes. In this work, we tested this hypothesis by comparing permselectivity values obtained from bare Ag/AgCl wire electrodes (which have no junction) to values obtained from single-junction reference electrodes containing two different electrolytes. We show that permselectivity values obtained using reference electrodes with junctions were greater than unity for CEMs. In contrast, electrodes without junctions always produced permselectivities lower than unity. Electrodes with junctions also resulted in artificially low permselectivity values for AEMs compared to electrodes without junctions. Thus, we conclude that junctions in reference electrodes introduce two biases into results in the IEM literature: (i) permselectivity values larger than unity for CEMs and (ii) lower permselectivity values for AEMs compared to those for CEMs. These biases can be avoided by using electrodes without a junction.
Optimal weighted combinatorial forecasting model of QT dispersion of ECGs in Chinese adults.
Wen, Zhang; Miao, Ge; Xinlei, Liu; Minyi, Cen
2016-07-01
This study aims to provide a scientific basis for unifying the reference value standard of QT dispersion of ECGs in Chinese adults. Three predictive models including regression model, principal component model, and artificial neural network model are combined to establish the optimal weighted combination model. The optimal weighted combination model and single model are verified and compared. Optimal weighted combinatorial model can reduce predicting risk of single model and improve the predicting precision. The reference value of geographical distribution of Chinese adults' QT dispersion was precisely made by using kriging methods. When geographical factors of a particular area are obtained, the reference value of QT dispersion of Chinese adults in this area can be estimated by using optimal weighted combinatorial model and reference value of the QT dispersion of Chinese adults anywhere in China can be obtained by using geographical distribution figure as well.
[Reference values of energy for the Venezuelan population].
Landaeta-Jiménez, Maritza; Aliaga, Carla; Sifontes, Yaritza; Vásquez, Maura; Ramírez, Guillermo; Falque Madrid, Luís; Herrera, Marianella; María Reyes, Ana; Emilia, Elzakem; Herrera, Ctor; Bernal, Jennifer
2013-12-01
The project of updating the Venezuelan energy reference values respond to the recommendations made by an FAO experts committee, several decades ago for the countries assuming this work. Because of the dramatic changes experienced globally regarding energy intake/expenditure and particularly variations on the Venezuelan nutritional scenario with the presence of "the double burden of malnutrition" it a review of Energy Reference Values (VRE) from a more integral approach is pertinent. This report follows the methodology proposed by FAO/WHO/UNU 2004 experts committee and energy reference values were established by group of age and gender, also average energy values for Venezuelan population were obtained. For calculation of these requirements, the energy expenditure was included by taking into account Basal Metabolic Rate and physical activity level for some specific groups. The score average values updated in 2012 of 2.200 kcal/dia reported to be lower than those of 2000 at all ages for masculine gender except for the 16-17 age group and for feminine gender just until ages 10-12 years and from there are slightly above the values obtained in 2000.
The conventional tuning fork as a quantitative tool for vibration threshold.
Alanazy, Mohammed H; Alfurayh, Nuha A; Almweisheer, Shaza N; Aljafen, Bandar N; Muayqil, Taim
2018-01-01
This study was undertaken to describe a method for quantifying vibration when using a conventional tuning fork (CTF) in comparison to a Rydel-Seiffer tuning fork (RSTF) and to provide reference values. Vibration thresholds at index finger and big toe were obtained in 281 participants. Spearman's correlations were performed. Age, weight, and height were analyzed for their covariate effects on vibration threshold. Reference values at the fifth percentile were obtained by quantile regression. The correlation coefficients between CTF and RSTF values at finger/toe were 0.59/0.64 (P = 0.001 for both). Among covariates, only age had a significant effect on vibration threshold. Reference values for CTF at finger/toe for the age groups 20-39 and 40-60 years were 7.4/4.9 and 5.8/4.6 s, respectively. Reference values for RSTF at finger/toe for the age groups 20-39 and 40-60 years were 6.9/5.5 and 6.2/4.7, respectively. CTF provides quantitative values that are as good as those provided by RSTF. Age-stratified reference data are provided. Muscle Nerve 57: 49-53, 2018. © 2017 Wiley Periodicals, Inc.
Determination of ferrous and total iron in refractory spinels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amonette, James E.; Matyas, Josef
2015-12-30
Accurate and precise determination of the redox state of iron (Fe) in spinels presents a significant challenge due to their refractory nature. The resultant extreme conditions needed to obtain complete dissolution generally oxidize some of the Fe(II) initially present and thus prevent the use of colorimetric methods for Fe(II) measurements. To overcome this challenge we developed a hybrid oxidimetric/colorimetric approach, using Ag(I) as the oxidimetric reagent for determination of Fe(II) and 1,10-phenanthroline as the colorimetric reagent for determination of total Fe. This approach, which allows determination of Fe(II) and total Fe on the same sample, was tested on a seriesmore » of four geochemical reference materials and then applied to the analysis of Fe(Ni) spinel crystals isolated from simulated high-level-waste (HLW) glass and of several reagent magnetites. Results for the reference materials were in excellent agreement with published values, with the exception of USGS BIR-1, for which higher Fe(II) values and lower total Fe values were obtained. The Fe(Ni) spinels showed Fe(II) values at the detection limit (ca. 0.05 wt% Fe) and total Fe values slightly higher than obtained by total elemental analysis. For the magnetite samples, total Fe values were in agreement with reference results, but a wide range in Fe(II) values was obtained indicating various degrees of conversion to maghemite.« less
Armando García-Miranda, L; Contreras, I; Estrada, J A
2014-04-01
To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Chew, Gina; Sim, Lay Peng; Ng, Sin Yee; Ding, Yi; Shin, Richard Y C; Lee, Tong Kooi
2016-01-01
Isotope dilution mass spectrometry and standard addition techniques were developed for the analysis of four elements (Ca, As, Cd and Pb) in a mushroom powder material. Results from the validated methods were compared to those of other national metrology institutes in the CCQM-K89 intercomparisons and the results were in excellent agreement with the reference values. The same methods were then used for the assignment of reference values to a mushroom powder Certified Reference Material (CRM). The certified values obtained for Ca, As, Cd and Pb were 1.444 ± 0.099 mg/g, 5.61 ± 0.59 mg/kg, 1.191 ± 0.079 mg/kg and 5.23 ± 0.94 mg/kg, respectively. The expanded measurement uncertainties were obtained by combining the uncertainty contributions from characterization (uchar) and between-bottle homogeneity (ubb). Copyright © 2015 Elsevier Ltd. All rights reserved.
Reimbursement of pharmaceuticals: reference pricing versus health technology assessment.
Drummond, Michael; Jönsson, Bengt; Rutten, Frans; Stargardt, Tom
2011-06-01
Reference pricing and health technology assessment are policies commonly applied in order to obtain more value for money from pharmaceuticals. This study focussed on decisions about the initial price and reimbursement status of innovative drugs and discussed the consequences for market access and cost. Four countries were studied: Germany, The Netherlands, Sweden and the United Kingdom. These countries have operated one, or both, of the two policies at certain points in time, sometimes in parallel. Drugs in four groups were considered: cholesterol-lowering agents, insulin analogues, biologic drugs for rheumatoid arthritis and "atypical" drugs for schizophrenia. Compared with HTA, reference pricing is a relatively blunt instrument for obtaining value for money from pharmaceuticals. Thus, its role in making reimbursement decisions should be limited to drugs which are therapeutically equivalent. HTA is a superior strategy for obtaining value for money because it addresses not only price but also the appropriate indications for the use of the drug and the relation between additional value and additional costs. However, given the relatively higher costs of conducting HTAs, the most efficient approach might be a combination of both policies.
Bedewi, Mohamed Abdelmohsen; Abodonya, Ahmed; Kotb, Mamdouh; Kamal, Sanaa; Mahmoud, Gehan; Aldossari, Khaled; Alqabbani, Abdullah; Swify, Sherine
2018-03-01
The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ± 6.9, tibial nerve at the level of the medial malleolus 12.7 mm ± 4.5, common peroneal nerve at the popliteal fossa 9.5 mm ± 4, common peroneal nerve fibular head 8.9 mm ± 3.2, sural nerve 3.5 mm ± 1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.
Han, Xiao; Ge, Miao; Dong, Jie; Xue, Ranying; Wang, Zixuan; He, Jinwei
2014-09-01
The aim of this paper is to analyze the geographical distribution of reference value of aging people's left ventricular end systolic diameter (LVDs), and to provide a scientific basis for clinical examination. The study is focus on the relationship between reference value of left ventricular end systolic diameter of aging people and 14 geographical factors, selecting 2495 samples of left ventricular end systolic diameter (LVDs) of aging people in 71 units of China, in which including 1620 men and 875 women. By using the Moran's I index to make sure the relationship between the reference values and spatial geographical factors, extracting 5 geographical factors which have significant correlation with left ventricular end systolic diameter for building the support vector regression, detecting by the method of paired sample t test to make sure the consistency between predicted and measured values, finally, makes the distribution map through the disjunctive kriging interpolation method and fits the three-dimensional trend of normal reference value. It is found that the correlation between the extracted geographical factors and the reference value of left ventricular end systolic diameter is quite significant, the 5 indexes respectively are latitude, annual mean air temperature, annual mean relative humidity, annual precipitation amount, annual range of air temperature, the predicted values and the observed ones are in good conformity, there is no significant difference at 95% degree of confidence. The overall trend of predicted values increases from west to east, increases first and then decreases from north to south. If geographical values are obtained in one region, the reference value of left ventricular end systolic diameter of aging people in this region can be obtained by using the support vector regression model. It could be more scientific to formulate the different distributions on the basis of synthesizing the physiological and the geographical factors. -Use Moran's index to analyze the spatial correlation. -Choose support vector machine to build model that overcome complexity of variables. -Test normal distribution of predicted data to guarantee the interpolation results. -Through trend analysis to explain the changes of reference value clearly. Copyright © 2014 Elsevier Inc. All rights reserved.
Hematologic and serum chemistry reference intervals for free-ranging lions (Panthera leo).
Maas, Miriam; Keet, Dewald F; Nielen, Mirjam
2013-08-01
Hematologic and serum chemistry values are used by veterinarians and wildlife researchers to assess health status and to identify abnormally high or low levels of a particular blood parameter in a target species. For free-ranging lions (Panthera leo) information about these values is scarce. In this study 7 hematologic and 11 serum biochemistry values were evaluated from 485 lions from the Kruger National Park, South Africa. Significant differences between sexes and sub-adult (≤ 36 months) and adult (>36 months) lions were found for most of the blood parameters and separate reference intervals were made for those values. The obtained reference intervals include the means of the various blood parameter values measured in captive lions, except for alkaline phosphatase in the subadult group. These reference intervals can be utilized for free-ranging lions, and may likely also be used as reference intervals for captive lions. Copyright © 2013 Elsevier Ltd. All rights reserved.
Handwriting assessment of Franco-Quebec primary school-age students
Couture, Mélanie; Morin, Marie-France; Coallier, Mélissa; Lavigne, Audrey; Archambault, Patricia; Bolduc, Émilie; Chartier, Émilie; Liard, Karolane; Jasmin, Emmanuelle
2016-12-01
Reasons for referring school-age children to occupational therapy mainly relate to handwriting problems. However, there are no validated tools or reference values for assessing handwriting in francophone children in Canada. This study aimed to adapt and validate the writing tasks described in an English Canadian handwriting assessment protocol and to develop reference values for handwriting speed for francophone children. Three writing tasks from the Handwriting Assessment Protocol-2nd Edition (near-point and far-point copying and dictation) were adapted for Québec French children and administered to 141 Grade 1 ( n = 73) and Grade 2 ( n = 68) students. Reference values for handwriting speed were obtained for near point and far point copying tasks. This adapted protocol and these reference values for speed will improve occupational therapy handwriting assessments for the target population.
Ottaway, Josh; Farrell, Jeremy A; Kalivas, John H
2013-02-05
An essential part to calibration is establishing the analyte calibration reference samples. These samples must characterize the sample matrix and measurement conditions (chemical, physical, instrumental, and environmental) of any sample to be predicted. Calibration usually requires measuring spectra for numerous reference samples in addition to determining the corresponding analyte reference values. Both tasks are typically time-consuming and costly. This paper reports on a method named pure component Tikhonov regularization (PCTR) that does not require laboratory prepared or determined reference values. Instead, an analyte pure component spectrum is used in conjunction with nonanalyte spectra for calibration. Nonanalyte spectra can be from different sources including pure component interference samples, blanks, and constant analyte samples. The approach is also applicable to calibration maintenance when the analyte pure component spectrum is measured in one set of conditions and nonanalyte spectra are measured in new conditions. The PCTR method balances the trade-offs between calibration model shrinkage and the degree of orthogonality to the nonanalyte content (model direction) in order to obtain accurate predictions. Using visible and near-infrared (NIR) spectral data sets, the PCTR results are comparable to those obtained using ridge regression (RR) with reference calibration sets. The flexibility of PCTR also allows including reference samples if such samples are available.
Experimental validation of beam quality correction factors for proton beams
NASA Astrophysics Data System (ADS)
Gomà, Carles; Hofstetter-Boillat, Bénédicte; Safai, Sairos; Vörös, Sándor
2015-04-01
This paper presents a method to experimentally validate the beam quality correction factors (kQ) tabulated in IAEA TRS-398 for proton beams and to determine the kQ of non-tabulated ionization chambers (based on the already tabulated values). The method is based exclusively on ionometry and it consists in comparing the reading of two ionization chambers under the same reference conditions in a proton beam quality Q and a reference beam quality 60Co. This allows one to experimentally determine the ratio between the kQ of the two ionization chambers. In this work, 7 different ionization chamber models were irradiated under the IAEA TRS-398 reference conditions for 60Co beams and proton beams. For the latter, the reference conditions for both modulated beams (spread-out Bragg peak field) and monoenergetic beams (pseudo-monoenergetic field) were studied. For monoenergetic beams, it was found that the experimental kQ values obtained for plane-parallel chambers are consistent with the values tabulated in IAEA TRS-398; whereas the kQ values obtained for cylindrical chambers are not consistent—being higher than the tabulated values. These results support the suggestion (of previous publications) that the IAEA TRS-398 reference conditions for monoenergetic proton beams should be revised so that the effective point of measurement of cylindrical ionization chambers is taken into account when positioning the reference point of the chamber at the reference depth. For modulated proton beams, the tabulated kQ values of all the ionization chambers studied in this work were found to be consistent with each other—except for the IBA FC65-G, whose experimental kQ value was found to be 0.6% lower than the tabulated one. The kQ of the PTW Advanced Markus chamber, which is not tabulated in IAEA TRS-398, was found to be 0.997 ± 0.042 (k = 2), based on the tabulated value of the PTW Markus chamber.
WHO Melting-Point Reference Substances
Bervenmark, H.; Diding, N. Å.; Öhrner, B.
1963-01-01
Batches of 13 highly purified chemicals, intended for use as reference substances in the calibration of apparatus for melting-point determinations, have been subjected to a collaborative assay by 15 laboratories in 13 countries. All the laboratories performed melting-point determinations by the capillary methods described in the proposed text for the second edition of the Pharmacopoea Internationalis and some, in addition, carried out determinations by the microscope hot stage (Kofler) method, using both the “going-through” and the “equilibrium” technique. Statistical analysis of the data obtained by the capillary method showed that the within-laboratory variation was small and that the between-laboratory variation, though constituting the greatest part of the whole variance, was not such as to warrant the exclusion of any laboratory from the evaluation of the results. The average values of the melting-points obtained by the laboratories can therefore be used as constants for the substances in question, which have accordingly been established as WHO Melting-Point Reference Substances and included in the WHO collection of authentic chemical substances. As to the microscope hot stage method, analysis of the results indicated that the values obtained by the “going-through” technique did not differ significantly from those obtained by the capillary method, but the values obtained by the “equilibrium” technique were mostly significantly lower. PMID:20604137
Imboden, Mary T; Welch, Whitney A; Swartz, Ann M; Montoye, Alexander H K; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A
2017-01-01
Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesity-related health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10-year age groups. Women had higher (p<0.01) mean %BF and FMI than men, whereas men had higher (p<0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women. These reference values provide clinicians and researchers with a resource for interpretation of DXA-derived fat mass measurements specific to use with GE-Healthcare DXA systems.
Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.
Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T
2017-12-01
The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.
Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey
2011-06-01
Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (p<0.001). Newborns through vaginal delivery had significantly higher RBC count, Hb, hematocrit, platelet count, and WBC count (p<0.001). The percentages of some different types WBC were significantly influenced by gender and delivery routes. Male babies had higher lymphocyte, monocyte, eosinophil, basophil, and nucleated RBC ratios than the female neonates. Newborns through cesarean section had significantly lower neutrophil, monocyte, and nucleated RBC ratios, but higher lymphocyte and eosinophil ratios, than newborns through vaginal delivery. We successfully obtained the normal CBC and WBC DC reference values of the cord blood in Taiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.
Statistical considerations for harmonization of the global multicenter study on reference values.
Ichihara, Kiyoshi
2014-05-15
The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.
Determination of iodine in bread and fish using the iodide ion-selective electrode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steiner, J.B.
The purpose of this study was to assess the potential for use of the ion-selective electrode (ISE) as a method for measuring the iodine content in bread and fish. Ashing methods, sample preparation and electrode responses were evaluated. The iodine values obtained using the iodide electrode were compared to iodine values obtained by the arsenic-cerium method (As-Ce). Ashing methods were used in preparing bread and haddock for iodine analysis by the ISE. The values were compared to unashed samples measured by the ISE. Electrode response to iodide was examined by varying the sample pH, measuring electrode equilibrium times, and comparingmore » direct measurement in ppm to iodide values obtained by the method of known addition. Oyster reference tissue with a known iodine concentration was used to determine rates of recovery. For the As-Ce procedure, an alkaline dry ash for two hour followed by colorimetric analysis at 320 nm was recommended. The study showed that the pre-treatment of bread and fish was necessary for ISE measurement. The iodine values obtained by the ISE in the analysis of oyster reference tissue, haddock and bread were not in agreement with their corresponding As-Ce values. Further work needs to be done to determine an ashing procedure that has minimal iodide loss an/or develop sample treatments that will improve the reliability and precision of iodine values obtained using the ion-selective electrode.« less
NASA Astrophysics Data System (ADS)
Gang, Zhang; Fansong, Meng; Jianzhong, Wang; Mingtao, Ding
2018-02-01
Determining magnetotelluric impedance precisely and accurately is fundamental to valid inversion and geological interpretation. This study aims to determine the minimum value of signal-to-noise ratio (SNR) which maintains the effectiveness of remote reference technique. Results of standard time series simulation, addition of different Gaussian noises to obtain the different SNR time series, and analysis of the intermediate data, such as polarization direction, correlation coefficient, and impedance tensor, show that when the SNR value is larger than 23.5743, the polarization direction disorder at morphology and a smooth and accurate sounding carve value can be obtained. At this condition, the correlation coefficient value of nearly complete segments between the base and remote station is larger than 0.9, and impedance tensor Zxy presents only one aggregation, which meet the natural magnetotelluric signal characteristic.
[Reference values for lead levels in blood for the urban population].
Paolielo, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Alvarenga, A L; Carvalho, S R; Figueiroa, G A; Leite, V G; Gutierrez, A C; Nogueira, K B; Inamine, W A; Zavatti, A M
1997-04-01
The lead reference values for blood used in Brazil come from studies conducted in other countries, where socioeconomic, clinical, nutritional and occupational conditions are significantly different. In order to guarantee an accurate biomonitoring of the population which is occupationally exposed to lead, a major health concern of the studied community, reference values for individuals who are not occupationally exposed and who live in the southern region of the city were established. The sample was composed of 206 subjects of at least 15 years of age. Various strategies were employed to assure good-quality sampling. Subjects who presented values outside clinical or laboratory norms were excluded, as well as those whose specific activities might interfere with the results. Lead reference values for blood were found to be from 2.40 to 16.6 micrograms.dL-1, obtained by the interval x +/- 2s (where x is the mean and s is the standard deviation form observed values) and the median was 7.9 micrograms.dL-1.
Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen
2015-08-25
To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.
Influence of echo time in quantitative proton MR spectroscopy using LCModel.
Yamamoto, Tetsuya; Isobe, Tomonori; Akutsu, Hiroyoshi; Masumoto, Tomohiko; Ando, Hiroki; Sato, Eisuke; Takada, Kenta; Anno, Izumi; Matsumura, Akira
2015-06-01
The objective of this study was to elucidate the influence on quantitative analysis using LCModel with the condition of echo time (TE) longer than the recommended values in the spectrum acquisition specifications. A 3T magnetic resonance system was used to perform proton magnetic resonance spectroscopy. The participants were 5 healthy volunteers and 11 patients with glioma. Data were collected at TE of 72, 144 and 288ms. LCModel was used to quantify several metabolites (N-acetylaspartate, creatine and phosphocreatine, and choline-containing compounds). The results were compared with quantitative values obtained by using the T2-corrected internal reference method. In healthy volunteers, when TE was long, the quantitative values obtained using LCModel were up to 6.8-fold larger (p<0.05) than those obtained using the T2-corrected internal reference method. The ratios of the quantitative values obtained by the two methods differed between metabolites (p<0.05). In patients with glioma, the ratios of quantitative values obtained by the two methods tended to be larger at longer TE, similarly to the case of healthy volunteers, and large between-individual variation in the ratios was observed. In clinical practice, TE is sometimes set longer than the value recommended for LCModel. If TE is long, LCModel overestimates the quantitative value since it cannot compensate for signal attenuation, and this effect is different for each metabolite and condition. Therefore, if TE is longer than recommended, it is necessary to account for the possibly reduced reliability of quantitative values calculated using LCModel. Copyright © 2015 Elsevier Inc. All rights reserved.
Perich, C; Ricós, C; Alvarez, V; Biosca, C; Boned, B; Cava, F; Doménech, M V; Fernández-Calle, P; Fernández-Fernández, P; García-Lario, J V; Minchinela, J; Simón, M; Jansen, R
2014-05-15
Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods). The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide. Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation. Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results. Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Age- and sex-specific reference values of a test of neck muscle endurance.
Peolsson, Anneli; Almkvist, Cecilia; Dahlberg, Camilla; Lindqvist, Sara; Pettersson, Susanne
2007-01-01
This study evaluates age- and sex-specific reference values for neck muscle endurance (NME). In this cross-sectional study, 116 randomly selected, healthy volunteers (ages 25-64 years) stratified according to age and gender participated. Dorsal and ventral NME was measured in seconds until exhaustion in a laying-down position. A weight of 4 kg for men or 2 kg for women was used in the dorsal procedure. The ventral procedure was performed without external load. Background and physical activity data were obtained and used in the analysis of NME performance. Mean values for dorsal and ventral NME were about 7 and 2.5 minutes for men and 8.5 and 0.5 minutes for women, respectively. The cutoff values for subnormal dorsal and ventral NME were 157 and 56 seconds for men and 173 and 23 seconds for women, respectively. Women's NME was 122% of men's NME in the dorsal (P = .17) and 24% of men's NME in the ventral (P < .0001) procedure. There were no significant differences among age groups. In multiple regression analysis, physical activity explained 4% of variability in the performance of the dorsal NME; and sex explained 37% of the variability in the performance of ventral NME. The reference values and the cutoff points obtained could be used in clinical practice to identify patients with a subnormal NME. Sex is an important consideration when using both the test procedure and the reference values.
Serum free light chain reference values: a critical approach.
Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario
2013-05-01
The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.
How the reference values for serum parathyroid hormone concentration are (or should be) established?
Souberbielle, J-C; Brazier, F; Piketty, M-L; Cormier, C; Minisola, S; Cavalier, E
2017-03-01
Well-validated reference values are necessary for a correct interpretation of a serum PTH concentration. Establishing PTH reference values needs recruiting a large reference population. Exclusion criteria for this population can be defined as any situation possibly inducing an increase or a decrease in PTH concentration. As recommended in the recent guidelines on the diagnosis and management of asymptomatic primary hyperparathyroidism, PTH reference values should be established in vitamin D-replete subjects with a normal renal function with possible stratification according to various factors such as age, gender, menopausal status, body mass index, and race. A consensus about analytical/pre-analytical aspects of PTH measurement is also needed with special emphasis on the nature of the sample (plasma or serum), the time and the fasting/non-fasting status of the blood sample. Our opinion is that blood sample for PTH measurement should be obtained in the morning after an overnight fast. Furthermore, despite longer stability of the PTH molecule in EDTA plasma, we prefer serum as it allows to measure calcium, a prerequisite for a correct interpretation of a PTH concentration, on the same sample. Once a consensus is reached, we believe an important international multicentre work should be performed to recruit a very extensive reference population of apparently healthy vitamin D-replete subjects with a normal renal function in order to establish the PTH normative data. Due to the huge inter-method variability in PTH measurement, a sufficient quantity of blood sample should be obtained to allow measurement with as many PTH kits as possible.
Validating Reference Equations for Impulse Oscillometry in Healthy Mexican Children.
Gochicoa-Rangel, Laura; Del Río-Hidalgo, Rodrigo; Hernández-Ruiz, Juana; Rodríguez-Moreno, Luis; Martínez-Briseño, David; Mora-Romero, Uri; Cid-Juárez, Silvia; García-Sancho, Cecilia; Torre-Bouscoulet, Luis
2017-09-01
The impulse oscillometry system (IOS) measures the impedance (Z) of the respiratory system, but proper interpretation of its results requires adequate reference values. The objectives of this work were: (1) to validate the reference equations for the IOS published previously by our group and (2) to compare the adjustment of new available reference equations for the IOS from different countries in a sample of healthy children. Subjects were healthy 4-15-y-old children from the metropolitan area of Mexico City, who performed an IOS test. The functional IOS parameters obtained were compared with the predicted values from 12 reference equations determined in studies of different ethnic groups. The validation methods applied were: analysis of the differences between measured and predicted values for each reference equation; correlation and concordance coefficients; adjustment by Z-score values; percentage of predicted value; and the percentage of patients below the lower limit of normality or above the upper limit of normality. Of the 224 participants, 117 (52.3%) were girls, and the mean age was 8.6 ± 2.3 y. The equations that showed the best adjustment for the different parameters were those from the studies by Nowowiejska et al (2008) and Gochicoa et al (2015). The equations proposed by Frei et al (2005), Hellinckx et al (1998), Kalhoff et al (2011), Klug and Bisgaard (1998), de Assumpção et al (2016), and Dencker et al (2006) overestimated the airway resistance of the children in our sample, whereas the equation of Amra et al (2008) underestimated it. In the analysis of the lower and upper limits of normality, Gochicoa et al equation was the closest, since 5% of subjects were below or above percentiles 5 and 95, respectively. The study found that, in general, all of the equations showed greater error at the extremes of the age distribution. Because of the robust adjustment of the present study reference equations for the IOS, it can be recommended for both clinical and research purposes in our population. The differential adjustment of other equations underlines the need to obtain local reference values. Copyright © 2017 by Daedalus Enterprises.
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Eleftherakis, Dimitrios; Berger, Laurent; Le Bouffant, Naig; Pacault, Anne; Augustin, Jean-Marie; Lurton, Xavier
2018-06-01
The calibration of multibeam echosounders for backscatter measurements can be conducted efficiently and accurately using data from surveys over a reference natural area, implying appropriate measurements of the local absolute values of backscatter. Such a shallow area (20-m mean depth) has been defined and qualified in the Bay of Brest (France), and chosen as a reference area for multibeam systems operating at 200 and 300 kHz. The absolute reflectivity over the area was measured using a calibrated single-beam fishery echosounder (Simrad EK60) tilted at incidence angles varying between 0° and 60° with a step of 3°. This reference backscatter level is then compared to the average backscatter values obtained by a multibeam echosounder (here a Kongsberg EM 2040-D) at a close frequency and measured as a function of angle; the difference gives the angular bias applicable to the multibeam system for recorded level calibration. The method is validated by checking the single- and multibeam data obtained on other areas with sediment types different from the reference area.
dos Santos, Sabrina Novaes; Alleoni, Luís Reynaldo Ferracciú
2013-07-01
Guideline values are used to identify polluted or contaminated areas based on background values. Brazilian law establishes three guideline values for pollutants: a quality reference value (QRV), a prevention value, and an intervention value. Reference values refer to the natural concentration of an element or a substance in soils that have not been modified by anthropogenic impacts. These values inform assessments of soil quality and are used to establish maximum permissible limits. The objective of this study was to determine the natural levels and reference values for Cd, Co, Cr, Cu, Ni, Pb, and Zn in samples from the surface layer (0-20 cm) of 19 representative soils of the states of Mato Grosso and Rondônia, on Brazil's agricultural frontier. Pseudo-total metal concentrations were obtained following microwave-assisted digestion using the aqua regia and EPA3051 methods. QRVs were calculated for each element as the 75th and 90th percentiles of the frequency distribution of the data. Natural levels of heavy metals in the soil samples followed the order: Cr > Zn > Cu > Co > Pb > Ni > and Cd (aqua regia) and Cr > Co > Cu > Pb > Zn > Ni > Cd (EPA3051). These values are generally lower than those reported in the Brazilian and international literature, which highlights the importance of establishing reference values for each state or for each soil type, taking into account the geomorphological, pedological, and geological diversity of the region under study.
Simpson, Christine A; Cusano, Anna Maria; Bihuniak, Jessica; Walker, Joanne; Insogna, Karl L
2015-04-01
The Vitamin D Standardization Program (VDSP) has identified ID-LC/MS/MS as the reference method procedure (RMP) for 25(OH) vitamin D and NIST Standard SRM2972 as the standard reference material (SRM). As manufacturers align their products to the RMP and NIST standard, a concern is that results obtained in aligned assays will be divergent from those obtained with pre-alignment assays. The Immunodiagnostic Systems Ltd., chemiluminescent, 25(OH) vitamin D iSYS platform assay, was recently harmonized to the RMP. To determine the impact of standardization on results obtained with iSYS reagents, 119 single donor serum samples from eight different disease categories were analyzed in four non-standardized and two standardized iSYS assays. There were strong correlations between the four non-standardized and two standardized assays with Spearman's rank r values between 0.975 and 0.961 and four of the eight r values were >0.97. R(2) values for the eight best-fit linear regression equations ranging between 0.947 and 0.916. None of the slopes were found to be significantly different from one another. Bland-Altman plots showed that the bias was comparable when each of the four non-standardized assays was compared to either of the standardized assays. When the data were segregated in values between 6 and 49ng/mL (15-122nmol/L) or between 50 and 100ng/mL (125-250nmol/L) significant associations remained between results obtained with non-standardized and standardized calibrators regardless of the absolute value. When five recent DEQAS unknowns were analyzed in one non-standardized and one standardized assay the mean percent difference from the NIST target in values obtained using standardized vs. non-standardized calibrators were not significantly different. Finally, strong and statistically significant associations between the results were obtained using non-standardized and standardized assays for six of eight clinical conditions. The only exceptions were hypocalcemia and breast cancer, which likely reflect the small sample sizes for each of these diseases. These initial data provide confidence that the move to a NIST standardized assay will have little impact on results obtained with the iSYS platform. This article is part of a Special Issue entitled '17th Vitamin D Workshop'. Copyright © 2014 Elsevier Ltd. All rights reserved.
Linear FBG Temperature Sensor Interrogation with Fabry-Perot ITU Multi-wavelength Reference.
Park, Hyoung-Jun; Song, Minho
2008-10-29
The equidistantly spaced multi-passbands of a Fabry-Perot ITU filter are used as an efficient multi-wavelength reference for fiber Bragg grating sensor demodulation. To compensate for the nonlinear wavelength tuning effect in the FBG sensor demodulator, a polynomial fitting algorithm was applied to the temporal peaks of the wavelength-scanned ITU filter. The fitted wavelength values are assigned to the peak locations of the FBG sensor reflections, obtaining constant accuracy, regardless of the wavelength scan range and frequency. A linearity error of about 0.18% against a reference thermocouple thermometer was obtained with the suggested method.
Li, Meng-Jiao; Ge, Miao; Wang, Cong-Xia; Cen, Min-Yi; Jiang, Ji-Lin; He, Jin-Wei; Lin, Qian-Yi; Liu, Xin
2016-08-20
To analyze the relationship between the reference values of fibrinogen (FIB) in healthy Chinese adults and geographical factors to provide scientific evidences for establishing the uniform standard. The reference values of FIB of 10701 Chinese healthy adults from 103 cities were collected to investigate their relationship with 18 geographical factors including spatial index, terrain index, climate index, and soil index. Geographical factors that significantly correlated with the reference values were selected for constructing the BP neural network model. The spatial distribution map of the reference value of FIB of healthy Chinese adults was fitted by disjunctive kriging interpolation. We used the 5-layer neural network and selected 2000 times of training covering 11 hidden layers to build the simulation rule for simulating the relationship between FIB and geographical environmental factors using the MATLAB software. s The reference value of FIB in healthy Chinese adults was significantly correlated with the latitude, sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual range of air temperature, average annual soil gravel content, and soil cation exchange capacity (silt). The artificial neural networks were created to analyze the simulation of the selected indicators of geographical factors. The spatial distribution map of the reference values of FIB in healthy Chinese adults showed a distribution pattern that FIB levels were higher in the South and lower in the North, and higher in the East and lower in the West. When the geographical factors of a certain area are known, the reference values of FIB in healthy Chinese adults can be obtained by establishing the neural network mode or plotting the spatial distribution map.
Neves, Laura A; Rodrigues, Janaína M; Daroda, Romeu J; Silva, Paulo R M; Ferreira, Alexandre A; Aranda, Donato A G; Eberlin, Marcos N; Fasciotti, Maíra
2015-11-15
Brazil is the largest producer of sugar cane bioethanol in the world. Isotope ratio mass spectrometry (IRMS) is the technique of choice to certify the origin/raw materials for ethanol production, but the lack of certified reference materials (CRMs) for accurate measurements of δ(13) C values traceable to Vienna Pee Dee Belemnite (VPDB), the international zero point for (13) C/(12) C measurements, certified and compatible with gas chromatography (GC)/IRMS instruments may compromise the accuracy of δ(13) C determinations. We evaluated the influence of methods for the calibration and normalization of raw δ(13) C values of ethanol samples. Samples were analyzed by GC/C/IRMS using two different GC columns. Different substances were used as isotopic standards for the working gas calibration. The δ(13) C values obtained with the three methods of normalization were statistically compared with those obtained with elemental analyzer (EA)/IRMS, since the δ(13) C results obtained using EA are traceable to VPDB via the NBS 22 reference material. It was observed that both the isotopic reference material for CO2 calibration and the GC column have a major effect on the δ(13) C measurements, leading to a bias of almost 2-3 ‰ in the δ(13) C values. All three methods of normalization were equivalent in performance, enabling an improvement in the GC/C/IRMS accuracy, compared with the EA/IRMS reference values for the samples. All the methods of CO2 calibration, chromatography and normalization presented in this work demonstrated several sources of traceability and accuracy loss for the determination of δ(13) C values in ethanol fuel samples by GC/C/IRMS. This work has also shown the importance of using proper CRMs traceable to VPBD that should be compatible and certified using GC/C/IRMS, ideally in a wide range of δ(13) C values. This is important not only for bioethanol fuel samples, but also for many analytes commonly analyzed by IRMS. Copyright © 2015 John Wiley & Sons, Ltd.
Sonawane, A U; Shirva, V K; Pradhan, A S
2010-02-01
Skin entrance doses (SEDs) were estimated by carrying out measurements of air kerma from 101 X-ray machines installed in 45 major and selected hospitals in the country by using a silicon detector-based dose Test-O-Meter. 1209 number of air kerma measurements of diagnostic projections for adults have been analysed for seven types of common diagnostic examinations, viz. chest (AP, PA, LAT), lumbar spine (AP, LAT), thoracic spine (AP, LAT), abdomen (AP), pelvis (AP), hip joints (AP) and skull (PA, LAT) for different film-screen combinations. The values of estimated diagnostic reference levels (DRLs) (third quartile values of SEDs) were compared with guidance levels/DRLs of doses published by the IAEA-BSS-Safety Series No. 115, 1996; HPA (NRPB) (2000 and 2005), UK; CRCPD/CDRH (USA), European Commission and other national values. The values of DRLs obtained in this study are comparable with the values published by the IAEA-BSS-115 (1996); HPA (NRPB) (2000 and 2005) UK; EC and CRCPD/CDRH, USA including values obtained in previous studies in India.
Preparation of canine C-reactive protein serum reference material: A feasibility study.
Canalias, Francesca; Piñeiro, Matilde; Pato, Raquel; Peña, Raquel; Bosch, Lluís; Soler, Lourdes; García, Natalia; Lampreave, Fermín; Saco, Yolanda; Bassols, Anna
2018-03-01
The availability of a species-specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. We describe the preparation of a canine C-reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Canine C-reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings. © 2018 American Society for Veterinary Clinical Pathology.
Ning, Lei; Song, Li-Jiang; Fan, Shun-Wu; Zhao, Xing; Chen, Yi-Lei; Li, Zhao-Zhi; Hu, Zi-Ang
2017-10-11
This study established gender-specific reference values in mainland Chinese (MC) and is important for quantitative morphometry for diagnosis and epidemiological study of osteoporotic vertebral compressive fracture. Comparisons of reference values among different racial populations are then performed to demonstrate the MC-specific characteristic. Osteoporotic vertebral compressive fracture (OVCF) is a common complication of osteoporosis in the elder population. Clinical diagnosis and epidemiological study of OVCF often employ quantitative morphometry, which relies heavily on the comparison of patients' vertebral parameters to existing reference values derived from the normal population. Thus, reference values are crucial in clinical diagnosis. To our knowledge, this is the first study to establish reference values of the mainland Chinese (MC) for quantitative morphometry. Vertebral heights including anterior (Ha), middle (Hm), posterior (Hp) heights, and predicted posterior height (pp) from T4 to L5 were obtained; and ratios of Ha/Hp, Hm/Hp and Hp/pp. were calculated from 585 MC (both female and male) for establishing reference values and subsequent comparisons with other studies. Vertebral heights increased progressively from T4 to L3 but then decreased in L4 and L5. Both genders showed similar ratios of vertebral dimensions, but male vertebrae were statistically larger than those of female (P < 0.01). Vertebral size of MC population was smaller than that of US and UK population, but was surprisingly larger than that of Hong Kong Chinese, although these two are commonly considered as one race. Data from different racial populations showed similar dimensional ratios in all vertebrae. We established gender-specific reference values for MC. Our results also indicated the necessity of establishing reference values that are not only race- and gender-specific, but also population- or region-specific for accurate quantitative morphometric assessment of OVCF.
Choice of Reference Serum Creatinine in Defining AKI
Siew, Edward D.; Matheny, Michael E.
2015-01-01
Background/Aims The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. Methods We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating estimation of baseline renal function, using Pubmed and reference back-tracing within known works. Results 1) Prehospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, 2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations 3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, 4) using more specific definitions of AKI (e.g. KIDGO Stage 2 and 3) may help to reduce the effects of misclassification when using surrogate values, and 5) leveraging available clinical data may help refine the estimate of reference creatinine. Conclusions Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. PMID:26332325
Torén, Kjell; Murgia, Nicola; Schiöler, Linus; Bake, Björn; Olin, Anna-Carin
2017-08-25
Fractional exhaled nitric oxide (FE NO ) is used to assess of airway inflammation; diagnose asthma and monitor adherence to advised therapy. Reliable and accurate reference values for FE NO are needed for both non-smoking and current smoking adults in the clinical setting. The present study was performed to establish reference adult FE NO values among never-smokers, former smokers and current smokers. FE NO was measured in 5265 subjects aged 25-75 years in a general-population study, using a chemiluminescence (Niox ™) analyser according to the guidelines of the American Thoracic Society and the European Respiratory Society. Atopy was based on the presence of immunoglobulin E (IgE) antibodies to common inhalant allergens (measured using Phadiatop® test). Spirometry without bronchodilation was performed and forced vital capacity (FVC), forced expired volume in 1 s (FEV 1 ) and the ratio of FEV 1 to FVC values were obtained. After excluding subjects with asthma, chronic bronchitis, spirometric airway obstruction and current cold, 3378 subjects remained. Equations for predictions of FE NO values were modelled using nonparametric regression models. FE NO levels were similar in never-smokers and former smokers, and these two groups were therefore merged into a group termed "non-smokers". Reference equations, including the 5th and 95th percentiles, were generated for female and male non-smokers, based on age, height and atopy. Regression models for current smokers were unstable. Hence, the proposed reference values for current smokers are based on the univariate distribution of FE NO and fixed cut-off limits. Reference values for FE NO among respiratory healthy non-smokers should be outlined stratified for gender using individual reference values. For current smokers separate cut-off limits are proposed.
Linear FBG Temperature Sensor Interrogation with Fabry-Perot ITU Multi-wavelength Reference
Park, Hyoung-Jun; Song, Minho
2008-01-01
The equidistantly spaced multi-passbands of a Fabry-Perot ITU filter are used as an efficient multi-wavelength reference for fiber Bragg grating sensor demodulation. To compensate for the nonlinear wavelength tuning effect in the FBG sensor demodulator, a polynomial fitting algorithm was applied to the temporal peaks of the wavelength-scanned ITU filter. The fitted wavelength values are assigned to the peak locations of the FBG sensor reflections, obtaining constant accuracy, regardless of the wavelength scan range and frequency. A linearity error of about 0.18% against a reference thermocouple thermometer was obtained with the suggested method. PMID:27873898
Suzuki, Satoru; Midorikawa, Sanae; Fukushima, Toshihiko; Shimura, Hiroki; Ohira, Tetsuya; Ohtsuru, Akira; Abe, Masafumi; Shibata, Yoshisada; Yamashita, Shunichi; Suzuki, Shinichi
2015-01-01
Although several reports have defined normal thyroid volume depending on either age or body surface, there are no sequential reference values on childhood thyroid volume evaluated by using ultrasonography and epidemiological analysis in Japan. The aim of the present study was to establish updated reference values for thyroid volume by ultrasound examination and epidemiological analysis in 0-19 year-old Japanese children. It is based on a cross-sectional study conducted from October 9, 2011 to March 31, 2012. The subjects were 38,063 children who were examined by ultrasonography as the initial preliminary survey of the Fukushima Health Management Survey in October 9, 2011 to March 31, 2012. The width, thickness, and height of each lobe were measured and the volume of each lobe was calculated by the mean of the elliptical shape volume formula. The values of thyroid volume at the 2.5 and 97.5 percentiles of age and body surface area for each gender group were obtained from 0-19 year-old children. Positive correlation was observed between thyroid volume and either age or body surface. The right lobe was significantly larger than the left lobe. The thyroid volume in females was larger than that in males after adjusting body surface area. The reference values of childhood thyroid for each age or body surface area were obtained by this extensive survey using ultrasound. These reference values may be used to define the normal size of thyroid gland by echosonography in Japanese children, although thyroid volume may be affected by dimorphic factors such as sex hormones.
General Analytical Procedure for Determination of Acidity Parameters of Weak Acids and Bases
Pilarski, Bogusław; Kaliszan, Roman; Wyrzykowski, Dariusz; Młodzianowski, Janusz; Balińska, Agata
2015-01-01
The paper presents a new convenient, inexpensive, and reagent-saving general methodology for the determination of pK a values for components of the mixture of diverse chemical classes weak organic acids and bases in water solution, without the need to separate individual analytes. The data obtained from simple pH-metric microtitrations are numerically processed into reliable pK a values for each component of the mixture. Excellent agreement has been obtained between the determined pK a values and the reference literature data for compounds studied. PMID:25692072
General analytical procedure for determination of acidity parameters of weak acids and bases.
Pilarski, Bogusław; Kaliszan, Roman; Wyrzykowski, Dariusz; Młodzianowski, Janusz; Balińska, Agata
2015-01-01
The paper presents a new convenient, inexpensive, and reagent-saving general methodology for the determination of pK a values for components of the mixture of diverse chemical classes weak organic acids and bases in water solution, without the need to separate individual analytes. The data obtained from simple pH-metric microtitrations are numerically processed into reliable pK a values for each component of the mixture. Excellent agreement has been obtained between the determined pK a values and the reference literature data for compounds studied.
SCUD: fast structure clustering of decoys using reference state to remove overall rotation.
Li, Hongzhi; Zhou, Yaoqi
2005-08-01
We developed a method for fast decoy clustering by using reference root-mean-squared distance (rRMSD) rather than commonly used pairwise RMSD (pRMSD) values. For 41 proteins with 2000 decoys each, the computing efficiency increases nine times without a significant change in the accuracy of near-native selections. Tests on additional protein decoys based on different reference conformations confirmed this result. Further analysis indicates that the pRMSD and rRMSD values are highly correlated (with an average correlation coefficient of 0.82) and the clusters obtained from pRMSD and rRMSD values are highly similar (the representative structures of the top five largest clusters from the two methods are 74% identical). SCUD (Structure ClUstering of Decoys) with an automatic cutoff value is available at http://theory.med.buffalo.edu. (c) 2005 Wiley Periodicals, Inc.
Lemaillet, Paul; Bouchard, Jean-Pierre; Allen, David W
2015-07-01
The development of a national reference instrument dedicated to the measurement of the scattering and absorption properties of solid tissue-mimicking phantoms used as reference standards is presented. The optical properties of the phantoms are measured with a double-integrating sphere setup in the steady-state domain, coupled with an inversion routine of the adding-doubling procedure that allows for the computation of the uncertainty budget for the measurements. The results are compared to the phantom manufacturer's values obtained by a time-resolved approach. The results suggest that the agreement between these two independent methods is within the estimated uncertainties. This new reference instrument will provide optical biomedical research laboratories with reference values for absolute diffuse optical properties of phantom materials.
Steinmetz, Josiane; Schiele, Françoise; Gueguen, René; Férard, Georges; Henny, Joseph
2007-01-01
The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.
Kato, Megumi; Yamazaki, Taichi; Kato, Hisashi; Eyama, Sakae; Goto, Mari; Yoshioka, Mariko; Takatsu, Akiko
2015-01-01
To ensure the reliability of amino acid analyses, the National Metrology Institute of Japan of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed high-purity certified reference materials (CRMs) for 17 proteinogenic amino acids. These CRMs are intended for use as primary reference materials to enable the traceable quantification of amino acids. The purity of the present CRMs was determined based on two traceable methods: nonaqueous acidimetric titration and nitrogen determination by the Kjeldahl method. Since neither method could distinguish compounds with similar structures, such as amino acid-related impurities, impurities were thoroughly quantified by combining several HPLC methods, and subtracted from the obtained purity of each method. The property value of each amino acid was calculated as a weighted mean of the corrected purities by the two methods. The uncertainty of the property value was obtained by combining measurement uncertainties of the two methods, a difference between the two methods, the uncertainty from the contribution of impurities, and the uncertainty derived from inhomogeneity. The uncertainty derived from instability was considered to be negligible based on stability monitoring of some CRMs. The certified value of each amino acid, property value with uncertainty, was given for both with or without enantiomeric separation.
Study of extremely low frequency electromagnetic fields in infant incubators.
Cermáková, Eleonora
2003-01-01
The aim of the work was to present the results of measurements of extremely low frequency electromagnetic fields (ELF EMF), namely the magnetic flux density, inside infant incubators, and to compare these results with the data published by other authors who point out to a possible association between leukemia or other diseases observed in newborns kept in incubators after the birth and the ELF EMF exposure in the incubator. The measured magnetic flux densities were compared with the reference values for this frequency range indicated in the European Union (EU) recommendations. The repeated measurements in incubators were made with a calibrated magnetometer EFA 300 in the frequency range of 5-30 kHz. Effective values of magnetic flux densities of ELF EMF were determined taking account of the reference values. The results of many repeated measurements showing the values of magnetic flux density in modern incubators with plastic supporting frame, were compared with those obtained in old type incubators with iron skeleton. A power frequency of 50 Hz was detected in the incubator and the ELF EMF values were by over two orders lower than the EU reference values. The paper emphasizes the need to take a special care of newborns kept in incubators even if only the sub-reference values are detected. The EU reference values are intended for the adult human population. A baby in an incubator has much smaller dimensions, higher electric conductivity and maybe trigger another mechanism of response to ELF EMF than that indicated in this paper.
Martínez Fernández, G; Ortega Cerrato, A; Masiá Mondéjar, J; Pérez Rodríguez, A; Llamas Fuentes, F; Gómez Roldán, C; Pérez-Martínez, Juan
2013-04-01
To calculate Kt/V, volume (V) is usually obtained by Watson formula, but bioimpedance spectroscopy (BIS) is a simple and applicable technique to determinate V, along with other hydration and nutrition parameters, in peritoneal dialysis (PD) patients. Dialysis efficacy can also be measured with Kt, but no experience exists in PD, so there is no reference/target value for Kt that must be achieved in these patients to be considered adequately dialyzed. We evaluated the efficacy of PD with Kt/V using Watson formula and BIS for V calculation, assessed hydration status in a PD unit by data obtained by BIS, and attempted to find a reference Kt from the Kt/V previously obtained by BIS. In this observational prospective study of 78 PD patients, we measured V using BIS (V bis) and Watson formula (V w) and calculated weekly Kt/V using both volumes (Kt/V bis/V bis and Kt/V w). With the BIS technique, we obtained and subsequently analyzed other hydration status parameters. We achieved a reference Kt, extrapolating the value desired (weekly Kt/V 1.7) to the target Kt using the simple linear regression statistical technique, basing it on the results of the previously calculated Pearson's linear correlation coefficient. Volume was 1.8 l higher by Watson formula than with BIS (p < 0.001). Weekly Kt/V bis was 2.33 ± 0.68, and mean weekly Kt/V w was 2.20 ± 0.63 (p < 0.0001); 60.25 % of patients presented overhydration according to the BIS study (OH >1.1 l). The target value of Kt for the reference weekly Kt/V bis (1.7) was 64.87 l. BIS is a simple, applicable technique for calculating V in dialysis that can be especially useful in PD patients compared with the anthropometric formulas, by the abnormally distributed body water in these patients. Other parameters obtained by BIS will serve to assess both the distribution of body volume and nutritional status in the clinical setting. The target Kt value obtained from Kt/V bis allowed us to measure the efficacy of PD in a practical way, omitting V measurement.
2012-01-01
Background Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established. Results As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Saanen goats. Conclusions PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research. PMID:23067875
Varrone, Andrea; Gulyás, Balázs; Takano, Akihiro; Stabin, Michael G; Jonsson, Cathrine; Halldin, Christer
2012-02-01
[(18)F]FE-PE2I is a promising dopamine transporter (DAT) radioligand. In nonhuman primates, we examined the accuracy of simplified quantification methods and the estimates of radiation dose of [(18)F]FE-PE2I. In the quantification study, binding potential (BP(ND)) values previously reported in three rhesus monkeys using kinetic and graphical analyses of [(18)F]FE-PE2I were used for comparison. BP(ND) using the cerebellum as reference region was obtained with four reference tissue methods applied to the [(18)F]FE-PE2I data that were compared with the kinetic and graphical analyses. In the whole-body study, estimates of adsorbed radiation were obtained in two cynomolgus monkeys. All reference tissue methods provided BP(ND) values within 5% of the values obtained with the kinetic and graphical analyses. The shortest imaging time for stable BP(ND) estimation was 54 min. The average effective dose of [(18)F]FE-PE2I was 0.021 mSv/MBq, similar to 2-deoxy-2-[(18)F]fluoro-d-glucose. The results in nonhuman primates suggest that [(18)F]FE-PE2I is suitable for accurate and stable DAT quantification, and its radiation dose estimates would allow for a maximal administered radioactivity of 476 MBq in human subjects. Copyright © 2012 Elsevier Inc. All rights reserved.
A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.
McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M
2018-04-01
Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p < 0.000). Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p < 0.000). When categorizing CPP as binary endpoint, 18.8% of values were identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.
Population based haematology reference ranges for old people in rural South-West Uganda.
Mugisha, Joseph O; Seeley, Janet; Kuper, Hannah
2016-09-07
Haematology reference values are needed to interpret haematology results and make clinical decisions, but these have not been established for old people in sub-Saharan Africa. The objective of this study was to establish haematology reference values for people aged 50 years and above in Uganda, to compare the haematology reference values for those aged 65 years and over with those less than 65 years and to compare these haematology reference values with established haematology reference values for old people from high income countries. A total of 1449 people aged 50 years and above were recruited from the Medical Research Council/Uganda Virus Research Institute general population cohort between January 2012 and January 2013 (response rate 72.3 %). From the blood samples collected, we did haematology, HIV testing and malaria tests. We also obtained stool samples and tested them for hookworm infection. Questionnaire data were obtained through interviews. In the analysis, we excluded those with HIV infection, malaria infection, hookworm infection and those not feeling well at the time of recruitment. Medians and reference ranges for 12 haematology parameters were determined, based on the Clinical Laboratory and Standards institute's guidelines. In total, 903 people aged 50 years and above were included in the analysis with the majority 545 (60.3 %) being female. Men had significant difference in median haemoglobin, haematocrit, erythrocytes counts and white blood cells counts, which were higher than those of women. Women had significant difference in mean platelet counts and neutrophil percentages which were higher than those of men. Comparing those aged 65+ and those aged less than 65 years, the following parameters were significantly lower in those aged above 65 years: haemoglobin, haematocrit, erythrocytes counts, platelets and mean corpuscular volume. Compared to the reference intervals from old people in high income countries, all the haematology parameters from our study population were low. The differences between haematology reference ranges in old people compared to adults and the very old (65+) compared to those between 50 and 65 call for more population based studies using nationwide surveys to be carried out among old people in other study settings in Uganda and the rest of Africa to explore the differences in haematology reference ranges between these different age groups with a view of establishing whether there is need to have separate reference range for these different categories of old people.
Glycaemic index and glycaemic load values of commonly consumed foods in the United Arab Emirates.
Al Dhaheri, Ayesha S; Henry, C Jeyakumar K; Mohamad, Maysm N; Ohuma, Eric O; Ismail, Leila Cheikh; Al Meqbaali, Fatima T; Jarrar, Amjad H
2017-04-01
Glycaemic index (GI) and glycaemic load (GL) values of some commonly consumed foods in the United Arab Emirates were determined with an aim of adding these values to the existing international table of GI and GL values. In all, eighteen test foods categorised into breads (n 5), entrée dishes (n 3), main dishes (n 5) and sweet dishes (n 5) were tested. For each test food, at least fifteen healthy participants consumed 25 or 50 g available carbohydrate portions of a reference food (glucose), which was tested three times, and a test food after an overnight fast, was tested once, on separate occasions. Capillary blood samples were obtained by finger-prick and blood glucose was measured using clinical chemistry analyser. A fasting blood sample was obtained at baseline and before consumption of test foods. Additional blood samples were obtained at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI value of each test food was calculated as the percentage of the incremental area under the blood glucose curve (IAUC) for the test food of each participant divided by the average IAUC for the reference food of the same participant. The GI values of tested foods ranged from low (55 or less) to high (70 or more). The GI values of various breads and rice-containing dishes were comparable with previously published values. This study provides GI and GL values of previously untested traditional Emirati foods which could provide a useful guide on dietary recommendations for the Emirati population.
Energy performance indicators of wastewater treatment: a field study with 17 Portuguese plants.
Silva, Catarina; Rosa, Maria João
2015-01-01
The energy costs usually represent the second largest part of the running costs of a wastewater treatment plant (WWTP). It is therefore crucial to increase the energy efficiency of these infrastructures and to implement energy management systems, where quantitative performance metrics, such as performance indicators (PIs), play a key role. This paper presents energy PIs which cover the unit energy consumption, production, net use from external sources and costs, and the results used to validate them and derive their reference values. The results of a field study with 17 Portuguese WWTPs (5-year period) were consistent with the results obtained through an international literature survey on the two key parcels of the energy balance--consumption and production. The unit energy consumption showed an overall inverse relation with the volume treated, and the reference values reflect this relation for trickling filters and for activated sludge systems (conventional, with coagulation/filtration (C/F) and with nitrification and C/F). The reference values of electrical energy production were derived from the methane generation potential (converted to electrical energy) and literature data, whereas those of energy net use were obtained by the difference between the energy consumption and production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simbeck, D.J.
1997-06-01
Reference toxicant testing using juvenile freshwater mussels was conducted as part of the CR-ERP biomonitoring study of Clinch River sediments to assess the sensitivity of test organisms and the overall performance of the test. Tests were conducted using moderately hard synthetic water spiked with known concentrations of copper as copper sulfate. Toxicity testing of copper sulfate reference toxicant was conducted from May 12-21, 1993. The organisms used for testing were juvenile fresh-water mussels (Anodonta imbecillis). Results from this test showed an LC{sub 50} value of 1.12 mg Cu/L which is lower than the value of 2.02 mg Cu/L obtained inmore » a previous test. Too few tests have been conducted with copper as the toxicant to determine a normal range of values.« less
[Reference values of proteins for the Venezuelan population].
Guerra, Marisa; Hernández, María N; López, Michelle; Alfaro, María J
2013-12-01
This study presents the reference values for protein requirements. The consumption of the Venezuelan population was obtained according to the Food Consumption Monitoring Survey (ESCA) 2010-2012. The diet provided good quality proteins, combining animal and vegetable foods in an approximate ratio of 1:1. The reference values were calculated based on the safe levels of protein intake recommended by WHO/FAO/UN 2007, with an adjustment for protein supply depending on age, weight, and contribution to the caloric formula of proteins for light physical activity. The reference values for protein requirements recommended as safe levels of intake in g/kg/day are 1.14 to 1.80 for males and females less than one-year-old, from 1 to 3 years, 0.90 to 1.14; from 4 to 6 years old, 0.86 to 0.89; and from 7 to 10 years old, 0.91 to 0.92. For adolescents, the average is 0.88 and 1.07 for males and females, respectively. In adults from 20 to 59 years old, 0.83 for men and women is recommended, and for older adults, 1.00 for men and women. In pregnant women, additional consumptions are recommended according to gestation time. Adolescent pregnant women must consume additional 1.2 to 1.7 g/kg/day to normal requirement. In breastfeeding women, the values differ between the first six months postnatal period and after six months of breastfeeding. The reference values for protein in this update were lower than the values of the 2000 version.
Dosimetry and image quality assessment in a direct radiography system
Oliveira, Bruno Beraldo; de Oliveira, Marcio Alves; Paixão, Lucas; Teixeira, Maria Helena Araújo; Nogueira, Maria do Socorro
2014-01-01
Objective To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion The present study contributes to verify the equipment conformity as regards dose values and image quality. PMID:25741119
[Study on blood pressure standard in children using the automatic sphygmomanometer].
Niida, Mami; Hataya, Hiroshi; Honda, Masataka
2015-01-01
In Japan, two treatment guidelines exist for pediatric patients with hypertension. The Guidelines for Drug Therapy in Pediatric Patients with Cardiovascular Diseases (JCS2012), by the Japanese Circulation Society, cite the stethoscopy-based American guidelines. The Guidelines for the Management of Hypertension (JSH2009), by the Japanese Society of Hypertension, focus on Japanese data obtained from automated sphygmomanometry. The frequent use of automated sphygmomanometers in clinical practice implies that the JSH2009 guidelines might be better; however with strict low reference values for the diastolic phase, overtreatment may result. Only the Japanese Circulation Society's guidelines include a therapeutic strategy, and the Chronic Kidney Disease (CKD) Guide, CKD Guidelines, and school urinary screening tests all cite these guidelines on stethoscopy-based blood pressure determination. Stethoscopy should be conducted during a medical examination; however, due to limited time in clinical practice, most physicians use automated sphygmomanometers while nevertheless relying on the Japanese Circulation Society reference values--which are stethoscopy-based. To find a compromise, we compared reference values in Japan with those from South Korea (automated sphygmomanometer-based) and those from the United States (stethoscopy-based). Moreover, we examined the results of recent accuracy tests for automated sphygmomanometers. Although the JSH2009 reference values for the systolic phase were consistent with those in the United States (stethoscopy-based), the reference values for the diastolic phase were lower. We observed the same tendency when comparing JSH2009 reference values with those in South Korea (automated sphygmomanometer-based). Conversely, there were only small differences between automated sphygmomanometry and mercury measurement, and we found it was possible to substitute the values from automated sphygmomanometry for stethoscopy. A large-scale study that takes into account patient height, measurement method, and treatment criteria is required to establish appropriate reference values. Even if automated sphygmomanometry is used until appropriate values are established, we consider the criteria provided in the American guidelines as appropriate.
Bias in estimating accuracy of a binary screening test with differential disease verification
Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.
2011-01-01
SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059
Canine and feline hematology reference values for the ADVIA 120 hematology system.
Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J
2004-01-01
The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.
Simulation studies of the fidelity of biomolecular structure ensemble recreation
NASA Astrophysics Data System (ADS)
Lätzer, Joachim; Eastwood, Michael P.; Wolynes, Peter G.
2006-12-01
We examine the ability of Bayesian methods to recreate structural ensembles for partially folded molecules from averaged data. Specifically we test the ability of various algorithms to recreate different transition state ensembles for folding proteins using a multiple replica simulation algorithm using input from "gold standard" reference ensembles that were first generated with a Gō-like Hamiltonian having nonpairwise additive terms. A set of low resolution data, which function as the "experimental" ϕ values, were first constructed from this reference ensemble. The resulting ϕ values were then treated as one would treat laboratory experimental data and were used as input in the replica reconstruction algorithm. The resulting ensembles of structures obtained by the replica algorithm were compared to the gold standard reference ensemble, from which those "data" were, in fact, obtained. It is found that for a unimodal transition state ensemble with a low barrier, the multiple replica algorithm does recreate the reference ensemble fairly successfully when no experimental error is assumed. The Kolmogorov-Smirnov test as well as principal component analysis show that the overlap of the recovered and reference ensembles is significantly enhanced when multiple replicas are used. Reduction of the multiple replica ensembles by clustering successfully yields subensembles with close similarity to the reference ensembles. On the other hand, for a high barrier transition state with two distinct transition state ensembles, the single replica algorithm only samples a few structures of one of the reference ensemble basins. This is due to the fact that the ϕ values are intrinsically ensemble averaged quantities. The replica algorithm with multiple copies does sample both reference ensemble basins. In contrast to the single replica case, the multiple replicas are constrained to reproduce the average ϕ values, but allow fluctuations in ϕ for each individual copy. These fluctuations facilitate a more faithful sampling of the reference ensemble basins. Finally, we test how robustly the reconstruction algorithm can function by introducing errors in ϕ comparable in magnitude to those suggested by some authors. In this circumstance we observe that the chances of ensemble recovery with the replica algorithm are poor using a single replica, but are improved when multiple copies are used. A multimodal transition state ensemble, however, turns out to be more sensitive to large errors in ϕ (if appropriately gauged) and attempts at successful recreation of the reference ensemble with simple replica algorithms can fall short.
Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H
2012-01-01
Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.
NASA Astrophysics Data System (ADS)
Sun, Dongliang; Huang, Guangtuan; Jiang, Juncheng; Zhang, Mingguang; Wang, Zhirong
2013-04-01
Overpressure is one important cause of domino effect in accidents of chemical process equipments. Some models considering propagation probability and threshold values of the domino effect caused by overpressure have been proposed in previous study. In order to prove the rationality and validity of the models reported in the reference, two boundary values of three damage degrees reported were considered as random variables respectively in the interval [0, 100%]. Based on the overpressure data for damage to the equipment and the damage state, and the calculation method reported in the references, the mean square errors of the four categories of damage probability models of overpressure were calculated with random boundary values, and then a relationship of mean square error vs. the two boundary value was obtained, the minimum of mean square error was obtained, compared with the result of the present work, mean square error decreases by about 3%. Therefore, the error was in the acceptable range of engineering applications, the models reported can be considered reasonable and valid.
Estimating clinical chemistry reference values based on an existing data set of unselected animals.
Dimauro, Corrado; Bonelli, Piero; Nicolussi, Paola; Rassu, Salvatore P G; Cappio-Borlino, Aldo; Pulina, Giuseppe
2008-11-01
In an attempt to standardise the determination of biological reference values, the International Federation of Clinical Chemistry (IFCC) has published a series of recommendations on developing reference intervals. The IFCC recommends the use of an a priori sampling of at least 120 healthy individuals. However, such a high number of samples and laboratory analysis is expensive, time-consuming and not always feasible, especially in veterinary medicine. In this paper, an alternative (a posteriori) method is described and is used to determine reference intervals for biochemical parameters of farm animals using an existing laboratory data set. The method used was based on the detection and removal of outliers to obtain a large sample of animals likely to be healthy from the existing data set. This allowed the estimation of reliable reference intervals for biochemical parameters in Sarda dairy sheep. This method may also be useful for the determination of reference intervals for different species, ages and gender.
On the value of the phenotypes in the genomic era.
Gonzalez-Recio, O; Coffey, M P; Pryce, J E
2014-12-01
Genetic improvement programs around the world rely on the collection of accurate phenotypic data. These phenotypes have an inherent value that can be estimated as the contribution of an additional record to genetic gain. Here, the contribution of phenotypes to genetic gain was calculated using traditional progeny testing (PT) and 2 genomic selection (GS) strategies that, for simplicity, included either males or females in the reference population. A procedure to estimate the theoretical economic contribution of a phenotype to a breeding program is described for both GS and PT breeding programs through the increment in genetic gain per unit of increase in estimated breeding value reliability obtained when an additional phenotypic record is added. The main factors affecting the value of a phenotype were the economic value of the trait, the number of phenotypic records already available for the trait, and its heritability. Furthermore, the value of a phenotype was affected by several other factors, including the cost of establishing the breeding program and the cost of phenotyping and genotyping. The cost of achieving a reliability of 0.60 was assessed for different reference populations for GS. Genomic reference populations of more sires with small progeny group sizes (e.g., 20 equivalent daughters) had a lower cost than those reference populations with either large progeny group sizes for fewer genotyped sires, or female reference populations, unless the heritability was large and the cost of phenotyping exceeded a few hundred dollars; then, female reference populations were preferable from an economic perspective. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Jairam, Pushpa M; de Jong, Pim A; Mali, Willem P Th M; Gondrie, Martijn J A; Jacobs, Peter C A; van der Graaf, Yolanda
2014-08-01
To establish age and gender specific reference values for incidental coronary artery and thoracic aorta calcification scores on routine diagnostic CT scans. These reference values can aid in structured reporting and interpretation of readily available imaging data by chest CT readers in routine practice. A random sample of 1572 (57% male, median age 61 years) was taken from a study population of 12,063 subjects who underwent diagnostic chest CT for non-cardiovascular indications between January 2002 and December 2005. Coronary artery and thoracic aorta calcifications were graded using a validated ordinal score. The 25th, 50th and 75th percentile cut points were calculated for the coronary artery and thoracic aorta calcification scores within each age/gender stratum. The 75th percentile cut points for coronary artery calcification scores were higher for men than for women across all age groups, with the exception of the lowest age group. The 75th percentile cut points for thoracic aorta calcifications scores were comparable for both genders across all age groups. Based on the obtained age and gender reference values a calculation tool is provided, that allows one to enter an individual's age, gender and calcification scores to obtain the corresponding estimated percentiles. The calculation tool as provided in this study can be used in daily practice by CT readers to examine whether a subject has high calcifications scores relative to others with the same age and gender. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Choice of Reference Serum Creatinine in Defining Acute Kidney Injury.
Siew, Edward D; Matheny, Michael E
2015-01-01
The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating the estimation of baseline renal function, using PubMed and reference back-tracing within known works. (1) Pre-hospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, (2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations, (3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, (4) using more specific definitions of AKI (e.g., KIDGO stages 2 and 3) may help to reduce the effects of misclassification when using surrogate values and (5) leveraging available clinical data may help refine the estimate of reference creatinine. Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine is needed. © 2015 S. Karger AG, Basel.
Ender, Andreas; Mehl, Albert
2015-01-01
To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 μm (VSE) to 60.2 μm (POE), and precision ranged from 12.3 μm (VSE) to 66.7 μm (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.
Díaz, Alejandro; Galli, Cintia; Tringler, Matías; Ramírez, Agustín; Cabrera Fischer, Edmundo Ignacio
2014-01-01
In medical practice the reference values of arterial stiffness came from multicenter registries obtained in Asia, USA, Australia and Europe. Pulse wave velocity (PWV) is the gold standard method for arterial stiffness quantification; however, in South America, there are few population-based studies. In this research PWV was measured in healthy asymptomatic and normotensive subjects without history of hypertension in first-degree relatives. Normal PWV and the 95% confidence intervals values were obtained in 780 subjects (39.8 ± 18.5 years) divided into 7 age groups (10–98 years). The mean PWV found was 6.84 m/s ± 1.65. PWV increases linearly with aging with a high degree of correlation (r 2 = 0.61; P < 0.05) with low dispersion in younger subjects. PWV progressively increases 6–8% with each decade of life; this tendency is more pronounced after 50 years. A significant increase of PWV over 50 years was demonstrated. This is the first population-based study from urban and rural people of Argentina that provides normal values of the PWV in healthy, normotensive subjects without family history of hypertension. Moreover, the age dependence of PWV values was confirmed. PMID:25215227
In situ LTE exposure of the general public: Characterization and extrapolation.
Joseph, Wout; Verloock, Leen; Goeminne, Francis; Vermeeren, Günter; Martens, Luc
2012-09-01
In situ radiofrequency (RF) exposure of the different RF sources is characterized in Reading, United Kingdom, and an extrapolation method to estimate worst-case long-term evolution (LTE) exposure is proposed. All electric field levels satisfy the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference levels with a maximal total electric field value of 4.5 V/m. The total values are dominated by frequency modulation (FM). Exposure levels for LTE of 0.2 V/m on average and 0.5 V/m maximally are obtained. Contributions of LTE to the total exposure are limited to 0.4% on average. Exposure ratios from 0.8% (LTE) to 12.5% (FM) are obtained. An extrapolation method is proposed and validated to assess the worst-case LTE exposure. For this method, the reference signal (RS) and secondary synchronization signal (S-SYNC) are measured and extrapolated to the worst-case value using an extrapolation factor. The influence of the traffic load and output power of the base station on in situ RS and S-SYNC signals are lower than 1 dB for all power and traffic load settings, showing that these signals can be used for the extrapolation method. The maximal extrapolated field value for LTE exposure equals 1.9 V/m, which is 32 times below the ICNIRP reference levels for electric fields. Copyright © 2012 Wiley Periodicals, Inc.
Qin, X; Tang, G; Gao, R; Guo, Z; Liu, Z; Yu, S; Chen, M; Tao, Z; Li, S; Liu, M; Wang, L; Hou, L; Xia, L; Cheng, X; Han, J; Qiu, L
2017-08-01
The aim of this study was to investigate the reference interval of protein-induced vitamin K absence or antagonist-II (PIVKA-II) in China population and to evaluate its medical decision level for hepatocellular carcinoma (HCC) diagnosis. To determine the reference range for Chinese individuals, a total of 855 healthy subjects in five typical regions of China were enrolled in this study to obtain a 95% reference interval. In a case-control study which recruited the subjects diagnosed with HCC, metastatic liver cancer, bile duct cancer, hepatitis, cirrhosis, other benign liver diseases and the subjects administrated anticoagulant, receiver operating characteristic analysis was used to determine PIVKA-II cutoff value for a medical decision. The concentration of PIVKA-II had no relationship with age or gender and that region was a significant factor associated with the level of PIVKA-II. The 95% reference interval determined in this study for PIVKA-II in Chinese healthy individuals was 28 mAU/mL, and the cutoff value which to distinguish patients with HCC from disease control groups is 36.5 mAU/mL. In clinical applications, it is recommended that each laboratory chooses their own reference interval based on the regional population study or cutoff value for disease diagnosis. © 2017 John Wiley & Sons Ltd.
Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance.
Atieh, Mohammad A; Ritter, André V; Ko, Ching-Chang; Duqum, Ibrahim
2017-09-01
Trueness and precision are used to evaluate the accuracy of intraoral optical impressions. Although the in vivo precision of intraoral optical impressions has been reported, in vivo trueness has not been evaluated because of limitations in the available protocols. The purpose of this clinical study was to compare the accuracy (trueness and precision) of optical and conventional impressions by using a novel study design. Five study participants consented and were enrolled. For each participant, optical and conventional (vinylsiloxanether) impressions of a custom-made intraoral Co-Cr alloy reference appliance fitted to the mandibular arch were obtained by 1 operator. Three-dimensional (3D) digital models were created for stone casts obtained from the conventional impression group and for the reference appliances by using a validated high-accuracy reference scanner. For the optical impression group, 3D digital models were obtained directly from the intraoral scans. The total mean trueness of each impression system was calculated by averaging the mean absolute deviations of the impression replicates from their 3D reference model for each participant, followed by averaging the obtained values across all participants. The total mean precision for each impression system was calculated by averaging the mean absolute deviations between all the impression replicas for each participant (10 pairs), followed by averaging the obtained values across all participants. Data were analyzed using repeated measures ANOVA (α=.05), first to assess whether a systematic difference in trueness or precision of replicate impressions could be found among participants and second to assess whether the mean trueness and precision values differed between the 2 impression systems. Statistically significant differences were found between the 2 impression systems for both mean trueness (P=.010) and mean precision (P=.007). Conventional impressions had higher accuracy with a mean trueness of 17.0 ±6.6 μm and mean precision of 16.9 ±5.8 μm than optical impressions with a mean trueness of 46.2 ±11.4 μm and mean precision of 61.1 ±4.9 μm. Complete arch (first molar-to-first molar) optical impressions were less accurate than conventional impressions but may be adequate for quadrant impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Kokubun, Norito; Sonoo, Masahiro; Imai, Tomihiro; Arimura, Yumiko; Kuwabara, Satoshi; Komori, Tetsuo; Kobayashi, Masahito; Nagashima, Takahide; Hatanaka, Yuki; Tsuda, Emiko; Misawa, Sonoko; Abe, Tatsuya; Arimura, Kimiyoshi
2012-03-01
The aim of this study is to establish reference values for single-fibre electromyography (SFEMG) using concentric needles in a prospective, multicentre study. Voluntary or stimulated SFEMG at the extensor digitorum communis (EDC) or frontalis (FRO) muscles was conducted in 56-63 of a total of 69 normal subjects below the age of 60years at six Japanese institutes. The cut-off values for mean consecutive difference (MCD) of individual potentials were calculated using +2.5 SD or 95% prediction limit (one-tail) of the upper 10th percentile MCD value for individual subjects. The cut-off values for individual MCD (+2.5 SD) were 56.8μs for EDC-V (voluntary SFEMG for EDC), 58.8μs for EDC-S (stimulated SFEMG for EDC), 56.8μs for FRO-V (voluntary SFEMG for FRO) and 51.0μs for FRO-S (stimulated SFEMG for FRO). The false positive rates using these cut-off values were around 2%. The +2.5 SD and 95% prediction limit might be two optimal cut-off values, depending on the clinical question. The obtained reference values were larger than those reported previously using concentric needles, but might better coincide with conventional values. This is the first multicentre study reporting reference values for SFEMG using concentric needles. The way to determine cut-off values and the statistically correct definition of the percentile were discussed. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Value assignment and uncertainty evaluation for single-element reference solutions
NASA Astrophysics Data System (ADS)
Possolo, Antonio; Bodnar, Olha; Butler, Therese A.; Molloy, John L.; Winchester, Michael R.
2018-06-01
A Bayesian statistical procedure is proposed for value assignment and uncertainty evaluation for the mass fraction of the elemental analytes in single-element solutions distributed as NIST standard reference materials. The principal novelty that we describe is the use of information about relative differences observed historically between the measured values obtained via gravimetry and via high-performance inductively coupled plasma optical emission spectrometry, to quantify the uncertainty component attributable to between-method differences. This information is encapsulated in a prior probability distribution for the between-method uncertainty component, and it is then used, together with the information provided by current measurement data, to produce a probability distribution for the value of the measurand from which an estimate and evaluation of uncertainty are extracted using established statistical procedures.
NASA Astrophysics Data System (ADS)
Metairon, S.; Zamboni, C. B.; Suzuki, M. F.; Júnior, C. R. B.; Sant'Anna, O. A.
2011-08-01
The Br, Ca, Cl, K, Na and S concentrations in whole blood of DMDmdx/J and C57BL/6J mice were determined using Neutron Activation Analysis technique. Reference values obtained from twenty one whole blood samples of these strains were analyzed in the IEA-R1 nuclear reactor at IPEN (São Paulo, Brasil). These data contribute for applications in veterinary medicine related to biochemistry analyses using whole blood as well as to evaluate the performance of treatments in muscular dystrophy.
[The reference of normal values of the sacroiliac joint index in bone scintigraphy].
Sebastjanowicz, Przemysław; Iwanowski, Jacek; Piwowarska-Bilska, Hanna; Elbl, Bogumiła; Birkenfeld, Bożena
Scintigraphy of sacroiliac joints as functional imaging provides unique information on the existing disease process. By using radiopharmaceuticals that allow imaging of the metabolic activity within the joint, it is possible to assess the stage of the disease, even when there are no lesions in radiological images. Quantitative analysis of scintigrams of sacroiliac joints is performed by comparing the uptake in both of them in relation to the uptake in the sacral bone area. The values of sacroiliac (SI/S) indices are influenced by the age of the patient, sex, state of health, and a range of individual biological features. Therefore, reference values of SI/S ratios are very important for medical specialists who describe and diagnose locomotor system diseases. The aim of this paper is to develop a reference range of sacroiliac ratios. The innovativeness of this paper involves examining sacroiliac ratios for various age groups, in children and adult patients, taking their sex into consideration. The study comprised a group of 335 people with proper bone scintigraphy. These people were divided into children and patients aged ≥21. Children were divided into 4 age groups (1–5; 6–10; 11–15; 16–20) and adults into 6 age groups (21–30; 31–40; 41–50; 51–60; 61–70; ≥71). Sacroiliac ratios were calculated using the method of three rectangular region of interests located on the left and right sacroiliac joint and on the sacral bone. The sacroiliac ratio was calculated for both joints by dividing the average number of counts within a selected sacroiliac joint by the average number of counts within the sacral bone. SI/S borderline reference values covered the range of 1.18÷2.28 that was obtained for children aged ≤5 and for the group of 11–15-year-olds. Considerable discrepancies in the values of the coefficient for women and men were seen among 31–50-year-olds. Borderline reference results for the entire control group cover the range of 1.18 ±2.28. The lower reference value applies to ≤5-year-olds, whereas the higher value applies to the group of 11–15-year-olds. The standard deviation value obtained was highest in paediatric patients. The results indicate the occurrence of significant individual differences between patients in this age group.
Mirjolet, C; Merlin, J L; Dalban, C; Maingon, P; Azria, D
2016-07-01
In the era of modern treatment delivery, increasing the dose delivered to the target to improve local control might be modulated by the patient's intrinsic radio-sensitivity. A predictive assay based on radio-induced lymphocyte apoptosis quantification highlighted the significant correlation between CD4 and CD8 T-lymphocyte apoptosis and grade 2 or 3 radiation-induced late toxicities. By conducting this assay at several technical platforms, the aim of this study was to demonstrate that radio-induced lymphocyte apoptosis values obtained from two different platforms were comparable. For 25 patients included in the PARATOXOR trial running in Dijon the radio-induced lymphocyte apoptosis results obtained from the laboratory of Montpellier (IRCM, Inserm U1194, France), considered as the reference (referred to as Lab 1), were compared with those from the laboratory located at the Institut de cancérologie de Lorraine (ICL, France), referred to as Lab 2. Different statistical methods were used to measure the agreement between the radio-induced lymphocyte apoptosis data from the two laboratories (quantitative data). The Bland-Altman plot was used to identify potential bias. All statistical tests demonstrated good agreement between radio-induced lymphocyte apoptosis values obtained from both sites and no major bias was identified. Since radio-induced lymphocyte apoptosis values, which predict tolerance to radiotherapy, could be assessed by two laboratories and showed a high level of robustness and consistency, we can suggest that this assay be extended to any laboratories that use the same technique. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer.
Qin, Jia; Wang, Huiying; Rets, Anton; Harari, Saul; Alexis, Herol; Eid, Ikram; Pincus, Matthew R
2013-11-01
Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on the Advia 1650. After upgrading the analyzer to the Advia 1800, creatinine values tended to be more reproducible. As part of a quality assurance investigation to test the reproducibilities of creatinine values, we determined serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58-7.8 mg/dl). These values were determined concurrently with serum blood urea nitrogen (BUN) determinations (range 6.0-84.4 mg/dl) as these two analytes are used together in evaluation of renal function. We determined BUN and creatinine values, using the glutamate dehydrogenase lined enzyme assay system and the Jaffe method, respectively. We find that all values for creatinine on samples stored at 4 °C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CVs), that is, mean CV of 4.55% for creatinine and 2.52% for BUN. One sample with relatively high CV (10.6%) for creatinine was found to have an initial value of 1.1 mg/dl, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dl, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present. We conclude that creatinine and BUN determinations are stable, but occasional spurious creatinine values can occur on the Advia 1800 analyzer. © 2013 Wiley Periodicals, Inc.
Reference Values for Weight, Height, Head Circumference, and Body Mass Index in Turkish Children.
Neyzi, Olcay; Bundak, Rüveyde; Gökçay, Gülbin; Günöz, Hülya; Furman, Andrzej; Darendeliler, Feyza; Baş, Firdevs
2015-12-01
This study aimed to integrate the existing updated reference standards for the growth of Turkish infants and children and to compare these values with World Health Organization (WHO) reference data, data from some European countries, and also with previous local data. Weight, height, and head circumference measurements were obtained on 2,391 boys and 2,102 girls who were regular attenders of a well child clinic and on 1,100 boys and 1,020 girls attending schools in relatively well-off districts in İstanbul. Mean number of measurements per child was 8.2±3.6 in the age group 0-5 years and 5.5±3.3 in the age group 6-18 years. All children were from well-to-do families and all were healthy. All measurements with the exception of measurements at birth, which were based on reported values, were done by trained personnel. The LMS method was used in the analyses and in the construction of the percentile charts. There is an increase in weight for age and body mass index values for age starting in prepubertal ages, indicating an increasing trend for obesity. Compared to WHO reference data, weight and height values in Turkish children were slightly higher in infants and in children younger than 5 years, while they showed similarity to those reported for children from Norway and Belgium. Head circumference values, which were slightly higher than the WHO references in the first 5 years, were comparable to the data on Belgian and Norwegian children in the first 9 years of life. At older ages, Turkish children showed higher values for head circumference. The relatively larger head circumference values were interpreted to reflect a genetic characteristic.
Shafiee, Gita; Ostovar, Afshin; Heshmat, Ramin; Keshtkar, Abbas Ali; Sharifi, Farshad; Shadman, Zhaleh; Nabipour, Iraj; Soltani, Akbar; Larijani, Bagher
2018-01-01
Sacopenia is a common problem in elderly with the adverse outcomes. The objective of this study was to estimate the peak appendicular skeletal muscle mass (ASM) and age of its attainment by sex among the Iranian population. A total of 691 men and women aged 18-94 years participated in this cross-sectional, population-based study in Bushehr, Iran. ASM was measured by dual X-ray absorptiometry. Cutoff points for men and women were established considering two standard deviations (SDs) below the mean values of the skeletal muscle index (SMI) for young reference groups. The relationship between ASM and age was described by the second-degree regression models. Two SDs below the mean SMIs of reference groups were as cutoff values of low muscle mass in Iranian population. The peak ASM values were 21.35 ± 0.12 Kg and 13.68 ± 0.10 Kg, and the age at peak ASM were 26 (24-28) years and 34 (33-35) years for men and women, respectively. Mean and SD of SMI in those ages were 7.01 ± 0.02 Kg/m 2 and 5.44 ± 0.02 Kg/m 2 among men and women, respectively. Calculated cutoff values of low muscle mass among the Iranian population were 7.0 Kg/m 2 and 5.4 Kg/m 2 among men and women, respectively. Iranian reference values of SMI for both genders were similar to Asia Working Group for Sarcopenia recommendation and lower than the United States and European values. Further studies from different nations and the Middle East countries are needed to obtain reference values for populations, enabling the researchers for comparison and also more valid reports on sarcopenia prevalence.
[Reference values of carbohydrates for the Venezuelan population].
Marisela, Granito; Suhey, Pérez; Yolmar, Valero; Colina, Jhoana
2013-12-01
An update of the nutritional recommendations for carbohydrate intake to the Venezuelan population was performed. For this work the concepts, data and methodology followed by other countrie's or groups of countries to obtain and document their own reference, in order to provide basic information to facilitate the establishment of reference values can be revised to better adapt to the Venezuelan population. The data correspond to healthy populations and taken as reference the recommendations of the Food and Nutrition Board of the U.S., the Committees of Experts on Energy and Protein FAO/WHO, among others. As a result of the literature review, the historical caloric formula of population and dietary patterns of Venezuela was propose the consumption of total carbohydrate intake between 50 and 60% of total caloric intake and simple sugars do not exceed 10% of intake. It is suggested to increase the consumption of vegetables, whole grains, legumes, vegetables and whole tropical fruits.
Mederico, Maracelly; Paoli, Mariela; Zerpa, Yajaira; Briceño, Yajaira; Gómez-Pérez, Roald; Martínez, José Luis; Camacho, Nolis; Cichetti, Rosanna; Molina, Zarela; Mora, Yolanda; Valeri, Lenin
2013-05-01
To collect regional reference values of waist circumference (WC), and waist/hip ratio (WHR) in children and adolescents from Merida, Venezuela, and to compare them to international references. A total of 919 students aged 9-17 years from public and private educational establishments were assessed. Weight, height, WC, and WHR were measured. Outliers (± 3 SD Z-Score) were excluded from the data collected. Percentile distribution of the tested variables was done by age and sex. Fifty-one percent of subjects were female, and 52.7% were from public institutions. WC (p=0.001) and WHR (p=0.0001) were statistically higher in boys. With advancing age, WC increased in both sexes, while WHR showed the opposite behavior (p=0.0001 for both). The 90th percentile (pc) for WC ranged from 69.7 and 83.6 cm in girls and from 69.2 and 86.7 cm in boys. The 90th pc values of WHR ranged from 0.79 and 0.91 in girls and from 0.86 and 0.93 in boys. Overall, our WC and WHR values were lower than North American values and similar to those of some Latin American references. Percentile reference charts for WC and WHR specific for age and sex, obtained from a representative sample of children and adolescents from Mérida, Venezuela, are provided. They may be used regionally, both for individual assessment and to implement prevention policies. Copyright © 2012 SEEN. Published by Elsevier Espana. All rights reserved.
Badke, Yvonne M; Bates, Ronald O; Ernst, Catherine W; Fix, Justin; Steibel, Juan P
2014-04-16
Genomic selection has the potential to increase genetic progress. Genotype imputation of high-density single-nucleotide polymorphism (SNP) genotypes can improve the cost efficiency of genomic breeding value (GEBV) prediction for pig breeding. Consequently, the objectives of this work were to: (1) estimate accuracy of genomic evaluation and GEBV for three traits in a Yorkshire population and (2) quantify the loss of accuracy of genomic evaluation and GEBV when genotypes were imputed under two scenarios: a high-cost, high-accuracy scenario in which only selection candidates were imputed from a low-density platform and a low-cost, low-accuracy scenario in which all animals were imputed using a small reference panel of haplotypes. Phenotypes and genotypes obtained with the PorcineSNP60 BeadChip were available for 983 Yorkshire boars. Genotypes of selection candidates were masked and imputed using tagSNP in the GeneSeek Genomic Profiler (10K). Imputation was performed with BEAGLE using 128 or 1800 haplotypes as reference panels. GEBV were obtained through an animal-centric ridge regression model using de-regressed breeding values as response variables. Accuracy of genomic evaluation was estimated as the correlation between estimated breeding values and GEBV in a 10-fold cross validation design. Accuracy of genomic evaluation using observed genotypes was high for all traits (0.65-0.68). Using genotypes imputed from a large reference panel (accuracy: R(2) = 0.95) for genomic evaluation did not significantly decrease accuracy, whereas a scenario with genotypes imputed from a small reference panel (R(2) = 0.88) did show a significant decrease in accuracy. Genomic evaluation based on imputed genotypes in selection candidates can be implemented at a fraction of the cost of a genomic evaluation using observed genotypes and still yield virtually the same accuracy. On the other side, using a very small reference panel of haplotypes to impute training animals and candidates for selection results in lower accuracy of genomic evaluation.
Sanada, K; Miyachi, M; Tanimoto, M; Yamamoto, K; Murakami, H; Okumura, S; Gando, Y; Suzuki, K; Tabata, I; Higuchi, M
2010-09-01
In this study of Japanese men and women, we determine reference values for sarcopenia and test the hypothesis that sarcopenia is associated with risk factors for cardiovascular disease, independent of waist circumference. A total of 1,488 Japanese men and women aged 18-85 years participated in this study. Appendicular muscle mass (AMM) was measured by dual-energy X-ray absorptiometry. Reference values for classes 1 and 2 sarcopenia (skeletal muscle index: AMM/height2, kg m-2) in each sex were defined as values one and two standard deviations below the sex-specific means of reference values obtained in this study from young adults aged 18-40 years. The reference values for class 1 and class 2 sarcopenia were 7.77 and 6.87 kg m-2 in men and 6.12 and 5.46 kg m-2 in women. In subjects both with class 1 and class 2 sarcopenia, body mass index and % body fat were significantly lower than in normal subjects. Despite whole-blood glycohaemoglobin A1c in men with class 1 sarcopenia was significantly higher than in normal subjects, and brachial-ankle pulse wave velocity in women both with class 1 and class 2 sarcopenia were significantly higher than in normal subjects, using one-way ANCOVA with adjustment for the covariate of waist circumference. Although sarcopenia is associated with thin body mass, it is associated with more glycation of serum proteins in men and with greater arterial stiffness in women, independent of waist circumference.
Krawczky, Bruna; Pacheco, Antonio G; Mainenti, Míriam R M
2014-05-01
Reference values for postural alignment in the coronal plane, as measured by computerized photogrammetry, have been established but not for the sagittal plane. The objective of this study is to propose reference values for angular measurements used for postural analysis in the sagittal plane for healthy adults. Electronic databases (PubMed, BVS, Cochrane, Scielo, and Science Direct) were searched using the following key words: evaluation, posture, photogrammetry, and software. Articles published between 2006 and 2012 that used the PAS/SAPO (postural assessment software) were selected. Another inclusion criterion was the presentation of, at least, one of the following measurements: head horizontal alignment, pelvic horizontal alignment, hip angle, vertical alignment of the body, thoracic kyphosis, and lumbar lordosis. Angle samples of the selected articles were grouped 2 by 2 in relation to an overall average, which made possible total average, variance, and SD calculations. Six articles were included, and the following average angular values were found: 51.42° ± 4.87° (head horizontal alignment), -12.26° ± 5.81° (pelvic horizontal alignment), -6.40° ± 3.86° (hip angle), and 1.73° ± 0.94° (vertical alignment of the body). None of the articles contained the measurements for thoracic kyphosis and lumbar lordosis. The reference values can be adopted as reference for postural assessment in future researches if the same anatomical points are considered. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena
2018-04-01
The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.
Bibliography of marine radiation ecology prepared for the Seabed Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultz, V.S.
1980-02-01
References on the effects of ionizing radiation on aquatic organisms have been obtained from a number of sources. Many were obtained from reviews and other publications. Although the primary purpose of preparing this bibliography was to obtain information related to the nuclear wastes Seabed Disposal Biology Program of Sandia Laboratories, freshwater organisms are included as a matter of convenience and also with the belief that such a bibliography would be of interest to a wider audience than that restricted to the Seabed Program. While compilation of a list in an area broad in scope is often somewhat arbitrary, an attemptmore » was made to reference publications that were related to field or laboratory studies of wild species of plants and animals with respect to radiation effects. Complete information concerning each reference are provided without excessive library search. Since one often finds references listed in the literature that are incompletely cited, it was not always possible to locate the reference for verification or completion of the citation. Such references are included where they appeared to be of possible value. When known, a reference is followed with its Nuclear Science Abstract designation, or rarely other abstract sources. Those desiring additional information should check Nuclear Science Abstracts utilizing the abstract number presented or other abstracting sources. In addition, the language of the article, other than English, is given when it is known to me.« less
Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz
2016-01-01
This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis. PMID:26805819
Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz
2016-01-21
This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.
Dissolution assessment of allopurinol immediate release tablets by near infrared spectroscopy.
Smetiško, Jelena; Miljanić, Snežana
2017-10-25
The purpose of this study was to develop a NIR spectroscopic method for assessment of drug dissolution from allopurinol immediate release tablets. Thirty three different batches of allopurinol immediate release tablets containing constant amount of the active ingredient, but varying in excipients content and physical properties were introduced in a PLS calibration model. Correlating allopurinol dissolution reference values measured by the routinely used UV/Vis method, with the data extracted from the NIR spectra, values of correlation coefficient, bias, slope, residual prediction determination and root mean square error of prediction (0.9632, 0.328%, 1.001, 3.58, 3.75%) were evaluated. The obtained values implied that the NIR diffuse reflectance spectroscopy could serve as a faster and simpler alternative to the conventional dissolution procedure, even for the tablets with a very fast dissolution rate (>85% in 15minutes). Apart from the possibility of prediction of the allopurinol dissolution rate, the other multivariate technique, PCA, provided additional data on the non-chemical characteristics of the product, which could not be obtained from the reference dissolution values. Analysis on an independent set of samples confirmed that a difference between the UV/Vis reference method and the proposed NIR method was not significant. According to the presented results, the proposed NIR method may be suitable for practical application in routine analysis and for continuously monitoring the product's chemical and physical properties responsible for expected quality. Copyright © 2017 Elsevier B.V. All rights reserved.
Reference-free error estimation for multiple measurement methods.
Madan, Hennadii; Pernuš, Franjo; Špiclin, Žiga
2018-01-01
We present a computational framework to select the most accurate and precise method of measurement of a certain quantity, when there is no access to the true value of the measurand. A typical use case is when several image analysis methods are applied to measure the value of a particular quantitative imaging biomarker from the same images. The accuracy of each measurement method is characterized by systematic error (bias), which is modeled as a polynomial in true values of measurand, and the precision as random error modeled with a Gaussian random variable. In contrast to previous works, the random errors are modeled jointly across all methods, thereby enabling the framework to analyze measurement methods based on similar principles, which may have correlated random errors. Furthermore, the posterior distribution of the error model parameters is estimated from samples obtained by Markov chain Monte-Carlo and analyzed to estimate the parameter values and the unknown true values of the measurand. The framework was validated on six synthetic and one clinical dataset containing measurements of total lesion load, a biomarker of neurodegenerative diseases, which was obtained with four automatic methods by analyzing brain magnetic resonance images. The estimates of bias and random error were in a good agreement with the corresponding least squares regression estimates against a reference.
Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point
Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie
2008-01-01
This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pathak, Himadri, E-mail: hmdrpthk@gmail.com; Sasmal, Sudip, E-mail: sudipsasmal.chem@gmail.com; Vaval, Nayana
2016-08-21
The open-shell reference relativistic equation-of-motion coupled-cluster method within its four-component description is successfully implemented with the consideration of single- and double- excitation approximations using the Dirac-Coulomb Hamiltonian. At the first attempt, the implemented method is employed to calculate ionization potential value of heavy atomic (Ag, Cs, Au, Fr, and Lr) and molecular (HgH and PbF) systems, where the effect of relativity does really matter to obtain highly accurate results. Not only the relativistic effect but also the effect of electron correlation is crucial in these heavy atomic and molecular systems. To justify the fact, we have taken two further approximationsmore » in the four-component relativistic equation-of-motion framework to quantify how the effect of electron correlation plays a role in the calculated values at different levels of theory. All these calculated results are compared with the available experimental data as well as with other theoretically calculated values to judge the extent of accuracy obtained in our calculations.« less
Cawello, Willi; Schäfer, Carina
2014-08-01
Frequent plasma sampling to monitor pharmacokinetic (PK) profile of antiepileptic drugs (AEDs), is invasive, costly and time consuming. For drugs with a well-defined PK profile, such as AED lacosamide, equations can accurately approximate PK parameters from one steady-state plasma sample. Equations were derived to approximate steady-state peak and trough lacosamide plasma concentrations (Cpeak,ss and Ctrough,ss, respectively) and area under concentration-time curve during dosing interval (AUCτ,ss) from one plasma sample. Lacosamide (ka: ∼2 h(-1); ke: ∼0.05 h(-1), corresponding to half-life of 13 h) was calculated to reach Cpeak,ss after ∼1 h (tmax,ss). Equations were validated by comparing approximations to reference PK parameters obtained from single plasma samples drawn 3-12h following lacosamide administration, using data from double-blind, placebo-controlled, parallel-group PK study. Values of relative bias (accuracy) between -15% and +15%, and root mean square error (RMSE) values≤15% (precision) were considered acceptable for validation. Thirty-five healthy subjects (12 young males; 11 elderly males, 12 elderly females) received lacosamide 100mg/day for 4.5 days. Equation-derived PK values were compared to reference mean Cpeak,ss, Ctrough,ss and AUCτ,ss values. Equation-derived PK data had a precision of 6.2% and accuracy of -8.0%, 2.9%, and -0.11%, respectively. Equation-derived versus reference PK values for individual samples obtained 3-12h after lacosamide administration showed correlation (R2) range of 0.88-0.97 for AUCτ,ss. Correlation range for Cpeak,ss and Ctrough,ss was 0.65-0.87. Error analyses for individual sample comparisons were independent of time. Derived equations approximated lacosamide Cpeak,ss, Ctrough,ss and AUCτ,ss using one steady-state plasma sample within validation range. Approximated PK parameters were within accepted validation criteria when compared to reference PK values. Copyright © 2014 Elsevier B.V. All rights reserved.
Characterization of NIES CRM No. 23 Tea Leaves II for the determination of multielements.
Mori, Ikuko; Ukachi, Miyuki; Nagano, Kimiyo; Ito, Hiroyasu; Yoshinaga, Jun; Nishikawa, Masataka
2010-05-01
A candidate environmental certified reference material (CRM) for the determination of multielements in tea leaves and materials of similar matrix, NIES CRM No. 23 Tea Leaves II, has been developed and characterized by the National Institute for Environmental Studies (NIES), Japan. The origin of the material was tea leaves, which were ground, sieved through a 106-microm mesh, homogenized, and then subdivided into amber glass bottles. The results of homogeneity and stability tests indicated that the material was sufficiently homogeneous and stable for use as a reference material. The property values of the material were statistically determined based on chemical analyses by a network of laboratories using a wide range of methods. Sixteen laboratories participated in the characterization, and nine certified values and five reference values were obtained. These property values of the candidate CRM, which are expressed as mass fractions, were close to the median and/or mean values of the mass fractions of elements in various tea products. The candidate CRM is appropriate for use in analytical quality control and in the evaluation of methods used in the analysis of tea and materials of similar matrix.
Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.
Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon
2016-05-01
Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simbeck, D.J.
1993-12-31
Reference toxicant testing using juvenile freshwater mussels was conducted as part of the CR-ERP biomonitoring study of Clinch River sediments to assess the sensitivity of test organisms and the overall performance of the test. Tests were conducted using moderately hard synthetic water spiked with known concentrations of copper as copper sulfate. Toxicity testing of copper sulfate reference toxicant was conducted from May 12--21, 1993. The organisms used for testing were juvenile fresh-water mussels (Anodonta imbecillis). Results from this test showed an LC{sub 50} value of 1.12 mg Cu/L which is lower than the value of 2.02 mg Cu/L obtained inmore » a previous test. Too few tests have been conducted with copper as the toxicant to determine a normal range of values. Attachments to this report include: Toxicity test bench sheets and statistical analyses; Copper analysis request and results; and Personnel training documentation.« less
An echocardiographic study of healthy Border Collies with normal reference ranges for the breed.
Jacobson, Jake H; Boon, June A; Bright, Janice M
2013-06-01
The objectives of this study were to obtain standard echocardiographic measurements from healthy Border Collies and to compare these measurements to those previously reported for a general population of dogs. Standard echocardiographic data were obtained from twenty apparently healthy Border Collie dogs. These data (n = 20) were compared to data obtained from a general population of healthy dogs (n = 69). Border Collies were deemed healthy based on normal history, physical examination, complete blood count, serum biochemical profile, electrocardiogram, and blood pressure, with no evidence of congenital or acquired heart disease on echocardiographic examination. Standard two dimensional, M-mode, and Doppler echocardiographic measurements were obtained and normal ranges determined. The data were compared to data previously obtained at our hospital from a general population of normal dogs. Two dimensional, M-mode, and Doppler reference ranges for healthy Border Collies are presented in tabular form. Comparison of the weight adjusted M-mode echocardiographic means from Border Collies to those from the general population of dogs showed Border Collies to have larger left ventricular systolic and diastolic dimensions, smaller interventricular septal thickness, and lower fractional shortening. There are differences in some echocardiographic parameters between healthy Border Collies and the general dog population, and the echocardiographic reference ranges provided in this study should be used as breed specific reference values for Border Collies. Copyright © 2013 Elsevier B.V. All rights reserved.
Guzmán, Nora Angélica Núñez; Molina, Daniel Ruiz; Núñez, Benigno Figueroa; Soto-Sosa, Juan Carlos; Abarca, Jorge Eduardo Herrera
2016-12-01
The aim of this clinical trial was to establish the bioequivalence of two tablets containing acetaminophen 650 mg (reference) and acetaminophen 650 mg plus caffeine 65 mg (test), administered orally, in fasting conditions in healthy Mexican volunteers. Blood samples were taken from 21 male and five female individuals, during a 24-h period, to characterize the pharmacokinetic profile of acetaminophen. Plasma samples were quantified by ultra-performance liquid chromatography, tandem mass spectrometry. Pharmacokinetic metrics (maximum plasma concentration, area under the curve from time zero to the last sampling time, and area under the curve from time zero to infinity) were used to determine the 90 % confidence interval of the test/reference coefficient. The geometric mean values for maximum plasma concentration obtained for the reference and test products were 9.46 ± 34.21 and 9.72 ± 32.38 µg/mL, respectively, whereas for the area under the curve from time zero to the last sampling time the values obtained were 34.93 ± 32.58 and 35.89 ± 31.03 µg h/mL for the reference and test formulations, respectively. The 90 % confidence intervals were within the acceptance range (80-125 %). The test product was bioequivalent to the reference product. A faster absorption was seen in the test formulation in the Mexican population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Hao; Ren, Shangping; Garzoglio, Gabriele
Cloud bursting is one of the key research topics in the cloud computing communities. A well designed cloud bursting module enables private clouds to automatically launch virtual machines (VMs) to public clouds when more resources are needed. One of the main challenges in developing a cloud bursting module is to decide when and where to launch a VM so that all resources are most effectively and efficiently utilized and the system performance is optimized. However, based on system operational data obtained from FermiCloud, a private cloud developed by the Fermi National Accelerator Laboratory for scientific workflows, the VM launching overheadmore » is not a constant. It varies with physical resource utilization, such as CPU and I/O device utilizations, at the time when a VM is launched. Hence, to make judicious decisions as to when and where a VM should be launched, a VM launching overhead reference model is needed. In this paper, we first develop a VM launching overhead reference model based on operational data we have obtained on FermiCloud. Second, we apply the developed reference model on FermiCloud and compare calculated VM launching overhead values based on the model with measured overhead values on FermiCloud. Our empirical results on FermiCloud indicate that the developed reference model is accurate. We believe, with the guidance of the developed reference model, efficient resource allocation algorithms can be developed for cloud bursting process to minimize the operational cost and resource waste.« less
Caselli, Thaisa Barboza; Lomazi, Elizete Aparecida; Montenegro, Maria Augusta Santos; Bellomo-Brandão, Maria Angela
2017-01-01
Due to several factors, such as gastrointestinal's diseases and difficulty in feeding, children with Spastic Quadriplegic Cerebral Palsy tend to present nutritional deficits. To assess the nutritional status of pediatric patients with Spastic Quadriplegic Cerebral Palsy according to reference curves for this population and with the measures of folds and circumferences, obtained by the upper arm circumference and triceps skin fold. The data were obtained from: knee-height, estimated height, weight, upper arm circumference, and triceps skin fold. Values of folds and circumferences were compared with Frisancho, and specific curves for these patients were used as reference. The relationship between the values in the growth curve for healthy children, Z-Score, and comparison with the reference curve were verified by Fisher's exact test. We adopted the significance level of 5%. We evaluated 54 patients. The mean age was 10.2 years, and 34 were male, 25 fed by gastrostomy and 29, orally. The frequency of low weight by the reference curve was 22.22%. More than half of the patients presented the parameters indicating lean mass below the 5th percentile. The height of all patients was classified as adequate for the age by the reference curve. Low weight was found in 22% of patients, and there is a greater tendency to present reduced muscle mass and increased fat mass, showing the need for evaluation and appropriate interventions for patients with Spastic Quadriplegic Cerebral Palsy.
Individual and Joint Expert Judgments as Reference Standards in Artifact Detection
Verduijn, Marion; Peek, Niels; de Keizer, Nicolette F.; van Lieshout, Erik-Jan; de Pont, Anne-Cornelie J.M.; Schultz, Marcus J.; de Jonge, Evert; de Mol, Bas A.J.M.
2008-01-01
Objective To investigate the agreement among clinical experts in their judgments of monitoring data with respect to artifacts, and to examine the effect of reference standards that consist of individual and joint expert judgments on the performance of artifact filters. Design Individual judgments of four physicians, a majority vote judgment, and a consensus judgment were obtained for 30 time series of three monitoring variables: mean arterial blood pressure (ABPm), central venous pressure (CVP), and heart rate (HR). The individual and joint judgments were used to tune three existing automated filtering methods and to evaluate the performance of the resulting filters. Measurements The interrater agreement was calculated in terms of positive specific agreement (PSA). The performance of the artifact filters was quantified in terms of sensitivity and positive predictive value (PPV). Results PSA values between 0.33 and 0.85 were observed among clinical experts in their selection of artifacts, with relatively high values for CVP data. Artifact filters developed using judgments of individual experts were found to moderately generalize to new time series and other experts; sensitivity values ranged from 0.40 to 0.60 for ABPm and HR filters (PPV: 0.57–0.84), and from 0.63 to 0.80 for CVP filters (PPV: 0.71–0.86). A higher performance value for the filters was found for the three variable types when joint judgments were used for tuning the filtering methods. Conclusion Given the disagreement among experts in their individual judgment of monitoring data with respect to artifacts, the use of joint reference standards obtained from multiple experts is recommended for development of automatic artifact filters. PMID:18096912
McCain, Stephanie L; Flatland, Bente; Schumacher, Juergen P; Clarke Iii, Elsburgh O; Fry, Michael M
2010-12-01
Advantages of handheld and small bench-top biochemical analyzers include requirements for smaller sample volume and practicality for use in the field or in practices, but little has been published on the performance of these instruments compared with standard reference methods in analysis of reptilian blood. The aim of this study was to compare reptilian blood biochemical values obtained using the Abaxis VetScan Classic bench-top analyzer and a Heska i-STAT handheld analyzer with values obtained using a Roche Hitachi 911 chemical analyzer. Reptiles, including 14 bearded dragons (Pogona vitticeps), 4 blue-tongued skinks (Tiliqua gigas), 8 Burmese star tortoises (Geochelone platynota), 10 Indian star tortoises (Geochelone elegans), 5 red-tailed boas (Boa constrictor), and 5 Northern pine snakes (Pituophis melanoleucus melanoleucus), were manually restrained, and a single blood sample was obtained and divided for analysis. Results for concentrations of albumin, bile acids, calcium, glucose, phosphates, potassium, sodium, total protein, and uric acid and activities of aspartate aminotransferase and creatine kinase obtained from the VetScan Classic and Hitachi 911 were compared. Results for concentrations of chloride, glucose, potassium, and sodium obtained from the i-STAT and Hitachi 911 were compared. Compared with results from the Hitachi 911, those from the VetScan Classic and i-STAT had variable correlations, and constant or proportional bias was found for many analytes. Bile acid data could not be evaluated because results for 44 of 45 samples fell below the lower linearity limit of the VetScan Classic. Although the 2 portable instruments might provide measurements with clinical utility, there were significant differences compared with the reference analyzer, and development of analyzer-specific reference intervals is recommended. ©2010 American Society for Veterinary Clinical Pathology.
Reference interval computation: which method (not) to choose?
Pavlov, Igor Y; Wilson, Andrew R; Delgado, Julio C
2012-07-11
When different methods are applied to reference interval (RI) calculation the results can sometimes be substantially different, especially for small reference groups. If there are no reliable RI data available, there is no way to confirm which method generates results closest to the true RI. We randomly drawn samples obtained from a public database for 33 markers. For each sample, RIs were calculated by bootstrapping, parametric, and Box-Cox transformed parametric methods. Results were compared to the values of the population RI. For approximately half of the 33 markers, results of all 3 methods were within 3% of the true reference value. For other markers, parametric results were either unavailable or deviated considerably from the true values. The transformed parametric method was more accurate than bootstrapping for sample size of 60, very close to bootstrapping for sample size 120, but in some cases unavailable. We recommend against using parametric calculations to determine RIs. The transformed parametric method utilizing Box-Cox transformation would be preferable way of RI calculation, if it satisfies normality test. If not, the bootstrapping is always available, and is almost as accurate and precise as the transformed parametric method. Copyright © 2012 Elsevier B.V. All rights reserved.
Automation of the Image Analysis for Thermographic Inspection
NASA Technical Reports Server (NTRS)
Plotnikov, Yuri A.; Winfree, William P.
1998-01-01
Several data processing procedures for the pulse thermal inspection require preliminary determination of an unflawed region. Typically, an initial analysis of the thermal images is performed by an operator to determine the locations of unflawed and the defective areas. In the present work an algorithm is developed for automatically determining a reference point corresponding to an unflawed region. Results are obtained for defects which are arbitrarily located in the inspection region. A comparison is presented of the distributions of derived values with right and wrong localization of the reference point. Different algorithms of automatic determination of the reference point are compared.
Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults.
Verbanck, Sylvia; Van Muylem, Alain; Schuermans, Daniel; Bautmans, Ivan; Thompson, Bruce; Vincken, Walter
2016-01-01
Monitoring of chronic lung disease requires reference values of lung function indices, including putative markers of small airway function, spanning a wide age range.We measured spirometry, transfer factor of the lung for carbon monoxide (TLCO), static lung volume, resistance and ventilation distribution in a healthy population, studying at least 20 subjects per sex and per decade between the ages of 20 and 80 years.With respect to the Global Lung Function Initiative reference data, our subjects had average z-scores for forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC of -0.12, 0.04 and -0.32, respectively. Reference equations were obtained which could account for a potential dependence of index variability on age and height. This was done for (but not limited to) indices that are pertinent to asthma and chronic obstructive pulmonary disease studies: forced expired volume in 6 s, forced expiratory flow, TLCO, specific airway conductance, residual volume (RV)/total lung capacity (TLC), and ventilation heterogeneity in acinar and conductive lung zones.Deterioration in acinar ventilation heterogeneity and lung clearance index with age were more marked beyond 60 years, and conductive ventilation heterogeneity showed the greatest increase in variability with age. The most clinically relevant deviation from published reference values concerned RV/TLC values, which were considerably smaller than American Thoracic Society/European Respiratory Society-endorsed reference values. Copyright ©ERS 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaBrecque, J.J.; Adames, D.; Parker, W.C.
1981-01-01
A rapid method is presented for the simultaneous determinations of thorium, niobium, lead, and zinc in lateritic material from Cerro Impacto, Estado Bolivar, Venezuela. This technique uses a PDP - 11/05 processor - based photon induced x-ray fluorescence system. The total variations of approximately 5% for concentrations of approximately 1 and 10% for concentrations of approximately 0.1% were obtained with only 500 s of fluorescent time. The values obtained by this method were in agreement with values measured by conventional flame atomic absorption spectroscopy for lead and zinc. The values for thorium measured were in agreement with the reported valuesmore » for the reference materials supplied by NBL.« less
Moreno, Joel; Pérez de Isla, Leopoldo; Campos, Nellys; Guinea, Juan; Domínguez-Perez, Laura; Saltijeral, Adriana; Lennie, Vera; Quezada, Maribel; de Agustín, Alberto; Marcos-Alberca, Pedro; Mahía, Patricia; García-Fernández, Miguel Ángel; Macaya, Carlos
2013-07-01
Current guidelines do not recommend routine assessment of right atrial volume due to the lack of standardized data. Three-dimensional wall-motion tracking (3D-WMT) is a new technology that allows us to calculate volumes without any geometric assumptions. The aim of this study was to define the indexed reference values for two-dimensional echocardiography (2D-echo) and 3D-WMT in adult healthy population and to assess the intermethod, intra- and interobserver agreement. Prospective study. Nonselected healthy subjects were enrolled. Every patient underwent a 2D-echo and a 3D-WMT examination. 2D-echo right atrial volume was obtained by using the area-length method (A-L) from four- and two-chamber view. 3D-echo volumes were assessed by 3D-WMT. Values were indexed by the patient's body surface area. Sixty consecutive healthy subjects were enrolled. Mean age was 57 ± 12-years old and 27 patients (45%) were male. Average indexed right atrial volume obtained by 2D-echo and 3D-echo was 16.76 ± 8.15 mL/m(2) and 19.05 ± 6.87 mL/m(2) , respectively. Univariate linear regression analysis between 2D-echo and 3D-echo right atrial volumes shows a weak correlation between right atrial volume obtained with 2D-echo compared with 3D-WMT (r = 0.29, CI 95% 0.029-0.66, P = 0.033). The agreement analysis shows a similar result (intraclass correlation coefficient [ICC] = 0.28). The intra- and interobserver agreement analysis showed a better agreement when using 3D-WMT. This is the first study that reports the reference indexed right atrial volume values by means of 2D-echo and 3D-echo in healthy population. 3D-WMT is a feasible and reproducible method to determine right atrial volume. © 2013, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Mohamadain, K. E. M.; da Rosa, L. A. R.; Azevedo, A. C. P.; Guebel, M. R. N.; Boechat, M. C. B.; Habani, F.
2004-03-01
Radiation protection in paediatric radiology deserves special attention since it is assumed that children are more sensitive to radiation than adults. The aim of this work is to estimate the entrance skin dose (ESD), the body organ dose (BOD) and the effective dose (E) for chest x-ray exposure of paediatric patients in five large units, three in Sudan and two in Brazil, and to compare the results obtained in both countries with each other and with other values obtained by some European countries. Two examination projections have been investigated, namely, postero-anterior (PA) and antero-posterior (AP). The age intervals considered were: 0-1 year, 1-5 years, 5-10 years and 10-15 years. The results have been obtained with the use of a software called DoseCal. Results of mean ESD for the age interval 1-5 years and AP projection are: 66 µGy (Instituto de Pediatria e Puericultura Martagão Gesteira—IPPMG Hospital), 41, 86 and 68 µGy (Instituto Fernandes Figueira—IFF Hospital), 161 µGy (Omdurman Hospital), 395 µGy (Khartoum Hospital) and 23 µGy (Ahmed Gasim Hospital). In the case of the IFF Hospital, the results refer, respectively, to rooms 1, 2 and for the six mobile equipments. The reference dose values given by the European Guidelines were exceeded in the Khartoum Hospital whilst in all the other hospitals results obtained were below CEC reference values and comparable with the results found in Sweden, Germany, Spain and Italy. The mean E for the same age interval was 11 µSv in the IPPMG, 6, 15 and 11 µSv in the IFF, respectively for rooms 1, 2 and the 6 mobiles, 25 µSv in the Omdurman Hospital, 45 µSv in the Khartoum Hospital and 3 µSv in the Ahmed Gasim Hospital. These are some examples of the large discrepancies that have been detected in this survey.
NASA Astrophysics Data System (ADS)
Madhavi Latha, T.; Peddi Naidu, P.; Madhusudhana Rao, D. N.; Indira Devi, M.
2012-11-01
Electron density profiles for the International Reference Ionosphere (IRI) 2001 and 2007 models have been utilized in evaluating the D-region conductivity parameter in earth ionosphere wave guide calculations. The day to night shift in reflection height of very low frequency (VLF) waves has been calculated using D-region conductivities derived from IRI models and the results are compared with those obtained from phase variation measurements of VLF transmissions from Rugby (England) made at Visakhapatnam (India). The values derived from the models are found to be much lower than those obtained from the experimental measurements. The values derived from the IRI models are in good agreement with those obtained from exponential conductivity model.
Rep. Andrews, Robert E. [D-NJ-1
2010-04-14
Senate - 04/29/2010 Received in the Senate and Read twice and referred to the Committee on Armed Services. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8: Users Guide
NASA Astrophysics Data System (ADS)
Justus, C. G.; James, B. F.
1999-05-01
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8 is presented and its new features are discussed. Mars-GRAM uses new values of planetary reference ellipsoid radii, gravity term, and rotation rate (consistent with current JPL values) and includes centrifugal effects on gravity. The model now uses NASA Ames Global Circulation Model low resolution topography. Curvature corrections are applied to winds and limits based on speed of sound are applied. Altitude of the F1 ionization peak and density scale height, including effects of change of molecular weight with altitude are computed. A check is performed to disallow temperatures below CO2 sublimination. This memorandum includes instructions on obtaining Mars-GRAM source code and data files and running the program. Sample input and output are provided. An example of incorporating Mars-GRAM as an atmospheric subroutine in a trajectory code is also given.
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8: Users Guide
NASA Technical Reports Server (NTRS)
Justus, C. G.; James, B. F.
1999-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8 is presented and its new features are discussed. Mars-GRAM uses new values of planetary reference ellipsoid radii, gravity term, and rotation rate (consistent with current JPL values) and includes centrifugal effects on gravity. The model now uses NASA Ames Global Circulation Model low resolution topography. Curvature corrections are applied to winds and limits based on speed of sound are applied. Altitude of the F1 ionization peak and density scale height, including effects of change of molecular weight with altitude are computed. A check is performed to disallow temperatures below CO2 sublimination. This memorandum includes instructions on obtaining Mars-GRAM source code and data files and running the program. Sample input and output are provided. An example of incorporating Mars-GRAM as an atmospheric subroutine in a trajectory code is also given.
The production and certification of a plutonium equal-atom reference material: NBL CRM 128
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, D.W.; Gradle, C.G.; Soriano, M.D.
This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending ofmore » high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.« less
Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W
2014-11-01
A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.
Herrera, M C; Olivera, J M; Valentinuzzi, M E
1999-07-01
The conductance catheter has gained momentum since its introduction in cardiovascular dynamics back in 1980. However, measuring errors are still blurring its clinical acceptance. The main objective here was to study the effects of the injected saline concentration and temperature on the evaluation of the parallel conductance, Gp, and thus, on the correction volume Vp. That conductance, Gp, and its associated volume, Vp, were computed using 167 saline dilution curves obtained with boluses at different concentrations and temperatures, injected in seven anesthetized closed-chest dogs. The excursion of the total conductance relative to the steady-state value during a saline maneuver showed good correlation with the injected concentration at both studied temperatures. The reference parallel volume (one reference per dog) was defined as the average value obtained with three successive maneuvers, at 6-M concentration and at body temperature; therefore, the method acted as its own reference. The variation of Vp relative to the reference value was clearly dependent on the injected concentration and on its temperature; dispersion was greater at 22 degrees C than at 40 degrees C. The variability would recognize also other causes, such as uncertainty of the extrapolation procedure and the thoracic redistribution of electrical field lines. As conclusion, it is recommended to characterize each maneuver by its concentration and temperature. Body temperature and 6-M concentration appear as the most recommendable combination for the injectate in most animals. Finally, these results intend to characterize the Vp estimation procedure in order to minimize errors. The variability of Vp, in different experimental conditions, demonstrated that both concentration and temperature are additional parameters that may modify the Gp estimate.
Antonacci, Michael A; Zhang, Le; Burant, Alex; McCallister, Drew; Branca, Rosa T
2018-08-01
To assess the effect of macroscopic susceptibility gradients on the gas-phase referenced dissolved-phase 129 Xe (DPXe) chemical shift (CS) and to establish the robustness of a water-based referencing system for in vivo DPXe spectra. Frequency shifts induced by spatially varying magnetic susceptibility are calculated by finite-element analysis for the human head and chest. Their effect on traditional gas-phase referenced DPXe CS is then assessed theoretically and experimentally. A water-based referencing system for the DPXe resonances that uses the local water protons as reference is proposed and demonstrated in vivo in rats. Across the human brain, macroscopic susceptibility gradients can induce an apparent variation in the DPXe CS of up to 2.5 ppm. An additional frequency shift as large as 6.5 ppm can exist between DPXe and gas-phase resonances. By using nearby water protons as reference for the DPXe CS, the effect of macroscopic susceptibility gradients is eliminated and consistent CS values are obtained in vivo, regardless of shimming conditions, region of interest analyzed, animal orientation, or lung inflation. Combining in vitro and in vivo spectroscopic measurements finally enables confident assignment of some of the DPXe peaks observed in vivo. To use hyperpolarized xenon as a biological probe in tissues, the DPXe CS in specific organs/tissues must be reliably measured. When the gas-phase is used as reference, variable CS values are obtained for DPXe resonances. Reliable peak assignments in DPXe spectra can be obtained by using local water protons as reference. Magn Reson Med 80:431-441, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Kim, Changsun; Kim, Hansol
2017-12-09
Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ubeda, Carlos, E-mail: cubeda@uta.cl; Miranda, Patricia; Vano, Eliseo
Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-areamore » product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.« less
Ubeda, Carlos; Miranda, Patricia; Vano, Eliseo
2015-02-01
To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm 2 for <1 yr; 1.74 and 1.90 Gy cm 2 for 1 to <5 yr; 2.83 and 3.22 Gy cm 2 for 5 to <10 yr; and 7.34 and 8.68 Gy cm 2 for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm 2 /kg) for diagnostic and therapeutic procedures. The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate. © 2015 American Association of Physicists in Medicine.
Observable Zitterbewegung in curved spacetimes
NASA Astrophysics Data System (ADS)
Kobakhidze, Archil; Manning, Adrian; Tureanu, Anca
2016-06-01
Zitterbewegung, as it was originally described by Schrödinger, is an unphysical, non-observable effect. We verify whether the effect can be observed in non-inertial reference frames/curved spacetimes, where the ambiguity in defining particle states results in a mixing of positive and negative frequency modes. We explicitly demonstrate that such a mixing is in fact necessary to obtain the correct classical value for a particle's velocity in a uniformly accelerated reference frame, whereas in cosmological spacetime a particle does indeed exhibit Zitterbewegung.
Muraru, Denisa; Onciul, Sebastian; Peluso, Diletta; Soriani, Nicola; Cucchini, Umberto; Aruta, Patrizia; Romeo, Gabriella; Cavalli, Giacomo; Iliceto, Sabino; Badano, Luigi P
2016-02-01
Despite the fact that assessment of right ventricular longitudinal strain (RVLS) carries important implications for patient diagnosis, prognosis, and treatment, its implementation in clinical settings has been hampered by the limited reference values and the lack of uniformity in software, method, and definition used for measuring RVLS. Accordingly, this study was designed to establish (1) the reference values for RVLS by 2-dimensional speckle-tracking echocardiography; and (2) their relationship with demographic, hemodynamic, and cardiac factors. In 276 healthy volunteers (55% women; age, 18-76 years), free wall and septum RVLS (6 segments) and free wall RVLS (3 segments) using both 6- and 3-segment regions of interest were obtained. Feasibility of 6-segment RVLS was 92%. Free wall RVLS from 3- versus 6-segment regions of interest had similar values, yet 6-segment region of interest was more feasible (86% versus 73%; P<0.001) and reproducible. Reference values (lower limits of normality) were as follows: 6-segment RVLS, -24.7±2.6% (-20.0%) for men and -26.7±3.1% (-20.3%) for women; 3-segment RVLS, -29.3±3.4% (-22.5%) for men and -31.6±4.0% (-23.3%) for women (P<0.001). Free wall RVLS was 5±2 strain units (%) larger in magnitude than 6-segment RVLS, 10±4% larger than septal RVLS, and 2±4% larger in women than in men (P<0.001). At multivariable analysis, age, sex, pulmonary systolic pressure, right atrial minimal volume, as well as right atrial and left ventricular longitudinal strain resulted as correlates of RVLS values. This is the largest study providing sex- and method-specific reference values for RVLS. Our data may foster the implementation of 2-dimensional speckle-tracking echocardiography-derived RV analysis in clinical practice. © 2016 American Heart Association, Inc.
Xi, Bo; Zong, Xin'nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y T; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Romdhane, Habiba Ben; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; El Ati, Jalila; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2016-01-26
Several distributions of country-specific blood pressure (BP) percentiles by sex, age, and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limits international comparisons of the prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents by using 7 nationally representative data sets (China, India, Iran, Korea, Poland, Tunisia, and the United States). Data on BP for 52 636 nonoverweight children and adolescents aged 6 to 19 years were obtained from 7 large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and the United States. BP values were obtained with certified mercury sphygmomanometers in all 7 countries by using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th, and 99th) by age and height were estimated by using the Generalized Additive Model for Location Scale and Shape model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. In comparison with the BP levels of the 90th and 95th percentiles of the US Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower, whereas diastolic BP was similar. These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help to identify hypertensive youths in diverse populations. © 2015 American Heart Association, Inc.
Xi, Bo; Zong, Xin’nan; Kelishadi, Roya; Hong, Young Mi; Khadilkar, Anuradha; Steffen, Lyn M.; Nawarycz, Tadeusz; Krzywińska-Wiewiorowska, Małgorzata; Aounallah-Skhiri, Hajer; Bovet, Pascal; Chiolero, Arnaud; Pan, Haiyan; Litwin, Mieczysław; Poh, Bee Koon; Sung, Rita Y.T.; So, Hung-Kwan; Schwandt, Peter; Haas, Gerda-Maria; Neuhauser, Hannelore K.; Marinov, Lachezar; Galcheva, Sonya V; Motlagh, Mohammad Esmaeil; Kim, Hae Soon; Khadilkar, Vaman; Krzyżaniak, Alicja; Ben Romdhane, Habiba; Heshmat, Ramin; Chiplonkar, Shashi; Stawińska-Witoszyńska, Barbara; Ati, Jalila El; Qorbani, Mostafa; Kajale, Neha; Traissac, Pierre; Ostrowska-Nawarycz, Lidia; Ardalan, Gelayol; Parthasarathy, Lavanya; Zhao, Min; Zhang, Tao
2015-01-01
Background Several distributions of country-specific blood pressure (BP) percentiles by sex, age and height for children and adolescents have been established worldwide. However, there are no globally unified BP references for defining elevated BP in children and adolescents, which limit international comparisons of prevalence of pediatric elevated BP. We aimed to establish international BP references for children and adolescents using seven nationally representative data (China, India, Iran, Korea, Poland, Tunisia and USA). Methods and Results Data on BP for 52,636 non-overweight children and adolescents aged 6–19 years were obtained from seven large nationally representative cross-sectional surveys in China, India, Iran, Korea, Poland, Tunisia, and USA. BP values were obtained with certified mercury sphygmomanometers in all seven countries, using standard procedures for BP measurement. Smoothed BP percentiles (50th, 90th, 95th and 99th) by age and height were estimated using the Generalized Additive Model for Location Scale and Shape (GAMLSS) model. BP values were similar between males and females until the age of 13 years and were higher in males than females thereafter. Compared to BP level of the 90th and 95th percentiles of the U.S. Fourth Report at median height, systolic BP of the corresponding percentiles of these international references was lower while diastolic BP was similar. Conclusions These international BP references will be a useful tool for international comparison of the prevalence of elevated BP in children and adolescents and may help identify hypertensive youths in diverse populations. PMID:26671979
NASA Astrophysics Data System (ADS)
Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.
2011-12-01
The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.
Payande, Abolfazl; Tabesh, Hamed; Shakeri, Mohammad Taghi; Saki, Azadeh; Safarian, Mohammad
2013-01-14
Growth charts are widely used to assess children's growth status and can provide a trajectory of growth during early important months of life. The objectives of this study are going to construct growth charts and normal values of weight-for-age for children aged 0 to 5 years using a powerful and applicable methodology. The results compare with the World Health Organization (WHO) references and semi-parametric LMS method of Cole and Green. A total of 70737 apparently healthy boys and girls aged 0 to 5 years were recruited in July 2004 for 20 days from those attending community clinics for routine health checks as a part of a national survey. Anthropometric measurements were done by trained health staff using WHO methodology. The nonparametric quantile regression method obtained by local constant kernel estimation of conditional quantiles curves using for estimation of curves and normal values. The weight-for-age growth curves for boys and girls aged from 0 to 5 years were derived utilizing a population of children living in the northeast of Iran. The results were similar to the ones obtained by the semi-parametric LMS method in the same data. Among all age groups from 0 to 5 years, the median values of children's weight living in the northeast of Iran were lower than the corresponding values in WHO reference data. The weight curves of boys were higher than those of girls in all age groups. The differences between growth patterns of children living in the northeast of Iran versus international ones necessitate using local and regional growth charts. International normal values may not properly recognize the populations at risk for growth problems in Iranian children. Quantile regression (QR) as a flexible method which doesn't require restricted assumptions, proposed for estimation reference curves and normal values.
Bruno, Rosa Maria; Grassi, Guido; Seravalle, Gino; Savoia, Carmine; Rizzoni, Damiano; Virdis, Agostino
2018-04-23
Small-artery remodeling is an early feature of target organ damage in hypertension and retains a negative prognostic value. The aim of the study is to establish age- and sex-specific reference values for media/lumen in small arteries obtained in humans by biopsy. Data from 91 healthy individuals and 200 individuals with cardiovascular risk factors in primary prevention from 4 Italian centers were pooled. Sex-specific equations for media/lumen in the healthy subpopulation, with age as dependent variable, were calculated. These equations were used to calculate predicted media/lumen values in individuals with risk factors and Z scores. The association between classical risk factors and Z scores was then explored by multiple regression analysis. A second-degree polynomial equation model was chosen to obtain sex-specific equations for media/lumen, with age as dependent variable. In the population with risk factors (111 men, age 50.5±14.0 years, hypertension 80.5%), media/lumen Z scores were independently associated with body mass index (standardized β=0.293, P =0.0001), total cholesterol (β=0.191, P =0.031), current smoking (β=0.238, P =0.0005), fasting blood glucose (β=0.204, P =0.003), systolic blood pressure (β=0.233, P =0.023), and female sex (β=0.799, P =0.038). A significant interaction between female sex and total cholesterol was found (β=-0.979, P =0.014). Results were substantially similar in the hypertensive subgroup. A method to calculate individual values of remodeling and growth index based on reference values was also presented. Age- and sex-specific percentiles of media/lumen in a healthy population were estimated. In a predominantly hypertensive population, media/lumen Z scores were associated with major cardiovascular risk factors, including body mass index, cholesterol, smoking, glucose, and systolic blood pressure. Significant sex differences were observed. © 2018 American Heart Association, Inc.
Payande, Abolfazl; Tabesh, Hamed; Shakeri, Mohammad Taghi; Saki, Azadeh; Safarian, Mohammad
2013-01-01
Introduction: Growth charts are widely used to assess children’s growth status and can provide a trajectory of growth during early important months of life. The objectives of this study are going to construct growth charts and normal values of weight-for-age for children aged 0 to 5 years using a powerful and applicable methodology. The results compare with the World Health Organization (WHO) references and semi-parametric LMS method of Cole and Green. Methods: A total of 70737 apparently healthy boys and girls aged 0 to 5 years were recruited in July 2004 for 20 days from those attending community clinics for routine health checks as a part of a national survey. Anthropometric measurements were done by trained health staff using WHO methodology. The nonparametric quantile regression method obtained by local constant kernel estimation of conditional quantiles curves using for estimation of curves and normal values. Results: The weight-for-age growth curves for boys and girls aged from 0 to 5 years were derived utilizing a population of children living in the northeast of Iran. The results were similar to the ones obtained by the semi-parametric LMS method in the same data. Among all age groups from 0 to 5 years, the median values of children’s weight living in the northeast of Iran were lower than the corresponding values in WHO reference data. The weight curves of boys were higher than those of girls in all age groups. Conclusion: The differences between growth patterns of children living in the northeast of Iran versus international ones necessitate using local and regional growth charts. International normal values may not properly recognize the populations at risk for growth problems in Iranian children. Quantile regression (QR) as a flexible method which doesn’t require restricted assumptions, proposed for estimation reference curves and normal values. PMID:23618470
Validation of the SMOS-MIRAS Soil Moisture Product (SML2UDP) in the Pampean Region of Argentina
NASA Astrophysics Data System (ADS)
Niclòs, Raquel; Rivas, Raúl; Sánchez, Juan Manuel; García-Santos, Vicente; Doña, Carolina; Valor, Enric; Holzman, Mauro; Bayala, Martín Ignacio; Carmona, Facundo; Ocampo, Dora; Soldano, Alvaro; Thibeault, Marc
2014-05-01
A validation campaign was carried out to evaluate the SMOS-MIRAS Soil Moisture (SM) SML2UDP product (v5.51) in the Pampean Region of Argentina on February 2013. The study area was selected because it is a vast area of flatlands containing quite homogeneous rainfed croplands, with prevalence of soybean crops, considered SMOS nominal land uses (i.e., crops with vegetation heights not exceeding 1 to 2 m by opposition to trees). Transects of ground SM measurements were collected by Delta-T ThetaProbe ML2x SM probes within four ISEA-4H9 DGG SMOS nodes. The SM data obtained by each probe transect in each parcel were checked by collecting soil samples in the same parcels at the same time and measuring their masses. The gravimetric method was used to obtain reference values. An uncertainty of ± 0.03 m3m-3 was obtained for the ML2x probes. Additionally, they were calibrated in the laboratory for different SMs by saturating and drying a specific and representative variety of soil samples collected from the experimental parcels (loam, clay loam and silt loam samples). This calibration showed again accurate operations for the ML2x probes, which even attain uncertainties of ±0.01 m3m-3, in agreement with the manufacturer. The comparison of the SM transect data collected during the campaign with the SMOS-MIRAS SML2UDP product values showed a negative bias between concurrent SMOS data and ground SM measurements, which means a slight SMOS-MIRAS underestimation, and a standard deviation of ± 0.06 m3m-3. The validation sites were selected taking as reference the locations of permanent SM stations property of the Argentinean Comisión Nacional de Actividades Espaciales (CONAE, National Commission of Space Activities), Instituto Nacional de Tecnología Agropecuaria (INTA, National Institute of Farming Technology) and Instituto de Hidrología de Llanuras (IHLLA, Plain Hydrology Institute). During the campaign several transects were carried out in the parcels where permanent SM stations were located, mainly in those within one of the nodes (with 5 stations inside). The objective was to evaluate the station SM data reliability at the SMOS spatial resolution with the aim of using station data series as reference for SMOS-MIRAS SM product validations. A linear correlation was obtained between the ground SM values and the SM station data within the node, with a coefficient of determination of 0.98 and a fitting error of ± 0.010 m3m-3. Therefore, the station data adjusted to obtain node representative values are being evaluated as reference data to extend the validation of SMOS-retrieved data beyond the campaign results.
Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K
2017-04-01
The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Chuang, Michael L; Gona, Philimon; Hautvast, Gilion L T F; Salton, Carol J; Breeuwer, Marcel; O'Donnell, Christopher J; Manning, Warren J
2014-04-01
To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses, we stratified participants by age-decade and tested for linear trend across age groups. The reference group comprised 685 adults (423F; 61 ± 9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all P = 0.001). Women had greater EF (73 ± 6 versus 71 ± 6%; P = 0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF, and geometry, whereas mass differs between sexes but not age groups. Copyright © 2013 Wiley Periodicals, Inc.
Chuang, Michael L.; Gona, Philimon; Hautvast, Gilion L.T.F.; Salton, Carol J.; Breeuwer, Marcel; O’Donnell, Christopher J.; Manning, Warren J.
2013-01-01
Purpose To determine sex-specific reference values for left ventricular (LV) volumes, mass and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. Methods and Methods We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses we stratified participants by age-decade and tested for linear trend across age groups. Results The reference group comprised 685 adults (423F; 61±9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all p<0.001). Women had greater EF (73±6 vs. 71±6%, p=0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. Conclusion We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF and geometry, while mass differs between sexes but not age groups. PMID:24123369
Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H
2017-04-01
To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.
Farro, Ignacio; Bia, Daniel; Zócalo, Yanina; Torrado, Juan; Farro, Federico; Florio, Lucía; Olascoaga, Alicia; Alallón, Walter; Lluberas, Ricardo; Armentano, Ricardo L.
2012-01-01
Carotid-femoral pulse wave velocity (PWV) has emerged as the gold standard for non-invasive evaluation of aortic stiffness; absence of standardized methodologies of study and lack of normal and reference values have limited a wider clinical implementation. This work was carried out in a Uruguayan (South American) population in order to characterize normal, reference, and threshold levels of PWV considering normal age-related changes in PWV and the prevailing blood pressure level during the study. A conservative approach was used, and we excluded symptomatic subjects; subjects with history of cardiovascular (CV) disease, diabetes mellitus or renal failure; subjects with traditional CV risk factors (other than age and gender); asymptomatic subjects with atherosclerotic plaques in carotid arteries; patients taking anti-hypertensives or lipid-lowering medications. The included subjects (n = 429) were categorized according to the age decade and the blood pressure levels (at study time). All subjects represented the “reference population”; the group of subjects with optimal/normal blood pressures levels at study time represented the “normal population.” Results. Normal and reference PWV levels were obtained. Differences in PWV levels and aging-associated changes were obtained. The obtained data could be used to define vascular aging and abnormal or disease-related arterial changes. PMID:22666551
NASA Technical Reports Server (NTRS)
Sutter, Thomas R.; Wu, K. Chauncey; Riutort, Kevin T.; Laufer, Joseph B.; Phelps, James E.
1992-01-01
A first-generation space crane articulated-truss joint was statically and dynamically characterized in a configuration that approximated an operational environment. The articulated-truss joint was integrated into a test-bed for structural characterization. Static characterization was performed by applying known loads and measuring the corresponding deflections to obtain load-deflection curves. Dynamic characterization was performed using modal testing to experimentally determine the first six mode shapes, frequencies, and modal damping values. Static and dynamic characteristics were also determined for a reference truss that served as a characterization baseline. Load-deflection curves and experimental frequency response functions are presented for the reference truss and the articulated-truss joint mounted in the test-bed. The static and dynamic experimental results are compared with analytical predictions obtained from finite element analyses. Load-deflection response is also presented for one of the linear actuators used in the articulated-truss joint. Finally, an assessment is presented for the predictability of the truss hardware used in the reference truss and articulated-truss joint based upon hardware stiffness properties that were previously obtained during the Precision Segmented Reflector (PSR) Technology Development Program.
Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz
2017-01-01
High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.
Coherent Anti-stokes Raman Spectroscopy (CARS) of gun propellant flames
NASA Technical Reports Server (NTRS)
Mcilwain, M. E.; Harris, L. E.
1980-01-01
Temperature measurements were made in a slightly fuel rich, premixed propane/air reference flame and nitrate ester propellant flames burning in air at atmospheric pressure using coherent anti-stokes raman scattering (CARS). Both single and multiple pulse VARS spectra of nitrogen in the reference flame were in good agreement with calculated and reported values. Single pulse CARS nitrogen spectra obtained in the propellant flames were analyzed to give temperatures consistent with values calculated using the NASA-Lewis thermochemical calculation. Comparison of a 0.1 second separated sequence of single pulse CARS spectra indicate turbulent air mixing in these propellant flames. The CARS spectral results demonstrate that temporal and spatially resolved temperature measurements could be determined in transient, turbulent flames.
Erhart, Stephen M; Young, Alexander S; Marder, Stephen R; Mintz, Jim
2005-08-01
In psychiatric practice, adult patients are most commonly referred for magnetic resonance imaging (MRI) to screen for suspected organic medical diseases of the central nervous system that can mimic psychiatric syndromes. We identified the most common signs and symptoms prompting MRIs to establish the predictive value of these signs and symptoms for clinically pertinent organic syndromes. This study was a retrospective chart review of psychiatric patients at the Veterans Affairs Greater Los Angeles Health Care Center (Los Angeles, Calif.) who were referred for MRI of the brain between 1996 and 2002. Patients referred for evaluation of dementia were excluded. The specific indications leading clinicians to obtain MRI were identified and grouped. In order to offset the uncertain significance of many MRI findings, for this study, the predictive value of each indication was calculated based on the percentage of patients in whom clinical management changed in response to MRI findings rather than on the percentage with any abnormal MRI results. Of 253 patients who had MRIs, 38 (15%) incurred some degree of treatment modification as a result of MRI findings, including 6 patients in whom MRI identified a medical condition that became the focus of treatment. Six indications appeared most likely to prompt clinicians to obtain MRIs. Because pertinent results were associated with each of these indications, statistical evaluation did not reveal significant differences in their predictive values (chi(2) = 4.32, df = 5, p = .505). Unlike prior studies showing no value to screening radioimaging, this study shows MRI can be a useful screening test among patients suspected of having organic psychiatric disorders and that the common indications for MRI employed at one institution were predictive.
NASA Astrophysics Data System (ADS)
Protsyuk, Yu. I.; Kovylianska, O. E.; Protsyuk, S. V.; Yizhakevych, O. M.; Andruk, V. M.; Golovnia, V. V.; Yuldoshev, Q. K.
2017-02-01
The bulk of planet observations was obtained in RI MAO and MAO NASU from 1961 to 1994. Plates from AI UAS were also used. Each plate of NAO was scanned 6 times, in other observatories - only once. All images are processed, most of them are identified and the equatorial coordinates of all objects were obtained. Positional accuracy of the reference stars has value of 0.04"-0.30". Standard deviation of the planets' position is in the range 0.10-0.12 pixels, that corresponds, depending on the scale, from 0".08 to 0".26. The comparison of the new topocentric positions of the planets with JPL/HORIZONS ephemeris was made. Calculation of (O-C) values and their standard deviation is obtained.
NASA Astrophysics Data System (ADS)
Abdul, M.; Farooq, U.; Akbar, Jehan; Saif, F.
2018-06-01
We transform the semi-classical laser equation for single mode homogeneously broadened lasers to a one-dimensional nonlinear map by using the discrete dynamical approach. The obtained mapping, referred to as laser logistic mapping (LLM), characteristically exhibits convergent, cyclic and chaotic behavior depending on the control parameter. Thus, the so obtained LLM explains stable, bistable, multi-stable, and chaotic solutions for output field intensity. The onset of bistability takes place at a critical value of the effective gain coefficient. The obtained analytical results are confirmed through numerical calculations.
Consumer Education Reference Manual.
ERIC Educational Resources Information Center
Tennessee Univ., Knoxville. State Agency for Title I.
This manual contains information for consumer education, which is defined as the process of imparting to an individual the skills, concepts, knowledges, and insights required to help each person evolve his or her own values, evaluate alternative choices in the marketplace, manage personal resources effectively, and obtain the best buys for his or…
Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E
2008-05-23
Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.
Validation of reference genes for quantitative gene expression analysis in experimental epilepsy.
Sadangi, Chinmaya; Rosenow, Felix; Norwood, Braxton A
2017-12-01
To grasp the molecular mechanisms and pathophysiology underlying epilepsy development (epileptogenesis) and epilepsy itself, it is important to understand the gene expression changes that occur during these phases. Quantitative real-time polymerase chain reaction (qPCR) is a technique that rapidly and accurately determines gene expression changes. It is crucial, however, that stable reference genes are selected for each experimental condition to ensure that accurate values are obtained for genes of interest. If reference genes are unstably expressed, this can lead to inaccurate data and erroneous conclusions. To date, epilepsy studies have used mostly single, nonvalidated reference genes. This is the first study to systematically evaluate reference genes in male Sprague-Dawley rat models of epilepsy. We assessed 15 potential reference genes in hippocampal tissue obtained from 2 different models during epileptogenesis, 1 model during chronic epilepsy, and a model of noninjurious seizures. Reference gene ranking varied between models and also differed between epileptogenesis and chronic epilepsy time points. There was also some variance between the four mathematical models used to rank reference genes. Notably, we found novel reference genes to be more stably expressed than those most often used in experimental epilepsy studies. The consequence of these findings is that reference genes suitable for one epilepsy model may not be appropriate for others and that reference genes can change over time. It is, therefore, critically important to validate potential reference genes before using them as normalizing factors in expression analysis in order to ensure accurate, valid results. © 2017 Wiley Periodicals, Inc.
Tamukai, Kenichi; Takami, Yoshinori; Akabane, Yoshihito; Kanazawa, Yuko; Une, Yumi
2011-09-01
Bearded dragons are one of the most popular pet lizard species, and biochemical reference values are useful for health management of these reptiles. The objectives of this study were to measure plasma biochemical values in healthy captive bearded dragons, determine reference values, and evaluate the effects of sex and season on the results. Blood samples were collected from 100 captive healthy bearded dragons in Tokyo during the summer and winter. Plasma biochemical measurements were performed using a dry-slide automated biochemical analyzer. The data were then compared based on sex and season using 2-way ANOVA. Globulin, cholesterol, and calcium concentrations of females were higher in both summer and winter compared with the values obtained for males. Both males and females had higher uric acid concentrations in winter than in summer. When compared with males, females had a higher chloride concentration in summer and a higher total protein concentration and aspartate aminotransferase activity in winter. Potassium concentration in males was lower in winter than in summer, whereas in females cholesterol concentration was lower in winter than in summer. Biochemical values that differed based on sex and season in bearded dragons were similar to those in other lizards. These differences reflect physiologic differences in reproductive status in females and seasonal changes in temperature and hydration status. Plasma biochemical values established for bearded dragons in this study will be useful in the diagnostic assessment of captive animals. ©2011 American Society for Veterinary Clinical Pathology.
Validation of stationary phases in (111)In-pentetreotide planar chromatography.
Moreno-Ortega, E; Mena-Bares, L M; Maza-Muret, F R; Hidalgo-Ramos, F J; Vallejo-Casas, J A
2013-01-01
Since Pall-German stopped manufacturing ITLC-SG, it has become necessary to validate alternative stationary phases. To validate different stationary phases versus ITLC-SG Pall-Gelman in the determination of the radiochemical purity (RCP) of (111)In-pentetreotide ((111)In-Octreoscan) by planar chromatography. We conducted a case-control study, which included 66 (111)In-pentetreotide preparations. We determined the RCP by planar chromatography, using a freshly prepared solution of 0,1M sodium citrate (pH 5) and the following stationary phases: ITLC-SG (Pall-Gelman) (reference method), iTLC-SG (Varian), HPTLC silica gel 60 (Merck), Whatman 1, Whatman 3MM and Whatman 17. For each of the methods, we calculated: PRQ, relative front values (RF) of the radiopharmaceutical and free (111)In, chromatographic development time, resolution between peaks. We compared the results obtained with the reference method. The statistical analysis was performed using the SPSS program. The p value was calculated for the study of statistical significance. The highest resolution is obtained with HPTLC silica gel 60 (Merck). However, the chromatographic development time is too long (mean=33.62minutes). Greater resolution is obtained with iTLC-SG (Varian) than with the reference method, with lower chromatographic development time (mean=3.61minutes). Very low resolutions are obtained with Whatman paper, essentially with Whatman 1 and 3MM. Therefore, we do not recommend their use. Although iTLC-SG (Varian) and HPTLC silica gel 60 (Merck) are suitable alternatives to ITLC-SG (Pall-Gelman) in determining the RCP of (111)In-pentetreotide, iTLC-SG (Varian) is the method of choice due to its lower chromatographic development time. Copyright © 2012 Elsevier España, S.L. and SEMNIM. All rights reserved.
New NIST sediment SRM for inorganic analysis.
Zeisler, Rolf
2004-03-01
NIST maintains a portfolio of more than 1300 standard reference materials (SRM), more than a third of these relating to measurements in the biological and environmental fields. As part of the continuous renewal and replacement efforts, a set of new marine sediments has been recently developed covering organic and inorganic determinations. This paper describes the steps taken in sample preparation, homogeneity assay, and analytical characterization and certification with specific emphasis on SRM 2702 inorganics in marine sediment. Neutron activation analysis showed the SRM to be highly homogeneous, opening the possibility for use with solid sampling techniques. The certificate provides certified mass fraction values for 25 elements, reference values for eight elements, and information values for 11 elements, covering most of the priority pollutants with small uncertainties of only several percent relative. The values were obtained by combining results from different laboratories and techniques using a Bayesian statistical model. An intercomparison carried out in field laboratories with the material before certification illustrates a high commutability of this SRM.
Dosimetric changes with computed tomography automatic tube-current modulation techniques.
Spampinato, Sofia; Gueli, Anna Maria; Milone, Pietro; Raffaele, Luigi Angelo
2018-04-06
The study is aimed at a verification of dose changes for a computed tomography automatic tube-current modulation (ATCM) technique. For this purpose, anthropomorphic phantom and Gafchromic ® XR-QA2 films were used. Radiochromic films were cut according to the shape of two thorax regions. The ATCM algorithm is based on noise index (NI) and three exam protocols with different NI were chosen, of which one was a reference. Results were compared with dose values displayed by the console and with Poisson statistics. The information obtained with radiochromic films has been normalized with respect to the NI reference value to compare dose percentage variations. Results showed that, on average, the information reported by the CT console and calculated values coincide with measurements. The study allowed verification of the dose information reported by the CT console for an ATCM technique. Although this evaluation represents an estimate, the method can be a starting point for further studies.
Impact of Aircraft Emissions on Reactive Nitrogen over the North Atlantic Flight Corridor Region
NASA Technical Reports Server (NTRS)
Koike, M.; Kondo, Y.; Ikeda, H.; Gregory, G. L.; Anderson, B. E.; Sachse, G. W.; Blake, D.; Liu, S. C.; Singh, H. B.; Thompson, A.
1999-01-01
The impact of aircraft emissions on reactive nitrogen in the upper troposphere (UT) and lowermost stratosphere (LS) was estimated using the NO(y)-O3 correlation obtained during the SASS Ozone and NO(x) Experiment (SONEX) carried out over the US continent and North Atlantic Flight Corridor (NAFC) region in October and November 1997. To evaluate the large scale impact, we made a reference NO(y)-O3 relationship in air masses, upon which aircraft emissions were considered to have little impact. For this purpose, the integrated input of NO(x) from aircraft into an air mass along a 10-d back trajectory (DELTA-NO(y)) was calculated based on the ANCAT/EC2 emission inventory. The excess NO(y) (dNO(y)) was calculated from the observed NO(y) and the reference NO(y)-O3 relationship. As a result, a weak positive correlation was found between the dNO(y) and DELTA-NO(y), and dNO(y) and NO(x)/NO(y) values, while no positive correlation between the dNO(y) and CO values was found, suggesting that dNO(y) values can be used as a measure of the NO(x) input from aircraft emissions. The excess NO(y) values calculated from another NO(y)-O3 reference relationship made using in-situ CN data also agreed with these dNO(y) values, within the uncertainties. At the NAFC region (45 N - 60 N), the median value of dNO(y) in the troposphere increased with altitude above 9 km and reached 70 pptv (20% of NO(y)) at 11 km. The excess NO(x) was estimated to be about half of the dNO(y) values, corresponding to 30% of the observed NO(x) level. Higher dNO(y) values were generally found in air masses where O3 = 75 - 125 ppbv, suggesting a more pronounced effect around the tropopause. The median value of dNO(y) in the stratosphere at the NAFC region at 8.5 - 11.5 km was about 120 pptv. The higher dNO(y) values in the LS were probably due to the accumulated effect of aircraft emissions, given the long residence time of affected air in the LS. Similar dNO(y) values were also obtained in air masses sampled over the US continent.
Impact of aircraft emissions on reactive nitrogen over the North Atlantic Flight Corridor region
NASA Astrophysics Data System (ADS)
Koike, M.; Kondo, Y.; Ikeda, H.; Gregory, G. L.; Anderson, B. E.; Sachse, G. W.; Blake, D. R.; Liu, S. C.; Singh, H. B.; Thompson, A. M.; Kita, K.; Zhao, Y.; Sugita, T.; Shetter, R. E.; Toriyama, N.
2000-02-01
The impact of aircraft emissions on reactive nitrogen in the upper troposphere (UT) and lowermost stratosphere (LS) was estimated using the NOy-O3 correlation obtained during the Subsonic Assessment (SASS) Ozone and Nitrogen Oxide Experiment (SONEX) carried out over the U.S. continent and North Atlantic Flight Corridor (NAFC) region in October and November 1997. To evaluate the large-scale impact, we made a reference NOy-O3 relationship in air masses, upon which aircraft emissions were considered to have little impact. For this purpose, the integrated input of NOx from aircraft into an air mass along a 10-day back trajectory (ΔNOy) was calculated based on the Abatement of Nuisance Caused by Air Traffic/European Commission (ANCAT/EC2) emission inventory. The excess NOy (dNOy) was calculated from the observed NOy and the reference NOy-O3 relationship. As a result, a weak positive correlation was found between the dNOy and ΔNOy, and dNOy and NOx/NOy values, while no positive correlation between the dNOy and CO values was found, suggesting that dNOy values can be used as a measure of the NOx input from aircraft emissions. The excess NOy values calculated from another NOy-O3 reference relationship made using in situ condensation nuclei data also agreed with these dNOy values, within the uncertainties. At the NAFC region (45°N-60°N) the median value of dNOy in the troposphere increased with altitude above 9 km and reached 70 parts per trillion by volume (pptv) (20% of NOy) at 11 km. The excess NOx was estimated to be about half of the dNOy values, corresponding to 30% of the observed NOx level. Higher dNOy values were generally found in air masses where O3 = 75-125 ppbv, suggesting a more pronounced effect around the tropopause. The median value of dNOy in the stratosphere at the NAFC region at 8.5-11.5 km was about 120 pptv. The higher dNOy values in the LS were probably due to the accumulated effect of aircraft emissions, given the long residence time of affected air in the LS. Similar dNOy values were also obtained in air masses sampled over the U.S. continent.
Performance of three reflectance calibration methods for airborne hyperspectral spectrometer data.
Miura, Tomoaki; Huete, Alfredo R
2009-01-01
In this study, the performances and accuracies of three methods for converting airborne hyperspectral spectrometer data to reflectance factors were characterized and compared. The "reflectance mode (RM)" method, which calibrates a spectrometer against a white reference panel prior to mounting on an aircraft, resulted in spectral reflectance retrievals that were biased and distorted. The magnitudes of these bias errors and distortions varied significantly, depending on time of day and length of the flight campaign. The "linear-interpolation (LI)" method, which converts airborne spectrometer data by taking a ratio of linearly-interpolated reference values from the preflight and post-flight reference panel readings, resulted in precise, but inaccurate reflectance retrievals. These reflectance spectra were not distorted, but were subject to bias errors of varying magnitudes dependent on the flight duration length. The "continuous panel (CP)" method uses a multi-band radiometer to obtain continuous measurements over a reference panel throughout the flight campaign, in order to adjust the magnitudes of the linear-interpolated reference values from the preflight and post-flight reference panel readings. Airborne hyperspectral reflectance retrievals obtained using this method were found to be the most accurate and reliable reflectance calibration method. The performances of the CP method in retrieving accurate reflectance factors were consistent throughout time of day and for various flight durations. Based on the dataset analyzed in this study, the uncertainty of the CP method has been estimated to be 0.0025 ± 0.0005 reflectance units for the wavelength regions not affected by atmospheric absorptions. The RM method can produce reasonable results only for a very short-term flight (e.g., < 15 minutes) conducted around a local solar noon. The flight duration should be kept shorter than 30 minutes for the LI method to produce results with reasonable accuracies. An important advantage of the CP method is that the method can be used for long-duration flight campaigns (e.g., 1-2 hours). Although this study focused on reflectance calibration of airborne spectrometer data, the methods evaluated in this study and the results obtained are directly applicable to ground spectrometer measurements.
NASA Astrophysics Data System (ADS)
Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae
2014-07-01
In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.
Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae
2014-07-21
In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.
Using smartphone pressure sensors to measure vertical velocities of elevators, stairways, and drones
NASA Astrophysics Data System (ADS)
Monteiro, Martín; Martí, Arturo C.
2017-01-01
We measure the vertical velocities of elevators, pedestrians climbing stairs, and drones (flying unmanned aerial vehicles), by means of smartphone pressure sensors. The barometric pressure obtained with the smartphone is related to the altitude of the device via the hydrostatic approximation. From the altitude values, vertical velocities are derived. The approximation considered is valid in the first hundred meters of the inner layers of the atmosphere. In addition to pressure, acceleration values were also recorded using the built-in accelerometer. Numerical integration was performed, obtaining both vertical velocity and altitude. We show that data obtained using the pressure sensor is significantly less noisy than that obtained using the accelerometer. Error accumulation is also evident in the numerical integration of the acceleration values. In the proposed experiments, the pressure sensor also outperforms GPS, because this sensor does not receive satellite signals indoors and, in general, the operating frequency is considerably lower than that of the pressure sensor. In the cases in which it is possible, comparison with reference values taken from the architectural plans of buildings validates the results obtained using the pressure sensor. This proposal is ideally performed as an external or outreach activity with students to gain insight about fundamental questions in mechanics, fluids, and thermodynamics.
[Muscle strength of the cervical and lumbar spine in triathletes].
Miltner, O; Siebert, C H; Müller-Rath, R; Kieffer, O
2010-12-01
The goal of this study was to analyse the muscle strength of the cervical and lumbar spine in ironman triathletes. The values were compared to the results obtained from a reference group. The test of the triathletes was carried out in an attempt to define a specific strength profile for these athletes. In this study, 20 long-distance triathletes (∅ 37.3 ± 7.6 years of age, ∅ 1.80 ± 0.1 m, ∅ 73.7 ± 6.0 kg) were evaluated with regard to their individual and sport-specific strengths of the cervical spine in 2 planes and of the trunk strengths in all 3 planes of motion. The trunk strength profile of the triathletes revealed good average results in the trunk extensors and the lateral flexors of the left trunk. The reference group is the data base of the company Proxomed®, Alzenau. It is based on results of 1045 untrained, symptom-free subjects of different ages. Lumbar extension: The extension of the force values shows no significant difference from the reference group. Lumbar flexion: The flexion tests show highly significantly lower force values (5.025 ± 0.81 N/kg vs. 6.67 ± 0.6 N/kg) than the reference group. Flexion/extension: In the sagittal plane values for the triathletes demonstrate an imbalance in muscle strength ratios. The abdominal muscles turn in relation to the back extensor muscles too weakly to be very significant. Lumbar rotation: The force values of the athletes in both directions (right: 6.185 ± 1.46 N/kg, left: 7.1 ± 1.57 N/kg vs. 10.05 ± 0.34 N/kg) are highly significantly (p ≤ 0.001) lower than the reference values. Ratio of rotation left/right: The ratio of left/right rotation in the reference group is set at 1 and thus shows an equally strong force level between the two sides. Lumbar lateral flexion: The triathletes do not show any significant differences between the force values. Compared to the reference group there is no significant difference to the left side flexion. In the lateral bending the athletes have significantly better values than the reference group. Ratio of lateral left/right: In the reference group the ratio is set at 1. For triathletes, it shows an average value of 0.93. This difference is not significant. Cervical extension: The extension of the force values (1.96 ± 0.59 N/kg vs. 3.03 ± 0.24 N/kg) shows a highly significant difference from the reference group. Cervical flexion: In flexion (1.3 ± 0.42 N/kg vs. 2.17 ± 0.22 N/kg) triathletes have highly significantly lower strength values than the reference group. Flexion/extension: The triathletes did not differ significantly from the reference values (0.69 ± 0.23 and 0.72 ± 0.08). Lateral cervical spine: In comparison to the reference group (left: 1.67 ± 0.48 N/kg, right: 1.55 ± 0.46 N/kg vs. 2.36 ± 0.15 N/kg) in which there is left/right lateral flexion, there is a highly significant difference. Right lateral flexion is weaker than the left. Ratio of lateral left/right: The triathletes have a significant imbalance in the lateral flexion of the cervical spine compared to the reference group (1.07 ± 0.15 to 1). In conclusion, in the triathlon there is a specific stress that is obviously not an adequate stimulus for the muscles of the cervical spine in order to achieve a balanced musculature and the athletes should be advised to practice a preventive approach with regard to these areas. © Georg Thieme Verlag KG Stuttgart · New York.
Shehata, A B; Rizk, M S; Rend, E A
2016-10-01
Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.
Selecting a database for literature searches in nursing: MEDLINE or CINAHL?
Brazier, H; Begley, C M
1996-10-01
This study compares the usefulness of the MEDLINE and CINAHL databases for students on post-registration nursing courses. We searched for nine topics, using title words only. Identical searches of the two databases retrieved 1162 references, of which 88% were in MEDLINE, 33% in CINAHL and 20% in both sources. The relevance of the references was assessed by student reviewers. The positive predictive value of CINAHL (70%) was higher than that of MEDLINE (54%), but MEDLINE produced more than twice as many relevant references as CINAHL. The sensitivity of MEDLINE was 85% (95% CI 82-88%), and that of CINAHL was 41% (95% CI 37-45%). To assess the ease of obtaining the references, we developed an index of accessibility, based on the holdings of a number of Irish and British libraries. Overall, 47% of relevant references were available in the students' own library, and 64% could be obtained within 48 hours. There was no difference between the two databases overall, but when two topics relating specifically to the organization of nursing were excluded, references found in MEDLINE were significantly more accessible. We recommend that MEDLINE should be regarded as the first choice of bibliographic database for any subject other than one related strictly to the organization of nursing.
Shojaei, Mir Hatef; Djalali, Mamhmoud; Siassi, Fereydoun; Khatami, Mohammad Reza; Boroumand, Mohammad Ali; Eshragian, Mohammad Reza
2009-07-01
High serum levels of lipoprotein(a) and homocysteine are risk factors of cardiovascular disease which are prevalent in patients on hemodialysis. Controversy exists about the effects of hydroxymethylglutaryl-CoA reductase inhibitors on serum lipoprotein(a) levels in patients on hemodialysis. Also, deficiency of some water soluble vitamins and administration of statins may raise serum levels of homocysteine in these patients. This study was designed to investigate serum levels of lipoprotein(a) and homocysteine in patients on hemodialysis who were taking a statin, vitamin B6, and folic acid. We investigated on 152 patients with maintenance hemodialysis who were taking atorvastatin or lovastatin, vitamin B6, and folic acid for at least 6 months. Their serum levels were obtained to measure lipoprotein(a) and homocysteine levels, as well as triglyceride, total cholesterol, high-density lipoprotein cholesterol, and low-density lipoprotein cholesterol. The mean serum values of total cholesterol, high-density lipoprotein cholesterol, and low-density lipoprotein cholesterol and triglyceride were significantly less than the maximum reference values (P < .001). The mean serum level of lipoprotein(a) was also less than the reference value (P = .009), but homocysteine level was 33% higher on average than the reference value (P < .001). Our study demonstrated that in our patients on hemodialysis, the mean serum level of homocysteine was about 30% higher than the reference value although they were receiving vitamin B6 and folic acid. Hence, they were still exposed to the risk of cardiovascular disease.
NASA Astrophysics Data System (ADS)
St Fleur, Sadrac; Courboulex, Francoise; Bertrand, Etienne; Deschamps, Anne; Mercier de Lepinay, Bernard; Prepetit, Claude; Hough, Suzan
2013-04-01
We present the preliminary results of a study with the aim of understanding how some combinations of source and site effects can generate extreme ground motions in the city of Port au Prince. For this study, we have used the recordings of several tens of earthquakes with magnitude larger than 3.0 at 3 to 14 stations from three networks: 3 stations of the Canadian Broad-band network (RNCan), 2 stations of the educational French network (SaE) and 9 stations of the accelerometric network (Bureau des Mines et de l'Energie of Port au Prince and US Geological survey). In order to estimate site effects under each station, we have applied classical spectral ratio methods: The H/V (Horizontal/Vertical) method was first used to select a reference station, which was itself used in a site/reference method. Because a true reference station was not available, we have used successively stations HCEA, then station PAPH, then an average value of 3 stations. In the frequency range studied (0.5 - 20 Hz), we found a site-to-reference ratio up to 3 to 8. However, these values present a large variability, depending on the earthquake recordings. This may indicate that the observed amplification from one station to the other depends not only from the local site effect but also from the source. We then used the same earthquake recordings as Empirical Green's Functions (EGF) in order to simulate the ground motions generated by a virtual earthquake. For this simulation, we have used a stochastic EGF summation method. We have worked on the simulation of a magnitude Mw=6.8 using successively 2 smaller events that occurred on the Leogane fault as EGF. The results obtained using the two events are surprisingly very different. Using the first EGF, we obtained almost the same ground motion values at each station in Port au Prince, whereas with the second EGF, the results highlight large differences. The large variability obtained in the results indicates that a particular combination of site and source effects may be responsible of large ground motions, especially at some given sites.
NASA Astrophysics Data System (ADS)
Condon, D.; Noble, S.; McLean, N.; Bowring, S. A.
2009-12-01
We have determined 238U/235U ratios for a suite of commonly used natural (CRM 112a, SRM 950a, HU-1) and synthetic (IRMM 184 and CRM U500) uranium reference materials in addition to several U-bearing accessory phases (zircon and monazite) by thermal ionisation mass-spectrometry (TIMS) using the IRMM 3636 233U-236U double spike to accurately correct for mass fractionation. The 238U/235U values for the natural uranium reference materials differ, by up to 0.1%, from the widely used ‘consensus’ value (137.88) with all having 238U/235U values less than 137.88. Similarly, initial 238U/235U data from zircon and monazite yield 238U/235U values that are lower than the ‘consensus’ value. The data obtained from U-bearing minerals is used to assess how the uncertainty in the 238U/235U ratio contributes to the systematic discordance observed in 238U/206Pb and 235U/207Pb dates (Mattinson, 2000; Schoene et al., 2006) which has traditionally been wholly attributed to error in the U decay constants. The 238U/235U determinations made on the synthetic reference materials yield results that are considerably more precise and accurate than the certified values (0.02% vs. 0.1% for CRM U500). The calibration of isotopic tracers used for U-daughter geochronology that are partially based upon these reference materials, and the resultant age determinations, will benefit from increased accuracy and precision. Mattinson, J.M., 2000. Revising the “gold standard”—the uranium decay constants of Jaffey et al., 1971. Eos Trans. AGU, Spring Meet. Suppl., Abstract V61A-02. Schoene B., Crowley J.L., Condon D.C., Schmitz M.D., Bowring S.A., 2006, Reassessing the uranium decay constants for geochronology using ID-TIMS U-Pb data. Geochimica et Cosmochimica Acta 70: 426-445
Mota, Stéphanie Machado; Ferreira, Adriano Fernandes; Azevedo, Jair; Nery, Thiago Lopes; Zermiani, Fabiana; Queiroga, Felisbina Luisa
2016-12-01
Sapajus flavius is a species of capuchin monkey classified as critically endangered. Studies related to their biometric values are scarce with incomplete external measurement reports available from only four specimens. Moreover, information regarding proteinogram is limited with no reference to C-reactive protein (CRP) and globulin fractions for this species. Biometric values, CRP, and proteinogram were determined for 12 clinically healthy S. flavius, kept in captivity in João Pessoa, Brazil. The measured values in biometric parameters present a tendency to be higher in males. The CRP mean values from 12 S. flavius were 1.2±0.2 mg/dL. For albumin, alpha, beta, and gamma globulin fraction parameters, the reference interval was calculated. Authors believe that with certain limitations, results obtained can be helpful for the populations in the wild, which could be of great aid in detecting unhealthy individuals and therefore contributing to the conservation of this species. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Direct led-fluorescence method for Mao-B inactivation in the treatment of Parkinson's
NASA Astrophysics Data System (ADS)
Castillo, Jimmy A.; Hung, Jannett; Rodriguez, M.; Bastidas, E.; Laboren, I.; Jaimes, A.
2004-10-01
A led-fluorescence spectroscopy method determinate the inhibitory effects of probe compounds on MAO-B activity is described. In this assay, we demonstrate the possibility of determinate the activity of MAO-B efficiently and rapidly without the use of reference substrate. Measuring variations in fluorescence intensity of MAO-B enzyme during the reaction with inhibitors, L-deprenyl and berberine IC50 and KI values were obtained. For L-deprenyl (IC50 = 0.017 μM and KI = 0.019 μM) and berberine (IC50 = 90 μM and KI = 47 μM) were in agreement to the values obtained with a standard method and literature reported.
Radiopacity Evaluation of Gutta-Percha Points in Thinner Samples than the ANSI/ADA Recommendation.
Petry, Bruna Lucian; Bodanezi, Augusto; Baldasso, Flávia Emi Razera; Delai, Débora; Larentis, Naiara Leites; Fontanella, Vania Regina Camargo; Kopper, Patrícia Maria Poli
2017-01-01
The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).
Development and certification of the new SRM 695 trace elements in multi-nutrient fertilizer
MacKey, E.A.; Cronise, M.P.; Fales, C.N.; Greenberg, R.R.; Leigh, S.D.; Long, S.E.; Marlow, A.F.; Murphy, K.E.; Oflaz, R.; Sieber, J.R.; Rearick, M.S.; Wood, L.J.; Yu, L.L.; Wilson, S.A.; Briggs, P.H.; Brown, Z.A.; Budahn, J.; Kane, P.F.; Hall, W.L.
2007-01-01
During the past seven years, several states within the US have enacted regulations that limit the amounts of selected non-nutritive elements in fertilizers. Internationally, several countries, including Japan, China, and Australia, and the European Union also limit the amount of selected elements in fertilizers. The elements of interest include As, Cd, Co, Cr, Cu, Hg, Mo, Ni, Pb, Se, and Zn. Fertilizer manufacturers and state regulatory authorities, faced with meeting and verifying these limits, need to develop analytical methods for determination of the elements of concern and to validate results obtained using these methods. Until now, there were no certified reference materials available with certified mass fraction values for all elements of interest in a blended, multi-nutrient fertilizer matrix. A new standard reference material (SRM) 695 trace elements in multi-nutrient fertilizer, has been developed to help meet these needs. SRM 695 has recently been issued with certified mass fraction values for seventeen elements, reference values for an additional five elements, and information values for two elements. The certificate of analysis includes an addendum listing percentage recovery for eight of these elements, determined using an acid-extraction inductively-coupled plasma optical-emission spectrometry (ICP-OES) method recently developed and tested by members of the Association of American Plant Food Control Officials. ?? Springer-Verlag 2007.
Quantification of myocardial fibrosis by digital image analysis and interactive stereology
2014-01-01
Background Cardiac fibrosis disrupts the normal myocardial structure and has a direct impact on heart function and survival. Despite already available digital methods, the pathologist’s visual score is still widely considered as ground truth and used as a primary method in histomorphometric evaluations. The aim of this study was to compare the accuracy of digital image analysis tools and the pathologist’s visual scoring for evaluating fibrosis in human myocardial biopsies, based on reference data obtained by point counting performed on the same images. Methods Endomyocardial biopsy material from 38 patients diagnosed with inflammatory dilated cardiomyopathy was used. The extent of total cardiac fibrosis was assessed by image analysis on Masson’s trichrome-stained tissue specimens using automated Colocalization and Genie software, by Stereology grid count and manually by Pathologist’s visual score. Results A total of 116 slides were analyzed. The mean results obtained by the Colocalization software (13.72 ± 12.24%) were closest to the reference value of stereology (RVS), while the Genie software and Pathologist score gave a slight underestimation. RVS values correlated strongly with values obtained using the Colocalization and Genie (r > 0.9, p < 0.001) software as well as the pathologist visual score. Differences in fibrosis quantification by Colocalization and RVS were statistically insignificant. However, significant bias was found in the results obtained by using Genie versus RVS and pathologist score versus RVS with mean difference values of: -1.61% and 2.24%. Bland-Altman plots showed a bidirectional bias dependent on the magnitude of the measurement: Colocalization software overestimated the area fraction of fibrosis in the lower end, and underestimated in the higher end of the RVS values. Meanwhile, Genie software as well as the pathologist score showed more uniform results throughout the values, with a slight underestimation in the mid-range for both. Conclusion Both applied digital image analysis methods revealed almost perfect correlation with the criterion standard obtained by stereology grid count and, in terms of accuracy, outperformed the pathologist’s visual score. Genie algorithm proved to be the method of choice with the only drawback of a slight underestimation bias, which is considered acceptable for both clinical and research evaluations. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/9857909611227193 PMID:24912374
Quantification of myocardial fibrosis by digital image analysis and interactive stereology.
Daunoravicius, Dainius; Besusparis, Justinas; Zurauskas, Edvardas; Laurinaviciene, Aida; Bironaite, Daiva; Pankuweit, Sabine; Plancoulaine, Benoit; Herlin, Paulette; Bogomolovas, Julius; Grabauskiene, Virginija; Laurinavicius, Arvydas
2014-06-09
Cardiac fibrosis disrupts the normal myocardial structure and has a direct impact on heart function and survival. Despite already available digital methods, the pathologist's visual score is still widely considered as ground truth and used as a primary method in histomorphometric evaluations. The aim of this study was to compare the accuracy of digital image analysis tools and the pathologist's visual scoring for evaluating fibrosis in human myocardial biopsies, based on reference data obtained by point counting performed on the same images. Endomyocardial biopsy material from 38 patients diagnosed with inflammatory dilated cardiomyopathy was used. The extent of total cardiac fibrosis was assessed by image analysis on Masson's trichrome-stained tissue specimens using automated Colocalization and Genie software, by Stereology grid count and manually by Pathologist's visual score. A total of 116 slides were analyzed. The mean results obtained by the Colocalization software (13.72 ± 12.24%) were closest to the reference value of stereology (RVS), while the Genie software and Pathologist score gave a slight underestimation. RVS values correlated strongly with values obtained using the Colocalization and Genie (r>0.9, p<0.001) software as well as the pathologist visual score. Differences in fibrosis quantification by Colocalization and RVS were statistically insignificant. However, significant bias was found in the results obtained by using Genie versus RVS and pathologist score versus RVS with mean difference values of: -1.61% and 2.24%. Bland-Altman plots showed a bidirectional bias dependent on the magnitude of the measurement: Colocalization software overestimated the area fraction of fibrosis in the lower end, and underestimated in the higher end of the RVS values. Meanwhile, Genie software as well as the pathologist score showed more uniform results throughout the values, with a slight underestimation in the mid-range for both. Both applied digital image analysis methods revealed almost perfect correlation with the criterion standard obtained by stereology grid count and, in terms of accuracy, outperformed the pathologist's visual score. Genie algorithm proved to be the method of choice with the only drawback of a slight underestimation bias, which is considered acceptable for both clinical and research evaluations. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/9857909611227193.
Use of ultrasound to monitor physical properties of soybean oil
NASA Astrophysics Data System (ADS)
Baêsso, R. M.; Oliveira, P. A.; Morais, G. C.; Alvarenga, A. V.; Costa-Félix, R. P. B.
2016-07-01
The study of the monitoring physical properties of soybean oil was performed. The pulse-echo method allowed measuring the density and viscosity of the oil in real time and accurately. The physical property values were related to the acoustic time of flight ratio, dimensionless parameter that can be obtained from any reference. In our case, we used the time of flight at 20°C as reference and a fixed distance between the transducer and the reflector. Ultrasonic monitoring technique employed here has shown promising in the analysis of edible oils.
Laboratory techniques and rhythmometry
NASA Technical Reports Server (NTRS)
Halberg, F.
1973-01-01
Some of the procedures used for the analysis of rhythms are illustrated, notably as these apply to current medical and biological practice. For a quantitative approach to medical and broader socio-ecologic goals, the chronobiologist gathers numerical objective reference standards for rhythmic biophysical, biochemical, and behavioral variables. These biological reference standards can be derived by specialized computer analyses of largely self-measured (until eventually automatically recorded) time series (autorhythmometry). Objective numerical values for individual and population parameters of reproductive cycles can be obtained concomitantly with characteristics of about-yearly (circannual), about-daily (circadian) and other rhythms.
Modelling reverse characteristics of power LEDs with thermal phenomena taken into account
NASA Astrophysics Data System (ADS)
Ptak, Przemysław; Górecki, Krzysztof
2016-01-01
This paper refers to modelling characteristics of power LEDs with a particular reference to thermal phenomena. Special attention is paid to modelling characteristics of the circuit protecting the considered device against the excessive value of the reverse voltage and to the description of the temperature influence on optical power. The network form of the worked out model is presented and some results of experimental verification of this model for the selected diodes operating at different cooling conditions are described. The very good agreement between the calculated and measured characteristics is obtained.
Joseph, Gabby B.; McCulloch, Charles E.; Nevitt, Michael C.; Heilmeier, Ursula; Nardo, Lorenzo; Lynch, John A.; Liu, Felix; Baum, Thomas; Link, Thomas M.
2015-01-01
Objective The purpose of this study was 1) to establish a gender- and BMI-specific reference database of cartilage T2 values, and 2) to assess the associations between cartilage T2 values and gender, age, and BMI in knees without radiographic osteoarthritis or MRI-based (WORMS 0/1) evidence of cartilage degeneration. Design 481 subjects between the ages of 45-65 years with Kellgren-Lawrence Scores 0/1 in the study knee were selected from the Osteoarthritis Initiative database. Baseline morphologic cartilage 3T MRI readings (WORMS scoring) and T2 measurements (resolution=0.313mmx0.446mm) were performed in the medial femur, lateral femur, medial tibia, lateral tibia, and patella compartments. In order to create a reference database, a logarithmic transformation was applied to the data to obtain the 5th-95th percentile values for T2. Results Significant differences in mean cartilage T2 values were observed between joint compartments. Although females had slightly higher T2 values than males in a majority of compartments, the differences were only significant in the medial femur (p<0.0001). A weak positive association was seen between age and T2 in all compartments, and was most pronounced in the patella (3.27% increase in median T2/10 years, p=0.009). Significant associations between BMI and T2 were observed, and were most pronounced in the lateral tibia (5.33% increase in median T2/5 kg/m2 increase in BMI, p<0.0001), and medial tibia (4.81% increase in median T2 /5 kg/m2 increase in BMI, p<0.0001). Conclusions This study established the first reference database of T2 values in a large sample of morphologically normal cartilage plates in knees without radiographic knee osteoarthritis. While cartilage T2 values were weakly associated with age and gender, they had the highest correlations with BMI. PMID:25680652
Abe, Yuki; Shibata, Yoko; Igarashi, Akira; Inoue, Sumito; Sato, Kento; Sato, Masamichi; Nemoto, Takako; Kobayashi, Maki; Nishiwaki, Michiko; Kimura, Tomomi; Tokairin, Yoshikane; Kayama, Takamasa; Kubota, Isao
2016-05-01
The forced oscillation technique (FOT) can measure respiratory system resistance and reactance under tidal volume respiration. MostGraph is a device that incorporates the FOT and enables the immediate, three-dimensional visualization of resistance and reactance parameters. The aim of this study was to establish MostGraph reference values for middle-aged and elderly Japanese individuals. From 2004 to 2006, 3253 subjects living in Takahata, Yamagata underwent spirometry. Of these, 872 again underwent spirometry in 2011, and 784 (368 men, ages 46-89 years; 416 women, ages 47-90 years) underwent FOT examinations using MostGraph-01. In this study population, 19.0% of the men and 91.5% of the women were life-long never smokers. Abnormal spirometric findings were observed in 30.2% of the men and 14.6% of the women. Although the respiratory system resistance and reactance parameters obtained using MostGraph were not distributed normally, normal distribution was achieved via natural logarithm (R5, R20, Fres, and ALX), square root (R5-R20), or exponential (X5) transformation. Furthermore, the transformed values were converted back to the actual values after determining the values representing one and two standard deviations from the mean. Respiratory system resistance and reactance reference values were determined using MostGraph in middle-aged and elderly Japanese individuals who participated in annual health checkups. Copyright © 2016 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
Cholesterol and vitamin D content of eggs in the U.S. retail market
USDA-ARS?s Scientific Manuscript database
Nationwide sampling in the U.S. of whole large eggs, to update values in the USDA National Nutrient Database for Standard Reference (SR) (http://www.ars.usda.gov/nutrientdata), was conducted in 2000-2001 and again in 2010. Retail cartons of large eggs were obtained from 12 supermarket locations usi...
An Experimental Weight Function Method for Stress Intensity Factor Calibration.
1980-04-01
in accuracy to the ones obtained by Macha (Reference 10) for the laser interferometry technique. The values of KI from the interpolating polynomial...Measurement. Air Force Material Laboratories, AFML-TR-74-75, July 1974. 10. D. E. Macha , W. N. Sharpe Jr., and A. F. Grandt Jr., A Laser Interferometry
Height and Weight of Southeast Asian Preschool Children in Northern California.
ERIC Educational Resources Information Center
Dewey, Kathryn G.; And Others
1986-01-01
Anthropometric data were obtained from 526 Southeast Asian preschool children during 1980-84. Mean weights and heights were substantially below the National Center for Health Statistics (NCHS) 50th percentile, but rates of weight and height gain were similar to reference values, indicating adequate growth after arrival in the United States.…
Erhardt, E; Foraita, R; Pigeot, I; Barba, G; Veidebaum, T; Tornaritis, M; Michels, N; Eiben, G; Ahrens, W; Moreno, L A; Kovács, E; Molnár, D
2014-09-01
To establish age- and sex-specific reference values for serum leptin and adiponectin in normal-weight 3.0-8.9-year old European children. Blood samples for hormone analysis were taken from 1338 children of the IDEFICS (Identification and prevention of Dietary- and lifestyle-induced health Effects in Children and infantS) study cohort. Only normal-weight children aged 3.0-8.9 years were included (n=539) in our analysis. Using the General Additive Model for Location Scale and Shape, age- and sex-specific percentiles were derived. The influence of under/overweight and obesity on the proposed reference curves based on normal-weight children was investigated in several sensitivity analyses using the sample without obese children (n=1015) and the whole study sample (n=1338). There was a negative age trend of adiponectin blood levels and a positive trend of leptin levels in boys and girls. Percentiles derived for girls were generally higher than those obtained for boys. The corresponding age-specific differences of the 97th percentile ranged from -2.2 to 4.6 μg ml(-1) and from 2.2 to 4.8 ng ml(-1) for adiponectin and leptin, respectively. According to our knowledge, these are the first reference values of leptin and adiponectin in prepubertal, normal-weight children. The presented adiponectin and leptin reference curves may allow for a more differentiated interpretation of children's hormone levels in epidemiological and clinical studies.
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children
Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young
2016-01-01
Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.
Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young
2016-09-01
Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.
Reference values for respiratory rate in the first 3 years of life.
Rusconi, F; Castagneto, M; Gagliardi, L; Leo, G; Pellegatta, A; Porta, N; Razon, S; Braga, M
1994-09-01
Raised respiratory rate is a useful sign to diagnose lower respiratory infections in childhood. However, the normal range for respiratory rate has not been defined in a proper, large sample. To assess the respiratory rate in a large number of infants and young children in order to construct percentile curves by age; to determine the repeatability to the assessment using a stethoscope and compare it with observation. Respiratory rate was recorded for 1 minute with a stethoscope in 618 infants and children, aged 15 days to 3 years old, without respiratory infections or any other severe disease when awake and calm and when asleep. In 50 subjects we compared respiratory rate taken 30 to 60 minutes apart to assess repeatability, and in 50 others we compared simultaneous counts obtained by stethoscope versus observation. Repeatability was good as the standard deviation of differences was 2.5 breaths/minute in awake and 1.7 breaths/minute in asleep children. Respiratory rate obtained with a stethoscope was systematically higher than that obtained by observation (mean difference 2.6 breaths/minute in awake and 1.8 breaths/minute in asleep children; P = .015 and P < .001, respectively). A decrease in respiratory rate with age was seen for both states, and it was faster in the first few months of life when also a greater dispersion of values was observed. A second degree polynomial curve accurately fitted the data. Reference percentile values were developed from these data. The repeatability of respiratory rate measured with a stethoscope was good. Percentile curves would be particularly helpful in the first months of life when the decline in respiratory rate is very rapid and prevents to use cut off values for defining "normality."
Dimova, Violeta; Oertel, Bruno G; Lötsch, Jörn
2017-01-01
Skin sensitivity to sensory stimuli varies among different body areas. A standardized clinical quantitative sensory testing (QST) battery, established for the diagnosis of neuropathic pain, was used to assess whether the magnitude of differences between test sites reaches clinical significance. Ten different sensory QST measures derived from thermal and mechanical stimuli were obtained from 21 healthy volunteers (10 men) and used to create somatosensory profiles bilateral from the dorsum of the hands (the standard area for the assessment of normative values for the upper extremities as proposed by the German Research Network on Neuropathic Pain) and bilateral at volar forearms as a neighboring nonstandard area. The parameters obtained were statistically compared between test sites. Three of the 10 QST parameters differed significantly with respect to the "body area," that is, warmth detection, thermal sensory limen, and mechanical pain thresholds. After z-transformation and interpretation according to the QST battery's standard instructions, 22 abnormal values were obtained at the hand. Applying the same procedure to parameters assessed at the nonstandard site forearm, that is, z-transforming them to the reference values for the hand, 24 measurements values emerged as abnormal, which was not significantly different compared with the hand (P=0.4185). Sensory differences between neighboring body areas are statistically significant, reproducing prior knowledge. This has to be considered in scientific assessments where a small variation of the tested body areas may not be an option. However, the magnitude of these differences was below the difference in sensory parameters that is judged as abnormal, indicating a robustness of the QST instrument against protocol deviations with respect to the test area when using the method of comparison with a 95 % confidence interval of a reference dataset.
Dental technician pneumoconiosis mimicking lung cancer.
Uyar, Meral; Sokucu, Oral; Sanli, Maruf; Filiz, Ayten; Ali Ikidag, Mehmet; Feridun Isik, Ahmet; Bakir, Kemal
2015-09-01
A 47-year-old man was referred for assessment of bilateral lymph node enlargement identified on a routine chest radiograph. Positron emission tomography showed high standardized uptake values (SUVmax: 20.5) in right supraclavicular, right intercostal, and multiple mediastinal lymph nodes. Biopsy samples obtained from the right upper and left lower paratracheal nodes by mediastinoscopy revealed granulomatous inflammation. Clinical and laboratory findings indicated a diagnosis of dental technician pneumoconiosis. The patient is alive and well 3 years after diagnosis. This case highlights the importance of obtaining an occupational history.
Detection of human papillomavirus DNA in patients referred to a family practice colposcopy clinic.
Holman, J R
1996-01-01
Human papillomavirus (HPV) is strongly implicated in the pathogenesis of cervical neoplasia. The ability of a commercially available kit (Virapap/Viratype) to detect evidence of HPV is compared with cervical cytology, colposcopy, and directed biopsies. During a period of 16 months, cervical samples from 241 consecutive new patients referred for a colposcopy examination were obtained for HPV-DNA hybridization typing according to the kit instructions. Samples were sent to a reference laboratory for testing. The results were compared with results of the colposcopy examination, cervical cytology, and directed cervical biopsy samples processed and evaluated by our hospital laboratory. HPV DNA was detected in 27 of 107 patients who had abnormal colposcopy findings for a sensitivity of 25 +/- 7.5 percent at the 90 percent confidence interval. One of 134 patients with normal findings was positive for a specificity of 99 +/- 5 percent at the 95 percent confidence interval. Based on a 75 percent probability of HPV in the population, the positive predictive value was 99 percent and the negative predictive value 30 percent. With the low negative predictive value and sensitivity, HPV-DNA testing by this commercial kit is not an adequate tool for screening HPV in this population.
Masala, Silvia; Ahmed, Trifa; Bergvall, Christoffer; Westerholm, Roger
2011-12-01
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.
Liu, Xiang; Peng, Dejun; Tian, Hao; Lu, Chengyu
2017-01-01
To develop an equation for the evaluation of renal function in rats using three dilutions of plasma samples and to validate this method by comparison with a reference method. The investigation was conducted in Sprague-Dawley (SD) rats after delivery of three doses of iohexol, with blood samples collected before and after dosage using a quantitative blood collection method. Plasma iohexol concentrations were detected by high performance liquid chromatography (HPLC). The extraction recovery of iohexol from plasma was >97.30% and the calibration curve was linear (r 2 = 0.9997) over iohexol concentrations ranging from 10 to 1000 µg/mL. The method had an RE of <9.310 and intra- and inter-day RSD of <5.137% and <3.693%, respectively. The plasma clearance values obtained from the equation correlated closely (r = 0.763) with those obtained using the reference method. The relatively correlation in the results obtained using the method under investigation and the reference method indicate that this new equation can be used for preliminary assessment of renal function in rats. © 2016 Asian Pacific Society of Nephrology.
Coban, Ahmet Yilmaz; Uzun, Meltem
2013-01-01
Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA) in detecting isoniazid (INH) and rifampicin (RIF) resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results. PMID:24402143
[Assessment of dietary intake and urinary excretion of sodium and potassium in adults].
Cornejo, Karen; Pizarro, Fernando; Atalah, Eduardo; Galgani, José E
2014-06-01
Hypertension is associated with elevated sodium and low potassium intakes. The determination of sodium and potassium intake by dietary records is inaccurate, being its measurement from 24-h urine collection the reference method. To determine urinary sodium and potassium excretion in adults. To compare dietary sodium and potassium intake and their excretion from an isolated urine sample against the reference method. Seventy healthy adults aged 35 ± 8 years with a body mass index 25 ± 2 kg/m² (36 women) were studied. Urine was collected over 24 h, including an isolated urine sample taken in fasting conditions. Additionally, three 24-h dietary records were performed. Reported sodium and potassium intake was 2,720 ± 567 and 1,068 ± 433 mg/day, respectively. In turn, urinary excretion of sodium and potassium was 4,770 ± 1,532 and 1,852 ± 559 mg/day, respectively. These latter values were significantly higher than those obtained by dietary records. Furthermore, the urinary sodium and potassium excretion estimated from an isolated urine sample was 4,839 ± 1,355 and 1,845 ± 494 mg/day, respectively. These values were similar to those obtained with a 24 h urine collection. Dietary records underestimated electrolyte intake when compared with the reference method. Using an isolated urine sample to estimate electrolyte intake may be a reliable alternative.
Reference values of renal tubular function tests are dependent on age and kidney function.
Bech, Anneke P; Wetzels, Jack F M; Nijenhuis, Tom
2017-12-01
Electrolyte disorders due to tubular disorders are rare, and knowledge about validated clinical diagnostic tools such as tubular function tests is sparse. Reference values for tubular function tests are based on studies with small sample size in young healthy volunteers. Patients with tubular disorders, however, frequently are older and can have a compromised renal function. We therefore evaluated four tubular function tests in individuals with different ages and renal function. We performed furosemide, thiazide, furosemide-fludrocortisone, and desmopressin tests in healthy individuals aged 18-50 years, healthy individuals aged more than 50 years and individuals with compromised renal function. For each tubular function test we included 10 individuals per group. The responses in young healthy individuals were in line with previously reported values in literature. The maximal increase in fractional chloride excretion after furosemide was below the lower limit of young healthy individuals in 5/10 older subjects and in 2/10 patients with compromised renal function. The maximal increase in fractional chloride excretion after thiazide was below the lower limit of young healthy individuals in 6/10 older subjects and in 7/10 patients with compromised renal function. Median maximal urine osmolality after desmopressin was 1002 mosmol/kg H 2 O in young healthy individuals, 820 mosmol/kg H 2 O in older subjects and 624 mosmol/kg H 2 O in patients with compromised renal function. Reference values for tubular function tests obtained in young healthy adults thus cannot simply be extrapolated to older patients or patients with compromised kidney function. Larger validation studies are needed to define true reference values in these patient categories. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Sutinen, Saila; Lahti, Satu; Nuttall, Nigel M; Sanders, Anne E; Steele, Jimmy G; Allen, P Finbarr; Slade, Gary D
2007-06-01
The length of the reference period used in surveys of subjective oral health may have a marked influence on the responses obtained. We aimed to evaluate the effect of a 1-month (RP-1) vs. a 12-month (RP-12) reference period in the Oral Health Impact Profile (OHIP-14) questionnaire. Using a randomized cross-over design, RP-1 and RP-12 OHIP-14 questionnaires were administered, 1 month apart, to two samples of Finnish adults, namely people awaiting orthognathic surgery (n = 104) and non-patient workers (n = 111). The effect of the reference period was computed by subtracting RP-1 OHIP-14 severity scores from RP-12 OHIP-14 severity scores (DeltaRP). Potential order effects were assessed by comparing DeltaRP between groups completing the RP-1 vs. the RP-12 questionnaire first. Mean OHIP-14 severity scores were slightly higher when the RP-12 questionnaire was administered first, but mean DeltaRP values were below the value of 2.5 considered clinically meaningful, and all 95% confidence intervals for DeltaRP included zero. No order effects in the OHIP-14 severity scores were observed. Therefore, although a standardized reference period of 12 months is recommended, in population surveys the use of a shorter reference period does not appear to influence responses.
NASA Astrophysics Data System (ADS)
van Loon, W. M. G. M.; Boon, A. R.; Gittenberger, A.; Walvoort, D. J. J.; Lavaleye, M.; Duineveld, G. C. A.; Verschoor, A. J.
2015-09-01
The Benthic Ecosystem Quality Index 2 (BEQI2) is the Dutch multi-metric index (MMI) for assessing the status and trend of benthic invertebrates in transitional and coastal waters for the Water Framework Directive (WFD). It contains the same indicators, i.e. species richness, Shannon index and AMBI, as in the multivariate m-AMBI. The latter MMI has been adopted by several European countries in the context of WFD implementation. In contrast to m-AMBI, the BEQI2 calculation procedure has been strongly simplified and consists of two steps, i.e. the separate indicator values are normalized using their long-term reference values resulting in three Ecological Quality Ratios (EQRs), which are subsequently averaged to give one BEQI2 value. Using this method only small numbers of samples need to be analysed by Dutch benthos laboratories annually, without the necessity to co-analyse a larger historical dataset. BEQI2 EQR values appeared to correlate quantitatively very well with m-AMBI EQR values. In addition, a data pooling procedure has been added to the BEQI2 tool which enables the pooling of small core samples (0.01-0.025 m2) into larger standardized data pools of 0.1 m2 in order to meet the data requirements of the AMBI indicator and to obtain comparable reference values. Furthermore, the BEQI2 tool automatically and efficiently converts species synonym names into standardized species names. The BEQI2 tool has been applied to all Dutch benthos data monitored by Rijkswaterstaat in the period of 1991-2010 in the transitional and coastal waters and salt lakes and these results are reported here for the first time. Reference values for species richness and Shannon index (99 percentile values) and AMBI reference values (1 percentile values) were estimated for all water body-ecotopes and are discussed. BEQI2 results for all these water bodies are discussed in view of natural and human pressures. The pressure sensitivity of the BEQI2 for sewage and dredging/dumping, via the state variables oxygen and suspended matter respectively, was demonstrated.
Aprea, Maria Cristina; Scapellato, Maria Luisa; Valsania, Maria Carmen; Perico, Andrea; Perbellini, Luigi; Ricossa, Maria Cristina; Pradella, Marco; Negri, Sara; Iavicoli, Ivo; Lovreglio, Piero; Salamon, Fabiola; Bettinelli, Maurizio; Apostoli, Pietro
2017-04-21
Biological reference values (RVs) explore the relationships between humans and their environment and habits. RVs are fundamental in the environmental field for assessing illnesses possibly associated with environmental pollution, and also in the occupational field, especially in the absence of established biological or environmental limits. The Italian Society for Reference Values (SIVR) determined to test criteria and procedures for the definition of RVs to be used in the environmental and occupational fields. The paper describes the SIVR methodology for defining RVs of xenobiotics and their metabolites. Aspects regarding the choice of population sample, the quality of analytical data, statistical analysis and control of variability factors are considered. The simultaneous interlaboratory circuits involved can be expected to increasingly improve the quality of the analytical data. Examples of RVs produced by SIVR are presented. In particular, levels of chromium, mercury, ethylenethiourea, 3,5,6-trichloro-2-pyridinol, 2,5-hexanedione, 1-hydroxypyrene and t,t-muconic acid measured in urine and expressed in micrograms/g creatinine (μg/g creat) or micrograms/L (μg/L) are reported. With the proposed procedure, SIVR intends to make its activities known to the scientific community in order to increase the number of laboratories involved in the definition of RVs for the Italian population. More research is needed to obtain further RVs in different biological matrices, such as hair, nails and exhaled breath. It is also necessary to update and improve the present reference values and broaden the portfolio of chemicals for which RVs are available. In the near future, SIVR intends to expand its scientific activity by using a multivariate approach for xenobiotics that may have a common origin, and to define RVs separately for children who may be exposed more than adults and be more vulnerable.
Uncertainties in obtaining high reliability from stress-strength models
NASA Technical Reports Server (NTRS)
Neal, Donald M.; Matthews, William T.; Vangel, Mark G.
1992-01-01
There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.
Atherton, Rachel R.; Williams, Jane E.; Wells, Jonathan C. K.; Fewtrell, Mary S.
2013-01-01
Background Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. Objectives (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. Design FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height2/Z)) in 927 subjects aged 3.8–22.0 y (211 healthy, 716 patients). Results DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (±0.62); FFM SDS −0.04 (±0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤−2 or ≥2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. Conclusions DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome. PMID:23690932
Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S
2013-01-01
Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.
Ramírez-Vélez, R; Correa-Bautista, J E; Martínez-Torres, J; Méneses-Echavez, J F; González-Ruiz, K; González-Jiménez, E; Schmidt-RioValle, J; Lobelo, F
2016-01-01
Background/Objectives: Indices predictive of central obesity include waist circumference (WC) and waist-to-height ratio (WHtR). These data are lacking for Colombian adults. This study aims at establishing smoothed centile charts and LMS tables for WC and WHtR; appropriate cutoffs were selected using receiver-operating characteristic analysis based on data from the representative sample. Subjects/Methods: We used data from the cross-sectional, national representative nutrition survey (ENSIN, 2010). A total of 83 220 participants (aged 20–64) were enroled. Weight, height, body mass index (BMI), WC and WHtR were measured and percentiles calculated using the LMS method (L (curve Box-Cox), M (curve median), and S (curve coefficient of variation)). Receiver operating characteristics curve analyses were used to evaluate the optimal cutoff point of WC and WHtR for overweight and obesity based on WHO definitions. Results: Reference values for WC and WHtR are presented. Mean WC and WHtR increased with age for both genders. We found a strong positive correlation between WC and BMI (r=0.847, P< 0.01) and WHtR and BMI (r=0.878, P<0.01). In obese men, the cutoff point value is 96.6 cm for the WC. In women, the cutoff point value is 91.0 cm for the WC. Receiver operating characteristic curve for WHtR was also obtained and the cutoff point value of 0.579 in men, and in women the cutoff point value was 0.587. A high sensitivity and specificity were obtained. Conclusions: This study presents first reference values of WC and WHtR for Colombians aged 20–64. Through LMS tables for adults, we hope to provide quantitative tools to study obesity and its complications. PMID:27026425
USDA-ARS?s Scientific Manuscript database
Knowledge of the extent of the symptoms of a plant disease, generally referred to as severity, is key to both fundamental and applied aspects of plant pathology. Most commonly, severity is obtained visually and the accuracy of each estimate (closeness to the actual value) by individual raters is par...
Escobar, Raul G; Munoz, Karin T; Dominguez, Angelica; Banados, Pamela; Bravo, Maria J
2017-01-01
In this study we aimed to determine the maximal isometric muscle strength of a healthy, normal-weight, pediatric population between 6 and 15 years of age using hand-held dynamometry to establish strength reference values. The secondary objective was determining the relationship between strength and anthropometric parameters. Four hundred normal-weight Chilean children, split into 10 age groups, separated by 1-year intervals, were evaluated. Each age group included between 35 and 55 children. The strength values increased with increasing age and weight, with a correlation of 0.83 for age and 0.82 for weight. The results were similar to those reported in previous studies regarding the relationships among strength, age, and anthropometric parameters, but the reported strength differed. These results provide normal strength parameters for healthy and normal-weight Chilean children between 6 and 15 years of age and highlight the relevance of ethnicity in defining reference values for muscle strength in a pediatric population. Muscle Nerve 55: 16-22, 2017. © 2016 Wiley Periodicals, Inc.
Discrimination of human and nonhuman blood using Raman spectroscopy with self-reference algorithm
NASA Astrophysics Data System (ADS)
Bian, Haiyi; Wang, Peng; Wang, Jun; Yin, Huancai; Tian, Yubing; Bai, Pengli; Wu, Xiaodong; Wang, Ning; Tang, Yuguo; Gao, Jing
2017-09-01
We report a self-reference algorithm to discriminate human and nonhuman blood by calculating the ratios of identification Raman peaks to reference Raman peaks and choosing appropriate threshold values. The influence of using different reference peaks and identification peaks was analyzed in detail. The Raman peak at 1003 cm-1 was proved to be a stable reference peak to avoid the influencing factors, such as the incident laser intensity and the amount of sample. The Raman peak at 1341 cm-1 was found to be an efficient identification peak, which indicates that the difference between human and nonhuman blood results from the C-H bend in tryptophan. The comparison between self-reference algorithm and partial least square method was made. It was found that the self-reference algorithm not only obtained the discrimination results with the same accuracy, but also provided information on the difference of chemical composition. In addition, the performance of self-reference algorithm whose true positive rate is 100% is significant for customs inspection to avoid genetic disclosure and forensic science.
Marrodán Serrano, María Dolores; González-Montero de Espinosa, Marisa; Herráez, Ángel; Alfaro, Emma Laura; Felipe Bejarano, Ignacio; Carmenate, María Margarita; Prado, Consuelo; Beatriz Lomaglio, Delia; López-Ejeda, Noemí; Martínez, Antonio; Mesa, María Soledad; Méndez Pérez, Betty; Meléndez, Juana María; Moreno Romero, Susana; Pacheco, Jose Luis; Vázquez, Vanessa; Dipierri, José E
2015-12-01
the assessment of the skinfold thickness is an objective measure of adiposity. Therefore, it is a useful tool for nutritional diagnosis and prevention of metabolic risk associated with excess fat in chilhood and adolescence. to provide percentiles of subscapular and triceps skinfolds for Hispanic American schoolchildren and compare them with those published by the Centers for Disease Control and Prevention (CDC) from United States, that it have been commonly used as a reference in most of these countries. subscapular and triceps skinfolds were measured in 9.973 schoolchildren 4-19 aged from Spain, Argentina, Cuba, Venezuela and Mexico with Holtain caliper with 0.2 mm accuracy. Percentiles were obtained with the LMS statistical method and were presented in tables divided in stages of 6 months and in curves graphics. The difference between Hispanic American and CDC mean values were provided for P3, P50 and P97 in mm and also were graphically represented. skinfolds measurements obviously increased with age in both sexes but, in boys, this increase is much more marked in highest percentiles between 8 and 13 years; this maximum is reached earlier than what occurs in CDC reference. In both sexes, all percentiles analized in Hispanic American schoolchildren were higher than the CDC reference except P97 up to 10 or 13 years that was notably smaller. the skinfolds percentiles of Hispanic American children and adolescents differ from CDC that are usually used as reference. The values of subscapular and triceps skinfolds provided in this study, could be applied to populations of a similar ethnic background, especially in comparative studies of body composition. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Collinson, Paul O; Heung, Yen Ming; Gaze, David; Boa, Frances; Senior, Roxy; Christenson, Robert; Apple, Fred S
2012-01-01
We sought to determine the effect of patient selection on the 99th reference percentile of 2 sensitive and 1 high-sensitivity (hs) cardiac troponin assays in a well-defined reference population. Individuals>45 years old were randomly selected from 7 representative local community practices. Detailed information regarding the participants was collected via questionnaires. The healthy reference population was defined as individuals who had no history of vascular disease, hypertension, or heavy alcohol intake; were not receiving cardiac medication; and had blood pressure<140/90 mmHg, fasting blood glucose<110 mg/dL (approximately 6 mmol/L), estimated creatinine clearance>60 mL·min(-1)·(1.73 m2)(-1), and normal cardiac function according to results of echocardiography. Samples were stored at -70 °C until analysis for cardiac troponin I (cTnI) and cardiac troponin T (cTnT) and N-terminal pro-B-type natriuretic peptide. Application of progressively more stringent population selection strategies to the initial baseline population of 545 participants until the only individuals who remained were completely healthy according to the study criteria reduced the number of outliers seen and led to a progressive decrease in the 99th-percentile value obtained for the Roche hs-cTnT assay and the sensitive Beckman cTnI assay but not for the sensitive Siemens Ultra cTnI assay. Furthermore, a sex difference found in the baseline population for the hs-cTnT (P=0.0018) and Beckman cTnI assays (P<0.0001) progressively decreased with more stringent population selection criteria. The reference population selection strategy significantly influenced the 99th percentile reference values determined for troponin assays and the observed sex differences in troponin concentrations.
Kalkwarf, Heidi J.; Gilsanz, Vicente; Lappe, Joan M.; Oberfield, Sharon; Shepherd, John A.; Frederick, Margaret M.; Huang, Xiangke; Lu, Ming; Mahboubi, Soroosh; Hangartner, Thomas; Winer, Karen K.
2011-01-01
Context: Deficits in bone acquisition during growth may increase fracture risk. Assessment of bone health during childhood requires appropriate reference values relative to age, sex, and population ancestry to identify bone deficits. Objective: The objective of this study was to provide revised and extended reference curves for bone mineral content (BMC) and areal bone mineral density (aBMD) in children. Design: The Bone Mineral Density in Childhood Study was a multicenter longitudinal study with annual assessments for up to 7 yr. Setting: The study was conducted at five clinical centers in the United States. Participants: Two thousand fourteen healthy children (992 males, 22% African-Americans) aged 5–23 yr participated in the study. Intervention: There were no interventions. Main Outcome Measures: Reference percentiles for BMC and aBMD of the total body, lumbar spine, hip, and forearm were obtained using dual-energy x-ray absorptiometry for Black and non-Black children. Adjustment factors for height status were also calculated. Results: Extended reference curves for BMC and aBMD of the total body, total body less head, lumbar spine, total hip, femoral neck, and forearm for ages 5–20 yr were constructed relative to sex and age for Black and non-Black children. Curves are similar to those previously published for 7–17 year olds. BMC and aBMD values were greater for Black vs. non-Black children at all measurement sites. Conclusions: We provide here dual-energy x-ray absorptiometry reference data on a well-characterized cohort of 2012 children and adolescents. These reference curves provide the most robust reference values for the assessment and monitoring of bone health in children and adolescents in the literature to date. PMID:21917867
Watanabe, Ayumi; Inoue, Yusuke; Asano, Yuji; Kikuchi, Kei; Miyatake, Hiroki; Tokushige, Takanobu
2017-01-01
The specific binding ratio (SBR) was first reported by Tossici-Bolt et al. for quantitative indicators for dopamine transporter (DAT) imaging. It is defined as the ratio of the specific binding concentration of the striatum to the non-specific binding concentration of the whole brain other than the striatum. The non-specific binding concentration is calculated based on the region of interest (ROI), which is set 20 mm inside the outer contour, defined by a threshold technique. Tossici-Bolt et al. used a 50% threshold, but sometimes we couldn't define the ROI of non-specific binding concentration (reference region) and calculate SBR appropriately with a 50% threshold. Therefore, we sought a new method for determining the reference region when calculating SBR. We used data from 20 patients who had undergone DAT imaging in our hospital, to calculate the non-specific binding concentration by the following methods, the threshold to define a reference region was fixed at some specific values (the fixing method) and reference region was visually optimized by an examiner at every examination (the visual optimization method). First, we assessed the reference region of each method visually, and afterward, we quantitatively compared SBR calculated based on each method. In the visual assessment, the scores of the fixing method at 30% and visual optimization method were higher than the scores of the fixing method at other values, with or without scatter correction. In the quantitative assessment, the SBR obtained by visual optimization of the reference region, based on consensus of three radiological technologists, was used as a baseline (the standard method). The values of SBR showed good agreement between the standard method and both the fixing method at 30% and the visual optimization method, with or without scatter correction. Therefore, the fixing method at 30% and the visual optimization method were equally suitable for determining the reference region.
Sinha, Nikita; Reddy, K Mahendranadh; Gupta, Nidhi; Shastry, Y M
2017-01-01
Occlusal plane (OP) differs considerably in participants with skeletal Class I and Class II participants. In this study, cephalometrics has been used to help in the determination of orientation of the OP utilizing the nonresorbable bony anatomic landmarks in skeletal Class II participants and an attempt has been made to predict and examine the OP in individuals with skeletal class II jaw relationship. One hundred dentulous participants with skeletal Class II malocclusion who came to the hospital for correcting their jaw relationship participated in the study. Their right lateral cephalogram was taken using standardized procedures, and all the tracings were manually done by a single trained examiner. The cephalograms which were taken for the diagnostic purpose were utilized for the study, and the patient was not exposed to any unnecessary radiation. The numerical values obtained from the cephalograms were subjected to statistical analysis. Pearson's correlation of <0.001 was considered significant, and a linear regression analysis was performed to determine a formula which would help in the determination of orientation of the OP in Class II edentulous participants. Pearson's correlation coefficient and linear regression analysis were performed, and a high correlation was found between A2 and (A2 + B2)/(B2 + C2) with " r " value of 0.5. A medium correlation was found between D2 and (D2 + E2)/(E2 + F2) with " r " value of 0.42. The formula obtained for posterior reference frame through linear regression equation was y = 0.018* × +0.459 and the formula obtained for anterior reference frame was y1 = 0.011* × 1 + 0.497. It was hypothesized that by substituting these formulae in the cephalogram obtained from the Class II edentate individual, the OP can be obtained and verified. It was concluded that cephalometrics can be useful in examining the orientation of OP in skeletal Class II participants.
Aranha, V P; Saxena, S; Moitra, M; Narkeesh, K; Arumugam, N; Samuel, A J
2017-01-01
This study aimed to estimate normative range for reaction time using ruler drop method for school-going South Asian children between 6 and 12 years of age. A cross-sectional study was used to evaluate the reaction time for 204 children. Normal values for each age group were obtained. The results of multiple linear regressions showed a decrease in the reaction time values with age, and a significant change occurring between six and eight years of age. No difference in reaction time was obtained between boys and girls. Ruler drop method is an easy to use test and the results of this study provide a normative data for age groups 6-12 years ranging from 214.2ms to 248.8ms. These values can serve as a reference to screen children with delayed reaction time. Copyright © 2016 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Haiyun; Zhang, Junping; Li, Yonghe
2018-05-01
Under the weight charge policy, the weigh in motion data at a toll station on the Jing-Zhu Expressway were collected. The statistic analysis of vehicle load data was carried out. For calculating the operating vehicle load effects on bridges, by Monte Carlo method used to generate random traffic flow and influence line loading method, the maximum bending moment effect of simple supported beams were obtained. The extreme value I distribution and normal distribution were used to simulate the distribution of the maximum bending moment effect. By the extrapolation of Rice formula and the extreme value I distribution, the predicted values of the maximum load effects were obtained. By comparing with vehicle load effect according to current specification, some references were provided for the management of the operating vehicles and the revision of the bridge specifications.
NASA Technical Reports Server (NTRS)
Geimer, W.
1995-01-01
This report documents the final reliability prediction performed on the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A). The A1 Module contains Channels 3 through 15, and is referred to herein as 'EOS/AMSU-A1'. The A2 Module contains Channels 1 and 2, and is referred herein as 'EOS/AMSU-A2'. The 'specified' figures were obtained from Aerojet Reports 8897-1 and 9116-1. The predicted reliability figure for the EOS/AMSU-A1 meets the specified value and provides a Mean Time Between Failures (MTBF) of 74,390 hours. The predicted reliability figure for the EOS/AMSU-A2 meets the specified value and provides a MTBF of 193,110 hours.
Marinsky, J.A.; Reddy, M.M.
1990-01-01
The molecular weight and aggregation tendency of a reference-soil fulvic acid in Armadale horizon Bh were determined by vapor-pressure osmometry using tetrahydrofuran and water as solvents. With tetrahydrofuran, number-average molecular weight values of 767 ?? 34 and 699 ?? 8 daltons were obtained from two separate sets of measurements. Two sets of measurements with water also yielded values within this range (754 ?? 70 daltons) provided that the fulvic acid concentration in water did not exceed 7 mg ml-1; at higher concentrations (9.1-13.7 mg ml-1) a number-average molecular weight of 956 ?? 25 daltons was resolved, providing evidence of molecular aggregation. Extension of these studies to 80% neutralized fulvic acid showed that a sizeable fraction of the sodium counter ion is not osmotically active.
Certified reference materials (GBW09170 and 09171) of creatinine in human serum.
Dai, Xinhua; Fang, Xiang; Shao, Mingwu; Li, Ming; Huang, Zejian; Li, Hongmei; Jiang, You; Song, Dewei; He, Yajuan
2011-02-15
Creatinine is the most widely used clinical marker for assessing renal function. Concentrations of creatinine in human serum need to be carefully checked in order to ensure accurate diagnosis of renal function. Therefore, development of certified reference materials (CRMs) of creatinine in serum is of increasing importance. In this study, two new CRMs (Nos. GBW09170 and 09171) for creatinine in human serum have been developed. They were prepared with mixtures of several dozens of healthy people's and kidney disease patient's serum, respectively. The certified values of 8.10, 34.1 mg/kg for these two CRMs have been assigned by liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method which was validated by using standard reference material (SRM) of SRM909b (a reference material obtained from National Institute of Standards and Technology, NIST). The expanded uncertainties of certified values for low and high concentrations were estimated to be 1.2 and 1.1%, respectively. The certified values were further confirmed by an international intercomparison for the determination of creatinine in human serum (Consultative Committee for Amount of Substance, CCQM) of K80 (CCQM-K80). These new CRMs of creatinine in human serum pool are totally native without additional creatinine spiked for enrichment. These new CRMs are capable of validating routine clinical methods for ensuring accuracy, reliability and comparability of analytical results from different clinical laboratories. They can also be used for instrument validation, development of secondary reference materials, and evaluating the accuracy of high order clinical methods for the determination of creatinine in human serum. Copyright © 2011 Elsevier B.V. All rights reserved.
Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source.
Tschentscher, Juliane; Hochheim, Sven; Brüning, Hauke; Brune, Kai; Voit, Kay-Michael; Imlau, Mirco
2016-03-30
Beam parameters of a probing laser source in an optical riblet sensor are studied by considering the high demands on a sensors' precision and reliability for the determination of deviations of the geometrical shape of a riblet. Mandatory requirements, such as minimum intensity and light polarization, are obtained by means of detailed inspection of the optical response of the riblet using ray and wave optics; the impact of wavelength is studied. Novel measures for analyzing the riblet shape without the necessity of a measurement with a reference sample are derived; reference values for an ideal riblet structure obtained with the optical riblet sensor are given. The application of a low-cost, frequency-doubled Nd:YVO₄ laser pointer sufficient to serve as a reliable laser source in an appropriate optical riblet sensor is discussed.
Optical Riblet Sensor: Beam Parameter Requirements for the Probing Laser Source
Tschentscher, Juliane; Hochheim, Sven; Brüning, Hauke; Brune, Kai; Voit, Kay-Michael; Imlau, Mirco
2016-01-01
Beam parameters of a probing laser source in an optical riblet sensor are studied by considering the high demands on a sensors’ precision and reliability for the determination of deviations of the geometrical shape of a riblet. Mandatory requirements, such as minimum intensity and light polarization, are obtained by means of detailed inspection of the optical response of the riblet using ray and wave optics; the impact of wavelength is studied. Novel measures for analyzing the riblet shape without the necessity of a measurement with a reference sample are derived; reference values for an ideal riblet structure obtained with the optical riblet sensor are given. The application of a low-cost, frequency-doubled Nd:YVO4 laser pointer sufficient to serve as a reliable laser source in an appropriate optical riblet sensor is discussed. PMID:27043567
Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John
2011-06-01
The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P < .05). No difference was observed between the reference values and the LV parameters estimated by the entire slice set or a sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Modeling and monitoring of tooth fillet crack growth in dynamic simulation of spur gear set
NASA Astrophysics Data System (ADS)
Guilbault, Raynald; Lalonde, Sébastien; Thomas, Marc
2015-05-01
This study integrates a linear elastic fracture mechanics analysis of the tooth fillet crack propagation into a nonlinear dynamic model of spur gear sets. An original formulation establishes the rigidity of sound and damaged teeth. The formula incorporates the contribution of the flexible gear body and real crack trajectories in the fillet zone. The work also develops a KI prediction formula. A validation of the equation estimates shows that the predicted KI are in close agreement with published numerical and experimental values. The representation also relies on the Paris-Erdogan equation completed with crack closure effects. The analysis considers that during dN fatigue cycles, a harmonic mean of ΔK assures optimal evaluations. The paper evaluates the influence of the mesh frequency distance from the resonances of the system. The obtained results indicate that while the dependence may demonstrate obvious nonlinearities, the crack progression rate increases with a mesh frequency augmentation. The study develops a tooth fillet crack propagation detection procedure based on residual signals (RS) prepared in the frequency domain. The proposed approach accepts any gear conditions as reference signature. The standard deviation and mean values of the RS are evaluated as gear condition descriptors. A trend tracking of their responses obtained from a moving linear regression completes the analysis. Globally, the results show that, regardless of the reference signal, both descriptors are sensitive to the tooth fillet crack and sharply react to tooth breakage. On average, the mean value detected the crack propagation after a size increase of 3.69 percent as compared to the reference condition, whereas the standard deviation required crack progressions of 12.24 percent. Moreover, the mean descriptor shows evolutions closer to the crack size progression.
Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.
Chagren, S; Tekaya, M Ben; Reguigui, N; Gharbi, F
2016-01-01
In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a "virtual" reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60-2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.
[Geographical distribution of the Serum creatinine reference values of healthy adults].
Wei, De-Zhi; Ge, Miao; Wang, Cong-Xia; Lin, Qian-Yi; Li, Meng-Jiao; Li, Peng
2016-11-20
To explore the relationship between serum creatinine (Scr) reference values in healthy adults and geographic factors and provide evidence for establishing Scr reference values in different regions. We collected 29 697 Scr reference values from healthy adults measured by 347 medical facilities from 23 provinces, 4 municipalities and 5 autonomous regions. We chose 23 geographical factors and analyzed their correlation with Scr reference values to identify the factors correlated significantly with Scr reference values. According to the Principal component analysis and Ridge regression analysis, two predictive models were constructed and the optimal model was chosen after comparison of the two model's fitting degree of predicted results and measured results. The distribution map of Scr reference values was drawn using the Kriging interpolation method. Seven geographic factors, including latitude, annual sunshine duration, annual average temperature, annual average relative humidity, annual precipitation, annual temperature range and topsoil (silt) cation exchange capacity were found to correlate significantly with Scr reference values. The overall distribution of Scr reference values featured a pattern that the values were high in the south and low in the north, varying consistently with the latitude change. The data of the geographic factors in a given region allows the prediction of the Scr values in healthy adults. Analysis of these geographical factors can facilitate the determination of the reference values specific to a region to improve the accuracy for clinical diagnoses.
Findlay, R P; Dimbylow, P J
2009-04-21
If an antenna is located close to a person, the electric and magnetic fields produced by the antenna will vary in the region occupied by the human body. To obtain a mean value of the field for comparison with reference levels, the Institute of Electrical and Electronic Engineers (IEEE) and International Commission on Non-Ionizing Radiation Protection (ICNIRP) recommend spatially averaging the squares of the field strength over the height the body. This study attempts to assess the validity and accuracy of spatial averaging when used for half-wave dipoles at frequencies between 65 MHz and 2 GHz and distances of lambda/2, lambda/4 and lambda/8 from the body. The differences between mean electric field values calculated using ten field measurements and that of the true averaged value were approximately 15% in the 600 MHz to 2 GHz range. The results presented suggest that the use of modern survey equipment, which takes hundreds rather than tens of measurements, is advisable to arrive at a sufficiently accurate mean field value. Whole-body averaged and peak localized SAR values, normalized to calculated spatially averaged fields, were calculated for the NORMAN voxel phantom. It was found that the reference levels were conservative for all whole-body SAR values, but not for localized SAR, particularly in the 1-2 GHz region when the dipole was positioned very close to the body. However, if the maximum field is used for normalization of calculated SAR as opposed to the lower spatially averaged value, the reference levels provide a conservative estimate of the localized SAR basic restriction for all frequencies studied.
Trujillo, Logan T.; Stanfield, Candice T.; Vela, Ruben D.
2017-01-01
Converging evidence suggests that human cognition and behavior emerge from functional brain networks interacting on local and global scales. We investigated two information-theoretic measures of functional brain segregation and integration—interaction complexity CI(X), and integration I(X)—as applied to electroencephalographic (EEG) signals and how these measures are affected by choice of EEG reference. CI(X) is a statistical measure of the system entropy accounted for by interactions among its elements, whereas I(X) indexes the overall deviation from statistical independence of the individual elements of a system. We recorded 72 channels of scalp EEG from human participants who sat in a wakeful resting state (interleaved counterbalanced eyes-open and eyes-closed blocks). CI(X) and I(X) of the EEG signals were computed using four different EEG references: linked-mastoids (LM) reference, average (AVG) reference, a Laplacian (LAP) “reference-free” transformation, and an infinity (INF) reference estimated via the Reference Electrode Standardization Technique (REST). Fourier-based power spectral density (PSD), a standard measure of resting state activity, was computed for comparison and as a check of data integrity and quality. We also performed dipole source modeling in order to assess the accuracy of neural source CI(X) and I(X) estimates obtained from scalp-level EEG signals. CI(X) was largest for the LAP transformation, smallest for the LM reference, and at intermediate values for the AVG and INF references. I(X) was smallest for the LAP transformation, largest for the LM reference, and at intermediate values for the AVG and INF references. Furthermore, across all references, CI(X) and I(X) reliably distinguished between resting-state conditions (larger values for eyes-open vs. eyes-closed). These findings occurred in the context of the overall expected pattern of resting state PSD. Dipole modeling showed that simulated scalp EEG-level CI(X) and I(X) reflected changes in underlying neural source dependencies, but only for higher levels of integration and with highest accuracy for the LAP transformation. Our observations suggest that the Laplacian-transformation should be preferred for the computation of scalp-level CI(X) and I(X) due to its positive impact on EEG signal quality and statistics, reduction of volume-conduction, and the higher accuracy this provides when estimating scalp-level EEG complexity and integration. PMID:28790884
Naturally occurring levels of elements in fishes as determined by PIXE and XRF methods
NASA Astrophysics Data System (ADS)
Tallandini, L.; Giacobini, F.; Turchetto, M.; Galassini, S.; Liu, Q. X.; Shao, H. R.; Moschini, G.; Moro, R.; Gialanella, G.; Ghermandi, G.; Cecchi, R.; Injuk, J.; Valković, V.
1989-04-01
Naturally occurring levels of S, Cl, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Br, Sb, Sr and Pb were measured in the gills, liver and muscles of fishes ( Zosterisessor ophiocephalus Pall) in the northwestern region of the Adriatic Sea. The overall performance of PIXE and XRF methods was tested by the analysis of standard reference materials. The mean concentration values for elements were calculated from the distribution of experimentally determined concentration values. The obtained data are discussed in the framework of metal metabolism and toxicology.
NASA Astrophysics Data System (ADS)
Kartashov, E. M.
1986-10-01
Analytical methods for solving boundary value problems for the heat conduction equation with heterogeneous boundary conditions on lines, on a plane, and in space are briefly reviewed. In particular, the method of dual integral equations and summator series is examined with reference to stationary processes. A table of principal solutions to dual integral equations and pair summator series is proposed which presents the known results in a systematic manner. Newly obtained results are presented in addition to the known ones.
1986-03-01
Directly from Sample Bid VI-16 Example 3 VI-16 Determining the Zero Price Qiantity Demanded VI-26 Summary VI -31 CHAPrER VII, THE DETERMINATION OF NED...While the standard deviation and variance are absolute measures of dispersion, a relative measure of dispersion can also be computed. This measure is...refers to the closeness of fit between the estimates obtained from Zli e and the true population value. The only way of being absolutely i: o-.iat the
Villalobos Reyes, Marjorie; Mederico, Maracelly; Paoli de Valeri, Mariela; Briceño, Yajaira; Zerpa, Yajaira; Gómez-Pérez, Roald; Camacho, Nolis; Martínez, José Luis; Valeri, Lenín; Arata-Bellabarba, Gabriela
2014-11-01
To obtain local reference values for blood lipids and blood pressure (BP), and to determine the prevalence of metabolic syndrome (MS) in children and adolescents from Mérida, Venezuela, and to compare results using local and international cut-off values. The study enrolled 916 participants of both sexes aged 9-18 years of age from educational institutions. Demographic, anthropometric, and BP data were collected. Fasting blood glucose and lipid profile were measured. Percentile distribution of lipid and BP values was done by age group and sex. Prevalence of MS was estimated based on the NCEP-ATPIII classification (as modified by Cook et al.) and the classification of the International Diabetes Federation, using percentiles of Mérida and the USA as cut-off points. Agreement between both classifications was estimated using the kappa test (κ). Prevalence of MS was 2.2% by Cook-Merida percentiles, as compared to 1.8% by Cook-USA percentiles, a moderate agreement (κ=0.54). Agreement between Cook et al. and IDF using Merida percentiles was weak (κ=0.28). There was a higher frequency of abdominal obesity, hypertriglyceridemia and hypertension, and a lower frequency of low HDL-C using Mérida percentiles. The risk (odds ratio) of having MS is greater if abdominal obesity exists (OR: 98.63, CI: 22.45-433.35, p=0.0001). MS was significantly more common in obese subjects (18.3%, p=0.0001). Prevalence of MS in this sample of children and adolescents was 2.2%. Lipid and BP values were lower in Venezuelan as compared to US, European, and Asian children and adolescents, and similar to those in Latin-American references. Own reference values are required for accurate diagnosis of MS, as well as a worldwide consensus on its diagnostic criteria. Copyright © 2014 SEEN. Published by Elsevier Espana. All rights reserved.
Zhang, Su-jing; Luo, Ru-xin; Ma, Dong; Zhuo, Xian-yi
2016-04-01
To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.
NASA Astrophysics Data System (ADS)
Wang, Qian; Gao, Jinghuai
2018-02-01
As a powerful tool for hydrocarbon detection and reservoir characterization, the quality factor, Q, provides useful information in seismic data processing and interpretation. In this paper, we propose a novel method for Q estimation. The generalized seismic wavelet (GSW) function was introduced to fit the amplitude spectrum of seismic waveforms with two parameters: fractional value and reference frequency. Then we derive an analytical relation between the GSW function and the Q factor of the medium. When a seismic wave propagates through a viscoelastic medium, the GSW function can be employed to fit the amplitude spectrum of the source and attenuated wavelets, then the fractional values and reference frequencies can be evaluated numerically from the discrete Fourier spectrum. After calculating the peak frequency based on the obtained fractional value and reference frequency, the relationship between the GSW function and the Q factor can be built by the conventional peak frequency shift method. Synthetic tests indicate that our method can achieve higher accuracy and be more robust to random noise compared with existing methods. Furthermore, the proposed method is applicable to different types of source wavelet. Field data application also demonstrates the effectiveness of our method in seismic attenuation and the potential in the reservoir characteristic.
Surgical hand disinfection with a propanol-based hand rub: equivalence of shorter application times.
Kampf, G; Ostermeyer, C; Heeg, P
2005-04-01
The aim of this study was to determine the efficacy of a propanol-based hand rub at application times shorter than 3 min. The bacterial pre-value was obtained from the finger tips (prEN 12791). Subjects treated their hands with the reference procedure (n-propanol, 60%) for 3 min or the product (crossover design). Sterillium was applied for 3, 2, 1.5 and 1 min. Four other preparations were tested for 1 min. Post-values (immediate effect) were taken from one hand, and the other hand was gloved for 3h. After the gloves were removed, the second post-value was taken (sustained effect). Sterillium was more effective than the reference procedure at 3, 2 and 1.5 min (immediate and sustained effect). The immediate effect after 1 min was significantly lower [mean log(10) reduction factor (RF): 1.91+/-0.90 vs. 2.52+/-0.95; P=0.001], whereas the sustained effect was not (mean RF: 1.81+/-1.06 vs. 2.05+/-1.14; P=0.204). All other preparations failed the efficacy requirement at 1 min for both the immediate and sustained effect. Using 2 x 3 mL Sterillium for a total of 1.5 min for surgical hand disinfection was at least as effective as the 3-min reference disinfection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simbeck, D.J.
1997-06-01
Reference toxicant testing using juvenile freshwater mussels was conducted as part of the CR-ERP biomonitoring study of Clinch River sediments to assess the sensitivity of test organisms and the overall performance of the test. Tests were conducted using moderately hard synthetic water spiked with known concentrations of copper as copper sulfate. Two different foods, phytoplankton and YCT-Selenastrum (YCT-S), were tested in side by side tests to compare food quality. Toxicity testing of copper sulfate reference toxicant was conducted from July 6-15, 1993. The organisms used for testing were juvenile fresh-water mussels (Anodonta imbecillis). Results from this test showed LC{sub 50}more » values of 0.97 and 0.84 mg Cu/L for phytoplankton and YCT-S, respectively. Previously obtained values for phytoplankton tests are 2.02 and 1.12 mg Cu/L. Too few tests have been conducted with copper as the toxicant to determine a normal range of values. Although significant reduction in growth, compared to the phytoplankton control, was seen in all treatments, including the YCT-S Control, the consequence of this observation has not been established. Ninety-day testing of juvenile mussels exhibited large variations in growth within treatment and replicate groups.« less
Zuliani, Tea; Milačič, Radmila; Ščančar, Janez
2012-05-01
The characterisation of a laboratory quality control material (QCM) for dibutyltin (DBT) and tributyltin (TBT) in sewage sludge is described. The reference values were determined by the use of two different types of isotope-dilution mass spectrometry: gas chromatography-mass spectrometry and gas chromatography-inductively coupled plasma mass spectrometry. To avoid possible analytical errors such as non-quantitative extraction and species degradation during sample preparation, different extraction methods were tested (microwave- and ultrasound-assisted extraction and mechanical stirring). The reference values were based on the unweighted means of results from the homogenisation and characterisation studies. The reference values obtained were 1,553 ± 87 and 534 ± 38 ng Sn g(-1) for DBT and TBT, respectively. In the uncertainty budget estimation, the sample inhomogeneity and between-method imprecision were taken into account. The concentrations of DBT and TBT in QCM are similar to those in the harbour sediment certified reference material PACS-2. Likewise, the levels of DBT and TBT are in the range of these compounds normally present in sewage sludge worldwide. In the future, the QCM will be used for an intercomparison study on DBT and TBT in sewage sludge, and as a day-to-day QCM during studies concerning the application of sewage sludge as an additive to artificial soil or as a raw material in civil engineering construction.
Certification of reference materials for the determination of alkylphenols.
Hanari, Nobuyasu; Ishikawa, Keiichiro; Shimizu, Yoshitaka; Otsuka, Satoko; Iwasawa, Ryoko; Fujiki, Naomi; Numata, Masahiko; Yarita, Takashi; Kato, Kenji
2015-04-01
Certified reference materials (CRMs) are playing an increasingly important role in national and international standardizing activities. In Japan, primary standard solutions for analyses of endocrine disrupters are supplied under the national standards dissemination system named the Japan Calibration Service System (JCSS). For the traceability on reference materials used for preparation of the primary standard solutions based on the JCSS, the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed and certified high-purity reference materials of alkylphenols as NMIJ CRMs, such as 4-n-nonylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-tert-butylphenol, and 2,4-dichlorophenol. Thereafter, it is essential to determine the alkylphenols by using these solutions based on the JCSS for environmental monitoring and risk assessments because analytical values obtained by using the solutions can ensure the reliability and traceability of the chemical analyses.
Validation of 2 commercial Neospora caninum antibody enzyme linked immunosorbent assays
Wu, John T.Y.; Dreger, Sally; Chow, Eva Y.W.; Bowlby, Evelyn E.
2002-01-01
Abstract This is a validation study of 2 commercially available enzyme linked immunosorbent assays (ELISA) for the detection of antibodies against Neospora caninum in bovine serum. The results of the reference sera (n = 30) and field sera from an infected beef herd (n = 150) were tested by both ELISAs and the results were compared statistically. When the immunoblotting results of the reference bovine sera were compared to the ELISA results, the same identity score (96.67%) and kappa values (K) (0.93) were obtained for both ELISAs. The sensitivity and specificity values for the IDEXX test were 100% and 93.33% respectively. For the Biovet test 93.33% and 100% were obtained. The corresponding positive (PV+) and negative predictive (PV−) values for the 2 assays were 93.75% and 100% (IDEXX), and 100% and 93.75% (Biovet). In the 2nd study, competitive inhibition ELISA (c-ELISA) results on bovine sera from an infected herd were compared to the 2 sets of ELISA results. The identity scores of the 2 ELISAs were 98% (IDEXX) and 97.33% (Biovet). The K values calculated were 0.96 (IDEXX) and 0.95 (Biovet). For the IDEXX test the sensitivity and specificity were 97.56% and 98.53%, whereas for the Biovet assay 95.12% and 100% were recorded, respectively. The corresponding PV+ and PV− values were 98.77% and 97.1% (IDEXX), and 100% and 94.44% (Biovet). Our validation results showed that the 2 ELISAs worked equally well and there was no statistically significant difference between the performance of the 2 tests. Both tests showed high reproducibility, repeatability and substantial agreement with results from 2 other laboratories. A quality assurance based on the requirement of the ISO/IEC 17025 standards has been adopted throughout this project for test validation procedures. PMID:12418782
Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.
Mozaffari, A A; Samadieh, H
2013-09-01
To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.
Miller, Robert; Stalder, Tobias; Jarczok, Marc; Almeida, David M.; Badrick, Ellena; Bartels, Meike; Boomsma, Dorret I.; Coe, Christopher L.; Dekker, Marieke C. J.; Donzella, Bonny; Fischer, Joachim E.; Gunnar, Megan R.; Kumari, Meena; Lederbogen, Florian; Oldehinkel, Albertine J.; Power, Christine; Rosmalen, Judith G.; Ryff, Carol D.; Subramanian, S V; Tiemeier, Henning; Watamura, Sarah E.; Kirschbaum, Clemens
2016-01-01
Diurnal salivary cortisol profiles are valuable indicators of adrenocortical functioning in epidemiological research and clinical practice. However, normative reference values derived from a large number of participants and across a wide age range are still missing. To fill this gap, data were compiled from 15 independently conducted field studies with a total of 104,623 salivary cortisol samples obtained from 18,698 unselected individuals (mean age: 48.3 years, age range: 0.5 to 98.5 years, 39% females). Besides providing a descriptive analysis of the complete dataset, we also performed mixed-effects growth curve modeling of diurnal salivary cortisol (i.e., 1 to 16 hours after awakening). Cortisol decreased significantly across the day and was influenced by both, age and sex. Intriguingly, we also found a pronounced impact of sampling season with elevated diurnal cortisol in spring and decreased levels in autumn. However, the majority of variance was accounted for by between-participant and between-study variance components. Based on these analyses, reference ranges (LC/MS-MS calibrated) for cortisol concentrations in saliva were derived for different times across the day, with more specific reference ranges generated for males and females in different age categories. This integrative summary provides important reference values on salivary cortisol to aid basic scientists and clinicians in interpreting deviations from the normal diurnal cycle. PMID:27448524
Influence of structural parameters of deep groove ball bearings on vibration
NASA Astrophysics Data System (ADS)
Yu, Guangwei; Wu, Rui; Xia, Wei
2018-04-01
Taking 6201 bearing as the research object, a dynamic model of 4 degrees of freedom is established to solve the vibration characteristics such as the displacement, velocity and acceleration of deep groove ball bearings by MATLAB and Runge-Kutta method. By calculating the theoretical value of the frequency of the rolling element passing through the outer ring and the simulation value of the model, it can be known that the theoretical calculation value and the simulation value have good consistency. By the experiments, the measured values and simulation values are consistent. Using the mathematical model, the effect of structural parameters on vibration is obtained. The method in the paper is testified to be feasible and the results can be used as references for the design, manufacturing and testing of deep groove ball bearings.
Reference set design for relational modeling of fuzzy systems
NASA Astrophysics Data System (ADS)
Lapohos, Tibor; Buchal, Ralph O.
1994-10-01
One of the keys to the successful relational modeling of fuzzy systems is the proper design of fuzzy reference sets. This has been discussed throughout the literature. In the frame of modeling a stochastic system, we analyze the problem numerically. First, we briefly describe the relational model and present the performance of the modeling in the most trivial case: the reference sets are triangle shaped. Next, we present a known fuzzy reference set generator algorithm (FRSGA) which is based on the fuzzy c-means (Fc-M) clustering algorithm. In the second section of this chapter we improve the previous FRSGA by adding a constraint to the Fc-M algorithm (modified Fc-M or MFc-M): two cluster centers are forced to coincide with the domain limits. This is needed to obtain properly shaped extreme linguistic reference values. We apply this algorithm to uniformly discretized domains of the variables involved. The fuzziness of the reference sets produced by both Fc-M and MFc-M is determined by a parameter, which in our experiments is modified iteratively. Each time, a new model is created and its performance analyzed. For certain algorithm parameter values both of these two algorithms have shortcomings. To eliminate the drawbacks of these two approaches, we develop a completely new generator algorithm for reference sets which we call Polyline. This algorithm and its performance are described in the last section. In all three cases, the modeling is performed for a variety of operators used in the inference engine and two defuzzification methods. Therefore our results depend neither on the system model order nor the experimental setup.
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
Pansini, Vittorio; Monnet, Aurélien; Salleron, Julia; Hardouin, Pierre; Cortet, Bernard; Cotten, Anne
2014-02-01
To evaluate in a healthy population normal spectroscopic fat content (FC) values of the hip bone marrow and to assess the influence of age and sex on bone marrow conversion. Eighty volunteers (40 men; 40 women; ages: 20-60 years; divided into four consecutive groups) underwent acetabulum, femoral head, femoral neck, greater trochanter, and diaphysis localized (1) H MR spectroscopy. FC values of each anatomical site were obtained according to the following formula: Fat content = CH2 /(CH2 + Water)*100. To assess bone marrow conversion, a spectroscopic conversion index (SCI) was calculated as FC neck/FC greater trochanter. FC values showed a gradient as follows: greater trochanter > femoral head > femoral neck > diaphysis > acetabulum in every age group both in men and in women. SCI increased with age both in men and women, showing lower values in women for every age group. We obtained normal spectroscopic FC values from different areas of the hip, according to age and sex. These values may be used as reference values to evaluate, by the means of (1) H MR spectroscopy, pathological conditions affecting hip bone marrow. Copyright © 2013 Wiley Periodicals, Inc.
Katja — the 24th week of virtual pregnancy for dosimetric calculations
NASA Astrophysics Data System (ADS)
Becker, Janine; Zankl, Maria; Fill, Ute; Hoeschen, Christoph
2008-01-01
Virtual human models, a.k.a. voxel models, are currently the
Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code.
Yoriyaz, H; dos Santos, A; Stabin, M G; Cabezas, R
2000-07-01
A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body. The present technique shows the capability to build a patient-specific phantom with tomography data (a voxel-based phantom) for the simulation of radiation transport and energy deposition using Monte Carlo methods such as in the MCNP-4B code. MCNP-4B absorbed fractions for photons in the mathematical phantom of Snyder et al. agreed well with reference values. Results obtained through radiation transport simulation in the voxel-based phantom, in general, agreed well with reference values. Considerable discrepancies, however, were found in some cases due to two major causes: differences in the organ masses between the phantoms and the occurrence of organ overlap in the voxel-based phantom, which is not considered in the mathematical phantom.
Systems and methods for predicting materials properties
Ceder, Gerbrand; Fischer, Chris; Tibbetts, Kevin; Morgan, Dane; Curtarolo, Stefano
2007-11-06
Systems and methods for predicting features of materials of interest. Reference data are analyzed to deduce relationships between the input data sets and output data sets. Reference data includes measured values and/or computed values. The deduced relationships can be specified as equations, correspondences, and/or algorithmic processes that produce appropriate output data when suitable input data is used. In some instances, the output data set is a subset of the input data set, and computational results may be refined by optionally iterating the computational procedure. To deduce features of a new material of interest, a computed or measured input property of the material is provided to an equation, correspondence, or algorithmic procedure previously deduced, and an output is obtained. In some instances, the output is iteratively refined. In some instances, new features deduced for the material of interest are added to a database of input and output data for known materials.
Towards a new tool for the evaluation of the quality of ultrasound compressed images.
Delgorge, Cécile; Rosenberger, Christophe; Poisson, Gérard; Vieyres, Pierre
2006-11-01
This paper presents a new tool for the evaluation of ultrasound image compression. The goal is to measure the image quality as easily as with a statistical criterion, and with the same reliability as the one provided by the medical assessment. An initial experiment is proposed to medical experts and represents our reference value for the comparison of evaluation criteria. Twenty-one statistical criteria are selected from the literature. A cumulative absolute similarity measure is defined as a distance between the criterion to evaluate and the reference value. A first fusion method based on a linear combination of criteria is proposed to improve the results obtained by each of them separately. The second proposed approach combines different statistical criteria and uses the medical assessment in a training phase with a support vector machine. Some experimental results are given and show the benefit of fusion.
NASA Astrophysics Data System (ADS)
Schlattl, H.; Zankl, M.; Petoussi-Henss, N.
2007-04-01
A new series of organ equivalent dose conversion coefficients for whole body external photon exposure is presented for a standardized couple of human voxel models, called Rex and Regina. Irradiations from broad parallel beams in antero-posterior, postero-anterior, left- and right-side lateral directions as well as from a 360° rotational source have been performed numerically by the Monte Carlo transport code EGSnrc. Dose conversion coefficients from an isotropically distributed source were computed, too. The voxel models Rex and Regina originating from real patient CT data comply in body and organ dimensions with the currently valid reference values given by the International Commission on Radiological Protection (ICRP) for the average Caucasian man and woman, respectively. While the equivalent dose conversion coefficients of many organs are in quite good agreement with the reference values of ICRP Publication 74, for some organs and certain geometries the discrepancies amount to 30% or more. Differences between the sexes are of the same order with mostly higher dose conversion coefficients in the smaller female model. However, much smaller deviations from the ICRP values are observed for the resulting effective dose conversion coefficients. With the still valid definition for the effective dose (ICRP Publication 60), the greatest change appears in lateral exposures with a decrease in the new models of at most 9%. However, when the modified definition of the effective dose as suggested by an ICRP draft is applied, the largest deviation from the current reference values is obtained in postero-anterior geometry with a reduction of the effective dose conversion coefficient by at most 12%.
Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi
2014-01-20
Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV <1%. A certified reference material (CRM) of lipids in frozen human serum was used to verify the accuracy of the measurement. The obtained values for both triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation <0.4% from the certified values. The relative expanded uncertainties were also comparable with the uncertainties associated with the certified values of the CRM. The validated procedure was used in an External Quality Assessment (EQA) Program organized by our laboratory to establish the assigned values for triglycerides and total glycerides.
Biometric Subject Verification Based on Electrocardiographic Signals
NASA Technical Reports Server (NTRS)
Dusan, Sorin V. (Inventor); Jorgensen, Charles C. (Inventor)
2014-01-01
A method of authenticating or declining to authenticate an asserted identity of a candidate-person. In an enrollment phase, a reference PQRST heart action graph is provided or constructed from information obtained from a plurality of graphs that resemble each other for a known reference person, using a first graph comparison metric. In a verification phase, a candidate-person asserts his/her identity and presents a plurality of his/her heart cycle graphs. If a sufficient number of the candidate-person's measured graphs resemble each other, a representative composite graph is constructed from the candidate-person's graphs and is compared with a composite reference graph, for the person whose identity is asserted, using a second graph comparison metric. When the second metric value lies in a selected range, the candidate-person's assertion of identity is accepted.
Reference Values for Cardiorespiratory Fitness and Incidence of Type 2 Diabetes
Kawakami, Ryoko; Sawada, Susumu S.; Matsushita, Munehiro; Okamoto, Takashi; Tsukamoto, Koji; Higuchi, Mitsuru; Miyachi, Motohiko
2014-01-01
Background In “Physical Activity Reference for Health Promotion 2013” the Japan Ministry of Health, Labour and Welfare publication gives reference values for cardiorespiratory fitness (CRF) required for good health. We examined the associations between the CRF reference values and incidence of type 2 diabetes. Methods This prospective cohort study enrolled 4633 nondiabetic Japanese men aged 20 to 39 years at baseline. CRF was measured using the cycle ergometer test, and maximal oxygen uptake was estimated. On the basis of the CRF reference value, participants were classified into 2 groups: those with values less than the reference value (under-RV) and those with values equal to or greater than reference value (over-RV). Hazard ratios (HRs) and 95% CIs for incident type 2 diabetes were estimated using a Cox proportional hazards model. Results A total of 266 participants developed type 2 diabetes during the 14 years of follow-up. As compared with the under-RV group, the over-RV group had a significantly lower multivariable-adjusted HR for type 2 diabetes (HR 0.67; 95% CI, 0.51–0.89). In receiver operating characteristic analysis, the optimal CRF cut-off value for predicting incident type 2 diabetes was 10.8 metabolic equivalents (sensitivity, 0.64; specificity, 0.64), which was close to the CRF reference value of 11.0 metabolic equivalents. Conclusions The reference CRF value appears to be reasonably valid for prevention of type 2 diabetes, especially among Japanese men younger than 40 years. Development of type 2 diabetes can be prevented by maintaining a CRF level above the reference value. PMID:24240630
Peixoto, Alberto Borges; Caldas, Taciana Mara Rodrigues da Cunha; Martins, Wellington P; Da Silva Costa, Fabricio; Araujo Júnior, Edward
2016-10-01
To establish reference values for the amniotic fluid index (AFI) measurement between 26w0d and 41w6d of gestation in a Brazilian population. We performed a cross-sectional study with 1984 low-risk singleton pregnant women between 26w0d and 41w6d of gestation. AFI was measured according to the technique proposed by Phelan et al. Maternal abdomen was divided into four quadrants using the umbilicus and linea nigra as landmarks. Single vertical pocket in each quadrant was measured and the AFI was generated by the sum of these four values without umbilical cord or fetal parts. All ultrasound exams were performed by only two experienced examiners. AFI was expressed as median, interquartile range, mean and ranges in each gestational age (GA) interval. Polynomial regressions were performed to obtain the best fit with adjustment by the determination coefficient (R(2)). Mean of AFI ranged from 14.0 ± 4.1 cm (range, 9.7-14.0) at 26w0d to 8.3 ± 4.7 cm (range, 1.9-16.5) at 41w6d, respectively. The best polynomial regression fit curve was a first-degree: AFI = 16.29-0.125*GA (R(2) = 0.01). According the scatterplot, AFI values practically did not vary with advancing GA. Reference values for the AFI measurement between 26w0d and 41w6d of gestation in a low-risk Brazilian population were established.
Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.
Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W
2016-02-26
Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.
Olsen, Timothy W.
2008-01-01
Purpose To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Methods Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Results Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. Conclusions The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores. PMID:19277247
Riondato, J; Vanhaecke, F; Moens, L; Dams, R
2001-07-01
In the framework of an international certification campaign, sector-field inductively coupled plasma mass spectrometry (sector-field ICP-MS) was used for the accurate determination of the rare earth elements in five candidate reference materials: aquatic plant, calcareous soil, mussel tissue, river sediment, and tuna muscle. All samples were taken into solution by use of microwave-assisted or mixed microwave-assisted / open beaker acid digestion. Subsequently, the samples were appropriately diluted and subjected to ICP-MS analysis. Except for Sc, all the elements involved were determined at low mass resolution (R = 300). For Sc, application of a higher resolution setting (R = 3,000) was required to separate the analyte signal from those of several molecular ions which gave rise to spectral overlap at low mass resolution. Some of the heavier REE can also suffer from spectral overlap attributed to the occurrence of oxide ions (MO+) of the lighter REE and Ba. This spectral overlap could be successfully overcome by mathematical correction. Matrix effects were overcome by use of two carefully selected internal standards, such that external calibration could be used. On each occasion, a geological reference material was analyzed as a quality-control sample and the reliability of all results obtained was additionally checked by means of chondrite normalization. For tuna muscle the content of all REE was below the limit of detection. For calcareous soil and river sediment, low to sub microg g(-1) values were observed, whereas the REE content of aquatic plant and mussel tissue was considerably lower (low to sub ng g(-1)). Overall, the results obtained were in excellent agreement with the average values, calculated on the basis of all "accepted" values, obtained in different laboratories using different techniques.
Olsen, Timothy W
2008-01-01
To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores.
Makretsov, Nikita; Gilks, C Blake; Alaghehbandan, Reza; Garratt, John; Quenneville, Louise; Mercer, Joel; Palavdzic, Dragana; Torlakovic, Emina E
2011-07-01
External quality assurance and proficiency testing programs for breast cancer predictive biomarkers are based largely on traditional ad hoc design; at present there is no universal consensus on definition of a standard reference value for samples used in external quality assurance programs. To explore reference values for estrogen receptor and progesterone receptor immunohistochemistry in order to develop an evidence-based analytic platform for external quality assurance. There were 31 participating laboratories, 4 of which were previously designated as "expert" laboratories. Each participant tested a tissue microarray slide with 44 breast carcinomas for estrogen receptor and progesterone receptor and submitted it to the Canadian Immunohistochemistry Quality Control Program for analysis. Nuclear staining in 1% or more of the tumor cells was a positive score. Five methods for determining reference values were compared. All reference values showed 100% agreement for estrogen receptor and progesterone receptor scores, when indeterminate results were excluded. Individual laboratory performance (agreement rates, test sensitivity, test specificity, positive predictive value, negative predictive value, and κ value) was very similar for all reference values. Identification of suboptimal performance by all methods was identical for 30 of 31 laboratories. Estrogen receptor assessment of 1 laboratory was discordant: agreement was less than 90% for 3 of 5 reference values and greater than 90% with the use of 2 other reference values. Various reference values provide equivalent laboratory rating. In addition to descriptive feedback, our approach allows calculation of technical test sensitivity and specificity, positive and negative predictive values, agreement rates, and κ values to guide corrective actions.
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, Timothy; Bode, Bruce W.; Christiansen, Mark P.; Klaff, Leslie J.
2015-01-01
Abstract Introduction: The purpose of the study was to evaluate the performance and usability of the FreeStyle® Libre™ Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. Materials and Methods: Seventy-two study participants with type 1 or type 2 diabetes were enrolled by four U.S. clinical sites. A sensor was inserted on the back of each upper arm for up to 14 days. Three factory-only calibrated sensor lots were used in the study. Sensor glucose measurements were compared with capillary blood glucose (BG) results (approximately eight per day) obtained using the BG meter built into the reader (BG reference) and with the YSI analyzer (Yellow Springs Instrument, Yellow Springs, OH) reference tests at three clinic visits (32 samples per visit). Sensor readings were masked to the participants. Results: The accuracy of the results was demonstrated against capillary BG reference values, with 86.7% of sensor results within Consensus Error Grid Zone A. The percentage of readings within Consensus Error Grid Zone A on Days 2, 7, and 14 was 88.4%, 89.2%, and 85.2%, respectively. The overall mean absolute relative difference was 11.4%. The mean lag time between sensor and YSI reference values was 4.5±4.8 min. Sensor accuracy was not affected by factors such as body mass index, age, type of diabetes, clinical site, insulin administration, or hemoglobin A1c. Conclusions: Interstitial glucose measurements with the FreeStyle Libre system were found to be accurate compared with capillary BG reference values, with accuracy remaining stable over 14 days of wear and unaffected by patient characteristics. PMID:26171659
Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric
2016-08-01
Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System.
Bailey, Timothy; Bode, Bruce W; Christiansen, Mark P; Klaff, Leslie J; Alva, Shridhara
2015-11-01
The purpose of the study was to evaluate the performance and usability of the FreeStyle(®) Libre™ Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. Seventy-two study participants with type 1 or type 2 diabetes were enrolled by four U.S. clinical sites. A sensor was inserted on the back of each upper arm for up to 14 days. Three factory-only calibrated sensor lots were used in the study. Sensor glucose measurements were compared with capillary blood glucose (BG) results (approximately eight per day) obtained using the BG meter built into the reader (BG reference) and with the YSI analyzer (Yellow Springs Instrument, Yellow Springs, OH) reference tests at three clinic visits (32 samples per visit). Sensor readings were masked to the participants. The accuracy of the results was demonstrated against capillary BG reference values, with 86.7% of sensor results within Consensus Error Grid Zone A. The percentage of readings within Consensus Error Grid Zone A on Days 2, 7, and 14 was 88.4%, 89.2%, and 85.2%, respectively. The overall mean absolute relative difference was 11.4%. The mean lag time between sensor and YSI reference values was 4.5±4.8 min. Sensor accuracy was not affected by factors such as body mass index, age, type of diabetes, clinical site, insulin administration, or hemoglobin A1c. Interstitial glucose measurements with the FreeStyle Libre system were found to be accurate compared with capillary BG reference values, with accuracy remaining stable over 14 days of wear and unaffected by patient characteristics.
The Neurobiology of Reference-Dependent Value Computation
De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.
2009-01-01
A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780
Reference values for 27 clinical chemistry tests in 70-year-old males and females.
Carlsson, Lena; Lind, Lars; Larsson, Anders
2010-01-01
Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.
The use of reference materials in quality assurance programmes in food microbiology laboratories.
In't Veld, P H
1998-11-24
Nine different reference materials (RMs) for use in food and water microbiology have been developed with the support of the European Commission (EC). The production process of RMs is based on spray drying bacteria suspended in milk. The highly contaminated milk powder (HCMP) obtained is mixed with sterile milk powder to achieve the desired level of contamination and is subsequently filled into gelatine capsules. The HCMP may need to be stabilised by storage for more than a year before a stable RM can be prepared. The HCMP are mixed with sterile milk powder using a pestle and mortar in order to produce homogeneous RMs. For routine use of RMs Shewhart control charts can be produced. Based on log10 transformed counts, control limits are calculated. Rules for the interpretation of results facilitate the detection of out of control situations. Besides RMs there are also CRMs (Certified Reference Materials) that are certified by the EC Community Bureau of Reference (BCR) and are intended for occasional use. Based on the BCR certificate, user tables are produced presenting the 95% confidence limits for the number of capsules likely to be examined in practice. Also power analysis is made to indicate the minimum difference between the certified value and the observed geometric mean value in relation to the number of capsules examined.
A proposed International Geomagnetic Reference Field for 1965- 1985.
Peddie, N.W.; Fabiano, E.B.
1982-01-01
A set of spherical harmonic models describing the Earth's main magnetic field from 1965 to 1985 has been developed and is proposed as the next revision of the International Geomagnetic Reference Field (IGRF). A tenth degree and order spherical harmonic model of the main field was derived from Magsat data. A series of eighth degree and order spherical harmonic models of the secular variation of the main field was derived from magnetic observatory annual mean values. Models of the main field at 1965, 1970, 1975, and 1980 were obtained by extrapolating the main-field model using the secular variation models.-Authors spherical harmonic models Earth main magnetic field Magsat data
Charon/Pluto Mass Ratio Obtained with HST CCD Observations in 1991 and 1993
NASA Technical Reports Server (NTRS)
Null, George W.
1995-01-01
We have analyzed Hubble Space Telescope wide field camera observations of Pluto, Charon, and a reference star, acquired in 1991 and 1993, to observe Pluto's barycentric motion and determine the Charon/Pluto mass ratio, q = 0.1237 +/-0.0081, with 6.5% accuracy. Solution values for Charon orbital elements include the semimajor axis, a = 19662 +/-81 km; inclination, i = 96.57 +/-0.24 deg; eccentricity, e = 0.0072 +/-0.0067; longitude of periapsis, w = 2 +/-35 deg; and mean longitude, l = 123.58 +/-0.43 deg. These elements are referred to the J2000 Earth equator and equinox at epoch JED 2446600.5.
NASA Astrophysics Data System (ADS)
Demyanov, A. A.; Tsurko, A. A.
2017-01-01
In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000' respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Demyanov, A. A.; Tsurko, A. A.
2017-01-01
In the comparisons three Newtonian liquid samples were used with nominal values of 20 mm2/s 100 mm2/s and 1000 mm2/s ('20', '100' and '1000', respectively) at 20 °C. Each NMI presented results of measurements values kinematic viscosity samples, uncertainty and uncertainty budget. The purpose of these comparisons was confirmation of measurement and calibration capabilities (CMC) of the relevant NMI. As a reference the values of kinematic viscosity reference samples were taken as average values of measurement results obtained in the research laboratory of the national standards and research in the field of measurements of viscosity and density of the D I Mendeleev Institute for Metrology (VNIIM, RF), as a participant in international comparisons CCM.V-K1, BIPM. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Miyashita, Shin-ichi; Inagaki, Kazumi; Narukawa, Tomohiro; Zhu, Yanbei; Kuroiwa, Takayoshi; Hioki, Akiharu; Chiba, Koichi
2012-01-01
A certified reference material (CRM) for trace cadmium and other elements in brown rice flour was developed at the National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder after drying and frozen pulverization of fresh brown rice obtained from a Japanese domestic market. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), ICP high-resolution mass spectrometry, isotope-dilution ICP-MS, ICP optical emission spectrometry, and graphite-furnace atomic-absorption spectrometry. Property values were provided for six elements (Mn, Fe, Cu, Zn, As, and Cd). The concentration range of the property values was from 0.280 mg kg(-1) of As to 31.8 mg kg(-1) of Zn. The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, characterization, difference among analytical methods, dry-mass correction factor, and calibration standard. The range of the relative combined standard uncertainties was from 1.1% of Zn to 1.6% of As.
Helmeczi, Erick; Wang, Yong; Brindle, Ian D
2016-11-01
Short-wavelength infrared radiation has been successfully applied to accelerate the acid digestion of refractory rare-earth ore samples. Determinations were achieved with microwave plasma-atomic emission spectrometry (MP-AES) and dynamic reaction cell - inductively coupled plasma-mass spectrometry (DRC-ICP-MS). The digestion method developed was able to tackle high iron-oxide and silicate matrices using only phosphoric acid in a time frame of only 8min, and did not require perchloric or hydrofluoric acid. Additionally, excellent recoveries and reproducibilities of the rare earth elements, as well as uranium and thorium, were achieved. Digestions of the certified reference materials OREAS-465 and REE-1, with radically different mineralogies, delivered results that mirror those obtained by fusion processes. For the rare-earth CRM OKA-2, whose REE data are provisional, experimental data for the rare-earth elements were generally higher than the provisional values, often exceeding z-values of +2. Determined values for Th and U in this reference material, for which certified values are available, were in excellent agreement. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Grafarend, E. W.; Heck, B.; Knickmeyer, E. H.
1985-03-01
Various formulations of the geodetic fixed and free boundary value problem are presented, depending upon the type of boundary data. For the free problem, boundary data of type astronomical latitude, astronomical longitude and a pair of the triplet potential, zero and first-order vertical gradient of gravity are presupposed. For the fixed problem, either the potential or gravity or the vertical gradient of gravity is assumed to be given on the boundary. The potential and its derivatives on the boundary surface are linearized with respect to a reference potential and a reference surface by Taylor expansion. The Eulerian and Lagrangean concepts of a perturbation theory of the nonlinear geodetic boundary value problem are reviewed. Finally the boundary value problems are solved by Hilbert space techniques leading to new generalized Stokes and Hotine functions. Reduced Stokes and Hotine functions are recommended for numerical reasons. For the case of a boundary surface representing the topography a base representation of the solution is achieved by solving an infinite dimensional system of equations. This system of equations is obtained by means of the product-sum-formula for scalar surface spherical harmonics with Wigner 3j-coefficients.
A comparative evaluation of intraoral and extraoral digital impressions: An in vivo study.
Sason, Gursharan Kaur; Mistry, Gaurang; Tabassum, Rubina; Shetty, Omkar
2018-01-01
The accuracy of a dental impression is determined by two factors: "trueness" and "precision." The scanners used in dentistry are relatively new in market, and very few studies have compared the "precision" and "trueness" of intraoral scanner with the extraoral scanner. The aim of this study was to evaluate and compare accuracy of intraoral and extraoral digital impressions. Ten dentulous participants (male/female) aged 18-45 years with an asymptomatic endodontically treated mandibular first molars with adjacent teeth present were selected for this study. The prepared test tooth was measured using a digital Vernier caliper to obtain reference datasets. The tooth was then scanned using the intraoral scanner, and the extraoral scans were obtained using the casts made from the impressions. The datasets were divided into four groups and then statistically analyzed. The test tooth preparation was done, and dimples were made using a round diamond point on the bucco-occlusal, mesio-occlusal, disto-occlusal, and linguo-occlusal lines angles, and these were used to obtain reference datasets intraorally using a digital Vernier caliper. The test tooth was then scanned with the IO scanner (CS 3500, Carestream dental) thrice and also impressions were made using addition silicone impression material (3M™ ESPE) and dental casts were poured in Type IV dental stone (Kalrock-Kalabhai Karson India Pvt. Ltd., India) which were later scanned with the EO scanner (LAVA™ Scan ST Design system [3M™ ESPE]) thrice. The Datasets obtained from Intraoral and Extraoral scanner were exported to Dental Wings software and readings were obtained. Repeated measures ANOVA test was used to compare differences between the groups and independent t -test for comparison between the readings of intraoral and extraoral scanner. Least significant difference test was used for comparison between reference datasets with intraoral and extraoral scanner, respectively. A level of statistical significance of P < 0.05 was set. The precision values ranged from 20.7 to 33.35 μm for intraoral scanner and 19.5 to 37 μm for extraoral scanner. The mean deviations for intraoral scanner were 19.6 μm mesiodistally (MD) and 16.4 μm buccolingually (BL) and 24.0 μm MD and 22.5 μm BL for extraoral scanner. The mean values of the intraoral scanner (413 μm) for trueness were closest to the actual measurements (459 μm) than the extraoral scanner (396 μm). The intraoral scanner showed higher "precision" and "trueness" values when compared with the extraoral scanner.
The Logical Problem of Language Change.
1995-07-01
tribution Pi. For the most part we will assume in our simulations that this distribution is uniform on degree-0 ( unembedded ) sentences, exactly as in...following table provides the unembedded (degree- 0) sentences from each of the 8 grammars (languages) obtained by setting the 3 parameters of example 1 to di erent values. The languages are referred to as L1 through L8: 17 18
ERIC Educational Resources Information Center
Page, Randy M.; Lee, Ching-Mei; Miao, Nae-Fang
2004-01-01
This study compared consistency of age- and gender-specific self-reported height and weight and calculated body mass index among a sample of high school students in Taipei County, Taiwan to reference values for Taiwanese school-aged youth obtained through national studies. Taipei high school students provided self-reports of height and weight that…
A Status of NASA Rotorcraft Research
2009-09-01
approximate threefold range in the values of CP. It has been found useful in many cases to include additional independent variables and group...and improved rotorcraft. These needs include better analysis and better data. Many plans proposed for NASA rotorcraft research are discussed here, to...a successful active noise- control system include : obtaining a clean reference signal with minimal phase jitter; achieving a global reduction of
Pilot study on peptide purity—synthetic human C-peptide
NASA Astrophysics Data System (ADS)
Josephs, R. D.; Li, M.; Song, D.; Daireaux, A.; Choteau, T.; Stoppacher, N.; Westwood, S.; Wielgosz, R.; Xiao, P.; Liu, Y.; Gao, X.; Zhang, C.; Zhang, T.; Mi, W.; Quan, C.; Huang, T.; Li, H.; Melanson, J. E.; Ün, I.; Gören, A. C.; Quaglia, M.; Warren, J.
2017-01-01
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P55.2, was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM). Four Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of human C-peptide (hCP) present as the main component in the comparison sample for CCQM-P55.2. The comparison samples were prepared from synthetic human hCP purchased from a commercial supplier and used as provided without further treatment or purification. hCP was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of short (up to 5 kDa), non-cross-linked synthetic peptides/proteins. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used a quantitative nuclear magnetic resonance spectroscopy (qNMR) corrected for peptide impurities. Other participants provided results obtained by peptide impurity corrected amino acid analysis (PICAA) or elemental analysis (PICCHN). It was decided to assign reference values based on the KCRVs of CCQM-K115 for both the hCP mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the hCP purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the hCP mass fraction. In particular it allows participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most exhaustive and elaborate set of results is taken for the calculation of the reference value. The reference value for the peptide related impurity mass fractions of the material was 83.3 mg/g with a combined standard uncertainty of 1.5 mg/g. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in many cases only a very small number of impurities have been identified and quantified resulting in an underestimation of the peptide related impurity mass fractions. The reference value for the mass fraction of hCP for CCQM-KP55.2 is 801.8 mg/g with a corresponding combined standard uncertainty of 3.1 mg/g. Inspection of the degree of equivalence plots for CCQM-P55.2 for the mass fraction of hCP shows that three results agree with the reference value. Main text To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM.
Wu, Keke; Liu, Wenwen; Mar, Thithi; Liu, Yan; Wu, Yunfeng; Wang, Xifeng
2014-01-01
The bird cherry-oat aphid (Rhopalosiphum padi), an important pest of cereal crops, not only directly sucks sap from plants, but also transmits a number of plant viruses, collectively the yellow dwarf viruses (YDVs). For quantifying changes in gene expression in vector aphids, reverse transcription-quantitative polymerase chain reaction (RT-qPCR) is a touchstone method, but the selection and validation of housekeeping genes (HKGs) as reference genes to normalize the expression level of endogenous genes of the vector and for exogenous genes of the virus in the aphids is critical to obtaining valid results. Such an assessment has not been done, however, for R. padi and YDVs. Here, we tested three algorithms (GeNorm, NormFinder and BestKeeper) to assess the suitability of candidate reference genes (EF-1α, ACT1, GAPDH, 18S rRNA) in 6 combinations of YDV and vector aphid morph. EF-1α and ACT1 together or in combination with GAPDH or with GAPDH and 18S rRNA could confidently be used to normalize virus titre and expression levels of endogenous genes in winged or wingless R. padi infected with Barley yellow dwarf virus isolates (BYDV)-PAV and BYDV-GAV. The use of only one reference gene, whether the most stably expressed (EF-1α) or the least stably expressed (18S rRNA), was not adequate for obtaining valid relative expression data from the RT-qPCR. Because of discrepancies among values for changes in relative expression obtained using 3 regions of the same gene, different regions of an endogenous aphid gene, including each terminus and the middle, should be analyzed at the same time with RT-qPCR. Our results highlight the necessity of choosing the best reference genes to obtain valid experimental data and provide several HKGs for relative quantification of virus titre in YDV-viruliferous aphids. PMID:24810421
Muir, B; Rogers, D; McEwen, M
2012-07-01
When current dosimetry protocols were written, electron beam data were limited and had uncertainties that were unacceptable for reference dosimetry. Protocols for high-energy reference dosimetry are currently being updated leading to considerable interest in accurate electron beam data. To this end, Monte Carlo simulations using the EGSnrc user-code egs_chamber are performed to extract relevant data for reference beam dosimetry. Calculations of the absorbed dose to water and the absorbed dose to the gas in realistic ion chamber models are performed as a function of depth in water for cobalt-60 and high-energy electron beams between 4 and 22 MeV. These calculations are used to extract several of the parameters required for electron beam dosimetry - the beam quality specifier, R 50 , beam quality conversion factors, k Q and k R50 , the electron quality conversion factor, k' R50 , the photon-electron conversion factor, k ecal , and ion chamber perturbation factors, P Q . The method used has the advantage that many important parameters can be extracted as a function of depth instead of determination at only the reference depth as has typically been done. Results obtained here are in good agreement with measured and other calculated results. The photon-electron conversion factors obtained for a Farmer-type NE2571 and plane-parallel PTW Roos, IBA NACP-02 and Exradin A11 chambers are 0.903, 0.896, 0.894 and 0.906, respectively. These typically differ by less than 0.7% from the contentious TG-51 values but have much smaller systematic uncertainties. These results are valuable for reference dosimetry of high-energy electron beams. © 2012 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Zhang, Yufeng; Long, Man; Luo, Sida; Bao, Yu; Shen, Hanxia
2015-12-01
Transit route choice model is the key technology of public transit systems planning and management. Traditional route choice models are mostly based on expected utility theory which has an evident shortcoming that it cannot accurately portray travelers' subjective route choice behavior for their risk preferences are not taken into consideration. Cumulative prospect theory (CPT), a brand new theory, can be used to describe travelers' decision-making process under the condition of uncertainty of transit supply and risk preferences of multi-type travelers. The method to calibrate the reference point, a key parameter to CPT-based transit route choice model, determines the precision of the model to a great extent. In this paper, a new method is put forward to obtain the value of reference point which combines theoretical calculation and field investigation results. Comparing the proposed method with traditional method, it shows that the new method can promote the quality of CPT-based model by improving the accuracy in simulating travelers' route choice behaviors based on transit trip investigation from Nanjing City, China. The proposed method is of great significance to logical transit planning and management, and to some extent makes up the defect that obtaining the reference point is solely based on qualitative analysis.
Kos, Bor; Valič, Blaž; Kotnik, Tadej; Gajšek, Peter
2012-10-07
Induction heating equipment is a source of strong and nonhomogeneous magnetic fields, which can exceed occupational reference levels. We investigated a case of an induction tempering tunnel furnace. Measurements of the emitted magnetic flux density (B) were performed during its operation and used to validate a numerical model of the furnace. This model was used to compute the values of B and the induced in situ electric field (E) for 15 different body positions relative to the source. For each body position, the computed B values were used to determine their maximum and average values, using six spatial averaging schemes (9-285 averaging points) and two averaging algorithms (arithmetic mean and quadratic mean). Maximum and average B values were compared to the ICNIRP reference level, and E values to the ICNIRP basic restriction. Our results show that in nonhomogeneous fields, the maximum B is an overly conservative predictor of overexposure, as it yields many false positives. The average B yielded fewer false positives, but as the number of averaging points increased, false negatives emerged. The most reliable averaging schemes were obtained for averaging over the torso with quadratic averaging, with no false negatives even for the maximum number of averaging points investigated.
NASA Astrophysics Data System (ADS)
Shah, Amish P.
The need for improved patient-specificity of skeletal dose estimates is widely recognized in radionuclide therapy. Current clinical models for marrow dose are based on skeletal mass estimates from a variety of sources and linear chord-length distributions that do not account for particle escape into cortical bone. To predict marrow dose, these clinical models use a scheme that requires separate calculations of cumulated activity and radionuclide S values. Selection of an appropriate S value is generally limited to one of only three sources, all of which use as input the trabecular microstructure of an individual measured 25 years ago, and the tissue mass derived from different individuals measured 75 years ago. Our study proposed a new modeling approach to marrow dosimetry---the Paired Image Radiation Transport (PIRT) model---that properly accounts for both the trabecular microstructure and the cortical macrostructure of each skeletal site in a reference male radionuclide patient. The PIRT model, as applied within EGSnrc, requires two sets of input geometry: (1) an infinite voxel array of segmented microimages of the spongiosa acquired via microCT; and (2) a segmented ex-vivo CT image of the bone site macrostructure defining both the spongiosa (marrow, endosteum, and trabeculae) and the cortical bone cortex. Our study also proposed revising reference skeletal dosimetry models for the adult male cancer patient. Skeletal site-specific radionuclide S values were obtained for a 66-year-old male reference patient. The derivation for total skeletal S values were unique in that the necessary skeletal mass and electron dosimetry calculations were formulated from the same source bone site over the entire skeleton. We conclude that paired-image radiation-transport techniques provide an adoptable method by which the intricate, anisotropic trabecular microstructure of the skeletal site; and the physical size and shape of the bone can be handled together, for improved compilation of reference radionuclide S values. We also conclude that this comprehensive model for the adult male cancer patient should be implemented for use in patient-specific calculations for radionuclide dosimetry of the skeleton.
Validated age-specific reference values for CSF total protein levels in children.
Kahlmann, V; Roodbol, J; van Leeuwen, N; Ramakers, C R B; van Pelt, D; Neuteboom, R F; Catsman-Berrevoets, C E; de Wit, M C Y; Jacobs, B C
2017-07-01
To define age-specific reference values for cerebrospinal fluid (CSF) total protein levels for children and validate these values in children with Guillain-Barré syndrome (GBS), acute disseminated encephalomyelitis (ADEM) and multiple sclerosis (MS). Reference values for CSF total protein levels were determined in an extensive cohort of diagnostic samples from children (<18 year) evaluated at Erasmus Medical Center/Sophia Children's Hospital. These reference values were confirmed in children diagnosed with disorders unrelated to raised CSF total protein level and validated in children with GBS, ADEM and MS. The test results of 6145 diagnostic CSF samples from 3623 children were used to define reference values. The reference values based on the upper limit of the 95% CI (i.e. upper limit of normal) were for 6 months-2 years 0.25 g/L, 2-6 years 0.25 g/L, 6-12 years 0.28 g/L, 12-18 years 0.34 g/L. These reference values were confirmed in a subgroup of 378 children diagnosed with disorders that are not typically associated with increased CSF total protein. In addition, the CSF total protein levels in these children in the first 6 months after birth were highly variable (median 0.47 g/L, IQR 0.26-0.65). According to these new reference values, CSF total protein level was elevated in 85% of children with GBS, 66% with ADEM and 23% with MS. More accurate age-specific reference values for CSF total protein levels in children were determined. These new reference values are more sensitive than currently used values for diagnosing GBS and ADEM in children. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Vahabzadeh, Afshin; Vatanpour, Hossein; Dinarvand, Rasoul; Rajabzadeh, Ali; Salamzadeh, Jamshid; Mohammadzadeh, Mehdi
2017-01-01
The influence of company reputation or what is often referred to as corporate reputation on branding strategy and producing intangible asset for different industries has been researched in western countries, but there is a gap for the generalizability of findings to countries out of the United State and Europe. To establish the western researcher's external validity of theories in other countries and to obtain a better understanding of the influences of branding and company reputation on pharmaceutical business markets, the researchers applied this study for Iran, a country in the Middle East. The obtained results using SEM (by P.L.S. 2.0 software) showed a good relationship between value creation and brand differentiation (β =0.360 and t-value = 3.167), between corporate communication and brand differentiation (β = 0.022 and t-value = 3.668), and between strategic resources and brand differentiation (β = 0.289 and t-value = 2.247). This study is a pioneering attempt in Iran to measure the impact of corporate reputation on brand differentiation strategy.
vahabzadeh, Afshin; vatanpour, Hossein; dinarvand, Rasoul; rajabzadeh, Ali; salamzadeh, Jamshid; mohammadzadeh, Mehdi
2017-01-01
The influence of company reputation or what is often referred to as corporate reputation on branding strategy and producing intangible asset for different industries has been researched in western countries, but there is a gap for the generalizability of findings to countries out of the United State and Europe. To establish the western researcher’s external validity of theories in other countries and to obtain a better understanding of the influences of branding and company reputation on pharmaceutical business markets, the researchers applied this study for Iran, a country in the Middle East. The obtained results using SEM (by P.L.S. 2.0 software) showed a good relationship between value creation and brand differentiation (β =0.360 and t-value = 3.167), between corporate communication and brand differentiation (β = 0.022 and t-value = 3.668), and between strategic resources and brand differentiation (β = 0.289 and t-value = 2.247). This study is a pioneering attempt in Iran to measure the impact of corporate reputation on brand differentiation strategy. PMID:29552075
Calculating LOAEL/NOAEL uncertainty factors for wildlife species in ecological risk assessments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suedel, B.C.; Clifford, P.A.; Ludwig, D.F.
1995-12-31
Terrestrial ecological risk assessments frequently require derivation of NOAELs or toxicity reference values (TRVS) against which to compare exposure estimates. However, much of the available information from the literature is LOAELS, not NOAELS. Lacking specific guidance, arbitrary factors of ten are sometimes employed for extrapolating NOAELs from LOAELs. In this study, the scientific literature was searched to obtain chronic and subchronic studies reporting NOAEL and LOAEL data for wildlife and laboratory species. Results to date indicate a mean conversion factor of 4.0 ({+-} 2.61 S.D.), with a minimum of 1. 6 and a maximum of 10 for 106 studies acrossmore » several classes of compounds (I.e., metals, pesticides, volatiles, etc.). These data suggest that an arbitrary factor of 10 conversion factor is unnecessarily restrictive for extrapolating NOAELs from LOAELs and that a factor of 4--5 would be more realistic for deriving toxicity reference values for wildlife species. Applying less arbitrary and more realistic conversion factors in ecological risk assessments will allow for a more accurate estimate of NOAEL values for assessing risk to wildlife populations.« less
Hein, Sascha; Zangl, Michael
2016-01-01
The aim of this in vitro study was to investigate the color changes of human teeth caused by five different diffuser materials commonly used in dental photography, as well as software influence, and to confirm whether the use of a standardized gray reference card is effective in correcting these color changes during digital postproduction. Forty extracted human teeth were obtained from a specialized oral surgery practice in Cham, Germany. Five commonly used diffuser materials were chosen to be investigated, which included: polyethylene (PET), White Frost photographic paper, LumiQuest polyamide (nylon) material, 80 gsm white printing paper, and 3M linear polarizing filter sheet used for cross polarization. A digital single-lens reflex camera (Canon EOS 5D MKII) was used, together with a twin flash suitable for macrophotography (Canon MT-24EX Macro Twin Lite). Images were tethered into Adobe Lightroom CC using the RAW format. A standardized gray reference card (WhiBal, Michael Tapes Design) was used for exposure calibration and white balancing. Classic Color Me- ter software (Ricci Adams, version 1.6 (122)) was used to obtain CIE L*a*b* values of the specimens before and after white balancing and exposure correction. All diffusers caused visually perceivable color changes on the extracted teeth: White Frost (ΔE* 1.24; sd 0.47), 80 gsm printing paper (ΔE* 2.94; sd 0.35), LumiQuest polyamide (ΔE* 3.68; sd 0.54), PET (ΔE* 6.55; sd 0.41), and 3M linear polarizing filter sheet (ΔE* 7.58; sd 1.00). The use of a standardized gray reference card (WhiBal) could correct these values below the visually perceivable threshold: White Frost (ΔE* 0.58; sd 0.36), 80 gsm printing paper (ΔE* 0.93; sd 0.54), LumiQuest polyamide (ΔE* 0.66; sd 0.58), PET (ΔE* 0.59; sd 0.33), and 3M linear polarizing filter sheet (ΔE* 0.53; sd 0.42). The use of a standardized gray reference card with specified CIE L*a*b* values should be considered when diffusers are used in dental photography in order to reveal the color of preoperative situations (ie, shade documentation) and document postoperative results accurately.
Photosynthesis-related quantities for education and modeling.
Antal, Taras K; Kovalenko, Ilya B; Rubin, Andrew B; Tyystjärvi, Esa
2013-11-01
A quantitative understanding of the photosynthetic machinery depends largely on quantities, such as concentrations, sizes, absorption wavelengths, redox potentials, and rate constants. The present contribution is a collection of numbers and quantities related mainly to photosynthesis in higher plants. All numbers are taken directly from a literature or database source and the corresponding reference is provided. The numerical values, presented in this paper, provide ranges of values, obtained in specific experiments for specific organisms. However, the presented numbers can be useful for understanding the principles of structure and function of photosynthetic machinery and for guidance of future research.
Ngole-Jeme, Veronica M
2016-04-01
Soils enriched with heavy metals from vehicular emission present a significant exposure route of heavy metals to individuals using unpaved roads. This study assessed the extent of Cd, Cr, Co, Cu, Ni, Pb and Zn contamination of soils along unpaved roads in Cameroon, and the health risks presented by incidental ingestion and dermal contact with the soils using metal contamination factor (CF) pollution load index, hazard quotients (HQ) and chronic hazard index (CHI). CF values obtained (0.9-12.2) indicate moderate to high contamination levels. HQ values for Cr, Cd and Pb exceeded the reference doses. Moderate health hazard exists for road users in the areas with intense anthropogenic activities and high average daily traffic (ADT) volume according to CHI values (1-4) obtained. The economy and quality of life in cities with unpaved roads could be threatened by health challenges resulting from long-term exposure to heavy metal derived from high ADT volumes.
Poláček, Roman; Májek, Pavel; Hroboňová, Katarína; Sádecká, Jana
2016-04-01
Fluoxetine is the most prescribed antidepressant chiral drug worldwide. Its enantiomers have a different duration of serotonin inhibition. A novel simple and rapid method for determination of the enantiomeric composition of fluoxetine in pharmaceutical pills is presented. Specifically, emission, excitation, and synchronous fluorescence techniques were employed to obtain the spectral data, which with multivariate calibration methods, namely, principal component regression (PCR) and partial least square (PLS), were investigated. The chiral recognition of fluoxetine enantiomers in the presence of β-cyclodextrin was based on diastereomeric complexes. The results of the multivariate calibration modeling indicated good prediction abilities. The obtained results for tablets were compared with those from chiral HPLC and no significant differences are shown by Fisher's (F) test and Student's t-test. The smallest residuals between reference or nominal values and predicted values were achieved by multivariate calibration of synchronous fluorescence spectral data. This conclusion is supported by calculated values of the figure of merit.
NASA Astrophysics Data System (ADS)
Nakano, Tohru; Shimazaki, Takeshi; Tamura, Osamu
2017-07-01
This study confirms reproducibility of the International Temperature Scale of 1990 (ITS-90) realized by interpolation using the constant-volume gas thermometer (CVGT) of National Metrology Institute of Japan (NMIJ)/AIST with 3He as the working gas from 3 K to 24.5561 K by comparing the newly obtained results and those of earlier reports, indicating that the CVGT has retained its capability after renovation undertaken since strong earthquakes struck Japan. The thermodynamic temperature T is also obtained using the single-isotherm fit to four working gas densities (127 mol\\cdot m^{-3}, 145 mol\\cdot m^{-3}, 171 mol\\cdot m^{-3} and 278 mol\\cdot m^{-3}) down to 1.9 K, using the triple point temperature of Ne as a reference temperature. In this study, only the second virial coefficient is taken into account for the single-isotherm fit. Differences between T and the ITS-90 temperature, T-T_{90}, reported in earlier works down to 3 K were confirmed in this study. At the temperatures below 3 K down to 2.5 K, T-T_{90} is much smaller than the standard combined uncertainty of thermodynamic temperature measurement. However, T- T_{90} seems to increase with decreasing temperature below 2.5 K down to 1.9 K, although still within the standard combined uncertainty of thermodynamic temperature measurement. In this study, T is obtained also from the CVGT with a single gas density of 278 mol\\cdot m^{-3} using the triple-point temperature of Ne as a reference temperature by making correction for the deviation from the ideal gas using theoretical values of the second and third virial coefficients down to 2.6 K, which is the lowest temperature of the theoretical values of the third virial coefficient. T values obtained using this method agree well with those obtained from the single-isotherm fit. We also found that the second virial coefficient obtained by the single-isotherm fit to experimental results agrees well with that obtained by the single-isotherm fit to the theoretically expected behavior of 3He gas with the theoretical second and third virial coefficients at four gas densities used in the present work.
NASA Technical Reports Server (NTRS)
Lorenz-Meyer, W.
1977-01-01
In connection with the question on the applicability of test results obtained from cryogenic wind tunnels to the large-scale model the similarity parameter is referred to. A simple method is given for calculating the similarity parameter. From the numerical values obtained it can be deduced that nitrogen behaves practically like an ideal gas when it is close to the saturation point and in a pressure range up to 4 bar. The influence of this parameter on the pressure distribution of a supercritical profile confirms this finding.
Photographic observations of six comets
NASA Astrophysics Data System (ADS)
de Sanctis, G.; Ferreri, W.; Zappala, V.
Sixty-nine positions of six comets are given as obtained from photographic observations made at the Observatory of Torino from October 1980 to September 1982. Positions are given for Comets Encke, Stephan-Oterma, Meier, Bradfield, Panther, and Austin. Plates were measured with a Zeiss two-coordinate measuring machine. The AGK3 catalog was used to obtain the positions of reference stars and the coordinates of an additional cataloged star near the position of the comet on the plate. The mean values of the differences between the cataloged positions were found to be 0.72 arcsec and 0.52 arcsec in right ascension and declination, respectively.
Flameless atomic-absorption determination of gold in geological materials
Meier, A.L.
1980-01-01
Gold in geologic material is dissolved using a solution of hydrobromic acid and bromine, extracted with methyl isobutyl ketone, and determined using an atomic-absorption spectrophotometer equipped with a graphite furnace atomizer. A comparison of results obtained by this flameless atomic-absorption method on U.S. Geological Survey reference rocks and geochemical samples with reported values and with results obtained by flame atomic-absorption shows that reasonable accuracy is achieved with improved precision. The sensitivity, accuracy, and precision of the method allows acquisition of data on the distribution of gold at or below its crustal abundance. ?? 1980.
25 years of HBM in the Czech Republic.
Černá, Milena; Puklová, Vladimíra; Hanzlíková, Lenka; Sochorová, Lenka; Kubínová, Růžena
2017-03-01
Since 1991 a human biomonitoring network has been established in the Czech Republic as part of the Environmental Health Monitoring System, which was set out by the Government Resolution. During the last quarter-century, important data was obtained to characterize exposure to both children and adult populations to significant toxic substances from the environment, to development trends over time, to establish reference values and compare them with existing health-related values. Moreover, the saturation of population with several essential substances as selenium, zinc, copper or iodine has also been monitored. Development of analytical and statistical methods led to increase the capacity building, improvement of QA/QC in analytical laboratories and interpretation of results. The obtained results are translated to policy actions and are used in health risk assessment processes at local and national levels. Copyright © 2016 Elsevier GmbH. All rights reserved.
Fernández, M D; López, J C; Baeza, E; Céspedes, A; Meca, D E; Bailey, B
2015-08-01
A typical meteorological year (TMY) represents the typical meteorological conditions over many years but still contains the short term fluctuations which are absent from long-term averaged data. Meteorological data were measured at the Experimental Station of Cajamar 'Las Palmerillas' (Cajamar Foundation) in Almeria, Spain, over 19 years at the meteorological station and in a reference greenhouse which is typical of those used in the region. The two sets of measurements were subjected to quality control analysis and then used to create TMY datasets using three different methodologies proposed in the literature. Three TMY datasets were generated for the external conditions and two for the greenhouse. They were assessed by using each as input to seven horticultural models and comparing the model results with those obtained by experiment in practical trials. In addition, the models were used with the meteorological data recorded during the trials. A scoring system was used to identify the best performing TMY in each application and then rank them in overall performance. The best methodology was that of Argiriou for both greenhouse and external conditions. The average relative errors between the seasonal values estimated using the 19-year dataset and those using the Argiriou greenhouse TMY were 2.2 % (reference evapotranspiration), -0.45 % (pepper crop transpiration), 3.4 % (pepper crop nitrogen uptake) and 0.8 % (green bean yield). The values obtained using the Argiriou external TMY were 1.8 % (greenhouse reference evapotranspiration), 0.6 % (external reference evapotranspiration), 4.7 % (greenhouse heat requirement) and 0.9 % (loquat harvest date). Using the models with the 19 individual years in the historical dataset showed that the year to year weather variability gave results which differed from the average values by ± 15 %. By comparison with results from other greenhouses it was shown that the greenhouse TMY is applicable to greenhouses which have a solar radiation transmission of approximately 65 % and rely on manual control of ventilation which constitute the majority in the south-east of Spain and in most Mediterranean greenhouse areas.
NASA Astrophysics Data System (ADS)
Fernández, M. D.; López, J. C.; Baeza, E.; Céspedes, A.; Meca, D. E.; Bailey, B.
2015-08-01
A typical meteorological year (TMY) represents the typical meteorological conditions over many years but still contains the short term fluctuations which are absent from long-term averaged data. Meteorological data were measured at the Experimental Station of Cajamar `Las Palmerillas' (Cajamar Foundation) in Almeria, Spain, over 19 years at the meteorological station and in a reference greenhouse which is typical of those used in the region. The two sets of measurements were subjected to quality control analysis and then used to create TMY datasets using three different methodologies proposed in the literature. Three TMY datasets were generated for the external conditions and two for the greenhouse. They were assessed by using each as input to seven horticultural models and comparing the model results with those obtained by experiment in practical trials. In addition, the models were used with the meteorological data recorded during the trials. A scoring system was used to identify the best performing TMY in each application and then rank them in overall performance. The best methodology was that of Argiriou for both greenhouse and external conditions. The average relative errors between the seasonal values estimated using the 19-year dataset and those using the Argiriou greenhouse TMY were 2.2 % (reference evapotranspiration), -0.45 % (pepper crop transpiration), 3.4 % (pepper crop nitrogen uptake) and 0.8 % (green bean yield). The values obtained using the Argiriou external TMY were 1.8 % (greenhouse reference evapotranspiration), 0.6 % (external reference evapotranspiration), 4.7 % (greenhouse heat requirement) and 0.9 % (loquat harvest date). Using the models with the 19 individual years in the historical dataset showed that the year to year weather variability gave results which differed from the average values by ± 15 %. By comparison with results from other greenhouses it was shown that the greenhouse TMY is applicable to greenhouses which have a solar radiation transmission of approximately 65 % and rely on manual control of ventilation which constitute the majority in the south-east of Spain and in most Mediterranean greenhouse areas.
Brand, Willi A; Rothe, Michael; Sperlich, Peter; Strube, Martin; Wendeberg, Magnus
2016-07-15
The isotopic composition of greenhouse gases helps to constrain global budgets and to study sink and source processes. We present a new system for high-precision stable isotope measurements of carbon, hydrogen and oxygen in atmospheric methane and carbon dioxide. The design is intended for analyzing flask air samples from existing sampling programs without the need for extra sample air for methane analysis. CO2 and CH4 isotopes are measured simultaneously using two isotope ratio mass spectrometers, one for the analysis of δ(13) C and δ(18) O values and the second one for δ(2) H values. The inlet carousel delivers air from 16 sample positions (glass flasks 1-5 L and high-pressure cylinders). Three 10-port valves take aliquots from the sample stream. CH4 from 100-mL air aliquots is preconcentrated in 0.8-mL sample loops using a new cryo-trap system. A precisely calibrated working reference air is used in parallel with the sample according to the Principle of Identical Treatment. It takes about 36 hours for a fully calibrated analysis of a complete carousel including extractions of four working reference and one quality control reference air. Long-term precision values, as obtained from the quality control reference gas since 2012, account for 0.04 ‰ (δ(13) C values of CO2 ), 0.07 ‰ (δ(18) O values of CO2 ), 0.11 ‰ (δ(13) C values of CH4 ) and 1.0 ‰ (δ(2) H values of CH4 ). Within a single day, the system exhibits a typical methane δ(13) C standard deviation (1σ) of 0.06 ‰ for 10 repeated measurements. The system has been in routine operation at the MPI-BGC since 2012. Consistency of the data and compatibility with results from other laboratories at a high precision level are of utmost importance. A high sample throughput and reliability of operation are important achievements of the presented system to cope with the large number of air samples to be analyzed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Tampubolon, Togi; Hutahaean, Juniar; Siregar, Suryani N. J.
2018-03-01
Underwater research often uses geomagnets. It is one of the geophysical methods for measuring magnetic field variations. This research was done to identify how the subsurface rock structure is and determine kinds of rock based on its susceptibility value in Siogung-ogung geothermal area, Pangururan, Samosir District. The tool measurement of total magnetic field called Proton Precission Magnetometer, positioning using Global Position System, and north axis determination using geological compass. Data collection was done randomly with total 51 measuring points obtained. Data analysis started with International geomagnetics Reference Field correction to obtain the total magnetic field anomaly. Then, the data analysis of total magnetic anomaly was done by using surfer program 12. To get a magnetic anomaly cross section used Magdc For Windows program. Magnetic measurement results indicated that the variation of magnetic field strength in each point with the lowest magnetic intensity value of 41785.67 nano tesla. The highest magnetic intensity value is 43140, 33. From the results of qualitative interpretation, the magnetic anomaly value is at -200.92 to 1154.45 whereas the quantitative interpretive results of model show the existence of degradation and andesitic rocks, with the value of susceptibility
McGann, Patrick T.; Tyburski, Erika A.; de Oliveira, Vysolela; Santos, Brigida; Ware, Russell E.; Lam, Wilbur A.
2016-01-01
Severe anemia is an important cause of morbidity and mortality among children in resource-poor settings, but laboratory diagnostics are often limited in these locations. To address this need, we developed a simple, inexpensive, and color-based point-of-care (POC) assay to detect severe anemia. The purpose of this study was to evaluate the accuracy of this novel POC assay to detect moderate and severe anemia in a limited-resource setting. The study was a cross-sectional study conducted on children with sickle cell anemia in Luanda, Angola. The hemoglobin concentrations obtained by the POC assay were compared to reference values measured by a calibrated automated hematology analyzer. A total of 86 samples were analyzed (mean hemoglobin concentration 6.6 g/dL). There was a strong correlation between the hemoglobin concentrations obtained by the POC assay and reference values obtained from an automated hematology analyzer (r=0.88, P<0.0001). The POC assay demonstrated excellent reproducibility (r=0.93, P<0.0001) and the reagents appeared to be durable in a tropical setting (r=0.93, P<0.0001). For the detection of severe anemia that may require blood transfusion (hemoglobin <5 g/dL), the POC assay had sensitivity of 88.9% and specificity of 98.7%. These data demonstrate that an inexpensive (<$0.25 USD) POC assay accurately estimates low hemoglobin concentrations and has the potential to become a transformational diagnostic tool for severe anemia in limited-resource settings. PMID:26317494
NASA Astrophysics Data System (ADS)
Gu, Tingwei; Kong, Deren; Shang, Fei; Chen, Jing
2018-04-01
This paper describes the merits and demerits of different sensors for measuring propellant gas pressure, the applicable range of the frequently used dynamic pressure calibration methods, and the working principle of absolute quasi-static pressure calibration based on the drop-weight device. The main factors affecting the accuracy of pressure calibration are analyzed from two aspects of the force sensor and the piston area. To calculate the effective area of the piston rod and evaluate the uncertainty between the force sensor and the corresponding peak pressure in the absolute quasi-static pressure calibration process, a method for solving these problems based on the least squares principle is proposed. According to the relevant quasi-static pressure calibration experimental data, the least squares fitting model between the peak force and the peak pressure, and the effective area of the piston rod and its measurement uncertainty, are obtained. The fitting model is tested by an additional group of experiments, and the peak pressure obtained by the existing high-precision comparison calibration method is taken as the reference value. The test results show that the peak pressure obtained by the least squares fitting model is closer to the reference value than the one directly calculated by the cross-sectional area of the piston rod. When the peak pressure is higher than 150 MPa, the percentage difference is less than 0.71%, which can meet the requirements of practical application.
Kawaguchi, Migaku; Takatsu, Akiko
2009-08-01
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.
Normative Standards for HRpQCT Parameters in Chinese Men and Women.
Zhu, Tracy Y; Yip, Benjamin Hk; Hung, Vivian Wy; Choy, Carol Wy; Cheng, Ka-Lo; Kwok, Timothy Cy; Cheng, Jack Cy; Qin, Ling
2018-06-12
Assessing bone architecture using high resolution peripheral quantitative computed tomography (HRpQCT) has the potential to improve fracture risk assessment. The Normal Reference Study aimed to establish sex-specific reference centile curves for HRpQCT parameters. This was an age-stratified cross-sectional study and 1,072 ambulatory Chinese men (n = 544) and women (n = 528) aged 20-79yrs, who were free from conditions and medications that could affect bone metabolism and had no history of fragility fracture, were recruited from local communities of Hong Kong. Reference centile curves for each HRpQCT parameter were constructed using Generalized Additive Models for Location, Scale and Shape with age as the only explanatory variable. Patterns of reference centile curves reflected age-related changes of bone density, microarchitecture, and estimated bone strength. In both sexes, loss of cortical bone was only evident in mid-adulthood, particularly in women with a more rapid fashion probably concurrent with the onset of menopause. In contrast, loss of trabecular bone was subtle or gradual or occurred at an earlier age. Expected values of HRpQCT parameters for a defined sex and age, and a defined percentile or z-score were obtained from these curves. T-scores were calculated using the population with the peak values as the reference and reflected age- or menopause-related bone loss in an older individual or the room to reach the peak potential in a younger individual. These reference centile curves produced a standard describing a norm or desirable target that enables value clinical judgements. Percentiles, z-scores and T-scores would be helpful in detecting abnormalities in bone density and microarchitecture arising from various conditions and establishing entry criteria for clinical trials. They also hold the potential to refine the diagnosis of osteoporosis and assessment of fracture risk. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Clinical chemistry reference values for 75-year-old apparently healthy persons.
Huber, Klaus Roland; Mostafaie, Nazanin; Stangl, Gerhard; Worofka, Brigitte; Kittl, Eva; Hofmann, Jörg; Hejtman, Milos; Michael, Rainer; Weissgram, Silvia; Leitha, Thomas; Jungwirth, Susanne; Fischer, Peter; Tragl, Karl-Heinz; Bauer, Kurt
2006-01-01
Clinical chemistry reference values for elderly persons are sparse and mostly intermixed with those for younger subjects. To understand the links between metabolism and aging, it is paramount to differentiate between "normal" physiological processes in apparently healthy elderly subjects and metabolic changes due to long-lasting diseases. The Vienna Transdanube Aging (VITA) study, which began in 2000 and is continuing, will allow us to do just that, because more than 600 male and female volunteers aged exactly 75 years (to exclude any influence of the "aging" factor in this cohort) are participating in this study. Extensive clinical, neurological, biochemical, psychological, genetic, and radiological analyses, with a special emphasis on consumption of medication and abuse of drugs, were performed on each of the probands. The multitude of data and questionnaires obtained made possible an a posteriori approach to select individuals fulfilling criteria for a reference sample group of apparently healthy 75-year-old subjects for our study. Specific analytes were quantified on automated clinical analyzers, while manual methods were used for hormonal analytes. All clinical chemistry analytes were evaluated using in-depth statistical analyses with SPSS for Windows. In all, reference intervals for 45 analytes could be established. These include routine parameters for the assessment of organ functions, as well as hormone concentrations and hematological appraisals. Because all patients were reevaluated after exactly 30 months in the course of this study, we had the opportunity to reassess their health status at the age of 77.5 years. This was very useful for validation of the first round data set. Data of the second round evaluation corroborate the reference limits of the baseline analysis and further confirm our inclusion and exclusion criteria. In summary, we have established a reliable set of reference data for hormonal, hematological, and clinical chemistry analytes for elderly subjects. These values will be very useful for our future attempts to correlate disease states and aging processes with metabolic factors.
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-07-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.
NASA Astrophysics Data System (ADS)
Salem, A. A.; Mossa, H. A.; Barsoum, B. N.
2005-11-01
Rapid, specific and simple methods for determining levofloxacin and rifampicin antibiotic drugs in pharmaceutical and human urine samples were developed. The methods are based on 1H NMR spectroscopy using maleic acid as an internal standard and DMSO-d6 as NMR solvent. Integration of NMR signals at 8.9 and 8.2 ppm were, respectively, used for calculating the concentration of levofloxacin and rifampicin drugs per unit dose. Maleic acid signal at 6.2 ppm was used as the reference signal. Recoveries of (97.0-99.4) ± 0.5 and (98.3-99.7) ± 1.08% were obtained for pure levofloxacin and rifampicin, respectively. Corresponding recoveries of 98.5-100.3 and 96.8-100.0 were, respectively, obtained in pharmaceutical capsules and urine samples. Relative standard deviations (R.S.D.) values ≤2.7 were obtained for analyzed drugs in pure, pharmaceutical and urine samples. Statistical Student's t-test gave t-values ≤2.87 indicating insignificant difference between the real and the experimental values at the 95% confidence level. F-test revealed insignificant difference in precisions between the developed NMR methods and each of fluorimetric and HPLC methods for analyzing levofloxacin and rifampicin.
Method for high-accuracy reflectance measurements in the 2.5-microm region.
Richter, Rudolf; Müller, Andreas
2003-02-20
Reflectance measurement with spectroradiometers in the solar wavelength region (0.4-2.5 microm) are frequently conducted in the laboratory or in the field to characterize surface materials of artificial and natural targets. The spectral surface reflectance is calculated as the ratio of the signals obtained over the target surface and a reference panel, yielding a relative reflectance value. If the reflectance of the reference panel is known, the absolute target reflectance can be computed. This standard measurement technique assumes that the signal at the radiometer is due completely to reflected target and reference radiation. However, for field measurements in the 2.4-2.5-microm region with the Sun as the illumination source, the emitted thermal radiation is not a negligible part of the signal even at ambient temperatures, because the atmospheric transmittance, and thus the solar illumination level, is small in the atmospheric absorption regions. A new method is proposed that calculates reflectance values in the 2.4-2.5-microm region while it accounts for the reference panel reflectance and the emitted radiation. This technique needs instruments with noise-equivalent radiances of 2 orders of magnitude below currently commercially available instruments and requires measurement of the surface temperatures of target and reference. If the reference panel reflectance and temperature effects are neglected, the standard method yields reflectance errors up to 0.08 and 0.15 units for 7- and 2-nm bandwidth instruments, respectively. For the new method the corresponding errors can be reduced to approximately 0.01 units for the surface temperature range of 20-35 degrees C.
Hansson, H; Lagerkvist, C J; Azar, G
2018-01-24
This study explored how farmers' motivation in terms of use values and/or non-use values to work with farm animal welfare are associated with the economic outcome for the farm. Use values in farm animal welfare refer to economic value derived from productivity and profitability considerations. Non-use values in farm animal welfare refer to economic value derived from good animal welfare, irrespective of the use the farmer derives from the animal, currently or in the future. The analysis was based on detailed information about the income statements of a sample of Swedish dairy farmers, obtained from the Swedish Farm Economic Survey, complemented with survey information about their perceived use and non-use values in farm animal welfare. The findings suggest that farm economic outcome is significantly associated with motivation in terms of use values, but not so much with motivation in terms of non-use values. This is interesting from a policy point of view, because it indicates that farmers with different approaches to farm animal welfare may experience different economic outcomes for their farms. Findings can, for instance, be used to strengthen farmers' engagement in various private quality assurance standards, which generally focus on values of non-use type, by pointing to that realisation of such values will not impair the economic outcome of the farms. Moreover, findings also suggest that farmers' economic incentives for engagement in such standards may need to be further strengthened in order to become more attractive, as findings point to that a focus on non-use values generally is not associated with more favourable economic outcomes.
Can multi-subpopulation reference sets improve the genomic predictive ability for pigs?
Fangmann, A; Bergfelder-Drüing, S; Tholen, E; Simianer, H; Erbe, M
2015-12-01
In most countries and for most livestock species, genomic evaluations are obtained from within-breed analyses. To achieve reliable breeding values, however, a sufficient reference sample size is essential. To increase this size, the use of multibreed reference populations for small populations is considered a suitable option in other species. Over decades, the separate breeding work of different pig breeding organizations in Germany has led to stratified subpopulations in the breed German Large White. Due to this fact and the limited number of Large White animals available in each organization, there was a pressing need for ascertaining if multi-subpopulation genomic prediction is superior compared with within-subpopulation prediction in pigs. Direct genomic breeding values were estimated with genomic BLUP for the trait "number of piglets born alive" using genotype data (Illumina Porcine 60K SNP BeadChip) from 2,053 German Large White animals from five different commercial pig breeding companies. To assess the prediction accuracy of within- and multi-subpopulation reference sets, a random 5-fold cross-validation with 20 replications was performed. The five subpopulations considered were only slightly differentiated from each other. However, the prediction accuracy of the multi-subpopulations approach was not better than that of the within-subpopulation evaluation, for which the predictive ability was already high. Reference sets composed of closely related multi-subpopulation sets performed better than sets of distantly related subpopulations but not better than the within-subpopulation approach. Despite the low differentiation of the five subpopulations, the genetic connectedness between these different subpopulations seems to be too small to improve the prediction accuracy by applying multi-subpopulation reference sets. Consequently, resources should be used for enlarging the reference population within subpopulation, for example, by adding genotyped females.
Simplified estimation of age-specific reference intervals for skewed data.
Wright, E M; Royston, P
1997-12-30
Age-specific reference intervals are commonly used in medical screening and clinical practice, where interest lies in the detection of extreme values. Many different statistical approaches have been published on this topic. The advantages of a parametric method are that they necessarily produce smooth centile curves, the entire density is estimated and an explicit formula is available for the centiles. The method proposed here is a simplified version of a recent approach proposed by Royston and Wright. Basic transformations of the data and multiple regression techniques are combined to model the mean, standard deviation and skewness. Using these simple tools, which are implemented in almost all statistical computer packages, age-specific reference intervals may be obtained. The scope of the method is illustrated by fitting models to several real data sets and assessing each model using goodness-of-fit techniques.
Ridefelt, Peter; Aldrimer, Mattias; Rödöö, Per-Olof; Niklasson, Frank; Jansson, Leif; Gustafsson, Jan; Hellberg, Dan
2012-02-29
Reference intervals are crucial decision-making tools aiding clinicians in differentiating between healthy and diseased populations. However, for children such values often are lacking or incomplete. Blood samples were obtained from 692 healthy children, aged 6 months to 18 years, recruited in daycare centers and schools. Twelve common general clinical chemistry analytes were measured on the Abbott Architect ci8200 platform; sodium, potassium, chloride, calcium, albumin-adjusted calcium, phosphate, magnesium, creatinine (Jaffe and enzymatic), cystatin C, urea and uric acid. Age- and gender specific pediatric reference intervals were defined by calculating the 2.5th and 97.5th percentiles. The data generated is primarily applicable to a Caucasian population when using the Abbott Architect platform, but could be used by any laboratory if validated for the local patient population.
Reference range of blood biomarkers for oxidative stress in Thoroughbred racehorses (2–5 years old)
KUSANO, Kanichi; YAMAZAKI, Masahiko; KIUCHI, Masataka; KANEKO, Kouki; KOYAMA, Katsuhiro
2016-01-01
ABSTRACT The oxidant and antioxidant equilibrium is known to play an important role in equine medicine and equine exercise physiology. There are abundant findings in this field; however, not many studies have been conducted for reference ranges of oxidative stress biomarkers in horses. This study was conducted to determine the reference values of reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP) using blood samples from 372 (191 males, 181 females) Thoroughbred racehorse aged 2 to 5 (3.43 ± 1.10 (mean ± SD)) years old. There were obvious gender differences in oxidative biomarkers, and growth/age-related changes were observed especially in females. Gender and age must be considered when interpreting obtained oxidative stress biomarkers for diagnosis of disease or fitness alterations in Thoroughbred racehorses. PMID:27703408
Yao, Dezhong; Wang, Li; Arendt-Nielsen, Lars; Chen, Andrew C N
2007-11-01
Reference is a very virtual issue in EEG and ERP. Understanding the difference of various references will make the applications more confident. In this work, somatosensory evoked potential (SEP) with stimulation on the right hand was studied. The SEP spatio-temporal analysis was conducted comparatively on six references, left mastoid (contralateral mastoid reference, CM), right mastoid (ipsilateral mastoid reference, IM), linked mastoids (LM), average reference (AR), vertex reference (Cz) and the infinity reference (IR) newly proposed in 2001. Among the six, CM is the one used in actual recordings, and the other five are obtained by off-line re-referencing. The comparison is conducted on four selected components (P30 ms, P40 ms, N90 ms and P230 ms) in both temporal and spatial aspects. The results show that references may have a distinct influence on the amplitudes of the scalp potentials, with relative error at some electrodes larger than 500%, and for some electrodes it may even change the polarity. Pair-wise multiple comparison (Tukey test) shows that the differences of peak values among various references are very significant (P<0.001) between Cz and IR\\CM\\IM\\LM, and significant (P<0.01) between Cz and AR for component N90 ms; very significant (P<0.001) between Cz and IR\\CM\\IM\\LM\\AR, significant between IMLM and AR (P<0.01), CM and AR (P<0.05) for component P230 ms. The amplitude value order is CM/IM> or =LM>IR>AR>Cz. The two-ways (the six references vs. the four Peaks) repeated measures ANOVA test shows the effect of different references depends on various components; there is a statistically significant interaction between reference and the peak (P=<0.001). While for the spatial map of the potential amplitude, references will not affect the amplitude map shape if the color-bar is selected automatically, but if a fixed color-bar is chosen for data of various references, they may show some differences. These results mean a common reference is important for producing a comparable result between labs. As IR is theoretically a constant reference, we recommend it as the common choice in the future.
Lejarraga, Horacio; del Pino, Mariana; Fano, Virginia; Caino, Silvia; Cole, Timothy J
2009-04-01
Argentine growth references have been widely used by paediatricians in the country for the last 20 years. Two main difficulties were detected during this period: the lack of data on breast-fed children in the first months of age, and problems in the calculation of "z" scores. On these basis, local data on weight and height during the first two years of life were replaced by data from the longitudinal international study recently carried out by WHO. L, M and S values were obtained from the original percentile data for ages 2 to maturity, and smoothed with cubic splines. Selected percentiles for weight and height from birth to maturity were then re-calculated using LMS values. Charts were designed in two formats: birth to maturity and birth to 6.0 years. Now, users can calculate "z" scores automatically at the new site provided by the Department of Growth and Development, Hospital Garrahan, which enables the use of the LMS growth programme. We have also incorporated into the new charts, percentiles of the age of attaining menarche and Tanner s stage II of breast, genitalia and pubic hair for Argentine children. We think the new references represent an improvement in the assessment of growth in our country.
[European community guidelines and standards in indoor air quality: what proposals for Italy].
Settimo, Gaetano; D'Alessandro, Daniela
2014-01-01
Indoor air quality is an issue on which to focus because of the increasing number of exposed population and in view of the strong public feeling on this issue. This paper reports the rules of EU and several European countries about indoor air quality, focusing on the initiatives performed in Italy to respond to WHO recommendations. Several EU countries have introduced in their legislation rules relating to indoor air quality. At the moment, in Italy, a reference rule has not been issued. For this reason, up to date main informations concerning some guidelines or reference values in indoor air, to be used for a first comparison, are those obtained by the scientific literature, or by the guidelines issued by other European countries or, for analogy, by other standard values such as limit or reference values regarding outdoor air. Even the EU, while reaffirming the priority of energy efficiency measures, recommends healthier indoor environments and the development of a specific European strategy on the issue of indoor air quality. The National Study Group on indoor pollution of the Italian National Health Institute (ISS), is working for the development of shared technical and scientific documents, in order to provide greater uniformity of actions at national level, waiting for a legal framework for indoor air quality, in the light of the indication already produced by the WHO.
NASA Astrophysics Data System (ADS)
Janssen, Christof; Elandaloussi, Hadj; Gröbner, Julian
2018-03-01
The room temperature (294.09 K) absorption cross section of ozone at the 325 nm HeCd wavelength has been determined under careful consideration of possible biases. At the vacuum wavelength of 325.126 nm, thus in a region used by a variety of ozone remote sensing techniques, an absorption cross-section value of σ = 16.470×10-21 cm2 was measured. The measurement provides the currently most accurate direct photometric absorption value of ozone in the UV with an expanded (coverage factor k = 2) standard uncertainty u(σ) = 31×10-24 cm2, corresponding to a relative level of 2 ‰. The measurements are most compatible with a relative temperature coefficient cT = σ-1 ∂ Tσ = 0.0031 K-1 at 294 K. The cross section and its uncertainty value were obtained using generalised linear regression with correlated uncertainties. It will serve as a reference for ozone absorption spectra required for the long-term remote sensing of atmospheric ozone in the Huggins bands. The comparison with commonly used absorption cross-section data sets for remote sensing reveals a possible bias of about 2 %. This could partly explain a 4 % discrepancy between UV and IR remote sensing data and indicates that further studies will be required to reach the accuracy goal of 1 % in atmospheric reference spectra.
Wenric, Stephane; Sticca, Tiberio; Caberg, Jean-Hubert; Josse, Claire; Fasquelle, Corinne; Herens, Christian; Jamar, Mauricette; Max, Stéphanie; Gothot, André; Caers, Jo; Bours, Vincent
2017-01-01
An increasing number of bioinformatic tools designed to detect CNVs (copy number variants) in tumor samples based on paired exome data where a matched healthy tissue constitutes the reference have been published in the recent years. The idea of using a pool of unrelated healthy DNA as reference has previously been formulated but not thoroughly validated. As of today, the gold standard for CNV calling is still aCGH but there is an increasing interest in detecting CNVs by exome sequencing. We propose to design a metric allowing the comparison of two CNV profiles, independently of the technique used and assessed the validity of using a pool of unrelated healthy DNA instead of a matched healthy tissue as reference in exome-based CNV detection. We compared the CNV profiles obtained with three different approaches (aCGH, exome sequencing with a matched healthy tissue as reference, exome sequencing with a pool of eight unrelated healthy tissue as reference) on three multiple myeloma samples. We show that the usual analyses performed to compare CNV profiles (deletion/amplification ratios and CNV size distribution) lack in precision when confronted with low LRR values, as they only consider the binary status of each CNV. We show that the metric-based distance constitutes a more accurate comparison of two CNV profiles. Based on these analyses, we conclude that a reliable picture of CNV alterations in multiple myeloma samples can be obtained from whole-exome sequencing in the absence of a matched healthy sample. © 2016 WILEY PERIODICALS, INC.
Revised reference values for selenium intake.
Kipp, A P; Strohm, D; Brigelius-Flohé, R; Schomburg, L; Bechthold, A; Leschik-Bonnet, E; Heseker, H
2015-10-01
The German, Austrian and Swiss nutrition societies are the joint editors of the 'reference values for nutrient intake'. They have revised the reference values for the intake of selenium and published them in February 2015. The saturation of selenoprotein P (SePP) in plasma is used as a criterion for the derivation of reference values for selenium intake in adults. For persons from selenium-deficient regions (China) SePP saturation was achieved with a daily intake of 49μg of selenium. When using the reference body weights the D-A-CH reference values are based upon, the resulting estimated value for selenium intake is 70μg/day for men and 60μg/day for women. The estimated value for selenium intake for children and adolescents is extrapolated using the estimated value for adults in relation to body weight. For infants aged 0 to under 4 months the estimated value of 10μg/day was derived from the basis of selenium intake via breast milk. For infants aged 4 to under 12 months this estimated value was used and taking into account the differences regarding body weight an estimated value of 15μg/day was derived. For lactating women compared to non-lactating women a higher reference value of 75μg/day is indicated due to the release of selenium with breast milk. The additional selenium requirement for pregnant women is negligible, so that no increased reference value is indicated. Copyright © 2015 The Authors. Published by Elsevier GmbH.. All rights reserved.
Evaluation of Cetane Improver Additive in Alternative Jet Fuel Blends
2016-07-01
diesel engines are sensitive to cetane values of fuel. Some fuels originating from nonpetroleum sources contain low cetane numbers that have trouble...Improver Additive, Diesel Fuel, JP-8, Kerosene, Aviation Fuel, Alternative Fuel 16. SECURITY CLASSIFICATION OF: a. REPORT ,,b. ABSTRACT r· THIS...performance of a diesel fuel oil obtained by comparing it to reference fuels in a standardized engine test (1). The cetane number has an inverse
Geist, Barbara K; Baltzer, Pascal; Fueger, Barbara; Hamboeck, Martina; Nakuz, Thomas; Papp, Laszlo; Rasul, Sazan; Sundar, Lalith Kumar Shiyam; Hacker, Marcus; Staudenherz, Anton
2018-05-09
A method was developed to assess the kidney parameters glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) from 2-deoxy-2-[ 18 F]fluoro-D-glucose (FDG) concentration behavior in kidneys, measured with positron emission tomography (PET) scans. Twenty-four healthy adult subjects prospectively underwent dynamic simultaneous PET/magnetic resonance imaging (MRI) examination. Time activity curves (TACs) were obtained from the dynamic PET series, with the guidance of MR information. Patlak analysis was performed to determine the GFR, and based on integrals, ERPF was calculated. Results were compared to intra-individually obtained reference values determined from venous blood samples. Total kidney GFR and ERPF as estimated by dynamic PET/MRI were highly correlated to their reference values (r = 0.88/p < 0.0001 and r = 0.82/p < 0.0001, respectively) with no significant difference between their means. The study is a proof of concept that GFR and ERPF can be assessed with dynamic FDG PET/MRI scans in healthy kidneys. This has advantages for patients getting a routine scan, where additional examinations for kidney function estimation could be avoided. Further studies are required for transferring this PET/MRI method to PET/CT applications.
NMR absolute shielding scale and nuclear magnetic dipole moment of (207)Pb.
Adrjan, Bożena; Makulski, Włodzimierz; Jackowski, Karol; Demissie, Taye B; Ruud, Kenneth; Antušek, Andrej; Jaszuński, Michał
2016-06-28
An absolute shielding scale is proposed for (207)Pb nuclear magnetic resonance (NMR) spectroscopy. It is based on ab initio calculations performed on an isolated tetramethyllead Pb(CH3)4 molecule and the assignment of the experimental resonance frequency from the gas-phase NMR spectra of Pb(CH3)4, extrapolated to zero density of the buffer gas to obtain the result for an isolated molecule. The computed (207)Pb shielding constant is 10 790 ppm for the isolated molecule, leading to a shielding of 10799.7 ppm for liquid Pb(CH3)4 which is the accepted reference standard for (207)Pb NMR spectra. The new experimental and theoretical data are used to determine μ((207)Pb), the nuclear magnetic dipole moment of (207)Pb, by applying the standard relationship between NMR frequencies, shielding constants and nuclear moments of two nuclei in the same external magnetic field. Using the gas-phase (207)Pb and (reference) proton results and the theoretical value of the Pb shielding in Pb(CH3)4, we find μ((207)Pb) = 0.59064 μN. The analysis of new experimental and theoretical data obtained for the Pb(2+) ion in water solutions provides similar values of μ((207)Pb), in the range of 0.59000-0.59131 μN.
Miller, Robert; Stalder, Tobias; Jarczok, Marc; Almeida, David M; Badrick, Ellena; Bartels, Meike; Boomsma, Dorret I; Coe, Christopher L; Dekker, Marieke C J; Donzella, Bonny; Fischer, Joachim E; Gunnar, Megan R; Kumari, Meena; Lederbogen, Florian; Power, Christine; Ryff, Carol D; Subramanian, S V; Tiemeier, Henning; Watamura, Sarah E; Kirschbaum, Clemens
2016-11-01
Diurnal salivary cortisol profiles are valuable indicators of adrenocortical functioning in epidemiological research and clinical practice. However, normative reference values derived from a large number of participants and across a wide age range are still missing. To fill this gap, data were compiled from 15 independently conducted field studies with a total of 104,623 salivary cortisol samples obtained from 18,698 unselected individuals (mean age: 48.3 years, age range: 0.5-98.5 years, 39% females). Besides providing a descriptive analysis of the complete dataset, we also performed mixed-effects growth curve modeling of diurnal salivary cortisol (i.e., 1-16h after awakening). Cortisol decreased significantly across the day and was influenced by both, age and sex. Intriguingly, we also found a pronounced impact of sampling season with elevated diurnal cortisol in spring and decreased levels in autumn. However, the majority of variance was accounted for by between-participant and between-study variance components. Based on these analyses, reference ranges (LC/MS-MS calibrated) for cortisol concentrations in saliva were derived for different times across the day, with more specific reference ranges generated for males and females in different age categories. This integrative summary provides important reference values on salivary cortisol to aid basic scientists and clinicians in interpreting deviations from the normal diurnal cycle. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Penis growth and development in children and adolescents: a study based on GAMLSS].
Yi, Qing-Jie; Zeng, Yan; Zeng, Qing; Wang, Yi-Nan; Xiong, Feng
2017-08-01
To investigate penis development in children and adolescents aged 0-16 years, and to plot the percentile curve for penis development in different age groups. A total of 3 024 normal male neonates, children, and adolescents aged 0-16 years in Chongqing, China were selected by simple random sampling and stratified cluster sampling. The length and diameter of the penis were measured for all subjects. A descriptive statistical analysis was used to investigate the data characteristics of the penis, and the GAMLSS fitting model was used to plot the percentile curves of P 3 , P 10 , P 25 , P 50 , P 75 , P 90 , and P97 and obtain percentile reference values. The length and diameter of the penis grew rapidly before the age of 1 year, grew relatively slowly from 1 to 11 years old, and entered a rapid growth period from 11 years old. The length of the penis was positively correlated with its diameter (r=0.961, P<0.01). The percentile reference values of penis length and diameter were obtained and the percentile curve was plotted. The growth and development of penis length is consistent with that of penis diameter in male children and adolescents in Chongqing, and 0-1 year and 11-16 years are rapid growth periods of penis length and diameter. The percentile curve of penis length and diameter in children and adolescents aged 0-16 years in Chongqing which has been established will provide a reference for further studies on sexual development in children and adolescents.
NASA Astrophysics Data System (ADS)
Rohyami, Yuli; Anjani, Rafika Debby; Purwanti, Napthalina Putri
2017-03-01
Virgin coconut oil is an excellent product which has result of oil processing business opportunities in the international market. Standardization of virgin coconut oil necessary to satisfy the requirements industry needs. This research is expected as procedure preparation of reference materials. Preparation of virgin coconut oil by Sacharomycescerevisiaeenzyme. Based on the results of this study concluded that the ratio of Saccharomyces cerevisiae can affect the yield of virgin coconut oil produced. The preparation of virgin coconut oil enzymatically using a variety of mass ratio of 0.001 to 0.006% is obtained yield average of 12.40%. The optimum separation of virgin coconut oil on the use of enzymes with a mass ratio of 0.002%. The average water content at a ratio of 0.002% is 0.04 % with a value of uncertainty is 0.005%. The average iodine number in virgin coconut oil produced is 2.4403 ± 0,1974 grams of iodine per 100 grams of oil and optimum iodine number is obtained from the manufacturing process virgin coconut oil with a ratio of 0.006% Saccharomyces cerevisiae. Sacharomycescerevisiae with a ratio of 0.002% results virgin coconut oil with acid number 0.3068 ± 0.1098%. The peroxide value of virgin coconut oil between 0.0108 ± 0.009 to 0.0114 ± 0015milli-equivalent per kilograms. Organoleptic test results and test chemical parameters can be used as the test data that can be developed in prototype preparation of candidate in-house reference material in the testing standards of quality virgin coconut oil.
NASA Astrophysics Data System (ADS)
Ding, T.; Valkiers, S.; Kipphardt, H.; De Bièvre, P.; Taylor, P. D. P.; Gonfiantini, R.; Krouse, R.
2001-08-01
Calibrated values have been obtained for sulfur isotope abundance ratios of sulfur isotope reference materials distributed by the IAEA (Vienna). For the calibration of the measurements, a set of synthetic isotope mixtures were prepared gravimetrically from high purity Ag2S materials enriched in32S, 33S, and 34S. All materials were converted into SF6 gas and subsequently, their sulfur isotope ratios were measured on the SF5+ species using a special gas source mass spectrometer equipped with a molecular flow inlet system (IRMM's Avogadro II amount comparator). Values for the 32S/34S abundance ratios are 22.650 4(20), 22.142 4(20), and 23.393 3(17) for IAEA-S-1, IAEA-S-2, and IAEA-S-3, respectively. The calculated 32S/34S abundance ratio for V-CDT is 22.643 6(20), which is very close to the calibrated ratio obtained by Ding et al. (1999). In this way, the zero point of the VCDT scale is anchored firmly to the international system of units SI. The 32S/33S abundance ratios are 126.942(47), 125.473(55), 129.072(32), and 126.948(47) for IAEA-S-1, IAEA-S-2, IAEA-S-3, and V-CDT, respectively. In this way, the linearity of the V-CDT scale is improved over this range. The values of the sulfur molar mass for IAEA-S-1 and V-CDT were calculated to be 32.063 877(56) and 32.063 911(56), respectively, the values with the smallest combined uncertainty ever reported for the sulfur molar masses (atomic weights).
An AERONET-Based Aerosol Classification Using the Mahalanobis Distance
NASA Technical Reports Server (NTRS)
Hamill, Patrick; Giordano, Marco; Ward, Carolyne; Giles, David; Holben, Brent
2016-01-01
We present an aerosol classification based on AERONET aerosol data from 1993 to 2012. We used the AERONET Level 2.0 almucantar aerosol retrieval products to define several reference aerosol clusters which are characteristic of the following general aerosol types: Urban-Industrial, Biomass Burning, Mixed Aerosol, Dust, and Maritime. The classification of a particular aerosol observation as one of these aerosol types is determined by its five-dimensional Mahalanobis distance to each reference cluster. We have calculated the fractional aerosol type distribution at 190 AERONET sites, as well as the monthly variation in aerosol type at those locations. The results are presented on a global map and individually in the supplementary material. Our aerosol typing is based on recognizing that different geographic regions exhibit characteristic aerosol types. To generate reference clusters we only keep data points that lie within a Mahalanobis distance of 2 from the centroid. Our aerosol characterization is based on the AERONET retrieved quantities, therefore it does not include low optical depth values. The analysis is based on point sources (the AERONET sites) rather than globally distributed values. The classifications obtained will be useful in interpreting aerosol retrievals from satellite borne instruments.
Imboden, Mary T; Swartz, Ann M; Finch, Holmes W; Harber, Matthew P; Kaminsky, Leonard A
2017-01-01
To develop reference values by age and sex for LM measures using GE-Healthcare DXA systems. A de-identified sample was obtained from Ball State University's Clinical Exercise Physiology Laboratory and University of Wisconsin-Milwaukee's Physical Activity & Health Research Laboratory. DXA scans of 2,076 women and 1,251 men were completed using a GE Lunar Prodigy or iDXA. Percentiles (%ile) were calculated for all variables of interest (LM, LMI, %LM, and ALMI) and a factorial ANOVA was used to assess differences for each variable between 10-year age groups and sex, as well as the interaction between age and sex. Men had higher mean total LM, %LM, LMI, and ALMI than women (p<0.01), across all age groups. All LM variables decreased significantly over the 5 decades in men, however in women only total LM, %LM, and ALMI decreased from the youngest to oldest age groups (p<0.01). These reference values provide for a more accurate interpretation of GE-Healthcare DXA-derived LM measurements offering clinicians and researchers with an initial resource to aid in the early detection and assessment of LM deficits.
Hematological reference values of healthy Malaysian population.
Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N
2009-10-01
Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.
Dagnino, Alessandro; Sforzini, Susanna; Dondero, Francesco; Fenoglio, Stefano; Bona, Elisa; Jensen, John; Viarengo, Aldo
2008-07-01
A new Expert Decision Support System (EDSS) that can integrate Triad data for assessing environmental risk and biological vulnerability at contaminated sites has been developed. Starting with ecosystem relevance, the EDSS assigns different weights to the results obtained from Triad disciplines. The following parameters have been employed: 1) chemical soil analyses (revealing the presence of potentially dangerous substances), 2) ecotoxicological bioassays (utilizing classical endpoints such as survival and reproduction rates), 3) biomarkers (showing sublethal pollutant effects), and 4) ecological parameters (assessing changes in community structure and functions). For each Triad discipline, the EDSS compares the data obtained at the studied field sites with reference values and calculates different 0-1 indexes (e.g., Chemical Risk Index, Ecotoxicological Risk Index, and Ecological Risk Index). The EDSS output consists of 3 indexes: 1) Environmental Risk index (EnvRI), quantifying the levels of biological damage at population-community level, 2) Biological Vulnerability Index (BVI), assessing the potential threats to biological equilibriums, and 3) Genotoxicity Index (GTI), screening genotoxicity effects. The EDSS has been applied in the integration of a battery of Triad data obtained during the European Union-funded Life Intervention in the Fraschetta Area (LINFA) project, which has been carried out in order to estimate the potential risk from soils of a highly anthropized area (Alessandria, Italy) mainly impacted by deposition of atmospheric pollutants. Results obtained during 4 seasonal sampling campaigns (2004-2005) show maximum values of EnvRI in sites A and B (characterized by industrial releases) and lower levels in site D (affected by vehicular traffic emissions). All 3 potentially polluted sites have shown high levels of BVI and GTI, suggesting a general change from reference conditions (site C).
Reference values for pulmonary diffusing capacity for adult native Finns.
Kainu, Annette; Toikka, Jyri; Vanninen, Esko; Timonen, Kirsi L
2017-04-01
Measurement standards for pulmonary diffusing capacity were updated in 2005 by the ATS/ERS Task Force. However, in Finland reference values published in 1982 by Viljanen et al. have been used to date. The main aim of this study was to produce updated reference models for single-breath diffusing capacity for carbon monoxide for Finnish adults. Single-breath diffusing capacity for carbon monoxide was measured in 631 healthy non-smoking volunteers (41.5% male). Reference values for diffusing capacity (DLCO), alveolar volume (VA), diffusing capacity per unit of lung volume (DLCO/VA), and lung volumes were calculated using a linear regression model. Previously used Finnish reference values were found to produce too low predicted values, with mean predicted DLCO 111.0 and 104.4%, and DLCO/VA of 103.5 and 102.7% in males and females, respectively. With the European Coalition for Steel and Coal (ECSC) reference values there was a significant sex difference in DLCO/VA with mean predicted 105.4% in males and 92.8% in females (p < .001). New reference values for DLCO, DLCO/VA, VA, vital capacity (VC), inspiratory vital capacity (IVC), and inspiratory capacity (IC) are suggested for clinical use to replace technically outdated reference values for clinical applications.
Srivastava, Abneesh; Michael Verkouteren, R
2018-07-01
Isotope ratio measurements have been conducted on a series of isotopically distinct pure CO 2 gas samples using the technique of dual-inlet isotope ratio mass spectrometry (DI-IRMS). The influence of instrumental parameters, data normalization schemes on the metrological traceability and uncertainty of the sample isotope composition have been characterized. Traceability to the Vienna PeeDee Belemnite(VPDB)-CO 2 scale was realized using the pure CO 2 isotope reference materials(IRMs) 8562, 8563, and 8564. The uncertainty analyses include contributions associated with the values of iRMs and the repeatability and reproducibility of our measurements. Our DI-IRMS measurement system is demonstrated to have high long-term stability, approaching a precision of 0.001 parts-per-thousand for the 45/44 and 46/44 ion signal ratios. The single- and two-point normalization bias for the iRMs were found to be within their published standard uncertainty values. The values of 13 C/ 12 C and 18 O/ 16 O isotope ratios are expressed relative to VPDB-CO 2 using the [Formula: see text] and [Formula: see text] notation, respectively, in parts-per-thousand (‰ or per mil). For the samples, value assignments between (-25 to +2) ‰ and (-33 to -1) ‰ with nominal combined standard uncertainties of (0.05, 0.3) ‰ for [Formula: see text] and [Formula: see text], respectively were obtained. These samples are used as laboratory reference to provide anchor points for value assignment of isotope ratios (with VPDB traceability) to pure CO 2 samples. Additionally, they serve as potential parent isotopic source material required for the development of gravimetric based iRMs of CO 2 in CO 2 -free dry air in high pressure gas cylinder packages at desired abundance levels and isotopic composition values. Graphical abstract CO 2 gas isotope ratio metrology.
NASA Astrophysics Data System (ADS)
Rodrigo, F. S.; Gómez-Navarro, J. J.; Montávez Gómez, J. P.
2012-01-01
In this work, a reconstruction of climatic conditions in Andalusia (southern Iberian Peninsula) during the period 1701-1850, as well as an evaluation of its associated uncertainties, is presented. This period is interesting because it is characterized by a minimum in solar irradiance (Dalton Minimum, around 1800), as well as intense volcanic activity (for instance, the eruption of Tambora in 1815), at a time when any increase in atmospheric CO2 concentrations was of minor importance. The reconstruction is based on the analysis of a wide variety of documentary data. The reconstruction methodology is based on counting the number of extreme events in the past, and inferring mean value and standard deviation using the assumption of normal distribution for the seasonal means of climate variables. This reconstruction methodology is tested within the pseudoreality of a high-resolution paleoclimate simulation performed with the regional climate model MM5 coupled to the global model ECHO-G. The results show that the reconstructions are influenced by the reference period chosen and the threshold values used to define extreme values. This creates uncertainties which are assessed within the context of climate simulation. An ensemble of reconstructions was obtained using two different reference periods (1885-1915 and 1960-1990) and two pairs of percentiles as threshold values (10-90 and 25-75). The results correspond to winter temperature, and winter, spring and autumn rainfall, and they are compared with simulations of the climate model for the considered period. The mean value of winter temperature for the period 1781-1850 was 10.6 ± 0.1 °C (11.0 °C for the reference period 1960-1990). The mean value of winter rainfall for the period 1701-1850 was 267 ± 18 mm (224 mm for 1960-1990). The mean values of spring and autumn rainfall were 164 ± 11 and 194 ± 16 mm (129 and 162 mm for 1960-1990, respectively). Comparison of the distribution functions corresponding to 1790-1820 and 1960-1990 indicates that during the Dalton Minimum the frequency of dry and warm (wet and cold) winters was lower (higher) than during the reference period: temperatures were up to 0.5 °C lower than the 1960-1990 value, and rainfall was 4% higher.
NASA Astrophysics Data System (ADS)
Landsberger, S.; Peshev, S.; Becker, D. A.
1994-12-01
Silicon determination in sixteen botanical and biological standard reference materials is described using the 29Si(n, p) 29Al reaction through instrumental epithermal neutron activation analysis and Compton suppression gamma-ray spectroscopy. By simultaneous utilization of both cadmium and boron epithermal filters along with anticoincidence gamma-counting, detection limits as low as 12 ppm were obtained for certain matrices, much lower than previously reported values for this type of analysis. The method is applicable to many botanical and biological matrices and is attractive with its interference free, purely instrumental nature, compared with methods using the 28Si(n, p) 28Al reaction or chemical separation techniques.
Improving draft genome contiguity with reference-derived in silico mate-pair libraries.
Grau, José Horacio; Hackl, Thomas; Koepfli, Klaus-Peter; Hofreiter, Michael
2018-05-01
Contiguous genome assemblies are a highly valued biological resource because of the higher number of completely annotated genes and genomic elements that are usable compared to fragmented draft genomes. Nonetheless, contiguity is difficult to obtain if only low coverage data and/or only distantly related reference genome assemblies are available. In order to improve genome contiguity, we have developed Cross-Species Scaffolding-a new pipeline that imports long-range distance information directly into the de novo assembly process by constructing mate-pair libraries in silico. We show how genome assembly metrics and gene prediction dramatically improve with our pipeline by assembling two primate genomes solely based on ∼30x coverage of shotgun sequencing data.
2002-01-01
This report presents detailed information on age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. These reference values provide needed input to prospective dosimetry calculations for radiation protection purposes for both workers and members of the general public. The purpose of this report is to consolidate and unify in one publication, important new information on reference anatomical and physiological values that has become available since Publication 23 was published by the ICRP in 1975. There are two aspects of this work. The first is to revise and extend the information in Publication 23 as appropriate. The second is to provide additional information on individual variation among grossly normal individuals resulting from differences in age, gender, race, or other factors. This publication collects, unifies, and expands the updated ICRP reference values for the purpose of providing a comprehensive and consistent set of age- and gender-specific reference values for anatomical and physiological features of the human body pertinent to radiation dosimetry. The reference values given in this report are based on: (a) anatomical and physiological information not published before by the ICRP; (b) recent ICRP publications containing reference value information; and (c) information in Publication 23 that is still considered valid and appropriate for radiation protection purposes. Moving from the past emphasis on 'Reference Man', the new report presents a series of reference values for both male and female subjects of six different ages: newborn, 1 year, 5 years, 10 years, 15 years, and adult. In selecting reference values, the Commission has used data on Western Europeans and North Americans because these populations have been well studied with respect to antomy, body composition, and physiology. When appropriate, comparisons are made between the chosen reference values and data from several Asian populations. The first section of the report provides summary tables of all the anatomical and physiological parameters given as reference values in this publication. These results give a comprehensive view of reference values for an individual as influenced by age and gender. The second section describes characteristics of dosimetric importance for the embryo and fetus. Information is provided on the development of the total body and the timing of appearance and development of the various organ systems. Reference values are provided on the mass of the total body and selected organs and tissues, as well as a number of physiological parameters. The third section deals with reference values of important anatomical and physiological characteristics of reference individuals from birth to adulthood. This section begins with details on the growth and composition of the total body in males and females. It then describes and quantifies anatomical and physiological characteristics of various organ systems and changes in these characteristics during growth, maturity, and pregnancy. Reference values are specified for characteristics of dosimetric importance. The final section gives a brief summary of the elemental composition of individuals. Focusing on the elements of dosimetric importance, information is presented on the body content of 13 elements: calcium, carbon, chloride, hydrogen, iodine, iron, magnesium, nitrogen, oxygen, potassium, sodium, sulphur, and phosphorus.
[Study on spectrum analysis of X-ray based on rotational mass effect in special relativity].
Yu, Zhi-Qiang; Xie, Quan; Xiao, Qing-Quan
2010-04-01
Based on special relativity, the formation mechanism of characteristic X-ray has been studied, and the influence of rotational mass effect on X-ray spectrum has been given. A calculation formula of the X-ray wavelength based upon special relativity was derived. Error analysis was carried out systematically for the calculation values of characteristic wavelength, and the rules of relative error were obtained. It is shown that the values of the calculation are very close to the experimental values, and the effect of rotational mass effect on the characteristic wavelength becomes more evident as the atomic number increases. The result of the study has some reference meaning for the spectrum analysis of characteristic X-ray in application.
Study of galaxies in the Lynx-Cancer void - VII. New oxygen abundances
NASA Astrophysics Data System (ADS)
Pustilnik, S. A.; Perepelitsyna, Y. A.; Kniazev, A. Y.
2016-11-01
We present new or improved oxygen abundances (O/H) for the nearby Lynx-Cancer void updated galaxy sample. They are obtained via the SAO 6-m telescope spectroscopy (25 objects), or derived from the Sloan Digital Sky Survey spectra (14 galaxies, of which for seven objects O/H values were unknown). For eight galaxies with detected [O III] λ4363 line, O/H values are derived via the direct (Te) method. For the remaining objects, O/H was estimated via semi-empirical and empirical methods. For all accumulated O/H data for 81 galaxies of this void (with 40 of them derived via Te method), their relation `O/H versus MB' is compared with that for similar late-type galaxies from denser environments (the Local Volume `reference sample'). We confirm our previous conclusion derived for a subsample of 48 objects: void galaxies show systematically reduced O/H for the same luminosity with respect to the reference sample, in average by 0.2 dex, or by a factor of ˜1.6. Moreover, we confirm the fraction of ˜20 per cent of strong outliers, with O/H of two to four times lower than the typical values for the `reference' sample. The new data are consistent with the conclusion on the slower evolution of the main void galaxy population. We obtained Hα velocity for the faint optical counterpart of the most gas-rich (M(H I)/LB = 25) void object J0723+3624, confirming its connection with the respective H I blob. For similar extremely gas-rich dwarf J0706+3020, we give a tentative O/H ˜(O/H)⊙/45. In Appendix A, we present the results of calibration of semi-empirical method by Izotov & Thuan and of empirical calibrators by Pilyugin & Thuan and Yin et al. on the sample of ˜150 galaxies from the literature with O/H measured by Te method.
Kalivas, John H; Georgiou, Constantinos A; Moira, Marianna; Tsafaras, Ilias; Petrakis, Eleftherios A; Mousdis, George A
2014-04-01
Quantitative analysis of food adulterants is an important health and economic issue that needs to be fast and simple. Spectroscopy has significantly reduced analysis time. However, still needed are preparations of analyte calibration samples matrix matched to prediction samples which can be laborious and costly. Reported in this paper is the application of a newly developed pure component Tikhonov regularization (PCTR) process that does not require laboratory prepared or reference analysis methods, and hence, is a greener calibration method. The PCTR method requires an analyte pure component spectrum and non-analyte spectra. As a food analysis example, synchronous fluorescence spectra of extra virgin olive oil samples adulterated with sunflower oil is used. Results are shown to be better than those obtained using ridge regression with reference calibration samples. The flexibility of PCTR allows including reference samples and is generic for use with other instrumental methods and food products. Copyright © 2013 Elsevier Ltd. All rights reserved.
Design of two-dimensional zero reference codes with cross-entropy method.
Chen, Jung-Chieh; Wen, Chao-Kai
2010-06-20
We present a cross-entropy (CE)-based method for the design of optimum two-dimensional (2D) zero reference codes (ZRCs) in order to generate a zero reference signal for a grating measurement system and achieve absolute position, a coordinate origin, or a machine home position. In the absence of diffraction effects, the 2D ZRC design problem is known as the autocorrelation approximation. Based on the properties of the autocorrelation function, the design of the 2D ZRC is first formulated as a particular combination optimization problem. The CE method is then applied to search for an optimal 2D ZRC and thus obtain the desirable zero reference signal. Computer simulation results indicate that there are 15.38% and 14.29% reductions in the second maxima value for the 16x16 grating system with n(1)=64 and the 100x100 grating system with n(1)=300, respectively, where n(1) is the number of transparent pixels, compared with those of the conventional genetic algorithm.
Greda, Krzysztof; Swiderski, Krzysztof; Jamroz, Piotr; Pohl, Pawel
2016-09-06
A novel atmospheric pressure glow discharge generated in contact with a flowing liquid anode (FLA-APGD) was developed as the efficient excitation source for the optical emission spectrometry (OES) detection. Differences in the appearance and the electrical characteristic of the FLA-APGD and a conventional system operated with a flowing liquid cathode (FLC-APGD) were studied in detail and discussed. Under the optimal operating conditions for the FLA-APGD, the emission from the analytes (Ag, Cd, Hg, Pb, Tl, and Zn) was from 20 to 120 times higher as compared to the FLC-APGD. Limits of detections (LODs) established with a novel FLA-APGD system were on average 20 times better than those obtained for the FLC-APGD. A further improvement of the LODs was achieved by reducing the background shift interferences and, as a result, the LODs for Ag, Cd, Hg, Pb, Tl, and Zn were 0.004, 0.040, 0.70, 1.7, 0.035, and 0.45 μg L(-1), respectively. The precision of the FLA-APGD-OES method was evaluated to be within 2-5% (as the relative standard deviation of the repeated measurements). The method found its application in the determination of the content of Ag, Cd, Hg, Pb, Tl, and Zn in a certified reference material (CRM) of Lobster hepatopancreas (TORT-2), four brass samples as well as mineral water and tea leaves samples spiked with the analytes. In the case of brass samples, a reference method, i.e., inductively coupled plasma optical emission spectrometry (ICP-OES) was used. A good agreement between the results obtained with FLA-APGD-OES and the certified values for the CRM TORT-2 as well as the reference values obtained with ICP-OES for the brass samples was revealed, indicating the good accuracy of the proposed method. The recoveries obtained for the spiked samples of mineral water and tea leaves were within the range of 97.5-102%.
Watanabe, Hiroshi; Nomura, Yoshikazu; Kuribayashi, Ami; Kurabayashi, Tohru
2018-02-01
We aimed to employ the Radia diagnostic software with the safety and efficacy of a new emerging dental X-ray modality (SEDENTEXCT) image quality (IQ) phantom in CT, and to evaluate its validity. The SEDENTEXCT IQ phantom and Radia diagnostic software were employed. The phantom was scanned using one medical full-body CT and two dentomaxillofacial cone beam CTs. The obtained images were imported to the Radia software, and the spatial resolution outputs were evaluated. The oversampling method was employed using our original wire phantom as a reference. The resultant modulation transfer function (MTF) curves were compared. The null hypothesis was that MTF curves generated using both methods would be in agreement. One-way analysis of variance tests were applied to the f50 and f10 values from the MTF curves. The f10 values were subjectively confirmed by observing the line pair modules. The Radia software reported the MTF curves on the xy-plane of the CT scans, but could not return f50 and f10 values on the z-axis. The null hypothesis concerning the reported MTF curves on the xy-plane was rejected. There were significant differences between the results of the Radia software and our reference method, except for f10 values in CS9300. These findings were consistent with our line pair observations. We evaluated the validity of the Radia software with the SEDENTEXCT IQ phantom. The data provided were semi-automatic, albeit with problems and statistically different from our reference. We hope the manufacturer will overcome these limitations.
Ionization chamber correction factors for MR-linacs
NASA Astrophysics Data System (ADS)
Pojtinger, Stefan; Steffen Dohm, Oliver; Kapsch, Ralf-Peter; Thorwarth, Daniela
2018-06-01
Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0–2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.
Ionization chamber correction factors for MR-linacs.
Pojtinger, Stefan; Dohm, Oliver Steffen; Kapsch, Ralf-Peter; Thorwarth, Daniela
2018-06-07
Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B . The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0-2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.
Expressing analytical performance from multi-sample evaluation in laboratory EQA.
Thelen, Marc H M; Jansen, Rob T P; Weykamp, Cas W; Steigstra, Herman; Meijer, Ron; Cobbaert, Christa M
2017-08-28
To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.
Langrangian model of nitrogen kinetics in the Chattahoochee river
Jobson, H.E.
1987-01-01
A Lagrangian reference frame is used to solve the convection-dispersion equation and interpret water-quality obtained from the Chattahoochee River. The model was calibrated using unsteady concentrations of organic nitrogen, ammonia, and nitrite plus nitrate obtained during June 1977 and verified using data obtained during August 1976. Reaction kinetics of the cascade type are shown to provide a reasonable description of the nitrogen-species processes in the Chattahoochee River. The conceptual model is easy to visualize in the physical sense and the output includes information that is not easily determined from an Eulerian approach, but which is very helpful in model calibration and data interpretation. For example, the model output allows one to determine which data are of most value in model calibration or verification.
NASA Astrophysics Data System (ADS)
Kim, Byung Chan; Park, Seong-Ook
In order to determine exposure compliance with the electromagnetic fields from a base station's antenna in the far-field region, we should calculate the spatially averaged field value in a defined space. This value is calculated based on the measured value obtained at several points within the restricted space. According to the ICNIRP guidelines, at each point in the space, the reference levels are averaged over any 6min (from 100kHz to 10GHz) for the general public. Therefore, the more points we use, the longer the measurement time becomes. For practical application, it is very advantageous to spend less time for measurement. In this paper, we analyzed the difference of average values between 6min and lesser periods and compared it with the standard uncertainty for measurement drift. Based on the standard deviation from the 6min averaging value, the proposed minimum averaging time is 1min.
Observational uncertainty and regional climate model evaluation: A pan-European perspective
NASA Astrophysics Data System (ADS)
Kotlarski, Sven; Szabó, Péter; Herrera, Sixto; Räty, Olle; Keuler, Klaus; Soares, Pedro M.; Cardoso, Rita M.; Bosshard, Thomas; Pagé, Christian; Boberg, Fredrik; Gutiérrez, José M.; Jaczewski, Adam; Kreienkamp, Frank; Liniger, Mark. A.; Lussana, Cristian; Szepszo, Gabriella
2017-04-01
Local and regional climate change assessments based on downscaling methods crucially depend on the existence of accurate and reliable observational reference data. In dynamical downscaling via regional climate models (RCMs) observational data can influence model development itself and, later on, model evaluation, parameter calibration and added value assessment. In empirical-statistical downscaling, observations serve as predictand data and directly influence model calibration with corresponding effects on downscaled climate change projections. Focusing on the evaluation of RCMs, we here analyze the influence of uncertainties in observational reference data on evaluation results in a well-defined performance assessment framework and on a European scale. For this purpose we employ three different gridded observational reference grids, namely (1) the well-established EOBS dataset (2) the recently developed EURO4M-MESAN regional re-analysis, and (3) several national high-resolution and quality-controlled gridded datasets that recently became available. In terms of climate models five reanalysis-driven experiments carried out by five different RCMs within the EURO-CORDEX framework are used. Two variables (temperature and precipitation) and a range of evaluation metrics that reflect different aspects of RCM performance are considered. We furthermore include an illustrative model ranking exercise and relate observational spread to RCM spread. The results obtained indicate a varying influence of observational uncertainty on model evaluation depending on the variable, the season, the region and the specific performance metric considered. Over most parts of the continent, the influence of the choice of the reference dataset for temperature is rather small for seasonal mean values and inter-annual variability. Here, model uncertainty (as measured by the spread between the five RCM simulations considered) is typically much larger than reference data uncertainty. For parameters of the daily temperature distribution and for the spatial pattern correlation, however, important dependencies on the reference dataset can arise. The related evaluation uncertainties can be as large or even larger than model uncertainty. For precipitation the influence of observational uncertainty is, in general, larger than for temperature. It often dominates model uncertainty especially for the evaluation of the wet day frequency, the spatial correlation and the shape and location of the distribution of daily values. But even the evaluation of large-scale seasonal mean values can be considerably affected by the choice of the reference. When employing a simple and illustrative model ranking scheme on these results it is found that RCM ranking in many cases depends on the reference dataset employed.
[Investigation of adolescents' bone metabolism in the western part of Transdanubia].
Csákváry, Violetta; Puskás, Tamás; Bödecs, Tamás; Lôcsei, Zoltán; Oroszlán, György; Kovács, L Gábor; Toldy, Erzsébet
2009-10-25
Childhood reference range based on the age is not available in Hungary, therefore the diagnosis and therapy of bone metabolic diseases of childhood are subject to difficulties. The aim of this work is to provide information about the adolescents' results of bone mineral density and bone biomarkers. Measurements were performed in 169 healthy adolescents (98 girls, 71 boys, age: 17.0+/-1.2 years). Bone mineral content (BMC) and bone mineral density (BMD) of the lumbar spine were measured using Double X-ray Absorptiometry (DXA, LUNAR, GE Health Care, USA) and Z-score values were analyzed using different reference population. In the serum, bone biomarkers osteocalcin (OC) and beta-crosslaps (beta-Cl) were measured by a fully automated, electrochemiluminescence immunoassay method (Elecsys-2010, Roche). Data were analyzed according to gender and the Tanner stage and grade system. Associations between body mass index (BMI), calcium intake, consumption of soft drinks and coke, and physical exercise were investigated. BMC values for both age groups were significantly elevated in boys of the Tanner stage V. (15-16 years: 62.9+/-14.3 g; 17-19 years: 69.8+/-9.3g) than in girls (58.1+/-10.4; 61.6+/-8.5 g) (p<0.001). BMD values were higher in girls, than in boys (1.17+/-0.12 g/cm 2 vs. 1.13+/-0.11 g/cm 2) (p<0.05). OC and beta-Cl levels showed negative correlation with age in both gender (p<0.01), while OC and beta-Cl levels were higher in boys, than in girls (p<0.001). Elevation of BMC and BMD values were associated with increase of BMI in both gender (p<0.05), but the biomarkers in thin girls were higher, than in overweight girls (p<0.05). Authors obtained excellent correlations between the BMD-Z-score values compared to the German standard and to their own population (girls: r=0.97, boys: 0.88), but the absolute values significantly differed from one another. 80% of adolescents are on a diet with insufficient calcium intake, while 38% of them do not play sport regularly. Excessive intake of soft drinks was determined in 60% of adolescents. In the case of insufficient calcium intake (4.7%, 6/127), low bone mass was measured using the Z-score of the German reference values. Among children with adequate calcium intake, BMD assessed by DXA was normal. These data help to determine normal reference values among healthy high school students. Further studies are needed in wider range of young population for the establishment of Hungarian reference values of bone markers.
Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio
2018-06-01
To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.
NASA Astrophysics Data System (ADS)
Grosjean, Romain; Sauer, Benoît; Guerra, Rui; Kermarrec, Isabelle; Ponvianne, Yannick; Winninger, Daniel; Daudon, Michel; Blum, Alain; Felblinger, Jacques; Hubert, Jacques
2007-03-01
The selection of the optimal treatment method for urinary stones diseases depends on the chemical composition of the stone and its corresponding fragility. MDCT has become the most used modality to determine rapidly and accurately the presence of stones when evaluating urinary lithiasis treatment. That is why several studies have tempted to determine the chemical composition of the stones based on the stone X-ray attenuation in-vitro and invivo. However, in-vitro studies did not reproduce the normal abdominal wall and fat, making uncertain the standardization of the obtained values. The aim of this study is to obtain X-ray attenuation values (in Hounsfield Units) of the six more frequent types of human renal stones (n=217) and to analyze the influence of the surrounding media on these values. The stones were first placed in a jelly, which X-ray attenuation is similar to that of the human kidney (30 HU at 120 kV). They were then stuck on a grid, scanned in a water tank and finally scanned in the air. Significant differences in CT-attenuation values were obtained with the three different surrounding media (jelly, water, air). Furthermore there was an influence of the surrounding media and consequently discrepancies in determination of the chemical composition of the renal stones. Consequently, CT-attenuation values found in in-vitro studies cannot really be considered as a reference for the determination of the chemical composition except if the used phantom is an anthropomorphic one.
A testable model of earthquake probability based on changes in mean event size
NASA Astrophysics Data System (ADS)
Imoto, Masajiro
2003-02-01
We studied changes in mean event size using data on microearthquakes obtained from a local network in Kanto, central Japan, from a viewpoint that a mean event size tends to increase as the critical point is approached. A parameter describing changes was defined using a simple weighting average procedure. In order to obtain the distribution of the parameter in the background, we surveyed values of the parameter from 1982 to 1999 in a 160 × 160 × 80 km volume. The 16 events of M5.5 or larger in this volume were selected as target events. The conditional distribution of the parameter was estimated from the 16 values, each of which referred to the value immediately prior to each target event. The distribution of the background becomes a function of symmetry, the center of which corresponds to no change in b value. In contrast, the conditional distribution exhibits an asymmetric feature, which tends to decrease the b value. The difference in the distributions between the two groups was significant and provided us a hazard function for estimating earthquake probabilities. Comparing the hazard function with a Poisson process, we obtained an Akaike Information Criterion (AIC) reduction of 24. This reduction agreed closely with the probability gains of a retrospective study in a range of 2-4. A successful example of the proposed model can be seen in the earthquake of 3 June 2000, which is the only event during the period of prospective testing.
Histomorphometric reference data of transiliac bone biopsy in children from 8 to 17 years old.
Velásquez-Forero, Francisco H; Jiménez-Brau, Daniel A; Esparza-García, Mariela
2018-01-01
Histomorphometric analysis of bone samples is a key tool for studying bone metabolism; however, only a few pediatric reference data exist. The aim of the present study is to report more reference data and to investigate if histomorphometric differences exist between age and gender. We obtained 19 transiliac bone samples previously marked with tetracycline, from children between 8 and 17 years (13 were male), with normal blood test results and urine biochemical bone markers. We evaluated bone histomorphometric parameters using a digitalizing table with osteomeasure to obtain normative data of means and standard deviations, as well as median and range. Due to the small sample, a Monte Carlo simulation was applied. Structural, static, dynamic, and resorptic histomorphometric parameters were evaluated by age and gender following the American Society for Bone and Mineral Research recommendations. Bone volume (in the older children) and mineral apposition rate (in the younger children), the eroded surface (in boys), and the new bone wall thickness (in girls) were significantly increased. On the trabecular area of mineralization front, the modeling and the remodeling bone formation were similar (16 and 18%). The rest of the histomorphometric bone parameters by age and gender showed no significant difference. In healthy children, these bone histomorphometric findings, with these techniques and for this ages could be used as reference values. Copyright: © 2018 Permanyer.
Feng, Lei; Fang, Hui; Zhou, Wei-Jun; Huang, Min; He, Yong
2006-09-01
Site-specific variable nitrogen application is one of the major precision crop production management operations. Obtaining sufficient crop nitrogen stress information is essential for achieving effective site-specific nitrogen applications. The present paper describes the development of a multi-spectral nitrogen deficiency sensor, which uses three channels (green, red, near-infrared) of crop images to determine the nitrogen level of canola. This sensor assesses the nitrogen stress by means of estimated SPAD value of the canola based on canola canopy reflectance sensed using three channels (green, red, near-infrared) of the multi-spectral camera. The core of this investigation is the calibration methods between the multi-spectral references and the nitrogen levels in crops measured using a SPAD 502 chlorophyll meter. Based on the results obtained from this study, it can be concluded that a multi-spectral CCD camera can provide sufficient information to perform reasonable SPAD values estimation during field operations.
Mojto, V; Gvozdjakova, A; Kucharska, J; Rausova, Z; Vancova, O; Valuch, J
2018-01-01
The aim of the study was to observe the influence of 11-days complete water fasting (WF) and regeneration diet (RD) on renal function, body weight, blood pressure and oxidative stress. Therapeutic WF is considered a healing method. Ten volunteers drank only water for 11 days, followed by RD for the next 11 days. Data on body weight, blood pressure, kidney functions, antioxidants, lipid peroxidation, cholesterols, triacylglycerols and selected biochemical parameters were obtained. WF increased uric acid and creatinine and decreased glomerular filtration rate. After RD, the parameters were comparable to baseline values. Urea was not affected. Lipid peroxidation (TBARS) decreased and maintained stable after RD. Fasting decreased α-tocopherol and increased γ-tocopherol, no significant changes were found after RD. Coenzyme Q10 decreased after RD. HDL-cholesterol decreased in WF. Total- and LDL-cholesterol decreased after RD. Other biochemical parameters were within the range of reference values. The effect of the complete fasting on kidney function was manifested by hyperuricemia. Renal function was slightly decreased, however maintained within the reference values. After RD, it returned to baseline values. The positive effect of the complete water fasting was in the reduction of oxidative stress, body weight and blood pressure (Tab. 3, Ref. 25).
Cusack, Lara; Field, Cara L; Hoopes, Lisa; McDermott, Alexa; Clauss, Tonya
2016-06-01
Though one of the most widely kept elasmobranchs in human care, the cownose ray (CNR; Rhinoptera bonasus ), remains a species with minimal published information on hematologic reference intervals. As part of a larger study investigating the health and nutrition of the CNR, this study established a preliminary data set of plasma chemistry and hematology values specific to animals recently caught from the wild and compared this data set (intake sample) to values obtained following a period of quarantine (27-40 days) in an aquarium (exit sample). Blood samples were collected from 47 wild female (n = 46) and male (n = 1) CNR caught in pound nets off the coast of North Carolina and South Carolina. Differences between intake and exit values were analyzed. Due to the preponderance of female animals, data were not analyzed for sex differences. Plasma biochemical profiles were performed and analyzed. A select number of complete blood cell counts were performed (n = 24 from 12 animals). Statistically significant differences (P < 0.05) specific to time of sampling were determined for packed cell volume, total solids, blood urea nitrogen, sodium, chloride, potassium, phosphorus, cholesterol, glucose, and aspartate aminotransferase. Values reported are a significant expansion on the existing limited data for CNRs and will serve as a reference for health assessment of individuals both in the wild and in exhibit populations.
Measurement at low strain rates of the elastic properties of dental polymeric materials.
Chabrier, F; Lloyd, C H; Scrimgeour, S N
1999-01-01
To evaluate a simple static test (i.e. a slow strain rate test) designed to measure Young's modulus and the bulk modulus of polymeric materials (The NOL Test). Though it is a 'mature' test as yet it has never been applied to dental materials. A small cylindrical specimen is contained in a close-fitting steel constraining ring and compressive force applied to the ends by steel pistons. The initial (unconstrained) deformation is controlled by Young's modulus. Lateral spreading leads to constraint from the ring and subsequent deformation is controlled by the bulk modulus. A range of dental materials and reference polymers were selected and both moduli measured. From these data Poisson's ratios were calculated. The test proved be a simple reliable method for obtaining values for these properties. For composite the value of Young's modulus was lower, bulk modulus relatively similar and Poisson's ratio higher than that obtained from high strain rate techniques (as expected for a strain rate sensitive material). This test does fulfil a requirement for a simple test to define fully the elastic properties of dental polymeric materials. Measurements are made at the strain rates used in conventional static tests and values reflect this test condition. The higher values obtained for Poisson's ratio at this slow strain rate has implications for FEA, in that analysis is concerned with static or slow rate loading situations.
The Study and Measurement of Values and Attitudes.
ERIC Educational Resources Information Center
Kerlinger, Fred N.
The author defines values, attitudes, and beliefs according to their relation to referents. A referent is a construct standing for a set or category of social objects, ideas, or behaviors that is the focus of an attitude. Attitudes and values are belief systems. Beliefs are enduring cognitions about referents; beliefs reflect the value and…
USDA-ARS?s Scientific Manuscript database
Nutrient reference values have significant public health and policy implications. Given the importance of defining reliable nutrient reference values, there is a need for an explicit, objective, and transparent process to set these values. The Tufts Medical Center Evidence-based Practice Center asse...
Air density correction in ionization dosimetry.
Christ, G; Dohm, O S; Schüle, E; Gaupp, S; Martin, M
2004-05-21
Air density must be taken into account when ionization dosimetry is performed with unsealed ionization chambers. The German dosimetry protocol DIN 6800-2 states an air density correction factor for which current barometric pressure and temperature and their reference values must be known. It also states that differences between air density and the attendant reference value, as well as changes in ionization chamber sensitivity, can be determined using a radioactive check source. Both methods have advantages and drawbacks which the paper discusses in detail. Barometric pressure at a given height above sea level can be determined by using a suitable barometer, or data downloaded from airport or weather service internet sites. The main focus of the paper is to show how barometric data from measurement or from the internet are correctly processed. Therefore the paper also provides all the requisite equations and terminological explanations. Computed and measured barometric pressure readings are compared, and long-term experience with air density correction factors obtained using both methods is described.
Microwave assisted extraction for trace element analysis of plant materials by ICP-AES.
Borkowska-Burnecka, J
2000-11-01
Application of microwave assisted extraction for the decomposition and dissolution of plant samples for trace metal determination by ICP-AES was examined. Dried onion, leaves of spinach beet and three reference materials CTA-OTL-1, CTA-VTL-2 and CL-1 were analyzed. Water, EDTA and hydrochloric acid (0.01, 0.10 and 1.0 M, respectively) were used as leaching solutions. The extraction efficiency was investigated by comparison of the results with those obtained after microwave wet digestion. HCl was found to be very suitable for quantitative extraction of B, Ba, Cd, Cu, Mn, Ni, Pb, Sr and Zn from the samples. For reference materials, the measured concentrations are well consistent with the certified values. The use of EDTA led to a complete extraction of B, Cd, Ni, Pb, Sr and Zn. Water was found to be a good leaching solution for boron. For extraction with HCl and EDTA, the RSD values for the concentrations measured were below 8% for most of the elements.
Herkovits, Jorge; Perez-Coll, Cristina; Herkovits, Francisco D
2002-01-01
The toxicity of 34 environmental samples from potentially polluted and reference stations were evaluated by means of the AMPHITOX test from acute to chronic exposure according to the toxicity found in each sample. The samples were obtained from surface and ground water, leaches, industrial effluents and soils. The data, expressed in acute, short-term chronic and chronic Toxicity Units (TUa, TUstc and TUc) resulted in a maximal value of 1000 TUc, found in a leach, while the lower toxicity value was 1.4 TUa corresponding to two surface water samples. In five samples (four providing from reference places) no toxicity was detected. The results point out the possibility of evaluating the toxicity of a wide diversity of samples by means of AMPHITOX as a customized toxicity test. The fact that almost all samples with suspected toxicity in rivers and streams from the Metropolitan area of Buenos Aires city resulted toxic, indicates the need of enhanced stewardship of chemical substances for environmental and human health protection purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brownlee, R.T.; Shehan, B.P.; Wedd, A.G.
1987-07-01
Variable-temperature NMR line width measurements of ZVMo and UN in aqueous solutions of K4(Mo(CN)8) x 2H2O indicate that the stereochemistry of the (Mo(CN)8)U ion in solution is dodecahedral. A value for the ZVMo quadrupole coupling constant of 3.61 MHz is obtained. 27 references, 1 figure, 1 table.
Effect of synthesis methods on the Ca{sub 3}Co{sub 4}O{sub 9} thermoelectric ceramic performances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sotelo, A.; Rasekh, Sh.; Torres, M.A.
2015-01-15
Three different synthesis methods producing nanometric grain sizes, coprecipitation with ammonium carbonate, oxalic acid, and by attrition milling have been studied to produce Ca{sub 3}Co{sub 4}O{sub 9} ceramics and compared with the classical solid state route. These three processes have produced high reactive precursors and all the organic material and CaCO{sub 3}·have been decomposed in a single thermal treatment. Coprecipitation leads to pure Ca{sub 3}Co{sub 4}O{sub 9} phase, while attrition milling and classical solid state produce small amounts of Ca{sub 3}Co{sub 2}O{sub 6} secondary phase. Power factor values are similar for all three samples, being slightly lower for the onesmore » produced by attrition milling. These values are much higher than the obtained in samples prepared by the classical solid state method, used as reference. The maximum power factor values determined at 800 °C (∼0.43 mW/K{sup 2} m) are slightly higher than the best reported values obtained in textured ones which also show much higher density values. - Graphical abstract: Impressive raise of PF in Ca{sub 3}Co{sub 4}O{sub 9} thermoelectric materials obtained from nanometric grains. - Highlights: • Ca{sub 3}Co{sub 4}O{sub 9} has been produced by four different methods. • Precursors particle sizes influences on the final performances. • Coprecipitation methods produce single Ca{sub 3}Co{sub 4}O{sub 9} phase. • Power factor reaches values comparable to high density textured materials.« less
High-resolution diapycnal mixing map of the Alboran Sea thermocline from seismic reflection images
NASA Astrophysics Data System (ADS)
Mojica, Jhon F.; Sallarès, Valentí; Biescas, Berta
2018-06-01
The Alboran Sea is a dynamically active region where the salty and warm Mediterranean water first encounters the incoming milder and cooler Atlantic water. The interaction between these two water masses originates a set of sub-mesoscale structures and a complex sequence of processes that entail mixing close to the thermocline. Here we present a high-resolution map of the diapycnal diffusivity around the thermocline depth obtained using acoustic data recorded with a high-resolution multichannel seismic system. The map reveals a patchy thermocline, with spots of strong diapycnal mixing juxtaposed with areas of weaker mixing. The patch size is of a few kilometers in the horizontal scale and of 10-15 m in the vertical one. The comparison of the obtained maps with the original acoustic images shows that mixing tends to concentrate in areas where internal waves, which are ubiquitous in the surveyed area, become unstable and shear instabilities develop, enhancing energy transfer towards the turbulent regime. These results are also compared with others obtained using more conventional oceanographic probes. The values estimated based on the seismic data are within the ranges of values obtained from oceanographic data analysis, and they are also consistent with reference theoretical values. Overall, our results demonstrate that high-resolution seismic systems allow the remote quantification of mixing at the thermocline depth with unprecedented resolution.
Discussion on Comprehensive Utilization Value of Scutellaria Baicalensis Flower
NASA Astrophysics Data System (ADS)
Song, Yagang; Miao, Mingsan
2018-01-01
The chemical constituents of Scutellaria baicalensis flower are flavonoids, volatile oils and melanin, It has anti-tumor, anti-inflammatory, antioxidant, anti angiogenic and antithrombotic pharmacological effects, and it has the effect of clearing away heat and relieving lung fire. Scutellaria baicalensis flower is rich in resources, cheap, easy to obtain, accurate effect, With the prevention and treatment of a variety of diseases. In this paper, the ancient application, chemical constituents, pharmacological actions and comprehensive utilization of Scutellaria baicalensis flower were reviewed, The purpose of this study was to explore the value of its development and utilization, so as to provide reference for the comprehensive utilization of Scutellaria baicalensis flower.
Huy, Ngo Quang; Binh, Do Quang
2014-12-01
This work suggests a method for determining the activities of cylindrical radioactive samples. The self-attenuation factor was applied for providing the self-absorption correction of gamma rays in the sample material. The experimental measurement of a (238)U reference sample and the calculation using the MCNP5 code allow obtaining the semi-empirical formulae of detecting efficiencies for the gamma energies ranged from 185 to 1764keV. These formulae were used to determine the activities of the (238)U, (226)Ra, (232)Th, (137)Cs and (40)K nuclides in the IAEA RGU-1, IAEA-434, IAEA RGTh-1, IAEA-152 and IAEA RGK-1 radioactive standards. The coincidence summing corrections for gamma rays in the (238)U and (232)Th series were applied. The activities obtained in this work were in good agreement with the reference values. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Eades, J. B., Jr.
1974-01-01
The mathematical developments carried out for this investigation are reported. In addition to describing and discussing the solutions which were acquired, there are compendia of data presented herein which summarize the equations and describe them as representative trace geometries. In this analysis the relative motion problems have been referred to two particular frames of reference; one which is inertially aligned, and one which is (local) horizon oriented. In addition to obtaining the classical initial values solutions, there are results which describe cases having applied specific forces serving as forcing functions. Also, in order to provide a complete state representation the speed components, as well as the displacements, have been described. These coordinates are traced on representative planes analogous to the displacement geometries. By this procedure a complete description of a relative motion is developed; and, as a consequence range rate as well as range information is obtained.
Blood platelet counts, morphology and morphometry in lions, Panthera leo.
Du Plessis, L
2009-09-01
Due to logistical problems in obtaining sufficient blood samples from apparently healthy animals in the wild in order to establish normal haematological reference values, only limited information regarding the blood platelet count and morphology of free-living lions (Panthera leo) is available. This study provides information on platelet counts and describes their morphology with particular reference to size in two normal, healthy and free-ranging lion populations. Blood samples were collected from a total of 16 lions. Platelet counts, determined manually, ranged between 218 and 358 x 10(9)/l. Light microscopy showed mostly activated platelets of various sizes with prominent granules. At the ultrastructural level the platelets revealed typical mammalian platelet morphology. However, morphometric analysis revealed a significant difference (P < 0.001) in platelet size between the two groups of animals. Basic haematological information obtained in this study may be helpful in future comparative studies between animals of the same species as well as in other felids.
[New non-volumetric method for estimating peroperative blood loss].
Tachoires, D; Mourot, F; Gillardeau, G
1979-01-01
The authors have developed a new method for the estimation of peroperative blood loss by measurement of the haematocrit of a fluid obtained by diluting the blood from swabs in a known volume of isotonic saline solution. This value, referred to a monogram, may be used to assess the volume of blood impregnating the compresses, in relation to the pre-operative or present haematocrit of the patient, by direct reading. The precision of the method is discussed. The results obtained justified its routine application in surgery in children, patients with cardiac failure and in all cases requiring precise compensation of per-operative blood loss.
Serum proteins by capillary zone electrophoresis: approaches to the definition of reference values.
Petrini, C; Alessio, M G; Scapellato, L; Brambilla, S; Franzini, C
1999-10-01
The Paragon CZE 2000 (Beckman Analytical, Milan, Italy) is an automatic dedicated capillary zone electrophoresis (CZE) system, producing a five-zone serum protein pattern with quantitative estimation of the zones. With the view of substituting this instrument for two previously used serum protein electrophoresis techniques, we planned to produce reference values for the "new" systems leading to compatible interpretation of the results. High resolution cellulose acetate electrophoresis with visual inspection and descriptive reporting (HR-CAE) and five-zone cellulose acetate electrophoresis with densitometry (CAE-D) were the previously used techniques. Serum samples (n = 167) giving "normal pattern" with HR-CAE were assayed with the CZE system, and the results were statistically assessed to yield 0.95 reference intervals. One thousand normal and pathological serum samples were then assayed with the CAE-D and the CZE techniques, and the regression equations of the CAE-D values over the CZE values for the five zones were used to transform the CAE-D reference limits into the CZE reference limits. The two sets of reference values thereby produced were in good agreement with each other and also with reference values previously reported for the CZE system. Thus, reference values for the CZE techniques permit interpretation of results coherent with the previously used techniques and reporting modes.
Isotopic and trace element variability in altered and unaltered tuffs at Yucca Mountain, Nevada
Peterman, Z.E.; Spengler, R.W.; Singer, F.R.; Dickerson, R.P.
1993-01-01
Reference stratigraphic sections near Yucca Mountain, Nevada were established and sampled in outcrop areas where the volcanic rocks have been minimally altered. Isotopic and trace element analyses obtained for these reference sections are baseline data for assessing the degree and extent of element mobility attendant with past zonal alteration of the rock mass. In agreement with earlier studies, zeolitization is shown to have occurred under wholesale open-system conditions. Calcium was increased by two three times the baseline values and strontium up to twenty times. In contrast, barium displays less variability, and the high-field strength elements zirconium and titanium were the least mobile during zeolitization. The data reported here establish the usefulness of reference sections of assessing past elements mobility. The information gained will be helpful in predicting possible future element mobility induced by thermally activated fluids in the near field of a potential repository.
Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?
NASA Astrophysics Data System (ADS)
De Coste, Vanessa; Francescon, Paolo; Marinelli, Marco; Masi, Laura; Paganini, Lucia; Pimpinella, Maria; Prestopino, Giuseppe; Russo, Serenella; Stravato, Antonella; Verona, Claudio; Verona-Rinati, Gianluca
2017-09-01
A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, kQMD , was calculated for the MD, and the small field output correction factors, k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} , were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental kQMD values are in agreement within 1% with the MC calculated ones. Output correction factors within +0.7% and -1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.
Upper arm circumference development in Chinese children and adolescents: a pooled analysis.
Tong, Fang; Fu, Tong
2015-05-30
Upper arm development in children is different in different ethnic groups. There have been few reports on upper arm circumference (UAC) at different stages of development in children and adolescents in China. The purpose of this study was to provide a reference for growth with weighted assessment of the overall level of development. Using a pooled analysis, an authoritative journal database search and reports of UAC, we created a new database on developmental measures in children. In conducting a weighted analysis, we compared reference values for 0~60 months of development according to the World Health Organization (WHO) statistics considering gender and nationality and used Z values as interval values for the second sampling to obtain an exponential smooth curve to analyze the mean, standard deviation, and sites of attachment. Ten articles were included in the pooled analysis, and these articles included participants from different areas of China. The point of intersection with the WHO curve was 3.5 years with higher values at earlier ages and lower values at older ages. Boys curve was steeper after puberty. The curves in the studies had a merged line compatible. The Z values of exponential smoothing showed the curves were similar for body weight and had a right normal distribution. The integrated index of UAC in Chinese children and adolescents indicated slightly variations with regions. Exponential curve smoothing was suitable for assessment at different developmental stages.
Slomka, Piotr J; Alexanderson, Erick; Jácome, Rodrigo; Jiménez, Moises; Romero, Edgar; Meave, Aloha; Le Meunier, Ludovic; Dalhbom, Magnus; Berman, Daniel S; Germano, Guido; Schelbert, Heinrich
2012-02-01
Several models for the quantitative analysis of myocardial blood flow (MBF) at stress and rest and myocardial flow reserve (MFR) with (13)N-ammonia myocardial perfusion PET have been implemented for clinical use. We aimed to compare quantitative results obtained from 3 software tools (QPET, syngo MBF, and PMOD), which perform PET MBF quantification with either a 2-compartment model (QPET and syngo MBF) or a 1-compartment model (PMOD). We considered 33 adenosine stress and rest (13)N-ammonia studies (22 men and 11 women). Average age was 54.5 ± 15 y, and average body mass index was 26 ± 4.2. Eighteen patients had a very low likelihood of disease, with no chest pain, normal relative perfusion results, and normal function. All data were obtained on a PET/CT scanner in list mode with CT attenuation maps. Sixteen dynamic frames were reconstructed (twelve 10-s, two 30-s, one 1-min, and one 6-min frames). Global and regional stress and rest MBF and MFR values were obtained with each tool. Left ventricular contours and input function region were obtained automatically in system QPET and syngo MBF and manually in PMOD. The flow values and MFR values were highly correlated among the 3 packages (R(2) ranging from 0.88 to 0.92 for global values and from 0.78 to 0.94 for regional values. Mean reference MFR values were similar for QPET, syngo MBF, and PMOD (3.39 ± 1.22, 3.41 ± 0.76, and 3.66 ± 1.19, respectively) by 1-way ANOVA (P = 0.74). The lowest MFR in very low likelihood patients in any given vascular territory was 2.25 for QPET, 2.13 for syngo MBF, and 2.23 for PMOD. Different implementations of 1- and 2-compartment models demonstrate an excellent correlation in MFR for each vascular territory, with similar mean MFR values.
Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao
2017-11-27
Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.
NASA Astrophysics Data System (ADS)
Martínez-González, A.; Moreno-Hernández, D.; Monzón-Hernández, D.; León-Rodríguez, M.
2017-06-01
In the schlieren method, the deflection of light by the presence of an inhomogeneous medium is proportional to the gradient of its refractive index. Such deflection, in a schlieren system, is represented by light intensity variations on the observation plane. Then, for a digital camera, the intensity level registered by each pixel depends mainly on the variation of the medium refractive index and the status of the digital camera settings. Therefore, in this study, we regulate the intensity value of each pixel by controlling the camera settings such as exposure time, gamma and gain values in order to calibrate the image obtained to the actual temperature values of a particular medium. In our approach, we use a color digital camera. The images obtained with a color digital camera can be separated on three different color-channels. Each channel corresponds to red, green, and blue color, moreover, each one has its own sensitivity. The differences in sensitivity allow us to obtain a range of temperature values for each color channel. Thus, high, medium and low sensitivity correspond to green, blue, and red color channel respectively. Therefore, by adding up the temperature contribution of each color channel we obtain a wide range of temperature values. Hence, the basic idea in our approach to measure temperature, using a schlieren system, is to relate the intensity level of each pixel in a schlieren image to the corresponding knife-edge position measured at the exit focal plane of the system. Our approach was applied to the measurement of instantaneous temperature fields of the air convection caused by a heated rectangular metal plate and a candle flame. We found that for the metal plate temperature measurements only the green and blue color-channels were required to sense the entire phenomena. On the other hand, for the candle case, the three color-channels were needed to obtain a complete measurement of temperature. In our study, the candle temperature was took as reference and it was found that the maximum temperature value obtained for green, blue and red color-channel was ∼275.6, ∼412.9, and ∼501.3 °C, respectively.
The Geochemical Databases GEOROC and GeoReM - What's New?
NASA Astrophysics Data System (ADS)
Sarbas, B.; Jochum, K. P.; Nohl, U.; Weis, U.
2017-12-01
The geochemical databases GEOROC (http: georoc.mpch-mainz.gwdg.de) and GeoReM (http: georem.mpch-mainz.gwdg.de) are maintained by the Max Planck Institute for Chemistry in Mainz, Germany. Both online databases became crucial tools for geoscientists from different research areas. They are regularly upgraded by new tools and new data from recent publications obtained from a wide range of international journals. GEOROC is a collection of published analyses of volcanic rocks and mantle xenoliths. Since recently, data for plutonic rocks are added. The analyses include major and trace element concentrations, radiogenic and non-radiogenic isotope ratios as well as analytical ages for whole rocks, glasses, minerals and inclusions. Samples come from eleven geological settings and span the whole geological age scale from Archean to Recent. Metadata include, among others, geographic location, rock class and rock type, geological age, degree of alteration, analytical method, laboratory, and reference. The GEOROC web page allows selection of samples by geological setting, geography, chemical criteria, rock or sample name, and bibliographic criteria. In addition, it provides a large number of precompiled files for individual locations, minerals and rock classes. GeoReM is a database collecting information about reference materials of geological and environmental interest, such as rock powders, synthetic and natural glasses as well as mineral, isotopic, biological, river water and seawater reference materials. It contains published data and compilation values (major and trace element concentrations and mass fractions, radiogenic and stable isotope ratios). Metadata comprise, among others, uncertainty, analytical method and laboratory. Reference materials are important for calibration, method validation, quality control and to establish metrological traceability. GeoReM offers six different search strategies: samples or materials (published values), samples (GeoReM preferred values), chemical criteria, chemical criteria based on bibliography, bibliography, as well as methods and institutions.
Toulon, Pierre; Berruyer, Micheline; Brionne-François, Marie; Grand, François; Lasne, Dominique; Telion, Caroline; Arcizet, Julien; Giacomello, Roberta; De Pooter, Neila
2016-07-04
Understanding of developmental haemostasis is critical to ensure optimal prevention, diagnosis, and treatment of haemorrhagic and thrombotic diseases in children. As coagulation test results are known to be dependent on the reagents/analysers used, it is recommended for each laboratory to define the age-dependent reference ranges by using its own technical condition. That study was carried out in seven centers to establish age-specific reference ranges using the same reagents and analyser. Plasma samples were obtained from 1437 paediatric patients from the following age groups: 15 days-4 weeks (n=36), 1-5 months (n=320), 6-12 months (n=176), 1-5 years (n=507), 6-10 years (n=132) and 11-17 years (n=262). Indication of coagulation testing was pre-operative screening for non-acute diseases in most cases. PT values were similar in the different age groups to those in adults, whereas longer aPTTs were demonstrated in the younger children. Plasma levels of all clotting factors, except for FV, were significantly decreased (p<0.0001) in the youngest children, adult values being usually reached before the end of the first year. The same applied to antithrombin, protein C/S, and plasminogen. In contrast, FVIII and VWF levels were elevated in the youngest children and returned to adult values within six months. The same applied to D-dimer levels, which were found elevated, particularly until six months of life, until puberty. These data suggest that most coagulation test results are highly dependent on age, mainly during the first year of life, and that age-specific reference ranges must be used to ensure proper evaluation of coagulation in children.
Application of metabolomics: Focus on the quantification of organic acids in healthy adults
Tsoukalas, Dimitris; Alegakis, Athanasios; Fragkiadaki, Persefoni; Papakonstantinou, Evangelos; Nikitovic, Dragana; Karataraki, Aikaterini; Nosyrev, Alexander E.; Papadakis, Emmanouel G.; Spandidos, Demetrios A.; Drakoulis, Nikolaos; Tsatsakis, Aristides M.
2017-01-01
Metabolomics, a 'budding' discipline, may accurately reflect a specific phenotype which is sensitive to genetic and epigenetic interactions. This rapidly evolving field in science has been proposed as a tool for the evaluation of the effects of epigenetic factors, such as nutrition, environment, drug and lifestyle on phenotype. Urine, being sterile, is easy to obtain and as it contains metabolized or non-metabolized products, is a favored study material in the field of metabolomics. Urine organic acids (OAs) reflect the activity of main metabolic pathways and have been used to assess health status, nutritional status, vitamin deficiencies and response to xenobiotics. To date, a limited number of studies have been performed which actually define reference OA values in a healthy population and as reference range for epigenetic influences, and not as a reference to congenital metabolic diseases. The aim of the present study was thus the determination of reference values (RVs) for urine OA in a healthy adult population. Targeted metabolomics analysis of 22 OAs in the urine of 122 healthy adults by gas chromatography-mass spectrometry, was conducted. Percentile distributions of the OA concentrations in urine, as a base for determining the RVs in the respective population sample, were used. No significant differences were detected between female and male individuals. These findings can facilitate the more sensitive determination of OAs in pathological conditions. Therefore, the findings of this study may contribute or add to the information already available on urine metabolite databases, and may thus promote the use of targeted metabolomics for the evaluation of OAs in a clinical setting and for pathophysiological evaluation. However, further studies with well-defined patients groups exhibiting specific symptoms or diseases are warranted in order to discern between normal and pathological values. PMID:28498405
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-01-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions. PMID:18702449
Diemer, J; Quétel, C R; Taylor, P D P
2002-09-01
The contribution of the Institute for Reference Materials and Measurements to the certification of the B, Cd, Cu, Mg, and Pb content of a synthetic water sample used in Comparison 12 of the International Measurement Evaluation Programme (IMEP-12) is described. The aim of the IMEP programme is to demonstrate objectively the degree of equivalence and quality of chemical measurements of individual laboratories on the international scene by comparing them with reference ranges traceable to the SI (Système International d'Unités). IMEP is organized in support of European Union policies and helps to improve the traceability of values produced by field chemical measurement laboratories. The analytical procedure used to establish the reference values for the B, Cd, Cu, Mg, and Pb content of the IMEP-12 sample is based on inductively coupled plasma-isotope-dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. The measurements performed for the IMEP-12 study are described in detail. Focus is on the element boron, which is particularly difficult to analyze by ICP-MS because of potential problems of low sensitivity, high mass discrimination, memory effects, and abundance sensitivity. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO (International Organization for Standardization) and Eurachem guidelines. For all investigated elements with concentrations in the low micro g kg(-1) and mg kg(-1) range (corresponding to pmol kg(-1) to the high micro mol kg(-1) level), SI-traceable reference values with relative expanded uncertainties ( k=2) of less than 2 % were obtained.
Cheng, Xiaofei; Ni, Bin; Liu, Qi; Chen, Jinshui; Guan, Huapeng
2013-01-01
The goal of this study was to determine which paraspinal approach provided a better transverse screw angle (TSA) for each vertebral level in lower lumbar surgery. Axial computed tomography (CT) images of 100 patients, from L3 to S1, were used to measure the angulation parameters, including transverse pedicle angle (TPA) and transverse cleavage plane angle (TCPA) of entry from the two approaches. The difference value between TCPA and TPA, defined as difference angle (DA), was calculated. Statistical differences of DA obtained by the two approaches and the angulation parameters between sexes, and the correlation between each angulation parameter and age or body mass index (BMI) were analyzed. TPA ranged from about 16° at L3 to 30° at S1. TCPA through the Wiltse's and Weaver's approach ranged from about -10° and 25° at L3 to 12° and 32° at S1, respectively. The absolute values of DA through the Weaver's approach were significantly lower than those through the Wiltse's approach at each level. The angulation parameters showed no significant difference with sex and no significant correlation with age or BMI. In the lower lumbar vertebrae (L3-L5) and S1, pedicle screw placement through the Weaver's approach may more easily yield the preferred TSA consistent with TPA than that through the Wiltse's approach. The reference values obtained in this paper may be applied regardless of sex, age or BMI and the descriptive statistical results may be used as references for applying the two paraspinal approaches.
Pintus, M A; Gaspa, G; Nicolazzi, E L; Vicario, D; Rossoni, A; Ajmone-Marsan, P; Nardone, A; Dimauro, C; Macciotta, N P P
2012-06-01
The large number of markers available compared with phenotypes represents one of the main issues in genomic selection. In this work, principal component analysis was used to reduce the number of predictors for calculating genomic breeding values (GEBV). Bulls of 2 cattle breeds farmed in Italy (634 Brown and 469 Simmental) were genotyped with the 54K Illumina beadchip (Illumina Inc., San Diego, CA). After data editing, 37,254 and 40,179 single nucleotide polymorphisms (SNP) were retained for Brown and Simmental, respectively. Principal component analysis carried out on the SNP genotype matrix extracted 2,257 and 3,596 new variables in the 2 breeds, respectively. Bulls were sorted by birth year to create reference and prediction populations. The effect of principal components on deregressed proofs in reference animals was estimated with a BLUP model. Results were compared with those obtained by using SNP genotypes as predictors with either the BLUP or Bayes_A method. Traits considered were milk, fat, and protein yields, fat and protein percentages, and somatic cell score. The GEBV were obtained for prediction population by blending direct genomic prediction and pedigree indexes. No substantial differences were observed in squared correlations between GEBV and EBV in prediction animals between the 3 methods in the 2 breeds. The principal component analysis method allowed for a reduction of about 90% in the number of independent variables when predicting direct genomic values, with a substantial decrease in calculation time and without loss of accuracy. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Bel Hadj Hmida, Y; Tahri, N; Sellami, A; Yangui, N; Jlidi, R; Beyrouti, M I; Krichen, M S; Masmoudi, H
2001-01-01
In order to determine the sensitivity of CEA in the diagnosis of colo-rectal carcinoma, we studied a series of 48 patients with colo-rectal carcinoma (1992-1996). The sensitivity was at 52% with a reference value of 5 ng/ml and 68.7% for a reference value of 2.5 ng/ml. With a reference value of 5 ng/ml, the sensitivity of CEA was at 37% only for patients with colo-rectal carcinoma at Dukes B stage, 66.6% for patients at stage C and 75% for patients at stage D. The dosage of CEA was carried out with a sandwich immunoenzymatic technique in tube. There is no statistic significant correlation between the pre-operative rate of CEA and the localisation of the tumor and its histologic type; in contrast, it was significantly correlated with the ganglionnary metastasis. A significant relationship between the pre-operative rate of CEA and the Dukes stage was found for a reference value of 10 ng/ml but not for a reference value of 5 ng/ml. We calculated the specificity of the CEA for the cancers of colon and rectum which was at 76.98% with a reference value of 5 ng/ml and 86% with a reference value of 10 ng/ml.
Hamstring-and-Lower-Back Flexibility in Male Amateur Soccer Players.
van der Horst, Nick; Priesterbach, Annique; Backx, Frank; Smits, Dirk-Wouter
2017-01-01
This study investigated the hamstring-and-lower-back flexibility (HLBF) of male adult amateur soccer players, using the sit-and-reach test (SRT), with a view to obtaining population-based reference values and to determining whether SRT scores are associated with player characteristics. Cross-sectional cohort study. Teams from high-level Dutch amateur soccer competitions were recruited for participation. Dutch male high-level amateur field soccer players (n = 449) of age 18 to 40 years. Players with a hamstring injury at the moment of SRT-measurement or any other injury that prevented them from following the SRT protocol were excluded. Sit-and-reach test scores were measured and then population-based reference values were calculated as follows: >2SD below mean (defining "very low" HLBF), 1SD-2SD below mean ("low" HLBF), 1SD below mean to 1SD above mean ("normal" HLBF), 1SD-2SD above mean ("high" HLBF), and >2SD above mean ("very high" HLBF). Whether SRT scores were correlated with player characteristics was determined using a Pearson correlation coefficient or Spearman rho. Sit-and-reach test scores ranged from 0 to 43.5 cm (mean 22.0 cm, SD 9.2). The cutoff points for population-based reference values were <3.5 cm for "very low", 3.5 to 13.0 cm for "low", 13.0 to 31.0 cm for "normal", 31.0 to 40.5 cm for "high", and >40.5 cm for "very high". Sit-and-reach test scores were significantly associated with players' height (ρ = -0.132, P = 0.005), body mass index (r = 0.114, P = 0.016), and history of anterior cruciate ligament surgery (P < 0.001). This study is the first to describe the HLBF of amateur soccer players. The SRT reference values with cutoff points may facilitate evidence-based decision making regarding HLBF, and the SRT might be a useful tool to assess injury risk, performance, or for diagnostic purposes.
NASA Technical Reports Server (NTRS)
Mather, R. S.; Lerch, F. J.; Rizos, C.; Masters, E. G.; Hirsch, B.
1978-01-01
The 1977 altimetry data bank is analyzed for the geometrical shape of the sea surface expressed as surface spherical harmonics after referral to the higher reference model defined by GEM 9. The resulting determination is expressed as quasi-stationary dynamic SST. Solutions are obtained from different sets of long arcs in the GEOS-3 altimeter data bank as well as from sub-sets related to the September 1975 and March 1976 equinoxes assembled with a view to minimizing seasonal effects. The results are compared with equivalent parameters obtained from the hydrostatic analysis of sporadic temperature, pressure and salinity measurements of the oceans and the known major steady state current systems with comparable wavelengths. The most clearly defined parameter (the zonal harmonic of degree 2) is obtained with an uncertainty of + or - 6 cm. The preferred numerical value is smaller than the oceanographic value due to the effect of the correction for the permanent earth tide. Similar precision is achieved for the zonal harmonic of degree 3. The precision obtained for the fourth degree zonal harmonic reflects more closely the accuracy expected from the level of noise in the orbital solutions.
Peplies, J; Jiménez-Pavón, D; Savva, S C; Buck, C; Günther, K; Fraterman, A; Russo, P; Iacoviello, L; Veidebaum, T; Tornaritis, M; De Henauw, S; Mårild, S; Molnár, D; Moreno, L A; Ahrens, W
2014-09-01
The aim of this study is to present age- and sex-specific reference values of insulin, glucose, glycosylated haemoglobin (HbA1c) and the homeostasis model assessment to quantify insulin resistance (HOMA-IR) for pre-pubertal children. The reference population consists of 7074 normal weight 3- to 10.9-year-old pre-pubertal children from eight European countries who participated in at least one wave of the IDEFICS ('identification and prevention of dietary- and lifestyle-induced health effects in children and infants') surveys (2007-2010) and for whom standardised laboratory measurements were obtained. Percentile curves of insulin (measured by an electrochemiluminescence immunoassay), glucose, HbA1c and HOMA-IR were calculated as a function of age stratified by sex using the general additive model for location scale and shape (GAMLSS) method. Levels of insulin, fasting glucose and HOMA-IR continuously show an increasing trend with age, whereas HbA1c shows an upward trend only beyond the age of 8 years. Insulin and HOMA-IR values are higher in girls of all age groups, whereas glucose values are slightly higher in boys. Median serum levels of insulin range from 17.4 and 13.2 pmol l(-1) in 3-<3.5-year-old girls and boys, respectively, to 53.5 and 43.0 pmol l(-1) in 10.5-<11-year-old girls and boys. Median values of glucose are 4.3 and 4.5 mmol l(-1) in the youngest age group and 49.3 and 50.6 mmol l(-1) in the oldest girls and boys. For HOMA-IR, median values range from 0.5 and 0.4 in 3-<3.5-year-old girls and boys to 1.7 and 1.4 in 10.5-<11-year-old girls and boys, respectively. Our study provides the first standardised reference values for an international European children's population and provides the, up to now, largest data set of healthy pre-pubertal children to model reference percentiles for markers of insulin resistance. Our cohort shows higher values of Hb1Ac as compared with a single Swedish study while our percentiles for the other glucose metabolic markers are in good accordance with previous studies.
Mathematical Modelling of the Infusion Test
NASA Astrophysics Data System (ADS)
Cieslicki, Krzysztof
2007-01-01
The objective of this paper was to improve the well established in clinical practice Marmarou model for intracranial volume-pressure compensation by adding the pulsatile components. It was demonstrated that complicated pulsation and growth in intracranial pressure during infusion test could be successfully modeled by the relatively simple analytical expression derived in this paper. The CSF dynamics were tested in 25 patients with clinical symptoms of hydrocephalus. Basing on the frequency spectrum of the patient's baseline pressure and identified parameters of CSF dynamic, for each patient an "ideal" infusion test curve free from artefacts and slow waves was simulated. The degree of correlation between simulated and real curves obtained from clinical observations gave insight into the adequacy of assumptions of Marmarou model. The proposed method of infusion tests analysis designates more exactly the value of the reference pressure, which is usually treated as a secondary and of uncertain significance. The properly identified value of the reference pressure decides on the degree of pulsation amplitude growth during IT, as well as on the value of elastance coefficient. The artificially generated tests with various pulsation components were also applied to examine the correctness of the used algorithm of identification of the original Marmarou model parameters.
Simulation of aspheric tolerance with polynomial fitting
NASA Astrophysics Data System (ADS)
Li, Jing; Cen, Zhaofeng; Li, Xiaotong
2018-01-01
The shape of the aspheric lens changes caused by machining errors, resulting in a change in the optical transfer function, which affects the image quality. At present, there is no universally recognized tolerance criterion standard for aspheric surface. To study the influence of aspheric tolerances on the optical transfer function, the tolerances of polynomial fitting are allocated on the aspheric surface, and the imaging simulation is carried out by optical imaging software. Analysis is based on a set of aspheric imaging system. The error is generated in the range of a certain PV value, and expressed as a form of Zernike polynomial, which is added to the aspheric surface as a tolerance term. Through optical software analysis, the MTF of optical system can be obtained and used as the main evaluation index. Evaluate whether the effect of the added error on the MTF of the system meets the requirements of the current PV value. Change the PV value and repeat the operation until the acceptable maximum allowable PV value is obtained. According to the actual processing technology, consider the error of various shapes, such as M type, W type, random type error. The new method will provide a certain development for the actual free surface processing technology the reference value.
Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine
Jang, Megan; Guo, Tiedong; Soldin, Steven J.
2009-01-01
Background The clinical value of free thyroxine (FT4) and free triiodothyronine (FT3) analysis depends on the reference intervals with which they are compared. We determined age- and sex-specific reference intervals for neonates, infants, and children 0–18 years of age for FT4 and FT3 using tandem mass spectrometry. Methods Reference intervals were calculated for serum FT4 (n = 1426) and FT3 (n = 1107) obtained from healthy children between January 1, 2008, and June 30, 2008, from Children's National Medical Center and Georgetown University Medical Center Bioanalytical Core Laboratory, Washington, DC. Serum samples were analyzed using isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS) with deuterium-labeled internal standards. Results FT4 reference intervals were very similar for males and females of all ages and ranged between 1.3 and 2.4 ng/dL for children 1 to 18 years old. FT4 reference intervals for 1- to 12-month-old infants were 1.3–2.8 ng/dL. These 2.5 to 97.5 percentile intervals were much tighter than reference intervals obtained using immunoassay platforms 0.48–2.78 ng/dL for males and 0.85–2.09 ng/dL for females. Similarly, FT3 intervals were consistent and similar for males and females and for all ages, ranging between 1.5 pg/mL and approximately 6.0 pg/mL for children 1 month of age to 18 years old. Conclusions This is the first study to provide pediatric reference intervals of FT4 and FT3 for children from birth to 18 years of age using LC/MS/MS. Analysis using LC/MS/MS provides more specific quantification of thyroid hormones. A comparison of the ultrafiltration tandem mass spectrometric method with equilibrium dialysis showed very good correlation. PMID:19583487
Saura, Daniel; Dulgheru, Raluca; Caballero, Luis; Bernard, Anne; Kou, Seisyou; Gonjilashvili, Natalia; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; Van De Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Gori, Ann-Stephan; Cosyns, Bernard; Donal, Erwan; Habib, Gilbert; Addetia, Karima; Lang, Roberto M; Badano, Luigi P; Lancellotti, Patrizio
2017-02-01
To report normal reference ranges for echocardiographic dimensions of the proximal aorta obtained in a large group of healthy volunteers recruited using state-of-the-art cardiac ultrasound equipment, considering different measurement conventions, and taking into account gender, age, and body size of individuals. A total of 704 (mean age: 46.0 ± 13.5 years) healthy volunteers (310 men and 394 women) were prospectively recruited from the collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was obtained in all subjects following pre-defined protocols. Aortic dimensions were obtained in systole and diastole, following both the leading-edge to leading-edge and the inner-edge to inner-edge conventions. Diameters were measured at four levels: ventricular-arterial junction, sinuses of Valsalva, sino-tubular junction, and proximal tubular ascending aorta. Measures of aortic root in the short-axis view following the orientation of each of the three sinuses were also performed. Men had significantly larger body sizes when compared with women, and showed larger aortic dimensions independently of the measurement method used. Dimensions indexed by height and body surface area are provided, and stratification by age ranges is also displayed. In multivariable analysis, the independent predictors of aortic dimensions were age, gender, and height or body surface area. The NORRE study provides normal values of proximal aorta dimensions as assessed by echocardiography. Reference ranges for different anatomical levels using different (i) measurement conventions and (ii) at different times of the cardiac cycle (i.e. mid-systole and end-diastole) are provided. Age, gender, and body size were significant determinants of aortic dimensions. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Hayes, D.B.; Baylis, J.R.; Carl, L.M.; Dodd, H.R.; Goldstein, J.D.; McLaughlin, R.L.; Noakes, D.L.G.; Porto, L.M.
2003-01-01
Four sampling designs for quantifying the effect of low-head sea lamprey (Petromyzon marinus) barriers on fish communities were evaluated, and the contribution of process-oriented research to the overall confidence of results obtained was discussed. The designs include: (1) sample barrier streams post-construction; (2) sample barrier and reference streams post-construction; (3) sample barrier streams pre- and post-construction; and (4) sample barrier and reference streams pre- and post-construction. In the statistical literature, the principal basis for comparison of sampling designs is generally the precision achieved by each design. In addition to precision, designs should be compared based on the interpretability of results and on the scale to which the results apply. Using data collected in a broad survey of streams with and without sea lamprey barriers, some of the tradeoffs that occur among precision, scale, and interpretability are illustrated. Although circumstances such as funding and availability of pre-construction data may limit which design can be implemented, a pre/post-construction design including barrier and reference streams provides the most meaningful information for use in barrier management decisions. Where it is not feasible to obtain pre-construction data, a design including reference streams is important to maintain the interpretability of results. Regardless of the design used, process-oriented research provides a framework for interpreting results obtained in broad surveys. As such, information from both extensive surveys and intensive process-oriented research provides the best basis for fishery management actions, and gives researchers and managers the most confidence in the conclusions reached regarding the effects of sea lamprey barriers.
NASA Astrophysics Data System (ADS)
Perestoronin, A. V.
2017-03-01
An approach to the solution of the relativistic problem of the motion of a classical charged particle in the field of a monochromatic plane wave with an arbitrary polarization (linear, circular, or elliptic) is proposed. It is based on the analysis of the 4-vector equation of motion of the charged particle together with the 4-vector and tensor equations for the components of the electromagnetic field tensor of a monochromatic plane wave. This approach provides analytical expressions for the time-averaged square of the 4-acceleration of the charge, as well as for the averaged values of any quantities periodic in the time of the reference frame. Expressions for the integral power of scattered radiation, which is proportional to the time-averaged square of the 4-acceleration of the charge, and for the integral scattering cross section, which is the ratio of the power of scattered radiation to the intensity of incident radiation, are obtained for an arbitrary inertial reference frame. An expression for the scattering cross section, which coincides with the known results at the circular and linear polarizations of the incident waves and describes the case of elliptic polarization of the incident wave, is obtained for the reference frame where the charged particle is on average at rest. An expression for the scattering cross section including relativistic effects and the nonzero drift velocity of a particle in this system is obtained for the laboratory reference frame, where the initial velocity of the charged particle is zero. In the case of the circular polarization of the incident wave, the scattering cross section in the laboratory frame is equal to the Thompson cross section.
Muller, Edson I; Souza, Juliana P; Muller, Cristiano C; Muller, Aline L H; Mello, Paola A; Bizzi, Cezar A
2016-08-15
In this work a green digestion method which only used H2O2 as an oxidant and high temperature and pressure in the single reaction chamber system (SRC-UltraWave™) was applied for subsequent elemental determination by inductively coupled plasma-based techniques. Milk powder was chosen to demonstrate the feasibility and advantages of the proposed method. Samples masses up to 500mg were efficiently digested, and the determination of Ca, Fe, K, Mg and Na was performed by inductively coupled plasma optical emission spectrometry (ICP-OES), while trace elements (B, Ba, Cd, Cu, Mn, Mo, Pb, Sr and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Residual carbon (RC) lower than 918mgL(-1) of C was obtained for digests which contributed to minimizing interferences in determination by ICP-OES and ICP-MS. Accuracy was evaluated using certified reference materials NIST 1549 (non-fat milk powder certified reference material) and NIST 8435 (whole milk powder reference material). The results obtained by the proposed method were in agreement with the certified reference values (t-test, 95% confidence level). In addition, no significant difference was observed between results obtained by the proposed method and conventional wet digestion using concentrated HNO3. As digestion was performed without using any kind of acid, the characteristics of final digests were in agreement with green chemistry principles when compared to digests obtained using conventional wet digestion method with concentrated HNO3. Additionally, H2O2 digests were more suitable for subsequent analysis by ICP-based techniques due to of water being the main product of organic matrix oxidation. The proposed method was suitable for quality control of major components and trace elements present in milk powder in consonance with green sample preparation. Copyright © 2016 Elsevier B.V. All rights reserved.
Dinçer, Zafer; Basan, Hasan; Göger, Nilgün Günden
2003-04-01
A derivative UV spectrophotometric method for the determination of ambroxol in tablets was developed. Determination of ambroxol in tablets was conducted by using first-order derivative UV spectrophotometric method at 255 nm (n = 5). Standards for the calibration graph ranging from 5.0 to 35.0 microg/ml were prepared from stock solution. The proposed method was accurate with 98.6+/-0.4% recovery value and precise with coefficient of variation (CV) of 1.22. These results were compared with those obtained by reference methods, zero-order UV spectrophotometric method and reversed-phase high-performance liquid chromatography (HPLC) method. A reversed-phase C(18) column with aqueous phosphate (0.01 M)-acetonitrile-glacial acetic acid (59:40:1, v/v/v) (pH 3.12) mobile phase was used and UV detector was set to 252 nm. Calibration solutions used in HPLC were ranging from 5.0 to 20.0 microg/ml. Results obtained by derivative UV spectrophotometric method was comparable to those obtained by reference methods, zero-order UV spectrophotometric method and HPLC, as far as ANOVA test, F(calculated) = 0.762 and F(theoretical) = 3.89, was concerned. Copyright 2003 Elsevier Science B.V.
The International Standard for Oxytetracycline
Humphrey, J. H.; Lightbown, J. W.; Mussett, M. V.; Perry, W. L. M.
1955-01-01
The first attempt to set up an international standard for oxytetracycline, using oxytetracycline hydrochloride, failed because of difficulties in obtaining a preparation whose moisture content was uniform after distribution into ampoules. A preparation of dihydrate of oxytetracycline base was obtained instead, and was compared in an international collaborative assay with a sample of oxytetracycline hydrochloride, which was the current working standard of Chas. Pfizer & Co., Inc., USA. The results of the collaborative assay showed that the potency of the dihydrate was uniform, and that it was a suitable preparation for use as the International Standard. Evidence was obtained, however, that the reference preparation at the time of examination was less potent than had been originally supposed, and that it was hydrated. The potency of the proposed international standard was recalculated after allowance for water in the reference preparation, and the resulting biological potency agreed well with that to be expected on the basis of the physicochemical properties of the preparation. It was agreed, therefore, that the recalculated values should be used, and the preparation of oxytetracycline base dihydrate used in the collaborative assay is established as the International Standard for Oxytetracycline with a potency of 900 International Units per mg. PMID:13284563
No-reference multiscale blur detection tool for content based image retrieval
NASA Astrophysics Data System (ADS)
Ezekiel, Soundararajan; Stocker, Russell; Harrity, Kyle; Alford, Mark; Ferris, David; Blasch, Erik; Gorniak, Mark
2014-06-01
In recent years, digital cameras have been widely used for image capturing. These devices are equipped in cell phones, laptops, tablets, webcams, etc. Image quality is an important component of digital image analysis. To assess image quality for these mobile products, a standard image is required as a reference image. In this case, Root Mean Square Error and Peak Signal to Noise Ratio can be used to measure the quality of the images. However, these methods are not possible if there is no reference image. In our approach, a discrete-wavelet transformation is applied to the blurred image, which decomposes into the approximate image and three detail sub-images, namely horizontal, vertical, and diagonal images. We then focus on noise-measuring the detail images and blur-measuring the approximate image to assess the image quality. We then compute noise mean and noise ratio from the detail images, and blur mean and blur ratio from the approximate image. The Multi-scale Blur Detection (MBD) metric provides both an assessment of the noise and blur content. These values are weighted based on a linear regression against full-reference y values. From these statistics, we can compare to normal useful image statistics for image quality without needing a reference image. We then test the validity of our obtained weights by R2 analysis as well as using them to estimate image quality of an image with a known quality measure. The result shows that our method provides acceptable results for images containing low to mid noise levels and blur content.
Testosterone Trajectories and Reference Ranges in a Large Longitudinal Sample of Male Adolescents
Khairullah, Ammar; Cousino Klein, Laura; Ingle, Suzanne M.; May, Margaret T.; Whetzel, Courtney A.; Susman, Elizabeth J.; Paus, Tomáš
2014-01-01
Purpose Pubertal dynamics plays an important role in physical and psychological development of children and adolescents. We aim to provide reference ranges of plasma testosterone in a large longitudinal sample. Furthermore, we describe a measure of testosterone trajectories during adolescence that can be used in future investigations of development. Methods We carried out longitudinal measurements of plasma testosterone in 2,216 samples obtained from 513 males (9 to 17 years of age) from the Avon Longitudinal Study of Parents and Children. We used integration of a model fitted to each participant’s testosterone trajectory to calculate a measure of average exposure to testosterone over adolescence. We pooled these data with corresponding values reported in the literature to provide a reference range of testosterone levels in males between the ages of 6 and 19 years. Results The average values of total testosterone in the ALSPAC sample range from 0.82 nmol/L (Standard Deviation [SD]: 0.09) at 9 years of age to 16.5 (SD: 2.65) nmol/L at 17 years of age; these values are congruent with other reports in the literature. The average exposure to testosterone is associated with different features of testosterone trajectories such as Peak Testosterone Change, Age at Peak Testosterone Change, and Testosterone at 17 years of age as well as the timing of the growth spurt during puberty. Conclusions The average exposure to testosterone is a useful measure for future investigations using testosterone trajectories to examine pubertal dynamics. PMID:25268961
Rérolle, Camille; Saint-Martin, Pauline; Dedouit, Fabrice; Rousseau, Hervé; Telmon, Norbert
2013-09-10
The first step in the identification process of bone remains is to determine whether they are of human or nonhuman origin. This issue may arise when only a fragment of bone is available, as the species of origin is usually easily determined on a complete bone. The present study aims to assess the validity of a morphometric method used by French forensic anthropologists to determine the species of origin: the corticomedullary index (CMI), defined by the ratio of the diameter of the medullary cavity to the total diameter of the bone. We studied the constancy of the CMI from measurements made on computed tomography images (CT scans) of different human bones, and compared our measurements with reference values selected in the literature. The measurements obtained on CT scans at three different sites of 30 human femurs, 24 tibias, and 24 fibulas were compared between themselves and with the CMI reference values for humans, pigs, dogs and sheep. Our results differed significantly from these reference values, with three exceptions: the proximal quarter of the femur and mid-fibular measurements for the human CMI, and the proximal quarter of the tibia for the sheep CMI. Mid-tibial, mid-femoral, and mid-fibular measurements also differed significantly between themselves. Only 22.6% of CT scans of human bones were correctly identified as human. We concluded that the CMI is not an effective method for determining the human origin of bone remains. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Buchholz, Hannes; Emel'yanenko, Vladimir N; Lorenz, Heike; Verevkin, Sergey P
2016-05-01
A detailed experimental analysis of the phase transition thermodynamics of (S)-naproxen and (RS)-naproxen is reported. Vapor pressures were determined experimentally via the transpiration method. Sublimation enthalpies were obtained from the vapor pressures and from independent TGA measurements. Thermodynamics of fusion which have been well-studied in the literature were systematically remeasured by DSC. Both sublimation and fusion enthalpies were adjusted to one reference temperature, T = 298 K, using measured heat capacities of the solid and the melt phase by DSC. Average values from the measurements and from literature data were suggested for the sublimation and fusion enthalpies. In order to prove consistency of the proposed values the vaporization enthalpies obtained by combination of both were compared to vaporization enthalpies obtained by the group-additivity method and the correlation-gas chromatography method. The importance of reliable and precise phase transition data for thermochemical calculations such as the prediction of solid/liquid phase behaviour of chiral compounds is highlighted. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Schrangl, Patrick; Reiterer, Florian; Heinemann, Lutz; Freckmann, Guido; Del Re, Luigi
2018-05-18
Systems for continuous glucose monitoring (CGM) are evolving quickly, and the data obtained are expected to become the basis for clinical decisions for many patients with diabetes in the near future. However, this requires that their analytical accuracy is sufficient. This accuracy is usually determined with clinical studies by comparing the data obtained by the given CGM system with blood glucose (BG) point measurements made with a so-called reference method. The latter is assumed to indicate the correct value of the target quantity. Unfortunately, due to the nature of the clinical trials and the approach used, such a comparison is subject to several effects which may lead to misleading results. While some reasons for the differences between the values obtained with CGM and BG point measurements are relatively well-known (e.g., measurement in different body compartments), others related to the clinical study protocols are less visible, but also quite important. In this review, we present a general picture of the topic as well as tools which allow to correct or at least to estimate the uncertainty of measures of CGM system performance.
NASA Astrophysics Data System (ADS)
Rasuli, Behrouz; Tabari Juybari, Raheleh; Forouzi, Meysam; Ghorbani, Mohammad
2017-09-01
Introduction: The main purpose of this study was to investigate patient dose in pelvic and abdomen x-ray examinations. This work also provided the LDRLs (local diagnostic reference levels) in Khuzestan region, southwest of Iran to help establish the NDRLs (national diagnostic reference levels). Methods: Patient doses were assessed from patient's anatomical data and exposure parameters based on the IAEA indirect dosimetry method. With regard to this method, exposure parameters such as tube output, kVp, mAs, FFD and patient anatomical data were used for calculating ESD (entrance skin dose) of patients. This study was conducted on 250 standard patients (50% men and 50% women) at eight high-patient-load imaging centers. Results: The results indicate that mean ESDs for the both pelvic and abdomen examinations were lower than the IAEA and EC reference levels, 2.3 and 3.7 mGy, respectively. Mean applied kVps were 67 and 70 and mean FFDs were 103 and 109, respectively. Tube loadings obtained in this study for pelvic examination were lower than all the corresponding values in the reviewed literature. Likewise, the average annual patient load across all hospitals were more than 37000 patients, i.e. more than 100 patients a day. Conclusions: The authors recommend that DRLs (diagnostic reference levels) obtained in this region, which are the first available data, can be used as local DRLs for pelvic and abdomen procedures. This work also provides that on-the-job training programs for staffs and close cross collaboration between physicists and physicians should be strongly considered.
Deriving proper measurement uncertainty from Internal Quality Control data: An impossible mission?
Ceriotti, Ferruccio
2018-03-30
Measurement uncertainty (MU) is a "non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used". In the clinical laboratory the most convenient way to calculate MU is the "top down" approach based on the use of Internal Quality Control data. As indicated in the definition, MU depends on the information used for its calculation and so different estimates of MU can be obtained. The most problematic aspect is how to deal with bias. In fact bias is difficult to detect and quantify and it should be corrected including only the uncertainty derived from this correction. Several approaches to calculate MU starting from Internal Quality Control data are presented. The minimum requirement is to use only the intermediate precision data, provided to include 6 months of results obtained with a commutable quality control material at a concentration close to the clinical decision limit. This approach is the minimal requirement and it is convenient for all those measurands that are especially used for monitoring or where a reference measurement system does not exist and so a reference for calculating the bias is lacking. Other formulas including the uncertainty of the value of the calibrator, including the bias from a commutable certified reference material or from a material specifically prepared for trueness verification, including the bias derived from External Quality Assessment schemes or from historical mean of the laboratory are presented and commented. MU is an important parameter, but a single, agreed upon way to calculate it in a clinical laboratory is not yet available. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
Characterization of plasma parameters in shaped PBX-M discharges
NASA Astrophysics Data System (ADS)
England, A. C.; Bell, R. E.; Hirshman, S. P.; Kaita, R.; Kugel, H. W.; LeBlanc, B. L.; Lee, D. K.; Okabayashi, M.; Sun, Y.-C.; Takahashi, H.
1997-09-01
The Princeton Beta Experiment-Modification (PBX-M) was run both with elliptical and with bean-shaped plasmas during the 1992 and 1993 operating periods. Two deuterium-fed neutral beams were used for auxiliary heating, and during 1992 the average power was 0741-3335/39/9/008/img13. This will be referred to as the lower neutral-beam power (LNBP) period. As many as four deuterium-fed neutral beams were used during 1993, and the average power was 0741-3335/39/9/008/img14. This will be referred to as the medium neutral-beam power (MNBP) period. The neutron source strength, Sn, showed a scaling with injected power 0741-3335/39/9/008/img15, 0741-3335/39/9/008/img16 for both the LMBP and MNBP periods. A much wider range of shaping parameters was studied during the MNBP as compared with the LNBP period. A weak positive dependence on bean shaping was observed for the LNBP, and a stronger positive dependence on shaping was observed for MNBP, viz 0741-3335/39/9/008/img17. High values of Sn were obtained in bean-shaped plasmas for the highest values of 0741-3335/39/9/008/img18 at 0741-3335/39/9/008/img19 for the LNBP. For the MNBP the highest values of Sn and stored energy were obtained at 0741-3335/39/9/008/img19, and the highest values of 0741-3335/39/9/008/img18 were obtained at 0741-3335/39/9/008/img22. The achievement of high Sn is aided by high neutral-beam power, high toroidal field, strong shaping, high electron temperature, and broad profiles. The achievement of high 0741-3335/39/9/008/img18 is aided by low toroidal field, high density, less shaping, broad profiles, and access to the H-mode, viz 0741-3335/39/9/008/img24. The achievement of high 0741-3335/39/9/008/img25 is aided by strong shaping, high density, broad profiles, and access to the H-mode, viz 0741-3335/39/9/008/img26. Some comparisons with the previous higher neutral-beam (HNBP) period in 1989 are also made.
Evaluation of RayXpert® for shielding design of medical facilities
NASA Astrophysics Data System (ADS)
Derreumaux, Sylvie; Vecchiola, Sophie; Geoffray, Thomas; Etard, Cécile
2017-09-01
In a context of growing demands for expert evaluation concerning medical, industrial and research facilities, the French Institute for radiation protection and nuclear safety (IRSN) considered necessary to acquire new software for efficient dimensioning calculations. The selected software is RayXpert®. Before using this software in routine, exposure and transmission calculations for some basic configurations were validated. The validation was performed by the calculation of gamma dose constants and tenth value layers (TVL) for usual shielding materials and for radioisotopes most used in therapy (Ir-192, Co-60 and I-131). Calculated values were compared with results obtained using MCNPX as a reference code and with published values. The impact of different calculation parameters, such as the source emission rays considered for calculation and the use of biasing techniques, was evaluated.
An AK-LDMeans algorithm based on image clustering
NASA Astrophysics Data System (ADS)
Chen, Huimin; Li, Xingwei; Zhang, Yongbin; Chen, Nan
2018-03-01
Clustering is an effective analytical technique for handling unmarked data for value mining. Its ultimate goal is to mark unclassified data quickly and correctly. We use the roadmap for the current image processing as the experimental background. In this paper, we propose an AK-LDMeans algorithm to automatically lock the K value by designing the Kcost fold line, and then use the long-distance high-density method to select the clustering centers to further replace the traditional initial clustering center selection method, which further improves the efficiency and accuracy of the traditional K-Means Algorithm. And the experimental results are compared with the current clustering algorithm and the results are obtained. The algorithm can provide effective reference value in the fields of image processing, machine vision and data mining.
Paraskevas, Paschalis D; Sabbe, Maarten K; Reyniers, Marie-Françoise; Papayannakos, Nikos; Marin, Guy B
2014-06-23
Hydrogen abstractions are important elementary reactions in a variety of reacting media at high temperatures in which oxygenates and hydrocarbon radicals are present. Accurate kinetic data are obtained from CBS-QB3 ab initio (AI) calculations by using conventional transition-state theory within the high-pressure limit, including corrections for hindered rotation and tunneling. From the obtained results, a group-additive (GA) model is developed that allows the Arrhenius parameters and rate coefficients for abstraction of the α-hydrogen from a wide range of oxygenate compounds to be predicted at temperatures ranging from 300 to 1500 K. From a training set of 60 hydrogen abstractions from oxygenates by carbon-centered radicals, 15 GA values (ΔGAV°s) are obtained for both the forward and reverse reactions. Among them, four ΔGAV°s refer to primary contributions, and the remaining 11 ΔGAV°s refer to secondary ones. The accuracy of the model is further improved by introducing seven corrections for cross-resonance stabilization of the transition state from an additional set of 43 reactions. The determined ΔGAV°s are validated upon a test set of AI data for 17 reactions. The mean absolute deviation of the pre-exponential factors (log A) and activation energies (E(a)) for the forward reaction at 300 K are 0.238 log(m(3) mol(-1) s(-1)) and 1.5 kJ mol(-1), respectively, whereas the mean factor of deviation <ρ> between the GA-predicted and the AI-calculated rate coefficients is 1.6. In comparison with a compilation of 33 experimental rate coefficients, the <ρ> between the GA-predicted values and these experimental values is only 2.2. Hence, the constructed GA model can be reliably used in the prediction of the kinetics of α-hydrogen-abstraction reactions between a broad range of oxygenates and oxygenate radicals. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
2014-01-01
Background The possibility of applying a novel chemometric approach which could allow the differentiation of marble samples, all from different quarries located in the Mediterranean basin and frequently used in ancient times for artistic purposes, was investigated. By suggesting tentative or allowing to rule out unlikely attributions, this kind of differentiation could, indeed, be of valuable support to restorers and other professionals in the field of cultural heritage. Experimental data were obtained only using thermal analytical techniques: Thermogravimetry (TG), Derivative Thermogravimetry (DTG) and Differential Thermal Analysis (DTA). Results The extraction of kinetic parameters from the curves obtained using these thermal analytical techniques allowed Activation Energy values to be evaluated together with the logarithm of the Arrhenius pre-exponential factor of the main TG-DTG process. The main data thus obtained after subsequent chemometric evaluation (using Principal Components Analysis) have already proved useful in the identification the original quarry of a small number of archaeological marble finds. Conclusion One of the most evident advantages of the thermoanalytical – chemometric approach adopted seems to be that it allows the certain identification of an unknown find composed of a marble known to be present among the reference samples considered, that is, contained in the reference file. On the other hand with equal certainty it prevents the occurrence of erroneous or highly uncertain identification if the find being tested does not belong to the reference file considered. PMID:24982691
García-Jaramillo, Maira; Calm, Remei; Bondia, Jorge; Tarín, Cristina; Vehí, Josep
2009-01-01
Objective The objective of this article was to develop a methodology to quantify the risk of suffering different grades of hypo- and hyperglycemia episodes in the postprandial state. Methods Interval predictions of patient postprandial glucose were performed during a 5-hour period after a meal for a set of 3315 scenarios. Uncertainty in the patient's insulin sensitivities and carbohydrate (CHO) contents of the planned meal was considered. A normalized area under the curve of the worst-case predicted glucose excursion for severe and mild hypo- and hyperglycemia glucose ranges was obtained and weighted accordingly to their importance. As a result, a comprehensive risk measure was obtained. A reference model of preprandial glucose values representing the behavior in different ranges was chosen by a ξ2 test. The relationship between the computed risk index and the probability of occurrence of events was analyzed for these reference models through 19,500 Monte Carlo simulations. Results The obtained reference models for each preprandial glucose range were 100, 160, and 220 mg/dl. A relationship between the risk index ranges <10, 10–60, 60–120, and >120 and the probability of occurrence of mild and severe postprandial hyper- and hypoglycemia can be derived. Conclusions When intrapatient variability and uncertainty in the CHO content of the meal are considered, a safer prediction of possible hyper- and hypoglycemia episodes induced by the tested insulin therapy can be calculated. PMID:20144339
Tracer Kinetic Analysis of (S)-¹⁸F-THK5117 as a PET Tracer for Assessing Tau Pathology.
Jonasson, My; Wall, Anders; Chiotis, Konstantinos; Saint-Aubert, Laure; Wilking, Helena; Sprycha, Margareta; Borg, Beatrice; Thibblin, Alf; Eriksson, Jonas; Sörensen, Jens; Antoni, Gunnar; Nordberg, Agneta; Lubberink, Mark
2016-04-01
Because a correlation between tau pathology and the clinical symptoms of Alzheimer disease (AD) has been hypothesized, there is increasing interest in developing PET tracers that bind specifically to tau protein. The aim of this study was to evaluate tracer kinetic models for quantitative analysis and generation of parametric images for the novel tau ligand (S)-(18)F-THK5117. Nine subjects (5 with AD, 4 with mild cognitive impairment) received a 90-min dynamic (S)-(18)F-THK5117 PET scan. Arterial blood was sampled for measurement of blood radioactivity and metabolite analysis. Volume-of-interest (VOI)-based analysis was performed using plasma-input models; single-tissue and 2-tissue (2TCM) compartment models and plasma-input Logan and reference tissue models; and simplified reference tissue model (SRTM), reference Logan, and SUV ratio (SUVr). Cerebellum gray matter was used as the reference region. Voxel-level analysis was performed using basis function implementations of SRTM, reference Logan, and SUVr. Regionally averaged voxel values were compared with VOI-based values from the optimal reference tissue model, and simulations were made to assess accuracy and precision. In addition to 90 min, initial 40- and 60-min data were analyzed. Plasma-input Logan distribution volume ratio (DVR)-1 values agreed well with 2TCM DVR-1 values (R(2)= 0.99, slope = 0.96). SRTM binding potential (BP(ND)) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 (R(2)= 1.00, slope ≈ 1.00) whereas SUVr(70-90)-1 values correlated less well and overestimated binding. Agreement between parametric methods and SRTM was best for reference Logan (R(2)= 0.99, slope = 1.03). SUVr(70-90)-1 values were almost 3 times higher than BP(ND) values in white matter and 1.5 times higher in gray matter. Simulations showed poorer accuracy and precision for SUVr(70-90)-1 values than for the other reference methods. SRTM BP(ND) and reference Logan DVR-1 values were not affected by a shorter scan duration of 60 min. SRTM BP(ND) and reference Logan DVR-1 values were highly correlated with plasma-input Logan DVR-1 values. VOI-based data analyses indicated robust results for scan durations of 60 min. Reference Logan generated quantitative (S)-(18)F-THK5117 DVR-1 parametric images with the greatest accuracy and precision and with a much lower white-matter signal than seen with SUVr(70-90)-1 images. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Noto, Nobutaka; Kato, Masataka; Abe, Yuriko; Kamiyama, Hiroshi; Karasawa, Kensuke; Ayusawa, Mamoru; Takahashi, Shori
2015-01-01
Previous studies that used carotid ultrasound have been largely conflicting in regards to whether or not patients after Kawasaki disease (KD) have a greater carotid intima-media thickness (CIMT) than controls. To test the hypothesis that there are significant differences between the values of CIMT expressed as absolute values and standard deviation scores (SDS) in children and adolescents after KD and controls, we reviewed 12 published articles regarding CIMT on KD patients and controls. The mean ± SD of absolute CIMT (mm) in the KD patients and controls obtained from each article was transformed to SDS (CIMT-SDS) using age-specific reference values established by Jourdan et al. (J: n = 247) and our own data (N: n = 175), and the results among these 12 articles were compared between the two groups and the references for comparison of racial disparities. There were no significant differences in mean absolute CIMT and mean CIMT-SDS for J between KD patients and controls (0.46 ± 0.06 mm vs. 0.44 ± 0.04 mm, p = 0.133, and 1.80 ± 0.84 vs. 1.25 ± 0.12, p = 0.159, respectively). However, there were significant differences in mean CIMT-SDS for N between KD patients and controls (0.60 ± 0.71 vs. 0.01 ± 0.65, p = 0.042). When we assessed the nine articles on Asian subjects, the difference of CIMT-SDS between the two groups was invariably significant only for N (p = 0.015). Compared with the reference values, CIMT-SDS of controls was within the normal range at a rate of 41.6 % for J and 91.6 % for N. These results indicate that age- and race-specific reference values for CIMT are mandatory for performing accurate assessment of the vascular status in healthy children and adolescents, particularly in those after KD considered at increased long-term cardiovascular risk.
Double Star Measurements at the Northern Sky with a 10 inch Newtonian in 2014 and 2015
NASA Astrophysics Data System (ADS)
Anton, Rainer
2017-07-01
A 10 inch Newtonian was used for recordings of double stars with a CCD webcam, and measurements of 120 pairs were done with the technique of “lucky imaging”. A rather accurate value of the image scale was obtained with reference systems from the recently published Gaia catalogue of very precise position data. For several pairs, deviations from currently assumed orbits were found. Some images of noteworthy systems are also presented.
GFAAS determination of selenium in infant formulas using a microwave digestion method.
Alegria, A; Barbera, R; Farré, R; Moreno, A
1994-01-01
A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.
Assessment of Mycosphaerella graminicola resistance to azoxystrobin.
Siah, A; Deweer, C; Morand, E; Reignault, Ph; Halama, P
2008-01-01
Azoxystrobin resistance levels of twenty two strains sampled from ten French locations and two reference isolates (IPO323 and IPO94269) of the wheat pathogen Mycosphaerella graminicola were investigated in vitro. French strains assayed were selected from twenty two genetic groups determined from three hundred sixty three strains previously characterised using microsatellites, actine and beta-tubuline markers. For the first time, the evaluation was carried out using four distinct methods: spotting on PDA medium, spore germination on PDA medium and using microtitre plates with and without Alamar blue, a growth indicator. From dose-response curve, half maximal inhibitory concentration (IC50) was determined for each strain. The results obtained using microtitre plates with the addition of Alamar blue displayed high standard deviations from the growth averages observed. Therefore, we suggest that this method is inadequate to assess M. graminicolo resistance to fungicides. However, a good correlation was observed between the rankings of strains according to their IC50 values with the three other methods used. The two reference isolates, as expected, were inhibited by low azoxystrobin concentrations. On the other hand, the IC50 values obtained showed presence of a threshold between sensitive and resistant strains that corroborates the disruptive resistance of M. graminicola against strobilurin fungicides. In addition, the strains showing resistance were those sampled mainly from northern France, where a high frequency of strobilurin resistant isolates among M. graminicola populations was reported by several studies.
USDA-ARS?s Scientific Manuscript database
Workshops sponsored by the Institute of Medicine (IOM) and the World Health Organization (WHO) suggested that incorporating systematic reviews into the process of updating nutrient reference values would enhance the transparency of the process. The IOM issues the Dietary Reference Intake values (DR...
NASA Astrophysics Data System (ADS)
Rodrigo, F. S.; Gómez-Navarro, J. J.; Montávez Gómez, J. P.
2011-07-01
In this work, a reconstruction of climatic conditions in Andalusia (southern Iberia Peninsula) during the period 1701-1850, as well as an evaluation of its associated uncertainties, is presented. This period is interesting because it is characterized by a minimum in the solar irradiance (Dalton Minimum, around 1800), as well as intense volcanic activity (for instance, the eruption of the Tambora in 1815), when the increasing atmospheric CO2 concentrations were of minor importance. The reconstruction is based on the analysis of a wide variety of documentary data. The reconstruction methodology is based on accounting the number of extreme events in past, and inferring mean value and standard deviation using the assumption of normal distribution for the seasonal means of climate variables. This reconstruction methodology is tested within the pseudoreality of a high-resolution paleoclimate simulation performed with the regional climate model MM5 coupled to the global model ECHO-G. Results show that the reconstructions are influenced by the reference period chosen and the threshold values used to define extreme values. This creates uncertainties which are assesed within the context of the climate simulation. An ensemble of reconstructions was obtained using two different reference periods and two pairs of percentiles as threshold values. Results correspond to winter temperature, and winter, spring, and autumn rainfall, and they are compared with simulations of the climate model for the considered period. The comparison of the distribution functions corresponding to 1790-1820 and 1960-1990 periods indicates that during the Dalton Minimum the frequency of dry and warm (wet and cold) winters was lesser (higher) than during the reference period. In spring and autumn it was detected an increase (decrease) in the frequency of wet (dry) seasons. Future research challenges are outlined.
Haderslev, Kent Valentin; Jeppesen, Paller Bekker; Sorensen, Henrik Ancher; Mortensen, Per Brobech; Staun, Michael
2003-07-01
Patients who have undergone resection of the small intestine have lower body weight than do healthy persons. It remains unclear whether it is the body fat mass or the lean tissue mass that is reduced. We compared body-composition values in patients who had undergone small-intestinal resection with reference values obtained in healthy volunteers, and we studied the relation between body-composition estimates and the net intestinal absorption of energy. In a cross-sectional study, we included 20 men and 24 women who had undergone small-intestinal resection and had malabsorption of energy > 2000 kJ/d. Diagnoses were Crohn disease (n = 37) and other conditions (n = 7). Body composition was estimated by dual-energy X-ray absorptiometry, and data were compared with those from a reference group of 173 healthy volunteers. Energy absorption was measured during 48-h balance studies by using bomb calorimetry, and individual values were expressed relative to the basal metabolic rate. Body weight and body mass index in patients were significantly (P < 0.05) lower than the reference values. Fat mass was 6.4 kg (30%) lower (95% CI: -8.8, -3.9 kg), but lean tissue mass was only slightly and insignificantly lower (1.5 kg, or 3.3%; 95% CI: -3.7, 0.60 kg). Weight, body mass index, and body-composition estimates by dual-energy X-ray absorptiometry did not correlate significantly with the net energy absorption relative to the basal metabolic rate, expressed as a percentage. Patients who had undergone small-intestinal resection had significantly lower body weights and body mass indexes than did healthy persons, and they had significant changes in body composition, mainly decreased body fat mass.
Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul
2018-01-15
The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.
Zhu, Yanbei; Inagaki, Kazumi; Yarita, Takashi; Chiba, Koichi
2008-07-01
Microwave digestion and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-SFMS) has been applied to the determination of Pb in rice flour. In order to achieve highly precise determination of low concentrations of Pb, the digestion blank for Pb was reduced to 0.21 ng g(-1) after optimization of the digestion conditions, in which 20 mL analysis solution was obtained after digestion of 0.5 g rice flour. The observed value of Pb in a non-fat milk powder certified reference material (CRM), NIST SRM 1549, was 16.8 +/- 0.8 ng g(-1) (mean +/- expanded uncertainty, k = 2; n = 5), which agreed with the certified value of 19 +/- 3 ng g(-1) and indicated the effectiveness of the method. Analytical results for Pb in three brown rice flour CRMs, NIST SRM 1568a, NIES CRM 10-a, and NIES CRM 10-b, were 7.32 +/- 0.24 ng g(-1) (n = 5), 1010 +/- 10 ng g(-1) (n = 5), and 1250 +/- 20 ng g(-1) (n = 5), respectively. The concentration of Pb in a candidate white rice flour reference material (RM) sample prepared by the National Metrology Institute of Japan (NMIJ) was observed to be 4.36 +/- 0.28 ng g(-1) (n = 10 bottles).
Multi-viewpoint Image Array Virtual Viewpoint Rapid Generation Algorithm Based on Image Layering
NASA Astrophysics Data System (ADS)
Jiang, Lu; Piao, Yan
2018-04-01
The use of multi-view image array combined with virtual viewpoint generation technology to record 3D scene information in large scenes has become one of the key technologies for the development of integrated imaging. This paper presents a virtual viewpoint rendering method based on image layering algorithm. Firstly, the depth information of reference viewpoint image is quickly obtained. During this process, SAD is chosen as the similarity measure function. Then layer the reference image and calculate the parallax based on the depth information. Through the relative distance between the virtual viewpoint and the reference viewpoint, the image layers are weighted and panned. Finally the virtual viewpoint image is rendered layer by layer according to the distance between the image layers and the viewer. This method avoids the disadvantages of the algorithm DIBR, such as high-precision requirements of depth map and complex mapping operations. Experiments show that, this algorithm can achieve the synthesis of virtual viewpoints in any position within 2×2 viewpoints range, and the rendering speed is also very impressive. The average result proved that this method can get satisfactory image quality. The average SSIM value of the results relative to real viewpoint images can reaches 0.9525, the PSNR value can reaches 38.353 and the image histogram similarity can reaches 93.77%.
TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...
A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of the Abraxis LLC Coplanar PCB Enzyme-Linked Immunosorbent Assay (ELISA) kit. The kit is an immunoassay technique that reports the total toxicity equivalents (TEQ) of polychlorinated biphenyls (PCBs). The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Method 1668A.Abraxis generally reported data that were higher than the reference laboratory TEQPCB values, with the exception of ultra-high level PCB samples [> 10,000 picogram/gram (pg/g) TEQ] where Abraxis reported values lower than the reference method. The technologys estimated MDL was 6 to 31 pg/g TEQPCB. Results from this demonstration suggest that the Abraxis kit could be an effective screening tool for screening sample concentrations above and below 50 pg/g TEQPCB, particularly considering that the cost ($22,668 vs. $184,449) and the time to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
An Evaluation of the Pea Pod System for Assessing Body Composition of Moderately Premature Infants.
Forsum, Elisabet; Olhager, Elisabeth; Törnqvist, Caroline
2016-04-22
(1) BACKGROUND: Assessing the quality of growth in premature infants is important in order to be able to provide them with optimal nutrition. The Pea Pod device, based on air displacement plethysmography, is able to assess body composition of infants. However, this method has not been sufficiently evaluated in premature infants; (2) METHODS: In 14 infants in an age range of 3-7 days, born after 32-35 completed weeks of gestation, body weight, body volume, fat-free mass density (predicted by the Pea Pod software), and total body water (isotope dilution) were assessed. Reference estimates of fat-free mass density and body composition were obtained using a three-component model; (3) RESULTS: Fat-free mass density values, predicted using Pea Pod, were biased but not significantly (p > 0.05) different from reference estimates. Body fat (%), assessed using Pea Pod, was not significantly different from reference estimates. The biological variability of fat-free mass density was 0.55% of the average value (1.0627 g/mL); (4) CONCLUSION: The results indicate that the Pea Pod system is accurate for groups of newborn, moderately premature infants. However, more studies where this system is used for premature infants are needed, and we provide suggestions regarding how to develop this area.
NASA Astrophysics Data System (ADS)
Apel, W. D.; Arteaga-Velázquez, J. C.; Bähren, L.; Bekk, K.; Bertaina, M.; Biermann, P. L.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Cantoni, E.; Chiavassa, A.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Falcke, H.; Fuchs, B.; Gemmeke, H.; Grupen, C.; Haungs, A.; Heck, D.; Hiller, R.; Hörandel, J. R.; Horneffer, A.; Huber, D.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Krömer, O.; Kuijpers, J.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Melissas, M.; Morello, C.; Nehls, S.; Oehlschläger, J.; Palmieri, N.; Pierog, T.; Rautenberg, J.; Rebel, H.; Roth, M.; Rühle, C.; Saftoiu, A.; Schieler, H.; Schmidt, A.; Schoo, S.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Weindl, A.; Wochele, J.; Zabierowski, J.; Zensus, J. A.
2016-02-01
LOPES was a digital antenna array detecting the radio emission of cosmic-ray air showers. The calibration of the absolute amplitude scale of the measurements was done using an external, commercial reference source, which emits a frequency comb with defined amplitudes. Recently, we obtained improved reference values by the manufacturer of the reference source, which significantly changed the absolute calibration of LOPES. We reanalyzed previously published LOPES measurements, studying the impact of the changed calibration. The main effect is an overall decrease of the LOPES amplitude scale by a factor of 2.6 ± 0.2, affecting all previously published values for measurements of the electric-field strength. This results in a major change in the conclusion of the paper 'Comparing LOPES measurements of air-shower radio emission with REAS 3.11 and CoREAS simulations' published by Apel et al. (2013) : With the revised calibration, LOPES measurements now are compatible with CoREAS simulations, but in tension with REAS 3.11 simulations. Since CoREAS is the latest version of the simulation code incorporating the current state of knowledge on the radio emission of air showers, this new result indicates that the absolute amplitude prediction of current simulations now is in agreement with experimental data.
Clinical management of chronic obstructive pulmonary disease patients with muscle dysfunction
Casadevall, Carme; Pascual, Sergi; Orozco-Levi, Mauricio; Barreiro, Esther
2016-01-01
Muscle dysfunction is frequently observed in chronic obstructive pulmonary disease (COPD) patients, contributing to their exercise limitation and a worsening prognosis. The main factor leading to limb muscle dysfunction is deconditioning, whereas respiratory muscle dysfunction is mostly the result of pulmonary hyperinflation. However, both limb and respiratory muscles are also influenced by other negative factors, including smoking, systemic inflammation, nutritional abnormalities, exacerbations and some drugs. Limb muscle weakness is generally diagnosed through voluntary isometric maneuvers such as handgrip or quadriceps muscle contraction (dynamometry); while respiratory muscle loss of strength is usually recognized through a decrease in maximal static pressures measured at the mouth. Both types of measurements have validated reference values. Respiratory muscle strength can also be evaluated determining esophageal, gastric and transdiaphragmatic maximal pressures although there is a lack of widely accepted reference equations. Non-volitional maneuvers, obtained through electrical or magnetic stimulation, can be employed in patients unable to cooperate. Muscle endurance can also be assessed, generally using repeated submaximal maneuvers until exhaustion, but no validated reference values are available yet. The treatment of muscle dysfunction is multidimensional and includes improvement in lifestyle habits (smoking abstinence, healthy diet and a good level of physical activity, preferably outside), nutritional measures (diet supplements and occasionally, anabolic drugs), and different modalities of general and muscle training. PMID:28066619
Demeke, Tigst; Eng, Monika
2018-05-01
Droplet digital PCR (ddPCR) has been used for absolute quantification of genetically engineered (GE) events. Absolute quantification of GE events by duplex ddPCR requires the use of appropriate primers and probes for target and reference gene sequences in order to accurately determine the amount of GE materials. Single copy reference genes are generally preferred for absolute quantification of GE events by ddPCR. Study has not been conducted on a comparison of reference genes for absolute quantification of GE canola events by ddPCR. The suitability of four endogenous reference sequences ( HMG-I/Y , FatA(A), CruA and Ccf) for absolute quantification of GE canola events by ddPCR was investigated. The effect of DNA extraction methods and DNA quality on the assessment of reference gene copy numbers was also investigated. ddPCR results were affected by the use of single vs. two copy reference genes. The single copy, FatA(A), reference gene was found to be stable and suitable for absolute quantification of GE canola events by ddPCR. For the copy numbers measured, the HMG-I/Y reference gene was less consistent than FatA(A) reference gene. The expected ddPCR values were underestimated when CruA and Ccf (two copy endogenous Cruciferin sequences) were used because of high number of copies. It is important to make an adjustment if two copy reference genes are used for ddPCR in order to obtain accurate results. On the other hand, real-time quantitative PCR results were not affected by the use of single vs. two copy reference genes.
How Much Nutrition for How Much Growth? .
Hermanussen, Michael; Wit, Jan M
2017-01-01
Increasing agreement exists about the use of length-for-age as the indicator of choice in monitoring the long-term impact of chronic nutritional deficiency. Yet, already shortly after World War I, a causal link between nutrition and growth was questioned. Also, modern meta-analyses of controlled nutrition intervention studies show that the net effect of nutrition on body height is small. Broad evidence obtained from historic observations on human starvation made since the 19th century questions an obligatory association between nutrition and growth. Many additional explanations for the apparent shortness of people from developing countries have been published since, focusing on genetic factors, environment, economy, epigenetics, and, recently, psychosocial factors, such as strategic growth adjustments suggesting stature to be a social signal. The marked variability in average population height of up to 20 cm within a few generations complicates the use of normative growth charts, even though they have been widely propagated. We support the concept of local growth references, for example using the "Synthetic Growth References" methodology. These references combine local growth information obtained from a given population of interest and common features of human population growth, with LMS values for height, weight, and BMI from birth to maturity. . © 2016 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Zayed, M. A.; El-Rasheedy, El-Gazy A.
2012-03-01
Two simple, sensitive, cheep and reliable spectrophotometric methods are suggested for micro-determination of pseudoephedrine in its pure form and in pharmaceutical preparation (Sinofree Tablets). The first one depends on the drug reaction with inorganic sensitive reagent like molybdate anion in aqueous media via formation of ion-pair mechanism. The second one depends on the drug reaction with π-acceptor reagent like DDQ in non-aqueous media via formation of charge transfer complex. These reactions were studied under various conditions and the optimum parameters were selected. Under proper conditions the suggested procedures were successfully applied for micro-determination of pseudoephedrine in pure and in Sinofree Tablets without interference from excepients. The values of SD, RSD, recovery %, LOD, LOQ and Sandell sensitivity refer to the high accuracy and precession of the applied procedures. The results obtained were compared with the data obtained by an official method, referring to confidence and agreement with DDQ procedure results; but it referred to the more accuracy of the molybdate data. Therefore, the suggested procedures are now successfully being applied in routine analysis of this drug in its pharmaceutical formulation (Sinofree) in Saudi Arabian Pharmaceutical Company (SPIMACO) in Boridah El-Qaseem, Saudi Arabia instead of imported kits had been previously used.
Manual or automated measuring of antipsychotics' chemical oxygen demand.
Pereira, Sarah A P; Costa, Susana P F; Cunha, Edite; Passos, Marieta L C; Araújo, André R S T; Saraiva, M Lúcia M F S
2018-05-15
Antipsychotic (AP) drugs are becoming accumulated in terrestrial and aqueous resources due to their actual consumption. Thus, the search of methods for assessing the contamination load of these drugs is mandatory. The COD is a key parameter used for monitoring water quality upon the assessment of the effect of polluting agents on the oxygen level. Thus, the present work aims to assess the chemical oxygen demand (COD) levels of several typical and atypical antipsychotic drugs in order to obtain structure-activity relationships. It was implemented the titrimetric method with potassium dichromate as oxidant and a digestion step of 2h, followed by the measurement of remained unreduced dichromate by titration. After that, an automated sequential injection analysis (SIA) method was, also, used aiming to overcome some drawbacks of the titrimetric method. The results obtained showed a relationship between the chemical structures of antipsychotic drugs and their COD values, where the presence of aromatic rings and oxidable groups give higher COD values. It was obtained a good compliance between the results of the reference batch procedure and the SIA system, and the APs were clustered in two groups, with the values ratio between the methodologies, of 2 or 4, in the case of lower or higher COD values, respectively. The SIA methodology is capable of operating as a screening method, in any stage of a synthetic process, being also more environmentally friendly, and cost-effective. Besides, the studies presented open promising perspectives for the improvement of the effectiveness of pharmaceutical removal from the waste effluents, by assessing COD values. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Seraphin, Pierre; Gonçalvès, Julio; Vallet-Coulomb, Christine; Champollion, Cédric
2018-06-01
Spatially distributed values of the specific yield, a fundamental parameter for transient groundwater mass balance calculations, were obtained by means of three independent methods for the Crau plain, France. In contrast to its traditional use to assess recharge based on a given specific yield, the water-table fluctuation (WTF) method, applied using major recharging events, gave a first set of reference values. Then, large infiltration processes recorded by monitored boreholes and caused by major precipitation events were interpreted in terms of specific yield by means of a one-dimensional vertical numerical model solving Richards' equations within the unsaturated zone. Finally, two gravity field campaigns, at low and high piezometric levels, were carried out to assess the groundwater mass variation and thus alternative specific yield values. The range obtained by the WTF method for this aquifer made of alluvial detrital material was 2.9- 26%, in line with the scarce data available so far. The average spatial value of specific yield by the WTF method (9.1%) is consistent with the aquifer scale value from the hydro-gravimetric approach. In this investigation, an estimate of the hitherto unknown spatial distribution of the specific yield over the Crau plain was obtained using the most reliable method (the WTF method). A groundwater mass balance calculation over the domain using this distribution yielded similar results to an independent quantification based on a stable isotope-mixing model. This agreement reinforces the relevance of such estimates, which can be used to build a more accurate transient hydrogeological model.
NASA Astrophysics Data System (ADS)
Seraphin, Pierre; Gonçalvès, Julio; Vallet-Coulomb, Christine; Champollion, Cédric
2018-03-01
Spatially distributed values of the specific yield, a fundamental parameter for transient groundwater mass balance calculations, were obtained by means of three independent methods for the Crau plain, France. In contrast to its traditional use to assess recharge based on a given specific yield, the water-table fluctuation (WTF) method, applied using major recharging events, gave a first set of reference values. Then, large infiltration processes recorded by monitored boreholes and caused by major precipitation events were interpreted in terms of specific yield by means of a one-dimensional vertical numerical model solving Richards' equations within the unsaturated zone. Finally, two gravity field campaigns, at low and high piezometric levels, were carried out to assess the groundwater mass variation and thus alternative specific yield values. The range obtained by the WTF method for this aquifer made of alluvial detrital material was 2.9- 26%, in line with the scarce data available so far. The average spatial value of specific yield by the WTF method (9.1%) is consistent with the aquifer scale value from the hydro-gravimetric approach. In this investigation, an estimate of the hitherto unknown spatial distribution of the specific yield over the Crau plain was obtained using the most reliable method (the WTF method). A groundwater mass balance calculation over the domain using this distribution yielded similar results to an independent quantification based on a stable isotope-mixing model. This agreement reinforces the relevance of such estimates, which can be used to build a more accurate transient hydrogeological model.
Energy and maximum norm estimates for nonlinear conservation laws
NASA Technical Reports Server (NTRS)
Olsson, Pelle; Oliger, Joseph
1994-01-01
We have devised a technique that makes it possible to obtain energy estimates for initial-boundary value problems for nonlinear conservation laws. The two major tools to achieve the energy estimates are a certain splitting of the flux vector derivative f(u)(sub x), and a structural hypothesis, referred to as a cone condition, on the flux vector f(u). These hypotheses are fulfilled for many equations that occur in practice, such as the Euler equations of gas dynamics. It should be noted that the energy estimates are obtained without any assumptions on the gradient of the solution u. The results extend to weak solutions that are obtained as point wise limits of vanishing viscosity solutions. As a byproduct we obtain explicit expressions for the entropy function and the entropy flux of symmetrizable systems of conservation laws. Under certain circumstances the proposed technique can be applied repeatedly so as to yield estimates in the maximum norm.
A value-based medicine comparison of interventions for subfoveal neovascular macular degeneration.
Brown, Gary C; Brown, Melissa M; Brown, Heidi C; Kindermann, Sylvia; Sharma, Sanjay
2007-06-01
To perform a value-based medicine analysis of clinical trials that evaluate the interventions of laser photocoagulation, intravitreal pegaptanib therapy, and photodynamic therapy (PDT) with verteporfin for the treatment of classic subfoveal choroidal neovascularization. Reference case cost-utility analysis using value-based medicine principles, which use patient-based utility values and standardized, input variable criteria. Data from participants in the Macular Photocoagulation Study, Pegaptanib for Neovascular Age-Related Macular Degeneration Study, and the Treatment of Age-Related Macular Degeneration with Photodynamic Therapy Study. Visual data were converted to a value-based format using time tradeoff utility analysis values from patients with macular degeneration. Costs were obtained from 2005 Medicare data. Outcomes (quality-adjusted life-years [QALYs]) and costs were discounted at a 3% annual rate. Interventional QALYs gained, percent improvement in quality of life, and dollars spent per QALY gained. Laser photocoagulation confers a 4.4% (P = 0.03 versus pegaptanib therapy) improvement in quality of life for the reference case, whereas pegaptanib therapy confers a 5.9% improvement and PDT confers an 8.1% (P = 0.0002 versus pegaptanib therapy) improvement. The cost-utility associated with laser photocoagulation is $8179, that for pegaptanib therapy is $66978, and that for PDT is $31544. All sensitivity analyses remain within the conventional standards of cost-effectiveness. Photodynamic therapy confers greater patient value than intravitreal pegaptanib therapy and laser photocoagulation for the treatment of classic subfoveal choroidal neovascularization. Despite the fact that laser photocoagulation is the most cost-effective intervention, both PDT and pegaptanib therapy deliver greater value, and thus are both preferred over laser photocoagulation. Using an economic measure, photodynamic therapy is the preferred treatment among these 3 interventions.
Radiochromic film calibration for the RQT9 quality beam
NASA Astrophysics Data System (ADS)
Costa, K. C.; Gomez, A. M. L.; Alonso, T. C.; Mourao, A. P.
2017-11-01
When ionizing radiation interacts with matter it generates energy deposition. Radiation dosimetry is important for medical applications of ionizing radiation due to the increasing demand for diagnostic radiology and radiotherapy. Different dosimetry methods are used and each one has its advantages and disadvantages. The film is a dose measurement method that records the energy deposition by the darkening of its emulsion. Radiochromic films have a little visible light sensitivity and respond better to ionizing radiation exposure. The aim of this study is to obtain the resulting calibration curve by the irradiation of radiochromic film strips, making it possible to relate the darkening of the film with the absorbed dose, in order to measure doses in experiments with X-ray beam of 120 kV, in computed tomography (CT). Film strips of GAFCHROMIC XR-QA2 were exposed according to RQT9 reference radiation, which defines an X-ray beam generated from a voltage of 120 kV. Strips were irradiated in "Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear" (LCD / CDTN) at a dose range of 5-30 mGy, corresponding to the range values commonly used in CT scans. Digital images of the irradiated films were analyzed by using the ImageJ software. The darkening responses on film strips according to the doses were observed and they allowed obtaining the corresponding numeric values to the darkening for each specific dose value. From the numerical values of darkening, a calibration curve was obtained, which correlates the darkening of the film strip with dose values in mGy. The calibration curve equation is a simplified method for obtaining absorbed dose values using digital images of radiochromic films irradiated. With the calibration curve, radiochromic films may be applied on dosimetry in experiments on CT scans using X-ray beam of 120 kV, in order to improve CT acquisition image processes.
Badano, Luigi P; Cucchini, Umberto; Muraru, Denisa; Al Nono, Osama; Sarais, Cristiano; Iliceto, Sabino
2013-03-01
Since there is insufficient data available about the inter-vendor consistency of three-dimensional (3D) speckle-tracking (STE) measurements, we undertook this study to (i) assess the inter-vendor consistency of 3D LV global strain values obtained using two different scanners; (ii) identify the sources of inter-vendor inconsistencies, if any; and (iii) compare their respective intrinsic variability. Sixty patients (38 ± 12 years, 64% males) with a wide range of LV end-diastolic volumes (from 74 to 205 ml) and ejection fractions (from 17 to 70%) underwent two 3D LV data set acquisitions using VividE9 and Artida ultrasound systems. Global longitudinal (Lε), radial (Rε), circumferential (Cε) and area (Aε) strain values were obtained offline using the corresponding 3D STE softwares. Despite being significantly different, Lε showed the closest values between the two platforms (bias = 1.5%, limits of agreement (LOA) from -2.9 to -5.9%, P < 0.05). Artida produced significantly higher values of both Cε and Aε than VividE9 (bias = 6.6, LOA: -14.1 to 0.9%, and bias = 6.0, LOA = -28.2-8.6%, respectively, P < 0.001). Conversely, Rε values obtained with Artida were significantly lower than those measured using VividE9 platform (bias = -24.2, LOA: 1.5-49.9, P < 0.001). All strain components showed good reproducibility (intra-class correlation coefficients: 0.82-0.98), except for Rε by Artida, which showed only a moderate reproducibility. Apart from Lε, the inter-vendor agreement of Rε, Cε and Aε measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.
Reference values for anxiety questionnaires: the Leiden Routine Outcome Monitoring Study.
Schulte-van Maaren, Yvonne W M; Giltay, Erik J; van Hemert, Albert M; Zitman, Frans G; de Waal, Margot W M; Carlier, Ingrid V E
2013-09-25
The monitoring of patients with an anxiety disorder can benefit from Routine Outcome Monitoring (ROM). As anxiety disorders differ in phenomenology, several anxiety questionnaires are included in ROM: Brief Scale for Anxiety (BSA), PADUA Inventory Revised (PI-R), Panic Appraisal Inventory (PAI), Penn State Worry Questionnaire (PSWQ), Worry Domains Questionnaire (WDQ), Social Interaction, Anxiety Scale (SIAS), Social Phobia Scale (SPS), and the Impact of Event Scale-Revised (IES-R). We aimed to generate reference values for both 'healthy' and 'clinically anxious' populations for these anxiety questionnaires. We included 1295 subjects from the general population (ROM reference-group) and 5066 psychiatric outpatients diagnosed with a specific anxiety disorder (ROM patient-group). The MINI was used as diagnostic device in both the ROM reference group and the ROM patient group. To define limits for one-sided reference intervals (95th percentile; P95) the outermost 5% of observations were used. Receiver Operating Characteristics (ROC) analyses were used to yield alternative cut-off values for the anxiety questionnaires. For the ROM reference-group the mean age was 40.3 years (SD=12.6), and for the ROM patient-group it was 36.5 years (SD=11.9). Females constituted 62.8% of the reference-group and 64.4% of the patient-group. P95 ROM reference group cut-off values for reference versus clinically anxious populations were 11 for the BSA, 43 for the PI-R, 37 for the PAI Anticipated Panic, 47 for the PAI Perceived Consequences, 65 for the PAI Perceived Self-efficacy, 66 for the PSWQ, 74 for the WDQ, 32 for the SIAS, 19 for the SPS, and 36 for IES-R. ROC analyses yielded slightly lower reference values. The discriminative power of all eight anxiety questionnaires was very high. Substantial non-response and limited generalizability. For eight anxiety questionnaires a comprehensive set of reference values was provided. Reference values were generally higher in women than in men, implying the use of gender-specific cut-off values. Each instrument can be offered to every patient with MAS disorders to make responsible decisions about continuing, changing or terminating therapy. © 2013 Elsevier B.V. All rights reserved.
Pottumarthy, Sudha; Sader, Helio S; Fritsche, Thomas R; Jones, Ronald N
2005-11-01
Amoxicillin/clavulanate has recently undergone formulation changes (XR and ES-600) that represent 14:1 and 16:1 ratios of amoxicillin/clavulanate. These ratios greatly differ from the 2:1 ratio used in initial formulations and in vitro susceptibility testing. The objective of this study was to determine if the reference method using a 2:1 ratio accurately reflects the susceptibility to the various clinically used amoxicillin/clavulanate formulations and their respective serum concentration ratios. A collection of 330 Haemophilus influenzae strains (300 beta-lactamase-positive and 30 beta-lactamase-negative) and 40 Moraxella catarrhalis strains (30 beta-lactamase-positive and 10 beta-lactamase-negative) were tested by the broth microdilution method against eight amoxicillin/clavulanate combinations (4:1, 5:1, 7:1, 9:1, 14:1, and 16:1 ratios; 0.5 and 2 microg/mL fixed clavulanate concentrations) and the minimum inhibitory concentration (MIC) results were compared with those obtained with the reference 2:1 ratio testing. For the beta-lactamase-negative strains of both genera, there was no demonstrable change in the MIC values obtained for all ratios analyzed (2:1 to 16:1). For the beta-lactamase-positive strains of H. influenzae and M. catarrhalis, at ratios >or=4:1 there was a shift in the central tendency of the MIC scatterplot compared with the results of testing 2:1 ratio. As a result, there was a 2-fold dilution increase in the MIC(50) and MIC(90) values, most evident for H. influenzae and BRO-1-producing M. catarrhalis strains. For beta-lactamase-positive strains of H. influenzae, the shift resulted in a change in the interpretive result for 3 isolates (1.0%) from susceptible using the reference method (2:1 ratio) to resistant (8/4 microg/mL; very major error) at the 16:1 ratio. In addition, the number of isolates with MIC values at or 1 dilution lower than the breakpoint (4/2 microg/mL) increased from 5% at 2:1 ratio to 32-33% for ratios 14:1 and 16:1. Our results indicate that, for the beta-lactamase-positive strains of H. influenzae and M. catarrhalis, the results of the amoxicillin/clavulanate reference 2:1 ratio testing do not accurately represent all the currently licensed formulations. Pharmacokinetic/pharmacodynamic (PK/PD) target attainment might be compromised when higher amoxicillin/clavulanate ratios are used clinically. With a better understanding of PK/PD parameters, reevaluation of the amoxicillin/clavulanate in vitro susceptibility testing should be considered by the standardizing authorities to reflect the licensed formulations and accurately predict clinical outcomes.
Reference values of inspiratory spirometry for Finnish adults.
Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R
2018-03-07
Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.
Kainu, Annette; Lindqvist, Ari; Sovijärvi, Anssi R. A.
2016-01-01
Background New Finnish (Kainu2015) and international Global Lung Function Initiative (GLI2012) reference values for spirometry were recently published. The aim of this study is to compare the interpretative consequences of adopting these new reference values with older, currently used Finnish reference values (Viljanen1982) in the general population of native Finns. Methods Two Finnish general population samples including 1,328 adults (45% males) aged 21–74 years were evaluated. Airway obstruction was defined as a reduced ratio of forced expiratory volume in one second (FEV1)/forced vital capacity (FVC), possible restrictive pattern as reduced FVC, and decreased ventilatory capacity as reduced FEV1 below their respective 2.5th percentiles. The severity gradings of reduced lung function were also compared. Results Using the Kainu2015 reference values, the prevalence of airway obstruction in the population was 5.6%; using GLI2012 it was 4.0% and with Viljanen1982 it was 13.0%. Possible restrictive pattern was found in 4.2% using the Kainu2015 values, in 2.0% with GLI2012, and 7.9% with the Viljanen1982 values. The prevalence of decreased ventilatory capacity was 6.8, 4.0, and 13.3% with the Kainu2015, GLI2012 and Viljanen1982 values, respectively. Conclusions The application of the GLI2012 reference values underestimates the prevalence of abnormal spirometric findings in native Finns. The adoption of the Kainu2015 reference values reduces the prevalences of airways obstruction, decreased ventilatory capacity, and restrictive impairment by approximately 50%. Changing from the 2.5th percentile, the previously used lower limit of normal, to the 5th percentile recommended by the American Thoracic Society/European Respiratory Society will not increase the prevalence of abnormal findings in the implementation of spirometry reference values. PMID:27608270
Temperature calibration of cryoscopic solutions used in the milk industry by adiabatic calorimetry
NASA Astrophysics Data System (ADS)
Méndez-Lango, E.; Lira-Cortes, L.; Quiñones-Ibarra, R.
2013-09-01
One method to detect extraneous water in milk is through cryoscopy. This method is used to measure the freezing point of milk. For calibration of a cryoscope there are is a set of standardized solution with known freezing points values. These values are related with the solute concentration, based in almost a century old data; it was no found recent results. It was found that reference solution are not certified in temperature: they do not have traceability to the temperature unit or standards. We prepared four solutions and measured them on a cryoscope and on an adiabatic calorimeter. It was found that results obtained with one technique dose not coincide with the other one.
Reference values of elements in human hair: a systematic review.
Mikulewicz, Marcin; Chojnacka, Katarzyna; Gedrange, Thomas; Górecki, Henryk
2013-11-01
The lack of systematic review on reference values of elements in human hair with the consideration of methodological approach. The absence of worldwide accepted and implemented universal reference ranges causes that hair mineral analysis has not become yet a reliable and useful method of assessment of nutritional status and exposure of individuals. Systematic review of reference values of elements in human hair. PubMed, ISI Web of Knowledge, Scopus. Humans, hair mineral analysis, elements or minerals, reference values, original studies. The number of studies screened and assessed for eligibility was 52. Eventually, included in the review were 5 papers. The studies report reference ranges for the content of elements in hair: macroelements, microelements, toxic elements and other elements. Reference ranges were elaborated for different populations in the years 2000-2012. The analytical methodology differed, in particular sample preparation, digestion and analysis (ICP-AES, ICP-MS). Consequently, the levels of hair minerals reported as reference values varied. It is necessary to elaborate the standard procedures and furtherly validate hair mineral analysis and deliver detailed methodology. Only then it would be possible to provide meaningful reference ranges and take advantage of the potential that lies in Hair Mineral Analysis as a medical diagnostic technique. Copyright © 2013 Elsevier B.V. All rights reserved.
Dimai, Hans P
2017-11-01
Dual-energy X-ray absorptiometry (DXA) is a two-dimensional imaging technology developed to assess bone mineral density (BMD) of the entire human skeleton and also specifically of skeletal sites known to be most vulnerable to fracture. In order to simplify interpretation of BMD measurement results and allow comparability among different DXA-devices, the T-score concept was introduced. This concept involves an individual's BMD which is then compared with the mean value of a young healthy reference population, with the difference expressed as a standard deviation (SD). Since the early nineties of the past century, the diagnostic categories "normal, osteopenia, and osteoporosis", as recommended by a WHO working Group, are based on this concept. Thus, DXA is still the globally accepted "gold-standard" method for the noninvasive diagnosis of osteoporosis. Another score obtained from DXA measurement, termed Z-score, describes the number of SDs by which the BMD in an individual differs from the mean value expected for age and sex. Although not intended for diagnosis of osteoporosis in adults, it nevertheless provides information about an individual's fracture risk compared to peers. DXA measurement can either be used as a "stand-alone" means in the assessment of an individual's fracture risk, or incorporated into one of the available fracture risk assessment tools such as FRAX® or Garvan, thus improving the predictive power of such tools. The issue which reference databases should be used by DXA-device manufacturers for T-score reference standards has been recently addressed by an expert group, who recommended use National Health and Nutrition Examination Survey III (NHANES III) databases for the hip reference standard but own databases for the lumbar spine. Furthermore, in men it is recommended use female reference databases for calculation of the T-score and use male reference databases for calculation of Z-score. Copyright © 2017 Elsevier Inc. All rights reserved.
The theory of reference values: an unfinished symphony.
Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter
2013-01-01
The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!
[Written drug advertisements--are they reliable?].
Solhaug, Håvard Rein; Indermo, Hanne; Slørdal, Lars; Spigset, Olav
2006-05-11
Drug advertisements affect the practice and continuous education of physicians. We assessed whether drug advertisements in Norway were in accordance with national regulations in the field. All drug advertisements received by three general practitioners during a period of three months were collected. One advertisement for each of the 50 pharmaceutical products most frequently advertised was reviewed, available references obtained, and the information evaluated in relation to Norwegian regulations. A total of 294 advertisements for 77 different products were reviewed. The 50 chosen advertisements contained 191 reference citations, of which 93% were retrieved. The originator of the advertisement in question provided 72% of the references we asked for. We identified 262 promotional claims for which the regulations require a reference citation. Of these, 135 (52%) did not comply with the regulations, including 15 (6%) that were false. Only half of the information presented in drug advertisements was correct and clinically relevant. Relatively few statements were false, but a considerable proportion of statements gave an excessively positive picture of the product; hence, in general, this kind of information has no value as a source of information.
Michel, H; Levent, D; Barci, V; Barci-Funel, G; Hurel, C
2008-02-15
A new sequential method for the determination of both natural (U, Th) and anthropogenic (Sr, Cs, Pu, Am) radionuclides has been developed for application to soil and sediment samples. The procedure was optimised using a reference sediment (IAEA-368) and reference soils (IAEA-375 and IAEA-326). Reference materials were first digested using acids (leaching), 'total' acids on hot plate, and acids in microwave in order to compare the different digestion technique. Then, the separation and purification were made by anion exchange resin and selective extraction chromatography: transuranic (TRU) and strontium (SR) resins. Natural and anthropogenic alpha radionuclides were separated by uranium and tetravalent actinide (UTEVA) resin, considering different acid elution medium. Finally, alpha and gamma semiconductor spectrometer and liquid scintillation spectrometer were used to measure radionuclide activities. The results obtained for strontium-90, cesium-137, thorium-232, uranium-238, plutonium-239+240 and americium-241 isotopes by the proposed method for the reference materials provided excellent agreement with the recommended values and good chemical recoveries. Plutonium isotopes in alpha spectrometry planchet deposits could be also analysed by ICPMS.
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
Gaia FGK benchmark stars: Metallicity
NASA Astrophysics Data System (ADS)
Jofré, P.; Heiter, U.; Soubiran, C.; Blanco-Cuaresma, S.; Worley, C. C.; Pancino, E.; Cantat-Gaudin, T.; Magrini, L.; Bergemann, M.; González Hernández, J. I.; Hill, V.; Lardo, C.; de Laverny, P.; Lind, K.; Masseron, T.; Montes, D.; Mucciarelli, A.; Nordlander, T.; Recio Blanco, A.; Sobeck, J.; Sordo, R.; Sousa, S. G.; Tabernero, H.; Vallenari, A.; Van Eck, S.
2014-04-01
Context. To calibrate automatic pipelines that determine atmospheric parameters of stars, one needs a sample of stars, or "benchmark stars", with well-defined parameters to be used as a reference. Aims: We provide detailed documentation of the iron abundance determination of the 34 FGK-type benchmark stars that are selected to be the pillars for calibration of the one billion Gaia stars. They cover a wide range of temperatures, surface gravities, and metallicities. Methods: Up to seven different methods were used to analyze an observed spectral library of high resolutions and high signal-to-noise ratios. The metallicity was determined by assuming a value of effective temperature and surface gravity obtained from fundamental relations; that is, these parameters were known a priori and independently from the spectra. Results: We present a set of metallicity values obtained in a homogeneous way for our sample of benchmark stars. In addition to this value, we provide detailed documentation of the associated uncertainties. Finally, we report a value of the metallicity of the cool giant ψ Phe for the first time. Based on NARVAL and HARPS data obtained within the Gaia DPAC (Data Processing and Analysis Consortium) and coordinated by the GBOG (Ground-Based Observations for Gaia) working group and on data retrieved from the ESO-ADP database.Tables 6-76 are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/564/A133
NASA Technical Reports Server (NTRS)
Drews, D.; Stein, T. P.
1992-01-01
The doubly labeled water (DLW, 2H(2)18O) method is a highly accurate method for measuring energy expenditure (EE). A possible source of error is bolus fluid intake before body water sampling. If there is bolus fluid intake immediately before body water sampling, the saliva may reflect the ingested water disproportionately, because the ingested water may not have had time to mix fully with the body water pool. To ascertain the magnitude of this problem, EE was measured over a 5-day period by the DLW method. Six subjects were dosed with 2H2(18)O. After the reference salivas for the two-point determination were obtained, subjects drank water (700-1,000 ml), and serial saliva samples were collected for the next 3 h. Expressing the postbolus saliva enrichments as a percentage of the prebolus value, we found 1) a minimum in the saliva isotopic enrichments were reached at approximately 30 min with the minimum for 2H (95.48 +/- 0.43%) being significantly lower than the minimum for 18O (97.55 +/- 0.44, P less than 0.05) and 2) EE values calculated using the postbolus isotopic enrichments are appreciably higher (19.9 +/- 7.5%) than the prebolus reference values. In conclusion, it is not advisable to collect saliva samples for DLW measurements within approximately 1 h of bolus fluid intake.
Santos, Bruna F A; Souza, Hugo C D; Miranda, Aline P B; Cipriano, Federico G; Gastaldi, Ada C
2016-01-01
To assess functional capacity in the preoperative phase of pulmonary surgery by comparing predicted and obtained values for the six-minute walk test (6MWT) in patients with and without postoperative pulmonary complication (PPC) METHOD: Twenty-one patients in the preoperative phase of open thoracotomy were evaluated using the 6MWT, followed by monitoring of the postoperative evolution of each participant who underwent the routine treatment. Participants were then divided into two groups: the group with PPC and the group without PPC. The results were also compared with the predicted values using reference equations for the 6MWT RESULTS: Over half (57.14%) of patients developed PPC. The 6MWT was associated with the odds for PPC (odds ratio=22, p=0.01); the group without PPC in the postoperative period walked 422.38 (SD=72.18) meters during the 6MWT, while the group with PPC walked an average of 340.89 (SD=100.93) meters (p=0.02). The distance traveled by the group without PPC was 80% of the predicted value, whereas the group with PPC averaged less than 70% (p=0.03), with more appropriate predicted values for the reference equations The 6MWT is an easy, safe, and feasible test for routine preoperative evaluation in pulmonary surgery and may indicate patients with a higher chance of developing PPC.
Validity of Three-Dimensional Photonic Scanning Technique for Estimating Percent Body Fat.
Shitara, K; Kanehisa, H; Fukunaga, T; Yanai, T; Kawakami, Y
2013-01-01
Three-dimensional photonic scanning (3DPS) was recently developed to measure dimensions of a human body surface. The purpose of this study was to explore the validity of body volume measured by 3DPS for estimating the percent body fat (%fat). Design, setting, participants, and measurement: The body volumes were determined by 3DPS in 52 women. The body volume was corrected for residual lung volume. The %fat was estimated from body density and compared with the corresponding reference value determined by the dual-energy x-ray absorptiometry (DXA). No significant difference was found for the mean values of %fat obtained by 3DPS (22.2 ± 7.6%) and DXA (23.5 ± 4.9%). The root mean square error of %fat between 3DPS and reference technique was 6.0%. For each body segment, there was a significant positive correlation between 3DPS- and DXA-values, although the corresponding value for the head was slightly larger in 3DPS than in DXA. Residual lung volume was negatively correlated with the estimated error in %fat. The body volume determined with 3DPS is potentially useful for estimating %fat. A possible strategy for enhancing the measurement accuracy of %fat might be to refine the protocol for preparing the subject's hair prior to scanning and to improve the accuracy in the measurement of residual lung volume.
Qi, Haiping; Lorenz, Jennifer M.; Coplen, Tyler B.; Tarbox, Lauren V.; Mayer, Bernhard; Taylor, Steve
2014-01-01
RESULTS: The δ2H and δ18O values of this reference water are –150.2 ± 0.5 ‰ and –19.80 ± 0.02 ‰, respectively, relative to VSMOW on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. CONCLUSION: This isotopic reference material, designated as USGS47, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and stable oxygen isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. "
NASA Astrophysics Data System (ADS)
Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin
2017-06-01
In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady-state diffusion equation. For the in vitro experiments, floating reference positions exist in 1220 nm and 1320 nm under two types of light source, and the results are quite close. However, the reference positions obtained from experiments are further from the light source compared with those obtained in the MC simulation. For the turbid media and the wavelengths investigated, the difference is up to 1 mm. This study is important for the design of optical fibers to be applied in the floating reference measurement.
2012-06-01
Reference values of maximum isometric muscle force obtained in 270 children aged 4-16 years by hand-held dynamometry. Neuromuscul Disord. 2001;11(5...evaluation of specific muscle groups responsible for fatigue-related changes. Since fiber type proportion is determined by its innervation, evaluating muscle ... fiber output provides down-stream information about the integrity of the motor neuron. Objective To determine the association between muscle
Laser detection of CO2 concentration in human breath at various diseases
NASA Astrophysics Data System (ADS)
Ageev, Boris G.; Nikiforova, Olga Y.
2015-12-01
Absorption spectra of human breath in 10 μm region were recorded by the use of intracavity laser photo-acoustic gas analyzer based on tunable waveguide CO2 laser. Healthy persons and patients with various diseases were studied. For determination of CO2 concentration in exhalation samples gas analyzer was calibrated by reference gaseous mixture CO2-N2. It was obtained that CO2 concentration values in human breath of healthy persons are greater than that of patients with various diseases.
Attitudes towards fertility control.
Muthal, S
1992-03-01
"The present work aims to determine...the effectiveness of traditional mixed and modern attitudes towards fertility. Here fertility refers to the number of children actually born to a woman. Randomly chosen 400 women belonging to different ethnic strains from Sagar town [India] constitute the data for the present study. The scaling technique is devised to obtain accurate values for fertility noticed among different populations. Thus an attempt has been made to study whether education, income, caste, age and age at marriage have direct association with fertility." excerpt
The hydrogen atom in D = 3 - 2ɛ dimensions
NASA Astrophysics Data System (ADS)
Adkins, Gregory S.
2018-06-01
The nonrelativistic hydrogen atom in D = 3 - 2 ɛ dimensions is the reference system for perturbative schemes used in dimensionally regularized nonrelativistic effective field theories to describe hydrogen-like atoms. Solutions to the D-dimensional Schrödinger-Coulomb equation are given in the form of a double power series. Energies and normalization integrals are obtained numerically and also perturbatively in terms of ɛ. The utility of the series expansion is demonstrated by the calculation of the divergent expectation value <(V‧)2 >.
Dynamics of actual aggregation of petroleum products in snow cover
NASA Astrophysics Data System (ADS)
Begunova, L. A.; Kuznetsova, O. V.; Begunov, D. A.; Kuznetsova, A. N.
2017-11-01
The paper presents issues of snow cover pollution by petroleum products. Petroleum products content was determined using the fluorimetric method of analysis. The samples of snow were selected on the territory of Angarsk and Irkutsk cities. According to the obtained data, the content of petroleum products in the analyzed samples exceeds the background value up to 6 times. Analysis of the reference data for similar research confirms need for creation of an environmental monitoring centralized system to monitor atmospheric precipitation and, particularly, snow cover.
Zacharasiewicz, Angela; Renner, Sabine; Haderer, Flora; Weber, Michael; Dehlink, Eleonore; Szepfalusi, Zsolt; Frischer, Thomas
2017-08-01
Interpretation of lung function values in children with cystic fibrosis (CF) depends on the applied reference values. We hypothesize that differences between the new global lung function initiative (GLI) values and the formerly used Zapletal et al. values produce significantly different clinical results. We analyzed 3719 lung function measurements of 108 children and adolescents (n = 54 male; aged 6-18 years) with CF treated between September 1991 and July 2009. Data were analyzed in milliliters (ml) and % predicted (pred.) and interpreted using Zapletal and GLI reference values. Applying GLI compared to Zapletal resulted in significantly lower mean forced expiratory volume in 1s (FEV1)% pred. Zapletal 86.6% (SD 20.6), GLI 79.9% (SD 20.3) and 32% (n = 497/1543) were misclassified as normal when using Zapletal. Despite showing no overall differences in FEV1 and forced vital capacity (FVC) between concomitant Pseudomonas detection (PA+) in n = 938 and Pseudomonas negative (PA-) (n = 2781) using either reference PA+ resulted in lower FEV1 and FVC values with increasing age; however, measurement of small airway obstruction with forced expiratory flow at 75% of FVC (FEF75) values - available for Zapletal -showed significant differences. Reassurance regarding lung function when using old reference values may occur with potential clinical significance. Discrepancies in lung function interpretation underline the importance of using uniform and best available reference values.
Estimate of the uncertainty in measurement for the determination of mercury in seafood by TDA AAS.
Torres, Daiane Placido; Olivares, Igor R B; Queiroz, Helena Müller
2015-01-01
An approach for the estimate of the uncertainty in measurement considering the individual sources related to the different steps of the method under evaluation as well as the uncertainties estimated from the validation data for the determination of mercury in seafood by using thermal decomposition/amalgamation atomic absorption spectrometry (TDA AAS) is proposed. The considered method has been fully optimized and validated in an official laboratory of the Ministry of Agriculture, Livestock and Food Supply of Brazil, in order to comply with national and international food regulations and quality assurance. The referred method has been accredited under the ISO/IEC 17025 norm since 2010. The approach of the present work in order to reach the aim of estimating of the uncertainty in measurement was based on six sources of uncertainty for mercury determination in seafood by TDA AAS, following the validation process, which were: Linear least square regression, Repeatability, Intermediate precision, Correction factor of the analytical curve, Sample mass, and Standard reference solution. Those that most influenced the uncertainty in measurement were sample weight, repeatability, intermediate precision and calibration curve. The obtained result for the estimate of uncertainty in measurement in the present work reached a value of 13.39%, which complies with the European Regulation EC 836/2011. This figure represents a very realistic estimate of the routine conditions, since it fairly encompasses the dispersion obtained from the value attributed to the sample and the value measured by the laboratory analysts. From this outcome, it is possible to infer that the validation data (based on calibration curve, recovery and precision), together with the variation on sample mass, can offer a proper estimate of uncertainty in measurement.
Vriz, Olga; Aboyans, Victor; Minisini, Rosalba; Magne, Julien; Bertin, Nicole; Pirisi, Mario; Bossone, Eduardo
2017-07-01
Arterial stiffness can predict cardiovascular events, and the aim of this study was to produce age- and sex-specific reference values for echo-tracking carotid stiffness in healthy subjects. A total of 900 subjects (500 males, mean age 45.8±19 years) were enrolled. Common carotid artery stiffness and compliance, using a high-definition echo-tracking ultrasound system, were evaluated. To compare stiffness parameters across the different age groups, individual scores were transformed into T-scores, indicating how many standard deviation (s.d.) units an individual's score was above or below the mean that was observed in the group including same-sex individuals aged 36 to 44 years. Carotid stiffness was similar among genders, except compliance, which was lower in women (P<0.0001). These characteristics were also maintained when the studied population was divided into seven age groups. Stiffness parameters increased significantly with age, but the opposite occurred for compliance. The T-score was found to increase significantly across all age groups, with a steeper increase in stiffness around the age of 60 years in women. For each T-score s.d., the corresponding carotid absolute values for arterial stiffness and compliance were obtained. In a multivariate model, carotid stiffness parameters were constantly and independently associated with age, mean arterial pressure, pulse pressure, heart rate and body mass index. Our study provides a normogram of carotid arterial stiffness and compliance indices obtained with the echo-tracking method in a large population of healthy subjects stratified by gender and age that can be used in clinical practice.
An isothermal equation of state for solids
NASA Astrophysics Data System (ADS)
Bose Roy, Papiya; Bose Roy, Sushil
2004-07-01
An isothermal equation of state (EOS) for solids, recently suggested by the authors in the realistic form, V/ V0= f( P), with relative volume as the dependent and the pressure as the independent variable, was shown to have an advantage for some close-packed materials in that it allows B‧ ∞=(∂ Bs/∂ P) s( P→∞) to be fitted, and this is where the usual standard equations fail. In the present study, our EOS is applied to a number of inorganic as well as organic solids, including alloys, glasses, rubbers and plastics; varying widely in their bonding and structural characteristics, as well as in their bulk modulus values. A very good agreement is observed between the data and fits. The results obtained are compared with those from two well-known equations, expressible in the realistic form, proposed by Murnaghan and Luban. Further, the results are also compared with those from the widely used two- and three-parameter EOSs, expressible in the unrealistic form only, P= f( V/ V0), proposed by Birch-and also with those from the EOS model of Keane in which B‧ ∞ is explicitly expressed as an equation of state parameter. The results obtained from our model compare well to these EOSs. Our EOS, in general, yields the smallest mean-squared deviations between data and fits. The values of B‧ ∞calculated from our EOS are compared with those from Keane's model. Further, we have studied the variation of B‧ ∞with temperature using the experimental isotherms of Mo and W at 10 different temperatures ranging from 100 to 1000 K, and observed that the values of B‧ ∞ yielded by our model and that of Keane vary, as expected, within a narrow range. Furthermore, our EOS is applied to study the stability of the fit parameters with variation in the pressure ranges with reference to the isothermal compression data on Mo and W-and also to study the variation of isothermal bulk modulus with pressure, with reference to the ultrasonic data on NaCl and noted a very good agreement with experiment. In addition, our model is applied, with B0 and B‧ 0 constrained to the theoretical values, to the five theoretical isotherms of MgO at 300, 500, 1000, 1500 and 2000 K obtained on the basis of a first principles approach-a good agreement is observed with the predictions, and the values of B‧ ∞ inferred at different temperatures tend to converge to a constant value.
Development of a paediatric population-based model of the pharmacokinetics of rivaroxaban.
Willmann, Stefan; Becker, Corina; Burghaus, Rolf; Coboeken, Katrin; Edginton, Andrea; Lippert, Jörg; Siegmund, Hans-Ulrich; Thelen, Kirstin; Mück, Wolfgang
2014-01-01
Venous thromboembolism has been increasingly recognised as a clinical problem in the paediatric population. Guideline recommendations for antithrombotic therapy in paediatric patients are based mainly on extrapolation from adult clinical trial data, owing to the limited number of clinical trials in paediatric populations. The oral, direct Factor Xa inhibitor rivaroxaban has been approved in adult patients for several thromboembolic disorders, and its well-defined pharmacokinetic and pharmacodynamic characteristics and efficacy and safety profiles in adults warrant further investigation of this agent in the paediatric population. The objective of this study was to develop and qualify a physiologically based pharmacokinetic (PBPK) model for rivaroxaban doses of 10 and 20 mg in adults and to scale this model to the paediatric population (0-18 years) to inform the dosing regimen for a clinical study of rivaroxaban in paediatric patients. Experimental data sets from phase I studies supported the development and qualification of an adult PBPK model. This adult PBPK model was then scaled to the paediatric population by including anthropometric and physiological information, age-dependent clearance and age-dependent protein binding. The pharmacokinetic properties of rivaroxaban in virtual populations of children were simulated for two body weight-related dosing regimens equivalent to 10 and 20 mg once daily in adults. The quality of the model was judged by means of a visual predictive check. Subsequently, paediatric simulations of the area under the plasma concentration-time curve (AUC), maximum (peak) plasma drug concentration (C max) and concentration in plasma after 24 h (C 24h) were compared with the adult reference simulations. Simulations for AUC, C max and C 24h throughout the investigated age range largely overlapped with values obtained for the corresponding dose in the adult reference simulation for both body weight-related dosing regimens. However, pharmacokinetic values in infants and preschool children (body weight <40 kg) were lower than the 90 % confidence interval threshold of the adult reference model and, therefore, indicated that doses in these groups may need to be increased to achieve the same plasma levels as in adults. For children with body weight between 40 and 70 kg, simulated plasma pharmacokinetic parameters (C max, C 24h and AUC) overlapped with the values obtained in the corresponding adult reference simulation, indicating that body weight-related exposure was similar between these children and adults. In adolescents of >70 kg body weight, the simulated 90 % prediction interval values of AUC and C 24h were much higher than the 90 % confidence interval of the adult reference population, owing to the weight-based simulation approach, but for these patients rivaroxaban would be administered at adult fixed doses of 10 and 20 mg. The paediatric PBPK model developed here allowed an exploratory analysis of the pharmacokinetics of rivaroxaban in children to inform the dosing regimen for a clinical study in paediatric patients.
Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; Motroni, Alessandro; van der Stelt, Paul; Wismeijer, Daniel
2012-01-01
To assess the reliability of cone beam computed tomography (CBCT) voxel gray value measurements using Hounsfield units (HU) derived from multislice computed tomography (MSCT) as a clinical reference (gold standard). Ten partially edentulous human mandibular cadavers were scanned by two types of computed tomography (CT) modalities: multislice CT and cone beam CT. On MSCT scans, eight regions of interest (ROI) designating the site for preoperative implant placement were selected in each mandible. The datasets from both CT systems were matched using a three-dimensional (3D) registration algorithm. The mean voxel gray values of the region around the implant sites were compared between MSCT and CBCT. Significant differences between the mean gray values obtained by CBCT and HU by MSCT were found. In all the selected ROIs, CBCT showed higher mean values than MSCT. A strong correlation (R=0.968) between mean voxel gray values of CBCT and mean HU of MSCT was determined. Voxel gray values from CBCT deviate from actual HU units. However, a strong linear correlation exists, which may permit deriving actual HU units from CBCT using linear regression models.
2017-01-01
Real-time quantitative PCR (qPCR) is the most reliable and accurate technique for analyses of gene expression. Endogenous reference genes are being used to normalize qPCR data even though their expression may vary under different conditions and in different tissues. Nonetheless, verification of expression of reference genes in selected studied tissue is essential in order to accurately assess the level of expression of target genes of interest. Therefore, in this study, we attempted to examine six commonly used reference genes in order to identify the gene being expressed most constantly under the influence of testosterone in the kidneys and hypothalamus. The reference genes include glyceraldehyde-3-phosphate dehydrogenase (GAPDH), actin beta (ACTB), beta-2 microglobulin (B2m), hypoxanthine phosphoribosyltransferase 1 (HPRT), peptidylprolylisomerase A (Ppia) and hydroxymethylbilane synthase (Hmbs). The cycle threshold (Ct) value for each gene was determined and data obtained were analyzed using the software programs NormFinder, geNorm, BestKeeper, and rank aggregation. Results showed that Hmbs and Ppia genes were the most stably expressed in the hypothalamus. Meanwhile, in kidneys, Hmbs and GAPDH appeared to be the most constant genes. In conclusion, variations in expression levels of reference genes occur in kidneys and hypothalamus under similar conditions; thus, it is important to verify reference gene levels in these tissues prior to commencing any studies. PMID:28591185
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geslot, Benoit; Pepino, Alexandra; Blaise, Patrick
A pile noise measurement campaign has been conducted by the CEA in the VENUS-F reactor (SCK-CEN, Mol Belgium) in April 2011 in the reference critical configuration of the GUINEVERE experimental program. The experimental setup made it possible to estimate the core kinetic parameters: the prompt neutron decay constant, the delayed neutron fraction and the generation time. A precise assessment of these constants is of prime importance. In particular, the effective delayed neutron fraction is used to normalize and compare calculated reactivities of different subcritical configurations, obtained by modifying either the core layout or the control rods position, with experimental onesmore » deduced from the analysis of measurements. This paper presents results obtained with a CEA-developed time stamping acquisition system. Data were analyzed using Rossi-α and Feynman-α methods. Results were normalized to reactor power using a calibrated fission chamber with a deposit of Np-237. Calculated factors were necessary to the analysis: the Diven factor was computed by the ENEA (Italy) and the power calibration factor by the CNRS/IN2P3/LPC Caen. Results deduced with both methods are consistent with respect to calculated quantities. Recommended values are given by the Rossi-α estimator, that was found to be the most robust. The neutron generation time was found equal to 0.438 ± 0.009 μs and the effective delayed neutron fraction is 765 ± 8 pcm. Discrepancies with the calculated value (722 pcm, calculation from ENEA) are satisfactory: -5.6% for the Rossi-α estimate and -2.7% for the Feynman-α estimate. (authors)« less
Simply scan--optical methods for elemental carbon measurement in diesel exhaust particulate.
Forder, James A
2014-08-01
This article describes a performance assessment of three optical methods, a Magee Scientific OT21 Transmissometer, a Hach-Lange Microcolor II difference gloss meter, and a combination of an office scanner with Adobe Photoshop software. The optical methods measure filter staining as a proxy for elemental carbon in diesel exhaust particulate (DEP) exposure assessment and the suitability of each as a replacement for the existing Bosch meter optical method. Filters loaded with DEP were produced from air in a non-coal mine and the exhaust gases from a mobile crane. These were measured with each apparatus and then by combustion to obtain a reference elemental carbon value. The results from each apparatus were then plotted against both the Bosch number and reference elemental carbon values. The equations of the best fit lines for these plots were derived, and these gave functions for elemental carbon and Bosch number from the output of each new optical method. For each optical method, the range of DEP loadings which can be measured has been determined, and conversion equations for elemental carbon and Bosch number have been obtained. All three optical methods studied will effectively quantify blackness as a measure of elemental carbon. Of these the Magee Scientific OT21 transmissometer has the best performance. The Microcolor II and scanner/photoshop methods will in addition allow conversion to Bosch number which may be useful if historical Bosch data are available and functions for this are described. The scanner/photoshop method demonstrates a technique to obtain measurements of DEP exposure without the need to purchase specialized instrumentation. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Determination of iprodione in agrochemicals by infrared and Raman spectrometry.
Armenta, Sergio; Garrigues, Salvador; de la Guardia, Miguel
2007-04-01
Two methodologies based on vibrational spectrometry--making use of Fourier transform infrared absorption (FTIR) and Raman spectrometry--were developed for iprodione determination in solid pesticide formulations. The FTIR procedure involved the extraction of iprodione by CHCl(3), and the latter determination involved measuring the peak area between 1450 and 1440 cm(-1), corrected using a horizontal baseline defined at 1481 cm(-1). FT-Raman determination was performed directly on the powdered solid products, using standard chromatography glass vials as sample cells and measuring the Raman intensity between 1003 and 993 cm(-1), with a two-point baseline correction established between 1012 and 981 cm(-1). The sensitivities obtained were 0.319 area values g mg(-1) for FTIR determination and 5.58 area values g g(-1) for FT-Raman. The repeatabilities, taken to be the relative standard deviation of five independent measurements at 1.51 mg g(-1) and 10.98% w/w concentration levels, were equal to 0.16% and 0.9% for FTIR and FT-Raman, respectively, and the limits of detection were 0.3 and 0.2% w/w (higher than those obtained for HPLC, 0.016% w/w). FTIR determination provided a sample frequency of 60 h(-1), higher than those obtained for the Raman and reference chromatography methods (25 and 8.6 h(-1), respectively). On the other hand, the new FT-Raman method eliminates reagent consumption and waste generation, and reduces the need for sample handling and the contact of operator with the pesticide. In spite of their lack of sensitivity, vibrational procedures can therefore provide viable environmentally friendly alternatives to laborious, time- and solvent-consuming reference chromatography methods for quality control in commercially available pesticide formulations.
Mann, J. John; Ogden, R. Todd
2017-01-01
Background and aim Estimation of a PET tracer’s non-displaceable distribution volume (VND) is required for quantification of specific binding to its target of interest. VND is generally assumed to be comparable brain-wide and is determined either from a reference region devoid of the target, often not available for many tracers and targets, or by imaging each subject before and after blocking the target with another molecule that has high affinity for the target, which is cumbersome and involves additional radiation exposure. Here we propose, and validate for the tracers [11C]DASB and [11C]CUMI-101, a new data-driven hybrid deconvolution approach (HYDECA) that determines VND at the individual level without requiring either a reference region or a blocking study. Methods HYDECA requires the tracer metabolite-corrected concentration curve in blood plasma and uses a singular value decomposition to estimate the impulse response function across several brain regions from measured time activity curves. HYDECA decomposes each region’s impulse response function into the sum of a parametric non-displaceable component, which is a function of VND, assumed common across regions, and a nonparametric specific component. These two components differentially contribute to each impulse response function. Different regions show different contributions of the two components, and HYDECA examines data across regions to find a suitable common VND. HYDECA implementation requires determination of two tuning parameters, and we propose two strategies for objectively selecting these parameters for a given tracer: using data from blocking studies, and realistic simulations of the tracer. Using available test-retest data, we compare HYDECA estimates of VND and binding potentials to those obtained based on VND estimated using a purported reference region. Results For [11C]DASB and [11C]CUMI-101, we find that regardless of the strategy used to optimize the tuning parameters, HYDECA provides considerably less biased estimates of VND than those obtained, as is commonly done, using a non-ideal reference region. HYDECA test-retest reproducibility is comparable to that obtained using a VND determined from a non-ideal reference region, when considering the binding potentials BPP and BPND. Conclusions HYDECA can provide subject-specific estimates of VND without requiring a blocking study for tracers and targets for which a valid reference region does not exist. PMID:28459878
Costs, effectiveness, and workload impact of management strategies for women with an adnexal mass.
Havrilesky, Laura J; Dinan, Michaela; Sfakianos, Gregory P; Curtis, Lesley H; Barnett, Jason C; Van Gorp, Toon; Myers, Evan R
2015-01-01
We compared the estimated clinical outcomes, costs, and physician workload resulting from available strategies for deciding which women with an adnexal mass should be referred to a gynecologic oncologist. We used a microsimulation model to compare five referral strategies: 1) American Congress of Obstetricians and Gynecologists (ACOG) guidelines, 2) Multivariate Index Assay (MIA) algorithm, 3) Risk of Malignancy Algorithm (ROMA), 4) CA125 alone with lowered cutoff values to prioritize test sensitivity over specificity, 5) referral of all women (Refer All). Test characteristics and relative survival were obtained from the literature and data from a biomarker validation study. Medical costs were estimated using Medicare reimbursements. Travel costs were estimated using discharge data from Surveillance, Epidemiology and End Results-Medicare and State Inpatient Databases. Analyses were performed separately for pre- and postmenopausal women (60 000 "subjects" in each), repeated 10 000 times. Refer All was cost-effective compared with less expensive strategies in both postmenopausal (incremental cost-effectiveness ratio [ICER] $9423/year of life saved (LYS) compared with CA125) and premenopausal women (ICER $10 644/YLS compared with CA125), but would result in an additional 73 cases/year/subspecialist. MIA was more expensive and less effective than Refer All in pre- and postmenopausal women. If Refer All is not a viable option, CA125 is an optimal strategy in postmenopausal women. Referral of all women to a subspecialist is an efficient strategy for managing women with adnexal masses requiring surgery, assuming sufficient capacity for additional surgical volume. If a test-based triage strategy is needed, CA125 with lowered cutoff values is a cost-effective strategy. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Liu, Junting; Wang, Liang; Sun, Jinghui; Liu, Gongshu; Yan, Weili; Xi, Bo; Xiong, Feng; Ding, Wenqing; Huang, Guimin; Heymsfield, Steven; Mi, Jie
2017-05-29
No nationwide paediatric reference standards for bone mineral density (BMD) are available in China. We aimed to provide sex-specific BMD reference values for Chinese children and adolescents (3-18 years). Data (10 818 participants aged 3-18 years) were obtained from cross-sectional surveys of the China Child and Adolescent Cardiovascular Health in 2015, which included four municipality cities and three provinces. BMD was measured using Hologic Discovery Dual Energy X-ray Absorptiometry (DXA) scanner. The DXA measures were modelled against age, with height as an independent variable. The LMS statistical method using a curve fitting procedure was used to construct reference smooth cross-sectional centile curves for dependent versus independent variables. Children residing in Northeast China had the highest total body less head (TBLH) BMD while children residing in Shandong Province had the lowest values. Among children, TBLH BMD was higher for boys as compared with girls; but, it increased with age and height in both sexes. Furthermore, TBLH BMD was higher among US children as compared with Chinese children. There was a large difference in BMD for height among children from these two countries. US children had a much higher BMD at each percentile (P) than Chinese children; the largest observed difference was at P50 and P3 and the smallest difference was at P97. This is the first study to present a sex-specific reference dataset for Chinese children aged 3-18 years. The data can help clinicians improve interpretation, assessment and monitoring of densitometry results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, C.K.; Brown, B.G.; Reed, E.A.
A prototype cigarette that heats tobacco (test cigarette), developed by R.J. Reynolds Tobacco Company, has yielded consistently negative results in several in vivo and in vitro genetic toxicology tests. The objective of the present study was to evaluate the potential of cigarette smoke condensate (CSC) from the test cigarette to induce DNA adducts in mouse tissues and compare the results with those obtained with CSC from a reference tobacco-burning cigarette (1R4F). CD-1 mice were skin-painted with CSF from reference and test cigarettes three times a week for 4 weeks. The highest mass of CSC applied was 180 mg tar permore » week per animal for both reference and test cigarette. DNA adducts were analyzed in skin and lung tissues using the [sup 32]P-postlabeling method with the P[sub 1] nuclease modification. Distinct diagonal radioactive zones (DRZ) were observed in the DNA from both skin and lung tissues of animals dosed with reference CSC, whereas no corresponding DRZ were observed from the DNA of animals dosed with either test CSC or acetone (solvent control). The relative adduct labeling (RAL) values of skin and lung DNA from reference CSC-treated animals were significantly greater than those of the test CSC-treated animals. The RAL values of the test CSC-treated animals were no greater than those of solvent controls. The negative results in DNA adduct assays with test CSC are consistent with all previous results of in vivo and in vitro genetic toxicology testing on this cigarette and provide additional evidence that smoke condensate from the test cigarette is not genotoxic. 31 refs., 4 figs., 2 tabs.« less
Glacial isostatic adjustment using GNSS permanent stations and GIA modelling tools
NASA Astrophysics Data System (ADS)
Kollo, Karin; Spada, Giorgio; Vermeer, Martin
2013-04-01
Glacial Isostatic Adjustment (GIA) affects the Earth's mantle in areas which were once ice covered and the process is still ongoing. In this contribution we focus on GIA processes in Fennoscandian and North American uplift regions. In this contribution we use horizontal and vertical uplift rates from Global Navigation Satellite System (GNSS) permanent stations. For Fennoscandia the BIFROST dataset (Lidberg, 2010) and North America the dataset from Sella, 2007 were used respectively. We perform GIA modelling with the SELEN program (Spada and Stocchi, 2007) and we vary ice model parameters in space in order to find ice model which suits best with uplift values obtained from GNSS time series analysis. In the GIA modelling, the ice models ICE-5G (Peltier, 2004) and the ice model denoted as ANU05 ((Fleming and Lambeck, 2004) and references therein) were used. As reference, the velocity field from GNSS permanent station time series was used for both target areas. Firstly the sensitivity to the harmonic degree was tested in order to reduce the computation time. In the test, nominal viscosity values and pre-defined lithosphere thicknesses models were used, varying maximum harmonic degree values. Main criteria for choosing the suitable harmonic degree was chi-square fit - if the error measure does not differ more than 10%, then one might use as well lower harmonic degree value. From this test, maximum harmonic degree of 72 was chosen to perform calculations, as the larger value did not significantly modify the results obtained, as well the computational time for observations was kept reasonable. Secondly the GIA computations were performed to find the model, which could fit with highest probability to the GNSS-based velocity field in the target areas. In order to find best fitting Earth viscosity parameters, different viscosity profiles for the Earth models were tested and their impact on horizontal and vertical velocity rates from GIA modelling was studied. For every tested model the chi-square misfit for horizontal, vertical and three-dimensional velocity rates from the reference model was found (Milne, 2001). Finally, the best fitting models from GIA modelling were compared with rates obtained from GNSS data. Keywords: Fennoscandia, North America, land uplift, glacial isostatic adjustment, visco-elastic modelling, BIFROST. References Lidberg, M., Johannson, J., Scherneck, H.-G. and Milne, G. (2010). Recent results based on continuous GPS observations of the GIA process in Fennoscandia from BIFROST. Journal of Geodynamics, 50. pp. 8-18. Sella, G. F., Stein, S., Dixon, T. H., Craymer, M., James, T. S., Mazotti, S. and Dokka, R. K. (2007). Observations of glacial isostatic adjustment in "stable" North America with GPS. Geophysical Research Letters, 34, L02306. Spada, G., Stocchi, P. (2007). SELEN: A Fortran 90 program for solving the "sea-level equation". Computers & Geosciences, 33:538-562, 2007. Peltier, W. R. (2004). Global glacial isostasy and the surface of the ice-age Earth: The Ice-5G (VM2) model and GRACE. Annu. Rev. Earth Planet. Sci., 32:111-149, 2004. Fleming, K. and Lambeck, K. (2004). Constraints on the Greenland Ice Sheet since the Last Glacial Maximum from sea-level observations and glacial-rebound models. Quaternary Science Reviews 23 (2004), pp. 1053-1077. Milne, G. A. and Davis, J. L. and Mitrovica, J. X. and Scherneck, H.-G. and Johansson, J. M. and Vermeer, M. and Koivula, H. (2001). Space-geodetic constraints on glacial isostatic adjustment in Fennoscandia. Science 291 (2001), pp. 2381-2385.
NASA Astrophysics Data System (ADS)
Komissarova, Olga; Paramonova, Tatiana
2017-04-01
One of the notable lessons obtained from nuclear accidents could be revealing the general features of 137Cs root uptake by agricultural crops for prediction the radionuclide accumulation in plants and its further distribution via food chains. Transfer factors (TFs) (the ratio of 137Cs activities in vegetation and in soil) have become a basis for such assessment when the characteristics of radioactive contamination, soil properties and phylogenetic features of different plant taxons important for root uptake are known. For the sake of simplicity the concept of conversion factor (CF) was accepted by IAEA (2006) to obtain unknown value of TF from the TF value of the reference crop cultivated on the same soil. Cereals were selected like reference group of agricultural crops. Presuming TF for cereals equal 1, CFs for tubers and fodder leguminous are 4, for grasses - 4.5, for leafy vegetables - 9, ets. To verify TFs and corresponding CFs values under environmental conditions of post-Chernobyl agricultural landscape the study in the area of Plavsky radioactive hotspot (Tula region, Russia) was conducted. Nowadays, after 30 years after the Chernobyl accident ( the first half-life period of 137Cs), arable chernozems of the territory are still polluted at the level 126-282 kBq/m2. The main crops of field rotation: wheat and barley (cereals), potatoes (tubers), soybean (leguminous), amaranth (non-leafy vegetables), rape ("other crops"), as well as galega-bromegrass mixture (cultivated species of grasses) and pasture grasses of semi-natural dry and wet meadows have been studied. Accumulation parameters of 137Cs in aboveground biomass, belowground biomass and edible parts of the plants were examined separately. Experimentally obtained 137Cs TFs in cereals are 0.24-0.32 for total biomass, 0.07-0.14 for aerial parts, 0.54-0.64 for roots and 0.01-0.02 for grain. Thus, (i) 137Cs transfer in grain of wheat and barley is insignificant and (ii) corresponding TFs values in both crops are reasonably consistent with each other. Normalizing 137Cs TFs in investigated crops to the mean TF value for the grain of cereals, the following CFs are realized: 0.8 for potatoes and 1.0 for rape, 1.4-3.5 for cultivated species of grasses and almost the same - 1.3-3.2 - for pasture grasses, 5.8 for soybean, 7.0 for amaranth. The data are not exactly, but satisfactory agree with IAEA recommendations and have revealed the similar order of CFs for plant groups. Another situation is found when CFs are calculated on the basis of 137Cs TFs in aboveground and especially in total biomass of cereals. Since wheat and barley are capable to accumulate relatively elevated amount of the radionuclide in roots and definite 137Cs is translocated into leaves and stems, such CFs for crops are estimated as <0.8 and <0.6 taking into account average TFs in aboveground and total biomass of cereals correspondently. Hence cultural cereals are more likely accumulators of 137Cs rather than excluders. As a whole, the concept of conversion factors and reference crops for the prediction of 137Cs transfer into plants have considerable promise, but invites further investigation and precise observing conditions. The study was conducted with the support from the RFBR (14-05-00903).
Reference-dependent risk sensitivity as rational inference.
Denrell, Jerker C
2015-07-01
Existing explanations of reference-dependent risk sensitivity attribute it to cognitive imperfections and heuristic choice processes. This article shows that behavior consistent with an S-shaped value function could be an implication of rational inferences about the expected values of alternatives. Theoretically, I demonstrate that even a risk-neutral Bayesian decision maker, who is uncertain about the reliability of observations, should use variability in observed outcomes as a predictor of low expected value for outcomes above a reference level, and as a predictor of high expected value for outcomes below a reference level. Empirically, I show that combining past outcomes using an S-shaped value function leads to accurate predictions about future values. The theory also offers a rationale for why risk sensitivity consistent with an inverse S-shaped value function should occur in experiments on decisions from experience with binary payoff distributions. (c) 2015 APA, all rights reserved).
NASA Technical Reports Server (NTRS)
Miller, Richard L.; Belz, Mathias; DelCastillo, Carlos; Trzaska, Rick
2001-01-01
We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, aCDOM, and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values and showed a linear response across all four pathlengths. Values of aCDOM measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of aCDOM for MPLCW measurements was 0.002 - 231.5 m-1. At low CDOM concentrations spectrophotometric aCDOM were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples.
Levitt, Naomi S; Puoane, Thandi; Denman, Catalina A; Abrahams-Gessel, Shafika; Surka, Sam; Mendoza, Carlos; Khanam, Masuma; Alam, Sartaj; Gaziano, Thomas A
2015-01-01
We have found that community health workers (CHWs) with appropriate training are able to accurately identify people at high cardiovascular disease (CVD) risk in the community who would benefit from the introduction of preventative management, in Bangladesh, Guatemala, Mexico, and South Africa. This paper examines the attendance pattern for those individuals who were so identified and referred to a health care facility for further assessment and management. Patient records from the health centres in each site were reviewed for data on diagnoses made and treatment commenced. Reasons for non-attendance were sought from participants who had not attended after being referred. Qualitative data were collected from study coordinators regarding their experiences in obtaining the records and conducting the record reviews. The perspectives of CHWs and community members, who were screened, were also obtained. Thirty-seven percent (96/263) of those referred attended follow-up: 36 of 52 (69%) were urgent and 60 of 211 (28.4%) were non-urgent referrals. A diagnosis of hypertension (HTN) was made in 69% of urgent referrals and 37% of non-urgent referrals with treatment instituted in all cases. Reasons for non-attendance included limited self-perception of risk, associated costs, health system obstacles, and lack of trust in CHWs to conduct CVD risk assessments and to refer community members into the health system. The existing barriers to referral in the health care systems negatively impact the gains to be had through screening by training CHWs in the use of a simple risk assessment tool. The new diagnoses of HTN and commencement on treatment in those that attended referrals underscores the value of having persons at the highest risk identified in the community setting and referred to a clinic for further evaluation and treatment.
Buzayan, Muaiyed; Baig, Mirza Rustum; Yunus, Norsiah
2013-01-01
This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. A reference model with six internal-connection implant replicas placed in the completely edentulous mandibular arch and connected to multi-base abutments was fabricated from heat-curing acrylic resin. Forty impressions of the reference model were made, 20 each with polyether (PE) and polyvinylsiloxane (PVS) impression materials using the open tray technique. The PE and PVS groups were further subdivided into four subgroups of five each on the bases of splinting type: no splinting, bite registration PE, bite registration addition silicone, or autopolymerizing acrylic resin. The positional accuracy of the implant replica heads was measured on the poured casts using a coordinate measuring machine to assess linear differences in interimplant distances in all three axes. The collected data (linear and three-dimensional [3D] displacement values) were compared with the measurements calculated on the reference resin model and analyzed with nonparametric tests (Kruskal-Wallis and Mann-Whitney). No significant differences were found between the various splinting groups for both PE and PVS impression materials in terms of linear and 3D distortions. However, small but significant differences were found between the two impression materials (PVS, 91 μm; PE, 103 μm) in terms of 3D discrepancies, irrespective of the splinting technique employed. Casts obtained from both impression materials exhibited differences from the reference model. The impression material influenced impression inaccuracy more than the splinting material for multiple-unit abutment-level impressions.
Martínez-Búrdalo, M; Martín, A; Anguiano, M; Villar, R
2005-09-07
In this work, the procedures for safety assessment in the close proximity of cellular communications base-station antennas at three different frequencies (900, 1800 and 2170 MHz) are analysed. For each operating frequency, we have obtained and compared the distances to the antenna from the exposure places where electromagnetic fields are below reference levels and the distances where the specific absorption rate (SAR) values in an exposed person are below the basic restrictions, according to the European safety guidelines. A high-resolution human body model has been located, in front of each base-station antenna as a worst case, at different distances, to compute whole body averaged SAR and maximum 10 g averaged SAR inside the exposed body. The finite-difference time-domain method has been used for both electromagnetic fields and SAR calculations. This paper shows that, for antenna-body distances in the near zone of the antenna, the fact that averaged field values be below the reference levels could, at certain frequencies, not guarantee guidelines compliance based on basic restrictions.
Olmedo-Alguacil, Maria Milagrosa; Ramírez-Rodrigo, Jesús; Villaverde-Gutiérrez, Carmen; Sánchez-Caravaca, Maria Angeles; Aguilar Ferrándiz, Encarnación; Ruiz-Villaverde, Alberto
2016-11-01
Perceptions of health-related quality of life (HRQOL) are influenced by sociodemographic variables and by cultural-religious concepts of health, disease, and old age, among others. To assess the HRQOL of older people in a population with a long history of multiculturalism, the city of Ceuta (Spain), and to compare the results with Spanish reference values. A total of 372 individuals (55.4% females) were interviewed using the Spanish version of the Short Form-36 questionnaire. The subjects' mean age was 70.9 (SD = 5) years: 253 were Christians, 93 Muslims, and 26 Jews, representing the proportions in the overall population of these cultural-religious groups. HRQOL differs according to the cultural-religious affiliation, which specifically affects social and psychological dimensions. All groups obtained lower social function scores than the reference values, especially the Muslim and Jewish groups. Health care providers may consider integrating culturally sensitive interventions to improve HRQOL. © The Author(s) 2015.
Sorokin, Victoria; Alkhoury, Razan; Al-Rawabdeh, Sura; Houston, Ronald H; Thornton, David; Kerlin, Bryce; O'Brien, Sarah; Baker, Peter; Boesel, Carl; Uddin, Minhaj; Yin, Han; Kahwash, Samir
This study sought to determine delta granule normal ranges for children and to validate methodology for the appropriate diagnosis of delta granule deficiency (storage pool disease) by using the whole-mount technique in electron microscopy. Specimens obtained from 40 healthy volunteers (2 months of age through 21 years old, 21 females and 19 males) were tested. Results showed dense granules/platelet (DG/Plt) ranged from 1.78 to 5.25. The 5th percentile was 1.96 DG/Plt with an overall mean ± SEM 3.07 ± 0.12 DG/Plt. In comparison, a previously published lower cutoff value, 3.68 DG/Plt, was significantly higher than the mean from our volunteers (P < 0.0001). We found no variability in dense granules/platelet based on race or sex and no significant variation by age subgroup. Pending wider studies, the value of 2 DG/Plt is a more appropriate lower limit of normal. In the absence of wider studies (in healthy volunteers and patients), laboratories should consider establishing their own reference ranges.
Chemical guide parameters for Spanish lemon (Citrus limon (L.) Burm.) juices.
Lorente, José; Vegara, Salud; Martí, Nuria; Ibarz, Albert; Coll, Luís; Hernández, Julio; Valero, Manuel; Saura, Domingo
2014-11-01
To contribute for setting reference guideline for commercial juice extracted from the Spanish lemon varieties, chemical composition of 92 direct and 92 reconstituted samples were investigated. In direct lemon juice, titratable acidity was 52.4 g/L, being the citric acid the main component. Glucose, fructose and sucrose concentrations were 7.9, 7.3 and 4.5 g/L, respectively. Predominant mineral was potassium (1264.2mg/L), followed by phosphorous (306 mg/L), calcium (112 mg/L) and magnesium (92.6 mg/L). Hesperidin ranged from 257 to 484.8 mg/L, while water soluble pectins varied between 164.8 and 550 mg/L. Similar values were obtained in reconstituted lemon juice. There are different parameters that did not reach or exceeded the limits proposed by the European Association of the Industry of Juices and Nectars. These levels should be taken into account to modify the present reference guideline and that Spanish lemon juices are not discarded for to have lower or bigger values. Copyright © 2014 Elsevier Ltd. All rights reserved.
Bayes’ theorem, the ROC diagram and reference values: Definition and use in clinical diagnosis
Kallner, Anders
2017-01-01
Medicine is diagnosis, treatment and care. To diagnose is to consider the probability of the cause of discomfort experienced by the patient. The physician may face many options and all decisions are liable to uncertainty to some extent. The rational action is to perform selected tests and thereby increase the pre-test probability to reach a superior post-test probability of a particular option. To draw the right conclusions from a test, certain background information about the performance of the test is necessary. We set up a partially artificial dataset with measured results obtained from the laboratory information system and simulated diagnosis attached. The dataset is used to explore the use of contingency tables with a unique graphic design and software to establish and compare ROC graphs. The loss of information in the ROC curve is compensated by a cumulative data analysis (CDA) plot linked to a display of the efficiency and predictive values. A standard for the contingency table is suggested and the use of dynamic reference intervals discussed. PMID:29209139
NASA Astrophysics Data System (ADS)
Kim, Chan Hyeong; Hyoun Choi, Sang; Jeong, Jong Hwi; Lee, Choonsik; Chung, Min Suk
2008-08-01
A Korean voxel model, named 'High-Definition Reference Korean-Man (HDRK-Man)', was constructed using high-resolution color photographic images that were obtained by serially sectioning the cadaver of a 33-year-old Korean adult male. The body height and weight, the skeletal mass and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The resulting model was then implemented into a Monte Carlo particle transport code, MCNPX, to calculate the dose conversion coefficients for the internal organs and tissues. The calculated values, overall, were reasonable in comparison with the values from other adult voxel models. HDRK-Man showed higher dose conversion coefficients than other models, due to the facts that HDRK-Man has a smaller torso and that the arms of HDRK-Man are shifted backward. The developed model is believed to adequately represent average Korean radiation workers and thus can be used for more accurate calculation of dose conversion coefficients for Korean radiation workers in the future.
Lucena, Rafael; Cárdenas, Soledad; Gallego, Mercedes; Valcárcel, Miguel
2006-03-01
Monitoring the exhaustion of alkaline degreasing baths is one of the main aspects in metal mechanizing industrial process control. The global level of surfactant, and mainly grease, can be used as ageing indicators. In this paper, an attenuated total reflection-Fourier transform infrared (ATR-FTIR) membrane-based sensor is presented for the determination of these parameters. The system is based on a micro-liquid-liquid extraction of the analytes through a polymeric membrane from the aqueous to the organic solvent layer which is in close contact with the internal reflection element and continuously monitored. Samples are automatically processed using a simple, robust sequential injection analysis (SIA) configuration, on-line coupled to the instrument. The global signal obtained for both families of compounds are processed via a multivariate calibration technique (partial least squares, PLS). Excellent correlation was obtained for the values given by the proposed method compared to those of the gravimetric reference one with very low error values for both calibration and validation.
NASA Astrophysics Data System (ADS)
Novitasari, Linda; Astya Agustina, Puput; Sukesti, Ria; Faizal Nazri, Muhammad; Handhika, Jeffry
2017-11-01
The purpose of this research is to explore the potential of ethnoscience and the value of local wisdom contained in the tradition of “sea alms” in Teleng Ria Pacitan Beach, to profile as a science literacy in junior high school. The qualitative descriptive method used, where the researcher conducts the study on group culture under natural conditions through observation, interview, and documentation. The profile obtained in a booklet and socialized in students of Junior High School (SMPN 3 Tegalombo and SMPN 1 Pacitan). From this activity obtained information that the ability of students in interpreting ethnoscience in the tradition of “alms sea” in scientific science knowledge increases. It can conclude that the ethnoscience profile and the value of local wisdom can be used as an alternative science literacy in junior high school and has the potential to be used as a reference provider of data related traditions “Sea alms” and its integration with scientific knowledge.
NASA Astrophysics Data System (ADS)
Vagh, Hardik A.; Baghai-Wadji, Alireza
2008-12-01
Current technological challenges in materials science and high-tech device industry require the solution of boundary value problems (BVPs) involving regions of various scales, e.g. multiple thin layers, fibre-reinforced composites, and nano/micro pores. In most cases straightforward application of standard variational techniques to BVPs of practical relevance necessarily leads to unsatisfactorily ill-conditioned analytical and/or numerical results. To remedy the computational challenges associated with sub-sectional heterogeneities various sophisticated homogenization techniques need to be employed. Homogenization refers to the systematic process of smoothing out the sub-structural heterogeneities, leading to the determination of effective constitutive coefficients. Ordinarily, homogenization involves a sophisticated averaging and asymptotic order analysis to obtain solutions. In the majority of the cases only zero-order terms are constructed due to the complexity of the processes involved. In this paper we propose a constructive scheme for obtaining homogenized solutions involving higher order terms, and thus, guaranteeing higher accuracy and greater robustness of the numerical results. We present
Monitoring the fetal heart rate variability during labor.
Moslem, B; Mohydeen, A; Bazzi, O
2015-08-01
In respect to the main goal of our ongoing work for estimating the heart rate variability (HRV) from fetal electrocardiogram (FECG) signals for monitoring the health of the fetus, we investigate in this paper the possibility of extracting the fetal heart rate variability (HRV) directly from the abdominal composite recordings. Our proposed approach is based on a combination of two techniques: Periodic Component Analysis (PiCA) and recursive least square (RLS) adaptive filtering. The Fetal HRV of the estimated FECG signal is compared to a reference value extracted from an FECG signal recorded by using a spiral electrode attached directly to the fetal scalp. The results obtained show that the fetal HRV can be directly evaluated from the abdominal composite recordings without the need of recording an external reference signal.
On-line calibration of high-response pressure transducers during jet-engine testing
NASA Technical Reports Server (NTRS)
Armentrout, E. C.
1974-01-01
Jet engine testing is reported concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero-shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique no leak matrix valve design is used in the reference pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.
Ultralong time response of magnetic fluid based on fiber-optic evanescent field.
Du, Bobo; Yang, Dexing; Bai, Yang; Yuan, Yuan; Xu, Jian; Jiang, Yajun; Wang, Meirong
2016-07-20
The ultralong time (a few hours) response properties of magnetic fluid using etched optical fiber are visualized and investigated experimentally. The operating structure is made by injecting magnetic fluid into a capillary tube that contains etched single-mode fiber. An interesting extreme asymmetry is observed, in which the transmitted light intensity after the etched optical fiber cannot reach the final steady value when the external magnetic field is turned on (referred to as the falling process), while it can reach the stable state quickly once the magnetic field is turned off (referred to as the rising process). The relationship between the response times/loss rates of the transmitted light and the strength of the applied magnetic field is obtained. The physical mechanisms of two different processes are discussed qualitatively.
Optimal four-impulse rendezvous between coplanar elliptical orbits
NASA Astrophysics Data System (ADS)
Wang, JianXia; Baoyin, HeXi; Li, JunFeng; Sun, FuChun
2011-04-01
Rendezvous in circular or near circular orbits has been investigated in great detail, while rendezvous in arbitrary eccentricity elliptical orbits is not sufficiently explored. Among the various optimization methods proposed for fuel optimal orbital rendezvous, Lawden's primer vector theory is favored by many researchers with its clear physical concept and simplicity in solution. Prussing has applied the primer vector optimization theory to minimum-fuel, multiple-impulse, time-fixed orbital rendezvous in a near circular orbit and achieved great success. Extending Prussing's work, this paper will employ the primer vector theory to study trajectory optimization problems of arbitrary eccentricity elliptical orbit rendezvous. Based on linearized equations of relative motion on elliptical reference orbit (referred to as T-H equations), the primer vector theory is used to deal with time-fixed multiple-impulse optimal rendezvous between two coplanar, coaxial elliptical orbits with arbitrary large eccentricity. A parameter adjustment method is developed for the prime vector to satisfy the Lawden's necessary condition for the optimal solution. Finally, the optimal multiple-impulse rendezvous solution including the time, direction and magnitudes of the impulse is obtained by solving the two-point boundary value problem. The rendezvous error of the linearized equation is also analyzed. The simulation results confirmed the analyzed results that the rendezvous error is small for the small eccentricity case and is large for the higher eccentricity. For better rendezvous accuracy of high eccentricity orbits, a combined method of multiplier penalty function with the simplex search method is used for local optimization. The simplex search method is sensitive to the initial values of optimization variables, but the simulation results show that initial values with the primer vector theory, and the local optimization algorithm can improve the rendezvous accuracy effectively with fast convergence, because the optimal results obtained by the primer vector theory are already very close to the actual optimal solution. If the initial values are taken randomly, it is difficult to converge to the optimal solution.
FFT swept filtering: a bias-free method for processing fringe signals in absolute gravimeters
NASA Astrophysics Data System (ADS)
Křen, Petr; Pálinkáš, Vojtech; Mašika, Pavel; Val'ko, Miloš
2018-05-01
Absolute gravimeters, based on laser interferometry, are widely used for many applications in geoscience and metrology. Although currently the most accurate FG5 and FG5X gravimeters declare standard uncertainties at the level of 2-3 μGal, their inherent systematic errors affect the gravity reference determined by international key comparisons based predominately on the use of FG5-type instruments. The measurement results for FG5-215 and FG5X-251 clearly showed that the measured g-values depend on the size of the fringe signal and that this effect might be approximated by a linear regression with a slope of up to 0.030 μGal/mV . However, these empirical results do not enable one to identify the source of the effect or to determine a reasonable reference fringe level for correcting g-values in an absolute sense. Therefore, both gravimeters were equipped with new measuring systems (according to Křen et al. in Metrologia 53:27-40, 2016. https://doi.org/10.1088/0026-1394/53/1/27 applied for FG5), running in parallel with the original systems. The new systems use an analogue-to-digital converter HS5 to digitize the fringe signal and a new method of fringe signal analysis based on FFT swept bandpass filtering. We demonstrate that the source of the fringe size effect is connected to a distortion of the fringe signal due to the electronic components used in the FG5(X) gravimeters. To obtain a bias-free g-value, the FFT swept method should be applied for the determination of zero-crossings. A comparison of g-values obtained from the new and the original systems clearly shows that the original system might be biased by approximately 3-5 μGal due to improperly distorted fringe signal processing.
Dual energy micro CT SkyScan 1173 for the characterization of urinary stone
NASA Astrophysics Data System (ADS)
Fitri, L. A.; Asyana, V.; Ridwan, T.; Anwary, F.; Soekersi, H.; Latief, F. D. E.; Haryanto, F.
2016-03-01
Knowledge of the composition of urinary stones is an essential part to determine suitable treatments for patients. The aim of this research is to characterize the urinary stones by using dual energy micro CT SkyScan 11173. This technique combines high-energy and low- energy scanning during a single acquisition. Six human urinary stones were scanned in vitro using 80 kV and 120 kV micro CT SkyScan 1173. Projected images were produced by micro CT SkyScan 1173 and then reconstructed using NRecon (in-house software from SkyScan) to obtain a complete 3D image. The urinary stone images were analysed using CT analyser to obtain information of internal structure and Hounsfield Unit (HU) values to determine the information regarding the composition of the urinary stones, respectively. HU values obtained from some regions of interest in the same slice are compared to a reference HU. The analysis shows information of the composition of the six scanned stones obtained. The six stones consist of stone number 1 (calcium+cystine), number 2 (calcium+struvite), number 3 (calcium+cystine+struvite), number 4 (calcium), number 5 (calcium+cystine+struvite), and number 6 (calcium+uric acid). This shows that dual energy micro CT SkyScan 1173 was able to characterize the composition of the urinary stone.
On the unification of geodetic leveling datums using satellite altimetry
NASA Technical Reports Server (NTRS)
Mather, R. S.; Rizos, C.; Morrison, T.
1978-01-01
Techniques are described for determining the height of Mean Sea Level (MSL) at coastal sites from satellite altimetry. Such information is of value in the adjustment of continental leveling networks. Numerical results are obtained from the 1977 GEOS-3 altimetry data bank at Goddard Space Flight Center using the Bermuda calibration of the altimeter. Estimates are made of the heights of MSL at the leveling datums for Australia and a hypothetical Galveston datum for central North America. The results obtained are in reasonable agreement with oceanographic estimates obtained by extrapolation. It is concluded that all gravity data in the Australian bank AUSGAD 76 and in the Rapp data file for central North America refer to the GEOS-3 altimeter geoid for 1976.0 with uncertainties which do not exceed + or - 0.1 mGal.
Improvements in world-wide intercomparison of PV module calibration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salis, E.; Pavanello, D.; Field, M.
The calibration of the electrical performance of seven photovoltaic (PV) modules was compared between four reference laboratories on three continents. The devices included two samples in standard and two in high-efficiency crystalline silicon technology, two CI(G)S and one CdTe module. The reference value for each PV module parameter was calculated from the average of the results of all four laboratories, weighted by the respective measurement uncertainties. All single results were then analysed with respect to this reference value using the E n number approach. For the four modules in crystalline silicon technology, the results agreed in general within +/-0.5%, withmore » all values within +/-1% and all E n numbers well within [-1, 1], indicating further scope for reducing quoted measurement uncertainty. Regarding the three thin-film modules, deviations were on average roughly twice as large, i.e. in general from +/-1% to +/-2%. A number of inconsistent results were observable, although within the 5% that can be statistically expected on the basis of the E n number approach. Most inconsistencies can be traced to the preconditioning procedure of one participant, although contribution of other factors cannot be ruled out. After removing these obvious inconsistent results, only two real outliers remained, representing less than 2% of the total number of measurands. The results presented show improved agreement for the calibration of PV modules with respect to previous international exercises. For thin-film PV modules, the preconditioning of the devices prior to calibration measurements is the most critical factor for obtaining consistent results, while the measurement processes seem consistent and repeatable.« less
Improvements in world-wide intercomparison of PV module calibration
Salis, E.; Pavanello, D.; Field, M.; ...
2017-09-14
The calibration of the electrical performance of seven photovoltaic (PV) modules was compared between four reference laboratories on three continents. The devices included two samples in standard and two in high-efficiency crystalline silicon technology, two CI(G)S and one CdTe module. The reference value for each PV module parameter was calculated from the average of the results of all four laboratories, weighted by the respective measurement uncertainties. All single results were then analysed with respect to this reference value using the E n number approach. For the four modules in crystalline silicon technology, the results agreed in general within +/-0.5%, withmore » all values within +/-1% and all E n numbers well within [-1, 1], indicating further scope for reducing quoted measurement uncertainty. Regarding the three thin-film modules, deviations were on average roughly twice as large, i.e. in general from +/-1% to +/-2%. A number of inconsistent results were observable, although within the 5% that can be statistically expected on the basis of the E n number approach. Most inconsistencies can be traced to the preconditioning procedure of one participant, although contribution of other factors cannot be ruled out. After removing these obvious inconsistent results, only two real outliers remained, representing less than 2% of the total number of measurands. The results presented show improved agreement for the calibration of PV modules with respect to previous international exercises. For thin-film PV modules, the preconditioning of the devices prior to calibration measurements is the most critical factor for obtaining consistent results, while the measurement processes seem consistent and repeatable.« less
Phommasone, Koukeo; Althaus, Thomas; Souvanthong, Phonesavanh; Phakhounthong, Khansoudaphone; Soyvienvong, Laxoy; Malapheth, Phatthaphone; Mayxay, Mayfong; Pavlicek, Rebecca L; Paris, Daniel H; Dance, David; Newton, Paul; Lubell, Yoel
2016-02-04
C-Reactive Protein (CRP) has been shown to be an accurate biomarker for discriminating bacterial from viral infections in febrile patients in Southeast Asia. Here we investigate the accuracy of existing rapid qualitative and semi-quantitative tests as compared with a quantitative reference test to assess their potential for use in remote tropical settings. Blood samples were obtained from consecutive patients recruited to a prospective fever study at three sites in rural Laos. At each site, one of three rapid qualitative or semi-quantitative tests was performed, as well as a corresponding quantitative NycoCard Reader II as a reference test. We estimate the sensitivity and specificity of the three tests against a threshold of 10 mg/L and kappa values for the agreement of the two semi-quantitative tests with the results of the reference test. All three tests showed high sensitivity, specificity and kappa values as compared with the NycoCard Reader II. With a threshold of 10 mg/L the sensitivity of the tests ranged from 87-98 % and the specificity from 91-98 %. The weighted kappa values for the semi-quantitative tests were 0.7 and 0.8. The use of CRP rapid tests could offer an inexpensive and effective approach to improve the targeting of antibiotics in remote settings where health facilities are basic and laboratories are absent. This study demonstrates that accurate CRP rapid tests are commercially available; evaluations of their clinical impact and cost-effectiveness at point of care is warranted.
Nuzzo, James L
2015-02-01
The primary purpose of this study was to identify the most appropriate method for normalizing physical performance measures to body mass in American football players. Data were obtained from the population of players (n = 4,603) that completed the vertical jump, broad jump, 40-yd sprint, 20-yd shuttle, 3-cone drill, and bench press at the National Football League Scouting Combine from 1999 to 2014. Correlation coefficients were used to assess relationships between body mass and physical performance measures. For the entire group and each playing position, absolute (i.e., non-normalized) performance measures were significantly (p ≤ 0.05) correlated with body mass, indicating that normalization is warranted. Ratio scaling, however, was not appropriate for normalizing most performance measures because it merely reversed (and increased in magnitude) the significant correlations between body mass and performance. Allometric scaling with derived allometric parameters was appropriate for normalizing all performance measures because correlations between body mass and performance were near to zero and no longer statistically significant. However, the derived allometric parameters differed by playing position. Thus, when normalizing physical performance measures to body mass, strength and conditioning professionals should use allometric scaling with test- and position-specific allometric parameters. Additionally, in the current study, percentile rankings were generated to provide test- and position-specific normative reference values for the absolute measures. Until body mass normalization techniques are adopted more broadly, strength and conditioning professionals can use these normative references values to compare current players with those who have already participated in the Scouting Combine.
A new sensitive automated assay for procalcitonin detection: LIAISON® BRAHMS PCT® II GEN.
Fortunato, Antonio
2016-12-01
To assess the performance of LIAISON ® BRAHMS PCT ® II GEN (DiaSorin, Saluggia, Italy) in procalcitonin (PCT) determination by comparing it to the assay reference method B·R·A·H·M·S PCT KRYPTOR (Thermo Fisher Scientific Clinical Diagnostics, Hennigsdorf, Germany) and assessing its ability to discriminate between healthy subjects and patients with suspected infection. Diagnostic performance was evaluated on: a) 193 selected samples covering the assay range, whose procalcitonin levels were already evaluated with the B·R·A·H·M·S PCT ® KRYPTOR; b) prospective samples: 150 apparently healthy specimens obtained from a blood bank, 161 hospitalized patients (not with specific pathologies), 243 apparently healthy children. The comparison of LIAISON ® BRAHMS PCT ® II GEN to the reference method B·R·A·H·M·S PCT KRYPTOR yielded high correlation coefficients: slope of Deming fit equal to 1.04 (95% CI: 0.99-1.09) with an intercept equal to 0.05 (95% CI: -0.09 to 0.19) and a high concordance (98.4% (95% CI: 95.5-99.7%)) at the 0.5 ng/mL cut-off. Moreover, the results obtained using prospective samples showed: (i) no samples with PCT concentration >0.5 ng/mL (cut-off) for the apparently healthy adults (highest value=0.033 ng/mL, 95th percentile and 97.5th percentile <0.02 ng/mL); (ii) 2 samples >0.5 ng/mL for hospitalized patients (highest value=0.715 ng/mL, 95th percentile: 0.054 ng/mL; 97.5th percentile: 0.088 ng/mL); (iii) 3 samples >0.5 ng/mL for the healthy children population (highest value=0.713 ng/mL, 95th percentile: 0.155 ng/mL; 97.5th percentile: 0.275 ng/mL). The fully automated LIAISON ® BRAHMS PCT ® II GEN agrees well with the reference method and is suitable for early diagnosis of sepsis, severe bacterial infection and guiding antibiotic therapy.
Siqueira, José F; Rôças, Isabela N; De Uzeda, Milton; Colombo, Ana P; Santos, Kátia R N
2002-12-01
Molecular methods have been used recently to investigate the bacteria encountered in human endodontic infections. The aim of the present study was to compare the ability of a 16S rDNA-based PCR assay and checkerboard DNA-DNA hybridisation in detecting Actinobacillus actinomycetemcomitans, Bacteroides forsythus, Peptostreptococcus micros, Porphyromonas endodontalis, Por. gingivalis and Treponema denticola directly from clinical samples. Specimens were obtained from 50 cases of endodontic infections and the presence of the target species was investigated by whole genomic DNA probes and checkerboard DNA-DNA hybridisation or taxon-specific oligonucleotides with PCR assay. Prevalence of the target species was based on data obtained by each method. The sensitivity and specificity of each molecular method was compared with the data generated by the other method as the reference--a value of 1.0 representing total agreement with the chosen standard. The methods were also compared with regard to the prevalence values for each target species. Regardless of the detection method used, T. denticola, Por. gingivalis, Por. endodontalis and B. forsythus were the most prevalent species. If the checkerboard data for these four species were used as the reference, PCR detection sensitivities ranged from 0.53 to 1.0, and specificities from 0.5 to 0.88, depending on the target bacterial species. When PCR data for the same species were used as the reference, the detection sensitivities for the checkerboard method ranged from 0.17 to 0.73, and specificities from 0.75 to 1.0. Accuracy values ranged from 0.6 to 0.74. On the whole, matching results between the two molecular methods ranged from 60% to 97.5%, depending on the target species. The major discrepancies between the methods comprised a number of PCR-positive but checkerboard-negative results. Significantly higher prevalence figures for Por. endodontalis and T. denticola were observed after PCR assessment. There was no further significant difference between the methods with regard to detection of the other target species.
Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2015-08-01
To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.
Lee, Kyung-Min; Uhm, Gi-Soo; Cho, Jin-Hyoung; McNamara, James A.
2013-01-01
Objective The purpose of this study was to evaluate the effectiveness of the use of Reference Ear Plug (REP) during cone-beam computed tomography (CBCT) scan for the generation of lateral cephalograms from CBCT scan data. Methods Two CBCT scans were obtained from 33 adults. One CBCT scan was acquired using conventional methods, and the other scan was acquired with the use of REP. Virtual lateral cephalograms created from each CBCT image were traced and compared with tracings of the real cephalograms obtained from the same subject. Results CBCT scan with REP resulted in a smaller discrepancy between real and virtual cephalograms. In comparing the real and virtual cephalograms, no measurements significantly differed from real cephalogram values in case of CBCT scan with REP, whereas many measurements significantly differed in the case of CBCT scan without REP. Conclusion Measurements from CBCT-generated cephalograms are more similar to those from real cephalograms when REP are used during CBCT scan. Thus, the use of REP is suggested during CBCT scan to generate accurate virtual cephalograms from CBCT scan data. PMID:23671830
A novel and eco-friendly analytical method for phosphorus and sulfur determination in animal feed.
Novo, Diogo L R; Pereira, Rodrigo M; Costa, Vanize C; Hartwig, Carla A; Mesko, Marcia F
2018-04-25
An eco-friendly method for indirect determining phosphorus and sulfur in animal feed by ion chromatography was proposed. Using this method, it was possible to digest 500 mg of animal feed in a microwave system under oxygen pressure (20 bar) using only a diluted acid solution (2 mol L -1 HNO 3 ). The accuracy of the proposed method was evaluated by recovery tests, by analysis of reference material (RM) and by comparison of the results with those obtained using conventional microwave-assisted digestion. Moreover, P results were compared with those obtained from the method recommended by AOAC International for animal feed (Method nr. 965.17) and no significant differences were found between the results. Recoveries for P and S were between 94 and 97%, and agreements with the reference values of RM were better than 94%. Phosphorus and S concentrations in animal feeds ranged from 10,026 to 28,357 mg kg -1 and 2259 to 4601 mg kg -1 , respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Studying the Relation of Postprandial Triglyceride with Coronary Artery Disease (CAD).
Manochehri, Mohammad; Moghadam, Adel Johari
2016-07-27
Coronary artery disease (CAD) is the most common cause of mortality worldwide and determination of contributing factors is essential. This study was conducted to study the relation of postprandial triglyceride as a risk of coronary artery disease in patients with proven CAD by angiography, referred to 502 Hospital of Army in 2015. This observational study conducted as a case-control and contained 80 male participants referred to 502 Hospital of Army. Half of these participants had proven CAD by angiography test and the other ones were healthy as a control group. Fasting serum triglyceride was evaluated in all participants and postprandial TG was checked 4 hours after a standard meal. Obtained data were analyzed by SPSS ver. 13. The results indicated that fasting TG and postprandial TG level were significantly higher in CAD patients (P-value=0.001). It was also shown evaluation of postprandial TG is more sensitive test than fasting TG in case of CAD patients. Our obtained results shown, evaluation of high level of postprandial TG is more reliable than fasting TG for patients whom suffer from CAD.
Chen, Zhihao; Yang, Xiufeng; Teo, Ju Teng; Ng, Soon Huat
2013-01-01
A new all optical method for long term and continuous blood pressure measurement and monitoring without using cuffs is proposed by using Ballistocardiography (BCG) and Photoplethysmograph (PPG). Based on BCG signal and PPG signal, a time delay between these two signals is obtained to calculate both systolic blood pressure and diastolic blood pressure via linear regression analysis. The fabricated noninvasive blood pressure monitoring device consists of a fiber sensor mat to measure BCG signal and a SpO2 sensor to measure PPG signal. A commercial digital oscillometric blood pressure meter is used to obtain reference values and for calibration. It has been found that by comparing with the reference device, our prototype has typical means and standard deviations of 9+/-5.6 mmHg for systolic blood pressure, 1.8+/-1.3 mmHg for diastolic blood pressure and 0.6+/-0.9 bpm for pulse rate, respectively. If the fiber optic SpO2 probe is used, this new all fiber cuffless noninvasive blood pressure monitoring device will truly be a MRI safe blood pressure measurement and monitoring device.
Merchán Arenas, Diego R.; Acevedo, Amner Muñoz; Vargas Méndez, Leonor Y.; Kouznetsov, Vladimir V.
2011-01-01
The essential oil (EO) of clove bud dried fruits from Eugenia caryophyllus was obtained by a conventional hydrodistillation process in an excellent yield (11.7 %). Its chemical composition was analyzed by GC-MS, identifying eugenol as a main constituent (60.5%). Four eugenol-like molecules, γ-diisoeugenol, hydroxymethyleugenol, dihydroeugenol and 1,3-dioxanylphenol, were synthesized using eugenol or isoeugenol as initial precursors under green chemistry protocols. To evaluate the possible antioxidant capacity of eugenol compounds including the clove bud EO, the Trolox® Equivalent Antioxidant Capacity value, obtained by the ABTS+• radical-cation discoloration method, was employed. The methodology was performed in a UV-Vis reader of 96-well microplates (dilution methodology), using well-known antioxidant agents (BHA, BHT and vitamin E) as reference compounds. It was found that the prepared eugenol derivatives had a more potent free radical scavenger activity than the reference compounds. In particular, the most active molecules, γ-diisoeugenol and 1,3-dioxanylphenol, were ca. 3-fold more potent than vitamin E. PMID:22145105
Merchán Arenas, Diego R; Acevedo, Amner Muñoz; Vargas Méndez, Leonor Y; Kouznetsov, Vladimir V
2011-01-01
The essential oil (EO) of clove bud dried fruits from Eugenia caryophyllus was obtained by a conventional hydrodistillation process in an excellent yield (11.7 %). Its chemical composition was analyzed by GC-MS, identifying eugenol as a main constituent (60.5%). Four eugenol-like molecules, γ-diisoeugenol, hydroxymethyleugenol, dihydroeugenol and 1,3-dioxanylphenol, were synthesized using eugenol or isoeugenol as initial precursors under green chemistry protocols. To evaluate the possible antioxidant capacity of eugenol compounds including the clove bud EO, the Trolox® Equivalent Antioxidant Capacity value, obtained by the ABTS(+•) radical-cation discoloration method, was employed. The methodology was performed in a UV-Vis reader of 96-well microplates (dilution methodology), using well-known antioxidant agents (BHA, BHT and vitamin E) as reference compounds. It was found that the prepared eugenol derivatives had a more potent free radical scavenger activity than the reference compounds. In particular, the most active molecules, γ-diisoeugenol and 1,3-dioxanylphenol, were ca. 3-fold more potent than vitamin E.